Tennessee Valley Authority 1101 Market Street, LP 3R Chattanooga, Tennessee 37402-2801 R. M. Krich Vice President Nuclear Licensing April 30, 2010 10 CFR 50.4 10 CFR 50.36a ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296

Subject:

Annual Radioactive Effluent Release Report - 2009 In accordance with 10 CFR 50.36a(a)(2) and Browns Ferry Nuclear Plant (BFN) Technical Specification (TS) 5.6.3, the Tennessee Valley Authority (TVA) is submitting the BFN Annual Radioactive Effluent Release report for January through December 2009. Also, in accordance with the BFN Offsite Dose Calculation Manual (ODCM) Section 1.1.1, Action (b), and Section 1.1.2, Action (c), TVA is providing the BFN Inoperable Radioactive Effluent Instrumentation Report. provides the Radiological Impact Assessment Report. Enclosure 2 provides the Meteorological Data Tables. Enclosure 3 is the Effluent and Waste Disposal Annual Report, and Enclosure 4 is the Inoperable Radiological Effluent Instrumentation Report.

TVA revised the ODCM during calendar year 2009, as such; Enclosure 5 provides ODCM, Revision 20.

/10c~

printed on recycled paper

U.S. Nuclear Regulatory Commission Page 2 April 30, 2010 There are no commitments contained within this letter. If you have any questions concerning this submittal, please contact Terry Cribbe at (423) 751-3850.

Sincerely, R. M. Krich

Enclosures:

1. Radiological Impact Assessment, January - December 2009
2. Meteorological Data Tables, January - December 2009
3. Effluent and Waste Disposal Annual Report, January - December 2009
4. Inoperable Radiological Effluent Instrumentation Report, January - December 2009
5. Offsite Dose Calculation Manual, 0-ODCM-001, Revision 20 cc: (w/ Enclosure):

NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant Mr. Ronald Sanacore (w/Enclosures)

American Nuclear Insurers 95 Glastonbury Blvd.

Glastonbury, Connecticut 06033

ENCLOSURE1 RADIOLOGICAL IMPACT ASSESSMENT REPORT BROWNS FERRY NUCLEAR PLANT JANUARY THROUGH DECEMBER 2009 (See Attached)

El-I

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009

1. INTRODUCTION Potential doses to the "maximum exposed individual" and the population around Browns Ferry are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology for determining plant releases for the reporting period used to estimate dose is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for Browns Ferry.

I1. DOSE LIMITS The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.

The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:

< 5 mrad per quarter and

< 10 mrad per year for gamma radiation.

- and -

< 10 mrad per quarter and

< 20 mrad per year for beta radiation.

The dose limits to a Member of the Public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:

< 7.5 mrem per quarter and

< 15 mrem per year to any organ.

The dose or dose commitment to a Member of the Public from radioactive material in liquid effluents released to unrestricted areas are:

< 1.5 mrem per quarter and

< 3 mrem per year to the total body,

- and -

< 5 mrem per quarter and

< 10 mrem per year to any organ.

The limit for the total effective dose equivalent to an individual Member of the Public inside the site boundary is:

100 mrem per year.

The EPA limits for total dose to any Member of the Public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:

< 25 mrem per year to the whole body,

< 75 mrem per year to the thyroid,

- and -

< 25 mrem per year to any other organ.

E1-2

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009

[Il. DOSE CALCULATIONS Estimated doses to Members of the Public are determined using computer models (the Gaseous Effluent Licensing Code, GELC, and the Quarterly Water Dose Assessment Code, QWATA). These models are based on guidance provided by the NRC (in Regulatory Guides 1.109, 1.111 and 1.113) for determining.the potential dose to individuals and populations living in the vicinity of the plant. The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data. Many of these factors are obtained from NUREG/CR-1004. The values chosen will tend to overestimate the dose. The expected dose to actual individuals is lower. The calculated doses are presented in Tables 1, 2, 3, 4, 5, 6, 7, 8, and 9.

IV. DOSES FROM AIRBORNE EFFLUENTS For airborne effluents, Members of the Public can be exposed to radiation from several sources: direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by milk and beef animals.

Airborne Release Points There are four monitored release points from Browns Ferry Nuclear Plant: the turbine building, the radwaste building, the reactor building, and the stack.

Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from wind speeds and directions measured 10 meters above ground and from the vertical temperature difference between 10 and 45 meters, and are presented for each quarter in Tables 10, IH, 12, and 13.

Releases from the radwaste and reactor buildings are considered split-level releases. Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the vertical exit velocity to the horizontal wind speed. The split-level dispersion approach is implemented using a model that requires two complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JFD is based on wind speeds and directions measured 10 meters above ground-level and from the vertical temperature difference between 10 and 45 meters. The elevated portion of the split-level JFD is based on wind speeds and direction measurements at the 45 meter level and the vertical temperature difference between 45 and 91 meters. Both of these JFDs are given for each quarter in Tables 14, 15, 16, 17, 18, 19, 20, and 21.

Releases fromthe stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 91 meters and the vertical temperature difference between 45 and 91 meters, and are given for each quarter in Tables 22, 23, 24, and 25.

E1-3

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Meteorological Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed, wind direction, and temperature at heights of 10, 45, and 91 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.

The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers, the hills become larger to the north and south and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.

External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.

Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.

Organ Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways:

ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor. For the ingestion dose, however, only those pathways that exist for each receptor are considered in the sum, e.g., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.

The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Tables 1, 2, 3, and 4.

E1-4

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 V. DOSES FROM LIQUID EFFLUENTS For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).

The concentration of radionuclides in the Tennessee River is calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC (in Regulatory Guides 1.109) for maximum ingestion rates, exposure times, etc. Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.

Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.0.

Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release-point.

The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply [West Morgan - East Lawrence (WMEL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from Browns Ferry, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point. Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Tables 5, 6, 7, and 8 along with the average river flows past the plant site for the periods.

VI. POPULATION DOSES Population doses due to airborne effluents are calculated for an estimated 778,266 persons living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.

Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population.

Water ingestion population doses are calculated using actual population.figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.

Population doses calculated for airborne and liquid effluents are presented in Tables 1, 2, 3, 4, 5, 6, 7, and 8.

E1-5

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 VII. OFFSITE DIRECT RADIATION DOSE External gamma radiation levels were measured by environmental dosimeters deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP). The quarterly gamma radiation levels determined from these dosimeters during this reporting period averaged approximately 14 mrem/quarter at onsite (at or near the site boundary) stations and approximately 11 mrem/quarter at offsite stations or approximately 3 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of TVA nuclear plants where the average radiation levels onsite were generally 2-6 mrem/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences.

Fluctuations in natural background dose rates and in dosimeter readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.

VIII. DOSE TO A MEMBER OF THE PUBLIC INSIDE THE SITE BOUNDARY Pursuant to ODCM section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. This review assumed that onsite TVA employees engaged in work activities not associated with nuclear power electric generation were considered as members of the public.

The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose. The gaseous effluent dose commitment is negligible compared to the direct radiation dose.

The direct radiation dose was determined from area environmental dosimeters located onsite. It consisted of gamma dose from the plume, ground contamination, and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.). The critical location was determined to be a TLD near the Livewell Center (Training Center). The direct radiation dose accounting for background and occupancy was 1.4 mrem during 2009.

The total annual dose commitment to the member of the public for 2009 is 1.4 mrem, the direct radiation dose while in the site boundary. It can be concluded that the dose limit for a member of the public inside the site boundary as specified in 10 CFR 20.1301 was not exceeded.

E1-6

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 IX. TOTAL DOSE To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.

The annual dose to any organ other than thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than thyroid) to determine compliance.

The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.

Total dose from the fuel cycle is presented in Table 9.

E1-7

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 1 Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 4.9E-12 mrad 5 mrad

< 1%

NNW/1650 meters Beta Air 1.5E-1 I mrad 10 mrad

< I %

NNW/1650 meters Submersion Total Body 3.4E-05 mrem NA NA N/2000 meters Skin 3.9E-05 mrem NA NA N/2000 meters Organ Doses Child/Bone 8.OE-03 mrem 7.5 mrem

< I%

NNW/l1802 meters Child/Th roid 8.2E-03 mrem 7.5 mrem

<1%,

NNW/1 802 meters Child/Total Body 7.9E-03 mrem 7.5 mrem

<I %

NNW/l 802 meters Population Doses Total Body Dose 1.6E-02 man-rem Maximum Organ Dose (organ) 1.7E-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

E1-8

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 2 Doses from Airborne Effluents Second Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 9.3E-12 mrad 5 mrad

< 1%

WNW/3325 meters Beta Air 2.9E-II mrad 10 mrad

<I %

WNW/3325 meters Submersion Total Body 2.1E-04 mrem NA NA ESE/1860 meters

Skin, 2.4E-04 mrem NA NA ESE/1860 meters Organ Doses Child/Bone 2.8E-03 mrem 7.5 mrem

<I %

NNW/1802 meters Child/Thyroid 3.4E-03 mrem 7.5 mrem

< 1%

NNW/1802 meters Child/Total Body 2.7E-03 mrem 7.5 mrem

< 1%

NNW/1802 meters Population Doses Total Body Dose 1.1 E-02 man-rem Maximum Organ Dose (organ) 1.5E-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

E1-9

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 3 Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 9.3E-12 mrad 5 mrad

< 1%

S/2250 meters Beta Air 2.8E-I! mrad 10 mrad

< 1%

S/2250 meters Submersion Total Body 3.3E-05 mrem NA NA NNW/1639meters Skin 3.8E-05 mrem NA NA NNW/1639 meters Organ Doses Child/Bone 1.8E-03 mrem 7.5 mrem

< 1%

NNW/1802 meters Child/Thyroid 2.5E-03 mrem 7.5 mrem

< I %

NNW/1 802 meters Child/Total Body 1.8E-03 mrem 7.5 mrem

< 1%

NNW/1802 meters Population Doses Total Body Dose 9.0E-03 man-rem Maximum Organ Dose (organ) 1.3E-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

E1-10

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 4 Doses from Airborne Effluents Fourth Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 5.9E-12 mrad 5 mrad

< I %

WNW/6400 meters Beta Air 1.8E-1 I mrad 10 mrad

< 1%

WNW/6400 meters Submersion Total Body 6.1E-07 mrem NA NA E/1290 meters Skin 7.2E-07 mrem NA NA E/1290 meters Organ Doses Child/ Bone 2.0E-03 mrem 7.5 mrem

< 1%

NNW/1802 meters Child/Thyroid 2.5E-03 mrem 7.5 mrem

< 1%

NNW/] 802 meters Child/Total Body 2.0E-03 mrem 7.5 mrem

<I %

NNW/1802 meters Population Doses Total Body Dose 9.9E-03 man-rem Maximum Organ Dose (organ) 1.4E-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

E1-11

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 5 Doses from Liquid Effluents First Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 1.2E-03 Recreation 1.2E-04 Water Ingestion 9.4E-05 Total i.4E-03 1.5 mrem

< 1 %

Adult Liver Fish Ingestion 1.8E-03 Recreation 1.2E-04 Water Ingestion 1.OE-05 Total 2.OE-03 5 mrem

< 1 %

Child Thyroid Fish Ingestion 1.2E-06 Recreation 1.2E-04 Water Ingestion 9.7E-05 Total 2.2E-04 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 51398 Population Doses Total Body Dose

1. 1 E-02 man-rem Maximum Organ Dose (organ) 1.8E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

El-12

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 6 Doses from Liquid Effluents Second Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 6.8E-04 Recreation 1.4E-04 Water Ingestion 1.7E-04 Total 9.9E-04 1.5 mrem

< 1 %

Teen Liver Fish Ingestion 1.1 E-03 Recreation 1.4E-04 Water Ingestion 1.3E-04

__Total I.4E-03 5 mrem

<I %

Child Thyroid Fish Ingestion 2.6E-06 Recreation 1.4E-04 Water Ingestion 2.1 E-04 Total 3.5E-04 5 mrem

< I %

Average Riverflow past BFN (cubic feet per second): 46882 Population Doses Total Body Dose 1.2E-02 man-rem Maximum Organ Dose (organ) 1.5E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

E1-13

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 7 Doses from Liquid Effluents Third Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 3.9E-04 Recreation 5.OE-05 Water Ingestion 2.1 E-04 Total 6.5E-04 1.5 mrem

< 1 %

Child Liver Fish Ingestion 5.4E-04 Recreation 5.OE-05 Water Ingestion 2.9E-04 Total 8.8E-04-"

5 mrem

< 1 %

Child Thyroid Fish Ingestion 3.3E-06 Recreation 5.OE-05 Water Ingestion 2.7E-04 Total 3.2E-04 5 mrem

< 1%

Average Riverflow past BFN (cubic feet per second): 31472 Population Doses Total Body Dose 9.IE-03 man-rem Maximum Organ Dose (organ) 1.1 E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

E1-14

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 8.

Doses from Liquid Effluents Fourth Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 1.7E-04 Recreation

2. 1 E-05 Water Ingestion 7.7E-05 Total 2.7E-04 1.5 mrem

< 1 %

Child Liver Fish Ingestion 2.3E-04 Recreation 2.1 E-05 Water Ingestion

1. 1 E-04 Total 3.6E-04 5 mrem

< 1 %

Child Thyroid Fish Ingestion 1.2E-06 Recreation 2.1 E-05 Water Ingestion 1.OE-04 Total 1.2E-04 5 mrem

<1 %

Average Riverflow past BFN (cubic feet per second): 91346 Population Doses Total Body Dose 3.2E-03 man-rem Maximum Organ Dose (organ) 4.1 E-03 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

El-15

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2009 Table 9 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter-Quarter Total Body or any Organ (except thyroid)

Total body air submersion 3.4E-05 2.IE-04 3.31E-05 6.1E-07 Critical organ dose (air) 8.0E-03 2.8E-03 1.8E-03 2.OE-03 Total body dose (liquid) 1.4E-03 9.9E-04 6.5E-04 2.7E-04 Maximum organ dose (liquid) 2.0E-03 1.4E-03 8.8E-04 3.6E-04 Direct Radiation Dose 0

0 0

0 Total 1.1E-02 5.4E-03 3.4E-03 2.6E-03 Cumulative Total Dose (mrem)

(Total body or any other organ) 2.2E-02 Annual Dose Limit (mrem) 2.5E+01 Percent of Limit

<1%

Thyroid Dose (mrem)

Total body air submersion 3.4E-05 2.1E-04 3.3E-05 6.]E-07 Thyroid dose (airborne) 8.2E-03 3.4E-03 2.5E-03 2.5E-03 Total body dose (liquid)

I.4E-03 9.9E-04 6.5E-04 2.7E-04 Thyroid dose (liquid) 2.2E-04 3.5E-04 3.2E-04 1.2E-04 Direct Radiation Dose 0

0 0

0 Total 9.9E-03 5.OE-03 3.5E-03 2.9E-03 Cumulative Total Dose (Thyroid) mrem 2.1E-02 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit

<I %

E1-16

ENCLOSURE 2 METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 E2-1

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 10 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER E2-2

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.420 0.280 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.839 0.047 0.140 0.000 0.000 0.000 0.093 0.513 0.699 1.166 0.233 0.093 0.140 0.000

0. 000 0.000 0.000 3.124 0.047 0.047 0.000 0.000 0.000 0.000 0.280 0.000 0.186 0.093 0.000 0.047 0.000 0.000 0.093 0.000 0.793 0.793 0.326 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.140 0.233 1.632 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.233 0.233 0.513 0.000 0.000 0.000 0.000 0.000

-0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.233 0.280 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.886 0.513 0.047 0.000 0, 0oo 0.093 0.839 1.119 1.632 0.420 0.093 0.186 0.047 0.093 0.513 0.699 7.179 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 154 154 2145 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03'AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/05/19 MEAN WIND SPEED =

