ML061240251
| ML061240251 | |
| Person / Time | |
|---|---|
| Site: | Farley |
| Issue date: | 12/31/2005 |
| From: | Southern Nuclear Operating Co |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| NL-06-0869 | |
| Download: ML061240251 (100) | |
Text
ENCLOSURE 2 Joseph M. Farley Nuclear Plant Annual Radioactive Effluent Release Report for 2005
SOUTHERN NUCLEAR OPERATING COMPANY FARLEY NUCLEAR PLANT UNIT NO. ONE LICENSE NO. NPF-2 AND FARLEY NUCLEAR PLANT UNIT NO. TWO LICENSE NO. NPF-8 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT CALENDAR YEAR 2005
FARLEY NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SECTION TITLE PAGE 1.0 LIQUID EFFLUENTS 1
1.1 Regulatory Requirements 1
1.1.1 Concentration Limits 1
1.1.2 Dose Limits 1
1.2 Effluent Concentration Limit (ECL) 1 1.3 Measurements and Approximation 2
of Total Radioactivity 1.3.1 Total Radioactivity Determination 2
1.3.2 Total Error Estimation 3
1.4 Liquid Effluents -
Release Data 3
1.5 Radiological Impact Due to Liquid Releases 3
1.6 Liquid Effluents -
Batch Releases 3
1.7 Liquid Effluents -
Abnormal Releases 4
2.0 GASEOUS EFFLUENTS 36 2.1 Regulatory Requirements 36 2.1.1 Dose Rate Limits 36 2.1.2 Air Doses Due to Noble Gases in 36 Gaseous Releases 2.1.3 Doses to a Member of the Public 37 2.2 Measurements and Approximation 37 of Total Radioactivity 2.2.1 Sample Collection and Analysis 37
FARLEY NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SECTION TITLE PAGE 2.2.2 Total Quantities of Radioactivity, Dose 38 Rates and Cumulative Doses 2.2.2.1 Fission and Activation Gases 38 2.2.2.2 Radioiodine, Tritium and Particulate 38 Releases 2.2.2.3 Gross Alpha Release 39 2.2.3 Total Error Estimation 40 2.3 Gaseous Effluent Release Data 40 2.4 Radiological Impact Due to Gaseous 41 Releases 2.5 Gaseous Effluents -
Batch Releases 41 2.6 Gaseous Effluents - Abnormal Releases 41 3.0 SOLID WASTE 77 3.1 Regulatory Requirements 77 3.1.1 Solid Radioactive Waste System 77 3.1.2 Reporting Requirements 77 3.2 Solid Waste Data 77 4.0 DOSES TO MEMBERS OF THE PUBLIC 82 INSIDE THE SITE BOUNDARY 4.1 Regulatory Requirements 82 4.2 Demonstration of Compliance 82
FARLEY NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SECTION TITLE PAGE 5.0 TOTAL DOSE FROM URANIUM FUEL 89 CYCLE (40CFR190) 5.1 Regulatory Requirements 89 5.2 Demonstration of Compliance 89 6.0 METEOROLOGICAL DATA 89 7.0 PROGRAM DEVIATIONS 89 7..1 Inoperable Liquid or Gaseous Effluent 89 Monitoring Instrumentation 7.1.1 Regulatory Requirements 89 7.1.2 Description of Deviations 89 7.2 Effluent Sample Analysis Exceeding 90 Minimum Detectable Concentration (MDC) 7.2.1 Regulatory Requirements 90 7.2.2 Description of Deviations 90 7.3 Incorrect Compositing of Liquid 90 or Gaseous Effluent Samples 7.3.1 Regulatory Requirements 90 7.3.2 Description of Deviations 90 8.0 CHANGES TO THE PLANT FARLEY ODCM 90 8.1 Regulatory Requirements 90 8.2 Description of Changes 90
SECTION FARLEY NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT TITLE MAJOR CHANGES TO LIQUID, GASEOUS, OR SOLID RADWASTE TREATMENT SYSTEMS Regulatory Requirements Description of Major Changes PAGE 9.0 9.1 9.2 91 91 91
FARLEY NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT TABLE LIST OF TABLES PAGE 1-lA Liquid Effluents -
Summation of 5
All Releases, Unit 1 (Quarters 1,2, 3 and 4) 1-lB Liquid Effluents -
Summation of 7
All Releases, Unit 2 (Quarters 1,2, 3 and 4) 1-iC Liquid Effluents -
Summation of 9
All Releases, Site (Quarters 1,2, 3 and 4) 1-2A Liquid Effluents, Unit 1 (Quarters 1,2, 11 3 and 4) 1-2B Liquid Effluents, Unit 2 (Quarters 1,2, 15 3 and 4) 1-2C Liquid Effluents, Site (Quarters 1,2, 19 3 and 4) 1-3A Doses to a MEMBER OF THE PUBLIC 23 Due to Liquid Releases, Unit 1 (Quarters 1,2,3 and 4) 1-3B Doses to a MEMBER OF THE PUBLIC 25 Due to Liquid Releases, Unit 2 (Quarters 1,2,3 and 4) 1-4 Minimum Detectable Concentration -
27 Liquid Sample Analyses 1-5A Liquid Effluents -
Batch Release 28 Summary, Unit 1 1-5B Liquid Effluents -
Batch Release 30 Summary, Unit 2
FARLEY NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT TABLE LIST OF TABLES PAGE 1-6A Liquid Effluents -
Abnormal Release 32 Summary, Unit 1 1-6B Liquid Effluents -
Abnormal Release 34 Summary, Unit 2 2-1A Gaseous Effluents -
Summation of 42 All Releases, Unit 1 (Quarters 1,2, 3 and 4) 2-1B Gaseous Effluents -
Summation of 44 All Releases, Unit 2 (Quarters 1,2, 3 and 4) 2-1C Gaseous Effluents - Summation of 46 All Releases, Site (Quarters 1,2, 3 and 4) 2-2A Gaseous Effluents -
Mixed Mode 48 Level Releases, Unit 1 (Quarters 1,2, 3 and 4) 2-2B Gaseous Effluents - Mixed Mode 50 Level Releases, Unit 2 (Quarters 1,2, 3 and 4) 2-2C Gaseous Effluents - Mixed Mode 52 Level Releases, Site (Quarters 1,2, 3 and 4) 2-3A Gaseous Effluents -
Ground 54 Level Releases, Unit 1 (Quarters 1,2, 3 and 4) 2-3B Gaseous Effluents -
Ground 56 Level Releases, Unit 2 (Quarters 1,2, 3 and 4) 2-3C Gaseous Effluents -
Ground 58 Level Releases, Site (Quarters 1,2, 3 and 4)
FARLEY NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT TABLE LIST OF TABLES PAGE 2-4A Air Doses Due to Noble Gases in 60 Gaseous Releases, Unit 1 (Quarters 1,2, 3 and 4) 2-4B Air Doses Due to Noble Gases in 62 Gaseous Releases, Unit 2 (Quarters 1,2, 3 and 4) 2-5A Doses to a MEMBER OF THE PUBLIC 64 Due to Radioiodines, Tritium, and Particulates in Gaseous Releases, Unit 1 (Quarters 1,2,3 and 4) 2-5B Doses to a MEMBER OF THE PUBLIC 66 Due to Radioiodines, Tritium, and Particulates in Gaseous Releases, Unit 2 (Quarters 1,2,3 and 4) 2-6 Minimum Detectable Concentration -
68 Gaseous Effluent Analyses 2-7A Gaseous Effluents -
Batch Release 69 Summary, Unit 1 2-7B Gaseous Effluents -
Batch Release 71 Summary, Unit 2 2-8A Gaseous Effluents - Abnormal Release 73 Summary, Unit 1 2-8B Gaseous Effluents - Abnormal Release 75 Summary, Unit 2 3-1 Solid Waste and Irradiated 78 Fuel Shipments 4-1 Doses to a MEMBER OF THE PUBLIC 83 Due to Activities Inside the Site Boundary, Site
1.0 LIQUID EFFLUENTS This section contains applicable ODCM limits for liquid effluents as well as the quantities of radioactive liquid effluents released during 2005. These quantities are summarized on a quarterly basis and include any unplanned releases. A tabulation of the total body and organ doses which were calculated in accordance with ODCM 2.4 are presented to show conformance with the limits of ODCM 2.1.3.
1.1 Regulatory Requirements 1.1.1 Concentration Limits Technical Specifications 5.5.4.b and 5.5.4.c state that the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS (see ODCM Figure 10-1) shall be limited at all times to ten times the concentrations specified in 10CFR20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 1.OE-04 uCi/ml total activity.
1.1.2 Dose Limits Technical Specifications 5.5.4.d and 5.5.4.e state that the dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to UNRESTRICTED AREAS (see ODCM Figure 10-1) shall be limited:
- a. During any calendar quarter to less than or equal to 1.5 mrem to the total body and to less than or equal to 5 mrem to any organ, and
- b. During any calendar year to less than or equal to 3 mrem to the total body and to less than or equal to 10 mrem to any organ.
1.2 Effluent Concentration Limit (ECL)
ECL values used in determining allowable liquid radwaste release rates and concentrations, for principal gamma emitters, I-131, tritium, Sr-89, Sr-90 and Fe-55, are taken from 10CFR Part 20, Appendix B, Table 2, Column 2. A tolerance factor of up to 10 is utilized to allow flexibility in establishing practical monitor setpoints which can accommodate effluent releases at concentrations higher than the ECL values stated in 10CFR20, Appendix B, Table 2, Column 2.
For dissolved or entrained noble gases in liquid radwaste, the ECL is 1.OE-04 uCi/ml total activity.
For gross alpha in liquid radwaste, the ECL is 2.OE-09 uCi/ml.
1
Furthermore, for all the above radionuclides, or categories of radioactivity, the overall ECL fraction is determined in accordance with 10CFR Part 20, Appendix B.
1.3 Measurements and Approximation of Total Radioactivity The radionuclides listed below are considered when evaluating liquid effluents:
MN-54 CS-134 FE-59 CS-137 CO-58 CE-141 CO-60 CE-144 ZN-65 MO-99 SR-89 FE-55 SR-90 H-3 1-131 1.3.1 Total Radioactivity Determination Batch Releases: Representative pre-release grab samples are obtained and analyzed in accordance with ODCM Table 2-3.
Isotopic analyses are performed using the computerized pulse height analysis system utilizing high resolution germanium detectors. Isotopic values thus obtained are used for release rate calculations as specified in the ODCM. Only those nuclides that are detected are used in the calculations. All Strontium and Iron-55 samples are sent offsite to the Georgia Power Environmental Laboratory for analysis. Gross beta and gross alpha determinations are made using 2 pi gas flow proportional counters. Tritium determinations are made using liquid scintillation techniques. Dissolved gases are determined employing grab sampling techniques and then counting on the pulse height analyzer.
The sample analyses results are used along with the ECL values to determine the ECL fraction for the planned release. The ECL fraction is then used, with the appropriate safety factors, and the expected dilution stream flow, to calculate the maximum permissible release rate and a liquid effluent monitor setpoint.
The monitor setpoint is calculated to assure that the limits of the ODCM are not exceeded. A monitor reading in excess of the calculated setpoint will result in automatic termination of the liquid radwaste discharge.
Radionuclide concentrations, safety factors, dilution stream flow rate, and liquid effluent radiation monitor calibration factors are used by the computer to generate a pre-release printout. If the release is not permissible, appropriate warnings will be displayed on the computer screen and on the printout. If the release is permissible, it is approved by a Chemistry Technician.
The release permit is transferred from the Chemistry Department to the Operations Department for release. When the release is completed, the actual release data are provided to the Chemistry 2
Department. These release data, including release rate and release duration, are input into the computer and a post-release printout is generated. This printout contains the actual release rates, radionuclide concentrations and quantities, dilution flow, and calculated doses to an individual.
Continuous Releases: Continuous releases are analogous to batch releases except that they are analyzed on a weekly composite basis in accordance with ODCM Table 2-3.
Typically achieved liquid effluent sample analyses minimum detectable concentrations are reported in Table 1-4.
1.3.2 Total Error Estimation The maximum error associated with volume and flow measurements, based upon plant calibration practice is estimated to be + or -
10%. The average error associated with counting is estimated to be less than + or -
15%.
1.4 Liquid Effluent Release Data Summaries of all radioactive liquid effluents released from Units 1 and 2 during 2005 are presented in accordance with Regulatory Guide 1.21 Tables 2A and 2B. Information required by Table 2A is found in this report in Tables 1-lA, 1-lB, and l-lC; Table 2-B information is presented in Tables 1-2A, 1-2B, and 1-2C. Data is presented on a quarterly basis as required by Regulatory Guide 1.21 for all four quarters.
1.5 Radiological Impact Due to Liquid Releases The total body and organ doses for Units 1 and 2 are provided in the following tables in order to show conformance with the limits of ODCM 2.1.3:
Unit 1 2005 Doses to a Member of the Public due to Liquid Releases: Table 1-3A Unit 2 2005 Doses to a Member of the Public due to Liquid Releases: Table 1-3B 1.6 Liquid Effluents - Batch Releases Batch release information for Units 1 and 2 is summarized in the following tables:
Unit 1 2005 Liquid Effluents - Batch Release Summary: Table 1-SA Unit 2 2005 Liquid Effluents - Batch Release Summary: Table 1-5B 3
1.7 Liquid Effluents - Abnormal Releases There were no abnormal releases on Unit 1 during 2005.
There was one abnormal release on Unit 2 during 2005. On 11/04/2005 approximately two gallons of water were spilled during steam generator sludge lancing. No limits were exceeded as a result of this abnormal release. Details of this event are documented in condition report 2005111153.
