ML12307A397

From kanterella
Jump to navigation Jump to search
301 Final RO Written Exam
ML12307A397
Person / Time
Site: Catawba  Duke Energy icon.png
Issue date: 11/01/2012
From:
NRC/RGN-II
To:
References
Download: ML12307A397 (77)


Text

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 1 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 1 With Unit 1 at 90% power the following conditions exist:

RPS Testing is in progress.

Reactor Trip Breaker A (RTA) is CLOSED.

Reactor Trip Breaker B (RTB) is OPEN.

Reactor Trip Bypass Breaker B (BYB) is Racked In to CONN and CLOSED.

During the testing the following occurs:

The A NC Pump Shaft seizes.

A MANUAL trip of the reactor was required and was SUCCESSFUL.

Which ONE of the following identifies the Reactor Trip/Bypass Breaker trip coil that operated AS DESIGNED throughout the event?

A.

RTA Undervoltage Coil B.

RTA Shunt Trip Coil C.

BYB Undervoltage Coil D.

BYB Shunt Trip Coil

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 2 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 2 Given the following Unit 1 conditions:

Initial:

The Unit was at 70% power when 1NC-32B (PZR PORV) began leaking.

1NC-31B (PZR Power Relief Isolation) was CLOSED to isolate the leak.

Subsequent:

1NC-34A (PZR PORV) comes off its valve seat and begins leaking by.

Pressurizer Relief Tank pressure and level are increasing.

The crew enters AP/1/A/5500/011, (Pressurizer Pressure Anomalies).

Which ONE of the following describes the required operation for closing 1NC-33A (PZR Power Relief Isolation)?

A.

Select control switch for 1NC-33A to CLOSE only.

B.

Select control switch for 1NC-31B to OVERRIDE and then select control switch for 1NC-33A to CLOSE.

C.

Select control switch for 1NC-31B to OVERRIDE and then select control switch for 1NC-33A to OVERRIDE.

D.

Select control switch for 1NC-33A to OVERRIDE only.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 3 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 3 Given the following Unit 1 conditions:

Initial:

The Unit is at 100% power.

1B NV Pump is tagged out for motor replacement.

Subsequent:

A Small Break LOCA occurs.

Containment pressure peaks at 2.3 psig.

Current:

NC pressure is 1650 psig and stable.

Core Exit Thermocouples are 750°F.

RVLIS Level is 70% Upper Range and slowly decreasing.

S/G levels are all ~30% and stable.

Main Steam pressure is 1085 psig and stable.

1ETA is DEENERGIZED.

Containment pressure is 1.8 psig and slowly decreasing.

(1) What is the current mechanism/method for cooling?

(2) In accordance with FR-C.2, (Response to Degraded Core Cooling), what is the next required action?

A.

(1) Safety injection flow (2) Dump steam to the condenser.

B.

(1) Reflux cooling (2) Depressurize the NC system by opening one PZR PORV.

C. (1) Safety injection flow (2) Depressurize the NC system by opening one PZR PORV.

D. (1) Reflux cooling (2) Dump steam to the condenser.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 4 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 4 Given the following Unit 1 initial conditions:

The Unit is cooling down for a refueling outage.

NC Thots are at 365ºF.

NC pressure is 120 psig.

All CLAs have been isolated.

Subsequently:

Pressurizer pressure and level are steadily decreasing.

Containment pressure is increasing.

The crew enters AP/1/A/5500/027, (Shutdown LOCA) and maximizes charging and isolates letdown.

Pressurizer level and pressure continue to decrease.

Which ONE of the following describes the requirements for cooldown?

(1) In accordance with AP/27, the recommended cooldown rate is LESS THAN _____(1)_____

in one hour.

(2) In accordance with OP/1/A/6200/004, (Residual Heat Removal System), which ONE of the following NC temperatures is the EARLIEST at which the ND system can be operated in RHR mode?

A.

(1) 100ºF (2) 340ºF B.

(1) 80ºF (2) 340ºF C. (1) 100ºF (2) 300ºF D. (1) 80ºF (2) 300ºF

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 5 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 5 Given the following Unit 1 conditions:

The Unit is at 41% power.

1D NCP (Reactor Coolant Pump) trips.

Which ONE of the following describes:

(1) How 1D Steam Generator level indications are INITIALLY affected?

(2) The effect of the NCP trip on reactor status?

A.

(1) Decrease (2) Automatic reactor trip occurs.

B.

(1) Decrease (2) A manual reactor trip is required.

C. (1) Increase (2) Automatic reactor trip occurs.

D. (1) Increase (2) A manual reactor trip is required.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 6 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 6 In accordance with AP/1/A/5500/008 (Malfunction of Reactor Coolant Pump), if the ____(1)____

seal leakoff flow is ____(2)____, then the pump must be tripped within 5 minutes.

(Assume Unit is in Mode 3.)

A.

(1) #1 (2) > 1.1 gpm B.

(1) #1 (2) > 7.5 gpm C. (1) #2 (2) > 1.1 gpm D. (1) #2 (2) > 7.5 gpm

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 7 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 7 Assume Unit 1 ND is aligned in RHR Mode.

If relief valve _______(1)_______ fails full OPEN, the A and B level indicators on 1MC-11 for the Containment Floor and Equipment Sump will begin to increase

___________(2)____________ after the valve failure.

Which ONE of the following completes the above statement?

A.

(1) 1ND-3, (1A ND Train Suction Relief)

(2) within a few seconds B.

(1) 1ND-3, (1A ND Train Suction Relief)

(2) approximately 5 minutes C.

(1) 1ND-31, (1A ND Pump Discharge Relief)

(2) within a few seconds D.

(1) 1ND-31, (1A ND Pump Discharge Relief)

(2) approximately 5 minutes

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 8 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 8 In accordance with FR-S.1, (Response to Nuclear Power Generation/ATWS), Step 8 (Verify reactor is subcritical), which Nuclear Instrumentation is used in the steps for verifying that the reactor is subcritical, and why is it used?

(1)

The _________(1)___________ Nuclear Instrumentation is used.

(2)

The purpose of using this instrumentation is to verify that ______(2)_______.

A.

(1) Wide Range (2) Reactor power is less than 5%.

B.

(1) Intermediate Range (2) Startup rate is more negative than (-) 0.2 dpm.

C. (1) Intermediate Range (2) Reactor power is less than 1.00E-05%.

D. (1) Source Range (2) Startup rate is more negative than (-) 0.2 dpm.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 9 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 9 During the performance of FR-H.1 (Response to Loss of Secondary Heat Sink) all conditions have been met for establishing feed flow to the S/Gs using Enclosure 7 (S/G CM/CF Flow Restoration).

S/G Wide Range (WR) levels are:

1A S/G = 9%

1B S/G = 1%

1C S/G = 6%

1D S/G = 10%

In accordance with FR-H.1, Enclosure 7, feeding the S/G with the ______(1)______ level will reduce the risk of _____________(2)_____________ when reestablishing feed flow.

Which ONE of the following completes the above statement?

A.

(1) lowest (2) thermal shock to the S/G B.

(1) lowest (2) excessive NC system cooldown C. (1) highest (2) thermal shock to the S/G D. (1) highest (2) excessive NC system cooldown

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 10 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 10 Following a Loss of Offsite Power, the crew is preparing to transfer 1FTA's power supply from the ALTERNATE source back to the NORMAL source, using the Hot Bus Transfer method.

Which ONE of the following describes how this operation is performed in accordance with OP/1/A/6350/005, (Alternate AC Power Sources)?

