NAI Report Release Page 1 of 133 Calculation Number: NAI-1149-020 Revision Number: 0
Title:
Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis
==
Description:==
This calculation analyzes the radiological consequences of the Small Line Break Outside of Containment event presented in section 14.23 of the Palisades FSAR using the Alternative Source Term methodology described in USNRC Reg. Guide 1.1 83.
A&L t
f
~
f o
~
Author h t e ' '
Steve Thomasson 6 / 4 10 C Date Jim Harrell Q &,, C ?, s NAI ~anaaemen4
~ a f e Tom ~ e o G e
NAI-1149-020, RO Page 2 of 133 NAI Calculation Approval Calculation Number: NAI-1149-020 Revision Number: 0
Title:
Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation
Description:
This calculation analyzes the radiological consequences of the Small Line Break Outside of Containment event presented in section 14.23 of the Palisades FSAR using the Alternative Source Term methodology described in USNRC Reg. Guide 1.183.
A~G-L T
~
G / ~ \\ O <
Author Date Steve Thomasson
NAI-1149-020, RO Scope of Review:
Page 3 of 133 Review included:
e A review of calculation methods was completed for consistency with plant-specific and generic regulatory requirements and guidance.
e Computer codes (RADTRAD-NAI) were checked for appropriate qualification.
e Calculation and code inputs and assumptions were verified against IAM document(s) and/or checked for reasonableness and conservatism.
e Computations were checked for correctness.
e References were verified as appropriate.
o Outputs from spreadsheets and utility programs were checked.
e Reported Results were verified against computer outputs.
o Results and conclusions were reviewed for reasonableness.
e Cases run were checked against procurement documents.
Design Verification - See Attachment 1 C (4 (4 Date Jim Harrell
NAI-1149-020, RO Page 4 of 133 Check items in the following lists to verify that project documentation and engineering calculations are complete. Mark any items that are not applicable with N/A notation.
Project Documentation Checklist:
o Project QA Plan.
o Project Organization.
o Project Work Scope and Design Plan.
o Project Calculation and Document Index.
o Project QA Requirements.
o Project Engineer Training and Qualification Forms.
o Project QA Training Certification Forms.
o Project Correspondence.
Engineering Calculations Checklist:
d Identification by subject, originator, reviewer, date and Project so that the calculation is retrievable.
Table of contents.
Statement of the objective of the analysis.
Analysis inputs and their sources.
d Assumptions and how they were developed or determined.
d and calculations.
d Identification of computer calculations, including computer type, computer program name and version, code input and output.
$ y s i o n s.
eview summary.
d Responses to review comments.
d References.
d Each page of the calculation shall be numbered and the first page shall indicate the total number of pages. The calculation pages may be numbered by sections with the first page of the section indicating the total number of pages in the section.
The Calculation Approval Sheet shall be signed and dated by the originator.
Numerical Applications Inc. Page 5 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Table of Contents
1.0 INTRODUCTION
............................................................................................................................ 7 2.0
SUMMARY
OF RESULTS............................................................................................................. 7 3.0 DESIGN INPUT............................................................................................................................... 8 3.1 SOURCE TERM INPUT...................................................................................................................... 8 3.2 OTHER INPUT.................................................................................................................................. 8 4.0 ASSUMPTIONS............................................................................................................................... 8 5.0 ACCEPTANCE CRITERIA............................................................................................................ 8 6.0 COMPUTER CODES...................................................................................................................... 9 7.0 CALCULATION............................................................................................................................ 10 7.1 PCS NOBLE GAS DOSE.................................................................................................................. 10 7.1.1 PCS Compartment.................................................................................................................... 12 7.1.2 Environment Compartment....................................................................................................... 12 7.1.3 Control Room Compartment..................................................................................................... 12 7.1.4 Small Line Break - Pathway 1.................................................................................................. 12 7.1.5 Control Room Unfiltered Makeup............................................................................................ 13 7.1.6 Control Room Filtered Makeup................................................................................................ 14 7.1.7 Control Room Unfiltered Inleakage......................................................................................... 14 7.1.8 Control Room Exhaust.............................................................................................................. 14 7.1.9 Plant Power and Release Information...................................................................................... 14 7.1.10 Dose Location Information................................................................................................... 15 7.1.11 Source Term and Plant Power.............................................................................................. 17 7.1.12 Release Fraction Timing File............................................................................................... 18 7.2 IODINE SPIKE DOSE CONTRIBUTION.............................................................................................. 19
8.0 REFERENCES
............................................................................................................................... 23 9.0 SLB RADTRAD-NAI ANALYSIS FILES................................................................................... 24 Tables Table 2-1 Small Line Break Outside of Containment - Radiological Dose.................................... 7 Table 7-1 Noble Gas Release Fraction Timing File.................................................................... 18 Table 7-2 Concurrent Iodine Spike Activity Appearance Rate.................................................... 21 Table 7-3 Concurrent Iodine Spike Release Fraction Timing File............................................... 22 Figures Figure 1 Small Line Break RADTRAD-NAI Model....................................................................... 11
Numerical Applications Inc. Page 6 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Attachments Verification Comments for Calculation NAI-1149-020 Rev. 0............................... 25 Palisades Small Line Break Iodine Source Term.................................................. 27 Palisades PCS Activity Source Term.................................................................... 41 Palisades Small Line Break PCS Noble Gas Dose.............................................. 55 Palisades Small Line Break Iodine Spike Dose.................................................... 85 RADTRAD-NAI Dose Conversion Factor File..................................................... 117
Numerical Applications Inc. Page 7 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 1.0 Introduction The purpose of this calculation is to analyze the radiological consequences of the Small Line Break Outside of Containment event presented in section 14.23 of the Palisades FSAR (Reference 2). This analysis will use the Alternative Source Term (AST) methodology described in Regulatory Guide 1.183 (Reference 1). Since Reg. Guide 1.183 does not provide specific guidance for this event, the general guidance of the Reg. Guide will be supplemented with guidance from Standard Review Plan (SRP) section 15.6.2. In accordance with SRP 15.6.2, the source term for this calculation will assume an accident-generated or concurrent iodine spike. In accordance with the assumptions of the current analysis of record for this event, a reactor trip is not assumed.
The previous analysis of this event included a pre-accident iodine spike case and a Tech. Spec.
PCS activity case. A pre-accident iodine spike is not required by the SRP. In addition, the Tech.
Spec. PCS activity case will be bounded by the concurrent iodine spike case; therefore, only the concurrent iodine spike case need be analyzed. The total dose for this event will consist of the dose from the initial PCS non-iodine nuclides plus the dose from the concurrent iodine spike.
2.0 Summary of Results The results of the small line break outside of containment are provided below. The control room shine dose is a bounding value determined in the shielding analysis calculation performed for the Palisade LOCA/MHA event (filter and external cloud doses from Table 1 of Reference 17).
Table 2-1 Small Line Break Outside of Containment - Radiological Dose TEDE Dose (rem)
Dose Contribution EAB LPZ CR PCS Noble Gas Dose 2.3134E-02 2.8590E-03 3.3831E-03 Iodine Spike Dose 3.9105E-01 4.8319E-02 2.6277E-01 Control Room Shine Dose 0.268 Total 0.41 0.05 0.53 Acceptance Criteria 2.5 2.5 5
Control Room Unfiltered Inleakage = 100 cfm
Numerical Applications Inc. Page 8 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 3.0 Design Input 3.1 Source Term Input Table 6-5 of Reference 16 presents the source term for the Palisades PCS activity. The iodine activities in the source term were adjusted to achieve the Technical Specification limit of 1.0 Ci/gm dose equivalent I-131. The non-iodine species were adjusted to achieve the Technical Specification limit of 100/E-bar for non-iodine activities. The pal_pcs.nif (Attachment 3) file presents the final adjusted primary coolant source term. The PCS activity in this file was used to determine the iodine generation rate for the accident generated (concurrent) iodine spike. Per the SRP, a factor of 500 was applied to the iodine generation rate for the concurrent iodine spike.
Computation of this iodine spike source term is discussed in Section 7.2 of this calculation.
3.2 Other Input Reference 5 lists other input, approved by Palisades, used in the development of the Palisades Small Break Outside of Containment RADTRAD-NAI models.
4.0 Assumptions Basic assumptions are consistent with those specified in Reg Guide 1.183, SRP Section 15.6.2, and the current licensing basis for this event.
5.0 Acceptance Criteria Reg. Guide 1.183, does not provide any direct guidance for the acceptance criteria for this event.
However, the SRP states that the acceptance criteria is a small fraction of the 10CFR100 values which is further described as 10% of the limit. In applying the AST methodology to the small line break outside of containment, that same 10% interpretation will be applied to the 10CFR part 50.67 limits. The acceptable dose limits for the Control Room (CR) are specified in 10CFR50.67.
For a small line break outside of containment, these limits are interpreted as:
Area Dose Criteria EAB 2.5 rem TEDE (for the worst two hour period)
LPZ 2.5 rem TEDE (for 30 days)
Control Room 5 rem TEDE (for 30 days)
Numerical Applications Inc. Page 9 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 6.0 Computer Codes The following computer code was used for performing the analyses presented in this calculation:
Computer Code Version Reference Purpose RADTRAD-NAI 1.1a(QA) 3 Radiological Dose Calculations RADTRAD-NAI (Reference 3) is qualified and maintained under the Numerical Applications Inc.
QA program (Reference 4). This QA program meets the requirements of 10CFR50 Appendix B with code error reporting per 10CFR21. RADTRAD-NAI is accessed via a controlled access web-based interface that provides a front-end for developing and submitting input models. The input developed via the interface is submitted to the RADTRAD-NAI solver that runs on an AMD-ATHLON based personal computer running LINUX.
Numerical Applications Inc. Page 10 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 7.0 Calculation A single release path was evaluated to assess the dose associated with the direct release of 160 gpm of PCS coolant through the line rupture for a period of 60 minutes. The calculations will assume 100 cfm of unfiltered inleakage into the control room.
Separate calculations will be required to compute individual dose contributions from the initial PCS non-iodine activity (Section 7.1) and the concurrent iodine spike activity (Section 7.2). The only difference in the calculations is the definition of the source terms.
7.1 PCS Noble Gas Dose The basic model includes a PCS compartment representing the PCS mass that will receive the activity source associated with the primary coolant activity. A direct release path will be modeled to represent the mass flow rate from the line break. Due to the modeling approach used for the iodine spike, separate models will be required to assess the dose contributions from the iodine spike and the contribution from the initial non-iodine (noble gas) activity in the PCS at the beginning of the event.
The RADTRAD-NAI model developed for initial PCS non-iodine activity dose calculation consists of three compartments and 5 pathways (see Figure 1):
Compartment Description Compartment Number RADTRAD-NAI Compartment Type PCS 1
(3) Normal Environment 2
(2) Environment Control Room 3
(1) Control Room Pathway Description Compartment Connections Pathway Number RADTRAD-NAI Pathway Type Line Break 1 to 2 1
Filtered Control Room Unfiltered Makeup 2 to 3 2
Filtered Control Room Filtered Makeup 2 to 3 3
Filtered Control Room Unfiltered Inleakage 2 to 3 4
Filtered Control Room Exhaust 3 to 2 5
Filtered
Numerical Applications Inc. Page 11 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Figure 1 Small Line Break RADTRAD-NAI Model Compartment 1 PCS Compartment 2 Environment Compartment 3 Control Room Exhaust Flow Unfiltered Inleakage Filtered Makeup Normal Makeup Line Break
Numerical Applications Inc. Page 12 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 The subsections that follow describe the RADTRAD-NAI input for the PCS initial non-iodine activity model. The PCS initial activity RADTRAD-NAI model was set up on a mass flow basis rather than the typical volumetric flow basis; therefore, the PCS volume was specified as lbm.
The output for this model, pal_slb_pcs_db_ast.out, is presented in Attachment 4.
7.1.1 PCS Compartment For the non-iodine dose calculation, the source term is defined as a concentration; therefore, using either the maximum or the minimum PCS volume is acceptable. From Reference 11, the minimum volume is 9400 ft3. At system conditions of 2060 psia and 560oF (Reference 11), the PCS mass is:
(9400 ft3) / (2.171017E-2 ft3/lbm) = 432,976.8 lbm The following input was specified for the PCS Compartment:
Volume 432,976.8 lbm Source Fraction 1.0 100% of source term applied to PCS volume Recirculation Filters no Natural Deposition no 7.1.2 Environment Compartment The only required input for the environment compartment is volume. This value is a dummy value; however, an input is required for this field. An arbitrary value of 2.0E20 ft3 was specified.
7.1.3 Control Room Compartment The control room volume was set to 35,923 ft3. The control room HVAC system is assumed to be operating in normal mode at the beginning of the event. The operators are assumed to place the control room into emergency filtration mode at 20 minutes (Reference 5).
Filter Efficiency Time (hours)
Flow Rate (cfm)
Aerosol Elemental Organic 0.0 0.0 99 99 99 0.3333 1413.6 99 99 99 720.0 1413.6 99 99 99 7.1.4 Small Line Break - Pathway 1 This pathway, which models the total small line break discharge flow, connects the PCS (Compartment 1) with the Environment Compartment (Compartment 2). The break flow is 160.0 gpm total for 60 minutes. The specific volume of the break flow at 35 psia and 135oF (Reference
- 5) is 1.626797E-2 ft3/lbm. The break mass flow rate is:
Numerical Applications Inc. Page 13 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 160.0 gpm flow rate = (160.0 gpm)(0.13368 ft3/gal)(1 / 1.626797E-2 ft3/lbm) = 1314.78 lbm/min Per section 5.4 of Appendix A to Reg. Guide 1.183, the flashing fraction is determined by the following equation:
FF = ( hf1 - hf2) / hfg Where, hf1 is the enthalpy of the break flow, hf2 is the enthalpy of saturated steam at 14.7 psia and 212oF, and hfg is the heat of vaporization at 212oF.
Thus, the break conditions of 35 psia and 135oF will produce no flashing.
The guidance provided in Appendix A of Reg. Guide 1.183 for the handling of ESF system leakage will be applied to the break flow release. This guidance specifies:
10% of the total iodine in the leaked fluid is assumed to be released to the air The form of the airborne iodine is 97% elemental and 3% organic Particulates (all nuclides with the exception of iodine and noble gases) are assumed to remain in the liquid phase In addition, it will be assumed that all of the noble gas in the break flow is released.
Small Line Break Flow Filter Efficiency Time (hours)
Flow Rate (lb/min)
Aerosol Elemental Organic 0.0 1314.78 0
0 0
1.0 0.0 0
0 0
720.0 0.0 0
0 0
7.1.5 Control Room Unfiltered Makeup The control room normal ventilation rate of 660 cfm is applied for the first 20 minutes. At 20 minutes, the control room enters recirculation mode.
Unfiltered Makeup Flow Filter Efficiency Time (hours)
Flow Rate (cfm)
Aerosol Elemental Organic 0.0 660.0 0
0 0
0.3333 0.0 0
0 0
720.0 0.0 0
0 0
Numerical Applications Inc. Page 14 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 7.1.6 Control Room Filtered Makeup The control room filtered makeup flow of 1413.6 cfm starts at 20 minutes (time of control room isolation).
Filtered Makeup Flow Filter Efficiency Time (hours)
Flow Rate (cfm)
Aerosol Elemental Organic 0.0 0.0 99 99 99 0.3333 1413.6 99 99 99 720.0 1413.6 99 99 99 7.1.7 Control Room Unfiltered Inleakage The unfiltered inleakage was set to 100 cfm.
Unfiltered Inleakage Filter Efficiency Time (hours)
Flow Rate (cfm)
Aerosol Elemental Organic 0.0 0.0 0
0 0
0.3333 100.0 0
0 0
720.0 100.0 0
0 0
7.1.8 Control Room Exhaust The control room exhaust is equal to the sum of the control room intake and inleakage flows.
Exhaust Flow Filter Efficiency Time (hours)
Flow Rate (cfm)
Aerosol Elemental Organic 0.0 660.0 0
0 0
0.3333 1513.6 0
0 0
720.0 1513.6 0
0 0
7.1.9 Plant Power and Release Information The nuclide inventory file containing the source term is pal_pcs.nif. The nif file lists the source term in terms of Ci/gm and the reference power level in the nif file is 1.0. The total source term is defined by the combination of the nif file activities, the nif file reference power level, and the plant power input to the RADTRAD model. Therefore, the plant power input to RADTRAD was used to account for the PCS mass and it was used to convert Ci to Curies.
At PCS conditions of 2060 psia and 560oF, the specific volume is 2.171017E-2 ft3/lbm. The minimum PCS volume is 9400 ft3.
Numerical Applications Inc. Page 15 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Plant Power = (9400 ft3)(1 / 2.171017E-2 ft3/lbm)(1 Ci / 106 Ci)(453.592 gm/lbm)
Plant Power = 196.395 gm-Ci/Ci As discussed in Section 7.1.4, the iodine fractions are 97% elemental and 3% organic:
Start of first release time (hours) 0.0 Calculate decay Yes Calculate daughters Yes Iodine Fraction - aerosol 0.0 Iodine Fraction - elemental 0.97 Iodine Fraction - organic 0.03 7.1.10 Dose Location Information Three dose locations were specified; the Exclusion Boundary (EAB), the Low Population Zone (LPZ), and the Control Room (CR). The X/Qs for the EAB and LPZ are from Table 5 of Reference 12. The breathing rates are from Section 4.1.3 of Reg. Guide 1.183:
Exclusion Boundary Data:
EAB /Q X/Q Table 1 Time (hours)
X/Q (sec/m3) 0.0 5.39E-4 720.0 5.39E-4 EAB & LPZ Breathing Rate Time (hours)
Breathing Rate (m3/sec) 0.0 3.5E-4 8.0 1.8E-4 24.0 2.3E-4 720.0 2.3E-4
Numerical Applications Inc. Page 16 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Low Population Zone Data:
LPZ /Q X/Q Table 2 Time (hours)
X/Q (sec/m3) 0.0 6.66E-5 2.0 3.03E-5 8.0 2.04E-5 24.0 8.67E-6 96.0 2.54E-6 720.0 2.54E-6 Control Room Data:
The breathing rates and occupancy factor for the control room are from Section 4.2.6 of Reg.
Guide 1.183. The line break occurs in the auxiliary building; therefore, the release is via the plant stack. The X/Qs correspond to the plant stack and are listed in Table 4 of Reference 12.
Table 3 - Control Room X/Q (Plant Stack to Normal Intake)
Time (hours)
X/Q (sec/m3) 0.0 6.10E-3 2.0 4.32E-3 8.0 1.73E-3 24.0 1.27E-3 96.0 9.79E-4 720.0 9.79E-4 Table 4 - Control Room X/Q (Plant Stack to Emergency Intake)
Time (hours)
X/Q (sec/m3) 0.0 8.32E-4 2.0 7.69E-4 8.0 2.83E-4 24.0 2.15E-4 96.0 1.57E-4 720.0 1.57E-4
Numerical Applications Inc. Page 17 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Control Room Breathing Rate Time (hours)
Breathing Rate (m3/sec) 0.0 3.5E-4 720.0 3.5E-4 Control Room Occupancy Factor Time (hours)
Factor 0.0 1.0 24.0 0.6 96.0 0.4 720.0 0.4 Dose Location Pathway Combinations Control Room Intake Path Release Path X/Q Table 2
1 3
3 1
4 4
1 3
7.1.11 Source Term and Plant Power Section 3.4 of Reg. Guide 1.183 specifies the radionuclide groups that should be considered for AST analyses. Reference 10 provides a listing of the individual nuclides and dose conversion factors used for the analyses presented in this calculation. The data provided in Reference 10 are consistent with Section 3.4 of Reg. Guide 1.183. The dose conversion factors provided in Reference 10 were obtained from Table 2.1 of Federal Guidance Report 11 and Table III.1 of Federal Guidance Report 12.
The source term is given by the nuclide inventory file pal_pcs.nif.
Numerical Applications Inc. Page 18 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 7.1.12 Release Fraction Timing File Table 7-1 presents the release fraction timing file, pal_slb_ng.rft, used for the noble gas case.
The release fractions for all non-noble gas nuclides were set to zero. 100% of the noble gas was specified to be released over a short period of time during the gap activity release phase.
Table 7-1 Noble Gas Release Fraction Timing File Release Fraction and Timing Name:
PWR, NUREG 1.183, Palisades SLB Noble Gas Release Duration (h): Design Basis Accident 0.1000E-02 0.0000E+00 0.0000E+00 0.0000E+00 Noble Gases:
0.1000E+01 0.0000E+00 0.0000E+00 0.0000E+00 Iodine:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cesium:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Tellurium:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Strontium:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Barium:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Ruthenium:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cerium:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Lanthanum:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Non-Radioactive Aerosols (kg):
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 End of Release File
Numerical Applications Inc. Page 19 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 7.2 Iodine Spike Dose Contribution This model is similar to the one described in Section 7.1 except that the source term is modeled to represent the iodine spike release. The following changes were applied:
the nuclide inventory file was changed to represent the concurrent iodine spike release fraction timing file was changed to represent the concurrent iodine spike plant power input to the RADTRAD model was changed to account for the change in the nuclide inventory file the PCS volume was changed to be consistent with the PCS activity determination (459,445 lbm) the line break flow rate was reduced by a factor of 10 to account for the assumption of 10%
iodine release from the break flow A multiplier of 500 for the concurrent iodine spike is required by Section 15.6.2 of the SRP. The definition of concurrent iodine spike is per Appendix E of Reg. Guide 1.183:
the iodine release rate from the fuel rods to the primary coolant (expressed in curies per unit time) increases to a value 500 times greater than the release rate corresponding to the iodine concentration at the equilibrium value (typically 1.0 µCi/gm DE I-131) specified in technical specifications (i.e., concurrent iodine spike case). A concurrent iodine spike need not be considered if fuel damage is postulated. The assumed iodine spike duration should be 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
Shorter spike durations may be considered on a case-by-case basis if it can be shown that the activity released by the 8-hour spike exceeds that available for release from the fuel gap of all fuel pins.
With iodine activity at equilibrium, the iodine release rate will be equal to the rate at which iodine is lost due to decay, purification, and primary system leakage:
R = A where: R = appearance rate (Ci/min)
= removal (min-1)
A= activity (Ci)
The iodine removal,, is equal to removal by decay, purification, and PCS leakage:
= decay + purification + leakage The iodine removal due to leakage and purification can be determined by a simple ratio:
purification + leakage = [(purification mass flow + leakage mass flow)] / PCS mass Reference 8 specifies a letdown temperature of 120oF. Using the PCS pressure of 2060 psia, gives a specific volume of 1.610482E-2 ft3/lbm for the letdown flow. Using reactor conditions of 2060 psia and 560oF gives a specific volume of 2.171017E-2 ft3/lbm for the leakage flow.
Numerical Applications Inc. Page 20 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Purification Flow
= 44 gpm (Reference 8, 40 gpm + 10% uncertainty)
= (44 gpm)(0.13368 ft3/gal)(1 / 1.610482E-2 ft3/lbm)
= 365.227 lbm/min Leakage Flow
= 11 gpm (Reference 15, PCS identified + unidentified leakage)
= (11 gpm)(0.13368 ft3/gal)(1 / 2.171017E-2 ft3/lbm)
= 67.732 lbm/min PCS mass
= 459,445 lbm (mass specified in Reference 8) purification + leakage = [365.227 lbm/min + 67.732 lbm/min)] / 459,445 lbm = 0.000942 min-1 Using iodine decay constants from Reference 10, the total removal can be determined:
131 = 0.000942 + 5.986968E-5 = 0.001002 min-1 132 = 0.000942 + 0.005023 = 0.005965 min-1 133 = 0.000942 + 0.000555 = 0.001497 min-1 134 = 0.000942 + 0.013178 = 0.014120 min-1 135 = 0.000942 + 0.001748 = 0.002690 min-1 Using the 1.0 Ci/gm D.E. I-131 concentrations from Table 7-2, the appearance rates can be determined:
Iodine Activity (Ci) = (D.E. I-131 Concentration) x (PCS Mass) x 1.0e-6 1.0 Ci/gm Iodine Appearance = (Iodine Activity) x (Iodine Removal) 500 Ci/gm Iodine Appearance = 500 x 1.0 Ci/gm Iodine Appearance (Note that Table 7-2 was copied from a spreadsheet; therefore, not all of the significant figures from the spreadsheet were carried over into the table).
Numerical Applications Inc. Page 21 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Table 7-2 Concurrent Iodine Spike Activity Appearance Rate Nuclide 1.0 Ci/gm D.E I-131 Concentrations (Ci/gm)
PCS Mass (gm)
Iodine Activity (Ci)
Iodine Removal (min-1) 1.0 Ci/gm Iodine Appearance (Ci/min) x 500 500 Ci/gm Iodine Appearance (Ci/min)
I-131 8.305E-01 2.084E+08 1.731E+02 0.001002 0.1734 500 86.7114868 I-132 1.917E-01 2.084E+08 3.995E+01 0.005965 0.2383 500 119.152137 I-133 8.624E-01 2.084E+08 1.797E+02 0.001497 0.2690 500 134.524016 I-134 7.510E-02 2.084E+08 1.565E+01 0.01412 0.2210 500 110.495326 I-135 3.673E-01 2.084E+08 7.655E+01 0.00269 0.2059 500 102.953824 Nuclide 500 Ci/gm Iodine Appearance (Ci/min) 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Production (Ci)
I-131 86.7114868 4.162E+04 I-132 119.152137 5.719E+04 I-133 134.524016 6.457E+04 I-134 110.495326 5.304E+04 I-135 102.953824 4.942E+04 The concurrent iodine spike was incorporated into the RADTRAD-NAI run by using modified versions of the nuclide inventory and release fraction timing files. In the nuclide inventory file, pal_slb_iodine.nif (Attachment 2), the activities for I-131 through I-135 were set to 1.0 and the activities for the remaining isotopes were set to zero. In addition, each iodine isotope was given a different release group number that corresponded to the modified release groupings specified in the release fraction timing file, pal_slb_iodine.rft. In the release fraction timing file, each iodine isotope was listed as a separate release group. The total 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> production (in Curies) for each iodine isotope was then specified to be released over an 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> period.
Since the total iodine production is specified in the release fraction timing file and since the reference power was set to 1.0 in the nuclide inventory file, the plant power value in the RADTRAD-NAI model (pal_slb_iodine_db_ast.psf) was set to 1.0.
In order to consistent with the determination of the iodine spike activity, the PCS mass was set equal to 459,445 lbm. The output for this model is provided in Attachment 5.
Numerical Applications Inc. Page 22 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 The modified release fraction timing file is given in below:
Table 7-3 Concurrent Iodine Spike Release Fraction Timing File Release Fraction and Timing Name:
PWR, NUREG 1.183, Palisades SLB Concurrent Iodine Spike Duration (h): Design Basis Accident 0.0100E+00 0.7990E+01 0.0000E+00 0.0000E+00 Noble Gases:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Iodine:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 I-131:
0.0000E+00 0.4162E+05 0.0000E+00 0.0000E+00 I-132:
0.0000E+00 0.5719E+05 0.0000E+00 0.0000E+00 I-133:
0.0000E+00 0.6457E+05 0.0000E+00 0.0000E+00 I-134:
0.0000E+00 0.5304E+05 0.0000E+00 0.0000E+00 I-135:
0.0000E+00 0.4942E+05 0.0000E+00 0.0000E+00 Cerium:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Lanthanum:
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Non-Radioactive Aerosols (kg):
0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 End of Release File
Numerical Applications Inc. Page 23 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 8.0 References
- 1. USNRC, Regulatory Guide 1.183, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Plants, July 2000.
- 2. Palisades Nuclear Plant FSAR, Revision 24.
- 3. Numerical Applications Inc., NAI-9912-04, Revision 4, RADTRAD-NAI Version 1.1a(QA)
Documentation, October 2004.
- 4. Numerical Applications Inc., Dose Methodology Quality Assurance Procedures, Revision 1, June 4, 2001.
- 5. NAI-E03-211 Project Memo 2004-07, Remaining Event Inputs, July 8 2004.
- 6. NAI Calculation Number NAI-1149-008 Rev. 0, Palisades Best Estimate Main Steam Line Break AST Radiological Analysis.
- 7. Palisades Plant Technical Specifications through Amendment 213.
- 8. NAI Calculation Number NAI-1149-007 Rev. 0, Primary Coolant Activity for Palisades.
- 9. NAI Calculation Number NAI-1149-001 Rev. 1, Source Terms for Palisades Dose Calculations.
- 10. NAI Calculation Number NAI-1101-001 Rev. 1, Generation of.nif and.inp Files for RADTRAD-NAI.
- 11. NAI-E03-211 Project Memo 2004-03, MHA/LOCA Inputs, June 11 2004.
- 12. NAI Calculation Number NAI-1149-002 Rev. 0, Determination of Atmospheric Dispersion Factors for Palisades.
- 13. Reference deleted.
- 14. NAI Calculation Number NAI-1149-003 Rev. 1, Determination of Direct Shine Doses for a LOCA for Palisades.
- 16. NAI-1149-011 Rev. 0, Primary Coolant Source Term Determination for Palisades Dose Calculations.
- 17. NAI Calculation Number NAI-1149-024 Rev. 0, Determination of Direct Shine Doses for a Design Basis LOCA for Palisades.
Numerical Applications Inc. Page 24 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 9.0 SLB RADTRAD-NAI Analysis Files RADTRAD-NAI SLB Case Files File Name Attachment #
Case pal_slb_iodine.nif Iodine spike source Term pal_pcs.nif PCS activity source term pal_slb_pcs_db_ast.out RADTRAD-NAI SLB PCS noble gas dose output pal_slb_iodine_db_ast.out RADTRAD-NAI SLB Iodine spike dose output pal_slb_ng.rft Table 7-1 PCS noble gas release fraction timing file pal_slb_iodine.rft Table 7-3 Iodine spike release fraction timing file nai-1101-001rev0.dcf FP&L AST dose conversion factor file
Numerical Applications Inc. Attachment 1 Page 25 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Verification Comments for Calculation NAI-1149-020 Rev. 0 Fill in the Control Room shine dose TBD in Table 2-1. Suggest adding the environment and the CR filter shine dose.
Comment 1 Page 6, Attachments - Please update the fields/title for Attachment 1. The calculation number should be -020 versus -010.
Response
TOC updated.
Comment 2 Page 8, Section 3.1 - The first sentence should reference Table 2 of Reference 8 or Table 6-5 of NAI-1149-011. If the reference is changed to NAI-1149-011, then comment 3 below is no longer applicable.
Response
Reference changed to NAI-1149-011 (Reference 16).
Comment 3 Page 8, Section 3.1 - Please provide a reference where the 1.0 Ci/gm dose equivalent I-131 and 100/E-bar adjustments are made or add the tables.
Response
NAI-1149-011 (Reference 16) has been added, per Comment 2.
Comment 4 Page 8, Section 5.0 - Please add a discussion that the letdown line is the small break outside of containment in Section 1.0.
Response
For consistency, Letdown line rupture has been changed to small line break outside of containment.
Comment 5 Page 19, Section 7.2, 2nd paragraph - Please mention that the definition for the concurrent iodine spike is from Appendix E of RG 1.183 which applies to Main Steam Line Breaks and is more conservative than Appendix F for Steam generator Tube Ruptures.
Response
The iodine spike multiplier of 500 is required by the SRP. Reg. Guide 1.183 was used to define the iodine spike. Section 7.2 has been updated to note this.
Comment 6 Reference 13 does not appear to be used. It should be deleted
Response
Reference deleted.
Numerical Applications Inc. Attachment 1 Page 26 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Comment 7
- The PCS volume in the model for the concurrent spike should be changed to 459,455 to be consistent with the basis for the PCS activity and associated spike calculation.
Response
Correction made. The model, results, and output attachment have been updated.
Comment 8 Reference 14 (shine calc.) is now Rev. 1.
Response
Reference revised.
Numerical Applications Inc. Attachment 2 Page 27 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Palisades Small Line Break Iodine Source Term Nuclide Inventory Name:
Palisades SLB Concurrent Iodine Spike Power Level:
0.1000E+01 Nuclides:
107 Nuclide 001:
Co-58 7
0.6117120000E+07 0.5800E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 002:
Co-60 7
0.1663401096E+09 0.6000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 003:
Kr-85 1
0.3382974720E+09 0.8500E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 004:
Kr-85m 1
0.1612800000E+05 0.8500E+02 0.0000E+00 Kr-85 0.2110E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 005:
Kr-87 1
0.4578000000E+04 0.8700E+02 0.0000E+00 Rb-87 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 006:
Kr-88 1
0.1022400000E+05 0.8800E+02 0.0000E+00 Rb-88 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 007:
Rb-86 3
0.1612224000E+07 0.8600E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 008:
Sr-89
Numerical Applications Inc. Attachment 2 Page 28 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 5
0.4363200000E+07 0.8900E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 009:
Sr-90 5
0.9189573120E+09 0.9000E+02 0.0000E+00 Y-90 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 010:
Sr-91 5
0.3420000000E+05 0.9100E+02 0.0000E+00 Y-91m 0.5780E+00 Y-91 0.4220E+00 none 0.0000E+00 Nuclide 011:
Sr-92 5
0.9756000000E+04 0.9200E+02 0.0000E+00 Y-92 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 012:
Y-90 9
0.2304000000E+06 0.9000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 013:
Y-91 9
0.5055264000E+07 0.9100E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 014:
Y-92 9
0.1274400000E+05 0.9200E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 015:
Y-93 9
0.3636000000E+05 0.9300E+02 0.0000E+00 Zr-93 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 016:
Zr-95 9
Numerical Applications Inc. Attachment 2 Page 29 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.5527872000E+07 0.9500E+02 0.0000E+00 Nb-95m 0.7000E-02 Nb-95 0.9930E+00 none 0.0000E+00 Nuclide 017:
Zr-97 9
0.6084000000E+05 0.9700E+02 0.0000E+00 Nb-97m 0.9470E+00 Nb-97 0.5300E-01 none 0.0000E+00 Nuclide 018:
Nb-95 9
0.3036960000E+07 0.9500E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 019:
Mo-99 7
0.2376000000E+06 0.9900E+02 0.0000E+00 Tc-99m 0.8760E+00 Tc-99 0.1240E+00 none 0.0000E+00 Nuclide 020:
Tc-99m 7
0.2167200000E+05 0.9900E+02 0.0000E+00 Tc-99 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 021:
Ru-103 7
0.3393792000E+07 0.1030E+03 0.0000E+00 Rh-103m 0.9970E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 022:
Ru-105 7
0.1598400000E+05 0.1050E+03 0.0000E+00 Rh-105 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 023:
Ru-106 7
0.3181248000E+08 0.1060E+03 0.0000E+00 Rh-106 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 024:
Rh-105 7
0.1272960000E+06
Numerical Applications Inc. Attachment 2 Page 30 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.1050E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 025:
Sb-127 4
0.3326400000E+06 0.1270E+03 0.0000E+00 Te-127m 0.1760E+00 Te-127 0.8240E+00 none 0.0000E+00 Nuclide 026:
Sb-129 4
0.1555200000E+05 0.1290E+03 0.0000E+00 Te-129m 0.2250E+00 Te-129 0.7750E+00 none 0.0000E+00 Nuclide 027:
Te-127 4
0.3366000000E+05 0.1270E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 028:
Te-127m 4
0.9417600000E+07 0.1270E+03 0.0000E+00 Te-127 0.9760E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 029:
Te-129 4
0.4176000000E+04 0.1290E+03 0.0000E+00 I-129 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 030:
Te-129m 4
0.2903040000E+07 0.1290E+03 0.0000E+00 Te-129 0.6500E+00 I-129 0.3500E+00 none 0.0000E+00 Nuclide 031:
Te-131m 4
0.1080000000E+06 0.1310E+03 0.0000E+00 Te-131 0.2220E+00 I-131 0.7780E+00 none 0.0000E+00 Nuclide 032:
Te-132 4
0.2815200000E+06 0.1320E+03
Numerical Applications Inc. Attachment 2 Page 31 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.0000E+00 I-132 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 033:
I-131 3
0.6946560000E+06 0.1310E+03 0.1000E+01 Xe-131m 0.1110E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 034:
I-132 4
0.8280000000E+04 0.1320E+03 0.1000E+01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 035:
I-133 5
0.7488000000E+05 0.1330E+03 0.1000E+01 Xe-133m 0.2900E-01 Xe-133 0.9710E+00 none 0.0000E+00 Nuclide 036:
I-134 6
0.3156000000E+04 0.1340E+03 0.1000E+01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 037:
I-135 7
0.2379600000E+05 0.1350E+03 0.1000E+01 Xe-135m 0.1540E+00 Xe-135 0.8460E+00 none 0.0000E+00 Nuclide 038:
Xe-133 1
0.4531680000E+06 0.1330E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 039:
Xe-135 1
0.3272400000E+05 0.1350E+03 0.0000E+00 Cs-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 040:
Cs-134 3
0.6507177120E+08 0.1340E+03 0.0000E+00
Numerical Applications Inc. Attachment 2 Page 32 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 041:
Cs-136 3
0.1131840000E+07 0.1360E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 042:
Cs-137 3
0.9467280000E+09 0.1370E+03 0.0000E+00 Ba-137m 0.9460E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 043:
Ba-139 6
0.4962000000E+04 0.1390E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 044:
Ba-140 6
0.1100736000E+07 0.1400E+03 0.0000E+00 La-140 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 045:
La-140 9
0.1449792000E+06 0.1400E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 046:
La-141 9
0.1414800000E+05 0.1410E+03 0.0000E+00 Ce-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 047:
La-142 9
0.5550000000E+04 0.1420E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 048:
Ce-141 8
0.2808086400E+07 0.1410E+03 0.0000E+00 none 0.0000E+00
Numerical Applications Inc. Attachment 2 Page 33 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 none 0.0000E+00 none 0.0000E+00 Nuclide 049:
Ce-143 8
0.1188000000E+06 0.1430E+03 0.0000E+00 Pr-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 050:
Ce-144 8
0.2456352000E+08 0.1440E+03 0.0000E+00 Pr-144m 0.1780E-01 Pr-144 0.9822E+00 none 0.0000E+00 Nuclide 051:
Pr-143 9
0.1171584000E+07 0.1430E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 052:
Nd-147 9
0.9486720000E+06 0.1470E+03 0.0000E+00 Pm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 053:
Np-239 8
0.2034720000E+06 0.2390E+03 0.0000E+00 Pu-239 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 054:
Pu-238 8
0.2768863824E+10 0.2380E+03 0.0000E+00 U-234 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 055:
Pu-239 8
0.7594336440E+12 0.2390E+03 0.0000E+00 U-235 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 056:
Pu-240 8
0.2062920312E+12 0.2400E+03 0.0000E+00 U-236 0.1000E+01 none 0.0000E+00
Numerical Applications Inc. Attachment 2 Page 34 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 none 0.0000E+00 Nuclide 057:
Pu-241 8
0.4544294400E+09 0.2410E+03 0.0000E+00 U-237 0.2450E-04 Am-241 0.1000E+01 none 0.0000E+00 Nuclide 058:
Am-241 9
0.1363919472E+11 0.2410E+03 0.0000E+00 Np-237 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 059:
Cm-242 9
0.1406592000E+08 0.2420E+03 0.0000E+00 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 060:
Cm-244 9
0.5715081360E+09 0.2440E+03 0.0000E+00 Pu-240 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 061:
I-130 2
0.4449600000E+05 0.1300E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 062:
Kr-83m 1
0.6588000000E+04 0.8300E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 063:
Xe-138 1
0.8502000000E+03 0.1380E+03 0.0000E+00 Cs-138 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 064:
Xe-131m 1
0.1028160000E+07 0.1310E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00
Numerical Applications Inc. Attachment 2 Page 35 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Nuclide 065:
Xe-133m 1
0.1890432000E+06 0.1330E+03 0.0000E+00 Xe-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 066:
Xe-135m 1
0.9174000000E+03 0.1350E+03 0.0000E+00 Xe-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 067:
Cs-138 3
0.1932000000E+04 0.1380E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 068:
Cs-134m 3
0.1044000000E+05 0.1340E+03 0.0000E+00 Cs-134 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 069:
Rb-88 3
0.1068000000E+04 0.8800E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 070:
Rb-89 3
0.9120000000E+03 0.8900E+02 0.0000E+00 Sr-89 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 071:
Sb-124 4
0.5201280000E+07 0.1240E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 072:
Sb-125 4
0.8741455200E+08 0.1250E+03 0.0000E+00 Te-125m 0.2280E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 073:
Numerical Applications Inc. Attachment 2 Page 36 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Sb-126 4
0.1071360000E+07 0.1260E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 074:
Te-131 4
0.1500000000E+04 0.1310E+03 0.0000E+00 I-131 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 075:
Te-133 4
0.7470000000E+03 0.1330E+03 0.0000E+00 I-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 076:
Te-134 4
0.2508000000E+04 0.1340E+03 0.0000E+00 I-134 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 077:
Te-125m 4
0.5011200000E+07 0.1250E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 078:
Te-133m 4
0.3324000000E+04 0.1330E+03 0.0000E+00 I-133 0.8700E+00 Te-133 0.1300E+00 none 0.0000E+00 Nuclide 079:
Ba-141 6
0.1096200000E+04 0.1410E+03 0.0000E+00 La-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 080:
Ba-137m 6
0.1531200000E+03 0.1370E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 081:
Pd-109
Numerical Applications Inc. Attachment 2 Page 37 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 7
0.4833720000E+05 0.1090E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 082:
Rh-106 7
0.2990000000E+02 0.1060E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 083:
Rh-103m 7
0.3367200000E+04 0.1030E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 084:
Tc-101 7
0.8520000000E+03 0.1010E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 085:
Eu-154 9
0.2777068800E+09 0.1540E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 086:
Eu-155 9
0.1565256960E+09 0.1550E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 087:
Eu-156 9
0.1312416000E+07 0.1560E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 088:
La-143 9
0.8538000000E+03 0.1430E+03 0.0000E+00 Ce-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 089:
Nb-97 9
Numerical Applications Inc. Attachment 2 Page 38 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.4326000000E+04 0.9700E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 090:
Nb-95m 9
0.3117600000E+06 0.9500E+02 0.0000E+00 Nb-95 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 091:
Pm-147 9
0.8278820780E+08 0.1470E+03 0.0000E+00 Sm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 092:
Pm-148 9
0.4639680000E+06 0.1480E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 093:
Pm-149 9
0.1910880000E+06 0.1490E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 094:
Pm-151 9
0.1022400000E+06 0.1510E+03 0.0000E+00 Sm-151 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 095:
Pm-148m 9
0.3568320000E+07 0.1480E+03 0.0000E+00 Pm-148 0.4600E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 096:
Pr-144 9
0.1036800000E+04 0.1440E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 097:
Pr-144m 9
0.4320000000E+03
Numerical Applications Inc. Attachment 2 Page 39 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.1440E+03 0.0000E+00 Pr-144 0.99900E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 098:
Sm-153 9
0.1681200000E+06 0.1530E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 099:
Y-94 9
0.1146000000E+04 0.9400E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 100:
Y-95 9
0.6420000000E+03 0.9500E+02 0.0000E+00 Zr-95 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 101:
Y-91m 9
0.2982600000E+04 0.9100E+02 0.0000E+00 Y-91 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 102:
Br-82 2
0.1270800000E+06 0.8200E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 103:
Br-83 2
0.8604000000E+04 0.8300E+02 0.0000E+00 Kr-83m 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 104:
Br-84 2
0.1908000000E+04 0.8400E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 105:
Am-242 9
0.5767200000E+05 0.2420E+03
Numerical Applications Inc. Attachment 2 Page 40 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.0000E+00 Cm-242 0.8270E+00 Pu-242 0.1730E+00 none 0.0000E+00 Nuclide 106:
Np-238 8
0.1829088000E+06 0.2380E+03 0.0000E+00 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 107:
Pu-243 8
0.1784160000E+05 0.2430E+03 0.0000E+00 Am-243 0.1000E+01 none 0.0000E+00 none 0.0000E+00 End of Nuclear Inventory File
Numerical Applications Inc. Attachment 3 Page 41 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Palisades PCS Activity Source Term Nuclide Inventory Name:
Palisades PCS Source 1.0 uCi/gm DE131 and 100/E-bar Power Level:
0.1000E+01 Nuclides:
107 Nuclide 001:
Co-58 7
0.6117120000E+07 0.5800E+02 0.5138E-02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 002:
Co-60 7
0.1663401096E+09 0.6000E+02 0.5872E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 003:
Kr-85 1
0.3382974720E+09 0.8500E+02 0.3890E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 004:
Kr-85m 1
0.1612800000E+05 0.8500E+02 0.8808E+00 Kr-85 0.2110E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 005:
Kr-87 1
0.4578000000E+04 0.8700E+02 0.5505E+00 Rb-87 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 006:
Kr-88 1
0.1022400000E+05 0.8800E+02 0.1615E+01 Rb-88 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 007:
Rb-86 3
0.1612224000E+07 0.8600E+02 0.1101E-01 none 0.0000E+00 none 0.0000E+00
Numerical Applications Inc. Attachment 3 Page 42 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 none 0.0000E+00 Nuclide 008:
Sr-89 5
0.4363200000E+07 0.8900E+02 0.3964E-02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 009:
Sr-90 5
0.9189573120E+09 0.9000E+02 0.3597E-03 Y-90 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 010:
Sr-91 5
0.3420000000E+05 0.9100E+02 0.1101E-02 Y-91m 0.5780E+00 Y-91 0.4220E+00 none 0.0000E+00 Nuclide 011:
Sr-92 5
0.9756000000E+04 0.9200E+02 0.4331E-03 Y-92 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 012:
Y-90 9
0.2304000000E+06 0.9000E+02 0.4698E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 013:
Y-91 9
0.5055264000E+07 0.9100E+02 0.1321E-01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 014:
Y-92 9
0.1274400000E+05 0.9200E+02 0.5285E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 015:
Y-93 9
0.3636000000E+05 0.9300E+02 0.3230E-03 Zr-93 0.1000E+01 none 0.0000E+00 none 0.0000E+00
Numerical Applications Inc. Attachment 3 Page 43 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Nuclide 016:
Zr-95 9
0.5527872000E+07 0.9500E+02 0.8808E-03 Nb-95m 0.7000E-02 Nb-95 0.9930E+00 none 0.0000E+00 Nuclide 017:
Zr-97 9
0.6084000000E+05 0.9700E+02 0.3597E-03 Nb-97m 0.9470E+00 Nb-97 0.5300E-01 none 0.0000E+00 Nuclide 018:
Nb-95 9
0.3036960000E+07 0.9500E+02 0.8808E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 019:
Mo-99 7
0.2376000000E+06 0.9900E+02 0.3083E+01 Tc-99m 0.8760E+00 Tc-99 0.1240E+00 none 0.0000E+00 Nuclide 020:
Tc-99m 7
0.2167200000E+05 0.9900E+02 0.2349E+01 Tc-99 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 021:
Ru-103 7
0.3393792000E+07 0.1030E+03 0.8808E-03 Rh-103m 0.9970E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 022:
Ru-105 7
0.1598400000E+05 0.1050E+03 0.1028E-03 Rh-105 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 023:
Ru-106 7
0.3181248000E+08 0.1060E+03 0.3890E-03 Rh-106 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 024:
Numerical Applications Inc. Attachment 3 Page 44 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Rh-105 7
0.1272960000E+06 0.1050E+03 0.4037E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 025:
Sb-127 4
0.3326400000E+06 0.1270E+03 0.3156E-01 Te-127m 0.1760E+00 Te-127 0.8240E+00 none 0.0000E+00 Nuclide 026:
Sb-129 4
0.1555200000E+05 0.1290E+03 0.1762E-01 Te-129m 0.2250E+00 Te-129 0.7750E+00 none 0.0000E+00 Nuclide 027:
Te-127 4
0.3366000000E+05 0.1270E+03 0.3376E-01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 028:
Te-127m 4
0.9417600000E+07 0.1270E+03 0.5285E-02 Te-127 0.9760E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 029:
Te-129 4
0.4176000000E+04 0.1290E+03 0.2789E-01 I-129 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 030:
Te-129m 4
0.2903040000E+07 0.1290E+03 0.1615E-01 Te-129 0.6500E+00 I-129 0.3500E+00 none 0.0000E+00 Nuclide 031:
Te-131m 4
0.1080000000E+06 0.1310E+03 0.2716E-01 Te-131 0.2220E+00 I-131 0.7780E+00 none 0.0000E+00 Nuclide 032:
Te-132
Numerical Applications Inc. Attachment 3 Page 45 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 4
0.2815200000E+06 0.1320E+03 0.3523E+00 I-132 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 033:
I-131 2
0.6946560000E+06 0.1310E+03 0.8305E+00 Xe-131m 0.1110E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 034:
I-132 2
0.8280000000E+04 0.1320E+03 0.1917E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 035:
I-133 2
0.7488000000E+05 0.1330E+03 0.8624E+00 Xe-133m 0.2900E-01 Xe-133 0.9710E+00 none 0.0000E+00 Nuclide 036:
I-134 2
0.3156000000E+04 0.1340E+03 0.7510E-01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 037:
I-135 2
0.2379600000E+05 0.1350E+03 0.3673E+00 Xe-135m 0.1540E+00 Xe-135 0.8460E+00 none 0.0000E+00 Nuclide 038:
Xe-133 1
0.4531680000E+06 0.1330E+03 0.5138E+02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 039:
Xe-135 1
0.3272400000E+05 0.1350E+03 0.5432E+01 Cs-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 040:
Cs-134 3
Numerical Applications Inc. Attachment 3 Page 46 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.6507177120E+08 0.1340E+03 0.3597E+02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 041:
Cs-136 3
0.1131840000E+07 0.1360E+03 0.3156E+01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 042:
Cs-137 3
0.9467280000E+09 0.1370E+03 0.1908E+02 Ba-137m 0.9460E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 043:
Ba-139 6
0.4962000000E+04 0.1390E+03 0.3156E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 044:
Ba-140 6
0.1100736000E+07 0.1400E+03 0.5211E-02 La-140 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 045:
La-140 9
0.1449792000E+06 0.1400E+03 0.2496E-02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 046:
La-141 9
0.1414800000E+05 0.1410E+03 0.1762E-03 Ce-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 047:
La-142 9
0.5550000000E+04 0.1420E+03 0.4991E-04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 048:
Ce-141 8
0.2808086400E+07
Numerical Applications Inc. Attachment 3 Page 47 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.1410E+03 0.8074E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 049:
Ce-143 8
0.1188000000E+06 0.1430E+03 0.4624E-03 Pr-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 050:
Ce-144 8
0.2456352000E+08 0.1440E+03 0.6826E-03 Pr-144m 0.1780E-01 Pr-144 0.9822E+00 none 0.0000E+00 Nuclide 051:
Pr-143 9
0.1171584000E+07 0.1430E+03 0.7340E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 052:
Nd-147 9
0.9486720000E+06 0.1470E+03 0.3156E-03 Pm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 053:
Np-239 8
0.2034720000E+06 0.2390E+03 0.0000E+00 Pu-239 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 054:
Pu-238 8
0.2768863824E+10 0.2380E+03 0.0000E+00 U-234 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 055:
Pu-239 8
0.7594336440E+12 0.2390E+03 0.0000E+00 U-235 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 056:
Pu-240 8
0.2062920312E+12 0.2400E+03
Numerical Applications Inc. Attachment 3 Page 48 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.0000E+00 U-236 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 057:
Pu-241 8
0.4544294400E+09 0.2410E+03 0.0000E+00 U-237 0.2450E-04 Am-241 0.1000E+01 none 0.0000E+00 Nuclide 058:
Am-241 9
0.1363919472E+11 0.2410E+03 0.0000E+00 Np-237 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 059:
Cm-242 9
0.1406592000E+08 0.2420E+03 0.0000E+00 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 060:
Cm-244 9
0.5715081360E+09 0.2440E+03 0.0000E+00 Pu-240 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 061:
I-130 2
0.4449600000E+05 0.1300E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 062:
Kr-83m 1
0.6588000000E+04 0.8300E+02 0.2349E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 063:
Xe-138 1
0.8502000000E+03 0.1380E+03 0.0000E+00 Cs-138 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 064:
Xe-131m 1
0.1028160000E+07 0.1310E+03 0.3303E+00
Numerical Applications Inc. Attachment 3 Page 49 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 065:
Xe-133m 1
0.1890432000E+06 0.1330E+03 0.1248E+01 Xe-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 066:
Xe-135m 1
0.9174000000E+03 0.1350E+03 0.3523E+00 Xe-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 067:
Cs-138 3
0.1932000000E+04 0.1380E+03 0.5138E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 068:
Cs-134m 3
0.1044000000E+05 0.1340E+03 0.3376E-01 Cs-134 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 069:
Rb-88 3
0.1068000000E+04 0.8800E+02 0.1688E+01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 070:
Rb-89 3
0.9120000000E+03 0.8900E+02 0.4257E-01 Sr-89 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 071:
Sb-124 4
0.5201280000E+07 0.1240E+03 0.8074E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 072:
Sb-125 4
0.8741455200E+08 0.1250E+03 0.6753E-02 Te-125m 0.2280E+00
Numerical Applications Inc. Attachment 3 Page 50 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 none 0.0000E+00 none 0.0000E+00 Nuclide 073:
Sb-126 4
0.1071360000E+07 0.1260E+03 0.4551E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 074:
Te-131 4
0.1500000000E+04 0.1310E+03 0.1101E-01 I-131 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 075:
Te-133 4
0.7470000000E+03 0.1330E+03 0.0000E+00 I-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 076:
Te-134 4
0.2508000000E+04 0.1340E+03 0.1541E-01 I-134 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 077:
Te-125m 4
0.5011200000E+07 0.1250E+03 0.1468E-02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 078:
Te-133m 4
0.3324000000E+04 0.1330E+03 0.8808E-02 I-133 0.8700E+00 Te-133 0.1300E+00 none 0.0000E+00 Nuclide 079:
Ba-141 6
0.1096200000E+04 0.1410E+03 0.6679E-04 La-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 080:
Ba-137m 6
0.1531200000E+03 0.1370E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00
Numerical Applications Inc. Attachment 3 Page 51 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 none 0.0000E+00 Nuclide 081:
Pd-109 7
0.4833720000E+05 0.1090E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 082:
Rh-106 7
0.2990000000E+02 0.1060E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 083:
Rh-103m 7
0.3367200000E+04 0.1030E+03 0.8808E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 084:
Tc-101 7
0.8520000000E+03 0.1010E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 085:
Eu-154 9
0.2777068800E+09 0.1540E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 086:
Eu-155 9
0.1565256960E+09 0.1550E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 087:
Eu-156 9
0.1312416000E+07 0.1560E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 088:
La-143 9
0.8538000000E+03 0.1430E+03 0.0000E+00 Ce-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00
Numerical Applications Inc. Attachment 3 Page 52 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Nuclide 089:
Nb-97 9
0.4326000000E+04 0.9700E+02 0.5945E-04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 090:
Nb-95m 9
0.3117600000E+06 0.9500E+02 0.6239E-05 Nb-95 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 091:
Pm-147 9
0.8278820780E+08 0.1470E+03 0.8808E-04 Sm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 092:
Pm-148 9
0.4639680000E+06 0.1480E+03 0.1248E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 093:
Pm-149 9
0.1910880000E+06 0.1490E+03 0.2202E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 094:
Pm-151 9
0.1022400000E+06 0.1510E+03 0.6092E-04 Sm-151 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 095:
Pm-148m 9
0.3568320000E+07 0.1480E+03 0.1908E-04 Pm-148 0.4600E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 096:
Pr-144 9
0.1036800000E+04 0.1440E+03 0.6826E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 097:
Numerical Applications Inc. Attachment 3 Page 53 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Pr-144m 9
0.4320000000E+03 0.1440E+03 0.0000E+00 Pr-144 0.9990E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 098:
Sm-153 9
0.1681200000E+06 0.1530E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 099:
Y-94 9
0.1146000000E+04 0.9400E+02 0.1028E-04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 100:
Y-95 9
0.6420000000E+03 0.9500E+02 0.0000E+00 Zr-95 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 101:
Y-91m 9
0.2982600000E+04 0.9100E+02 0.6533E-03 Y-91 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 102:
Br-82 2
0.1270800000E+06 0.8200E+02 0.1835E-01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 103:
Br-83 2
0.8604000000E+04 0.8300E+02 0.4844E-01 Kr-83m 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 104:
Br-84 2
0.1908000000E+04 0.8400E+02 0.1982E-01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 105:
Am-242
Numerical Applications Inc. Attachment 3 Page 54 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 9
0.5767200000E+05 0.2420E+03 0.0000E+00 Cm-242 0.8270E+00 Pu-242 0.1730E+00 none 0.0000E+00 Nuclide 106:
Np-238 8
0.1829088000E+06 0.2380E+03 0.0000E+00 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 107:
Pu-243 8
0.1784160000E+05 0.2430E+03 0.0000E+00 Am-243 0.1000E+01 none 0.0000E+00 none 0.0000E+00 End of Nuclear Inventory File
Numerical Applications Inc. Attachment 4 Page 55 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Palisades Small Line Break PCS Noble Gas Dose RADTRAD-NAI Version 1.1a(QA) run on May 9, 2005 at 05:49:23 File information Plant file name = pal/SLB/db/pal_slb_pcs_db_ast.psf Inventory file name = pal/SLB/db/pal_pcs.nif Scenario file name = pal/SLB/db/pal_slb_pcs_db_ast.psf Release file name = pal/SLB/db/pal_slb_ng.rft Dose conversion file name = pal/SLB/db/nai-1101-001rev0.dcf
- RADTRAD-NAI 1.1a(QA)
- 09 May 2005 05:49:20
- Palisades Small Line Break Outside Cont.
- Nuclide inventory file pal/SLB/db/pal_pcs.nif
- Plant power 196.395
- Compartments 3
- Compartment 1:
PCS 3
432976.8 0
0 0
0
- Compartment 2:
Environment 2
2e+20 0
0 0
0
- Compartment 3:
Control Room 1
35923 0
1 0
0
- Pathways 5
- Pathway 1:
Small Line Break 1
2 2
Numerical Applications Inc. Attachment 4 Page 56 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0
- Pathway 2:
Control Room Unfiltered Makeup 2
3 2
- Pathway 3:
Control Room Filtered Makeup 2
3 2
- Pathway 4:
Control Room Unfiltered Inleakage 2
3 2
- Pathway 5:
Control Room Exhaust 3
2 2
- Sources 3
1 1 2 0 3 0
- dose conversion factors filename pal/SLB/db/nai-1101-001rev0.dcf
- release fraction and timing filename pal/SLB/db/pal_slb_ng.rft 0
1 1
- Iodine 0 0.97 0.03
- Overlying pool
- aerosol model 0
- elemental model 0
- organic model 0
- pH tracking 0
- Compartment detail
- Compartment 1:
1
- spray model 0
0 0
- filter model 0
- deposition model 0
0
- Compartment 2:
1
- spray model 0
0 0
- filter model 0
- deposition model 0
0
- Compartment 3:
1
- spray model 0
0 0
- filter model
Numerical Applications Inc. Attachment 4 Page 57 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 1
3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99
- deposition model 0
0
- Pathways:
- Pathway 1
- filter efficiency model 1
3 0 1314.78 0 0 0 1 0 0 0 0 720 0 0 0 0
- Pathway 2
- filter efficiency model 1
3 0 660 0 0 0 0.3333 0 0 0 0 720 0 0 0 0
- Pathway 3
- filter efficiency model 1
3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99
- Pathway 4
- filter efficiency model 1
3 0 0 0 0 0 0.3333 100 0 0 0 720 100 0 0 0
- Pathway 5
- filter efficiency model 1
3 0 660 0 0 0 0.3333 1513.6 0 0 0 720 1513.6 0 0 0
- x/q tables 4
EAB 2
0 0.000539 720 0.000539 LPZ 6
0 6.66e-05 2 3.03e-05 8 2.04e-05 24 8.67e-06 96 2.54e-06 720 2.54e-06 Control Room Unfiltered 6
0 0.0061 2 0.00432 8 0.00173 24 0.00127 96 0.000979 720 0.000979 Control Room Filtered 6
0 0.000832 2 0.000769 8 0.000283 24 0.000215 96 0.000157
Numerical Applications Inc. Attachment 4 Page 58 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 720 0.000157
- dose locations 3
- location name, compartment number and x/q table EAB 2
1
- br model 1
4 0 0.00035 8 0.00018 24 0.00023 720 0.00023
- of model 0
- location x/q input to be included 0
- location name, compartment number and x/q table LPZ 2
2
- br model 1
4 0 0.00035 8 0.00018 24 0.00023 720 0.00023
- of model 0
- location x/q input to be included 0
- location name, compartment number and x/q table Control Room 3
0
- br model 1
2 0 0.00035 720 0.00035
- of model 1
4 0 1 24 0.6 96 0.4 720 0.4
- location x/q input to be included 1
- number of intake combinations 3
- intake combinations 2 1 3 3 1 4 4 1 3
- time step count 1
0 0.02
- show plant, scenario, event, step, model 1
1 1
0 1
RADTRAD-NAI Version 1.1a(QA) run on May 9, 2005 at 05:49:23 Plant Description
Numerical Applications Inc. Attachment 4 Page 59 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Number of Nuclides = 107 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.9640E+02 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00)
Name: PCS Compartment volume = 4.3298E+05 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Small Line Break Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Unfiltered Makeup Pathway to compartment number 3: Control Room Filtered Makeup Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Small Line Break Pathway from compartment number 3: Control Room Exhaust Compartment number 3 Name: Control Room Compartment volume = 3.5923E+04 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust Pathway from compartment number 2: Control Room Unfiltered Makeup Pathway from compartment number 2: Control Room Filtered Makeup Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 5 RADTRAD-NAI Version 1.1a(QA) run on May 9, 2005 at 05:49:23 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Iodine fractions Aerosol = 0.0000E+00 Elemental = 9.7000E-01 Organic = 3.0000E-02 COMPARTMENT DATA Compartment number 1: PCS Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 PATHWAY DATA
