Final Status Survey Release Record Central Peninsula Survey Unit 9530-0004
ML063540287
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/26/2006
From: Mccarthy J
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
Download: ML063540287 (151)


Text

CYAPCO FINAL STATUS SURVEY RELEASE RECORD CENTRAL PENINSULA SURVEY UNIT 9530-0004 Prepared By:

FSS Enginedr Reviewed B SS Engine r Approved By:

4' J,

Technical Support Manager Date: I-o(,

Date:1' Date:

66*/1 Revision 0

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION......................................................

3

2.

CLASSIFICATION BASIS................................................................

3

3.

DATA QUALITY OBJECTIVES (DQO)..........................................

5

4.

SUR V EY D ESIGN.............................................................................

8

5.

SURVEY IMPLEMENTATION.......................................................

11

6.

SURV EY RESULTS.........................................................................

12

7.

QUALITY CONTROL....................................................................

15

8.

INVESTIGATIONS AND RESULTS..............................................

15

9.

REMEDIATION AND RESULTS...................................................

16

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......

16

11. DATA QUALITY ASSESSMENT (DQA)......................................

16

12. A N O M A L IE S....................................................................................

17

13. C O N C LU SIO N..................................................................................

17

14. A TTA CH M EN TS.............................................................................

18 14.1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (5 pages including cover) 14.3 Attachment 3 -Laboratory Data (108 pages including cover) 14.4 Attachment 4 - DQA Results (14 pages including covers)

TOTAL 151 Revision 0

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9530-0004 (Central Peninsula) is designated as Final Status Survey (FSS) Class 3 and consists of 83,777 m2 (21 acres) of uninhabited open land located approximately 2,100 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded as follows: land Survey Unit 9520-0003 to the north (called north as oriented with the north to south flow of the Connecticut River), the Discharge Canal to the east, land Survey Unit 9531-0000 to the south, and the Connecticut River to the west. The survey unit is relatively level open space in the middle of the peninsula.

The restoration of the peninsula for FSS has removed some surface interference in the survey unit.

The reference coordinates associated with this survey unit are E007 through E029 by S095 through S131 (refer to License Termination Plan (LTP) Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit.

The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9530-0004 as Class 3 in September 2006.

The "Classification Basis Summary" conducted for Survey Unit 9530-0004 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

A review of the 10CFR50.75(g)(1) database report identified two documents associated with this survey unit.

a) Northeast Utilities Radiological Assessment Branch memo NE-86-RA-1142: Relates to dredging of two areas of the Discharge Canal to support the Low Pressure Turbine replacement project. Spoils from dredging were relocated to this survey unit and adjacent survey unit 9530-0002.

b) Plant Information Report (PIR) 89-35 and related surveys: Documents the discovery of radioactive spoils that were deposited on the peninsula in 1989 following removal from the outfall area outside the Revision 0 3

Revision 0 3

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Radiologically Controlled Area (RCA). Once identified, the spoils were removed according to the surveys.

c) Condition Report (CR) 06-0089: Documents the discovery of a buried drum containing radioactive material in Survey Unit 9530-0004.

The materials were removed from the peninsula.

A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" was performed.

Survey Unit 9530-0004 was initially designated as Class 3 during the development of the LTP.

The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP revision 0 (references 2-2 and 2-7 respectively). The second source document justified a Class 2 designation for those areas for which there was historical evidence of contamination above the Derived Concentration Guideline Levels (DCGLs -

refer to Section 2 for definition and description of DCGL), but for which recent surveys had shown that decontamination efforts had occurred and that the radiological conditions were expected to be below the DCGLs. Additional justification for a Class 3 designation based on survey and sampling data was provided as another reference to the LTP by the "Haddam Neck Plant Historical Site Assessment Supplement".

The survey unit had undergone FSS in the fall of 2004 and release records documenting the satisfactory completion of the FSS objectives were in preparation.

In 2006, utilities were being removed as part of the decommissioning effort on the Upper Peninsula.

Construction debris including Asbestos Containing Material (ACM) was identified and remediated. In addition to the ACM, several objects were also identified that had detectable radioactivity. Two pieces of angle iron were located in a water utility trench in Survey Unit 9530-0004. Based on the potential to change the final radiological status of the survey unit, another FSS was considered prudent to define the as-left radiological condition.

Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil. Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria.

Therefore, the previous FSS data and statistical parameters were used for the survey design.

Statistical quantities from the previous FSS survey are provided in Table 1.

Revision 0 4

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Table I Basic Stutistical Quantities for*Cs137 from the previous FSSS Minimum Observed Concentration (pCi/g):

O.OOE+00 Maximum Observed Concentration (pCi/g):

3.59E-01 Mean (pCi/g):

1.35E-01 Median (pCi/g):

1.27E-01 Standard Deviation (pCi/g):

8.79E-02 The FSS Engineer performed a visual inspection and walk-down during August 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the previous FSS survey and sampling and the results of radiological surveys performed during the radiological assessment, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit justifying a final survey unit classification of Class 3 (refer to Section 3).

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit does satisfy the primary objective of the FSS plan.

The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9530-0004 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

Revision 0 5

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1 Hvotal = Hsoil + H ExistingGW + HFutureGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024).

Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.

Equation 2 19 mrem/yrTotaj = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 mrem/yrFutureGW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Revision 0 6

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

C-14 5.66E+00 3.85E+00 2.26E-0 I Mn-54 1.74E+01 I. 18E+01 6.96E-0 I Fe-55 2.74E+04 1.86E+04

1. 1 OE+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag-I 08m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.0]E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+O1 1.75E+01 1.03E+00 Cm-243/244 2.90E+O1 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard-to-Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to 1 mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses are performed Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil.

Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for Revision 0 7

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD exceeding the screening criteria.

The previous FSS data and statistical parameters were used for the survey design and are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical

method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".

The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that Cs-137 would be the radionuclide of concern in survey unit 9530-0004 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.

Surrogate DCGLs were not required for this survey unit based the previous FSS of this survey unit and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".

Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 3 area and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 5.2 to maintain the relative shift (A/c) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package Revision 0 8

Revision 0 8

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing and three (3) samples at biased locations.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."

Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A simple random grid pattern was selected for sample design, which is appropriate for a Class 3 area.

Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

KTaIble 3 - Sam1ple Measurirnent Locatio With As'sociated G IPS Coordiniates Liesignatign

~

Nprihing E1'asting 9530-0004-OOIF 235541.47 670598.82 9530-0004-002F 234944.02 671206.69 9530-0004-003F 235686.66 670461.14 9530-0004-004F 235460.41 670198.49 9530-0004-005F 235117.37 671475.79 9530-0004-006F 235060.02 671089.08 9530-0004-007F 235098.53 671618.08 9530-0004-008F 235647.77 670439.26 9530-0004-009F 235495.35 670286.78 9530-0004-OIOF 234781.85 671612.51 9530-0004-01 IF 235349.12 671394.90 9530-0004-012F 235334.80 671690.05 9530-0004-013F 235377.04 670495.72 9530-0004-014F 235151.08 670679.98 9530-0004-015F 234980.04 671035.21 9530-0004-016F 235393.38 670801.87 9530-0004-017F 235267.83 670828.77 9530-0004-018F 235234.29 670925.74 Revision 0 9

Revision 0 9

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was about 10% of fifteen (15) samples.

The LTP specifies a judgmental scanning coverage for outdoor Class 3 areas.

The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS.

Based on the historical site assessment, the characterization data available, and the use of the survey unit to store spoils from remediation, it was determined that scanning was required in two (2) separate areas. The total surface area to be scanned was approximately 5% of the survey unit. A map of the scan grid locations is provided in Attachment 1.

For this Class 3 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.

Based on AutoCAD-LT Type I and Type 2 errors were 18 0.05, sigma was 0.088 pCi/g, Number of Measurements (15 systematic grid) the LBGR was adjusted to 5.2 (3 biased) to maintain Relative Shift in the range of I and 3 Grid Spacing N/A Not applicable for a Class 3 survey unit Administratively set to achieve Operational DCGL 5.38 pCi/g Cs-137 17 mrem/yr TEDE (1)

A sample result that exceeds Soil Investigation Level 2.69 pCi/g Cs-137 50% of the Operational DCGL meets the LTP criteria for a Class 3 survey unit Revision 0 10

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Scan Survey Area Coverage Design Criweria Approximately 5%

of the area i ne L I F speciriesjuagmentai coverage for Class 3 Survey Units Detectable over Administratively set to achieve background 17 mrem/yr TEDE )

(1) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024.)

5.

SURVEY IMPLEMENTATION Final Status Survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.

The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey.

The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Two (2) scan areas were established that constituted approximately 5% of the surface area of Survey Unit 9530-0004.

Grid lines, one meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 6,080 counts per minute (cpm) up to 8,440 cpm.

The scan areas were established and scanned for elevated readings (see for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 5% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.

At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.

Twenty-five (25) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.

Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Revision 0 I1I Revision 0 11

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD Two (2) samples (9530-0004-003F and 9530-0004-012F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of two (2) samples (9530-0004-004F and 9530-0004-009F) for "split sample" analysis.

6.

SURVEY RESULTS All field survey activities were conducted between August 24, 2006 and September 6, 2006.

The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels.

Table 5 provides an overview of the scan results for sample measurement locations.

Scan results are provided in Attachment 2.

STable 5 -Scan Resuilts for -aimple Measurement Locations

  • Sample Hiphesloged Me~uri~iet Reaing Action Level Measurement Readlngy kAction Level Location (kcpm)).

1 8.39 8.36 YES 2

6.70 8.86 NO 3

7.84 9.19 NO 4

6.60 7.62 NO 5

6.58 8.04 NO 6

7.26 7.47 NO 7

6.37 7.87 NO 8

7.24 8.95 NO 9

7.54 8.21 NO 10 6.92 7.38 NO 11 6.97 9.45 NO 12 8.09 8.55 NO 13 6.92 7.24 NO 14 6.46 6.94 NO 15 5.59 7.48 NO 16 7.38 7.97 NO 17 7.78 8.26 NO Revision 0 12 Revision 0 12

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD 19 6.23 6.52 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level The scan areas, that comprised approximately 5% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on August 24, 2006 and September 6, 2006.

Several elevated measurement locations were identified during scanning.Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.

Iiigisi

  • Table 6..- Scani Area Results
1.

.. ( 1)':

F,-

l e va t e d **** *,

Scan,~ Lged ketdion Level (

e1di)i Investigationa Sre 'I" Reading (kcprn)

Id~enicationg (2)

Sample 9530-04-ER 9530-0004-020F 16-1 9530-04-ER 17-1 9530-0004-021F 17-1 9530-04-ER 9530-0004-022F 23-1 1

10.3 8.44 2-9530-04-ER 9530-0004-023F 23-2 9530-04-ER 9530-0004-024F 24-1 9530-04-ER 9530-0004-025F 26-1 2

8.42 8.31 9530-04-SC 9530-0004-019F 05-0 (1) The action level is based on a measurement above ambient background (2) ER and SC are abbreviations associated with the barcodes used in the field where ER stands for Elevated Reading and SC stands for Scan The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, the three (3) biased samples, and the seven (7) confirmatory samples using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDCs. Gamma spectroscopy results identified some radionuclides Revision 0 13

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty). However, Cs-137 was the only radionuclide reported in concentrations exceeding the de-selection criteria.

Cs-137 was identified in thirteen (13) of the fifteen (15) samples collected for non-parametric statistical testing.

Cs-137 was the primary radionuclide confirming the DQOs. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.

9530-0004-OOI' 1.41E-01 0.026 9530-0004-002F 2.76E-01 0.061 9530-0004-003F 2.12E-01 0.053 9530-0004-004F 2.97E-02 0.057 9530-0004-005F

.1.99E-01 0.091 9530-0004-006F 7.96E-02 0.018 9530-0004-007F 3.53E-01 0.011 9530-0004-008F 1.44E-01 0.054 9530-0004-009F 1.36E-01 0.073 9530-0004-OIOF 6.45E-02 0.053 9530-0004-01 IF 9.81 E-02 0.042 9530-0004-012F 3.80E-02 0.059 9530-0004-013F 8.70E-02 0.042 9530-0004-014F 3.36E-01 0.022 9530-0004-015F 2.06E-02 0.030 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.

Revision 0 14

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates.

None of the HTDs met the criteria for detection (i.e., a result greater than two standard deviations uncertainty).

Three (3) biased samples were collected at a location selected by FSS Supervision based on professional judgment and observation.

Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC.

Fabl~ 8 - Judgmnental or-BiasedI Sanille Resuilts Sanliple NumnberCs13 lColofte p& /

Opeation~al CG0t 1 )

9530-0004-016F 3.80E-02 0.034 9530-0004-017F 6.55E-03 0.030 9530-0004-018F 3.61E-02 0.022 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Ten percent (10%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey." There was acceptable agreement between field split results for Cs-137 at location 9530-0004-009.

However, Cs-137 was not detected in sufficient quantities in the field split results at location 9530-0004-004 to evaluate in accordance with procedure. Evaluation using the reported results for K-40 resulted in acceptable agreement between the field split results at location 9530-0004-004.

The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.

8.

INVESTIGATIONS AND RESULTS Seven confirmatory samples were collected from scan area 1 and scan area 2 at locations exhibiting elevated scan readings. The samples are denoted as shown in Table 6, with the sample results shown in Table 9 below.

Revision 0 15 Revision 0 15

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD 9530-0004-019F 9.65E-02 0.040 9530-0004-020F

-7.36E-03 0.023 9530-0004-021F 7.36E-03 0.032 9530-0004-022F 5.22E-02 0.029 9530-0004-023F 2.60E-02 0.024 9530-0004-024F 4.90E-02 0.030 9530-0004-025F 2.04E-02 0.023 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE

9.

REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 3.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

Revision 0 16

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD For Cs-137, the range of the data, about three (3) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.

The difference between the mean and median was 10% of the standard deviation which indicates some skewness in the data.

The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 0.77.

All data, assessments, and graphical representations are provided in Attachment 4.

12.

ANOMALIES No anomalies were noted.

13.

CONCLUSION Survey Unit 9530-0004 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.

Cs-137 was used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 3.

The dose contribution from soil is less than 1 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3 mrem/yr TEDE.

Therefore, Survey Unit 9530-0004 is acceptable for unrestricted release.

Revision 0 17 Revision 0 17

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD

14.

ATTACHMENTS 14.1 Attachment 1 - Survey Unit Location Map 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 18

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 1 (FIGURES)

_-COM977Ecncu RIMA-( \\ Connecticut Yankee Atomic Power Company Site Map With Reference To Survey Unit 9530-0004

Wadwd edfan ON U

0 110 220 Connecticut Yankee Atomic Power Company Survey Unit 9530-0004 Final Status Survey Des'gn

jf&_M__d

- Wed,,d

-Nbthhdn*dlp 9530-004 0

Ito 220dj Fed~

Notes Concernumsinzsh PMi9 CoMecnjcut Yankee Atomic Power Company Survey Unit 9530-0004 Final Status Survey Cs-137Postngpjot

Survey U

i 953 F au W 2 d~t~d*bymn P~e~ *Tabt6far m

SmrvC, Umt 9530-6W04 Final Status Smryey Scan Areas

U Nbt mhK*dbM' 0WO SmezSAzuu 0

-MkP~

0 Io 220 Feed VI Notes Refrfto Tabl 8 fi biadsampkrwdb Rlfw to Tabk 9 fir Gmfrzldmmy sple lambi Conmecticut Yankee Atomic Power Company Survey Unit 9530-0004 Final Status Survey Biased and Conmastory Samples

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Survey Release Record Sample Location Scan Results Survey Unit 9530-0004 Sample Name

Background

Action Level Results Above Loq Date Log Time E600 SIN Probe SIN (cIm)

(cPm)

(cIm)