A.

With 1A D/G engine running, the operator selects "D/G 1A SYNC" switch on 1MC-11 to "ON". When the indicator is 1.5 minutes from vertical, close the D/G output breaker, and then close normal feeder breaker GTA.

B.

With 1A D/G engine running, the operator selects "D/G 1A SYNC" switch on 1MC-11 to "ON". When indicator is 1.5 minutes from vertical, close ONLY the normal feeder breaker GTA.

C.

With 1A D/G engine NOT running, "D/G 1A SYNC" switch on 1MC-11 is verified "OFF."

Then close GTA and then manually open ETA-2 and FTA-1.

D.

With 1A D/G engine NOT running, "D/G 1A SYNC" switch on 1MC-11 is selected to "ON."

Then close GTA and verify ETA-2 and FTA-1 have automatically opened.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 11 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 11 Given the following Unit 1 conditions:

The Unit is at 100% power.

Subsequently:

The following alarms are received:

1AD-11, I/4, (240/120VAC NORM AUX CONTROL PWR TROUBLE) 1AD-2, F/10, (DCS TROUBLE)

The crew has entered AP/1/A/5500/029, (Loss of Vital or Aux Control Power).

It has been determined that more than one Distributed Control System (DCS) Controller Drop has lost power.

If DCS Controller Drop ____(1)____ AND DCS Controller Drop ____(2)____ have experienced the loss of power, immediate entry into T.S. 3.0.3 is required.

Which ONE of the following completes the above statement?

Reference Provided A.

(1) 6/56 (2) 7/57 B.

(1) 6/56 (2) 8/58 C. (1) 8/58 (2) 12/62 D. (1) 7/57 (2) 8/58

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 12 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 12 Given the following Unit 1 initial conditions:

The Unit is at 100% power.

NV Pump 1B is tagged out for maintenance.

Subsequent:

A loss of RN occurs and the crew is implementing AP/0/A/5500/020 (Loss of Nuclear Service Water).

The loss of RN has affected the KC System such that NV pump motor cooling has been lost.

The crew is implementing AP/020, Enclosure 12 (Alternate Cooling to NV Pump 1A).

(1) In accordance with AP/020, if the alternate cooling water to NV Pump 1A is not established within ___(1)___ minutes, the thrust bearing will experience high temperature conditions.

(2) Once the alternate cooling water flow is established, Enclosure 12 directs that it be throttled to a minimum to maintain bearing temperatures at just below the high temperature limit.

This is done in order to ______________________(2)________________________.

A.

(1) 15 (2) minimize the generation of liquid radwaste B.

(1) 15 (2) prevent thermal shocking of the thrust bearing C. (1) 5 (2) minimize the generation of liquid radwaste D. (1) 5 (2) prevent thermal shocking of the thrust bearing

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 13 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 13 For a Loss of Instrument Air event, which ONE of the following completes the statements below?

(1) The reason for the CA accumulators is to provide a backup supply of operating air to the CA flow control valve actuators for a MINIMUM of _____________(1)_______________.

(2) The purpose for this feature is to protect from

________________(2)____________________ with a Loss of VI.

A.

(1) 30 minutes (2) runout of the CA pumps during a Main Feedwater Line Rupture B.

(1) 30 minutes (2) S/G overfill during a S/G Tube Rupture C. (1) 60 minutes (2) runout of the CA pumps during a Main Feedwater Line Rupture D. (1) 60 minutes (2) S/G overfill during a S/G Tube Rupture

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 14 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 14 Given the following Unit 1 conditions:

The Unit is at 100% power.

A grid disturbance occurs resulting in a Zone B lockout.

Which ONE of the following describes an expected alarm, and which automatic turbine runback will be in progress?

A.

(1) 1AD-11, C/1, (GEN BKR A OVERCURRENT)

(2) Runback to 48%

B.

(1) 1AD-11, F/1, (GEN BKR B OVERCURRENT)

(2) Runback to 48%

C. (1) 1AD-11, C/1, (GEN BKR A OVERCURRENT)

(2) Runback to 65%

D. (1) 1AD-11, F/1, (GEN BKR B OVERCURRENT)

(2) Runback to 65%

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 15 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 15 When performing ECA-1.2, (LOCA Outside Containment), why is the ND system alignment addressed EARLIER in the procedure than other ECCS equipment?

A.

To maintain suction to the charging pumps if containment sump swapover has already occurred.

B.

This allows the charging pumps to maintain NC Pump seal injection.

C.

Isolation of ND components requires manipulations outside the control room.

D.

The leak is most likely to occur in the ND system.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 16 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 16 (Assume containment pressure in each Unit is 1.2 psig.)

(1)

When determining entry conditions for FR-H.1 (Response to Loss of Secondary Heat Sink), the ______(1)______ range indication for S/G levels is used.

(2)

In accordance with FR-H.1, the level requirement for S/G levels for Unit 1 is

______(2)______ than for Unit 2.

A.

(1) narrow (2) higher B.

(1) narrow (2) lower C. (1) wide (2) higher D. (1) wide (2) lower

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 17 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 17 Which ONE of the following describes the method of depressurizing the S/Gs to support CLA injection, in accordance with ECA-1.1 (Loss of Emergency Coolant Recirculation)?

A.

Slowly until S/G pressures are < 690 psig, then at the maximum rate until S/G pressures are < 125 psig.

B.

Slowly until at least two NC Thots are < 356°F, then at the maximum rate until S/G pressures are < 125 psig.

C. At the maximum rate while attempting to avoid Main Steam Isolation until at least two NC Thots are < 356°F, then slowly until S/G pressures are < 125 psig.

D. At the maximum rate while attempting to avoid Main Steam Isolation until S/G pressures are < 690 psig, then slowly until S/G pressures are < 125 psig.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 18 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 18 During the performance of ECA-2.1, (Uncontrolled Depressurization of All Steam Generators) the following conditions exist:

  • The operators have requested NC boron samples from Primary Chemistry.
  • The actions of Step 6 (minimizing NC system cooldown) have just been initiated.

(1)

The operators _____(1)_____ required to obtain boron sample results PRIOR to initiating a controlled cooldown.

(2)

In accordance with ECA-2.1, Enclosure 1 (Foldout Page), IF the pressure in any S/G increases, AND S/I termination ___________(2)___________, then the crew will GO TO E-2, (Faulted Steam Generator Isolation).

In accordance with ECA-2.1, which ONE of the following completes the above statements?

A.

(1) are (2) is in progress B.

(1) are NOT (2) is in progress C.

(1) are (2) has been completed D.

(1) are NOT (2) has been completed

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 19 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 19 Given the following conditions:

With Unit 1 initially at 100% power, Bank A rod H-6 dropped fully into the core.

AP/14, (Control Rod Misalignment) Case II, "Dropped Control Rod" was entered.

Dropped rod recovery is in progress, in accordance with OP/1/A/6150/008, (Rod Control), Enclosure 4.6, "Rod Retrieval".

The operators have ensured that the lift coils are in the required configuration for all rods in the affected bank (rods H-6, K-8, F-8, and H-10).

(1) When the OATC operates the "ROD MOTION" lever, a "ROD CONTROL URGENT FAILURE" alarm ______(1)_____ be received.

(2) Whenever a "ROD CONTROL URGENT FAILURE" alarm is received, a manual RESET is performed by depressing the "ROD CTRL ALARM RESET" pushbutton for

_______(2)________ before releasing it, in accordance with OP/1/A/6150/008.

Which ONE of the following completes the above statements?

A.

(1) WILL (2) no more than ONE second B.