Abnormal release information for Units 1 and 2 is summarized in the following tables:
Unit 1 2005 Liquid Effluents - Abnormal Release Summary: Table 1-6A Unit 2 2005 Liquid Effluents - Abnormal Release Summary: Table 1-6B 4
TABLE 1-lA Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Summation of All Releases Unit: 1 Starting : 1-Jan-2005 Ending : 30-Jun-2005 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
CURIES 5.21E-03 1.95E-02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 3.86E-10 1.23E-09
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE CURIES 5.OOE+01 3.02E+02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 3.70E-06 l.91E-05
- 3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE CURIES 3.70E-05 l.llE-03 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 2.74E-12 7.OOE-11
- 3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEASE CURIES 0.OOE+00 0.OOE+00 1.80E+01 E. WASTE VOL RELEASED(PRE-DILUTION)
LITERS 7.OOE+05 4.93E+07 1.OOE+01 F. VOLUME OF DILUTION WATER USED LITERS 1.35E+10 1.58E+10 1.OOE+01 Applicable limits are expressed in terms of dose.
See Tables 1-3A and 1-3B of this report.
5
TABLE 1-lA Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Summation of All Releases Unit: 1 Starting : l-Jul-2005 Ending : 31-Dec-2005 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
CURIES 2.20E-02 1.61E-02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.29E-09 9.76E-10
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE CURIES l.llE+02 1.32E+02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 6.48E-06 8.OOE-06
- 3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE CURIES 2.44E-04 7.90E-04 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.43E-11 4.79E-ll
- 3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEASE CURIES 0.OOE+00 0.OOE+00 1.80E+01 E. WASTE VOL RELEASED(PRE-DILUTION)
LITERS 1.65E+07 1.30E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 1.71E+10 1.65E+10 1.00E+01 Applicable limits are expressed in terms of dose.
See Tables 1-3A and 1-3B of this report.
6
TABLE 1-lB Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Summation of All Releases Unit: 2 Starting :
l-Jan-2005 Ending : 30-Jun-2005 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
CURIES 1.22E-02 4.26E-02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 8.76E-10 2.51E-09
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE CURIES 1.20E+02 3.51E+02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 8.62E-06 2.07E-05
- 3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE CURIES 2.30E-05 1.06E-03 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.65E-12 6.25E-ll
- 3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEASE CURIES 0.OOE+00 0.OOE+00 1.80E+01 E. WASTE VOL RELEASED(PRE-DILUTION)
LITERS 1.92E+07 4.97E+07 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 1.39E+10 1.69E+10 1.OOE+01 Applicable limits are expressed in terms of dose.
See Tables 1-3A and 1-3B of this report.
7
TABLE 1-lB Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Summation of All Releases Unit: 2 Starting :
1-Jul-2005 Ending : 31-Dec-2005 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
CURIES 5.50E-02 3.10E-02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 3.23E-09 2.21E-09
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE CURIES 1.90E+02 5.92E+01 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.12E-05 4.23E-06
- 3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE CURIES 1.34E-03 5.92E-04 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 7.87E-11 4.23E-11
- 3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEAS C________________E_______
0___E___
___O_____0 l______0E_+______
- 1. TOTAL RELEASE CURIES 0.00E+00 0.00E+00 1.80E+01 E. WASTE VOL RELEASED(PRE-DILUTION)
LITERS 1.76E+07 1.50E+06 1.OOE+01 F. VOLUME OF DILUTION WATER USED LITERS 1.70E+10 1.40E+10 1.OOE+01 Applicable limits are expressed in terms of dose.
See Tables 1-3A and 1-3B of this report.
8
TABLE 1-lC Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Summation of All Releases Unit: Site Starting :
1-Jan-2005 Ending : 30-Jun-2005 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
CURIES 1.74E-02 6.22E-02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 6.35E-10 1.90E-09
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE CURIES 1.70E+02 6.53E+02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 6.20E-06 l.99E-05
- 3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE CURIES 6.OOE-05 2.17E-03 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 2.19E-12 6.62E-11
- 3. PERCENT OF APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEASE CURIES 0.OOE+00 0.OOE+00 1.80E+01 E. WASTE VOL RELEASED(PRE-DILUTION)
LITERS l.99E-07 9.90E+07 1.OOE+01 F. VOLUME OF DILUTION WATER USED LITERS 2.74E+10 3.27E+10 1.00E+01 Applicable limits are expressed in terms of dose.
See Tables 1-3A and 1-3B of this report.
9
TABLE 1-iC Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Summation of All Releases Unit: Site Starting 1-Jul-2005 Ending : 31-Dec-2005 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
CURIES 7.70E-02 4.71E-02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 2.26E-09 1.54E-09
- 3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
- 1. TOTAL RELEASE CURIES 3.01E+02 l.91E+02 1.80E+01
- 2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 8.82E-06 6.24E-06
- 3. PERCENT OF APPLICABLE LIMIT C.
DISSOLVED AND ENTRAINED GASES
- 1.
TOTAL RELEASE CURIES 1.59E-03 1.38E-03 1.80E+01
- 2.
AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 4.66E-11 4.51E-11
- 3.
PERCENT OF APPLICABLE LIMIT D.
GROSS ALPHA RADIOACTIVITY
- 1.
TOTAL RELEASE CURIES 0.OOE+00 0.OOE+00 1.80E+01 E. WASTE VOL RELEASED(PRE-DILUTION)
LITERS 3.41E+07 2.80E+06 1.00E+01 F. VOLUME OF DILUTION WATER USED LITERS 3.41E+10 3.06E+10 1.OOE+01 Applicable limits are expressed in terms of dose.
See Tables 1-3A and 1-3B of this report.
10
TABLE 1-2A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 1 Starting :
1-Jan-2005 Ending : 30-Jun-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT lQUARTER 1 lQUARTER 2 lQUARTER 1 IQUARTER 2 l H-3 I
CURIES I 0.OOE+00 I 0.OOE+00 I 5.OOE+01 I 3.02E+02 I FISSION & ACTIVATION PRODUCTS AG-llOM BE-7 CO-58 CO-60 CR-51 CS-134 CS-137 FE-55 MN-54 NB-95 NB-97 SB-125 SN-113 SN-117M SR-89 SR-90 TE-125M ZN-65 ZR-95 CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES 0.00E+00 0.OOE+00
- 0. OOE+00 l0.OOE+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 l0.OOE+00 l0.00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00 1.32E-03
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 4. 06E-06 2.70E-04 3.80E-04 7.23E-06 0.OOE+00 4.40E-05 9.79E-05 4.43E-06 7.74E-05
- 2. 17E-05
- 9. 51E-06 0.OOE+00 1.84E-05 0.OOE+00 4.57E-06 3.81E-03 4.40E-04 2.31E-05
- 8. 96E-06
- 0. OOE+00 1.llE-04 5.66E-04 0.OOE+00 4.30E-06 1.42E-04 1.20E-04 3.73E-06 1.65E-05
- 4. 17E-05 0.OOE+00 9.85E-07 6.54E-06 1.05E-05 2.46E-04 1.67E-02 3.25E-04
- 0. OOE+00 TOTALS I
CURIES I 0.OOE+00 I 1.32E-03 I 5.21E-03 I 1.82E-02 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
11
TABLE 1-2A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 1 Starting :
l-Jan-2005 Ending : 30-Jun-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE J
UNIT jQUARTER 1 jQUARTER 2 jQUARTER 1 jQUARTER 2 l DISSOLVED AND ENTRAINED GASES XE-131M l CURIES 0.OOE+00 0.OOE+00 2.49E-05 l.l9E-05 XE-133 CURIES 0.OOE+00 0.OOE+00 1.22E-05 1.09E-03 XE-133M CURIES 0.OOE+00 O.OOE+00 O.00E+00 5.24E-06 XE-135 CURIES 0.OOE+00 j 0.OOE+00 0.OOE+00 1.31E-06 TOTALS I
CURIES 0.OOE+00 0.OOE+00 I 3.70E-05 l.llE-03 I G-ALPHA I
CURIES j 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
12
TABLE 1-2A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 1 Starting :
1-Jul-2005 Ending : 31-Dec-2005 I CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT lQUARTER 3 lQUARTER 4 lQUARTER 3 lQUARTER 4 l H-3 I
CURIES I 0.OOE+00 I 0.OOE+00 I l.llE+02 I 1.32E+02 I FISSION & ACTIVATION PRODUCTS AG-llOM CO-57 CO-58 CO-60 CR-51 CS-134 CS-137 CS-138 FE-55 FE-59 I-130 I-131 I-133 I-135 MN-54 MO-99 NB-95 NB-97 NI-56 RU-105 SB-124 SB-125 SN-117M SR-85 SR-89 SR-90 SR-92 CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 4.38E-05 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 6.48E-04 9.37E-07 1.90E-04 3.65E-03
- 0. OOE+00 7.60E-07 1.30E-04 0.OOE+00 1.49E-03 0.OOE+00
- 0. OE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 4.35E-05
- 0. OOE+00 0.OOE+00 2.70E-05
- 0. OOE+00 0.OOE+00 0.OOE+00 1.87E-04 0.OOE+00 0.OOE+00
- 2. 05E-12 1.88E-12 2.44E-05 l 4.72E-05 0.OOE+00 2.21E-03 l 1.49E-03 1.26E-04 l 0.OOE+00 l 4.01E-05 3.91E-06 1.51E-03 8.66E-05 l 2.07E-06 l 5.34E-05 l 8.65E-05 6.38E-06 1.17E-04 2.36E-05 l 4.08E-05 1.77E-05 1.64E-06 1.03E-05 7.82E-05 1.62E-03 2.18E-05 9.14E-07 1.94E-05 l0.OOE+00
- 0. OOE+00 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
13
TABLE 1-2A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 1 Starting :
1-Jul-2005 Ending : 31-Dec-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE j
UNIT jQUARTER 3 lQUARTER 4 lQUARTER 3 IQUARTER 4 l FISSION & ACTIVATION PRODUCTS TC-99M CURIES l0.OOE+00 0.OOE+00 0.OOE+00 7.44E-05 TE-125M CURIES 0.OOE+00 0.OOE+00 1.40E-02 7.18E-03 TE-134 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 1.07E-05 Y-92 CURIES 0.OOE+00 0.OOE+00 7.04E-06 0.OOE+00 ZN-65 CURIES 0.OOE+00 0.OOE+00 1.53E-03 1.19E-03 ZR-95 CURIES 0.OOE+00 j 0.00E+00 0.OOE+00 1.53E-05 TOTALS I
CURIES I 4.38E-05 I 0.OOE+00 I 2.19E-02 1.61E-02 I DISSOLVED AND ENTRAINED GASES AR-41 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 3.BOE-06 KR-85 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 2.02E-04 XE-133 CURIES 0.OOE+00 0.OOE+00 2.38E-04 5.75E-04 XE-135 CURIES O.OOE+00 O.OOE+00 l 5.94E-06 9.OOE-06 TOTALS I
CURIES I O.OOE+00 j 0.OOE+00 I 2.44E-04 I 7.90E-04 t G-ALPHA I
CURIES 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
14
TABLE 1-2B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 2 Starting :
1-Jan-2005 Ending : 30-Jun-2005 l CONTINUOUS MODE I
BATCH MODE NUCLIDE j
UNIT JQUARTER 1 JQUARTER 2 JQUARTER 1 JQUARTER 2 l H-3 j CURIES j 0.OOE+00 0.OOE+00 I 1.20E+02 I 3.51E+02 FISSION & ACTIVATION PRODUCTS AG-llOM CURIES 0.OOE+00 0.OOE+00 8.13E-06 1.29E-05 CO-57 CURIES l0.OOE+00 0.OOE+00 0.OOE+00 4.01E-07 CO-58 CURIES 0.OOE+00 0.OOE+00 1.19E-04 1.36E-04 C0-60 CURIES 0.OOE+00 0.OOE+00 l 3.55E-04 9.35E-04 CR-51 CURIES 0.OOE+00 0.OOE+00 7.07E-06 j 1.58E-05 CS-137 l CURIES 0.OOE+00 0.OOE+00 2.05E-05 2.06E-05 FE-55 CURIES 0.OOE+00 0.OOE+00 5.32E-04 3.36E-04 MN-54 CURIES 0.OOE+00 0.OOE+00 1.15E-06 0.OOE+00 NB-95 CURIES l0.OOE+00 0.OOE+00 5.74E-06 4.46E-06 NB-97 CURIES l0.00E-00 0.OOE+00 1.56E-05 3.68E-05 PR-144 CURIES 0.OOE+00 l0.OOE+00 7.54E-05 0.OOE+00 SN-117M CURIES 0.OOE+00 l0.OOE+00 4.07E-05 3.17E-05 SR-89 CURIES 5.09E-11 7.70E-04 3.87E-08 8.64E-12 TC-101 j CURIES l 0.OOE+00 l 0.OOE+00 l 1.04E-06 1.75E-06 TE-125M CURIES l0.OOE+00 O.OOE+00 1.09E-02 4.01E-02 ZN-65 l CURIES l 0.OOE+00 O.OOE+00 1.56E-04 2.05E-04 ZR-95 CURIES 0.OOE+00 0.OOE+00 4.18E-06 3.07E-06 TOTALS I
CURIES I 5.09E-11 I 7.70E-04 I 1.22E-02 I 4.18E-02 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
15
TABLE 1-2B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 2 Starting : l-Jan-2005 Ending : 30-Jun-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT 1QUARTER 1 1QUARTER 2 IQUARTER 1 1QUARTER 2 l DISSOLVED AND ENTRAINED GASES XE-133 CURIES O.OOE+00 0.OOE+00 2.30E-05 1.06E-03 XE-135 CURIES 0.OOE+00 0.OOE+00 O.OOE+00 3.39E-06 TOTALS I
CURIES 0.OOE+00 I O.OOE+00 I 2.30E-05 O
1.06E-03 I
_-ALP_
__UR___E__
_____0 ________________________
G-ALPHA I
CURIES I 0.00E+00 I 0.00E+00 I 0.00E+00 I 0.00E+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
16
TABLE 1-2B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 2 Starting 1-Jul-2005 Ending : 31-Dec-2005 I CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT lQUARTER 3 lQUARTER 4 lQUARTER 3 lQUARTER 4 l H-3 I
CURIES I 0.OOE+00 0.OOE+00 I 1.90E+02 I 5.92E+01 I FISSION & ACTIVATION PRODUCTS AG-llOM CURIES 0.OOE+00 l 0.OOE+00 l 9.04E-04 1.53E-04 l CD-115 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 1.29E-06 CO-57 l CURIES 0.OOE+00 l 0.OOE+00 7.12E-06 0.OOE+00 l CO-58 l CURIES l 0.OOE+00 0.OOE+00 6.21E-04 3.81E-03 CO-60 CURIES O.OOE+00 l 0.OOE+00 8.72E-03 3.14E-03 CR-51 l CURIES l 0.OOE+00 l 0.OOE+00 l 3.05E-05 1.47E-03 CS-137 CURIES 0.OOE+00 l 0.OOE+00 l 2.55E-05 9.96E-06 CS-138 l CURIES l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 2.44E-06 FE-55 CURIES l 0.00E+00 0.OOE+00 2.02E-03 1.57E-03 FE-59 l CURIES l 0.OOE+00 0.OOE+00 0.OOE+00 6.42E-05 l I-132 l CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 1.32E-05 l I-133 CURIES O.OOE+00 l 0.00E+00 l O.OOE+00 l 5.42E-06 IN-115M l CURIES l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 1.34E-06 l MN-54 CURIES l 0.OOE+00 0.OOE+00 1.16E-04 l 1.05E-04 l NB-95 CURIES 0.OOE+00 l 0.00E+00 l 3.35E-05 l 4.39E-04 l NB-97 CURIES 0.OOE+00 l 0.OOE+00 l 1.06E-04 6.47E-05 l ND-147 l CURIES l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 2.06E-06 l NI-56 l CURIES l o.OOE+00 l 0.OOE+00 6.47E-07 0.OOE+00 l PR-144 CURIES l0.OOE+00 l0.OOE+00 l 0.OOE+00 1.41E-03 l RH-105 j CURIES l 0.OOE+00 l 0.OOE+00 0.OOE+00 8.22E-05 l RU-105 l CURIES l 0.OOE+00 l 0.OOE+00 0.OOE+00 3.34E-05 l SB-122 CURIES 0.OOE+00 O.OOE+00 l 0.OOE+00 4.72E-05 SB-124 CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 3.33E-04 l SB-125 CURIES 0.OOE+00 l 0.OOE+00 4.44E-04 2.62E-03 l SN-113 l CURIES 0.OOE+00 l 0.OOE+00 0.OOE+00 1.05E-06 l SN-117M CURIES 0.OOE+00 l 0.OOE+00 1.51E-06 7.47E-05 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
17
TABLE 1-2B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: 2 Starting : 1-Jul-2005 Ending : 31-Dec-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT lQUARTER 3 lQUARTER 4 lQUARTER 3 lQUARTER 4 l FISSION & ACTIVATION PRODUCTS SR-85 CURIES 0.OOE+00 l 0.OOE+00 1.66E-06 l 2.03E-06 l SR-89 CURIES 4.40E-05 o0.OE+00 l 0.OOE+00 l 0.OOE+00 SR-90 l CURIES 0.OOE+00 l 0.OOE+00 l 9.76E-06 2.42E-13 l SR-92 CURIES 0.OOE+00 l 0.OOE+00 l 2.07E-05 l 9.79E-07 l TC-101 CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 9.59E-07 TC-99M CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 3.22E-05 l TE-125M CURIES 0.ooE+00 0.OOE+00 3.88E-02 1.26E-02 TE-129 CURIES 0.OOE+00 0.OOE+00 l 0.OOE+00 1.60E-05 TE-129M l CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 1.81E-04 l TE-132 l CURIES 0.OOE+00 0.OOE+00 l 0.OOE+00 l 5.14E-06 l Y-93 CURIES 0.OOE+00 O.OOE+00 l 1.40E-05 l 0.OOE+00 ZN-65 CURIES 0.OOE+00 0.OOE+00 l 3.02E-03 l 2.58E-03 l ZR-95 CURIES 0.OOE+00 0.OOE+00 l 1.62E-05 l 2.18E-04 l TOTALS I
CURIES I 4.40E-05 0.OOE+00 I 5.49E-02 I 3.10E-02 I DISSOLVED AND ENTRAINED GASES AR-41 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 l l.llE-06 KR-85 l CURIES 0.OOE+00 0.OOE+00 l 3.79E-04 4.50E-04 l XE-133 l CURIES 0.OOE+00 0.OOE+00 8.59E-04 l 1.40E-04 l XE-135 l CURIES 0.OOE+00 l 0.OOE+00 l 1.32E-05 l 6.44E-07 XE-137 CURIES l0.OE+00 0.OOE+00 l 9.17E-05 l 0.OOE+00 TOTALS I
CURIES I O.OOE+00 I O.OOE+00 I 1.34E-03 I 5.92E-04 I G-ALPHA I
CURIES I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 0.00E+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
18
TABLE 1-2C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: Site Starting :
-Jan-2005 Ending : 30-Jun-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT IQUARTER 1 lQUARTER 2 lQUARTER 1 lQUARTER 2 l H-3 I
CURIES I 0.OOE+00 0.OOE+00 I 1.70E+02 I 6.53E+02 I FISSION & ACTIVATION PRODUCTS AG-llOM CURIES l 0.OOE+00 0.OOE+00 l 8.13E-06 2.19E-05 BE-7 l CURIES 0.OOE+00 0.OOE+00 4.06E-06 l 0.OOE+00 CO-57 CURIES l O.OOE+00 0.OOE+00 l 0.OOE+00 l 4.01E-07 CO-58 l CURIES l 0.OOE+00 l O.OOE+00 l 3.89E-04 2.48E-04 CO-60 l CURIES l 0.OOE+00 l O.OOE+00 7.34E-04 l 1.50E-03 CR-51 CURIES l 0.OOE+00 0.OOE+00 l 1.43E-05 l 1.58E-05 CS-134 CURIES l 0.OOE+00 0.OOE+00 l 0.OOE+00 4.30E-06 CS-137 CURIES l 0.OOE+00 0.OOE+00 l 6.45E-05 1.62E-04 FE-55 j CURIES 0.OOE+00 l0.OOE+00 l 6.30E-04 l 4.56E-04 MN-54 CURIES l O.OOE+00 l 0.OOE+00 l 5.58E-06 3.73E-06 NB-95 CURIES l O.OOE+00 0.OOE+00 l 8.31E-05 2.10E-05 NB-97 l CURIES l 0.OOE+00 0.OOE+00 l 3.73E-05 l 7.85E-05 PR-144 CURIES O.OOE+00 0.OOE+00 l 7.54E-05 0.OOE+00 SB-125 CURIES l 0.OOE+00 l 0.OOE+00 l 9.51E-06 l 0.OOE+00 SN-113 l CURIES l 0.OOE+00 l O.OOE+00 l 0.OOE+00 l 9.85E-07 SN-117M CURIES 0.OOE+00 0.OOE+00 5.91E-05 3.82E-05 SR-89 l CURIES l 5.09E-11 l 2.09E-03 3.87E-08 l 1.05E-05 SR-90 CURIES l 0.OOE+00 l 0.OOE+00 l 4.57E-06 l 2.46E-04 TC-101 l CURIES l 0.OOE+00 l 0.OOE+00 l 1.04E-06 l 1.75E-06 TE-125M l CURIES 0.OOE+00 l 0.00E+00 j 1.47E-02 l 5.68E-02 ZN-65 CURIES l O.OOE+00 l 0.OOE+00 l 5.96E-04 5.30E-04 ZR-95 CURIES l 0.OOE+00 0.OOE+00 l 2.73E-05 3.07E-06 TOTALS I
CURIES I 5.09E-11 I 2.09E-03 I 1.74E-02 I 6.01E-02 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
19
TABLE 1-2C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: Site Starting :
1-Jan-2005 Ending : 30-Jun-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT IQUARTER 1 IQUARTER 2 IQUARTER 1 IQUARTER 2 l DISSOLVED AND ENTRAINED GASES XE-131M CURIES 0.00E+00 0.OOE+00 2.49E-05 l.19E-05 XE-133 CURIES 0.OOE+00 0.OOE+00 3.52E-05 2.15E-03 XE-133M CURIES 0.OOE+00 0.OOE+00 l 0.OOE+00 5.24E-06 XE-135 CURIES 0.OOE+00 0.OOE+00 O.OOE+00 4.70E-06 TOTALS I
CURIES 0.OOE+00 0.OOE+00 I 6.OOE-05 I 2.17E-03 I G-ALPHA I
CURIES I 0.OOE+00 I O.OOE+00 I 0.OOE+00 I O.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
20
TABLE 1-2C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents Unit: Site Starting 1-Jul-2005 Ending : 31-Dec-2005 l CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT lQUARTER 3 lQUARTER 4 lQUARTER 3 lQUARTER 4 I H-3 l CURIES I 0.00E+00 0.OOE+00 I 3.01E+02 I 1.91E+02 I FISSION & ACTIVATION PRODUCTS AG-llOM CD-115 CO-57 CO-58 CO-60 CR-51 CS-134 CS-137 CS-138 FE-55 FE-59 I-130 I-131 I-132 I-133 I-135 IN-115M MN-54 MO-99 NB-95 NB-97 ND-147 NI-56 PR-144 RH-105 RU-105 SB-122 SB-124 SB-125 SN-113 CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES CURIES 0.0OE+00
- 0. OOE+00
- 0. OOE+00 l.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 l 0.OOE+00
- 0. 00E+00 0.OOE+00 0.OOE+00 l 0.OOE+00 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 0.O0E+00 0.00E+00 l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 0.OOE+00 l 0.OOE+00 l 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 1.55E-03
- 0. OOE+00 8.05E-06 8.11E-04 1.24E-02 3.05E-05 7.60E-07 1.56E-04 0.OOE+00 3.51E-03
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.0OE+00 0.OOE+00 1.59E-04 0.OOE+00 3.35E-05 1.33E-04 0.OOE+00 6.47E-07 0.OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 6.31E-04 0.OOE+00
- 2. OOE-04 1.29E-06
- 0. OOE+00
- 6. 02E-03 4.63E-03 1.60E-03
- 0. OOE+00 5.OOE-05 6.36E-06
- 3. 08E-03
- 1. 51E-04
- 2. 07E-06 5.34E-05 1.32E-05 9.20E-05 6.38E-06 1.34E-06 2.21E-04 2.36E-05
- 4. 80E-04 8.25E-05 2.06E-06 1.64E-06 1.41E-03 8.22E-05 4.37E-05 4.72E-05 4.11E-04 4.24E-03 1.05E-06 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
21
TABLE 1-2C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2005 Liquid Effluents Unit: Site Starting :
1-Jul-2005 Ending : 31-Dec-2005 I CONTINUOUS MODE I
BATCH MODE I
NUCLIDE I
UNIT lQUARTER 3 lQUARTER 4 IQUARTER 3 IQUARTER 4 l FISSION & ACTIVATION PRODUCTS SN-117M CURIES 0.00E+00 0.OOE+00 1.51E-06 9.66E-05 l SR-85 l CURIES 0.OOE+00 l 0.OOE+00 l 1.66E-06 l 2.95E-06 SR-89 l CURIES l 8.78E-05 0.OOE+00 2.05E-12 1.94E-05 l SR-90 CURIES 0.OOE+00 l 0.OOE+00 9.76E-06 2.42E-13 l SR-92 l CURIES l 0.OOE+00 l 0.OOE+00 l 4.51E-05 9.79E-07 TC-101 l CURIES l 0.00E+00 l 0.OOE+00 l 0.OOE+00 l 9.59E-07 l TC-99M l CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 1.07E-04 TE-125M l CURIES l 0.OOE+00 l 0.OOE+00 l 5.28E-02 1.97E-02 l TE-129 l CURIES l 0.OOE+00 0.OOE+00 l 0.OOE+00 l 1.60E-05 TE-129M l CURIES l 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 1.81E-04 TE-132 l CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 l 5.14E-06 TE-134 CURIES 0.00E+00 0.OOE+00 l 0.OOE+00 l 1.07E-05 Y-92 CURIES 0.OOE+00 l 0.OOE+00 7.04E-06 0.00E+00 l Y-93 CURIES l 0.OOE+00 0.OOE+00 l 1.40E-05 l 0.OOE+00 l ZN-65 l CURIES l 0.OOE+00 0.OOE+00 4.55E-03 l 3.76E-03 l ZR-95 l CURIES 0.OOE+00 0.OOE+00 l 1.62E-05 2.33E-04 l TOTALS I CURIES I 8.78E-05 I 0.OOE+00 I 7.69E-02 I 4.71E-02 I DISSOLVED AND ENTRAINED GASES AR-41 CURIES l 0.OOE+00 l 0.OOE+00 0.OOE+00 l 4.90E-06 l KR-85 l CURIES l 0.OOE+00 0.OOE+00 3.79E-04 6.52E-04 XE-133 l CURIES 0.OOE+00 l 0.OOE+00 l 1.10E-03 7.15E-04 XE-135 l CURIES l 0.OOE+00 l 0.OOE+00 l 1.92E-05 9.64E-06 XE-137 l CURIES l 0.OOE+00 l 0.OOE+00 l 9.17E-05 l 0.00E+00 TOTALS I
CURIES I 0.OOE+00 I 0.OOE+00 I 1.59E-03 I 1.38E-03 I G-ALPHA I
CURIES I O.OOE+00 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 1-4 for typically achieved minimum detectable concentrations.