Numerical Applications Inc. Attachment 4 Page 60 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Pathway number 1: Small Line Break Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 1.3148E+03 0.0000E+00 0.0000E+00 0.0000E+00 1.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: Control Room Unfiltered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: Control Room Filtered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 Pathway number 4: Control Room Unfiltered Inleakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 5: Control Room Exhaust Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.5136E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.5136E+03 0.0000E+00 0.0000E+00 0.0000E+00 X/Q DATA X/Q table 1: EAB Time (hr) X/Q (s
- m^-3) 0.0000E+00 5.3900E-04 7.2000E+02 5.3900E-04 X/Q table 2: LPZ Time (hr) X/Q (s
- m^-3) 0.0000E+00 6.6600E-05 2.0000E+00 3.0300E-05 8.0000E+00 2.0400E-05 2.4000E+01 8.6700E-06 9.6000E+01 2.5400E-06 7.2000E+02 2.5400E-06 X/Q table 3: Control Room Unfiltered Time (hr) X/Q (s
- m^-3) 0.0000E+00 6.1000E-03 2.0000E+00 4.3200E-03 8.0000E+00 1.7300E-03 2.4000E+01 1.2700E-03
Numerical Applications Inc. Attachment 4 Page 61 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 9.6000E+01 9.7900E-04 7.2000E+02 9.7900E-04 X/Q table 4: Control Room Filtered Time (hr) X/Q (s
- m^-3) 0.0000E+00 8.3200E-04 2.0000E+00 7.6900E-04 8.0000E+00 2.8300E-04 2.4000E+01 2.1500E-04 9.6000E+01 1.5700E-04 7.2000E+02 1.5700E-04 LOCATION DATA Location EAB is in compartment 2 Using X/Q Table 1 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location LPZ is in compartment 2 Using X/Q Table 2 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location Control Room is in compartment 3 Inleakage X/Q Table Assignments Inleakage Path Source Path X/Q Table 2 1 3 3 1 4 4 1 3 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 3.5000E-04 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 4.0000E-01 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 2.0000E-02 RADTRAD-NAI Version 1.1a(QA) run on May 9, 2005 at 05:49:23
Numerical Applications Inc. Attachment 4 Page 62 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Dose, Detailed Model and Detailed Inventory Output Detailed model information at time (H) = 0.0010 EAB Doses:
Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.2388E-05 1.7675E-11 2.7360E-05 1.2388E-05 Accumulated dose (rem) 1.2388E-05 1.7675E-11 2.7360E-05 1.2388E-05 LPZ Doses:
Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.5307E-06 2.1839E-12 3.3807E-06 1.5307E-06 Accumulated dose (rem) 1.5307E-06 2.1839E-12 3.3807E-06 1.5307E-06 Control Room Doses:
Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.7218E-09 1.1043E-13 1.2875E-07 1.7236E-09 Accumulated dose (rem) 1.7218E-09 1.1043E-13 1.2875E-07 1.7236E-09 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 0.0010 Ci kg Atoms Bq Kr-85 7.6391E+01 1.9471E-04 1.3795E+21 2.8265E+12 Kr-85m 1.7294E+02 2.1015E-08 1.4889E+17 6.3989E+12 Kr-87 1.0805E+02 3.8145E-09 2.6404E+16 3.9977E+12 Kr-88 3.1707E+02 2.5286E-08 1.7304E+17 1.1732E+13 Xe-133 1.0090E+04 5.3904E-05 2.4407E+20 3.7332E+14 Xe-135 1.0666E+03 4.1768E-07 1.8632E+18 3.9466E+13 Kr-83m 4.6112E+01 2.2350E-09 1.6216E+16 1.7062E+12 Xe-131m 6.4863E+01 7.7438E-07 3.5599E+18 2.3999E+12 Xe-133m 2.4508E+02 5.4618E-07 2.4731E+18 9.0678E+12 Xe-135m 6.9003E+01 7.5751E-10 3.3791E+15 2.5531E+12 Rb-88 5.5771E-01 4.6461E-12 3.1795E+13 2.0635E+10 PCS Transport Group Inventory:
Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 1.6318E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 4.6461E-12 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 0.0010 Ci kg Atoms Bq Kr-85 4.8021E-03 1.2240E-08 8.6718E+16 1.7768E+08 Kr-85m 1.0872E-02 1.3211E-12 9.3595E+12 4.0225E+08
Numerical Applications Inc. Attachment 4 Page 63 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Kr-87 6.7921E-03 2.3979E-13 1.6598E+12 2.5131E+08 Kr-88 1.9932E-02 1.5896E-12 1.0878E+13 7.3749E+08 Xe-133 6.3428E-01 3.3886E-09 1.5343E+16 2.3468E+10 Xe-135 6.7053E-02 2.6257E-11 1.1713E+14 2.4809E+09 Kr-83m 2.8987E-03 1.4050E-13 1.0194E+12 1.0725E+08 Xe-131m 4.0775E-03 4.8680E-11 2.2378E+14 1.5087E+08 Xe-133m 1.5406E-02 3.4335E-11 1.5546E+14 5.7003E+08 Xe-135m 4.3376E-03 4.7617E-14 2.1241E+11 1.6049E+08 Rb-88 3.9163E-05 3.2625E-16 2.2327E+09 1.4490E+06 Environment Transport Group Inventory:
Present Release Integral Time (h) = 0.0010 Release Rate/s Release Noble gases (atoms) 1.0258E+17 5.1290E+16 1.0258E+17 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.2625E-16 1.6313E-16 3.2625E-16 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 0.0010 Ci kg Atoms Bq Kr-85 1.3218E-05 3.3691E-11 2.3870E+14 4.8907E+05 Kr-85m 2.9925E-05 3.6363E-15 2.5763E+10 1.1072E+06 Kr-87 1.8696E-05 6.6003E-16 4.5687E+09 6.9174E+05 Kr-88 5.4864E-05 4.3754E-15 2.9942E+10 2.0300E+06 Xe-133 1.7459E-03 9.3272E-12 4.2233E+13 6.4597E+07 Xe-135 1.8457E-04 7.2273E-14 3.2240E+11 6.8289E+06
Numerical Applications Inc. Attachment 4 Page 64 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Kr-83m 7.9789E-06 3.8672E-16 2.8059E+09 2.9522E+05 Xe-131m 1.1224E-05 1.3399E-13 6.1598E+11 4.1527E+05 Xe-133m 4.2406E-05 9.4508E-14 4.2793E+11 1.5690E+06 Xe-135m 1.1939E-05 1.3107E-16 5.8467E+08 4.4175E+05 Rb-88 1.1407E-07 9.5028E-19 6.5031E+06 4.2206E+03 Control Room Transport Group Inventory:
Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 2.8236E+14 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 9.5028E-19 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 0.3333 EAB Doses:
Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 8.0900E-03 5.0809E-06 1.9124E-02 8.1738E-03 Accumulated dose (rem) 8.1024E-03 5.0809E-06 1.9151E-02 8.1862E-03 LPZ Doses:
Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.9961E-04 6.2780E-07 2.3630E-03 1.0100E-03 Accumulated dose (rem) 1.0011E-03 6.2781E-07 2.3663E-03 1.0115E-03 Control Room Doses:
Numerical Applications Inc. Attachment 4 Page 65 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.4732E-04 1.2326E-05 3.6499E-02 6.5065E-04 Accumulated dose (rem) 4.4732E-04 1.2326E-05 3.6499E-02 6.5066E-04 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 0.3333 Ci kg Atoms Bq Kr-85 7.1903E+01 1.8327E-04 1.2984E+21 2.6604E+12 Kr-85m 1.5462E+02 1.8789E-08 1.3312E+17 5.7211E+12 Kr-87 8.4851E+01 2.9955E-09 2.0735E+16 3.1395E+12 Kr-88 2.7520E+02 2.1947E-08 1.5019E+17 1.0182E+13 Xe-133 9.4801E+03 5.0647E-05 2.2932E+20 3.5076E+14 Xe-135 9.7993E+02 3.8373E-07 1.7117E+18 3.6257E+13 Kr-83m 3.8270E+01 1.8549E-09 1.3458E+16 1.4160E+12 Xe-131m 6.1003E+01 7.2830E-07 3.3480E+18 2.2571E+12 Xe-133m 2.2967E+02 5.1185E-07 2.3176E+18 8.4977E+12 Xe-135m 2.6305E+01 2.8877E-10 1.2882E+15 9.7328E+11 Rb-88 1.5777E+02 1.3144E-09 8.9946E+15 5.8376E+12 PCS Transport Group Inventory:
Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 1.5355E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.3144E-09 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 0.3333 Ci kg Atoms Bq Kr-85 4.4854E+00 1.1433E-05 8.0999E+19 1.6596E+11 Kr-85m 9.6458E+00 1.1721E-09 8.3041E+15 3.5689E+11 Kr-87 5.2931E+00 1.8687E-10 1.2935E+15 1.9585E+11 Kr-88 1.7167E+01 1.3691E-09 9.3691E+15 6.3519E+11 Xe-133 5.9139E+02 3.1594E-06 1.4306E+19 2.1881E+13 Xe-135 6.1130E+01 2.3938E-08 1.0678E+17 2.2618E+12 Kr-83m 2.3874E+00 1.1571E-10 8.3956E+14 8.8333E+10 Xe-131m 3.8055E+00 4.5433E-08 2.0886E+17 1.4080E+11 Xe-133m 1.4327E+01 3.1930E-08 1.4458E+17 5.3010E+11 Xe-135m 1.6409E+00 1.8014E-11 8.0358E+13 6.0715E+10 Rb-88 9.8422E+00 8.1992E-11 5.6110E+14 3.6416E+11 Environment Transport Group Inventory:
Present Release Integral Time (h) = 0.3333 Release Rate/s Release Noble gases (atoms) 3.7204E+18 5.1672E+16 9.5785E+19 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.1847E-12 4.4231E-14 8.1992E-11 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter
Numerical Applications Inc. Attachment 4 Page 66 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 0.3333 Ci kg Atoms Bq Kr-85 7.1357E-03 1.8188E-08 1.2886E+17 2.6402E+08 Kr-85m 1.5345E-02 1.8646E-12 1.3211E+13 5.6777E+08 Kr-87 8.4206E-03 2.9728E-13 2.0578E+12 3.1156E+08 Kr-88 2.7311E-02 2.1780E-12 1.4905E+13 1.0105E+09 Xe-133 9.4081E-01 5.0262E-09 2.2758E+16 3.4810E+10 Xe-135 9.7249E-02 3.8081E-11 1.6987E+14 3.5982E+09 Kr-83m 3.7980E-03 1.8408E-13 1.3356E+12 1.4052E+08 Xe-131m 6.0540E-03 7.2277E-11 3.3226E+14 2.2400E+08 Xe-133m 2.2792E-02 5.0796E-11 2.3000E+14 8.4332E+08 Xe-135m 2.6105E-03 2.8658E-14 1.2784E+11 9.6589E+07 Rb-88 1.5658E-02 1.3044E-13 8.9263E+11 5.7933E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 1.5238E+17 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.3044E-13 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Numerical Applications Inc. Attachment 4 Page 67 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 1.0000 EAB Doses:
Time (h) = 1.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.4568E-02 2.2847E-05 3.8031E-02 1.4945E-02 Accumulated dose (rem) 2.2670E-02 2.7928E-05 5.7182E-02 2.3131E-02 LPZ Doses:
Time (h) = 1.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.8001E-03 2.8230E-06 4.6992E-03 1.8466E-03 Accumulated dose (rem) 2.8012E-03 3.4508E-06 7.0655E-03 2.8581E-03 Control Room Doses:
Time (h) = 1.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.2310E-03 4.1040E-05 1.0332E-01 1.9081E-03 Accumulated dose (rem) 1.6784E-03 5.3366E-05 1.3982E-01 2.5587E-03 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 1.0000 Ci kg Atoms Bq Kr-85 6.3678E+01 1.6231E-04 1.1499E+21 2.3561E+12 Kr-85m 1.2352E+02 1.5009E-08 1.0634E+17 4.5701E+12 Kr-87 5.2249E+01 1.8446E-09 1.2768E+16 1.9332E+12 Kr-88 2.0712E+02 1.6518E-08 1.1304E+17 7.6634E+12 Xe-133 8.3657E+03 4.4693E-05 2.0237E+20 3.0953E+14 Xe-135 8.2536E+02 3.2320E-07 1.4417E+18 3.0538E+13 Kr-83m 2.6329E+01 1.2761E-09 9.2591E+15 9.7418E+11 Xe-131m 5.3938E+01 6.4395E-07 2.9603E+18 1.9957E+12 Xe-133m 2.0162E+02 4.4933E-07 2.0345E+18 7.4598E+12 Xe-135m 3.7995E+00 4.1710E-11 1.8606E+14 1.4058E+11 Rb-88 2.0748E+02 1.7284E-09 1.1828E+16 7.6766E+12 PCS Transport Group Inventory:
Overlying
Numerical Applications Inc. Attachment 4 Page 68 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 1.0000 Atmosphere Sump Pool Noble gases (atoms) 1.3590E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.7284E-09 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 1.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 1.0000 Ci kg Atoms Bq Kr-85 1.2712E+01 3.2402E-05 2.2956E+20 4.7036E+11 Kr-85m 2.4658E+01 2.9963E-09 2.1228E+16 9.1235E+11 Kr-87 1.0431E+01 3.6824E-10 2.5490E+15 3.8594E+11 Kr-88 4.1348E+01 3.2975E-09 2.2566E+16 1.5299E+12 Xe-133 1.6701E+03 8.9223E-06 4.0399E+19 6.1793E+13 Xe-135 1.6477E+02 6.4521E-08 2.8782E+17 6.0965E+12 Kr-83m 5.2562E+00 2.5476E-10 1.8484E+15 1.9448E+11 Xe-131m 1.0768E+01 1.2856E-07 5.9098E+17 3.9841E+11 Xe-133m 4.0249E+01 8.9701E-08 4.0616E+17 1.4892E+12 Xe-135m 7.5850E-01 8.3267E-12 3.7144E+13 2.8065E+10 Rb-88 4.1413E+01 3.4500E-10 2.3610E+15 1.5323E+12 Environment Transport Group Inventory:
Present Release Integral Time (h) = 1.0000 Release Rate/s Release Noble gases (atoms) 4.9618E+18 6.8914E+16 2.7130E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 6.3075E-12 8.7605E-14 3.4500E-10 Small Line Break Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 1.0000 Ci kg Atoms Bq Rb-88 6.6744E-03 5.5602E-14 3.8050E+11 2.4695E+08 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter
Numerical Applications Inc. Attachment 4 Page 69 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 5.5602E-14 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 1.0000 Ci kg Atoms Bq Kr-85 4.6191E-03 1.1773E-08 8.3412E+16 1.7091E+08 Kr-85m 8.9596E-03 1.0887E-12 7.7134E+12 3.3151E+08 Kr-87 3.7900E-03 1.3380E-13 9.2618E+11 1.4023E+08 Kr-88 1.5024E-02 1.1981E-12 8.1993E+12 5.5588E+08 Xe-133 6.0683E-01 3.2419E-09 1.4679E+16 2.2453E+10 Xe-135 5.9869E-02 2.3444E-11 1.0458E+14 2.2152E+09 Kr-83m 1.9099E-03 9.2567E-14 6.7163E+11 7.0665E+07 Xe-131m 3.9126E-03 4.6711E-11 2.1473E+14 1.4476E+08 Xe-133m 1.4625E-02 3.2593E-11 1.4758E+14 5.4111E+08 Xe-135m 2.7560E-04 3.0255E-15 1.3496E+10 1.0197E+07 Rb-88 7.3418E-03 6.1162E-14 4.1855E+11 2.7165E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 1.0000 Atmosphere Sump Pool Noble gases (atoms) 9.8576E+16 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 6.1162E-14 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 1.0000 Ci kg Atoms Bq Rb-88 6.9047E-03 5.7521E-14 3.9363E+11 2.5547E+08 Deposition Recirculating Time (h) = 1.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 5.7521E-14 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 1.0000 Ci kg Atoms Bq Rb-88 6.6744E-03 5.5602E-14 3.8050E+11 2.4695E+08
Numerical Applications Inc. Attachment 4 Page 70 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 5.5602E-14 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Time (h) = 1.0000 Ci kg Atoms Bq Rb-88 1.3579E-02 1.1312E-13 7.7414E+11 5.0243E+08 Detailed model information at time (H) = 2.0000 EAB Doses:
Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 6.4837E-06 6.3182E-09 1.6356E-05 6.5879E-06 Accumulated dose (rem) 2.2677E-02 2.7934E-05 5.7198E-02 2.3138E-02 LPZ Doses:
Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 8.0114E-07 7.8069E-10 2.0210E-06 8.1402E-07 Accumulated dose (rem) 2.8020E-03 3.4516E-06 7.0675E-03 2.8589E-03 Control Room Doses:
Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.9755E-04 1.6423E-05 4.2494E-02 7.6846E-04 Accumulated dose (rem) 2.1759E-03 6.9789E-05 1.8231E-01 3.3272E-03 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 2.0000 Ci kg Atoms Bq Kr-85 6.3678E+01 1.6231E-04 1.1499E+21 2.3561E+12 Kr-85m 1.0581E+02 1.2858E-08 9.1094E+16 3.9150E+12 Kr-87 3.0294E+01 1.0695E-09 7.4031E+15 1.1209E+12 Kr-88 1.6226E+02 1.2941E-08 8.8556E+16 6.0038E+12 Xe-133 8.3209E+03 4.4454E-05 2.0128E+20 3.0787E+14 Xe-135 7.6485E+02 2.9951E-07 1.3360E+18 2.8300E+13 Kr-83m 1.8028E+01 8.7377E-10 6.3397E+15 6.6702E+11 Xe-131m 5.3808E+01 6.4239E-07 2.9531E+18 1.9909E+12 Xe-133m 1.9897E+02 4.4344E-07 2.0078E+18 7.3620E+12 Xe-135m 2.5029E-01 2.7476E-12 1.2257E+13 9.2606E+09 Rb-88 1.8263E+02 1.5215E-09 1.0412E+16 6.7574E+12 PCS Transport Group Inventory:
Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 1.3577E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 71 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.5215E-09 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 2.0000 Ci kg Atoms Bq Kr-85 1.2717E+01 3.2413E-05 2.2964E+20 4.7051E+11 Kr-85m 2.1131E+01 2.5677E-09 1.8192E+16 7.8183E+11 Kr-87 6.0498E+00 2.1358E-10 1.4784E+15 2.2384E+11 Kr-88 3.2404E+01 2.5842E-09 1.7685E+16 1.1990E+12 Xe-133 1.6617E+03 8.8774E-06 4.0196E+19 6.1483E+13 Xe-135 1.5274E+02 5.9811E-08 2.6681E+17 5.6515E+12 Kr-83m 3.6001E+00 1.7449E-10 1.2660E+15 1.3321E+11 Xe-131m 1.0745E+01 1.2829E-07 5.8974E+17 3.9758E+11 Xe-133m 3.9735E+01 8.8555E-08 4.0097E+17 1.4702E+12 Xe-135m 4.9983E-02 5.4870E-13 2.4477E+12 1.8494E+09 Rb-88 3.6470E+01 3.0382E-10 2.0791E+15 1.3494E+12 Environment Transport Group Inventory:
Present Release Integral Time (h) = 2.0000 Release Rate/s Release Noble gases (atoms) 4.0764E+14 5.6617E+12 2.7113E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 2.2884E-16 3.1783E-18 3.0382E-10 Small Line Break Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq Rb-88 6.4521E-04 5.3751E-15 3.6783E+10 2.3873E+07 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 72 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Aerosols (kg) 5.3751E-15 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 2.0000 Ci kg Atoms Bq Kr-85 3.6866E-04 9.3965E-10 6.6573E+15 1.3640E+07 Kr-85m 6.1258E-04 7.4437E-14 5.2738E+11 2.2666E+07 Kr-87 1.7539E-04 6.1918E-15 4.2859E+10 6.4893E+06 Kr-88 9.3941E-04 7.4918E-14 5.1269E+11 3.4758E+07 Xe-133 4.8173E-02 2.5736E-10 1.1653E+15 1.7824E+09 Xe-135 4.4281E-03 1.7340E-12 7.7349E+12 1.6384E+08 Kr-83m 1.0437E-04 5.0586E-15 3.6703E+10 3.8617E+06 Xe-131m 3.1151E-04 3.7191E-12 1.7097E+13 1.1526E+07 Xe-133m 1.1519E-03 2.5672E-12 1.1624E+13 4.2621E+07 Xe-135m 1.4490E-06 1.5907E-17 7.0959E+07 5.3614E+04 Rb-88 5.1831E-04 4.3178E-15 2.9548E+10 1.9177E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 7.8602E+15 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 4.3178E-15 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 2.0000 Ci kg Atoms Bq Rb-88 2.0795E-03 1.7324E-14 1.1855E+11 7.6942E+07 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 1.7324E-14 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq Rb-88 6.4521E-04 5.3751E-15 3.6783E+10 2.3873E+07 Control Room Filtered Makeup Transport Group Inventory:
Pathway
Numerical Applications Inc. Attachment 4 Page 73 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 5.3751E-15 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Time (h) = 2.0000 Ci kg Atoms Bq Rb-88 2.7247E-03 2.2699E-14 1.5534E+11 1.0081E+08 Detailed model information at time (H) = 8.0000 EAB Doses:
Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.8142E-07 4.4312E-10 1.2464E-06 4.8873E-07 Accumulated dose (rem) 2.2677E-02 2.7934E-05 5.7200E-02 2.3138E-02 LPZ Doses:
Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.7063E-08 2.4910E-11 7.0069E-08 2.7474E-08 Accumulated dose (rem) 2.8020E-03 3.4516E-06 7.0676E-03 2.8590E-03 Control Room Doses:
Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.6944E-05 1.1518E-06 3.2382E-03 5.5944E-05 Accumulated dose (rem) 2.2129E-03 7.0940E-05 1.8555E-01 3.3831E-03 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 8.0000 Ci kg Atoms Bq Kr-85 6.3676E+01 1.6230E-04 1.1499E+21 2.3560E+12 Kr-85m 4.1818E+01 5.0815E-09 3.6002E+16 1.5473E+12 Kr-87 1.1509E+00 4.0631E-11 2.8125E+14 4.2583E+10 Kr-88 3.7518E+01 2.9921E-09 2.0476E+16 1.3882E+12 Xe-133 8.0567E+03 4.3042E-05 1.9489E+20 2.9810E+14 Xe-135 4.8404E+02 1.8954E-07 8.4552E+17 1.7910E+13 Kr-83m 1.8576E+00 9.0035E-11 6.5326E+14 6.8732E+10 Xe-131m 5.3030E+01 6.3311E-07 2.9104E+18 1.9621E+12 Xe-133m 1.8382E+02 4.0967E-07 1.8550E+18 6.8014E+12 Xe-135m 2.0453E-08 2.2453E-19 1.0016E+06 7.5674E+02 Rb-88 4.2882E+01 3.5724E-10 2.4447E+15 1.5866E+12 PCS Transport Group Inventory:
Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 1.3504E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.5724E-10 0.0000E+00 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 74 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 8.0000 Ci kg Atoms Bq Kr-85 1.2716E+01 3.2412E-05 2.2964E+20 4.7051E+11 Xe-133 1.6090E+03 8.5958E-06 3.8921E+19 5.9532E+13 Xe-131m 1.0590E+01 1.2644E-07 5.8123E+17 3.9184E+11 Xe-133m 3.6710E+01 8.1814E-08 3.7045E+17 1.3583E+12 Environment Transport Group Inventory:
Present Release Integral Time (h) = 8.0000 Release Rate/s Release Noble gases (atoms) 1.0480E+08 1.4556E+06 2.6969E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.3695E-23 1.9021E-25 7.1342E-11 Small Line Break Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 4.3867E-21 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter
Numerical Applications Inc. Attachment 4 Page 75 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 8.0000 Ci kg Atoms Bq Kr-85 9.5288E-11 2.4287E-16 1.7207E+09 3.5256E+00 Xe-133 1.2056E-08 6.4410E-17 2.9165E+08 4.4609E+02 Xe-135 7.2435E-10 2.8364E-19 1.2653E+06 2.6801E+01 Xe-131m 7.9356E-11 9.4741E-19 4.3553E+06 2.9362E+00 Xe-133m 2.7508E-10 6.1305E-19 2.7759E+06 1.0178E+01 Control Room Transport Group Inventory:
Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 2.0209E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 2.5841E-22 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 8.0000 Ci kg Atoms Bq Rb-88 3.7140E-09 3.0940E-20 2.1174E+05 1.3742E+02 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 3.0940E-20 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 4.3867E-21 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Numerical Applications Inc. Attachment 4 Page 76 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 8.0000 Ci kg Atoms Bq Rb-88 4.2406E-09 3.5327E-20 2.4175E+05 1.5690E+02 Detailed model information at time (H) = 24.0000 EAB Doses:
Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 6.8258E-14 1.3627E-17 1.9894E-13 6.8483E-14 Accumulated dose (rem) 2.2677E-02 2.7934E-05 5.7200E-02 2.3138E-02 LPZ Doses:
Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.5834E-15 5.1577E-19 7.5295E-15 2.5919E-15 Accumulated dose (rem) 2.8020E-03 3.4516E-06 7.0676E-03 2.8590E-03 Control Room Doses:
Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.2379E-12 6.8875E-14 5.1682E-10 6.3741E-12 Accumulated dose (rem) 2.2129E-03 7.0940E-05 1.8555E-01 3.3831E-03 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 24.0000 Ci kg Atoms Bq Kr-85 6.3669E+01 1.6228E-04 1.1497E+21 2.3557E+12 Kr-85m 3.5177E+00 4.2745E-10 3.0284E+15 1.3016E+11 Kr-87 1.8772E-04 6.6271E-15 4.5873E+10 6.9455E+06 Kr-88 7.5561E-01 6.0260E-11 4.1238E+14 2.7958E+10 Xe-133 7.3912E+03 3.9487E-05 1.7879E+20 2.7347E+14 Xe-135 1.4290E+02 5.5956E-08 2.4961E+17 5.2871E+12 Kr-83m 4.3351E-03 2.1012E-13 1.5245E+12 1.6040E+08 Xe-131m 5.1010E+01 6.0899E-07 2.7996E+18 1.8874E+12 Xe-133m 1.4882E+02 3.3168E-07 1.5018E+18 5.5065E+12 Rb-88 8.6364E-01 7.1947E-12 4.9236E+13 3.1955E+10 PCS Transport Group Inventory:
Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 1.3331E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 7.1947E-12 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Transport Group Inventory:
Present Release Integral Time (h) = 24.0000 Release Rate/s Release Noble gases (atoms) 2.8049E-10 3.8956E-12 2.6623E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 7.4829E-43 1.0393E-44 1.4368E-12 Small Line Break Transport Group Inventory:
Numerical Applications Inc. Attachment 4 Page 77 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.5516E-37 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Transport Group Inventory:
Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 5.4084E-09 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.4110E-41 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 1.8769E-36 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 78 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.5516E-37 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 96.0000 EAB Doses:
Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.0920E-31 9.5076E-37 3.5479E-31 1.0921E-31 Accumulated dose (rem) 2.2677E-02 2.7934E-05 5.7200E-02 2.3138E-02 LPZ Doses:
Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.7565E-33 1.5293E-38 5.7070E-33 1.7567E-33 Accumulated dose (rem) 2.8020E-03 3.4516E-06 7.0676E-03 2.8590E-03 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.0276E-30 2.2564E-33 5.5300E-28 5.0648E-30 Accumulated dose (rem) 2.2129E-03 7.0940E-05 1.8555E-01 3.3831E-03 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Kr-85 6.3635E+01 1.6220E-04 1.1491E+21 2.3545E+12 Kr-85m 5.1083E-05 6.2073E-15 4.3978E+10 1.8901E+06 Kr-88 1.7642E-08 1.4070E-18 9.6283E+06 6.5276E+02 Xe-133 5.0025E+03 2.6725E-05 1.2101E+20 1.8509E+14 Xe-135 5.8969E-01 2.3091E-10 1.0301E+15 2.1818E+10 Xe-131m 4.2832E+01 5.1136E-07 2.3507E+18 1.5848E+12 Xe-133m 5.7535E+01 1.2822E-07 5.8059E+17 2.1288E+12 Rb-88 2.0164E-08 1.6798E-19 1.1496E+06 7.4608E+02 PCS Transport Group Inventory:
Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 1.2731E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.6798E-19 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway
Numerical Applications Inc. Attachment 4 Page 79 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Transport Group Inventory:
Present Release Integral Time (h) = 96.0000 Release Rate/s Release Noble gases (atoms) 0.0000E+00 0.0000E+00 2.5424E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 3.3547E-20 Small Line Break Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Transport Group Inventory:
Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 80 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 720.0000 EAB Doses:
Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.6833-111 1.9746-123 1.9050-110 5.6833-111 Accumulated dose (rem) 2.2677E-02 2.7934E-05 5.7200E-02 2.3138E-02 LPZ Doses:
Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.6782-113 9.3049-126 8.9771-113 2.6782-113 Accumulated dose (rem) 2.8020E-03 3.4516E-06 7.0676E-03 2.8590E-03 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.7445-109 3.1240-120 1.9795-107 1.7445-109 Accumulated dose (rem) 2.2129E-03 7.0940E-05 1.8555E-01 3.3831E-03 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Kr-85 6.3343E+01 1.6145E-04 1.1439E+21 2.3437E+12 Xe-133 1.6236E+02 8.6740E-07 3.9275E+18 6.0074E+12 Xe-131m 9.4200E+00 1.1246E-07 5.1700E+17 3.4854E+11 Xe-133m 1.5233E-02 3.3949E-11 1.5372E+14 5.6363E+08 PCS Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 1.1483E+21 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 81 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Transport Group Inventory:
Present Release Integral Time (h) = 720.0000 Release Rate/s Release Noble gases (atoms) 0.0000E+00 0.0000E+00 2.2932E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 82 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Transport Group Totals in Model:
Noble Gases (atoms) 1.3776E+21 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 36004 I-131 Summary PCS Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.001 0.0000E+00 0.0000E+00 0.0000E+00 0.001 0.0000E+00 0.0000E+00 0.0000E+00 0.280 0.0000E+00 0.0000E+00 0.0000E+00 0.333 0.0000E+00 0.0000E+00 0.0000E+00
Numerical Applications Inc. Attachment 4 Page 83 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 0.600 0.0000E+00 0.0000E+00 0.0000E+00 0.860 0.0000E+00 0.0000E+00 0.0000E+00 1.000 0.0000E+00 0.0000E+00 0.0000E+00 1.260 0.0000E+00 0.0000E+00 0.0000E+00 1.520 0.0000E+00 0.0000E+00 0.0000E+00 1.780 0.0000E+00 0.0000E+00 0.0000E+00 2.000 0.0000E+00 0.0000E+00 0.0000E+00 2.260 0.0000E+00 0.0000E+00 0.0000E+00 2.520 0.0000E+00 0.0000E+00 0.0000E+00 2.780 0.0000E+00 0.0000E+00 0.0000E+00 3.040 0.0000E+00 0.0000E+00 0.0000E+00 3.300 0.0000E+00 0.0000E+00 0.0000E+00 3.560 0.0000E+00 0.0000E+00 0.0000E+00 3.820 0.0000E+00 0.0000E+00 0.0000E+00 4.080 0.0000E+00 0.0000E+00 0.0000E+00 4.340 0.0000E+00 0.0000E+00 0.0000E+00 4.600 0.0000E+00 0.0000E+00 0.0000E+00 4.860 0.0000E+00 0.0000E+00 0.0000E+00 5.120 0.0000E+00 0.0000E+00 0.0000E+00 5.380 0.0000E+00 0.0000E+00 0.0000E+00 5.640 0.0000E+00 0.0000E+00 0.0000E+00 5.900 0.0000E+00 0.0000E+00 0.0000E+00 6.160 0.0000E+00 0.0000E+00 0.0000E+00 6.420 0.0000E+00 0.0000E+00 0.0000E+00 6.680 0.0000E+00 0.0000E+00 0.0000E+00 6.940 0.0000E+00 0.0000E+00 0.0000E+00 7.200 0.0000E+00 0.0000E+00 0.0000E+00 7.460 0.0000E+00 0.0000E+00 0.0000E+00 7.720 0.0000E+00 0.0000E+00 0.0000E+00 7.980 0.0000E+00 0.0000E+00 0.0000E+00 8.000 0.0000E+00 0.0000E+00 0.0000E+00 8.260 0.0000E+00 0.0000E+00 0.0000E+00 8.520 0.0000E+00 0.0000E+00 0.0000E+00 8.780 0.0000E+00 0.0000E+00 0.0000E+00 9.040 0.0000E+00 0.0000E+00 0.0000E+00 9.300 0.0000E+00 0.0000E+00 0.0000E+00 9.560 0.0000E+00 0.0000E+00 0.0000E+00 9.820 0.0000E+00 0.0000E+00 0.0000E+00 10.080 0.0000E+00 0.0000E+00 0.0000E+00 24.000 0.0000E+00 0.0000E+00 0.0000E+00 96.000 0.0000E+00 0.0000E+00 0.0000E+00 720.000 0.0000E+00 0.0000E+00 0.0000E+00 Cumulative Dose Summary EAB LPZ Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.001 0.0000E+00 3.8234E-06 0.0000E+00 4.7243E-07 0.0000E+00 3.9206E-10 0.001 1.7675E-11 1.2388E-05 2.1839E-12 1.5307E-06 1.1043E-13 1.7236E-09 0.280 3.7128E-06 6.8925E-03 4.5877E-07 8.5166E-04 7.7621E-06 4.5030E-04 0.333 5.0809E-06 8.1862E-03 6.2781E-07 1.0115E-03 1.2326E-05 6.5066E-04 0.600 1.3501E-05 1.4473E-02 1.6682E-06 1.7883E-03 3.2534E-05 1.5622E-03 0.860 2.2840E-05 2.0213E-02 2.8222E-06 2.4976E-03 4.6790E-05 2.2419E-03 1.000 2.7928E-05 2.3131E-02 3.4508E-06 2.8581E-03 5.3366E-05 2.5587E-03 1.260 2.7931E-05 2.3135E-02 3.4512E-06 2.8586E-03 6.2108E-05 2.9707E-03 1.520 2.7933E-05 2.3136E-02 3.4514E-06 2.8588E-03 6.6601E-05 3.1784E-03 1.780 2.7934E-05 2.3137E-02 3.4515E-06 2.8589E-03 6.8823E-05 3.2817E-03 2.000 2.7934E-05 2.3138E-02 3.4516E-06 2.8589E-03 6.9789E-05 3.3272E-03 2.260 2.7934E-05 2.3138E-02 3.4516E-06 2.8589E-03 7.0380E-05 3.3554E-03 2.520 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0668E-05 3.3694E-03 2.780 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0808E-05 3.3763E-03 3.040 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0876E-05 3.3797E-03 3.300 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0909E-05 3.3814E-03 3.560 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0925E-05 3.3823E-03 3.820 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0933E-05 3.3827E-03 4.080 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0937E-05 3.3829E-03 4.340 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0939E-05 3.3830E-03 4.600 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 4.860 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 5.120 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03
Numerical Applications Inc. Attachment 4 Page 84 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 5.380 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 5.640 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 5.900 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 6.160 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 6.420 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 6.680 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 6.940 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 7.200 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 7.460 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 7.720 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 7.980 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 8.000 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 8.260 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 8.520 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 8.780 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 9.040 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 9.300 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 9.560 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 9.820 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 10.080 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 24.000 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 96.000 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 720.000 2.7934E-05 2.3138E-02 3.4516E-06 2.8590E-03 7.0940E-05 3.3831E-03 Worst Two-Hour Dose (Provided for Dose Location 1)
EAB Time Whole Body Thyroid Skin TEDE (hr) (rem) (rem) (rem) (rem) 0.0 2.2673E-02 2.7934E-05 5.7190E-02 2.3134E-02 30 Day Control Room Skin Dose Control Room Time Skin (hr) (rem) 720.0 1.8555E-01
Numerical Applications Inc. Attachment 5 Page 85 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Palisades Small Line Break Iodine Spike Dose RADTRAD-NAI Version 1.1a(QA) run on Jun 9, 2005 at 07:02:13 File information Plant file name = pal/SLB/db/pal_slb_iodine_db_ast.psf Inventory file name = pal/SLB/db/pal_slb_iodine.nif Scenario file name = pal/SLB/db/pal_slb_iodine_db_ast.psf Release file name = pal/SLB/db/pal_slb_iodine.rft Dose conversion file name = pal/SLB/db/nai-1101-001rev0.dcf
- RADTRAD-NAI 1.1a(QA)
- 09 Jun 2005 07:02:08
- Palisades Small Line Break Outside Cont.
- Nuclide inventory file pal/SLB/db/pal_slb_iodine.nif
- Plant power 1
- Compartments 3
- Compartment 1:
PCS 3
459455 0
0 0
0
- Compartment 2:
Environment 2
2e+20 0
0 0
0
- Compartment 3:
Control Room 1
35923 0
1 0
0
- Pathways 5
- Pathway 1:
Small Line Break 1
2 2
Numerical Applications Inc. Attachment 5 Page 86 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0
- Pathway 2:
Control Room Unfiltered Makeup 2
3 2
- Pathway 3:
Control Room Filtered Makeup 2
3 2
- Pathway 4:
Control Room Unfiltered Inleakage 2
3 2
- Pathway 5:
Control Room Exhaust 3
2 2
- Sources 3
1 1 2 0 3 0
- dose conversion factors filename pal/SLB/db/nai-1101-001rev0.dcf
- release fraction and timing filename pal/SLB/db/pal_slb_iodine.rft 0
1 1
- Iodine 0 0.97 0.03
- Overlying pool
- aerosol model 0
- elemental model 0
- organic model 0
- pH tracking 0
- Compartment detail
- Compartment 1:
1
- spray model 0
0 0
- filter model 0
- deposition model 0
0
- Compartment 2:
1
- spray model 0
0 0
- filter model 0
- deposition model 0
0
- Compartment 3:
1
- spray model 0
0 0
- filter model
Numerical Applications Inc. Attachment 5 Page 87 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 1
3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99
- deposition model 0
0
- Pathways:
- Pathway 1
- filter efficiency model 1
3 0 131.478 0 0 0 1 0 0 0 0 720 0 0 0 0
- Pathway 2
- filter efficiency model 1
3 0 660 0 0 0 0.3333 0 0 0 0 720 0 0 0 0
- Pathway 3
- filter efficiency model 1
3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99
- Pathway 4
- filter efficiency model 1
3 0 0 0 0 0 0.3333 100 0 0 0 720 100 0 0 0
- Pathway 5
- filter efficiency model 1
3 0 660 0 0 0 0.3333 1513.6 0 0 0 720 1513.6 0 0 0
- x/q tables 4
EAB 2
0 0.000539 720 0.000539 LPZ 6
0 6.66e-05 2 3.03e-05 8 2.04e-05 24 8.67e-06 96 2.54e-06 720 2.54e-06 Control Room Unfiltered 6
0 0.0061 2 0.00432 8 0.00173 24 0.00127 96 0.000979 720 0.000979 Control Room Filtered 6
0 0.000832 2 0.000769 8 0.000283 24 0.000215 96 0.000157
Numerical Applications Inc. Attachment 5 Page 88 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 720 0.000157
- dose locations 3
- location name, compartment number and x/q table EAB 2
1
- br model 1
4 0 0.00035 8 0.00018 24 0.00023 720 0.00023
- of model 0
- location x/q input to be included 0
- location name, compartment number and x/q table LPZ 2
2
- br model 1
4 0 0.00035 8 0.00018 24 0.00023 720 0.00023
- of model 0
- location x/q input to be included 0
- location name, compartment number and x/q table Control Room 3
0
- br model 1
2 0 0.00035 720 0.00035
- of model 1
4 0 1 24 0.6 96 0.4 720 0.4
- location x/q input to be included 1
- number of intake combinations 3
- intake combinations 2 1 3 3 1 4 4 1 3
- time step count 1
0 0.02
- show plant, scenario, event, step, model 1
1 1
0 1
RADTRAD-NAI Version 1.1a(QA) run on Jun 9, 2005 at 07:02:13 Plant Description
Numerical Applications Inc. Attachment 5 Page 89 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Number of Nuclides = 107 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.0000E+00 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00)
Name: PCS Compartment volume = 4.5945E+05 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Small Line Break Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Unfiltered Makeup Pathway to compartment number 3: Control Room Filtered Makeup Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Small Line Break Pathway from compartment number 3: Control Room Exhaust Compartment number 3 Name: Control Room Compartment volume = 3.5923E+04 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust Pathway from compartment number 2: Control Room Unfiltered Makeup Pathway from compartment number 2: Control Room Filtered Makeup Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 5 RADTRAD-NAI Version 1.1a(QA) run on Jun 9, 2005 at 07:02:13 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Iodine fractions Aerosol = 0.0000E+00 Elemental = 9.7000E-01 Organic = 3.0000E-02 COMPARTMENT DATA Compartment number 1: PCS Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 PATHWAY DATA
Numerical Applications Inc. Attachment 5 Page 90 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Pathway number 1: Small Line Break Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 1.3148E+02 0.0000E+00 0.0000E+00 0.0000E+00 1.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: Control Room Unfiltered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: Control Room Filtered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 Pathway number 4: Control Room Unfiltered Inleakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 5: Control Room Exhaust Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.5136E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.5136E+03 0.0000E+00 0.0000E+00 0.0000E+00 X/Q DATA X/Q table 1: EAB Time (hr) X/Q (s
- m^-3) 0.0000E+00 5.3900E-04 7.2000E+02 5.3900E-04 X/Q table 2: LPZ Time (hr) X/Q (s
- m^-3) 0.0000E+00 6.6600E-05 2.0000E+00 3.0300E-05 8.0000E+00 2.0400E-05 2.4000E+01 8.6700E-06 9.6000E+01 2.5400E-06 7.2000E+02 2.5400E-06 X/Q table 3: Control Room Unfiltered Time (hr) X/Q (s
- m^-3) 0.0000E+00 6.1000E-03 2.0000E+00 4.3200E-03 8.0000E+00 1.7300E-03 2.4000E+01 1.2700E-03
Numerical Applications Inc. Attachment 5 Page 91 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 9.6000E+01 9.7900E-04 7.2000E+02 9.7900E-04 X/Q table 4: Control Room Filtered Time (hr) X/Q (s
- m^-3) 0.0000E+00 8.3200E-04 2.0000E+00 7.6900E-04 8.0000E+00 2.8300E-04 2.4000E+01 2.1500E-04 9.6000E+01 1.5700E-04 7.2000E+02 1.5700E-04 LOCATION DATA Location EAB is in compartment 2 Using X/Q Table 1 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location LPZ is in compartment 2 Using X/Q Table 2 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location Control Room is in compartment 3 Inleakage X/Q Table Assignments Inleakage Path Source Path X/Q Table 2 1 3 3 1 4 4 1 3 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 3.5000E-04 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 4.0000E-01 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 2.0000E-02 RADTRAD-NAI Version 1.1a(QA) run on Jun 9, 2005 at 07:02:13
Numerical Applications Inc. Attachment 5 Page 92 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Dose, Detailed Model and Detailed Inventory Output Detailed model information at time (H) = 0.0100 EAB Doses:
Time (h) = 0.0100 Whole Body Thyroid Skin TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 LPZ Doses:
Time (h) = 0.0100 Whole Body Thyroid Skin TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Control Room Doses:
Time (h) = 0.0100 Whole Body Thyroid Skin TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 PCS Transport Group Inventory:
Overlying Time (h) = 0.0100 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0100 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Transport Group Inventory:
Present Release Integral Time (h) = 0.0100 Release Rate/s Release Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Numerical Applications Inc. Attachment 5 Page 93 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Transport Group Inventory:
Overlying Time (h) = 0.0100 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0100 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00
Numerical Applications Inc. Attachment 5 Page 94 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.0100 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 0.3333 EAB Doses:
Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.0993E-03 1.2321E+00 6.0826E-03 4.2699E-02 Accumulated dose (rem) 4.0993E-03 1.2321E+00 6.0826E-03 4.2699E-02 LPZ Doses:
Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.0652E-04 1.5225E-01 7.5158E-04 5.2760E-03 Accumulated dose (rem) 5.0652E-04 1.5225E-01 7.5158E-04 5.2760E-03 Control Room Doses:
Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.4854E-04 1.5241E+00 7.4642E-03 4.7890E-02 Accumulated dose (rem) 1.4854E-04 1.5241E+00 7.4642E-03 4.7890E-02 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 0.3333 Ci kg Atoms Bq I-131 1.6774E+03 1.3530E-05 6.2199E+19 6.2064E+13 I-132 2.0871E+03 2.0220E-07 9.2248E+17 7.7224E+13 I-133 2.5767E+03 2.2746E-06 1.0299E+19 9.5337E+13 I-134 1.6444E+03 6.1642E-08 2.7703E+17 6.0843E+13 I-135 1.9257E+03 5.4833E-07 2.4460E+18 7.1249E+13 Xe-133 2.3662E+00 1.2641E-08 5.7239E+16 8.7550E+10 Xe-135 2.2230E+01 8.7050E-09 3.8832E+16 8.2252E+11 Xe-131m 7.7378E-03 9.2380E-11 4.2467E+14 2.8630E+08 Xe-133m 1.6927E-01 3.7724E-10 1.7081E+15 6.2630E+09 Xe-135m 1.0821E+02 1.1880E-09 5.2993E+15 4.0039E+12 PCS Transport Group Inventory:
Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 1.0350E+17 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.6617E-05 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Numerical Applications Inc. Attachment 5 Page 95 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 0.3333 Ci kg Atoms Bq I-131 4.6520E+00 3.7524E-08 1.7250E+17 1.7212E+11 I-132 5.7883E+00 5.6077E-10 2.5584E+15 2.1417E+11 I-133 7.1460E+00 6.3082E-09 2.8563E+16 2.6440E+11 I-134 4.5605E+00 1.7095E-10 7.6829E+14 1.6874E+11 I-135 5.3405E+00 1.5207E-09 6.7836E+15 1.9760E+11 Xe-133 8.6270E-03 4.6089E-11 2.0869E+14 3.1920E+08 Xe-135 8.1452E-02 3.1895E-11 1.4228E+14 3.0137E+09 Xe-131m 2.8200E-05 3.3667E-13 1.5477E+12 1.0434E+06 Xe-133m 6.1706E-04 1.3752E-12 6.2268E+12 2.2831E+07 Xe-135m 3.8059E-01 4.1781E-12 1.8638E+13 1.4082E+10 Environment Transport Group Inventory:
Present Release Integral Time (h) = 0.3333 Release Rate/s Release Noble gases (atoms) 2.3565E+13 3.2729E+11 3.7738E+14 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.7108E-09 5.1539E-11 4.6084E-08 Small Line Break Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 0.3333 Ci kg Atoms Bq I-131 7.8892E-03 6.3636E-11 2.9254E+14 2.9190E+08 I-132 9.8163E-03 9.5099E-13 4.3387E+12 3.6320E+08 I-133 1.2119E-02 1.0698E-11 4.8440E+13 4.4839E+08
Numerical Applications Inc. Attachment 5 Page 96 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 I-134 7.7340E-03 2.8992E-13 1.3029E+12 2.8616E+08 I-135 9.0568E-03 2.5789E-12 1.1504E+13 3.3510E+08 Xe-133 1.4428E-05 7.7079E-14 3.4901E+11 5.3383E+05 Xe-135 1.3617E-04 5.3323E-14 2.3787E+11 5.0384E+06 Xe-131m 4.7164E-08 5.6307E-16 2.5885E+09 1.7451E+03 Xe-133m 1.0320E-06 2.2999E-15 1.0414E+10 3.8184E+04 Xe-135m 6.3819E-04 7.0060E-15 3.1253E+10 2.3613E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 6.3113E+11 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 7.8153E-11 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 1.0000 EAB Doses:
Time (h) = 1.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.8899E-02 1.0216E+01 4.3173E-02 3.4833E-01 Accumulated dose (rem) 3.2999E-02 1.1449E+01 4.9256E-02 3.9103E-01 LPZ Doses:
Time (h) = 1.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.5708E-03 1.2624E+00 5.3346E-03 4.3041E-02 Accumulated dose (rem) 4.0774E-03 1.4146E+00 6.0862E-03 4.8317E-02
Numerical Applications Inc. Attachment 5 Page 97 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Control Room Doses:
Time (h) = 1.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.6039E-04 5.2667E+00 2.3293E-02 1.6518E-01 Accumulated dose (rem) 6.0892E-04 6.7908E+00 3.0757E-02 2.1307E-01 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 1.0000 Ci kg Atoms Bq I-131 5.0950E+03 4.1097E-05 1.8893E+20 1.8852E+14 I-132 5.1980E+03 5.0358E-07 2.2975E+18 1.9233E+14 I-133 7.6729E+03 6.7734E-06 3.0669E+19 2.8390E+14 I-134 2.9555E+03 1.1079E-07 4.9790E+17 1.0935E+14 I-135 5.4672E+03 1.5568E-06 6.9445E+18 2.0229E+14 Xe-133 2.0851E+01 1.1139E-07 5.0438E+17 7.7148E+11 Xe-135 1.9613E+02 7.6801E-08 3.4260E+17 7.2567E+12 Xe-131m 6.9132E-02 8.2534E-10 3.7941E+15 2.5579E+09 Xe-133m 1.4889E+00 3.3182E-09 1.5024E+16 5.5088E+10 Xe-135m 5.8554E+02 6.4279E-09 2.8674E+16 2.1665E+13 PCS Transport Group Inventory:
Overlying Time (h) = 1.0000 Atmosphere Sump Pool Noble gases (atoms) 8.9447E+17 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 5.0042E-05 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 1.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 1.0000 Ci kg Atoms Bq I-131 4.3392E+01 3.5001E-07 1.6090E+18 1.6055E+12 I-132 4.4270E+01 4.2888E-09 1.9566E+16 1.6380E+12 I-133 6.5347E+01 5.7686E-08 2.6120E+17 2.4178E+12 I-134 2.5171E+01 9.4354E-10 4.2404E+15 9.3131E+11 I-135 4.6562E+01 1.3258E-08 5.9144E+16 1.7228E+12 Xe-133 2.3640E-01 1.2629E-09 5.7185E+15 8.7467E+09 Xe-135 2.2411E+00 8.7760E-10 3.9148E+15 8.2922E+10 Xe-131m 7.8289E-04 9.3467E-12 4.2967E+13 2.8967E+07 Xe-133m 1.6875E-02 3.7607E-11 1.7028E+14 6.2436E+08 Xe-135m 6.0334E+00 6.6234E-11 2.9546E+14 2.2324E+11 Environment Transport Group Inventory:
Present Release Integral Time (h) = 1.0000 Release Rate/s Release Noble gases (atoms) 3.0707E+14 4.2648E+12 1.0142E+16 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.7000E-08 2.3611E-10 4.2618E-07 Small Line Break Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter
Numerical Applications Inc. Attachment 5 Page 98 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 1.0000 Ci kg Atoms Bq I-131 2.1308E-02 1.7187E-10 7.9011E+14 7.8840E+08 I-132 2.1739E-02 2.1061E-12 9.6083E+12 8.0434E+08 I-133 3.2089E-02 2.8327E-11 1.2826E+14 1.1873E+09 I-134 1.2360E-02 4.6333E-13 2.0823E+12 4.5733E+08 I-135 2.2865E-02 6.5107E-12 2.9043E+13 8.4599E+08 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.0928E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 1.0000 Ci kg Atoms Bq I-131 4.4685E-03 3.6043E-11 1.6569E+14 1.6533E+08 I-132 4.5588E-03 4.4166E-13 2.0149E+12 1.6868E+08 I-133 6.7294E-03 5.9404E-12 2.6898E+13 2.4899E+08 I-134 2.5920E-03 9.7165E-14 4.3667E+11 9.5905E+07 I-135 4.7949E-03 1.3653E-12 6.0906E+12 1.7741E+08 Xe-133 1.1715E-04 6.2589E-13 2.8340E+12 4.3347E+06 Xe-135 1.1000E-03 4.3073E-13 1.9214E+12 4.0698E+07 Xe-131m 3.8850E-07 4.6381E-15 2.1322E+10 1.4374E+04 Xe-133m 8.3660E-06 1.8645E-14 8.4422E+10 3.0954E+05 Xe-135m 3.3603E-03 3.6889E-14 1.6456E+11 1.2433E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 1.0000 Atmosphere Sump Pool Noble gases (atoms) 5.0257E+12 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 4.3888E-11 0.0000E+00 0.0000E+00
Numerical Applications Inc. Attachment 5 Page 99 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Recirculating Filter Inventory Time (h) = 1.0000 Ci kg Atoms Bq I-131 7.1032E-03 5.7295E-11 2.6339E+14 2.6282E+08 I-132 7.2468E-03 7.0206E-13 3.2030E+12 2.6813E+08 I-133 1.0697E-02 9.4430E-12 4.2757E+13 3.9579E+08 I-134 4.1203E-03 1.5445E-13 6.9414E+11 1.5245E+08 I-135 7.6220E-03 2.1704E-12 9.6817E+12 2.8202E+08 Deposition Recirculating Time (h) = 1.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 6.9765E-11 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 1.0000 Ci kg Atoms Bq I-131 2.1308E-02 1.7187E-10 7.9011E+14 7.8840E+08 I-132 2.1739E-02 2.1061E-12 9.6083E+12 8.0434E+08 I-133 3.2089E-02 2.8327E-11 1.2826E+14 1.1873E+09 I-134 1.2360E-02 4.6333E-13 2.0823E+12 4.5733E+08 I-135 2.2865E-02 6.5107E-12 2.9043E+13 8.4599E+08 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.0928E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 1.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Time (h) = 1.0000 Ci kg Atoms Bq I-131 2.8411E-02 2.2917E-10 1.0535E+15 1.0512E+09 I-132 2.8986E-02 2.8081E-12 1.2811E+13 1.0725E+09 I-133 4.2786E-02 3.7770E-11 1.7102E+14 1.5831E+09 I-134 1.6481E-02 6.1779E-13 2.7764E+12 6.0978E+08 I-135 3.0487E-02 8.6811E-12 3.8725E+13 1.1280E+09 Detailed model information at time (H) = 2.0000 EAB Doses:
Numerical Applications Inc. Attachment 5 Page 100 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.8107E-06 6.0347E-04 2.7732E-06 2.0650E-05 Accumulated dose (rem) 3.3000E-02 1.1449E+01 4.9259E-02 3.9105E-01 LPZ Doses:
Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.2374E-07 7.4566E-05 3.4266E-07 2.5516E-06 Accumulated dose (rem) 4.0776E-03 1.4147E+00 6.0865E-03 4.8319E-02 Control Room Doses:
Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.3901E-04 1.5686E+00 7.2074E-03 4.9108E-02 Accumulated dose (rem) 7.4794E-04 8.3594E+00 3.7964E-02 2.6218E-01 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 2.0000 Ci kg Atoms Bq I-131 1.0248E+04 8.2666E-05 3.8002E+20 3.7919E+14 I-132 7.7630E+03 7.5208E-07 3.4311E+18 2.8723E+14 I-133 1.4982E+04 1.3225E-05 5.9883E+19 5.5432E+14 I-134 2.7059E+03 1.0143E-07 4.5586E+17 1.0012E+14 I-135 9.9379E+03 2.8298E-06 1.2623E+19 3.6770E+14 Xe-133 8.1806E+01 4.3704E-07 1.9789E+18 3.0268E+12 Xe-135 7.3982E+02 2.8970E-07 1.2923E+18 2.7373E+13 Xe-131m 2.7690E-01 3.3058E-09 1.5197E+16 1.0245E+10 Xe-133m 5.8256E+00 1.2983E-08 5.8787E+16 2.1555E+11 Xe-135m 1.3299E+03 1.4599E-08 6.5125E+16 4.9206E+13 PCS Transport Group Inventory:
Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 3.4103E+18 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 9.9574E-05 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 2.0000 Ci kg Atoms Bq I-131 4.3239E+01 3.4877E-07 1.6033E+18 1.5998E+12 I-132 3.2753E+01 3.1730E-09 1.4476E+16 1.2118E+12 I-133 6.3209E+01 5.5798E-08 2.5265E+17 2.3387E+12 I-134 1.1417E+01 4.2796E-10 1.9233E+15 4.2241E+11 I-135 4.1929E+01 1.1939E-08 5.3259E+16 1.5514E+12 Xe-133 5.7824E-01 3.0892E-09 1.3988E+16 2.1395E+10 Xe-135 5.3050E+00 2.0773E-09 9.2667E+15 1.9628E+11 Xe-131m 1.9474E-03 2.3249E-11 1.0688E+14 7.2054E+07 Xe-133m 4.1116E-02 9.1632E-11 4.1490E+14 1.5213E+09 Xe-135m 6.7952E+00 7.4596E-11 3.3276E+14 2.5142E+11 Environment Transport Group Inventory:
Present Release Integral
Numerical Applications Inc. Attachment 5 Page 101 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 2.0000 Release Rate/s Release Noble gases (atoms) 2.0473E+11 2.8435E+09 2.4109E+16 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.7707E-14 2.4593E-16 4.2011E-07 Small Line Break Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq I-131 2.1232E-02 1.7126E-10 7.8728E+14 7.8557E+08 I-132 1.6083E-02 1.5581E-12 7.1083E+12 5.9506E+08 I-133 3.1038E-02 2.7399E-11 1.2406E+14 1.1484E+09 I-134 5.6059E-03 2.1014E-13 9.4441E+11 2.0742E+08 I-135 2.0588E-02 5.8625E-12 2.6152E+13 7.6177E+08 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.0629E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 2.0000 Ci kg Atoms Bq I-131 3.4319E-05 2.7682E-13 1.2726E+12 1.2698E+06 I-132 2.5996E-05 2.5185E-15 1.1490E+10 9.6185E+05 I-133 5.0169E-05 4.4287E-14 2.0053E+11 1.8563E+06 I-134 9.0614E-06 3.3967E-16 1.5265E+09 3.3527E+05 I-135 3.3279E-05 9.4762E-15 4.2272E+10 1.2313E+06 Xe-133 9.9480E-05 5.3146E-13 2.4064E+12 3.6808E+06 Xe-135 8.7285E-04 3.4179E-13 1.5247E+12 3.2295E+07 Xe-131m 3.3912E-07 4.0487E-15 1.8612E+10 1.2548E+04 Xe-133m 7.0993E-06 1.5822E-14 7.1640E+10 2.6268E+05 Xe-135m 2.5425E-03 2.7911E-14 1.2451E+11 9.4072E+07
Numerical Applications Inc. Attachment 5 Page 102 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Control Room Transport Group Inventory:
Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 4.1459E+12 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.3344E-13 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 2.0000 Ci kg Atoms Bq I-131 9.2019E-03 7.4224E-11 3.4121E+14 3.4047E+08 I-132 6.9703E-03 6.7527E-13 3.0807E+12 2.5790E+08 I-133 1.3452E-02 1.1875E-11 5.3768E+13 4.9772E+08 I-134 2.4296E-03 9.1076E-14 4.0931E+11 8.9896E+07 I-135 8.9231E-03 2.5408E-12 1.1334E+13 3.3015E+08 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 8.9406E-11 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq I-131 2.1232E-02 1.7126E-10 7.8728E+14 7.8557E+08 I-132 1.6083E-02 1.5581E-12 7.1083E+12 5.9506E+08 I-133 3.1038E-02 2.7399E-11 1.2406E+14 1.1484E+09 I-134 5.6059E-03 2.1014E-13 9.4441E+11 2.0742E+08 I-135 2.0588E-02 5.8625E-12 2.6152E+13 7.6177E+08 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.0629E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Numerical Applications Inc. Attachment 5 Page 103 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 2.0000 Ci kg Atoms Bq I-131 3.0434E-02 2.4548E-10 1.1285E+15 1.1260E+09 I-132 2.3053E-02 2.2333E-12 1.0189E+13 8.5296E+08 I-133 4.4489E-02 3.9273E-11 1.7783E+14 1.6461E+09 I-134 8.0355E-03 3.0122E-13 1.3537E+12 2.9731E+08 I-135 2.9511E-02 8.4034E-12 3.7486E+13 1.0919E+09 Detailed model information at time (H) = 8.0000 EAB Doses:
Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.3695E-06 4.6268E-06 2.2637E-06 1.5136E-06 Accumulated dose (rem) 3.3002E-02 1.1449E+01 4.9261E-02 3.9105E-01 LPZ Doses:
Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 7.6986E-08 2.6010E-07 1.2726E-07 8.5085E-08 Accumulated dose (rem) 4.0777E-03 1.4147E+00 6.0866E-03 4.8319E-02 Control Room Doses:
Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.0509E-04 1.2026E-02 5.8806E-03 4.7959E-04 Accumulated dose (rem) 8.5302E-04 8.3714E+00 4.3845E-02 2.6266E-01 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 8.0000 Ci kg Atoms Bq I-131 4.0399E+04 3.2586E-04 1.4980E+21 1.4947E+15 I-132 5.1263E+03 4.9663E-07 2.2657E+18 1.8967E+14 I-133 4.9408E+04 4.3615E-05 1.9749E+20 1.8281E+15 I-134 9.4865E+01 3.5561E-09 1.5982E+16 3.5100E+12 I-135 2.1336E+04 6.0754E-06 2.7102E+19 7.8944E+14 Xe-133 1.1412E+03 6.0965E-06 2.7605E+19 4.2223E+13 Xe-135 6.9765E+03 2.7319E-06 1.2187E+19 2.5813E+14 Xe-131m 4.3682E+00 5.2150E-08 2.3974E+17 1.6162E+11 Xe-133m 7.9910E+01 1.7809E-07 8.0638E+17 2.9567E+12 Xe-135m 3.3475E+03 3.6748E-08 1.6393E+17 1.2386E+14 PCS Transport Group Inventory:
Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 4.1001E+19 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.7605E-04 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 8.0000 Ci kg Atoms Bq Xe-133 2.3712E+00 1.2668E-08 5.7358E+16 8.7733E+10 Xe-135 1.4598E+01 5.7163E-09 2.5500E+16 5.4013E+11 Xe-131m 8.7882E-03 1.0492E-10 4.8232E+14 3.2516E+08 Xe-133m 1.6443E-01 3.6646E-10 1.6593E+15 6.0840E+09
Numerical Applications Inc. Attachment 5 Page 104 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Xe-135m 3.6793E+00 4.0391E-11 1.8018E+14 1.3613E+11 Environment Transport Group Inventory:
Present Release Integral Time (h) = 8.0000 Release Rate/s Release Noble gases (atoms) 1.4169E+11 1.9679E+09 8.5180E+16 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.4816E-27 4.8356E-29 3.9391E-07 Small Line Break Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq I-131 2.0779E-02 1.6761E-10 7.7049E+14 7.6882E+08 I-132 2.6367E-03 2.5544E-13 1.1654E+12 9.7558E+07 I-133 2.5413E-02 2.2433E-11 1.0158E+14 9.4027E+08 I-134 4.8794E-05 1.8291E-15 8.2201E+09 1.8054E+06 I-135 1.0974E-02 3.1249E-12 1.3940E+13 4.0604E+08 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.9342E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 8.0000 Ci kg Atoms Bq Xe-133 7.9944E-05 4.2709E-13 1.9338E+12 2.9579E+06 Xe-135 4.5606E-04 1.7858E-13 7.9664E+11 1.6874E+07 Xe-131m 3.2582E-07 3.8898E-15 1.7882E+10 1.2055E+04 Xe-133m 5.7055E-06 1.2715E-14 5.7575E+10 2.1110E+05 Xe-135m 1.3503E-03 1.4823E-14 6.6125E+10 4.9961E+07
Numerical Applications Inc. Attachment 5 Page 105 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Control Room Transport Group Inventory:
Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 2.8721E+12 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 6.5563E-26 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 8.0000 Ci kg Atoms Bq I-131 9.0218E-03 7.2771E-11 3.3453E+14 3.3381E+08 I-132 1.1448E-03 1.1091E-13 5.0599E+11 4.2358E+07 I-133 1.1034E-02 9.7402E-12 4.4103E+13 4.0825E+08 I-134 2.1185E-05 7.9415E-16 3.5690E+09 7.8386E+05 I-135 4.7648E-03 1.3568E-12 6.0523E+12 1.7630E+08 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 8.3980E-11 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq I-131 2.0779E-02 1.6761E-10 7.7049E+14 7.6882E+08 I-132 2.6367E-03 2.5544E-13 1.1654E+12 9.7558E+07 I-133 2.5413E-02 2.2433E-11 1.0158E+14 9.4027E+08 I-134 4.8794E-05 1.8291E-15 8.2201E+09 1.8054E+06 I-135 1.0974E-02 3.1249E-12 1.3940E+13 4.0604E+08 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.9342E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Numerical Applications Inc. Attachment 5 Page 106 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 8.0000 Ci kg Atoms Bq I-131 2.9801E-02 2.4038E-10 1.1050E+15 1.1026E+09 I-132 3.7815E-03 3.6635E-13 1.6714E+12 1.3992E+08 I-133 3.6447E-02 3.2174E-11 1.4568E+14 1.3485E+09 I-134 6.9979E-05 2.6232E-15 1.1789E+10 2.5892E+06 I-135 1.5739E-02 4.4817E-12 1.9992E+13 5.8234E+08 Detailed model information at time (H) = 24.0000 EAB Doses:
Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.2666E-06 4.6694E-19 2.1017E-06 1.2666E-06 Accumulated dose (rem) 3.3003E-02 1.1449E+01 4.9263E-02 3.9106E-01 LPZ Doses:
Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.7937E-08 1.7673E-20 7.9544E-08 4.7937E-08 Accumulated dose (rem) 4.0777E-03 1.4147E+00 6.0867E-03 4.8319E-02 Control Room Doses:
Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.7192E-05 2.3600E-15 5.4597E-03 9.7192E-05 Accumulated dose (rem) 9.5022E-04 8.3714E+00 4.9304E-02 2.6276E-01 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 24.0000 Ci kg Atoms Bq I-131 3.8142E+04 3.0766E-04 1.4143E+21 1.4113E+15 I-132 4.1275E+01 3.9986E-09 1.8243E+16 1.5272E+12 I-133 2.8989E+04 2.5590E-05 1.1587E+20 1.0726E+15 I-134 3.0410E-04 1.1400E-14 5.1231E+10 1.1252E+07 I-135 3.9852E+03 1.1348E-06 5.0621E+18 1.4745E+14 Xe-133 4.1850E+03 2.2358E-05 1.0123E+20 1.5484E+14 Xe-135 8.2682E+03 3.2377E-06 1.4443E+19 3.0592E+14 Xe-131m 2.0797E+01 2.4829E-07 1.1414E+18 7.6949E+11 Xe-133m 2.7419E+02 6.1107E-07 2.7669E+18 1.0145E+13 Xe-135m 6.5586E+02 7.1999E-09 3.2118E+16 2.4267E+13 PCS Transport Group Inventory:
Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 1.1962E+20 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.3439E-04 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 24.0000 Ci kg Atoms Bq Xe-133 5.4688E+00 2.9217E-08 1.3229E+17 2.0235E+11 Xe-135 1.0819E+01 4.2366E-09 1.8899E+16 4.0030E+11 Xe-131m 2.5849E-02 3.0860E-10 1.4187E+15 9.5641E+08 Xe-133m 3.5272E-01 7.8609E-10 3.5594E+15 1.3051E+10
Numerical Applications Inc. Attachment 5 Page 107 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Xe-135m 6.8723E-01 7.5443E-12 3.3654E+13 2.5427E+10 Environment Transport Group Inventory:
Present Release Integral Time (h) = 24.0000 Release Rate/s Release Noble gases (atoms) 6.6424E+10 9.2255E+08 1.5620E+17 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 3.5027E-07 Small Line Break Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 24.0000 Ci kg Atoms Bq I-131 1.9618E-02 1.5824E-10 7.2746E+14 7.2588E+08 I-132 2.1229E-05 2.0567E-15 9.3831E+09 7.8549E+05 I-133 1.4910E-02 1.3162E-11 5.9598E+13 5.5169E+08 I-135 2.0498E-03 5.8367E-13 2.6037E+12 7.5842E+07 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.7199E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 24.0000 Ci kg Atoms Bq Xe-133 4.6905E-05 2.5059E-13 1.1346E+12 1.7355E+06 Xe-135 8.5183E-05 3.3356E-14 1.4880E+11 3.1518E+06 Xe-131m 3.0762E-07 3.6726E-15 1.6883E+10 1.1382E+04 Xe-133m 3.3476E-06 7.4605E-15 3.3781E+10 1.2386E+05 Xe-135m 2.5221E-04 2.7688E-15 1.2351E+10 9.3319E+06
Numerical Applications Inc. Attachment 5 Page 108 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Control Room Transport Group Inventory:
Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 1.3465E+12 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 24.0000 Ci kg Atoms Bq I-131 8.5179E-03 6.8707E-11 3.1585E+14 3.1516E+08 I-132 9.2174E-06 8.9298E-16 4.0740E+09 3.4105E+05 I-133 6.4738E-03 5.7148E-12 2.5876E+13 2.3953E+08 I-135 8.8997E-04 2.5342E-13 1.1305E+12 3.2929E+07 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 7.4676E-11 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 24.0000 Ci kg Atoms Bq I-131 1.9618E-02 1.5824E-10 7.2746E+14 7.2588E+08 I-132 2.1229E-05 2.0567E-15 9.3831E+09 7.8549E+05 I-133 1.4910E-02 1.3162E-11 5.9598E+13 5.5169E+08 I-135 2.0498E-03 5.8367E-13 2.6037E+12 7.5842E+07 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.7199E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Time (h) = 24.0000 Ci kg Atoms Bq I-131 2.8136E-02 2.2695E-10 1.0433E+15 1.0410E+09 I-132 3.0447E-05 2.9497E-15 1.3457E+10 1.1265E+06
Numerical Applications Inc. Attachment 5 Page 109 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 I-133 2.1384E-02 1.8877E-11 8.5475E+13 7.9122E+08 I-135 2.9397E-03 8.3709E-13 3.7341E+12 1.0877E+08 Detailed model information at time (H) = 96.0000 EAB Doses:
Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.9937E-07 8.1025E-53 5.1246E-07 2.9937E-07 Accumulated dose (rem) 3.3003E-02 1.1449E+01 4.9264E-02 3.9106E-01 LPZ Doses:
Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.8155E-09 1.3033E-54 8.2431E-09 4.8155E-09 Accumulated dose (rem) 4.0777E-03 1.4147E+00 6.0867E-03 4.8319E-02 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.3783E-05 1.9229E-49 7.9875E-04 1.3783E-05 Accumulated dose (rem) 9.6400E-04 8.3714E+00 5.0103E-02 2.6277E-01 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq I-131 2.9450E+04 2.3755E-04 1.0920E+21 1.0896E+15 I-132 1.5564E-08 1.5079E-18 6.8793E+06 5.7589E+02 I-133 2.6315E+03 2.3230E-06 1.0518E+19 9.7366E+13 I-135 2.0963E+00 5.9692E-10 2.6628E+15 7.7563E+10 Xe-133 6.1633E+03 3.2927E-05 1.4909E+20 2.2804E+14 Xe-135 7.2638E+01 2.8444E-08 1.2688E+17 2.6876E+12 Xe-131m 7.7051E+01 9.1989E-07 4.2288E+18 2.8509E+12 Xe-133m 2.6914E+02 5.9980E-07 2.7159E+18 9.9580E+12 Xe-135m 3.4499E-01 3.7873E-12 1.6895E+13 1.2765E+10 PCS Transport Group Inventory:
Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 1.5616E+20 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 2.3987E-04 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 96.0000 Ci kg Atoms Bq Xe-133 7.2018E+00 3.8475E-08 1.7421E+17 2.6647E+11 Xe-135 8.5023E-02 3.3294E-11 1.4852E+14 3.1458E+09 Xe-131m 8.4166E-02 1.0048E-09 4.6193E+15 3.1141E+09 Xe-133m 3.0736E-01 6.8500E-10 3.1016E+15 1.1372E+10 Xe-135m 3.6150E-04 3.9685E-15 1.7703E+10 1.3375E+07 Environment Transport Group Inventory:
Present Release Integral
Numerical Applications Inc. Attachment 5 Page 110 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Time (h) = 96.0000 Release Rate/s Release Noble gases (atoms) 5.8793E+09 8.1657E+07 1.8208E+17 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 2.5126E-07 Small Line Break Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 96.0000 Ci kg Atoms Bq I-131 1.5147E-02 1.2218E-10 5.6167E+14 5.6045E+08 I-133 1.3535E-03 1.1948E-12 5.4101E+12 5.0080E+07 I-135 1.0782E-06 3.0703E-16 1.3696E+09 3.9894E+04 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.2338E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Xe-133 4.2579E-06 2.2747E-14 1.0300E+11 1.5754E+05 Xe-135 4.4808E-08 1.7546E-17 7.8271E+07 1.6579E+03 Xe-131m 2.3751E-07 2.8356E-15 1.3035E+10 8.7880E+03 Xe-133m 3.0388E-07 6.7724E-16 3.0665E+09 1.1244E+04 Xe-135m 1.3267E-07 1.4564E-18 6.4969E+06 4.9088E+03 Control Room Transport Group Inventory:
Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 1.1919E+11 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00
Numerical Applications Inc. Attachment 5 Page 111 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 96.0000 Ci kg Atoms Bq I-131 6.5767E-03 5.3049E-11 2.4387E+14 2.4334E+08 I-133 5.8767E-04 5.1877E-13 2.3490E+12 2.1744E+07 I-135 4.6815E-07 1.3330E-16 5.9465E+08 1.7321E+04 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 5.3568E-11 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 96.0000 Ci kg Atoms Bq I-131 1.5147E-02 1.2218E-10 5.6167E+14 5.6045E+08 I-133 1.3535E-03 1.1948E-12 5.4101E+12 5.0080E+07 I-135 1.0782E-06 3.0703E-16 1.3696E+09 3.9894E+04 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.2338E-10 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq I-131 2.1724E-02 1.7523E-10 8.0554E+14 8.0379E+08 I-133 1.9412E-03 1.7136E-12 7.7591E+12 7.1824E+07 I-135 1.5464E-06 4.4033E-16 1.9642E+09 5.7216E+04 Detailed model information at time (H) = 720.0000 EAB Doses:
Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.3068E-09 4.0677-205 5.2404E-09 1.3068E-09
Numerical Applications Inc. Attachment 5 Page 112 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Accumulated dose (rem) 3.3003E-02 1.1449E+01 4.9264E-02 3.9106E-01 LPZ Doses:
Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 6.1581E-12 1.9169-207 2.4695E-11 6.1581E-12 Accumulated dose (rem) 4.0777E-03 1.4147E+00 6.0867E-03 4.8319E-02 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.0111E-08 6.4357-202 5.4453E-06 4.0111E-08 Accumulated dose (rem) 9.6404E-04 8.3714E+00 5.0109E-02 2.6277E-01 PCS Compartment Atmosphere Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq I-131 3.1304E+03 2.5250E-05 1.1608E+20 1.1583E+14 I-133 2.4508E-06 2.1635E-15 9.7960E+09 9.0679E+04 Xe-133 2.2168E+02 1.1843E-06 5.3623E+18 8.2020E+12 Xe-131m 9.4320E+01 1.1261E-06 5.1765E+18 3.4898E+12 Xe-133m 8.4512E-02 1.8835E-10 8.5282E+14 3.1270E+09 PCS Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 1.0540E+19 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 2.5250E-05 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Small Line Break Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:
Time (h) = 720.0000 Ci kg Atoms Bq Xe-131m 9.9616E-02 1.1893E-09 5.4672E+15 3.6858E+09 Environment Transport Group Inventory:
Present Release Integral Time (h) = 720.0000 Release Rate/s Release Noble gases (atoms) 6.8319E+07 9.4887E+05 1.1680E+16 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 2.6449E-08 Small Line Break Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:
Numerical Applications Inc. Attachment 5 Page 113 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 720.0000 Ci kg Atoms Bq I-131 1.6101E-03 1.2987E-11 5.9704E+13 5.9574E+07 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.2987E-11 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Xe-131m 2.5247E-08 3.0141E-16 1.3856E+09 9.3413E+02 Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 1.3856E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 720.0000 Ci kg Atoms Bq I-131 6.9908E-04 5.6389E-12 2.5922E+13 2.5866E+07 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 5.6389E-12 Control Room Unfiltered Makeup Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00
Numerical Applications Inc. Attachment 5 Page 114 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 720.0000 Ci kg Atoms Bq I-131 1.6101E-03 1.2987E-11 5.9704E+13 5.9574E+07 Control Room Filtered Makeup Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.2987E-11 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq I-131 2.3092E-03 1.8626E-11 8.5626E+13 8.5440E+07 Transport Group Totals in Model:
Noble Gases (atoms) 1.0551E+19 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.5277E-05 36005 I-131 Summary PCS Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.001 0.0000E+00 0.0000E+00 0.0000E+00 0.010 0.0000E+00 0.0000E+00 0.0000E+00 0.280 1.4018E+03 3.2461E+00 5.6082E-03 0.333 1.6774E+03 4.6520E+00 7.8892E-03 0.600 3.0512E+03 1.5467E+01 4.0412E-03 0.860 4.3819E+03 3.2029E+01 4.0029E-03 1.000 5.0950E+03 4.3392E+01 4.4685E-03 1.260 6.4385E+03 4.3353E+01 1.2600E-03 1.520 7.7794E+03 4.3313E+01 3.5527E-04 1.780 9.1179E+03 4.3273E+01 1.0017E-04 2.000 1.0248E+04 4.3239E+01 3.4319E-05 2.260 1.1582E+04 4.3198E+01 9.6768E-06 2.520 1.2914E+04 4.3158E+01 2.7285E-06 2.780 1.4242E+04 4.3118E+01 7.6935E-07 3.040 1.5569E+04 4.3078E+01 2.1693E-07 3.300 1.6893E+04 4.3037E+01 6.1167E-08 3.560 1.8214E+04 4.2997E+01 1.7247E-08 3.820 1.9533E+04 4.2957E+01 4.8631E-09
Numerical Applications Inc. Attachment 5 Page 115 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 4.080 2.0849E+04 4.2917E+01 1.3712E-09 4.340 2.2163E+04 4.2877E+01 3.8664E-10 4.600 2.3475E+04 4.2837E+01 1.0902E-10 4.860 2.4784E+04 4.2797E+01 3.0740E-11 5.120 2.6090E+04 4.2757E+01 8.6677E-12 5.380 2.7394E+04 4.2717E+01 2.4440E-12 5.640 2.8696E+04 4.2677E+01 6.8912E-13 5.900 2.9995E+04 4.2637E+01 1.9431E-13 6.160 3.1292E+04 4.2598E+01 5.4789E-14 6.420 3.2586E+04 4.2558E+01 1.5449E-14 6.680 3.3878E+04 4.2518E+01 4.3560E-15 6.940 3.5167E+04 4.2478E+01 1.2282E-15 7.200 3.6454E+04 4.2439E+01 3.4632E-16 7.460 3.7739E+04 4.2399E+01 9.7651E-17 7.720 3.9021E+04 4.2359E+01 2.7534E-17 7.980 4.0300E+04 4.2320E+01 7.7638E-18 8.000 4.0399E+04 4.2317E+01 7.0434E-18 8.260 4.0361E+04 4.2277E+01 1.9860E-18 8.520 4.0323E+04 4.2238E+01 5.5998E-19 8.780 4.0286E+04 4.2198E+01 1.5790E-19 9.040 4.0248E+04 4.2159E+01 4.4521E-20 9.300 4.0210E+04 4.2120E+01 1.2554E-20 9.560 4.0173E+04 4.2080E+01 3.5397E-21 9.820 4.0135E+04 4.2041E+01 9.9807E-22 10.080 4.0098E+04 4.2002E+01 2.8142E-22 24.000 3.8142E+04 3.9953E+01 1.0322E-51 96.000 2.9450E+04 3.0848E+01 5.7639-204 720.000 3.1304E+03 3.2790E+00 0.0000E+00 Cumulative Dose Summary EAB LPZ Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.001 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.010 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.280 8.6005E-01 2.9844E-02 1.0627E-01 3.6876E-03 9.0172E-01 2.8339E-02 0.333 1.2321E+00 4.2699E-02 1.5225E-01 5.2760E-03 1.5241E+00 4.7890E-02 0.600 4.0902E+00 1.4086E-01 5.0540E-01 1.7405E-02 4.0279E+00 1.2648E-01 0.860 8.4571E+00 2.8965E-01 1.0450E+00 3.5790E-02 5.7712E+00 1.8113E-01 1.000 1.1449E+01 3.9103E-01 1.4146E+00 4.8317E-02 6.7908E+00 2.1307E-01 1.260 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 7.9269E+00 2.4864E-01 1.520 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.2464E+00 2.5864E-01 1.780 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3363E+00 2.6145E-01 2.000 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3594E+00 2.6218E-01 2.260 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3680E+00 2.6246E-01 2.520 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3705E+00 2.6254E-01 2.780 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3712E+00 2.6257E-01 3.040 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6258E-01 3.300 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6259E-01 3.560 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6259E-01 3.820 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6260E-01 4.080 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6260E-01 4.340 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6261E-01 4.600 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6261E-01 4.860 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6262E-01 5.120 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6262E-01 5.380 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6262E-01 5.640 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6263E-01 5.900 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6263E-01 6.160 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6264E-01 6.420 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6264E-01 6.680 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6264E-01 6.940 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6265E-01 7.200 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6265E-01 7.460 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6266E-01 7.720 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6266E-01 7.980 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6266E-01 8.000 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6266E-01 8.260 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6267E-01 8.520 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6267E-01
Numerical Applications Inc. Attachment 5 Page 116 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 8.780 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6267E-01 9.040 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6267E-01 9.300 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6268E-01 9.560 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6268E-01 9.820 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6268E-01 10.080 1.1449E+01 3.9105E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6269E-01 24.000 1.1449E+01 3.9106E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6276E-01 96.000 1.1449E+01 3.9106E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6277E-01 720.000 1.1449E+01 3.9106E-01 1.4147E+00 4.8319E-02 8.3714E+00 2.6277E-01 Worst Two-Hour Dose (Provided for Dose Location 1)
EAB Time Whole Body Thyroid Skin TEDE (hr) (rem) (rem) (rem) (rem) 0.0 3.3000E-02 1.1449E+01 4.9259E-02 3.9105E-01 30 Day Control Room Skin Dose Control Room Time Skin (hr) (rem) 720.0 5.0109E-02
Numerical Applications Inc. Attachment 6 Page 117 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 RADTRAD-NAI Dose Conversion Factor File NAI-1101-001rev0.DCF Includes 107 istopes 9 ORGANS DEFINED IN THIS FILE:
GONADS BREAST LUNGS RED MARR BONE SUR THYROID REMAINDER EFFECTIVE SKIN(FGR) 107 NUCLIDES DEFINED IN THIS FILE:
Co-58 Y Co-60 Y Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 D Sr-89 Y Sr-90 Y Sr-91 Y Sr-92 Y Y-90 Y Y-91 Y Y-92 Y Y-93 Y Zr-95 D Zr-97 Y Nb-95 Y Mo-99 Y Tc-99m D Ru-103 Y Ru-105 Y Ru-106 Y Rh-105 Y Sb-127 W Sb-129 W Te-127 W Te-127m W Te-129 D Te-129m W Te-131m W Te-132 W I-131 D I-132 D I-133 D I-134 D I-135 D Xe-133 Xe-135 Cs-134 D Cs-136 D Cs-137 D Ba-139 D Ba-140 D La-140 W La-141 D La-142 D Ce-141 Y Ce-143 Y Ce-144 Y Pr-143 Y Nd-147 Y Np-239 W Pu-238 W Pu-239 W Pu-240 W Pu-241 W
Numerical Applications Inc. Attachment 6 Page 118 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Am-241 W Cm-242 W Cm-244 W I-130 D Kr-83m Xe-138 Xe-131m Xe-133m Xe-135m Cs-138 D Cs-134m D Rb-88 D Rb-89 D Sb-124 W Sb-125 W Sb-126 W Te-131 D Te-133 D Te-134 D Te-125m W Te-133m D Ba-141 D Ba-137m Pd-109 Y Rh-106 Rh-103m D Tc-101 D Eu-154 W Eu-155 W Eu-156 W La-143 W Nb-97 Y Nb-95m Y Pm-147 Y Pm-148 Y Pm-149 Y Pm-151 Y Pm-148m Y Pr-144 Y Pr-144m Sm-153 W Y-94 Y Y-95 Y Y-91m Y Br-82 W Br-83 W Br-84 D Am-242 W Np-238 W Pu-243 Y CLOUDSHINE GROUND GROUND GROUND INHALED INHALED INGESTION SHINE 8HR SHINE 7DAY SHINE RATE ACUTE CHRONIC Co-58 GONADS 4.660E-14 2.867E-11 5.828E-10 9.970E-16-1.000E+00 6.170E-10 1.040E-09 BREAST 5.300E-14 2.737E-11 5.565E-10 9.520E-16-1.000E+00 9.370E-10 1.790E-10 LUNGS 4.640E-14 2.617E-11 5.319E-10 9.100E-16-1.000E+00 1.600E-08 8.530E-11 RED MARR 4.530E-14 2.671E-11 5.430E-10 9.290E-16-1.000E+00 9.230E-10 2.600E-10 BONE SUR 7.410E-14 3.795E-11 7.716E-10 1.320E-15-1.000E+00 6.930E-10 1.250E-10 THYROID 4.770E-14 2.720E-11 5.530E-10 9.460E-16-1.000E+00 8.720E-10 6.310E-11 REMAINDER 4.440E-14 2.585E-11 5.255E-10 8.990E-16-1.000E+00 1.890E-09 1.580E-09 EFFECTIVE 4.760E-14 2.732E-11 5.553E-10 9.500E-16-1.000E+00 2.940E-09 8.090E-10 SKIN(FGR) 5.580E-14 3.278E-11 6.664E-10 1.140E-15-1.000E+00 0.000E+00 0.000E+00 Co-60 GONADS 1.230E-13 7.056E-11 1.480E-09 2.450E-15-1.000E+00 4.760E-09 3.190E-09 BREAST 1.390E-13 6.739E-11 1.413E-09 2.340E-15-1.000E+00 1.840E-08 1.100E-09 LUNGS 1.240E-13 6.537E-11 1.371E-09 2.270E-15-1.000E+00 3.450E-07 8.770E-10 RED MARR 1.230E-13 6.710E-11 1.407E-09 2.330E-15-1.000E+00 1.720E-08 1.320E-09 BONE SUR 1.780E-13 8.956E-11 1.879E-09 3.110E-15-1.000E+00 1.350E-08 9.390E-10 THYROID 1.270E-13 6.480E-11 1.359E-09 2.250E-15-1.000E+00 1.620E-08 7.880E-10 REMAINDER 1.200E-13 6.508E-11 1.365E-09 2.260E-15-1.000E+00 3.600E-08 4.970E-09 EFFECTIVE 1.260E-13 6.768E-11 1.419E-09 2.350E-15-1.000E+00 5.910E-08 2.770E-09 SKIN(FGR) 1.450E-13 7.948E-11 1.667E-09 2.760E-15-1.000E+00 0.000E+00 0.000E+00 Kr-85
Numerical Applications Inc. Attachment 6 Page 119 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 GONADS 1.170E-16 8.121E-14 1.704E-12 2.820E-18-1.000E+00 0.000E+00 0.000E+00 BREAST 1.340E-16 7.891E-14 1.656E-12 2.740E-18-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.140E-16 7.056E-14 1.481E-12 2.450E-18-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.090E-16 6.998E-14 1.469E-12 2.430E-18-1.000E+00 0.000E+00 0.000E+00 BONE SUR 2.200E-16 1.287E-13 2.702E-12 4.470E-18-1.000E+00 0.000E+00 0.000E+00 THYROID 1.180E-16 7.459E-14 1.565E-12 2.590E-18-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.090E-16 6.941E-14 1.457E-12 2.410E-18-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.190E-16 7.603E-14 1.596E-12 2.640E-18-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.320E-14 2.304E-11 4.835E-10 8.000E-16-1.000E+00 0.000E+00 0.000E+00 Kr-85m GONADS 7.310E-15 2.594E-12 3.653E-12 1.570E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 8.410E-15 2.527E-12 3.560E-12 1.530E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 7.040E-15 2.379E-12 3.351E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 6.430E-15 2.346E-12 3.304E-12 1.420E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.880E-14 5.286E-12 7.446E-12 3.200E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 7.330E-15 2.395E-12 3.374E-12 1.450E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 6.640E-15 2.313E-12 3.257E-12 1.400E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 7.480E-15 2.511E-12 3.537E-12 1.520E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 2.240E-14 2.247E-11 3.164E-11 1.360E-15-1.000E+00 0.000E+00 0.000E+00 Kr-87 GONADS 4.000E-14 4.962E-12 5.026E-12 7.610E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 4.500E-14 4.740E-12 4.802E-12 7.270E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 4.040E-14 4.603E-12 4.663E-12 7.060E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 4.000E-14 4.708E-12 4.769E-12 7.220E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 6.020E-14 6.514E-12 6.598E-12 9.990E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 4.130E-14 4.473E-12 4.531E-12 6.860E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 3.910E-14 4.590E-12 4.650E-12 7.040E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 4.120E-14 4.773E-12 4.835E-12 7.320E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.370E-13 8.802E-11 8.916E-11 1.350E-14-1.000E+00 0.000E+00 0.000E+00 Kr-88 GONADS 9.900E-14 2.278E-11 2.655E-11 1.800E-15-1.000E+00 0.000E+00 0.000E+00 BREAST 1.110E-13 2.177E-11 2.537E-11 1.720E-15-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.010E-13 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.000E-13 2.190E-11 2.552E-11 1.730E-15-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.390E-13 2.886E-11 3.363E-11 2.280E-15-1.000E+00 0.000E+00 0.000E+00 THYROID 1.030E-13 2.012E-11 2.345E-11 1.590E-15-1.000E+00 0.000E+00 0.000E+00 REMAINDER 9.790E-14 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.020E-13 2.202E-11 2.567E-11 1.740E-15-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.350E-13 5.607E-11 6.534E-11 4.430E-15-1.000E+00 0.000E+00 0.000E+00 Rb-86 GONADS 4.710E-15 2.788E-12 5.187E-11 9.740E-17-1.000E+00 1.340E-09 2.150E-09 BREAST 5.340E-15 2.662E-12 4.953E-11 9.300E-17-1.000E+00 1.330E-09 2.140E-09 LUNGS 4.710E-15 2.553E-12 4.750E-11 8.920E-17-1.000E+00 3.300E-09 2.140E-09 RED MARR 4.640E-15 2.619E-12 4.873E-11 9.150E-17-1.000E+00 2.320E-09 3.720E-09 BONE SUR 7.050E-15 3.635E-12 6.764E-11 1.270E-16-1.000E+00 4.270E-09 6.860E-09 THYROID 4.840E-15 2.599E-12 4.836E-11 9.080E-17-1.000E+00 1.330E-09 2.140E-09 REMAINDER 4.520E-15 2.542E-12 4.729E-11 8.880E-17-1.000E+00 1.380E-09 2.330E-09 EFFECTIVE 4.810E-15 2.665E-12 4.958E-11 9.310E-17-1.000E+00 1.790E-09 2.530E-09 SKIN(FGR) 4.850E-14 2.210E-10 4.111E-09 7.720E-15-1.000E+00 0.000E+00 0.000E+00 Sr-89 GONADS 7.730E-17 7.155E-14 1.436E-12 2.490E-18-1.000E+00 7.950E-12 8.050E-12 BREAST 9.080E-17 7.212E-14 1.447E-12 2.510E-18-1.000E+00 7.960E-12 7.980E-12 LUNGS 7.080E-17 5.689E-14 1.142E-12 1.980E-18-1.000E+00 8.350E-08 7.970E-12 RED MARR 6.390E-17 5.345E-14 1.073E-12 1.860E-18-1.000E+00 1.070E-10 1.080E-10 BONE SUR 1.940E-16 1.560E-13 3.131E-12 5.430E-18-1.000E+00 1.590E-10 1.610E-10 THYROID 7.600E-17 6.063E-14 1.217E-12 2.110E-18-1.000E+00 7.960E-12 7.970E-12 REMAINDER 6.710E-17 5.603E-14 1.124E-12 1.950E-18-1.000E+00 3.970E-09 8.250E-09 EFFECTIVE 7.730E-17 6.523E-14 1.309E-12 2.270E-18-1.000E+00 1.120E-08 2.500E-09 SKIN(FGR) 3.690E-14 1.914E-10 3.841E-09 6.660E-15-1.000E+00 0.000E+00 0.000E+00 Sr-90 GONADS 7.780E-18 9.590E-15 2.014E-13 3.330E-19-1.000E+00 2.690E-10 5.040E-11 BREAST 9.490E-18 1.008E-14 2.116E-13 3.500E-19-1.000E+00 2.690E-10 5.040E-11 LUNGS 6.440E-18 6.307E-15 1.324E-13 2.190E-19-1.000E+00 2.860E-06 5.040E-11 RED MARR 5.440E-18 5.558E-15 1.167E-13 1.930E-19-1.000E+00 3.280E-08 6.450E-09 BONE SUR 2.280E-17 2.393E-14 5.025E-13 8.310E-19-1.000E+00 7.090E-08 1.390E-08 THYROID 7.330E-18 7.171E-15 1.506E-13 2.490E-19-1.000E+00 2.690E-10 5.040E-11 REMAINDER 6.110E-18 6.422E-15 1.348E-13 2.230E-19-1.000E+00 5.730E-09 6.700E-09 EFFECTIVE 7.530E-18 8.179E-15 1.717E-13 2.840E-19-1.000E+00 3.510E-07 3.230E-09 SKIN(FGR) 9.200E-15 4.032E-12 8.465E-11 1.400E-16-1.000E+00 0.000E+00 0.000E+00 Sr-91 GONADS 3.380E-14 2.155E-11 5.062E-11 1.026E-15-1.000E+00 5.650E-11 2.520E-10 BREAST 3.830E-14 2.059E-11 4.838E-11 9.806E-16-1.000E+00 1.740E-11 3.676E-11 LUNGS 3.370E-14 1.970E-11 4.626E-11 9.376E-16-1.000E+00 2.130E-09 1.055E-11
Numerical Applications Inc. Attachment 6 Page 120 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 RED MARR 3.310E-14 2.011E-11 4.722E-11 9.570E-16-1.000E+00 2.230E-11 5.659E-11 BONE SUR 5.200E-14 2.852E-11 6.709E-11 1.360E-15-1.000E+00 1.270E-11 2.070E-11 THYROID 3.470E-14 2.035E-11 4.782E-11 9.693E-16-1.000E+00 9.640E-12 1.968E-12 REMAINDER 3.240E-14 1.948E-11 4.573E-11 9.268E-16-1.000E+00 5.780E-10 2.557E-09 EFFECTIVE 3.450E-14 2.057E-11 4.832E-11 9.793E-16-1.000E+00 4.490E-10 8.455E-10 SKIN(FGR) 8.140E-14 1.748E-10 3.987E-10 8.080E-15-1.000E+00 0.000E+00 0.000E+00 Sr-92 GONADS 6.610E-14 1.593E-11 1.830E-11 1.300E-15-1.000E+00 1.020E-11 8.180E-11 BREAST 7.480E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 6.490E-12 1.700E-11 LUNGS 6.670E-14 1.483E-11 1.703E-11 1.210E-15-1.000E+00 1.050E-09 7.220E-12 RED MARR 6.620E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 6.980E-12 2.290E-11 BONE SUR 9.490E-14 2.010E-11 2.308E-11 1.640E-15-1.000E+00 4.360E-12 8.490E-12 THYROID 6.820E-14 1.446E-11 1.661E-11 1.180E-15-1.000E+00 3.920E-12 1.300E-12 REMAINDER 6.450E-14 1.471E-11 1.689E-11 1.200E-15-1.000E+00 2.900E-10 1.720E-09 EFFECTIVE 6.790E-14 1.532E-11 1.759E-11 1.250E-15-1.000E+00 2.180E-10 5.430E-10 SKIN(FGR) 8.560E-14 2.280E-11 2.618E-11 1.860E-15-1.000E+00 0.000E+00 0.000E+00 Y-90 GONADS 1.890E-16 1.586E-13 1.601E-12 5.750E-18-1.000E+00 5.170E-13 1.430E-14 BREAST 2.200E-16 1.578E-13 1.593E-12 5.720E-18-1.000E+00 5.170E-13 1.270E-14 LUNGS 1.770E-16 1.313E-13 1.326E-12 4.760E-18-1.000E+00 9.310E-09 1.260E-14 RED MARR 1.620E-16 1.261E-13 1.273E-12 4.570E-18-1.000E+00 1.520E-11 3.700E-13 BONE SUR 4.440E-16 3.228E-13 3.259E-12 1.170E-17-1.000E+00 1.510E-11 3.670E-13 THYROID 1.870E-16 1.385E-13 1.398E-12 5.020E-18-1.000E+00 5.170E-13 1.260E-14 REMAINDER 1.680E-16 1.291E-13 1.303E-12 4.680E-18-1.000E+00 3.870E-09 9.680E-09 EFFECTIVE 1.900E-16 1.468E-13 1.482E-12 5.320E-18-1.000E+00 2.280E-09 2.910E-09 SKIN(FGR) 6.240E-14 2.897E-10 2.924E-09 1.050E-14-1.000E+00 0.000E+00 0.000E+00 Y-91 GONADS 2.560E-16 1.756E-13 3.546E-12 6.110E-18-1.000E+00 8.200E-12 3.540E-12 BREAST 2.930E-16 1.713E-13 3.459E-12 5.960E-18-1.000E+00 8.920E-12 5.540E-13 LUNGS 2.500E-16 1.526E-13 3.082E-12 5.310E-18-1.000E+00 9.870E-08 2.020E-13 RED MARR 2.410E-16 1.521E-13 3.070E-12 5.290E-18-1.000E+00 3.190E-10 6.590E-12 BONE SUR 4.560E-16 2.903E-13 5.862E-12 1.010E-17-1.000E+00 3.180E-10 6.130E-12 THYROID 2.600E-16 1.564E-13 3.157E-12 5.440E-18-1.000E+00 8.500E-12 1.290E-13 REMAINDER 2.390E-16 1.509E-13 3.047E-12 5.250E-18-1.000E+00 4.200E-09 8.570E-09 EFFECTIVE 2.600E-16 1.650E-13 3.332E-12 5.740E-18-1.000E+00 1.320E-08 2.570E-09 SKIN(FGR) 3.850E-14 1.989E-10 4.016E-09 6.920E-15-1.000E+00 0.000E+00 0.000E+00 Y-92 GONADS 1.270E-14 3.855E-12 4.872E-12 2.650E-16-1.000E+00 2.610E-12 1.960E-11 BREAST 1.440E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 1.500E-12 3.550E-12 LUNGS 1.270E-14 3.535E-12 4.468E-12 2.430E-16-1.000E+00 1.240E-09 1.390E-12 RED MARR 1.250E-14 3.608E-12 4.560E-12 2.480E-16-1.000E+00 2.070E-12 4.910E-12 BONE SUR 1.950E-14 5.091E-12 6.435E-12 3.500E-16-1.000E+00 1.510E-12 1.750E-12 THYROID 1.300E-14 3.579E-12 4.523E-12 2.460E-16-1.000E+00 1.050E-12 1.770E-13 REMAINDER 1.220E-14 3.506E-12 4.431E-12 2.410E-16-1.000E+00 2.030E-10 1.700E-09 EFFECTIVE 1.300E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 2.110E-10 5.150E-10 SKIN(FGR) 1.140E-13 2.022E-10 2.556E-10 1.390E-14-1.000E+00 0.000E+00 0.000E+00 Y-93 GONADS 4.670E-15 2.108E-12 4.989E-12 9.510E-17-1.000E+00 5.310E-12 2.200E-11 BREAST 5.300E-15 2.026E-12 4.794E-12 9.140E-17-1.000E+00 1.740E-12 3.130E-12 LUNGS 4.680E-15 1.937E-12 4.585E-12 8.740E-17-1.000E+00 2.520E-09 8.670E-13 RED MARR 4.580E-15 1.972E-12 4.669E-12 8.900E-17-1.000E+00 4.040E-12 4.930E-12 BONE SUR 7.580E-15 2.948E-12 6.977E-12 1.330E-16-1.000E+00 3.140E-12 1.730E-12 THYROID 4.790E-15 1.908E-12 4.516E-12 8.610E-17-1.000E+00 9.260E-13 1.260E-13 REMAINDER 4.510E-15 1.919E-12 4.543E-12 8.660E-17-1.000E+00 9.250E-10 4.090E-09 EFFECTIVE 4.800E-15 2.021E-12 4.784E-12 9.120E-17-1.000E+00 5.820E-10 1.230E-09 SKIN(FGR) 8.500E-14 2.726E-10 6.452E-10 1.230E-14-1.000E+00 0.000E+00 0.000E+00 Zr-95 GONADS 3.530E-14 2.182E-11 4.421E-10 7.590E-16-1.000E+00 1.880E-09 8.160E-10 BREAST 4.010E-14 2.084E-11 4.223E-10 7.250E-16-1.000E+00 1.910E-09 1.050E-10 LUNGS 3.510E-14 1.989E-11 4.030E-10 6.920E-16-1.000E+00 2.170E-09 2.340E-11 RED MARR 3.430E-14 2.030E-11 4.112E-10 7.060E-16-1.000E+00 1.300E-08 2.140E-10 BONE SUR 5.620E-14 2.875E-11 5.824E-10 1.000E-15-1.000E+00 1.030E-07 4.860E-10 THYROID 3.610E-14 2.076E-11 4.205E-10 7.220E-16-1.000E+00 1.440E-09 8.270E-12 REMAINDER 3.360E-14 1.963E-11 3.978E-10 6.830E-16-1.000E+00 2.280E-09 2.530E-09 EFFECTIVE 3.600E-14 2.078E-11 4.211E-10 7.230E-16-1.000E+00 6.390E-09 1.020E-09 SKIN(FGR) 4.500E-14 2.561E-11 5.190E-10 8.910E-16-1.000E+00 0.000E+00 0.000E+00 Zr-97 GONADS 8.800E-15 2.179E-11 7.799E-11 9.253E-16-1.000E+00 1.840E-10 6.228E-10 BREAST 9.990E-15 2.083E-11 7.455E-11 8.846E-16-1.000E+00 4.700E-11 8.137E-11 LUNGS 8.810E-15 1.992E-11 7.127E-11 8.456E-16-1.000E+00 4.100E-09 1.770E-11 RED MARR 8.640E-15 2.034E-11 7.279E-11 8.634E-16-1.000E+00 6.370E-11 1.302E-10 BONE SUR 1.380E-14 2.881E-11 1.031E-10 1.224E-15-1.000E+00 3.500E-11 4.558E-11 THYROID 9.030E-15 2.061E-11 7.377E-11 8.755E-16-1.000E+00 2.310E-11 2.671E-12
Numerical Applications Inc. Attachment 6 Page 121 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 REMAINDER 8.480E-15 1.966E-11 7.035E-11 8.345E-16-1.000E+00 2.040E-09 6.990E-09 EFFECTIVE 9.020E-15 2.078E-11 7.438E-11 8.824E-16-1.000E+00 1.170E-09 2.283E-09 SKIN(FGR) 5.550E-14 2.281E-10 8.148E-10 9.587E-15-1.000E+00 0.000E+00 0.000E+00 Nb-95 GONADS 3.660E-14 2.253E-11 4.435E-10 7.850E-16-1.000E+00 4.320E-10 8.050E-10 BREAST 4.160E-14 2.150E-11 4.231E-10 7.490E-16-1.000E+00 4.070E-10 1.070E-10 LUNGS 3.650E-14 2.055E-11 4.045E-10 7.160E-16-1.000E+00 8.320E-09 2.740E-11 RED MARR 3.560E-14 2.101E-11 4.135E-10 7.320E-16-1.000E+00 4.420E-10 1.990E-10 BONE SUR 5.790E-14 2.957E-11 5.819E-10 1.030E-15-1.000E+00 5.130E-10 2.940E-10 THYROID 3.750E-14 2.144E-11 4.220E-10 7.470E-16-1.000E+00 3.580E-10 1.180E-11 REMAINDER 3.490E-14 2.032E-11 4.000E-10 7.080E-16-1.000E+00 1.070E-09 1.470E-09 EFFECTIVE 3.740E-14 2.147E-11 4.226E-10 7.480E-16-1.000E+00 1.570E-09 6.950E-10 SKIN(FGR) 4.300E-14 2.598E-11 5.112E-10 9.050E-16-1.000E+00 0.000E+00 0.000E+00 Mo-99 GONADS 7.130E-15 4.282E-12 4.403E-11 1.550E-16-1.000E+00 9.510E-11 2.180E-10 BREAST 8.130E-15 4.116E-12 4.233E-11 1.490E-16-1.000E+00 2.750E-11 3.430E-11 LUNGS 7.060E-15 3.867E-12 3.977E-11 1.400E-16-1.000E+00 4.290E-09 1.510E-11 RED MARR 6.820E-15 3.923E-12 4.034E-11 1.420E-16-1.000E+00 5.240E-11 8.320E-11 BONE SUR 1.240E-14 6.105E-12 6.278E-11 2.210E-16-1.000E+00 4.130E-11 6.320E-11 THYROID 7.270E-15 4.033E-12 4.147E-11 1.460E-16-1.000E+00 1.520E-11 1.030E-11 REMAINDER 6.740E-15 3.812E-12 3.920E-11 1.380E-16-1.000E+00 1.740E-09 4.280E-09 EFFECTIVE 7.280E-15 4.061E-12 4.176E-11 1.470E-16-1.000E+00 1.070E-09 1.360E-09 SKIN(FGR) 3.140E-14 1.039E-10 1.068E-09 3.760E-15-1.000E+00 0.000E+00 0.000E+00 Tc-99m GONADS 5.750E-15 2.334E-12 3.877E-12 1.240E-16-1.000E+00 2.770E-12 9.750E-12 BREAST 6.650E-15 2.258E-12 3.752E-12 1.200E-16-1.000E+00 2.150E-12 3.570E-12 LUNGS 5.490E-15 2.127E-12 3.533E-12 1.130E-16-1.000E+00 2.280E-11 3.140E-12 RED MARR 4.910E-15 2.070E-12 3.439E-12 1.100E-16-1.000E+00 3.360E-12 6.290E-12 BONE SUR 1.630E-14 5.383E-12 8.942E-12 2.860E-16-1.000E+00 2.620E-12 4.060E-12 THYROID 5.750E-15 2.145E-12 3.564E-12 1.140E-16-1.000E+00 5.010E-11 8.460E-11 REMAINDER 5.150E-15 2.070E-12 3.439E-12 1.100E-16-1.000E+00 1.020E-11 3.340E-11 EFFECTIVE 5.890E-15 2.277E-12 3.783E-12 1.210E-16-1.000E+00 8.800E-12 1.680E-11 SKIN(FGR) 7.140E-15 2.710E-12 4.502E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 Ru-103 GONADS 2.190E-14 1.404E-11 2.783E-10 4.892E-16-1.000E+00 3.070E-10 5.720E-10 BREAST 2.510E-14 1.350E-11 2.677E-10 4.705E-16-1.000E+00 3.110E-10 1.200E-10 LUNGS 2.180E-14 1.273E-11 2.522E-10 4.432E-16-1.000E+00 1.560E-08 7.310E-11 RED MARR 2.100E-14 1.287E-11 2.551E-10 4.483E-16-1.000E+00 3.190E-10 1.660E-10 BONE SUR 3.890E-14 1.958E-11 3.882E-10 6.823E-16-1.000E+00 2.370E-10 9.631E-11 THYROID 2.240E-14 1.331E-11 2.639E-10 4.638E-16-1.000E+00 2.570E-10 6.250E-11 REMAINDER 2.080E-14 1.248E-11 2.472E-10 4.346E-16-1.000E+00 1.250E-09 2.110E-09 EFFECTIVE 2.250E-14 1.332E-11 2.641E-10 4.642E-16-1.000E+00 2.420E-09 8.271E-10 SKIN(FGR) 2.770E-14 1.785E-11 3.543E-10 6.229E-16-1.000E+00 0.000E+00 0.000E+00 Ru-105 GONADS 3.720E-14 1.327E-11 1.861E-11 8.070E-16-1.000E+00 1.590E-11 9.670E-11 BREAST 4.240E-14 1.271E-11 1.783E-11 7.730E-16-1.000E+00 6.610E-12 1.590E-11 LUNGS 3.700E-14 1.210E-11 1.697E-11 7.360E-16-1.000E+00 5.730E-10 6.210E-12 RED MARR 3.590E-14 1.230E-11 1.725E-11 7.480E-16-1.000E+00 7.700E-12 2.350E-11 BONE SUR 6.280E-14 1.809E-11 2.537E-11 1.100E-15-1.000E+00 4.620E-12 8.890E-12 THYROID 3.800E-14 1.260E-11 1.766E-11 7.660E-16-1.000E+00 4.150E-12 1.820E-12 REMAINDER 3.540E-14 1.189E-11 1.667E-11 7.230E-16-1.000E+00 1.610E-10 8.540E-10 EFFECTIVE 3.810E-14 1.265E-11 1.773E-11 7.690E-16-1.000E+00 1.230E-10 2.870E-10 SKIN(FGR) 6.730E-14 7.368E-11 1.033E-10 4.480E-15-1.000E+00 0.000E+00 0.000E+00 Ru-106 GONADS 0.000E+00 6.411E-12 1.340E-10 2.230E-16-1.000E+00 1.300E-09 1.640E-09 BREAST 0.000E+00 6.152E-12 1.286E-10 2.140E-16-1.000E+00 1.780E-09 1.440E-09 LUNGS 0.000E+00 5.836E-12 1.220E-10 2.030E-16-1.000E+00 1.040E-06 1.420E-09 RED MARR 0.000E+00 5.893E-12 1.232E-10 2.050E-16-1.000E+00 1.760E-09 1.460E-09 BONE SUR 0.000E+00 8.883E-12 1.856E-10 3.090E-16-1.000E+00 1.610E-09 1.430E-09 THYROID 0.000E+00 6.066E-12 1.268E-10 2.110E-16-1.000E+00 1.720E-09 1.410E-09 REMAINDER 0.000E+00 5.721E-12 1.196E-10 1.990E-16-1.000E+00 1.200E-08 2.110E-08 EFFECTIVE 0.000E+00 6.095E-12 1.274E-10 2.120E-16-1.000E+00 1.290E-07 7.400E-09 SKIN(FGR) 0.000E+00 4.082E-10 8.531E-09 1.420E-14-1.000E+00 0.000E+00 0.000E+00 Rh-105 GONADS 3.640E-15 2.127E-12 1.411E-11 7.980E-17-1.000E+00 2.110E-11 5.800E-11 BREAST 4.160E-15 2.063E-12 1.369E-11 7.740E-17-1.000E+00 5.610E-12 8.970E-12 LUNGS 3.570E-15 1.935E-12 1.284E-11 7.260E-17-1.000E+00 9.580E-10 3.860E-12 RED MARR 3.380E-15 1.946E-12 1.291E-11 7.300E-17-1.000E+00 7.770E-12 1.470E-11 BONE SUR 7.530E-15 3.332E-12 2.210E-11 1.250E-16-1.000E+00 4.460E-12 6.750E-12 THYROID 3.680E-15 1.983E-12 1.316E-11 7.440E-17-1.000E+00 2.880E-12 2.910E-12 REMAINDER 3.390E-15 1.885E-12 1.250E-11 7.070E-17-1.000E+00 4.530E-10 1.270E-09 EFFECTIVE 3.720E-15 2.031E-12 1.347E-11 7.620E-17-1.000E+00 2.580E-10 3.990E-10 SKIN(FGR) 1.070E-14 4.691E-12 3.112E-11 1.760E-16-1.000E+00 0.000E+00 0.000E+00
Numerical Applications Inc. Attachment 6 Page 122 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Sb-127 GONADS 3.260E-14 1.985E-11 2.441E-10 7.100E-16-1.000E+00 2.520E-10 6.140E-10 BREAST 3.720E-14 1.904E-11 2.341E-10 6.810E-16-1.000E+00 9.120E-11 7.600E-11 LUNGS 3.240E-14 1.809E-11 2.224E-10 6.470E-16-1.000E+00 6.940E-09 1.570E-11 RED MARR 3.140E-14 1.834E-11 2.255E-10 6.560E-16-1.000E+00 1.610E-10 1.330E-10 BONE SUR 5.520E-14 2.720E-11 3.345E-10 9.730E-16-1.000E+00 1.340E-10 5.240E-11 THYROID 3.330E-14 1.884E-11 2.317E-10 6.740E-16-1.000E+00 6.150E-11 4.640E-12 REMAINDER 3.090E-14 1.775E-11 2.183E-10 6.350E-16-1.000E+00 2.330E-09 5.870E-09 EFFECTIVE 3.330E-14 1.890E-11 2.324E-10 6.760E-16-1.000E+00 1.630E-09 1.950E-09 SKIN(FGR) 5.580E-14 7.967E-11 9.799E-10 2.850E-15-1.000E+00 0.000E+00 0.000E+00 Sb-129 GONADS 6.970E-14 2.336E-11 3.231E-11 1.440E-15-1.000E+00 2.150E-11 1.510E-10 BREAST 7.910E-14 2.222E-11 3.074E-11 1.370E-15-1.000E+00 1.280E-11 2.560E-11 LUNGS 6.980E-14 2.141E-11 2.962E-11 1.320E-15-1.000E+00 8.980E-10 9.390E-12 RED MARR 6.860E-14 2.190E-11 3.029E-11 1.350E-15-1.000E+00 1.700E-11 3.670E-11 BONE SUR 1.070E-13 3.033E-11 4.196E-11 1.870E-15-1.000E+00 1.460E-11 1.340E-11 THYROID 7.160E-14 2.174E-11 3.007E-11 1.340E-15-1.000E+00 9.720E-12 1.470E-12 REMAINDER 6.710E-14 2.125E-11 2.939E-11 1.310E-15-1.000E+00 1.870E-10 1.450E-09 EFFECTIVE 7.140E-14 2.238E-11 3.096E-11 1.380E-15-1.000E+00 1.740E-10 4.840E-10 SKIN(FGR) 1.050E-13 8.273E-11 1.144E-10 5.100E-15-1.000E+00 0.000E+00 0.000E+00 Te-127 GONADS 2.370E-16 1.191E-13 2.661E-13 5.480E-18-1.000E+00 2.020E-12 4.020E-12 BREAST 2.730E-16 1.158E-13 2.588E-13 5.330E-18-1.000E+00 1.880E-12 3.000E-12 LUNGS 2.320E-16 1.060E-13 2.370E-13 4.880E-18-1.000E+00 4.270E-10 2.890E-12 RED MARR 2.210E-16 1.058E-13 2.365E-13 4.870E-18-1.000E+00 4.090E-12 6.570E-12 BONE SUR 4.650E-16 1.862E-13 4.162E-13 8.570E-18-1.000E+00 4.090E-12 6.460E-12 THYROID 2.400E-16 1.106E-13 2.472E-13 5.090E-18-1.000E+00 1.840E-12 2.860E-12 REMAINDER 2.210E-16 1.036E-13 2.316E-13 4.770E-18-1.000E+00 1.110E-10 6.130E-10 EFFECTIVE 2.420E-16 1.125E-13 2.515E-13 5.180E-18-1.000E+00 8.600E-11 1.870E-10 SKIN(FGR) 1.140E-14 1.173E-11 2.622E-11 5.400E-16-1.000E+00 0.000E+00 0.000E+00 Te-127m GONADS 1.900E-16 4.689E-13 9.642E-12 1.630E-17-1.000E+00 1.100E-10 1.250E-10 BREAST 2.690E-16 5.150E-13 1.059E-11 1.790E-17-1.000E+00 1.100E-10 9.740E-11 LUNGS 7.620E-17 1.602E-13 3.295E-12 5.570E-18-1.000E+00 3.340E-08 9.620E-11 RED MARR 6.430E-17 1.249E-13 2.567E-12 4.340E-18-1.000E+00 5.360E-09 5.430E-09 BONE SUR 3.940E-16 9.005E-13 1.852E-11 3.130E-17-1.000E+00 2.040E-08 2.070E-08 THYROID 1.500E-16 2.779E-13 5.714E-12 9.660E-18-1.000E+00 9.660E-11 9.430E-11 REMAINDER 8.640E-17 1.999E-13 4.111E-12 6.950E-18-1.000E+00 1.660E-09 2.980E-09 EFFECTIVE 1.470E-16 3.251E-13 6.684E-12 1.130E-17-1.000E+00 5.810E-09 2.230E-09 SKIN(FGR) 8.490E-16 1.496E-12 3.076E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 Te-129 GONADS 2.710E-15 3.889E-13 3.922E-13 6.510E-17-1.000E+00 1.750E-12 1.590E-12 BREAST 3.120E-15 3.800E-13 3.832E-13 6.360E-17-1.000E+00 1.680E-12 6.050E-13 LUNGS 2.640E-15 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.330E-10 4.910E-13 RED MARR 2.540E-15 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.970E-12 7.640E-13 BONE SUR 4.880E-15 5.753E-13 5.802E-13 9.630E-17-1.000E+00 2.030E-12 5.400E-13 THYROID 2.740E-15 3.525E-13 3.555E-13 5.900E-17-1.000E+00 1.630E-12 3.360E-13 REMAINDER 2.520E-15 3.262E-13 3.289E-13 5.460E-17-1.000E+00 2.400E-11 1.790E-10 EFFECTIVE 2.750E-15 3.590E-13 3.621E-13 6.010E-17-1.000E+00 2.420E-11 5.450E-11 SKIN(FGR) 3.570E-14 3.429E-11 3.458E-11 5.740E-15-1.000E+00 0.000E+00 0.000E+00 Te-129m GONADS 1.560E-15 2.206E-12 4.799E-11 8.561E-17-1.000E+00 1.780E-10 2.420E-10 BREAST 1.810E-15 2.181E-12 4.739E-11 8.454E-17-1.000E+00 1.690E-10 1.664E-10 LUNGS 1.460E-15 1.741E-12 3.815E-11 6.808E-17-1.000E+00 4.030E-08 1.593E-10 RED MARR 1.420E-15 1.729E-12 3.793E-11 6.768E-17-1.000E+00 3.100E-09 3.500E-09 BONE SUR 2.600E-15 3.287E-12 7.147E-11 1.275E-16-1.000E+00 7.050E-09 7.990E-09 THYROID 1.560E-15 1.923E-12 4.201E-11 7.495E-17-1.000E+00 1.560E-10 1.572E-10 REMAINDER 1.410E-15 1.746E-12 3.822E-11 6.819E-17-1.000E+00 3.270E-09 7.196E-09 EFFECTIVE 1.550E-15 1.974E-12 4.308E-11 7.686E-17-1.000E+00 6.470E-09 2.925E-09 SKIN(FGR) 1.490E-14 1.501E-10 3.360E-09 6.001E-15-1.000E+00 0.000E+00 0.000E+00 Te-131m GONADS 6.850E-14 4.020E-11 2.343E-10 1.535E-15-1.000E+00 2.340E-10 7.415E-10 BREAST 7.780E-14 3.853E-11 2.246E-10 1.472E-15-1.000E+00 9.250E-11 1.361E-10 LUNGS 6.830E-14 3.657E-11 2.131E-10 1.397E-15-1.000E+00 2.230E-09 6.335E-11 RED MARR 6.680E-14 3.736E-11 2.178E-10 1.427E-15-1.000E+00 1.410E-10 2.435E-10 BONE SUR 1.090E-13 5.467E-11 3.189E-10 2.090E-15-1.000E+00 2.270E-10 3.248E-10 THYROID 7.020E-14 3.741E-11 2.181E-10 1.429E-15-1.000E+00 3.610E-08 4.383E-08 REMAINDER 6.550E-14 3.626E-11 2.113E-10 1.385E-15-1.000E+00 9.460E-10 3.153E-09 EFFECTIVE 7.010E-14 3.825E-11 2.229E-10 1.461E-15-1.000E+00 1.730E-09 2.514E-09 SKIN(FGR) 8.850E-14 1.033E-10 6.188E-10 4.056E-15-1.000E+00 0.000E+00 0.000E+00 Te-132 GONADS 1.020E-14 6.812E-12 7.706E-11 2.450E-16-1.000E+00 4.150E-10 5.410E-10 BREAST 1.180E-14 6.756E-12 7.643E-11 2.430E-16-1.000E+00 3.630E-10 3.500E-10
Numerical Applications Inc. Attachment 6 Page 123 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 LUNGS 9.650E-15 5.727E-12 6.479E-11 2.060E-16-1.000E+00 1.670E-09 3.300E-10 RED MARR 8.950E-15 5.588E-12 6.322E-11 2.010E-16-1.000E+00 4.270E-10 4.440E-10 BONE SUR 2.420E-14 1.273E-11 1.441E-10 4.580E-16-1.000E+00 7.120E-10 8.300E-10 THYROID 1.020E-14 5.978E-12 6.762E-11 2.150E-16-1.000E+00 6.280E-08 5.950E-08 REMAINDER 9.160E-15 5.644E-12 6.385E-11 2.030E-16-1.000E+00 7.890E-10 1.490E-09 EFFECTIVE 1.030E-14 6.339E-12 7.171E-11 2.280E-16-1.000E+00 2.550E-09 2.540E-09 SKIN(FGR) 1.390E-14 8.313E-12 9.405E-11 2.990E-16-1.000E+00 0.000E+00 0.000E+00 I-131 GONADS 1.780E-14 1.119E-11 1.789E-10 3.940E-16-1.000E+00 2.530E-11 4.070E-11 BREAST 2.040E-14 1.082E-11 1.730E-10 3.810E-16-1.000E+00 7.880E-11 1.210E-10 LUNGS 1.760E-14 1.016E-11 1.626E-10 3.580E-16-1.000E+00 6.570E-10 1.020E-10 RED MARR 1.680E-14 1.022E-11 1.635E-10 3.600E-16-1.000E+00 6.260E-11 9.440E-11 BONE SUR 3.450E-14 1.675E-11 2.679E-10 5.900E-16-1.000E+00 5.730E-11 8.720E-11 THYROID 1.810E-14 1.053E-11 1.685E-10 3.710E-16-1.000E+00 2.920E-07 4.760E-07 REMAINDER 1.670E-14 9.908E-12 1.585E-10 3.490E-16-1.000E+00 8.030E-11 1.570E-10 EFFECTIVE 1.820E-14 1.067E-11 1.707E-10 3.760E-16-1.000E+00 8.890E-09 1.440E-08 SKIN(FGR) 2.980E-14 1.825E-11 2.920E-10 6.430E-16-1.000E+00 0.000E+00 0.000E+00 I-132 GONADS 1.090E-13 2.523E-11 2.771E-11 2.320E-15-1.000E+00 9.950E-12 2.330E-11 BREAST 1.240E-13 2.414E-11 2.652E-11 2.220E-15-1.000E+00 1.410E-11 2.520E-11 LUNGS 1.090E-13 2.305E-11 2.532E-11 2.120E-15-1.000E+00 2.710E-10 2.640E-11 RED MARR 1.070E-13 2.360E-11 2.592E-11 2.170E-15-1.000E+00 1.400E-11 2.460E-11 BONE SUR 1.730E-13 3.327E-11 3.655E-11 3.060E-15-1.000E+00 1.240E-11 2.190E-11 THYROID 1.120E-13 2.381E-11 2.616E-11 2.190E-15-1.000E+00 1.740E-09 3.870E-09 REMAINDER 1.050E-13 2.283E-11 2.509E-11 2.100E-15-1.000E+00 3.780E-11 1.650E-10 EFFECTIVE 1.120E-13 2.403E-11 2.640E-11 2.210E-15-1.000E+00 1.030E-10 1.820E-10 SKIN(FGR) 1.580E-13 8.199E-11 9.007E-11 7.540E-15-1.000E+00 0.000E+00 0.000E+00 I-133 GONADS 2.870E-14 1.585E-11 6.748E-11 6.270E-16-1.000E+00 1.950E-11 3.630E-11 BREAST 3.280E-14 1.519E-11 6.468E-11 6.010E-16-1.000E+00 2.940E-11 4.680E-11 LUNGS 2.860E-14 1.446E-11 6.156E-11 5.720E-16-1.000E+00 8.200E-10 4.530E-11 RED MARR 2.770E-14 1.466E-11 6.242E-11 5.800E-16-1.000E+00 2.720E-11 4.300E-11 BONE SUR 4.870E-14 2.161E-11 9.202E-11 8.550E-16-1.000E+00 2.520E-11 4.070E-11 THYROID 2.930E-14 1.502E-11 6.393E-11 5.940E-16-1.000E+00 4.860E-08 9.100E-08 REMAINDER 2.730E-14 1.418E-11 6.038E-11 5.610E-16-1.000E+00 5.000E-11 1.550E-10 EFFECTIVE 2.940E-14 1.509E-11 6.425E-11 5.970E-16-1.000E+00 1.580E-09 2.800E-09 SKIN(FGR) 5.830E-14 1.150E-10 4.897E-10 4.550E-15-1.000E+00 0.000E+00 0.000E+00 I-134 GONADS 1.270E-13 1.200E-11 1.202E-11 2.640E-15-1.000E+00 4.250E-12 1.100E-11 BREAST 1.440E-13 1.145E-11 1.147E-11 2.520E-15-1.000E+00 6.170E-12 1.170E-11 LUNGS 1.270E-13 1.100E-11 1.102E-11 2.420E-15-1.000E+00 1.430E-10 1.260E-11 RED MARR 1.250E-13 1.127E-11 1.129E-11 2.480E-15-1.000E+00 6.080E-12 1.090E-11 BONE SUR 1.960E-13 1.568E-11 1.571E-11 3.450E-15-1.000E+00 5.310E-12 9.320E-12 THYROID 1.300E-13 1.127E-11 1.129E-11 2.480E-15-1.000E+00 2.880E-10 6.210E-10 REMAINDER 1.220E-13 1.091E-11 1.093E-11 2.400E-15-1.000E+00 2.270E-11 1.340E-10 EFFECTIVE 1.300E-13 1.150E-11 1.152E-11 2.530E-15-1.000E+00 3.550E-11 6.660E-11 SKIN(FGR) 1.870E-13 4.477E-11 4.485E-11 9.850E-15-1.000E+00 0.000E+00 0.000E+00 I-135 GONADS 7.770E-14 3.113E-11 5.489E-11 1.599E-15-1.000E+00 1.700E-11 3.610E-11 BREAST 8.790E-14 2.971E-11 5.240E-11 1.526E-15-1.000E+00 2.340E-11 3.850E-11 LUNGS 7.840E-14 2.886E-11 5.089E-11 1.482E-15-1.000E+00 4.410E-10 3.750E-11 RED MARR 7.760E-14 2.965E-11 5.228E-11 1.523E-15-1.000E+00 2.240E-11 3.650E-11 BONE SUR 1.130E-13 3.983E-11 7.024E-11 2.046E-15-1.000E+00 2.010E-11 3.360E-11 THYROID 8.010E-14 2.852E-11 5.030E-11 1.465E-15-1.000E+00 8.460E-09 1.790E-08 REMAINDER 7.570E-14 2.883E-11 5.084E-11 1.481E-15-1.000E+00 4.700E-11 1.540E-10 EFFECTIVE 7.980E-14 2.989E-11 5.271E-11 1.535E-15-1.000E+00 3.320E-10 6.080E-10 SKIN(FGR) 1.110E-13 9.826E-11 1.733E-10 5.047E-15-1.000E+00 0.000E+00 0.000E+00 Xe-133 GONADS 1.610E-15 1.465E-12 2.052E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 BREAST 1.960E-15 1.505E-12 2.107E-11 5.340E-17-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.320E-15 1.045E-12 1.464E-11 3.710E-17-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.070E-15 8.791E-13 1.231E-11 3.120E-17-1.000E+00 0.000E+00 0.000E+00 BONE SUR 5.130E-15 4.254E-12 5.958E-11 1.510E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 1.510E-15 1.181E-12 1.653E-11 4.190E-17-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.240E-15 1.042E-12 1.460E-11 3.700E-17-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.560E-15 1.299E-12 1.819E-11 4.610E-17-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 4.970E-15 1.953E-12 2.734E-11 6.930E-17-1.000E+00 0.000E+00 0.000E+00 Xe-135 GONADS 1.170E-14 5.455E-12 1.194E-11 2.530E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 1.330E-14 5.325E-12 1.166E-11 2.470E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.130E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.070E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 2.570E-14 9.120E-12 1.997E-11 4.230E-16-1.000E+00 0.000E+00 0.000E+00
