ENCLOSURE (1)
NINE MILE POINT NUCLEAR STATION, UNIT 1 RADIOACTIVE EFFLUENT RELEASE REPORT January 1, 2005 - December 31, 2005 Facility Operating License DPR-63 Docket No. 50-220 Nine Mile Point Nuclear Station, LLC May 01, 2006
NINE MILE POINT NUCLEAR STATION - UNIT I RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2005 Constellation Energy Nine Mile Point Nuclear Station
Page 1 of 2 NINE MILE POINT NUCLEAR STATION - UNIT I RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2005 SUPPLEMENTAL INFORMATION Facility: Nine Mile Point Unit #1 Licensee:
Nine Mile Point Nuclear Station, LLC
- 1.
TECHNICAL SPECIFICATION LIMITS A)
FISSION AND ACTIVATION GASES
- 1. The dose rate limit of noble gases released in gaseous effluents from the site to areas at or beyond the site boundary shall be less than or equal to 500 mrems/year to the whole body and less than or equal to 3000 mrems/year to the skin.
- 2.
The air dose due to noble gases released in gaseous effluents from Nine Mile Point Unit 1 to areas beyond the site boundary shall be limited during any calendar quarter to less than or equal to 5 milliroentgen for gamma radiation and less than or equal to 10 mrads for beta radiation, and during any calendar year to less than or equal to 10 milliroentgen for gamma radiation and less than or equal to 20 mrads for beta radiation.
B&C) TRITIUM, IODINES AND PARTICULATES, HALF LIVES > 8 DAYS
- 1. The dose rate limit of lodine-131, lodine-133, Tritium and all radionuclides in particulate form with half-lives greater than eight days, released in gaseous effluents from the site to areas at or beyond the site boundary shall be less than or equal to 1500 mrems/year to any organ.
- 2.
The dose to a member of the public from lodine-1 31, lodine-1 33, Tritium and all radionuclides in particulate form with half-lives greater than eight days in gaseous effluents released from Nine Mile Point Unit 1 to areas beyond the site boundary shall be limited during any calendar quarter to less than or equal to 7.5 mrems to any organ and, during any calendar year to less than or equal to 15 mrems to any organ.
D)
LIQUID EFFLUENTS
- 1. The concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to ten times the concentrations specified in 10 CFR Part 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-04 microcuries/ml total activity.
- 2.
The dose or dose commitment to a member of the public from radioactive materials in liquid effluents released from Nine Mile Point Unit 1 to unrestricted areas shall be limited during any calendar quarter to less than or equal to 1.5 mrems to the total body and to less than or equal to 5 mrems to any organ, and during any calendar year to less than or equal to 3 mrems to the total body and to less than or equal to 10 mrems to any organ.
Page 2 of 2
- 2.
MEASUREMENTS AND APPROXIMATIONS OF TOTAL RADIOACTIVITY Described below are the methods used to measure or approximate the total radioactivity and radionuclide composition in effluents.
A)
FISSION AND ACTIVATION GASES Noble gas effluent activity is determined by gross activity monitoring (calibrated against gamma isotopic analysis of a 4.OL Marinelli grab sample) of an isokinetic stack sample stream.
B)
IODINES Iodine effluent activity is determined by gamma spectroscopic analysis (at least weekly) of charcoal cartridges sampled from an isokinetic stack sample stream.
C)
PARTICULATES Activity released from the main stack is determined by gamma spectroscopic analysis (at least weekly) of particulate filters sampled from an isokinetic sample stream and composite analysis of the filters for non-gamma emitters.
D)
TRITIUM Tritium effluent activity is measured by liquid scintillation or gas proportional counting of monthly samples taken with an air sparging/water trap apparatus. Tritium effluent activity is measured during purge and weekly when fuel is offloaded until stable tritium release rates are demonstrated.
E)
EMERGENCY CONDENSER VENT EFFLUENTS The effluent curie quantities are estimated based on the isotopic distribution in the Condensate Storage Tank water and the Emergency Condenser shell water. Actual isotopic concentrations are found via gamma spectroscopy. Initial release rates of Sr-89, Sr-90 and Fe-55 are estimated by applying scaling factors to release rates of gamma emitters and actual release rates are determined from post offsite analysis results. The activity of fission and activation gases released due to tube leaks is based on reactor steam leak rates using offgas isotopic analyses.
