ML120960070

From kanterella
Jump to navigation Jump to search

Reed College - E-mail Dated 3/1/2012 from M. Krahenbuhl, Director to G. Wertz, NRC Project Manager Confirming Typographical Errors in TS for License Renewal (Tac No. ME1583)
ML120960070
Person / Time
Site: Reed College
Issue date: 03/01/2012
From: Krahenbuhl M
Reed College
To: Geoffrey Wertz
Research and Test Reactors Licensing Branch
Wertz, Geoffrey; NRR/DPR/301-415-0893
References
TAC ME1583
Download: ML120960070 (1)


Text

From: Melinda Krahenbuhl [mkrahenb@reed.edu]

Sent: Thursday, March 01, 2012 12:03 PM To: Wertz, Geoffrey

Subject:

Re: RRR TS Items

Geoff, The proposed changes are acceptable.

Thank you, Melinda Krahenbuhl Director Reed Research Reactor (503) 517-7748 On 3/1/12 7:25 AM, Wertz, Geoffrey wrote:

Melinda, our review of the RRR Technical Specifications (submitted via your letter dated Jan.

27, 2012) identified the following minor typographical items that should be corrected:

1. TS Section 1 Definitions, pg 2, Moveable Experiment - replace maybe with may be
2. TS 3.1.4, Fuel Parameters, pg 9, Specifications, 1st sentence - replace operate with be operated
3. TS 3.3, Reactor Primary Pool Water, pg 14, Specification e. - replace Table 2, Column 3 with Table 3 for radioisotopes with half-lives greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> I will make these changes in the final TSs provided to you with your license renewal if you provide a response to this email message indicating that the above proposed changes are acceptable to you. This email and your response will be made publicly available in ADAMS.

Thanks Geoffrey A. Wertz, P.E.

Project Manager Research and Test Reactors U.S. Nuclear Regulatory Commission Work (301) 415-0893 Fax (434) 384-0726 geoffrey.wertz@nrc.gov

The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location.