Numerical Applications Inc. Attachment 6 Page 124 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 THYROID 1.180E-14 5.023E-12 1.100E-11 2.330E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.080E-14 4.829E-12 1.058E-11 2.240E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.190E-14 5.217E-12 1.142E-11 2.420E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 3.120E-14 4.506E-11 9.867E-11 2.090E-15-1.000E+00 0.000E+00 0.000E+00 Cs-134 GONADS 7.400E-14 4.607E-11 9.646E-10 1.600E-15-1.000E+00 1.300E-08 2.060E-08 BREAST 8.430E-14 4.406E-11 9.224E-10 1.530E-15-1.000E+00 1.080E-08 1.720E-08 LUNGS 7.370E-14 4.204E-11 8.802E-10 1.460E-15-1.000E+00 1.180E-08 1.760E-08 RED MARR 7.190E-14 4.262E-11 8.922E-10 1.480E-15-1.000E+00 1.180E-08 1.870E-08 BONE SUR 1.200E-13 6.105E-11 1.278E-09 2.120E-15-1.000E+00 1.100E-08 1.740E-08 THYROID 7.570E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.110E-08 1.760E-08 REMAINDER 7.060E-14 4.147E-11 8.681E-10 1.440E-15-1.000E+00 1.390E-08 2.210E-08 EFFECTIVE 7.570E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.250E-08 1.980E-08 SKIN(FGR) 9.450E-14 6.249E-11 1.308E-09 2.170E-15-1.000E+00 0.000E+00 0.000E+00 Cs-136 GONADS 1.040E-13 6.223E-11 1.102E-09 2.180E-15-1.000E+00 1.880E-09 3.040E-09 BREAST 1.180E-13 5.966E-11 1.056E-09 2.090E-15-1.000E+00 1.670E-09 2.650E-09 LUNGS 1.040E-13 5.710E-11 1.011E-09 2.000E-15-1.000E+00 2.320E-09 2.620E-09 RED MARR 1.010E-13 5.824E-11 1.031E-09 2.040E-15-1.000E+00 1.860E-09 2.950E-09 BONE SUR 1.660E-13 8.422E-11 1.491E-09 2.950E-15-1.000E+00 1.700E-09 2.710E-09 THYROID 1.070E-13 5.852E-11 1.036E-09 2.050E-15-1.000E+00 1.730E-09 2.740E-09 REMAINDER 9.950E-14 5.652E-11 1.001E-09 1.980E-15-1.000E+00 2.190E-09 3.520E-09 EFFECTIVE 1.060E-13 5.966E-11 1.056E-09 2.090E-15-1.000E+00 1.980E-09 3.040E-09 SKIN(FGR) 1.250E-13 7.251E-11 1.284E-09 2.540E-15-1.000E+00 0.000E+00 0.000E+00 Cs-137 GONADS 7.960E-18 1.669E-11 3.530E-10 5.840E-16-1.000E+00 8.760E-09 1.390E-08 BREAST 9.670E-18 1.596E-11 3.376E-10 5.585E-16-1.000E+00 7.840E-09 1.240E-08 LUNGS 6.680E-18 1.517E-11 3.209E-10 5.309E-16-1.000E+00 8.820E-09 1.270E-08 RED MARR 5.700E-18 1.542E-11 3.260E-10 5.394E-16-1.000E+00 8.300E-09 1.320E-08 BONE SUR 2.290E-17 2.238E-11 4.734E-10 7.832E-16-1.000E+00 7.940E-09 1.260E-08 THYROID 7.550E-18 1.588E-11 3.358E-10 5.556E-16-1.000E+00 7.930E-09 1.260E-08 REMAINDER 6.340E-18 1.490E-11 3.152E-10 5.215E-16-1.000E+00 9.120E-09 1.450E-08 EFFECTIVE 7.740E-18 1.585E-11 3.353E-10 5.546E-16-1.000E+00 8.630E-09 1.350E-08 SKIN(FGR) 8.630E-15 5.253E-11 1.110E-09 1.836E-15-1.000E+00 0.000E+00 0.000E+00 Ba-139 GONADS 2.130E-15 3.368E-13 3.429E-13 4.790E-17-1.000E+00 2.560E-12 1.560E-12 BREAST 2.450E-15 3.297E-13 3.357E-13 4.690E-17-1.000E+00 2.460E-12 5.170E-13 LUNGS 2.030E-15 3.002E-13 3.057E-13 4.270E-17-1.000E+00 2.530E-10 3.890E-13 RED MARR 1.870E-15 2.932E-13 2.985E-13 4.170E-17-1.000E+00 3.410E-12 8.590E-13 BONE SUR 5.290E-15 6.841E-13 6.965E-13 9.730E-17-1.000E+00 2.490E-12 4.380E-13 THYROID 2.130E-15 3.044E-13 3.100E-13 4.330E-17-1.000E+00 2.400E-12 2.660E-13 REMAINDER 1.920E-15 2.932E-13 2.985E-13 4.170E-17-1.000E+00 4.820E-11 3.570E-10 EFFECTIVE 2.170E-15 3.227E-13 3.286E-13 4.590E-17-1.000E+00 4.640E-11 1.080E-10 SKIN(FGR) 6.160E-14 7.241E-11 7.373E-11 1.030E-14-1.000E+00 0.000E+00 0.000E+00 Ba-140 GONADS 8.410E-15 5.451E-12 9.607E-11 1.910E-16-1.000E+00 4.300E-10 9.960E-10 BREAST 9.640E-15 5.280E-12 9.305E-11 1.850E-16-1.000E+00 2.870E-10 1.590E-10 LUNGS 8.270E-15 4.852E-12 8.550E-11 1.700E-16-1.000E+00 1.660E-09 6.630E-11 RED MARR 7.930E-15 4.880E-12 8.601E-11 1.710E-16-1.000E+00 1.290E-09 4.390E-10 BONE SUR 1.550E-14 8.020E-12 1.413E-10 2.810E-16-1.000E+00 2.410E-09 5.530E-10 THYROID 8.530E-15 5.109E-12 9.003E-11 1.790E-16-1.000E+00 2.560E-10 5.250E-11 REMAINDER 7.890E-15 4.766E-12 8.399E-11 1.670E-16-1.000E+00 1.410E-09 7.370E-09 EFFECTIVE 8.580E-15 5.137E-12 9.053E-11 1.800E-16-1.000E+00 1.010E-09 2.560E-09 SKIN(FGR) 2.520E-14 5.565E-11 9.808E-10 1.950E-15-1.000E+00 0.000E+00 0.000E+00 La-140 GONADS 1.140E-13 6.027E-11 4.425E-10 2.240E-15-1.000E+00 4.540E-10 1.340E-09 BREAST 1.290E-13 5.758E-11 4.228E-10 2.140E-15-1.000E+00 1.450E-10 1.800E-10 LUNGS 1.150E-13 5.596E-11 4.109E-10 2.080E-15-1.000E+00 4.210E-09 4.010E-11 RED MARR 1.140E-13 5.731E-11 4.208E-10 2.130E-15-1.000E+00 2.140E-10 2.810E-10 BONE SUR 1.690E-13 7.776E-11 5.709E-10 2.890E-15-1.000E+00 1.410E-10 9.770E-11 THYROID 1.180E-13 5.462E-11 4.010E-10 2.030E-15-1.000E+00 6.870E-11 6.400E-12 REMAINDER 1.110E-13 5.569E-11 4.089E-10 2.070E-15-1.000E+00 2.120E-09 6.260E-09 EFFECTIVE 1.170E-13 5.812E-11 4.267E-10 2.160E-15-1.000E+00 1.310E-09 2.280E-09 SKIN(FGR) 1.660E-13 2.217E-10 1.628E-09 8.240E-15-1.000E+00 0.000E+00 0.000E+00 La-141 GONADS 2.330E-15 7.315E-13 9.675E-13 4.740E-17-1.000E+00 1.010E-11 3.770E-12 BREAST 2.640E-15 7.007E-13 9.267E-13 4.540E-17-1.000E+00 9.840E-12 7.070E-13 LUNGS 2.340E-15 6.713E-13 8.879E-13 4.350E-17-1.000E+00 6.460E-10 2.720E-13 RED MARR 2.310E-15 6.852E-13 9.063E-13 4.440E-17-1.000E+00 2.930E-11 1.070E-12 BONE SUR 3.490E-15 9.923E-13 1.312E-12 6.430E-17-1.000E+00 1.200E-10 6.060E-13 THYROID 2.390E-15 6.590E-13 8.716E-13 4.270E-17-1.000E+00 9.400E-12 5.290E-14 REMAINDER 2.260E-15 6.682E-13 8.838E-13 4.330E-17-1.000E+00 2.280E-10 1.240E-09 EFFECTIVE 2.390E-15 7.007E-13 9.267E-13 4.540E-17-1.000E+00 1.570E-10 3.740E-10
Numerical Applications Inc. Attachment 6 Page 125 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 SKIN(FGR) 6.580E-14 1.667E-10 2.204E-10 1.080E-14-1.000E+00 0.000E+00 0.000E+00 La-142 GONADS 1.400E-13 1.978E-11 2.034E-11 2.540E-15-1.000E+00 1.660E-11 6.990E-11 BREAST 1.570E-13 1.885E-11 1.938E-11 2.420E-15-1.000E+00 1.130E-11 1.540E-11 LUNGS 1.420E-13 1.846E-11 1.898E-11 2.370E-15-1.000E+00 3.010E-10 8.400E-12 RED MARR 1.420E-13 1.900E-11 1.954E-11 2.440E-15-1.000E+00 1.360E-11 1.930E-11 BONE SUR 1.950E-13 2.484E-11 2.554E-11 3.190E-15-1.000E+00 1.110E-11 7.400E-12 THYROID 1.450E-13 1.768E-11 1.818E-11 2.270E-15-1.000E+00 8.740E-12 1.160E-12 REMAINDER 1.380E-13 1.853E-11 1.906E-11 2.380E-15-1.000E+00 8.070E-11 5.200E-10 EFFECTIVE 1.440E-13 1.916E-11 1.970E-11 2.460E-15-1.000E+00 6.840E-11 1.790E-10 SKIN(FGR) 2.160E-13 9.111E-11 9.368E-11 1.170E-14-1.000E+00 0.000E+00 0.000E+00 Ce-141 GONADS 3.380E-15 2.213E-12 4.332E-11 7.710E-17-1.000E+00 5.540E-11 1.080E-10 BREAST 3.930E-15 2.170E-12 4.247E-11 7.560E-17-1.000E+00 4.460E-11 1.110E-11 LUNGS 3.170E-15 1.951E-12 3.820E-11 6.800E-17-1.000E+00 1.670E-08 1.430E-12 RED MARR 2.830E-15 1.860E-12 3.641E-11 6.480E-17-1.000E+00 8.960E-11 3.390E-11 BONE SUR 9.410E-15 5.166E-12 1.011E-10 1.800E-16-1.000E+00 2.540E-10 2.300E-11 THYROID 3.350E-15 2.003E-12 3.922E-11 6.980E-17-1.000E+00 2.550E-11 1.800E-13 REMAINDER 2.980E-15 1.894E-12 3.708E-11 6.600E-17-1.000E+00 1.260E-09 2.500E-09 EFFECTIVE 3.430E-15 2.118E-12 4.146E-11 7.380E-17-1.000E+00 2.420E-09 7.830E-10 SKIN(FGR) 1.020E-14 3.788E-12 7.416E-11 1.320E-16-1.000E+00 0.000E+00 0.000E+00 Ce-143 GONADS 1.280E-14 7.900E-12 4.958E-11 2.980E-16-1.000E+00 7.530E-11 2.120E-10 BREAST 1.470E-14 7.688E-12 4.825E-11 2.900E-16-1.000E+00 1.660E-11 2.320E-11 LUNGS 1.230E-14 6.893E-12 4.325E-11 2.600E-16-1.000E+00 3.880E-09 3.820E-12 RED MARR 1.170E-14 6.787E-12 4.259E-11 2.560E-16-1.000E+00 2.960E-11 5.070E-11 BONE SUR 2.520E-14 1.323E-11 8.302E-11 4.990E-16-1.000E+00 1.640E-11 1.610E-11 THYROID 1.280E-14 7.211E-12 4.525E-11 2.720E-16-1.000E+00 6.230E-12 4.350E-13 REMAINDER 1.170E-14 6.734E-12 4.226E-11 2.540E-16-1.000E+00 1.420E-09 3.890E-09 EFFECTIVE 1.290E-14 7.396E-12 4.642E-11 2.790E-16-1.000E+00 9.160E-10 1.230E-09 SKIN(FGR) 3.960E-14 1.058E-10 6.638E-10 3.990E-15-1.000E+00 0.000E+00 0.000E+00 Ce-144 GONADS 8.530E-16 6.328E-13 1.319E-11 6.088E-17-1.000E+00 2.390E-10 6.987E-11 BREAST 1.010E-15 6.274E-13 1.307E-11 5.922E-17-1.000E+00 3.480E-10 1.223E-11 LUNGS 7.690E-16 5.228E-13 1.089E-11 5.362E-17-1.000E+00 7.910E-07 6.551E-12 RED MARR 6.680E-16 4.755E-13 9.907E-12 5.247E-17-1.000E+00 2.880E-09 8.923E-11 BONE SUR 2.490E-15 1.646E-12 3.429E-11 1.127E-16-1.000E+00 4.720E-09 1.280E-10 THYROID 8.330E-16 5.529E-13 1.152E-11 5.418E-17-1.000E+00 2.920E-10 5.154E-12 REMAINDER 7.230E-16 5.086E-13 1.060E-11 5.283E-17-1.000E+00 1.910E-08 1.890E-08 EFFECTIVE 8.530E-16 5.909E-13 1.231E-11 5.766E-17-1.000E+00 1.010E-07 5.711E-09 SKIN(FGR) 2.930E-15 7.648E-13 1.594E-11 1.250E-14-1.000E+00 0.000E+00 0.000E+00 Pr-143 GONADS 2.130E-17 2.264E-14 4.032E-13 7.930E-19-1.000E+00 4.370E-18 8.990E-18 BREAST 2.550E-17 2.330E-14 4.149E-13 8.160E-19-1.000E+00 2.220E-18 1.090E-18 LUNGS 1.860E-17 1.642E-14 2.923E-13 5.750E-19-1.000E+00 1.330E-08 1.910E-19 RED MARR 1.620E-17 1.493E-14 2.659E-13 5.230E-19-1.000E+00 1.480E-11 1.030E-12 BONE SUR 5.930E-17 5.454E-14 9.711E-13 1.910E-18-1.000E+00 1.490E-11 1.030E-12 THYROID 2.050E-17 1.802E-14 3.208E-13 6.310E-19-1.000E+00 1.680E-18 2.660E-20 REMAINDER 1.760E-17 1.642E-14 2.923E-13 5.750E-19-1.000E+00 1.970E-09 4.220E-09 EFFECTIVE 2.100E-17 2.002E-14 3.564E-13 7.010E-19-1.000E+00 2.190E-09 1.270E-09 SKIN(FGR) 1.760E-14 5.711E-11 1.017E-09 2.000E-15-1.000E+00 0.000E+00 0.000E+00 Nd-147 GONADS 6.130E-15 4.218E-12 7.235E-11 1.480E-16-1.000E+00 8.410E-11 1.790E-10 BREAST 7.120E-15 4.132E-12 7.088E-11 1.450E-16-1.000E+00 3.450E-11 1.870E-11 LUNGS 5.820E-15 3.648E-12 6.257E-11 1.280E-16-1.000E+00 1.060E-08 2.440E-12 RED MARR 5.400E-15 3.505E-12 6.013E-11 1.230E-16-1.000E+00 9.190E-11 5.050E-11 BONE SUR 1.320E-14 8.265E-12 1.418E-10 2.900E-16-1.000E+00 3.260E-10 2.220E-11 THYROID 6.120E-15 3.876E-12 6.648E-11 1.360E-16-1.000E+00 1.820E-11 2.640E-13 REMAINDER 5.530E-15 3.562E-12 6.111E-11 1.250E-16-1.000E+00 1.760E-09 3.760E-09 EFFECTIVE 6.190E-15 3.961E-12 6.795E-11 1.390E-16-1.000E+00 1.850E-09 1.180E-09 SKIN(FGR) 1.950E-14 3.135E-11 5.377E-10 1.100E-15-1.000E+00 0.000E+00 0.000E+00 Np-239 GONADS 7.530E-15 4.691E-12 4.380E-11 1.710E-16-1.000E+00 7.450E-11 1.620E-10 BREAST 8.730E-15 4.636E-12 4.329E-11 1.690E-16-1.000E+00 1.630E-11 1.720E-11 LUNGS 7.180E-15 4.115E-12 3.842E-11 1.500E-16-1.000E+00 2.360E-09 2.400E-12 RED MARR 6.500E-15 4.005E-12 3.740E-11 1.460E-16-1.000E+00 2.080E-10 4.660E-11 BONE SUR 2.000E-14 1.001E-11 9.349E-11 3.650E-16-1.000E+00 2.030E-09 3.590E-11 THYROID 7.520E-15 4.197E-12 3.919E-11 1.530E-16-1.000E+00 7.620E-12 2.070E-13 REMAINDER 6.760E-15 4.005E-12 3.740E-11 1.460E-16-1.000E+00 9.590E-10 2.770E-09 EFFECTIVE 7.690E-15 4.471E-12 4.175E-11 1.630E-16-1.000E+00 6.780E-10 8.820E-10 SKIN(FGR) 1.600E-14 7.215E-12 6.737E-11 2.630E-16-1.000E+00 0.000E+00 0.000E+00 Pu-238 GONADS 6.560E-18 4.291E-14 9.011E-13 1.490E-18-1.000E+00 2.800E-05 2.330E-09
Numerical Applications Inc. Attachment 6 Page 126 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 BREAST 1.270E-17 5.558E-14 1.167E-12 1.930E-18-1.000E+00 1.000E-09 1.800E-13 LUNGS 1.060E-18 2.267E-15 4.759E-14 7.870E-20-1.000E+00 1.840E-05 8.640E-14 RED MARR 1.680E-18 5.587E-15 1.173E-13 1.940E-19-1.000E+00 1.520E-04 1.270E-08 BONE SUR 9.300E-18 3.514E-14 7.378E-13 1.220E-18-1.000E+00 1.900E-03 1.580E-07 THYROID 4.010E-18 9.792E-15 2.056E-13 3.400E-19-1.000E+00 9.620E-10 7.990E-14 REMAINDER 1.990E-18 9.216E-15 1.935E-13 3.200E-19-1.000E+00 7.020E-05 2.180E-08 EFFECTIVE 4.880E-18 2.413E-14 5.068E-13 8.380E-19-1.000E+00 1.060E-04 1.340E-08 SKIN(FGR) 4.090E-17 2.776E-13 5.830E-12 9.640E-18-1.000E+00 0.000E+00 0.000E+00 Pu-239 GONADS 4.840E-18 1.768E-14 3.713E-13 6.140E-19-1.000E+00 3.180E-05 2.640E-09 BREAST 7.550E-18 2.238E-14 4.699E-13 7.770E-19-1.000E+00 9.220E-10 1.210E-13 LUNGS 2.650E-18 2.267E-15 4.760E-14 7.870E-20-1.000E+00 1.730E-05 7.890E-14 RED MARR 2.670E-18 3.456E-15 7.258E-14 1.200E-19-1.000E+00 1.690E-04 1.410E-08 BONE SUR 9.470E-18 1.673E-14 3.514E-13 5.810E-19-1.000E+00 2.110E-03 1.760E-07 THYROID 3.880E-18 5.126E-15 1.077E-13 1.780E-19-1.000E+00 9.030E-10 7.500E-14 REMAINDER 2.860E-18 4.838E-15 1.016E-13 1.680E-19-1.000E+00 7.560E-05 2.120E-08 EFFECTIVE 4.240E-18 1.057E-14 2.220E-13 3.670E-19-1.000E+00 1.160E-05 1.400E-08 SKIN(FGR) 1.860E-17 1.057E-13 2.220E-12 3.670E-18-1.000E+00 0.000E+00 0.000E+00 Pu-240 GONADS 6.360E-18 4.118E-14 8.649E-13 1.430E-18-1.000E+00 3.180E-05 2.640E-09 BREAST 1.230E-17 5.328E-14 1.119E-12 1.850E-18-1.000E+00 9.510E-10 1.730E-13 LUNGS 1.090E-18 2.249E-15 4.723E-14 7.810E-20-1.000E+00 1.730E-05 8.220E-14 RED MARR 1.650E-18 5.386E-15 1.131E-13 1.870E-19-1.000E+00 1.690E-04 1.410E-08 BONE SUR 9.260E-18 3.398E-14 7.137E-13 1.180E-18-1.000E+00 2.110E-03 1.760E-07 THYROID 3.920E-18 9.446E-15 1.984E-13 3.280E-19-1.000E+00 9.050E-10 7.510E-14 REMAINDER 1.960E-18 8.870E-15 1.863E-13 3.080E-19-1.000E+00 7.560E-05 2.130E-08 EFFECTIVE 4.750E-18 2.313E-14 4.857E-13 8.030E-19-1.000E+00 1.160E-04 1.400E-08 SKIN(FGR) 3.920E-17 2.644E-13 5.552E-12 9.180E-18-1.000E+00 0.000E+00 0.000E+00 Pu-241 GONADS 7.190E-20 6.653E-17 1.396E-15 2.310E-21-1.000E+00 6.820E-07 5.660E-11 BREAST 8.670E-20 7.229E-17 1.517E-15 2.510E-21-1.000E+00 3.060E-11 2.790E-15 LUNGS 6.480E-20 4.090E-17 8.584E-16 1.420E-21-1.000E+00 7.420E-09 4.480E-15 RED MARR 5.630E-20 4.003E-17 8.403E-16 1.390E-21-1.000E+00 3.360E-06 2.780E-10 BONE SUR 2.190E-19 1.385E-16 2.908E-15 4.810E-21-1.000E+00 4.200E-05 3.480E-09 THYROID 6.980E-20 4.522E-17 9.491E-16 1.570E-21-1.000E+00 1.240E-11 1.010E-15 REMAINDER 6.090E-20 4.291E-17 9.007E-16 1.490E-21-1.000E+00 1.310E-06 1.850E-10 EFFECTIVE 7.250E-20 5.558E-17 1.167E-15 1.930E-21-1.000E+00 2.230E-06 2.070E-10 SKIN(FGR) 1.170E-19 2.033E-16 4.268E-15 7.060E-21-1.000E+00 0.000E+00 0.000E+00 Am-241 GONADS 8.580E-16 9.360E-13 1.966E-11 3.250E-17-1.000E+00 3.250E-05 2.700E-07 BREAST 1.070E-15 1.014E-12 2.129E-11 3.520E-17-1.000E+00 2.670E-09 2.620E-11 LUNGS 6.740E-16 5.789E-13 1.216E-11 2.010E-17-1.000E+00 1.840E-05 3.360E-11 RED MARR 5.210E-16 4.838E-13 1.016E-11 1.680E-17-1.000E+00 1.740E-04 1.450E-06 BONE SUR 2.870E-15 2.678E-12 5.625E-11 9.300E-17-1.000E+00 2.170E-03 1.810E-05 THYROID 7.830E-16 6.365E-13 1.337E-11 2.210E-17-1.000E+00 1.600E-09 1.320E-11 REMAINDER 6.340E-16 5.933E-13 1.246E-11 2.060E-17-1.000E+00 7.820E-05 6.660E-07 EFFECTIVE 8.180E-16 7.920E-13 1.663E-11 2.750E-17-1.000E+00 1.200E-04 9.840E-07 SKIN(FGR) 1.280E-15 2.396E-12 5.032E-11 8.320E-17-1.000E+00 0.000E+00 0.000E+00 Cm-242 GONADS 7.830E-18 4.893E-14 1.013E-12 1.700E-18-1.000E+00 5.700E-07 5.200E-09 BREAST 1.480E-17 6.159E-14 1.275E-12 2.140E-18-1.000E+00 9.440E-10 8.950E-12 LUNGS 1.130E-18 3.022E-15 6.257E-14 1.050E-19-1.000E+00 1.550E-05 8.840E-12 RED MARR 1.890E-18 6.562E-15 1.359E-13 2.280E-19-1.000E+00 3.900E-06 3.570E-08 BONE SUR 1.060E-17 4.231E-14 8.759E-13 1.470E-18-1.000E+00 4.870E-05 4.460E-07 THYROID 4.910E-18 1.261E-14 2.610E-13 4.380E-19-1.000E+00 9.410E-10 8.820E-12 REMAINDER 2.270E-18 1.079E-14 2.235E-13 3.750E-19-1.000E+00 2.450E-06 4.020E-08 EFFECTIVE 5.690E-18 2.751E-14 5.697E-13 9.560E-19-1.000E+00 4.670E-06 3.100E-08 SKIN(FGR) 4.290E-17 2.700E-13 5.589E-12 9.380E-18-1.000E+00 0.000E+00 0.000E+00 Cm-244 GONADS 6.900E-18 4.522E-14 9.492E-13 1.570E-18-1.000E+00 1.590E-05 1.330E-07 BREAST 1.330E-17 5.702E-14 1.197E-12 1.980E-18-1.000E+00 1.040E-09 8.820E-12 LUNGS 7.080E-19 2.592E-15 5.441E-14 9.000E-20-1.000E+00 1.930E-05 8.810E-12 RED MARR 1.460E-18 5.875E-15 1.233E-13 2.040E-19-1.000E+00 9.380E-05 7.820E-07 BONE SUR 8.820E-18 3.859E-14 8.101E-13 1.340E-18-1.000E+00 1.170E-03 9.770E-06 THYROID 4.190E-18 1.146E-14 2.406E-13 3.980E-19-1.000E+00 1.010E-09 8.440E-12 REMAINDER 1.810E-18 9.821E-15 2.062E-13 3.410E-19-1.000E+00 4.780E-05 4.150E-07 EFFECTIVE 4.910E-18 2.529E-14 5.308E-13 8.780E-19-1.000E+00 6.700E-05 5.450E-07 SKIN(FGR) 3.910E-17 2.506E-13 5.260E-12 8.700E-18-1.000E+00 0.000E+00 0.000E+00 I-130 GONADS 1.010E-13 2.867E-11 5.828E-10 9.970E-16-1.000E+00 2.810E-11 1.040E-09 BREAST 1.160E-13 2.737E-11 5.565E-10 9.520E-16-1.000E+00 4.870E-11 1.790E-10 LUNGS 1.010E-13 2.617E-11 5.319E-10 9.100E-16-1.000E+00 6.030E-10 8.530E-11 RED MARR 9.820E-14 2.671E-11 5.430E-10 9.290E-16-1.000E+00 4.550E-11 2.600E-10
Numerical Applications Inc. Attachment 6 Page 127 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 BONE SUR 1.680E-13 3.795E-11 7.716E-10 1.320E-15-1.000E+00 4.030E-11 1.250E-10 THYROID 1.040E-13 2.720E-11 5.530E-10 9.460E-16-1.000E+00 1.990E-08 6.310E-11 REMAINDER 9.660E-14 2.585E-11 5.255E-10 8.990E-16-1.000E+00 8.020E-11 1.580E-09 EFFECTIVE 1.040E-13 2.732E-11 5.553E-10 9.500E-16-1.000E+00 7.140E-10 8.090E-10 SKIN(FGR) 1.360E-13 3.278E-11 6.664E-10 1.140E-15-1.000E+00 0.000E+00 0.000E+00 Kr-83m GONADS 1.710E-18 7.056E-11 1.480E-09 2.450E-15-1.000E+00 0.000E+00 3.190E-09 BREAST 5.050E-18 6.739E-11 1.413E-09 2.340E-15-1.000E+00 0.000E+00 1.100E-09 LUNGS 1.640E-19 6.537E-11 1.371E-09 2.270E-15-1.000E+00 0.000E+00 8.770E-10 RED MARR 3.830E-19 6.710E-11 1.407E-09 2.330E-15-1.000E+00 0.000E+00 1.320E-09 BONE SUR 2.250E-18 8.956E-11 1.879E-09 3.110E-15-1.000E+00 0.000E+00 9.390E-10 THYROID 6.430E-19 6.480E-11 1.359E-09 2.250E-15-1.000E+00 0.000E+00 7.880E-10 REMAINDER 5.300E-19 6.508E-11 1.365E-09 2.260E-15-1.000E+00 0.000E+00 4.970E-09 EFFECTIVE 1.500E-18 6.768E-11 1.419E-09 2.350E-15-1.000E+00 0.000E+00 2.770E-09 SKIN(FGR) 3.560E-17 7.948E-11 1.667E-09 2.760E-15-1.000E+00 0.000E+00 0.000E+00 Xe-138 GONADS 5.590E-14 8.121E-14 1.704E-12 2.820E-18-1.000E+00 0.000E+00 0.000E+00 BREAST 6.320E-14 7.891E-14 1.656E-12 2.740E-18-1.000E+00 0.000E+00 0.000E+00 LUNGS 5.660E-14 7.056E-14 1.481E-12 2.450E-18-1.000E+00 0.000E+00 0.000E+00 RED MARR 5.600E-14 6.998E-14 1.469E-12 2.430E-18-1.000E+00 0.000E+00 0.000E+00 BONE SUR 8.460E-14 1.287E-13 2.702E-12 4.470E-18-1.000E+00 0.000E+00 0.000E+00 THYROID 5.770E-14 7.459E-14 1.565E-12 2.590E-18-1.000E+00 0.000E+00 0.000E+00 REMAINDER 5.490E-14 6.941E-14 1.457E-12 2.410E-18-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 5.770E-14 7.603E-14 1.596E-12 2.640E-18-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.070E-13 2.304E-11 4.835E-10 8.000E-16-1.000E+00 0.000E+00 0.000E+00 Xe-131m GONADS 4.570E-16 2.594E-12 3.653E-12 1.570E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 6.020E-16 2.527E-12 3.560E-12 1.530E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 2.670E-16 2.379E-12 3.351E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 2.270E-16 2.346E-12 3.304E-12 1.420E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.060E-15 5.286E-12 7.446E-12 3.200E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 3.910E-16 2.395E-12 3.374E-12 1.450E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 2.710E-16 2.313E-12 3.257E-12 1.400E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 3.890E-16 2.511E-12 3.537E-12 1.520E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 4.820E-15 2.247E-11 3.164E-11 1.360E-15-1.000E+00 0.000E+00 0.000E+00 Xe-133m GONADS 1.420E-15 4.962E-12 5.026E-12 7.610E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 1.700E-15 4.740E-12 4.802E-12 7.270E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.190E-15 4.603E-12 4.663E-12 7.060E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.100E-15 4.708E-12 4.769E-12 7.220E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 3.230E-15 6.514E-12 6.598E-12 9.990E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 1.360E-15 4.473E-12 4.531E-12 6.860E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.150E-15 4.590E-12 4.650E-12 7.040E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.370E-15 4.773E-12 4.835E-12 7.320E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.040E-14 8.802E-11 8.916E-11 1.350E-14-1.000E+00 0.000E+00 0.000E+00 Xe-135m GONADS 2.000E-14 2.278E-11 2.655E-11 1.800E-15-1.000E+00 0.000E+00 0.000E+00 BREAST 2.290E-14 2.177E-11 2.537E-11 1.720E-15-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.980E-14 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.910E-14 2.190E-11 2.552E-11 1.730E-15-1.000E+00 0.000E+00 0.000E+00 BONE SUR 3.500E-14 2.886E-11 3.363E-11 2.280E-15-1.000E+00 0.000E+00 0.000E+00 THYROID 2.040E-14 2.012E-11 2.345E-11 1.590E-15-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.890E-14 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 2.040E-14 2.202E-11 2.567E-11 1.740E-15-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 2.970E-14 5.607E-11 6.534E-11 4.430E-15-1.000E+00 0.000E+00 0.000E+00 Cs-138 GONADS 1.170E-13 2.788E-12 5.187E-11 9.740E-17-1.000E+00 3.280E-12 2.150E-09 BREAST 1.330E-13 2.662E-12 4.953E-11 9.300E-17-1.000E+00 4.020E-12 2.140E-09 LUNGS 1.190E-13 2.553E-12 4.750E-11 8.920E-17-1.000E+00 1.590E-10 2.140E-09 RED MARR 1.180E-13 2.619E-12 4.873E-11 9.150E-17-1.000E+00 3.950E-12 3.720E-09 BONE SUR 1.700E-13 3.635E-12 6.764E-11 1.270E-16-1.000E+00 3.550E-12 6.860E-09 THYROID 1.210E-13 2.599E-12 4.836E-11 9.080E-17-1.000E+00 3.570E-12 2.140E-09 REMAINDER 1.150E-13 2.542E-12 4.729E-11 8.880E-17-1.000E+00 2.060E-11 2.330E-09 EFFECTIVE 1.210E-13 2.665E-12 4.958E-11 9.310E-17-1.000E+00 2.740E-11 2.530E-09 SKIN(FGR) 2.170E-13 2.210E-10 4.111E-09 7.720E-15-1.000E+00 0.000E+00 0.000E+00 Cs-134m GONADS 9.300E-16 7.155E-14 1.436E-12 2.490E-18-1.000E+00 3.610E-12 8.050E-12 BREAST 1.120E-15 7.212E-14 1.447E-12 2.510E-18-1.000E+00 3.390E-12 7.980E-12 LUNGS 7.840E-16 5.689E-14 1.142E-12 1.980E-18-1.000E+00 6.400E-11 7.970E-12 RED MARR 6.810E-16 5.345E-14 1.073E-12 1.860E-18-1.000E+00 3.760E-12 1.080E-10 BONE SUR 2.610E-15 1.560E-13 3.131E-12 5.430E-18-1.000E+00 3.550E-12 1.610E-10 THYROID 8.880E-16 6.063E-14 1.217E-12 2.110E-18-1.000E+00 3.340E-12 7.970E-12 REMAINDER 7.450E-16 5.603E-14 1.124E-12 1.950E-18-1.000E+00 6.900E-12 8.250E-09
Numerical Applications Inc. Attachment 6 Page 128 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 EFFECTIVE 9.050E-16 6.523E-14 1.309E-12 2.270E-18-1.000E+00 1.180E-11 2.500E-09 SKIN(FGR) 2.880E-15 1.914E-10 3.841E-09 6.660E-15-1.000E+00 0.000E+00 0.000E+00 Rb-88 GONADS 3.260E-14 9.590E-15 2.014E-13 3.330E-19-1.000E+00 1.310E-12 5.040E-11 BREAST 3.670E-14 1.008E-14 2.116E-13 3.500E-19-1.000E+00 1.430E-12 5.040E-11 LUNGS 3.310E-14 6.307E-15 1.324E-13 2.190E-19-1.000E+00 1.470E-10 5.040E-11 RED MARR 3.300E-14 5.558E-15 1.167E-13 1.930E-19-1.000E+00 1.450E-12 6.450E-09 BONE SUR 4.620E-14 2.393E-14 5.025E-13 8.310E-19-1.000E+00 1.470E-12 1.390E-08 THYROID 3.370E-14 7.171E-15 1.506E-13 2.490E-19-1.000E+00 1.370E-12 5.040E-11 REMAINDER 3.210E-14 6.422E-15 1.348E-13 2.230E-19-1.000E+00 1.380E-11 6.700E-09 EFFECTIVE 3.360E-14 8.179E-15 1.717E-13 2.840E-19-1.000E+00 2.260E-11 3.230E-09 SKIN(FGR) 1.830E-13 4.032E-12 8.465E-11 1.400E-16-1.000E+00 0.000E+00 0.000E+00 Rb-89 GONADS 1.030E-13 2.155E-11 5.062E-11 1.026E-15-1.000E+00 1.340E-12 2.520E-10 BREAST 1.170E-13 2.059E-11 4.838E-11 9.806E-16-1.000E+00 1.730E-12 3.676E-11 LUNGS 1.040E-13 1.970E-11 4.626E-11 9.376E-16-1.000E+00 6.800E-11 1.055E-11 RED MARR 1.040E-13 2.011E-11 4.722E-11 9.570E-16-1.000E+00 2.020E-12 5.659E-11 BONE SUR 1.480E-13 2.852E-11 6.709E-11 1.360E-15-1.000E+00 2.540E-12 2.070E-11 THYROID 1.070E-13 2.035E-11 4.782E-11 9.693E-16-1.000E+00 1.610E-12 1.968E-12 REMAINDER 1.010E-13 1.948E-11 4.573E-11 9.268E-16-1.000E+00 8.140E-12 2.557E-09 EFFECTIVE 1.060E-13 2.057E-11 4.832E-11 9.793E-16-1.000E+00 1.160E-11 8.455E-10 SKIN(FGR) 1.870E-13 1.748E-10 3.987E-10 8.080E-15-1.000E+00 0.000E+00 0.000E+00 Sb-124 GONADS 8.890E-14 1.593E-11 1.830E-11 1.300E-15-1.000E+00 1.040E-09 8.180E-11 BREAST 1.010E-13 1.520E-11 1.745E-11 1.240E-15-1.000E+00 8.940E-10 1.700E-11 LUNGS 8.970E-14 1.483E-11 1.703E-11 1.210E-15-1.000E+00 4.140E-08 7.220E-12 RED MARR 8.850E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 1.090E-09 2.290E-11 BONE SUR 1.340E-13 2.010E-11 2.308E-11 1.640E-15-1.000E+00 1.240E-09 8.490E-12 THYROID 9.150E-14 1.446E-11 1.661E-11 1.180E-15-1.000E+00 6.740E-10 1.300E-12 REMAINDER 8.660E-14 1.471E-11 1.689E-11 1.200E-15-1.000E+00 4.180E-09 1.720E-09 EFFECTIVE 9.150E-14 1.532E-11 1.759E-11 1.250E-15-1.000E+00 6.800E-09 5.430E-10 SKIN(FGR) 1.260E-13 2.280E-11 2.618E-11 1.860E-15-1.000E+00 0.000E+00 0.000E+00 Sb-125 GONADS 1.980E-14 1.586E-13 1.601E-12 5.750E-18-1.000E+00 3.600E-10 1.430E-14 BREAST 2.270E-14 1.578E-13 1.593E-12 5.720E-18-1.000E+00 4.160E-10 1.270E-14 LUNGS 1.950E-14 1.313E-13 1.326E-12 4.760E-18-1.000E+00 2.170E-08 1.260E-14 RED MARR 1.870E-14 1.261E-13 1.273E-12 4.570E-18-1.000E+00 5.350E-10 3.700E-13 BONE SUR 3.530E-14 3.228E-13 3.259E-12 1.170E-17-1.000E+00 9.780E-10 3.670E-13 THYROID 2.010E-14 1.385E-13 1.398E-12 5.020E-18-1.000E+00 3.240E-10 1.260E-14 REMAINDER 1.860E-14 1.291E-13 1.303E-12 4.680E-18-1.000E+00 1.450E-09 9.680E-09 EFFECTIVE 2.020E-14 1.468E-13 1.482E-12 5.320E-18-1.000E+00 3.300E-09 2.910E-09 SKIN(FGR) 2.650E-14 2.897E-10 2.924E-09 1.050E-14-1.000E+00 0.000E+00 0.000E+00 Sb-126 GONADS 1.350E-13 1.756E-13 3.546E-12 6.110E-18-1.000E+00 1.320E-09 3.540E-12 BREAST 1.530E-13 1.713E-13 3.459E-12 5.960E-18-1.000E+00 6.440E-10 5.540E-13 LUNGS 1.340E-13 1.526E-13 3.082E-12 5.310E-18-1.000E+00 1.380E-08 2.020E-13 RED MARR 1.300E-13 1.521E-13 3.070E-12 5.290E-18-1.000E+00 7.970E-10 6.590E-12 BONE SUR 2.220E-13 2.903E-13 5.862E-12 1.010E-17-1.000E+00 6.750E-10 6.130E-12 THYROID 1.370E-13 1.564E-13 3.157E-12 5.440E-18-1.000E+00 4.800E-10 1.290E-13 REMAINDER 1.280E-13 1.509E-13 3.047E-12 5.250E-18-1.000E+00 3.190E-09 8.570E-09 EFFECTIVE 1.370E-13 1.650E-13 3.332E-12 5.740E-18-1.000E+00 3.170E-09 2.570E-09 SKIN(FGR) 1.730E-13 1.989E-10 4.016E-09 6.920E-15-1.000E+00 0.000E+00 0.000E+00 Te-131 GONADS 1.990E-14 3.855E-12 4.872E-12 2.650E-16-1.000E+00 6.140E-12 1.960E-11 BREAST 2.280E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 5.530E-12 3.550E-12 LUNGS 1.960E-14 3.535E-12 4.468E-12 2.430E-16-1.000E+00 2.540E-10 1.390E-12 RED MARR 1.880E-14 3.608E-12 4.560E-12 2.480E-16-1.000E+00 6.640E-12 4.910E-12 BONE SUR 3.800E-14 5.091E-12 6.435E-12 3.500E-16-1.000E+00 6.210E-12 1.750E-12 THYROID 2.030E-14 3.579E-12 4.523E-12 2.460E-16-1.000E+00 2.630E-09 1.770E-13 REMAINDER 1.870E-14 3.506E-12 4.431E-12 2.410E-16-1.000E+00 5.420E-11 1.700E-09 EFFECTIVE 2.040E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 1.290E-10 5.150E-10 SKIN(FGR) 6.890E-14 2.022E-10 2.556E-10 1.390E-14-1.000E+00 0.000E+00 0.000E+00 Te-133 GONADS 4.490E-14 2.108E-12 4.989E-12 9.510E-17-1.000E+00 6.700E-13 2.200E-11 BREAST 5.100E-14 2.026E-12 4.794E-12 9.140E-17-1.000E+00 8.480E-13 3.130E-12 LUNGS 4.470E-14 1.937E-12 4.585E-12 8.740E-17-1.000E+00 4.390E-11 8.670E-13 RED MARR 4.360E-14 1.972E-12 4.669E-12 8.900E-17-1.000E+00 8.390E-13 4.930E-12 BONE SUR 7.500E-14 2.948E-12 6.977E-12 1.330E-16-1.000E+00 7.490E-13 1.730E-12 THYROID 4.590E-14 1.908E-12 4.516E-12 8.610E-17-1.000E+00 5.910E-10 1.260E-13 REMAINDER 4.290E-14 1.919E-12 4.543E-12 8.660E-17-1.000E+00 5.020E-12 4.090E-09 EFFECTIVE 4.600E-14 2.021E-12 4.784E-12 9.120E-17-1.000E+00 2.490E-11 1.230E-09 SKIN(FGR) 1.060E-13 2.726E-10 6.452E-10 1.230E-14-1.000E+00 0.000E+00 0.000E+00 Te-134