22
TABLE 1-3A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 1 Starting: 01-Jan-2005 Ending: 30-Jun-2005 Cumulative Doses per Quarter Organ ODCM Units Quarter s of Quarter
% of Limit 1
ODCM 2
ODCM Limit Limit Bone 5.0 mrem 1.73E-03 3.47E-02 1.04E-02 2.09E-01 Liver 5.0 mrem 1.09E-03 2.18E-02 4.37E-03 8.74E-02 TBody 1.5 mrem 6.97E-04 4.65E-02 3.92E-03 2.61E-01 Thyroid 5.0 mrem 8.47E-04 1.69E-02 3.75E-03 7.50E-02 Kidney 5.0 mrem 6.79E-03 1.36E-01 2.52E-02 5.04E-01 Lung 5.0 mrem 4.38E-04 8.76E-03 2.08E-03 4.16E-02 GILLI 5.0 mrem 6.83E-03 1.37E-01 2.51E-02 5.02E-01 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 10.0 mrem 1.22E-02 1.22E-01 Liver 10.0 mrem 5.46E-03 5.46E-02 TBody 3.0 mrem 4.62E-03 1.54E-01 Thyroid 10.0 mrem 4.60E-03 4.60E-02 Kidney 10.0 mrem 3.20E-02 3.20E-01 Lung 10.0 mrem 2.52E-03 2.52E-02 GILLI 10.0 mrem 3.19E-02 3.19E-01 23
TABLE 1-3A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 1 Starting: 01-Jul-2005 Ending: 31-Dec-2005 Cumulative Doses per Quarter Organ ODCM Units Quarter
% of Quarter
% of Limit 3
ODCM 4
ODCM Limit Limit Bone 5.0 mrem 5.18E-03 1.04E-01 2.86E-03 5.72E-02 Liver 5.0 mrem 3.01E-03 6.03E-02 2.26E-03 4.52E-02 TBody 1.5 mrem 1.72E-03 1.15E-01 1.50E-03 1.OOE-01 Thyroid 5.0 mrem 2.16E-03 4.31E-02 1.82E-03 3.65E-02 Kidney 5.0 mrem 2.OOE-02 4.01E-01 1.07E-02 2.15E-01 Lung 5.0 mrem 1.70E-03 3.40E-02 9.22E-03 1.84E-01 GILLI 5.0 mrem 2.07E-02 4.15E-01 1.23E-02 2.45E-01 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 10.0 mrem 2.02E-02 2.02E-01 Liver 10.0 mrem 1.07E-02 1.07E-01 TBody 3.0 mrem 7.84E-03 2.61E-01 Thyroid 10.0 mrem 8.58E-03 8.58E-02 Kidney 10.0 mrem 6.28E-02 6.28E-01 Lung 10.0 mrem 1.34E-02 1.34E-01 GILLI 10.0 mrem 6.49E-02 6.49E-01 24
TABLE 1-3B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 2 Starting: 01-Jan-2005 Ending: 30-Jun-2005 Cumulative Doses per Quarter Organ ODCM Units Quarter
% of Quarter
% of Limit 1
ODCM 2
ODCM Limit Limit Bone 5.0 mrem 4.67E-03 9.34E-02 1.46E-02 2.93E-01 Liver 5.0 mrem 2.75E-03 5.50E-02 7.65E-03 1.53E-01 TBody 1.5 mrem 1.64E-03 1.09E-01 4.42E-03 2.95E-01 Thyroid 5.0 mrem 2.33E-03 4.66E-02 6.67E-03 1.33E-01 Kidney 5.0 mrem 1.94E-02 3.88E-01 5.96E-02 l.19E+00 Lung 5.0 mrem 1.02E-03 2.03E-02 2.48E-03 4.95E-02 GILLI 5.0 mrem 1.92E-02 3.84E-01 5.88E-02 1.18E+00 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 10.0 mrem 1.93E-02 1.93E-01 Liver 10.0 mrem 1.04E-02 1.04E-01 TBody 3.0 mrem 6.06E-03 2.02E-01 Thyroid 10.0 mrem 9.OOE-03 9.00E-02 Kidney 10.0 mrem 7.90E-02 7.90E-01 Lung 10.0 mrem 3.49E-03 3.49E-02 GILLI 10.0 mrem 7.80E-02 7.80E-01 25
TABLE 1-3B Joseph M. Parley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO LIQUID RELEASES Unit: 2 Starting: 01-Jul-2005 Ending: 31-Dec-2005 Cumulative Doses per Quarter Organ ODCM Units Quarter
% of Quarter
% of Limit 3
ODCM 4
ODCM Limit Limit Bone 5.0 mrem 1.40E-02 2.80E-01 5.97E-03 l.19E-01 Liver 5.0 mrem 6.83E-03 1.37E-01 3.01E-03 6.03E-02 TBody 1.5 mrem 3.61E-03 2.41E-01 1.55E-03 1.03E-01 Thyroid 5.0 mrem 5.29E-03 1.06E-01 2.06E-03 4.11E-02 Kidney 5.0 mrem 5.56E-02 l.llE+00 2.25E-02 4.51E-01 Lung 5.0 mrem 3.43E-03 6.85E-02 1.48E-02 2.97E-01 GILLI 5.0 mrem 5.72E-02 1.14E+00 2.60E-02 5.20E-01 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 10.0 mrem 3.93E-02 3.93E-01 Liver 10.0 mrem 2.02E-02 2.02E-01 TBody 3.0 mrem 1.12E-02 3.74E-01 Thyroid 10.0 mrem 1.63E-02 1.63E-01 Kidney 10.0 mrem 1.57E-01 1.57E+00 Lung 10.0 mrem 2.18E-02 2.18E-01 GILLI 10.0 mrem 1.61E-01 1.61E+00 26
TABLE 1-4 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 MINIMUM DETECTABLE CONCENTRATION -
LIQUID SAMPLE ANALYSES The values in this table represent a priori Minimum Detectable Concentrations (MDC) that are typically achieved in laboratory analyses of liquid radwaste samples.
Nuclide MDC(uCi/ML)
MN-54 3.14E-08 CO-58 4.92E-08 FE-59 7.19E-08 CO-60 4.77E-08 ZN-65 8.11E-08 MO-99 1.29E-07 I-131 2.53E-08 CS-134 3.51E-08 CS-137 4.28E-08 CE-141 5.41E-08 CE-144 1.95E-07 27
TABLE 1-5A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Batch Release Summary Unit: 1 Starting :
1-Jan-2005 Ending : 30-Jun-2005 LIQUID RELEASES NUMBER OF BATCH RELEASES TOTAL TIME PERIOD FOR BATCH RELEASES MAXIMUM TIME PERIOD FOR A BATCH RELEASE AVERAGE TIME PERIOD FOR BATCH RELEASES MINIMUM TIME PERIOD FOR A BATCH RELEASE AVERAGE STREAM FLOW DURING PERIODS OF RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :
96 8702.00 125.00
- 90. 65 71.00 MINUTES MINUTES MINUTES MINUTES 1.41E+04 CFS *
- Average River Flow Rate, taken at Walter F. George Lock and Dam, located 30.7 miles above Farley Nuclear Plant.
28
TABLE 1-5A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Batch Release Summary Unit: 1 Starting :
I-Jul-2005 Ending : 31-Dec-2005 LIQUID RELEASES NUMBER OF BATCH RELEASES 164 TOTAL TIME PERIOD FOR BATCH RELEASES 15235.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE 115.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 92.90 MINUTES MINIMUM TIME PERIOD FOR A BATCH RELEASE 66.00 MINUTES AVERAGE STREAM FLOW DURING PERIODS OF RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :
9.69E+03 CFS *
- Average River Flow Rate, taken at Walter F. George Lock and Dam, located 30.7 miles above Farley Nuclear Plant.
29
TABLE 1-5B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Batch Release Summary Unit: 2 Starting :
l-Jan-2005 Ending : 30-Jun-2005 LIQUID RELEASES NUMBER OF BATCH RELEASES 146 TOTAL TIME PERIOD FOR BATCH RELEASES 14959.50 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE 150.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 102.46 MINUTES MINIMUM TIME PERIOD FOR A BATCH RELEASE 4.00 MINUTES AVERAGE STREAM FLOW DURING PERIODS OF RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :
1.41E+04 CFS *
- Average River Flow Rate, taken at Walter F. George Lock and Dam, located 30.7 miles above Farley Nuclear Plant.
30
TABLE 1-5B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Batch Release Summary Unit: 2 Starting :
1-Jul-2005 Ending : 31-Dec-2005 LIQUID RELEASES NUMBER OF BATCH RELEASES TOTAL TIME PERIOD FOR BATCH RELEASES MAXIMUM TIME PERIOD FOR A BATCH RELEASE AVERAGE TIME PERIOD FOR BATCH RELEASES MINIMUM TIME PERIOD FOR A BATCH RELEASE AVERAGE STREAM FLOW DURING PERIODS OF RELEASE OF LIQUID EFFLUENT INTO A FLOWING STREAM :
235 24359.00 121.00 103.66 67.00 MINUTES MINUTES MINUTES MINUTES 9.69E+03 CFS *
- Average River Flow Rate, taken at Walter F. George Lock and Dam, located 30.7 miles above Farley Nuclear Plant.
31
TABLE 1-6A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Abnormal Release Summary Unit: 1 Starting :
1-Jan-2005 Ending : 30-Jun-2005 LIQUID RELEASES NUMBER OF RELEASES TOTAL TIME FOR ALL MAXIMUM TIME FOR A AVERAGE TIME FOR A MINIMUM TIME FOR A TOTAL ACTIVITY FOR RELEASES RELEASE RELEASE RELEASE ALL RELEASES :
0 0.00 MINUTES 0.00 MINUTES 0.00 MINUTES 0.00 MINUTES 0.00E+00 CURIES 32
TABLE 1-6A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents - Abnormal Release Summary Unit: 1 Starting :
1-Jul-2005 Ending : 31-Dec-2005 LIQUID RELEASES NUMBER OF RELEASES 0
TOTAL TIME FOR ALL RELEASES 0.00 MINUTES MAXIMUM TIME FOR A RELEASE 0.00 MINUTES AVERAGE TIME FOR A RELEASE 0.00 MINUTES MINIMUM TIME FOR A RELEASE 0.00 MINUTES TOTAL ACTIVITY FOR ALL RELEASES O.OOE+00 CURIES 33
TABLE 1-6B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents - Abnormal Release Summary Unit: 2 Starting :
1-Jan-2005 Ending : 30-Jun-2005 LIQUID RELEASES NUMBER OF RELEASES 0
TOTAL TIME FOR ALL RELEASES 0.00 MINUTES MAXIMUM TIME FOR A RELEASE 0.00 MINUTES AVERAGE TIME FOR A RELEASE 0.00 MINUTES MINIMUM TIME FOR A RELEASE 0.00 MINUTES TOTAL ACTIVITY FOR ALL RELEASES :
0.OOE+00 CURIES 34
TABLE 1-6B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Liquid Effluents -
Abnormal Release Summary Unit: 2 Starting :
1-Jul-2005 Ending : 31-Dec-2005 LIQUID RELEASES NUMBER OF RELEASES 1
TOTAL TIME FOR ALL RELEASES 90.00 MINUTES MAXIMUM TIME FOR A RELEASE 90.00 MINUTES AVERAGE TIME FOR A RELEASE 90.00 MINUTES MINIMUM TIME FOR A RELEASE 90.00 MINUTES TOTAL ACTIVITY FOR ALL RELEASES :
8.81E-08 CURIES 35
2.0 GASEOUS EFFLUENTS This section contains applicable ODCM limits for gaseous effluents as well as the quantities of radioactive gaseous effluents released during 2005. These quantities are summarized on a quarterly basis and include any unplanned releases. Tabulations are provided of the offsite air doses calculated in accordance with ODCM 3.4.2 to show conformance with the limits of ODCM 3.1.3, and the offsite organ doses to a member of the public calculated in accordance with ODCM 3.4.3 to show conformance with ODCM 3.1.4.
2.1 Regulatory Requirements The requirements presented in this section are for Unit 1 and Unit 2.
2.1.1 Dose Rate Limits The dose rates due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY shall be limited to the following:
- a. For noble gases: Less than or equal to 500 mrem/yr. to the whole body and less than or equal to 3000 mrem/yr. to the skin, and
- b. For Iodine-131, Iodine-133,tritium and for all radionuclides in particulate form with half-lives greater than 8 days: Less than or equal to 1500 mrem/yr. to any organ.
2.1.2 Air Doses Due to Noble Gases in Gaseous Releases Technical Specifications 5.5.4.e and 5.5.4.h state that the air dose due to noble gases released in gaseous effluents, from each reactor unit, to areas at and beyond the SITE BOUNDARY (see ODCM Figure 10-1) shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and
- b. During any calendar year: Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.
36
2.1.3 Doses to a Member of the Public Technical Specifications 5.5.4.e and 5.5.4.i state that the dose to a MEMBER OF THE PUBLIC from I-131, I-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each reactor unit, to areas at and beyond the SITE BOUNDARY (see ODCM Figure 10-1) shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 7.5 mrem to any organ, and
- b. During any calendar year: Less than or equal to 15 mrem to any organ.
2.2 Measurements and Approximation of Total Radioactivity The following noble gases are considered in evaluating gaseous effluents:
KR-87 XE-133 KR-88 XE-135 XE-133M XE-138 The following radioiodines and radioactive materials in particulate form are specifically considered in evaluating gaseous effluents:
MN-54 MO-99 FE-59 I-131 CO-58 CS-134 CO-60 CS-137 ZN-65 CE-141 SR-89 CE-144 SR-90 H-3 2.2.1 Sample collection and Analysis Periodic grab samples from plant effluent streams are analyzed by a computerized pulse height analyzer system utilizing high resolution germanium detectors. Samples are obtained and analyzed in accordance with ODCM Table 3-3. Isotopic values thus obtained are used for release rate calculations as specified in ODCM 3.4.2 and ODCM 3.4.3. Only those nuclides which are detected are used in calculations. For radioiodines and particulates, in addition to the nuclides listed above other nuclides with half-lives greater than 8 days which are identified are also considered.
Continuous Releases: Continuous sampling is performed on the continuous release points (i.e. the Plant Vent Stack, Containment Purge, and the Turbine Building Vent). Particulate material is collected by filtration. Periodically these filters are removed and analyzed on the pulse height analyzer to identify and quantify radioactive materials collected on the filters. Particulate filters 37
are then analyzed for gross alpha and strontium as required. All gross alpha, Sr-89 and SR-90 samples are sent offsite to the Georgia Power Environmental Laboratory for analysis.