(1) WILL (2) at least TWO seconds C. (1) will NOT (2) no more than ONE second D. (1) will NOT (2) at least TWO seconds

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 20 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 20 Given the following Unit 1 conditions:

The Unit is at 100% power.

While performing the RCCA movement test, Bank D control rod H-8 remains at 198 steps withdrawn.

All other Bank D control rods (D4, M12, D12, M4) are at 212 steps withdrawn as indicated on DRPI and step demand counters.

(1) What is the maximum time allowed to restore rod H-8 to within limits per Technical Specification 3.1.4 (Rod Group Alignment Limits)?

(2) In accordance with OP/1/A/6150/008 (Rod Control), in the Control Rod Disconnect Switch Box on 1MC5, which switch, or switches, will be operated when initially attempting to restore the required rod alignment?

A.

(1) 30 minutes (2) Switch labeled "H8" ONLY B.

(1) 30 minutes (2) Switches labeled "D4" and "M12" and "D12" and "M4" C. (1) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (2) Switch labeled "H8" ONLY D. (1) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (2) Switches labeled "D4" and "M12" and "D12" and "M4"

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 21 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 21 Unit 1 was operating at 100% power when a turbine trip occurred.

Given the following conditions and sequence of events:

The reactor did not trip and could NOT be tripped from the control room.

Pressurizer pressure is 2340 psig.

The crew entered EP/1/A/5000/E-0, (Reactor Trip or Safety Injection) and immediately transitioned to EP/1/A/5000/FR-S.1, (Response to Nuclear Power Generation/ATWS).

The crew is initiating emergency boration.

1NV-236B (Boric Acid to NV Pump Suct) is opened.

Boric acid transfer pump switches are in ON.

1NV-312A and 1NV-314B (Chrg Line Cont Isol) are OPEN.

(1) In accordance with FR-S.1, what is the required action?

(2) The reason for that action is to ensure that EMERGENCY BORATION is provided to the core at a MINIMUM of __________ ?

A.

(1) Manually actuate safety injection.

(2) 30 gpm B.

(1) Depressurize the NC system to less than 2135 psig using Pressurizer PORVs.

(2) 60 gpm C. (1) Manually actuate safety injection.

(2) 60 gpm D. (1) Depressurize the NC system to less than 2135 psig using Pressurizer PORVs.

(2) 30 gpm

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 22 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 22 Given the following Unit 1 conditions:

The Unit is in Mode 2 conducting a reactor startup following a refueling outage.

N-31 (Source Range) indicates 4.0x102 cps.

N-32 (Source Range) indicates 5.0x101 cps.

N-35 (Intermediate Range) indicates 10-6% power.

N-36 (Intermediate Range) indicates 10-6% power.

Both reactor trip breakers are closed.

The rod control system is capable of rod withdrawal.

Which ONE of the following describes:

(1)

Which Source Range instruments are indicating properly?

(2)

What immediate action is required in accordance with Technical Specifications?

A.

(1) NEITHER (2) Open both reactor trip breakers.

B.

(1) ONLY N-31 (2) Open both reactor trip breakers.

C. (1) NEITHER (2) Suspend positive reactivity additions.

D. (1) ONLY N-31 (2) Suspend positive reactivity additions.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 23 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 23 Given the following Unit 2 conditions:

Initial:

The Unit is at 6% power during a startup.

A problem required that N-36 be declared INOPERABLE.

Subsequent:

Due to erratic operation, N-35 "LEVEL TRIP" switch is placed in "BYPASS".

What is/are the MINIMUM required action(s), per Technical Specification 3.3.1, (Reactor Trip System Instrumentation)?

A.

Reduce thermal power to < P-6.

B.

Increase thermal power to > P-10.

C. Open both Reactor Trip Breakers IMMEDIATELY.

D. Suspend positive reactivity additions IMMEDIATELY, AND then reduce thermal power to <

P-6.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 24 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 24 In the event BOTH EMF-53A and EMF-53B become inoperable during an accident, which ONE of the following describes an alternate method used to estimate containment radiation levels?

A.

Use the indication on EMF-60 Annulus Radiation Monitor.

B.

Use the indication on EMF-71, 72, 73, 74 N16 Steam Line Monitors.

C. Have RP monitor the contact dose rate at center of outside airlock door.

D. Have an individual begin monitoring EMF-33, Condenser Air Ejector Monitor.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 25 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 25 During an event involving a fire in the plant, 1SLXG has become de-energized. A Reactor Operator is dispatched to start the Standby Shutdown Facility (SSF) Diesel Generator in accordance with AP/017 (Loss of Control Room) Case II (Loss of Plant Control Due to Fire or Security Event), Enclosure 10 (SSF D/G Startup).

At the SSF control panel the operator places the "SSF D/G MODE" switch to "EMERG" and then cranks the engine for 30 seconds. The engine does NOT start.

(1) In accordance with AP/017, Enclosure 10 what alternate method is prescribed for starting the engine?

(2) If the alternate method is successful (diesel engine starts), what are the effects on the SSF D/G?

A.

(1) Engage the fuel oil solenoid manual override, wait one to two minutes, then make another start attempt.

(2) ALL automatic trips and manual trips are disabled.

B.

(1) Engage the fuel oil solenoid manual override, wait one to two minutes, then make another start attempt.

(2) ONLY the high jacket water temperature and low lube oil pressure trips are disabled.

C. (1) Wait two minutes ONLY, and attempt another start by cranking the engine for up to 45 seconds.

(2) ONLY the engine overspeed and generator differential trips are disabled.

D. (1) Wait two minutes ONLY, and attempt another start by cranking engine for up to 45 seconds.

(2) ONLY the high jacket water temperature and low lube oil pressure trips are disabled.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 26 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 26 Unit 1 has tripped from 100% power. The operators transitioned from E-0, (Reactor Trip or Safety Injection) to ES-0.1, (Reactor Trip Response). There are indications of failed fuel based on the results of post-trip activity samples. AP/18, (High Activity in Reactor Coolant) is being implemented.

Which ONE of the following describes the correct actions to take with the NV system, including the reason for the action?

A.

Letdown is diverted to the Recycle Holdup Tank to limit radiation levels in the charging pump area.

B.

Charging and Letdown flows are reduced to limit radiation levels in the Auxiliary Building.

C. The cation bed is placed in service at greater than 80 gpm flow in order to reduce the amount of fission products in the reactor coolant system.

D. Ensure 1NV-153A is placed in "DEMIN" position and ensure one mixed bed demineralizer is aligned for purification of the reactor coolant.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 27 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 27 Given the following Unit conditions:

A transfer of control to the Standby Shutdown Facility (SSF) has been completed.

Natural circulation is being verified in accordance with OP/0/B/6100/013 (Standby Shutdown Facility Operations).

In-core thermocouple readings are:

582°F 610°F 588°F 600°F 585°F (1)

In accordance with OP/0/B/6100/013, what NC system pressure indication is used for determining the status of natural circulation?

(2)

IF that pressure indication is 1700 psig, and for the given conditions, does natural circulation currently exist?

Reference Provided A.

(1)

Pressurizer pressure (2)

Yes B.

(1)

Pressurizer pressure (2)

No C.

(1)

NC Loop B WR pressure (2)

Yes D.

(1)

NC Loop B WR pressure (2)

No

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 28 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 28 Regarding the cooling of the NC Pump motor and seals:

(1) For normal conditions, ____(1)____ cools the air flow through the motor.

(2) For Phase B actuation, seal cooling will be provided by the __________(2)___________.