AL 9530-04-SL-00-01-0 7.15E+03 8.36E+03 8.39E+03

+

8/25/2006 9:52:00 1107 1013 9530-04-SL-00-02-0 7.61E+03 8.86E+03 6.70E+03 8/25/2006 10:22:00 1107 1013 9530-04-SL-00-03-0 7.92E+03 9.19E+03 7.84E+03 8/28/2006 9:50:00 1117 1001 9530-04-SL-00-04-0 6.47E+03 7.62E+03 6.60E+03 8/25/2006 8:22:00 1107 1013 9530-04-SL-00-05-0 6.86E+03 8.04E+03 6.58E+03 8/28/2006 10:21:00 1117 1001 9530-04-SL-00-06-0 6.33E+03 7.47E+03 7.26E+03 8/24/2006 14:35:00 1114 1014 9530-04-SL-00-07-0 6.70E+03 7.87E+03 6.37E+03 8/28/2006 10:11:00 1117 1001 9530-04-SL-00-08-0 7.70E+03 8.95E+03 7.24E+03 8/28/2006 9:47:00 1117 1001 9530-04-SL-00-09-0 7.01E+03 8.21E+03 7.54E+03 8/25/2006 8:35:00 1107 1013 9530-04-SL-00-10-0 6.25E+03 7.38E+03 6.92E+03 8/25/2006 10:35:00 1107 1013 9530-04-SL-00-11-0 8.16E+03 9.45E+03 6.97E+03 8/24/2006 14:42:00 1114 1014 9530-04-SL-00-12-0 7.33E+03 8.55E+03 8.09E+03 8/25/2006 10:50:00 1107 1013 9530-04-SL-00-13-0 6.12E+03 7.24E+03 6.92E+03 8/25/2006 9:43:00 1107 1013 9530-04-SL-00-14-0 5.85E+03 6.94E+03 6.46E+03 8/24/2006 14:24:00 1114 1014 9530-04-SL-00-15-0 6.34E+03 7.48E+03 5.59E+03 8/25/2006 10:12:00 1107 1013 9530-04-SL-00-16-0 6.79E+03 7.97E+03 7.38E+03 8/24/2006 14:05:00 1114 1014 9530-04-SL-00-17-0 7.06E+03 8.26E+03 7.78E+03 8/24/2006 13:52:00 1114 1014 9530-04-SL-00-18-0 7.94E+03 9.21 E+03 8.23E+03 8/24/2006 14:15:00 1114 1014 9530-04-SL-00-19-0 5.46E+03 6.52E+03 6.32E+03 8/25/2006 10:00:00 1107 1013 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9530-0004 9530-0004 SCAN AREA 1 Sample Name 9530-04-SC-01-01-0 9530-04-SC-01-02-0 9530-04-SC-01-03-0 9530-04-SC-01-04-0 9530-04-SC-01-05-0 9530-04-SC-01-06-0 9530-04-SC-01-07-0 9530-04-SC-01-08-0 9530-04-SC-0l-09-0 9530-04-SC-01-10-0 9530-04-SC-01-11-0 9530-04-SC-01-12-0 9530-04-SC-01-13-0 9530-04-SC-01-14-0 9530-04-SC-01-15-0 9530-04-SC-01-16-0 9530-04-ER-01-16-1 9530-04-SC-01-17-0 9530-04-ER-01-17-1 9530-04-SC-01-18-0 9530-04-SC-01-19-0 9530-04-SC-01-20-0 9530-04-SC-01-21-0 9530-04-SC-01 0 9530-04-SC-01-23-0 9530-04-ER-01-23-1 9530-04-ER-01-23-2 9530-04-SC-01-24-0 9530-04-ER-01-24-1

Background

(c m) 7.02E+03 7.29E+03 7.18E+03 6.87E+03 7.55E+03 7.11 E+03 6.82E+03 7.95E+03 6.73E+03 7.79E+03 7.05E+03 7.11 E+03 7.22E+03 7.50E+03 7.06E+03 7.23E+03 7.23E+03 7.38E+03 7.38E+03 7.45E+03 7.94E+03 7.62E+03 6.58E+03 7.76E+03 7.91E+03 7.91 E+03 7.91 E+03 6.87E+03 6.87E+03 Action Level fCPM) 8.22E+03 8.51 E+03 8.39E+03 8.05E+03 8.79E+03 8.31E+03 8.OOE+03 9.22E+03 7.90E+03 9.05E+03 8.25E+03 8.31 E+03 8.43E+03 8.74E+03 8.26E+03 8.44E+03 8.44E+03 8.61 E+03 8.61 E+03 8.68E+03 9.21 E+03 8.87E+03 7.74E+03 9.02E+03 9.18E+03 9.18E+03 9.18E+03 8.05E+03 8.05E+03 Results Above Log Date Log Time E600 S/N Probe S/N 6.42E+03 8.31 E+03 7.64E+03 7.17E+03 7.1OE+03 7.20E+03 6.95E+03 7.85E+03 7.54E+03 7.55E+03 6.71 E+03 7.35E+03 7.56E+03 8.05E+03 6.99E+03 6.70E+03 1.02E+04 6.55E+03 9.09E+03 8.01 E+03 7.71E+03 8.61 E+03 7.35E+03 7.19E+03 7.37E+03 1.03E+04 9.63E+03 7.55E+03 9.35E+03 AL 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006

+

9/6/2006 9/6/2006

+

9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006 9/6/2006

+

9/6/2006

+

9/6/2006 9/6/2006

+

9/6/2006 8:39:00 8:43:00 9:48:00 9:51:00 9:55:00 9:59:00 10:04:00 10:08:00 8:03:00 8:08:00 8:12:00 8:16:00 8:22:00 8:27:00 8:31:00 10:20:00 13:47:00 10:30:00 13:48:00 10:38:00 10:45:00 10:52:00 10:07:00 10:17:00 10:33:00 13:51:00 13:52:00 10:49:00 13:54:00 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1117 1117 1117 1114 1114 1117 1114 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1008 1008 1008 1014 1014 1008 1014 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9530-0004 9530-04-SC-01-25-0 9530-04-SC-01-26-0 9530-04-ER-01-26-1 9530-04-SC-01-27-0 7.32E+03 6.90E+03 6.90E+03 8.44E+03 8.54E+03 8.09E+03 8.09E+03 9.75E+03 6.91 E+03 6.13E+03 9.03E+03 6.69E+03 9/6/2006 9/6/2006

+

9/6/2006 9/6/2006 11:00:00 11:10:00 13:56:00 11:15:00 1117 1117 1114 1117 1008 1008 1014 1008 9530-0004 SCAN AREA 2 Sample Name 9530-04-SC-02-01 -0 9530-04-SC-02-02-0 9530-04-SC-02-03-0 9530-04-SC-02-04-0 9530-04-SC-02-05-0 9530-04-SC-02-06-0 9530-04-SC-02-07-0 9530-04-SC-02-08-0 9530-04-SC-02-09-0 9530-04-SC-02-1 0-0 9530-04-SC-02-1 1-0 9530-04-SC-02-12-0 9530-04-SC-02-13-0 9530-04-SC-02-14-0 9530-04-SC-02-15-0 9530-04-SC-02-16-0 9530-04-SC-02-17-0 9530-04-SC-02-18-0 9530-04-SC-02-19-0 9530-04-SC-02-20-0 9530-04-SC-02-21 -0 9530-04-SC-02-22-0 9530-04-SC-02-23-0 9530-04-SC-02-24-0

Background

(cPM) 6.39E+03 7.55E+03 6.99E+03 6.43E+03 7.11E+03 8.24E+03 6.60E+03 8.03E+03 7.55E+03 7.98E+03 6.62E+03 7.37E+03 6.96E+03 6.78E+03 6.49E+03 7.02E+03 7.57E+03 6.93E+03 8.12E+03 7.82E+03 7.86E+03 8.44E+03 6.76E+03 7.41 E+03 Action Level (CPM) 7.53E+03 8.79E+03 8.18E+03 7.58E+03 8.31 E+03 9.54E+03 7.76E+03 9.31 E+03 8.79E+03 9.26E+03 7.78E+03 8.60E+03 8.15E+03 7.96E+03 7.64E+03 8.22E+03 8.81 E+03 8.12E+03 9.41 E+03 9.08E+03 9.13E+03 9.75E+03 7.93E+03 8.64E+03 Results 7.20E+03 6.76E+03 6.21 E+03 5.92E+03 8.42E+03 6.78E+03 7.31 E+03 7.88E+03 7.01 E+03 6.79E+03 7.51 E+03 6.11E+03 7.22E+03 7.21 E+03 7.36E+03 6.22E+03 7.38E+03 6.71 E+03 7.72E+03 7.54E+03 6.92E+03 7.75E+03 7.05E+03 6.77E+03 Above Log Date AL 8/24/2006 8/24/2006 8/24/2006 8/24/2006

+

8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 8/24/2006 Log Time 10:59:00 11:01:00 11:06:00 11:09:00 11:17:00 11:14:00 11:12:00 11:08:00 11:04:00 11:01:00 9:44:00 9:48:00 9:54:00 10:01:00 10:07:00 10:13:00 10:20:00 10:27:00 10:32:00 10:39:00 10:35:00 10:29:00 10:23:00 10:16:00 E600 SIN 1117 1117 1117 1117 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1114 1117 1117 1117 1117 Probe SIN 1001 1001 1001 1001 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1014 1001 1001 1001 1001 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9530-0004 9530-04-SC-02-25-0 7.95E+03 9.22E+03 7.01E+03 8/24/2006 10:08:00 1117 1001 9530-04-SC-02-26-0 7.76E+03 9.02E+03 6.81 E+03 8/24/2006 10:02:00 1117 1001 9530-04-SC-02-27-0 7.79E+03 9.05E+03 7.46E+03 8/24/2006 9:56:00 1117 1001 9530-04-SC-02-28-0 7.50E+03 8.74E+03 6.83E+03 8/24/2006 9:50:00 1117 1001 9530-04-SC-02-29-0 6.96E+03 8.15E+03 7.81 E+03 8/24/2006 9:46:00 1117 1001 9530-04-SC-02-30-0 6.08E+03 7.19E+03 6.23E+03 8/24/2006 9:40:00 1117 1001 AL - Action Level

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

General Narrative I

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 171454 SDG: MSR#06-1236 September 21, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on September 12, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures. Upon receipt, the collect date and time for Sample 9530-0004-006F was noted as being incorrect on the COC. Jack McCarthy confirmed via email that the container information was correct.

The laboratory received the following sample(s):

Sample ID Client Sample ID 171454001 9530-0004-006F 171454002 9530-0004-01IF 171454003 9530-0004-014F 171454004 9530-0004-016F 171454005 9530-0004-017F 171454006 9530-0004-018F 171454007 9530-0004-004F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax (843) 766-1178
  • www.gel.com

171454008 171454009 171454010 171454011 171454012 171454013 171454014 171454015 171454016 171454017 171454018 171454019 171454020 171454021 171454022 171454023 171454024 171454025 171454026 171454027 9530-0004-004FS 9530-0004-009F 9530-0004-009FS 9530-0004-013F 9530-0004-001F 9530-0004-019F 9530-0004-015F 9530-0004-002F 9530-0004-OIOF 9530-0004-008F 9530-0004-007F 9530-0004-005F 9530-0004-020F 9530-0004-02iF 9530-0004-022F 9530-0004-023F 9530-0004-024F 9530-0004-025F 9530-0004-012F 9530-0004-003F Items of Note:

There are no items of note.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Twenty-five soil samples were analyzed for FSSGAM.

Two soil samples were analyzed for FSSALL.

Internal Chain of Custody:

Custody was maintained for the sample(s).

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

P.O. Box 30712

  • Charleston, SC 29417 ° 2040 Savage Road (29407)

Phone (843) 556-8171 ° Fax (843) 766-1178

  • www.gel.com 5

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chainof Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

RO. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax (84*) 766-1178
  • www.gel.com

List of current GEL Certifications as of 21 September 2006

"..state Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 alif-oria "0I 15iCA Colorado.

GenEngL..abs

... Connecticut PH-0169 Dept. of Navy' N-FEC 41-3 EPA WG-15J j

Florida/NELAP...

E871t56 _____

.Georgia E87_156 (FLINELAP)

Hawaii N/A Idaho N/A Illinois-..

200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 M. chli.an 93 Nevada*

SCI 2 New Jersey SCO02

--New Mexico..

FL NELAP E87156 New York 11501 North Carolina

._- 233 I

North Carolina Drinking W 45709 North Dakota R-158 SOklahoma 9904 Pennsylvania 68-00485 South Carolina 1012000i/

58500-l1l0120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont..

VT87156 Virginia 00151 Washington 5

Chain of Custody And Supporting Documentation-6

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form No. 2006-00521 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

D] 30 D. E 14 D. F] 7 D. ] 3 D.Container "7-Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-006F 8/24/06 1440 TS G

BP X

9530-0004-01IF 8/24/06 1448 TS G

BP X

9530-0004-014F 8/24/06 1422 TS G

BP X

9530-0004-016F 8/24/06 1404 TS G

BP X

9530-0004-017F 8/24/06 1348 TS G

BP X

9530-0004-018F 8/24/06 1414 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-1214 SSWP# NA Z LTP QA D Radwaste QA F1 Non QA Samples Shipped Via:

Internal Container Z Fed Ex Temp.: ZI Deg.

L] UPS C

El Hand Custody Sealed?

YOI NC

1) Relinquish y

Date/Time

2) Received By Date/Time Custody Seal (I/d&

ke~aive(dy4

![

Other Intact?

3) RelinquishedBy Date/Time
4) Rqeived By Date/Time BillofLading_#

YO NO Bill of Lading #

5) Relinquished By Date/Time
6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00522 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones u

Cn Priority: [] 30 D. Z 14 D. [_

7 D.D] 3 D.

Container Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-004F 8/25/06 0823 TS G

BP X

9530-0004-004FS 8/25/06 0823 TS G

BP X

9530-0004-009F 8/25/06 0835 TS G

BP X

9530-0004-009FS 8/25/06 0835 TS G

BP X

9530-0004-013F 8/25/06 0950 TS G

BP X

9530-0004-00IF 8/25/06 0952 TS G

BP X

9530-0004-019F 8/25/06 1003 TS G

BP X

9530-0004-015F 8/25/06 1013 TS G

BP X

9530-0004-002F 8/25/06 1023 TS G

BP X

9530-0004-OIOF 8/25/06 1037 TS G

BP X

9530-0004-012F 8/25/06 1058 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-1W3t SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via:

Z Fed Ex El UPS r_

Hand El Other Bill of Lading #

Internal Container Temp.: 2-) Deg.

C Custody Sealed?

YO ND Custody Seal Intact?

YO NO

1) Relinquished By Date/Time
2) Rýceived Bj/.

Date/Time

3) Relinquis By Date/Time
4) 3zeived By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00523 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

1] 30 D. [K 14 D. D1 7 D.

3 D.

Container Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-008F 8/28/06 0946 TS G

BP X

9530-0004-003F 8/28/06 0955 TS G

BP X

9530-0004-007F 8/28/06 1012 TS G

BP X

9530-0004-005F 8/28/06 1020 TS G

BP X

II I

.1.. 1 1 1.1 1 1-1 1

NOTES: PO #: 002332 MSR #: 06-a14 SSWP# NA Z LTP QA E] Radwaste QA IZ Non QA Samples Shipped Via:

Z Fed Ex

[] UPS FD Hand ED Other Bill of Lading #

Internal Container Temp.: _7 Deg.

C Custody Sealed?

YE NO Custody Seal Intact?

YE NEI

1) Relinquis y

Data/Time

2) ceBive Date/Time
3) Relinquishei/By Date/Time
4) eceived By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form No. 2006-0053 5 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones V

Priority: 0 30 D. Z 14 D. Ej 7 D. E] 3 D.

Container Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0004-020F 9/6/06 1350 TS G

BP X

9530-0004-021F 9/6/06 1355 TS G

BP X

9530-0004-022F 9/6/06 1400 TS G

BP X

9530-0004-023F 9/6/06 1402 TS G

BP X

9530-0004-024F 9/6/06 1407 TS G

BP X

9530-0004-025F 9/6/06 1410 TS G

BP X

L I

L L

.1 _______ I.

A.

£ L...................h..

4 NOTES: PO #: 002332 MSR #: 06- /Z31 SSWP# NA Z LTP QA El Radwaste QA D1 Non QA Samples Shipped Via:

Z Fed Ex

[l UPS

[] Hand ED Other Bill of Lading #

Internal Container Temp.: 2,1 Deg.

C Custody Sealed?

YE NEI Custody Seal Intact?

YE NO

1) Relinquished B Date/Time
2) Received Date/Time
3) Relinquished By Date/Time
4) ]Kceived By Date/Time V

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:

'[/cl2 0

l 'o "3 Work Order Number:

+ 145 I. {, 1 Shipping Cdntainer ID:-. 5

'" C Chain of Custody#

'-?i*

(iJ

1.

Custody Seals. orf shipping container intact?.

Yes t I No [ ] A) A

2.

Custody Seals dated and signed?

Yes[ [INo [ ]

/

3.

Chain-of-Custo'Jy record present?

Yes, No [ ]
4.

Cooler temperature 2i t

5.

Vermiculite/packing materials is:

Wet [ ] Dry pt

] p-A-6.:

Number of samples in shipping container:

5ee-cim.

7.

Sample holding times exceeded?

Yes [ ] No [t

.8. Samples have:

.X'tape

-hazard labels custody seals i__appropriate sample labels

9. Samples are:

._..ýin good condition leaking

-broken have air bubbles

10.

Were any anomalies identified in sample receipt?

Yes No [ ]

11.

Description of anomalies (include sample numbers):

,.?

  • 6

,1+/-.

Sample Custodian/Laboratory: /

-4*

Date: q /(

Telephoned to:

On By On----B

p,?

SAMPLE RECEIPT & REVIEW FORM C,

PM use only Client: CZAu.

Z

,, ice _SDG/ARCOCIWork Order:

'if Date Received:

Ci[(/

PM(A) Review ensure non-confor 'ng items are resolved prior to signing):

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conformin ems)

Shipping containers received intact Circle Applicable: seals broken damaged container leaking con er other (describe) and sealed?

7 Samples requiring cold Circle Coolant #

ice bags blue ice ice none other describe) 2 preservation within (4 +/- 2 C)?

Record preservation method.

Chain of custody documents included with shipment?

Sample containers intact and Circle Applicable: seals b en damaged container leaking container other (describe) sealed?