Batch Releases: The processing of batch type releases (from Containment or Waste Gas Decay Tanks) is analogous to continuous releases, except that the release is not commenced until samples have been obtained and analyzed.
Typically achieved minimum detectable concentrations for gaseous effluent sample analyses are reported in Table 2-6.
2.2.2 Total Quantities of Radioactivity, Dose Rates, and Cumulative Doses The methods for determining release quantities of radioactivity, dose rates, and cumulative doses follow:
2.2.2.1 Fission and Activation Gases The released radioactivity is determined using sample analyses results collected as described in section 2.2.1 and the average release flow rates over the period represented by the collected sample.
Dose rates due to noble gases, radioiodines, tritium, and particulates are calculated (with computer assistance). The calculated dose rates are compared to the dose rate limits specified in ODCM 3.1.2 for noble gases, radioiodine, tritium, and particulates. Dose rate calculation methodology is presented in the ODCM.
Beta and gamma air doses due to noble gases are calculated for the location in the unrestricted area with the potential for the highest exposure due to gaseous releases. Air doses are calculated for each release period and cumulative totals are kept for each unit for the calendar quarter and year. Cumulative air doses are compared to the dose limits specified in ODCM 3.1.3.
The current percent of the ODCM limits are shown on the printout for each release period. Air dose calculation methodology is presented in the ODCM.
2.2.2.2 Radioiodine, Tritium, and Particulate Releases Released quantities of radioiodines are determined using the weekly samples and release flow rates for the six routine release points. Radioiodine concentrations are determined by gamma spectroscopy.
Release quantities of particulates are determined using the weekly (filter) samples and release flow rates for the six routine release points. Gamma spectroscopy is used to quantify concentrations of principal gamma emitters.
38
After each quarter, the particulate filters from each applicable vent (plant vent stack and containment purge) are combined, fused, and a strontium separation is performed. Since sample flows and vent flows are almost constant over each quarterly period the filters from each vent can be dissolved together.
Decay corrections are performed back to the middle of the quarterly collection period. If Sr-89 or Sr-90 is not detected, MDC's are calculated. Strontium concentrations are input into the composite file of the computer and used for release dose rate and individual dose calculations.
Tritium samples are obtained monthly from each vent (with the exception of containment purge, which is sampled weekly) by passing the sample stream through a cold trap or by using the bubble method. The grams of water vapor/cubic meter is measured upstream of the cold trap in order to alleviate the difficulties in determining water vapor collection efficiencies. The tritium samples are analyzed onsite and the results furnished in uCi/ml of water. The tritium concentration in water is converted to the tritium concentration in air and this value is input into the composite file of the computer and used in release, dose rate, and individual dose calculations.
Dose rates due to radioiodine, tritium and particulates are calculated for a hypothetical child exposed to the inhalation pathway at the location in the unrestricted area where the potential dose rate is expected to be the highest. Dose rates are calculated, for each release point for each release period, and the dose rates from each release point is compared to the dose rate limits specified in ODCM 3.1.2, allocated for each release point as described in ODCM 3.3.2.
Doses to a Member of the Public (individual doses) due to radioiodine, tritium and particulates are calculated for the controlling receptor, which is described in the ODCM. Individual doses are calculated for each release period, and cumulative totals are kept for each unit, for the current calendar quarter and year. Cumulative individual doses are compared to the dose limits specified in ODCM 3.1.4. The current percent of ODCM limits are shown on the printout for each release period.
2.2.2.3 Gross Alpha Release The gross alpha release is computed each month by counting the particulate filters, for each week for gross alpha activity in a proportional counter. The highest concentration calculated for any of these weeks is used for the monthly value. This value is input into the composite file of the computer and used for release calculations.
39
2.2.3 Total Error Estimation The maximum errors associated with monitor readings, sample flow, vent flow, sample collection, monitor calibration and laboratory procedure are collectively estimated to be:
Fission and Activation Gases Iodine Particulates Tritium 75%
60%
50%
45%
The average error associated with counting is estimated to be:
Fission and Activation Gases Iodine Particulates Tritium 19%
28%
20%
8%
2.3 Gaseous Effluent Release Data Regulatory Guide 1.21 Tables lA, 1B and 1C are found in this report as Tables 2-1A, 2-1B, 2-1C, 2-2A, 2-2B, 2-2C, 2-3A, 2-3B, and 2-3C. Data are presented on a quarterly basis as required by Regulatory Guide 1.21.
To complete Tables 2-1A and 2-1B, the total release for each of the four categories (fission and activation gases, radioiodines, particulates and tritium) was divided by the number of seconds in the quarter to obtain a release rate in uCi/second for each category. However, the percent of the ODCM limits are not applicable because FNP has no curie limit for gaseous releases.
Applicable limits are expressed in terms of dose. Noble gases are limited as specified in ODCM 3.1.2. The other three categories (tritium, radioiodines, and particulates) are limited as a group as specified in ODCM 3.1.2.
Dose rates due to noble gas releases and due to radioiodines, tritium and particulate releases were calculated as part of the pre-release and post-release permits. No limits were exceeded for this reporting period.
Gross alpha radioactivity is reported in Tables 2-1A, 2-1B and 2-1C as curies released in each quarter.
Limits for cumulative beta and gamma air doses due to noble gases are presented in Tables 2-4A and 2-4B along with the percent of ODCM limits.
Limits for cumulative doses to an individual due to radioiodines, tritium and particulates are specified in ODCM 3.1.4. Cumulative individual doses are presented in Tables 2-5A and 2-5B along with percent of ODCM limits.
40
2.4 Radiological Impact Due to Gaseous Releases The air doses due to noble gases and doses to a Member of the Public due to radioiodines, tritium and particulates in gaseous effluents for Units 1 and 2 are provided in the following tables in order to show conformance with the limits of ODCM 3.1.3 and ODCM 3.1.4:
Unit 1 2005 Air Doses Due to Noble Gases in Gaseous Releases: Table 2-4A Unit 2 2005 Air Doses Due to Noble Gases in Gaseous Releases: Table 2-4B Unit 1 2005 Doses to Due to Radioiodines, in Gaseous Releases:
Unit 2 2005 Doses to Due to Radioiodines, in Gaseous Releases:
a Member of the Public Tritium, and Particulates Table 2-5A a Member of the Public Tritium, and Particulates Table 2-5B 2.5 Gaseous Effluents - Batch Releases Batch release information for Units 1 and 2 is following tables:
summarized in the Unit 1 2005 Gaseous Effluents - Batch Release Summary: Table 2-7A Unit 2 2005 Gaseous Effluents - Batch Release Summary: Table 2-7B 2.6 Gaseous Effluents - Abnormal Releases There were no abnormal releases on Unit 1 or Unit 2 during 2005.
Abnormal release information for Units 1 and 2 is the following tables:
summarized in Unit 1 2005 Gaseous Effluents - Abnormal Release Summary: Table 2-8A Unit 2 2005 Gaseous Effluents - Abnormal Release Summary: Table 2-8B 41
TABLE 2-1A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Summation of All Releases Unit: 1 Starting :
1-Jan-2005 Ending : 30-Jun-2005 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE CURIES 1.47E+01 2.32E+01 7.74E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.89E+00 2.95E+00
- 3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
- 1. TOTAL IODINE-131 CURIES 3.36E-07 0.OOE+00 6.62E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 4.32E-08 0.OOE+00
- 3. PERCENT OF APPLICABLE LIMIT C. PARTICULATES
- 1. PARTICULATES(HALF-LIVES>8 DAYS)
CURIES 0.OOE+00 0.OOE+00 5.39E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 0.OOE+00 0.OOE+00
- 3. PERCENT OF APPLICABLE LIMIT
- 4. GROSS ALPHA RADIOACTIVITY CURIES 9.82E-08 5.OOE-09 D. TRITIUM
- 1. TOTAL RELEASE CURIES 2.59E+00 1.90E+00 4.57E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 3.33E-01 2.42E-01
- 3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.
See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.
42
TABLE 2-1A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Summation of All Releases Unit: 1 Starting :
1-Jul-2005 Ending : 31-Dec-2005 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE CURIES 8.71E+00 3.40E+01 7.74E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.10E+00 4.28E+00
- 3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
- 1. TOTAL IODINE-131 CURIES 0.OOE+00 0.OOE+00 6.62E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 0.OOE+00 0.OOE+00
- 3. PERCENT OF APPLICABLE LIMIT C. PARTICULATES
- 1. PARTICULATES(HALF-LIVES>8 DAYS)
CURIES 3.73E-08 2.67E-07 5.39E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 4.70E-09 3.36E-08
- 3. PERCENT OF APPLICABLE LIMIT
- 4. GROSS ALPHA RADIOACTIVITY CURIES 1.54E-08 0.OOE+00 D. TRITIUM
- 1. TOTAL RELEASE CURIES 1.62E+00 4.05E+00 4.57E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 2.04E-01 5.10E-01
- 3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.
See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.
43
TABLE 2-1B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Summation of All Releases Unit: 2 Starting :
l-Jan-2005 Ending : 30-Jun-2005 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE CURIES 5.02E+00 7.30E+00 7.74E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 6.46E-01 9.29E-01
- 3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
- 1. TOTAL IODINE-131 CURIES 0.OOE+00 0.OOE+00 6.62E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 0.OOE+00 0.OOE+00
- 3. PERCENT OF APPLICABLE LIMIT C. PARTICULATES
- 1. PARTICULATES(HALF-LIVES>8 DAYS)
CURIES 0.OOE+00 0.OOE+00 5.39E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 0.OOE+00 0.OOE+00
- 3. PERCENT OF APPLICABLE LIMIT
- 4. GROSS ALPHA RADIOACTIVITY CURIES 2.45E-14 3.77E-08 D. TRITIUM
- 1. TOTAL RELEASE CURIES 3.67E+00 5.29E+00 4.57E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 4.72E-01 6.73E-01
- 3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.
See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.
44
TABLE 2-1B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Summation of All Releases Unit: 2 Starting :
1-Jul-2005 Ending : 31-Dec-2005 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR
- A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE CURIES 6.49E+00 2.27E+00 7.74E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 8.17E-01 2.85E-01
- 3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
- 1. TOTAL IODINE-131 CURIES 0.OOE+00 4.27E-09 6.62E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 0.OOE+00 5.37E-10
- 3. PERCENT OF APPLICABLE LIMIT C. PARTICULATES
- 1. PARTICULATES(HALF-LIVES>8 DAYS)
CURIES 1.53E-07 7.46E-08 5.39E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 1.92E-08 9.38E-09
- 3. PERCENT OF APPLICABLE LIMIT
- 4. GROSS ALPHA RADIOACTIVITY CURIES 3.31E-08 0.OOE+00 D. TRITIUM
- 1. TOTAL RELEASE CURIES 4.97E+00 2.10E+00 4.57E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 6.25E-01 2.64E-01
- 3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.
See Tables 2-4A, 2-4B, 2-5A, and 2-SB of this report.
45
TABLE 2-1C Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Summation of All Releases Unit: Site Starting : 1-Jan-2005 Ending : 30-Jun-2005 TYPE OF EFFLUENT UNITS QUARTER 1 QUARTER 2 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE CURIES 1.97E+01 3.05E+01 7.74E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 2.54E+00 3.88E+00
- 3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
- 1. TOTAL IODINE-131 CURIES 3.36E-07 0.OOE+00 6.62E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 4.32E-08 0.OOE+00
- 3. PERCENT OF APPLICABLE LIMIT C. PARTICULATES
- 1. PARTICULATES(HALF-LIVES>8 DAYS)
CURIES O.OOE+00 0.OOE+00 5.39E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 0.OOE+00 0.OOE+00
- 3. PERCENT OF APPLICABLE LIMIT
- 4. GROSS ALPHA RADIOACTIVITY CURIES 9.82E-08 4.27E-08 D. TRITIUM
- 1. TOTAL RELEASE CURIES 6.26E+00 7.19E+00 4.57E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 8.05E-01 9.14E-01
- 3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.
See Tables 2-4A, 2-4B, 2-5A, and 2-5B of this report.
46
TABLE 2-1C Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Summation of All Releases Unit: Site Starting :
1-Jul-2005 Ending : 31-Dec-2005 TYPE OF EFFLUENT UNITS QUARTER 3 QUARTER 4 EST. TOT ERROR %
A. FISSION & ACTIVATION PRODUCTS
- 1. TOTAL RELEASE CURIES 1.52E+01 3.63E+01 7.74E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec l.91E+00 4.57E+00
- 3. PERCENT OF APPLICABLE LIMIT B. RADIOIODINES
- 1. TOTAL IODINE-131 CURIES 0.OOE+00 4.27E-09 6.62E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 0.OOE+00 5.37E-10
- 3. PERCENT OF APPLICABLE LIMIT C. PARTICULATES
- 1. PARTICULATES(HALF-LIVES>8 DAYS)
CURIES 1.90E-07 3.42E-07 5.39E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 2.39E-08 4.30E-08
- 3. PERCENT OF APPLICABLE LIMIT
- 4. GROSS ALPHA RADIOACTIVITY CURIES 4.85E-08 0.OOE+00 D. TRITIUM
- 1. TOTAL RELEASE CURIES 6.60E+00 6.15E+00 4.57E+01
- 2. AVERAGE RELEASE RATE FOR PERIOD uCi/Sec 8.30E-01 7.74E-01
- 3. PERCENT OF APPLICABLE LIMIT Applicable limits are expressed in terms of dose.
See Tables 2-4A, 2-4B, 2-SA, and 2-5B of this report.
