MONTHYEARML1008200192010-03-24024 March 2010 Purdue University, Request for Additional Information, Renewal of Facility Operating License, Financial Qualifications (Tac No. ME1594) Project stage: RAI ML1016201842010-06-0404 June 2010 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal (Tac No. Me 1594), Responses to RAIs Dated 24 March 2010 Project stage: Response to RAI ML1014604292011-07-0606 July 2011 Purdue University - 30 Day Request for Additional Information Regarding the PUR-1 License Renewal Project stage: RAI ML1034001152011-07-0808 July 2011 Purdue University - 60 Day Request for Additional Information Regarding the PUR-1 License Renewal Project stage: RAI ML1034002502011-07-14014 July 2011 Purdue University - 90 Day Request for Additional Information Regarding the PUR-1 License Renewal Project stage: RAI ML1117906492011-08-11011 August 2011 Purdue University, Letter to Licensee, Notice of Acceptance for Docketing and Opportunity to Provide Written Comments And/Or Request a Hearing and Order Imposing Procedures for Access to SGI and SUNSI License Renewal (Tac ME1594) Project stage: Acceptance Review ML1123719362011-08-23023 August 2011 Purdue University - E-mail from J. Jenkins, Purdue to D. Hardesty NRC Project Manager Request for an Extension of Time to Respond to NRC Request for Additional Information Project stage: Request ML0933806932011-10-28028 October 2011 FRN: General Notice. Purdue University Notice of Acceptance for Docketing and Opportunity to Provide Written Comments And/Or Request a Hearing and Order Imposing Procedures for Access to SGI and SUNSI License Renewal (Tac No. ME1594) Project stage: Acceptance Review ML1133604702011-11-0404 November 2011 Purdue University - E-mail from J. Jenkins, Purdue to C. Montgomery, NRC Project Manager, Request for an Extension to Respond to NRC Request for Additional Information (30-Day) Dated July 6, 2011 (Tac No. ME1594) Project stage: Request ML11320A2872011-11-15015 November 2011 Response to Request for Additional Information Regarding the Purdue University Reactor License Renewal (TAC ME1594), Response to RAIs Dated 6 July 2011 (ML101460429) Project stage: Response to RAI ML1133604912011-12-28028 December 2011 Purdue University - Approval of Request for an Extension of Time to Respond to NRC Request for Additional Information (Tac No. ME1594) Project stage: RAI ML1200500042012-01-0404 January 2012 Purdue University - E-mail from J. Jenkins, Purdue to C. Montgomery, NRC Project Manager Licensee Requesting Extension to Respond to NRC Request for Additional Information Dated July 8, 2011 and July 14, 2011 (Tac No. ME1594) Project stage: Request ML12006A1932012-01-0404 January 2012 Purdue University - Request for Additional Information Regarding the License Renewal, Responses to RAIs Dated 6 July 2011 Project stage: Response to RAI ML12031A2232012-01-30030 January 2012 Purdue University - Responses to the Request for Additional Information Regarding the Purdue University Reactor License Renewal Dated July 6, 2011 Project stage: Request ML14234A1092012-01-31031 January 2012 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal (TAC No. Me 1594), Responses to Rais (ML103400115 and ML103400250) (Redacted Version) Project stage: Response to RAI ML1209005712012-03-26026 March 2012 Purdue University License Renewal -- Renewal for Additional Time to Respond to the 60 and 90 Day Requests for Additional Information (Rais) Until January 31, 2012 Project stage: Other ML1213606312012-05-11011 May 2012 Email - Purdue University License Renewal-Submission Schedule for Request for Additional Time to Respond to the 60- and 90-day Requests for Additional Information (RAIs)--Until January 31, 2012 Project stage: Request ML1210301972012-05-29029 May 2012 Purdue University - NRC Approval of Request for Additional Time to Respond to the 60- and 90-day Requests for Additional Information Until January 31, 2013 Project stage: RAI ML12156A3642012-06-0101 June 2012 Request for Additional Information Regarding the Purdue University Reactor License Renewal (TAC ME1594), Responses to RAIs (ML103400115 and ML103400250) Project stage: Response to RAI ML12170B0182012-06-15015 June 2012 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal (TAC No. ME1594), Responses to RAIs (ML103400115 and ML103400250) Project stage: Response to RAI ML1218500042012-06-29029 June 2012 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal, Responses to RAIs (ML103400115 and ML103400250) Project stage: Response to RAI ML12201A0702012-07-13013 July 2012 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal, Response to RAI Project stage: Response to RAI ML12226A4002012-08-11011 August 2012 Purdue University - Response to Request for Additional Information Regarding Purdue University Reactor License Renewal (TAC No. ME1594, Responses to RAIs (ML103400115 and ML103400250) Project stage: Response to RAI ML13101A0442013-04-10010 April 2013 Purdue University - Response to Request Request for Additional Information Regarding the Purdue University Reactor License Renewal Project stage: Request ML14115A2212014-08-29029 August 2014 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal Application Project stage: RAI ML15210A2852015-07-24024 July 2015 