Completion of License Renewal Commitment 41 Re Fatigue Analysis of Surge Line Hot Leg Nozzle. Report No. 0900090.401 Enclosed
ML101610233
Person / Time
Site: Kewaunee 
(DPR-043)
Issue date: 06/01/2010
From: Hartz L
Dominion Energy Kewaunee
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
10-324
Download: ML101610233 (4)


Text

Dominion Energy Kewaunee, Inc.

5000 Dominion Boulevard, Glen Allen, VA 23060 June 1, 2010 United States Nuclear Regulatory Commission Serial No.:

10-324 Attention: Document Control Desk LR/MWH RO Washington, DC 20555-0001 Docket No.: 50-305 License No.: DPR-43 DOMINION ENERGY KEWAUNEE, INC.

KEWAUNEE POWER STATION COMPLETION OF KEWAUNEE POWER STATION LICENSE RENEWAL COMMITMENT 41 By letter dated July 13, 2009 (Reference 1), the NRC requested additional information regarding the aging management programs and metal fatigue time-limited aging analyses (TLAA) included in the license renewal application (LRA) for Kewaunee Power Station (KPS) (Reference 2). By letter dated August 17, 2009 (Reference 3), Dominion Energy Kewaunee, Inc. (DEK) stated that a final response to RAI B3.2-2 (from Reference 1) would be submitted following re-analysis of locations that were initially evaluated using stress-based fatigue monitoring methods but are also subject to the environmental effects on fatigue usage in accordance with NUREG/CR-6260, "Application of NUREG/CR-5999 Interim Fatigue Curves to Selected Nuclear Power Plant Components." By letter dated February 2, 2010 (Reference 4), DEK provided a final response to RAI B3.2-2. This response consisted of a commitment as follows:

Commitment 41 "Perform a fatigue analysis of the surge line hot leg nozzle and the charging line nozzle in accordance with ASME B&PV Code Section III, Subsection NB-3200 guidance and determine the CUF [Cumulative Usage Factor], considering the effects of the reactor coolant environment. Confirm that CUF is less than 1.0 at the end of 60 years of plant operation."

Schedule: Prior to the Period of Extended Operation.

During a subsequent discussion, the NRC staff requested that DEK complete the fatigue analysis prior to issuance of the KPS License Renewal safety evaluation report (SER) to allow the NRC to review the analysis results. As a result, DEK agreed to complete the fatigue analysis prior to SER issuance and provide a summary of the analysis methodology and results for NRC review. provides the vendor-prepared summary report of the requested fatigue analysis. The analysis results show acceptable fatigue usage for the NUREG/CR-6260 required locations for which stress-based fatigue monitoring methods (EPRI FatiguePro) 04~-

Serial No.10-324 Docket No. 50-305 Page 2 of 4 were originally used as well as the consideration of the effects of the reactor coolant environment.

Performance of the fatigue analysis, with acceptable results, completes the actions committed to in response to RAI B3.2-2 and closes License Renewal Commitment 41.

Should you have any questions regarding this submittal, please contact Mr. Paul C.

Aitken at (804) 273-2818.

Very truly yours, Leslie N Hartz Vice President - Nuclear Support Services COMMONWEALTH OF VIRGINIA

))

COUNTY OF HENRICO

)

The foregoing document was acknowledged before me, in and for the County and State aforesaid, today by Leslie N. Hartz, who is Vice President - Nuclear Support Services of Dominion Energy Kewaunee, Inc. She has affirmed before me that she is duly authorized to execute and file the foregoing document in behalf of that Company, and that the statements in the document are true to the best of her knowledge and belief.

Acknowledged before me this 1*--

day of "i'3_1

,2010.

My Commission Expires:

N ý'\\r"

,R, YV O}#'C_

Notar' Public

-7: \\..aQs C"-rln I D tcoet ct

  • 1.;'C 0,-

C'l.r L.-.

d GINGER LYNN MELTON Notary Public Commonwealth of Virginia 310847 AAn /'*mmlr

-iee n J~nr.

A

,'nr 9nll***

7 V

F I

r -

Serial No.10-324 Docket No. 50-305 Page 3 of 4

Attachment:

Structural Integrity Associates, Inc. Report No. 0900090.401, Revision 0, "60-Year EAF Analyses Summary Report - Kewaunee Power Station - Charging Nozzle and RCS Hot Leg Surge Nozzle," dated May 2010.

References:

1. Letter from Samuel Hernandez (NRC) to David A. Heacock (DEK), "Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Aging Management Programs (TAC No. MD9408)," dated July 13, 2009. [ADAMS Accession No. ML091810958]
2. Letter from D. A. Christian (DEK) to NRC, "Kewaunee Power Station Application for Renewed Operating License," dated August 12, 2008. [ADAMS Accession No. ML082341020]
3. Letter from Stephen E. Scace (DEK) to NRC, "Response to Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Aging Management Programs," dated August 17, 2009. [ADAMS Accession No. ML092320093]
4. Letter from J. Alan Price (DEK) to NRC, "Response to Request for Additional Information for the Review of the Kewaunee Power Station License Renewal Application - Aging Management Review/Aging Management Programs," dated February 2, 2010. [ADAMS Accession No. ML100331879]

Commitments made in this letter:

None.

Serial No.10-324 Docket No. 50-305 Page 4 of 4 cc:

U.S. Nuclear Regulatory Commission Regional Administrator, Region III 2443 Warrenville Road Suite 210 Lisle, IL 60532-4532 Mr. P. S. Tam, Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint, Mail Stop 08-H4A 11555 Rockville Pike Rockville, MD 20852-2738 Mr. Daniel Doyle Environmental Project Manager U.S. Nuclear Regulatory Commission Mail Stop 0-11 F1 Washington, DC 20555-0001 Mr. John Daily License Renewal Project Manager U.S. Nuclear Regulatory Commission Mail Stop 0-11F1 Washington, DC 20555-0001 NRC Senior Resident Inspector Kewaunee Power Station N490 Highway 42 Kewaunee, WI 54216 Public Service Commission of Wisconsin Electric Division P.O. Box 7854 Madison, WI 53707 David Hardtke Chairman - Town of Carlton E2334 Lakeshore Road Kewaunee, WI 54216