47
TABLE 2-2A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Mixed-Mode Level Releases Unit: 1 Starting : 1-Jan-2005 Ending : 30-Jun-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 1 IQUARTER 2 IQUARTER 1 IQUARTER 2 l FISSION GASES AR-41 CURIES 1.47E+01 2.28E+01 0.OOE+00 0.OOE+00 XE-133 CURIES l0.OOE+00 3.54E-01 0.OOE+00 0.OOE+00 TOTAL FOR PERIOD I
CURIES I 1.47E+01 I 2.32E+01 0.OOE+00 0.OOE+00 I IODINES I-133 CURIES 1.17E-05 0.OOE+00 0.OOE+00 0.OOE+00 I-131 CURIES 3.36E-07 0.OOE+00 0.OOE+00 0.OOE+00 TOTAL FOR PERIOD I
CURIES I 1.20E-05 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES 0.OOE+00 I 0.OOE+00 j 0.OOE+00 0.OOE+00 I H-3 CURIES 2.59E+00 1.90E+00 0.OOE+00 0.OOE+00 G-ALPHA CURIES 9.82E-08 5.00E-09 0.OOE+00 0.OOE+00 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
48
TABLE 2-2A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Mixed-Mode Level Releases Unit: 1 Starting :
1-Jul-2005 Ending : 31-Dec-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT 1QUARTER 3 1QUARTER 4 IQUARTER 3 IQUARTER 4 l FISSION GASES AR-41 I
CURIES I 8.71E+00 I 3.40E+01 I 0.00E+00 I O.OOE+00 I TOTAL FOR PERIOD I
CURIES I 8.71E+00 I 3.40E+01 I O.0OE+00 I Q.OOE+00 I IODINES TOTAL FOR PERIOD I
CURIES 0.OOE+00 I O.OOE+00 0.OOE+00 0.OOE+00 I PARTICULATES SR-89 CURIES 3.73E-08 9.22E-09 0.OOE+00 0.OOE+00 l CO-60 CURIES 0.OOE+00 2.58E-07 0.OOE+00 0.OOE+00 l TOTAL FOR PERIOD I
CURIES j 3.73E-08 I 2.67E-07 0.OOE+00 I 0.OOE+00 I H-3 CURIES 1.62E+00 4.05E+00 0.OOE+00 0.OOE+00 G-ALPHA CURIES 1.54E-08 0.OOE+00 0.OOE+00 0.OOE+00 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
49
TABLE 2-2B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2005 Gaseous Effluents-Mixed-Mode Level Releases Unit: 2 Starting :
l-Jan-2005 Ending : 30-Jun-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 1 1QUARTER 2 1QUARTER 1 1QUARTER 2 l FISSION GASES AR-41 CURIES 5.02E+00 7.30E+00 0.OOE+00 0.OOE+00 XE-135 CURIES 0.00E+00 0.OOE+00 0.OOE+00 7.84E-06 XE-133 CURIES 0.OOE+00 0.OOE+00 l 9.92E-04 1.90E-03 TOTAL FOR PERIOD I
CURIES I 5.02E+00 I 7.30E+00 I 9.92E-04 l.91E-03 I IODINES TOTAL FOR PERIOD I
CURIES j 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 I H-3 CURIES 3.67E+00 5.29E+00 0.OOE+00 j 0.OOE+00 G-ALPHA CURIES 2.45E-14 3.77E-08 0.OOE+00 0.OOE+00 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
50
TABLE 2-2B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Mixed-Mode Level Releases Unit: 2 Starting :
l-Jul-2005 Ending : 31-Dec-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT lQUARTER 3 lQUARTER 4 lQUARTER 3 IQUARTER 4 l FISSION GASES AR-41 CURIES 6.49E+00 l 2.17E+00 0.00E+00 l 8.88E-02 l KR-88 CURIES 0.OOE+00 l 0.OOE+00 l 0.OOE+00 5.53E-04 l KR-85M CURIES 0.OOE+00 l 0.OOE+00 0.OOE+00 l 2.05E-04 l XE-135 l CURIES l 0.OOE+00 l O.OOE+00 l 0.OOE+00 l 2.01E-03 l XE-133 l CURIES l 0.OOE+00 l O.OOE+00 4.24E-03 6.87E-03 XE-131M CURIES 0.OOE+00 l O.OOE+00 0.OOE+00 4.35E-04 TOTAL FOR PERIOD I
CURIES I 6.49E+00 I 2.17E+00 I 4.24E-03 I 9.89E-02 I IODINES I-131 I
CURIES 0.OOE+00 0.OOE+00 0.I00-E+00 I 4.27E-09 I TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I O.OOE+00 I 4.27E-09 I PARTICULATES SR-89 CURIES 1.53E-07 l 8.87E-09 0.OOE+00 0.OOE+00 l SR-90 CURIES 0.OOE+00 l 6.57E-08 0.OOE+00 l 0.OOE+00 l TOTAL FOR PERIOD I
CURIES I 1.53E-07 I 7.46E-08 I 0.OOE+00 I O.OOE+00 I H-3 CURIES 4.97E+00 2.10E+00 0.OOE+00 O.OOE+00 l G-ALPHA l CURIES l 3.31E-08 l 0.OOE+00 0.OOE+00 l 0.OOE+00 l Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
51
TABLE 2-2C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Mixed-Mode Level Releases Unit: Site Starting :
1-Jan-2005 Ending : 30-Jun-2005 l
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 1 IQUARTER 2 IQUARTER 1 IQUARTER 2 l FISSION GASES AR-41 CURIES 1.97E+01 3.01E+01 Ol.OOE+00 0.OOE+00 XE-135 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 7.84E-06 XE-133 CURIES l0.OOE+00 j 3.54E-01 9.92E-04 1.90E-03 TOTAL FOR PERIOD I
CURIES I 1.97E+01 I 3.05E+01 I 9.92E-04 Il.91E-03 I IODINES I-133 CURIES 1.17E-05 O.OOE+00 0.OOE+00 0.OOE+00 I-131 CURIES 3.36E-07 0.OOE+00 l 0.OOE+00 O.OOE+00 TOTAL FOR PERIOD I
CURIES 1.20E-05 I O.OOE+00 I 0.OOE+00 I 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES 0.OOE+00 I O.OOE+00 0.OOE+00 0.OOE+00 I H-3 CURIES 6.26E+00 7.19E+00 0.OOE+00 0.OOE+00 G-ALPHA CURIES 9.82E-08 j 4.27E-08 l0.OOE+00 O.OOE+00 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
52
TABLE 2-2C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Mixed-Mode Level Releases Unit: Site Starting :
l-Jul-2005 Ending : 31-Dec-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 3 lQUARTER 4 lQUARTER 3 IQUARTER 4 l FISSION GASES AR-41 CURIES 1.52E+01 3.62E+0l 0.OOE+00 8.88E-02 KR-88 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 5.53E-04 KR-85M CURIES 0.OOE+00 O.OOE+00 0.OOE+00 2.05E-04 XE-135 CURIES 0.OOE+00 0.OOE+00 0.OOE+00 2.0lE-03 XE-133 CURIES 0.OOE+00 0.OOE+00 l 4.24E-03 6.87E-03 XE-131M CURIES 0.OOE+00 0.OOE+00 0.OOE+00 4.35E-04 TOTAL FOR PERIOD I
CURIES I 1.52E+01 I 3.62E+01 I 4.24E-03 I 9.89E-02 I IODINES I-131 I
CURIES I 0.00E+00 I 0.OOE+00 I 0.OOE+00 I 4.27E-09 I TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 4.27E-09 I PARTICULATES SR-89 CURIES 1.90E-07 1.81E-08 0.OOE+00 l 0.OOE+00 CO-60 CURIES 0.OOE+00 2.58E-07 j 0.OOE+00 0.OOE+00 SR-90 CURIES 0.OOE+00 6.57E-08 0.OOE+00 0.OOE+00 TOTAL FOR PERIOD I
CURIES I 1.90E-07 I 3.42E-07 I 0.OOE+00 I 0.OOE+00 I H-3 CURIES 6.59E+00 6.15E+00 0.OOE+00 l 0.OOE+00 G-ALPHA j CURIES 4.85E-08 0.OOE+00 0.OOE+00 0.OOE+00 Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
53
TABLE 2-3A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2005 Gaseous Effluents-Ground Level Releases Unit: 1 Starting :
1-Jan-2005 Ending : 30-Jun-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 1 IQUARTER 2 IQUARTER 1 IQUARTER 2 l FISSION GASES TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I IODINES TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I H-3 I
CURIES I 8.47E-05 I 2.88E-05 0.OOE+00 I 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
54
TABLE 2-3A*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Ground Level Releases Unit: 1 Starting :
1-Jul-2005 Ending : 31-Dec-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 3 IQUARTER 4 IQUARTER 3 IQUARTER 4 l FISSION GASES TOTAL FOR PERIOD I
CURIES j 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 I IODINES TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I O.OOE+00 I 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I H-3 I
CURIES I 4.01E-04 I 5.79E-05 0.OOE+00 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
55
TABLE 2-3B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Ground Level Releases Unit: 2 Starting :
l-Jan-2005 Ending : 30-Jun-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED j
UNIT jQUARTER 1 IQUARTER 2 IQUARTER 1 IQUARTER 2 l FISSION GASES TOTAL FOR PERIOD I
CURIES 0.OOE+00 I 0.OOE+00 0.OOE+00 j 0.OOE+00 I IODINES TOTAL FOR PERIOD I
CURIES I O.OOE+00 I 0.OOE+00 0.OOE+00 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES 0.OOE+00 0.I E-E+00 I 0.OOE+00 0.OOE+00 I H-3 I
CURIES I 2.47E-04 0.OOE+00 j 0.OOE+00 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
56
TABLE 2-3B*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2005 Gaseous Effluents-Ground Level Releases Unit: 2 Starting : 1-Jul-2005 Ending : 31-Dec-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 3 IQUARTER 4 IQUARTER 3 IQUARTER 4 l FISSION GASES I
TOTAL FOR PERIOD I
CURIES 0.OOE+00 I O.OOE+00 0.OOE+00 0.OOE+00 I IODINES TOTAL FOR PERIOD I
CURIES I 0.OOE+00 0.OOE+00 I 0.OOE+00 j 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 I H-3 I
CURIES 0.OOE+00 I 1.46E-04 I O.OOE+00 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
57
TABLE 2-3C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Ground Level Releases Unit: Site Starting :
1-Jan-2005 Ending : 30-Jun-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 1 IQUARTER 2 1QUARTER 1 IQUARTER 2 l FISSION GASES TOTAL FOR PERIOD I
CURIES 0.OOE+00 0.OOE+00 I O.OOE+00 0.OOE+00 I IODINES TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I O.OOE+00 j 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I H-3 I
CURIES I 3.32E-04 I 2.88E-05 0.OOE+00 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
58
TABLE 2-3C*
Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents-Ground Level Releases Unit: Site Starting : 1-Jul-2005 Ending : 31-Dec-2005 I
CONTINUOUS MODE I
BATCH MODE I
NUCLIDES RELEASED I
UNIT IQUARTER 3 IQUARTER 4 jQUARTER 3 jQUARTER 4 l FISSION GASES I
TOTAL FOR PERIOD I
CURIES I O.OOE+00 I O.OOE+00 I O.OOE+00 I O.OOE+00 I IODINES TOTAL FOR PERIOD I
CURIES 0.OOEE+00 I 0.OOE+00 I 0.OOE+00 I 0.OOE+00 I PARTICULATES TOTAL FOR PERIOD I
CURIES 0.OOE+00 0.OOE+00 0.IOOEE+00 I O.OOE+00 I H-3 I
CURIES I 4.01E-04 I 2.04E-04 0.OOE+00 0.OOE+00 I Zeroes in this table indicate that no radioactivity was present at detectable levels.
See Table 2-6 for typically achieved minimum detectable concentrations.