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal Application (TAC No. ME1594), Responses to Letter Dated August 29, 2014 (ML14115A221). Part 3 of 5 Project stage: Request ML15210A2872015-07-24024 July 2015 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal Application (TAC No. ME1594), Responses to Letter Dated August 29, 2014 (ML14115A221). Part 4 of 5 Project stage: Request ML15210A2882015-07-24024 July 2015 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal Application (TAC No. ME1594), Responses to Letter Dated August 29, 2014 (ML14115A221). Part 5 of 5 Project stage: Request ML15210A2832015-07-24024 July 2015 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal Application (TAC No. ME1594), Responses to Letter Dated August 29, 2014 (ML14115A221). Part 2 of 5 Project stage: Request ML15210A2802015-07-24024 July 2015 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal Application (TAC No. ME1594), Responses to Letter Dated August 29, 2014 (ML14115A221) Project stage: Request ML15210A2822015-07-24024 July 2015 Purdue University - Request for Additional Information Regarding the Purdue University Reactor License Renewal Application (TAC No. ME1594), Responses to Letter Dated August 29, 2014 (ML14115A221). Part 1 of 5 Project stage: Request ML15349B0432015-12-23023 December 2015 Purdue University Research Reactor - Request for Additional Information Physical Security Plan Review for License Renewal Project stage: RAI ML15328A3142016-01-19019 January 2016 Purdue University - Request for Additional Information Re Renewal of License No. R-87 Project stage: RAI ML16047A3822016-01-29029 January 2016 Purdue University - Response to NRC Request for Additional Information Regarding Physical Security Plan Review for License Renewal Project stage: Response to RAI ML16083A2192016-02-26026 February 2016 Purdue University - Re-Submittal Response to NRC Request for Additional Information Regarding Physical Security Plan Review for License Renewal Project stage: Response to RAI ML16102A1232016-03-31031 March 2016 Purdue Re-Submittal of Response to NRC Request for Additional Information Physical Security Plan Review for License Renewal Project stage: Response to RAI ML16102A1192016-03-31031 March 2016 Purdue Univ., Submittal of 2015 Annual Report for PUR-1 Project stage: Request ML16134A1432016-05-0909 May 2016 Purdue University - Second Re-Submittal of Response to NRC Request for Additional Information Regarding Physical Security Plan Review for License Renewal Project stage: Response to RAI ML16193A6812016-07-0707 July 2016 Purdue University School of Nuclear Engineering Notice of ADAMS Document Correction, PUR-1, Docket 50-182, ML16187A371. Technical Specifications, Proposed Amendment 13 Enclosed Project stage: Request ML16207A4262016-07-19019 July 2016 Purdue University Responses to Request for Additional Information Re PUR-1 License Renewal and Power Uprate Project stage: Response to RAI ML16187A3712016-07-25025 July 2016 Purdue University - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-87 for the Purdue University Reactor Project stage: RAI ML16267A4652016-09-19019 September 2016 Purdue University - Response to Request for Additional Information Regarding the Reactor License Renewal Application, Responses to Letter Dated July 25, 2016 Project stage: Response to RAI ML16277A1652016-09-29029 September 2016 Purdue University - Explanation of Technical Specification Changes and Emergency Operator Action Project stage: Other ML16265A6322016-10-21021 October 2016 Purdue University Environmental Assessment and Finding of No Significant Impact Regarding Renewal of Facility Operating License No. R-87 for the Purdue University Reactor (Letter) Project stage: Other ML16265A6342016-10-21021 October 2016 Purdue University - Notice of Issuance of Environmental Assessment and Finding of No Significant Impact Regarding the Renewal of Facility Operating License No. R-87 (FRN) Project stage: Request ML16267A0012016-10-31031 October 2016 Technical Specifications - Amendment 13 for the Purdue University Reactor, PUR-1 Project stage: Request ML16267A0002016-10-31031 October 2016 Renewal of the Facility Operating License for the Purdue University Research Reactor, PUR-1 Project stage: Request ML16264A0862016-11-0101 November 2016 Purdue University - Issuance of Renewed Facility Operating License No. R-87 for the Purdue University Reactor - Letter to Licensee Project stage: Approval 2012-06-29
[Table View] |
Text
PURDUE UNIVERSITY SCHOOL OF NUCLEAR ENGINEERING 1 June 2012 Document Control Desk US Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852 Attn: Ms. Cindy Montgomery, Research & Test Reactors (NRR/DPR/PRLB), Mailstop 012 D20
SUBJECT:
PURDUE UNIVERSITY - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE PURDUE UNIVERSITY REACTOR LICENSE RENEWAL (TAC NO. ME 1594),
RESPONSES TO RAIs (ML103400115 and ML103400250)
Dear Ms. Montgomery:
Enclosed please find the responses to the Request for Additional Information regarding the Purdue University Reactor License Renewal dated 6 July 2011. Included with this submission are responses to questions 43, 51, 56, 60, and 61. Should you have any questions or require further information, please don't hesitate to call me at 765.496.3573, or e-mail at jere@purdue.edu.
