From:

Feintuch, Karl Sent:

Thursday, August 05, 2010 11:29 AM To:

'Jack Gadzala' Cc:

Bedi, Gurjendra

Subject:

RE: Snubber Replacement Reporting I contacted the cognizant technical branch (CPTB = Component Performance and Testing Branch) about this matter and identified the affected items to them:

Containment Spray 6 inch line (qty 1)

Reactor Coolant System 2 inch line (qty 2)

CVCS 2 inch line (qty 1)

Safety Injection 2 inch line (qty 1)

Your action to enter this condition into the Kewaunee Power Station corrective action program and include the missing (replaced) snubbers in the next routine report is acceptable.

Karl Feintuch Project Manager USNRC 301-415-3079 From: Jack Gadzala [1]

Sent: Monday, August 02, 2010 2:50 PM To: Feintuch, Karl

Subject:

Snubber Replacement Reporting

Karl, Attached is the KPS 2009 ISI Summary Report that was submitted to NRC on January 4, 2010.

As we discussed, 5 snubber replacements were not included in that report (Form NIS-2 Owners Report For Repair/Replacement Activity) as required by paragraph IWA-6230 of ASME Section XI. This condition has been entered into the KPS corrective action program. Unless the staff desires the information sooner, we plan to report the 5 snubber replacements in the next routine report.

Jack Dominion KPS Licensing 920-388-8604 CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and

may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.

E-mail Properties Mail Envelope Properties (26E42474DB238C408C94990815A02F090A76C3F588)

Subject:

RE: Snubber Replacement Reporting Sent Date: 8/5/2010 11:33:29 AM Received Date: 8/5/2010 11:33:00 AM From: Feintuch, Karl Created By: Karl.Feintuch@nrc.gov Recipients:

jack.gadzala@dom.com ('Jack Gadzala')

Tracking Status: None Gurjendra.Bedi@nrc.gov (Bedi, Gurjendra)

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 12514 8/5/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: