STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS Rhode Island Atomic Energy Commission 16 Reactor Road Narragansett, Rl 02882-1165 Telephone # 401-874-2600 December 8, 2016 Docket No. 50-193 License No. R-95 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001
Subject:
Supplemental Information Re: Relicensing for the Rhode Island Nuclear Science Center (R-95)
Mr. Boyle, This letter and attachment contains supplemental information in support of the Rhode Island Nuclear Science Center's (RINSC's) relicensing effort. Our response includes 1 enclosure. The enclosure contains the facility's alpha, beta and gamma readings from our main floor monitor during our reactor run on December 1, 2016. On that day the reactor was operated from 0830 to 2040.
Ifthere are any questions regarding this matter, please feel free to contact me at (401) 874-2600.
Cameron Goodwin, PhD, Director Rhode Island Nuclear Science Center I certify under penalty of perjury that the representations made above are true and correct.
Executed on:
cc: A Adams Mr. Craig Bassett 5523 Preserve Point Flowery Branch, GA 30542 By: f---::"~2Z~~~;,,..L:..----C.------
1
12.01.16 Run Main Floor superTrend File Format 1: ARM: Float Table.MIRION-ABPM_MAIN_FL_R - Beta Rad (DAC) 2: ARM: Float Table.MIRION-ABPM_MAIN_FL_R - Alpha Rad (DAC) 3: ARM: Float Table.MIRION-ABPM_MAIN_FL_R -
Gamma mrad/Hr Pen pen Pen
//
PAC Display Historical
//
column 1: Pen ID
//
column 2: Date stamp
//
column 3: Time Stamp
//
column 4: scanned value
//////
1 12/01/2016 08:03:55.800 0.003 2 12/01/2016 08:03:55.800 0.100 3 12/01/2016 08:03:55.800 0.059 1 12/01/2016 08:08:55.800 0.003 2 12/01/2016 08:08:55.800 0.100 3 12/01/2016 08:08:55.800 0.059 1 12/01/2016 08:13:55.800 0.003 2 12/01/2016 08:13:55.800 0.100 3 12/01/2016 08:13:55.800 0.059 1 12/01/2016 08:18:55.800 0.003 2 12/01/2016 08:18:55.800 0.100 3 12/01/2016 08:18:55.800 0.059 1 12/01/2016 08:23:55.800 0.000 2 12/01/2016 08:23:55.800 0.000 3 12/01/2016 08:23:55.800 0.000 1 12/01/2016 08:28:55.800 0.003 2 12/01/2016 08:28:55.800 0.100 3 12/01/2016 08:28:55.800 0.024 1 12/01/2016 08:33:55.800 0.003 2 12/01/2016 08:33:55.800 0.100 3 12/01/2016 08:33:55.800 0.011 1 12/01/2016 08:38:55.800 0.003 2 12/01/2016 08:38:55.800 0.100 3 12/01/2016 08:38:55.800 0.011 1 12/01/2016 08:43:55.800 0.003 2 12/01/2016 08:43:55.800 0.100 3 12/01/2016 08:43:55.800 0.010 1 12/01/2016 08:48:55.800 0.003 2 12/01/2016 08:48:55.800 0.100 3 12/01/2016 08:48:55.800 0.020 1 12/01/2016 08:53:55.800 0.003 2 12/01/2016 08:53:55.800 0.100 3 12/01/2016 08:53:55.800 0.016 1 12/01/2016 08:58:55.800 0.003 2 12/01/2016 08:58:55.800 0.100 3 12/01/2016 08:58:55.800 0.013 1 12/01/2016 09:03:55.800 0.003 2 12/01/2016 09:03:55.800 0.100 3 12/01/2016 09:03:55.800 0.022 1 12/01/2016 09:08:55.800 0.003 2 12/01/2016 09:08:55.800 0.100 3 12/01/2016 09:08:55.800 0.029 1 12/01/2016 09:13:55.800 0.003 2 12/01/2016 09:13:55.800 0.100 3 12/01/2016 09:13:55.800 0.015 1 12/01/2016 09:18:55.800 0.003 2 12/01/2016 09:18:55.800 0.100 3 12/01/2016 09:18:55.800 0.043 1 12/01/2016 09:23:55.800 0.003 Page 1
12.01.16 Run Main Floor 2 12/01/2016 09:23:55.800 0.100 3 12/01/2016 09:23:55.800 0.943 1 12/01/2016 09:28:55.800 0.003 2 12/01/2016 09:28:55.800 0.100 3 12/01/2016 09:28:55.800 0.743 1 12/01/2016 09:33:55.800 0.003 2 12/01/2016 09:33:55.800 0.100 3 12/01/2016 09:33:55.800 0.759 1 12/01/2016 09:38:55.800 0.003 2 12/01/2016 09:38:55.800 0.100 3 12/01/2016 09:38:55.800 0.676 1 12/01/2016 09:43:55.800 0.003 2 12/01/2016 09:43:55.800 0.100 3 12/01/2016 09:43:55.800 0.893 1 12/01/2016 09:48:55.800 0.003 2 12/01/2016 09:48:55.800 0.100 3 12/01/2016 09:48:55.800 0.676 1 12/01/2016 09:53:55.800 0.003 2 12/01/2016 09:53:55.800 0.100 3 12/01/2016 09:53:55.800 0.659 1 12/01/2016 09:58:55.800 0.003 2 12/01/2016 09:58:55.800 0.100 3 12/01/2016 09:58:55.800 0.893 1 12/01/2016 10:03:55.800 0.003 2 12/01/2016 10:03:55.800 0.100 3 12/01/2016 10:03:55.800 0.859 1 12/01/2016 10:08:55.800 0.003 2 12/01/2016 10:08:55.800 0.100 3 12/01/2016 10:08:55.800 0.709 1 12/01/2016 10:13:55.800 0.003 2 12/01/2016 10:13:55.800 0.100 3 12/01/2016 10:13:55.800 0.859 1 12/01/2016 10:18:55.800 0.003 2 12/01/2016 10:18:55.800 0.100 3 12/01/2016 10:18:55.800 0.659 1 12/01/2016 10:23:55.800 0.003 2 12/01/2016 10:23:55.800 0.100 3 12/01/2016 10:23:55.800 0.909 1 12/01/2016 10:28:55.800 0.003 2 12/01/2016 10:28:55.800 0.100 3 12/01/2016 10:28:55.800 0.843 1 12/01/2016 10:33:55.800 0.003 2 12/01/2016 10:33:55.800 0.100 3 12/01/2016 10:33:55.800 0.626 1 12/01/2016 10:38:55.800 0.003 2 12/01/2016 10:38:55.800 0.100 3 12/01/2016 10:38:55.800 0.909 1 12/01/2016 10:43:55.800 0.004 2 12/01/2016 10:43:55.800 0.100 3 12/01/2016 10:43:55.800 0.809 1 12/01/2016 10:48:55.800 0.005 2 12/01/2016 10:48:55.800 0.100 3 12/01/2016 10:48:55.800 0.793 1 12/01/2016 10:53:55.800 0.007 2 12/01/2016 10:53:55.800 0.100 3 12/01/2016 10:53:55.800 0.809 1 12/01/2016 10:58:55.800 0.010 2 12/01/2016 10:58:55.800 0.100 3 12/01/2016 10:58:55.800 0.826 1 12/01/2016 11:03:55.800 0.041 2 12/01/2016 11:03:55.800 0.100 3 12/01/2016 11:03:55.800 0.743 1 12/01/2016 11:08:55.800 0.044 page 2
12.01.16 Run Main Floor 2 12/01/2016 11:08:55.800 0.100 3 12/01/2016 11:08:55.800 0.776 1 12/01/2016 11:13:55.800 0.045 2 12/01/2016 11:13:55.800 0.100 3 12/01/2016 11:13:55.800 0.943 1 12/01/2016 11:18:55.800 0.039 2 12/01/2016 11:18:55.800 0.100 3 12/01/2016 11:18:55.800 0.693 1 12/01/2016 11:23:55.800 0.043 2 12/01/2016 11:23:55.800 0.100 3 12/01/2016 11:23:55.800 0.959 1 12/01/2016 11:28:55.800 0.045 2 12/01/2016 11:28:55.800 0.100 3 12/01/2016 11:28:55.800 0.743 1 12/01/2016 11:33:55.800 0.045 2 12/01/2016 11:33:55.800 0.100 3 12/01/2016 11:33:55.800 0.926 1 12/01/2016 11:38:55.800 0.045 2 12/01/2016 11:38:55.800 0.100 3 12/01/2016 11:38:55.800 0.743 1 12/01/2016 11:43:55.800 0.043 2 12/01/2016 11:43:55.800 0.100 3 12/01/2016 11:43:59.800 0.909 1 12/01/2016 11:48:55.800 0.047 2 12/01/2016 11:48:55.800 0.100 3 12/01/2016 11:48:55.800 0.809 1 12/01/2016 11:53:55.800 0.046 2 12/01/2016 11:53:55.800 0.100 3 12/01/2016 11:53:55.800 0.826 1 12/01/2016 11:58:55.800 0.043 2 12/01/2016 11:58:55.800 0.100 3 12/01/2016 11:58:55.800 0.843 1 12/01/2016 12:03:55.800 0.040 2 12/01/2016 12:03:55.800 0.100 3 12/01/2016 12:03:55.800 0.926 1 12/01/2016 12:08:55.800 0.039 2 12/01/2016 12:08:55.800 0.100 3 12/01/2016 12:08:55.800 0.643 1 12/01/2016 12:13:55.800 0.042 2 12/01/2016 12:13:55.800 0.100 3 12/01/2016 12:13:55.800 0.793 1 12/01/2016 12:18:55.800 0.035 2 12/01/2016 12:18:55.800 0.100 3 12/01/2016 12:18:55.800 0.726 1 12/01/2016 12:23:55.800 0.032 2 12/01/2016 12:23:55.800 0.100 3 12/01/2016 12:23:55.800 0.776 1 12/01/2016 12:28:55.800 0.031 2 12/01/2016 12:28:55.800 0.100 3 12/01/2016 12:28:55.800 0.442 1 12/01/2016 12:33:55.800 0.030 2 12/01/2016 12:33:55.800 0.100 3 12/01/2016 12:33:55.800 0.442 1 12/01/2016 12:38:55.800 0.030 2 12/01/2016 12:38:55.800 0.100 3 12/01/2016 12:38:55.800 0.493 1 12/01/2016 12:43:55.800 0.029 2 12/01/2016 12:43:55.800 0.100 3 12/01/2016 12:43:55.800 0.526 1 12/01/2016 12:48:55.800 0.029 2 12/01/2016 12:48:55.800 0.100 3 12/01/2016 12:48:55.800 0.526 1 12/01/2016 12:53:55.800 0.026 Page 3
12.01.16 Run Main Floor 2 12/01/2016 12:53:55.800 0.100 3 12/01/2016 12:53:55.800 0.543 1 12/01/2016 12:58:55.800 0.030 2 12/01/2016 12:58:55.800 0.100 3 12/01/2016 12:58:55.800 0.576 1 12/01/2016 13:03:55.800 0.028 2 12/01/2016 13:03:55.800 0.100 3 12/01/2016 13:03:55.800 0.543 1 12/01/2016 13:08:55.800 0.025 2 12/01/2016 13:08:55.800 0.100 3 12/01/2016 13:08:55.800 0.543 1 12/01/2016 13:13:55.800 0.023 2 12/01/2016 13:13:55.800 0.100 3 12/01/2016 13:13:55.800 0.442 1 12/01/2016 13:18:55.800 0.022 2 12/01/2016 13:18:55.800 0.100 3 12/01/2016 13:18:55.800 0.459 1 12/01/2016 13:23:55.800 0.020 2 12/01/2016 13:23:55.800 0.100 3 12/01/2016 13:23:55.800 0.109 1 12/01/2016 13:28:55.800 0.018 2 12/01/2016 13:28:55.800 0.100 3 12/01/2016 13:28:55.800 0.093 1 12/01/2016 13:33:55.800 0.018 2 12/01/2016 13:33:55.800 0.100 3 12/01/2016 13:33:55.800 0.109 1 12/01/2016 13:38:55.816 0.017 2 12/01/2016 13:38:55.816 0.100 3 12/01/2016 13:38:55.816 0.076 1 12/01/2016 13:43:55.800 0.015 2 12/01/2016 13:43:55.800 0.100 3 12/01/2016 13:43:55.800 0.126 1 12/01/2016 13:48:55.800 0.013 2 12/01/2016 13:48:55.800 0.100 3 12/01/2016 13:48:55.800 0.065 1 12/01/2016 13:53:55.800 0.011 2 