MONTHYEARML0614201232005-10-31031 October 2005 Marine Ecology Studies Related to Operation of PNPS Semi-Annual Report No. 66, Report Period: January 2005-June 2005 Project stage: Request ML0613900752005-12-31031 December 2005 2005 Source Registration Emission Estimates-PNPS Project stage: Request ML0602300462006-01-12012 January 2006 G20060064/LTR-06-0041 - Sen T. Murray, Rep V. Demacedo, and Rep T. Obrien Ltr Relicensing of Pilgrim and Vermont Yankee Project stage: Request ML0610002612006-04-0707 April 2006 4/7/06 - Notice of Intent to Prepare an Environmental Impact Statement and Conduct Scoping Process for License Renewal for the Pilgrim Nuclear Power Station Project stage: Other ML0620104822006-04-30030 April 2006 Marine Ecology Studies Report 67, Appendix B, Geometric Mean Monthly Ichthyoplankton Densities Jan-Dec. 2005 Project stage: Request ML0620104902006-05-0404 May 2006 Photos Taken on 05/04/2006 of View Looking Toward Pilgrim Station from Junction of Pricilla and White Horse Beaches Project stage: Request ML0614201642006-05-17017 May 2006 Environmental Scoping Meeting Handouts Project stage: Request ML0617000462006-05-17017 May 2006 Enclosure 3: Afternoon Transcript, Public Scoping Meeting for Pilgrim, 05/17/2006 Project stage: Request ML0617000502006-05-17017 May 2006 Enclosure 4: Evening Transcript, Public Scoping Meeting for Pilgrim, 05/17/2006 Project stage: Request ML0614100012006-05-19019 May 2006 Project Manager Change for the License Renewal Environmental Review for Pilgrim Nuclear Power Station Project stage: Other ML0614400262006-05-22022 May 2006 Request for Additional Information (RAI) Regarding Severe Accident Mitigation Alternatives (SAMA) for Pilgrim Nuclear Power Station Project stage: RAI ML0619304182006-07-0505 July 2006 License Renewal Application Amendment 4: Response to Request for Additional Information Regarding Severe Accident Mitigation Alternatives Project stage: Response to RAI ML0617000552006-07-13013 July 2006 Summary of Public Scoping Meetings Conducted Related to the Review of the Pilgrim Nuclear Power Station, License Renewal Application Project stage: Meeting 05000293/LER-2006-002, Re Small Quantities of Unaccountable Licensed Material2006-07-19019 July 2006 Re Small Quantities of Unaccountable Licensed Material Project stage: Request ML0620702952006-07-25025 July 2006 Summary of Conferences Calls with Entergy Nuclear Operations, Inc., to Discuss the Severe Accident Mitigation Alternatives Requests for Additional Information for Pilgrim Nuclear Power Station Project stage: RAI ML0620703052006-07-25025 July 2006 05/01-05/2006 Meeting Summary of Environmental Site Audit Related to the Review of the License Renewal Application for Pilgrim Project stage: Meeting ML0623605142006-08-23023 August 2006 Summary of Follow Up Conference Call with Entergy Nuclear Operations, Inc., to Discuss the Severe Accident Mitigation Alternatives Requests for Additional Information for Pilgrim Nuclear Power Station Project stage: RAI ML0627105172006-09-26026 September 2006 Issuance of Environmental Scoping Summary Report Associated with the Staffs Review of the Application by Entergy Nuclear Operations, Inc., for Renewal of the Operating License for Pilgrim Nuclear Power Station Project stage: Approval ML0628900012006-10-24024 October 2006 Summary of Conference Call with Entergy Nuclear Operations, Inc, to Discuss the Severe Accident Mitigation Alternatives Requests for Additional Information for Pilgrim Nuclear Power Station Project stage: RAI ML0632800732006-11-28028 November 2006 Request for Additional Information Regarding Severe Accident Mitigation Alternatives for Pilgrim Nuclear Power Station Project stage: RAI ML0633901662006-12-0808 December 2006 Biological Assessment and Essential Fish Habitat Assessment for License Renewal of Pilgrim Nuclear Power Station Project stage: Other ML0634104932006-12-0808 December 2006 Notice of Availability of the Draft Plant-Specific Supplement 29 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants (GEIS) Regarding Pilgrim Project stage: Draft Other ML0703305542006-12-14014 December 2006 Federal Register Notice - Entergy Nuclear Operations, Inc. Pilgrim Nuclear Power Station; Notice of Availability of the Draft Supplement 29 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants and Public Meeti Project stage: Draft Other ML0632601732006-12-31031 December 2006 2006/12/31-NUREG-1437, Supp 29, Generic Environmental Impact Statement for License Renewal of Nuclear Plants, Supplement 29, Regarding Pilgrim Nuclear Power Station, Draft Report Project stage: Draft Other ML0703600712007-01-23023 January 2007 Letter from NOAA-National Marine Fisheries Service Dated January 23, 2007 Regarding Essential Fish Habitat Request for Consultation for the Pilgrim Nuclear Power Station Project stage: Request ML0706003092007-01-24024 January 2007 Attachments to Pilgrim Draft Environmental Impact Statement Afternoon Meeting Transcripts Project stage: Request ML0703305622007-01-24024 January 2007 Dseis Meeting Presentation, Preliminary Results of Environmental Review Pilgrim Nuclear Power Station Project stage: Request ML0705301892007-01-24024 January 2007 Draft Environmental Impact Statement Public Meeting, January 24, 2007, Afternoon Transcript-Corrected Project stage: Request ML0705301852007-01-24024 January 2007 Draft Environmental Impact Statement Public Meeting, January 24, 2007, Evening Transcript-Corrected Project stage: Request ML0705104632007-02-0808 February 2007 Letter Dated February 8, 2007 from Massachusetts Historical Commission, Brona Simon, Regarding Pilgrim Nuclear Power Station License Renewal Application, RC36661 Project stage: Other ML0705402052007-03-0101 March 2007 Summary of Meeting with Pilgrim on the Draft Supplemental Environmental Impact Statement Regarding Pilgrim License Renewal Review ML0710204792007-03-0202 March 2007 E-MAIL: (PA) Distribution of Final Document: Summary of Public Meetings Draft SEIS Pilgrim Project stage: Draft Approval ML0720404802007-07-26026 July 2007 Ltr to M. Balduzzi, Notice of Availability of the Final Plant-Specific Supplement 29 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Pilgrim Nuclear Power Station Project stage: Other ML0720500472007-07-26026 July 2007 Ltr to EPA, Final Supplement 29 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Pilgrim Nuclear Power Station Project stage: Other ML0719900272007-07-31031 July 2007 NUREG-1437, Supp 29, Vol 2, Generic Environmental Impact Statement for the License Renewal of Nuclear Plants: Regarding Pilgrim Nuclear Plant Station, Final Report - Appendices Project stage: Acceptance Review ML0613904262009-02-14014 February 2009 Town of Kingston Conservation Commission Memo, February 14, 2006 in Regards to PNPS Relicensing Project stage: Request ML0613902562012-04-13013 April 2012 Land Use Maps of Site and Forest Management Land Project stage: Request 2006-07-13
[Table View] |
Text
November 28, 2006 Mr. Michael Kansler President Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601-1839
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING SEVERE ACCIDENT MITIGATION ALTERNATIVES FOR PILGRIM NUCLEAR POWER STATION (TAC NO. MC9676)
Dear Mr. Kansler:
The U.S. Nuclear Regulatory Commission staff (the staff) has reviewed the Severe Accident Mitigation Alternatives analysis submitted by Entergy Nuclear Operations, Inc., in support of its application for license renewal for the Pilgrim Nuclear Power Station, and has identified areas where additional information is needed to complete its review. Enclosed is the staffs request for additional information.
We request that you provide your responses to these questions within 30 days of the date of this letter, in order to support the license renewal review schedule. If you have any questions, please contact me at 301-415-1878 or via e-mail at ARW1@nrc.gov.