Which ONE of the following completes the statements above?

A.

(1) RN (2) normal seal injection B.

(1) RN (2) thermal barrier heat exchanger C. (1) YV (2) normal seal injection D. (1) YV (2) thermal barrier heat exchanger

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 29 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 29 The effect of a failure of the #2 seal on 1A NCP is that the Standpipe _____(1)____ level alarm 1AD-7, A/1, (NCP A #2 Seal S-Pipe Hi/Lo Lvl), is received, and the NCP #1 Seal Leakoff

____(2)____ alarm is also received.

A.

(1) HIGH (2) HIGH B.

(1) HIGH (2) LOW C. (1) LOW (2) HIGH D. (1) LOW (2) LOW

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 30 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 30 Given the following Unit 1 conditions:

A unit shutdown for refueling is in progress, in accordance with OP/1/A/6100/002,.2, Unit Shutdown From Mode 3 To Mode 5.

1NV-148 (Letdown Pressure Control) controller is in AUTO.

(1)

As the cooldown continues and NC pressure decreases, the operator will need to

_____(1)_____ the control setpoint of 1NV-148 (Letdown Pressure Control).

(2)

One reason for the above operation is to __________(2)__________.

Which ONE of the following completes the above statement?

A.

(1) RAISE (2) maintain adequate NCP seal injection by maximizing charging flow B.

(1) RAISE (2) reduce the degasification time by maximizing letdown flow C. (1) LOWER (2) maintain adequate NCP seal injection by maximizing charging flow D. (1) LOWER (2) reduce the degasification time by maximizing letdown flow

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 31 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 31 Given the following conditions:

Pressurizer Pressure Master Controller is initially in MANUAL.

A failure of the Pressurizer Pressure Master Controller occurs.

All Pressurizer heaters were energized.

NC Pressure reached 2310 psig prior to termination of the event.

Which ONE of the following describes the effect on the PZR Surge Line temperature and charging flow due to this failure?

PZR Surge Line Temperature Charging Flow A.

INCREASED DECREASED B.

DECREASED DECREASED C.

INCREASED INCREASED D.

DECREASED INCREASED

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 32 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 32 Given the following Unit 1 conditions:

Both ND pumps are operating in RHR mode.

Cold Leg temperatures are:

Loop 1A:

215.4°F Loop 1B:

214.1°F Loop 1C:

211.8°F Loop 1D:

209.4°F 1ND-3 (1A ND Pump Suction From NC Loop B Header Relief) lift setpoint is WITHIN the required range.

1ND-38 (1B ND Pump Suction From NC Loop C Header Relief) lift setpoint is OUTSIDE of the required range.

One PORV (1NC-32B) is INOPERABLE.

Considering only the above conditions, is entry into LCO 3.4.12, (Low Temperature Overpressure) required, and why or why not?

A.

YES, because only ONE PORV is operable.

B.

NO, because the LCO does not apply for the given Unit conditions.

C.

NO, because Unit conditions satisfy the requirements of the specification.

D.

YES, because only ONE ND suction relief valve lift setpoint is within the required range.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 33 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 33 Given the following Unit 1 conditions:

The Unit is performing a cool down and depressurization for a refueling outage.

Both trains of PZR LO PRESS S/I and MAIN STEAM ISOL have been BLOCKED in accordance with OP/1/A/6100/002 (Controlling Procedure For Unit Shutdown).

A minor plant transient has caused NC pressure to INCREASE from 1830 psig to 1895 psig.

The crew has stabilized pressure and are preparing to re-initiate the cool down.

Which ONE of the following describes the status of the PZR LOW PRESS S/I and MAIN STEAM ISOL signals?

A.

Both signals are now ACTIVE.

B.

PZR LO PRESS S/I is still BLOCKED; MAIN STEAM ISOL is now ACTIVE.

C.

PZR LO PRESS S/I is now ACTIVE; MAIN STEAM ISOL is still BLOCKED.

D.

Both signals are still BLOCKED.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 34 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 34 In describing automatic operation of valves associated with the Pressurizer Relief Tank (PRT):

____________(1)___________ receives a CLOSE signal on a _______(2)_______ actuation.

Which ONE of the following completes the above statement?

A.

(1) 1NC-53B (N2 to PRT Cont Isol)

(2) Phase A B.

(1) 1NC-54A (N2 to PRT Cont Isol)

(2) Phase B C. (1) 1NC-56B (RMW Pump Disch to PRT Cont Isol)

(2) Phase B D. (1) 1NC-58A (PRT Spray Supply Isol)

(2) Phase A

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 35 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 35 Given the following plant conditions:

Unit 1 at 100% power.

PT/1/A/4200/023B, (NC PORV and Air Supply Stroke Test) is in progress.

1NC-36B (PZR PORV) stroke is performed and 1NC-35B (PZR Power Relief Isolation) is reopened.

1NC-36B (PZR PORV) OPENS and CANNOT be closed.

1NC-35B CANNOT be closed.

The Pressurizer Relief Tank (PRT) rupture disc will blow when PRT pressure FIRST reaches

______(1)______, at which point the Pressurizer PORV tailpipe temperature will

______(2)______.

Which ONE of the following completes the above statement?

A.

(1) 85 psig (2) remain the same B.

(1) 85 psig (2) decrease C. (1) 100 psig (2) remain the same D. (1) 100 psig (2) decrease

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 36 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 36 Given the following Unit 1 conditions:

The Standby Shutdown Facility (SSF) has been manned due to a fire in the cable spreading room.

During the course of SSF operations a reactor head vent was stuck in the open position for a short period of time and then reclosed.

You have been directed to increase NC pressure using Pressurizer heaters.

(1)

Why is pressure recovery slower from the SSF than from the Control Room?

(2)

What is the power supply for those heaters?

A.

(1)

Only a portion of the D heaters are available from the SSF.

(2)

SMXG B.

(1)

Only a portion of the D heaters are available from the SSF.

(2) 1EMXS C.

(1)

Only A and B heaters are available from the SSF.

(2) 1EMXS D.

(1)

Only A and B heaters are available from the SSF.

(2)

SMXG

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 37 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 37 Given the following Unit 1 conditions:

Reactor startup is in progress.

The permissive P-6 light on 1SI-18 has just LIT.

Reactor power is increasing.

In accordance with PT/0/A/4150/019, (1/M Approach to Criticality), the operator will:

(1) manually block the _________(1)_________ high flux reactor trip.

(2)

At this point, the reactor trip setpoint for high flux is _____(2)______.

A.

(1) Intermediate Range (2) 10%

B.

(1) Intermediate Range (2) 25%

C. (1) Source Range (2) 10%

D. (1) Source Range (2) 25%

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 38 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 38 Given the following Unit 1 conditions:

Initial:

Unit 1 was performing a heatup following a refueling outage.

NC System temperature was 400°F.

NC System pressure was 1600 psig.

A and B shutdown banks were withdrawn.

Containment Pressure Channel II failed high.

Current:

1ERPD has lost power.

Containment pressure channels read:

Channel I:

0 psig Channel II:

+5 psig Channel III:

0 psig Channel IV: -5 psig Which ONE of the following describes the effect on the Engineered Safeguards Features (ESF) system and the FIRST appropriate procedure entry?

A.

ONLY Train A ESF equipment starts.

AP/1/A/5500/005, Reactor Trip or Inadvertent S/I Below P-11.

B.

ONLY Train A ESF equipment starts.

EP/1/A/5000/E-0, Reactor Trip or Safety Injection.