12/01/2016 13:53:55.800 0.100 3 12/01/2016 13:53:55.800 0.593 1 12/01/2016 13:58:55.800 0.008 2 12/01/2016 13:58:55.800 0.100 3 12/01/2016 13:58:55.800 0.743 1 12/01/2016 14:03:55.800 0.006 2 12/01/2016 14:03:55.800 0.100 3 12/01/2016 14:03:55.800 0.759 1 12/01/2016 14:08:55.800 0.003 2 12/01/2016 14:08:55.800 0.100 3 12/01/2016 14:08:55.800 0.759 1 12/01/2016 14:13:55.800 0.003 2 12/01/2016 14:13:55.800 0.100 3 12/01/2016 14:13:55.800 0.693 1 12/01/2016 14:18:55.800 0.003 2 12/01/2016 14:18:55.800 0.100 3 12/01/2016 14:18:55.800 0.843 1 12/01/2016 14:23:55.800 0.003 2 12/01/2016 14:23:55.800 0.100 3 12/01/2016 14:23:55.800 0.609 1 12/01/2016 14:28:55.800 0.003 2 12/01/2016 14:28:55.800 0.100 3 12/01/2016 14:28:55.800 0.893 1 12/01/2016 14:33:55.800 0.003 2 12/01/2016 14:33:55.800 0.100 3 12/01/2016 14:33:55.800 0.709 1 12/01/2016 14:38:55.800 0.003 Page 4
12.01.16 Run Main Floor 2 12/01/2016 14:38:55.800 0.100 3 12/01/2016 14:38:55.800 0.709 1 12/01/2016 14:43:55.800 0.003 2 12/01/2016 14:43:55.800 0.100 3 12/01/2016 14:43:55.800 0.876 1 12/01/2016 14:48:55.800 0.003 2 12/01/2016 14:48:55.800 0.100 3 12/01/2016 14:48:55.800 0.876 1 12/01/2016 14:53:55.800 0.003 2 12/01/2016 14:53:55.800 0.100 3 12/01/2016 14:53:55.800 0.893 1 12/01/2016 14:58:55.800 0.003 2 12/01/2016 14:58:55.800 0.100 3 12/01/2016 14:58:55.800 0.809 1 12/01/2016 15:03:55.800 0.003 2 12/01/2016 15:03:55.800 0.100 3 12/01/2016 15:03:55.800 0.743 1 12/01/2016 15:08:55.800 0.003 2 12/01/2016 15:08:55.800 0.100 3 12/01/2016 15:08:55.800 0.593 1 12/01/2016 15:13:55.800 0.003 2 12/01/2016 15:13:55.800 0.100 3 12/01/2016 15:13:55.800 0.809 1 12/01/2016 15:18:55.800 0.003 2 12/01/2016 15:18:55.800 0.100 3 12/01/2016 15:18:55.800 0.709 1 12/01/2016 15:23:55.800 0.003 2 12/01/2016 15:23:55.800 0.100 3 12/01/2016 15:23:55.800 0.659 1 12/01/2016 15:28:55.800 0.003 2 12/01/2016 15:28:55.800 0.100 3 12/01/2016 15:28:55.800 0.843 1 12/01/2016 15:33:55.800 0.003 2 12/01/2016 15:33:55.800 0.100 3 12/01/2016 15:33:55.800 0.526 1 12/01/2016 15:38:55.800 0.003 2 12/01/2016 15:38:55.800 0.100 3 12/01/2016 15:38:55.800 0.626 1 12/01/2016 15:43:55.800 0.003 2 12/01/2016 15:43:55.800 0.100 3 12/01/2016 15:43:55.800 0.793 1 12/01/2016 15:48:55.800 0.003 2 12/01/2016 15:48:55.800 0.100 3 12/01/2016 15:48:55.800 0.609 1 12/01/2016 15:53:55.800 0.003 2 12/01/2016 15:53:55.800 0.100 3 12/01/2016 15:53:55.800 0.576 1 12/01/2016 15:58:55.800 0.003 2 12/01/2016 15:58:55.800 0.100 3 12/01/2016 15:58:55.800 0.759 1 12/01/2016 16:03:55.800 0.003 2 12/01/2016 16:03:55.800 0.100 3 12/01/2016 16:03:55.800 0.726 1 12/01/2016 16:08:55.800 0.003 2 12/01/2016 16:08:55.800 0.100 3 12/01/2016 16:08:55.800 0.576 1 12/01/2016 16:13:55.800 0.003 2 12/01/2016 16:13:55.800 0.100 3 12/01/2016 16:13:55.800 0.709 1 12/01/2016 16:18:55.800 0.003 2 12/01/2016 16:18:55.800 0.100 3 12/01/2016 16:18:55.800 0.876 1 12/01/2016 16:23:55.800 0.003 Page 5