F)
LIQUID EFFLUENTS Isotopic contents of liquid effluents are determined by isotopic analysis of a representative sample of each batch and composite analysis of non-gamma emitters. Tritium activity is estimated on the most recent analysis of the Condensate Storage Tank water. Initial release rates of Sr-89, Sr-90, and Fe-55 are estimated by applying scaling factors to release rates of gamma emitters and actual release rates are determined from post offsite analysis results.
G)
SOLID EFFLUENTS Isotopic contents of waste shipments are determined by gamma spectroscopy analysis of a representative sample of each batch. Scaling factors established from primary composite sample analyses conducted off-site are applied, where appropriate, to find estimated concentration of non-gamma emitters. For low activity trash shipments, curie content is estimated by dose rate measurement and application of appropriate scaling factors.
Attachment I Page 1 of 2 Unit I X
Unit 2 Reporting Period January -December 2005 Liquid Effluents:
ODCM Required MEC = 10 x 10CFR20, Appendix B, Table 2, Column 2 There were no discharges of liquid radwaste requiring use of MEC to determine allowable release rate.
There were no Emergency Condenser Vent Liquid Discharges in 2005 Average MEC - pCiml (Qtr. ) =
NO RELEASES Average MEC - pCi/ml (Qtr. a) =
RELEASES l Average MEC - pC/ml (Qtr.=
NO RELEASES Average MEC - pCi/ml (Qtr. J =NO RELEASES Average Energy (Fission and Activation gases - MeV):
Qrtr. 1:
Ey
=
2.47E-01 E13
=
3.17E-01 Qrtr. 2:
Ey
=
N/A EP
=
NWA Qrtr. 3:
EY
=
2.47E-01 E1
=
3.17E-01 Qrtr. 4:
EY
=
2.47E-01 Ep
=
3.17E-01 Liquid:
Radwaste EC Vent Numbr of Batch Releases 0
0 Total Time Period for Batch Releases (hrs)
N/A N/A Maximum Time Period for a Batch Release (hrs)
N/A N/A Average Time Period for a Batch Release (hrs)
N/A Minimum Time Period for a Batch Release (hrs)
N/A Total volume of water used to dilute 1st 2nd 3rd 4th the liquid effluent during release period (L)
N/A N/A N/A N/A Total volume of water used to dilute s
2nd 3rd 4th the liquid effluent during report period (L)
N/A N/A N/A N/A Gaseous(Emergency Condenser Vent):
Numbr of Batch Releases 0
Total Time Period for Batch Releases (hrs)
N/A Maximum Time Period for a Batch Release (hrs)
NIA Average Time Period for a Batch Release (hrs)
N/A Minimum Time Period for a Batch Release (hrs)
N/A Gaseous (Primary Containment Purge):
Numbr of Batch Releases I
Total Time Period for Batch Releases (hrs) 13.1 Maximum Time Period for a Batch Release (hrs) 13.1 Average Time Period for a Batch Release (hrs) 13.1 Minimum lime Period for a Batch Release (hrs) 13.1
Attachment I Page 2 of 2 Unit I X
Unit 2 Reorting Period January - December 2005 Abnormal Releases:
A Liquids:
Number of Releases 0
ITotal Activity Released NIA Ci B. Gaseous:
Numberof Releases 0
Total Activity Released N/A Ci Page 1 of 1 Unit I X
Unit 2 Reporting Period January-December 2005 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES, ELEVATED AND GROUND LEVEL 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter EST. TOTAL ERROR. %
A. Fission & Activation Gases (1)
- 1. Total Release
- 2.
Average Release Rate B. lodines (1)
- 1.
Total Iodine -131
- 2.
Average Release Rate for Period C. Particulates (1)
- 1. Particulates with half-lives>8 days
- 2.
Average Release Rate for Period
- 3. Gross alpha radioactivity D. Tritium (1)
- 1. Total release
- 2.
Average Release Rate for Period E. Percent of Tech. Soec. Limits Fission and Activation Gases Percent of Quarterly Gamma Air Dose Limit (5 mR)
Percent of Quarterly Beta Air Dose Limit (10 mrad)
Percent of Annual Gamma Air Dose Limit to Date (10 mR)
Percent of Annual Beta Air Dose Limit to Date (20 mrad)
Percent of Whole Body Dose Rate Limit (500 mremlyr)
Percent of Skin Dose Rate Limit (3000 mremlyr)
Tritium. lodines. and Particulates (with half-lives greater than 8 days)
Percent of Quarterly Dose Limit (7.5 mrem)
Percent of Annual Dose Limit to Date (15 mrem)
Percent of Organ Dose Limit (1500 mrem/yr Ci pCi/sec Ci pCi/sec Ci pCl/sec Ci Ci pCVsec 3.28E-05 6.35E.O1 1.01 E.05 4.22E-06 7.99E-02 1.27E-06 6.37E-04 1.OSE-04 2.52E-04 2.64E-04 I8.09E-05 I1.34E-05 I3.18E-05 I3.34E-05 I7.64E-04 1
1.95E2-03 I4.34E-04 6.56E-04 9.72E-05 2.47E-04 5.49E-05 7.04E-05 3.49E-05 7.24E-05 7.22E-05 4.37E-05 1.01IE+011 9.23E+00 1.SOE+01 1.291El:::
1.28E+00 1.17E+00 2.A0E+00 1.63E+00 2.64E-07 0.OOE+00 2.90E-03 8.14E-08 1.70E-07 0.OOE2+00 1.19E-03 5.20E-08 1.32E-07 1.32E-07 1.45E.03 1.45E-03 8.50E-08 8.50E-08 5.9SE-04 5.95E-04 7.06E-09 0.OOE2+00 7.64E-05 2.12E-09 3.12E-09 0.OOE2+00 2.68E-05 9.37E-110 2.58E2-01 1.04E-01 1.18E-01 8.03E-02 1.30E.C01 1.53E-01 2.43E-01 2.83E-01 6.24E-03, 2.09E-03 2.35E-03 1.59E.03 5.OOE+01 3.OOE+01 3.OOE+01 2.50E+01 5.OOE+01 (1) Concentrations less than the lower limit of detection of the counting system used are indicated with a double asterisk.
Page 1 of 1 Unit 1 X
Unit 2 Reporting Period January -December 2005 GASEOUS EFFLUENTS - ELEVATED RELEASE Continuous Mode (2)
Nuclides Released 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Fission Gases (1)
Argon-41 Krypton-85 Krypton-85m Krypton-87 Krypton-88 Xenon-127 Xenon-131m Xenon-133 Xenon-I 33m Xenon-135 Xenon-1 35m Xenon-137 Xenon-138 lodines (1)
Iodine-131 Iodine-133 Iodine-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Particulates (1)
Strontium-89 Strontium-90 Cesium-134 Cesium-137 Cobalt-60 Cobalt-58 Manganese-54 Barium-140 Lanthanum-140 Niobium-95 Cerium-141 Cerium-144 Iron-59 Cesium-136 Chromium-51 Zinc-65 Iron-55 Molybdenum-99 Neodymium-147 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci ci Ci 6.35E-01
- a*
6.37E-04 1.05E-04 2.52E-04 l
2.64E-04 1.69E-03 2.46E-05 6.93E-04 5.13E-04 8.95E-06 3.48E-06 3.72E-06 6.03E-04 1.34E-03 4.31E-04 5.12E-04 2.46E-05 4.45E-05 1.51 E-05 8.38E-05 1.88E-04 2.52E-05 4.38E-05 1.67E-04 2.06E-04 7.95E+00 6.93E+00 1.56E+01 1.14E+01 Tritium (1)
Ci (1) Concentrations less than the lower limit of detection of the counting system used are indicated with a double asterisk "
A lower limit of detection of 1.OOE-04 pCiml for required noble gases, 1.OOE-1I pCiml for required particulates, 1.OOE-12 pCi/ml for required lodines, and 1.OOE-06 pCi/ml for Tritium as required by the ODCM, has been verified.
(2) Contributions from purges are included. There were no other batch releases during the reporting period.
Page 1 of 1 Unit 1 X
Unit 2 Reporting Period January - December 2005 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Ground level releases are determined in accordance with the Off-Site Dose Calculation Manual and Chemistry procedures.
Continuous Mode Nuclides Released 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Fission Gases (1)
Argon-41 Krypton-85 Krypton-85m Krypton-87 Krypton-88 Xenon-127 Xenon-131m Xenon-133 Xenon-133m Xenon-135 Xenon-135m Xenon-137 Xenon-1 38 Ci Ci Ci Ci Ci Ci Ci C
C Ci Ci Ci Ci lodines (1)
Iodine-131 Iodine-133 Iodine-1i35 Ci Ci c
Particulates (1)
Strontium-89 Strontium-90 Cesium-134 Cesium-1i37 Cobalt-60 Cobalt-58 Manganese-54 Barium-140 Lanthanum-140 Niobium-95 Cerium-141 Cerium-144 Iron-59 Cesium-136 Chromium-51 Zinc-65 Iron-55 Molybdenum-99 Neodymium-147 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci c
Ci Ci Ci Ci Ci 3.28E-05 1.39E-05 1.01 E-05 at I
It T 1
- a at a
l2.1 5E+00O 2.29E+00O 3.37E+00 1
1.46E+00Ol Tritium (1)
Ci (1) Concentrations less than the lower limit of detection of the counting system used are indicated with a double asterisk -.
