UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555 EXELON GENERATION COMPANY, LLC DOCKET NO. 50-272 SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 FACILITY OPERATING LICENSE Amendment No.

License No. DPR-70

1.

The Nuclear Regulatory Commission (the Commission) having found that:

A.

The application for license complies with the standards and requirements of the Atomic Energy Act (the Act) of 1954, as amended, and the Commission's rules and regulations set forth in 10 CFR Chapter I and all required notifications to other agencies or bodies have been duly made; B.

Construction of the Salem Nuclear Generating Station, Unit No. 1 (facility) has been substantially completed in conformity with Provisional Construction Permit No. CPPR-52 and the application, as amended, the provisions of the Act and regulations of the Commission; C.

The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Commission; D.

There is reasonable assurance: (i) that the activities authorized by this amended operating license can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the rules and regulations of the Commission; E.

Exelon Generation Company, LLC (Exelon Generation Company) (the licensee) is technically qualified and the licensee is financially qualified to engage in the activities authorized by this amended operating license in accordance with the rules and regulations of the Commission; F.

The licensee has satisfied the applicable provisions of 10 CFR Part 140, wFinancial Protection Requirements and Indemnity Agreements,- of the Commission's regulations; G.

The issuance of this amended operating license will not be inimical to the common defense and security or to the health and safety of the public; H.

After weighing the environmental, economic, technical, and other benefits of the facility against environmental and other costs and considering available alternatives, the issuance of Amendment No. 3 to Facility Operating License No. DPR-70 subject to the conditions for protection of the environment set forth in the Technical Specifications, Appendix B is in accordance with 10 CFR Part 51 (and with former Appendix D to 10 CFR Part 50) of the Commission's regulations and all applicable requirements have been satisfied; and I.

The receipt, possession, and use of source, byproduct and special nuclear material as authorized by this amended license will be in accordance with the Commission's regulations in 10 CFR Parts 30, 40, and 70, including 10 CFR Sections 30.33, 40.32, and 70.23 and 70.31.

2.

Facility Operating License No. DPR-70, issued to Exelon Generation Company, LLC (Exelon Generation Company), (the licensee), is hereby amended in its entirety, to read as follows:

A.

This amended license applies to the Salem Nuclear Generating Station, Unit No. 1, a pressurized water nuclear reactor and associated equipment (the facility), owned and operated by Exelon Generation Company. The facility is located on the applicant's site in Salem County, New Jersey, on the southern end of Artificial Island on the east bank of the Delaware River in Lower Alloways Creek Township, and is described in the "Final Safety Analysis Report" as supplemented and amended (Amendments 10 through 39) and the Environmental Report as supplemented and amended (Amendments 1 through 3).

B.

Subject to the conditions and requirements incorporated herein, the Commission hereby licenses:

Amendment No.

(1)

Exelon Generation Company to possess the facility at the designated location in Salem County, New Jersey, in accordance with the procedures and limitations set forth in this amended license; (2)

Exelon Generation Company, pursuant to Section 104b of the Act and 10 CFR Part 50, "Licensing of Production and Utilization Facilities," to possess, use and operate the facility; (3)

Exelon Generation Company, pursuant to the Act and 10 CFR Part 70, to receive, possess and use at any time special nuclear material as reactor fuel, in accordance with the limitations for storage and amounts required for reactor operation, as described in the Final Safety Analysis Report, as supplemented and amended; (4)

Exelon Generation Company, pursuant to the Act and 10 CFR Parts 30, 40 and 70 to receive, possess and use at any time any byproduct, source and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5)

Exelon Generation Company, pursuant to the Act and 10 CFR Parts 30, 40 and 70 to receive, possess and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (6)

Exelon Generation Company, pursuant to the Act and 10 CFR Parts 30 and 70, to possess but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility.

C.

This amended license shall be deemed to contain and is subject to the conditions specified. in the following Commission regulations in 10 CFR.Chapter I: Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

Amendment No.

(1)

Maximum Power Level Exelon Generation Company is authorized to operate the facility at a steady state reactor core power level not in excess of 3459 megawatts (one hundred percent of rated core power).

(2)

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.

, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

(3)

Deleted Per Amendment 22, 11-20-79 (4)

Less than Four Loop Operation Exelon Generation Company shall not operate the reactor at power levels above P-7 (as defined in Table 3.3-1 of Specification 3.3.1.1 of Appendix A to this license) with less than four (4) reactor coolant loops in operation until safety analyses for less than four loop operation have been submitted by the licensees and approval for less than four loop operation at power levels above P-7 has been granted by the Commission by Amendment of this license.

(5)

Exelon Generation Company shall implement and maintain in effect all provisions of the approved fire protection program as described in the Updated Final Safety Analysis Report, and as approved in the NRC Safety Evaluation Report dated November 20, 1979, and in its supplements, subject to the following provision:

Exelon Generation Company may make changes to the approved fire protection program without prior approval of the Commission only if those changes would not adversely affect the ability to achieve and maintain safe shutdown in the event of a fire.

Amendment No.

4b -

(10)

Additional Conditions The Additional Conditions contained in Appendix C, as revised through Amendment No.

, are hereby incorporated into this license.

Exelon Generation Company shall operate I the facility in accordance with the Additional Conditions.

(11)

DELETED I

Amendment No.

4c -

(12)

Exelon Generation Company shall provide to the Director of the Office of Nuclear Reactor Regulation a copy of any application, at the time it is filed, to transfer (excluding grants of security interests or liens) from Exelon Generation Company to its direct or indirect parent, or to any other affiliated company, facilities for the production, transmission, or distribution of electric energy having a depreciated book value exceeding ten percent (10%) of Exelon Generation Company's consolidated net utility plant, as recorded on Exelon Generation Company's books of account.

(13)

At the time of the closing of the transfer of this license from PSEG Nuclear LLC, to Exelon Generation Company, PSEG Nuclear LLC shall transfer to Exelon Generation Company all of PSEG Nuclear LLC's decommissioning funds for Salem Nuclear Generating Station, Unit No.1 accumulated as of such time, and Exelon Generation Company shall deposit such funds in an external decommissioning trust established by Exelon Generation Company for Salem Nuclear Generating Station, Unit No.1.

(14)

DELETED (15)

DELETED Amendment No.

D.

Paragraph 2.D. has been combined with paragraph 2.E. per Amendment No. 86, June 27, 1988.

E.

The licensee shall fully implement and maintain in effect all.

provisions of the Commission-approved physical security, guard training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 10 CFR 50.54(p).

The plans, which contain Safeguards Information protected under 10 CFR 73.21, are entitled:

'Salem-Hope Creek Nuclear Generating Station Security Plan," with revisions submitted through December 17, 2001; "Salem-Hope Creek Nuclear Generating Station Security Training and Qualification Plan," with revisions submitted through December 17, 2001; and

'Salem-Hope Creek Nuclear Generating Station Security Contingency Plan,- with revisions submitted through June 2, 1998.

Changes made in accordance with 10 CFR 73.55 shall be implemented in accordance with the schedule set forth therein.

F.

In accordance with the requirement imposed by the October 8, 1976, order of the United States Court of Appeals for the District of Columbia Circuit in Natural Resources Defense Council

v. Nuclear Regulatory Commission, No. 74-1385 and 74-1586, that the Nuclear Regulatory Commission "shall make any licenses granted between July 21, 1976 and such time when the mandate is issued subject to the outcome of the proceedings herein,, the license amendment issued herein shall be subject to the outcome of such proceedings.

G.

Prior to startup following the first regularly scheduled refueling outage, Public Service Electric and Gas Company shall install, to the satisfaction of the Commission, a long-term means of protection against reactor coolant system over-pressurization when water-solid.

H.

This amended license is effective as of the date of its issuance.

Facility Operating License No. DPR-70, as amended, shall expire at midnight, August 13, 2016.

I.

IAEA SAFEGUARDS

1.

INCORPORATION OF.FACILITY ATTACHMENT:

Pursuant to 10 CFR 75.8, NRC License No. DPR-70 is hereby amended to incorporate by reference Codes 1. through 7. of Facility Attachment No. 13 dated October 1, 1986, to the US/IAEA of Safeguards Agreement.