C. BOTH Train A AND B ESF equipment starts.

AP/1/A/5500/005, Reactor Trip or Inadvertent S/I Below P-11.

D. BOTH Train A AND B ESF equipment starts.

EP/1/A/5000/E-0, Reactor Trip or Safety Injection.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 39 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 39 Given the following Unit 1 conditions:

Initial:

The Unit is at 100% power.

Lower Containment Ventilation Units (LCVUs) 1A, 1B, 1D are operating in LOW speed with MAX cooling.

Upper Containment Ventilation Unit (UCVU) 1A is operating in NORM.

Subsequent:

Containment humidity begins increasing.

Containment temperature and pressure are slowly increasing.

Containment radiation levels are normal.

In accordance with AP/1/A/5500/028, (Secondary Steam Leak), the required operation for LCVU 1C is to start it in _____(1)_____ speed, and place it in _____(2)_____ cooling.

A.

LOW MAX B.

LOW NORM C. HIGH MAX D. HIGH NORM

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 40 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 40 Given the following Unit 1 conditions:

Initial:

The Unit is at 100% power.

The following Lower Containment Ventilation Units are in service at low speed:

1A LCVU 1B LCVU 1C LCVU Subsequent:

1C LCVU TRIPS for an unknown reason.

In response, the operator manually starts 1D LCVU.

1D LCVU starts and immediately TRIPS on overcurrent.

Lower Containment Average Temperature is 118°F and is steadily increasing.

In accordance with OP/1/A/6450/001 (Containment Ventilation Systems), Enclosure 4.11 (LCVU Additional Cooling):

(1) How many LCVUs are required to be placed in HIGH speed?

(2) What is the reason for the associated maximum time restriction on operating with this configuration?

A.

(1) ONE (2) Potential fan bearing problems.

B.

(1) TWO (2) Potential fan bearing problems.

C. (1) ONE (2) Elevated Containment Air Temperature requirements.

D. (1) TWO (2) Elevated Containment Air Temperature requirements.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 41 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 41 Given the following Unit 1 conditions:

The Unit was initially at 100% power.

Subsequently, a Loss of Coolant Accident occurred.

Currently:

EP/1/A/5000/ES-1.3, Transfer to Cold Leg Recirculation is being implemented.

Containment pressure is 4.6 psig and slowly increasing.

Containment sump annunciators are as follows:

1AD-20, B/2 (CONT. SUMP LEVEL > 2.5 FT) - LIT 1AD-21, B/2 (CONT. SUMP LEVEL > 2.5 FT) - DARK 1AD-20, B/3 (CONT. SUMP LEVEL > 3.3 FT) - DARK 1AD-21, B/3 (CONT. SUMP LEVEL > 3.3 FT) - DARK At this point, which ONE of the following describes whether the crew can align Containment Spray (NS) for recirculation, including the reason?

A.

NO, because containment sump level is too LOW.

B.

NO, because only ONE channel of containment sump level > 2.5 ft has alarmed.

C.

YES, because at least ONE channel of containment sump level > 2.5 ft. has alarmed.

D.

YES, because containment pressure is greater than 3.0 psig.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 42 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 42 Which ONE of the following describes an interlock that is designed to prevent cross contamination of the FWST from the Containment Sump?

A.

In order to OPEN:

NI-115A (NI Pump A Miniflow) or NI-144A (NI Pump B Miniflow)

These valves must be CLOSED:

NI-136B (ND Supply to NI Pump B)

ND-28A (ND Supply to NV and NI Pump A)

B.

In order to OPEN:

NS-18A (NS Pump A Sump Suction)

These valves must be as follows:

NS-20A (NS Pump A FWST Suction Block) must be CLOSED.

NI-185A (Containment Sump Isolation) must be OPEN.

C. In order to OPEN:

FW-27A (ND Pump A Suction from FWST)

These valves must be CLOSED:

NS-18A (NS Pump A Suction from Containment Sump)

ND-28A (ND Supply to NV and NI Pump A)

NI-185A (Containment Sump Isolation)

ND-43A (ND Pump A to Containment Spray Header)

D. In order to OPEN:

NS-43A (ND Pump A to Containment Spray Header)

At least ONE of these valves must be CLOSED:

ND-1B (ND Pump Suction from NC)

ND-2A (ND Pump Suction from NC)

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 43 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 43 Unit 1 tripped from 100% power with the following subsequent conditions:

B Reactor trip breaker remains CLOSED.

EP/1/A/5000/ES-0.1 (Reactor Trip Response) in progress.

  • (NC Temperature Control) is in effect.

(1) Which steam dump controller is in control initially?

(2) In accordance with ES-0.1, Enclosure 2, how will temperature control be accomplished to stabilize Tavg at 557°F?

A. (1) load rejection controller (2) Use S/G PORVs to stabilize Tavg.

B. (1) load rejection controller (2) Use steam dumps to stabilize Tavg.

C. (1) The plant trip controller (2) Use steam dumps to stabilize Tavg.

D. (1) The plant trip controller (2) Use S/G PORVs to stabilize Tavg.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 44 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 44 In accordance with OP/1/A/6250/001, Condensate and Feedwater System, the crew is starting a Feedwater Pump. The operator is at Enclosure 4.3, (Feedwater Pump Startup), Step 2.2 which contains direction on oil warming.

(1)

Prior to exceeding 1500 rpm on the Feedwater Pump, the operator must ensure that CFPT lube oil temperature is at least ________.

(2)

Based on the Limits and Precautions of OP/1/A/6250/001, the reason for this requirement is to _________________________________________.

A.

(1) 110ºF (2) prevent bearing damage AND ensure proper hydraulic control operation B.

(1) 110ºF (2) prevent bearing damage ONLY C. (1) 60ºF (2) prevent bearing damage AND ensure proper hydraulic control operation D. (1) 60ºF (2) prevent bearing damage ONLY

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 45 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 45 (1) Which component, if INOPERABLE, requires entry into Tech. Spec. 3.7.3 (Main Feedwater Isolation Valves (MFIVs), Main Feedwater Control Valves (MFCVs), Associated Bypass Valves and Tempering Valves)?

(2) Assuming this valve is OPEN, what are the modes of applicability for this LCO?

A.

(1) S/G CA Nozzle Tempering Control Valve (1CF-100)

(2) Mode 1, Mode 2, and Mode 3 ONLY B.

(1) S/G CA Nozzle Tempering Isolation Valve (1CA-185)

(2) Mode 1, Mode 2, Mode 3, and Mode 4 C. (1) S/G CF Bypass to CA Nozzle Valves (1CA-149)

(2) Mode 1, Mode 2, and Mode 3 ONLY D. (1) S/G CF Bypass to CA Nozzle Valves (1CA-149)

(2) Mode 1, Mode 2, Mode 3, and Mode 4

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 46 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 46 Given the following Unit 1 conditions:

A reactor trip from 100% power has occurred.

Bus 1ETA has locked out.

The CAPT Pump started and immediately tripped on overspeed.

Which S/Gs are currently being fed?

A.

A and B S/Gs ONLY B.

C and D S/Gs ONLY C. A and C S/Gs ONLY D. B and D S/Gs ONLY

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 47 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 47 Assume Unit conditions at 100% power.

How is the concern for potential feed line voiding and water hammer in the discharge piping of the CA pumps addressed?

If a ________(1)_________ condition exists, an OAC alarm annunciates.

To mitigate this condition, the operators will ______________(2)_____________________.

A.

(1) high pressure (2) run the CA pump to flush and reseat the CA pump discharge check valve B.