7.04 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-3

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.093

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.140 0.000 0.047 0.000 0.000 0.047 0.093 0.233 0.047 0.186 0.000 0.047 0.000 0.000 0.093 0.000 0.932 0.047 0.047 0.140 0.000 0.000 0.047 0.000 0.000 0.140 0.000 0.000 0.000 0.047 0.047 0.093 0.000 0.606 0.233 0.140 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.233 0.280 0.373 0.140 1.585 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.140 0.047 0.373 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.093 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.420 0.186 0.280 0.000 0.000 0.093 0.140 0.280 0.280 0.186 0.000 0.140 0.280 0.559 0.793 0.186 3.823 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF OF CAL VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVAr LM 2145 82 82 2145 0

TIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/05/19 MEAN WIND SPEED =

8.66 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-4

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2009 -

MAR 31, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.186 0.140 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.420 0.047 0.047 0.000 0.000 0.047 0.093 0.140 0.326 0.093 0.186 0.093 0.047 0.047 0.186 0.000 0.047 1.399 0.140 0.140 0.140 0.000 0.047 0.000 0.000 0.000 0.000 0.186 0.000 0.047 0.093 0.280 0.047 0.047 1.166 0.373 0.233 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.280 0.373 0.186 1.632 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o.oo0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.606 0.420 0.233 0.000 0.093 0.140 0.326 0.466 0.140 0.373 0.093 0.140 0.186 0.746 0.513 0.280 4.755 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 102 102 2145 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/05/19 MEAN WIND SPEED =

6.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-5

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.047 0.000 0.000 0.000 0.000 0.047 0.047 0.140 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.373 0.093 0.093 0.233 0.140 0.093 0.233 0.746 1.352 0.466 0.559 0.233 0.233 0.420 0.093 0.186 0.140 5.315 0.420 0.746 0.839 0.326 0.326 0.699 0.699 0.513 0.979 0.466 0.140 0.140 0.373 0.373 0.420 0.280 7.739 0.559 0.466

0. 653 0.233 0.000 0.047 0.140 0.000
0. 653 0.186 0.186 0.093 0.186 0.280 0.606 0.326
4. 615 0.979 1.399 0.466 0.000 0.000 0.093 0.093 0.000 0.093 0.047 0.000 0.233 0.979 0.746 2.331 2.238 9.697 0.000 0.186 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.233 0.280 1.119 1.119 3.217 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.098
2. 890 2.284
0. 699 0.420 1.119 1.725 2.005 2.284 1.259 0.559 0.886 2.191 1.772 4.755 4.103 0.000 31.049 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 666 666 2145 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/05/19 MEAN WIND SPEED =

7.09 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-6

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/lao M)

Browns Ferry Nuclear Plant JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.047 0.140 0.000 0.000 0.047 0.000 0.140 0.186 0.140 0.093 0.093 0.000 0.000 0.047 0.000 0.093 0.420 0.420 0.466 0.373 0.466 0.793 1.538

1. 958
1. 911
0. 653 0.420 0.839 0.466 0.186 0.373 0.280 0.606 0.839 0.233 0.326 0.326 1.072 1.585 0.186 2.005
0. 653 0.093 0.047 0.513 0.093 0.047 0.793 9.417 0.326 0.513 0.326 0.233 0.000 0.000 0.000 0.000 1.772
0. 606 0.047 0.047 0.093 0.047 0.233
0. 653 4.895 0.140 0.093 0.140 0.047 0.000 0.000 0.047 0.000 0.373 0.140 0.000 0.047 0.280 0.047 0.233 0.839 2.424 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.047 0.047 0.186 0.000 0.000 0.000 0.000

.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.538 2.005 1.166 0.979 0.839 1.865 3.310 2.331 6.200 2.145

0. 653 1.026 1.352' 0.466
0. 932 2.704 1.026 11.562 0.000 29.510 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 633 633 2145 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/05/19 MEAN WIND SPEED =

4.31 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-7

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2009 -

MAR 31, 2009 WIND DIRECT ION N

NNE NE ENE E

E SE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.003

0. 002 0.001 0.002 0.004 0.004 0.007 0.013 0.005 0.002 0.001 0.001 0.000 0.001 0.000 0.001 0.047

>'24.5 TOTAL 0.140 0.093 0.093 0.047 0.186 0.093 0.466

0. 653 0.093 0.000 0.047 0.047 0.000 0.140 0.093 0.000
2. 191 0.513 0.373 0.047 0.326 0.606
0. 653
0. 932 1.911
0. 932 0.326 0.093 0.093 0.047 0.000 0.000 0.186 7.040 0.420 0.513 0.373 0.140 0.326 0.093 0.047 0.047 1.445 0.186
0. 000 0.000 0.000 0.000 0.047 0.513 4.149 0.000 0.373 0.000 0.000 0.000 0.000 0.000 0.000 0.746 0.093 0.000 0.000 0.000 0.000 0.000 0.047 1.259 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.420 0.000 0.000 0.*000 0.000 0.000 0.000 0.000 0.420 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.076 1.354 0.514 0.515 1.123 0.843 1.452 2.624
3. 642
0. 608 0.141 0.141 0.047 0.141 0.140 0.747 15.105 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 324 324 2145 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/05/19 MEAN WIND SPEED =

3.17 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-8

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH).

0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.233 0.140 0.047 0.093 0.233 0.280 0.466 0.746 0.000 0.047 0.000 0.047 0.000 0.000 0.047 0.093 2.471 0.559 0.280 0.420 0.140 0.047 0.140 0.466 1.585 1.119 0.000 0.000 0.000 0.000 0.000 0.000 0.047 4.802 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.979 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.166 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 932 0.420 0.466 0.233 0.280 0.420
0. 932 2.378 2.238 0.047 0.000 0.047 0.000 0.000 0.047 0.140 8.578 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 184 184 2145 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

2.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2009/05/19 E2-9

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 11 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER E2-10

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0'.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.231 0.692 0.738 0.876 0.507

0. 092 0.138 0.000 0.000 0.000 0.046 3.366 0.000 0.000 0.000 0.000 0.046 0.507
0. 968 0.323 0.323 0.184 0.092 0.277 0.277 0.000 0.000
0. 000 2.997 0.000 0.000 0.000 0.000 0.000 0.369 0.323 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.000 0.046
0. 922 0.046 0.092 0.138 0.000 0.000 0.000 0.138 0.000 0.000 0.000 0.000 0.138 0.369 0.645 0.415 0.184 2.167 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000
0. 000
0. 000 0.000 0.000 0.000 0.415 0.000 0.000 0.461 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.138 0.000
0. 092
1. 107 2.167 1.060 1.199 0.692 0.184 0.553 0.784 1.153 0.415 0.277 9.959 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2169 216 216 2169 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

5.67 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2009/08/06 E2-11

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/l00 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.323 0.369

0. 645 0.277 0.046 0.000 0.000 0.000 0.000 0.000 1.798
0. 000 0.000 0.000 0.000 0.000 0.184 0.231 0.046 0.000 0.046 0.138 0.415 0.323 0.000 0.000 0.046 1.429 0.046 0.000 0.046 0.000 0.092 0.184 0.000 0.000 0.000 0.000 0.000 0.000 0.184 0.184 0.231 0.092 1.060 0.184 0.138 0.277 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.507 0.645 0.184 2.029 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.138 0.000 0.277 0.000, 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.231
0. 138 0.323 0.000 0.092 0.507 0.553 0.415
0. 645 0.323 0.184 0.461 0.553 0.830 1.014 0.323 6.593 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2169 143 143 2169 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/08/06 MEAN WIND SPEED =

6.35 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-12

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.369 0.415 0.415 0.231 0.184 0.138 0.000 0.000 0.000 0.000 1.844 0.000 0.046 0.000 0.046 0.046 0.138

0. 138 0.000 0.046 0.138 0.000 0.415 0.369 0.231 0.046 0.000
1. 660 0.092 0.046 0.000 0.000 0.000 0.046 0.092 0.000 0.000 0.000 0.000 0.092 0.138 0.138 0.231 0.092
0. 968 0.046
0. 138 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.553 0.738 0.092 1.752 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.231 0.046 0.092 0.092 0.231 0.599 0.415 0.461 0.369 0.184 0.645 0.599 1.014 1.107 0.184 6.408 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2169 139 139 2169 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS

-WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/08/06 MEAN WIND SPEED =

5.91 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-13

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.184 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.092 0.277 0.092 0.231 0.231 0.968 1.337 0.968 1.614 1.475 0.922

0. 645 0.968 0.138 0.092 0.000 0.092 0.461 0.138 0.415 0.553 1.291 0.369 0.138 0.553 0.507 0.046 0.231 1.153 0.692 0.369 0.415 7.423 0.553 0.645 0.692 0.415 0.415 0.323 0.138 0.000 0.046 0.046 0.000 0.092 0.599 0.553 0.599 0.784
5. 901 0.461 0.599 0.138 0.046 0.092 0.138 0.092 0.000 0.046 0.000 0.000 0.138 0.553 1.429 1.199 0.692 5.625 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 1.429 0.876 0.000 2.444 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.369 0.046 0.000 0.415 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.199 2.029 1.060
1. 107 1.291 2.766
1. 982 1.153 2.444 2.075 0.968 1.107 3.366 4.657 3.181 1.890 0.415 10.051 0.000 32.273 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS-HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2169 700 700 2169 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

5.99 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2009/08/06 E2-14

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.046 0.046 0.138 0.277 0.277 0.184 0.277 0.277 0.369 0.461 0.231 0.184 0.138 0.046 0.000 0.046 0.092 0.553 0.599 0.507 1.798 2.720 0.738 0.922 1.475 1.245 0.830 1.291 1.521 0.184 0.184 0.231 0.507 0.369 0.231 0.692 0.507 1.199 0.000 0.000 0.369 0.369 0.000 0.138 1.107 0.138 0.138 0.369 6.132 0.138 0.231 0.138 0.231 0.046 0.092 0.046 0.000 0.000 0.046 0.000 0.000 0.231 0.184 0.046 0.000 1.429 0.000 0.184

0. 184 0.000 0.046 0.092 0.000 0.000 0.000 0.092 0.000
0. 000 0.138 0.092 0.092 0.046 0.968 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.784 1.383 1.291 1.706 2.674 4.288 1.060 1.199 2.213 2.213 1.060
1. 614
3. 135 0.645 0.461
0. 692

>=24.5 TOTAL SUBTOTAL 2.997 14.892 0.000 26.418 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2169 573 573 2169 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

3.14 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2009/08/06 E2-15

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.092 0.184 0.138 0.461 0.369 0.415 0.184 0.323 0.138 0.138 0.000 0.000 0.046 0.046 0.046 0.138 2.720

0. 692 0.184 0.461 0.323 1.245 1.107 0.323 0.277 0.231 0.461 0.277
0. 000 0.000 0.138 0.092 0.645 6.455 0.830 0.830 0.231 0.184 0.323 0.092 0.092 0.000 0.092 0.092 0.000 0.000 0.000 0.000 0.000 0.092 2.858 0.000 0.092 0.231 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.323 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
1. 614 1.291 1.060
0. 968 1.936 1.614 0.599 0.599 0.461 0.692 0.277 0.000 0.046 0.184 0.138 0.876 0.000 12.356 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2169 268 268 2169 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/08/06 MEAN WIND SPEED =

2.58 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-16

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/10D M)

Browns Ferry Nuclear Plant STA 52 D -

Validated Edited Data APR 1, 2009 -

JUN 30, 20D9 WIND DIRECTION N

NNE NE ENE E

E SE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.013 0.005 0.004 0.005 0.003 0.002 0.002 0.002 0.002 0.000 0.001

0. 000 0.000 0.000 0.001 0.004 0.046
0. 692 0.092 0.138 0.369 0.231 0.231 0.184 0.277 0.092 0.046 0.092 0.000 0.046 0.046 0.138 0.369 3.043 0.830 0.461 0.277 0.277 0.138 0.046 0.092 0.000 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.138 2.397 0.323 0.092 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.507 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.857 0.650 0.418 0.743 0.372 0.279 0.279 0.279 0.232 0.046
0. 093 0.000 0.046 0.046 0.139 0.511 5.994 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2169 130 130 2169 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA 52 D -

Validated STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

1.78 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Edited Data DATE PRINTED: 2009/08/06 E2-17

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 12 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER E2-18

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.045 0.045 0.227 0.409 0.409 0.318 0.045 0.091 0.000 0.000 0.000 0.000 1.636 0.000 0.000 0.045 0.000 0.045 0.273 0.727 0.454 0.227 0.318 0.045 0.091 0.000 0.000 0.000 0.000 2.226 0.182 0.136 0.000 0.000 0.045 0.227 0.045 0.000 0.000 0.045 0.000 0.045 0.182 0.136 0.000 0.045 1.090 0.227 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000o 0.000 0.091 0.318

0. 682 0.500 1.908 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.273 0.227 0.000 0.500 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.409 0.273 0.045 0.000 0.136 0.545 1.000
0. 863 0.636
0. 682 0.091 0.227 0.273 0.727
0. 909 0.545 7.360 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 162 162 2201 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/11/06 MEAN WIND SPEED =

6-33 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-19

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 20D9 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.227 0.273

0. 363 0.136 0.045 0.000 0.000 0.000 0.000 1.090 0.091 0.000 0.045 0.000 0.000 0.273 0.591 0.091 0.045 0.091 0.091 0.409 0.318 0.091 0.045 0.136 2.317 0.182 0.227 0.091 0.000 0.091 0.273 0.000 0.000 0.000 0.000 0.000 0.136 0.182 0.136 0.182 0.318 1.817 0.136
0. 000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.045 0.500 0.727
0. 136 1.590 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.0 00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.409 0.227 0.227 0.000 0.091 0.545 0.591 0.318 0.318 0.454 0.227 0.591 0.545 0.727
0. 954 0.591 6.815 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 150 150 2201 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/11/06 MEAN WIND SPEED =

5.83 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-20

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY. CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

->=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.04-5 0.091 0.136 0.409 0.545

0. 636 0.454 0.409 0.318 0.136 0.000 0.000 0.000 3.180 0.318 0.182 0.000 0.045 0.091 0.273 0.273 0.136 0.091 0.182 0.045 0.318 0.182 0.136 0.182 0.136 2.590 0.409 0.045 0.000 0.000 0.045 0.273 0.000 0.000 0.000 0.045 0.000 0.000 0.091 0.136 0.045 0.227 1.318 0.091 0.000 0.045 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.182 0.454 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.045 0.000 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.818 0.227 0.045 0.091 0.227 0.727
0. 682
0. 682 0.727
0. 682 0.454
0. 636 0.409 0.454 0.318 0.545 7.724 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 170 170 2201 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/11/06 MEAN WIND SPEED =

4.59 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-21

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.045 0.000 0.000 0.136 0.045 0.045 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.227 0.409 0.273 0.636 0.682 1.863

1. 636 1.545 1.636 3.180 1.454 1.408 0.227 0.227 0.227 0.136 0.909 0.818 0.591 0.636 2.317 3.362 0.409 0.273 0.182 0.818 0.136 0.772 0.909 0.363 0.273 0.727 0.318 0.818 0.227 0.182 0.136 1.090 0.000 0.000 0.000 0.136 0.000 0.318 0.727 0.182 0.227 0.227 4.589 0.045 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.227 0.500 0.454 0.136 1.545 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.499 2.135 1.181 1.499 3.135 6.315 2.181 1.863 1.863 4.225 1.590 2.544 2.090 1.318 1.181 1.227 0.363 15.766 13.494 0.000 35.847 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 789 789 2201 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/11/06 MEAN WIND SPEED =

3.99 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-22

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.091 0.136 0.273 0.227 0.045 0.045 0.363 0.273 0.182 0.136 0.227 0.000 0.045 0.000 2.181 1.136 1.227 0.727 1.272 1.908 1.181 0.409 0.545 1.272 0.591 0.545 0.682 0.182 0.227 0.318 1.181 13.403 0.500 0.500 0.318 0.772 2.090 0.772 0.045 0.000 0.000 0.091 0.000 0.000 0.227 0.091 0.409 0.863 6.679 0.091 0.136 0.363 0.000 0.091 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.227 0.182 1.181 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.182 0.363 0.091 0.636 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.726 1.999 1.499 2.181 4.362 2.226 0.500 0.591 1.636

0. 954 0.727 0.818
0. 682 0.500 1.408 2.317 0.000 24.125 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 531 531 2201 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/11/06 MEAN WIND SPEED =

3.20 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-23

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.091 0.045 0.182 0.318 0.136 0.000 0.091 0.000 0.000 0.045 0.000 0.045 0.000 0.091 0.000 0.136 1.181 2.135 1.272 0.363

0. 954 1.136 0.318 0.000 0.000 0.091 0.045 0.000 0.000 0.000 0.045 0.045
0. 682 7.088 0.727 0.682 0.000 0.318
0. 636
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.273
2. 635 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.227 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
2. 953 2.045
0. 636 1.590
1. 908 0.318 0.091 0.000 0.091 0.091 0.000 0.045 0.000 0.136 0.045 1.181 SUBTOTAL 0.000 11.131 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 245 245 2201 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/11/06 MEAN WIND SPEED =

2.86 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-24

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.818 0.409 0.545 0.091 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.591 2.544 1.726 1.136 0.500 0.409 0.182 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.182 4.180 0.136 0.045 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.273 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.681 1.590 1.090 0.545 0.227 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.772 6.997 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 154 154 2201 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2009/11/06 MEAN WIND SPEED =

1.91 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-25

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 13 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E2-26

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

E SE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.412 0.321 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.825 0.000 0.000 0.000 0.000 0.000 0.046 0.183 0.183 0.137 0.275 0.092 0.046 0.000 0.000 0.000 0.000
0. 962 0.046 0.000 0.046 0.046 0.046 0.046 0.000 0.000 0.000 0.000 0.137 0.046 0.092 0.000 0.000 0.000 0.504 0.321 0.183 0.137 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.137 0.046 0.092 0.046 1.283 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.046 0.275 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.367' 0.275 0.183 0.092 0.092
0. 092 0.183 0.596
0. 458
0. 321 0.275 0.321 0.275 0.092 0.137 0.092 3.850 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 84 84 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2010/02/22 MEAN WIND SPEED =

6.61 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-27

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.092 0.000 0.275 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.550 0.000 0.000 0.000 0.000

.0.000 0.183 0.367 0.092 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.779 0.229 0.229

0. 092 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.137 0.000 0.046
0. 092
0. 962 0.275 0.137
0. 092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.229 0.183 0.183 0.046
1. 192 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092
0. 137 0.092 0.137 0.458 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.504 0.367 0.183 0.092 0.092 0.183 0.458 0.092
0. 367
0. 000
0. 092
0. 137 0.458
0. 321 0.321 0.275 3.941 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 86 86 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2010/02/22 MEAN WIND SPEED =

7.09 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-28

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW Nw NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.275 0.183 0.275 0.137 0.046 0.046 0.000 0.000 0.000 0.000 0.962 0.000 0.046 0.046 0.000 0.046 0.092 0.321 0.092 0.000

0. 000
0. 092 0.000 0.046 0.046 0.046 0.000 0.871 0.321 0.229
0. 092 0.046 0.046 0.092 0.046 0.000 0.000 0.000 0.046 0.092 0.229 0.275 0.092 0.137 1.742 0.000 0.137 0.137 0.000 0.000 0.046 0.000 0.00.0 0.000 0.000 0.000 0.046 0.183 0.367 0.321 0.137 1.375 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.046
0. 137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.321 0.412 0.275 0.046 0.092 0.229
0. 642 0.275 0.275 0.137 0.183 0.183 0.504 0.733 0.458 0.321 5.087 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 111 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2010/02/22 MEAN WIND SPEED =

6.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-29

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1-5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.137 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.137 0.046 0.321 0.412 0.779 0.825 1.329 1.467 2.016 1.604 0.733 0.687 0.779 0.137 0.137 0.229 1.008 0.779 0.550

0. 642 1.558 1.192 1.375 0.275 0.458 0.458 0.183 0.779 1.421 0.412 0.137 0.275 11.503 1.054 0.687 0.275 0.458 0.550 0.917 0.092 0.000 0.092 0.137 0.092 0.183 0.917 0.504
0. 687 1.054 7.699 0.733 0.321 0.229 0.137 0.046 0.367 0.229 0.000 0.000 0.000 0.183 0.183
0. 687 0.596 1.421 2.704 7.837 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.825 0.917 0.046 1.879 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.933 1.833 1.375 1.650 2.933 3.346 3.071 1.787 2.704 2.246 1.192 1.925 3.850 2.475 3.300 4.308 40.926 0.367 11.641 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 893 893 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2010/02/22 MEAN WIND SPEED =

5.56 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-30

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.046 0.046 0.046 0.183 0.275 0.092 0.321 0.000 0.137 0.092 0.000 0.092 0.046 0.000 0.687 0.321 0.183

0. 642 1.558 1.237 0.871
0. 917 1.971 1.146 0.367 0.321
0. 642 0.137 0.412 0.367
0. 458 0.275
0. 458 0.412 1.192 2.062 0.871 0.321 0.504 0.412
0. 092 0.137 0.642 0.000 0.046 0.642 8.524 0.183 0.092 0.046 0.046 0.046 0.275 0.412 0.000 0.092 0.046 0.046 0.183 0.137 0.092 0.275 0.412 2.383 0.000 0.137 0.000 0.000 0.000 0.092 0.321 0.000 0.000 0.046 0.000 0.000
0. 137 0.092 0.183 0.046 1.054 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.421 0.825 0.733 1.146 2.841
3. 987 2.750 1.329 2.887
1. 650 0.642 0.733 1.558 0.412
0. 962
1. 467 SUBTOTAL 1.467 11.778 0.000

.0.000 25.344 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 553 553 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2010/02/22 MEAN WIND 'SPEED =

3.73 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-31

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.183 0.092 0.092 0.137 0.137 0.183 0.412 0.137 0.092 0.000 0.000 0.046 0.000 0.046 0.137 1.833 1.054 0.687 0.183 0.321 0.917 0.917 0.871 0.183 0.412 0.137 0.092 0.046 0.046 0.092 0.183 0.504 6.645 0.917 0.229 0.092 0.504 0.229 0.183 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.137 2.383 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0-.000 0.000 0.000 0.000 2.291 1.100 0.367 0.917 1.283 1.237 1.054 0.642 0.596 0.229 0.137 0.046 0.092 0.092 0.229 0.779 0.000 11.091 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 2182 242 242 2182 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

2.70 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/02/22 E2-32

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 917 0.779 0.596 0.275 0.183 0.137 0.046 0.275 0.046 0.000 0.046
0. 000 0.000 0.046 0.275
0. 642 4.262 0.917 0.779
0. 917 0.825 0.367 0.046 0.046 0.046
0. 137 0.046
0. 000 0.000 0.046 0.000 0.046 0.871 5.087 0.183 0'.046 0.000 0.137 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.412 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.016
1. 604 1.512 1.237 0.596 0.183 0.092 0.321 0.183 0.046 0.046 0.000 0.046 0.046 0.321 1.512 9.762 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 213 213 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA--T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

1.73 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/02/22 E2-33

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 14 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FIRST QUARTER E2-34

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A WDELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.032 0.010 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.001 0.034 0.065 0.147 0.025 0.015 0.009 0.000 0.000 0.000 0.000 0.297 0.007 0.002 0.000 0.000 0.000 0.000 0.055 0.000 0.076 0.018

0. 000 0.007 0.000 0.000 0.004 0.000 0.170 0.138 0.057 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.008 0.024 0.038 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.046 0.047 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.198 0.237

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.145 0.059 0.008 0.000 0.000 0.001 0.093 0.097 0.234 0.047 0.015 0.016 0.008 0.017 0.113 0.283 1.136 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2145.000 344.080 33.170 24.370 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-35

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.008 0.010 0.000 0.003 0.000 0.000 0.001 0.000 0.074 0.002 0.002 0.008 0.000 0.000 0.004 0.000 0.000 0.100 0.000 0.000 0.000 0.005 0.004 0.006 0.000 0.132 0.039 0.023 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.044 0.049 0.055 0.025 0.269 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.106 0.039 0.009 0.154 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.090 0.000 0.133

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.042 0.025 0.024 0.000 0.000 0.005 0.000 0.052 0.114 0.010 0.000 0.021 0.049 0.202 0.191 0.034 0.770 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS B GROUND LEVEL STABILITY CLASS B 2145.000 344.080 22.670 16.510 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-36

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.075 0.085 0.014 0.029 0.008 0.000 0.000 0.001 0.000 0.000 0.212 0.013 0.012 0.005 0.000 0.002 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.005 0.020 0.003 0.004 0.105 0.069 0.042 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.009 0.037 0.053 0.035 0.276 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.000 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=2 4. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.097 0.054 0.016 0.000 0.002 0.000 0.086 0.091 0.014 0.070 0.008 0.019 0.014 0.058 0.075 0.039 0.644 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2145.000 344.080 56.550 13.820 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-37

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.055 0.090 0.021 0.003 0.006 0.001 0.004 0.000 0.000 0.000 0.188 0.017 0.022 0.006 0.002 0.024 0.077 0.147 0.179 0.276 0.065 0.020 0.006 0.019 0.007 0.010 0.008 0.886 0.073 0.059 0.057 0.021 0.000 0.008 0.027 0.000 0.264 0.041 0.031 0.016 0.018 0.023 0..062 0.033 0.733 0.196 0.254 0.075 0.000 0.000 0.041 0.092 0.000 0.065 0.025 0.000 0.068 0.205 0.112 0.381 0.388 1.902 0.000 0.039 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.169 0.139 0.081 0.329 0.391 1.166 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.072 0.000 0.072

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.286 0.374 0.157 0.024 0.024 0.135 0.321 0.269

0. 627 0.134 0.057 0.259 0.384 0.222 0.855 0.820 4.947 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2145.000 344.080 1108.500 106.110 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45-30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-38

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.003 0.000

0. 000
0. 022
0. 001
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.024 0.024 0.007 0.006 0.029 0.041 0.142 0.282 0.183 0.046 0.015 0.033 0.015 0.005 0.004 0.006 0.860
0. 067 0.093 0.021 0.032 0.032 0.137 0.276 0.044 0.526 0.109 0.014 0.006 0.048 0.008 0.005 0.091 1.510 0.047 0.085 0.046 0.035 0.000 0.000 0.000 0.000 0.862 0.141 0.009 0.007 0.016 0.005 0.031 0.102 1.388 0.027 0.016 0.020 0.008 0.000 0.000 0.019 0.000 0.303 0.079 0.000 0.040 0.080 0.009 0.043 0.157 0.800 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.010 0.010 0.016 0.068 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.165 0.220 0.094 0.081 0.063 0.178

0. 437 0.347 1.875 0.374 0.039 0.118 0.160 0.036 0.093 0.372 4.653 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2145.000 344.080 741.670 99.810 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-39

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.015 0.002 0.040 0.049 0.013

0. 000 0.000 0.000 0.000 0.004 0.000 0.000 0.124 0.030 0.029 0.002 0.018 0.044 0.048 0.067 0.262
0. 152 0.037 0.007 0.000 0.000 0.000 0.000 0.010 0.707 0.043 0.070 0.046 0.019 0.038 0.015 0.008 0.035 0.385 0.032 0.000 0.000 0.000 0.000 0.002 0.073 0.765 0.000 0.069 0.000 0.000 0.000 0.000 0.000 0.000 0.486 0.019 0.000 0.000 0.000 0.000 0.000 0.008 0.582 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0..398 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.398 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.075 0.168 0.048 0.037 0.097 0.065 0.114 0.346 1.434 0.088 0.007 0.000 0.000 0.004 0.002 0.091 2.577 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F

2145.000 344.080 124.410 55.270 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-40

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.039 0.043 0.061 0.106 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.256 0.022 0.004 0.000 0.009 0.004 0.009 0.065 0.269 0.221 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.608 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.320 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.353 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.040 0.004 0.000 0.016 0.043 0.053 0.126

0. 392
0. 637 0.000 0.000 0.000 0.000 0.000 0.000 0.004 1.314 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2145.000 344.080 58.030 28.190 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-41

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 15 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

SECOND QUARTER E2-42

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH-)

0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.036 0.058 0.065 0.111 0.052 0.000 0.010 0.000 0.000 0.000 0.000 0.349 0.000 0.000 0.000 0.000 0.000 0.082 0.104 0.033 0.050 0.044 0.006 0.016 0.009 0.000 0.000 0.000 0.343 0.000 0.000 0.000 0.000 0.000 0.083 0.060 0.000 0.000 0.000 0.000 0.000 0.015 0.005 0.000 0.005 0.168 0.007 0.015 0.025 0.000 0.000 0.000 0.027 0.00 0 0.000 0.000 0.000 0.026 0.055 0.108 0.064 0.030 0.357 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.144 0.000 0.000 0.191 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.000 0.000 0.036

>=24..5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.007 0.015 0.025 0.000 0.016 0.201 0.297 0.098

0. 162 0.095 0.006 0.052 0.080 0.292 0.064 0.035 1.444 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2110.000 233. 920
30. 470
30. 470 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-43

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.014 0.005 0.035 0.002 0.003 0.000 0.000 0.000 0.000 0.000 0.079 0.000 0.000 0.000 0.000 0.000 0.011 0.026 0.006 0.000 0.018 0.000 0.012 0.015 0.000 0.000 0.000 0.087 0.005 0.000 0.003 0.000 0.009 0.033 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.016 0.016 0.009 0.109 0.026 0.017 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.006 0.079 0.096 0.030 0.308 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.035 0.000 0.079 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.031 0.017 0.049 0.000 0.009 0.064 0.040 0.011

0. 035 0.019 0.003 0.021 0.040 0.140 0.146 0.038 0.663 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2110.000 233.920 13.990 13.990 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-44

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

'0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.010 0.009 0.033 0.008 0.011 0.002 0.000 0.000 0.000 0.000 0.082 0.000 0.004 0.000 0.000 0.005 0.012 0.010 0.000 0.000 0.009 0.000 0.015 0.013 0.003 0.000 0.000 0.071 0.010 0.007 0.000 0.000 0.000

0. 023 0.030 0.000 0.000 0.000 0.000 0.014 0.012 0.014 0.021 0.006 0.137 0.007 0.024 0.005 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.074 0.102 0.014 0.252 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.028 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.034 0.000 0.067

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.017 0.035 0.005 0.000 0.013 0.043

0. 051 0.009 0.033 0.017 0.011 0.031 0.043 0.133 0.185 0.020 0.646 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS C GROUND LEVEL STABILITY CLASS C 2110.000 233.920 13.960 13.640 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-45

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2009 -

JUN 30, 2009

.WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.001 0.001 0.000 0.000 0.007 0.064 0.113 0.032 0.120 0.097 0.041 0.010 0.027 0.001 0.000 0.000 0.514 0.008 0.018 0.000 0.025 0.013 0.227 0.036 0.009 0.100 0.092 0.008 0.019 0.072 0.014 0.007 0.018 0.665 0.074 0.067 0.064 0.034 0.059 0.070 0.027 0.000 0.020 0.009 0.000 0.016 0.080 0.055 0.053 0.091 0.719 0.082 0.108 0.021 0.005 0.016 0.111 0.052 0.000 0.046 0.000 0.000 0.035 0.091 0.245 0.192 0.114 1.118 0.000 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.575 0.251 0.000 0.886 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.318 0.047 0.000 0.365

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.164 0.212 0.086 0.064 0.095 0.475 0.228 0.040 0.286 0.198 0.049 0.080 0.312 1.209 0.550 0.223 4.270 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS D GROUND LEVEL STABILITY CLASS D 2110.000 233.920 968.460 90.090 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-46

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.000 0.010 0.005 0.010 0.011

0. 022 0.001 0.000 0.000 0.000 0.000 0.000 0.074 0.000 0.011 0.020 0.012 0.142 0.235 0.055 0.098 0.173 0.145 0.017 0.037 0.023 0.003 0.002 0.005 0.978 0.064 0.043 0.019 0.076 0.055 0.253 0.000 0.000 0.092 0.078 0.000 0.009
0. 109 0.007 0.016 0.040 0.861 0.025 0.033 0.022 0.035 0.008 0.027 0.045 0.000 0.000 0.022 0.000 0.000 0.034 0.023 0.007 0.000 0.280 0.000 0.034 0.033 0.000 0.009 0.073 0.000 0.000 0.000 0.095 0.000 0.000 0.025 0.017 0.018 0.009 0.313 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.089

0. 122 0.093 0.136 0.214 0.598 0.104 0.108 0.277 0.361 0.018 0.046 0.191 0.050 0.043 0.054 2.505 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2110.000 233.920 833.580 52.860 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-47

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECT ION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.009 0.012 0.009 0.015 0.006 0.024 0.004 0.009 0.000 0.000 0.000 0.000 0.009 0.000 0.110 0.048 0.006 0.018 0.025 0.097 0.099 0.032 0.022 0.045 0.067 0.005 0.000

0. 000
0. 008
0. 003 0.031 0.505 0.116 0.130 0.033 0.027 0.048 0.015 0.014 0.000 0.026 0.012 0.000 0.000 0.000 0.000 0.000 0.010 0.431 0.000 0.016 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.054 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24..5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL

0. 164 0.165 0.098
0. 064 0.154 0.129 0.051 0.046 0.075 0.089 0.005 0.000 0.000 0.008 0.013 0.041 1.100 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2110.000 233. 920 208.010 23.200 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-48

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.001 0.000 0.000 0.001 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.006 0.000 0.004 0.027 0.026 0.030 0.026 0.032 0.009 0.007 0.000 0.000 0.000 0.007 0.000 0.009 0.183 0.067 0.031 0.019 0.020 0.009 0.006 0.008 0.000 0.026 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.187 0.053 0.016 0.000 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.083 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

  • 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.127 0.048 0.024 0.061 0.035 0.037 0.035 0.033 0.035 0.007 0.000 0.000 0.000 0.007 0.000 0.010 0.458 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2110.000 233.920 41.530 9.670 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-49

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 16 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

THIRD QUARTER E2-50

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.008 0.030 0.016 0.022 0.028 0.000 0.006 0.000 0.000 0.000 0.000 0.112 0.000 0.000 0.000 0.000 0.004 0.038 0.063 0.021 0.026 0.037 0.008 0.008 0.000 0.000 0.000 0.000 0.205 0.017 0.012 0.000 0.000 0.007 0.037 0.007 0.000

.0. 000 0.021 0.000 0.006 0.016 0.013 0.000 0.004 0.142 0.035 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.053 0.110 0.076 0.296 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.055 0.045 0.000 0.100 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.052 0.023 0.000 0.000 0.014 0.083 0.100 0.036 0.047 0.087 0.008 0.020 0.027

0. 122 0.155 0.080 0.855 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2192.000 166.000 19.650 18.740 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-51

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.002 0.016 0.010 0.000 0.000 0.000 0.000 0.000 0.031 0.002 0.000 0.000 0.000 0.000 0.031 0.049 0.002 0.013 0.000 0.000 0.024 0.017 0.003 0.000 0.000 0.142 0.015 0.019 0.009 0.000 0.009 0.042 0.000 0.000 0.000 0.000 0.000 0.017 0.021 0.010 0.016 0.025 0.183 0.022 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.078 0.099 0.021 0.234 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.040 0.019 0.015 0.000 0.0 09 0.073 0.049 0.006 0.015 0.016 0.010 0.041 0.045 0.091 0.116 0.046 0.589 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2192.000 166.000 14.830 12.920 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-52

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.015 0.014 0.011 0.028 0.026 0.005 0.003 0.000 0.000 0.000 0.000 0.110 0.004 0.001 0.000 0.000 0.009 0.032 0.016 0.000 0.007 0.008 0.000 0.009 0.007 0.000 0.001 0.005 0.099 0.038 0.002 0.000 0.000 0.005 0.042 0.000 0.000 0.000 0.015 0.000 0.000 0.012 0.015 0.002 0.021 0.151 0.014 0.000 0.007 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.009 0.028 0.075 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.010 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.056 0.003 0.007 0.000 0.021 0.099 0.030 0.011 0.035 0.049 0.005 0.012 0.019 0.051 0.022 0.053 0.473 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2192.000 166.000 39.390 10.370 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-53

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.001 0.000 0.002 0.014 0.123 0.044 0.071 0.086 0.180 0.043 0.007 0.000 0.000 0.000 0.002 0.573 0.036 0.023 0.013 0.024 0.208 0.424 0.024 0.009 0.052 0.167 0.019 0.053 0.046 0.006 0.012 0.030 1.146 0.037 0.072 0.020 0.021 0.019 0.180 0.000 0.000 0.000 0.046 0.000 0.060 0.087 0.019 0.021 0.032 0.614 0.008 0.008 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.000 0.000 0.036 0.085 0.074 0.021 0.279 0.000 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.029 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.081

0. 124 0.045 0.047 0.240 0.727 0.069 0.080 0.138 0.427 0.062 0.120 0.169 0.120 0.108 0.086 2.641 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2192.000 166.000 1167.380 57.900 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-54

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.010 0.001 0.010 0.000 0.000 0.010 0.016 0.004 0.000 0.000 0.000 0.000 0.000 0.058 0.046 0.026 0.013 0.061 0.132 0.073 0.026 0.042

0. 121 0.075 0.013 0.012 0.003 0.002 0.010 0.060 0.714 0.055 0.055 0.027 0.068 0.246 0.105 0.004 0.000 0.000 0.019 0.000 0.000 0.025 0.008 0.034 0.100 0.746 0.013 0.021 0.050 0.000 0.016 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.027
0. 027 0.170 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.062 0.016 0.111 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026 0.000 0.026 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.114 0.108 0.090 0.138 0.396 0.196 0.030 0.042 0.131 0.110 0.017 0.012 0.035 0.042 0.159 0.203 1.824 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS E GROUND LEVEL STABILITY CLASS E 2192.000 166.000 755.230 39.980 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-55

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 IWIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.003 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.194 0.104 0.017 0.042 0.077 0.013 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.496 0.108 0.106 0.000 0.037 0.063 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.352 0.000 0.008 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.036 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.302 0.218 0.044 0.082 0.142 0.013 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.902 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2192.000 166.000 178.370 19.770 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-56

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003

0. 000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.008 0.146 0.056 0.015 0.010 0.011 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.249 0.021 0.004 0.005 0.002 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.169 0.060

0. 021 0.013 0.012 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.288 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2192.000 166.000
17. 150 6.320 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-57

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 17 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FOURTH QUARTER E2-58

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 "0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.048 0.023 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.071 0.000 0.000 0.000 0.000 0.000 0.005 0.020 0.015 0.012 0.029 0.015 0.006 0.000 0.000 0.000 0.000 0.103 0.005 0.000 0.006 0.005 0.005 0.005 0.000 0.000 0.000 0.000 0.024 0.004 0.009 0.000 0.000 0.000 0.063 0.060 0.032 0.025 0.008 0.009 0.000 0.000 0.000 0.000 0,000 0.000 0.043 0.020 0.006 0.015 0.009 0.227 0.000 0.031 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.009 0.009 0.010 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.065 0.063 0.031 0.013 0.014 0.011 0.020 0.063 0.036 0.029 0.038 0.053 0.046 0.016 0.024 0.018 0.539 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2182.000 262.000 11.770 11.770 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-59

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M) kJ BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.003 0.000 0.024 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.027 0.000 0.000 0.000 0.000 0.000 0.026 0.017 0.004 0.015 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.066 0.024 0.023 0.009 0.007 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.019 0.000 0.003 0.008 0.107 0.049 0.021 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.033 0.023 0.024 0.006 0.178 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.059 0.028 0.018 0.044 0.149 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.073 0.044 0.022 0.007 0.006 0.026 0.020 0.004 0.039 0.000 0.010
0. 012 0.110 0.051 0.045
0. 058 0.528 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2182.000 262.000 15.390 11.520 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-60

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000" 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.008 0.001 0.006 0.003 0.000 0.000 0.000 0.000 0.000 0.026 0.000 0.000 0.000 0.000 0.006 0.003 0.019 0.001 0.000 0.000 0.007 0.000 0.004 0.000 0.000 0.000 0.039 0.038 0.019 0.008 0.005 0.007 0.017 0.028 0.000 0.000 0.000 0.007 0.012 0.026 0.020 0.004 0.014 0.206 0.000 0.022 0.019 0.000 0.000 0.024 0.000 0.000 0.000 0.000 0.000 0.008 0.030 0.050 0.047 0.023 0.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.009 0.000 0.012 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.038 0.041 0.027 0.005 0.013 0.044 0.054 0.009 0.001 0.006 0.017 0.020 0.092 0.079 0.051 0.049 0.549 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2182.000 262.000 18.070 11.980 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-61

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002
0. 002 0.000 0.000 0.001 0.027 0.043 0.076 0.092
0. 197 0.148 0.015 0.008 0.000 0.000 0.002 0.000
0. 611 0.074 0.038 0.016 0.029 0.114 0.137 0.186 0.042 0.093 0.081 0.011 0.054 0.066 0.012 0.001 0.022
0. 975 0.140 0.078 0.028 0.056 0.073 0.187 0.080 0.000 0.017 0.044 0.018 0.026 0.114 0.043 0.071 0.138 1.115 0.137 0.067
0. 037 0.021 0.009 0.138 0.178 0.000 0.000 0.000 0.045 0.034 0.113 0.090 0.234 0.454
1. 558 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.009 0.188 0.199 0.010 0.442 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.353 0.183 0.082

0. 108 0.222
0. 505 0.519 0.134 0.309 0.274 0.089 0.158 0.303 0.334 0.508
0. 623 4.704 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2182.000 262.000 1023.200 102.650 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-62

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.005 0.005 0.001 0.013 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.029 0.035 0.016 0.008 0.040 0.095 0.120 0.123 0.122 0.223 0.096 0.011 0.009 0.022 0.000 0.011 0.016 0.948 0.053 0.029 0.049 0.043 0.147

0. 624 0.394 0.137 0.170 0.076 0.008 0.014 0.056 0.000 0.005 0.074 1.877 0.029 0.016 0.007 0.006 0.007 0.082 0.299 0.000 0.034 0.011 0.009 0.032 0.018 0.012 0.034 0.063 0.659 0.000 0.027 0.000 0.000 0.000 0.067 0.282 0.000 0.000 0.026 0.000 0.000 0.064 0.016 0.034 0.008 0.523 0.000 0.000 0.000 0.000 0.000 0.135 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.135 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.118 0.088 0.064 0.089 0.253 1.034 1.103 0.260 0.439 0.209 0.029 0.054 0.160 0.028 0.083 0.161 4.172 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2182.000 262.000 796.670 91.040 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-63

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.004 0.004 0.010 0.008 0.011 0.030 0.006 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.081 0.087 0.050 0.008 0.019 0.076 0.097 0.115 0.014 0.070 0.024 0.003 0.005 0.002 0.005 0.003 0.050 0.631 0.140 0.034 0.011 0.058 0.033 0.068 0.000 0.000 0.034 0.000 0.002 0.000 0.000 0.000 0.000 0.021 0.403 0.036 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.082 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.264 0.086 0.023 0.081 0.119 0.174 0.126 0.090 0.111 0.030 0.005 0.005 0.002 0.005 0.003 0.071 1.196 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2182.000 262.000 252.950 26.100 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-64

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.008 0.006 0.010 0.008 0.009 0.000 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.065 0.063 0.047 0.025 0.019 0.011 0.001 0.000 0.001 0.020 0.000 0.000 0.000 0.000 0.000 0.001 0.013 0.203 0.024 0.008 0.000 0.014 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.093 0.063 0.031 0.043 0.025 0.010 0.000 0.016 0.020 0.000 0.000 0.000 0.000 0.000 0.001 0.015 0.318 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2182.000 262.000 63.950 6.940 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-65

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 18 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FIRST QUARTER E2-66

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.115 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.076 0.074 0.038 0.000 0.304 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.035 0.000 0.000 0.060 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.115 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.101 0.110 0.038 0.000 0.410 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2145.000 1800.920 33.170 8.800 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-67

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.082 0.039 0.000 0.000 0.000 0.000 0.000 0,.000 0.000 0.000 0.000 0.000 0.000 0.075 0.000 0.000 0.037 0.151 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000

>=2 4. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.007 TOTAL 0.078 0.000 0.000 0.000 0.000 0.00 0 0.047 0.000 0.000 0.000 0.000 0.000

0. 125 0.000 0.000 0.037 0.287 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF ELEVATED RELEASES TOTAL HOURS OF STABILITY CLASS B TOTAL HOURS OF ELEVATED STABILITY CLASS B 2145. 000 1800. 920
22. 670 6.160 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-68

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

E SE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4.

3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.047 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.090 0.045 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.088 0.000 0.000 0.000 0.310 0.000 0.042 0.000 0.000 0.000 0.084 0.040 0.000 0.000 0.042 0.083 0.039 0.042 0.079 0.000 0.039 0.490 0.231 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.114 0.111 0.076 0.076 0.223 0.832 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.019 0.000 0.037 0.073

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.003 0.000 0.007 TOTAL 0.368 0.087 0.043 0.000 0.000 0.084 0.133 0.000 0.093 0.133 0.083 0.153 0.258 0.178 0.079 0.299

1. 992 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2145. 000 1800. 920
56. 550
42. 730 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-69

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000
0. 000 0.186 0.000 0.000
0. 093 0.280 0.280 0.280 0.420 0.233 0.140 0.140 0.093 0.186 0.047 2.378 0.280
0. 606 0.606 0.186 0.186 0.233 0.513 0.466 0.326 0.233 0.466 0.233 0.326 0.233 0.420 0.186 5.501 0.406 0.982 0.588 0.090 0.228 0.229 0.316 0.543
0. 675 0.320 0.133 0.537 0.404 0.579 0.405 0.359 1.536 1.788 0.326 0.085 0.042 0.125 0.732 1.357 1.768 1.006 0.732 0.331 0.624 1.110 1.867 1.578 1.662 1.097 0.228 0.000 0.000 0.000 0.493 1.324 1.665 1.060 0.615 0.452 0.566 0.686 2.243 1.855 0.207 0.103 0.000 0.000 0.000 0.000 0.056 0.434 0.712 0.334 0.000 0.183 0.092 0.031 0.332 0.398 2.882

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.025 0.069 0.000 0.007 0.018 0.000 0.000 0.029 0.023 TOTAL 4.090 4.576 1.936 0.361 0.456 0.681 2.443 4.429 5.495 3.372 2.186 1.893 2.152 2.732 5.482 4.446 SUBTOTAL 6.792 15.008 13.948 0.177 46.731 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2145.000 1800.920 1108.500 1002.390 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-70

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<=~ 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.140 0.047 0.093 0.047 0.000 0.047 0.186 0.280 0.047 0.140 0.280 0.093 0.047 0.047 0.093

1. 632 0.140 0.000 0.093 0.093 0.186 0.047 0.186 0.280 0.140 0.420 0.280 0.280 0.326 0.140 0.000 0.140 2.751 0.449 0.356 0.314 0.090 0.400 0.443 0.223 0.586
0. 625 0.226 0.271 0.182 0.090 0.046 0.089 0.090 4.480 0.734 0.897 0.731 0.247 0.373 1.761 1.334 1.912 2.194 0.847 0.328 0.253 0.125 0.124 0.165 0.813 12.837 0.153
0. 152 0.039 0.038 0.000 0.115 1.221 1.408 1.741 0.756 0.263 0.075 0.038 0.112 0.189 0.229 6.529 0.000 0.000 0.000 0.000 0.000 0.000 0.210 0.510 0.499 0.083 0.085
0. 022 0.040 0.000 0.037 0.076
1. 562

>=24.

.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.071 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.523 1.546 1.223 0.562 1.054 2.365 3.221 4.954 5.494 2.377 1.366 1.091 0.712 0.469 0.526 1.441 0.087 29.924 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2145.000 1800.920 741.670 641.860 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-71

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2009 -

MAR 31, 20D9 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.047 0.000 0.047 0.186 0.140 0.000 0.000 0.047

0. 000 0.000 0.047 0.047 0.000 0.559 0.000 0.000 0.045 0.181 0.131 0.045 0.175 0.090 0.000 0.090 0.046 0.000 0.000 0.000 0.046 0.000 0.851 0.082 0.039 0.082 0.286 0.120 0.206 0.419 0.000 0.081 0.000 0.000 0.000 0.000 0.000 0.000
0. 123 1.436 0.000 0.114 0.000 0.039 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24..5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.082 0.153 0.126 0.552 0.252 0.344 0.780 0.315 0.081 0.090 0.139 0.047 0.000 0.047 0.093 0.123 3.223 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2145. 000 1800. 920 124.410

69. 1-40 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY =12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-72

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.000 0.047 0.093 0.093 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.280 0.000 0.000 0.000 0.089 0.000 0.090 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.362 0.000 0.000 0.041 0.000 0.000 0.254
0. 127
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.423 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.047 0.047 0.041 0.089 0.047 0.577 0.404 0.000 0.000 0.093 0.000 0.000 0.047 0.000 0.000 0.000 1.391 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2145. 000 1800. 920 58.030

29. 840 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-73

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 19 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

SECOND QUARTER E2-74

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/l00 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.

.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2110.000 1876. 080
30. 470 0.000 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-75

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2DD9 -

JUN 30, 20D9 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000~

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00.0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 01.000 0.000 0.000 0.000

>=24.

.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2110.000 1876.080

13. 990
0. 000 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY =12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-76

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015

0. 000 0.000 0.015

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.000 0.000 0.015 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2110.000 1876.080 13.960 0.320 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-77

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.095 0.000 0.047 0.095 0.190 0.047 0.047 0.095 0.284 0.332 0.284 0.284 0.332 0.000 0.047 0.000 0.000 2.085 0.047 0.190 0.095 0.047 0.190 0.284 0.474 0.379 0.664 0.474 0.569 0.569 0.521 0.332 0.095 0.284 5.213 0.181 0.319 0.317 0.225 0.323 0.181

0. 912 0.690 0.276 0.456 0.593 1.059 0.822 0.273 0.591 0.275 1.228 0.961 0.335 0.255 0.247 0.709 1.106 1.494 1.113 0.714 0.335
0. 630 1.497 2.385 2.203 1.113 0.310 0.541 0.273 0.000 0.118 0.464 1.013 0.926 0.925 0.427 0.039 0.427 0.500 1.579 0.731 0.273 8.544 0.000 0.000 0.000 0.000 0.000 0.000 0.274 0.118
0. 128 0.086 0.031 0.000 0.092 0.882 0.221 0.000 1.832 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.001 0.000 0.000 0.000 0.010 0.019 0.000 0.600 TOTAL 1.766 2.057 1.115 0.717
0. 925
1. 686 3.885 3.891 3.485 2.442 1.852 3.064 3.442 5.516 3.841 1.945 SUBTOTAL 7.494 16.323 0.043 41.629 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2110.000 1876.080 968.460 878.370 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED'AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-78

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.095 0.095 0.000 0.142 0.000 0.095 0.237 0.237 0.521 0.616 0.379 0.806 0.095 0.142 0.047 0.095 0.047 3.555 0.190 0.237 0.284 0.190 0.190 0.142 0.806 0.569 0.427 0.616 1.185 1.090 0.711 0.095 0.284 0.190 7.204 0.138 0.185 0.413 0.133 0.232 0.632 1.047 0.917 0.909 0.868 0.365 0.726 0.770 0.228 0.182 0.089 0.754 0.791 0.496 0.585 1.092 1.206 1.635 0.870 1.372 0.916 0.166 0.256 0.800 0.874 0.250 0.585 0.116 0.236 0.078 0.000 0.116 0.157 0.699 1.385 1.349 0.504 0.038 0.077 0.154 0.038 0.078 0.116 5.140 0.000 0.030 0.000 0.000 0.000 0.021 0.189 0.100 0.125 0.036 0.000 0.000 0.000 0.020 0.000 0.000 0.521

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.292 1.479 1.414 0.908 1.725 2.395 4.614 4.410 4.797 3.319 2.560 2.291 2.577 1.303 0.890 1.027 SUBTOTAL 7.834 12.650 0.002 37.001 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2110.000 1876.080 833.580 780.720 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-79

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECT ION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.142 0.000 0.000 0.000 0.000 0.000 0.237 0.047 0.000 0.000 0.047 0.000 0.000 0.047 0.142 0.095 0.190 0.190 0.047 0.000 0.000 0.095 0.000

0. 900 0.000 0.047 0.095 0.142 0.000 0.095 0.237 0.095 0.190 0.284 0.616 0.190 0.000 0.000 0.000 0.000 1.991 0.045 0.044 0.139 0.136 0.044 0.089 0.090 0.139 0.183 0.139 0.136 0.139 0.185 0.047 0.000 0.000 1.554 0.366 0.530 0.376 0.339 0.369 0.584 0.373
0. 169 0.245 0.209 0.000 0.083 0.000 0.000 0.000 0.083 3.726 0.039 0.078 0.116 0.000 0.000 0.000 0.078 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.351 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=2 4. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.498 0.700 0.726

0. 664 0.413 0.768 0.825 0.592 0.799 0.822 1.083 0.460
0. 185 0.047 0.095 0.083 8.759 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS F ELEVATED STABILITY CLASS F 2110.000 1876. 080 208.010 184.810 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-80

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.092 0.045 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.231
0. 125 0.206 0.207 0.122 0.123 0.000 0.126 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.909 0.118 0.118 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.275 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=2 4. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.336 0.416 0.207 0.162 0.123 0.047 0.173 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 1.510 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2110.000 1876.080 41.530 31.860 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-81

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 20 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

THIRD QUARTER E2-82

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2192.000 2026.000 19.650 0.910 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED' FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-83

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2D09 -

SEP 3D, 2009 WIND DIRECTION N

NNE NE ENE E

E SE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.087 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2192.000 2026. 000 14.830 1.910 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-84

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE.

S SE S.

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000o 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.091 0.137 0.091 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.365 0.000 0.000 0.000 0.000 0.000 0.088 0.177 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.309 0.041 0.000 0.000 0.000
0. 000 0.119 0.283 0.124 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.567 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000.

0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.041 0.000 0.000 0.000 0.000 0.336

0. 642 0.215 0.046 0.045 0.000 0.000
0. 000
0. 000 0.000
0. 000 1.324 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2192.000 202 6.000 39.390
29. 020 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER-LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-85

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000

0. 137 0.000 0.091 0.274 0.046 0.228 0.137 0.502 0.684
0. 684
0. 684 0.593 0.274 0.091 0.091 0.046 0.182
4. 608
0. 639 0.639 0.137 0.182 0.456
0. 639 1.505 1.186 1.049 1.232 1.460 0.958 0.411 0.411
0. 182 0.456 11.542 1.316 0.479 0.043 0.136 0.219 0.703 1.002 0.872 0.840 0.798 0.757
0. 613 0.567 0.310 0.396 0.563 9.614 1.531 0.740 0.283 0.000
0. 165 2.220 2.078 1.477
2. 375 1.376 0.204 1.343 1.203 1.075 1.234 0.923 18.228 0.151 0.000 0.000 0.000 0.000 0.449 1.490 0.855
0. 630 0.335 0.000 0.000 0.189 1.115 0.596 0.378 6.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.089 0.122 0.000 0.000 0.000 0.055 0.000 0.000 0.297

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL

3. 636 1.949 0.737 0.364 1.068 4.194 6.623 5.107
5. 668 4.547 3.015 3.233 2.461 3.057 2.453 2.503 0.000 50.615 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2192.000 2026.000 1167.380 1109.480 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-86

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.046 0.046 0.046 0.046 0.000 0.000 0.000 0.000 0.137 0.046 0.046 0.000 0.502 0.182 0.365 0.274 0.137 0.411 0.365 0.137 0.456 0.274 0.182 0.411 0.228 0.137 0.137 0.137 0.274 4.106 0.593 0.274 0.365 0.547 0.319 0.456 0.456 0.547 0.411 0.502 0.639 0.228 0.274 0.046 0.182 0.228 6.068

0. 972 0.529 0.483 0.396 1.049 1.007 0.481 0.217 0.221 0.577 0.266 0.264
0. 175 0.133 0.482 0.482 7.734 1.774 0.807 0.481 0.487 1.561 2.448 0.974 0.365
0. 675 0.284 0.082 0.205 0.365
0. 121 0.803 1.477
12. 910 0.076 0.114 0.000 0.000 0.000 0.113 0.111 0.148 0.296 0.075 0.000 0.000 0.000 0.074 0.151 0.075 1.233 0.000 0.026 0.000 0.000 0.000 0.000 0.000 0.020 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.078

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 3.643 2.114

1. 603 1.612 3.385 4.435 2.206 1.798
1. 909
1. 620 1.398
0. 925 1.088 0.557 1.801 2.536 0.000 32.630 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2192.000 2026.000 755.230 715.250 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S.

NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03J24 E2-87

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4

.CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.046 0.091 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.319 0.046 0.228 0.319

0. 182 0.000 0.000 0.000 0.046

'.000 0.046 0.046 0.137 0.046 0.000 0.000 0.000 1.095 0.088 0.223 0.179 0.441 0.349 0.043 0.130 0.000 0.089 0.131 0.000 0.000 0.000 0.000 0.000 0.085 1.758

0. 602 1.696 0.283 0.443 0.491
0. 162 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 198 3.875 0.000 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.735 2.335 0.872 1.112

0. 932 0.205 0.221 0.046 0.089
0. 177 0.046 0.137 0.046 0.000 0.000 0.283 7.235 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2192.000 2026. 000 178.370 158. 600 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-88

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0. C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH-)

0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.046 0.000 0.043 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.176 0.000 0.159 0.079 0.080 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.318 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.043 0.205 0.079 0.123 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.494 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2192.000 2026.000 17.150 10.830 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY =12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-89

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 21 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FOURTH QUARTER E2-90

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000

>=2 4. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2182.000 1920.000 11.770 0.000 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-91

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.040 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.177 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2182.000 1920.000
15. 390 3.870 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY =12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-92

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECT ION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24. 4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.000

0. 000
0. 000
0. 000 0.000 0.000 0.020

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000

0. 000
0. 137
0. 000 0.044 0.020 0.039 0.038 0.000 0.000 0.000 0.000 0.279 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2182.000 1920. 000 18.070 6.090 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-93

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.092 0.046 0.092 0.092 0.092 0.137 0.092 0.275 0.092 0.229 0.275 0.092 0.092 0.137 0.229 2.108 0.275 0.092 0.275 0.092 0.321 0.458

0. 642 0.137
0. 687 0.504 0.458
0. 458 0.596 0.321 0.092 0.137 5.545 0.614 0.753 0.265 0.224 0.614 0.791 0.621 0.489 0.485 0.659 0.445 0.354 0.656 0.309 0.394 0.174 2.330 1.260 0.206 0.040 0.284 1.138 0.725 1.074 1.604 0.688 0.434 0.980 1.914 1.132 1.191 1.947 0.938 0.222 0.038 0.000 0.000 0.076 0.966 0.600 0.637 0.299 0.334 0.375 0.485 0.734 1.304 1.121 8.128 0.120 0.033 0.000 0.000 0.000 0.066 0.393 0.195 0.022 0.120 0.000 0.000 0.110 0.192 0.140 0.127 1.519

>=24.5 0.000 0.000 0.000 0.000 0.000 0.002 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 4.322 2.451 0.830 0.448 1.310 2.624 3.530 2.587 3.710 2.408 1.900 2.442 3.853 2.780 3.257 3.735 SUBTOTAL 7.848 16.945 0.048 42.188 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2182.000 1920.000 1023.200 920.550 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-94

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECT ION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.046 0.092 0.137 0.137 0.321

0. 137 0.183 0.183 0.046 0.183 0.412 0.046 0.183 0.000 0.046 0.137 2.291 0.046 0.046 0.367 0.137 0.275
0. 458 0.550 0.412 0.229 0.092 0.183 0.275 0.275 0.046
0. 137 0.275 3.804 0.351 0.269 0.135 0.356 1.011 0.348 0.838 0.843
0. 665 0.352 0.311 0.135 0.530 0.044 0.088
0. 175 1.247 0.888 0.564 0.856 1.791 2.334 1.388 0.731 1.007 0.514 0.039 0.084
0. 935 0.286 0.404 0.764
0. 672 0.259 0.225 0.114 0.112 0.527
0. 673 0.372
0. 524 0.075 0.297
0. 187 0.000 0.186 0.225 0.188 4.636 0.000 0.000 0.000 0.000 0.000 0.000
0. 646 0.331 0.000 0.072 0.015 0.036 0.022 0.000 0.000 0.000 1.122

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.062 0.044 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 TOTAL 2.361 1.553 1.429

1. 600 3.510 3.804 4.386 2.915 2.472 1.288 1.257 0.773 1.946 0.561
0. 900 1.585 SUBTOTAL 6.447 13.831 0.115 32.339 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2182.000 1920.000 796.670 705. 630 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-95

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

E SE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH)

0. 6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.229 0.046 0.000 0.229 0.092 0.000 0.092 0.092 0.137 0.046 0.183 0.000 0.092 0.000 0.000 0.046 0.000 1.054
0. 137
0. 092 0.183 0.137 0.137 0.092 0.504 0.092 0.321 0.046 0.183 0.046 0.000 0.046 0.183
0. 137 2.337 0.044 0.129 0.043 0.441 0.176 0.354 0.441 0.087 0.178 0.000 0.137 0.087 0.000 0.178 0.044 0.088 2.429 0.763 0.203
0. 653 0.204 0.649 0.970 0.441 0.125 0.207 0.000 0.000 0.000 0.000 0.000 0.000 0.081 4.297 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.991 0.423 1.109

0. 921
0. 963
1. 553 1.478 0.500 0.752 0.229 0.320 0.261 0.000 0.269 0.273 0.353 0.000 10.396 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALiD OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2182. 000 1920.000 252. 950 226. 850 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-96

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.183 0.046 0.046 0.046 0.000 0.000 0.092 0.046 0.183 0.046 0.000 0.046 0.046 0.046 0.046 0.046 0.000 0.733 0.000 0.000 0.046 0.000 0.000 0.000

0. 137 0.046 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.321
0. 000 0.000 0.044 0.044 0.000 0.088 0.264 0.089
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.529 0.121 0.038
0. 164 0.118 0.041 0.081
0. 165 0.000 0.042 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.770 0.000 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.167 0.160 0.300 0.162 0.041 0.260 0.703 0.319 0.134

0. 000 0.046 0.046 0.092 0.137 0.046 0.000
2. 613 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2182.000 1920.000 63.950 57.010 METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-97

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 22 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E2-98

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2009 -

MAR 31, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.047 0.000 0.280 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.140 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.140 0.140 0.047 0.000 0.513 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145

.11 11 2145 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 17.30 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-99

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.047 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.093 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.140 0.000 0.000 0.047 0.373 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 8

8 2145 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 9.0.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 17.27 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-100

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL

0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.047 0.093 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.047 0.047 0.000 0.000 0.093 0.000 0.000 0.000 0.093 0.093 0.000 0.140 0.047 0.000 0.000 0.559 0.280 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.093 0.000 0.186 0.047 0.280
0. 932 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.140
0. 000
0. 000 0.093 0.326 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.093 0.093 0.000 0.233 0.373 0.140 0.047 0.000 0.000 0.093 0.140 0.000 0.000 0.140 0.186 0.186 0.326
0. 326 0.140
0. 373
2. 471 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 53 53 2145 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 14.42 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-101

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.093 0.047 0.000 0.047 0.093 0.000 0.140 0.093 0.233 0.233 0.326 0.233 0.280 0.000 0.186 0.000 0.093 2.005 0.047 0.373 0.466 0.140 0.000 0.233 0.186 0.233 0.326 0.186 0.140 0.093 0.233 0.233 0.326 0.280 3.497 0.280 0.932 0.606 0.093 0.233 0.326 0.420 0.420 0.326 0.326 0.280 0.047 0.513 0.373 0.420 0.233 1.305

1. 678 0.466 0.233 0.186 0.233
0. 653 0.979 2.284 1.026 0.559 0.699 0.793 1.212 1.212 1.259 2.238 1.725 0.373 0.000 0.000 0.140 0.559 1.585 1.958 1.492 1.352 0.233 0.326 1.072 2.564 1.958 0.932 0.746 0.093 0.000 0.000 0.000 0.093 0.886 1.538 0.886 0.047 0.466 0.606 0.186 1.072 1.399 8.951 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.513 0.886 0.233 0.047 0.606 0.093 0.000 0.280 0.420 3.263 4.848 5.455 2.051 0.559 0.420 1.072 2.191 4.848 7.552 4.476 2.704 2.424
2. 611 3.263 5.874 5.641 55.991 5.828 14.779 17.576 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 1201 1201 2145 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 13.46 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-102

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.186 0.047 0.047 0.047 0.047 0.000 0.000 0.000 0.047 0.093 0.186 0.093 0.000 0.093 0.000 0.093 0.000 0.793 0.233 0.047 0.047

0. 093 0.000 0.140 0.047 0.047 0.140 0.140 0.186 0.093 0.186 0.047 0.140 0.093 1.678 0.047 0.186 0.047 0.047 0.047 0.093 0.047 0.140 0.140 0.373 0.093 0.140 0.186 0.186 0.093 0.047 1.911 0.606 0.839 0.326 0.186 0.233 0.839 0.979 1.259 1.445 0.746
0. 653 0.420 0.047 0.140 0.093 0.326 0.746 0.746 0.699 0.466 0.280 0.979 2.284 1.958 3.357 1.585 0.326 0.186 0.186 0.000 0.140
0. 606 0.093 0.140 0.000 0.047 0.000 0.047 0.420 1.212 1.772
0. 653 0.373 0.047 0.047 0.140 0.140 0.186 5.315 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.979 0.559 0.093 0.093 0.140 0.047 0.000 0.000 0.047 1.772 2.005 1.166 0.886 0.559 2.145 4.009 5.641 7.506 3.823 1.865 1.026 0.793 0.513 0.699 1.305 9.138 14.545 2.145 35.711 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 766 766 2145 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 14.29 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-103

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.140 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.186 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.466 0.047 0.000 0.000 0.093 0.233 0.186 0.233 0.280 0.186 0.140 0.093 0.000 0.000 0.000 0.000 0.186 1.678 0.093 0.000 0.093 0.186 0.233 0.186 0.047 0.093 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.026 0.000 0.186

'0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.186 0.093 0.280 0.513 0.466 0.420 0.559 0.280 0.140 0.093
0. 000 0.047 0.047
0. 000 0.233 3.497 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 75 75 2145 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 11.56 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-104

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2009 -

MAR 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.047 0.000 0.000 0.000 0.000 0.093 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.280 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.047 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.047 0.280 0.000 0.000 0.000 0.000 0.047 0.047 0.140 0.373 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.699 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.047 0.140 0.373 0.466 0.140 0.000 0.000 0.000 0.093 0.000 0.000 0.093 1.445 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 31 31 2145 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =

8.13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-105

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 23 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E2-106

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2009 -

JUN 30, 2009 WIND DIRECT ION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2173 0

0 2170 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-107

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2009 -

JUN 30, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2173 0

0 2170 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-108

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NN E NE ENE E

E SE SE S SE S

S SW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2173 1

1 2170 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 26.30 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-109

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.046 0.000 0.092 0.000 0.092 0.138 0.046 0.230 0.369 0.230 0.276 0.000 0.046 0.046 0.000 1.659 0.046 0.138 0.138 0.092 0.184 0.230 0.230 0.323 0.553 0.230 0.323 0.276 0.184 0.276 0.046 0.046 3.318 0.184 0.184 0.092 0.138 0.092 0.461 0.553 0.783 0.369 0.323 0.323 0.645 0.691 0.323 0.553 0.230 0.737 1.106 0.553 0.415 0.276 0.553 0.922 1.198 1.060 0.553 0.737 1.336 1.613 2.350 1.567 1.244 1.014 0.691 0.415 0.000 0.230 1.060 1.198 1.290 1.336 0.691 0.507 0.461 0.783 2.120 0.876 0.599 13.272 0.092 0.184 0.000 0.000 0.138 0.230 0.415 0.553 0.276 0.415 0.000 0.323

0. 461 1.659 0.507 0.046 5.300 0.000 0.000 0.000 0.000 0.000 0.000 0.323 0.046 0.138 0.046 0.000 0.000 0.230 1.060 0.046 0.000 2.120 2.350 1.198 0.783
0. 922
2. 627 3.779 4.240 4.009 2.673 2.120 3.318
3. 963 7.834 3.641 2.166

>=24.5 TOTAL SUBTOTAL 5.945 16.221 1.889 47.742 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2173 1037 1036 2170 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 12.24 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 10

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.000 0.000 0.092 0.000 0.276 0.184 0.138 0.184 0.323 0.092 0.184 0.184 0.046 0.046 0.046 1.843 0.046 0.046 0.138 0.000 0.092 0.184 0.369 0.276 0.415 0.184 0.553 0.323 0.184 0.276 0.138 0.184 3.410 0.046 0.276 0.276

0. 092 0.184 0.184 0.461 0.553 0.461 0.276 0.369 0.507 0.783 0.138 0.138 0.046 4.793 0.230 0.415 0.645 0.276 0.507
0. 829 1.429 1.705 1.475
1. 613 1.060 1.290 1.336 1.106 0.323 0.369 14.608 0.645 0.922 0.415 0.369 0.829 1.014 1.382 1.106
1. 982 1.567 0.276 0.369 0.783 0.461 0.138 0.276 12.535 0.046 0.230 0.138 0.000 0.184 0.184 0.415 0.829 0.691 0.415 0.046 0.046 0.184 0.000 0.000 0.046 3.456 0.000 0.000 0.000 0.000 0.000 0.138 0.230 0.046 0.000 0.046 0.000 0.046 0.000 0.046 0.000 0.000 1.060 1.889 1.613 0.829 1.797 2.857 4.516 4.654 5.207 4.424 2.442 2.765 3.456 2.074 0.783 0.968 0.553 41.336 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2173 899 897 2170 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 11.39 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 11

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2009 -

JUN 30, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM

0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.046 0.000 0.138
0. 092 0.000 0.000 0.046 0.000 0.046 0.000 0.046 0.000 0.461 0.000 0.046 0.046 0.000 0.000 0.000 0.046 0.138 0.046 0.000 0.000
0. 092 0.046 0.000 0.046 0.000 0.507 0.000 0.000 0.046 0.000 0.046 0.000 0.046 0.138 0.184 0.046 0.184 0.138 0.000 0.000 0.046 0.000 0.876 0.046 0.000 0.138 0.276 0.230 0.046 0.323 0.276 0.000 0.461 0.461 0.323 0.092 0.000 0.000 0.000
2. 673 0.323 0.461 0.230 0.276 0.369 0.415 0.276 0.369 0.276 0.230 0.138 0.184 0.230 0.000 0.000
0. 092 3.871
0. 092 0.138 0.184 0.046 0.046 0.092 0.046 0.000 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.783 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.461 0.645
0. 691
0. 645 0.737 0.553 0.876 1.014 0.553 0.829 0.829 0.737 0.415 0.000 0.138
0. 092 9.217 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2173 200 200 2170 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 11.95 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-112

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2009 -

JUN 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000
0. 000
0. 000 0.046
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.000 0.092 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.323 0.092 0.000 0.138 0.138 0.184 0.092 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.737 0.000 0.323
0. 092 0.000 0.046
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.461 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.230 0.323 0.323 0.138 0.230 0.092 0.046 0.138 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.046 1.659 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2173 36 36 2170 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 15.42 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-113

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 24 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E2-114

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECT ION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 1

1 2192 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =

9.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-115

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE, ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 2

2 2192 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =

6.35 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-1 16

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/l00 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.182 0.000 0.000 0.000 0.000 0.000 0.182 0.182 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.365 0.046 0.000 0.000 0.000 0.000 0.274 0.137 0.137 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000
0. 639 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0,000 0.684 0.411 0.228 0.000 0.046 0.000
0. 000
0. 000
0. 000 0.000 0.000 1.414 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 31 31 2192 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =

7.93 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-117

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

E SE SE S SE S

SSW SW_

WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.091 0.000 0.274 0.000 0.091 0.228 0.274 0.228

0. 912 0.593 0.411 0.593 0.456 0.046 0.137 0.046 0.137 4.425 0.411 0.319 0.274 0.137 0.411 0.639 1.232
0. 639
0. 639
0. 639 0.456 0.821 0.502 0.411 0.182 0.274 7.984 0.912 0.319 0.000 0.091 0.228 0.776 0.776 0.365 0.593 0.821
0. 958 0.639 0.137 0.319 0.274 0.456 2.099 1.141 0.365 0.091 0.319 2.828 1.505 1.597 2.144 1.597 1.095 1.551 1.414 1.004
0. 912 1.323 0.593 0.046 0.000 0.000 0.137 1.186 2.281 1.141 1.186 0.776
0. 182 0.547 0.776 1.414
0. 958 0.593 0.000 0.000 0.000 0.000 0.000 0.091 0.365 0.319 0.319 0.274 0.000 0.000 0.000 0.365 0.091 0.000 1.825 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.046 0.000 0.000 0.000 0.046 0.000 0.000 4.015 2.099
0. 639 0.411 1.323 5.794 6.387
4. 973
5. 657 4.562 3.285 4.015 2.874 3.741 2.464 2.783 7.664 20.985 11.816 0.228 55.018 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 1215 1206 2192 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =

9.56 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-118

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW CALM 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.046 0.046 0.046 0.000 0.000 0.000 0.046 0.319 0.137 0.137 0.137 0.091 0.319 0.137 0.182 0.274 0.365 0.182 0.137 0.137 0.274 0.319 0.046 0.091
2. 965 0.182 0.091 0.137 0.137 0.137 0.593 0.547 0.411 0.274 0.137 0.091 0.137 0.137 0.182
0. 182 0.091 3.467 0.365 0.228 0.228 0.228
0. 182 0.456 0.593 0.456 0.182 0.182 0.593 0.274
0. 182 0.046
0. 137 0.182 1.232 1.277 0.821 0.639 0.730 1.825 1.460 0.411 0.411
0. 684 0.456 0.411 0.502 0.502 0.319 1.049 1.505
0. 684
0. 639
0. 182
0. 684
2. 007 0.867 0.228 0.502 0.547
0. 182
0. 182 0.228 0.091 0.547 1.049 0.000 0.137 0.000 0.000 0.000 0.046 0.091 0.046 0.274 0.000 0.000 0.000 0.000 0.046 0.091 0.046 0.776 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.467 2.555
1. 962 1.277 2.053 5.109 3.741 1.870 2.053 1.779 1.505 1.186 1.323 1.186 1.323 2.555 SUBTOTAL 4.516 12.728 10.128 0.046 34.945 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 766 766 2192 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =

9.79 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-119

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.091 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.228 0.046 0.000 0.091 0.046 0.046 0.137 0.091 0.091 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.639 0.000 0.046 0.091 0.046 0.228 0.137 0.000 0.000 0.000 0.000 0.000 0.046 0.000

0. 000.

0.000 0.046

0. 639 0.274 0.182 0.456 0.319 0.547 0.502 0.228 0.000 0.000 0.228 0.000 0.091 0.000 0.000 0.000 0.000 2.828 0.411 1.004
0. 639 0.319 0.091 0.228 0.091 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000
0. 182 3.011 0.000 0.502 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.547 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.730 1.779 1.323 0.821
0. 912 1.049 0.456 0.091 0.000 0.274 0.046
0. 182 0.000 0.000 0.046 0.228
7. 938 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 174 174 2192 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =11.82 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-120

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2009 -

SEP 30, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

  • 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.000 0.046 0.182 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.319 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.228 0.091
0. 137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.547 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2201 12 12 2192 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 13.03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-121

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2009 TABLE 25 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E2-122

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0..000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 0

0 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION>MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-123

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.046

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 092 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.183 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 4

4 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =

7.05 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-124

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.000 0.092 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.367 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 8

8 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED =13.91 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-125

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.092 0.046 0.137 0.046 0.000 0.092 0.137 0.183 0.092 0.183 0.046 0.183 0.137 0.229 1.650 0.229 0.092 0.046 0.046 0.137 0.504 0.321 0.275 0.458 0.092 0.229 0.275 0.275 0.229 0.137 0.000 3.346 0.275 0.550 0.229 0.137 0.321 0.733 0.504 0.367 0.412 0.458 0.550 0.367 0.596 0.367 0.275 0.092 2.566

1. 650 0.367 0.321
0. 642 1.283 0.458 0.779 1.467
0. 962
0. 642 0.871 1.421 1.512 0.962 1.192 1.604 0.183 0.046 0.000 0.183 0.550 1.283 0.917 1.054 0.687 0.596 0.779 1.558 0.550 1.512 2.200 0.321 0.183 0.000 0.000 0.000 0.183 0.733 0.275 0.183 0.137 0.275 0.183 0.504 0.871 0.550 0.412 4.812 0.000 0.000 0.000 0.000 0.000 0.321 0.550 0.092 0.000
0. 137 0.000 0.000 0.183 0.046 0.000 0.000 1.329 5.041
2. 658 0.779 0.550 1.421 3.621
3. 850 2.796 3.712
2. 658 2.383
2. 658 4.583 3.758 3.575 4.125 48.167 6.233 17.094 13.703 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 1051 1051 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 11.91 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-126

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000

0. 000 0.046
0. 000 0.046 0.229 0.092 0.000 0.046 0.000 0.183 0.137 0.092 0.137 0.000 0.092 0.000 0.183 0.137 0.046 0.046 0.000 1.192 0.092 0.046 0.183 0.183 0.046 0.229 0.137 0.275 0.046 0.183 0.229 0.137 0.046 0.137 0.046 0.092 2.108
0. 092 0.046 0.183
0. 137 0.137 0.275 0.321 0.504 0.275 0.275 0.092 0.367 0.229 0.229 0.046 0.000
0. 917 0.596 0.275 0.550
0. 962 2.108
0. 642 1.512 1.283 1.008 0.321 0.183
0. 642 0.458 0.367 0.458 1.192 0.779 0.825
0. 642 1.329 1.421 1.696 0.687 0.871 0.550 0.183 0.137 0.733 0.275 0.321 0.733 0.367 0.229 0.183 0.046 0.137 0.504 0.596 0.550 0.275 0.137 0.229 0.183 0.000 0.092 0.092 0.000
3. 621 0.000 0.000 0.000 0.000 0.000 0.046 1.696 0.504 0.000 0.000 0.046
0. 092 0.046 0.000 0.000 0.000 2.750 1.696 1.742 1.558 2.796 4.766 5.179 4.216 2.750 2.246
1. 100 1.283 1.833 1.283 0.917 1.329 3.208 12.282 12.374 2.429 37.443 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF OF CAL VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVA LM 2182 817 817 2182 0

TIONS METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 13.08 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-127

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2009 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.046 0.092 0.000 0.137 0.046 0.046 0.000 0.000 0.046 0.092 0.000 0.092 0.000 0.092 0.046 0.733 0.046 0.000 0.000 0.046 0.137 0.137 0.092 0.000 0.046 0.046 0.229 0.183 0.046 0.000 0.092 0.046 1.146 0.046 0.046 0.092 0.000 0.092 0.137 0.137 0.137 0.092 0.046 0.000 0.000 0.000 0.046 0.000 0.092 0.962 0.092 0.137 0.367 0.321 0.412 0.596 0.550 0.550 0.321 0.046

0. 046 0.321 0.092 0.000 0.137 0.275 4.262 0.321 0.458 0.733 0.275 0.092
0. 687 0.550 0.046 0.321 0.000 0.000 0.000 0.046 0.000 0.000 0.046 3.575 0.092 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.275 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.642 0.779 1.329 0.687 0.871 1.604 1.375 0.779 0.779 0.183 0.367 0.550 0.275 0.046 0.321 0.504 0.046 11.091 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 242 242 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2010/03/24 MEAN WIND SPEED = 10.44 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-128

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.D C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 20D9 -

DEC 31, 2009 WIND DIRECTION N

NNE NE ENE E

ESE SE S SE S

S SW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1,.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.0DOD 0.0DOD 0.000 0.0ODD 0.0ODD 0.000 0.000

0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.092 0.000 0.046 0.046 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.367 0.000 0.046 0.000 0.000 0.000 0.000 0.046

0. 000 0.092 0.046 0.046 0.046 0.092 0.046 0.046 0.000 0.504 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.137 0.046 0.046 0.000 0.000 0.000 0.000 0.046 0.367 0.000 0.000 0.046 0.092
0. 092 0.000 0.092 0.321 0.092 0.000 0.000 0.000 0.000 0.000 0.046 0.046
0. 825 0.046 0.046 0.000 0.183 0.000 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.412 0.046 0.092 0.046 0.046 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 092 0.183 0.092 0.321 0.137 0.183 0.183 0.412 0.412 0.092 0.092
0. 092 0.137 0.137 0.092 0.092 2.750 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 60 60 2182 0

METEOROLOGICAL FACILITY:

BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =

8.87 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2010/03/24 E2-129

ENCLOSURE 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT (BFN)

JANUARY THROUGH DECEMBER 2009 (See attached)

E3-1

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 Regulatory and BFN ODCM Limits A.

Fission and Activation Gases in Gaseous Effluent:

The release of fission and activation gases is regulated by the dose limits of 10 CFR 50 Appendix I and BFN Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit shall be limited during any calendar quarter to < 5 millirad (mrad) for gamma radiation and < 10 mrad for beta radiation; and during any calendar year to < 10 mrad for gamma radiation and < 20 mrad for beta radiation.

B.

Iodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents.

The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to < 7.5 millirem (mrem), and during any calendar year to < 15 mrem.

C.

Liquid Effluents The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to < 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to < 3 mrem to the total body and < 10 mrem to any organ.

II.

Limitation on Dose Rate A.

Fission and Activation Gases in Gaseous Effluents:

1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to < 500 mrem per year to the total body and < 3000 mrem per year to the skin.
2. The BFN ODCM Section 7.2 determines the maximum noble gas release rate.

E3-2

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009

11.

Limitations on Dose Rate (Continued)

B.

lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents.

I.

The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to 1-131, 1-133, H-3, and particulates with greater than eight days half-lives released in gaseous effluents from the site, shall be limited to < 1500 mrem per year to any organ.

2.

The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.

C.

Liquid Effluents

1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001 -

20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.

2.

For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 jiCi per milliliter (ml) total activity.

III.

Measurements and Approximations of Total Radioactivity A.

Fission and Activation Gases:

1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total Curies of noble gases released.
2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.

E3-3

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 III.

Measurements and Approximations of Total Radioactivity (continued)

B.

lodines and Particulates

1.

lodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total Curies of each particulate and iodine released during the month.

2.

The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample and strontium -89 and -90 are determined by analysis of a quarterly particulate filter composite sample for each release point.

C.

Liquid Effluents

1.

The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow. The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.

2.

The gross alpha and tritium concentrations are measured on a monthly composite sample. The strontium -89 and -90 and iron -55 are measured on a quarterly composite sample.

D.

The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is-specified in ODCM Sections 1/2.2.1 and 1/2.2.2. No liquid or gaseous concentration or dose limits were exceeded.

E3-4

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION 2009 IV.

Batch A. Liquid Units 1.

2.

3.

4.

5.

6.

Number of batches released Each Total time for batches released Minutes Maximum time period for a batch release Minutes Average time period for a batch release Minutes Minimum time period for a batch release Minutes Average stream flow during period of release into a flowing stream Cubic feet per second Ouarter 11 2491 270 226 161 Ouarter Ouaer Quarter 2

3 4

24 5536 295 231 110 7

1791 390 256 188 16 3715 255 232 140 51398 46882 31472 91346 B. Gaseous None C. Abnormal/Unplanned Releases*

Type Number of Releases Nuclide Quarter I

Total Activity Released (Curies)

Quarter Quarter 2

3 Quarter 4

Liquid Three Leak to River Leak to River Leak to River H-3 F-18 H-3 F-18 9.39E+00 2.08E+01 2.11 E+O1 2.11 E+01 4.49E+00 9.97E+00 1.01E+01 1.01E+01 2.32E-01 1.25E-02 H-3 Mn-54 Mn-56 Co-60 Zn-69m 1.29E-01 1.26E-0 1 2.14E-04 1.15E-04 9.95E-04 2.56E-04 4.5 1E-04

  • An explanation of any liquid or gaseous abnormal/unexplained release shall be documented in the summary.

E3-5

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2009 Units Quarter I

Quarter 2

Quarter 3

Quarter 4

Error A. Fission and Activation Products (Does not include tritium, gases, Alpha)

1.

Total Release**

2.

Average Diluted Concentration Released During Period

3.

Percent of Applicable Limit B. Tritium

1.

Total Releases**

2.

Average Diluted Concentration Released During Period

3.

Percent of Applicable Limit C. Dissolved and Entrained Noble Gases

1.

Total Releases

2.

Average Diluted Concentration Released During Period

3.

Percent of Applicable Limit D. Gross Alpha Radioactivity I.

Total Releases

2.

Average Diluted Concentration Released During Period E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)

F. Volume of Dilution Water for Period G. Total CCW Curies 4.52E+00 1.01E+01 1.01E+01 1.01E+01 9

jtCi/mI 3.12E-07 3.40E-07 1.31E-06 6.20E-07 Curies 1.29E+0I 2.56E+01 2.21E+01 2.37E+01 6

latCi/ml 8.88E-07 8.62E-07 2.86E-06 1.46E-06 Curies 1.24E-05 2.01E-06 1.64E-06 1.81E-04 8

ptCi/ml 8.54E-13 6.75E-14 2.13E-13 1.1IE-Il Curies ND*

ND ND ND ND ND ND 48 gCi/mI ND Liters 1.40E+06 2.91E+06 8.02E+05 1.98E+06 3

Liters 1.45E+10 2.97E+10 7.71E+09 1.63E+10 10 Gigagal 2.43 E+02 2.23E+02 2.78E+02 2.50E+02

  • ND -- Not Detected. Dilution flow was not determined for the abnormal release.
    • All four quarters include activity from abnormal releases.
      • The applicable limit is expressed in terms of dose. See Enclosure 1, Tables 5 through 8.

E3-6

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID RELEASES FOR YEAR 2009 - BATCH MODE CURIES Isotope Ouarter Ouarter Ouarter Ouarter (Required by Regulatory (REG) Guide 1.21) 1 2

3 4

1.

Ba-140 ND*

ND ND ND

2.

Ce-141 ND ND ND ND

3.

Co-58 1.02E-06 1.04E-04 ND ND

4.

Co-60 1.43E-03 2.68E-03**

4.89E-04 5.82E-04

5.

Cr-51 ND 1.30E-05 ND 7.75E-05

6.

Cs-134 5.16E-04 2.11E-04 8.91E-05 1.19E-04

7.

Cs-137 4.80E-03 2.58E-03 9.80E-04 1.23E-03

8.

Fe-59 ND ND ND 5.48E-06

9.

1-131 ND ND ND ND

10.

La-140 ND ND ND ND

11.

Mn-54 6.49E-05 5.27E-04**

6.20E-05 3.91 E-05

12.

Mo-99 ND ND ND ND

13.

Nb-95 ND ND ND ND

14.

Sr-89 ND ND ND ND

15.

Sr-90 ND ND ND ND

16.

Tc-99m ND ND ND ND

17.

Xe-133 ND ND ND 6.96E-05

18.

Xe-135 ND 2.01E-06 1.64E-06 1.12E-04

19.

Zn-65 4.89E-04 1.97E-04 7.39E-06 ND

20.

Zr-95 ND ND ND ND

  • - Not Detected
    • - Includes activity from abnormal release.

E3-7

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID RELEASES FOR YEAR 2009 - BATCH MODE CURIES Isotope Others (Not Required by REG Guide 1.21)

1.

F-18

2.

Fe-55 3

Mn-56 4

Zn-69m 5

Kr-88 6

Nb-97 Quarter 4.51E+00" ND**

ND ND 1.24E-05 ND 1.66E-04 ND ND Quarter 2

1.01E+01*

5.56E-04 9.95E-04*

4.5 IE-04*

ND 3.13E-05 2.99E-04 2.65E-05 1.67E-06 Quarter 3

I.OIE+01*

1.82E-05 ND ND ND 6.02E-06 5.29E-06 ND ND Quarter 4

1.01E+01*

ND ND ND ND 5.89E-06 8.30E-06 ND ND 7

8 9

Ag-I 10m Sb-124 1-133

  • Activity from abnormal release.
    • -'Not Detected E3-8

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2009 Units Quarter I

A. Fission and Activation Gases

1. Total Releases
2. Average Release Rate for Period
3. Percent of Applicable Limit B. lodines
1. Total Iodine-131
2. Average Release Rate for Period
3. Percent of Applicable Limit C. Particulates
1. Particulates with half-lives

> eight days

2. Average Release Rate for Period
3. Percent of Applicable Limit
4. Gross Alpha Radioactivity D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Applicable Limit Curies gaCi/sec Curies gaCi/sec Curies taCi/sec Curies Curies pCi/sec ND**

ND 1.64E-04 2.11 E-05 3.19E-05 4.1OE-06 ND 3.91E+01 5.03E+00 Quarter 2

ND ND 3.83E-04 4.87E-05 1.07E-04 1.37E-05 ND 1.92E+01 2.45E+00 Quarter 3

ND ND Quarter Error 4

ND ND 45 4.26E-04 3.77E-04 36 5.36E-05 4.74E-05 5.26E-05 6.62E-06 ND 1.95E+01 2.46E+00 1.21E-05 35 1.53E-06 ND 1.77E+01 21 2.22E+00

  • Applicable Limits are expressed in terms of dose.
    • ND - Not Detected.

See Enclosure 1, Tables I through 4.

E3-9

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 GASEOUS EFFLUENTS - ELEVATED RELEASE Quarter Quarter Quarter Quarter 1

2 3

4 CURIES

1.

Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Others (specify)

Total for Period

2.

lodines 1-131 1-133 Total for Period

  • ND - Not Detected.

ND*

ND ND ND ND ND ND ND ND 1.15E-04 1.11 E-04 2.26E-04 ND ND ND ND ND ND ND ND ND 1.34E-04 2.01 E-04 3.35E-04 ND ND ND ND ND ND ND ND ND 1.52E-04 3.38E-04 4.90E-04 ND ND ND ND ND ND ND ND ND 1.50E-04 2.34E-04 3.83E-04 E3-10

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 GASEOUS EFFLUENTS - ELEVATED RELEASE

.Quarter Quarter Quarter 1

2 3

CURIES

3.

Particulates*

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Y-91m Cs-138 Ba-139 Total for Period*

4.

Tritium Quarter 4

8.63E-06 ND**

ND ND 4.83E-06 ND 5.66E-05 3.OOE-03 6.24E-03 9.3 1E-03 1.83E+01 8.46E-06 ND ND 6.65E-07 ND ND 8.01E-06 2.89E-03 6.60E-03 9.5 1E-03 3.08E+00 1.08E-05 ND ND ND ND ND 1.5 1E-05 1.61E-03 5.46E-03 7.1OE-03 2.66E+00 1.21 E-05 ND ND ND ND i.83E-06 3.20E-05 ND 1.0IE-02 1.0 1E-02 2.85E+00

  • Includes all nuclides, even those with less than an eight day half-life.
    • ND - Not Detected.

E3-11

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 GASEOUS EFFLUENTS - GROUND RELEASE CURIES Ouarter Ouarter Ouarter Ouarter 1

2 3

4

1.

Fission Gases Kr-85m ND*

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others(specify)

NONE Total for Period ND ND ND ND

2.

lodines 1-131 1.11E-05 2.OOE-05 1.26E-05 1.50E-05 1-133 1.45E-05 1.75E-05 2.70E-05 5.36E-06 Total for Period 2.56E-05 3.75E-05 3.96E-05 2.04E-05

  • ND - Not Detected.

E3-12

CURIES

3.

Particulates*

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Y-91m Cs-138 Ba-139 Total for Period*

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 GASEOUS EFFLUENTS - GROUND RELEASE Quarter Quarter Ouartei 1

2 3

ND**

ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Ouarter 4

ND ND ND ND ND ND ND 2.9 1E-03 1.86E-03 4.77E-03 2.15E+00 1.20E-05 ND I.OOE-04 1.12E-04 ND ND 9.44E-04 9.44E-04 ND ND ND 0.OOE+00 5.64E-01

4.

Tritium 5.64E+00 2.29E+00

  • Include all nuclides even those with less than an eight day half-life.
    • ND - Not Detected.

E3-13

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Quarter Quarter Ouarter Ouarter 1

2 3

4 1

Fission Gases Kr-85m ND**

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others(specify)

NONE Total for Period ND ND ND ND

2.

lodines 1-131 3.80E-05 2.29E-04 2.62E-04 2.12E-04 1-133 8.35E-05 9.44E-04 8.86E-04 6.49E-04 Total for Period 1.22E-04 1.17E-03 1.15E-03 8.61E-04

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • ND - Not Detected.

E3-14

CURIES

3.

Particulates**

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Mn-54 Mn-56 Co-58 Co-60 Zn-65 Zn-69m Y-91m EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

Quarter Ouarter Ouarter 1

2 3

)uarter 4

ND***

ND ND 4.89E-06 ND ND 3.06E-06 ND 6.07E-06 4.42E-06 ND ND ND ND ND ND 4.63E-06 ND ND 6.01 E-06 8.27E-04 1.09E-05 7.01 E-05 6.64E-06 4.33E-05 2.91E-04 ND ND ND ND ND ND 2.40E-05 1.30E-03 ND 1.78E-05 ND ND 1.46E-05 ND ND ND ND ND ND ND ND ND ND ND ND 1.52E-04

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • Includes all nuclides, even those with less than an eight day half-life.
      • ND - Not Detected.

E3-15

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2009 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Quarter Ouarter Quarter Quarter Particulates** (Continued) 1 2

3 4

Others (specify)

Mo-99 3.11 E-06 7.90E-06 3.54E-06 1.80E-06 Tc-99m 3.03E-06 7.70E-06 3.45E-06 1.76E-06 Ba-139 ND 7.37E-04 ND 2.66E-03 Total for Period**

2.46E-05 2.01E-03 1.37E-03 2.82E-03

4.

Tritium 1.51E+01 1.39E+01 1.63E+01 1.27E+OI

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • Includes all nuclides, even those with less than an eight day half-life.
      • ND - Not Detected.

E3-16

BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2009 Solid Radioactive Waste Shipped for Processing or Disposal Resins, Filters, and.

Evaporator Bottoms Volume Curies Shipped Waste Class ft3M3Curies A2.53E+03 7.17E+01 1.30E+02 BO.OOE+OO O.OOE+OO O.OOE+OO CO.OOE+OO O.OOE+OO O.OOE+OO ALL 2.53E+03 7.17E+o1 1.30E+02 Major Nuclides for the Above Table:

1) 2)

3) 4)

5) 6)

7) 8)

9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22)

Nuclide CO-60 CS-137 FE-55 MN-54 ZN-65 CS-134 NI-63 AG-110M CO-58 CE-144 TC-99 CR-51 SR-90 PU-241 C-14 FE-59 H-3 1-131 SB-124 NB-95 ZR-95 AM-241 Percentage 4.95E+01 2.25E+01 1.14E+01 4.72E+00 3.8 1E+00 3.15E+00 1.82E+00 1.43E+00 5.42E-01 4.66E-0 I 2.90E-01 1.21E-0I 1.05E-01 6.03E-02 2.26E-02 1.88E-02 5.69E-03 4.06E-03 1.90E-03 1.69E-03 1.37E-03 9.04E-04 Curies 6.46E+01 2.94E+0 I 1.49E+01 6.16E+00 4.97E+00 4.11 E+00 2.38E+00 1.87E+00 7.08E-01 6.08E-01 3.79E-01 1.58E-01 1.37E-01 7.87E-02 2.95E-02 2.46E-02 7.43E-03 5.30E-03 2.48E-03 2.20E-03 1.79E-03 1.18E-03 E3-17

23) 24) 25) 26) 27) 28) 29) 30) 31) 32)

Nuclide SR-89 PU-238 CM-243 CM-244 CO-57 CM-242 PU-239 PU-240 LA-140 CU-64 Percentage 7.45E-04 7.09E-04 4.47E-04 4.47E-04 1.53E-04 1.16E-04 8.96E-05 8.96E-05 6.35E-07 1.85E-14 Curies 9.73E-04 9.25E-04 5.84E-04 5.83E-04 2.OOE-04 1.51 E-04

1. 17E-04 1.17E-04 8.29E-07 2.41E-14 Dry Active Wat oueCries Shpped waste Class ft3M3Cries A5.30E+04 1.50E+03 1.04E+0 BO.OOE+OO O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 5.30E+04 1.50E+03 1.04E+00 Major Nuclides for the Above Table:

1) 2)

3) 4)

5) 6)

7) 8)

9) 10)

Nuclide CO-60 CS-137 FE-55 CS-134 MN-54 ZN-65 TC-99 NI-63 C-14 CO-58 Percentage 4.86E+01 2.83E+01 9.33E+00 5.96E+00 4.37E+00 1.28E+00 8.25 E-0 1 7.46E-0 1 3.42E-0 1 4.57E-02 E3-18 Curies 5.08E-0 I 2.96E-01 9.75E-02 6.23E-02 4.57E-02 1.34E-02 8.62E-03 7.79E-03 3.57E-03 4.77E-04

11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) 25) 26) 27) 28) 29)

Nuclide CR-51 NB-95 AG-1 IOM SR-90 FE-59 H-3 ZR-95 CE-144 NI-59 PU-241 CO-57 SR-89 AM-241 CM-243 CM-244 PU-238 CM-242 PU-239 PU-240 Percentage 2.70E-02 2.60E-02 2.32E-02 2.08E-02 1.42E-02 1.12E-02 6.7 1E-03 3.17E-03 2.76E-03 9.12E-04 5.97E-04 4.39E-04 1.45E-05 5.85E-06 5.85E-06 5.50E-06 4.84E-06 1.34E-06 1.34E-06 Curies 2.82E-04 2.72E-04 2.42E-04 2.177E-04 1.48E-04 1.17E-04 7.01E-05 3.3 1E-05 2.88E-05 9.53E-06 6.24E-06 4.59E-06 1.52E-07 6.11E-08 6.11E-08 5.75E-08 5.06E-08 1.40E-08 1.40E-08 irradiated Components VoueCries Shpped Waste Class ft3M3Cries AO.OOE+/-OO O.OOE+/-OO O.OOE+OO BO.OOE+OO O.OOE+O0 0.OOE+OO CO.OOE+OO O.OOE+OO O.OOE+OO ALO.OOE+OO O.OOE+OO O.OOE+OO Major Nuclides for the Above Table: N/A E3-19

Other Waste Volume Curies (Combined Packages)

Shipped Waste Class ft 3 M 3 Curies A

5.26E+03 1.49E+02 3.95E+01 B

O.OOE+oo O.OOE+oo O.OOE+oo C

O.OOE+03 O.OOE+02 O.OOE+01 ALL 5.26E+03 1.49E+02 3.95E+01 Major Nuclides for the Above Table:

Nuclide Percentage Curies

1)

CO-60 5.02E+01 1.98E+01

2)

CS-137 1.81E+01 7.15E+00

3)

FE-55 1.50E+01 5.90E+00

4)

MN-54 5.18E+00 2.04E+00

5)

ZN-65 4.14E+00 1.63E+00

6)

NI-63 2.16E+00 8.53E-01

7)

CS-134 2.15E+00 8.47E-01

8)

AG-I IOM 8.47E-01 3.34E-01

9)

CO-58 7.94E-01 3.13E-01

10)

CE-144 5.58E-01 2.20E-0I

11)

TC-99 2.69E-01 1.06E-01

12)

CR-51 2.28E-01 8.99E-02

13)

SR-90 1.15E-01 4.55E-02

14)

PU-241 6.14E-02 2.42E-02

15) 1-131 5.18E-02 2.04E-02
16)

BA-140 4.95E-02 1.95E-02

17)

CE-141 2.84E-02 1.12E-02

18)

FE-59 1.92E-02 7.55E-03

19)

C-14 7.89E-03 3.11E-03

20)

SR-89 1.77E-03 6.99E-04

21)

AM-241 9.67E-04 3.81E-04

22)

RA-226 9.36E-04 3.69E-04

23)

PU-238 7.51E-04 2.96E-04

24)

CM-243 4.82E-04 1.90E-04

25)

CM-244 4.82E-04 1.90E-04

26)

NI-59 4.08E-04 1.61E-04 E3-20

27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37)

Nuclide CM-242 PU-239 PU-240 LA-140 H-3 NB-95 CO-57 ZR-95 SB-124 CU-64 NA-24 Percentage 1.27E-04 8.75E-05 8.75E-05 6.39E-05 4.14E-05 1.83E-05 1.08E-05 9.23E-06 5.63E-06 1.14E-10 3.25E-13 Curies 5.01 E-05 3.45E-05 3.45E-05 2.52E-05 1.63E-05 7.20E-06 4.24E-06 3.64E-06 2.22E-06 4.51E-I I 1.28E-13 Sum~ of All~ Low-LevelVoueCrs Waste Shipped from Shppedc Site Waste Class ft3M3Cre s

A6.

08E+04 1.72E+ 03 1.71E+02 BO.OOE+OO O.OOE+OO 0.OOE+OO CO.OOE+OO O.OOE+OO 0.OOE+OO AL6.08E+04 1.72E+03 1.71E+02 Major Nuclides for the Above Table:

1) 2)

3) 4)

5) 6)

7) 8)

9) 10) 11)

Nuclide CO-60 CS-137 FE-55 MN-54 ZN-65 CS-134 NI-63 AG-0I OM CO-58 CE-144 TC-99 Percentage 4.96E+0 1 2.16E+0 I 1.22E+0I 4.82E+00 3.87E+00 2.93E+00 1.89E+00 1.29E+00 5.96E-01 4.84E-01 2.88E-0 1 Curies 8.49E+01 3.69E+01 2.09E+01 8.24E+00 6.62E+00 5.02E+00 3.24E+00 2.20E+00 1.02E+00 8.28E-01 4.93E-01 E3-21

12)

CR-51 1.45E-01 2.48E-01 Nuclide Percentage Curies

13)

SR-90 1.06E-01

!.82E-01

14)

PU-241 6.02E-02 1.03E-01

15)

C-14 2.12E-02 3.62E-02

16)

FE-59 1.89E-02 3.23E-02

17) 1-131 1.51E-02 2.58E-02
18)

BA-140 1.14E-02 1.95E-02

19)

CE-141 6.55E-03 1.12E-02

20)

H-3 4.43E-03 7.57E-03

21)

NB-95 1.45E-03 2.48E-03

22)

SB-124 1.45E-03 2.48E-03

23)

ZR-95 1.09E-03 1.86E-03

24)

SR-89 9.82E-04 1.68E-03

25)

AM-241 9.12E-04 1.56E-03

26)

PU-238 7.13E-04 1.22E-03

27)

CM-243 4.53E-04 7.75E-04

28)

CM-244 4.52E-04 7.73E-04

29)

RA-226 2.16E-04 3.69E-04

30)

CO-57 1.23E-04 2.11 E-04

31)

CM-242

1. 1 8E-04 2.01E-04
32)

NI-59 1.11 E-04 1.90E-04

33)

PU-239 8.83E-05 1.51E-04

34)

PU-240 8.83E-05 1.51E-04

35)

LA-140 1.52E-05 2.60E-05

36)

CU-64 2.64E-11 4.51E-11

37)

NA-24 7.48E-14 1.28E-13 E3-22

BROWNS FERRY NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT

SUMMARY

OF ABNORMAL/UNPLANNED RELEASES 2009 The release of radioactive material to the environment from Browns Ferry has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix I.

No abnormal gaseous releases occurred in 2009. Three abnormal liquid releases occurred in 2009. A leak to the station sump was detected on January 8, 2009 (Problem Evaluation Reports (PERs) 160665 and 162203). This leak was initially reported in the 2008 effluent report. A leak was detected in the residual heat removal system on April 25, 2009. The cooling water released when the system was placed in service constituted an abnormal liquid release (PERs 169593 and 169792). A leak in a seal cooler resulted in an abnormal liquid release (PER 218437) due to the Condensate system leaking into raw cooling water (RCW). Each of these releases is discussed in more detail below.

Samples of Units 1, 2, and 3 station sumps are analyzed monthly for contamination. No samples showed activity in 2008; however, the Unit I sample collected in January 2009, showed traces of both F-18 (1.3E-07 gtCi/ml) and H-3 (1.5E-06 p.Ci/ml). The total release for 2009 is estimated at F-18 (I.4E-01 Ci) and H-3 (3.6E-01 Ci). The sumps empty into the river. This release resulted in a small increase (<4E-06 mrem) in the calculated dose for 2009.

On April, 25, 2009 a leak was detected in the Unit 2 Loop 11 of the Residual Heat Removal (RHR) system.

Loop II RHR was secured and Loop I RHR was placed in service. The RHR water empties into the river.

This abnormal release resulted in a release of 2.14E-04 Ci of H-3, 1.15E-04 Ci of Mn-54, 9.95E-04 of Mn-56, 2.56E-04 Ci of Co-60, and 4.5 1E-04 Ci of Zn-69m. This release resulted in a small increase (<IE-05 mrem) in the calculated dose for 2009.

On February 24, 2010, a leak in the 3B Injection Water Pump seal cooler was discovered. This leak from the Condensate system into the Raw Cooling Water (RCW) constituted an abnormal release. The Injection Water Pump was isolated and the seal cooler repaired. A loss of inventory in the Unit 3 Condensate Storage Tank had been under investigation; however, the source of the loss had not been discovered until this time. An estimated flow of 20 gal/min over 319 days in 2009, resulted in a release of 72.4 Ci of H-3 and 34.6 Ci of F-18 (half-life 109 min). Negligible dose resulted from the F-18 activity due to it's short half-life. The total dose from this leak (5.2E-04 mrem) was a small fraction of the yearly limit of 3.0 mrem.

Ground Water Monitoring Onsite groundwater monitoring locations were sampled during the year. These locations were not part of BFN Radiological Environmental Monitoring Program (REMP). The purpose of these shallow wells was to monitor for potential leaks from plant equipment. Trace levels of tritium were detected in several of these monitoring locations. BFN initiated a groundwater study to identify the source of the tritium.

Results from a groundwater study completed in June 2006 suggest the source of the tritiated groundwater is associated with the Radwaste/Condensate Transfer tunnel. Water that may leak into the tunnel could egress via expansion joints and/or cracks through the tunnel wall. These joints and/or cracks were grouted during 2008 with several more leaks grouted in 2009. The highest concentration identified in the groundwater for the year was 2007 pCi/L. Groundwater and surface water level measurements during the study indicated the return channel and subsequently the Tennessee River will ultimately be recipient to tritiated groundwater discharge from the site. The estimated groundwater/channel water dilution ratio is E3-23

1:20,000 at a rate of approximately 0.5 gpm. Using the highest measured tritium concentration in groundwater, (2007 pCi/L at the source of the plume) the aqueous tritium concentration in the channel would be 0.10 pCi/L. Assuming this concentration and release rate for the entire year results in a release of approximately 2.0E-03 Ci/year. This is a small fraction of the liquid radwaste and gaseous releases for 2009 and would result in a small fraction of the reported dose.

Missed Compensatory Samples During the reporting period, January 1 through December 31, 2009, there were no missed compensatory samples.

Liquid Radwaste or Temporary Storage Tanks BFN does not have outside liquid radwaste or temporary storage tanks that can be discharged directly to the environs (Technical Requirements Manual 3.7.1).

Changes to the Radwaste System and Changes to the Process Control Program (PCP)

In calendar year 2009, Browns Ferry had no changes to the radwaste system and no changes to the Process Control Program (PCP).

E3-24

ENCLOSURE 4 INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT BROWNS FERRY NUCLEAR PLANT (BFN)

JANUARY - DECEMBER 2009

INOPERABLE RADIOLOl1CAL EFFLUENT INSTRUMENTATION REPORT 2009 This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (Offsite Dose Calculation Manual (ODCM)) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.

During the reporting period, January 1 through December 31, 2009, there was no radioactive gaseous or liquid effluent monitoring instruments out of service for greater than 30 days.