Amendment No.

5a -

2.

FACILITY ATTACHMENT CODE 2.2 Notification of the changes referred to in Code 2.2 of the facility attachment is the responsibility of the operating facility.

They can be notified to the NRC with a Concise Note (DOE/NRC Form 740M) or a letter.

Notification is required 70 days prior to the event.

3.

FACILITY ATTACHMENT CODE 3.1.3 & 5.1.2 & 5.2.3 The itemized lists of nuclear material to be provided to the IAEA as of cycle shutdown date prior to physical inventory taking are:

1.

A complete list of fuel assemblies by ID number at all locations.

2.

Reactor and fuel storage maps showing location of fuel by ID number at time of physical inventory taking.

3.

A list, by batch, of any other accountable nuclear material, e.g., start-up sources, samples.

4.

FACILITY ATTACHMENT CODE 3.2.2 Please refer to NRC letter dated May 27, 1986, to Mr. C.A.

McNeill from Steven A. Varga which spells out timeliness and procedures for notification under this code.

5.

FACILITY ATTACHMENT CODE 5.1.1 & 6.1.1 The statement "when calculated" means at least as often as required on page 2 of NUREG/BR-0006 Revision 2 or more often, at your option, if you calculate burn up more than every six months.

6.

FACILITY ATTACHMENT CODE 6.1.1 & 6.1.2 The phrase "as specified in relevant paragraphs of Code 10" is a requirement on the U.S.

All of the paragraphs in the US/IAEA Agreement that require a report from the U.S. to the IAEA based on source data from an operating facility have been incorporated into NUREG's BR-0006 and 0007 so that the NRC may collect the needed data for transmittal to the IAEA.

Exelon Generation Company should follow these NUREGs precisely in reporting inventory changes.

A complete response to the reporting instructions in the NUREGs will satisfy the requirements specified in Code 10.

Amendment No.

5c -

10.

TERMINATION Pursuant to the provisions of 10 CFR 75.41, the Commission will inform the licensee, in writing, when its installation is no longer subject to Article 39(b) of the principal text of the US/IAEA Safeguards Agreement.

The IAEA Safeguards License Conditions incorporating Code 7. of the Facility Attachment as part of NRC License DPR-70 will be terminated as of the date of such notice from the Commission.

However, since the IAEA may elect to maintain the licensee's installation under Article 2(a) of the Protocol, provisions equivalent to Codes 1. through 6. of the Facility Attachment (with possible appropriate modifications) may still apply, and accordingly all other IAEA Safeguards License Conditions to NRC License No. DPR-70 will remain in effect until the Commission notifies the licensee otherwise.

If this option is not selected by the IAEA, the Commission will then notify the licensee that all License Conditions pertaining to the US/IAEA Safeguards Agreement are terminated.

J.

RELOCATED TECHNICAL SPECIFICATIONS Exelon Generation Company shall relocate certain technical specification requirements to licensee-controlled documents as described below. The location of these requirements shall be retained by the licensee.

a.

This license condition approves the relocation of certain technical specification requirements to licensee-controlled documents (UFSAR), as described in the licensee's applications with the staff's safety evaluation approval and Amendment No. as noted below:

Licensee's Applications Safety Evaluations Amendment Nos.

September 25, 1996 January 30, 1997 189 Implementation shall include the relocation of technical specifications requirements to the appropriate licensee-controlled document as identified in the licensee's application.

FOR THE NUCLEAR REGULATORY COMMISSION Original Signed by Roger S. Boyd Roger S. Boyd, Director Division of Project Management Office of Nuclear Reactor Regulation Attachments:

1.

Incomplete Preoperational Tests, Startup Tests, and Other Items Which Must Be Completed

2.

Page Changes to Technical Specifications, Appendix A Date of Issuance: December 1, 1976 Amendment No.

DEFINITIONS

b.

Leakage into the containment atmosphere from sources that are both specifically located and known either not to interfere with the operation of leakage detection systems or not to be PRESSURE BOUNDARY LEAKAGE, or

c.

Reactor coolant system leakage through a steam generator to the secondary system (primary-to-secondary leakage).