(1) high temperature (2) run the CA pump to flush and reseat the CA pump discharge check valve C. (1) high temperature (2) operate 1CF-105 (S/G Tempering Flow Supply Throttle) to increase tempering flow D. (1) high pressure (2) operate 1CF-105 (S/G Tempering Flow Supply Throttle) to increase tempering flow

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 48 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 48 Given the following Unit 1 conditions:

The Unit is at 100% power.

Annunciator 1AD-11 C/2 Transformer 1A Forced Cooling Reduction is received.

The annunciator has been lit for 5 minutes.

Generator PCB 1A is currently closed.

The NLO dispatched to respond to this alarm has not yet reported back.

Based on the above conditions:

(1) How many cooling fan banks have been lost?

(2) What is the NEXT automatic action to occur?

(Assume NO operator action.)

A.

(1)

ONE (2) 1A Generator PCB trip B.

(1)

ONE (2)

Unit runback C. (1)

TWO (2)

Unit runback D. (1)

TWO (2)

Zone A Lockout

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 49 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 49 Which ONE of the following describes which of the DC breakers (labeled 1, 2, 3, 4 in the drawing above) will cause an alarm to be received in the Control Room when the breakers OPEN?

A.

Any one of the four breakers.

B.

Breakers 1 and 3 ONLY.

C. Breakers 2 and 3 ONLY.

D. Breakers 2 and 4 ONLY.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 50 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 50 Given the following Unit 1 conditions:

The Unit is initially at 100% power.

A complete loss of offsite power occurs.

Neither of the DGs will start.

(1)

Battery discharge rates will cause the above indicators (1CDA, 1EDA) to decrease at a steady rate over a period of approximately _____(1)_____.

(2)

At the end of that time period, the above indicators will decrease _____(2)______.

rapidly.

In accordance with the appropriate abnormal procedure, which ONE of the following completes the statements above?

(Assume no operator action.)

A.

(1) Two hours (2) more B.

(1) Two hours (2) less C. (1) Eight hours (2) more D. (1) Eight hours (2) less

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 51 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 51 Given the following Unit 1 conditions:

A malfunction of the feeder breaker from 1ATC to 1ETA occurs and causes 1ETA to de-energize.

Jacket Water temperature immediately begins increasing.

5 minutes after the D/G started, the High Jacket Water Temperature outlet trip setpoint is exceeded.

Which ONE of the following describes the status of the protective trip for the D/G on High Jacket Water Temperature?

A. The D/G can ONLY be tripped manually throughout the event.

B. The D/G automatically trips as soon as the trip setpoint is reached.

C. The D/G automatically trips when the ENABLE NON-EMERG TRIP pushbutton ONLY is depressed.

D. The D/G automatically trips when BOTH the Sequencer is reset AND the ENABLE NON-EMERG TRIP pushbutton is depressed.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 52 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 52 Concerning the operation of 1EMF-46A (Component Cooling Water):

(1) When a Trip 2 alarm is received, 1KC-122 (KC Surge Tank Vent) _____________

automatically close.

(2) When the associated KC train pumps are NOT running, the EMF loss of flow alarm

________________ blocked from being received in the control room.

A.

(1) does (2) is B.

(1) does (2) is NOT C. (1) does NOT (2) is D. (1) does NOT (2) is NOT

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 53 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 53 Given the following plant conditions:

Initially:

Both Units are at 100% power.

A flooding event begins to occur.

The source of flooding is from a rupture on the main RL supply header to the KR heat exchangers in Unit 1 Service Building.

Currently:

The operators have isolated RL to the KR heat exchangers to attempt to stop the flooding.

In accordance with AP/0/A/5500/030, (Plant Flooding):

To mitigate these conditions, the operators are required to ___________(1)_____________ due to the effect of the RL to KR isolation on cooling for ___________(2)_______________.

A.

(1) Trip BOTH reactors.

(2) CM/CF pumps B.

(1) Trip BOTH reactors.

(2) C-Heater Drain Tank pumps C. (1) Perform a Rapid Downpower to less than 69%.

(2) CM/CF pumps D. (1) Perform a Rapid Downpower to less than 69%.

(2) C-Heater Drain Tank pumps

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 54 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 54 Given the following Unit 1 conditions:

The Unit is shutdown for a refueling outage.

WR Loop 1A NC Level is 83.4%.

WR Loop 1C NC Level is 83.4%.

1A Train of ND is in service.

ND suction temperature on the OAC is 103.2ºF.

1A ND Hx outlet temperature is 90.1ºF.

1A KC Hx outlet temperature is 87.0ºF.

Subsequently:

A short in the motor operator for 1RN-287A (KC 1A Hx Inlet Isol) results in the valve going full CLOSED.

1RN-287A cannot be reopened.

In response to the above failure, (1) 1ND-26 (ND Hx 1A Outlet Ctrl) will require manual operation in the ____(1)____ direction.

(2) As a result of the above operation of 1ND-26, 1ND-27 (ND Hx 1A Bypass Ctrl) will

__________(2)___________.

A.

(1) CLOSED (2) require manual operation in the CLOSED direction.

B.

(1) CLOSED (2) automatically modulate in the OPEN direction.

C. (1) OPEN (2) require manual operation in the CLOSED direction.

D. (1) OPEN (2) automatically modulate in the CLOSED direction

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 55 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 55 With Unit 1 at 100% power, which ONE of the following states the MAXIMUM possible number of Personnel Airlock seals per airlock that can FAIL, and still maintain containment integrity?

A.

ONE inner AND ONE outer door seal.

B.

ONE of the inner OR ONE of the outer door seals.

C.

BOTH of the outer AND ONE inner door seal.

D.

BOTH of the inner OR BOTH of the outer door seals.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 56 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 56 Given the following Unit 2 conditions:

The Unit is in Mode 6 with fuel loading in progress.

A spike occurs on "A" Train BDMS (Boron Dilution Mitigation System).

2AD-2, E/2 Train A Shutdown Margin Alarm is LIT.

The VCT OUTLET VALVE INTERLOCK switch is in "NORMAL."

(1) What is the FINAL alignment of the following components?

2NV-252A (NV Pumps Suct From FWST) 2NV-253B (NV Pumps Suct From FWST)

(2) Which of the following pumps receive a trip signal?

2A Reactor Makeup Water Pump 2B Reactor Makeup Water Pump A.

1)

Only 2NV-252A OPENS

2)

Only 2A B.

1)

Both 2NV-252A and 2NV-253B OPEN

2)

Only 2A C. 1)

Only 2NV-252A OPENS

2)

Both 2A and 2B D. 1)

Both 2NV-252A and 2NV-253B OPEN

2)

Both 2A and 2B

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 57 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 57 Given the following Unit 1 conditions:

The Unit is at 100% power.

The final feedwater temperature input to the thermal power best estimate (TPBE) was incorrectly calibrated to 7°F less than actual feedwater temperature.

(1)

Indicated TPBE power will be ______________ than actual thermal power.

(2)

By using the calculated value of TPBE as described above, calibration of the NIs will result in setpoints that are ______________ conservative.

Which ONE of the following completes the above statements?

A. (1) LOWER (2) LESS B. (1) HIGHER (2) LESS C. (1) HIGHER (2) MORE D. (1) LOWER (2) MORE

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 58 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 58 Which ONE of the following identifies why an Isolation Amplifier is used in the Loop Tavg circuits?

A.

To prevent a failed RTD from resulting in a loss of Reactor Control.

B.

To prevent a failed RTD from producing a Reactor Trip signal.

C.

