E-mail from R.Guzman to W.Lobo Acceptance Review Determination - Request for Alternative - Risk Based Inservice Inspection
ML13123A463
Person / Time
Site: Pilgrim
Issue date: 05/03/2013
From: Richard Guzman
Plant Licensing Branch 1
To: Lobo W
Entergy Nuclear Operations
Guzman R
References
TAC ME1428
Download: ML13123A463 (1)


Text

From: Guzman, Richard Sent: Friday, May 03, 2013 6:51 PM To:

'wlobo@entergy.com' Cc:

'Williams, Murray'

Subject:

RE: PNPS Letter 2.13.030 - Request for Alternative - Risk Based Inservice Inspection - ACCEPTANCE REVIEW DETERMINATION (TAC No. MF1428)

Walter, The purpose of this e-mail is to provide the results of the NRC staffs acceptance review dated April 10, 2013 (ADAMS Accession No. ML13114A053). The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed the application and concludes that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment.

This message will be added to ADAMS as an official agency record. If you have any questions, please contact me.

Rich Guzman Sr. Project Manager NRR/DORL/LPL1-1 US NRC 301-415-1030


Original Message-----

From: Williams, Murray [1]

Sent: Thursday, April 11, 2013 4:49 PM To: Guzman, Richard

Subject:

PNPS Letter 2.13.030 - Request for Alternative - Risk Based Inservice Inspection Mr. Guzman, Attached is a copy of the letter transmitting a Request for Alternative

- Risk Based Inservice Inspection (PNPS Relief Request PRR-22). The hard copy will follow in the mail. I wanted to

make sure that you were aware of the request prior to others receiving a copy.

Murray Williams Senior Licensing Specialist Pilgrim Nuclear Power Station (508) 830-8275