MEMBER(S) OF THE PUBLIC 1.16 MEMBER(S) OF THE PUBLIC shall be all those persons who are not occupationally associated with the plant.

This category does not include employees of Exelon Generation Company, LLC, its contractors, or vendors.

Also excluded from this category are persons who enter the site to service equipment or to make deliveries.

This category does include persons who use portions of the site for recreational, occupational, or other purposes not associated with the plant.

OFFSITE DOSE CALCULATION MANUAL (ODCM) 1.17 The OFFSITE DOSE CALCULATION MANUAL (ODCM) shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring Alarm/Trip setpoints, and in the conduct of the Environmental Radiological Monitoring Program. The ODCM shall also contain (1) the Radioactive Effluent controls and Radiological Environmental Monitoring programs required by Section 6.8.4 and (2) descriptions of the information that should be included in the Annual Radiological Environmental Operating and Annual Radioactive Effluent Release Reports required by Specifications 6.9.1.7 and 6.9.1.8 respectively.

OPERABLE - OPERABILITY 1.18 A system, subsystem, train, component, or device shall be OPERABLE or have OPERABILITY when it is capable of performing its specified safety function(s) and when all necessary attendant instrumentation, controls, normal or emergency electrical power, cooling and seal water, lubrication, and other auxiliary equipment that are required for the system, subsystem, train, component, or device to perform its specified safety function(s) are also capable of performing their related support function(s).

OPERATIONAL MODE -

MODE 1.19 An OPERATIONAL MODE (i.e., MODE) shall correspond to any one inclusive combination of core reactivity condition, power level and average reactor coolant temperature specified in Table 1.1.

SALEM -

UNIT 1 1-4 Amendment No.

3/4.9 REFUELING OPERATIONS BASES The minimum requirement for reactor subcriticality also ensures that the decay time is consistent with that assumed in the Spent Fuel Pool cooling analysis. Delaware River water average temperature between October 15th and May 15th is determined from historical data taken over 30 years.

The use of 30 years of data to select maximum temperature is consistent with Reg. Guide 1.27, "Ultimate Heat Sink for Nuclear Power Plants'.

A core offload has the potential to occur during both applicability time frames.

In order not to exceed the analyzed Spent Fuel Pool cooling capability to maintain the water temperature below 1800F, two decay time limits are provided.

In addition, Exelon Generation Company, LLC has developed and implemented a Spent Fuel Pool Integrated Decay Heat Management Program as part of the Salem Outage Risk Assessment. This program requires a pre-outage assessment of the Spent Fuel Pool heat loads and heatup rates to assure available Spent Fuel Pool cooling capability prior to offloading fuel.

3/4.9.4 CONTAINMENT BUILDING PENETRATIONS During movement of irradiated fuel assemblies within containment the requirements for containment building penetration closure capability and OPERABILITY ensure that a release of fission product radioactivity within containment will not exceed the guidelines and dose calculations described in Reg. Guide 1.183, Alternative Radiological Source Term for Evaluating Design Basis Accidents at Nuclear Power Reactors.

In MODE 6, the potential for containment pressurization as a result of an accident is not likely.

Therefore, the requirements to isolate the containment from the outside atmosphere can be less stringent.

The LCO requirements during movement of irradiated fuel assemblies within containment are referred to as containment closure, rather than containment OPERABILITY. For the containment to be OPERABLE, CONTAINMENT INTEGRITY must be maintained.

Containment closure means that all potential containment atmosphere release paths are closed or capable of being closed.

Closure restrictions include the administrative controls to allow the opening of both airlock doors and the equipment hatch during fuel movement provided that: 1) the equipment inside door or an equivalent closure device installed is capable of being closed with four bolts within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> by a designated personnel; 2) the airlock door is capable of 'being closed within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> by a designated personnel, 3) either the Containment Purge System or the Auxiliary Building Ventilation System taking suction from the containment atmosphere are operating and 4) the plant is in Mode 6 with at least 23 feet of water above the reactor pressure vessel flange.

Administrative requirements are established for the responsibilities and appropriate actions of the designated personnel in the event of a Fuel Handling Accident inside containment.