59
TABLE 2-4A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 AIR DOSES DUE TO NOBLE GASES IN GASEOUS RELEASES Unit: 1 Starting: 01-Jan-2005 Ending: 30-Jun-2005 Cumulative Doses per Quarter Type ODCM Units Quarter
% of Quarter
% of of Limit 1
ODCM 2
ODCM Radi-Limit Limit ation Gamma 5.0 mrad 4.69E-03 9.37E-02 7.28E-03 1.46E-01 Beta 10.0 mrad 1.65E-03 1.65E-02 2.58E-03 2.58E-02 Cumulative Doses per Year Type ODCM Units Year to
% of of Limit Ending ODCM Radi-Date Limit ation Gamma 10.0 mrad 1.20E-02 1.20E-01 Beta 20.0 mrad 4.23E-03 2.12E-02 60
TABLE 2-4A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 AIR DOSES DUE TO NOBLE GASES IN GASEOUS RELEASES Unit: 1 Starting: 01-Jul-2005 Ending: 31-Dec-2005 Cumulative Doses per Quarter Type ODCM Units Quarter
% of Quarter
% of of Limit 3
ODCM 4
ODCM Radi-Limit Limit ation Gamma 5.0 mrad 2.77E-03 5.55E-02 1.08E-02 2.17E-01 Beta 10.0 mrad 9.78E-04 9.78E-03 3.82E-03 3.82E-02 Cumulative Doses per Year Type ODCM Units Year to
% of of Limit Ending ODCM Radi-Date Limit ation Gamma 10.0 mrad 2.56E-02 2.56E-01 Beta 20.0 mrad 9.03E-03 4.52E-02 61
TABLE 2-4B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 AIR DOSES DUE TO NOBLE GASES IN GASEOUS RELEASES Unit: 2 Starting: 01-Jan-2005 Ending: 30-Jun-2005 Cumulative Doses per Quarter Type ODCM Units Quarter
% of Quarter
% of of Limit 1
ODCM 2
ODCM Radi-Limit Limit ation Gamma 5.0 mrad 1.60E-03 3.20E-02 2.32E-03 4.65E-02 Beta 10.0 mrad 5.64E-04 5.64E-03 8.20E-04 8.20E-03 Cumulative Doses per Year Type ODCM Units Year to
% of of Limit Ending ODCM Radi-Date Limit ation Gamma 10.0 mrad 3.92E-03 3.92E-02 Beta 20.0 mrad 1.38E-03 6.92E-03 62
TABLE 2-4B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 AIR DOSES DUE TO NOBLE GASES IN GASEOUS RELEASES Unit: 2 Starting: 01-Jul-2005 Ending: 31-Dec-2005 Cumulative Doses per Quarter Type ODCM Units Quarter
% of Quarter
% of of Limit 3
ODCM 4
ODCM Radi-Limit Limit ation Gamma 5.0 mrad 2.07E-03 4.13E-02 7.19E-04 1.44E-02 Beta 10.0 mrad 7.29E-04 7.29E-03 2.54E-04 2.54E-03 Cumulative Doses per Year Type ODCM Units Year to
% of of Limit Ending ODCM Radi-Date Limit ation Gamma 10.0 mrad 6.71E-03 6.71E-02 Beta 20.0 mrad 2.37E-03 1.18E-02 63
TABLE 2-5A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES Unit: 1 Starting: 01-Jan-2005 Ending: 30-Jun-2005 Cumulative Doses per Quarter Organ ODCM Unit Quarter
% of Quarter
% of Limit 1
ODCM 2
ODCM Limit Limit Bone 7.5 mrem 4.91E-08 6.55E-07 3.55E-11 4.73E-10 Liver 7.5 mrem 3.54E-04 4.72E-03 2.60E-04 3.46E-03 TBody 7.5 mrem 3.54E-04 4.72E-03 2.60E-04 3.46E-03 Thyroid 7.5 mrem 3.64E-04 4.86E-03 2.60E-04 3.46E-03 Kidney 7.5 mrem 3.54E-04 4.72E-03 2.60E-04 3.46E-03 Lung 7.5 mrem 3.54E-04 4.72E-03 2.60E-04 3.46E-03 GILLI 7.5 mrem 3.54E-04 4.72E-03 2.60E-04 3.46E-03 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 15.0 mrem 4.92E-08 3.28E-07 Liver 15.0 mrem 6.14E-04 4.09E-03 TBody 15.0 mrem 6.14E-04 4.09E-03 Thyroid 15.0 mrem 6.24E-04 4.16E-03 Kidney 15.0 mrem 6.14E-04 4.09E-03 Lung 15.0 mrem 6.14E-04 4.09E-03 GILLI 15.0 mrem 6.14E-04 4.09E-03 64
TABLE 2-5A Joseph M. Parley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES Unit: 1 Starting: 01-Jul-2005 Ending: 31-Dec-2005 Cumulative Doses per Quarter Organ ODCM Unit Quarter
% of Quarter
% of Limit 3
ODCM 4
ODCM Limit Limit Bone 7.5 mrem 4.88E-07 6.51E-06 1.98E-06 2.64E-05 Liver 7.5 mrem 2.22E-04 2.96E-03 5.56E-04 7.41E-03 TBody 7.5 mrem 2.22E-04 2.96E-03 5.56E-04 7.41E-03 Thyroid 7.5 mrem 2.22E-04 2.96E-03 5.56E-04 7.41E-03 Kidney 7.5 mrem 2.22E-04 2.96E-03 5.56E-04 7.41E-03 Lung 7.5 mrem 2.22E-04 2.96E-03 5.56E-04 7.41E-03 GILLI 7.5 mrem 2.22E-04 2.96E-03 5.56E-04 7.41E-03 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 15.0 mrem 2.51E-06 1.68E-05 Liver 15.0 mrem 1.39E-03 9.28E-03 TBody 15.0 mrem 1.39E-03 9.28E-03 Thyroid 15.0 mrem 1.40E-03 9.35E-03 Kidney 15.0 mrem 1.39E-03 9.28E-03 Lung 15.0 mrem 1.39E-03 9.28E-03 GILLI 15.0 mrem 1.39E-03 9.28E-03 65
TABLE 2-5B Joseph M. Parley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES Unit: 2 Starting: 01-Jan-2005 Ending: 30-Jun-2005 Cumulative Doses per Quarter Organ ODCM Unit Quarter
% of Quarter
% of Limit 1
ODCM 2
ODCM Limit Limit Bone 7.5 mrem 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Liver 7.5 mrem 5.01E-04 6.69E-03 7.22E-04 9.63E-03 TBody 7.5 mrem 5.01E-04 6.69E-03 7.22E-04 9.63E-03 Thyroid 7.5 mrem 5.01E-04 6.69E-03 7.22E-04 9.63E-03 Kidney 7.5 mrem 5.01E-04 6.69E-03 7.22E-04 9.63E-03 Lung 7.5 mrem 5.01E-04 6.69E-03 7.22E-04 9.63E-03 GILLI 7.5 mrem 5.01E-04 6.69E-03 7.22E-04 9.63E-03 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 15.0 mrem 0.OOE+00 0.00E+00 Liver 15.0 mrem 1.22E-03 8.16E-03 TBody 15.0 mrem 1.22E-03 8.16E-03 Thyroid 15.0 mrem 1.22E-03 8.16E-03 Kidney 15.0 mrem 1.22E-03 8.16E-03 Lung 15.0 mrem 1.22E-03 8.16E-03 GILLI 15.0 mrem 1.22E-03 8.16E-03 66
TABLE 2-5B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSES TO A MEMBER OF THE PUBLIC DUE TO RADIOIODINES, TRITIUM, AND PARTICULATES IN GASEOUS RELEASES Unit: 2 Starting: 01-Jul-2005 Ending: 31-Dec-2005 Cumulative Doses per Quarter Organ ODCM Unit Quarter
% of Quarter
% of Limit 3
ODCM 4
ODCM Limit Limit Bone 7.5 mrem 1.86E-06 2.47E-05 2.76E-05 3.68E-04 Liver 7.5 mrem 6.79E-04 9.05E-03 2.87E-04 3.83E-03 TBody 7.5 mrem 6.79E-04 9.05E-03 2.94E-04 3.92E-03 Thyroid 7.5 mrem 6.79E-04 9.05E-03 2.87E-04 3.83E-03 Kidney 7.5 mrem 6.79E-04 9.05E-03 2.87E-04 3.83E-03 Lung 7.5 mrem 6.79E-04 9.05E-03 2.87E-04 3.83E-03 GILLI 7.5 mrem 6.79E-04 9.05E-03 2.87E-04 3.83E-03 Cumulative Doses per Year Organ ODCM Units Year to
% of Limit Ending ODCM Date Limit Bone 15.0 mrem 2.95E-05 1.96E-04 Liver 15.0 mrem 2.19E-03 1.46E-02 TBody 15.0 mrem 2.20E-03 1.46E-02 Thyroid 15.0 mrem 2.19E-03 1.46E-02 Kidney 15.0 mrem 2.19E-03 1.46E-02 Lung 15.0 mrem 2.19E-03 1.46E-02 GILLI 15.0 mrem 2.19E-03 1.46E-02 67
TABLE 2-6 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 MINIMUM DETECTABLE CONCENTRATIONS -
GASEOUS EFFLUENT ANALYSES The values in this table represent a priori Minimum Detectable Concentrations (MDC) that are typically achieved in laboratory analyses of gaseous radwaste samples.
Nuclide MDC(uCi/ML)
MN-54 3.21E-15 CO-58 1.53E-14 FE-59 7.96E-15 CO-60 1.95E-14 ZN-65 2.34E-14 MO-99 1.81E-13 CS-134 1.41E-14 CS-137 7.83E-15 CE-141 6.96E-15 CE-144 3.47E-14 KR-87 8.18E-07 KR-88 3.94E-08 XE-133 4.30E-08 XE-133M 4.82E-08 XE-135 1.78E-08 XE-138 l.99E-07 I-131 9.67E-15 I-133 1.80E-13 68
TABLE 2-7A Joseph M. Parley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Batch Release Summary Unit: 1 Starting : 1-Jan-2005 Ending : 30-Jun-2005 GASEOUS RELEASES NUMBER OF BATCH RELEASES 0
TOTAL TIME PERIOD FOR BATCH RELEASES 0.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE :
0.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 0.00 MINUTES MINIMUM TIME FOR A BATCH RELEASE 0.00 MINUTES 69
TABLE 2-7A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Batch Release Summary Unit: 1 Starting :
1-Jul-2005 Ending : 31-Dec-2005 GASEOUS RELEASES NUMBER OF BATCH RELEASES 0
TOTAL TIME PERIOD FOR BATCH RELEASES 0.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE :
0.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 0.00 MINUTES MINIMUM TIME FOR A BATCH RELEASE 0.00 MINUTES 70
TABLE 2-7B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Batch Release Summary Unit: 2 Starting :
1-Jan-2005 Ending : 30-Jun-2005 GASEOUS RELEASES NUMBER OF BATCH RELEASES 13 TOTAL TIME PERIOD FOR BATCH RELEASES 4376.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE :
525.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 336.62 MINUTES MINIMUM TIME FOR A BATCH RELEASE 100.00 MINUTES 71
TABLE 2-7B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Batch Release Summary Unit: 2 Starting :
l-Jul-2005 Ending : 31-Dec-2005 GASEOUS RELEASES NUMBER OF BATCH RELEASES 32 TOTAL TIME PERIOD FOR BATCH RELEASES 10313.00 MINUTES MAXIMUM TIME PERIOD FOR A BATCH RELEASE :
485.00 MINUTES AVERAGE TIME PERIOD FOR BATCH RELEASES 322.28 MINUTES MINIMUM TIME FOR A BATCH RELEASE 135.00 MINUTES 72
TABLE 2-8A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents - Abnormal Release Summary Unit: 1 Starting : l-Jan-2005 Ending : 30-Jun-2005 GASEOUS RELEASES NUMBER OF RELEASES 0
TOTAL TIME FOR ALL RELEASES 0.00 MINUTES MAXIMUM TIME FOR A RELEASE 0.00 MINUTES AVERAGE TIME FOR A RELEASE 0.00 MINUTES MINIMUM TIME FOR A RELEASE 0.00 MINUTES TOTAL ACTIVITY FOR ALL RELEASES :
0.OOE+00 CURIES 73
TABLE 2-8A Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents - Abnormal Release Summary Unit: 1 Starting :
I-Jul-2005 Ending : 31-Dec-2005 GASEOUS RELEASES NUMBER OF RELEASES TOTAL TIME FOR ALL MAXIMUM TIME FOR A AVERAGE TIME FOR A MINIMUM TIME FOR A TOTAL ACTIVITY FOR RELEASES RELEASE RELEASE RELEASE ALL RELEASES 0
0.00 0.00 0.00
- 0. 00
- 0. OOE+00 MINUTES MINUTES MINUTES MINUTES CURIES 74
TABLE 2-8B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents - Abnormal Release Summary Unit: 2 Starting :
l-Jan-2005 Ending : 30-Jun-2005 GASEOUS RELEASES NUMBER OF RELEASES TOTAL TIME FOR ALL MAXIMUM TIME FOR A AVERAGE TIME FOR A MINIMUM TIME FOR A TOTAL ACTIVITY FOR RELEASES RELEASE RELEASE RELEASE ALL RELEASES :
0 0.00 0.00 0.00
- 0. 00
- 0. OOE+00 MINUTES MINUTES MINUTES MINUTES CURIES 75
TABLE 2-8B Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 Gaseous Effluents -
Abnormal Release Summary Unit: 2 Starting :
l-Jul-2005 Ending : 31-Dec-2005 GASEOUS RELEASES NUMBER OF RELEASES TOTAL TIME FOR ALL MAXIMUM TIME FOR A AVERAGE TIME FOR A MINIMUM TIME FOR A TOTAL ACTIVITY FOR RELEASES RELEASE RELEASE RELEASE ALL RELEASES 0
0.00 0.00 0.00
- 0. 00
- 0. OOE+00 MINUTES MINUTES MINUTES MINUTES CURIES 76
3.0 SOLID WASTE 3.1 Regulatory Requirements 3.1.1 Solid Radioactive Waste System PCP B.3.1 states in part that the radwaste solidification system shall be operable and used for the solidification and packaging of radioactive wastes to ensure meeting the requirements of 10CFR Part 20 and 10CFR Part 71 prior to shipment of radioactive wastes from the site.
3.1.2 Reporting Requirements PCP B.5.1.1 states in part that the Annual Radioactive Effluent Release Report, submitted in accordance with Technical Specification 5.6.3, shall include a summary of the quantities of solid radwaste released from the units as outlined in Regulatory Guide 1.21, with data summarized on a six-month basis following the format of Appendix B thereof.
3.2 Solid Waste Data Regulatory Guide 1.21 Table 3 is found in this report as Table 3-1.
The error involved in determining the contents of solid radwaste shipments is estimated to be less than + or -
15t.
77
TABLE 3-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Starting: 01-Jan-2005 Ending: 30-Jun-2005 A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (not irradiated fuel)
- 1. Type of Waste.
UNITS 6-Months
- a. Spent resins, Filter sludges, evaporator bottoms, etc.
3 m
2.475E+00 Ci*
7.580E+01
- b. Dry compressible waste, contaminated equipment, etc.
3 m
5.802E+01 Ci*
4.358E-01
- c. Irradiated components, control rods, etc.
3 m
None Ci*
None
- d. Other (describe) 3 m
None Ci*
None
- 2. Estimate of major nuclide composition (by type of waste).
24.5%
19.7%
15.8%
5.1%
2.9%
1.9%
16.1%
13.7%
13.4%
11.8%
10.1%
5.8%
4.1%
- 3. 9%
- Measured and/or with 10CFR61.55.
estimated by correlations in accordance 78
TABLE 3-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Starting: 01-Jan-2005 Ending: 30-Jun-2005 (continued)
- 3. Solid Waste Disposition Number of Shipments Mode of Transportation 26 Highway Destination Envirocare of Utah Barnwell, SC 4
Highway
- 4. Type of Containers (Shipped offsite for burial/processing)
Container Description Type of Container
- b. 20' Sealand Metal Box High Integrity Container High Integrity Container High Integrity Container General Design Package General Design Package Number of Containers 1
I 5
6 Container 3 Volume (m )
3.850E+00 3.410E+00 2.900E-01 2.945E+01 20 2.590E+00
- 5. Solidification Agent
- a. None
- b. None B. IRRADIATED FUEL SHIPMENTS (Disposition)
Number of Shipments Mode of Transportation Destination None N/A N/A 79
TABLE 3-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Starting: 01-Jul-2005 Ending: 31-Dec-2005 A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (not irradiated fuel)
- 1. Type of Waste.
UNITS 6-Months
- a. Spent resins, Filter sludges, evaporator bottoms, etc.