Page 1 of 2 Unit I X
Unit 2 Reporting Period January - December 2005 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Est. T A. Fission & Activation Products
- 1. Total Release (not including Tritium, gases, alpha)
- 2. Average diluted concentration during reporting period B. Tritium 1.Total release
- 2. Average diluted concentration during the repoorting period C. Dissolved and Entrained Gases
- 1. Total release
- 2. Average diluted concentration during the reporting period D. Gross Aloha Radioactivity
- 1. Total release Ci
~CUiIm Ci PC!/Im Ci
~CUiIm No Releases No Releases INo Releases No ReleasesI 5.OOE+01 No Releases No Releases No Releases No Releases No Releases l No Releases [No Releases INo Releases I 5.OOE+01 No Releases No Releases [No Releases INo Releases I No Releases I No Releases I No Releases No Releases I 5.OOE+01 No Releases I No Releases I No Releases INo Releases Ci INo Releases INo Releases I No Releases I No Releases I 5.OOE+01 E. Volumes
- 1. Prior to Dilution
- 2. Volume of dilution water used during release period
- 3. Volume of dilution water available during reporting period F. Percent of Tech. Spec. Limits Fission and Activation Gases Percent of Quarterly Whole Body Dose Limit (1.5 mrem)
Percent of Annual Whole Body Dose Limit to Date (3 mrem)
Percent of Quarterly Organ Dose Limit (5 mrem)
Percent of Annual Organ Dose Limit to Date (10 mrem)
Percent of 1 OCFR20 Concentration Limit Percent of Dissolved or Entrained Noble Gas Limit (2.OOE-04 pCi/ml)
Liters Liters Liters No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases 1.15E+11 1.02E+11 1.38E+11 1.33E+11 No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases 5.001E+01 5.OOE+01 5.OOE+01 Page 2 of 2 Unit 1 X
Unit 2 Reporting Period January - December 2005 LIQUID EFFLUENTS RELEASED Batch Mode (1)
Nuclides Released 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Nuclides Released Strontium-89 Strontium-90 Cesium-134 Cesium-137 Iodine-131 Ci Ci Ci Ci Ci Cobalt-58 Cobalt-60 Iron-59 Zinc-65 Manganese-54 Chromium-51 Ci Ci Ci Ci Ci Ci Zirconium-95 Niobium-95 Molybdenum-99 Barium-140 Lanthanum-140 Cerium-141 Ci Ci Ci Ci Ci Ci No Releases l No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases No Releases Iodine-133 Iron-55 Cerium-144 Cesium-136 Copper-64 Manganese-56 Nickel-65 Sodium-24 Ci Ci Ci Ci Ci Ci Ci Ci Dissolved or Entrained Gases Ci Tritium Ci (1) No continuous mode release occurred during the report period as indiacted by effluent sampling.