I hereby certify under penalty of perjury with my signature below that the information contained in this submission is true and correct to the best of my knowledge.
irector of Radiation Laboraitories Attachments: As described.
Cc:
Duane Hardesty, USNRC Project Manager Leah Jamieson; Purdue University College of Engineering Jim Schweitzer, Purdue University REM Ahmed Hassanein, Purdue NE School of Nuclear Engineering Nuclear Engineering Building N 400 Central Drive m West Lafayette, IN 47907-2017 (765) 494-5739 [ Fax: (765) 494-9570 m https://engineering.purdue.edu/NE
PUR-1: Partial Response to RAIs for license renewal (ML103400115 and ML103400250)
REQUESTED ADDITIONAL INFORMATION IN RESPONSE TO RAIs REGARDING THE PURDUE UNIVERSITY REACTOR LICENSE RENEWAL (TAC NO. ME 1594)
- 43. Please describe any changes that have occurred to the PUR-1 facility since the PUR-1 SAR dated July 7, 2008, was submitted to the NRC that may impact the safety conclusions of the SAR.
Response
There have been no changes to the PUR-1 facility since 7 July 2008 that would impact the safety conclusions of the SAR.
- 51. Section 3.5 of the SAR describes emergency procedures related to the air conditioner drain from the condensate holdup tank. Please describe the required actions if contamination is suspected and the method to dispose of any radioactive condensate if contamination is confirmed.
Response
If contamination is suspected, the condensate water will be analyzed utilizing the same procedures that are used for the periodic analysis of the reactor water. If contamination is confirmed, the water will be properly disposed of by the university's Department of Radiological and Environmental Management in accordance with federal, state and local laws, as is all of the other waste generated in work performed at the university.
- 56. NUREG-1537, Section 11.1.4 provides guidance for radiation monitoring and surveying. SAR Section 11.1.6 addresses monthly wipe tests and water samples, but does not stipulate how the program avoids, prevents, and remedies the occurrence and spread of contamination.
Please describe specific contamination control training and a contamination control program with provisions for recordkeeping sufficient in content and retention to support cleanup of contamination, maintenance, and planning for eventual decommissioning.
Response
PUR-1 utilizes the Purdue University radiation safety program, as set forth by university policy and the Radiation Safety Manual (http://www.purdue.edu/rem/home/booklets/radman.pdf), which complies with requirements of the relevant parts of Title 10 of the Code of Federal Regulations and Title 410 Part 5 of the Indiana Administrative Code. Initial training of reactor personnel is performed by the Department of Radiological and Environmental Management (REM). This includes such topics as contamination control and record keeping. The reactor staff is supported by REM health physicists and technicians during reactor operations where exposures and contamination are possible. Record keeping is maintained both at the reactor and REM offices.
- 60. NUREG-1537, Section 8 discusses the need for emergency electrical power systems to systems that ensure radiation doses are maintained ALARA and are within the regulatory Page 1 of 3 1 June 2012
PUR-1: Partial Response to RAIs for license renewal (ML103400115 and ML103400250) limits of 10 CFR Part 20. Please discuss pertinent design bases details related to emergency electrical power, such as:
A. The status of the reactor ventilation system/exhaust during normal operation, and what would happen to the ventilation system in the event of a loss of electrical power to the facility during operations, maintenance, or fuel handling, or in the event of an emergency.
