CNL-14-006, Response to NRC Request for Additional Information Regarding License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants for Browns Ferry Plant, Units 1, 2
| ML14077A201 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry |
| Issue date: | 01/14/2014 |
| From: | James Shea Tennessee Valley Authority |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML14077A199 | List: |
| References | |
| CNL-14-006, TAC MF1185, TAC MF1186, TAC MF1187 | |
| Download: ML14077A201 (69) | |
Text
L44 140114 001 Security-Related Information - Withhold from Public Disclosure in accordance with 10 CFR 2.390. Portions of Enclosure 1 contain Security-Related Information. Upon removal of Attachment 1 from Enclosure 1, this letter is uncontrolled.
Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 CNL-14-006 January 14, 2014 10 CFR 50.90 10 CFR 2.390 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296
Subject:
Response to NRC Request for Additional Information Regarding the License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants for the Browns Ferry Nuclear Plant, Units 1, 2, and 3 (TAC Nos. MF1185, MF1186, and MF1187)-Set 3
References:
- 1. Letter from TVA to NRC, "License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition) (Technical Specification Change TS-480)," dated March 27, 2013 (ADAMS Accession No. ML13092A393)
Printed on recycled paper
- 2. Letter from TVA to NRC, "Response to NRC Request to Supplement License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants for the Browns Ferry Nuclear Plant, Units 1, 2, and 3 (TAC Nos. MF1185, MF1186, and MF1187)," dated May 16, 2013 (ADAMS Accession No. ML13141A291)
- 3. Letter from NRC to TVA, "Browns Ferry Nuclear Plant, Units 1, 2, and 3 -
Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association Standard 805 Performance-Based Standard for Fire Protection for Light Water Reactor Generating Plants (TAC Nos. MF1185, MF1186, and MF1187)," dated November 19, 2013 (ADAMS Accession No. ML13298A702)
U.S. Nuclear Regulatory Commission Page 2 January 14, 2014 By letter dated March 27, 2013 (Reference 1 ), Tennessee Valley Authority (TVA) submitted a license amendment request (LAR) for Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3, to transition to National Fire Protection Association Standard (NFPA) 805. In addition, by letter dated May 16, 2013 (Reference 2), TVA provided information to supplement the Reference 1 letter.
By letter dated November 19, 2013 (Reference 3), the Nuclear Regulatory Commission (NRC) requested additional information to support the review of the LAR. The required dates for responding to the requests for additional information varied from a nominal 60 days to 120 days. provides the third set of TVA responses to some of the requests for additional information (RAls) identified in the Reference 3 letter. This enclosure provides the remainder of the nominal 60 day responses that were not previously submitted, with the exception of the responses whose due dates were extended to March 15, 2014 as documented in an electronic mail from the NRC to TVA, dated January 9, 2014. These nominal 60 day responses are due by January 14, 2014. In addition, Attachment 1 to includes markups of the LAR pages that are affected by the TVA response to FPE RAl-08. These LAR changes cannot be easily described in the response; therefore markup pages are provided. Furthermore, Attachment 1 to Enclosure 1 contains security-related information and should be withheld from public disclosure under 1 O CFR 2.390. Enclosure 2 provides a listing of all RAls listed in the Reference 3 letter and the actual date of the TVA response to each of the RAls.
Consistent with the standards set forth in Title 10 of the Code of Federal regulations (10 CFR), Part 50.92(c), TVA has determined that the additional information, as provided in this letter, does not affect the no significant hazards consideration associated with the proposed application previously provided in Reference 1.
There are no regulatory commitments contained in this submittal. Please address any questions regarding this submittal to Mr. Edward D. Schrull at (423) 751-3850.
I declare under penalty of perjury that the foregoing is true and correct. Executed on this 14th day of January 2014.
ice President, Nuclear Licensing
Enclosures:
- 1. TVA Responses to NRC Request for Additional Information: Set 3 (60-day)
U.S. Nuclear Regulatory Commission Page 3 January 14, 2014 cc(Enclosures):
NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant State Health Officer, Alabama State Department of Health
ENCLOSURE 1 Tennessee Valley Authority Browns Ferry Nuclear Plant, Units 1, 2, and 3 TVA Responses to NRC Request for Additional Information (RAI): Set 3 (60-day)
FPE RAI 08 The residual heat removal (RHR) pump/heat exchanger rooms lack automatic suppression systems and it was noted that water curtain and draft stop were previously installed in these rooms to separate them from the rest of the fire area. The NRC granted an Appendix R exemption for the lack of suppression and on the LAR, this exemption is requested to be carried forward. Although this "water curtain" is addressed in LAR, Table C-2, the "draft stop" is not listed. It appears that the "draft stop" was part of the original exemption and should be carried over as a fire protection feature. Provide justification for this apparent discrepancy. Identify any other locations where "draft stops" are credited.
RESPONSE
TVA considered the draft stop to be part of the water curtain and therefore, did not include the draft stop as a separate item. By design, the water curtain will not work properly without the draft stop. The draft stops around openings help bank heat near the ceiling from a postulated fire and thereby allow the closely spaced automatic sprinklers to operate quickly forming a water curtain around the openings. To be consistent, License Amendment Request (LAR) Tables C-1 and C-2 will be updated to reflect draft stops as well as water curtains. The markup of the appropriate LAR Tables C-1 and C-2 pages are included in Attachment 1 of this enclosure.
The credited water curtains and draft stops associated with the RHR exemptions are located in Fire Areas (FAs) 01-01, 01-02, 01-04, 02-01, 02-02, 02-04, 03-01, 03-02, 03-03. There are no other locations where water curtains and draft stops are credited to meet NFPA 805 requirements.
E1-1
FPE RAI 09 The NRC staff noted that special administrative controls will be in place to limit transient fires to 69 kilowatts (kW) in Fire Compartments 5, 9, 16A, 16K, 16M, and 16O. The fire hazards analysis describes combustibles in Fire Area 16 to be cable insulation, foam plastics, oil, lube oil, wood, paper, cloth, polyester and neoprene, charcoal, rubber, cellulose, styrofoam, and plywood. The assumption in LAR Attachment V,Section V.2.3, for 69 kW fires states that all fire compartments that were credited for a reduced heat release rate (HRR) will be subject to strict combustible controls (fire compartments designated as "No Combustible Storage") and paper, cardboard, scrap wood, rags and other trash shall not be allowed to accumulate in the area.
Provide a more detailed description of the control of combustibles. For Fire Compartment 16A (Main Control Room (MCR) for U1 and U2), provide details with regard to restricting the accumulation of paper, books, binders, trash, etc. Describe any special administrative controls that are expected to control transient fires to 69 kW, as opposed to the HRR (i.e., 317kW) in Table G-1 of NUREG/CR-6850 and Electric Power Research Institute (EPRI) 1011989, "EPRI/NRC-RES Fire PRA Methodology for Nuclear Power Facilities."
RESPONSE
LAR, Attachment S, Table S-3, Implementation Item 45 states that the administrative control procedure for transient combustibles will be revised to strengthen risk and defense in depth concepts (e.g., no storage and no hot work in designated areas). For fire compartments that were analyzed at the HRR of 69 kiloWatts (kW), strict transient combustible controls (i.e.,
designated as "Transient Combustible Free") will be put in place to restrict storage or staging of transient combustibles in these fire compartments. Combustible control procedures, training and other administrative measures (e.g., visual aids) will be put in place to ensure these controls are maintained.
Fire compartment 16A contains the Main Control Rooms (MCRs) and the Cable Spreading Rooms. The special administrative combustible controls apply to the Cable Spreading Rooms portion of fire compartment 16A. However, LAR Attachment V,Section V.2.3, incorrectly indicates that all of fire compartment 16A will have the special administrative controls. BFN Units 1, 2, and 3 Detailed Fire Modeling Report analyzed the Cable Spreading Rooms at the reduced HRR of 69 kW; the MCRs were analyzed utilizing an HRR of 317 kW. Therefore, the Cable Spreading Rooms will have the special combustible controls as indicated above but the MCRs will not be subjected to the stricter requirements.
LAR Attachment V,Section V.2.3, is revised in two areas.
Page V-4, last paragraph (which rolls over to Page V-5) is revised to state the following:
"The BFN Fire Probabilistic Risk Assessment (PRA) makes use of reduced HRRs in limited areas that are administratively controlled (See Implementation Item 45 in Table S-3 of Attachment S) to reduce the likelihood of large transient fires. Only six fire compartments modeled in the BFN Fire PRA have credited the transient controls to reduce the transient HRR to 60 kW (05, 09, 16-a (cable spreading rooms only), 16-K, 16-M, and 16-O)."
Page V-5, second paragraph is revised to state the following: "In the BFN Fire PRA, a 69 kW transient heat release rate was justified for certain fire compartments (05, 09, 16-A (cable spreading rooms only), 16-K, 16-M, and 16-O) based on several factors:" For both changes, the phrase "(cable spreading rooms only)" has been added after Fire Area 16-A to clarify that only the cable spreading rooms are applicable.
E1-2
SSA RAI 02 LAR Section 4.2.1.1 currently states that an open secondary circuit on a current transformer creates the need to perform an FRE for a secondary fire. The NRC staff noted that TVA calculations reviewed during the audit, indicate that open circuit secondary fires are possible.
VFDRs for open secondary circuits on current transformers are identified in LAR Attachment C, Table C-1. For a fire in the control room (Fire Area 16), VFDR 16-0243 indicates a potential open circuit secondary fire at "locations outside the control room," but resolves the VFDR by risk evaluation and no further action required. Provide more details regarding the following:
a) Explain the methodology used for CR abandonment, loss of control with alternate shutdown, or if operators remain in the CR to determine the risk contribution to the CR fire, and the justification for no further action required. Describe the safety margin and DID elements that Table B-3 indicates were satisfied.
b) Describe how the secondary fire was considered in this analysis.
c) Provide a list of locations for these secondary fires.
d) Provide a list of RAs for a fire in the CR required at any of the locations or panels susceptible to secondary fires.
e) Describe what components, if any, may be involved in the secondary fire, and are also required for an RA. Describe how this was accounted for in the risk analysis and the feasibility for RAs.
RESPONSE
Part a.
The analysis for secondary fires has been incorporated in the Fire PRA. The methodology utilized in the Fire PRA is the same irrespective of the fire scenario being MCR abandonment, loss of control with alternate shutdown, or if operators remain in the MCR. Targets affected by the secondary fire were added to the primary fire target set so that the primary fire includes both the targets in the room of fire origin, and the secondary fire targets.
The targets in the zone of influence of the secondary fires were included in the target set for the primary fire scenario/ignition source that could generate a secondary fire. In the case of fire scenarios in the MCR, the risk contribution (i.e., Core Damage Frequency (CDF) and Large Early Release Frequency (LERF)) from secondary fires outside the control room due to fires starting in the control room was accounted for in the calculation of the Conditional Core Damage Probability (CCDP) and Conditional Large Early Release Probability (CLERP) because the targets from the secondary fires (i.e., electrical cabinet, conduits and trays) were mapped to cables/basic events and set to fail (i.e., TRUE) in the quantification process for the corresponding control room fires. Recovery actions were also included in the logic model.
Credit for operator actions was determined considering the effects associated with the secondary fires.
The secondary fire locations are balance of plant non-safety related switchgear or generators located in the Turbine Building. The justification for no further action required is based on the delta risk calculation for the FA 16 meeting the performance criteria for CDF, LERF, delta CDF (CDF) and delta LERF (LERF).
Evaluations for Defense in Depth (DID) and Safety Margin (SM) were applied consistently to all the FAs within the scope of the NFPA 805 transition project. In the specific case of FA 16, the DID evaluation considered combustible and hot work controls, the benefits of automatic E1-3
detection and suppression systems, and the credit for a number of recovery actions due to fires in the area. The DID evaluation concluded that there was balance among the three DID echelons. Specifically:
Preventing fires from starting. Portions of FA 16 were designated as "no storage" and "special consideration hot work" to strengthen transient and hot work fire controls.
Rapidly detecting fires and controlling and extinguishing promptly those fires that do occur, thereby limiting damage. The fire detection system was required for DID in FA 16. Automatic suppression, portable extinguishers and hose stations were required for DID in FA 16.
Providing adequate level of fire protection for structures, systems and components important to safety, so that a fire that was not promptly extinguished did not prevent essential plant safety functions from being performed. The DID recovery actions are listed in LAR Attachment G.
The SM criteria required evaluation of the analytical techniques applied to ensure that there is margin to account for uncertainties. The evaluation considered the Fire PRA and the fire modeling analyses in support of the Fire PRA. The evaluation concluded that there was adequate margin in the analysis supporting FA 16 based on the methodologies followed for developing the analyses.
Part b.
NUREG/CR-7150, Volume 1 concluded that the likelihood of secondary fires from open circuit of higher ratio current transformers (CTs) (i.e., greater than 1200:5) to be very low, and recommended that additional testing be performed to confirm this judgment. In the absence of additional industry guidance on the likelihood of fire-induced open circuits and postulated secondary fire characteristics, TVA used a conservative approach for postulated secondary fires from the open circuit of higher ratio CTs in the NFPA 805 analysis. Consideration for secondary fires in the analysis consisted of the following steps:
- 1. Identification of the electrical cabinets housing the CTs.
- 2. Identification of the cables connecting to the CTs capable of generating the open circuit.
- 3. Identification of fire scenarios that could damage the cables identified in Step 2. These were the fires that could potentially generate a secondary fire at the electrical cabinet housing the CT (i.e., the cabinets identified in Step 1).
- 4. Identification of the targets (i.e., cable tray or conduits) within the zone of influence of the cabinets identified in Step 1. These were the targets that could be damaged by the secondary fires that are in addition to the electrical cabinet housing the CT. These targets were identified by walkdowns and drawing reviews. A zone of influence of 10 feet horizontally from the panels was utilized. Assuming a 1 MW fire, which is the largest heat release rate for cabinets listed in NUREG/CR-6850, Appendix G and using the point source flame radiation model, the thermoplastic damage criteria for heat flux is reached in approximately six feet. Therefore, the use of 10 feet is conservative.
Vertically, the zone of influence extends from the panel up to the ceiling of the room.
- 5. The targets identified in Step 4 were added to the fire scenarios identified in Step 3.
That is, the fire scenarios in Step 3 included an expanded target set to account for the effects of the secondary fires.
E1-4
Part c.
The locations of the CTs where secondary fires are postulated are listed in the table below.
Current Transformer Ignition Source ID Description Fire Compartment Room 0-BDAA-203-000A 4160V Common Board A 26-A 604-TB-1-West 0-BDAA-203-000B 4160V Common Board B 26-A TB 604' 0-BDAA-204-0001 4160V Unit Start Board 1 26-A 604-TB-1-West 0-BDAA-204-0002 4160V Unit Start Board 2 26-A 604-TB-1-West 1-BDAA-068-0001 4160V Recirculation Board 1 26-A TB 604' 1-BDAA-202-0001A 4160V Unit Board 1A 26-A 604-TB-1-West 1-BDAA-202-0001B 4106V Unit Board 1B 26-A 586-TB-1 1-BDAA-202-0001C 4160V Unit Board 1C 26-A 604-TB-1-West 2-BDAA-068-0002 4160V Recirculation Board 2 26-A TB 604' 2-BDAA-202-0002A 4160V Unit Board 2A 26-A TB 604' 2-BDAA-202-0002B 4160V Unit Board 2B 26-A TB 586' 2-BDAA-202-0002C 4160V Unit Board 2C 26-A TB 604' 3-BDAA-068-0003 4160V Recirculation Board 3 26-A 604.0-T-3 3-BDAA-202-0003A 4160V Unit Board 3A 26-A 604.0-T-3 3-BDAA-202-0003B 4160V Unit Board B3 26-A 586.0-T3 3-BDAA-202-0003C 4160V Unit Board 3C 26-A 604.0-T-3 Unit 1 Generator Unit 1 Generator 26-A TB 617 Unit 2 Generator Unit 2 Generator 26-A TB 617 Unit 3 Generator Unit 3 Generator 26-A TB 617 Part d.
There were no recovery actions taken at the panels susceptible to secondary fires.
There were two recovery actions that took place in the Turbine Building (i.e., FA 26) that had the potential to be affected from a secondary fire for a fire originating in FA 16. One FA 16 recovery action, performed in the Turbine Building, isolated control air to the reactor buildings to ensure that containment isolation valves fail closed. The second FA 16 recovery action operated the new Emergency High Pressure Makeup (EHPM) pump locally in the Turbine Building.
Part e.
No components that would be involved in the secondary fire at the CT locations listed in Part c of this RAI response were required to support a recovery action.
E1-5
The control air isolation is performed on Elevation (EL) 565 at the south end (near column m-line) of the Turbine Building. The locations for secondary fires were all located in the north end (column a-line to d-line) of the Turbine Building at EL 586 or above. Because the valves are at a lower elevation and have significant spatial separation, any secondary fires from open CTs would not adversely affect the feasibility of performing the control air isolation action.
The new EHPM pump is planned to be operated locally, when necessary, on EL 565 or below at the south end (near column g-line) of the Turbine Building at the pumps location. The locations for secondary fires were all located in the north end (column a-line to d-line) of the Turbine Building at EL 586 or above. Secondary fires that could fail the EHPM pump normal power supply are included in the Fire PRA model and inherently accounted for the secondary fire failure of the recovery action to operate the EHPM pump from the normal power supply. The EHPM pump alternate power supply and cabling will not be in the secondary fire zone of influence. Because the pump is at a lower elevation and has significant spatial separation, any secondary fires from open CTs would not adversely affect the feasibility of performing the pump operation action when the pump is available to be powered from normal or alternate power.
E1-6
SSA RAI 03 LAR Attachment C, Table C-1, identifies approximately 18 fire areas where VFDRs identify the potential of ignition of "secondary fires at locations outside" the fire area being analyzed. These are represented as "common enclosure" circuit issues. Provide more details regarding the following:
a) Explain the methodology used to determine the risk contribution to fire, and the justification for those with no further action required. Describe the safety margin and DID that Table B-3 indicates were satisfied.
b) Describe how the secondary fire was considered in the analysis.
c) Provide a list of locations for these secondary fires for each VFDR.
d) Provide a list of RAs for a fire in the CR required at any of the locations susceptible to secondary fires.
e) Describe what components, if any, may be involved in the secondary fire, and are also required for an RA. Describe how this was accounted for in the risk analysis and the feasibility for RAs.
RESPONSE
Electrically-induced secondary fires can potentially result from the failure of a circuit breaker to isolate an electrical fault caused by the initial fire. Larger circuit breakers require control power to operate, and fire events can cause breaker control power to be lost. Within a fire event time sequence, such a loss of control power may be early (e.g., the initial fire damages the cable providing control power to an electrical board) or late (e.g., the fire fails a battery charger or its power supply such that the available control power voltage degrades over time as the associated battery depletes). The details regarding potential secondary fires resulting from the special case of CT open circuits are discussed separately in the TVA response to Safe Shutdown Analysis (SSA) RAI 02 in this enclosure.
The BFN NFPA 805 transition strategy to address potential secondary fires is two-fold.
- 1) Any Variance from Deterministic Requirement (VFDR) related to early control power loss concurrent with the potential for an associated power cable fire-induced fault is being deterministically resolved by a plant modification such that the secondary fire initiation vulnerability is removed.
- 2) Regarding the late loss of control power situations, the VFDR risk was evaluated by the Fire PRA. The Fire PRA determined the risk was insignificant from potential secondary fires resulting from breaker control power loss due to battery depletion. This determination was based on the following failure probabilities and timing sequence relationship factors:
battery time-to-depletion analyses low probability of failure to restore a battery charger within the available battery depletion timeframes low probability of fire non-suppression within battery depletion time low probability of fires that fail battery chargers while also failing a target power cable of concern.
E1-7
Considering the factors cited in the four bullet points above for late control power loss situations, the initiation of a secondary fire would require the following events and human failure actions:
a) Loss of the control power battery charger soon after the onset of the fire. A delay in the charger loss would add to the length of time the board retained control power.
Delayed charger loss would allow greater time for breaker control power to function while the fire is being suppressed.
b) Inability of BFN fire operations personnel to suppress the fire to prevent further damage within the battery depletion time once the charger was lost.
c) Failure by BFN staff to transfer the board to an alternate control power supply or restore the associated charger to service prior to battery depletion.
d) Development of fire damage such that an associated power cable faults only after battery depletion.
e) Energizing the associated power cable (i.e., its breaker closed) when it is damaged.
The occurrence of the preceding set of events was judged to be so improbable as to be incredible, that plant risk was insignificant, and such potential secondary fires did not warrant further modeling in the Fire PRA. Because the occurrence of an electrically-induced secondary fire for late control power loss is considered incredible, no secondary fire locations exist, no components are involved in a secondary fire, and no recovery actions are impeded or affected by a secondary fire.
Evaluations for DID and SM were performed consistently for all of the FAs within the scope of the NFPA 805 transition project. The qualitative DID evaluation for the potential secondary fire initiation issues verified that appropriate balance existed between the three DID elements of:
- 1) fire prevention, 2) rapid fire detection, control, and extinguishment, and 3) providing adequate protection for plant essential safety systems against fire effects. DID recovery actions were established where necessary to improve this balance.
Regarding the potential for secondary fire initiation, the BFN NFPA 805 philosophy for establishing DID recovery actions for VFDRs related to late control power loss secondary fires was:
For VFDRs involving safety related electrical boards which might incur a late control power loss, DID recovery actions to restore battery chargers or transfer to an alternate control power source were established.
For VFDRs involving loss of non-safety related battery chargers, DID balance did not require the establishment of formal recovery actions for such low probability events.
While preparing the response to this RAI, TVA identified two instances where safety related board VFDRs involving a late loss of control power (i.e., VFDR 02-03-0026 and VFDR 16-0228) did not have an associated DID action, contrary to the BFN NFPA 805 DID philosophy stated above. These two instances were entered into the site corrective action program for resolution.
The revision to the LAR, reflecting the Fire Risk Evaluation update, will be provided to the NRC after the Fire Risk Evaluation is updated in response to the remaining NRC RAIs.
SM criteria require the evaluation of the analytical techniques applied to ensure that adequate margin exists to account for uncertainties. Regarding the potential secondary fire initiation issues, the SM evaluation considered the battery capacity analyses, the Fire PRA, and the fire modeling analyses which support the Fire PRA. The evaluation concluded adequate margin exists in these analyses and their methodologies.
E1-8
In summary, the loss-of-control power condition which results in a breakers inability to open under a fault condition was addressed in the BFN NFPA 805 transition by:
- 1) Ensuring that no early loss of direct current (DC) control power will occur for breakers protecting power cables that could be faulted in the same FA. Plant modifications were identified as appropriate to address the related VFDRs.
and by
- 2) The Fire PRA judging the risk to be insignificant from fire-induced faults which could occur only after battery depletion.
E1-9
SSA RAI 06 LAR Attachment S, Table S-2, Items 35 and 35a identify the proposed installation of a new emergency high pressure makeup pump for each unit. Provide a more detailed description of the proposed modification. Include in the description, equipment and systems that will be necessary to support the operation of this pump (electrical power, water supply, control valves, fuel oil supply, etc.). Describe the proposed operation of the pump including local and remote operations, and how is it intended to function during safe shutdown and/or alternate shutdown.
Describe the performance goals it would support. With regard to the current transformer analysis for secondary fires, include in this description the potential impact of secondary fires for the new pump power supplies.
RESPONSE
LAR Attachment S, Table S-2 Modification 35 proposes modifications to install a new EHPM pump for each unit capable of injecting water into the reactor vessel at high pressure. LAR Attachment S, Table S-2, Modification 35a proposes modifications that would provide the capability of supplying power to the EHPM pumps from new diesel generators (DGs) that are being installed as part of BFN Flexible and Diverse Coping Mitigation Strategies (FLEX)
Integrated Plan submitted to the NRC by letter dated February 28, 2013 (ADAMS Accession Number ML13064A465). Although the designs for these modifications are not finalized, the following discussions provide the current modification approach.
General Design Each unit will have a motor driven EHPM pump and associated valves and controls located in the Turbine Building. The EHPM system will normally be powered from offsite power sources, with alternate power available from new, non-safety related DGs. The EHPM pump will take suction from the Condensate Storage Tank (CST) for the respective unit and discharge to the reactor pressure vessel (RPV) via the feedwater lines. The system will be designed to control RPV inventory over a wide range of pressure from safety relief valve (SRV) setpoint (i.e., ~1150 psig) to zero pressure. The system will be capable of operation from a local control station in the turbine building. The option to control the system from the MCR is also under consideration.
Mechanical Design Each EHPM pump will take suction from the respective units CST and have access to the entire volume of the tank (i.e., below the standpipe), similar to the suction path for the High Pressure Coolant Injection (HPCI) and Reactor Core Isolation Cooling (RCIC) pumps. The pumps and piping will be located below the elevation of the CST such that piping is maintained filled by elevation head.
Each EHPM pump will discharge into the reactor feedwater lines downstream of the feedwater pumps, high pressure heaters and upstream of the feedwater check valves. Piping and valves will be provided to allow full flow return to the CST. Flow control valves will be provided to regulate flow to the RPV over a full range of flow and reactor pressure.
TVA anticipates that the bounding scenario for the hydraulic design of the EHPM pump will be to prevent core damage in the event of loss of all other makeup, up to one SRV spuriously opening and initiation of injection at 20 minutes after a reactor scram.
E1-10
Electrical Design The EHPM system will be provided with four kilovolts (kV) of power from the respective units 4kV Unit Board C, which in turn is supplied offsite power from the respective Unit Station Service Transformer (USST) or from the Common Station Service Transformer (CSST). Normal and alternate 4 kV power will be supplied to switchgear located near the pump, which will be used to distribute alternating current (AC) power to the system at required voltage levels.
DC control power will be supplied by batteries and battery chargers dedicated to each EHPM system.
Alternate 4 KV power will be supplied to the EHPM switchgear from new DGs being installed as part of the BFN FLEX Integrated Plan. Each EHPM pump will have a separate DG capable of supplying power required for operation of the system.
Instrumentation and Control The EHPM system will be designed with sufficient instrumentation and controls to start and stop the pump, monitor and control flow and discharge pressure, and to transfer power supplies.
Operation of the system will be manual.
Support Systems The EHPM system will be designed to minimize the need for external support systems. The only support currently planned from outside the new EHPM system is 4kV AC power from the AC power distribution system or the alternate supply DGs and water from the condensate storage system. Other typical support such as DC control power, pump and motor cooling, lighting, and heating, ventilation and air conditioning (HVAC) will be dedicated to the system.
Proposed Safe Shutdown Operation The EHPM pump is credited in the Fire PRA to inject water from the CST to the RPV within 20 minutes of the most limiting event to provide core cooling. This timing is related to operation of the pump from local controls in the turbine building. The system is also credited for longer term operation (i.e., four hours) to maintain RPV inventory and to remove decay heat when used in conjunction with the hardened wetwell vent. As discussed in the TVA response to SSA RAI 02 Part e in this enclosure, possible secondary CT fires which could fail the EHPM pump power supply are accounted for in the Fire PRA and the alternate power supply would not be affected.
E1-11
RAI SSA 09 For breaker fuse coordination, describe whether cable length was credited as additional impedance in the study necessary to meet maximum available fault current to demonstrate coordination with upstream power supply breakers. If this was used, describe how this length was factored into the potential impact to the FPRA. For establishing targets in the zone of influence (ZOI) describe how cable lengths were considered and provide any justifications required for the FPRA.
RESPONSE
In general, cable length is not credited to demonstrate adequate protective device coordination.
The plant has historically addressed coordination and protection concerns through device setting changes or breaker/fuse replacement. However, as documented in the BFN calculation entitled, "NFPA 805: Associated Circuit Analysis - Common Power Supply/Common Enclosure,"
cable impedance is considered in two specific cases to reduce maximum available fault current by a small amount in order to ensure no overlap in protective device trip characteristics. These two cases are described below as Case Number 1 and Case Number 2.
Case Number 1 - 250 Volts DC (VDC) Battery Boards 4, 5, and 6 Figure SSA-09.1 provides a simplified one-line diagram of 250 VDC Battery Boards 4, 5, and 6 and the power supplies to the boards. For these three boards, the load-side breakers and fuses must coordinate with the battery main breaker (i.e., 110) and fuse (i.e., 111). In a limited number of cases, the applicable coordination calculation credited probability-based arguments for justifying minor mis-coordination between Models THJK and AK-2-25 load-side breakers that did not coordinate with the battery fuse (i.e., Fuse 111) near the maximum theoretical available fault current.
The applicable coordination calculation did not explicitly credit cable length to reduce fault current but it did include in the qualitative argument for acceptability, consideration of the lower available fault current at locations more likely to experience a bolted fault at maximum fault current. The qualitative argument for adequacy was considered acceptable, even without any explicit consideration of load-side cable length external to the board because of the following:
For the non-vital 250 VDC system, cabling inside Battery Boards 4, 5, and 6 along with other system termination and contact resistance will likely reduce available fault current to levels that achieve full coordination.
Both the fuse and the breaker would need to be operating at the extreme limits of their time-current characteristics for a lack of coordination to exist.
DC system fault current calculations inherently include significant conservatism with respect to predicting maximum available fault current. This conservatism starts with assumed battery performance and continues throughout the sequential steps of modeling the remaining DC system configuration and attributes.
E1-12
5C (NC) 110 (NC) 250V BATTERY CHARGER 5 250V DC BATTERY BD 5 201 (NC)
~+
250VDC BATTERY 5 3D (NC) 110 (NC) 250V DC BATTERY BD 6 201 (NC)
~+
480V COMMON BD 3, BUS A 250VDC BATTERY 6 6D (NC) 3A (NO) 250V DC BATTERY BD 4 201 (NC) 480V SHUTDOWN BD 3B (NC)
(NO) 202 (NO) 202 (NO) 202 (NO) 110 (NC) 250V MAIN BATTERY 4 FUSE 111 480V COMMON BD 1, BUS A BATTERY CHARGER 4 INPUT TRANSFER SWITCH
~+
250V BATTERY CHARGER 4 SHUNT A
SHUNT A
SHUNT A
FUSE 201 OUTPUT TRANSFER SWITCH 2BA FUSE 111 OUTPUT TRANSFER SWITCH 2BA OUTPUT TRANSFER SWITCH 2BA FUSE 201 FUSE 201 250V BATTERY CHARGER 6 FUSE 111 480V COMMON BD 1, BUS A Figure SSA-09.1 250 VDC Battery Boards 4, 5, and 6 Case Number 2 - 120 Volts AC (VAC) Reactor Protection System (RPS) "A" and "B" (Units 1, 2, and 3)
Figure SSA-09.2 provides a simplified one-line diagram of 110 VAC RPS A and B, Battery Board 1-Panel 9. For this board, load-side breakers for RPS "Bus A" and "Bus B" must coordinate with their respective Motor Generator (MG) Set 175 Ampere (A) output breaker to support the Nuclear Safety Capability Assessment (NSCA) and Fire PRA circuit selection. The limiting coordination case is the 100 A load-side breakers on each RPS bus (i.e., Breakers 903 and 953) and the respective unit MG Set 175 A output breaker. Note that the RPS bus main breakers (i.e., Breakers 902 and 952) are non-automatic breakers and have no trip elements; the breakers are essentially manual switches and play no role in coordination.