Page 1 of 4 Unit 1 X
Unit 2 Reporting Period January - December 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.1 TYPE Volume Activity (1)
(m3)
(Ci)
Class Class A
B C
A B
C a.1 Spent Resin (Dewatered) 9.47E+01 O.OOE+00 O.OOE+00 3.52E+02 O.OOE+00 O.OOE+00 a.2 Filter Sludge O.OOE+00 2.71 E+01 O.OOE+00 O.OOE+00 9.15E+02 O.OOE+00 Totals 9.47E+01 2.71 E+01 O.OOE+00 3.52E+02 9.15E+02 0.00E+00
- b. Dry Active Waste, Compressible and Non-1.02E+03 O.OOE+00 O.OOE+00 1.48E+00 O.OOE+00 O.OOE+00 Compressible (Contaminated Equipment)
- c. Irradiated Components, O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Control Rods I
- d. Other (to vendor for processing)
- 1. Sewage Sediment 1
1.98E+01 l O.OOE+00 l O.OOE+00 l 2.38E-05 T O.OOE+00 I O.OOE+00
- 2. Batteries 3.63E+01 O.OOE+00 O.OOE+00 2.23E-05 O.OOE+00 O.OOE+00 (1) The estimated total error is 5.OE+01 %
Page 2 of 4 Unit 1 X
Unit 2 Reporting Period January - December 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Al. TYPE Container Package Solidification Agent a.1 Spent Resin (Dewatered)
Poly Liner General Design, Type A None a.2 Filter Sludge Poly Liner Type A / Type B None
- b. Dry Active Waste, Compressible and Non-Metal Box General Design None Compressible (Contaminated Equipment)
- c. Irradiated Components, l
N/A l
N/A N/A Control Rods f
I
- d. Other (to vendor for processing)
- 1. Sewage Sediment Metal Box General Design None
- 2. Batteries Metal Box General Design None Page 3 of 4 Unit 1 X
Unit 2 Reporting Period January - December 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A2. ESTIMATE OF MAJOR NUCLIDE COMPOSITION (BY TYPE OF WASTE)
- a. Spent Resins, Filter Sludges, Concentrated Waste Nuclide Percent Fe-55 51.6 Co-60 37.4 Mn-54 4.9 Cs-1 37 3.5 Other 2.6
- b. Dry Compressible Waste, Dry Non-Compressible Waste (Contaminated Equipment)
Nuclide Percent Fe-55 69.4 Co-60 22.6 Cs-1 37 4.4 Mn-54 2.4 Other 1.2
- c. Irradiated Components, Control Rods Nuclide 1
Percent N/A I
N/A
- d. Other: (To vendor for processing)
- 2. Batteries Nuclide Percent H-3 100 Page 4 of 4 Unit 1 X
Unit 2 Reporting Period January-December 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A3. SOLID WASTE DISPOSITION Number of Shipments Mode of Transportation Destination 27 Hittman Transport Studsvik Processing Facility 15 Race Logistics Race, LLC 3
Hittman Transport Duratek Services, CVRF I
Hittman Transport Duratek Services, GRF 1
Southern Pines Trucking Alarun Corporation B. IRRADIATED FUEL SHIPMENTS (Disposition)
Number of Shipments Mode of Transportation Destination 0
N/A N/A D. SEWAGE WASTES SHIPPED TO A TREATMENT FACILITY FOR PROCESSING AND BURIAL See A.d.1 Page 1 of 1 Unit I X
Unit 2 Reporting Period January - December 2005
SUMMARY
OF CHANGES TO THE OFF-SITE DOSE CALCULATION MANUAL (ODCM)
The Unit 1 Off-Site Dose Calculation Manual (ODCM) was revised during the reporting period to add a new food product sample location and a new milk sample location and to delete two milk sample locations because the samples are no longer available. These changes are in conformance with the ODCM Part I and S-ENVSP-18 procedural requirements. These changes do not affect the levels of radioactive effluent control required by 10 CFR 20.1302, 40 CFR 190, 10 CFR 50.36a, and 10 CFR 50 Appendix I, and do not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations. A copy of the ODCM, Revision 26 is attached (Attachment 12) and a summary of the changes presented to and approved by the Station Operations Review Committee on December 20, 2005 is provided below. The summary also includes the justification for the change.
REVISION 26 New/Amended Page #
Section #
Description of Reason for Change Change 11 71 Table 5.1 Added a new sample During the 2005 land census a new food product location 1173 Figure 5.1-2 location for food product, was selected. The new food product location is at 1.52 map location 68/produce miles @85° E. The current food product location is 1.76 location #18 (1.52 miles miles @970 E. This new location is in the same sector of East (850 E) of Nine Mile the current location and has the same site average D/Q.
Point.
1170 Table 5.1 Added Milk location #76 Milk locations #50 and #60 are no longer available. These 1173 Figure 5.1-2 and removed milk locations are not required by the ODCM. They are not locations #50 and #60.
within 5 miles nor do they meet the requirements of a control location (9-20 miles distant and in the least prevailing wing direction). This change is administrative, the new location is consistent with the previous location
- 50, i.e., similar wind direction and within the 5 - 9 mile distance.
Page 1 of 1 Unit 1 X
Unit 2 Reporting Period January - December 2005
SUMMARY
OF CHANGES TO THE PROCESS CONTROL PROGRAM (PCP)
There were no changes to the NMP1 Process Control Program (PCP) during the report period.
Page 1 of 1 Unit I X
Unit 2 Reporting Period January - December 2005
SUMMARY
OF INOPERABLE MONITORS There were no inoperable monitors for a period of greater than 30 days for the period.