12.01.16 Run Main Floor 2 12/01/2016 16:23:55.800 0.100 3 12/01/2016 16:23:55.800 0.759 1 12/01/2016 16:28:55.800 0.003 2 12/01/2016 16:28:55.800 0.100 3 12/01/2016 16:28:55.800 0.776 1 12/01/2016 16:33:55.800 0.003 2 12/01/2016 16:33:55.800 0.100 3 12/01/2016 16:33:55.800 0.659 1 12/01/2016 16:38:55.800 0.003 2 12/01/2016 16:38:55.800 0.100 3 12/01/2016 16:38:55.800 0.676 1 12/01/2016 16:43:55.800 0.003 2 12/01/2016 16:43:55.800 0.100 3 12/01/2016 16:43:55.800 0.776 1 12/01/2016 16:48:55.800 0.003 2 12/01/2016 16:48:55.800 0.100 3 12/01/2016 16:48:55.800 0.659 1 12/01/2016 16:53:55.800 0.003 2 12/01/2016 16:53:55.800 0.100 3 12/01/2016 16:53:55.800 0.643 1 12/01/2016 16:58:55.800 0.003 2 12/01/2016 16:58:55.800 0.100 3 12/01/2016 16:58:55.800 0.776 1 12/01/2016 17:03:55.800 0.003 2 12/01/2016 17:03:55.800 0.100 3 12/01/2016 17:03:55.800 0.743 1 12/01/2016 17:08:55.800 0.003 2 12/01/2016 17:08:55.800 0.100 3 12/01/2016 17:08:55.800 0.776 1 12/01/2016 17:13:55.800 0.003 2 12/01/2016 17:13:55.800 0.100 3 12/01/2016 17:13:55.800 0.776 1 12/01/2016 17:18:55.800 0.003 2 12/01/2016 17:18:55.800 0.100 3 12/01/2016 17:18:55.800 0.709 1 12/01/2016 17:23:55.800 0.003 2 12/01/2016 17:23:55.800 0.100 3 12/01/2016 17:23:55.800 0.843 1 12/01/2016 17:28:55.800 0.003 2 12/01/2016 17:28:55.800 0.100 3 12/01/2016 17:28:55.800 0.559 1 12/01/2016 17:33:55.800 0.003 2 12/01/2016 17:33:55.800 0.100 3 12/01/2016 17:33:55.800 0.659 1 12/01/2016 17:38:55.800 0.003 2 12/01/2016 17:38:55.800 0.100 3 12/01/2016 17:38:55.800 0.676 1 12/01/2016 17:43:55.800 0.003 2 12/01/2016 17:43:55.800 0.100 3 12/01/2016 17:43:55.800 0.609 1 12/01/2016 17:48:55.800 0.003 2 12/01/2016 17:48:55.800 0.100 3 12/01/2016 17:48:55.800 0.809 1 12/01/2016 17:53:55.800 0.003 2 12/01/2016 17:53:55.800 0.100 3 12/01/2016 17:53:55.800 0.926 1 12/01/2016 17:58:55.800 0.003 2 12/01/2016 17:58:55.800 0.100 3 12/01/2016 17:58:55.800 0.743 1 12/01/2016 18:03:55.800 0.003 2 12/01/2016 18:03:55.800 0.100 3 12/01/2016 18:03:55.800 0.626 1 12/01/2016 18:08:55.800 0.003 Page 6
12.01.16 Run Main Floor 2 12/01/2016 18:08:55.800 0.100 3 12/01/2016 18:08:55.800 0.859 1 12/01/2016 18:13:55.800 0.003 2 12/01/2016 18:13:55.800 0.100 3 12/01/2016 18:13:55.800 0.643 1 12/01/2016 18:18:55.800 0.003 2 12/01/2016 18:18:55.800 0.100 3 12/01/2016 18:18:55.800 0.626 1 12/01/2016 18:23:55.800 0.003 2 12/01/2016 18:23:55.800 0.100 3 12/01/2016 18:23:55.800 0.643 1 12/01/2016 18:28:55.800 0.003 2 12/01/2016 18:28:55.800 0.100 3 12/01/2016 18:28:55.800 0.693 1 12/01/2016 18:33:55.800 0.003 2 12/01/2016 18:33:55.800 0.100 3 12/01/2016 18:33:55.800 0.659 1 12/01/2016 18:38:55.800 0.003 2 12/01/2016 