E1-13
480V REACTOR MOV BD 1A RPS BUS A BATTERY BOARD 1, PANEL 9 902 (NA) 110 VAC RPS MG SET 1A 480V REACTOR MOV BD 1B 952 (NA) 110 VAC RPS MG SET 1B CIRCUIT PROTECTOR 1A1 CIRCUIT PROTECTOR 1A2 CIRCUIT PROTECTOR 1B1 CIRCUIT PROTECTOR 1B2 ALTERNATE RPS SUPPLY (NOT CREDITED FOR NSCA OR FIRE PRA)
AC MOT GEN AC MOT GEN RPS BUS B MG SET OUTPUT BREAKER (175 A)
MG SET OUTPUT BREAKER (175 A) 903 100A 904 30A 905 15A 906 20A 953 100A 954 30A 955 15A 956 15A 4/0 AWG Cable 4/0 AWG Cable Figure SSA-09.2 110 VAC RPS A and RPS B, Battery Board 1-Panel 9 (Unit 1)
(Similar for Units 2 and 3)
The applicable BFN coordination calculation identified that slight mis-coordination exists between the 100 A load-side breakers and the 175 A MG Set output breakers near the maximum theoretical available fault current from the MG sets. The lower tolerance limit of the 175 A MG Set output breaker instantaneous trip is approximately 1592 A, which is eight A below the maximum fault current of 1600 A from the MG Sets, thus resulting in potential miss-coordination between 1592 A and 1600 A. For simplification purposes, the existing coordination calculation conservatively assumes the available short circuit current at the RPS buses is equivalent to the maximum available fault current at the MG set terminals (1600 A) and thus no system impedance is taken into consideration in determining the maximum available fault current at the RPS buses. A simple benchmark of the available fault current at the RPS buses indicates that maximum available fault current at the RPS buses will be considerably below that required to ensure coordination when the 4/0 American Wire Gauge (AWG) cable between the 175 A MG Set output breaker and the RPS panels is taken into consideration. Maximum available fault current falls below 1592 A after approximately five feet beyond the MG Set output breakers and the cable distance to the RPS buses is significantly greater than five feet.
It is important to note that crediting the impedance of the 4/0 AWG cable between the MG Set output breaker and the respective RPS bus does not constitute "crediting cable length" within the context of this RAI response. Crediting cable length to reduce available fault current is of potential concern when the cable being credited is on the load-side of the downstream breaker.
In this case no credit is taken for cable on the load-side of the 100 A load-side breakers.
E1-14
Crediting the impedance of the 4/0 AWG cable between the breakers only serves to provide a more precise maximum fault current from which to assess actual coordination.
Conclusions Within the context of this RAI response, cable length has not been credited in the NSCA or Fire PRA coordination calculations to reduce available fault current to levels that demonstrate full coordination between upstream and downstream overcurrent protective devices. On this basis, the established fire scenario zones of influence (ZOIs) used in the Fire PRA are independent of electrical coordination considerations, including cable length for load-side overcurrent protective devices.
E1-15
SSA RAI 10 NEI 00-01, "Guidance for Post Fire Safe Shutdown Circuit Analysis," Revision 1, and NFPA 805 identify circuit failure types (hot short, open circuit, short-to-ground) that need to be considered in the circuit analysis. LAR Attachment B, Table B-2 identifies alignment with the guidance of NEI 00-01, Revision 1. The NRC staff noted that certain circuit configurations credit special "shorting switches" as protection against hot shorts. For those components required to meet the nuclear safety performance goals of NFPA 805, provide a list of components that will rely on this protection scheme. Include the equipment type (MOV, SOV (solenoid operated valve), air operated valve, etc.), type of control circuit (grounded or ungrounded, control power transformer (CPT) or non-CPT), fire locations where credit was taken, and any justification for relying on the circuit not failing open in a fire. Identify where any of these circuits are being modified using this configuration and indicate which of these are listed in LAR Attachment S.
RESPONSE
Credit is taken for shorting switches in the NSCA and PRA analyses to prevent or reduce the probability of spurious operation due to hot shorts. This response will focus on credit taken for shorting switches in the NSCA. Credit for shorting switches in the PRA will be discussed in the TVA response to PRA RAI 15 (response to be provided in a future TVA letter). Credit is taken in one of three ways depending on the configuration and the location of the fire as follows.
CASE 1 The control circuits were affected by fire but the shorting switch, the shorting conductors, and the end device (i.e., the actuating coil) were free of fire damage. It was assumed that the spurious operation did not occur. Case 1 was considered deterministically compliant in the NSCA.
CASE 2 The control circuits and the cables containing the shorting conductors were exposed to fire damage. The shorting circuit was assumed to fail in the NSCA. These instances are documented as VFDRs for further disposition in the Fire Risk Evaluation.
CASE 3 The shorting switch and associated panel wiring were exposed to fire damage. The shorting circuit was assumed to fail in the NSCA. These instances are documented as VFDRs for further disposition in the Fire Risk Evaluation. All of the shorting switches are located in the MCR panels in FA 16A.
The equipment that use a shorting switch that is credited either in the NSCA or the PRA to prevent spurious operation are listed in the table below. The table also includes the information concerning the equipment that is requested in the RAI (e.g., equipment type, type of control circuit).
E1-16
Equipment Description Equip Type Type of Control Circuit NSCA Resolution Fire Location (FA)
Shorting Conductor Location (FA)
Device Location (FA)
Modification Status Justification Case 1-FCV-074-0052-XC Div 1 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT Compliant Cables affected by FA 01-02 scenario bordering FA 01-01 01-02 01-05, 5,
16A 5
Existing Design Case 1 1-FCV-074-0066-XC Div 2 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT Compliant 01-01 01-03, 01-04, 01-05, 4,
16A 4
Existing Design Case 1 1-FCV-074-0066-XC Div 2 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT VFDR- 01 0013 01-05 01-03, 01-04, 01-05, 4,
16A 4
Existing Design Case 2 2-FCV-074-0052-XC Div 1 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT Compliant 02-02 02-03, 02-04, 9,
16A 9
Existing Design Case 1 2-FCV-074-0066-XC Div 2 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT Compliant 02-01 8,
- 16A, 16E, 16N 8
Existing Design Case 1 2-FCV-074-0066-XC Div 2 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT Compliant 02-03, 02-04 8,
- 16A, 16E, 16N 8
Existing Design Case 1 3-FCV-074-0066-XC Div 2 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT Not Credited (Credited in PRA only) 03-01 03-02, 12,
- 16A, 16P 12 Existing Design Case 1 E1-17
1-FCV-074-0066-XC Div 2 LPCI Injection Valve spurious CLOSE MOV Ungrounded CPT VFDR-16-0104 16A 01-03, 01-04, 01-05, 4,
16A 4
Existing Design Case 3 2-FCV-074-0052-XC Div 1 LPCI Injection Valve Spurious CLOSE MOV Ungrounded CPT VFDR-16-0116 16A 02-03, 02-04, 9,
16A 9
Existing Design Case 3 1-PCV-069-0015-XO RWCU System Auto Bypass Valve Spurious OPEN AOV 4-20 milliAmpere (mA) current loop VFDR-16-0163 (See Note 1) 16A 16A 01-03 LAR Table S-2 Mod. 90 Case 3 2-PCV-069-0015-XO RWCU System Auto Bypass Valve Spurious OPEN AOV 4-20 mA current loop VFDR-16-0167 (See Note 1) 16A 16A 02-03 LAR Table S-2 Mod. 90 Case 3 3-PCV-069-0015-XO RWCU System Auto Bypass Valve Spurious OPEN AOV 4-20 mA current loop VFDR-16-0171 (See Note 1) 16A 16A 03-03 LAR Table S-2 Mod. 90 Case 3 Note 1: Valves 1, 2, and 3-PCV-069-0015 are only credited in the PRA (i.e., they are not credited in the NSCA). Containment isolation valves 1, 2, and 3-FCV-069-0001, which accomplish the same function, are credited in the NSCA and are referenced in the listed VFDRs.
E1-18
SSA RAI 13 The LAR states that DID and safety margin guidance from NEI 04-02, "Guidance for Implementing a Risk-Informed, Performance-Based Fire Protection Program Under [Title 10 of Code of Federal Regulations] 10 CFR 50.48(c)," and Regulatory Guide (RG) 1.205, "Risk-Informed, Performance-Based Fire Protection for Existing Light-Water Nuclear Power Plants," are used in the risk evaluations when resolving VFDRs. LAR Attachment C, Table C-1 identifies FPP systems and features by fire area credited for DID. DID and safety margin are stated as being evaluated as part of the area-by-area FRE. However, the specific criteria used to determine adequate DID and safety margin is not provided in the LAR. Provide additional discussion of the methods and criteria for evaluating DID and safety margins and summarize the results as required by NFPA 805, Section 4.2.4.2.
RESPONSE
DID was qualitatively evaluated for each FA in the Fire Risk Evaluation. The methods and criteria contained in the calculation are provided below.
DID General A review of the effect of the change on DID was performed using the guidance below from NEI 04-02. NFPA 805 defines DID as:
Preventing fires from starting Rapidly detecting fires and controlling and extinguishing promptly those fires that do occur, thereby limiting damage Providing adequate level of fire protection for structures, systems and components important to safety; so that a fire that is not promptly extinguished will not prevent essential plant safety functions from being performed In general, the DID requirement was considered satisfied if the proposed change did not result in a substantial imbalance among these elements or echelons. The review of DID was qualitative and addressed each of the elements with respect to the proposed change.
Fire protection features and systems relied upon to ensure DID were identified in the assessment (e.g., detection, suppression system).
Consistency with the DID philosophy is maintained if the following acceptance guidelines, or their equivalent, are met:
A reasonable balance is preserved among 10 CFR 50.48(c) DID elements Over-reliance and increased length of time or risk on performing programmatic activities to compensate for weaknesses in plant design is avoided Pre-fire nuclear safety system redundancy, independence, and diversity are preserved commensurate with the expected frequency and consequences of challenges to the system and uncertainties (e.g., no risk outliers). (This should not be construed to mean that more than one NSCA train must be maintained free of fire damage)
Independence of DID elements is not degraded Defenses against human errors are preserved E1-19
The intent of the General Design Criteria in Appendix A to 10 CFR Part 50 is maintained DID Process Each FA was evaluated for the adequacy of DID. In accordance with NFPA 805, Section 2.4.4, Plant Change Evaluation, "the evaluation process shall consist of an integrated assessment of the acceptability of risk, DID, and safety margins." NFPA 805 Section 4.2.4.2 refers to the acceptance criteria in Section 2.4.4. Therefore, fire protection systems and features required to demonstrate an adequate balance of DID are required by NFPA 805 Chapter 4.
The VFDRs and the associated FA risk (i.e., CDF/LERF) and scenario consequences (i.e.,
CCDP/CLERP values) were evaluated to identify general DID echelon imbalances.
Potential methods to balance the DID features were identified ensuring an adequate balance of DID features was maintained for the FA. To aid in the consistency of the review of DID, the following guidance was provided in Table 5-2 of the FRE calculation:
Table 5 Considerations for Defense-in-Depth Determination Method of Providing DID Considerations Echelon 1: Prevent fires from starting Combustible Control Hot Work Control Combustible and hot work controls are fundamental elements of DID and as such are always in place. The issue to be considered during the FREs is whether this element needs to be strengthened to offset a weakness in another echelon thereby providing a reasonable balance. Considerations include:
Creating a new Transient Free Area Creating a new Hot Work Restriction Area Modifying an existing Transient Free Area or Hot Work Restriction Area The fire scenarios involved in the FRE quantitative calculation should be reviewed to determine if additional controls should be added.
Review the remaining elements of DID to ensure an over-reliance is not placed on programmatic activities to compensate for weaknesses on plant design.
E1-20
Table 5 Considerations for Defense-in-Depth Determination Method of Providing DID Considerations Echelon 2: Rapidly detect, control and extinguish promptly those fires that do occur thereby limiting fire damage Detection system Automatic fire suppression Portable fire extinguishers provided for the area Hose stations and hydrants provided for the area Fire Pre-Fire Plan Fire protection systems and features associated with echelon 2 may or may not exist in the fire area of concern. The issues to be considered during the FRE are whether a new fire protection system or feature needs to be installed and/or whether an existing fire protection system or feature needs to be strengthened to offset a weakness in another echelon thereby providing a reasonable balance. Considerations include:
Risk Insights If the VFDR is never affected in a "potentially risk significant" fire scenario, manual suppression capability may be adequate and no additional fire protection systems and features would be required.
If the potentially risk significant fire scenarios are of the type that would benefit from automatic suppression/detection, then consideration should be given to including the system for DID.
Recovery Actions:
If the fire area requires recovery actions, then as a minimum, detection and manual suppression capability should be considered, and fixed suppression should be considered.
If a fire area contains neither suppression nor detection and a recovery action is required, consider adding detection or suppression Fire Fighting Activities:
If fire fighting activities in the fire area are expected to be challenging (either due to the nature of the fire scenario or accessibility to the fire location) then both detection and suppression should be considered.
Fire Scenarios:
The fire scenarios involved in the FRE quantitative calculation should be reviewed to determine the types of fires and reliance on suppression should be evaluated in the area to best determine options for this element of DID.
E1-21
Table 5 Considerations for Defense-in-Depth Determination Method of Providing DID Considerations Echelon 3: Provide adequate level of fire protection for systems and structures so that a fire will not prevent essential safety functions from being performed Walls, floors ceilings and structural elements are rated or have been evaluated as adequate for the hazard.
Penetrations in the fire area barrier are rated or have been evaluated as adequate for the hazard.
Supplemental barriers (e.g., ERFBS, cable tray covers, combustible liquid dikes/drains, etc.)
Fire rated cable Reactor coolant pump oil collection system (as applicable)
Guidance provided to operations personnel detailing the required success path(s) including recovery actions to achieve nuclear safety performance criteria.
If fires occur and they are not rapidly detected and promptly extinguished, the third echelon of DID would be relied upon.
The issue to be considered during the FRE is whether existing separation is adequate (or over relied upon) and whether additional measures (e.g., supplemental barriers, fire rated cable, or recovery actions) are required to offset a weakness in another echelon thereby providing a reasonable balance.
The fire scenarios involved in the FRE quantitative calculation should be reviewed to determine the fires evaluated and the consequence in the area to best determine options for this element of DID.
Considerations include:
Risk Insights:
If the VFDR is never affected in a "potentially risk significant" fire scenario, internal fire area separation may be adequate and no additional reliance on recovery actions is necessary.
If the VFDR is affected in the same "potentially risk significant" fire scenario, internal fire area separation may not be adequate and reliance on a recovery action may be necessary.
If the consequence associated with the VFDRs is high (e.g.,
CCDP>E-01 or by qualitative NSCA assessment) regardless of whether it is in the same potentially risk significant scenario, a recovery action, supplemental barriers, or other modification should be considered.