0 Page 1 of 3 Unit 1 X Unit 2 Reporting Period Januarv -December 2005 DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE THE SITE BOUNDARY Introduction An assessment of the radiation dose potentially received by a Member of the Public due to their activities inside the site boundary from Nine Mile Point Unit 1 (NMP1) liquid and gaseous effluents has been conducted for the period January through December 2005.
This assessment considers the maximum exposed individual and the various exposure pathways resulting from liquid and gaseous effluents to identify the maximum dose received by a Member of the Public during their activities within the site boundary.
Prior to September 11, 2001, the public had access to the Energy Information Center for purposes of observing the educational displays or for picnicking and associated activities. Fishing also occurred near the shoreline adjacent to the NMP. Fishing near the shoreline adjacent to the NMP Site was the onsite activity that resulted in the potential maximum dose received by a Member of the Public. Following September 11, 2001 public access to the Energy Information Center has been restricted and fishing by Members of the Public at locations on site is also prohibited. Although fishing was not conducted during 2005 the annual dose to a hypothetical fisherman was still evaluated to provide continuity of data for the location.
Dose Pathways Dose pathways considered for this evaluation included direct radiation, inhalation and external ground (shoreline sediment or soil doses). Other pathways, such as ingestion pathways. are not considered because they are either not applicable, insignificant, or are considered as part of the evaluation of the total dose to a member of the public located off-site. In addition. only releases from the NMP1 stack and emergency condenser vent were evaluated for the Inhalation pathway, Dose due to aquatic pathways such as liquid effluents is not applicable since swimming is prohibited at the Nine Mile Point Site.
Dose to a hypothetical fisherman is received through the following pathways while standing on the shoreline fishing:
External ground pathway; this dose is received from plant related radionuclides detected in the shoreline sediment.
Inhalation pathway; this dose is received through inhalation of gaseous effluents released from NMP1 Stack and Emergency Condenser Vent.
Direct radiation pathway; dose resulting from the operation of NMP1, Nine Mile Point Unit 2 (NMP2) and the James A.
Fitzpatrick (JAF) Facilities.
Methodologies for Determining Dose for Applicable Pathwavs External Ground (Shoreline Sediment) Dathwav Dose from the external around (shoreline sediment) Is based on the methodology In the NMPI Offsite Dose Calculation Manual (NMP1 ODCM) as adapted from Reaulatory Guide 1.109. For this evaluation it is assumed that the hypothetical maximum exposed individual fished from the shoreline at all times.
The total dose received by the whole body and skin of the maximum exposed Individual during 2005 was calculated using the following input parameters:
Usage Factor = 312 hours0.00361 days <br />0.0867 hours <br />5.15873e-4 weeks <br />1.18716e-4 months <br /> (fishing 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> per week, 39 weeks per year)
Density in grams per square meter = 40,000 Shore width factor = 0.3 Whole body and skin dose factor for each radionuclide = Regulatory Guide 1.109, Table E-6.
Fractional portion of the year = 1 (used average radionuclide concentration over total time period)
Average Cs-137 concentration = 1.75E-01 pCi/g The total whole body and skin doses received by a hypothetical maximum exposed fisherman from the external ground pathway is presented in Table 1, Exposure Pathway Dose.
0 Page 2 of 3 Unit 1 X Unit2 2 Reporting Period January-December 2005 DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE THE SITE BOUNDARY Inhalation Pathway The inhalation dose pathway is evaluated by utilizing the inhalation equation in the NMP1 ODCM, as adapted from Regulatory Guide 1.109. The total whole body dose and organ dose received by the hypothetical maximum exposed fisherman during 2005 calculated using the following input parameters for gaseous effluents released from both the NMP1 Stack and Emergency Condenser Vent for the time period exposure is received:
NMP I Stack:
Variable Fisherman
- XIQ (s/iM3) 8.9E-06 Inhalation dose factor Table E-7 Regulatory Guide 1.109 Annual air intake m3/year) (adult) 8000 Fractional portion of the year (hours) 0.0356 H-3 (pCi/sec) 1.43E+06 Cr-51 (pCi/sec) 7.05E+00 Mn-54 (pCi/sec) 8.99E+00 Fe-55 (pCi/sec) 8.69E+00 Co-58 (pCi/sec) 2.51 E+00 Co-60 (pCi/sec) 9.62E+01 Cs-1 37 (pCi/sec) 3.04E-01 1-131 (pCi/sec) 2.62E+01 1-133 (pCi/sec) 5.19E+01 ergency Condenser Vent:
Variable Fisherman XIQ (s/iM3) 6.63E-06 Inhalation dose factor Table E-7 Regulatory Guide 1.109 Annual air intake m3/year) (adult) 8000 Fractional portion of the year 0.0356 H-3 (pCi/sec) 2.99E+05 NMP1 Er The maximum exposed fisherman is assumed to be present on site during the period of April through December at a rate of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> per week for 39 weeks per year equivalent to 312 hours0.00361 days <br />0.0867 hours <br />5.15873e-4 weeks <br />1.18716e-4 months <br /> for the year (fractional portion of the year =
0.0356). Therefore, the Average Stack and Vent flow rates and radionuclide concentrations used to determine the dose are represented by second, third and fourth quarter gaseous effluent flow and concentration values.