Sincerely,
/RA/
Alicia Williamson, Project Manager Environmental Section B Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-293
Enclosure:
As stated cc w/encl: See next page
ML063280073 Document name: C:\\FileNet\\ML063280073.wpd OFFICE DLR:LA DLR:PM DLR:BC NAME SFigueroa AWilliamson RFranovich DATE 11/28/06 11/28/06 11/28/06
Request for Additional Information (RAIs)
Regarding the Analysis of Severe Accident Mitigation Alternatives for the Pilgrim Nuclear Power Station 1.
Provide the complete MACCS2 user input file used for the revised calculations described in Entergy's July 5, 2006 response to RAIs. This should include all files necessary to reproduce Entergy's calculations, i.e., the ATMOS, EARLY, CHRONC files, as well as any auxiliary input files containing meteorological data, dose conversion factors, food chain data, and site data. This should be provided in the form of a CD.
Also identify and discuss any changes made to the MACCS2 source code.
2.
Provide updated versions of Environmental Report Tables E.1-14 through E.1-16, based on the revised reactor core radionuclide inventories.
Pilgrim Nuclear Power Station cc:
Mr. Gary J. Taylor Chief Executive Officer Entergy Operations 1340 Echelon Parkway Jackson, MS 39213 Mr. John T. Herron Sr. VP and Chief Operating Officer Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Christopher Schwarz Vice President, Operations Support Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Michael A. Balduzzi Site Vice President Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508 Mr. Kevin H. Bronson General Manager, Plant Operations Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508 Mr. Stephen J. Bethay Director, Nuclear Safety Assurance Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508 Mr. Oscar Limpias Vice President, Engineering Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. John F. McCann Director, Licensing Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Ms. Charlene D. Faison Manager, Licensing Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Michael J. Colomb Director of Oversight Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Bryan S. Ford Manager, Licensing Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360-5508 Assistant General Counsel Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. James H. Sniezek 5486 Nithsdale Drive Salisbury, MD 21801-2490 Mr. Michael D. Lyster 5931 Barclay Lane Naples, FL 34110-7306 Mr. Garrett D. Edwards 814 Waverly Road Kennett Square, PA 19348
Pilgrim Nuclear Power Station cc:
Mr. James Ross Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Senior Resident Inspector U. S. Nuclear Regulatory Commission Pilgrim Nuclear Power Station P.O. Box 867 Plymouth, MA 02360 Chairman, Board of Selectmen 11 Lincoln Street Plymouth, MA 02360 Chairman Nuclear Matters Committee Town Hall 11 Lincoln Street Plymouth, MA 02360 Chairman, Duxbury Board of Selectmen Town Hall 878 Tremont Street Duxbury, MA 02332 Plymouth Public Library Attn: Ms. Dinah OBrien 132 South Street Plymouth, MA 02360 Duxbury Free Library Attn: Mr. David Murphy 77 Alden Street Duxbury, MA 02332 Kingston Public Library Attn: Librarian Susan Olin 6 Green Street Kingston, MA 02364 Mark Sylvia Town Manager Town of Plymouth 11 Lincoln Street Plymouth, MA 02360 Ms. Mary Lampert Duxbury Nuclear Advisory Committee 148 Washington Street Duxbury, MA 02332 Office of the Attorney General One Ashburton Place 20th Floor Boston, MA 02108 Diane Curran, Esq.
Harmon, Curran, Spielberg
& Eisenberg, L.L.P.
1726 M Street, NW, Suite 600 Washington, DC 20036 Matthew Brock, Esq.
Assistant Attorney General Office of the Massachusetts Attorney General Environmental Protection Division One Ashburton Place, Room 1813 Boston, MA 02108-1598 Ms. Shelia Hollis Suite 700 1667 K Street, NW Washington, DC 20006 Ms. Molly Barlett 52 Crooked Lane Duxbury, MA 02332 David R. Lewis, Esq.
Paul A. Gaukler, Esq.
Pillsbury Winthrop Shaw Pittman LLP 2300 N Street, NW Washington, DC 20037-1128