There are known modeling differences between a Fire PRA and nuclear safety capability assessment due to different success criteria, end states, etc. Although a VFDR may be associated with a function that is not considered a significant contribution to core damage frequency, the VFDR may be considered important enough to the NSCA to retain as a recovery action. For example, the NSCA for a BWR may always require high pressure injection (HPCI or RCIC), while the PRA models additional injection sources as options for makeup. Recovery actions to restore high pressure injection could be suggested for DID, although the FRE calculation demonstrates a successful change in risk without relying on the high pressure systems.
Operations Insights:
If the sequence to perform a recovery action is particularly challenging then including the action for defense-in-depth may be considered. An example would be a recovery action that is unique in nature, time critical and/or not included in the emergency response procedures such that the MCR staff may not be able to quickly recognize and perform the required action.
DID - Recovery Action Considerations Reliance on Recovery Actions in lieu of protection is considered part of the third echelon of DID. Per NFPA 805, recovery actions are defined as: "Activities to achieve the nuclear safety performance criteria that take place outside of the MCR or outside of the primary E1-22
control(s) station for the equipment being operated, including the replacement or modification of components."
If the VFDR is characterized as a "Separation Issue," and the change in risk (i.e., CDF and LERF) is acceptable, a recovery action can be considered as a means to provide an adequate level of DID. Guidance on the need to establish/rely upon a recovery action was provided in FRE calculation Table 5-2.
SM Assessment A review of the effect of the change on SM was performed. An acceptable set of guidelines for making that assessment are summarized below. Other equivalent acceptance guidelines may also be used.
Codes and standards or their alternatives accepted for use by the NRC are met Safety analysis acceptance criteria in the licensing basis (e.g., FSAR, supporting analyses) are met, or provides sufficient margin to account for analysis and data uncertainty The requirements related to SMs are described for each of the specific analysis types used in support of the FRE. These analyses are grouped into the following three categories:
Fire Modeling Plant System Performance Fire PRA The evaluation of these categories is provided below.
Fire modeling The development and quantification of fire scenarios in support of the Fire PRA followed the guidance available in NUREG/CR-6850. Consistent with the Fire PRA process, not all the fire zones required a detailed analysis, because some of them were analyzed conservatively due to their relatively lower risk contributions. Fire compartments were evaluated on a case by case basis during the Fire PRA development process for determining the level of detailed fire modeling analysis necessary. The highest level of fire modeling analysis was applied to selected compartments on an as-needed basis when screening techniques could mask true risk contributors and practical/useful insights. Compartments requiring less detailed analysis are modeled in the Fire PRA conservatively (e.g., failing all targets in the fire zone for every fire scenario, failing targets at time of ignition). In either case, SM was maintained by the level of conservatism included in the modeling approach. The fire modeling analysis can be generally classified in three groups:
Fire zones treated as "full zone damage" - These zones were screened from detailed analysis as they were included in the fire risk profile of the plant assuming all the Fire PRA targets were failed at the time of fire ignition with the total frequency of fixed and transient ignition sources. In practice, they were represented as one fire scenario in a single fire zone and the corresponding multi compartment scenarios.
Fire zones that have been subdivided into fire scenarios for crediting severity factors and specific location characteristics within the fire zone - In this group of scenarios, times to damage were assumed to occur at the time of ignition of specific ignition E1-23
sources. There was no credit for detection or suppression features in scenarios in these fire zones.
Fire zones receiving detailed fire modeling analysis in which severity factors, detection and suppression features were credited for the individual fire scenarios -
For these scenarios, determination of target damage was necessary.
For the last group, the quantification process required analytical fire modeling for determining time to target damage, time to detection and suppression, and time for the different fire zones to reach hot gas layer. The modeling approaches that were applied to fire zones requiring detailed analysis ensure that safety margins are maintained.
Time to target damage calculations were considered conservative and therefore providing safety margin as cables were considered damaged when exposed to environmental temperatures equal to or exceeding the corresponding damage criteria. That is, heat transfer calculations throughout the thickness of the targets to determine internal target temperatures were not credited in the analysis. Targets (e.g., cables) were assumed damaged as soon as the fire generated environmental temperatures reach the damage criteria.
Time to detection and suppression calculations were considered conservative because no credit was provided to such features in the Fire PRA for the first set of targets affected by the fires (i.e., targets within the ZOI).
Time to generating hot gas layer conditions in the fire zone. The fire sizes selected for these calculations bounded the worst case fire scenario in the fire zone. That is, the combination of the ignition source and intervening combustibles deemed to generate the highest heat release rate was selected for determining the time to hot gas layer conditions. This approach generally resulted in shorter times to hot gas layer conditions, which maintained safety margin in the analysis.
Therefore, fire modeling performed in support of the transition was performed within the Fire PRA utilizing codes and standards developed by industry and NRC staff to provide realistic yet conservative results. The models were verified and validated in authoritative publications, such as NUREG-1824, "Verification and Validation of Selected Fire Models for Nuclear Power Plant Applications." In general, the fire modeling performed in support of the Fire Risk Evaluations was performed using conservative methods and input parameters that are based upon NUREG/CR-6850. While this is generally not ideal in the context of best estimate probabilistic risk analysis, it is a pragmatic approach given the current state of knowledge regarding the uncertainties related to the application of the fire modeling tools and associated input parameters for specific plant configurations.
Plant System Performance NEI 04-02 Section 5.3.5.3 states:
"The development of the FRE may involve the re-examination of plant system performance given the specific demands associated with the postulated fire event. The methods, input parameters, and acceptance criteria used in these analyses needs to be reviewed against that used for the plant design basis events. This review would serve to establish that the Safety Margin inherent in the analyses for the plant design basis events have been preserved in the analysis for the fire event and therefore satisfy the requirements of this section."
E1-24
In the development of the NSCA, plant system performance parameters were evaluated to ensure they supported the nuclear safety performance criteria and establish safe and stable plant operation in the event of a fire. These evaluations utilized methods, input parameters and acceptance criteria consistent with that used for the plant design basis events. Failure to meet design basis criteria resulted in a VFDR.
Performance parameters from the internal events PRA were re-examined and modified as required given the specific demands of a fire event. Methods, input parameters and acceptance criteria used in the PRA were realistic and were in accordance with the American Society of Mechanical Engineers/American Nuclear Society (ASME/ANS)
Standard RA-Sa-2009, "Standard for Level 1 / Large Early Release Frequency Probabilistic Risk Assessment for Nuclear Power Plant Applications," dated February 2, 2009, as adopted by Regulatory Guide 1.200, "An Approach for Determining the Technical Adequacy of Probabilistic Risk Assessment Results for Risk-Informed Activities," Revision 2.
Therefore, a safety margin consistent with the internal events PRA was maintained.
Fire PRA NEI 04-02 Section 5.3.5.3 states:
"The quantification for fire related CDF/LERF is expected to be based on the plant PRA model. It is recognized that use of a plant PRA model in a fire risk assessment often requires model modifications to be performed. These modifications may include altering basic event failure probabilities, adding basic events, and logic structure changes.
These changes should be evaluated against the methods and criteria for the overall internal events PRA model development for consistency, or confirmation of bounding treatment, to confirm that the Safety Margin inherent in the PRA model is preserved. It is also appropriate to confirm that the quantified model is sufficient to treat the fire induced core damage sequences. If the analysis was performed using the plant PRA model with no modifications other than normalizing the initiating event frequency to 1.0, and setting other non-credited events to TRUE or 1.0, then the Safety Margin inherent in that model can be considered to have been preserved and no further assessment for Safety Margin is necessary for this category."
The Fire PRA was developed based on the internal events PRA, to which fire-specific modifications were made to model the plant response to a fire. These changes were documented in the TVA FIRE PRA - Task 5 Fire-Induced Risk Model. The PRA was developed in accordance with the ASME/ANS RA-Sa-2009 Standard, which requires identifying new or modified success criteria to support the Fire PRA (i.e., Requirement PRM-B7). The Fire PRA has undergone an initial industry peer review and a follow up supplemental industry peer review, in order to ensure the Fire PRA meets the appropriate quality standards of ASME/ANS RA-Sa-2009 as adopted by Regulatory Guide 1.200 Revision 2.
Circuit failure probabilities for spurious events from the Circuit Failure Analysis tasks were incorporated as relevant. The circuit failure mode probabilities were assigned following state of the art industry practices and guidance, which are generally based on conservative assumptions. Finally, operator actions in the internal events PRA were reviewed in view of fire scenarios, and instruments that were found to be required to support the human reliability assessment were added to the model. In addition, the human error probability E1-25
(HEP) values were re-evaluated to account for the effect of fires, and, as relevant, additional fire-specific human failure events were added to the model (i.e., PRM notebook).
Based on Fire PRA model changes, the selection of input parameters, and the quantification process, it was concluded that the safety margin inherent in the Fire PRA model was preserved.
E1-26
SSA RAI 15 The shutdown method is transitioning from SISBO to fire protection procedures using the performance-based analysis of NFPA 805. Provide a description of the steps being undertaken to ensure a complete and smooth transition including RAs (including feasibility),
modifications, training, and operating procedures.
RESPONSE
The plan for transition of fire safe shutdown instructions includes migration away from strategies that instruct the operators to take detrimental actions such as intentionally disconnecting offsite power, commonly referred to as Self-Induced Station Blackout (SISBO). The new procedures will be executed concurrently with the symptom based Emergency Operating Instructions (EOIs) and other operating procedures. This is in contrast to the current strategy in the safe Shutdown Instructions (SSIs) that calls for exiting the EOIs and other operating procedures when the SSIs are entered. The symptom based strategy will allow the operators to use the systems and equipment that are available as opposed to being limited by procedure to a single, predetermined success path.
The following actions are planned to ensure a smooth transition to new procedures.
- 1. Preparation and review of new procedures The procedures required to implement the new NFPA 805 Fire Safe Shutdown will be prepared and implemented before NFPA 805 transition. The structure of the procedures will utilize the current EOIs supplemented by FA specific instructions that will include risk and DID recovery actions. These instructions will be similar to the current SSIs that contain actions specific to fires in that area and identify the credited safe shutdown path. Modifications will be in progress while the new SSIs are being implemented, and therefore, revisions to incorporate the modification effects will be a continuous process.
- 2. Validation of new procedures The new and revised procedures will be validated prior to implementation to ensure they are feasible as written given the plant configuration. The feasibility validation will follow the Frequently Asked Question (FAQ) 07-0030 guidance.
- 3. Training operators on the new fire shutdown procedure strategy Operator training will be developed using the systematic approach to training. Initial training will be conducted prior to transition addressing the new procedure structure and safe shutdown strategies. Operators will be trained on the effect of modifications on operating procedures, similar to the current training process.
The new procedure strategy is already familiar to the operators because it will utilize the current EOIs for monitoring and controlling critical parameters and utilization of plant systems. The operation of the systems that is unique to a fire condition, such as the use of recovery actions, will be similar to the way the equipment is currently operated in the SSIs.
The new procedure strategy has already been implemented in SSIs for FAs 25-1, 25-2, 25-3 and 26 and operators have received training on the changes.
E1-27
FM RAI 01.c NFPA 805, Section 2.4.3.3, states: "The PSA [probabilistic safety assessment] approach, methods, and data shall be acceptable to the AHJ [authority having jurisdiction]..." The NRC staff noted that fire modeling comprised the following:
The algebraic equations implemented in FDTs [Fire Dynamics Tools] and Fire Induced Vulnerability Evaluation, Revision 1 (FIVE) were used to characterize flame radiation (heat flux), flame height, plume temperature, ceiling jet temperature, and hot gas layer (HGL) temperature.
The Consolidated Model of Fire and Smoke Transport (CFAST) was used in the multi-compartment analysis (MCA), and for the temperature sensitive equipment hot gas layer study.
Fire Dynamics Simulator (FDS) was used to assess the MCR habitability, and in the plume/hot gas layer interaction and temperature sensitive equipment ZOI studies.
Section 4.5.1.2, "Fire PRA" of the LAR states that fire modeling was performed as part of the FPRA development (NFPA 805 Section 4.2.4.2). Reference is made to Attachment J, "Fire Modeling V&V, [Validation & Verification]" for a discussion of the acceptability of the fire models that were used.
Regarding the acceptability of the PRA approach, methods, and data:
- c. During the audit the NRC staff learned that wall and corner effects were not accounted for in the HGL and multi-compartment fire modeling analysis. Provide technical justification for not considering wall and corner effects in the fire modeling calculations.
RESPONSE
Hot gas layer (HGL) temperatures were calculated in the scoping fire modeling analysis, detailed fire modeling analysis, multi-compartment analysis (MCA), and the MCR analysis.
The majority of ignition sources modeled in these analyses were found to be located in the center of the fire compartment; therefore the wall and corner effects were not applicable to the majority of fire scenarios. The fire modeling tools used to calculate the HGL temperature within each analysis are listed below:
Analysis Fire Modeling Tool for HGL Calculations Scoping Fire Modeling Analysis Method of Beyler Consolidated Model of Fire Growth and Smoke Transport (CFAST)
Detailed Fire Modeling Analysis Method of McCaffrey, Quintiere, and Harkleroad (MQH)
Multi-Compartment Analysis Method of Beyler MQH CFAST Main Control Room Analysis Fire Dynamics Simulator (FDS)
E1-28
The HGL was calculated using the Method of MQH in the detailed fire modeling analysis and as a screening step in the MCA. The MQH method assumes the fire is located at the center of the room and wall/corner effects were not analyzed. A review identified those fire scenarios where the ignition source is located within two feet of a wall or corner and a sensitivity study was performed to determine if the fire location would affect HGL temperatures in those scenarios. The sensitivity analysis utilized CFAST to place the fire at a wall or in a corner and evaluate the resulting HGL temperatures. The sensitivity analysis determined that, for these scenarios, the HGL temperatures calculated using the MQH correlation were greater than the HGL temperatures calculated using CFAST, which incorporates the wall and corner effects. Because the HGL calculations were used to determine target damage only, the fire scenarios using the MQH correlation in the detailed fire modeling analysis and the MCA are conservative.
The CFAST models used to calculate HGL temperatures in the scoping fire modeling analysis modeled the fires at the actual location of the ignition sources and included the properties of the walls. Therefore, wall and corner effects have been accounted for in the scoping fire modeling analyses using CFAST.
The scoping fire modeling analysis and the MCA also used the Method of Beyler for calculating HGL temperatures. Based on NUREG-1824, Volume 3, Section 3.3, the Beyler method of calculating HGL temperatures is not limited to the center of the fire compartment and therefore is not invalidated if the fire is flush with a wall or in a corner of the compartment. Because the Beyler method is not affected by the location of the fire, no sensitivity analysis was required for these fire scenarios.
The MCA used CFAST as a refined screening step for scenarios that could generate a damaging HGL using the method of Beyler and MQH. CFAST was used for these scenarios to determine if a damaging HGL could be created in the exposed compartment. For these scenarios, the "worst case" fire scenario in the fire compartment (i.e., the scenario with the bounding HRR) was evaluated using CFAST. The sensitivity analysis re-analyzed the HGL temperatures with the fire located at a wall and in a corner of the compartment. The results of this analysis determined that all scenarios with the fire in the center of the compartment, where the exposed compartment did not reach an HGL, still did not reach an HGL with the fire at the wall or corner. Therefore, the results of these scenarios will not be affected by the wall and corner effects.
The MCR analysis used FDS to calculate HGL temperatures for operator abandonment.
Similar to the other fire modeling analyses, the majority of ignition sources within this fire compartment are located away from the walls, such that the wall and corner effects would not be applicable. In the analysis documentation, a sensitivity analysis evaluated the HGL temperature with wall and corner effects. The sensitivity analysis resulted in abandonment times greater than those used in the MCR analysis; therefore the MCR analysis is conservative and bounds the effects of a fire located at the wall or corner. Due to the size of the MCR, the HGL temperatures increased local to the ignition source, rather than throughout the entire compartment. Additionally, the optical density, not the HGL temperature, was determined to be the limiting criteria for habitability in most fire scenarios.
