May 24, 1990 Docket No. 50-206 DISTRIBUTION Docket File NRC & Local PDRs JTatum (2)

Mr. Harold B. Ray JZwolinski Vice President JLarkins Southern California Edison Company LA Irvine Operations Center OGC 23 Parker PD5 Plant File Irvine, California 92718 EJordan ACRS (10)

Dear Mr. Ray:

ESullivan

SUBJECT:

INSERVICE TESTING PROGRAM REQUIREMENTS FOR SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 74792)

The intent of Generic Letter 89-04 was to provide guidance in developing an acceptable inservice testing program. Additionally, it is the intent of the ASME Code,Section XI, that meaningful data be gathered and trended such that component degradation will be detected in advance of failure. Your methodology of testing the feedwater pumps does not provide individual flow rate information for each pump. Although we believe that measuring the combined flow rate of the feedwater pumps may provide an indication of significant hydraulic degrada tion, this methodology may not meet the Code intent of detecting meaningful deterioration before significant degradation and possible failure occurs.

Therefore, we request that you evaluate the possibility of performing inservice testing of the feedwater pumps on an individual basis. Reduced frequency testing as discussed in Generic Letter 89-04 may be acceptable.

Please notify us of the results of your evaluation.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under Pub. L.96-511.

Please contact us if you should have any questions regarding this request.

Sincerely, orignal signed by James Tatum James E. Tatum, Project Manager Project Directorate V

?5 Division of Reactor Projects - III, Ar R 65000206

~IV, V and Special Projects P

Office of Nuclear Reactor Regulation cc:

See next page

  • See previous concurrence NAME
PShea
JTatum:sg
ESullivan
JLarkins DATE
5/14/90
5/14/90
5/]8/90
5/H90 OFFICIAL RECORD COPY 0

Document Name:

SO 1 74792 N

v V

SREG0 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 May 24, 1990 Docket No. 50-206 Mr. Harold B. Ray Vice President Southern California Edison Company Irvine Operations Center 23 Parker Irvine, California 92718

Dear Mr. Ray:

SUBJECT:

INSERVICE TESTING PROGRAM REQUIREMENTS FOR SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 74792)

The intent of Generic Letter 89-04 was to provide guidance in developing an acceptable inservice testing program. Additionally, it is the intent of the ASME Code,Section XI, that meaningful data be gathered and trended such that component degradation will be detected in advance of failure. Your methodology of testing the feedwater pumps does not provide individual flow rate information for each pump. Although we believe that measuring the combined flow rate of the feedwater pumps may provide an indication of significant hydraulic degrada tion, this methodology may not meet the Code intent of detecting meaningful deterioration before significant degradation and possible failure occurs.

Therefore, we request that you evaluate the possibility of performing inservice testing of the feedwater pumps on an individual basis. Reduced frequency testing as discussed in Generic Letter 89-04 may be acceptable.

Please notify us of the results of your evaluation.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under Pub. L.96-511.

Please contact us if you should have any questions regarding this request.

Sincerely, J mes E. Tatum, Project Manager roject Directorate V Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc:

See next page

Mr. Harold B. Ray San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc David R. Pigott Mr. Richard J. Kosiba, Project Manager Orrick, Herrington & Sutcliffe Bechtel Power Corporation 600 Montgomery Street 12440 E. Imperial Highway San Francisco, California 94111 Norwalk, California 90650 Mr. Robert G. Lacy Mr. Phil Johnson Manager, Nuclear U.S. Nuclear Regulatory Commission San Diego Gas & Electric Company Region V P. 0. Box 1831 1450 Maria Lane, Suite 210 San Diego, California 92112 Walnut Creek, California 94596 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Management Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Mr. Don Womeldorf Chief, Environmental Management California Department of Health 714 P Street, Room 616 Sacramento, California 95814