August 10, 1990 Docket No. 50-206 Mr. Harold B. Ray Senior Vice President Southern California Edison Company Irvine Operations Center 23 Parker Irvine, California 92718

Dear Mr. Ray:

SUBJECT:

INSERVICE TESTING PROGRAM REQUIREMENTS FOR SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 74792)

The purpose of this letter is to inform you that we have completed our review associated with your response to Generic Letter 89-04, "Guidance on Developing Acceptable Inservice Testing Programs."

By letter dated April 6, 1990, we accepted your response to the generic letter and by letters dated May 18 and July 30, 1990, we provided our response to your requests for relief from ASME Code requirements. Therefore, we consider our actions to be complete.

As a result of our review, we identified that your methodology for testing the safety injection pumps, refueling water pumps and the feedwater pumps for San Onofre Unit 1 should be reconsidered in terms of obtaining more reliable and meaningful test data (NRC letters dated May 18 and May 24, 1990).

Should you determine that additional relief is required from ASME Code requirements as a result of your continuing evaluations regarding this matter, please contact us.

Sincerely, Oryna Signed By:

James E. Tatum, Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc:

See next page DISTRIBUTION Docket File NRC & Local PDRs B. Boger D. Foster OGC-WF PD5 Plant file E. Jordan B. Grimes ACRS(10)

J. Tatum(2)

J. Hayes, Jr.

E. Sullivan R. Zimmerman, RV DRSP/PD DR, D,

)D:PD5 DFoster JT1

. 1c J

-ns

/g

/90

/

/90 0' /90 DOCUMENLAME. SO ITPR 74792 90 0 1301 9c081 FER - DOC:K 05000:206 P

PDC_

Mr.'Harold B. Ray San Onofre Nuclear Generating Southern California Edison Company Station,. Unit No. 1 cc David R. Pigott Mr. Richard J. Kosiba, Project Manager Orrick, Herrington & Sutcliffe Bechtel Power Corporation 600 Montgomery Street 12440 E. Imperial Highway San Francisco, California 94111 Norwalk, California 90650 Mr. Robert G. Lacy Mr. Phil Johnson Manager, Nuclear U.S. Nuclear Regulatory Commission San Diego Gas & Electric Company Region V P. 0. Box 1831 1450 Maria Lane, Suite 210 San Diego, California 92112 Walnut Creek, California 94596 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Management Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Mr. Don Womeldorf Chief, Environmental Management California Department of Health 714 P Street, Room 616 Sacramento,-NCalifornia 95814