E1-29
PRA RAI 01.b Section 2.4.3.3 of NFPA 805 states that the probabilistic safety assessment (PSA is also referred to as PRA) approach, methods, and data shall be acceptable to the AHJ, which is the NRC. Regulatory Guide (RG) 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a FPRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a FPP consistent with NFPA 805. RG 1.200, "An Approach For Determining the Technical Adequacy of Probabilistic Risk Assessment Results for Risk-Informed Activities," describes a peer review process utilizing an associated ASME/ANS standard (currently ASME/ANS-RA-Sa-2009) as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established for evaluations that could influence the regulatory decision. The primary results of a peer review include the F&Os identified by the peer review and their subsequent resolution.
Clarify the following dispositions to fire F&Os and Supporting Requirement (SR) assessments identified in LAR Attachment V that have the potential to impact the FPRA results and do not appear to be fully resolved:
- b. F&O 4-2 against CS-B1:
The disposition to F&O 4-2 states that it has been addressed by including in the BFN FPRA the risk contribution of secondary fires due to the presence of a specific type of current transformer in electrical buses. In the BFN NSCA and FPRA, current transformer cables are included in the analysis. The corresponding cables were routed so that ignition sources that may affect the cables are identified, an ignition frequency is assigned, and adjacent targets can be identified for secondary fires as they are postulated. However, there is insufficient information to understand how that analysis was performed. Provide a more detailed description of the method used to quantify the risk associated with this event including assumptions made about extent of the impact from the secondary fire. Because these secondary fires occur in fire areas beyond the originating fire, include in the explanation the impact to other components and to recovery actions required to be conducted in the areas of secondary fires. Also, explain whether the feasibility of those actions was considered.
RESPONSE
CTs that meet all of the following criteria are considered potentially susceptible to secondary fires and included in the BFN Fire PRA:
The CT has secondary-circuit cables that leave the enclosure that houses the CT.
Otherwise, the secondary fire would be at the same location as the initiating fire and would already be accounted for in the analysis.
The CT is not used for differential overcurrent protection. In such cases, an open circuit in the secondary circuit would lead to immediate automatic protective action to de-energize the associated primary circuit, which would prevent development of a secondary fire. Although there is a small probability that protective action could fail, such transformers are screened to avoid excessive conservatism.
E1-30
The ratio of the number of turns in the secondary coil to the number of turns in the primary coil (i.e., the turns ratio) is greater than 1200:5.
Secondary fire consideration in the analysis consisted of the following steps:
- 1. Identification of the electrical cabinets housing the CTs.
- 2. Identification of the cables connecting to the CTs capable of generating the open circuit.
- 3. Identification of fire scenarios that could damage the cables identified in Step 2. These were the fires that could potentially generate a secondary fire at the electrical cabinet housing the CT (i.e., cabinets identified in Step 1).
- 4. Identification of the targets (i.e., cable tray or conduits) within the zone of influence of the cabinets identified in Step 1. These were the targets that could be damaged by the secondary fires that are in addition to the electrical cabinet housing the CT. These targets were identified by walkdowns and drawing reviews. A zone of influence of 10 feet horizontally from the panels was utilized. Assuming a 1 MW fire, which is the largest heat release rate for cabinets listed in NUREG/CR-6850, Appendix G and using the point source flame radiation model, the thermoplastic damage criteria for heat flux is reached in approximately six feet. Therefore, the use of 10 feet is conservative.
Vertically, the zone of influence extends from the panel up to the ceiling of the room.
- 5. Addition of the targets identified in Step 4 to the fire scenarios identified in Step 3. That is, the fire scenarios in Step 3 included an expanded target set to account for the effects of the secondary fires.
The effects of secondary fires on recovery actions have been considered. Specifically:
There are no recovery actions taken at the panels susceptible to secondary fires.
There are two recovery actions credited in the Turbine Building (i.e., FA 26). Under certain circumstances, a secondary fire in FA 26 could result from a fire originating in FA 16.
o One recovery action isolates Control Air to the Reactor Buildings to ensure that containment isolation valves will fail closed.
o The second recovery action places the new EHPM Pump in operation locally in the Turbine Building.
No components involved in the secondary fire at the Electrical Boards or Generators are required to support a recovery action.
o The control air isolation will be performed on EL 565 at the south end (near column m-line) of the Turbine Building. The locations for secondary fires are all located in the north end (column a-line to d-line) of the Turbine Building at EL 586 or above. Because the valves are at a lower elevation and have significant spatial separation, any secondary fire from open CTs would not adversely affect the feasibility of performing the control air isolation action.
o The new EHPM pump is planned to be operated locally, when necessary, on EL 565 or below at the south end (near column g-line) of the Turbine Building at the pumps location. The locations for secondary fires are all located in the north end (column a-line to d-line) of the Turbine Building at EL 586 or above.
Secondary fires that could fail the EHPM pump normal power supply are included E1-31
in the Fire PRA model, which inherently accounts for the secondary fire failure of the recovery action to operate the EHPM pump from the normal power supply.
The EHPM pump alternate power supply and cabling will not be in the secondary fire zone of influence. Because the pump is at a lower elevation and has significant spatial separation, any secondary fire from open CTs would not adversely affect the feasibility of performing the pump operation action.
In summary, the analysis for secondary fires was incorporated in the Fire PRA. The targets in the ZOI of the secondary fires were included in the target set for the scenarios that could generate a secondary fire. The effect of secondary fires on the recovery actions was considered.
E1-32
PRA RAI 01.j Section 2.4.3.3 of NFPA 805 states that the probabilistic safety assessment (PSA is also referred to as PRA) approach, methods, and data shall be acceptable to the AHJ, which is the NRC. Regulatory Guide (RG) 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a FPRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a FPP consistent with NFPA 805. RG 1.200, "An Approach For Determining the Technical Adequacy of Probabilistic Risk Assessment Results for Risk-Informed Activities," describes a peer review process utilizing an associated ASME/ANS standard (currently ASME/ANS-RA-Sa-2009) as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established for evaluations that could influence the regulatory decision. The primary results of a peer review include the F&Os identified by the peer review and their subsequent resolution.
Clarify the following dispositions to fire F&Os and Supporting Requirement (SR) assessments identified in LAR Attachment V that have the potential to impact the FPRA results and do not appear to be fully resolved:
- j.
F&O 3-13 against FSS-D3 The disposition to this F&O states that credit for automatic and manual suppression is applied to each damage state based on the suppression determined to have been activated. Clarify how the time to detection and suppression system activation was determined for both scoping and detailed fire scenarios. Include in this clarification an assessment of fire detection and suppression systems effectiveness in the context of fire scenarios analyzed.
Additionally, discuss the process by which target sets are selected in developing the damage states of a detailed fire modeling scenario. Include in this discussion how target set damage times, hot gas layer effects, and secondary combustibles influence this selection process.
RESPONSE
In general, the time to detection and suppression system activation for both the scoping and detailed fire modeling was determined using NUREG-1805, Fire Dynamics Tools (FDT) 10.
For each ignition source, the fire point of origin was determined by field inspection.
Distances from the point of origin to the nearest fixed suppression/detection device and to the ceiling were used as inputs to the NUREG-1805 FDT10 spreadsheets, to calculate the device activation time. The heat release rate (HRR) input in the spreadsheet was varied to determine the minimum HRR required to activate the suppression/detection device. The fire growth and propagation analysis was then used to determine the time to reach the minimum HRR required for suppression/detection. This minimum HRR included the ignition source, propagation to adjacent cabinet vertical sections and spread/propagation to secondary cable trays, as appropriate. The effectiveness of the automatic detection and suppression systems was evaluated by observing the location of the device(s), beam pockets, and obstructions in the area during plant walkdowns. Walkdowns and plant drawings were utilized to confirm the location of the individual detectors and sprinklers with relation to the fire scenario in which activation is credited.
E1-33
The scoping and detailed fire modeling scenarios were developed in accordance with NUREG/CR-6850, Appendix P. For ignition sources that could spread to secondary combustibles, a fire growth and propagation analysis was performed to analyze the growing effects of the fire and its ZOI. The fire modeling analyses credited suppression to arrest fire growth and propagation, thereby limiting target damage. Once automatic suppression activated or manual suppression was initiated, further fire growth and propagation was not postulated for that damage state. The ZOI at the time to suppression was calculated and used to determine target damage. The time to suppression included time to activate devices, any necessary delays for pre-discharge alarms, and an agent discharge time.
Suppression timing and target damage sets for suppression success and failure for each damage state are documented as individual fire scenarios.
Fire damage states were generated for each ignition source fire scenario at the time at which significant events occur (e.g., automatic suppression, damage to critical targets, HGL exceeding critical damage temperatures). A target damage ZOI was calculated for each fire damage state and the associated target set was determined. When the HGL temperature exceeded the critical damage temperature, for a specific type of target (e.g., thermoplastic, thermoset), all targets within the fire compartment that had an equal or lesser damage temperature were considered to be damaged.
However, the transient analysis within the Reactor Building was analyzed separately from the generic detailed fire modeling analysis described above. For the Reactor Building transient fire scenarios, the non-suppression probability term was calculated following the process described in NUREG/CR-6850, Appendix P, and NUREG/CR-6850 Supplement 1, Chapter 14, so that both automatic and manual suppression features were incorporated in the analysis. Under this approach, the non-suppression probability was calculated as a function of time. Furthermore, automatic suppression credit was only applied to damage states after the first fire sprinkler had been qualitatively assumed to actuate. In the case of a transient fire below a cable tray stack, with a fire sprinkler directly between the first stack and a nearby cable tray stack that was not ignited by the initial transient fire, automatic suppression credit was not applied to the first stack.
E1-34
PRA RAI 01.l Section 2.4.3.3 of NFPA 805 states that the probabilistic safety assessment (PSA is also referred to as PRA) approach, methods, and data shall be acceptable to the AHJ, which is the NRC. Regulatory Guide (RG) 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a FPRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a FPP consistent with NFPA 805. RG 1.200, "An Approach For Determining the Technical Adequacy of Probabilistic Risk Assessment Results for Risk-Informed Activities," describes a peer review process utilizing an associated ASME/ANS standard (currently ASME/ANS-RA-Sa-2009) as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established for evaluations that could influence the regulatory decision. The primary results of a peer review include the F&Os identified by the peer review and their subsequent resolution.
Clarify the following dispositions to fire F&Os and Supporting Requirement (SR) assessments identified in LAR Attachment V that have the potential to impact the FPRA results and do not appear to be fully resolved:
- l.
F&O 4-17 against PRM-B5:
The disposition to this F&O does not address the peer review team's observation regarding treatment of detrimental actions and identification of new fire-induced accident sequences. Provide the following:
- a. Discussion of the extent to which success of fire-specific actions were considered as a potential failure mode of components modeled in the FPRA model, including any new resulting accident sequences as appropriate.
- b. Description of the review performed to identify new accident sequences, including timing considerations not in the internal events. Include in this description a disposition of the examples identified by the F&O.
RESPONSE
The LAR, Attachment V, included an incorrect disposition for Facts and Observations (F&O) 4-17. The disposition to F&O 4-17 is revised to state:
"A review was conducted of 1) screened initiating events from the internal events PRA model documentation, and 2) MSO impacts on plant safe shutdown and on the potential for new initiating events. The results of this review are documented in the Component Selection report, subtask 7.2.1, section 6.2, and Table 16. The review included an evaluation of generic and plant specific MSO scenarios to identify the potential for any unique failure impacts. No new sequences were identified which were not already included in the Fire PRA model, or adequately addressed by system logic models as modified for the Fire PRA. A review of fire emergency procedures will be performed after procedure development is complete."
As stated in LAR Section W.1, "Fire PRA results and risk insights are based on the post-transition plant, which is based on the as-built plant with the following characteristics: 1) the plant includes modifications credited for the NFPA 805 transition, 2) the plant operation E1-35
relies on recovery actions credited in the Fire PRA, and 3) no detrimental actions are taken.
"Detrimental actions" is a term used to designate a set of operator actions currently proceduralized in the as-built, as-operated plant, aimed at precluding the fire-induced spurious operation of equipment, but that the Fire PRA determined to be not beneficial in terms of risk. As such, these "detrimental actions" are eliminated in the transition to NFPA 805." No new accident sequences beyond what are currently modeled in the BFN internal events model were required based upon success of fire-specific actions.
New timing considerations from Multiple Spurious Operations (MSOs) and other fire induced effects were taken into account in the Fire PRA model. This included accounting for the various accident sequence specific Human Reliability Analysis (HRA) timings. However, this did not introduce any new accident sequences in the Fire PRA event trees beyond what is currently modeled in the internal events model.
F&O 4-17 provides the following examples:
MSO scenarios MSO scenarios including overfill, system overpressurization, spurious opening of system drain valves, and water hammer including flooding were investigated during the BFN MSO expert panel. The MSO scenarios were addressed by systematically evaluating the scenarios and dispositioning them for new accident sequences. This review resulted in no additional accident sequences beyond what is currently modeled in the internal events model.
Fire-Induced Floods See the TVA response to PRA RAI 01.m (in TVA letter CNL-14-001, dated January 10, 2014) for discussion relating to consideration of fire-induced flooding scenarios.
Loss of power to the control room annunciator tile boards In regards to loss of power to the control room annunciators, the Fire PRA recognized that operator performance plays a significant role in the plant response to fire events.
Particularly, operators can interface with and otherwise manipulate systems in ways that are either beneficial or detrimental to safe shutdown. These operator actions are largely dependent on indicators and related instrumentation (e.g., alarms) that are used by the operators to understand the status of the plant, and determine what actions to take based on the guidance in the EOIs, alarm response procedures (ARPs) and/or fire response guidance and procedures. Unlike for most internal events where the availability of instrumentation is not likely to be challenged, fires could fail or otherwise cause spurious operation of instrumentation used by the operators at likelihoods that cannot be neglected.
During the review of annunciators and instrumentation, no detrimental actions were identified thus creating no new accident sequences beyond what are currently modeled in the BFN internal events model.
E1-36
PRA RAI 07 Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. In letter dated July 12, 2006, to NEI (ADAMS Accession No. ML061660105), the NRC established the ongoing FAQ process where official agency positions regarding acceptable methods can be documented until they can be included in revisions to RG 1.205 or NEI 04-02. Methods that have not been determined to be acceptable by the NRC Staff require additional justification to allow the NRC Staff to complete its review of the proposed method.
LAR Attachment C identifies a number of systems for which heating ventilation and air conditioning (HVAC) is needed to meet its performance goal. Describe the HVAC modeling performed to support the FPRA and whether HVAC cable tracing and fire modeling were performed to support this modeling.
RESPONSE
An environmental qualification calculation established the upper temperature limit at which electrical components could still function without adverse effects. The thermal capabilities of equipment were evaluated in the calculation through review of manufacturers published data, industry standards, environmental qualification documentation, and materials and equipment reference reports. Based on this calculation, the upper temperature limit that electrical equipment could survive without adverse effects for a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> mission time was 140 degrees Fahrenheit (°F).
The Fire PRA credited only the HVAC Systems for those rooms that were not screened out based on room heatup calculations. HVAC Systems were only needed in rooms where the temperature in the room increased to above 140°F in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Based on the room heatup calculations performed, HVAC systems were not required in the Unit 1, 2, and 3 Electric Board Rooms, the Unit 3 Shutdown Board Rooms or the Control Building, except for the MCR.