Samples requiring chemical Sample ID's.

nainers affected and observed pH:

preservation at proper pH?

6 VOA vials free of headspace S ple ID's and containers affected:

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA *laborato0__

Samples received within holdi Id's and tests affected:

time?

9 Sample ID's on COC tch ID's Sample ID's and containers affected:

on bottles?

Date & time o OC match date Sample ID's affected:

&apl time onffeted:

Numb7e f containers received Sample ID's affected:

matOf number indicated on COC?

form is properly signed in Arlnuse/received sections?

'>5o 0\\

£C-.Y2, 00,5-z k oorz)",

o>0?

05z-, C0530, Air Bill,Tracking #'s, &

0C6. 6"2.. 05o "sj s-u1 Additional Comments

-6 RSORADReceipt#

  • If > x2 area background is observed on samples identified as "non-Suspected Hazard Information 30-Su-ce a

regulated/non-radioactive", contact the Radiation Safety group for further a*

Z investigation.

A Radiological Classification?

'Maximum Counts Observed*:

0 7 PCB Regulated?

Comments:

b Shipped as DOnT Hazardous C Material? If yes, contact Waste

/"

Hazard Class Shipped:

1 Manager or ESH Manager.

UN#:

PM (or PMA) review of Hazard classification:

Initials L11*

Date: "A I CL,

A)1ý rSAMPLE RECEIPT & REVIEW FORM J

o CONTINUATION FORM Client:

Date Received:

6a1k, tAIe

ýr4kCoe

-4.r~~t4r w4.Ir 7q5 £fo7

-005 zti 7410 IoO6 o-SL Soa6-oo0s 3 7 5-9 0 o o f

9 o-oosZ.7 To4.,

41cb. s -U

-Lo7a c6,-doo 2 I r

r 11)

RADIOLOGICAL ANALYSIS 14

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 171454 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Ash Soil Prep Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Dry Soil Prep 567824 567639 567634 Sample ID 171454026 1.71454027 1201181597 1201181598 1201181599 1201181600 Client ID 9530-0004-012F 9530-0004-003F Method Blank (MB) 171450001(9520-04-1 C) Sample Duplicate (DUP) 171450001(9520-04-1 C) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

15

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171450001 (9520-04-IC),

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set'were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 16

Product:

Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Ash Soil Prep Dry Soil Prep 567825 567639 Dry Soil Prep GL-RAD-A-021 Batch Number:

567634 Sample ID 171454026 171454027 1201181601 1201181602 1201181603 1201181604 Client ID 9530-0004-012F 9530-0004-003F Method Blank (MB) 171450001(9520-04-IC) Sample Duplicate (DUP) 171450001(9520-04-1 C) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01I1 REV# 14.

Calibration Information:

Calibration Irnormation All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same g~ometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171450001 (9520-04-IC).

QC Information All of the QC samples met the required acceptance limits.

17

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP, or contractual documents. A nonconformance.report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

567826 Prep Batch Number:

567639 Dry Soil Prep GL-RAD-A-021 Batch Number:

567634 18

Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181605 Method Blank (MB) 1201181606 171450001(9520-04-4C) Sample Duplicate (DUP) 1201181607 171450001(9520-04-IC) Matrix Spike (MS) 1201181608 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171450001 (9520-04-1C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 19

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product' Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 569467 567633 20

Sample ID 171454001 171454002 171454003 171454004 171454005 171454006 171.454007 171454008 171454009 171454010 171454011.

171454012 1,7145401.3 171454014 171454015 171454016 17145401.7 17145401.8 171454019 171454020 1201185425

'1201185426 1201185427 Client ID 9530-0004-006F 9530-0004-01 1F 9530-0004-014F 9530-0004-016F 9530-0004-017F 9530-0004-018F 9530-0004-004F 9530-0004-004FS 9530-0004-009F 9530-0004-009FS 9530-0004-013F 9530-0004-OOIF 9530-0004-019F 9530-0004-015F 9530-0004-002F 9530-0004-01OF 9530-0004-008F 9530-0004-007F 9530-0004-005F 9530-0004-020F Method Blank (MB) 171454001(9530-0004-006F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as StandamId Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171454001 (9530-0004-006F).

21

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparationcriteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR Was generated for this SDG:

NCR 364074 was generated due to Failed RPD for DUP. 1. Samples 171454001 and 1201,185426ý did not meet the relative percent difference for K-40. 1. K-40 is a naturally occurring isotope. Reporting results.

Additional. Comments Sample 1201185425 (MB) did not meet the relative percent difference requirement for Bi-212, however it does meet the relative error ratio requirement with value of 2.6.

Oualifier information Qualifier UI UI UI Reason Data rejected due to high peak-width.

Data rejected due to interference.

Data rejected due to low abundance.

Analyte Cesium-134 Europium-155 Actinium-228 Cesium-134 Sample 171454002 1.71454001 171454020 171454005 171454003 171454012 171454020 Method/AnalvMs Information 22

Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Sample ID 171454021 171454022 171454023 171454024 171454025 1.71454026 1.71454027 1201185428 1201185429 1201185430 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 569468 567634 Client ID 9530-0004-021F 9530-0004-022F 9530-0004-023F 9530-0004-024F 9530-0004-025F 9530-0004-012F 9530-0004-003F Method Blank (MB) 171454021(9530-0004-021F) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are'NIST traceable and used before the expiration date(s).

Sample Geometry All counting sourceswere prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume 'is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171454021 (9530-0004-021F).

QC Information All of the QC samples met the required acceptance limits.

23

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 171454022 (9530-0004-022F) and 171454024 (9530-0004-024F) were recounted due to high MDAs.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any pr6cedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and duplicate 1201185429 (9530-0004-021F) and 171454021 (9530-0004-021F) did not meet the relative percent difference requirement for Ac-228 and CS-137, however they do meet the relative error ratio requirement with a value of 2.03908 for Ac-228 and 0.2934 for Cs-137, Gualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance.

Cesium-134 171454024 171454027 Method/Analysis Information Product:

GFPC, Sr90, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch Number:

Ash Soil Prep Dry Soil Prep 567998 567639 Dry Soil Prep GL-RAD-A-021 Batch Number:

567634

'24

Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181989 Method Blank (MB) 1201181990 171450001(9520-04-IC) Sample Duplicate (DU'P) 1.201181991 171450001(9520-04-1C) Matrix Spike (MS) 1201181992 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

'Designated QC The following sample was used for QC: 171450001 (9520-04-1C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the' samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

25

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Analytical Batch Number:

Sample ID 171454026 171454027 1201181858 1201181859 1201181860 1.201181861 Liquid Scint Tc99, Solid-ALL FSS DOE EML HASL-300, Tc-02-RC Modified 567935 Client ID 9530-0004-012F 9530-0004-003F Method Blank (MB) 171454026(9530-0004-012F) Sample Duplicate (DUP) 171454026(9530-0004-01.2F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering LUiboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-.005 REV# 13.

CnJibrntian Jnfnrinntinn:

Calibration Information All initial and continuing calibration requirements, have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before'the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

26

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 171454026 (9530-0004-012F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were recounted due to high MDAs.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents'. A noneonformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-I, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

567933 Prep Batch Number:

567639 Dry Soil Prep GL-RAD-A-021 Batch Number:

567634 27

Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181849 Method Blanik (MB) 1201181850 171450001.(9520-04-IC) Sample Duplicate (DUP) 1201181851 171450001(9520-04-IC) Matrix Spike (MS) 1201181852 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration' Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171450001 (9520-04-1C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample proceduresfor this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201181849 (MB), 1201181850 (9520-04-1C), 1201181851 (9520-04-1C), 1201181852 (LCS), 171454026 (9530-0004-01.2F) and.,171.454,027 (9530-0004-003F) were recounted due to the.

quench number being outside the calibration range.

28

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-I, Modified Prep Method:

Dry Soil Prep GL-RAD-A-021 Method:

Analytical Batch Number:

Prep Batch N Limber:

Dry Soil Prep GL-RAD-A-021 Batch Number:

Ash Soil Prep Dry Soil Prep 567934 567639 567634'*

Sample ID 171454026 171454027 1201181854 1201181.855 1201181856 1201181857 Client !.D

/

9530-0004-012F 9530-0004-003F Method Blank (MB) 171450001 (9520-04-iC) Sample Duplicate (DUP) 1.71450001(9520-04-1C) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

29

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank vofume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171450001 (9520-04-1C).

QC Information All of the QC samples met the required acceptarce limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method:

EPA 906.0 Modified Analytical Batch Number:

567994 30

Sample ID Client ID 171454026 9530-0004-012F 171454027 9530-0004-003F 1201181977 Method Blank (MB) 1201181978 171454026(9530-0004-012F) Sample Duplicate (DUP) 1201181979 171454026(9530-0004-012F) Matrix Spike (MS) 1201.181980 Laboratory Control Sample (LCS)

SOP Reference Procedure foripreparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzedin accordance with GL-RAD-A-002 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s)'for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sourceS were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 171454026 (9530-0004-012F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 171454027 (9530-0004-003F) was recounted due to the quench number being outside the calibration range.

31

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 361821 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the samples 171454026, 171454027, 171459018, and 171459019 into the batch prior to analysis, however the samples did remain in their custody at all times. 1. The error has bet.n corrected and the analyst has been instructed on the proper scanning procedures.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Analytical Method:

Analytical Batch Number:

Sample ID 171.454026 171454027 1201181862 1201181863

.1201181864

.71201181865 Liquid Scint C14, Solid All,FSS EPA EERF C-01 Modified 567937 Client ID 9530-0004-012F 9530-0004-003F Method Blank (MB) 171454026(9530-0004-012F) Sample Duplicate (DUP) 171454026(9530-0004-012F) Matrix Spike (MS)

Laboratory Control Sample (LCS)

SOP Reference.

Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance/with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry 32

All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 171454026 (9530-0004-012F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Gualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method, has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical-case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

33

Kdý'&d-,c Reviewer/Date:

,¢,"

34

General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:

361821 Revision No.:

COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.

Division:

Quality Criteria:

Type:

21 -SEP-06 Radiochemistry Specifications Process Instrument Type:

Test / Method:

Matrix Type:

Client Code:

LSC EPA 906.0 Modified Solid YANK Batch ID:

Sample Numbers:

567994 See Below Potentially affected work order(s)(SDG): 171454(MSR#06-1236),171459(MSR#06-1237)

Application Issues:

Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. The analyst did not scan the samples 171454026, 171454027, 171459018, and 171459019 into the batch prior to analysis, however the samples did remain in their custody at all times.

Originator's Name:

Amy Scott 21-SEP-06 Quality Review:

1. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Data Validator/Group Leader:

Melanie Aycock 22-SEP-06 Director:

Page 1 35

General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:

364074 Revision No.:

COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.

26-SEP-06 Instrument Type:

GAMMA SPECTROMETER Division:

Quality Criteria:

Radiochemistry Specifications Test / Method:

Matrix Type:

EML HASL 300, 4.5.2.3 Solid Sample Numbers:

See Below Type:

Process Client Code:

YANK Batch ID:

569467 Potentially affected work order(s)(SDG): 171454(MSR#06-1236)

Application Issues:

Failed RPD for DUP Specification and Requirements Nonconformance

Description:

NRG Disposition:

1. K-40 is a naturally occurring isotope. Reporting results.
1. Samples 171454001 and 1201185426 did not meet the relative percent difference for K-40.

Originator's Name:

Heather Anderson Quality Review:

Data Validator/Group Leader:

26-.SEP-06 Director:

Page 1 36

SAMPLE DATA

SUMMARY

/ 37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1236 GEL Work Order: 171454 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843).556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

September 26, 2006 Ilient Sample ID:

9530-0004-006F Project:

YANK01204 Sample ID:

171454001 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

22-AUG-06 Receive Date:

12-SEP-06 Collector:

Client Moisture:

5.63%

Parameter Qualifier Result Uncertainty

.LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.490 Americiulm-241 U

0.112 Bislnuth-212 U

0.163 Bismuth-214 0.348 Cesium-134 U

0.0339 Cesium-137 0.0796 4

Cobalt-60 U

0.00766 Europium-152 U 0.000266 4

Europium-I154 U

0.0642 Europium-155 UI 0.00 Lead-212 0.465 4

Lead-214 0.417 4

Manganese-54 U

0.0199 Niobium-94 U

0.016

+

Potassium-40 9.54 Radium-226 0.348 Silver-108m U

-0.0181 4

Thallium-208 0.150 4

+/-0.141

+/-0.121

+/-0.172

+/-0.081

+/-0.017

/--0.0245

-/-0.0254

-/-0.0528

+/-0.080

+/-0.100

-/-0.0565

-/-0.0853

+/-0.019 1/-0.0153

+/-0.855

+/-0.081

./-0.0169

-/-0.0344 0.0556 0.0788 0.164 0.0327 0.0216 0.0159 0.020 0.046 0.0603 0.0485 0.0242 0.0294 0.0178 0.0158 0.162 0.0327 0.0139 0.0204

+/-0.141

+/-0.121

+/-0.172

+/-0.081

+/-0.017

+/-0.0245

+/-0.0254

+/-0.0528

+/-0.080

+/-0.100

+/-0.0565

+/-0.0853

+/-0.019

+/-0.0153

+/-0.855

+/-0.081

+/-0.0169

+/-0.0344 0.125 0.166 0.354 0.0712 0.0473 0.0351 0.0454 0.0984 0.135 0.102 0.0515 0.0634 0.0393 0.0347 0.376 0.0712 0.0302 0.0438 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g.

MJH1 09/20/06 0720 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 2C407 - k843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-006F Project:

YANK01204 Sample ID:

171454001 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on.a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gei com Certificate of: Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack'McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-011F 171454002 TS 24-AUG-06 12-SEP-06 Client 3.34%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier

'Result Uncertainty LC TPU MDA Units DF Analyst Date Time'Batch Mtd Rad Gamma Spec Analysis Gamna,oSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.610 Americium-241 U

0.0767 Bismuth-212 U

0.349 Bismuth-214 0.489

+

Cesium-134 Ut 0.00 Cesium-137 0.0981 Cobalt-60 U

0.0248

-m Europium-152 U

-0.0292 Europium-154 U

0.0309

  • Europium-155 U -2.1OOE-

+/-0.168

+/-0.0879

+/-0.331

-/-0.0888

+/-0.063 4-0.0549 4/-0.0237

-/-0.0702 4-0.0754

/-0.0652

-/-0.0757

+/-0.0922

+/-0.023

-/-0.0304

+/-1.02

-/-0.0888

+/-0.021

+/-0.053 0.0674 0.0853 0.166 0.0386 0.0221 0,0213 0.0232 0.0516 0.0678 0,0585 0.0326 0.0394 0.0195 0.0209 0.151 0.0386 0.017 0.0169

+/-0.168

+/-0.0879

+/-0.331

+/-0.0888

+/-0.063

+/-0.0549

+/-0.0237

+/-0.0702

+/-0.0754

+/-0.0652

+/-0.0757

+/-0.0922

+/-0.023

+/-0.0304

+/-1.02

+/-0.0888

+/-0.021

+/-0.053 0.149 0.178 0.360 0.0832 0.0483 0.046 0.0519 0.110 0.150 0.122 0.0683 0.0837 0.0427 0.0449 0.356 0.0832 0.0366 0.0371 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 0720 569467 1

Lead-2 12 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 05 0.682 0.449 U -0.00136 U

0.00947 11.3 0.489 U

-0.0129 0.169

-I

-i

-1 The following Prep Methods were performed Method Description Analy~st Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09-/12/06 1739 300.

The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value r!?ported 41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-01IF Proiect:

YANKO 1204 Sample ID:

171454002 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspez'ted aldol-, condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low

C Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

  • UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier

'Y QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy

/

Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:;

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result U

Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.647 AmericiUm-241 U

0.0274 Bismuth-212 0.571 Bismuth-214 0.648 CesiuM-134 UI 0.00

+

Cesium-137 0.336

+

Cobalt-60 U -0.00958

+

Europium-152 U

-0.0469

-+

Europium-154 U

-0.0251 4

Europium-155 U

0.0421

+

Lead-212 0.754

+

Lead-214 0,626 Manganese-54 U

0.00646

+

Niobium-94 U

0.00844

+

Potassium-40 10.1 Radium-226 0.648 Silver-108m U -0.00146

+

Thallium-208 0.224

+

9530-0004-014F 171454003 TS 24-AUG-06 12-SEP-06 Client 7.65%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.176

+/-0.115

+/-0.285

+/-0.116

/-0.0444

/-0.0536

/-0.0275

/-0.0768

/-0.0721

/-0.0645

/-0.0813

-/-0.0936

/-0.0273

/-0.0223

+/-1.07

+/-0.116

/-0.0247

/-0.0567 0.0821 0.0898 0.181 0.0363 0.0315 0.0209 0.0223 0.0617 0.0585 0.0597 0.0369 0,0448 0.0234 0.0197 0.179 0.0363 0.0202 0.0241

+/-0.176

+/-0.115

+/-0.285

+/-0.116

+/-0.0444

+/-0.0536

+/-0.0275

+/-0.0768

+/-0.0721

+1-0.0645

+/-0.0813

+/-0.0936

+/-0.0273

+/-0.0223

+/-1.07

+/-0.116

+/-0.0247

+/-0.0567 0.178 0.187 0.389 0.0783 0.067 0.0452 0.050 0.130 0.132 0.124 0.0768 0.0943 0.0506 0.0423 0.411 0.0783 0.0429 0.0513 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/26/06 0917569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed

Method, Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.6el.com Certificate of Analysis Company :. Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-014F Project:

YANK01204 Sample ID:

171454003 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU NMIDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or mnore R

Sample results are rejected U

Analyte was analyzed for, but not detected above the,DL, MDA, or LOD.

UI Gamma Spectroscopy,--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis

[ --

Company :

Connecticut Yankee Atomic Power Address: " 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr.: Jack McCarthy Project:

Soils PO# 002332 Report Date:

September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-016F 171454004 TS 24-AUG-06 12-SEP-06 Client 4,11%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis "I.

Gamma, Solid-FSS GAM & ALL I SS 226 Ingrowth Waived Actinium-228 0.475

+/-0.180 Americium-241 U

-0.0329

+/-0.103 Bismuth-212 0.305

+/-0.215 Bismuti-214 0.459

+/-0.102 Cesium-134 U

0.0523

+/-0.0377 Cesium-137 U

0.038

+/-0.0342 Cobalt-60 U

-0.0109

+/-0.0209 Europium-' 152 U

0.00609

+/-0.0548 Europium-154 U

0.0766

+/-0.0984 Europium-155 U

0.0319

+/-0.0647 Lead-212 0.572

+/-0.0667 Lead-214 0.442

+/-0.101 Manganese-54 U

0.0197

+/-0.0261 Niobium-94 U

0.00763

+/-0.0221 Potassium-40 10.8

+/-1.02 Radium-226 0.459

+/-0.102 Silver-108m U

0.006

+/-0.020 Thallium-208 0.155

+/-0.0531 0.0698 0.0847 0.124 0.0331 0.0247 0.0203 0.0157 0.0498 0.0595 0.0602 0.0293 0.0361 0.018 0.0195 0.175 0.0331 0.0181 0.0197

+/-0.180

+/-0.103

+/-0.2 15

+/-0.102

+/-0.0377

+/-0.0342

+/-0.0209

+/-0.0548

+/-0.0984

+/-0.0647

+/-0.0667

+/-0.101

+/-0.0261

+/-0.0221

+/-1.02

+/-0.102

+/-0.020

+/-0.0531 0.155 0.178 0.278 0.0728 0.0539 0.0444 0.0374 0.107 0.135 0.126 0.0621 0.0776 0.0402 0.0424 0.409 0.0728 0.0391 0.043 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/20/06 0721 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-016E, Project:

YANKO 1204 Sample ID:

171454004 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time 'Vas exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was anaiyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING L.ABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com

/

of A

Certificate of AnalysiS, Company Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-017F 171454005 TS 24-AUG-06 12-SEP-06 Client 6.96%

Project:

YANK01204 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-I154 Europium-1 55 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Ut 0.00 U

-0.0302 0.556 0.521 U

0.024 U

0.00655 U

0.00225 U

0.013 U

-0.0237 U

0.030 0.601 0.620 U

0.00167.

U 0.0208 10.6 0.521 U -0.00771 0.191

+/-0.182

+/-0.110

+/-0.334

+/-0.117

+/-0.0288

+/-0.0301

+/-0.0229

+/-0.0697

+/-0.0778

+/-0.0653

+/-0.0679

+/-0.102

+-/-0.0245

+/-0.025

+/-1.00

+/-0.117

+/-0.0186

+/-0.0502 0.147 0.0903 0.130 0.0374 0.0261 0.0229 0.0195 0.0558 0.0626 0.0603 0.0291 0.0383 0.0216 0.0178 0.184 0.0374 0.0157 0,0183

+/-0.182

+/-0.110

+/-0.334

+/-0.117

+/-0.0288

+/-0.0301

+/-0.0229

+/-0.0697

+/-0.0778

+/-0.0653

+/-0.0679

+/-0.102

+/-0.0245

+/-0.025

+/-1.00

+/-0.117

+/-0.0186

+/-0.0502 0.309 0.188 0.289 0.0809 0.0565 0.0494 0.0446 0.118 0.140 0.126 0.0614 0.0816 0.047 0.0388 0.424 0.0809 0.034 0.040 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 0722 569467, 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021

,/

AXP2 09/12/06 1739 567633 The following Analytical Methods were performed Method Description I

EML HASL 300; 4.5.2.3 Notes:

The Qualifiers in this report ar6 defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-017F Project:

YANKO 1204 Sample ID:

171454005 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MVIDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis/

D Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis

/

Company:

Connecticut Yankee Atomic Powei Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 26, 2006 Client 2ample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-0188F 171454006 TS 24-AUG-06 12-SEP-06 Client 3.3%

Proeect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganina, Solid-FSS GAM & ALL FSS 226 ingrowth Waived Actinium-228 0.626

+/-0.156 Americium-241 U

0.0455

+/-0.108 Bismuth-212 0.382

+/-0.211 Bismuth-214 0.535

+/-0.077 Cesium-134 U

0.0227

+/-0.0191 Cesium-137 0.0361

+/-0.0215 Cobalt-60 U -0.00248

+/-0.0167, Europium-152 U

-0.0163

+/-0.0429 Europium-154 U

-0.0313

+/-0.0509 Europium-155 U

0.00434

+/-0.0492 Lead-212 0.659

+/-0.0724 Lead-214 0.656

+/-0.0864 Manganese-54 U

0.0109

+/-0.0162 Niobium-94 U

-0.0118

+/-0.0137 Potassium-40 10.4

+/-1.01 Radium-226 0.535

+/-0.077 Silver-108m U-0.000948

+/-0.0134 Thallium-208 0.212.

+/-0.0388 0.0447 0.0895.

0.0947 0.0231 0.0179 0.0139 0.0138 0.0373 0.0402 0.0439 0.021 0.0263 0.0127 0.0114 0.116 0.0231 0.0116 0.0144

+/-0.156

+/-0.108

+/-0.211

+/-0.077

+/-0.0191

+/-0.0215

+/-0,0167

+/-0.0429

+/-0.0509

+/-0.0492

+/-0.0724

+/-0,0864

+/-0.0162

+/-0,0137

+/-1.01

+/-0.077

+/-0.0134

+/-0.0388 0.0959 0.184 0.202 0.049 0.0378 0.0295 0.0301 0.0777 0.0871 0.0903 0.0433 0.0548 0.0271 0.0242 0.257, 0.049 0.0245 0.0303 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/20/06 0722 569467 1

Mt des'criptin I

F pc 1 hie full owing~~~~rc I

epJVttlIU er pr fl1 Method Description Analyst.

Date I nne AXP2 09/12/06 1739 567633 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 k

The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-018F Proiect:

YANK01204 SampleID:

171454006 ClientiD:

YANKOO0 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been clonfinned by GC/MS analysis D

Results are reportedfrom a diltuted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds 'spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamnma Spectroscopy--Uncertain identificationŽ'

X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samiiples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-004F 171454007 TS 25-AUG-06 12-SEP-06 Client 6.7%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bism uth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium, 154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.625 U

-0.178 0.550 0.550 U

0.0362 U

.0.0297 U

0.017 U -0.00823 U

0.0848 U

-0.0214 0.661 0.561 U -0.00978 U

0.00656 l1.5 0.550 U

0.00429 0.222

+/-0.130

+/-0.108

+/-0.210

+/-0.0874

+/-0.0261

+/-0.0232

+/-0.011

+/-0.056

+/-0.0746

+/-0.0621

+/-0.0612

+/-0.0893

+/-0.0219

+/-0.0286

+/-0.847;

+/-0.0874

+/-0.0202

+/-0.0447 0.0674 0.081 0.152 0.0412 0.0235 0.0198 0.0182 0.0472 0.0691 0.0552 0.0279 0.0338 0.018 0.0152

0. 166 0.0412 0.0172 0.0174

+/-0.130

+/-0.108

+/-0.210

+/-0.0874

+/-0.0261

+/-0.0232

+/-0.011

+/-0.C56

+/-0.0746

+/-0.0621

+/-0.0612

+/-0.0893

+/-0.0219

+/-0.0286

+/-0.848

+/-0.0874

+/-0.0202

+/-0.0447 0.145 0.167 0.324 0.0868 0.0501 0.0421 0.0404 0.0993

.0.149 0.114 0.0582 0.0712 0.0387 0.0326 0.372 0.0868 0.0363 0.0372 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 0723 569467 I

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1739 567633 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

l'.

Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-0045.*

Proiect:

YANK01204 Sample ID:

171454007 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batchý Mtd Result is greater than value reported A

The TIC is a suspected aidol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirri.ed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult'Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-004FS 171454008 TS 25-AUG-06 12-SEP-06 Client 4.18%

Project:

Client ID:

VoL Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-2281 0.771 Americium-241 U

-0.0196 Bismuth-212 0.565 Bismuth-214, 0.668 Cesium-134 U

0.00945 Cesium-137 U

0.0558 Cobalt-60 U 0.000294 Europium-152 U

0.0515 Europium-154 U

-0.08 Europium-155 U

-0.0366.

Lead-212 0.561 Lead-214 0.601 Manganese-54 U

0.00942 Niobium-94 U

-0.0202 Potassium-40 11.2 Radium-226 0.668 Silver-108m U -0.00614 Thallium-208 0.246

+/-0.237

+/-0.0434

+/-0.379

+/-0.149

+/-0.0395

+/-0.0628

+/-0.0343

+/-0.0793

+/-0.102

+/-0.0744

+/-0.092

+/-0.130

/-0.0343

+/-0.0312

+/-1.34

+/-0.149

+/-0.027

-/-0.0735 0.0932 0.0374 0.248 0.0532 0.0338 0.0283 0.0287 0.0704 0.0769 0.061 0.0497 0.0421 0.0294 0.0249 0.284 C.0532 0.0236 0.0299

+/-0.237

+/-0.0434

+/-0.379

+/-0.149

+/-0.0395

+/-0.0628

+/-0.0343

+/-0.0793

+/-0.102

+/-0.0744

+/-0.092

+/-0.130

+/-0.0343

+/-0.0322

+/-1.34

+/-0.149

+/-0.027

+/-0.0735 0.204 0.0776 0.529 0.114 0.0726 0.0608 0.0638 0.149 0.171 0.127 0.103 0.090 0.0634 0.0536 0.632 0.114 0.0503 0.0637 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 0723 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch D*y Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID-.

9530-0004-004FS Project:

YANK0 1204 Sample ID:

171454008 Client ID:

YANK001 Vol. Recv'.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blvaik BD Results are either below the MDC or tracer recovery is, low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed fo'., but not detected above the MIDL, MDA, or LOD.

UI Gamrna Spectroscopy--Uncertain identification

.X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Ih Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis. '

54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PC# 002332 Report Date:

September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-009F 171454009 TS 25-AUG-06 12-SEP-06 Client 8.71%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 P'arameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnina,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.796 Americium-241 U

-0.0113 Bismuth-212.

0.521 BismLIth-214.

0.432 Cesium-134 U

0.0114 Cesium-137 0.136

+

Cobalt-60 U

0.00715 4

Europium-152 U

-0.0617 Europiuni-154 U

0.00312 4

Europium-155 U

0.0766 4

Lead-212 0.736 4

Lead-214 0.496 Manganese-54 U

0.0083

+

Niobium-94 U

0.018 4

Potassium--40 10.7 Radium-226 0.432 Silver-108m U -0.00149

+

Thallium-208 0.216

+

+/-0.210

/-0.0322

+/-0.316

+/-0.102 V-0.0354

-/-0.0513

-/-0.0315

+/-0.066

-/-0.0772

-/-0.0734

+/-0.0739

+/-0.108

-/-0.0279

  • /-0.0244

+/-1.14

+/-0.102

/-0.0224

/-0.0547 0.0813 0.0269 0.162 0.0393 0.0303 0.0216 0.0271 0.0503 0.0649 0.0442 0.031 0.0415 0.0239 0.0221 0.229 0.0393 0.0196 0.0213

+/-0.210

+/-0.0322

+/-0.316

+/-0.102

+/-0.0354

+/-0.0513

+/-0.0315

+/-0.066

+/-0.0772

+/-0.0734

+/-0.0739

+/-0.108

+/-0.0279

+/-0.0244

+/-1.14

+/-0.102

+/-0.0224

+/-0.0547 0.180 0.0561 0.357 0.0855 0.0655 0.0472 0.0607 0.108 0.148 0.0929 0.0654 0.0883 0.6523 0.0478 0.524 0.0855 0.042 0.0464 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 0724 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description

/

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gelcom Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424/

Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-009F Project:

YANKO 1204 Sample ID:

171454009 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifer Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results ve rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-009FS 171454010 TS 25-AUG-06 12-SEP-06 Client 6.35%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Ml\\vtd Rad Gamma Spec Analysis Gainina,Solid-FSS GAM & ALL ESS 226 Ingrowth Waived Actinium-228 0.658 Americium-241 U

0.100 Bismuth-212 0.535 Bismuth-214 0.444

+

Cesium-134 U

0.0214 Cesium-137 0.111 4

Cobalt-60 U 0.000951 4

Europium-152 U -0.00693

+

Europium-154.

U 0.00194

+

Europium-155 U

0.00476

+

Lead-212 0.763 Lead-214 0.587

+

Manganese-54 U

-0.0147 4

Niobium-94 U

0.00168

+

Potassium-40 12.1 Radium-226 0.444

+

Silver-108m U

0.00543

+

Thallium-208 0.200

+/-0.175

+/-0.112

+/-0.217

/-0.0706

-/-0.0286

/-0.0364

  • /-0.0165

/-0.0462

/-0.0552

/-0.0574

+/-0.057 1-0.0729

./-0.0184

'/-0.0166

+/-0.774

/-0.0706

/-0.0153

+/-0.038 0.0526 0.090 0.110 0.0301 0.020 0.0153 0.0142 0.0402 0.0474 0.0512 0.0235 0.0274 0.0148 0.0145 0.146 0.0301 0.0135 0.0136

+/-0.175

+/-0.112

+/-0.217

+/-0.0706

+/-0.0226

+/-0.0364

+/-0.0165

+/-0.0462

+/-0.0552

+/-0.0574

+/-0.057

+/-0.0729

+/-0.0184

+/-0.0166

+/-0.774

+/-0.0706

+/-0.0153

+/-0.038 0.112 0.186 0.235 0.0634 0.0421 0.0324 0.0311 0.0841 0.102 0.106 0.0489 0.0576 0.0316 0.0305 0.320 0.0634 0.0283 0.0288 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g MJH1 09/20/06 0724 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Diy Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740.

567633 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-009FS Proiect:

YANK01204

'-:1trple ID:

171454010 Client ID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported froni a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits d) not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 2c 407 - (843) 556-8171 - www.gel~com,

'Certificate of Analysis Analvsis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Ham.npton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

9530-0004-013F Project:

YANKO 1204 Sample ID:

171454011 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

25-AUG-06 Receive Date:

12-SEP-06 Collector:

Client Moisture:

4.27%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batcih Mtd Rad Gamma Spec Analysis Ganuna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.590

+/-0.165 Americium-241 U

-0.0387

+/-0.0866 Bismuth-212 0.437

+/-0.306 Bismuth-214 0.487

+/-0.0886 Cesium-134 U

0.0249

+/-0.0242 Cesium-I 37 0.087

+/-0.0401 Cobalt-60 U

0.00393

+/-0.0215 Europium-152 U

0.0367

+/-0.0557 Europium-154 U

0.059

+/-0.0639 Europium-155 U

0.0356

+/-0.0609 Lead-212 0.666

+/-0.0695 Lead-214 0.516

+/-0.0796 Manganese-54 U -0.00266

+/-0.0215 Niobium-94 U

0.00307

+/-0.0188 Potassium-40 tO.8

+/-0.864 Radium-226 0.487

+/-0.0886 Silver-108m U

-0.0i25

+/-0.0183 Thallium-208 0.222

+/-0.0469 0.0542 0.0672 0.126 0.0359 0.0225 0.0171 0.0181 0.0502 0.0585 0.0543 0.028 0.0344 0.0182 0.0165 0.158 0.0359 0.0147 0.0163

+/-0.165

+/-0.0866

+/-0.306

+/-0.0886

+/-0.0242

+/-0.0401

+/-0.0215

+/-0.0557

+/-0.0639

+/-0.0609

+/-0.0695

+/-0.0796

+/-0.0215

+/-0.0188

+/-0.864

+/-0.0886

+/-0.0183

+/-0.0469 0.119 0.140 0.274 0.0764 0.0482 0.0368 0.0402 0.106 0.128 0.113 0.0586 0.0728 0.0392 0.0354 0.355 0.0764 0.0315 0.0351 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 0725 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description I

EML HASL 30Q,)4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-013F Project:

YANKO 1204 Sample ID:

171454011 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for,, but not detected above the MDL, MDA, or LOD..

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning.this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-OOIF 171454012 TS 25-AUG-06 12-SEP-06 Client 2.72%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.994

+/-0.222 Americium-241 U

0.116

+/-0.0935 Bismuth-212 0.613

+1-0.300 Bismuth-214 0.524

+/-0.110 Cesium-134 UI 0.00

+/-0.0359 Cesium-137 0.141

+/-0.0422 Cobalt-60 U

0.00817

+/-0.0252 Europium-152 U

-0.0137

+/-0.061 Europium-154 U

-0.0236

+/-0.0731 Europium-155 U

0.0822

+/-0.0931, Lead-212 0.912

+/-0.076 Lead-214 0.701

+/-0.0931 Manganese-54 U

0.0353

+/-0.0318 Niobium-94 U -0.00172

+/-0.0241 Potassium-40 13.3

+/-1.10 Radium-226 0.524

+/-0.110 Silver-108m U

-0,0112

+/-0.0199 Thallium-208 0.313

+/-0.0551 0.0757 0.0808 0.137 C.0351 0.0281 0.021 0.0223 0.0492 0.0596 0.0572 0.0308 0.0401 0.0234 0.0202 0.179 0.0351 0.0166 0.0194

+/-0.222

+/-0.0935

+/-0.300

+/-0. ICf

+/-0.035;

+/-0.0422

+/-0.0252

+/-0.061

+/-0.073

+/-0.0931

+/-0.076

+/-0.0931

+/-0.0318

+/-0.0241

+/-1.10

+/-0.110

+/-0.0199

+/-0.0551 0.165 0.168 0.30l 0.0757 0.0602 0.0453 0.050 0.105 0.134 0.119 0.0645 0.0846 0.0504 0.0433 0.412 0.0757 0.0356 0.0418 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g

,pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/26/06 0914 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Diy Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

September 26, 2006

Contact:

Mr.. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9 953 0-0004-001F Proiect:

YANK01204 Sample ID:

171454012 ClientID:

'YANKOO0 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Restilt is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-019F 171454013 TS 25-AUG-06 12-SEP-06 Client 2.88%

Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF' Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganina, Solid-FSS GAM & ALL FSS 226 hIgrowth Waived Actinium-228 0.430

+/-0.160 Americium-241 U

-0.0202

+/-0.0823 Bismuth-212 0.398

+/-0.280 Bismuth-214 0.290

+/-0.0746 Cesium-134 U

0.0205

+/-0.0258 Cesium-137 0.0965

+/-0.0401 Cobalt-60 U -0.00929

+/-0.0207 Europium-152 U

0.00784

+1-0.0355 Europium-I154 U

0.00677

+/-0.0641 Enropium--'155 U

-0.0223

+/-0.0537 Lead-212 0.441

+/-0.0603 Lead-214 0.366

+/-0.0751 Manganese-54 U

-0.017

+/-0.0193 Niobium-94 U

0.00684

+/-0.018 Potassium-40 10.2

+/-0.945 Radium-226 0.290

+/-0.074,*:

Silver-108m U

0.00949

+/-0.017 Thallium-208 0.151

+/-0.0441 0.0604 0.0699 0.139 0.0318 0.0212 0.0163 0.0163 0.0502 0.0559 0.0485

.0.027 0.0321 0.0147 0.0165 0.151 0.0318 0.0157 0.0183

+/-0.160

+/-0.0823

+/-0.280

+/-0.0746

+/-0.0258

+/-0.0401

+/-0.0207

+/-0.0555

+/-0,0641

+/-0.0537

+/-0.06C3

+/-0.0751

+/-0.0193

+/-0.018

+/-0.945

+/-0.0746

+/-0.017

+/-0.0441 0.133 0.146 0.302 0.0689 0.0461 0.0356 0.0375 0.106 0.125 0.102 0.0567 0.0684 0.0328 0.0356 0.349 0.0689 0.0336 0.0395 pCi/g

.pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi g pCi/g pCi/g MJHI 09/20/06 0959 569467 1

The following Prep Methods were performed Method Description Analyst

Date, Time

ýPrep Batch Dry Soil Prep Dry Soil Prep G*.-RAD-A-021 AXP2 09/12/05 1740 567633 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

&S5ls PO# 002332 Client Sample ID:

9530-0004-019F Project:

YANK01204 Sample ID:

1,71454013 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detecfed in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D - Results are reported fror;i a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U., Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 1njuil Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-015F 171454014 TS 25-AUG-06 12-SEP-06 Client 18.5%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.771 Americiuim-241 U

0.131 Bismuth-212 U

0.357 Bismuth-214 0.539 Cesium-134 U

0.0649

+

Cesium-137 U

0.0206

+

Cobalt-60 U 0.000588

+

Europium-152 U

0.00801

+

Europium-i 54 U

0.0179

+

Europium-155 U

0.0146

+

Lead-212 0.765 4

Lead-214 0.543 Manganese-54 U

0.0153

+

Niobium-94 U

-0.0097 4

Potassium-40 12.0 Radium-226 0.539 Silver-108m U -0.00849 Thallium-208 0.241

+

+/-0.213

+/-0.144

+/-0.446

+/-0.113

/-0.0596

/-0.0323

-/-0.0319

/-0.0822

/-0.0917

/-0.0701

/-0.0845

+/-0.116

-/-0.0318 4-0.0264

+/-1.25

+/-0.113

+/-0.026

  • /-0.0536 0.0715 0.0925 0.188 0.0438 0.032 0.0296 0.0273 0.0629 0.0808 0.0653 0.0388 0.0525 0.0283 0.0218 0.287 0.0438 0.0209 0.0306

+/-0.213

+/-0.144

+/-0.446

+/-0.113

+/-0.0596

+/-0.0323

+/-0.0319

+/-0.0822

+/-0.0917

+/-0.0701

+/-0.0845

+/-0.116

+/-0.0318

+/-0.0264

+/-1.25

+/-0.1 i13'

+/-0.026

+/-0.0536, 0.162 0.195 0.413 0.0953 0.0695 0.0636 0.0618 0.134 0.181 0.137 0.0816 0.1tI 0.0616 0.0477 0.646 0.0953 0.0452 0.0554 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pC i/g pCi/g pCi/g MJH1 09/20/06 0959 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description I

EML HASL 300; 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis

/

Company Connecticut Yankee Atomic Power Address 362 Injunl Hollow Rd East Hampton, Connecticut 06424 Repoqt Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO # 002332 Client Sample ID:

9530-0004-0 15F Project:

YANKO 1204 Sample ID:

171454014 ClientID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier.

Result Ui Rad Gamma Spec Analysis,-

Gamnmna,Solid-FSS CAM & ALL FSS 226 hngrowth Waived Actinium-228 0.890 Americium-241 U

0.111 Bismuth-212 0.448 Biismuth-214 0.451 Cesium-134 U

0.0322 Cesium-'137 -

0.276 Cobalt-60 U

0.00116 Europium-I152 U

0.0676 Europium-154 U -0.00709 Europium-155 U

0.0413 Lead-2l12 0.607 Lead-214 0.508 Manganese-54 U

0.0131 Niobium-94 tJ 0.0257 Potassium-40 13.2 Radium-226 0.451 Silver-108m U -0.00195 Thallium-208 0,219 9530-0004-002F 171454015 TS 25-AUG-06

[2-SEP-06 Client 5.87%

Proiect:

YANK01204 Client ID:

YANK001 Vol. Recv.:

ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.198

+/-0.0873

+/-0.402

+/-0.126

+/-0.0326

+/-0.0672

+/-0.0283

+/-0.0983

+/-0.0877

+/-0.0724

+/-0.0888

+/-0.113

+/-0.0253

+/-0.0306

+/-1.37

+/-0.126

+/-0.0249

+/-0.0576 0.0688 0.0723 0.173 0.0421 0.0304 0.0233 0.0236 0.0638 0.0721 0.0639 0.0355 0.0433 0.0229 0.0222 0.214 0.0421 0.021 0.0228

+/-0.198

+/-0.0873

+/-0.402

+/-0.126

+/-0.0326

+/-0.0672

+/-0.0283

+/-0.0983

+/-0.0877

+/-0.0724

+/-0.0888

+/-0.113

+/-0.0253

+/-0.0306

+/-1.37

+/-0.126

+/-0.0249

+/-0.0576 0.138 0.144 0.346 0.0841 0.0607 0.0465 0.0471 0.128 0.144 0.128 0.071 0.0865 0.0457 0.0443 0.428 0.0841 0.0419 0.0456 pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 1015 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424/

Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-002F Project:

YANKO 1204 Sample ID:

171454015 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MViDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MIDA, or LOD.

UI Gamma Spectroscopy -- Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: Scptember 2'6, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

N/nietlir.p 9530-0004-01 OF 171454016 TS 25-AUG-06 12-SEP-06 Client "A Q 0aT Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANKOO Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gaintna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228.

0.605 Americium-241 U

-0.0974 Bismuth-212 0.630 Bismuth-214 0.401 Cesium-134 U

0.0104 Cesium-137 0.0645 Cobalt-60 U

-0.0256 Europium-152 U-0.000691 Europium-154 U

-0.0228 Europiumn-155 U

0.0761 Lead-21,2 0.496 Lead-214 0.413 Manganese-54 U -0.00288 Niobium-94 U

0.00672 Potassium-40 9.33 Radium-226 0.401 Silver-108m U

-0.0011 Thallium-208 0.188

+/-0.177

+/-0,107

+/-0.244

+/-0.0943

+/-0.0277

+/-0.0395

+/-0.023

-/-0.0602

-/-0.0758

+/-0.0638

/-0.063,5

+/-0.105

/-0.0234

-/-0.0215

+/-0.944

-/-0.0943

+/-0.0193

-/-0.0533 0.0583 0,0835 0.127 0.0355 0.024 0.0221 0.0149 0.0535 0.0608 0.0609 0.0304 0.6356 0.0202 0.0187 0.173 0.0355 0.0168 0.0188

+/-0.177

+/-0.107

+/-0.244

+/-0.0943

+/-0.027/

+1-0.0395

+/-0.023

+/-0.0602

+/-0.0758

+/-0.0638

+/-0.0635

+/-0.105

+/-0.0234

+/-0.0215

+/-0.944

+/-0.0943

+/-0.0193

+/-0.0533 0.131 0.175 0.282 0.0771 0.0523 0.0478 0.0354 0.114 0.137 0.127 0.0641 0.0762 0.0443 0.0406 0.401 0.0771 0.0363 0.0409 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g

.pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 1000 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:,

9530-0004-010F Proiect:

YANKO1204 Sample ID:

171454016 Client ID.:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MBA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below'the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported fron) a diluted aliquot of the sample H

Analytical holding time :,vas exceeded J

Value is estimated N/A Spikerecovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:' September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-008F 171454017 TS 28-AUG-06 12-SEP-06 Client 26.2%

Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC

TPU, MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.765

+/-0.17^,,

Americium-241 U

0.00995

+/-0.135 Bismuth-212 0.632

+/-0.210 Bismuth-214 0.574

+/-0.0905 Cesium-134 U

0.0329

+/-0.0205 Cesium-137 0.144

+/-0.0344 Cobalt-60 U

0.00255

+1-0.0159 Europium-152 U

-0.0482

+/-0.040 Europium-154 U

0.0473

+/-0.0529 Europium-155 U

0.0687

+/-0.0585 Lead-212 0.880

+/-0.086 Lead-214 0.708

+/-0.0946 Manganese-54 U

-0.0109

+/-0.0181 Niobium-94 U

0.00688

+/-0.0143 Potassium -40 12.8

+/-1.08 Radium-226 0.574

+/-0.0905 Silver-108m U

0.00291

+/-0.0137 Thallium-208 0.279

+/-0.0431 0.0461 0.0866 0.0969 0.0241 0.0175 0.0154 0.0135 0.0335 0.0474 0.0418 0.0206 0.0252 0.013 0.013 0.102 0.0241 0.012 0.013

+/-0.172

+/-0.135

+/-0.210

+/-0.0905

+/-0.0205

+/-0.0344

+/-0.0159

+/-0.040

+/-0.0529

+/-0.0585

+/-0.086

+/-0.0946

+/-0.0181

+/-0.0143

+/-1.08

+/-0.0905

+/-0.0137

+/-0.0431 0.0975 0.177 0.204 0.0504 0.0365 0.032 0.0291 0.0694 0.100 0.0855 0.0423 0.0522 0.0274 0.0272 0.224 0.0504 0.025 0.0272

'pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pC i/g pCi/g pCi/g pCi/g pCi/g' pCi/g pCi/g MJHI 09/20/06 1000 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hamnpton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9*530-0004-008F Proiect:

YANKO 1204 Saaple ID:

171454017 ClientID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample resttlts are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LoD.

UI Gamma Spectroscopy--Uncertain identification X

ConsultCase Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Sahples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-007F 171454018 TS 28-AUG-06 12-SEP-06 Client 36.6%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.846 Americium-241 U

-0.0396 4

Bismuth-212 0.585 Bismuth-214 0.626 Cesium-134 U

0.0462 4

CCsium-137 0.353 Cobalt-60 U

-0.0191 4

Europium-152 U 0.000947

+

Europium-154 U -0.00356 Europium-155 U

0.034

-+

Lead-212 0.868 Lead-214 0.675

+

Manganese-54

'U 0.0216 Niobium-94 U

0.0126

+

Potassium-40 12.8 Radium-226 0.626 Silver-108m U

0.0121 Thallium-208 0.297

+

+/-0.200

-/-0.0954

+/-0.371

+/-0.103

/-0.0283

+/-0.051

/-0.0295

-/-0.062'1

+/-0.077

-/-0.0692

+/-0.101

-/-0.0989

-/-0.0239

/-0.0227

+/-1.19

+/-0.103

+/-0.022

/-0.0497 0.0729 0.0833 0.158 0.0384 0.0251 0.0192 0.0205 0.355 0.0644 0.0592 0.0305 0.0397 0.0221 0.0198 0.154 0.0384 0.0195 0.0194

+/-0.2300

+/-0.0954

+/-0.37.

+/-0.! 03

+/-0.0283

+/-0.051

+/-0.0295

+/-0.0631

+/-0.077

+/-0.0692

+/-0.101

+/-0.0989

+/-0.0239

+/-0.0227

+/-1.19

+/-0.103

+/-0.022

+/-0.0497 0.146 0.167 0.316 0.0767 0.0502 0.0384 0.0409 0.110 0.129 0.118 0.061 0.0793 0.0441

'0.0395 0.309 0.0767 0.039 0.0387 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g

'pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g M.HI 09/20/06 1016 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06.

1740 567633 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: Sep!embcr 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-007F Proiect:

YANKO 1204 SampleID:

171454018 Client ID:

YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gal.com Certificate of Analysis Company:'

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-005F 1.71454019 TS 28-AUG-06 12-SEP-06 Client 10.4%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MiDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamlna,Solid-FSS GAM & ALL FSS 226 hJgrowth Waived Actinium-228 0.548 Americium-241 U ' 0.00343 Bismuth-212 U

0.423 Bismuth-214

, 0.544 Cesium-134 U

0.0373 Cesium-137 0.199 Cobalt-60 U

0.0171 Europium-152 U

-0.028 Europium-154 U

0.131 Europium-155 U

0.045 Lead-2'12 0.637 Lead-214 0.638 Manganese-54 U

0.0337 Niobium-94 U

0.0338, Potassium-40 11.8 Radium-226 0.544 Silver-108m U

-0.024 Thallium-208 0.238

+/-0.247

+/-0.0421

+/-0.488

+/-0.137

+/-0.0393

+/-0.0648

+/-0.0295

+/-0.0891

+/-0.102

+/-0.085

+/-0.0767

+/-0.125

+1-0.034ý-'

+/-0.0313

+/-1.12

+/-0.137

+/-0.0254

+/-0.0663 0.104 0.0376 0.214 0.0473 0.0358 0.0261 0.0269 0.0655 0.0982 0.058 0.0392 0.0489 0.0317 0.029 0.192 0.0473 0.0211 0.0246

+/-0.247

+/-0.0421

+/-0.488

+/-0.137

+/-0.0393

+/-0.0648

+/-0.0295

+/-0.0891

+/-0.10 2

+/-0.085

+/-0.0767

+/-0.125

+/-0.0348

+/-0.0313

+/-1.12

+/-0.137

+/-0.0254

+/-0.0663 0.225 0.078 0.460 0.102 0.0765 0.0563 0.0599

  • 0.139 0.213 0.121 0.0818 0.103 0.0679 0.0617 0.445 0.102 0,0452 0.053 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/20/06 1001 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Diy Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description t

EN/ML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-005F Proiect:

YANKO 1204 Sample ID:

171454019 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Managerconcerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-020F 171454020 TS 06-SEP-06 12-SEP-06 Client 4.14%

Proiect:

Client ID:

Vol. Recv.:

YANK0 1204 YANK001

/

/

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Galmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.990

+/-0.192 Americium-241

'U -0.00407

+/-0.0306 Bismuth-212 0.842

+/-0.305 Bismuth-214 0.566

+/-0.0869 Cesium-134 UI 0.00

+/-0.041 Cesium-1 37 U -0.00736

+/-0.0229 Cobalt-60 U

-0.0279

+/-0.0241 Europium-152 U

0.00643

+/-0.0545 Europium-154 U

0.00909

+/-0.0838 Europium-155 Ut 0.00

+/-0.0823 Lead-212 0.878

+/-0.0665 Lead-214 0.514

+/-0.0885 Manganese-54 U

0.0197

+/-0.0264 Niobium-94 U

0.00189

+/-0.0209 Potassium-40 15.1

+/-1.11 Radium-226 0.566

+/-0.0869 Silver-108m U -0.00561

+/-0.0183 Thallium-208 0.284

+/-0.049 0.0712 0.0275 0.157 0.0366 0.0284 0.0191 0.0162 0.0474 0.0719 0.0429 0.0277 0.034 0.0238 0.0181 0.208 0.0366 0.0161 0.0181

+/-0.192

+/-0.0306

+/-0.305

+/-0.0869

+/-0.041

+/-0.0229

+/-0.0241

+/-0.0545

+/-0.0838

+/-0.0823

+/-0.0665

+/-0.0885

+/-0.0264

+/-0.0209

+/-1.11

+/-0.0869

+/-0.0183

+/-0.049 0.156 0.0569 0.339 0.0787 0.0606 0.0415 0.0376 0.101 0.158 0.0893 0.0581 0.0722 0.0512 0.039 0.467 0.0787 0.0345 0.0392 pCi/g pCiig pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 1001 569467 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1740 567633 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than ".,,alue reported 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connec-ut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-020F Project:

YANK01204 Sample ID:

171454020 Client.D:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded

.J Value is estimated N/A Spike recovery limits'do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

ConsultCase Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or pres,ýrvation holding time was exceeded The above sample is reported on a dry Weight basis.

78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: Scptember 26, 2006 Client Sample ID:

9530-0004-021F Project:

YANK01204 Sample ID:

171454021 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

06-SEP-06 Receive Date:

12-SEP-06 Collector:

C!ient Moisture:

8.77%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.966

+/-0.205 Americium-241 U

0.0256

+/-0.0283 Bismuth-212 0.535

+/-0.397 Bismuth-214 0.783

+/-0.136 Cesium-134 U

0.0136

+/-0.049 Cesium-137 U

0.00736

+/-0.03 i5 Cobalt-60 U

-0.0106

+/-0.0307 Europium-152

U

-0.0362

+/-0.0681 Europium-154 U

-0.0783

+/-0.125 Europium-155 U

0.0611

+/-0.0653 Lead-2t2 0.866

+/-0.084 Lead-214 0.680

+/-0.118 Manganese-54 U

0.0469

+/-0.043 Niobium-94 U -0.00108

+/-0.0287 Potassium-40 14.8

+/-1.27 Radium-226 0.783

+/-0.136 Silver-108m U

0.0177

+/-0.0238 Thallium-208 0.316

+/-0.0603 0.0841 0.034 0.194 0.0473 0.0312 0.0271 0.0242 0.058 0.0796 0.0609 0.0357 0.0442 0.026 0.024 0.216 0.0473 0.022 0.0234

+/-0.205

+/-0.0283

+/-0.397

+/-0.136

+/-0.049

+1-0.0315

+/-0.0307

+/-0.0681

+/-0.125

+/-0.0653

+/-0.084

+/-0.118

+/-0.043

+/-0.0287

+/-1.27

+/-0.136

+/-0.0238

+/-0.0603 0.186 0.0705 0.422 "0.102 0.0674 0.0584 0.055 0.124 0.1771 0.127 0.0749 0.0939 0.0566

.0.0517 0.499 0.102 0.047 0.0507 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi!g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 1010 569468 1

The following Prep Methods were performed Method Description' Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-021F Project:

YANKO 1204 Sample ID:

171454021 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD. Results are either below the MDC or tracer recovery is low.

C Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424/

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:.

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-022F 171454022 TS 06-SEP-06 12-SEP-06 Client 7.69%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnna,Solid-FSS GAM & ALL FSS 226 higrowth Waived Actinium-228 0.679 Americiurn-241 U

-0.0588 Bismuth-212 0.418 Bismuth-214 0.495 Cesium-134 U

0.0355 Cesium-137 0.0522 Cobalt-60 U

0.018 Europium-152 U

-0.0118 Europium-154 U

0.0339 Europium-155 U

0.0842 Lead-212 0.786 Lead-214 0.611 Manganese-54 U -0.00196 Niobium-94 U

0,0065 Potassium-40 13.7 Radium-226 0.495 Silver-108m U

0.00245 Thallium-208 0.242

+/-0.115

+/-0.0964

+/-0.169

+/-0.0633

+/-0.0227

+/-0.0292

+/-0.0138

+/-0.0409

+/-0.0443

+/-0.0521

+/-0.0479

+/-0.060

+/-0.0164

+/-0.0152

+/-0.731

+/-0.0633

+/-0.0128

+/-0.0392 0.0429 0.0777 0.104 0.0236 0.0175 0.0131 0.0145 0.035 0.0499 0.0452 0.0226 0.0211 0.0138 0.0136 0.128 0.0236 0.0118 0.0122

+/-0.115

+/-0.0964

+/-0.169

+/-0.0633

+/-0.0227

+/-0.0292

+/-0.0138

+/-0.0409

+/-0.0443

+/-0.0521

+/-0.0479

+/-0.060

+/-0.0164

+/-0.0152

+/-0.731

+/-0.0633

+/-0.0128

+/-0.0392 0.0923 0.161 0.220 0.0498 0.0369 0.0277 0.0316 0.0729 0.107 0.0929 0.0465 0.0445 0.0293 0.0286 0.280 0.0498 0.0248 0.0258 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/20/06 1056 569468 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil ir-ep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - Www.gel.com Certificate of Analysis Company :. Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-022F Project:

YANK01204 Sample ID:

171454022 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted, aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds soi.ke corcentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package; or Proj,:'t Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL hi Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

82

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Co3nnecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East, Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26. 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-023F 171,454023 TS 06-SEP-06 12-SEP-06 Client 5.66%

Proiect:

Client ID:

Vol. Recv.:

YANK0 204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganuna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.749 Americium-241 U

-0.0538 Bismuth-212 0.542 Bismuth-214 0.504 Cesium-134 U

0.0448 Cesium-137 U

0.026 Cobalt-60 U -0.00303 Europium-152 U

-0.0121 Europium-154 U

-0.0253 Europium-155 U

0.0206 Lead-212 0.687 Lead-214 0.656 Manganese-54 U

0.0201 Niobium-94 U -0.00284 Potassium-40 14.1 Radium-226 0.504 d

Silver-108m U 0.000829 Thallium-208 0.247 d

+/-0.176

+/-0.102

+/-0.296

+/-0.0933

+/-0.0345

+/-0.0241

+/-0.0223

+/-0.0529

+/-0.0789

+/-0.0609

+/-0.0668

+/-0.0861

/-0.0221

/-0.0204

+/-1.05

+/-0.0933

/-0.0193

/-0.0447 0.0624 0.087 0.163 0.0338 0.0259 0.0212 0.0187 0.0481 0.0652 0.0584 0.0301 0.0376 0.0207 0.0174 0.125 0.0338 0.0176 0.0146

+/-0.176

+/-0.102

+/-0.296

+/-0.0933

+/-0.0345

+/-0.0241

+/-0.0223

+/-0.0529

+/-0.0789

+/-0.0609

+/-0.0668

+/-0.0861

+/-0.0221

+/-0.0204

+/-1.05

+/-0.0933

+/-0.0193

+/-0.0447 0.138 0.181 0.351 0.0731 0.0557 0.0456 0.0424 0.103 0.144 0.121 0.0631 0.0797 0.0449 0.0377 0.301 0.0731 0.0375 0.0322 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pcCi/g pCi/g pCi/g

,pCi/g pCi/g pCi/g pCi/g pCi/g MJHl1 09/20/06 1056 569468 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method.

Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 83

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-023F Project:

YANKO 1204 Sample ID:

171454023 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analy;:,,d for, but not detected above the MDL, MDA, or LOD.

-UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager':.oncerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations a-e <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

84

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Sbils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-024F 1,71454024 TS 06-SEP-06 12-SEP-06 Client 9.7%

Proiect:

YANK0 1204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date

-Time Batch Mid Rad Gamma Spec Analysis Gaimna, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.670

+/-0.118 Americium-241

'1 0.0803

+/-0.0798 Bismuth-212 0.494

+/-0.221 Bismuth-214 0.572

+/-0.0706 Cesium-134 UI 0.00

+/-0.0341 Cesium-137 0.049

+/-0.0304 Cobalt-60 U

0.00553

+/-0.0184 Europiuim-152 U

-0.0199

+/-0.0549 Europium-154 U

0.0442

+/-0.0541 Europium-155 U

0.0247

+/-0.0508 Lead-212 0.687

+/-0.0494 Lead-214 0.630

+/-0.0725 Manganese-54 U

-0.0082

+/-0.0177 Niobium-94 U

0.0136

+/-0.0162 Potassium-40 14.0

+/-0.793 Radium-226 0.572

+/-0.0706 Silver-108m U

-0.005

+/-0.0186 Thallium-208 0.254

+/-0.0383 0.0512 0.0694 0.115 0.0285 0.0199 0.0159 0.0158 0.0405 0.0486 0.0477 0.0286 0.0294 0.0147 0.0149 0.111 0.0285 0.0135 0.0143

+/-0.118

+/-0.0798

+/-0.221

+/-0.0706

+/-0.0341

+/-0.0304

+/-0.0184

+/-0.0549

+/-0.0541

+/-0.0508

+/-0.0494

+/-0.0725

+/-0.0177

+/-0.0162

+/-0.793

+/-0.0706

+/-0.0186

+/-0.0383 0.109 0.142 0.243 0.0598 0.0418 0.0336 0.0342 0.0842 0.104 0.0978 0.0587 0.0612 0.0312 0.0313 0.248 0.0598 0.0283 0.0301 pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/20/06 1057 569468 1

The following Prep Methods were performed Method Description Analyst Date Time

- Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than *alue reported 85

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:.

9530-0004-024F Project:

YANK01204 Sample ID:

171454024 Client ID:

YANK001 Vol. Recv.:

Parameter ZQualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated bla,ýPtk BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or mon, R

Sample results are rejecte.d U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X'

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

86

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PK# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-025F 171454025 TS 06-SEP-06 12-SEP-06 Client 8.56%

Project:

YANK01204 ClientID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, SoliM-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.917

+/-0.201 Americium-241 U

0.0399

+1-0.0544 Bismuth-212 U

0.0646

+/-0.280 Bismuth-214 0.545

+/-0.108 Cesium-134 U

0.0346

+/-0.0448 CCsium-137 U

0.0204

+/-0.0228 Cobalt-60 U -0.00485

+/-0.0206 Europium-152 U

0.0381

+/-0.0534 Europium-154 U

0.0369

+/-0.0721 Europium-155 U

0.00414

+/-0.0562

.Lead-212 0.689

+/-0.0963 Lead-214 0.604

+/-0.103 Manganese-54 U

-0.0148

+/-0.0219 Niobium-94 U

0.0153

+/-0.0238 Potassium-40 13.3

+/-1.33 Radium-226 0.545

+/-0.108 Silver-108m U

0.0103

+/-0.0186 Thallium-208 0.254

+/-0.0559 0.0584 0.0515 0.126 0.0351 0.0259 0.0217 0.0163 0.0497 0.0638 0.0497 0.0391 0.0366 0.0178 0.0173 0.146 0.0351 0.0169 0.0156

+/-0.201

+1-0.0544

+/-0.280

+/-0.108

+/-0.0448

+/-0.0228

+/-0.0206

+/-0.0534

+/-0.0721

+/-0.0562

+/-0.0963

+/-0.103

+/-0.0219

+/-0.0238

+/-1.33

+/-0.108

+/-0.0186

+/-0.0559 0.129 0.107 0.276 0.0754 0.0554 0.0464 0.0372 0.105 0.140 0.104 0.0809 0.0773 0.0388 0.0372 0.338 0.0754 0.036 0.0339 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/20/06 1057 569468 1

The following Prep Methods were performed Method Description Anal'st Date Time Prep Batch Diy Soil Prep Dry Soil Prep GL-RAD-A-021 AXF2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 87

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com' Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:

September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-025F Proiect:

YANKO 1204 Sample ID:

171454025 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspe;cted aldol-coridensation product B

Target analyte was detected in the associated blank-BD Results are either below the MDC or tracer recovery "s low C

Analyte has been confirmed by GC/MS analysis i

D Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample co:;i2entrat;cn exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X

ConsultCase Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/--RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported 6n a dry weight basis.

88

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

September 26, 2006 Client Sample ID:

SampleID:

Matrix:

CollectDate:

Receive Date:

Collect6r:

Moisture:

9530-0004-012F 171454026 TS 25-AUG-06 12-SEP-06 Client 13%

Project:

YANKO 1204 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americjium-241 U -0.00141 Curium-242 U -0.00764 Curium-243/244 U

0.0664 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

-0.0258 Plutonium-239/240 U

-0.106 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

-1.86 Rad Gamma Spec Analysis Ganuna,,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.997 Americium-241 U -0.00476 Bismuth-212 0.556 Bismuth-214 0.631 Cesium-134 U

0.0353 Cesium-137 U

0.038 Cobalt-60 U -0.00113 Europium-152 U

0.0468 Europium-.154 U -0.00539 Europium-155 U

0.127 Lead-212 0.958 Lead-214 0.690 Manganese-54 U

0.0384 Niobium-94 U

0.0189 Potassium-40 16.6 Radium-226 0.631 Silver-108m U -0.00385 Thallium-208 0.280 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U

-0.0242 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U

2.19

+/-0.0569

+/-0.0642

+/-0.102 0.00 0.0286 0.0452

+/-0.0571

+/-0.0642

+/-0.102

+/-0.128 0.120

+/-0.128

+/-0.0627 0.120 +/-0:0638

+/-9.82 8.32

+/-9.82

+/-0.226

+/-0.0957

+/-0.325

+/-0. 102

+/-0.0271I

+/-0.0401

+/-0.0236

+/-0.0609

+/-0.0755 F/-0.0761I

ý/-0.0833

+/-0.0985 F/-0.0471I F/-0.0226

+/-1.01

+/-0. 102 F-/-0.0 186 F/-0.0549 0.0716 0.0754 0.156 0.040 0.0255 0.0198 0.0192 0.0495 0.0617 0.070 0.0323 0.0348 0.0191 0.0174 0.134 0.040 0.0155 0.0224

+/-0.226

+/-0.0957

+/-0.325

+/-0.102

+/-0.0271

+/-0.0401

+/-0.0236

+/-0.0609

+/-0.0755

+/-0.0761

+/-0.0833

+/-0.0985

+/-0.0471

+/-0.0226

+/-1.01

+/-0.102

+/-0.0186

+/-0.0549.

0.0787 0*143 0.169 0.349 0.348 17.4 0.154 0.157 0.335 0.0847 0.0541 0.0423 0.0424 0.105 0.134 0.145 0.0674 0.0736 0.0412 0.0373 0.309 0.0847 0.0331 0.0474 0.0386 8.02 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g JASI 09/15/06 1152 567824 1

JASI 09/16/060952,567825 2

JASI 09/17/06 0602 567826 3

MJHI 09/20/06 1057 569468 4

KSDI 09/16/06 1622 567998 5

ATH2 09/17/06-0458 567994 6

+/-0.0181 0.0175 +/-0.0181

+/-4.65 3.78

+/-4.65 89

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171-- www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID:

9530-0004-012F 171454026 Proiect:

YANKO 1204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon-14 U

0.0855

+/-0.0887 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

-17.7

+/-47.3 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-3.36

+1-5.39 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.167

+/-0.285 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0701 +/-0.0887 0.148 32.9

+/-47.3 68.4 4.63

+/-5.39 9.58 0.235

+/-0.285 0.483 pCi/g pCi/g pCi/g pCi/g AXD2 09/14/06 t155 567937 8

MXPI 09/19/06 1335 567933 9

MXPI 09/16/06 1036 567934 10 KXRI 09/23/06 1040 567935 11 The following Prep Methods were performed Method Descriptior.

Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I 1-RC Modified 3

DOE EML HASL-300, Pu-I I-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA 906.0 Modified 8

EPA EERF C-01 Modified 9

DOE RESL Fe-1, Modified 10 DOE RESL Ni-l, Modified II DOE EML HASL-300, Tc-02-RC Modified 12 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery %

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Canrier/Tracer Recovery Alphaspec Am24l, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu24 1, Solid-ALL Fý GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS 101 80 95 77 69 (15%-t25%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

90

GENERAL"ENGiNEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID:

Sample ID: :

9530-0004-012F 171454026 Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 96 82 (25%-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 9

Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Co-icentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

91.

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: September 26, 2006 Client Sample ID.:

Samiple ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9530-0004-002F 171454027 TS 23-AUG-06 12-SEP-06 Client 8.88%

Proeect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty

'LC TPU IVID)A Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec An241, Cm, Solid ALL FSS Americium-241 U -(

Curium-242 U

Curium-243/244 U

0.0 0.

0881 0.00 0279 1.123 0307

+/-0.0429

+/-0.0778

+/-0.0741 0.0466 0.00 0.033

+/-0.0429

+/-0.0778

+/-0.0741 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

-0 Plutonium-239/240 U

-0.

Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Waived Actinium-228 Americium-241 U

(

Bismuth-212 Bismuth-214 Cesium-134 UI Cesium-137 Cobalt-60 U

0.0 Europium-I 52 U

-0.

Europium-1 54 U

Europium-155 U

0.

Lead-212

(

Lead-214 Manganese-54 U

-(

Niobium-94 U

0.0 Potassium-40 Radium-226 Silver-108m U

-0.

Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U

0.0 Rad Liquid Scintillation Analysis LSC, Tritiumn Dist, Solid-HTD2,ALL FSS Tritium U

-I

+/-0.0602 0.115 +/-0.0615

+/-0.0301 0.0574 +/-0.0302 4.29

+/-11.0 9.02

+/-11.0 Ingrowth

+/-0.211

+/-0.105

+/-0.396

+/-0.111

+/-0.0395

+/-0.0494

+/-0.0253

+/-0.0668

+/-0.089

+/-0.0655

+/-0.0812

+/-0.118

+/-0.029

+/-0.0237

+/-1.14

+/-0.111

+/-0.022

+/-0.058 0.0717 0.0909 0.146 0.0415 0.0289 0.0207 0.0214 0.0536 0.0571 0.0602 0.032 0.0378 0.0219 0.0202 0.143 0.0415 0.0185 0.0219

+/-0.211

+/-0.105

+/-0.396

+/-0.111

+/-0.0395

+/-0.0494

+/-0.0253

+/-0.0668

+/-0.089

+/-0.0655

+/-0.0812

+/-0.118

+/-0.029

+/-0.0237

+/-1.14

+/-0.111

+/-0.022

+/-0,058

.0.193 0.108 0.166 0.316 0.201 18.9 0.157 0.190 0.318 0.0886 0.0617 0.0447 0.0481 0.114 0.129 0.125 0.0669 0.0802 0.0475 0.0434 0.339 0.0886 0.0394 0.0468 0.0307 9.55 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g JASI 09/15/06 1152 567824 1

JAS1 09/16/06 0952 567825 2

JASI 09/17/06 0618 567826 3

MJHI 09/20/06 1732 569468 4

KSDI 09/16/06 1622 567998 5

ATH2 09/17/06 2009 567994 6

+/-0.0171 0.0137 +/-0.0171

+/-5.38 4.53

+/-5.38 92

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

Sample ID:

Report Date: September26, 2006 9530-0004-003F 171454027 Project:

Client ID:

Vol. Recv.:

YANK01204 YANKOO0 Parameter Qualifier Rad Liquid Scintillation Analysis Liquid Scint C04, Solid All, FSS Carbon-14 U

Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mtd 0.0578

+/-0.0876 0.0705 +/-0.0876 0.149

-12

+/-48.0 33.3

+/-48.0 69.2 pCi/g pCi/g pCi/g pCi/g AXD2 09/14/06 1433 567937 8

MXPI 09/19/06 1352 567933 9

MXPI 09/16/06 1107 567934 10 KXRI 09/23/06 1056 567935 11 0.394

+/-6.74 5.65

+/-6.74 11.7

-0.00867

+/-0.282 0.237

+/-0.282 0.487 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 09/12/06 1713 567634 The following Analytical Methods were performed Method Description 1

2 3

4 5

6 7

8 9

10 II 12 DOE* EMLc rHAS-300, Arm-05-AC IV~oljl~eud DOE EMN< iHASL-300, Pu-I1-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 906.0 Modified EPA 906.0 Modified EPA EERF C-0I Modified DOE RESL Fe-I, Modified DOE RESL Ni-l, Modified DOE EMIL HASL-300, Tc-02-RC Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery CatTier/Tracer Recovery Cal'ier/Tracer Recovery Test Recovery %

Acceptable Limits Atphaspec Am241, Cm, Solid ALL 70 (t5%-125%)

Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Liquid Scint Pu241, Solid-ALL FS 83 (25%-125%)

GFPC, Sr9O, solid-ALL FSS 83 (25%-t25%)

Liquid Scint Fe55, Solid-ALL FS 67 (15%-125%)

93

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9530-0004-003F Proiect:

YANK01204 Sample ID:

171454027 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 85 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS I

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirnmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

94

QUALITY CONTROL DATA L

95

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel com QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Reoort Date: September 26, 2006 Page 1 of 12 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

171454 Parnianie NOM

-Samiple Qual4 OC Units RPD%

REC %

Range Anlst Date Time Rad Alpha Spec Batch 567824 QC1201181598 Americitir-24 I Cuiriur-242 Curium-243/244 QC1201 181600 Ainericiurn-24 1 171450001 DUP u

0.0224 Uncert:

+/-0.0562 TPU:

+/-0.0563 U

0.029 Uncert:

+/-0.0568 TPU:

+/-0.0569 u

0.0152 Uncert:

+/-0.0812 TPU:

+/-0.0812 LCS Curium-242 Curium-243/244 QC1201181597 Americium-241 Curium-242 Curium-243/244 QC1201181599 Amncricium-24 1 Curium-242 Curium-243/244 9.83 Uncert:

TPU:

Uncert:

TPU:

11.9 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0344

+/-0.0558

+/-0.0558 U

0.00

+/-0.0576

+/-0.0576 U

-0.0054

+/-0.060

+/-0.060 9.33

+/-0.996

+/-1.40 U

0.092

+/-0.112

+/-0.113 10.9

+/- 1.08

+/-1.58 U

-0.0214

+/-0.0709

+/-0.0711 U

0.019

+/-0.0757

+/-0.0757 U

0.00145

+/-0.0787

+/-0.0787 pCi/g 947 pCi/g 200 pCi/g 420 pCi/g (0% - 100%) JASI (0%- 100%)

(0%- 100%)

95 (75%-125%)

MB 09/19/06 08:08 pci/g-PCi/g pCi/g pCilg pCi/g pCilg PCilg pCilg 92 (75%-125%)

09/15/06 11:52 Uncert:

TPU:

171450001 MS 13.0 U

0.0224 Uncert:

+/-0.0562 TPU:

+/-0.0563 U

0.029 Uncert:

+/-0.0568 TPU:

+/-0.0569 15.7 U

0.0152 Uncert:

+/-0.0812 TPU:

+1-0.0812 U

12.3

+/-1.24

+/-1.79

-0.0661

+/-0.0458

+/-0.0463 17.3

+/-1.46

+/-2.33 95 (75%-125%)

09/19/06 08:08 110 (75%-125%)

Batch 567825 QC1201181602 171450001 DUP Plutonium-238 U

-0.00319 U

-0.0577 pCi/g 179 (0% - 100%) JASI 09/16/06 09:52 96

GENERAL ENGINEERING LABORATORIES, LLCG, 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

171454 Page 2 of 12 Parmnanme NOM Saninle Oual QC Units RPD%

REC%

Range AnIst Date Time Rad Alpam Spec Rad Alpha Spec Batch 567825 Plutonium-239/240 QC1201181604 LCS Plutonium-238 Plutoniunm-239/240 QC1201181601 MB Plutortiumn-238 Plutonium-239/240 QC1201181603 171450001 MS Plutonium-238 Uncert:

+/-0.174 TPU:

+/-0.174 u

-0.0638 Uncert:

+/-0.132 TPU:

+/-0.132 Uncert:

TPU:

9.08 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0594

+/-0.0597 U

-0.024

+/-0.0868

+/-0.0868 U

0.0415

+/-0.0777

+/-0.0779 7J2

+/-0.872

+/-1.16 U

-0.0876

+/-0.107

+/-0.108 U

0.00165

+/-0.0898

+/-0.0898 pCi/g 91 (0%- 100%)

(75%-125%)

pCilg pCilg pCi/g pCi/g-pCi/g pCi/ýg 09/16/06 09:52 78 (75%-125%)

09/16/06 09:52 Plutonium-239/240 Batch 567826 Uncert:

TPU 12.0 Uncert:

TPU:

Uncert:

TPU:

U

-0.00319

+/-0.174

+/-0.174 U

-0.0638

+/-0. 132

+/-0.132 U

626

+/-11.5

+/-11.5 U

U,

_v.

QC1201181606 Plutonium-241 QC1201181608 Plutonium-241 171450001 DUP 1

-0.0197

+/-0.0981,

+/-0.0981 10.3,

+/-1.11

+/-1.53'

-8.24

+/-11.0

+/-11.0 112

+/-16.4

+/-20.0 86 (75%-125%)

(75%- 125%)

09/16/06 09:52 pCi/g 0

(0%- 100%) JASI I.CS 127 Uncert:

TPU:

QC1201181605 MB Plutonium-241 QC1201181607 171450001 MS Plutonium-241 Rad Gamma Spec Batch 569467 QC1201185426 171454001 DUP Actinium-228 Uncert:

TPU:

138 u

Uncert:

TPU:

U

-2.99

+/-11.0

+/-11.0 pci/g-pCi/g pCi/g 88 (75%-125%)

76 (75%-125%)

09/17/06 07:23 09/17/06 07:55 09/17/06 07:07 09/17/06 07:39 6.26

+/-11.5

+/-11.5 104

+/-14.0

+/-17.1 0.490

+/-0.141 Uncert:

0.519

+/-0.181

+/-0.181 pCi/g 6

(0%- IQO%) MJHI 09/20/06 10:17 97

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

171454 Page 3 of 12 Parmnamne NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 569467 Americium-241 Bismuth-212 B ismuth-2 14 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.141 U

0.112 Uncert:

+/-0.121 TPU:

+/-0.121 u

0.163 Uncert:

+/-0.172 TPU:

+/-0..!72 0.348 Uncert:

+/-0.081 TPU:

+/-0.081 U

0.0339 Uncert:

+/-0.0 17 TPU:

+/-0.017 0.0796 Uncert:

+/-0.0245 TPU:

+/-0.0245 U

0.00766 Uncert:

+/-0.0254 TPU:

+/-0.0254 U

0.000266 Uncert:

+/-0.0528 TPU:

+/-0.0528 U

0.0642 Uncert:

+/-0.080 TPU:

+/-0.080 UI 0.00 Uncert:

+/-0.100 TPU:

+/-0.100 0.465 Uncert:

+/-0.0565 TPU:

+/-0.0565 0.417 Uncert:

+/-0.0853 TPU:

+/-0.0853 U

0.0199 Uncert:

+/-0.019 TPU:

+/-0.019 U

0.016 Uncert:

+/-0.0153 TPU:

+/-0.0153 9.54 Uncert:

+/-0.855 TPU:

+/-0.855 0.348 Uncert:

+/-0.081 TPU:

+/-0.081 U

-0.0181 Uncert:

+/-0.0169 U

0.023'

+/-0.0494'

+/-0.0494 0.569

+/-0.253

+/-0.253 0.318

+/-0.106

+/-0.106 U

0.0279

+/-0.0273

+/-0.0273 0.0997

+/-0.0486

+/-0.0486 U

0.00572

+/-0.0393

+/-0.0393 U

-0.00373

+/-0.08j3

+/-0.0873 U

-0.00757

+/-0.0872

+/-0.0872 U

-0.0133

+/-0.0587

+/-0.0587 0.532

+/-0.078

+/-0.078 0.402

+/-0.107

+/-0.107 U

0.0314

+/-0.0152

+/-0.0152 U

0.00458

+/-0.023

+/-0.023 7.35

+/-0.957

+/-0.957 0.318

+/-0.106

+/-0.106 U

-0.00342

+/-0.0221 pCi/g 132 pCi/g 1.11 pCi/g 9

pCi/g 19 Lead-212 Lead-214 pCi/g 22 pCi/g 29 pCi/g 231 pCi/g 254 pCi/g 236 pCi/g 13 pCi/g 4

pCi/g 45 pCi/g 111 pCi/g 26*

pCi/g 9

pCi/g 136 (0%- 100%)

(0%- 100%)

(o%-

0oo%)

(0%- 100%)

(0o-- 100%)

(0% - i00%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%-20%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

(0% - 20%)

(0% - 100%)

(0%- 100%)

Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 98

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

171454 Parmname Rad Gamma Spec Batch 569467 Thallium-208 QC1201185427 LCS Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-I 52 1

Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Sample Oual OC Page 4 of 12 REC%

Range AnIst Date Time NOM Units RPD%

TPU:

Uncert:

TPU:

Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.57 Unceft:

TPU:

14.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0169 0.150

+/-0.0344

+/-0.0344

+/-0.0221 0.196

+/-0.0614

+1-0.0614 U

-0.268

+/-0.809

+/-0.809 27.3

+/-2.24

+/-2.24 U

1.83

+/-1.37

+/-1.37 U

-0.0223

+/-0.333

+/-0.333 U

-0.0463

+/-0.194

+/-0.194 10.9

+/-1.16

+/-1.16 15.6

+/-0.830

+/-0.830 UJ 0.0299

+/-0.355

+/-0.355 U

0.155

+/-0.383

+/-0.383 U

0.312

+/-0.288

+/-0.288 U

-0.036

+/-0.187

+/-0.187 U

0.173

+/-0.264

+/-0.264 U

0.167

+/-0.195

+/-0.195 U

0.0488

+/-0.161

+/-0.161 U

0.285 pCi/g 27 (0% - 100%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 09/20/06 07:46 117 (75%-125%)

114 (75%-125%)

108 (75%-125%)

99

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

171454 Page 5 of 12 Parnmame NOM Sample Oual QC Units RPD%

REC %

Range AnIst Date Time Rad.Gamina Spec Batch 569467 Radium-226 Silver-108m Thalliurn-208 QCI201185425 Actinium-228 Americium-241 MB Bismuth-212 BismuIth-214 Cesium-134 Cesium-137 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:ý TPU:

+/-1.48

+/-1.48 U

-0.0223

+/-0.333

+/-0.3331, lU 0.0663

+/-0.148'

+/-0.148 U

-0.0912

+/-0.189

+/-0.189 U

0.0416

+/-0.0452

+/-0.0452 U

-0.081

+/-0.0804

+/-0.0804 U

-0.0379

+/-0.0881

+/-0.0881 U

0.0442

+/-0.0324

+/-0.0324 U

0.000607

+/-0.0119

+/-0.01 19 U -7.090E-05

+/-0.0117

+/-0.0117 U

-0.00242

+/-0.0107

+/-0.0107 U

0.0294

+1-0.0328

+/-0.0328 U

0.00616

+/-0.0372

+/-0.0372 U

-0.0165

+1-0.0359

+1-0.0359 U

0.0183

+/-0.0297

+/-0.0297 U

0.0306

+/-0.0253

+/-0.0253 pCi/g pCi/g pCi/g pCi/g PC /i" pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 09/20/06 10:02 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 100

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary.

Workorder:

171454 Page 6 of 12 REC%

Range AnIst Date Time Parmnanme NOM Sample Qual QC Units RPD%

Rad Gamma Spec Batch 569467 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Batch 569468 QCI201185429 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-54 Europium-155 171454021 DUP 0.966 Uncert:

+/-0.205 TPU:

+/-0.205 U

0.0256 Uncert:

+/-0.0283 TPU:

+/-0.0283 0.535 Uncert:

+/-0.397 TPU:

+/-0.397 0.783 Uncert:

+/-0.136 TPU:

+/-0.136 u

0.0136 Uncert:

+/-0.049 TPU:

+/-0.049 U

0.00736 Uncert:

+/-0.0315 TPU:

+/-0.0315 U

-0.0106 Uncert:

+/-0.0307 TPU:

+/-0.0307 U

-0.0362 Uncert:

+/-0.0681 TPU:

+/-0.0681 U

-0.0783 Uncert:

+/-0.125 TPU:

+/-0.125 U

0.0611 U

0.00138

+/-0.0123

+/-0.0123 U

0.00583

+/-0.0111

+/-0.0111 U

0.0485

+/-0.132

+/-0.132!

U 0.0442

+/-0.0324

+/-0.0324 U

0.00287

+/-0.012

+/-0.012 U'

0.00554

+1-0.015

+/-0.015 1.23

+/-0.142

+/-0.142 U

0.023

+/-0.133

+/-0.133 0.483

+/-0.186

+/-0.186 0.643

+/-0.0859

+/-0.0859 U

0.0362

+/-0.0274

+/-0.0274 U

0.00184

+/-0.0192

+/-0.0192 U

-0.00297

+/-0.0202

+/-0.0202 U

-0.0113

+/-0.0466

+/-0.0466 U

-0.0413

+/-0.0546

+/-0.0546 U

0.0412 pCi/g 24 pCi/g 11 pCi/g 10 pCi/g 20 pCi/g 91 pCi/g 120 pCi/g 113 pCi/g 105 pCi/g 62 pCi/g 39 pCi/g pCi/g pci/g o.Cj/g pCi/g pCi/g (0% - 100%) MJHI 09/20/06 17:33 (0% - 100%)

(0%- 100%)

(0% - 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0% - 100%)

(0%- 100%)

101

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

171454 Parmname Rad Gamma Spec Bateh 569468 0C Summary Page 7 of 12 Sample Qual QC Units RPD%

REC%

Range AnIst Date Time NOM Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Rad*um-226 Silver-108m Thallium-208 QC1201185430 Actinium-228 Aniericium-241 Uncert:

+/-0.0653 TPU:

+/-0.0653 0.866 Uncert:

+/-0.084 TPU:

+/-0.084 0.680 Uncert:

+/-0.118 TPU:

+/-0.118 U

0.0469 Uncert:

+/-0.043 TPU:

+/-0.043 U

-0.00108 Uncert:

+/-0.0287 TPU:

+/-0.0287 14.8 Uncert:

+/-1.27 TPU:

+/-1.27 0.783 Uncert:

+/-0.136 TPU:

+/-0.136 u

0.0177 Uncert:

+/-0.0238 TPU:

+/-0.0238 0.316 Uncert:

+/-0.0603 TPU:

+/-0.0603

+/-0.0564

+/-0.0564 0.927

+/-0.0596

+/-0.0596 0.767

+/-0.070

+/-0.070 U

0.00508

+/-0.0169

+/-0.0169 U

0.00263

+/-0.0164

+/-0.0164 17.8

+/-0.845

+/-0.845 0.643

+/-0.0859

+/-0.0859 U

-0.0126

+/-0.0156

+/-0.0156 0.296

+/-0.0351

+/-0.0351 U

0.341

+/-0.793

+/-0.793 26.2

+/-2.16

+/-2.16 U

0.204.