18:38:55.800 0.100 3 12/01/2016 18:38:55.800 0.559 1 12/01/2016 18:43:55.800 0.003 2 12/01/2016 18:43:55.800 0.100 3 12/01/2016 18:43:55.800 0.659 1 12/01/2016 18:48:55.800 0.003 2 12/01/2016 18:48:55.800 0.100 3 12/01/2016 18:48:55.800 0.626 1 12/01/2016 18:53:55.800 0.003 2 12/01/2016 18:53:55.800 0.100 3 12/01/2016 18:53:55.800 0.709 1 12/01/2016 18:58:55.800 0.003 2 12/01/2016 18:58:55.800 0.100 3 12/01/2016 18:58:55.800 0.709 1 12/01/2016 19:03:55.800 0.003 2 12/01/2016 19:03:55.800 0.100 3 12/01/2016 19:03:55.800 0.826 1 12/01/2016 19:08:55.800 0.003 2 12/01/2016 19:08:55.800 0.100 3 12/01/2016 19:08:55.800 0.676 1 12/01/2016 19:13:55.800 0.003 2 12/01/2016 19:13:55.800 0.100 3 12/01/2016 19:13:55.800 0.609 1 12/01/2016 19:18:55.800 0.003 2 12/01/2016 19:18:55.800 0.100 3 12/01/2016 19:18:55.800 0.709 1 12/01/2016 19:23:55.800 0.003 2 12/01/2016 19:23:55.800 0.100 3 12/01/2016 19:23:55.800 0.576 1 12/01/2016 19:28:55.800 0.003 2 12/01/2016 19:28:55.800 0.100 3 12/01/2016 19:28:55.800 0.843 1 12/01/2016 19:33:55.800 0.003 2 12/01/2016 19:33:55.800 0.100 3 12/01/2016 19:33:55.800 0.593 1 12/01/2016 19:38:55.800 0.003 2 12/01/2016 19:38:55.800 0.100 3 12/01/2016 19:38:55.800 0.709 1 12/01/2016 19:43:55.800 0.003 2 12/01/2016 19:43:55.800 0.111 3 12/01/2016 19:43:55.800 0.659 1 12/01/2016 19:48:55.800 0.003 2 12/01/2016 19:48:55.800 0.107 3 12/01/2016 19:48:55.800 0.743 1 12/01/2016 19:53:55.800 0.003 Page 7
12.01.16 Run Main Floor 2 12/01/2016 19:53:55.800 0.115 3 12/01/2016 19:53:55.800 1.026 1 12/01/2016 19:58:55.800 0.003 2 12/01/2016 19:58:55.800 0.102 3 12/01/2016 19:58:55.800 0.693 1 12/01/2016 20:03:55.800 0.003 2 12/01/2016 20:03:55.800 0.107 3 12/01/2016 20:03:55.800 0.126 1 12/01/2016 20:08:55.800 0.003 2 12/01/2016 20:08:55.800 0.100 3 12/01/2016 20:08:55.800 0.142 1 12/01/2016 20:13:55.800 0.003 2 12/01/2016 20:13:55.800 0.100 3 12/01/2016 20:13:55.800 0.126 1 12/01/2016 20:18:55.800 0.003 2 12/01/2016 20:18:55.800 0.100 3 12/01/2016 20:18:55.800 0.126 1 12/01/2016 20:23:55.800 0.003 2 12/01/2016 20:23:55.800 0.100 3 12/01/2016 20:23:55.800 0.126 1 12/01/2016 20:28:55.800 0.003 2 12/01/2016 20:28:55.800 0.100 3 12/01/2016 20:28:55.800 0.126 1 12/01/2016 20:33:55.800 0.003 2 12/01/2016 20:33:55.800 0.100 3 12/01/2016 20:33:55.800 0.126 1 12/01/2016 20:38:55.800 0.003 2 12/01/2016 20:38:55.800 0.100 3 12/01/2016 20:38:55.800 0.126 1 12/01/2016 20:43:55.800 0.003 2 12/01/2016 20:43:55.800 0.100 3 12/01/2016 20:43:55.800 0.126 1 12/01/2016 20:48:55.800 0.003 2 12/01/2016 20:48:55.800 0.100 3 12/01/2016 20:48:55.800 0.126 1 12/01/2016 20:53:55.800 0.003 2 12/01/2016 20:53:55.800 0.100 3 12/01/2016 20:53:55.800 0.126 1 12/01/2016 20:58:55.816 0.003 2 12/01/2016 20:58:55.816 0.100 3 12/01/2016 20:58:55.816 0.126 Rx Shut Down.
Page 8