The Fire PRA model considered the effects of fire for the credited HVAC components, including air handling units, chillers, and dampers. The cables for the credited components were traced and were subject to failure due to fire in the model as well.
For those rooms where HVAC is credited, in accordance with fire response procedures, operator action is required to start alternate air cooling if normal HVAC fails. The fire response procedures also include actions to open doors and install fans for ventilation purposes. Both of these operator actions are credited in the Fire PRA, where applicable, and modeled for failure to perform the action.
E1-37
PRA RAI 11 Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established.
Identify any changes made to the internal events (IEPRA) or FPRA since the last full-scope peer review of each of these PRA models that are consistent with the definition of a "PRA upgrade" in ASME/ANS-RA-Sa-2009, "Standard for Level 1/Large Early Release Frequency for Nuclear Power Plant Applications," as endorsed by Regulatory Guide 1.200.
RESPONSE
A PRA upgrade is defined in ASME/ANS RA-Sa-2009 as the incorporation into a PRA model of a new methodology or significant changes in scope or capability that affect the significant accident sequences or the significant accident progression sequences. This could include items such as new human error analysis methodologies, new data update methods, new approaches to quantification or truncation, or new treatments of common cause failure.
No new human error analysis methodology, new data update method, new approach to quantification or truncation, and no new treatment of common cause failure have been employed in the internal events PRA model since the 2009 Peer Reviews (i.e., May 2009 for Internal Events and August 2009 for Internal Flooding). No changes have been made to the accident progression sequences in the internal events PRA. Therefore, the changes to the internal events PRA since the 2009 Peer Reviews do not meet the criteria for a PRA upgrade.
The Fire PRA model changes since the Follow-On Peer Review of June 2012 include:
Errors were found in the cable locations used in the peer reviewed model. The correction of the cable locations affected the targets for various fire scenarios and thus, affected the components failed due to fire for various fire scenarios.
Emergency DG overloading due to spurious loading of the shutdown boards was not included in the peer reviewed model. The failure mode of loss-of-power to the various shutdown boards due to DG overloading has been added to the model. This resulted in additional equipment failures for various fire scenarios.
Modifications and recovery actions not included in the peer reviewed model were subsequently credited in the final model used to support the NFPA 805 LAR. The modifications and recovery actions prevent failures or recover from new failures introduced by the correction of the cable locations and failures resulting from Emergency DG overloading.
Some fire scenarios previously analyzed using the scoping fire modeling techniques were re-analyzed using detailed fire modeling techniques. However, the detailed fire modeling techniques were previously used for a limited number of scenarios in the E1-38
peer reviewed model. Therefore, there was a change in the scope of detailed fire modeling performed; however, there was no change in methodology.
There have been significant changes to the Fire PRA model since the June 2012 peer review. The changes were a result of error corrections such as cable routing errors, diesel overload model correction, expansion of existing approaches and techniques contained in the peer reviewed model, and refinements to Fire HRAs contained in the new dominant sequences. Subsequent to the June 2012 peer review, no new methodologies were used to revise the Fire PRA model that supported the results/conclusions used in the NFPA 805 LAR. However, the modeling changes made since the peer review were significant changes in capability that affected the significant accident sequences and the significant accident progression sequences. Therefore, the changes to the Fire PRA model constitute a PRA upgrade.
E1-39
PRA RAI 11.a Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established.
Also, address the following:
a) Clarify why the SRs in Table V-1 were found to be not applicable (N/A) by the peer review team. Identify which SRs are not applicable (e.g., the type of reactor or the NFPA 805 application). If there are specific and multiple reasons that SRs are determined to be N/A, identify the reason for each SR, grouping them as appropriate.
In general, SRs that are not deemed applicable to an application require application specific justification, so all reasons provided should include a discussion of the NFPA 805 application characteristics. For example, i) FSS-C7 requires that dependencies among multiple suppression paths be evaluated and modeled. Since there are fire scenarios crediting, at a minimum, at least one type of automatic suppression and possible manual suppression if automatic fails, describe the basis for dismissing this SR as inapplicable.
ii) IGN-A6 requires use of Bayesian updating (or equivalent) when generic and plant-specific ignition frequency data are combined. Describe whether any plant-specific datum is used for Browns Ferry at any of the units. If no, why not? If used, describe why this SR deemed not-applicable.
iii) HRA-B4 addresses the role of instrumentation failures due to fire in HRA.
Dismissal of this as inapplicable suggests that such instrumentation failures were not considered in the HRA. Clarify and justify this SR being inapplicable.
iv) For these to be inapplicable (QNS-C and QNS-D2 on p. V-9), QNS-A, -B and -D must also be deemed such, but they do not appear to be.
RESPONSE
In general, the Fire PRA model followed the guidelines of NUREG/CR-6850 and the High Level Requirements (HLRs) and Supporting Requirements (SRs) of ASME/ANS RA-Sa-2009. Listed below are the HLRs and SRs that were deemed not applicable (N/A) to the Fire PRA model by the full scope peer review team and the justifications for classifying them as such.
- 1) The Fire PRA model was adapted from the internal events model using the same inputs and parameters, except for modifications to represent fire risk events. In the development of the Fire PRA model, the requirements of the following HLRs and SRs were not affected. They were evaluated during the internal events peer review and met Category II or better. Some SRs had associated F&Os which were resolved as specified in LAR Attachment U.
E1-40
DA-A IE-C11 QU-C3 SY-A20 DA-B IE-C14 SC-A1 SY-B3 DA-C LE-A SY-A9 SY-B4 DA-E LE-B SY-A11 IE-C6 LE-C SY-A15 IE-C10 LE-D SY-A16
- 2) SR SY-A19 was identified in LAR Table V-1 as "not applicable" but should be marked as "Met." SY-A19 was determined to be not applicable at the time of the peer review because the BFN Fire PRA model used the internal events PRA model information for unavailability of components. The new components added for the Fire PRA, except for the EHPM pump, were modeled for unavailability caused by damaging fires only, because the out-of-service unavailability of the new components is included in the component or function it supports. Because the EHPM pump was added to the Fire PRA model for both unavailability due to test or maintenance, as well as a damaging fire causing unavailability, the SR was met for Capability Category I, II, and III. Therefore, this SR should be identified as "Met." LAR Attachment V, Table V-1, which provides the list of High Level Requirements (HLRs) and SRs that are not applicable, is revised to remove SY-A19 (in the fourth column of the Table) from Table V-1.
- 3) Two new initiating events were identified in the Fire PRA review. However, these were already accounted for in the existing event tree/accident sequences. No new event trees/accident sequences were implemented in the Fire PRA. See the disposition to PRM-B3 on page V-73 of the BFN NFPA 805 LAR for a detailed description of the modeling of fire induced initiating events. Therefore, the following HLRs/SRs were identified as not applicable:
AS-A2 AS-A9 AS-B7 IE-A6 AS-A3 AS-A11 AS-C IE-A7 AS-A4 AS-B1 IE-A1 IE-A9 AS-A6 AS-B2 IE-A2 IE-A10 AS-A7 AS-B5 IE-A3 IE-B AS-A8 AS-B6 IE-A5 PRM-B6
- 4) There were no new success criteria modeled in the Fire PRA that have been identified that require plant response model construction. The definition of success criteria, as specified in ASME/ANS RA-Sa-2009, is the minimum number or combinations of systems or components required to operate to ensure safety functions are satisfied. Additional components included in the Fire PRA model did not affect the minimum number or combinations of systems or components required to operate. They were added to provide another level of redundancy, and as such, the following Supporting Requirements were deemed not applicable:
PRM-B8 SC-A3 SC-B2 SC-A2 SC-A4 SC-C2
- 5) PRM-B15 was deemed not applicable because there was no new Fire PRA specific accident progression identified beyond the onset of core damage which addresses LERF estimation in the internal events PRA.
E1-41
- 6) The Fire PRA HRA initially used the same human actions as the internal events model. These human actions were further refined in accordance with the Supporting Requirements for HRA-A, HRA-B, HRA-C, and HRA-D. Because all the requirements in the HR HLRs were included in the HRA HLRs, the following HLRs/SRs were deemed not applicable:
HR-A HR-C HR-H1 HR-B HR-D
- 7) SRs IE-C15 and IE-D were previously covered by the IGN and CF SRs while SRs under MU-A, MU-B, MU-C, MU-D, and MU-E were covered under the FMU SRs.
- 8) The cable selection process does not include any assumed routing cases. The Fire PRA team identified a set of components for which the location of associated cables was identified. All other components were assumed to fail for all fire scenarios; therefore CS-A11, CS-C3 and FSS-E4 were deemed not applicable.
- 9) SR FQ-F2 requires documentation to support any claim of nonapplicability of referenced requirements in Section 2 of ASME/ANS RA-Sa-2009 standard. The Fire PRA analysis did not claim nonapplicability of any of those requirements, and as such, FQ-F2 was deemed not applicable.
- 10) SR IE-C7 requires a time trend analysis to meet Capability Category III, but no time trend analysis is required for Capability Category II. The BFN PRA did not include a time trend analysis, and as such, IE-C7 was deemed not applicable.
- 11) Internal flooding does not affect the Fire PRA; therefore the following HLRs/SRs were deemed not applicable.
IFEV-A IFPP-B IFSN-A IFSO-A IFEV-B IFQU-A IFSN-B IFSO-B IFPP-A IFQU-B
- 12) SR ES-B5 provides relief for components susceptible to fire-induced spurious operations. The provisions of this SR have not been used in the Fire PRA, therefore it was deemed not applicable.
- 13) Based on the plant-specific review of BFN fire events from January 1, 2000 to December 31, 2009, for Units 1, 2 and 3, a total of 67 fire events were identified and reviewed, with 59 of these events being immediately screened from further consideration based on where and when the fire events occurred. The eight remaining events were placed into their respective fire ignition bins. Only one of these events was identified as potentially challenging, due to fire in a cabinet located in a flammable environment.
No unusual patterns of occurrence or outlier fire events were noted. Given that there were no unusual patterns of fires and no more than one fire event per bin that was not immediately screened based on where and when the fire event occurred, no plant specific updates of generic frequencies were considered. Guidance in NUREG/CR-6850, Section 6.5.2 states that if there are only a small number of fire events in the plant, use of generic fire frequencies is warranted. With only one plant E1-42
specific fire event associated with each bin, the frequency of that bin would increase significantly if Bayesian updates were employed. Typically the fire frequency for each bin was smaller than once per 100 years, while a plant will have less than 100 years of total experience. Therefore, with just one fire event the frequency would increase significantly after performing a Bayesian update. The updated frequency would be overly conservative based on a small probability that the event occurs early in the observation period.
Because generic industry parameters were used in the BFN analysis, the following SRs were deemed not applicable:
DA-D IE-C2 IE-C4 IE-C13 FSS-E2 IE-C3 IE-C12 IGN-A6
- 14) No parameters outside the bounds of HLR-FSS-C or HLR-FSS-D have been credited in the Fire PRA, therefore, FSS-E1 was deemed not applicable.
- 15) The Alarm Response procedures, the EOIs, and the abnormal operating instructions (AOIs) were all reviewed to determine whether there were any spurious alarms or indications that could cause an undesired operator action that could cause a detrimental effect in the Fire PRA. All of the alarms required verification, either by using indications from other parameters, or by manual verification. The AOIs were reviewed and were determined that upon entry into the procedure multiple indications and conditions are required to be verified as a part of the procedure.
Almost all of the steps in the EOIs have multiple sources and channels in the MCR.
Other steps have multiple means of detection from the MCR. All other spurious indications from a single instrument that could cause an undesired operator action were assumed to be failed in the Fire PRA. Therefore, HRA-B4 was deemed not applicable.
- 16) During development of the Fire PRA, the plan was to screen compartments using guidance from NUREG/CR-6850 and the ANS/ASME PRA Standard. Although several compartments fell below the criteria specified in NUREG/CR-6850 and the ANS/ASME PRA Standard, no compartments were screened out of the analysis. All compartments were retained for further analysis and therefore, the following HLRs/SRs were deemed not applicable:
QLS-A QNS-A*
QNS-C QLS-B QNS-B*
QNS-D*
- Note: Except for QNS-D2, these HLRs were originally marked as "Met" because a screening analysis was performed. Although several compartments fell below the criteria laid out in NUREG/CR-6850 and the ANS/ASME PRA Standard, no compartments were screened out in the analysis. All compartments were retained for further analysis so each of these HLRs and SRs included therein were judged to be not applicable as well. LAR Attachment V, Table V-1 is revised to add QNS-A, QNS-B and QNS-D to the Table and delete QNS-D2 (in the fifth column of the Table) from the Table.
- 17) There are no subtrees, modules or split fractions used in the Fire PRA model, therefore AS-B4 and QU-B10 were deemed not applicable:
E1-43
- 18) The Fire PRA is a spatial analysis so any comparison would require the identification of a plant with a similar arrangement of cables, raceways, and ignition sources. No such plant exists; therefore, QU-D4 was deemed not applicable.
- 19) The Fire PRA model does not use non-nuclear power industry sources for fire ignition frequencies; therefore, SRs IGN-A2 and IGN-A3 were deemed not applicable.
- 20) With regard to SR FSS-C7, there were no dependencies between automatic suppression and manual suppression. If automatic suppression failed, the fire PRA did not take credit for fire brigade manual initiation of the failed automatic suppression system. The only dependency was between automatic detection and manual suppression. If automatic suppression was successful, there was no need for manual suppression. If automatic suppression failed, and automatic detection was successful, Operations personnel would dispatch the fire brigade to manually suppress the fire. If automatic detection failed, manual detection would prompt action from the fire brigade to manually suppress the fire. The dependency between Fire PRA modeling of automatic and manual detection and suppression is further discussed in the TVA response to PRA RAI 01 Part j in this enclosure. Therefore, this SR was deemed not applicable.
- 21) SR AS-A10, this was previously marked as "not applicable" but should be marked as a "Not Met" finding. This SR is similar to AS-A1 and AS-A5, in regard to the fire emergency response procedures. The Fire PRA model followed the internal events model. The Fire PRA model took credit for draft fire emergency response procedures that provided descriptions of operator actions dealing with fires. The Fire PRA team worked closely with the overall NFPA 805 transition team to develop the draft fire emergency response procedures. While no significant changes are expected to be made to the draft procedures, any change made during the development of the final procedures will be appropriately incorporated into the model and will be reviewed for adequacy consistent with the commitment specified in LAR Attachment S, Table S-3, Implementation Item 33. This will also be discussed in the TVA response to PRA RAI 01 Part d (in a future letter). In addition, LAR Attachment V, Table V-1 is revised to delete AS-A10 (in the first column of the Table) from the Table.
E1-44
PRA RAI 11.b and c Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established.
Also, address the following:
b) At the time of the follow-on peer review, it is not clear that fire modeling was well developed. The fire scenario analysis was developed under conservative assumptions for target damage (F&O 3-13), credited for detection and suppression for all target failures without consideration for time to damage or system activation (F&O 3-13), utilized a one-point model (F&O 8-3), discounted "non-propagating" fire scenarios (F&O 5-18), and employed an unreviewed analysis method for severity factors (F&O 3-14). The current fire scenario analysis, however, represents all risk-significant fire scenarios as detailed scenarios that employ a progression of target damage states in time and that credit automatic and manual suppression at each damage state considering the systems that have been determined to activate at that time. As a result, it appears that the updates made to the fire scenario analysis may be characterized as a PRA upgrade.
