ML110250611
| ML110250611 | |
| Person / Time | |
|---|---|
| Site: | Calvert Cliffs (DPR-053, DPR-069) |
| Issue date: | 01/10/2011 |
| From: | David Silk Operations Branch I |
| To: | Constellation Energy Nuclear Group |
| Hansell S | |
| Shared Package | |
| ML103200039 | List: |
| References | |
| TAC U01839 | |
| Download: ML110250611 (2) | |
Text
ES-301 Administrative Topics Outline Form ES-301-1 Facility: Calvert Cliffs Nuclear Power Plant Date of Examination: January 2011 Exam Level: SRO-I Operating Test No.: 2011 Type Administrative Topic (see Note)
Describe activity to be performed Code*
SRO-Admin-l: Ability to perform a review of plant tests and determine required plant actions.
Conduct of Operations N,R 2.1.7 - Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation. (4.4,4.7)
SRO-Admin-2: Ability to determine the time to perform required actions during abnormal or emergency plant operations.
Conduct ofOperations N,R 2.1.25 - Ability to interpret reference materials, sw::h as graphs, curves, tables, etc. (3.9,4.2)
SRO-Admin-3: Ability to apply Technical Specifications for a system.
Equipment Control N,R 2.2.12 Knowledge of surveillance procedures (3.7,4.1)
SRO-Admin-4: Determine radiological conditions for personnel exposure.
Radiation Control N,R 2.3.7 Ability to comply with radiation work permit requirements during normal or abnormal conditions. (RO 3.5, SRO 3.6)
SRO-Admin-5: Determine the appropriate emergency response actions per the ERPIP Emergency Procedures / Plan N,R 2.4.38 Ability to take actions called for in the facility emergency plan, including supporting or acting as emergency coordinator if required. (2.4, 4.4)
NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank 3 for ROs; :S 4 for SROs & RO retakes)
(N)ew or (M)odified from bank (2: 1)
(P)revious 2 exams (:S 1; randomly selected)
ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Calvert Cliffs Nuclear Power Plant Date of Examination: January 2011 Exam Level: SRO-I Operating Test No.: 20 II Control Room Systems@ (7 for SRO-I)
I Safety System I JPM Title Type Code*
Function
- a.
Sim-l: Verify Reactivity Control Safety Function 004.A2.14 Emergency Boration (3.8, 3.9)
ANS I
- b.
Sim-2: Unisolable CVCS leak 002.A2.01 Loss of coolant inventory (4.3, 4.4)
ANS 2
- c.
Sim-3: LOCA with a loss of ECCS flow path 06.A2.11 Rupture ofthe ECCS header (4.0, 4.4)
ANS 3
- d.
Sim-4: Verify Turbine Trip 45.A3.04 Ability to monitor automatic operation of the MTiG system, ANS 4 (Secondary) I including: TIG trip (3.4, 3.6)
- e.
Sim-5: Respond to a Faulted SIG 035.A2.01 Faulted or ruptured SIGs (4.5, 4.6)
ANS 4 (Primary)
- f.
Sim-6: Respond to the loss of a 120 volt vital AC bus NS 6
062.A2.04 Effect on plant of de-energizing a bus (3.1,3.4) i
- g.
Sim-7: Override shut a PORV that is open due to instrument malfunction 007.A2.01 Stuck-open PORV or code safety (3.9, 4.2)
ALNS 5
In-Plant Systems@ 3 for SRO-I
! h.
Plant-I: Ability to manually operate systems ENLR 8
00S.A4.07 Control of minimum level in the CCWS surge tank (2.9, 2.9)
- i.
Plant-2: Deenergize an instrumentation cabinet ENN 2
013.A2.06 Inadvertent ESFAS actuation (3.7, 4.0)
- j.
Plant-3: Ability to manually operate systems DEL 4 (Secondary) 076.A4.02 SWS valves (2.6, 2.6) d SRO-I control room (and in-plant) systems must be different and serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for SRO-I Required Actual (A)lternate path 4-6 6
(C)ontrol room
0 (D)irect from bank
~8 2
(E)mergency or abnormal in-plant 2:1 2
(EN)gineered safety feature
1 (L)ow-Power / Shutdown 2:1 3
(N)ew or (M)odified from bank including leA) 2:2 8
(P)revious 2 exams
~ 3 (randomly selected) 0 (R)CA 2:1 1
(S)imulator
7