The total whole body dose and maximum organ dose received by the hypothetical maximum exposed fisherman is presented in Table 1, Exposure Pathway Dose.
0 Page 3 of 3 Unit 1 X Unit 2 Reporting Period January -December 2005 DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE THE SITE BOUNDARY Direct Radiation Pathway The direct radiation pathway is evaluated in accordance with the methodology found in the NMP1 ODCM. This pathway considers four components: direct radiation from the generating facilities, direct radiation from any possible overhead plume, direct radiation from ground deposition and direct radiation from plume submersion. The direct radiation pathway is evaluated by the use of high sensitivity environmental Thermoluminescent Dosimeters (TLDs). Since fishing activities occur between April 1 - December 31, TLD data for the second, third, and fourth quarters of 2005 from TLDs placed in the general area where fishing once occurred were used to determine an average dose to the hypothetical maximum exposed fisherman from direct radiation. The following is a summary of the average dose rate and assumed time spent on site used to determine the total dose received:
Variable Fisherman Average Dose Rate (mRem/hr) 1.59E-03 Exposure time (hours) 312 Total Doses received by the hypothetical maximum exposed fisherman from direct radiation is presented in Table 1, Exposure Pathway Annual Dose Dose Received By A Hypothetical Maximum Exposed Member Of The Public Inside the Site Boundary During 2005 The following is a summary of the dose received by a hypothetical maximum exposed fisherman from Liquid and Gaseous effluents released from NMP1 during 2005:
TABLE I Exposure Pathway Annual Dose Exposure Pathway Dose Type Fisherman (mRem)
External Ground Whole Body 2.79E-03 Skin of Whole Body 3.25E-03 Inhalation Whole Body 6.62E-04 Maximum Organ Thyroid: 4.35E-04 Direct Radiation Whole Body 0.50 Based on these values the total annual dose received by a hypothetical maximum exposed member of the public inside the site boundary is as follows:
TABLE 2 Annual Dose Summary Total Annual Dose for 2005 Fisherman Total Whole Body (mRem) 0.50 Skin of Whole Body (mRem) 3.25E-03 Maximum Organ (mRem)
I Thyroid: 4.35E-04 1
Page 1 of 2 Unit 1 X Unit 2 Reporting Period January-December 2005 DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES OUTSIDE THE SITE BOUNDARY Introduction An assessment of radiation doses potentially received by the likely most exposed member of the public located beyond the site boundary was conducted for the period January through December 2005 for comparison against the 40 CFR 190 annual dose limits.
The intent of 40 CFR 190 requires that the effluents of Nine Mile Point Unit 1 (NMPI), as well as other nearby uranium fuel cycle facilities, be considered. In this case, the effluents of NMP1, Nine Mile Point Unit 2 (NMP2) and the James A.
FitzPatrick (JAF) facilities must be considered.
40 CFR 190 requires the annual radiation dose received by members of the public in the general environment, as a result of plant operations, be limited to:
< 25 mRem wholebody
< 25 mRem any organ (except thyroid) c 75 mRem thyroid This evaluation compares doses resulting from Liquid and Gaseous effluents and direct radiation originating from the site as a result of the operation of the NMP1, NMP2 and JAF nuclear facilities.
Dose Pathways Dose pathways considered for this evaluation included doses resulting from liquid effluents, gaseous effluents and direct radiation from all nuclear operating facilities located on the Nine Mile Point Site.
Dose to the most likely member of the public, outside the site boundary, is received through the following pathways:
Fish consumption pathway; this dose is received from plant radionuclides that have concentrated in fish that is consumed by a member of the public.