Describe whether the above or other changes are considered PRA upgrades. If not, provide justification. If so, indicate if a focused-scope peer review was performed for these changes consistent with the guidance in ASME/ANS-RA-Sa-2009, as endorsed by RG 1.200, Revision 2, and describe any findings from that focused-scope peer review and the resolution of these findings.
- c. If a focused-scope peer review has not been performed for changes characterized as a PRA upgrade, describe what actions will be implemented to address this review deficiency.
RESPONSE
There have been significant changes to the Fire PRA model since the June 2012 peer review. The changes were a result of error corrections such as cable routing errors, diesel overload model correction, expansion of existing approaches and techniques contained in the peer reviewed model, and refinements to Fire HRAs contained in the new dominant sequences. Subsequent to the June 2012 peer review, no new methodologies were used to revise the Fire PRA model that supported the results/conclusions used in the NFPA 805 LAR. However, the modeling changes made since the peer review were significant changes in capability that affected the significant accident sequences and the significant accident progression sequences. Therefore, the changes to the Fire PRA model constitute a PRA upgrade. Furthermore, a focused-scope peer review has not been performed subsequent to making these changes.
E1-45
Because the Fire PRA has been upgraded since the June 2012 peer review, a focused-scope peer review will be performed prior to transition to NFPA 805. The focused scope peer review will include at a minimum, the following elements: Fire PRA Cable Selection and Location (CS), Human Reliability Analysis (HRA), Fire Risk Quantification (FQ), and Uncertainty and Sensitivity Analysis (UNC). To ensure this peer review is performed, a new implementation item, Implementation Item 47, is added to LAR Table S-3. The LAR Table requires that certain items be completed prior to the implementation of the NFPA 805 fire protection program. The new Implementation Item reads: "Perform a focused-scope peer review of the Fire PRA. The peer review will include, as a minimum, the following elements:
Fire PRA Cable Selection and Location (CS), Human Reliability Analysis (HRA), Fire Risk Quantification (FQ), and Uncertainty and Sensitivity Analysis (UNC)."
E1-46
PRA RAI 13 Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing an associated ASME/ANS standard (currently ASME/ANS-RA-Sa-2009) as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established.
The BFN Post-Fire HRA report states that actions related to emergency depressurization require "special treatment to allow a more refined application in the fire model"; however, the treatment appears to be non-conservative. The discussion in Section 5.1.6 suggests that in an attempt to simplify modeling logic, fire-induced operation of safety relief valves (SRVs) are not modeled as failing high pressure coolant injection (HPCI)/reactor core isolation coolant but are still credited for successful long-term emergency depressurization. Clarify the treatment of actions related to emergency depressurization as well as the modeling of fire-induced operation of SRVs.
RESPONSE
Fire induced opening of the SRVs was modeled in the Stuck Open Relief Valve (SORV) logic of the Fire PRA. The necessary cable fire effects were attached to the existing SORV logic from the Internal Events (IE) model. In the Fire PRA, the single SORV logic and the multiple SORV logic is applied to the correct sequences through the event tree structure similar to the manner in which it is applied in the IE model.
The "special treatment" section in the BFN Post-Fire Human Reliability Analysis report, Section 5.1.6, was intended only to describe how the short and long term emergency depressurization human actions were modeled in the Fire PRA. The model was constructed so the fire-induced SRV operations, along with the spurious operation of an SRV or stuck open SRV failure modes, failed the HPCI and RCIC Systems in the proper manner. The logic was such that two or more open SRVs failed both short term and long term HPCI and RCIC. One open SRV failed long term (i.e., greater than four hours of operation) HPCI and RCIC, but allowed credit for HPCI and RCIC for up to four hours.
E1-47
PRA RAI 23.a Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established. The primary results of a peer review are the F&Os recorded by the peer review and the subsequent resolution of these F&Os.
Clarify the following dispositions to fire F&Os and SR assessment identified in LAR Attachment U that have the potential to impact the FPRA results and do not appear to be fully resolved:
- a. 1-12 (Finding against SC-B1 Met at CC-II, SY-B6 Not Met at CC-I/II/III, and SY-B7 Met at CC-I/II/III)
The F&O cites the lack of engineering bases for three specific assumptions; 1) that active ventilation is not required, 2) keep-fill systems are not required, and 3) the high pressure coolant injection (HPCI) system is dependence on "quad" cooling for 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> of post-accident operation. The disposition to the F&O does not provide a complete basis for these assumptions. Clarify the following:
i The disposition states that room heat-up calculations were performed after the peer review that resulted in removal of several HVAC system dependencies.
Describe the room heat-up calculations that were performed, identify what modeling tools were used, explain which dependencies were removed as a result of these calculations, and identify where this analysis is documented.
ii The disposition explains that the keep fill systems are reliable (i.e., monitored daily by operations and based on operator experience system leaks are not great enough to create a water hammer condition). Describe the engineering basis for not modeling the keep-fill function in the PRA.
iii The disposition states that based on operational experience and operator interview, the condensate and condensate booster pumps are assumed to survive 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> without forced cooling. However, it is noted that Modification 104 identified in Table S-2 of the LAR commits to upgrading the Unit 3 condensate booster pumps to be larger capacity pumps. Clarify whether dependency on forced cooling for these pumps was modeled or removed, and if this dependency was removed, provide justification that the new condensate booster pumps are not dependent on forced cooling.
RESPONSE
Part a.i Three transient thermal models were constructed in the GOTHIC Version 7.2b computer program to estimate the temperature response over a 72-hour period for selected areas following a transient that initiates safety-related loads and a loss of room cooling. The following models were evaluated.
E1-48
Control Bay Model - Twenty seven rooms in the Control Building and Reactor Building were analyzed. The calculation included evaluations for battery rooms, battery board rooms, auxiliary instrument rooms, MCRs, 250 VDC Shutdown Battery Rooms, 480V Shutdown Board Rooms, and Unit Board Rooms.
Unit 3 Diesel Generator Building Model-Includes 4kV Shutdown Board Rooms 3EA, 3EC, 3EB, 3ED and the 4kV Shutdown Bus Tie Board Room.
Battery Room Number 4 Board Room Model Similarly, a separate calculation was developed to estimate the temperature response in the Reactor Building corner pump rooms over a 72-hour period following a transient that initiates safety-related loads and concurrent failure of the dedicated air cooling units located therein.
An environmental qualification calculation established the upper temperature limit at which electrical components can still function without adverse effects. The thermal capabilities of equipment were evaluated in the calculation through review of manufacturers published data, industry standards, environmental qualification documentation, and materials and equipment reference reports. Based on this calculation, the upper temperature limit that electrical equipment could survive without adverse effects for a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> mission time was 140°F.
Based on these calculations, the HVAC dependencies for the Control Building except for the Units 1 and 2 and Unit 3 MCRs, the Unit 1, 2 and 3 Electric Board Rooms, and the Unit 3 Shutdown Board Rooms have been removed from the Internal Events PRA model. The calculations showed that these rooms remain below 140°F for a 72-hour period following shutdown. Therefore, a flag was used to remove the HVAC dependency from the following areas:
Unit 1 Electric Board Room (flag SW_U1_HVAC_EBR)
Unit 2 Electric Board Room (flag SW_U2_HVAC_EBR)
Unit 3 Electric Board Room (flag SW_U3_HVAC_EBR)
Unit 1 and 2 Control Building (flag SW_U12_HVAC_CB)
Unit 3 Control Building (flag SW_U3_HVAC_CB)
Unit 3 Shutdown Board Room (flag SW_U3_HVAC_SDB)
The information described above can be found in the following calculations:
Thermal Analysis of Control Bay Rooms, Unit 3 Diesel Generator Building Shutdown Board Rooms and Battery Room #4 Board Room Following Loss of Cooling Thermal Analysis of RB Corner Rooms Following Loss of Room Cooling.
BFN Probabilistic Risk Assessment - Heating Ventilation and Air Conditioning System.
Upper Boundary Temperature for Mild Environments Related to Environmental Qualification of Electrical Equipment Part a.ii During normal plant operations, the preferred method for maintaining the Residual Heat Removal (RHR) or Core Spray system charged is the Pressure Suppression Chamber (PSC) head tank. The keep-fill system is considered reliable because the PSC System is a E1-49
passive system maintained by the PSC head tank. In addition, any significant loss of pressure is easily identified, because the discharge pipe pressures for RHR and Core Spray are routinely monitored.
The PSC head tank liquid level is maintained at a height sufficient to pressurize the supported systems discharge piping to the minimum pressure specified in the Technical Requirements Manual (TRM) as follows:
(1) Units 2 and 3 RHR Loop I at > 48 psig.
(2) Units 2 and 3 RHR Loop II at > 35 psig.
(3) Unit 1 RHR loop minimum pressures are reversed from Units 2 and 3 above, with RHR Loop I at > 35 psig and RHR Loop II at > 48 psig.
The pressure values referenced above are those required to maintain the pressure in the highest elevation piping for each ECCS Loop above atmospheric.
Instruments that monitor the system pressure provide indication in the MCR and channel checks are performed routinely to ensure proper charging of the RHR and Core Spray Systems.
With the PSC head tank volume available, the PSC System pressure would remain adequate to prevent ECCS line voiding for at least six hours after PSC pump failure on Units 1 and 3. The Unit 2 PSC head tank capacity can only last about 2.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> after PSC pump failure.
The keep-fill system is not modeled in the Internal Events PRA model. The only waterhammer modeling included in the Internal Events PRA model is when suppression pool cooling is in operation during power operation and a loss of offsite power occurs.
Because the motor operated valves (MOVs) cannot reposition when the pumps trip, water from the RHR loop to the suppression pool will drain to the Suppression Pool and the RHR pump could cause a waterhammer event when it re-starts. The PRA model assumes that the RHR loop fails if these conditions exist. However, during a fire, spurious operations of valves can cause pipes to drain and other fire induced failures can fail the keep fill system.
These waterhammer events are modeled in the Fire PRA model for both the RHR and Core Spray Systems.
Part a.iii As noted in the LAR Table S-2, Modification 104 commits to upgrading the Unit 3 Condensate Booster Pumps (CBPs) to larger capacity pumps. The upgraded pumps, which are already installed in Units 1 and 2, will be water cooled using the Raw Cooling Water (RCW) System, and will no longer require HVAC support. The PRA model already includes the RCW System dependency for the Condensate System for all three units. Therefore, the resolution of F&O 1-12 will remain valid after implementation of Modification Item 104.
E1-50
PRA RAI 23.b Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established. The primary results of a peer review are the F&Os recorded by the peer review and the subsequent resolution of these F&Os.
Clarify the following dispositions to fire F&Os and SR assessment identified in LAR Attachment U that have the potential to impact the fire PRA results and do not appear to be fully resolved:
- b. 2-23 (Finding against SY-A3 Met at CC-I/II/III)
Since this F&O was issued modeling of HVAC dependency has been removed for the Unit 3 Electric Board Rooms for both the IEPRA and FPRA. Confirm that HVAC operation is not assumed in the fire PRA to protect equipment from smoke damage or sensitive electronics from thermal damage. Also, confirm that HVAC operation is not needed to ensure access/egress through fire areas during a response.
RESPONSE
Due to the conservative methods used in the Scoping Fire Modeling for all the fire compartments and in the Detailed Fire Modeling for specific, risk-significant fire scenarios, HVAC System operation in the fire compartment where the fire was located was not assumed in the Fire PRA to protect equipment from smoke damage or sensitive electronics from thermal damage.
Operator actions have not been credited for fire locations affected by a fire, including traversing the FA(s) to reach another. Additionally, HVAC operation is not necessary to ensure access/egress through FAs that are not subjected to the exposing fire.
E1-51
PRA RAI 23.e Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established. The primary results of a peer review are the F&Os recorded by the peer review and the subsequent resolution of these F&Os.
Clarify the following dispositions to fire F&Os and SR assessment identified in LAR Attachment U that have the potential to impact the FPRA results and do not appear to be fully resolved:
- e. 3-10 (Finding against HR-I3 Not Met at CC-I/II/III, IE-D3 Not Met at CC-I/II/III, LE-F3 Not Met at CC-I/II/III, SY-C3 Not Met at CC-I/II/III, SC-C3 Not Met at CC-I/II/III, QU-E2 Met at CC-I/II/III, QU-E4 Not Met at CC-I/II/III, QU-F4 Not Met at CC-I/II/III, and QU-E1 Not Met at CC-I/II/III)
A detailed compilation of identified sources of uncertainty is presented in Table A8.1 of the internal events Quantification report (i.e., QU - Probabilistic Risk Assessment Quantification) which includes rationale for assumptions made and indication of internal events PRA modeling impact. However, there appears to be no assessment provided of the potential impacts of these uncertainties to risk estimates.
Attachment U of the LAR indicates for this F&O that the fire PRA has its own uncertainty analysis. Explain how the results of the internal events uncertainty analysis were used to inform the fire PRA.
RESPONSE
The Fire PRA has its own uncertainty analysis, and there is no documented assessment of the potential effects of the internal events uncertainties to the Fire PRA risk estimates.
However, the Fire PRA model was constructed on the framework of the Internal Events PRA model. Thus, the modeling assumptions and basic events or revised versions of these to account for internal events/fires apply to both the internal events and Fire PRA models.
Because the nature of these assumptions and the nature of these basic events are relatively unchanged, the sources of uncertainty related to these aspects of the Internal Events PRA model carry into the Fire PRA model.
The two primary areas of uncertainty involve:
Aleatory uncertainty due to inherent randomness of a stochastic process.
Epistemic uncertainty due to a lack of or weaknesses in the state of knowledge.
Typically, it is only possible to model phenomenological events in a deterministic manner, i.e., either something occurs or it does not. Thus, the event tree and fault tree logic reflects only one or, perhaps, a small set of outcomes for a given set of conditions. Incompleteness of the PRA model contributes to the models epistemic uncertainty. The risk importances of epistemic uncertainties are assessed via sensitivity analyses.
E1-52
Most of the items identified in Table A8.1 of the Internal Events Quantification Report involve standard PRA assumptions or methods. The types of uncertainties considered in the Internal Events PRA in Table A8.1 include:
System trains required to meet a function for different sequences (e.g., SRVs)
Systems not credited in the PRA (e.g., ADS, aux boiler)
Exclusion of failures modes based on low probability (e.g., pipe ruptures, manual valve disc failures)
Flow diversion included or excluded System or component boundaries Required support system dependencies Mission and exposure times Timing for Operator Actions ISLOCA size definition Assumed EPU thermal power Assumed normal plant configuration (e.g., system alignment, inventory available)
These assumptions and methods of the Internal Event PRA propagate directly into the Fire PRA and their effect is either assessed directly in the Fire PRA parametric uncertainty analysis or by sensitivity analyses. For instance, Monte Carlo sampling was performed to propagate parametric uncertainties through the Fire PRA model to generate probability distributions for BFN Units 1, 2, and 3 fire CDF and LERF.
Items such as mission times, success criteria, phenomena, accident progression definition, support systems and initial plant configuration, would not change due to a fire. The sources of uncertainty related to these aspects of the Internal Events PRA model carry into the Fire PRA model.
However, the uncertainties for some of the items identified in Table A8.1 required changes or additional investigation in the Fire PRA. The Human Reliability Analysis assumptions were investigated in the context of a Fire PRA. The Human Error Probabilities (HEPs) values were adjusted for fire on a fire compartment level, and new HFEs were created to account for recoveries that are unique to the fire model. Similarly, new components, component boundaries and failure modes were considered and modeled in the Fire PRA. In addition, the Fire PRA models new systems and functions such as the EHPM system, and rapid vessel flood-up by condensate that are not in the internal Events PRA. The models were also updated to address any new plant specific scenarios for MSOs of concern for model completeness. With the exception of fire-specific HRA response time considerations, the Internal Events PRA sequence/system success criteria were retained for the fire-induced risk model.