Numerical Applications Inc. Attachment 6 Page 129 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 GONADS 4.160E-14 2.182E-11 4.421E-10 7.590E-16-1.000E+00 9.000E-12 8.160E-10 BREAST 4.750E-14 2.084E-11 4.223E-10 7.250E-16-1.000E+00 8.720E-12 1.050E-10 LUNGS 4.100E-14 1.989E-11 4.030E-10 6.920E-16-1.000E+00 6.020E-11 2.340E-11 RED MARR 3.940E-14 2.030E-11 4.112E-10 7.060E-16-1.000E+00 9.300E-12 2.140E-10 BONE SUR 7.560E-14 2.875E-11 5.824E-10 1.000E-15-1.000E+00 8.580E-12 4.860E-10 THYROID 4.230E-14 2.076E-11 4.205E-10 7.220E-16-1.000E+00 5.540E-10 8.270E-12 REMAINDER 3.910E-14 1.963E-11 3.978E-10 6.830E-16-1.000E+00 1.880E-11 2.530E-09 EFFECTIVE 4.240E-14 2.078E-11 4.211E-10 7.230E-16-1.000E+00 3.440E-11 1.020E-09 SKIN(FGR) 6.350E-14 2.561E-11 5.190E-10 8.910E-16-1.000E+00 0.000E+00 0.000E+00 Te-125m GONADS 5.960E-16 2.179E-11 7.799E-11 9.253E-16-1.000E+00 7.930E-11 6.228E-10 BREAST 8.480E-16 2.083E-11 7.455E-11 8.846E-16-1.000E+00 7.080E-11 8.137E-11 LUNGS 2.230E-16 1.992E-11 7.127E-11 8.456E-16-1.000E+00 1.040E-08 1.770E-11 RED MARR 1.860E-16 2.034E-11 7.279E-11 8.634E-16-1.000E+00 1.150E-09 1.302E-10 BONE SUR 1.220E-15 2.881E-11 1.031E-10 1.224E-15-1.000E+00 1.180E-08 4.558E-11 THYROID 4.640E-16 2.061E-11 7.377E-11 8.755E-16-1.000E+00 3.870E-11 2.671E-12 REMAINDER 2.590E-16 1.966E-11 7.035E-11 8.345E-16-1.000E+00 6.750E-10 6.990E-09 EFFECTIVE 4.530E-16 2.078E-11 7.438E-11 8.824E-16-1.000E+00 1.970E-09 2.283E-09 SKIN(FGR) 1.940E-15 2.281E-10 8.148E-10 9.587E-15-1.000E+00 0.000E+00 0.000E+00 Te-133m GONADS 1.120E-13 2.253E-11 4.435E-10 7.850E-16-1.000E+00 8.970E-12 8.050E-10 BREAST 1.270E-13 2.150E-11 4.231E-10 7.490E-16-1.000E+00 7.820E-12 1.070E-10 LUNGS 1.120E-13 2.055E-11 4.045E-10 7.160E-16-1.000E+00 1.820E-10 2.740E-11 RED MARR 1.090E-13 2.101E-11 4.135E-10 7.320E-16-1.000E+00 8.320E-12 1.990E-10 BONE SUR 1.750E-13 2.957E-11 5.819E-10 1.030E-15-1.000E+00 6.940E-12 2.940E-10 THYROID 1.150E-13 2.144E-11 4.220E-10 7.470E-16-1.000E+00 2.610E-09 1.180E-11 REMAINDER 1.070E-13 2.032E-11 4.000E-10 7.080E-16-1.000E+00 4.140E-11 1.470E-09 EFFECTIVE 1.140E-13 2.147E-11 4.226E-10 7.480E-16-1.000E+00 1.170E-10 6.950E-10 SKIN(FGR) 1.740E-13 2.598E-11 5.112E-10 9.050E-16-1.000E+00 0.000E+00 0.000E+00 Ba-141 GONADS 4.060E-14 4.282E-12 4.403E-11 1.550E-16-1.000E+00 1.410E-12 2.180E-10 BREAST 4.630E-14 4.116E-12 4.233E-11 1.490E-16-1.000E+00 1.470E-12 3.430E-11 LUNGS 4.030E-14 3.867E-12 3.977E-11 1.400E-16-1.000E+00 1.160E-10 1.510E-11 RED MARR 3.910E-14 3.923E-12 4.034E-11 1.420E-16-1.000E+00 2.490E-12 8.320E-11 BONE SUR 7.170E-14 6.105E-12 6.278E-11 2.210E-16-1.000E+00 4.730E-12 6.320E-11 THYROID 4.150E-14 4.033E-12 4.147E-11 1.460E-16-1.000E+00 1.330E-12 1.030E-11 REMAINDER 3.870E-14 3.812E-12 3.920E-11 1.380E-16-1.000E+00 2.270E-11 4.280E-09 EFFECTIVE 4.160E-14 4.061E-12 4.176E-11 1.470E-16-1.000E+00 2.180E-11 1.360E-09 SKIN(FGR) 1.070E-13 1.039E-10 1.068E-09 3.760E-15-1.000E+00 0.000E+00 0.000E+00 Ba-137m GONADS 2.820E-14 2.334E-12 3.877E-12 1.240E-16-1.000E+00 0.000E+00 9.750E-12 BREAST 3.220E-14 2.258E-12 3.752E-12 1.200E-16-1.000E+00 0.000E+00 3.570E-12 LUNGS 2.800E-14 2.127E-12 3.533E-12 1.130E-16-1.000E+00 0.000E+00 3.140E-12 RED MARR 2.730E-14 2.070E-12 3.439E-12 1.100E-16-1.000E+00 0.000E+00 6.290E-12 BONE SUR 4.630E-14 5.383E-12 8.942E-12 2.860E-16-1.000E+00 0.000E+00 4.060E-12 THYROID 2.880E-14 2.145E-12 3.564E-12 1.140E-16-1.000E+00 0.000E+00 8.460E-11 REMAINDER 2.680E-14 2.070E-12 3.439E-12 1.100E-16-1.000E+00 0.000E+00 3.340E-11 EFFECTIVE 2.880E-14 2.277E-12 3.783E-12 1.210E-16-1.000E+00 0.000E+00 1.680E-11 SKIN(FGR) 3.730E-14 2.710E-12 4.502E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 Pd-109 GONADS 2.710E-16 1.404E-11 2.783E-10 4.892E-16-1.000E+00 2.130E-12 5.720E-10 BREAST 3.520E-16 1.350E-11 2.677E-10 4.705E-16-1.000E+00 5.110E-13 1.200E-10 LUNGS 1.940E-16 1.273E-11 2.522E-10 4.432E-16-1.000E+00 1.200E-09 7.310E-11 RED MARR 1.740E-16 1.287E-11 2.551E-10 4.483E-16-1.000E+00 9.820E-13 1.660E-10 BONE SUR 7.020E-16 1.958E-11 3.882E-10 6.823E-16-1.000E+00 9.580E-13 9.631E-11 THYROID 2.460E-16 1.331E-11 2.639E-10 4.638E-16-1.000E+00 1.550E-13 6.250E-11 REMAINDER 1.920E-16 1.248E-11 2.472E-10 4.346E-16-1.000E+00 5.040E-10 2.110E-09 EFFECTIVE 2.510E-16 1.332E-11 2.641E-10 4.642E-16-1.000E+00 2.960E-10 8.271E-10 SKIN(FGR) 2.150E-14 1.785E-11 3.543E-10 6.229E-16-1.000E+00 0.000E+00 0.000E+00 Rh-106 GONADS 1.010E-14 1.327E-11 1.861E-11 8.070E-16-1.000E+00 0.000E+00 9.670E-11 BREAST 1.160E-14 1.271E-11 1.783E-11 7.730E-16-1.000E+00 0.000E+00 1.590E-11 LUNGS 1.010E-14 1.210E-11 1.697E-11 7.360E-16-1.000E+00 0.000E+00 6.210E-12 RED MARR 9.750E-15 1.230E-11 1.725E-11 7.480E-16-1.000E+00 0.000E+00 2.350E-11 BONE SUR 1.720E-14 1.809E-11 2.537E-11 1.100E-15-1.000E+00 0.000E+00 8.890E-12 THYROID 1.030E-14 1.260E-11 1.766E-11 7.660E-16-1.000E+00 0.000E+00 1.820E-12 REMAINDER 9.630E-15 1.189E-11 1.667E-11 7.230E-16-1.000E+00 0.000E+00 8.540E-10 EFFECTIVE 1.040E-14 1.265E-11 1.773E-11 7.690E-16-1.000E+00 0.000E+00 2.870E-10 SKIN(FGR) 1.090E-13 7.368E-11 1.033E-10 4.480E-15-1.000E+00 0.000E+00 0.000E+00 Rh-103m GONADS 1.250E-17 6.411E-12 1.340E-10 2.230E-16-1.000E+00 8.910E-14 1.640E-09 BREAST 2.150E-17 6.152E-12 1.286E-10 2.140E-16-1.000E+00 8.800E-14 1.440E-09 LUNGS 1.870E-18 5.836E-12 1.220E-10 2.030E-16-1.000E+00 7.750E-12 1.420E-09
Numerical Applications Inc. Attachment 6 Page 130 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 RED MARR 2.820E-18 5.893E-12 1.232E-10 2.050E-16-1.000E+00 8.840E-14 1.460E-09 BONE SUR 1.760E-17 8.883E-12 1.856E-10 3.090E-16-1.000E+00 8.730E-14 1.430E-09 THYROID 8.550E-18 6.066E-12 1.268E-10 2.110E-16-1.000E+00 8.490E-14 1.410E-09 REMAINDER 3.680E-18 5.721E-12 1.196E-10 1.990E-16-1.000E+00 1.340E-12 2.110E-08 EFFECTIVE 8.800E-18 6.095E-12 1.274E-10 2.120E-16-1.000E+00 1.380E-12 7.400E-09 SKIN(FGR) 4.490E-17 4.082E-10 8.531E-09 1.420E-14-1.000E+00 0.000E+00 0.000E+00 Tc-101 GONADS 1.570E-14 2.127E-12 1.411E-11 7.980E-17-1.000E+00 2.500E-13 5.800E-11 BREAST 1.800E-14 2.063E-12 1.369E-11 7.740E-17-1.000E+00 3.030E-13 8.970E-12 LUNGS 1.540E-14 1.935E-12 1.284E-11 7.260E-17-1.000E+00 2.830E-11 3.860E-12 RED MARR 1.460E-14 1.946E-12 1.291E-11 7.300E-17-1.000E+00 3.190E-13 1.470E-11 BONE SUR 3.210E-14 3.332E-12 2.210E-11 1.250E-16-1.000E+00 2.800E-13 6.750E-12 THYROID 1.590E-14 1.983E-12 1.316E-11 7.440E-17-1.000E+00 7.720E-12 2.910E-12 REMAINDER 1.470E-14 1.885E-12 1.250E-11 7.070E-17-1.000E+00 3.520E-12 1.270E-09 EFFECTIVE 1.610E-14 2.031E-12 1.347E-11 7.620E-17-1.000E+00 4.840E-12 3.990E-10 SKIN(FGR) 4.770E-14 4.691E-12 3.112E-11 1.760E-16-1.000E+00 0.000E+00 0.000E+00 Eu-154 GONADS 6.000E-14 1.985E-11 2.441E-10 7.100E-16-1.000E+00 1.170E-08 6.140E-10 BREAST 6.810E-14 1.904E-11 2.341E-10 6.810E-16-1.000E+00 1.550E-08 7.600E-11 LUNGS 5.990E-14 1.809E-11 2.224E-10 6.470E-16-1.000E+00 7.920E-08 1.570E-11 RED MARR 5.870E-14 1.834E-11 2.255E-10 6.560E-16-1.000E+00 1.060E-07 1.330E-10 BONE SUR 9.430E-14 2.720E-11 3.345E-10 9.730E-16-1.000E+00 5.230E-07 5.240E-11 THYROID 6.150E-14 1.884E-11 2.317E-10 6.740E-16-1.000E+00 7.140E-09 4.640E-12 REMAINDER 5.750E-14 1.775E-11 2.183E-10 6.350E-16-1.000E+00 1.130E-07 5.870E-09 EFFECTIVE 6.140E-14 1.890E-11 2.324E-10 6.760E-16-1.000E+00 7.730E-08 1.950E-09 SKIN(FGR) 8.290E-14 7.967E-11 9.799E-10 2.850E-15-1.000E+00 0.000E+00 0.000E+00 Eu-155 GONADS 2.490E-15 2.336E-11 3.231E-11 1.440E-15-1.000E+00 3.560E-10 1.510E-10 BREAST 2.950E-15 2.222E-11 3.074E-11 1.370E-15-1.000E+00 6.140E-10 2.560E-11 LUNGS 2.220E-15 2.141E-11 2.962E-11 1.320E-15-1.000E+00 1.190E-08 9.390E-12 RED MARR 1.850E-15 2.190E-11 3.029E-11 1.350E-15-1.000E+00 1.430E-08 3.670E-11 BONE SUR 8.090E-15 3.033E-11 4.196E-11 1.870E-15-1.000E+00 1.520E-07 1.340E-11 THYROID 2.410E-15 2.174E-11 3.007E-11 1.340E-15-1.000E+00 2.400E-10 1.470E-12 REMAINDER 2.070E-15 2.125E-11 2.939E-11 1.310E-15-1.000E+00 1.110E-08 1.450E-09 EFFECTIVE 2.490E-15 2.238E-11 3.096E-11 1.380E-15-1.000E+00 1.120E-08 4.840E-10 SKIN(FGR) 3.390E-15 8.273E-11 1.144E-10 5.100E-15-1.000E+00 0.000E+00 0.000E+00 Eu-156 GONADS 6.570E-14 1.191E-13 2.661E-13 5.480E-18-1.000E+00 6.120E-10 4.020E-12 BREAST 7.420E-14 1.158E-13 2.588E-13 5.330E-18-1.000E+00 3.640E-10 3.000E-12 LUNGS 6.630E-14 1.060E-13 2.370E-13 4.880E-18-1.000E+00 1.840E-08 2.890E-12 RED MARR 6.560E-14 1.058E-13 2.365E-13 4.870E-18-1.000E+00 1.140E-09 6.570E-12 BONE SUR 9.580E-14 1.862E-13 4.162E-13 8.570E-18-1.000E+00 2.760E-09 6.460E-12 THYROID 6.780E-14 1.106E-13 2.472E-13 5.090E-18-1.000E+00 2.160E-10 2.860E-12 REMAINDER 6.410E-14 1.036E-13 2.316E-13 4.770E-18-1.000E+00 3.910E-09 6.130E-10 EFFECTIVE 6.750E-14 1.125E-13 2.515E-13 5.180E-18-1.000E+00 3.820E-09 1.870E-10 SKIN(FGR) 9.980E-14 1.173E-11 2.622E-11 5.400E-16-1.000E+00 0.000E+00 0.000E+00 La-143 GONADS 5.040E-15 4.689E-13 9.642E-12 1.630E-17-1.000E+00 6.530E-13 1.250E-10 BREAST 5.700E-15 5.150E-13 1.059E-11 1.790E-17-1.000E+00 3.200E-13 9.740E-11 LUNGS 5.070E-15 1.602E-13 3.295E-12 5.570E-18-1.000E+00 1.060E-10 9.620E-11 RED MARR 5.010E-15 1.249E-13 2.567E-12 4.340E-18-1.000E+00 7.300E-13 5.430E-09 BONE SUR 7.590E-15 9.005E-13 1.852E-11 3.130E-17-1.000E+00 7.290E-13 2.070E-08 THYROID 5.190E-15 2.779E-13 5.714E-12 9.660E-18-1.000E+00 2.440E-13 9.430E-11 REMAINDER 4.900E-15 1.999E-13 4.111E-12 6.950E-18-1.000E+00 1.050E-11 2.980E-09 EFFECTIVE 5.180E-15 3.251E-13 6.684E-12 1.130E-17-1.000E+00 1.620E-11 2.230E-09 SKIN(FGR) 9.640E-14 1.496E-12 3.076E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 Nb-97 GONADS 3.110E-14 3.889E-13 3.922E-13 6.510E-17-1.000E+00 8.650E-13 1.590E-12 BREAST 3.550E-14 3.800E-13 3.832E-13 6.360E-17-1.000E+00 1.120E-12 6.050E-13 LUNGS 3.100E-14 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.560E-10 4.910E-13 RED MARR 3.010E-14 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.140E-12 7.640E-13 BONE SUR 5.110E-14 5.753E-13 5.802E-13 9.630E-17-1.000E+00 8.260E-13 5.400E-13 THYROID 3.180E-14 3.525E-13 3.555E-13 5.900E-17-1.000E+00 9.200E-13 3.360E-13 REMAINDER 2.960E-14 3.262E-13 3.289E-13 5.460E-17-1.000E+00 1.050E-11 1.790E-10 EFFECTIVE 3.180E-14 3.590E-13 3.621E-13 6.010E-17-1.000E+00 2.240E-11 5.450E-11 SKIN(FGR) 6.510E-14 3.429E-11 3.458E-11 5.740E-15-1.000E+00 0.000E+00 0.000E+00 Nb-95m GONADS 2.880E-15 2.206E-12 4.799E-11 8.561E-17-1.000E+00 4.960E-11 2.420E-10 BREAST 3.310E-15 2.181E-12 4.739E-11 8.454E-17-1.000E+00 4.530E-11 1.664E-10 LUNGS 2.770E-15 1.741E-12 3.815E-11 6.808E-17-1.000E+00 3.070E-09 1.593E-10 RED MARR 2.590E-15 1.729E-12 3.793E-11 6.768E-17-1.000E+00 5.870E-11 3.500E-09 BONE SUR 6.600E-15 3.287E-12 7.147E-11 1.275E-16-1.000E+00 6.610E-11 7.990E-09 THYROID 2.890E-15 1.923E-12 4.201E-11 7.495E-17-1.000E+00 3.860E-11 1.572E-10
Numerical Applications Inc. Attachment 6 Page 131 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 REMAINDER 2.630E-15 1.746E-12 3.822E-11 6.819E-17-1.000E+00 8.690E-10 7.196E-09 EFFECTIVE 2.930E-15 1.974E-12 4.308E-11 7.686E-17-1.000E+00 6.590E-10 2.925E-09 SKIN(FGR) 1.120E-14 1.501E-10 3.360E-09 6.001E-15-1.000E+00 0.000E+00 0.000E+00 Pm-147 GONADS 7.480E-19 4.020E-11 2.343E-10 1.535E-15-1.000E+00 8.250E-15 7.415E-10 BREAST 9.560E-19 3.853E-11 2.246E-10 1.472E-15-1.000E+00 3.600E-14 1.361E-10 LUNGS 5.450E-19 3.657E-11 2.131E-10 1.397E-15-1.000E+00 7.740E-08 6.335E-11 RED MARR 4.460E-19 3.736E-11 2.178E-10 1.427E-15-1.000E+00 1.610E-09 2.435E-10 BONE SUR 2.180E-18 5.467E-11 3.189E-10 2.090E-15-1.000E+00 2.010E-08 3.248E-10 THYROID 6.750E-19 3.741E-11 2.181E-10 1.429E-15-1.000E+00 1.980E-14 4.383E-08 REMAINDER 5.260E-19 3.626E-11 2.113E-10 1.385E-15-1.000E+00 1.560E-09 3.153E-09 EFFECTIVE 6.930E-19 3.825E-11 2.229E-10 1.461E-15-1.000E+00 1.060E-08 2.514E-09 SKIN(FGR) 8.110E-16 1.033E-10 6.188E-10 4.056E-15-1.000E+00 0.000E+00 0.000E+00 Pm-148 GONADS 2.810E-14 6.812E-12 7.706E-11 2.450E-16-1.000E+00 2.120E-10 5.410E-10 BREAST 3.190E-14 6.756E-12 7.643E-11 2.430E-16-1.000E+00 7.190E-11 3.500E-10 LUNGS 2.830E-14 5.727E-12 6.479E-11 2.060E-16-1.000E+00 1.370E-08 3.300E-10 RED MARR 2.790E-14 5.588E-12 6.322E-11 2.010E-16-1.000E+00 1.070E-10 4.440E-10 BONE SUR 4.240E-14 1.273E-11 1.441E-10 4.580E-16-1.000E+00 7.080E-11 8.300E-10 THYROID 2.890E-14 5.978E-12 6.762E-11 2.150E-16-1.000E+00 3.820E-11 5.950E-08 REMAINDER 2.730E-14 5.644E-12 6.385E-11 2.030E-16-1.000E+00 4.100E-09 1.490E-09 EFFECTIVE 2.890E-14 6.339E-12 7.171E-11 2.280E-16-1.000E+00 2.950E-09 2.540E-09 SKIN(FGR) 7.970E-14 8.313E-12 9.405E-11 2.990E-16-1.000E+00 0.000E+00 0.000E+00 Pm-149 GONADS 5.300E-16 1.119E-11 1.789E-10 3.940E-16-1.000E+00 3.610E-12 4.070E-11 BREAST 6.070E-16 1.082E-11 1.730E-10 3.810E-16-1.000E+00 8.200E-13 1.210E-10 LUNGS 5.170E-16 1.016E-11 1.626E-10 3.580E-16-1.000E+00 3.120E-09 1.020E-10 RED MARR 4.890E-16 1.022E-11 1.635E-10 3.600E-16-1.000E+00 5.530E-12 9.440E-11 BONE SUR 1.100E-15 1.675E-11 2.679E-10 5.900E-16-1.000E+00 5.010E-12 8.720E-11 THYROID 5.360E-16 1.053E-11 1.685E-10 3.710E-16-1.000E+00 3.310E-13 4.760E-07 REMAINDER 4.910E-16 9.908E-12 1.585E-10 3.490E-16-1.000E+00 1.390E-09 1.570E-10 EFFECTIVE 5.410E-16 1.067E-11 1.707E-10 3.760E-16-1.000E+00 7.930E-10 1.440E-08 SKIN(FGR) 2.190E-14 1.825E-11 2.920E-10 6.430E-16-1.000E+00 0.000E+00 0.000E+00 Pm-151 GONADS 1.480E-14 2.523E-11 2.771E-11 2.320E-15-1.000E+00 7.170E-11 2.330E-11 BREAST 1.700E-14 2.414E-11 2.652E-11 2.220E-15-1.000E+00 1.590E-11 2.520E-11 LUNGS 1.440E-14 2.305E-11 2.532E-11 2.120E-15-1.000E+00 1.640E-09 2.640E-11 RED MARR 1.370E-14 2.360E-11 2.592E-11 2.170E-15-1.000E+00 2.720E-11 2.460E-11 BONE SUR 2.990E-14 3.327E-11 3.655E-11 3.060E-15-1.000E+00 1.860E-11 2.190E-11 THYROID 1.500E-14 2.381E-11 2.616E-11 2.190E-15-1.000E+00 6.180E-12 3.870E-09 REMAINDER 1.370E-14 2.283E-11 2.509E-11 2.100E-15-1.000E+00 8.390E-10 1.650E-10 EFFECTIVE 1.510E-14 2.403E-11 2.640E-11 2.210E-15-1.000E+00 4.730E-10 1.820E-10 SKIN(FGR) 3.320E-14 8.199E-11 9.007E-11 7.540E-15-1.000E+00 0.000E+00 0.000E+00 Pm-148m GONADS 9.470E-14 1.585E-11 6.748E-11 6.270E-16-1.000E+00 1.190E-09 3.630E-11 BREAST 1.080E-13 1.519E-11 6.468E-11 6.010E-16-1.000E+00 1.240E-09 4.680E-11 LUNGS 9.420E-14 1.446E-11 6.156E-11 5.720E-16-1.000E+00 3.590E-08 4.530E-11 RED MARR 9.140E-14 1.466E-11 6.242E-11 5.800E-16-1.000E+00 1.360E-09 4.300E-11 BONE SUR 1.580E-13 2.161E-11 9.202E-11 8.550E-16-1.000E+00 1.360E-09 4.070E-11 THYROID 9.680E-14 1.502E-11 6.393E-11 5.940E-16-1.000E+00 1.050E-09 9.100E-08 REMAINDER 9.010E-14 1.418E-11 6.038E-11 5.610E-16-1.000E+00 3.580E-09 1.550E-10 EFFECTIVE 9.680E-14 1.509E-11 6.425E-11 5.970E-16-1.000E+00 6.100E-09 2.800E-09 SKIN(FGR) 1.180E-13 1.150E-10 4.897E-10 4.550E-15-1.000E+00 0.000E+00 0.000E+00 Pr-144 GONADS 1.900E-15 1.200E-11 1.202E-11 2.640E-15-1.000E+00 2.410E-15 1.100E-11 BREAST 2.150E-15 1.145E-11 1.147E-11 2.520E-15-1.000E+00 1.050E-14 1.170E-11 LUNGS 1.900E-15 1.100E-11 1.102E-11 2.420E-15-1.000E+00 9.400E-11 1.260E-11 RED MARR 1.870E-15 1.127E-11 1.129E-11 2.480E-15-1.000E+00 1.380E-14 1.090E-11 BONE SUR 2.990E-15 1.568E-11 1.571E-11 3.450E-15-1.000E+00 1.470E-14 9.320E-12 THYROID 1.950E-15 1.127E-11 1.129E-11 2.480E-15-1.000E+00 8.470E-15 6.210E-10 REMAINDER 1.840E-15 1.091E-11 1.093E-11 2.400E-15-1.000E+00 1.400E-12 1.340E-10 EFFECTIVE 1.950E-15 1.150E-11 1.152E-11 2.530E-15-1.000E+00 1.170E-11 6.660E-11 SKIN(FGR) 8.430E-14 4.477E-11 4.485E-11 9.850E-15-1.000E+00 0.000E+00 0.000E+00 Pr-144m GONADS 3.250E-16 3.113E-11 5.489E-11 1.599E-15-1.000E+00 0.000E+00 3.610E-11 BREAST 4.200E-16 2.971E-11 5.240E-11 1.526E-15-1.000E+00 0.000E+00 3.850E-11 LUNGS 2.000E-16 2.886E-11 5.089E-11 1.482E-15-1.000E+00 0.000E+00 3.750E-11 RED MARR 1.560E-16 2.965E-11 5.228E-11 1.523E-15-1.000E+00 0.000E+00 3.650E-11 BONE SUR 8.160E-16 3.983E-11 7.024E-11 2.046E-15-1.000E+00 0.000E+00 3.360E-11 THYROID 2.810E-16 2.852E-11 5.030E-11 1.465E-15-1.000E+00 0.000E+00 1.790E-08 REMAINDER 1.980E-16 2.883E-11 5.084E-11 1.481E-15-1.000E+00 0.000E+00 1.540E-10 EFFECTIVE 2.790E-16 2.989E-11 5.271E-11 1.535E-15-1.000E+00 0.000E+00 6.080E-10 SKIN(FGR) 5.080E-16 9.826E-11 1.733E-10 5.047E-15-1.000E+00 0.000E+00 0.000E+00
Numerical Applications Inc. Attachment 6 Page 132 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 Sm-153 GONADS 2.330E-15 1.465E-12 2.052E-11 5.200E-17-1.000E+00 2.360E-11 0.000E+00 BREAST 2.820E-15 1.505E-12 2.107E-11 5.340E-17-1.000E+00 5.670E-12 0.000E+00 LUNGS 1.970E-15 1.045E-12 1.464E-11 3.710E-17-1.000E+00 2.050E-09 0.000E+00 RED MARR 1.620E-15 8.791E-13 1.231E-11 3.120E-17-1.000E+00 6.660E-11 0.000E+00 BONE SUR 7.290E-15 4.254E-12 5.958E-11 1.510E-16-1.000E+00 1.570E-10 0.000E+00 THYROID 2.220E-15 1.181E-12 1.653E-11 4.190E-17-1.000E+00 1.510E-12 0.000E+00 REMAINDER 1.850E-15 1.042E-12 1.460E-11 3.700E-17-1.000E+00 8.840E-10 0.000E+00 EFFECTIVE 2.280E-15 1.299E-12 1.819E-11 4.610E-17-1.000E+00 5.310E-10 0.000E+00 SKIN(FGR) 1.450E-14 1.953E-12 2.734E-11 6.930E-17-1.000E+00 0.000E+00 0.000E+00 Y-94 GONADS 5.490E-14 5.455E-12 1.194E-11 2.530E-16-1.000E+00 1.230E-13 0.000E+00 BREAST 6.210E-14 5.325E-12 1.166E-11 2.470E-16-1.000E+00 4.400E-13 0.000E+00 LUNGS 5.500E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 1.480E-10 0.000E+00 RED MARR 5.420E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 4.180E-13 0.000E+00 BONE SUR 8.220E-14 9.120E-12 1.997E-11 4.230E-16-1.000E+00 3.280E-13 0.000E+00 THYROID 5.650E-14 5.023E-12 1.100E-11 2.330E-16-1.000E+00 4.120E-13 0.000E+00 REMAINDER 5.300E-14 4.829E-12 1.058E-11 2.240E-16-1.000E+00 3.080E-12 0.000E+00 EFFECTIVE 5.620E-14 5.217E-12 1.142E-11 2.420E-16-1.000E+00 1.890E-11 0.000E+00 SKIN(FGR) 1.800E-13 4.506E-11 9.867E-11 2.090E-15-1.000E+00 0.000E+00 0.000E+00 Y-95 GONADS 4.650E-14 4.607E-11 9.646E-10 1.600E-15-1.000E+00 1.070E-13 2.060E-08 BREAST 5.190E-14 4.406E-11 9.224E-10 1.530E-15-1.000E+00 3.170E-13 1.720E-08 LUNGS 4.720E-14 4.204E-11 8.802E-10 1.460E-15-1.000E+00 8.040E-11 1.760E-08 RED MARR 4.730E-14 4.262E-11 8.922E-10 1.480E-15-1.000E+00 3.200E-13 1.870E-08 BONE SUR 6.410E-14 6.105E-11 1.278E-09 2.120E-15-1.000E+00 3.790E-13 1.740E-08 THYROID 4.840E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 2.790E-13 1.760E-08 REMAINDER 4.590E-14 4.147E-11 8.681E-10 1.440E-15-1.000E+00 1.250E-12 2.210E-08 EFFECTIVE 4.790E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.020E-11 1.980E-08 SKIN(FGR) 1.590E-13 6.249E-11 1.308E-09 2.170E-15-1.000E+00 0.000E+00 0.000E+00 Y-91m GONADS 2.490E-14 6.223E-11 1.102E-09 2.180E-15-1.000E+00 3.210E-13 3.040E-09 BREAST 2.850E-14 5.966E-11 1.056E-09 2.090E-15-1.000E+00 6.080E-13 2.650E-09 LUNGS 2.480E-14 5.710E-11 1.011E-09 2.000E-15-1.000E+00 7.000E-11 2.620E-09 RED MARR 2.390E-14 5.824E-11 1.031E-09 2.040E-15-1.000E+00 7.740E-13 2.950E-09 BONE SUR 4.280E-14 8.422E-11 1.491E-09 2.950E-15-1.000E+00 6.210E-13 2.710E-09 THYROID 2.540E-14 5.852E-11 1.036E-09 2.050E-15-1.000E+00 5.020E-13 2.740E-09 REMAINDER 2.370E-14 5.652E-11 1.001E-09 1.980E-15-1.000E+00 3.740E-12 3.520E-09 EFFECTIVE 2.550E-14 5.966E-11 1.056E-09 2.090E-15-1.000E+00 9.820E-12 3.040E-09 SKIN(FGR) 3.110E-14 7.251E-11 1.284E-09 2.540E-15-1.000E+00 0.000E+00 0.000E+00 Br-82 GONADS 1.270E-13 1.669E-11 3.530E-10 5.840E-16-1.000E+00 1.690E-10 1.390E-08 BREAST 1.440E-13 1.596E-11 3.376E-10 5.585E-16-1.000E+00 2.100E-10 1.240E-08 LUNGS 1.270E-13 1.517E-11 3.209E-10 5.309E-16-1.000E+00 1.680E-09 1.270E-08 RED MARR 1.240E-13 1.542E-11 3.260E-10 5.394E-16-1.000E+00 2.180E-10 1.320E-08 BONE SUR 1.990E-13 2.238E-11 4.734E-10 7.832E-16-1.000E+00 1.920E-10 1.260E-08 THYROID 1.300E-13 1.588E-11 3.358E-10 5.556E-16-1.000E+00 2.060E-10 1.260E-08 REMAINDER 1.220E-13 1.490E-11 3.152E-10 5.215E-16-1.000E+00 3.310E-10 1.450E-08 EFFECTIVE 1.300E-13 1.585E-11 3.353E-10 5.546E-16-1.000E+00 4.130E-10 1.350E-08 SKIN(FGR) 1.540E-13 5.253E-11 1.110E-09 1.836E-15-1.000E+00 0.000E+00 0.000E+00 Br-83 GONADS 3.740E-16 3.368E-13 3.429E-13 4.790E-17-1.000E+00 1.130E-12 1.560E-12 BREAST 4.290E-16 3.297E-13 3.357E-13 4.690E-17-1.000E+00 1.140E-12 5.170E-13 LUNGS 3.690E-16 3.002E-13 3.057E-13 4.270E-17-1.000E+00 1.820E-10 3.890E-13 RED MARR 3.540E-16 2.932E-13 2.985E-13 4.170E-17-1.000E+00 1.140E-12 8.590E-13 BONE SUR 6.750E-16 6.841E-13 6.965E-13 9.730E-17-1.000E+00 1.140E-12 4.380E-13 THYROID 3.800E-16 3.044E-13 3.100E-13 4.330E-17-1.000E+00 1.140E-12 2.660E-13 REMAINDER 3.520E-16 2.932E-13 2.985E-13 4.170E-17-1.000E+00 5.310E-12 3.570E-10 EFFECTIVE 3.820E-16 3.227E-13 3.286E-13 4.590E-17-1.000E+00 2.410E-11 1.080E-10 SKIN(FGR) 1.850E-14 7.241E-11 7.373E-11 1.030E-14-1.000E+00 0.000E+00 0.000E+00 Br-84 GONADS 9.160E-14 5.451E-12 9.607E-11 1.910E-16-1.000E+00 2.840E-12 9.960E-10 BREAST 1.020E-13 5.280E-12 9.305E-11 1.850E-16-1.000E+00 3.310E-12 1.590E-10 LUNGS 9.270E-14 4.852E-12 8.550E-11 1.700E-16-1.000E+00 1.560E-10 6.630E-11 RED MARR 9.260E-14 4.880E-12 8.601E-11 1.710E-16-1.000E+00 3.270E-12 4.390E-10 BONE SUR 1.280E-13 8.020E-12 1.413E-10 2.810E-16-1.000E+00 2.990E-12 5.530E-10 THYROID 9.500E-14 5.109E-12 9.003E-11 1.790E-16-1.000E+00 3.120E-12 5.250E-11 REMAINDER 8.990E-14 4.766E-12 8.399E-11 1.670E-16-1.000E+00 1.870E-11 7.370E-09 EFFECTIVE 9.410E-14 5.137E-12 9.053E-11 1.800E-16-1.000E+00 2.610E-11 2.560E-09 SKIN(FGR) 1.880E-13 5.565E-11 9.808E-10 1.950E-15-1.000E+00 0.000E+00 0.000E+00 Am-242 GONADS 6.090E-16 6.027E-11 4.425E-10 2.240E-15-1.000E+00 1.940E-09 1.340E-09 BREAST 7.300E-16 5.758E-11 4.228E-10 2.140E-15-1.000E+00 2.940E-12 1.800E-10
Numerical Applications Inc. Attachment 6 Page 133 of 133 Palisades Design Basis Small Line Break Outside Containment AST Radiological Analysis Calculation Number: NAI-1149-020 Rev. 0 LUNGS 5.510E-16 5.596E-11 4.109E-10 2.080E-15-1.000E+00 5.200E-08 4.010E-11 RED MARR 4.770E-16 5.731E-11 4.208E-10 2.130E-15-1.000E+00 1.320E-08 2.810E-10 BONE SUR 1.880E-15 7.776E-11 5.709E-10 2.890E-15-1.000E+00 1.650E-07 9.770E-11 THYROID 5.940E-16 5.462E-11 4.010E-10 2.030E-15-1.000E+00 2.520E-12 6.400E-12 REMAINDER 5.180E-16 5.569E-11 4.089E-10 2.070E-15-1.000E+00 8.540E-09 6.260E-09 EFFECTIVE 6.150E-16 5.812E-11 4.267E-10 2.160E-15-1.000E+00 1.580E-08 2.280E-09 SKIN(FGR) 8.200E-15 2.217E-10 1.628E-09 8.240E-15-1.000E+00 0.000E+00 0.000E+00 Np-238 GONADS 2.660E-14 7.315E-13 9.675E-13 4.740E-17-1.000E+00 1.990E-09 3.770E-12 BREAST 3.020E-14 7.007E-13 9.267E-13 4.540E-17-1.000E+00 4.180E-11 7.070E-13 LUNGS 2.650E-14 6.713E-13 8.879E-13 4.350E-17-1.000E+00 3.470E-09 2.720E-13 RED MARR 2.610E-14 6.852E-13 9.063E-13 4.440E-17-1.000E+00 1.690E-08 1.070E-12 BONE SUR 3.990E-14 9.923E-13 1.312E-12 6.430E-17-1.000E+00 2.100E-07 6.060E-13 THYROID 2.730E-14 6.590E-13 8.716E-13 4.270E-17-1.000E+00 2.450E-11 5.290E-14 REMAINDER 2.550E-14 6.682E-13 8.838E-13 4.330E-17-1.000E+00 2.550E-09 1.240E-09 EFFECTIVE 2.720E-14 7.007E-13 9.267E-13 4.540E-17-1.000E+00 1.000E-08 3.740E-10 SKIN(FGR) 4.310E-14 1.667E-10 2.204E-10 1.080E-14-1.000E+00 0.000E+00 0.000E+00 Pu-243 GONADS 1.020E-15 1.978E-11 2.034E-11 2.540E-15-1.000E+00 1.670E-12 6.990E-11 BREAST 1.210E-15 1.885E-11 1.938E-11 2.420E-15-1.000E+00 2.750E-13 1.540E-11 LUNGS 9.280E-16 1.846E-11 1.898E-11 2.370E-15-1.000E+00 2.270E-10 8.400E-12 RED MARR 7.840E-16 1.900E-11 1.954E-11 2.440E-15-1.000E+00 5.770E-12 1.930E-11 BONE SUR 3.230E-15 2.484E-11 2.554E-11 3.190E-15-1.000E+00 6.530E-11 7.400E-12 THYROID 9.910E-16 1.768E-11 1.818E-11 2.270E-15-1.000E+00 1.130E-13 1.160E-12 REMAINDER 8.660E-16 1.853E-11 1.906E-11 2.380E-15-1.000E+00 4.690E-11 5.200E-10 EFFECTIVE 1.030E-15 1.916E-11 1.970E-11 2.460E-15-1.000E+00 4.440E-11 1.790E-10 SKIN(FGR) 8.150E-15 9.111E-11 9.368E-11 1.170E-14-1.000E+00 0.000E+00 0.000E+00