Letter Sequence Acceptance Review |
|---|
|
|
MONTHYEARML1023006412010-08-16016 August 2010 10 CFR 50.55a Request Number RR-12, Request for Relief from Code Case N-722 Visual Examination of the Reactor Vessel Hot Leg Nozzle to Safe End Dissimilar Metal Welds Project stage: Request ML1026500132010-09-21021 September 2010 Acceptance Review E-mail, Relief Request RR-12, from Requirements of ASME Code Case N-722 Visual Examination of Reactor Vessel Hot-Leg Nozzle to Safe End Dissimilar Metal Welds for 4th 10-Year Inservice Inspection Interval (ME4541) Project stage: Acceptance Review ML1027801882010-10-0404 October 2010 Email, Draft Request for Additional Information, Relief Request RR-12, from Requirements of ASME Code Case N-722 for Fourth 10-Year Inservice Inspection Interval (ME4541) Project stage: Draft RAI ML1027801902010-10-0404 October 2010 Draft Request for Additional Information, Relief Request RR-12, from Requirements of ASME Code Case N-722 for Fourth 10-Year Inservice Inspection Interval (ME4541) Project stage: Draft RAI ML1028600872010-10-25025 October 2010 Request for Additional Information, Relief Request RR-12 from ASME Code Case N-722 Visual Examination Requirements for 4th 10-Year Inservice Inspection Interval Project stage: RAI ML1029101312010-10-25025 October 2010 Request for Withholding Information from Public Disclosure, 7/30/10 Affidavit Executed by J. Gresham, Westinghouse Project stage: Withholding Request Acceptance LIC-10-0095, Response to Request for Additional Information (RAI) Regarding Relief from ASME Code Case N-722 Requirements for Visual Examination of Reactor Vessel Hot Leg Nozzle to Safe End Welds2010-11-0404 November 2010 Response to Request for Additional Information (RAI) Regarding Relief from ASME Code Case N-722 Requirements for Visual Examination of Reactor Vessel Hot Leg Nozzle to Safe End Welds Project stage: Response to RAI ML1102001932011-01-14014 January 2011 Withdrawal of Response to Request for Additional Information (RAI) Regarding Request for Relief from ASME Code Case N-722 Requirements for Visual Examination of Reactor Vessel Hot Leg Nozzle-to-Safe End Dissimilar Metal Butt Welds Project stage: Withdrawal ML1104705872011-02-16016 February 2011 Request for Additional Information LAR to Revise Technical Specification to Relocate Operating and Surveillance Requirements for the Power Operated Relief Valve Project stage: RAI ML1104705882011-02-16016 February 2011 Request for Additional Information Project stage: RAI ML1105404412011-02-23023 February 2011 Request for Additional Information, Round 2, Relief Request RR-12 from ASME Code Case N-722 Visual Examination Requirements for 4th 10-Year Inservice Inspection Interval Project stage: RAI ML1105404492011-02-23023 February 2011 Request for Additional Information, Round 2, Relief Request RR-12 from ASME Code Case N-722 Visual Examination Requirements for 4th 10-Year Inservice Inspection Interval Project stage: RAI ML1106102172011-03-0303 March 2011 Request for Additional Information, Round 2, Relief Request RR-12 from ASME Code Case N-722 Visual Examination Requirements for 4th 10-Year Inservice Inspection Interval Project stage: RAI LIC-11-0016, Response to Second NRC Request for Additional Information (RAI) Regarding Request for Relief from ASME Code Case N-722 Requirements for Visual Examination of Reactor Vessel Hot Leg Nozzle-to-Safe End Dissimilar Metal Butt Welds2011-03-0404 March 2011 Response to Second NRC Request for Additional Information (RAI) Regarding Request for Relief from ASME Code Case N-722 Requirements for Visual Examination of Reactor Vessel Hot Leg Nozzle-to-Safe End Dissimilar Metal Butt Welds Project stage: Request ML1109103272011-04-0505 April 2011 Verbal Authorization, Request for Relief from Code Case N-722 Visual Examination of the Reactor Vessel Hot-Leg Nozzle-to-Safe-End Dissimilar Metal Welds, 4th 10-Year Inservice Inspection Interval Project stage: Approval ML1108309472011-05-17017 May 2011 Request for Withholding Information from Public Disclosure, Affidavit Dated 7/30/10, Executed by J. Gresham, Westinghouse, Report LTR-PAFM-10-123-P, Revision 0 Project stage: Withholding Request Acceptance ML1122702902011-08-18018 August 2011 Relief Request RR-12 from Code Case N-722, Additional Examinations for PWR Pressure Retaining Welds in Class 1 Components Fabricated with Alloy 600/82/182 Materials, Fourth 10-Year Inservice Inspection Interval Project stage: Approval LIC-12-0004, Delay 2012 Refueling Outage and Extend In-service Inspection (ISI) and In-service Test (IST) Intervals2012-01-17017 January 2012 Delay 2012 Refueling Outage and Extend In-service Inspection (ISI) and In-service Test (IST) Intervals Project stage: Other 2011-02-16
[Table View] |
Text
From:
Wilkins, Lynnea Sent:
Tuesday, September 21, 2010 4:54 PM To:
HANSHER, BILL R Cc:
Burkhardt, Janet; Lent, Susan; Markley, Michael; Collins, Jay; Lupold, Timothy
Subject:
ME4541 - Acceptance of FCS Request for Relief from Code Case N-722 Visual Examination of the Reactor Vessel Hot Leg Nozzle to Safe End Dissimilar Metal Welds
- Bill, By letter dated August 16, 2010, Omaha Public Power District submitted a Request for Relief from Code Case N-722 Visual Examination (VE) of the Reactor Vessel Hot Leg Nozzle to Safe End Dissimilar Metal Welds for the Fort Calhoun Station, Unit No. 1 (FCS). The relief request proposes an alternative to the American Society of Mechanical Engineers (ASME), Code Section XI, Code Case N-722 VE requirements. Specifically, OPPD proposes to credit (1) augmented examinations performed during previous refueling outages, (2) deterministic analyses of crack growth with positive results, and (3) the addition of zinc to the reactor coolant system to mitigate primary water stress corrosion cracking in lieu of the VE required by Code Case N-722.
The purpose of this letter is to provide the results of the NRC staff's acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review.
The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
Pursuant to Sections 50.55a(a)(3)(i) and 50.55a(a)(3)(ii) of Title 10 of the Code of Federal Regulations (10 CFR), the applicant shall demonstrate that the proposed alternatives would provide an acceptable level of quality and safety, or that compliance with the specified requirements of Section 50.55a would result in hardship or unusual difficulty without a compensating increase in the level of quality or safety.
The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the staff to proceed with its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Please note, the NRC staff has determined a need for substantive requests for additional information (RAIs) to complete the technical review. You will be advised of these RAIs by separate correspondence.
If you have any questions, please contact the me.
Lynnea Wilkins, Project Manager Fort Calhoun Station, Unit 1 Cooper Nuclear Station Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation US Nuclear Regulatory Commission
Phone: 301-415-1377 E-mail Properties Mail Envelope Properties (F371D08C516DE74F81193E6D891DC4AF3874D23FFA)
Subject:
ME4541 - Acceptance of FCS Request for Relief from Code Case N-722 Visual Examination of the Reactor Vessel Hot Leg Nozzle to Safe End Dissimilar Metal Welds Sent Date: 9/21/2010 4:54:30 PM Received Date: 9/21/2010 4:54:30 PM From: Wilkins, Lynnea Created By: Lynnea.Wilkins@nrc.gov Recipients:
bhansher@oppd.com (HANSHER, BILL R)
Tracking Status: None Janet.Burkhardt@nrc.gov (Burkhardt, Janet)
Tracking Status: None Susan.Lent@nrc.gov (Lent, Susan)
Tracking Status: None Michael.Markley@nrc.gov (Markley, Michael)
Tracking Status: None Jay.Collins@nrc.gov (Collins, Jay)
Tracking Status: None Timothy.Lupold@nrc.gov (Lupold, Timothy)
Tracking Status: None Post Office:
HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 12793 9/21/2010 Options Expiration Date:
Priority: olImportanceNormal ReplyRequested: True Return Notification: False Sensitivity: olNormal Recipients received: