PEACH BOTTOM ATOMIC POWER STATION Unit Numbers 2 and 3 Docket Numbers 50-277 and 50-278 Unit Number 1 Docket Number 50-171 PBAPS Independent Spent Fuel Storage Installation Docket Number 72-29 RADIOACTIVE EFFLUENT RELEASE REPORT NO. 52 JANUARY 1, 2009 THROUGH DECEMBER 31, 2009 Submitted to The United States Nuclear Regulatory Commission Pursuant to Facility Operating Licenses DPR-44 and DPR-56
(Page Intentionally Left Blank)
TABLE OF CONTENTS SECTION PAGE Introduction 1 Supplemental Information 3 Regulatory Limits 5 Maximum Permissible Concentrations 6 Average Energy 6 Measurements and Approximations of Total Radioactivity 6 Batch Releases 8 Average Stream Flow 9 Abnormal Releases 9 Changes to ODCM 11 Minimum Detectable Concentrations 12 Violations 12 Effluent Summary 13 Gaseous Effluents - Summation of All Releases 15 Gaseous Effluents for Elevated Release Point - Main Stack 16 Gaseous Effluents for Ground Level Release Points - 17 Unit 2 and Unit 3 Roof Vents & Aux Boiler Stack Liquid Effluents - Summation of All Releases 18 Liquid Effluents Release Points - Liquid Radwaste, RHR Leaks 19
& Tritium Leaks Solid Waste and Irradiated Fuel Shipments 21 Solid Waste Shipped 23 Irradiated Fuel Shipments 24 Changes to Process Control Program (PCP) 25 Radiological Impact on Man 27 Radiological Impact on Man 29 40 CFR 190 Doses 29 Liquid and Gaseous Effluent Radiation Monitors and 29 Instrumentation Meteorological Data 31 Appendix A ERRATA Data Section 89 Appendix B Revised copy of the ODCM 91 Technical Concurrences: (for accuracy of information)
I MaaerDt Ch~mi~stry' I ~waste Manager IIDate'
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC INTRODUCTION In accordance with the Reporting Requirements of Technical Specification 5.6.3 applicable during the reporting period, this report summarizes the Effluent Release Data for Peach Bottom Atomic Power Station Units 2 and 3 for the period January 1, 2009 through December 31, 2009. The notations E+ and E-are used to denote positive and negative exponents to the base 10, respectively.
The release of radioactive materials during the reporting period was within the Offsite Dose Calculation Manual Specification limits.
There were four unplanned releases of liquid radioactive material. Two releases were from RHR heat exchangers, one was from a groundwater tritium plume and one was from the U2 Yard Drain Sump.
There were no gaseous or liquid radioactive releases from the Independent Spent Fuel Storage Installation, NRC Docket No. 72-29 (ISFSI).
There were no changes made to RW-AA-100 "Process Control Program for Radioactive Waste" in 2009.
There were no changes needed for the 2008 Effluent Report. Therefore, Appendix A is intentionally left blank.
There were changes made to the ODCM during the 2009 reporting period. A copy of the revised ODCM Revision 13 is attached with this document and included as Appendix B. Each change is identified by markings in the margin of affected pages, indicating the area of the page that was change and the date (month/year) the change was implemented.
Exelon common procedures, which provide consistent expectations and standards for Radioactive Effluents Controls Program, were used to generate this report. They are:
- CY-AA-170-000, Radioactive Effluent and Environmental Monitoring Program
- CY-AA-170-100, Radiological Environmental Monitoring Program
- CY-AA-1 70-200, Radioactive Effluent Controls Program
- CY-AA-170-300, Offsite Dose Calculation Manual Administration
- CY-AA-170-2100, Estimated Errors of Effluent Measurement
- CY-AA-170-3100, Offsite Dose Calculation Manual Revisions I
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 2
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 1 Supplemental Information 3
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 4
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC
- 1. Regulatory Limits A. Noble Gases:
- 1. <500 mrem/Yr - total body ODCMS 3.8.C.1 .a
< 3000 mrem/Yr - skin
- 2. <10 m rad - air gamma quarterly air dose limits
<20 mrad - air beta ODCMS 3.8.C.2.a and b
- 3. <20 mrad - air gamma yearly air dose limits
< 40 m rad - air beta ODCMS 3.8.C.2.c and d B. lodines, Tritium, Particulates with Half Life > 8 days:
- 1. < 1500 mrem/Yr - any organ - ODCMS 3.8.C.1.b
- 2. *15 mrem - any organ - quarterly dose limits ODCMS 3.8.C.3.a
- 3. <30 mrem - any organ - yearly dose limits ODCMS 3.8.C.3.b C. Liquid Effluents
- 1. Concentration < 10 times 10 CFR 20, - ODCMS 3.8.B.1.a Appendix B, Table 2, Col. 2
- 2. *3.0 mrem - total body - quarterly dose limits
<10 mrem - any organ ODCMS 3.8.B.2.a
- 3. *6.0 m rem - total body - yearly dose limits
<20 mrem - any organ ODCMS 3.8.B.2.b D. 40 CFR 190 and 10 CFR 72.104
- 25 mrem - total body ODCMS 3.8.D.1 .a
<75 mrem - thyroid ODCMS 3.8.D.1 .b
< 25 mrem - any other organ ODCMS 3.8.D.1 .c
< 3.0 mrem - from liquid and ODCMS 3.8.D.1.d gaseous effluent
< 55 mrem - thyroid from gases ODCMS 3.8.D.1 .e 5
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC
- 2. Maximum Permissible Concentrations:
Gaseous dose rates rather than effluent concentrations are used to calculate permissible release rates for gaseous releases. The maximum permissible dose rates for gaseous releases are defined in ODCMS 3.8.C.la. and 3.8.C.1.b.
The Effluent Concentrations Limits (ECL) specified in 10 CFR 20, Appendix B, Table 2, Column 2 times 10, for identified nuclides, are used to calculate permissible release rates and concentrations for liquid release per Peach Bottom Offsite Dose Calculation Manual Specification 3.8.B.1.
The total activity concentration for all dissolved or entrained gases is limited to
< 2E-04 liCi/ml.
- 3. Average Energy:
The Peach Bottom ODCM limits the dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. Therefore, the average beta and gamma energies of the radionuclide mixture in releases of fission and activation gases as described in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," are not applicable to Peach Bottom.
- 4. Measurements and Approximations of Total Radioactivity:
A. Fission and Activation Gases:
The method used for Gamma Isotopic Analysis is the Canberra Genie System with a gas Marinelli beaker. Grab samples are taken and analyzed at least monthly to determine the isotopic mixture of noble gas activity released for the month. Airborne effluent gaseous activity was continuously monitored and recorded in accordance with ODCMS Table 4.8.C.1. The data from the noble gas radiation monitor was analyzed to report noble gas effluent activities. When no activity was found in the grab isotopic analysis, the isotopic mixture was assumed to be that specified in ODCM IV.B. The activity released is listed as Unidentified in the Attachment 2 Tables. If activity was found in the grab isotopic analysis, the isotopic mixture for the Noble Gas Monitor was determined from that isotopic mixture.
6
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC B. lodines:
The method used is the Canberra Genie System with a charcoal cartridge.
Iodine activity was continuously sampled and analyzed in accordance with ODCMS Table 4.8.C.1.
C. Particulates:
The method used is the Canberra Genie System with a particulate filter (47 mm).
Particulate activity was continuously sampled and analyzed in accordance with ODCM Table 4.8.C.1.
Composite particulate air samples were submitted to an offsite vendor laboratory for analysis of Sr-89, Sr-90 and gross alpha.
D. Liquid Effluents:
Gamma isotopic activity concentrations are determined on each batch of liquid effluent prior to release using the Canberra Genie System in accordance with ODCMS Table 4.8.B.1. The total activity of a released batch is determined by multiplying each nuclide's concentration by the total volume discharged.
Composite liquid radwaste samples counted for tritium and submitted to an offsite vendor laboratory for analysis of Fe-55, P-32, Sr-89, Sr-90 and gross alpha.
About 1,200 gal of water from Peach Bottom Unit 1 that were contaminated with tritium (< 0.03 Ci) were transported to Units 2 & 3 radwaste system and discharged through the laundry drain system as normal discharges. The dose contributions and isotope quantities from the releases were added to this Radioactive Effluent Release Report for the applicable reporting periods.
E. Estimated Total Error Present CY-AA-170-2100, Estimated Errors of Effluent Measurements, provides the methodology to obtain an overall estimate of the error associated with radioactive effluents.
7
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC
- 5. Batch Releases:
A. Liquid:
QTR 1 QTR 2 QTR 3 QTR 4 Number of batch releases: 24 55 50 23 Total Time for batch releases (minutes) 4.20E+03 1.30E+04 1.14E+04 5.26E+03 Maximum time period for batch release 270 319 275 275 (minutes):
Average time period for batch release 175 236 228 229 (minutes):
Minimum time period for batch release 28 25 37 35 (minutes):
Average Stream Flow
- Dilution volume (liters): 1.24E+10 6.60E+10 5.56E+10 2.52E+10
- Stream flow not used for dose calculations B. Gaseous:
QTR 1 QTR 2 QTR 3 QTR 4 Number of batch releases: 0 0 0 0 Total Time for batch releases (minutes) 0 0 0 0 Maximum time period for batch release 0 0 0 0 (minutes):
Average time period for batch release 0 0 0 0 (minutes):
Minimum time period for batch release 0 0 0 0 (minutes):
8
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC
- 6. Average Stream Flow:
The river flow is not used for dose calculations. The actual discharge of circulating water is used for liquid dose calculations. The circulating water varies from 675,000 gpm in the winter to 1,350,000 gpm in the summer.
- 7. Abnormal Releases: Four abnormal release sources A. Liquid:
- 1. Event description - 2C Residual Heat Removal (RHR) to High Pressure Service Water (HPSW) leak On 08/01/2005, routine sampling of the HPSW effluent to the discharge canal detected low-level radioactive contamination. Subsequent investigation determined that a trace amount of condensate stay-full or primary coolant water was leaking through the Unit 2C RHR heat exchanger into the 2A loop of the HPSW system. The 2C RHR continued to be a source of contamination to the beginning of 2009. The leak rate range was 0.0438 GPM to the end of February 2009. The 2C RHR heat exchanger was repaired February 28, 2009 Analysis of Releases It was estimated that the contaminated water released to the discharge canal for all of 2009 was responsible for 9.92E-05 mrem total body dose (Adult), and 1.66E-04 mrem Critical Organ (Teen Liver) dose. This dose contribution was well below the limits specified in the ODCM.
Samples were analyzed for all the parameters of radioactive effluent releases. Composite liquid radwaste samples counted for tritium and submitted to an offsite vendor laboratory for analysis of Fe-55, P-32, Sr-89, Sr-90 and gross alpha. The maximum concentration from several analyses was used to ensure conservative measures of activity released.
The dose contributions and isotope quantities from the releases were added to this Radioactive Effluent Release Report for the applicable reporting periods.
- 2. Event description - 3A Residual Heat Removal (RHR) to High Pressure Service Water (HPSW) leak On 04/08/2008, routine sampling of the HPSW effluent to the discharge canal detected low-level radioactive contamination. Subsequent investigation 9
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC determined that a trace amount of condensate stay-full or primary coolant water was leaking through the Unit 3A RHR heat exchanger into the 3A loop of the HPSW system. The 3A RHR continued to be a source of contamination to the end of 2009. The leak rate ranged from was 0.0642 GPM to 0.0529 GPM throughout the year.
Analysis of Releases It was estimated that the contaminated water released to the discharge canal for all of 2009 was responsible 2.82E-03 mrem total body dose (Adult), and 4.57E-03 mrem Critical Organ (Teen Liver) dose. This dose contribution was well below the limits specified in the ODCM.
Samples were analyzed for all the parameters of radioactive effluent releases. Composite liquid radwaste samples counted for tritium and submitted to an offsite vendor laboratory for analysis of Fe-55, P-32, Sr-89, Sr-90 and gross alpha. The dose contributions and isotope quantities from the releases were added to this Radioactive Effluent Release Report for the applicable reporting periods.
- 3. Event description - Yard Drain Sump During 2009, routine sampling of the Yard Drain Sumps showed no gamma activity but low concentrations of tritium. The tritium was measured to be between 9.24E-07 and 6.08E-06 uCi/ml.
Analysis of Release It was estimated that the contaminated water released to the discharge canal at a rate of 23 gpm. With the tritium concentrations between 9.24E-07 and 6.08E-06 uCi/mL, the water released was responsible for 1.85 mrem total body dose (Child), and 1.85E-06 mrem Critical Organ (Child) dose. This dose contribution was well below the limits specified in the ODCM.
Representative samples were analyzed for gamma activity and tritium.
The dose contributions and isotope quantities from the releases were added to this Radioactive Effluent Release Report for the applicable reporting periods.
10
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC
- 4. Event description - Ground Water Plume During 2009, during the sampling and analysis of the Radiological Ground Water Protection Program (RGPP), tritium was measured at several locations around the site. The ground water that has detectable tritium has been determined to discharge into the intake or discharge canal. The highest concentration of tritium measured varied from 3.04E-06 to 7.15E-05 uCi/ml.
Analysis of Releases It was estimated that the ground water flowed to the discharge canal at a rate of 175 gpm. With the concentration ranging from 3.04E-06 to 7.15E-05 uCi/ml, the ground water released to the discharge canal was responsible for 1.08E-04 mrem total body dose (Child), and 1.08E-05 mrem Critical Organ dose (Child). This dose contribution was well below the limits specified in the ODCM.
B. Gaseous:
No abnormal releases.
- 8. Changes to the ODCM:
A revised copy of the ODCM Revision 13 is attached as Appendix B of this document for the 2009 reporting period. Each change is identified by markings in the margin of affected pages. The major changes to the ODCM were addition of dose factors and update of X/Q values. The details of all the changes are included in Appendix B.
11
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC
- 9. Minimum Detectable Concentrations:
A. Liquid:
If a radionuclide was not detected, < LLD was reported for that isotope. Samples were analyzed with techniques that achieved the required Lower Limits of Detection (LLD) as specified in Offsite Dose Calculation Manual Specification Table 4.8.B.1, Radioactive Liquid Waste Sampling and Analysis. In all cases, the LLD requirements were satisfied.
B. Gaseous:
If a radionuclide was not detected, < LLD was reported for that isotope. Samples were analyzed with techniques which achieved the required Lower Limits of Detection (LLD) as specified in Offsite Dose Calculation Manual Specification Table 4.8.C.1, Radioactive Gaseous Waste Sampling and Analysis from Main Stack and Vent Stack. In all cases, the LLD requirements were satisfied.
- 10. Violations:
A. There were no violations for the 2009 reporting period 12
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 2 Effluent Summary 13
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 14
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Gaseous Effluents - Summation Of All Releases Period: 2009 Unit: Peach Bottom Units 2 &3 A. Fission & Activation Gases Unit Quarter Quarter Quarter Quarter Est. Total 1 2 3 4 Error%
- 1. Total Release Ci 2.23E+02 3.84E+02 2.49E+02 1.66E+02 3.51E+01
- 2. Average release rate for the period pCi/sec 2.84E+01 4.88E+01 3.1 7E+01 2.11 E+01
- 3. Percent of ODCM limit - Gamma 4.13E-01 4.74E-01 3.24E-01 3.95E-01
- Beta I 1.42E-01 1.62E-01 1.11E-01 1.35E-01
- 4. Quarterly Gamma Dose mrad 4.13E-02 4.74E-02 3.24E-02 3.95E-02
- 5. Quarterly Beta Dose mrad 2.84E-02 3.24E-02 2.22E-02 2.69E-02 B. Iodine
- 1. Total iodine- 131 Ci 9.05E-04 7.85E-04 2.10E-03 3.42E-04 1.76E+01
- 2. Average release rate for period pCi/sec 1.15E-04 9.98E-05 2.67E-04 4.35E-05
- 3. Percent of ODCM limit %
C. Particulates
- 1. Particulates with half-lives> 8 days Ci 9.18E-04 5.08E-04 3.17E-04 2.27E-04 1.94E+01
- 2. Average release rate for the period pOCisec 1.17E-04 6.46E-05 4.04E-05 2.89E-05
- 3. Percent of ODCM limit % ....
- 4. Gross alpha radioactivity Ci <LLD <LLD <LLD <LLD D. Tritium
- 1. Total release Ci 6.35E+00 1.06E+01 7.61E+00 8.97E+00 1.11E+01
- 2. Average release rate for the period LpCi/sec 8.08E-01 1.35E+00 9.68E-01 1.14E+00
- 3. Percent of ODCM limit % ....
E. I odi ne 131 & 133 ,Tritiumr& Partic ulate _____________________
- 1. Percent of ODCM limit % 4.28E-021 3.80E-02 1.01E-01 I 1.47E-02
- 2. Quarterly Dose l mrem I 6.42E-03 15.70E-03 I1.52E-02 12.20E-03
- Limit is no longer applicable to iodine and particulate. Section E provides limit.
15
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 2 Gaseous Effluents for Elevated Release Point - Main Stack Period: 2009 Unit: Peach Bottom Units 2 & 3
[NUCLIDES RELEASED
- 1. Fission gases Unit Quarter Quarter J CONTINUOUS MODE ater Qua rterI Quarter BATCH MODE Quarter Quarter Quarter Kr-85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-85m Ci 1.15E+01 1.30E+01 2.93E+01 3.22E+00 <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD 1.39E+00 <LLD <LLD <LLD <LLD <LLD Kr-88 Ci 4.42E+00 9.28E+00 3.80E+01 <LLD <LLD <LLD <LLD <LLD Xe-133 Ci 2.13E+01 1.63E+02 3.73E+01 <LLD <LLD <LLD <LLD <LLD Xe-135 Ci 9.48E+00 2.18E+00 1.15E+00 1.05E+01 <LLD <LLD <LLD <LLD Xe-135m Ci 8.25E+00 8.24E-01 2.83E+00 <LLD <LLD <LLD <LLD <LLD Xe-138 Ci 8.24E+00 1.27E+01 1.22E+01 <LLD <LLD <LLD <LLD <LLD Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ci Unidentified Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 6.32E+01 2.01E+02 1.22E+02 1.37E+01 <LLD <LLD <LLD <LLD
[2. lodines F- ________
11-131 Ci 2.42E-04 1.81 E-04 3.95E-04 1.50E-04 <LLD <LLD <LLD <LLD 1-133 Ci 3.42E-04 5.05E-04 1.49E-03 2.57E-04 <LLD <LLD <LLD <LLD 1-135 Ci <LLD <LLD 1.29E-04 <LLD <LLD <LLD <LLD <LLD Total for Period Ci 5.84E-04 6.86E-04 2.01E-03 4.07E-04 <LLD <LLD <LLD <LLD L. Particulates I-*
Sr-89 Ci 2.39E-041 2.12E-04 1.75E-04 1.25E-04 < LLD <LLD <LLD <LLD Sr-90 Ci 2.19E-07 1.85 E-07 <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <1LLD <LLD <LLD <LLD <LLD <LLD Cs137 Ci <LLD 8.87 E-07 <LLD 9.78E-07 <LLD <LLD <LLD <LLD Ba_-140 Ci 6.34E-04 2.42E-04 1.02E-04 6.72E-05 <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mn-54 Ci <LLD <LI D <LLD 1.68E-06 <LLD <LLD <LLD <LLD Co-58 Ci <LLD <LLD 6.66E-07 <LLD <LLD <LLD <LLD <LLD Co-60 Ci 7.89E-06 1.85E-05 2.34E-05 1.29E-05 <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD AC-1 10M Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD A -203 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD 2.21 E-06 1.97E-06 <LLD <LLD <LLD <LLD <LLD Total for Period Ci 8.81E-04 4.75E-04 3.03E-04 2.08E-04 <LLD <LLD <LLD <LLD 16
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 2 Gaseous Effluents Ground Level Release Point - Unit 2 & 3 Roof Vents & Aux Boiler Stack Period: 2009 Unit: Peach Bottom Units 2 & 3 INuclides Released Continuous Mode II Batch Mode
- 1. Fission gasesJ Unit Quarter Quarter Quarter Quarter i Quarter Quarter1 Quarter Quarter K- 1 Ci_<LLDLLD 2 3
<LD1 i4L 1 <L 3L <L4D Kr-85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-857 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD < LLD <LLD <LLD <LLD Xe-133 Ci <LLD 3.37E+00 <LLD <LLD <LLD <LLD <LLD <LLD Xe-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD < LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ar-41 Ci <LLD <LLD 8.37 E+ 00 <LLD <LLD <LLD <LLD <LLD Ci Unidentified Ci 1.60E+02 1.80E+02 1.19E+02 1.53E+02 <LLD <LLD <LLD <LLD Total for Period Ci 1.60E+02 1.83E+02 1.27E+02 1.53E+02 <LLD <LLD <LLD <LLD
[2._lodines .I 1~ >>>1 1' 1-131 Ci 6.63E-04 6.04E-04 1.70E-03 1.92E-04 <LLD <LLD <LLD <LLD 1-133 Ci 2.83E-03 2.79E-03 3.62E-03 3.60E-04 <LLD <LLD <LLD <LLD 1-135 Ci <LLD <LLD < LLD <LLD <LLD <LLD <LLD <LLD
-TotalforPeriod Ci 3.49E-03 3.39E-03 5.32E-03 5.52E-04 <LLD <LLD <LLD <LLD
- 13. Particulates 11..11 _ __-
5r-89 Ci 3.73E-05 3.27E-05 1.39E-05 1.89E-05 <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs137 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-1 40 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mn-54 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD -<LLD Co-58 Ci <LLD <LLD < LLD <LLD <LLD <LLD <LLD < LLD Co-60 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-1 10m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ci Ci Ci CI Total for Period IC i 13.73E-0513.27E-0511.39E-05M1.89E-05 <LLD <LLD I<LLD <LLD 17
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 2 Liquid Effluents - Summation Of All Releases Period: 2009 Unit: Peach Bottom Units 2 & 3 A. Fission & Activation Products I Unit Quarter Quarter Quarter Quarter EstoTotal 1 1 1 1 2 1 3 4 ror
- 1. Total Release (not including tritium, gases
& alpha) Ci 2.26E-02 3.67E-02 3.28E-02 3.55E-02 2.11E+01
- 2. Average diluted concentration during period ICVmL 1.61E-1 1 1.77E-1 1 1.61E-1 1 1.91E-11
- 3. Percent of ODCM limit -Whole Body % 1.84E-02 2.65E-02 2.33E-02 3.17E-02
-Organ 8.27E-03 1.33E-02 1.08E-02 1.48E-02 B. Tritium
- 1. Total Release Ci 3.13E+00 1.18E+01 1.21E+01 1.10E+01 6.40E+00
- 2. Average diluted concentration during period
_JCvmL 2.23E-09 5.70E-09 5.93E-09 5.90E-09
- 4. Percent of 10CFR 20 limit % 2.23E-04 5.70E-04 5.93E-04 5.90E-04 C. Dissolved & Entrained Gases
- 1. Total Release Ci 4.63E-04 2.42E-03 2.35E-03 4.70E-04 2.11E+01I
- 2. Average diluted concentration during period pCVmL 3.29E-13 1.17E-12 1.15E-12 2.52E-13
- 4. Percent of ODCM limit % 1.65E-07 5.85E-07 5.75E-07 1.26E-07 ID. Gross A] pha Activity I
- 1. Total release Ci I 1.09E-05 1.OOE-051 8.93E-061 1.10E-05l230E+01 E. Volume Of Waste Released (prior to dilution) I Liters 9.43E+071 1.02E+081 1.02E+081 1.01E+081 5.00E+00]
rFVolume Of Dilution Water Used During I Liters I .4e+12l 07E+, l 6.E 2E+O1 18
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 2 Liquid Effluents Release Point - Liquid Radwaste, RHR Leaks & Tritium Leaks Period: 2009 Unit: Peach Bottom Units 2 & 3 INUCLIDES RELEASEDI CONTINUOUS MODE [_ BATCH MODE
- 1. Fission gases Unii Quarter 1 Quarter Quarter I Quarter][ Quarter4 Quarter Quarter Quarter4 Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci 6.61E-05 6.68E-05 5.97E-05 1.21E-04 <LLD <LLD <LLD <LLD Cs-137 Ci 2.04E-04 1.76E-04 1.57E-04 1.47E-04 2.57E-07 3.54E-06 3.51E-06 <LLD 1-131 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-58 Ci 9.88E-05 1.69E-04 1.51 E-04 6.55E-04 <LLD <LLD <LLD <LLD Co-60 Ci 1.59E-02 2.81 E-02 2.51 E-02 2.34E-02 4.48E-04 <LLD <LLD 4.44E-07 Fe-59 Ci 2.43E-04 3.95E-04 3.53E-04 5.18E-04 <LLD <LLD <LLD <LLD Zn-65 Ci 8.88E-04 1.57E-03 1.40E-03 1.86E-03 <LLD <LLD <LLD <LLD Mn-54 Ci 2.73E-03 4.13E-03 3.69E-03 3.96E-03 4.55E-06 <LLD <LLD <LLD Cr-51 Ci 9.72E-04 1.40E-03 1.25E-03 3.75E-03 <LLD <LLD <LLD <LLD Zr-95 Ci <LLD <LLD 5.47E-06 1.68E-05 <LLD <LLD <LLD <LLD Nb-95 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD 5.81 E-06 7.74E-06 7.22E-06 <LLD <LLD <LLD <LLD Tc-99m Ci <LLD 5.94E-06 7.91 E-06 7.38E-06 <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD 6.70E-04 <LLD 1.16E-05 <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-i 1Om Ci <LLD <LLD 5.OOE-05 4.66E-05 <LLD <LLD <LLD <LLD Fe-55 Ci 3.43E-04 2.62E-04 4.07E-04 7.48E-04 <LLD 2.75E-04 <LLD <LLD P-32 Ci 1.16E-05 <LLD <LLD <LLD <LLD <LLD <LLD <LLD Y-91 m Ci 2.39E-05 3.69E-05 3.30E-05 3.08E-05 <LLD <LLD <LLD <LLD Cs-138 Ci 2.12E-05 6.23E-05 3.87E-05 5.19E-05 <LLD <LLD <LLD <LLD Hf-181 Ci 1.59E-05 1.60E-05 1.43E-05 1.34E-05 <LLD <LLD <LLD <LLD Sb-124 Ci <LLD <LLD <LLD 1.21 E-04 <LLD <LLD <LLD <LLD Ci <LLD Ci <LLD Ci <LLD Ci I <LLD Ci <LLD Ci <LLD
- -Ci. <LLD __.___ __ _._-_
Total for Period Ci 2.15E-02 3.64E-02 3.28E-02 3.55E-02 1.12E-03 2.79E-04 1.51E-05 4.44E-07
.... <LLD I Xe-133 Ci <LLD <LLD <LLD <LLD 2.99E-05 2.01E-04 2.49E-04 <LLD Xe-1 35 Ci <LLD <LLD <LLD <LLD 2.88E-04 1.86E-03 1.78E-03 3.26E-05 Kr-85m Ci <LLD <LLD <LLD <LLD <LLD <LLD 1.13E-06 <LLD Kr-88 Ci 2.28E-05 <LLD <LLD 4.67E-05 <LLD <LLD <LLD <LLD Xe-138 Ci 1.22E-04 3.57E-04 3.19E-04 2.97E-04 <LLD <LLD <LLD <LLD Ar-41 Ci <LLD <LLD <LLD 9.34E-05 <LLD <LLD <LLD <LLD Total for Period Ci 1.45E-04 3.57E-04 3.19E-04 4.37E-04 3.18E-04 2.06E-03 2.03E-03 3.26E-05 19
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (page Intentionally Left Blank) 20
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 3 Solid Waste and Irradiated Fuel Shipments 21
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 22
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC A. SOLID WASTE SHIPPED OFF SITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)
- 1. Tvne of Waste units 2009 1Est. error %
a: spent resin, filters, sludges, evaporator bottoms, etc M3 1.26E+02 Ci 1.47E+02 25 b: dry compressible waste, contaminated equipment, etc. M3 1.31 E+03 Ci 4.611E+00 25 c: Irradiated components, control rods, etc. M3 N/A Ci N/A N/A d: Other (describe) oil M3 1.06E+01 I Ci I1.08E-05 25
- 2. Estimate of major nuclide composition (by type of waste) a: spent resin, filters. sludaes, evaporator bottoms.I etc abundance nuclide (no cutoff) activity (Ci)
H-3 0.155% 2.28E-01 C-14 1.040% 1.53E+00 Cr-51 0.000% 9.13E-06 Mn-54 2.747% 4.04E+00 Fe-55 19.647% 2.89E+01 Fe-59 0.000% 2.21E-04 Co-57 0.001% 8.60E-04 Co-58 0.046% 6.77E-02 Co-60 55.951% 8.23E+01 Ni-63 5.126% 7.54E+00 Zn-65 2.651% 3.90E+00 Sr-89 0.001% 1.54E-03 Sr-90 0.107% 1.57E-01 Y-88 0.000% 2.45E-04 Y-93 0.000% 2.47E-51 Zr-95 0.001% 9.35E-04 Nb-95 0.000% 4.42E-06 Mo-99 0.000% 1.86E-47 Tc-99 0.015% 2.14E-02 Ru- 106 0.009% 1.32E-02 Ag-il1in 0.187% 2.75E-01 Sb-124 0.000% 2.84E-04 Sb-125 0.017% 2.56E-02 Te-129m 0.002% 3.03E-03 1-129 0.000% 3.38E-04 1-131 0.000% 6.26E-08 1-135 0.000% 4.80E-52 Xe-131m 0.000% 1.50E-13 Cs- 134 0.748% 1.10E+00 Cs-137 11.217% 1.65E+01 Ba-140 0.000% 3.36E-05 La- 140 0.000% 3.52E-32 Ce-141 0.002% 2.42E-03 Ce-144 0.205% 3.02E-01 Pr-144 0.000% 1.43E-43 Eu-152 0.004% 6.OOE-03 Re-1 88 0.000% 2.66E-87 Pt-191 0.000% 4.09E-45 Hg-203 0.000% 5.03E-06 Pu-238 0.001% 1.13E-03 Pu-239 0.000% 2.18E-04 Pu-241 0.116% 1.71 E-01 Pu-242 0.001% 9.46E-04 Am-241 0.001% 1.08E-03 Cm-242 0.000% 2.06E-04 Cm-243 0.001% 1.24E-03 Cm-244 0003(1%
1.42E-03 0001%
Totals f 100% 1.47E+02 23
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC b: dry compressible waste, contaminated equipment, etc.
abundance nuclide (no cutoff) activity (Ci)
H-3 0.052% 2.38E-03 C-14 0.004% 1.97E-04 Cr-51 0.316% 1.46E-02 Mn-54 7.846% 3.62E-01 Fe-55 32.293% 1.49E+00 Fe-59 0.150% 6.92E-03 Co-58 0.440% 2.03E-02 Co-60 52.752% 2.43E+00 Ni-63 0.606% 2.79E-02 Zn-65 2.731% 1.26E-01 Sr-89 0.000% 1.60E-05 Sr-90 0.001% 4.72E-05 Zr-95 0.002% 9.98E-05 Nb-95 0.070% 3.25E-03 Tc-99 0.000% 3.79E-07 Ag-110m 0.011% 5.05E-04 Cs-134 0.045% 2.08E-03 Cs-137 2.538% 1.17E-01 Ce-141 0.009% 4.27E-04 Ce-144 0.120% 5.52E-03 Pu-238 0.000% 9.06E-06 Pu-241 0.014% 6.58E-04 Cm-242 0.000% 1.50E-05 Cm-243 0.000% 1.20E-05 Totals 100% 4.61 E+00 c: Irradiated components, control rods, etc.
abundance nuclide (no cutoff) activity (Ci)
None for 2009 d: Other (describe) oil abundance nuclide (no cutoff) activity (Ci)
Co-60 50.696% 5.46E-06 Cs-137 5.571% 6.OOE-07 Ce-144 43.733% 4.71 E-06 Totals 100% 1.08E-05
- 3. Solid Waste Disposition Number of shipments Mode of Transportation Destination 27 highway Energy Solutions (Clive, UT) 40 highway Energy Solutions (Oak Ridge, TN)
B. IRRADIATED FUEL SHIPMENTS (Disposition)
No shipment of irradiated fuel were made during the reporting period of 2009.
24
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC C. Changes to Process Control Program (PCP)
There no changes made to RW-AA-1 00 "Process Control Program for Radioactive Waste" in 2009.
25
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 26
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 4 Radiological Impact on Man 27
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 28
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC
- 1. Radiological Impact on Man A summary of gaseous and liquid radiation annual doses to MEMBERS OF THE PUBLIC as calculated by the ODCM follows:
Effluent Applicable Estimated Age Location % of Limit Unit Organ Dose Group Distance Direction Applicable (meters) (toward) Limit Noble Gas Gamma - Air Dose 1.61 E-01 All 1097 SSE 8.05E-01 20 mrad Noble Gas Beta - Air Dose 1.10E-01 All 1097 SSE 2.75E-01 40 mrad Gaseous Total Body 2.62E-01 All 1097 SSE 2.62E+00 10 mrem Gaseous Skin 4.73E-01 All 1097 SSE 1.58E+00 30 mrem
- Iodine, Particulate & Thyroid 2.95E-02 Child 1097 SSE 9.83E-02 30 mrem Tritium Direct Diat Total Body Radiation <LLD All 1150 SSE <LLD 22 mrem Liquid Total Body 3.OOE-03 Adult Site Boundary 5.OOE-02 6 mrem Liver 4.72E-03 Adult Site Boundary 2.36E-02 20 mrem 40 CFR 190 Total Body 1.64E-01 All 1148 SSE 6.56E-01 25 mrem 40 CFR 190 Thyroid 1.95E-01 All 1148 SSE 2.60E-01 75 mrem 40 CFR 190 Other Critical Organ 1.95E-01 All 1148 SSE 7.80E-01 25 mrem 40 CFR 190 Whole Body 1.64E-01 All 1148 SSE 5.47E+00 3.0 mrem 40 CFR 190 Critical Organ 1.95E-01 All 1148 SSE 6.50E+00 3.0 mrem 40 CFR 190 Thyroid 1.95E-01 All 1148 SSE 3.54E-01 55 mrem Doses calculated were well below all ODCM limits.
- 2. 40 CFR 190 Doses The annual dose equivalent to a real individual who is located beyond the SITE BOUNDARY from all urnanium fuel cycle sources within 8 kilometers were well below limits.
- 3. Liquid and Gaseous Effluent Radiation Monitors and Instrumentation No effluent radiation monitors and instrumentation were unavailable for periods beyond the requirements of the ODCM.
29
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 30
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Attachment 5 Meteorological Data 31
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 32
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 7 1 0 0 0 8 NNE 0 7 1 0 0 0 8 NE 4 2 0 0 .0 0 6 ENE 18 4 0 22 E 7 10 0 17 ESE 2 15 0 17 SE 0 9 SSE 0 1 S 0 13 SSW 0 1 SW 0 1 WSW 0 1 W 0 1 WNW 0 2 NW 0 2 NNW 0 7 variable 0 0 Total 31 66 18 1 0 0 116 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stabi lity class: 0 Hours of missing stability measurements in all s tability classes: 2 33
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC '
Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 1 0 0 0 4 NNE 2 2 0 0 0 0 4 NE 2 0 0 0 0 3 0
ENE 7 0 0 0 0 7 0
E 1 0 0 0 0 1 0
ESE 2 0 0 0 0 2 SE 0 3 0 0 0 0 3 SSE 0 4 1 0 0 0 5 S 0 1 3 2 0 0 6 SSW 0 7 4 0 0 0 11 SW 0 3 1 0 0 0 4 WSW 0 3 1 0 0 0 4 W 0 3 4 4 0 0 11 1 7 14 3 0 0 25 NW 0 7 18 5 1 0 31 NNW 0 5 22 2 0 0 29 Variable 0 0 0 0 0 0 0 Total 15 49 69 16 1 0 150 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 34
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 0 7 NNE 1 0 1 NE 3 0 3 ENE 4 0 4 E 4 0 4 ESE 0 0 0 SE 0 0 4 SSE 0 0 1 S 0 0 3 SSW 0 0 5 SW 0 0 2 WSW 0 0 2 W 0 0 6 WNW 0 0 15 NW 0 3 18 0 0 0 21 NNW 0 4 9 3 0 0 16 Variable 0 0 0 0 0 0 0 Total 15 23 44 11 1 0 94 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 35
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 8 45 28 0 0 .0 .81 NNE 27 12 0 0 0 0 39 NE 28 0 0 0 0 0 28 ENE 18 0 0 0 0 0 18 E 24 1 0 0 0 0 25 ESE 10 2 0 0 0 0 12 SE 6 36 10 0 0 0 52 SSE 11 31 15 0 0 0 57 S 12 35 13 0 0 0 60 SSW 6 16 0 0 0 0 22 SW 4 4 4 0 0 0 12 WSW .3 6 2 0 0 0 11 W 1 11 19 3 1 0 35 WNW 2 30 66 17 0 0 115 NW 7 63 118 14 0 0 202 NNW 7 58 45 17 0 0 127 Variable 0 0 0 0 0 0 0 Total 174 350 320 51 1 0 896 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 36
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 13 10 0 23 NNE 13 1 0 14 NE 22 0 0 22 ENE 23 0 0 23 E 32 1 0 33 ESE 35 9 0 44 SE 12 29 1 42 SSE 13 31 1 45 S 14 37 5 56 SSW 13 14 1 28 SW 17 8 4 29 WSW 9 22 5 38 W 20 52 7 83 WNW 24 59 15 101 NW 19 52 13 84 NNW 11 13 1 25 Variable 2 0 0 2 Total 292 338 53 8 1 0 692 Hours of calm in this stability class: 3 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 37
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 1 NNE 2 2 NE 4 4 ENE 4 4 E 13 13 ESE 10 11 SE 8 8 SSE 4 4 S 8 9 SSW 7 7 SW 11 13 WSW 14 27 W 12 20 WNW 8 10 NW 5 5 NNW 6 6 Variable 4 4 Total 121 27 0 0 0 0 148 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 38
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 1 1 1 NNE NE 2 2 ENE 2 2 E 4 4 ESE 3 3 SE 3 5 SSE 1 1 S 3 3 SSW 0 0 SW 4 4 WSW 7 10 W 8 8 WNW 3 3 NW 0 1 NNW 2 2 Variable 3 3 Total 47 6 0 0 0 0 53 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 39
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Extremely Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 NNE 0 0 0 NE 0 0 1 ENE 0 0 5 E 1 0 9 ESE 0 0 8 SE 0 0 5 SSE 0 0 0 S 0 0 4 SSW 0 0 0 SW 0 0 0 WSW 0 0 0 W 0 0 0 WNW 0 0 0 NW 0 0 0 NNW 0 0 0 Variable 0 0 0 Total 1 12 12 7 0 0 32 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 40
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Moderately Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 NNE 0 0 1 NE 0 0 0 ENE 0 0 3 E 0 0 3 ESE 0 0 1 SE 0 0 3 SSE 0 0 1 S 0 0 1 SSW 0 0 0 SW 0 0 0 WSW 0 0 0 W 0 0 0 WNW 0 0 0 0 0 0 NNW 0 0 0 Variable 0 0 0 Total 0 0 14 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 41
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Slightly Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Win .d Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 NNE 0 1 NE 0 2 ENE 1 2 E 0 3 ESE 0 1 SE 0 0 SSE 0 0 S 0 0 SSW 0 0 SW 0 0 WSW 0 0 W. 0 0 WNW 0 0 NW 0 0 NNW 0 0 Variable 0 0 Total 1 10 19 20 5 7 62 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 2 42
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Neutral - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 12 59 43 11 2 131 NNE 21 14 3 0 0 40 NE 17 11 0 0 0 36 ENE 25 15 0 0 0 49 E 14 17 2 0 0 41 ESE 11 30 11 0 0 55 SE 14 30 15 0 0 62 SSE 9 30 16 1 0 57 S 4 35 18 8 0 66 SSW 2 13 3 1 0 19 SW 4 7 5 0 0 18 WSW 2 4 4 0 2 15 W 1 9 10 25 26 71 WNW 5 10 48 57 36 156 NW 5 24 103 61 12 206 NNW 13 45 85 28 12 185 Variable 0 0 0 0 0 1 Total 48 159 353 366 192 90 1208 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 33 Hours of missing stability measurements in all stability classes: 2 43
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Slightly Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 22 6 0 0 31 NNE 1 6 3 1 0 0 11 NE 5 13 0 1 0 0 19 ENE 4 9 7 0 0 20 E 1 7 17 6 0 31 ESE 1 5 16 4 0 26 SE 2 6 16 15 0 39 SSE 0 4 30 19 0 53 S 4 19 47 25 0 99 SSW 1 9 15 10 0 36 SW 4 10 16 2 0 38 WSW 4 2 5 8 3 27 W 0 5 5 12 2 26 WNW 2 1 10 31 5 0 .49 NW 0 8 24 28 3 0 63 NNW 0 3 16 15 0 0 34 Variable 0 0 0 0 0 0 0 Total 29 110 249 183 26 5 602 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 46 Hours of missing stability measurements in all stability classes: 2 44
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Moderately Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 NNE 5 NE 2 ENE 5 E 1 ESE 4 SE 15 SSE 10 S 10 SSW 18 SW 17 WSW 12 W 7 WNW 4 NW 5 NNW 2 Variable 0 Total 12 41 43 20 3 0 119 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 9 Hours of missing stability measurements in all stability classes: 2 45
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: January - March 2009 Stability Class - Extremely Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24. Total N 0 NNE 0 NE 0 ENE 1 E 0 ESE 0 SE 0 SSE 0 S 2 SSW 1 SW 7 WSW 14 W 4 WNW 0 NW 2 NNW 1 Variable 0 Total 2 10 11 7 2 0 32 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 46
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Extremely Unstable - 15OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 11 4 0 0 0 20 NNE 4 2 0 0 0 0 6 NE 9 3 0 0 0 0 12 ENE 19 3 0 0 0 0 22 E 17 6 0 0 0 0 23 ESE 12 6 0 0 0 0 18 SE 6 33 0 0 0 0 39 SSE 4 20 2 0 0 0 26 S 2 19 9 0 0 0 30 SSW 1 5 4 0 0 0 10 SW 0 6 7 0 0 0 13 WSW 0 3 7 0 0 0 10 W 1 9 15 0 0 0 25 WNW 0 11 13 7 0 0 31 NW 0 6 6 0 0 0 12 NNW 0 31 9 1 0 0 41 Variable 0 0 0 0 0 0 0 Total 80 174 76 8 0 0 338 Hours of calm in this stability class:. 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 47
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Moderately Unstable .- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 9 1 0 0 0 14 NNE 8 0 0 0 0 0 8 NE 6 0 0 0 0 0 6 ENE 8 0 0 0 0 0 8 E 11 1 0 0 0 0 12 ESE 3 1 1 0 0 0 5 SE 4 11 0 0 0 0 15 SSE 5 8 0 0 0 0 13 S 4 7 0 0 0 12 SSW 1 3 1 0 0 0 5 SW 1 5 2 0 0 0 8 WSW 1 3 4 0 0 0 8 1 6 4 0 0 12 W 1 WNW 0 1 2 2 0 0 5 NW 0 6 2 0 0 0 8 NNW 2 13 4 0 0 0 19 Variable 0 0 0 0 0 0 0 Total 59 74 21 4 0 0 1158 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 48
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 8 NNE 0 4 NE 0 0 ENE 0 2 E 0 4 ESE 0 0 SE 0 4 SSE 0 10 S 0 7 SSW 0 2 SW 0 4 WSW 0 2 W 0 3 WNW 0 2 NW 0 3 NNW 2 8 0 0 0 0 10 Variable 0 0 0 0 0 0 0 Total 26 31 7 1 0 0 65 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stabi lity class: 0 Hours of missing stability measurements in all s tability classes: 7 49
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18. 19-24 > 24 Total N 23 48 13 84 NNE 27 27 0 54 NE 26 3 0 29 ENE 20 0 0 20 E 15 9 0 24 ESE 17 8 0 25 SE 27 40 11 78 SSE 32 43 10 85 S 17 39 15 71 SSW 10 9 1 20 SW 5 9 4 18 WSW 2 9 2 14 W 6 17 13 42 WNW 7 11 22 40 NW 11 25 8 44 NNW 15 45 26 86 Variable 2 0 0 2 Total 262 342 125 7 0 0 736
.Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 50
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 24 20 1 0 0 45 NNE 8 4 0 0 0 12 NE 14 1 0 0 0 15 ENE 11 0 0 0 0 11 E 21 5 0 0 0 26 ESE 19 6 0 0 0 25 SE 17 7 1 0 0 25 SSE 50 19 0 0 0 69 S 25 21 2 0 0 48 SSW 17 14 0 0 0 31 SW 21 16 0 0 0 37 WSW 13 25 0 0 0 38 W 21 21 2 0 0 44 WNW 25 39 2 0 0 66 NW 29 46 1 0 0 76 NNW 33 27 0 0 0 60 Variable 0 0 0 0 0 0 Total 348 271 9 0 0 0 628 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stabili ty class: 0 Hours of missing stability measurements in all sta bility classes: 7 51
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 1 NNE 2 0 2 NE 3 0 3 ENE 2 0 2 E 3 0 3 ESE 6 0 6 SE 9 0 9 SSE 16 0 16 S 6 0 6 SSW 9 0 9 SW 18 5 23 WSW 18 i0 28 W 21 6 27 WNW 14 5 19 NW 5 1 6 NNW 5 0 5 Variable 0 0 0 Total 138 27 0 0 0 0 165 Hours of calm in this stability class: 2 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 52
Facility: Peach Bottom Units 2 & 3 Licensee: Exeloh Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 1 NNE 0 1 1
NE 0 0 0 ENE 0 0 0 E 3 0 3 ESE 1 0 1 SE 0 0 0 SSE 0 0 0 S 1 0 1 SSW 6 0 6 SW 13 0 18 WSW 23 4 0 0 0 0 27 W 15 1 0 0 0 0 16 WNW 2 0 0 0 0 0 2 NW 1 0 0 0 0 0 1 NNW 1 0 0 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 68 10 0 0 0 0 78 Hours of calm in this stability class: 3 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all. stability classes: 7 53
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Extremely Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 NNE 0 0 NE 2 5 ENE 0 5 E 6 13 ESE 11 21 SE 4 7 SSE 4 5 S 2 3 SSW 0 1 SW 0 0 WSW 0 2 W 3 5 WNW 0 1 NW 0 0 NNW 2 3 Variable 0 0 Total 0 22 34 15 0 0 71 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 54
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Moderately Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 0 0 0 0 3 NNE 0 3 0 0 0 0 3 NE 0 2 0 0 0 0 2 ENE 1 5 0 0 0 0 6 E 1 7 0 0 0 0 8 ESE 0 3 2 0 0 0 5 SE 0 1 9 2 0 0 12 SSE 0 0 5 0 0 0 5 S 0 0 7 6 0 0 13 SSW 0 0 3 0 0 0 3 SW 0 0 1 1 0 0 2 WSW 0 1 2 2 0 0 5 W 0 0 2 2 3 3 10 WNW 0 0 3 0 7 3 13 NW 0 0 1 3 0 6 NNW 0 0 1 3 0 0 4 Variable 0 0 0 0 0 0 0 Total 2 25 36 18 13 6 100 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 55
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Slightly Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 1 2 0 0 4 NNE 0 1 0 0 0 0 1 NE 1 4 0 0 0 0 5 ENE 1 2 0 0 0 0 3 E 0 1 1 0 1 0 3 ESE 0 3 2 1 0 0 6 SE 0 1 4 1 0 0 6 SSE 0 0 3 2 0 0 5 S 0 2 4 2 0 0 8 SSW 0 0 4 2 0 0 6 SW 0 0 2 7 1 0 10 WSW 0 0 1 2 3 0 6 W 0 0 3 3 5 1 12 WNW 0 0 2 2 5 1 10 NW 0 1 2 4 2 0 9 NNW 0 5 14 3 1 0 23 Variable 0 0 0 0 0 0 0 Total 2 21 43 31 18 2 117 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 56
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Neutral - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 11 24 24 10 1 70 NNE 4 7 24 19 1 0 55 NE 4 11 25 11 2 0 53 ENE 5 12 30 4 0 0 51 E 7 25 35 28 10 2 107 ESE 5 11 34 44 9 0 103 SE 4 7 31 27 10 0 79 SSE 0 10 28 18 1 0 57 S 0 15 25 36 10 2 88 SSW 0 9 14 5 0 0 28 SW 1 7 12 13 2 0 35 WSW 1 3 11 9 6 3 33 W 0 5 12 17 16 12 62 WNW 1 4 10 16 19 4 54 NW 2 14 22 29 9 0 76 NNW 1 14 33 40 6 0 94 Variable 0 0 0 0 0 0 0 Total 35 165 370 340 ill 24 1045 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 57
Facility: Peach Bottom Units 2 & 3 Licensee:* Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Slightly Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 9 24 6 0 39 NNE 11 8 1 0 20 NE 6 5 0 0 13 ENE 9 5 2 0 17 E 18 5 1 0 27 ESE 15 11 8 9 47 SE 12 15 6 0 35 SSE .12 20 4 0 43 S 24 28 18 7 80 SSW 12 27 1.3 0 55 SW 17 18 12 1 51 WSW 5 10 18 2 37 W 2 14 19 2 38 WNW 4 14 20 8 47 NW 2 18 33 15 69 NNW 5 21 17 2 47 Variable 0 0 0 0 0 Total 34 163 243 178 46 1 665 Hours of calm in this stability class.: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 58
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: April - June 2009 Stability Class - Moderately Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 1 0 0 0 0 2 NNE 3 2 0 0. 0 0 5 NE 0 2 0 0 0 0 2 ENE 0 0 0 0 0 0 0 E 0 2 0 0 0 0 2 ESE 0 0 0 0 0 0 0 SE 2 0 0 0 0 0 2 SSE 0 2 2 0 0 0 4 S 1 6 5 3 1 0 16 SSW 0 7 5 3 0 0 15 SW 2 7 11 2 0 0 22 WSW 1 6 6 6 0 0 19 W 0 2 1 5 0 0 8 WNW 0 6 7 2 0 0 15 NW 0 4 6 1 0 0 11 NNW 1 2 1 0 0 0 4 Variable 0 0 0 0 0 0 0 Total 11 49 44 22 1 0 127 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 59
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record:. April - June 2009 Stability Class -. Extremely Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 0 0 2 NNE 4 1 0 7 NE 0 0 0 2 ENE 0 0 0 1 E 0 0 0 2 ESE 0 0 0 0 SE 0 0 0 0 SSE 0 0 0 0 S 2 1 0 5 SSW 0 1 0 1 SW 2 0 0 2 WSW 1 2 1 4 W 1 2 0 4 WNW 4 5 1 11 NW 0 6 2 8 NNW 0 3 0 3 variable 0 0 0 0 Total 11 16 21 4 0 0 52 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 7 60
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 9 24 0 0 33 NNE 16 6 0 0 22 NE 26 0 0 0 26 ENE 21 0 0 0 21 E 13 0 0 0 13 ESE 20 1 0 0 21 SE 14 13 0 0 27 SSE 4 30 7 0 41 S 1 29 4 0 34 SSW 1 10 0 0 11 SW 0 3 0 0 3 WSW 1 3 0 0 4 W 1 6 1 0 8 WNW 2 8 0 0 10 NW 2 5 0 0 7 NNW 7 28 0 0 35 Variable 1 0 0 0 1 Total 139 166 12 0 0 0 317 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 61
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 7 20 0 28 NNE 8 4 0 12 NE 5 0 0 5 ENE 2 0 0 2 E 4 0 0 4 ESE 2 0 0 2 SE 1 1 0 2 SSE 2 11 0 13 S 2 5 0 7 SSW 0 6 0 6 SW 3 3 0 6 WSW 3 4 0 8 W 2 10 1 0 0 0 13 WNW 3 8 3 0 0 0 14 5 9 0 0 0 0 14 NNW 5 22 0 0 0 0 27 Variable 1 0 0 0 0 0 1 Total 55 103 6 0 0 0 164 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stabi lity classes: 11 62
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 5 0 0 11 NNE 2 0 0 0 2 NE 4 0 0 0 4 ENE 2 0 0 0 2 E 0 0 0 0 0 ESE 1 0 0 0 1 SE 1 1 0 0 2 SSE 2 2 1 0 5 S 1 3 0 0 4 SSW 0 1 0 0 1 0 1 SW 1 0 0 WSW 2 3 1 0 6 W 1 2 0 0 3 WNW 2 4 1 0 7 NW 2 6 0 0 8 NNW 2 0 9 Variable 0 0 0 Total 29 34 3 0 0 0 66 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 63
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 32 21 0 0 0 0 53 NNE 16 3 0 0 0 0 19 NE 4 0 0 0 0 0 4 ENE 11 0 0 0 0 0 11 E 1 0 0 0 0 0 1 ESE 8 1 0 0 0 0 9 SE 21 6 0 0 0 0 27 SSE 14 41 0 0 0 0 55 S 19 16 0 0 0 0 35 SSW 13 5 0 0 0 0 18 SW 12 4 2 0 0 0 18 WSW 8 14 2 0 0 0 24 W 13 15 5 0 0 0 33 WNW 15 19 0 0 0 0 34 NW 21 21 4 0 0 0 46 NNW 23 44 5 0 0 0 72 Variable 1 0 0 0 0 0 1 Total 232 210 18 0 0 0 460 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 64
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 37 25 0 65 NNE 9 1 0 10 NE 5 0 0 5 ENE 2 0 0 2 E 5 0 0 5 ESE 13 0 0 13 SE 33 12 0 45 SSE 45 44 0 89 S 32 21 0 53 SSW 20 5 0 26 SW 26 9 0 35 WSW 34 28 0 62 W 40 24 0 64 WNW 53 39 0 92 NW 46 41 0 87 NNW 38 29 0 73 Variable 3 0 0 3 Total 441 278 10 0 0 0 729 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 65
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Moderately Stable . - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 0 3 NNE 1 0 1 NE 2 0 2 ENE 0 0 0 E 1 0 1 ESE 1 0 1 SE 3 0 3 SSE 3 0 3 S 5 0 5 SSW 10 0 11 SW 37 2 0 0 0 0 39 WSW 54 20 0 0 0 0 74 W 57 19 0 0 0 0 76 WNW 37 15 0 0 0 0 52 NW 19 5 0 0 0 0 24 NNW 8 0 0 0 0 0 8 Variable 1 0 0 0 0 0 1 Total 242 62 0 0 0 0 304 Hours of calm in this stability class: 2 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 66
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Extremely Stable - 15OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 .8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 NNE 0 0 0 0 0 NE 0 0 0 0 0 ENE 0 0 0 0 0 E 0 0 0 0 0 ESE 0 0 0 0 0 SE 0 0 0 0 0 SSE 0 0 0 0 0 S 0 0 0 0 0 SSW 2 0 0 0 2 SW 43 16 0 0 0 0 59 WSW 55 7 0 0 0 0 62 W 17 3 0 0 0 0 20 WNW 8 1 0 0 0 0 9 NW 2 0 0 0 0 0 2 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 127 27 0 0 0 0 154 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stabi lity class: 0 Hours of missing stability measurements in all s tability classes: 11 67
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Extremely Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 NNE 0 0 0 NE 0 1 1 ENE 13 4 17 E 15 5 20 ESE 5 10 16 SE 1 3 4 SSE 0 2 3 S 0 2 4 SSW 0 0 0 SW 0 1 1 WSW 0 0 0 W 0 0 0 WNW 0 0 0 NW 0 0 0 NNW 0 0 0 Variable 0 0 0 Total 0 34 28 4 0 0 66 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 68
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Moderately Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 1 0 0 0 2 NNE 0 3 3 0 0 0 6 NE 1 3 3 2 0 0 9 ENE 1 10 0 0 0 0 11 E 8 0 0 0 0 9 ESE 1 5 0 3 0 0 9 SE 0 4 5 0 0 0 9 SSE 0 1 7 3 0 0 11 S 0 3 5 3 3 0 14 SSW 0 1 1 0 0 0 2 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 1 1 W 0 0 0 0 0 0 0 0 0 0 1 0 0 1 NW 0 0 1 0 0 0 NNW 0 0 3 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 4 39 29 12 3 1 88 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 69
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Slightly Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 4 0 0 0 7 NNE 2 7 3 2 0 0 14 NE 2 3 1 0 0 0 6 ENE 4 8 1 2 0 0 15 E 0 6 0 1 0 0 7 ESE 0 2 2 0 0 0 4 SE 0 4 5 1 0 0 10 SSE 0 0 2 1 0 0 3 S 0 2 12 4 0 0 18 SSW 0 0 4 2 0 0 6 SW 0 1 1 0 0 0 2 WSW 0 1 1 1 0 0 3 W 0 1 0 6 1 0 8 WNW 0 1 2 4 0 0 7 NW 0 1 6 3 0 0 10 NNW 0 2 10 1 0 0 13 Variable 0 0 0 0 0 0 0 Total 8 42 54 28 1 0 133 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 70
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class -,:Neutral - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 16 16 7 48 NNE 9 17 17 9 52 NE 10 20 19 7 57 ENE 8 25 23 6 62 E 6 20 23 5 56 ESE 6 18 22 10 56 SE 2 7 14 14 37 SSE 3 7 15 10 35 S 1 11 21 13 46 SSW 1 9 9 5 24 SW 2 12 13 1 30 WSW 0 6 13 10 35 W 2 5 21 19 52 WNW 4 11 20 15 51 NW 2 17 37 18 77 NNW 5 24 46 8 90 Variable 0 0 0 0 0 Total 65 225 329 157 30 2 808 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 71
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Slightly Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 16 24 11 2 0 54 NNE 3 8 7 4 0 0 22 NE 2 11 16 3 0 0 32 ENE 3 20 9 2 0 0 I34 E 3 11 11 0 0 0 25 ESE 5 13 17 1 0 0 36 SE 2 18 14 2 0 0 36 SSE 3 18 28 11 0 0 60 S 3 14 33 25 0 0 75 SSW 6 10 21 5 0 1 43 9 15 13 1 0 42 SW 4 0 6 16 20 1 0 43 WSW W 1 3 13 25 1 0 43 WNW 3 6 23 31 2 0 65 NW 3 10 35 50 4 0 102 0 7 37 19 2 0 65 Variable 0 0 0 0 0 0 0 Total 42 180 319 222 13 1 777 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 72
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Moderately Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 9 15 NNE 1 5 NE 0 5 ENE 0 6 E 0 3 ESE 0 3 SE 1 9 SSE 0 9 S 0 12 SSW 7 22 SW 9 20 WSW 6 18 W 14 29 WNW 7 23 NNW 14 31 NNV 17 34 Variable 0 0 Total 29 80 85 50 0 0 244 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 73
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: July - September 2009 Stability Class - Extremely Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 6 10 0 19 NNE 0 0 3 NE 0 5 ENE 0 2 E 0 0 ESE 0 1 SE 0 1 SSE 0 0 S 0 1 SSW 0 3 SW 0 4 WSW 0 2 W 0 5 WNW 0 7 NW 0 4 NNW 8 14 0 22 Variable 0 0 0 0 Total 16 26 31 6 0 0 79 Hours of calm in this stability class: 2 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 11 74
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 0 8 NNE 7 0 9 NE 8 0 9 ENE 4 0 4 E 10 0 10 ESE 5 0 7 SE 0 0 6 SSE 0 0 2 S 0 0 8 SSW 0 0 2 SW 0 0 0 WSW 0 0 1 W 0 0 4 WNW 0 0 8 NW 0 0 8 NNW 0 0 8 Variable 0 0 0 Total 36 48 10 0 0 0 94 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 7 75
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 6 NNE 10 0 12 NE 4 0 4 ENE 7 0 7.
E 2 0 3 ESE 2 0 2 SE 0 0 3 SSE 0 0 4 S 0 0 3 SSW 0 0 1 SW 0 0 2 WSW 2 0 5 W 3 6 11 2 0 0 22 WNW 0 11 18 2 0 0 31 NW 1 9 15 2 1 0 28 NNW 1 10 6 2 0 0 19 Variable 0 0 0 0 0 0 0 Total 33 54 56 8 1 0 152 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 76
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom ITuclear Station Period of Record: C)ctober - December 2009 Stability Class - Slightly Ur istable - 15OFt-33Ft Delta-T (F)
Winds Measui :ed at 33 Feet WincI Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 5 1 9 NNE 2 0 0 2 NE 3 0 0 3 ENE 2 0 0 2 E 3 0 0 3 ESE 1 1 0 2 SE 2 0 0 2 SSE 0 2 3 5 S 0 1 1 2 SSW 0 0 0 0 SW 0 0 0 0 WSW 0 1 1 2 W 0 5 2 7 WNW 1 3 4 9 NW 0 6 2 10 NNW 1 6 1 8 Variable 0 0 0 0 Total 18 30 15 3 0 0 66 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 77
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom ITuclear Station Period of Record: C)ctober - December 2009 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)
Winds Measua red at 33 Feet Win(I Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 18 57 22 0 97 NNE 27 43 16 0 86 NE 22 0 0 0 22.
ENE 12 0 0 0 12 E 12 0 0 0 12 ESE 6 0 0 0 6 SE 10 13 2 0 25 SSE 7 36 5 0 48 S 8 23 11 2 44 SSW 0 4 1 0 5 SW 5 4 0 0 9 WSW 4 6 2 0 12 W 3 23 29 1 56 WNW 5 35 55 4 99 NW 6 52 50 11 119 NNW 17 49 22 0 88 Variable 1 0 0 0 1 Total 163 345 215 18 0 0 741 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 78
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 26 26 10 62 NNE 29 20 8 57 NE 41 2 0 43 ENE 34 0 0 34 E 29 2 0 31 ESE 20 7 1 28 SE 18 17 4 39 SSE 18 33 4 55 S 22 7 3 32 SSW 14 11 0 26 SW 17 10 0 28 WSW 22 24 0 46 W 22 72 1 95 WNW 15 75 6 96 NW 28 46 10 84 NNW 22 33 5 60 Variable 1 0 0 1 Total 378 385 52 2 0 0 817 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 79
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - Decei ber 2009 Stability Class - Moderately Stable - 15 OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph l)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 0 4 NNE 3 0 3 NE 8 0 8 ENE 8 0 8 E 8 0 8 ESE 9 0 9 SE 6 1 7 SSE 0 0 0 S 4 0 4 SSW 7 0 7 SW 27 0 27 WSW 18 10 28 W 16 9 25 WNW 21 5 26 NW 20 3 23 NNW 8 0 8 Variable 0 0 0 Total 167 28 0 0 0 0 195 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 80
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Extremely Stable - 15OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 0 0 0 2 NNE 0 0 0 0 0 NE 1 0 0 0 1 ENE 2 0 0 0 2 E 7 0 0 0 7 ESE 2 0 0 0 2 SE 4 0 0 0 4 SSE 1 0 0 0 1 S 2 0 0 0 2 SSW 6 0 0 0 6 SW 23 2 0 0 25 WSW 34 8 0 0 0 0 42 W 16 4 0 0 0 0 20 WNW 7 1 0 0 0 0 8 NW 4 1 0 0 0 0 5 NNW 3 0 0 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 114 16 0 0 0 0 130 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 81
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Extremely Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 NNE 0 0 1 NE 0 0 1 ENE 0 0 2 E 0 0 4 ESE 0 0 10 SE 0 0 0 SSE 0 0 1 S 0 0 4 SSW 0 0 2 SW 0 0 0 WSW 0 0 0 W 0 0 5 WNW 1 0 0 NW 0 1 0
NNW 0 0 0 Variable 0 0 0 Total 0 12 14 6 0 0 32 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 82
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Moderately Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 2 1 0 0 0 3 NE 0 4 4 1. 0 0 9 ENE 0 2 0 0 0 0 2 E 0 0 0 0 0 0 0 ESE 0 4 0 0 0 0 4 SE 0 1 3 1 0 0 5 SSE 0 1 0 1 0 0 .2 S 0 0 2 1 0 0 3 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0. 0 1 0 0 1 W 0 0 2 1 0 0 3 WNW 0 0 0 3 0 0 3 NW 0 0 5 2 0 0 7 NNW 0 0 1 0 0 0 1 Variable 0 0 0 0 0 0 0 Total 0 14 18 11 0 0 43 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 83
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Slightly Unstable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 3 NNE 1 0 5 NE 1 0 4 ENE 0 0 6 E 1 0 6 ESE 0 0 1 SE 0 0 6 SSE 0 0 2 S 0 0 4 SSW 0 0 2 SW 0 0 1 WSW 0 0 4 W 0 5 25 WNW 0 1 4 9 6 1 21 NW 0 2 10 9 1 0 22 NNW 0 0 5 2 0 0 7 Variable 0 0 0 0 0 0 0 Total 3 21 39 34 16 6 119 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 84
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Neutral - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 19 31 19 16 0 87 NNE 1 8 19 42 39 5 114 NE 1 10 31 20 3 1 66 ENE 6 15 26 0 0 0 47 E 6 14 18 2 1 0 41 ESE 1 11 14 1 5 1 33 SE 1 18 19 6 2 4 50 SSE 3 4 29 18 3 0 57 S 1 9 19 15 9 4 57 SSW 0 3 4 5 0 1 13 SW 1 3 6 5 0 1 16 WSW 0 4 6 3 6 3 22 W 1 6 10 42 29 22 110 WNW1 6 14 70 34 19 144 NW 0 3 25 72 29 13 142 NNW 2 6 28 25 18 0 79 Variable 0 0 0 0 0 0 0 Total 27 139 299 345 194 74 1078 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 85
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Slightly Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 9 29 3 0 41 NNE 1 6 8 5 6 26
- NE 2 3 5 3 2 15 ENE 5 14 9 2 0 30 E 5 6 18 22 12 68 ESE 0 15 14 6 5 40 SE 2 11 11 5 1 30 SSE 1 11 17 15 0 44 S 2 5 16 10 1 34 SSW 0 7 10 4 2 23 SW 3 8 12 10 0 33 WSW 1 11 10 19 1 42 W 1 4 14 44 5 68 WNW 0 4 17 36 17 74 NW 0 6 22 31 5 64 NNW 2 6 20 7 4 39 Variable 0 1 0 0 0 1 Total 25 127 232 222 61 5 672 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 86
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Moderately Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph) wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 2 0 0 0 0 4 NNE 0 4 0 0 0 0 4 NE 2 1 2 0 0 0 5 ENE 0 2 1 0 0 0 3 E 0 2 1 0 0 0 3 ESE 0 5 0 0 0 0 5 SE 0 6 3 0 0 0 9 SSE 2 4 3 1 0 0 10 S 1 4 10 1 0 0 16 SSW 1 13 6 0 0 0 20 SW 0 8 5 4 0 0 17 WSW 2 1 11 0 0 0 14 W 1 3 2 9 1 0 16 WNW 0 3 8 14 0 0 .25 NW 2 1 8 3 1 0 15 NNW 1 4 8 1 0 0 14 Variable 0 0 0 0 0 0 0 Total 14 63 68 33 2 0 180 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 87
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Peach Bottom Nuclear Station Period of Record: October - December 2009 Stability Class - Extremely Stable - 316Ft-33Ft Delta-T (F)
Winds Measured at 320 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 NNE 3 NE 4 ENE 0 E 1 ESE 1 SE 4 SSE 2 S 4 SSW 12 SW 11 WSW 1 W 3 WNW 13 NW 7 NNW 5 Variable 0 Total 4 42 29 2 0 0 77 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 7 88
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Appendix A- ERRATA Data Section 89
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 90
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC Appendix B- Revised Copy of the ODCM 91
Facility: Peach Bottom Units 2 & 3 Licensee: Exelon Generation Company, LLC PSEG Nuclear, LLC (Page Intentionally Left Blank) 92