These requirements include the responsibility to be able to communicate with the control room, to ensure that the equipment hatch is capable of being closed, and to close the equipment hatch and personnel airlocks within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> in the event of a fuel handling accident inside containment.

These administrative controls ensure containment closure will be established in accordance with and not to exceed the dose calculations performed using guidelines of Regulatory Guide 1.183.

SALEM - UNIT 1 B 3/4 9-Ic-Amnwmdment No.

ADMINISTRATIVE CONTROLS

c.

A detailed description of the equipment, components and processes involved and the interfaces with other plant systems;

d.

An evaluation of the change, which shows the predicted releases of radioactive materials in liquid and gaseous effluents and/or quantity of solid waste that differ from those previously predicted in the license application and amendments thereto;

e.

An evaluation of the change, which shows the expected maximum exposures to individual in the unrestricted area and to the general population that differ from those previously estimated in the license application and amendments thereto;

f.

A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents and in solid waste, to the actual releases for the period prior to when the changes are to be made;

g.

An estimate of the exposure to plant operating personnel as a result of the change; and

h.

Documentation of the fact that the change was reviewed and found acceptable by the (SORC).

2.

Shall become effective upon review and acceptance by the SORC.

6.16 ENVIRONMENTAL QUALIFICATION 6.16.1 All safety-related electrical equipment in the facility shall be qualified in accordance with the provisions of:

Division of Operating Reactors "Guidelines for Evaluating Environmental Qualification of Class lE Electrical Equipment in Operating Reactors (DOR Guidelines); or, NUREG-0588 "Interim Staff Position on Environmental Qualification of Safety-Related Electrical Equipment, " December 1979.

Copies of these documents are attached to Order for Modification of License No. DPR-70 dated October 24, 1980.

6.16.2 Complete and auditable records shall be available and maintained at a central location which describe the environmental qualification method used for all safety related electrical equipment in sufficient detail to document the degree of compliance with the DOR Guidelines or NUREG-0588.

Such records should be updated and maintained current as equipment is replaced, further tested, or otherwise further qualified.

6.17 TECHNICAL SPECIFICATION (TS) BASES CONTROL PROGRAM This program provides a means for processing changes to the Bases of these Technical Specifications.

a.

Changes to the Bases of the TS shall be made under appropriate administrative controls and reviews.

SALEM - UNIT 1 6-30 Amendment No.

ADMINISTRATIVE CONTROLS

b.

Exelon Generation Company, LLC may make changes to the Bases without prior NRC approval provided the changes do not require either of the following:

1. A change in the TS incorporated in the License, or
2. A change to the updated FSAR or Bases that requires NRC approval pursuant to 10 CFR 50.59.
c.

Proposed changes to the Bases that require either condition of Specification 6.17.b above shall be reviewed and approved by the NRC prior to implementation.

d.

Changes to the Bases implemented without prior NRC approval shall be provided to the NRC on a frequency consistent with 10 CFR 50.71(e).

e.

The Bases Control Program shall contain provisions to ensure that the Bases are maintained consistent with the UFSAR.

SALEM - UNIT 1 6-31 Amendment No.

APPENDIX B TO FACILITY OPERATING LICENSE NO. DPR-70 SALEM GENERATING STATION UNIT 1 DOCKET NO. 50-272 AND FACILITY OPERATING LICENSE NO. DPR-75 SALEM GENERATING STATION UNIT 2 DOCKET NO. 50-311 EXELON GENERATION COMPANY, LLC ENVIRONMENTAL PROTECTION PLAN (NONRADIOLOGICAL)

Amendment No.

4.0 Environmental Conditions 4.1 Unusual or Important Environmental Events Any occurrence of an unusual or important event that indicates or could result in significant environmental impact causally related to plant operation shall be recorded and reported to the NRC within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> followed by a written report per Subsection 5.4.2. The following are examples:

excessive bird impaction events; onsite plant or animal disease outbreaks; mortality or unusual occurrence of any species protected by the Endangered Species Act of 1973; fish kills or impingement events on the intake screens; increase in nuisance organisms or conditions; unanticipated or emergency discharge of waste water or chemical substances.