To ensure that a fault in the control circuit of the instrument does not affect its associated protection circuits.

D.

To ensure that a fault in the protection circuit of the instrument does not affect its associated control circuits.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 59 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 59 Given the following Unit 1 conditions:

A LOCA occurred 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> ago.

The 1A H2 Recombiner was placed in service per OP/1/A/6450/010 (Containment Hydrogen Control Systems).

When the Recombiner was first placed in service containment parameters were:

o Pressure:

4.8 psig o

H2 concentration:

3.2%

Current containment conditions (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> later):

Pressure:

2.7 psig H2 concentration:

3.6%

(1)

Based on the conditions above when the recombiner was INITIALLY placed in service, the Power Setting was ____(1)____.

(2)

Based on the current containment conditions, the Power Setting will NOW be adjusted to

_____(2)_____.

Reference Provided A.

(1) 60.0 KW (2) 57.6 KW B.

(1) 60.0 KW (2) 61.6 KW C. (1) 54.6 KW (2) 57.6 KW D. (1) 54.6 KW (2) 61.6 KW

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 60 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 60 Given the following Unit 1 conditions:

Initial:

For a refueling outage, the Unit was shutdown on September 2.

Current:

The Unit is at 100% power.

1A KF Pump is in service.

Due to an emergent issue, 1B KF Pump has been tagged out and is currently disassembled.

The date is September 29.

Spent Fuel Pool level is 39.9 ft.

Spent Fuel Pool temperature is 113.6°F.

Subsequent:

1A KF Pump trips for an unknown reason.

The crew enters AP/1/A/5500/041, (Loss of Spent Fuel Pool Cooling or Level).

(1) In approximately _____(1)_____ hours, the indication on 1EMF-15 (Spent Fuel Bldg Refuel Brdg) will FIRST begin to rise significantly.

(2) To restore Spent Fuel Pool cooling and exit the AP, one KF pump must be restored and the Spent Fuel Pool temperature must be reduced to NO GREATER THAN _____(2)_____.

In accordance with AP/041, which ONE of the following completes the above statements?

Reference Provided A.

(1) 17 (2) 125°F B.

(1) 37 (2) 125°F C. (1) 17 (2) 140°F D. (1) 37 (2) 140°F

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 61 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 61 With Unit 1 in Mode 6, a fuel handling accident involving fuel damage occurs and results in an alarm condition on 1EMF-17, Reactor Building Refueling Bridge.

(1)

Which EMF is used to provide additional radiation monitoring for the above conditions, in accordance with AP/025, (Damaged Spent Fuel)?

(2)

If the radiation monitor reaches its Trip 2 setpoint, the Containment Evacuation Alarm A.

(1) 1EMF-53A/B, Containment Train A/B (2) will automatically actuate B.

(1) 1EMF-53A/B, Containment Train A/B (2) must be manually actuated C. (1) 1EMF-38, Containment Particulate Monitor (2) will automatically actuate D. (1) 1EMF-38, Containment Particulate Monitor (2) must be manually actuated

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 62 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 62 Given the following conditions:

A planned release of the contents of Waste Monitor Tank (WMT) B was initiated per OP/0/B/6500/113, (Operations Liquid Waste Release).

(1) IF 1RAD-1, F/4, EMF-49 LIQUID WASTE DISCH LOSS OF FLOW, alarms and can NOT be cleared, the release is terminated ________________________.

(2) IF 1AD-12, F/3, RL DISCHARGE LOW FLOW alarms, the release is terminated Considering each of the above valid alarms separately, which ONE of the following completes the above statements?

A.

(1) automatically (2) automatically B.

(1) automatically (2) manually C. (1) manually (2) automatically D. (1) manually (2) manually

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 63 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 63 Given the following plant conditions:

A failure of an isolation valve in the WG system has resulted in an unintentional release of radioactive gas into the Auxiliary Building.

The VA system has automatically aligned to the following configuration:

VA System Component Status Unit 1 and 2 Filtered Exhaust Fans ON Unit 1 Supply Fans OFF Unit 2 Supply Fans ON Unit 1 Unfiltered Exhaust Fans OFF Unit 2 Unfiltered Exhaust Fans ON The following Area Radiation Monitor annunciator is in alarm:

1RAD-3, B/6, (1EMF6 543 MM, 61-62 WG/Resin Area)

Which ONE of the following describes the MINIMUM number of radiation monitors that, if in the Trip 2 condition, will account for the above conditions?

A.

1EMF-6 (Waste Gas and Spent Resin Area) 1EMF-35 (Unit Vent Particulate Monitor)

B.

1EMF-6 (Waste Gas and Spent Resin Area) 0EMF-41 (Auxiliary Building Ventilation Monitor)

C. 1EMF-6 (Waste Gas and Spent Resin Area) 1EMF-35 (Unit Vent Particulate Monitor) 0EMF-41 (Auxiliary Building Ventilation Monitor)

D. 0EMF-41 (Auxiliary Building Ventilation Monitor) 1EMF-35 (Unit Vent Particulate Monitor) 0EMF-50L (Waste Gas Discharge - Low Range)

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 64 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 64 If 1B and 2B Nuclear Service Water System (RN) pumps are running (with normal suction and discharge alignment) and a blackout occurs on 2ETA, which ONE of the following will occur?

A.

BOTH Train A RN pumps start.

B.

ONLY the Unit 2 RN Pump A starts.

C. ONLY the Unit 1 RN Pump A starts.

D. NEITHER Train A RN Pumps start.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 65 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 65 Given the following Unit 1 conditions:

Initial:

The Unit is at 100% power.

VI Compressors D and E are running and loaded.

VS Compressor A is in BASE mode and running.

VS Compressor B is in STANDBY mode.

VS is being supplied from VI.

Subsequent:

1VI-500 (VI Supply to VS) is closed.

VI pressure is no longer decreasing.

VS Compressor A TRIPS on high discharge air temperature.

0VIP5260 on 1MC13 indicates that VS (Station Air) header pressure is 72 psig and continuing to DECREASE.

VS Compressor B is NOT running.

(1) What provides guidance for the required action?

(2) What is the required action?

A.

(1) OAC Alarm Response (2) Dispatch an operator to manually start VS Compressor B.

B.

(1) OAC Alarm Response (2) Manually start VI Compressor F.

C. (1) AP/022, Loss of Instrument Air (2) Manually start VI Compressor F.

D. (1) AP/022, Loss of Instrument Air (2) Dispatch an operator to manually start VS Compressor B.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 66 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 66 Curve #1 Curve #2 The above curves are from:

EP/1/A/5000/FR-P.1, Response to Imminent Pressurized Thermal Shock Condition EP/1/A/5000/FR-P.2, Response to Anticipated Pressurized Thermal Shock Condition (1)

The curve for FR-P.1 is ________(1)________.

(2) When the crew begins a controlled cooldown the maximum allowed cooldown rate will be

_____(2)______ restrictive for FR-P.1 than for FR-P.2.

A.

(1) Curve #1 (2) more B.

(1) Curve #1 (2) less C. (1) Curve #2 (2) more D. (1) Curve #2 (2) less

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 67 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 67 Note the table below from SLC 16.5-3, Chemistry (excerpt).

PARAMETER STEADY STATE LIMIT TRANSIENT LIMIT Dissolved Oxygen

< 0.10 ppm

< 1.00 ppm Chloride

< 0.15 ppm

< 1.50 ppm Fluoride

< 0.15 ppm

< 1.50 ppm (1) In accordance with SLC 16.5-3, Chemistry, Fluoride is a ________(1)_________ chemistry parameter.