Shoreline Sediment; this dose is received as a result of an individual's exposure to plant radionuclides deposited in the shoreline sediment, which is used as a recreational area.
Deposition, Inhalation and Ingestion pathways resulting from gaseous effluents; this dose is received through exposure to gaseous effluents released from NMP1, NMP2 and JAF operating facilities.
Direct Radiation pathway; radiation dose resulting from the operation of NMP1, NMP2 and JAF facilities.
Methodologies for Determininc Dose for Applicable Pathways Fish Consumption Dose received as a result of fish consumption is based on the methodology specified in the.MPI Off-site Dose Calculation Manual (NMP1 ODCM) as adapted from Regulatory Guide 1 109. The dose for 2005 is calculated from actual analysis results of environmental fish samples taken near the site discharge points. For this evaluation it is assumed that the most likely exposed member of the public consumes fish taken near the site discharge points.
i No radionuclides were detected in fish samples collected and analyzed during 2005; therefore no dose was received by the whole body and organs of the likely most exposed Member of the Public during 2005.
Shoreline Sediment Dose received from shoreline sediment is based on the methodology in the NMP1 ODCM as adapted from Regulatory Guide 1.109. For this evaluation it is assumed that the most likely exposed member of the public spends 67 hour7.75463e-4 days <br />0.0186 hours <br />1.107804e-4 weeks <br />2.54935e-5 months <br />s/year along the shoreline for recreational purposes.
1 Page 2 of 2 Unit 1 X Unit 2 Reporting Period January-December 2005 DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES OUTSIDE THE SITE BOUNDARY Shoreline Sediment Continued:
The total dose received by the whole body and skin of the maximum exposed individual during 2005 is calculated using the following input parameters:
Usage Factor = 67 hours7.75463e-4 days <br />0.0186 hours <br />1.107804e-4 weeks <br />2.54935e-5 months <br /> per year Density in grams per square meter = 40,000 Shore width factor = 0.3 Whole body and skin dose factor for each radionuclide = Regulatory Guide 1.109, Table E-6 Fractional portion of the year = I Average Cs-137 Concentration = 0.076 pCilg Dose Pathways Resulting From Gaseous Effluents Dose received by the likely most exposed member of the public due to gaseous effluents is calculated in accordance with the methodology provided in the NMP1 ODCM, NMP2 Offsite Dose Calculation Manual, and the JAF Offsite Dose Calculation Manual. These calculations consider deposition, inhalation and ingestion pathways. The total sum of doses resulting from gaseous effluents from NMP1, NMP2 and JAF during 2005 provide a total dose to the whole body and maximum organ dose for this pathway.
Direct Radiation Pathwa, Dose as a result of direct gamma radiation from the site, encompasses doses from direct "shine' from the generating facilities, direct radiation from any overhead gaseous plumes, plume submersion and from ground deposition. This total dose is measured by environmental TLDs. The critical location is based on the closest year-round residence from the generating facilities as well as the closest residence in the critical downwind sector in order to evaluate both direct radiation from the generating facilities and gaseous plumes as determined by the local meteorology. During 2005, the closest residence and the critical downwind residence are at the same location.
Dose Potentially Received by the Likely Most Exposed Member of the Public Outside the Site Boundary During 2005 I Exposure Pathwav Dose Tvoe Dose (mRem)
Fish Consumption Total Whole Body No Dose Total Maximum Organ No Dose Shoreline Sediment Total Whole Body 2.58E-04 Total Skin of Whole Body 3.01E-04 Gaseous Effluents Total Whole Body 1.69E-2 Total Maximum Organ Thyroid: 1.55E-01 Direct Radiation Total Whole Body 1.49 Based on these values the maximum total annual dose potentially received by the most likely exposed member of the public during 2005 is as follows:
Total Whole Body:
1.51 mRem Total Skin of Whole Body:
1.31 E-02 mRem Maximum Organ:
Thyroid: 1.55E-01 mRem 40 CFR 190 Evaluation The maximum total doses presented in this attachment are the result of operations at the NMP1, NMP2 and the JAF facilities. The maximum organ dose (Thyroid: 0.155 mRem) and the maximum whole body dose (1.51 mRem) are below the 40 CFR 190 criteria of 25 mRem per calendar year to the maximum exposed organ or the whole body, and below 75 mRem per calendar year to the thyroid.
2 Off-Site Dose Calculation Manual (ODCM)
I