A review was conducted of: 1) screened initiating events from the Internal Events PRA model documentation, and 2) MSO effects on plant safe shutdown and on potential for new initiating events. The results of this review are documented in the Component Selection report, subtask 7.2.1, Section 6.2, and Table 16. The review of generic and plant-specific MSOs would identify any unique failure effects. No new sequences were identified which were not already included in the Fire PRA model, or adequately addressed by system logic models as modified for the Fire PRA.
E1-53
PRA RAI 23.g Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established. The primary results of a peer review are the F&Os recorded by the peer review and the subsequent resolution of these F&Os.
Clarify the following dispositions to fire F&Os and SR assessment identified in LAR Attachment U that have the potential to impact the FPRA results and do not appear to be fully resolved:
- g. 4-4 (Finding against IE-C6 Not Met at CC-I/II/III)
This F&O notes that instrument tap failure (i.e., leaks) are screened from the internal events PRA. The F&O disposition explains that instrument lines were considered to contribute to the very small LOCA initiating event category, and are therefore not otherwise addressed. Explain how the potential for fire-induced failure of instrument lines was addressed in the fire PRA. Include discussion of potential line failure and the effect of impacts of fire on the pressure signal
RESPONSE
Fires will not directly result in loss of integrity of a sensing line because instrument line piping is considered a passive mechanical component given a fire. As described in LAR Attachment B, the guidance of NEI 00-01, Section 3.2.1.2, was used in assuming that fire damage exposure to instrument stainless steel sense line piping (i.e., non-heat sensitive piping material) connected to the reactor vessel does not adversely affect its ability to perform its pressure boundary or safe shutdown function.
For instruments adversely affected by sense line fire exposure, the Fire PRA model assumes failure of the instrument signal by including the associated instrument sense lines in the fault trees along with the instruments. The instrument was assumed to fail in a fire scenario if the associated sense lines were targets.
E1-54
PRA RAI 23.h Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established. The primary results of a peer review are the F&Os recorded by the peer review and the subsequent resolution of these F&Os.
Clarify the following dispositions to fire F&Os and SR assessment identified in LAR Attachment U that have the potential to impact the FPRA results and do not appear to be fully resolved:
- h. 4-32 (Findings against SY-A17 Not Met at CC-I/II/III, SY-A8 Met at CC-I/II/III, and SY-B9 Met at CC-I/II/III)
The disposition to this F&O explains that per NUREG/CR-6928, "Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants," external equipment used to monitor under voltage, ground faults, differential faults, and other protection schemes for individual breakers are considered part of the breaker, and therefore failures related to such equipment was assumed to be comprised by the failure of the breaker. Please clarify whether the breaker coordination evaluation in the fire PRA would make this F&O inapplicable to the fire PRA. Otherwise, explain how circuit breaker protection monitoring is accounted for in the fire PRA. In particular discuss fire impact on cables associated with the associated protection scheme and interlocks located or extending outside of the cabinet where the circuit breaker is housed that could fail the function of the circuit breaker.
RESPONSE
F&O 4-32 refers to the PRA modeling of electrical board normal and alternate power supplies without considering the breakers and circuitry necessary for these power supplies.
The breaker coordination evaluation assessed the ability for protective devices to selectively isolate loads in the event of an electrical fault without tripping the entire power supply.
Therefore, the breaker coordination evaluation does not make F&O 4-32 inapplicable to the Fire PRA.
The Fire PRA model includes circuit breaker protection functions. The cable selection for the required breaker protection function included cables and cables for interlocks extending outside of the board where the circuit breaker is housed that could fail the protection function of the circuit breaker. External DC power supplies and related cables required for protective relay functions and trip control power for the breakers were also included as dependencies. Therefore, fire effects on cables associated with the associated protection scheme and interlocks located or extending outside of the cabinet where the circuit breaker is housed that could fail the function of the circuit breaker are encompassed in the Fire PRA.
E1-55
PRA RAI 23.j Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established. The primary results of a peer review are the F&Os recorded by the peer review and the subsequent resolution of these F&Os.
Clarify the following dispositions to fire F&Os and SR assessment identified in LAR Attachment U that have the potential to impact the FPRA results and do not appear to be fully resolved:
- j.
5-3 (Finding against DA-B2 Not Met at CC-I/II/III)
Section 5.0 of the internal events Data Analysis report (i.e., the DA.01 - Probabilistic Risk Assessment - Data Analysis) states that plant specific raw data was reviewed to identify outlier components and that none were found; however, that review or related data analysis was not found in the report. Describe how raw data was analyzed for outliers and criteria used to determine an outlier.
RESPONSE
Outliers were identified by visually observing the data set. No formal analysis was done. No outliers were identified in any revision of the Data Analysis calculations issued following the Internal Events Peer Review.
The Data Analysis calculation has been revised as follows to include a discussion on how outliers were analyzed.
Plant specific evidence (raw data) was reviewed to determine if any outlier components exist, that is, components within a group that have a significantly different failure rate than other components in the group. This was done qualitatively through visual inspection of the prior versus posterior distributions for data outside the gradual trend of values in the overall data set. Outlier criterion follows the generic examples highlighted in ASME SR DA-B2 including only components compatible with the general population data set. The review of plant specific failure data did not reveal any statistically dissimilar results in the failure rates of components within a type code group.
E1-56
PRA RAI 23.k Section 2.4.3.3 of NFPA 805 states that the PRA approach, methods, and data shall be acceptable to the NRC. RG 1.205 identifies NUREG/CR-6850 as documenting a methodology for conducting a fire PRA and endorses, with exceptions and clarifications, NEI 04-02, Revision 2, as providing methods acceptable to the staff for adopting a fire protection program consistent with NFPA-805. RG 1.200 describes a peer review process utilizing ASME/ANS-RA-Sa-2009 as one acceptable approach for determining the technical adequacy of the PRA once acceptable consensus approaches or models have been established. The primary results of a peer review are the F&Os recorded by the peer review and the subsequent resolution of these F&Os.
Clarify the following dispositions to fire F&Os and SR assessment identified in LAR Attachment U that have the potential to impact the FPRA results and do not appear to be fully resolved:
- k. 5-30 (Finding against DA-C13 Not Met at CC-I or /II/III)
The disposition to the F&O indicates that the potential for coincident maintenance events was reviewed and additional discussion was added to the internal events Data Analysis report (i.e., DA.01 - Probabilistic Risk Assessment - Data Analysis) to address the impact of differences in Technical Specifications for shared systems of multi-unit plants related plant status. This discussion, however, does not appear to be presented in the cited report. Explain this inconsistency or describe how the impact of the difference in Technical Specifications for shared systems was addressed when determining test and maintenance unavailability.
RESPONSE
A discussion is included in the DA.01 - BFN Probabilistic Risk Assessment - Data Analysis Calculation on how coincident maintenance events were analyzed through work week assessment reviews. Revision 2 of DA.01 included the following statement to address Technical Specification differences on multi-unit systems: "Shared systems at BFN are governed by global Tech Spec designated as Unit 0 so that unavailability of a component in a shared system affects the entire system for all units." No other formal analysis of Technical Specification differences for multi-unit plant systems was documented.
Unavailability data is extracted and assessed from the Cause Determination Evaluation reports. These plant failure reports also document examples of multi-unit unavailability (e.g.,
an outage on Unit 2 renders a Unit 1 component unavailable). This information allows for the capture of unavailability and is included as described in the plant specific test and maintenance unavailability section. DA.01 has been revised to include the following:
"Instances where shared systems impact unavailability on more than one unit are captured by the Cause Determination and Evaluation process (e.g., unavailability of a DG, a common Unit 1 & 2 system, during a Unit 2 outage can render an ECCS system unavailable on Unit 1)."
The effect of differences in Technical Specifications for shared systems is also addressed by existing plant processes designed to identify high risk configurations involving multi-unit systems. These on-line work management processes include evaluating PRA guidelines, Technical Specification Limiting Conditions for Operation Requirements, minimizing E1-57
division/train/loop/channel interferences and other procedurally driven assessments to ensure no coincident maintenance on multi-unit systems occur. The Work Activity Risk Management procedure governs this process.
E1-58
ENCLOSURE 2 Tennessee Valley Authority Browns Ferry Nuclear Plant, Units 1, 2, and 3 Summary of BFN NFPA 805 RAI Response Dates RAI Question Number Type of Response (days)
Actual Date of Response Fire Protection Engineering (FPE)
FPE 01 60 CNL-13-141 December 20, 2013 FPE 02 60 CNL-13-141 December 20, 2013 FPE 03 60 CNL-14-001 January 10, 2014 FPE 04 60 CNL-14-001 January 10, 2014 FPE 05 60 CNL-14-001 January 10, 2014 FPE 06 60 CNL-13-141 December 20, 2013 FPE 07 60 CNL-13-141 December 20, 2013 FPE 08 60 CNL-14-006 January 14, 2014 FPE 09 60 CNL-14-006 January 14, 2014 FPE 10 90 Future letter E2-1
RAI Question Number Type of Response (days)
Actual Date of Response FPE 11 90 Future letter FPE 12 90 Future letter FPE 13 120 Future letter Safe Shutdown Analysis (SSA)
SSA 01 60 CNL-13-141 December 20, 2013 SSA 02 60 CNL-14-006 January 14, 2014 SSA 03 60 CNL-14-006 January 14, 2014 SSA 04 60 CNL-13-141 December 20, 2013 SSA 05 60 CNL-14-001 January 10, 2014 SSA 06 60 CNL-14-006 January 14, 2014 SSA 07 60 CNL-14-001 January 10, 2014 SSA 08 60 CNL-13-141 December 20, 2013 SSA 09 60 CNL-14-006 January 14, 2014 SSA 10 60 CNL-14-006 January 14, 2014 SSA 11 60 CNL-13-141 December 20, 2013 SSA 12 60 CNL-13-141 December 20, 2013 E2-2
RAI Question Number Type of Response (days)
Actual Date of Response SSA 13 60 CNL-14-006 January 14, 2014 SSA 14 60 CNL-13-141 December 20, 2013 SSA 15 60 CNL-14-006 January 14, 2014 Programmatic (PROG)
PROG 01 60 CNL-13-141 December 20, 2013 PROG 02 60 CNL-13-141 December 20, 2013 Fire Modeling (FM)
FM 01, part a 90 Future letter FM 01, part b.i 60 CNL-13-141 December 20, 2013 FM-01, part b.ii 60 CNL-13-141 December 20, 2013 FM-01, part b.iii 90 CNL-14-001 January 10, 2014 FM 01, part c 60 CNL-14-006 January 14, 2014 FM 01, part d.i 60 CNL-14-001 January 10, 2014 FM-01, part d.ii 90 CNL-14-001 January 10, 2014 FM 01, part e 60 CNL-13-141 December 20, 2013 FM 01, part f 60 CNL-14-001 January 10, 2014 E2-3
RAI Question Number Type of Response (days)
Actual Date of Response FM 01, part g 90 Future letter FM 01, part h.i 60 CNL-14-001 January 10, 2014 FM 01, part h.ii 60 CNL-14-001 January 10, 2014 FM 01, part h.iii 90 Future letter FM 01, part i.i 120 Future letter FM 01, part i.ii 60 CNL-13-141 December 20, 2013 FM 01, part i.iii 90 CNL-14-001 January 10, 2014 FM 01, part i.iv 120 Future letter FM 01, part i.v 60 CNL-13-141 December 20, 2013 FM 01, part i.vi 60 CNL-13-141 December 20, 2013 FM 01, part i.vii 90 CNL-14-001 January 10, 2014 FM 01, part i.viii 60 CNL-13-141 December 20, 2013 FM 01, part j.i 60 CNL-13-141 December 20, 2013 FM 01, part j.ii 90 CNL-14-001 January 10, 2014 FM 02, part a 120 Future letter FM 02, part b 120 Future letter FM 02, part c 60 CNL-13-141 December 20, 2013 E2-4
RAI Question Number Type of Response (days)
Actual Date of Response FM 02, part d 60 CNL-13-141 December 20, 2013 FM 02, part e 90 Future letter FM 03 60 CNL-14-001 January 10, 2014 FM 04 90 Future letter FM 05 60 CNL-14-001 January 10, 2014 FM 06 60 CNL-14-001 January 10, 2014 Probabilistic Risk Assessment (PRA)
PRA 01, part a 60 CNL-14-001 January 10, 2014 PRA 01, part b 60 CNL-14-006 January 14, 2014 PRA 01, part c 90 CNL-14-001 January 10, 2014 PRA 01, part d 90 Future letter PRA 01, part e 120 Future letter PRA 01, part f 120 Future letter PRA 01, part g 60 CNL-14-001 January 10, 2014 PRA 01, part h 90 Future letter PRA 01, part i 60 CNL-13-141 December 20, 2013 PRA 01, part j 60 CNL-14-006 January 14, 2014 E2-5
RAI Question Number Type of Response (days)
Actual Date of Response PRA 01, part k 60 CNL-14-001 January 10, 2014 PRA 01, part l 60 CNL-14-006 January 14, 2014 PRA 01, part m 60 CNL-14-001 January 10, 2014 PRA 01, part n 60 CNL-14-001 January 10, 2014 PRA 01, part o 120 Future letter PRA 01, part p 90 Future letter PRA 01, part q 60 CNL-13-141 December 20, 2013 PRA 01, part r 60 CNL-13-141 December 20, 2013 PRA 01, part s 90 Future letter PRA 01, part t 60 CNL-14-001 January 10, 2014 PRA 01, part u 60 CNL-13-141 December 20, 2013 PRA 01, part v 120 Future letter PRA 02 60 CNL-14-001 January 10, 2014 PRA 03 60 CNL-13-141 December 20, 2013 PRA 04 90 Future letter PRA 05 60 (extended to 120 days per electronic mail from NRC to TVA, dated January 9, 2014)
Future letter E2-6
RAI Question Number Type of Response (days)
Actual Date of Response PRA 06 60 CNL-14-001 January 10, 2014 PRA 07 60 CNL-14-006 January 14, 2014 PRA 08 60 CNL-14-001 January 10, 2014 PRA 09 60 CNL-14-001 January 10, 2014 PRA 10 90 Future letter PRA 11 60 CNL-14-006 January 14, 2014 PRA 12 120 Future letter PRA 13 60 CNL-14-006 January 14, 2014 PRA 14 60 CNL-14-001 January 10, 2014 PRA 15 90 Future letter PRA 16 90 Future letter PRA 17 90 Future letter PRA 18 60 CNL-14-001 January 10, 2014 PRA 19 60 CNL-14-001 January 10, 2014 PRA 20 120 Future letter PRA 21 60 CNL-14-001 January 10, 2014 PRA 22 60 CNL-13-141 December 20, 2013 E2-7
RAI Question Number Type of Response (days)
Actual Date of Response PRA 23 60 (Part d extended to 120 days per electronic mail from NRC to TVA, dated January 9, 2014)
Parts c, f, i, and l:
CNL-14-001 January 10, 2014 Parts a, b, e, g, h, j, and k:
CNL-14-006 January 14, 2014 Part d: Future letter Radioactive Release (RR)
RR 01 60 (extended to 120 days per electronic mail from NRC to TVA, dated January 9, 2014)
Future letter RR 02 60 (extended to 120 days per electronic mail from NRC to TVA, dated January 9, 2014)
Future letter E2-8