+/-1.33

+/-1.33 U

-0.188

+/-0.328'

+/-0.328 U

0.093

+/-0.206

+/-0.206 10.5

+/-1.14

+/-1.14 15.3

+/-0.820

+/-0.820 pCi/g

, 7 pCV-g 12 pCi/g 161 pCi/g 481 pCi/g 18 pCi/g 20 pCi/g 1210 pCi/g 7

(0% - 20%)

(0%- 20%)

(0%- 100%)

(0% - 100%)

(0% - 20%)

(0%- 100%)

(0% - 100%)

(0% - 100%)

"'LCS Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Uncert:

TPU:

23.4 Unceit:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.57 Uncert:

TPU:

14.4 Uncert:

TPU:

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 112 (75%-125%)

09/20/06 08:54 110 (75%-125%)

106 (75%-.125%)

Cobalt-60 102

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

171454 Page 8 of 12 Parinname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 569468 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54.

Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QCI201185428 Actinium-228 Americium-241 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

U 0.480

+/-0.690

+/-0.690 U

0.0278

+/-0.420

+/-0.420 U

-0.105

+/-0.324

+/-0.324 U

-0.136

+/-0.185

+/-0.185 U

0.145

+/-0.273.

+/-0.273 U

-0.00508

+/-0.182

+/-0. 182 U

-0.0802

+/-0.154

+/-0.154 U

0.856

+/-1.60

+/-1.60 U

-0.188

+/-0.328

+/-0.328 U

0.0696

+/-0.145

+/-0.145 U

0.00973

+/-0.173

+/-0.173 U

0.0896

+/-0.0637

+/-0.0637 U

-0.00606

+/-0.0192

+/-0.0192 U

0.132

+/-0.146

+/-0.146 U

0.029

+/-0.0379

+/-0.0379 U

-0.0057

+/-0.0209 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

MB 09/20/06 17:32 Bismuth-212 Bismuth-214 Cesium-134 103

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gelocom Workorder:

171454 Parmname Rad Gamma Spec Batch 569468 QCSummarx Sample Qual QC Page 9 of 12 Units RPD%

REC%

Range Anist Date Time NOM TPU:

Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Unccrt:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0209 U

0.0192

+/-0.0192

+/-0.0192 U

-0.00341

+/-0.0192

+/-0.0192 U

-0.019

+/-0.0438

+/-0.0438 U

0.0245

+/-0.0504

+/-0.0504 U

0.0117

+/-0.0339

+/-0.0339 U

0.048

+/-0.0241

+/-0.0241 U

0.0142

+/-0.0503

+/-0.0503 U

0.0084

+/-0.0194

+/-0.0194 U

0.00987

+/-0.0159

+/-0.0159 U

0.049

+/-0.201

+/-0.201 U

0.029

+/-0.0379

+/-0.0379 U

0.00375

+/-0.0148

+/-0.0148 U

0.00107

+/-0.0293

+/-0.0293 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Rad Gas Flow Batch 567998 QC1201181990 171450001 DUP Strontium-90 QC1201181992 LCS Strontium-90 U

0.00357 Uncert:

+/-0.0189 TPU:

+/-0.0189 U

0.00343

+/-0.016

+/-0.016 pCi/g 0

(0% - 100%) KSDI 09116106 16:22 1.74 1.60 pCi/g 92 (75%-125%)

09/16/06 16:22 104

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

171454 Parmnamne Rad Gas Flow Batch 567998 QC1201181989 MB Strontium-90 QC1201181991 171450001 MS Strontium-90 Rad Liquid Scintillation Batch 567933 QC1201181850 171450001 DUP hion-55 QC1201181852 LCS Iron-55 QC1201181849 MB Iron-55

  • QC1201181851 171450001 MS Iron-55 Batch 567934 QC1201181855 171450001 DUP Nickel-63 QC1201181857 LCS Nickel-63 QC1201181854 MB Nickcl-63 QC1201181856 171450001 MS Nickel-63 Batch 567935 QC1201181859 171454026 DUP Technetiurm-99 NOM Uncert:

TPU Uncert:

TPU 1.59 Uncert:

TPU Uncert:

TPU 625 Uncert:

TPU Uncert:

TPU 703 Uncert:

TPU Uncert:

TPU 512 Uncert:

TPU Uncert:

TPU 594 Uncert:

TPU U

QC Summary Sample Qual

+/-0.0923

+/-0.104 U -

0.00814

+/-0.0156

+/-0.0156 0.00357 1.31

+/-0.0189

+/-0.0727

+/-0.0189

+/-0.0821 Page 10of 12 Units RPD%

REC%

Range AnIst Date Time pCi/g pCi/g 83 (75%-125%)

U

-9.33

+/-42.3

+/-42.3 U

-9.33

+/-42.3

+/-42.3 U

-2.65

+/-6.01

+1-6.01 U

-2.65

+/-6.01

+/-6.01 u

0.167 U

-6.78

+/-58.7

+/-58.7

599,

+/-50.6

+1-63.3 U

9.17

+1-33.0

+/-33.0 635

+/-62.9

+/-75.0 U

-1.49

+/-6.32

+/-6.32 456

+/-16.3

+/-21.9 U

-0.881

+1-5.53

+/-5.53 544

+/-18.3

+/-26.2 U

-0.187 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 0

(0% - 100%) VIXP I 96 (75%-125%)

90 (75%-125%)

09/16/06 16:22 09/16/06 16:22 09/19/06 14:59 09/19/06 15:32 09/19/06 14:42 09/19/06 15:15 09/16/06 13:14 09/16/06 14:17 09/16/06 12:42 09/16/06 13:45 09/23/06 12:01 0

(0%'-. 100%) VIXPI 89 (75%-125%)

92 (75%-125%)

pCi/g 0

(0% - 100%) KXRI 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

171454 Page 11 of 12 REC %

Ranne Anlst Parmname NOM Sanmle Oual OC Units RPD)%

Date Time NO Sam Rad Liquid Scintillation Batch 567935 QC1201181861 LCS Technetium-99 QC1201181858 MB Technetium-99 QC1201181860 171454026 MS Technetium-99 Uncert:

+/-0.285 TPU:

+/-0.285 12.9 Uncert:

TPU:

Uncert:

TPU:

+/-0.284

+/-0.284 12.6

+/-0.514

+/-0.588 U

0.0238

+/-0.252

+/-0.252 12.8

+/-0.552

+/-0.623 pCilg pCilg-pCilg-98 (75%-125%)

09/23/06 12:34 09/23/06 11:45 09/23/06 12:18 13.0 U

Uncert:

TPU:

0.167

+/-0.285

+/-0.285 99 (75%-125%)

Batch 567937 QC1201181863 171454026 DUP Carbon-14 QC1201181865 LCS Carbon-14 QC1201181862 MB Carbon-14

)QC1201181864

'171454026 MS C,arbon-14 U

0.0855 Uncert:

+/-0.0887 TPU:

+/-0.0887 U

0.0747

+/-0.0883

+/-0.0883 6.81

+/-0.458

+/-0.470 pCi/g 0

(0% - 100%) 'XD2 6.66 Uncert:

TPU:

Uncert:

TPU:

7.13 U

Uncert:

TPU:

U 0.0127

+/-0.0794

+/-0.0794 pCi/g pCi/g pCi/g 102 (75%-125%)

09/14/06 19:29 09/14/06 20:34 09/14/06 18:42 09/14/06 20:17 0.0855

+/-0.0887

+/-0.0887 6.82

+/-0.448

+/-0.460 96 (75%-125%)

Batch 567994 QC1201181978 171454026 DUP Tritium QC1201181980 LCS Tritium U

2.19 Uncert:

+/-4.65 TPU:

+/-4k65 65.1 Uncert:

TPU:

U

-0.623

+/-4.58

+/-4.58 pCi/g 0

(0% - 100%) ATH2 09/17/06 07:37 QC1201181977 Tritium MB 61.4

+/-7.48

+/-7.56 U

0.459

+/-4.46

+/-4.46 pCi/g pCi/g pCi/g-94 (75%-125%)

91 (75%-125%)

09/17/06 08:40 09/17/06 07:05 09/17/06 08:08 Uncert:

TPU:

QC1201181979 171454026 MS Tritium 65.7 U

Uncert:

TPU:

2.19

+/-4.65

+/-4.65 60.0

+/-7.47

+/-7.54 106

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

171454 Page 12 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample restults are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

U1 Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data S'mmmary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL,.a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

107

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

PRELIMINARY DATA REVIEW FORM Survey Unit:

Survey Unit Name:

Classification :

Survey Media:

Type of Survey :

Type of Measurement:

[umber of Measurements :

9530-0004 Central Peninsula 3

Soil Final Status Survey Radionuclide Specific 15 BASIC STATISTICAL QUANTITIES Cs-137 Target Level (pCi/g) :

5.38E+00 Minimum Value:

2.06E-02 Maximum Value :

3.53E-01 Mean :

1.48E-01 Median :

1.36E-01 Standard Deviation :

1.07E-01 Sample Identification 9530-0004-001F 9530-0004-002F 9530-0004-003F 9530-0004-004F 9530-0004-005F 9530-0004-006F 9530-0004-007F 9530-0004-008F 9530-0004-009F 9530-0004-01OF 9530-0004-011IF 9530-0004-012F 9530-0004-013F 9530-0004-014F 9530-0004-015F Reported Results Cs-137 Concentration (pCi/g) 1.41E-01 2.76E-01 2.12E-01 2.97E-02 1.99E-01 7.96E-02 3.53E-01 1.44E-01 1.36E-01 6.45E-02 9.81E-02 3.80E-02 8.70E-02 3.36E-01 2.06E-02 Detect?

+

+

+

+

+

+

+

+

+

+

+

+

+

Fraction of Target Level 0.026 0.051 0.039 0.006 0.037 0.015 0.066 0.027 0.025 0.012 0.018 0.007 0.016 0.062 0.004 Submitted by/DateJ 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

FREQUENCY PLOT FOR CESIUM-137 Survey Unit:

Survey Unit Name:

Mean:

9530-0004 Central Peninsula 1.48E-01 pCi/g Frequency Plot For Cs-137 10 8

2.LL2 I.9-1.7E028E037E0 2.06E-02 1.09E-01 1.97E-01 2.85E-01 3.74E-01 Upper End Value (pCi/g)

Upper End Observation Observation Value Frequency Frequency 2.06E-02 1

7%

1.09E-01 6

40%

1.97E-01 3

20%

2.85E-01 3

20%

3.74E-01 2

13%

Total:

15 100%

(a-)

/ojolo6 Submitted by/Dat6 Review "

te I /

I of 1

QUANTILE PLOT FOR CESIUM-137 Survey Unit:

9520-0003 Survey Unit Name: Southwest Site Storage Area Mean:

1.48E-01 pCi/g Quantile Plot For Cs-137 4.00E-01 3.50E-01 Ai--N-S3.00E-01 S2.50E-01 C

2.00E-01 1.50E-01 00 1.00E 5.OOE-02 0.00E+00 0

20 40 60 80 100 Percentage Cs-137 Rank Percentage 2.06E-02 1

3%

2.97E-02 2

10%

3.80E-02 3

17%

6.45E-02 4

23%

7.96E-02 5

30%

8.70E-02 6

37%

9.81E-02 7

43%

1.36E-01 8

50%

1.41E-01 9

57%

1.44E-01 10 63%

1.99E-01 11 70%

2.12E-01 12 77%

2.76E-01 13 83%

3.36E-01 14 90%

+,,*

3.53E-01 15 97%

S bittedf-I r

Submitted

/

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Sign Test Calculation Sheet For A Single Radionuclide or Gross Activity Measurements Survey Area Number: 9530 Survey Unit Number: 0004 Survey Area Name: Central Peninsula WPIR#: 2006-0038 Classification: 3 Type I (cc error): 0.05 (N): 15 Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)

DCGL - Results Sign 1.41E-01 5.24E+00 I

2.76E-01 5.1OE+00 2.12E-01 5.17E+00 I

2.97E-02 5.35E+00 1

1.99E-01 5.18E+00 I

7.96E-02 5.30E+00 I

3.53E-01 5.03E+00 1

1.44E-01 5.24E+00 I

1.36E-01 5.24E+00 I

6.45E-02 5.32E+00 1

9.81E-02 5.28E+00 I

3.80E-02 5.34E+00 1

8.70E-02 5.29E+00 1

3.36E-01 5.04E+00 I

2.06E-02 5.36E+00 1

Number of positive differences (S+): 15 Critical Value: 11 Performed by:

'ýck w c,,-

Survey Unit Meets Acceptance Criterion Date:

/ V/A 6A6 Independent Date:

III 10(o Page 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Health Physics Procedure 24265-000-GPP-GGGR-R5]24-000-Rev.CY-000 Attachment A HelhPyisPoeue22500G!GG-5I2-0-e.YOOAtcmn Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0004 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0004-004 Sample

Description:

Comparison of split samples collected from sample measurement location #4 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0004-004F, the comparison sample was 9530-0004-004FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (YIN)

K-40 11.5 4.24E-1 27 0.75-1.33 11.2 6.70E-1 0.97 Y

Comments/Corrective Actions: Not enough Cs-137 to yield an acceptable Resolution Table is provided to show acceptance criteria used to assess split samples.

Resolution 4-7 8 -15 16 -50 51 -200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85-1.18

/

(

Page 1 of 1

Health Physics Procedure 24265-000-GPP-GGGR-R5]24-000-Rev.CY-000 Attachment A HelhPyisPoeue22500GPGG-5I2-0-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0004 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0004-009 Sample

Description:

Comparison of split samples collected from sample measurement location #9 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0004-009F, the comparison sample was 9530-0004-009FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (YIN)

Cs-137 1.36E-1 2.56E-2 5

0.5-2.0 1.1 IE-1 1.82E-2 0.82 Y

_ I II_

I Comments/Corrective Actions: N/A Table is provided to show acceptance criteria used to assess split samples.

Resolution 4-7 8-15 16 -50 51 -200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80-1.25 0.85 -1.18 Performed By:

I Page 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9530-0004 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)

DQA Surface Soil Report Assessment Summary Site:

Planner(s):

Survey Unit Name:

Report Number:

Survey Unit Samples:

Reference Area Samples:

Test Performed:

Judgmental Samples:

Assessment

Conclusion:

9530-0004 McCarthy fdbo/*-e,/*

Central Peninsula 2

15 0

Sign Test Result:

Not Performed 0

EMC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve U

U a.I-5' Lii 1

0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0

I __________

I I __________

I I

-I aI

  • 11

______ I 1

1 lull: ____

4li4 I

Ima 0

1 2

3 4

5 Soil Coacentradex (p Ci/g), iucludig backgrauxd Prospective Power N

1-beta Actual Power LBGR i

Estimated Power DCGL Retrospective Power 6

COMPASS vl.0.0 1112812006 Page I

DQA Surface Soil Report Survey Unit Data NOTE:

Type = "S" indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number 9530-0004-001 F 9530-0004-002F 9530-0004-003F 9530-0004-004F 9530-0004-005F 9530-0004-006F 9530-0004-007F 9530-0004-008F 9530-0004-009F 9530-0004-01 OF 9530-0004-011 F 9530-0004-012F 9530-0004-013F 9530-0004-014F 9530-0004-015F Type S

S S

S S

S S

S S

S S

S S

S S

Cs-137 (pCi/g) 0.14 0.28 0.21 0.03 0.2 0.08 0.35 0.14 0.14 0.06 0.1 0.04 0.09 0.34 0.02 Basic Statistical Quantities Summary Statistic Survey Unit

Background

DQO Results Sample Number Mean (pCi/g)

Median (pCi/g)

Std Dev (pCi/g)

High Value (pCi/g)

Low Value (pCi/g) 15 0.15 0.14 0.11 0.35 0.02 N/A N/A N/A N/A N/A N/A N= 15 0.14 N/A 0.0879 N/A N/A COMPASS vl.0.0.P 11128/2006 Page 2