  • RINSC leu fuel cell Be XS 7/98 CELL 6 NPLATE 1 SEQUENCE 2 NGROUP 34 7 7 NMESH 13 13 NREGION 4 0 4 NMATERIAL 4 1 PREOUT LAST PRELUDE CARD INITITIATE 1st MAIN DATA CARD SLAB 1 3.04250 1 Fuel Region SLAB 2 3.88600 2 SidePlate SLAB 3 3.93533 3 water SLAB 4 7.77200 4 Be MESH 4 2 2 5 MATERIAL 1 -1 300.0 1 27 1.8593E-02 29 8.5470E-04 $

Fuel Zone 235.1 2.5240E-04 238.1 1.0126E-03 149 1.00E-20 $

135 1.000E-20 3239.1 1.000E-20 $

240.1 1.000E-20 241.1 1.000E-20 242.1 1.000E-20 $

1241.1 1.000E-20 1149 1.000E-20 2135 1.000E-20 $

236.1 1.00E-20 1238.1 1.000E-20 237.1 1.00E-20 $

10 6.4416E-08 11 2.6125E-07 2001 4.2824E-02 $

16 2.1412E-02 MATERIAL 2 -1 300.0 2 27 4.0765E-02 2001 2.1636E-02 $

sideplatead 16 1.0818E-02 MATERIAL 3 -1 300.0 3 2001 6.68610E-02 16 3.34305E-02 H2O MATERIAL 4 -1 300.0 4 12 8.5234E-02 Graphite FEWGROUPS 3 5 6 8 10 13 15 16 18 20 22 24 26 27 29 32 34 37 $

38 40 42 44 45 47 50 52 54 56 59 60 61 64 66 69 POWERC 1 519 0.0 1 BEGINC end of DATA OPTION 3 full edit BUCKLING 2.77E-03 2.33E-03 B-sq no eff on xs LEAKAGE 5 1 BEEONE 0 7 PARTITION 5 15 27 45 52 59 69 RR EDIT THERMAL 10 REGION 3 4 1 4 ISOXS 0 1 0 0 0 1 1 0 0 HUSE

RINSC isotxs HSETID RINSC LEU Graphite ISOTOPES 12 16 2001 ISONAMES GRAF G-O G-H EDITCELLS 0 0 1 1 VECTOR 2 7 14 23 26 29 34 relate FEWGROUPS BEGINC