Acceptance Review Determination Relief Request for Repair of CRD Housing Penetrations
ML110950292
Person / Time
Site: Nine Mile Point 
(DPR-063)
Issue date: 04/05/2011
From: Richard Guzman
Division of Operating Reactor Licensing
To: Vandeputte D
Nine Mile Point
Guzman R, NRR/DORL, 415-1030
References
TAC ME5789
Download: ML110950292 (2)


Text

From:

Guzman, Richard To:

"Vandeputte, Dennis E" Cc:

Dosa, John J

Subject:

RE: NMP Unit 1 Relief Request - CRD Housing Penetration Weld Repair (ME5789)

Date:

Tuesday, April 05, 2011 11:27:00 AM

Dennis, The purpose of this e-mail is to provide the results of the NRC staffs acceptance review of the subject NMPNS application dated March 4, 2011. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed the application and concludes that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment.

This message will be added to ADAMS as an official agency record. If you have any questions, please contact me.

Rich Guzman Sr. Project Manager NRR/DORL US NRC 301-415-1030 Richard.Guzman@nrc.gov

From: Vandeputte, Dennis E [1]

Sent: Monday, March 07, 2011 8:50 AM To: Guzman, Richard Cc: Dosa, John J

Subject:

NMP Unit 1 Relief Request - CRD Housing Penetration Weld Repair

Rich Attached please find a copy of a relief request for NMP Unit 1. This request describes a weld repair strategy for NMP Unit 1 reactor vessel control rod drive (CRD) housing penetrations (stub tubes).

NRC review and approval is requested to support future CRD housing penetration weld repair contingency planning. A copy of an AREVA calculation (Attachment 3 of the submittal) is also attached, but I have not included the proprietary version (Attachment 5 of the submittal). Please let me know if there are any problems with this transmittal.

Dennis

>>> This e-mail and any attachments are confidential, may

contain legal, professional or other privileged information, and are intended solely for the addressee. If you are not the intended recipient, do not use the information in this e-mail in any way, delete this e-mail and notify the sender. CEG-IP2