B. The reactor ventilation connections to the HVAC system for the rest of the Duncan Annex and including whether operation is continuous related to emergency electrical power.
C. The conditions under which reactor ventilation system/exhaust would be isolated, and whether it can be isolated under loss of electrical power to the facility.
D. The fail position for the reactor ventilation system/exhaust dampers related to a loss of electrical power.
PUR-1 does not have emergency electrical power. Pertinent to the question, however, we note the following:
A. The reactor ventilation system exhausts to the roof of the building through a HEPA filter, as noted in the SAR and responses to previous questions. In the event of loss of electrical power, fans will stop, and inlet and outlet dampers will close, which is equivalent to the isolation switch on the operations console.
B.
The reactor ventilation system is separate and not connected to any other HVAC system in the Duncan Annex. Loss of electrical power will result in shutdown of the fans, and closing of the inlet and outlet dampers.
C.
In the event of an accident in the reactor room where there is the danger of airborne contamination, the isolation/shutdown switch would be thrown and the reactor console, which would shutdown the fans and close the dampers. This would be equivalent to a loss of power.
D. The fail position of the ventilation system and dampers is off/closed.
- 61. Section 13.2.1 of the SAR states that the reactor staff would evacuate the facility within 1.5 minutes in the event of an accident. Please provide substantiation for this time estimate and discuss other pertinent details such as:
A. Radiation alarms in the building to alert the occupants of events requiring evacuation.
B. An evacuation plan for students, faculty and staff and whether periodic evacuation drills are conducted to validate the stated evacuation times.
C. The responsible authority that would order and direct the building evacuation in the event in the reactor that would require an evacuation.
D. The exact areas that would be evacuated in the event in the reactor that would require an evacuation E. The conditions, if any, that would require the entire building be evacuated and how long would it take to complete the evacuation. Also, include how the evacuation is verified complete.
Response
The facility boundary is the reactor room. The room itself measures approximately 30 x 40 feet, and has two easily accessible exits on opposite ends of the room. Therefore, 1.5 minutes is a completely reasonable estimate for evacuation should that become a necessity. The other details are as follows:
Page 2 of 3 1 June 2012 Page 2 of 3 1 June 2012
PUR-A: Partial Response to RAIs for license renewal (M L103400115 and M L103400250)
A. There is an alarm in the reactor room, and a separate alarm out in the hallway of the nuclear engineering laboratories in the Duncan Annex basement that can be triggered from inside the reactor room.
B.
Evacuation drills are not conducted. The evacuation plan is listed in the reactor emergency procedure, which all reactor operators and those granted unescorted access privileges much be familiar with. These plans and procedures are commensurate with the size of the facility and the risks present.
C. As outlined in the Emergency Plan submitted with the SAR, the Emergency Director is responsible for determining the necessity of and making the order for building evacuation.
D. The reactor room, which is the facility boundary, is the only room that would be required to be evacuated under credible emergency conditions.
E. A fire in the building, or a bomb threat, are the only credible conditions that would require evacuation of the entire building. The evacuation of the facility would be verified by the reactor Emergency Director or designated alternate. The building would be verified by university police or fire emergency personnel.
Page 3 of 3 1 June 2012 Page 3 of 3 1 June 2012
1 June 2012 Document Control Desk US Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852 Attn: Ms. Cindy Montgomery, Research & Test Reactors (NRR/DPR/PRLB), Mailstop 012 D20
SUBJECT:
PURDUE UNIVERSITY - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE PURDUE UNIVERSITY REACTOR LICENSE RENEWAL (TAC NO. ME 1594),
RESPONSES TO RAIs (ML103400115 and ML103400250)
Dear Ms. Montgomery:
Enclosed please find the responses to the Request for Additional Information regarding the Purdue University Reactor License Renewal dated 6 July 2011. Included with this submission are responses to questions 43, 51, 56, 60, and 61. Should you have any questions or require further information, please don't hesitate to call me at 765.496.3573, or e-mail at jere@purdue.edu.
I hereby certify under penalty of perjury with my signature below that the information contained in this submission is true and correct to the best of my knowledge.
Very respectfully, Jere H. Jenkins Director of Radiation Laboratories Attachments: As described.