(2) In accordance with the applicable abnormal operating procedure, if dissolved oxygen were at a value in Action Level 3, a shutdown to Mode 3 would be required in _____(2)____

hours.

Which ONE of the following completes the statements above?

A.

(1) Primary (2) 3 B.

(1) Primary (2) 24 C. (1) Secondary (2) 3 D. (1) Secondary (2) 24

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 68 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 68 During a Unit 1 startup, the OATC is preparing to perform a dilution.

The following individuals are present in the Unit 1 control room:

An individual enrolled in Hot License Prep class on shift for OJT.

An SRO dedicated to the start-up.

Shift Technical Advisor (SRO licensed)

Control Room Supervisor In accordance with SOMP 01-02, (Reactivity Management):

Of the individuals currently in the control room, who is authorized to perform the Peer Check for the reactivity manipulation?

A.

ONLY the HLP student or the Control Room Supervisor.

B.

ONLY the HLP student or the SRO dedicated to the start-up.

C. ONLY the SRO dedicated to the start-up or Shift Technical Advisor.

D. ONLY the Control Room Supervisor (CRS) or Shift Technical Advisor.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 69 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 69 During an outage, a planned maintenance activity will result in a YELLOW Defense in Depth (DID) sheet configuration.

In accordance with NSD 403 (Shutdown Risk Management),

1) Defense in Depth (DID) sheets are first initiated once _____(1)_____is reached on a shutdown.
2) A RISK MANAGEMENT PLAN is _____(2)_____ for a YELLOW risk condition.

A.

(1) Mode 3 (2) optional B.

(1) Mode 3 (2) required C. (1) Mode 4 (2) optional D. (1) Mode 4 (2) required

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 70 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 70 Given the following Unit 1 conditions:

Plant conditions have been stable for the past 15 minutes.

Loop 1A Tavg is 572.0 °F.

Loop 1B Tavg is 570.0 °F.

Loop 1C Tavg is 570.0 °F.

Loop 1D Tavg is 568.0 °F.

Tref is 568.0°F.

The CRD Bank Select Switch is in MANUAL.

If the CRD Bank Select Switch is placed in AUTO, the control rods will initially...

A.

NOT step.

B.

Step IN at 8 steps/minute.

C. Step IN at 40 steps/minute.

D. Step IN at 54 steps/minute.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 71 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 71 Following a planned waste gas release, in accordance with OP/0/A/6500/080, (EMF RP86A Output Modules)

OP/0/A/6500/019, (Operations Waste Gas Release)

What guidance is used to calculate and enter the new setpoints for EMF 50 (Waste Gas Disch Hi Rad)?

(1) Trip 2 is set to ____(1)____ the EMF reading after the purge.

(2) Trip 1 is set for ___(2)___ of the Trip 2 setpoint.

A.

(1) 2 times (2) 70%

B.

(1) 2 times (2) 80%

C. (1) 3 times (2) 70%

D. (1) 3 times (2) 80%

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 72 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 72 Given the following Unit 1 conditions:

The unit has experienced several fuel pin failures.

You have been directed to tag out the 1B NI pump.

The 1B NI pump room general area is 400 mREM/hr.

To reach the 1B NI pump room you must transit through a 6 REM/hr high radiation area for 2 minutes and return via the same route.

Your current accumulated annual dose is 990 mREM.

An RWP has been written for this job which has your Electronic Dosimeter (ED) alarm set for your EXCLUDE exposure limit.

Based on the conditions above, what is your MAXIMUM allowable stay-time in the 1B NI pump room for hanging the tag out to prevent your ED from alarming before you exit the RCA?

A.

30 minutes B.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> C.

1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> D.

2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 73 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 73 During conditions involving the implementation of Emergency Procedures, and in accordance with OMP 1-7, (Emergency/Abnormal Procedure Implementation Guidelines), control board manipulations may be performed by an SRO other than the ______(1)______, ONLY if authorized by the ______(2)______.

Which ONE of the following completes the above statement?

A.

(1) Unit Supervisor (2) Control Room Supervisor B.

(1) Unit Supervisor (2) Operations Shift Manager C. (1) Control Room Supervisor (2) Operations Shift Manager D. (1) Operations Shift Manager (2) Control Room Supervisor

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 74 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 74 With the reactor initially at 100% power, which ONE of the following would result in implementation of E-0, (Reactor Trip or Safety Injection)?

A.

One (1) NR level for SG 1A indicates 84%.

B.

Main turbine bearing #11 vibration increases to 8 mils.

C.

Main turbine lube oil cooler outlet temperature is at 140ºF and slowly increasing.

D.

Main condenser vacuum decreases to 21.0" Hg.

Catawba Nuclear Station 2012 NRC Initial License Written Exam REACTOR OPERATOR Page 75 of 75 Catawba 2012 NRC Initial License Written Exam - RO Question 75 During a Unit 1 event, the following conditions for the listed times exist:

1000 1030 1050 1110 Level in S/G (%)

1A 12 15 30 32 1B 13 16 31 33 1C 15 18 32 32 1D 6

10 30 30 Pressure in S/G (psig) 1A 1205 1150 1100 1085 1B 1210 1145 1105 1090 1C 1215 1100 1105 1090 1D 1170 1110 1108 1105 Containment Pressure (psig) 3.1 3.3 3.1 2.8 Considering only the given conditions, which ONE of the following is the earliest TIME at which the Critical Safety Function for "Heat Sink" is SAT?

A.

1000 B.

1030 C.

1050 D.

1110

REACTOR OPERATOR Catawba Nuclear Station HLP 2012 NRC Written Exam (Oct. 2012)

REFERENCE PACKAGE CONTENTS EXAM ID:

HLP12 NRC Exam RO Exam 1

OP/1/A/6750/010, (Distributed Control System (DCS) Operations:

Encl. 4.6.2 Encl. 4.6.3 Encl. 4.6.4 Encl. 4.6.7 2

OP/1/A/6450/010, (Containment Hydrogen Control Systems), Encl. 4.10 3

AP/1/A/5500/041, (Loss of Spent Fuel Cooling or Level), Enclosure 1 4

Unit ONE Revised Data Book, Figure 10, (Unit 1 Hydrogen Recombiners Post-LOCA Power Consumption) 5 Unit ONE Revised Data Book, Figure 57, (Reactor Coolant Saturation Curve, Wide Range)

HLP 2012 - NRC Written Exam - Answer Key (1-75 is RO Exam;76-100 is SRO only portion)

Status Status Status Status 1

D 26 D

51 D

76 A

2 D

27 D

52 C

77 A

3 D

28 C

53 A

78 D

4 A

29 B

54 D

79 C

5 B

30 D

55 C

80 B

6 B

31 A

56 D

81 A

7 B

32 C

57 C

82 B

8 A

33 D

58 C

83 C

9 C

34 A

59 B

84 B

10 B

35 D

60 B

85 C

11 B

36 A

61 C

86 D

12 A

37 D

62 C

87 A

13 D

38 A

63 A

88 D

14 A

39 A

64 A

89 B

15 D

40 B

65 A

90 B

16 B

41 A

66 C

91 C

17 D

42 A

67 A

92 D

18 D

43 B

68 B

93 C

19 A

44 A

69 C

94 B

20 D

45 C

70 B

95 B Question deleted (post exam comment) 21 D

46 B

71 C

96 C

22 D

47 B

72 B

97 C

23 D

48 B

73 C

98 A

24 C

49 D

74 D

99 A

25 A

50 A

75 C

100 D