No routine monitoring programs are required to implement this condition.

4.2 Environmental Monitoring 4.2.1 Aquatic Monitoring The certifications and permits requited under the Clean Water Act provide mechanisms for protecting water quality and, indirectly, aquatic biota.

The Nuclear Regulatory Commission (NRC) will rely on the decisions made by the State of New Jersey under the authority of the Clean Water Act and, in the case of sea turtles and shortnose sturgeon, decisions made by the National Marine Fisheries Service (NMFS) under the authority of the Endangered Species Act, for any requirements pertaining to aquatic monitoring.

In accordance with Section 7(a) of the Endangered Species Act, on May 14, 1993. the National Marine Fisheries Service issued a Section 7 Consultation Biological Opinion related to the operation of Salem Unit 1 and 2 Generating Stations.

This Section 7 Consultation entitled, "Reinitiation of a consultation in accordance with Section 7(a) of the Endangered Species Act regarding continued operation of the Salem and Hope Creek Nuclear Generating Stations on the eastern shore of the Delaware River in New Jersey,w concluded that

....continued operation is not likely to jeopardize the continued existence of listed species."

Exelon Generation Company, LLC shall adhere to the specific requirements within the Incidental Take Statement, to the Biological Opinion.

Changes to the incidental take statement must be proceeded by consultation between the NRC, as the authorizing agency, and NMFS.

The Conservation Recommendation, to the Biological Opinion suggests conservation recommendations for implementation by Salem Generating Station.

The Station shall implement these recommendations to the satisfaction of the NRC and National Marine Fisheries Service.

SALEM UNIT 1 4-1 Amendment No.

APPENDIX C ADDITIONAL CONDITIONS OPERATING LICENSE NO. DPR-70 Exelon Generation Company, LLC shall comply with the following conditions on the schedules noted below:

I Amendment Number Additional Condition Implementation Date 192 194 196 The licensee is authorized to relocate certain Technical Specification requirements to licensee-controlled documents. Implementation of this amendment shall include the relocation of these technical specification requirements to the appropriate documents, as described in the licensee's application dated January 11, 1996, as supplemented by letters dated February 26, May 22, June 27, July 12, December 23, 1996, and March 17, 1997, and evaluated in the staff's safety evaluation attached to this amendment.

The licensee is authorized to upgrade the initiation circuitry for the power operated relief valves, as described in the licensee's application dated January 31, 1997, as supplemented by letters dated March 14, April 8, and April 28, 1997, and evaluated in the staffIs safety evaluation attached to this amendment.

The licensee shall complete all modifications associated with the amendment request concerning Containment Fan Cooler Units (CFCU) response time dated October 25, 1996, as described in the letters supplementing the amendment request dated December 11, 1996, January 28, March 27, April 24, June 3, and June 12, 1997, prior to entry into Mode 3 following refueling outage 12. All modifications made in support of this amendment request and described in the referenced submittals shall be in conformance with the existing design basis for Salem Unit 1, and programmatic controls for tank monitoring instrumentation shall be as described in the letter dated April 24, 1997. Post modification testing and confirmatory analyses shall be as described in the letter dated March 27, 1997.

Future changes to the design described in these submittals may be made in accordance with the provisions of 10 CFR 50.59.

Further, the administrative controls associated with CFCU operability and containment integrity described in the letters dated March 27, and April 24, 1997 shall not be relaxed or changed without prior staff review until such time as the license has been amended to include the administrative controls as technical specification requirements.

The licensee shall perform an evaluation of the containment liner anchorage by November 30, 1997, for the loading induced on the contianment liner during a Main Steam Line Break event to confirm the assumptions provided in the Preliminary Safety Analysis Report and Updated Final Safety Analysis Report.

The amendment shall be implemented within 60 days from March 21, 1997.

The amendment shall be implemented prior to entry into Mode 3 from the current outage for Salem Unit 1.

The amendment shall be implemented prior to entry into Mode 3 from the current outage for Salem Unit 1.

The amendment shall be implemented within 30 days from July 17, 1997.

198 1

Amendment No.