- b. Dry compressible waste, contaminated equipment, etc.
- c. Irradiated components, control rods, etc.
- d. Other (describe) 3 m
Ci*
3 m
Ci*
3 m
Ci*
3 M
Ci
- 6.170E-01 2.710E+00 4.644E+01 4.112E+00 None None None None
- 2. Estimate of major nuclide composition (by type of waste).
18.2%
12.5%
- 10. 0%
7.2%
2.8%
17.0%
12.9%
12.2%
11.4%
10.6%
- 10. 1%
8.3%
4.2%
2.8%
- Measured and/or with IOCFR61.55.
estimated by correlations in accordance 80
TABLE 3-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Starting: 01-Jul-2005 Ending: 31-Dec-2005 (continued)
- 3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination 21 1
Highway Highway Envirocare of Utah Barnwell, SC
- 4. Type of Containers Container Description
- a. RADLOC 500
- b. 20' Sealand 55 Gallon Drum Soft Package (Shipped offsite Type of Container General Design Package General Design Package General Design Package General Design Package for burial/processing)
Number Container 3 of Volume (m )
Containers 2
3.850E+00 17 2.945E+01 3
1 2.100E-01
- 3. 211E+01
- 5. Solidification Agent
- a. None
- b. None B. IRRADIATED FUEL SHIPMENTS (Disposition)
Number of Shipments Mode of Transportation Destination None N/A N/A 81
4.0 DOSES TO MEMBERS OF THE PUBLIC INSIDE THE SITE BOUNDARY 4.1 Regulatory Requirements Current FNP effluent controls as established by ODCM 6.1 do not require assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY (ODCM Figure 10-1).
4.2 Demonstration of Compliance However, this assessment has been performed for 2005 using the methods described in ODCM 6.2 and is included in this section as Table 4-1.
82
TABLE 4-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jan-2005 Ending: 30-Jun-2005 Page:
Location Name VISITOR LOCATION 1 (VIS.CENTER)
Distance (kilometers) 3.06E-01 Sector WSW Occupancy Factor 1.37E-03 (1.20E+01 hr/yr)
Age Group CHILD Ground Level Releases:
Noble Gas X/Q (sec/m3) 1.04E-04 Particulate X/Q (sec/m3) 1.04E-04 Particulate D/Q (m-2) 4.80E-07 Mixed Mode Releases:
Noble Gas X/Q (sec/m3) 8.80E-06 Particulate X/Q (sec/m3) 8.80E-06 Particulate D/Q (m-2) 6.20E-08 Elevated Releases:
Noble Gas X/Q (sec/m3)
N/A Particulate X/Q (sec/m3)
N/A Particulate D/Q (m-2)
N/A Units Quarter 1 Quarter 2 Quarters Year to 1 and 2 Ending Date Bone mrem 7.77E-05 9.35E-05 1.71E-04 1.71E-04 Liver mrem 8.06E-05 9.66E-05 1.77E-04 1.77E-04 TBody mrem 8.06E-05 9.66E-05 1.77E-04 1.77E-04 Thyroid mrem 8.06E-05 9.66E-05 1.77E-04 1.77E-04 Kidney mrem 8.06E-05 9.66E-05 1.77E-04 1.77E-04 Lung mrem 8.06E-05 9.66E-05 1.77E-04 1.77E-04 GI-LLI mrem 8.06E-05 9.66E-05 1.77E-04 1.77E-04 83
TABLE 4-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jan-20(
Location Name Distance (kilometers)
Sector Occupancy Factor Age Group Ending: 30-Jun-2005 Page:
2 VISITOR LOCATION 2 (SW POND) 9.66E-01 SSW 7.53E-03 (6.60E+01 hr/yr)
CHILD Ground Level Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Mixed Mode Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Elevated Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2) 4.74E-05 4.74E-05 1.31E-07 9.75E-07 9.75E-07 2.78E-08 N/A N/A N/A Units Quarter 1 Quarter 2 Quarters 1 and 2 Year to Ending Date Bone Liver TBody Thyroid Kidney Lung GI-LLI mrem 4.73E-05 mrem 4.91E-05 mrem 4.91E-05 mrem 4.91E-05 mrem 4.91E-05 mrem 4.91E-05 mrem 4.91E-05 5.69E-05 5.88E-05 5.88E-05 5.88E-05 5.88E-05 5.88E-05 5.88E-05 1.04E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04
- 1. 04E-04
- 1. 08E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04 84
TABLE 4-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jan-2005 Ending: 30-Jun-2005 Page:
3 Location Name Distance (kilometers)
Sector Occupancy Factor Age Group VISITOR LOCATION 3 (RW DISCH.)
1.64E+00 SE 1.14E-02 (9.99E+01 hr/yr)
CHILD Ground Level Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Mixed Mode Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Elevated Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2) 1.63E-05 1.63E-05 4.55E-08 7.05E-07 7.05E-07 1.39E-08 N/A N/A N/A Units Quarter 1 Quarter 2 Quarters 1 and 2 Year to Ending Date Bone Liver TBody Thyroid Kidney Lung GI-LLI mrem 5.18E-05 mrem 5.37E-05 mrem 5.37E-05 mrem 5.37E-05 mrem 5.37E-05 mrem 5.37E-05 mrem 5.37E-05 6.23E-05 6.44E-05 6.44E-05 6.44E-05 6.44E-05 6.44E-05 6.44E-05
- 1. 14E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 1.14E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 85
TABLE 4-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2005 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jul-2005 Ending: 31-Dec-2005 Page:
1 Location Name Distance (kilometers)
Sector Occupancy Factor Age Group VISITOR LOCATION 1 (VIS.CENTER) 3.06E-01 WSW 1.37E-03 (1.20E+01 hr/yr)
CHILD Ground Level Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Mixed Mode Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Elevated Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2) 1.04E-04 1.04E-04 4.80E-07 8.80E-06 8.80E-06 6.20E-08 N/A N/A N/A Units Quarter 3 Quarter 4 Quarters 3 and 4 Year to Ending Date Bone Liver TBody Thyroid Kidney Lung GI-LLI mrem 5.11E-05 mrem 5.39E-05 mrem 5.39E-05 mrem 5.39E-05 mrem 5.39E-05 mrem 5.39E-05 mrem 5.39E-05 1.20E-04 1.23E-04 1.23E-04 1.23E-04 1.23E-04 1.23E-04 1.23E-04 1.71E-04 1.77E-04 1.77E-04 1.77E-04 1.77E-04 1.77E-04 1.77E-04 3.43E-04 3.54E-04 3.54E-04 3.54E-04 3.54E-04
- 3. 54E-04
- 3. 54E-04 86
TABLE 4-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jul-2005 Ending: 31-Dec-2005 Page:
2 Location Name Distance (kilometers)
Sector Occupancy Factor Age Group VISITOR LOCATION 2 (SW POND) 9.66E-01 SSW 7.53E-03 (6.60E+01 hr/yr)
CHILD Ground Level Releases:
Noble Gas X/Q (sec/m3) 4.74E-05 Particulate X/Q (sec/m3) 4.74E-05 Particulate D/Q (m-2) 1.31E-07 Mixed Mode Releases:
Noble Gas X/Q (sec/m3) 9.75E-07 Particulate X/Q (sec/m3) 9.75E-07 Particulate D/Q (m-2) 2.78E-08 Elevated Releases:
Noble Gas X/Q (sec/m3)
N/A Particulate X/Q (sec/m3)
N/A Particulate D/Q (m-2)
N/A
____-------Units Quarter__ 3_
Quarter__
Units Quarter 3 Quarter 4 Quarters 3 and 4 Year to Ending Date Bone Liver TBody Thyroid Kidney Lung GI-LLI mrem 3.11E-05 mrem 3.28E-05 mrem 3.28E-05 mrem 3.28E-05 mrem 3.28E-05 mrem 3.28E-05 mrem 3.28E-05 7.33E-05 7.48E-05 7.48E-05 7.48E-05 7.48E-05 7.48E-05 7.48E-05 1.04E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04 1.08E-04 2.09E-04 2.16E-04 2.16E-04 2.16E-04 2.16E-04 2.16E-04 2.16E-04 87
TABLE 4-1 Joseph M. Farley Nuclear Plant ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT -
2005 DOSE TO A MEMBER OF THE PUBLIC DUE TO ACTIVITIES INSIDE THE SITE BOUNDARY Unit: Site Starting: 01-Jul-20C Location Name Distance (kilometers)
Sector Occupancy Factor Age Group Ending: 31-Dec-2005 Page:
3 VISITOR LOCATION 3 (RW DISCH.)
1.64E+00 SE 1.14E-02 (9.99E+01 hr/yr)
CHILD Ground Level Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Mixed Mode Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2)
Elevated Releases:
Noble Gas X/Q (sec/m3)
Particulate X/Q (sec/m3)
Particulate D/Q (m-2) 1.63E-05 1.63E-05 4.55E-08 7.05E-07 7.05E-07 1.39E-08 N/A N/A N/A Units Quarter 3 Quarter 4 Quarters 3 and 4 Year to Ending Date Bone Liver TBody Thyroid Kidney Lung GI-LLI mrem 3.41E-05 mrem 3.59E-05 mrem 3.59E-05 mrem 3.59E-05 mrem 3.59E-05 mrem 3.59E-05 mrem 3.59E-05
- 8. 03E-05 8.19E-05 8.19E-05 8.19E-05 8.19E-05 8.19E-05 8.19E-05 1.14E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 1.18E-04 2.28E-04 2.36E-04 2.36E-04 2.36E-04 2.36E-04 2.36E-04 2.36E-04 88
5.0 TOTAL DOSE FROM URANIUM FUEL CYCLE (40CFR190) 5.1 Regulatory Requirements Technical Specification 5.5.4.j states that the dose or dose commitment to any MEMBER OF THE PUBLIC over a calendar year, due to releases of radioactivity and to radiation from uranium fuel cycle sources, shall be limited to less than or equal to 25 mrem to the total body or to any organ, except the thyroid, which shall be limited to less than or equal to 75 mrem (as stated in ODCM 5.1).
With the calculated doses from the release of radioactive materials in liquid or gaseous effluents exceeding twice the limits of ODCM 2.1.3, 3.1.3, or 3.1.4, calculations shall be made according to ODCM 5.2 methods to determine whether the above (ODCM 5.1) limits have been exceeded (as stated in ODCM 5.1.2).
5.2 Demonstration of Compliance Since none of the ODCM 2.1.3, 3.1.3, or 3.1.4 limits were exceeded during 2005, no calculations were required.
6.0 METEOROLOGICAL DATA Meteorological data are retained onsite; these data are available to the NRC upon request. The meteorological data include annual as well as quarterly summaries of hourly measurements of wind speed, wind direction and atmospheric stability in the form of joint frequency distribution tables.
7.0 PROGRAM DEVIATIONS 7.1 Inoperable Liquid or Gaseous Effluent Monitoring Instrumentation 7.1.1 Regulatory Requirements ODCM 7.2.2.6 states in part that the Annual Radioactive Effluent Release Report (the report) shall include deviations from the liquid and gaseous effluent monitoring instrumentation operability requirements included in Sections 2.1.1 and 3.1.1 of the ODCM. The report must also include an explanation as to why the inoperability was not corrected in a timely manner.
7.1.2 Description of Deviations There was one deviation from gaseous effluent monitoring instrumentation operability requirements during 2005. The Unit 2 Plant Vent Stack flow recorder was taken out of service for approximately one week during February, 2005 while it was being replaced with a paperless recorder. Default flow values were used while the recorder was out of service, in accordance with plant procedures. Details of this deviation are documented in condition report 2005102103.
89
7.2 Effluent Sample Analysis Exceeding Minimum Detectable Concentration (MDC) 7.2.1 Regulatory Requirements ODCM 7.2.2.6 states in part that the report shall include deviations from the MDC requirements included in ODCM Tables 2-3 and 3-3.
7.2.2 Description of Deviations There were no deviations during 2005.
7.3 Incorrect Compositing of Liquid or Gaseous Effluent Samples 7.3.1 Regulatory Requirements ODCM 7.2.2.6 states in part that the report shall include deviations from composite sampling requirements included in ODCM Tables 2-3 and 3-3.
7.3.2 Description of Deviations There was one deviation from liquid effluent sampling requirements during 2005. Unit 2 had a deviation on January 13, 2005, when the autosampler for Turbine Building Sump 2B failed to collect a sample for the day. Details of this event are documented in condition report 2005100552.
8.0 CHANGES TO THE PLANT FARLEY ODCM 8.1 Regulatory Requirements Pursuant to Technical Specification 5.5.1.c and ODCM 7.2.2.5, licensee initiated changes to the ODCM shall be submitted to the Nuclear Regulatory Commission as a part of or concurrent with the Annual Radioactive Effluent Release Report for the period in which any changes were made. Included are changes to the radiological environmental monitoring program sampling locations or dose calculation locations or pathways, including any changes made pursuant to ODCM 4.1.2.2.2 (land use census).
8.2 Description of Changes There was one revision to the ODCM during 2005. Gaseous effluent sampling requirements were changed to bring them into agreement with NUREG-1301. Batch release of containment atmosphere was also included as an additional option to the continuous release of containment atmosphere. This revision accompanies this report.
90
9.0 MAJOR CHANGES TO LIQUID, GASEOUS, OR SOLID RADWASTE TREATMENT SYSTEMS 9.1 Regulatory Requirements ODCM 7.2.2.7 states in part that, as required by ODCM 2.1.5 and 3.1.6, licensee initiated MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS (liquid and gaseous) shall be reported to the Nuclear Regulatory Commission in the Annual Radioactive Effluents Release Report covering the period in which the change was reviewed and accepted for implementation.
Process Control Program (PCP) B.5.1.2 states that licensee initiated major changes to the solid radioactive waste treatment system shall be reported to the Nuclear Regulatory Commission in the Annual Radioactive Effluent Release Report for the period in which the change was implemented. The discussion of each change shall include the information specified in PCP B.4.1.
9.2 Description of Major Changes There were no major changes during 2005.
91