Frequency 1.4 1.4 Frequency EXAMPLE 1.4-1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY Perform CHANNEL CHECK.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Example 1.4-1 contains the type of SR most often encountered in the Technical Specifications (TS).

The Frequency specifies an interval (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />) during which the associated Surveillance must be performed at least one time.

Performance of the Surveillance initiates the subsequent interval.

Although the Frequency is stated as 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, an extension of the time interval to 1.25 times the stated Frequency is allowed by SR 3.0.2 for operational flexibility.

The measurement of this interval continues at all times, even when the SR is not required to be met per SR 3.0.1 (such as when the equipment is inoperable, a variable is outside specified limits, or the unit is outside the Applicability of the LCO).

If the interval specified by SR 3.0.2 is exceeded while the unit is in a MODE or other specified condition in the Applicability of the LCO, and the performance of the Surveillance is not otherwise modified (refer to Example 1.4-3), then SR 3.0.3 becomes applicable.

If the interval as specified by SR 3.0.2 is exceeded while the unit is not in a MODE or other specified condition in the Applicability of the LCO for which performance of the SR is required, the Surveillance must be performed within the Frequency requirements of SR 3.0.2 prior to entry into the MODE or other specified condition except as provided in SR 3.0.4.

CALVERT CLIFFS - UNIT 1 1.4-2 Amendment No. 276 CALVERT CLIFFS - UNIT 2 Amendment No. 253

LCO Applicability 3.0 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY LCO 3.0.4 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:

a. When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time, or
b. After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate; exceptions to this Specification are stated in the individual Specifications, or
c. When a note is inserted in the individual value, parameter, or other Specification, that allows application of this part.

This Specification shall not prevent changes in MODEs or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

LCO 3.0.5 Equipment removed from service or declared inoperable.to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment.

This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.

LCO 3.0.6 CALVERT CLIFFS -

CALVERT CLIFFS -

When a supported system LCO is not met solely due to a support system LCO not being met, the Conditions and Required Actions associated with this supported system are UNIT 1 UNIT 2 3.0-2 Amendment No. 276 Amendment No. 253

LCO Applicability 3.0 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY not required to be entered. Only the support system LCO ACTIONS are required to be entered.

This is an exception to LCO 3.0.2 for the supported system.

In this event, additional evaluations and limitations may be required in accordance with Specification 5.5.15, "Safety Function Determination Program (SFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.

When a support system's Required Action directs a supported system to be declared inoperable or directs entry into Conditions and Required Actions for a supported system, the applicable Conditions and Required Actions shall be entered in accordance with LCO 3.0.2.

LCO 3.0.7 Special test exception (STE)

LCOs in each applicable LCO section allow specified Technical Specification (TS) requirements to be changed to permit performance of special tests and operations.

Unless otherwise specified, all other TS requirements remain unchanged.

Compliance with STE LCOs is optional.

When an STE LCO is desired to be met but is not met, the ACTIONS of the STE LCO shall be met.

When an STE LCO is not desired to be met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with the other applicable Specifications.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.0-3 Amendment No. 276 Amendment No. 253

SR Applicability 3.0 3.0 SURVEILLANCE REQUIREMENT (SR) APPLICABILITY If the Surveillance is not performed within the delay period, the LCO must immediately be declared not met, and the applicable Condition(s) must be entered.

When the Surveillance is performed within the delay period and the Surveillance is not met, the LCO must immediately be declared not met, and the applicable Condition(s) must be entered.

SR 3.0.4 Entry into a MODE or other specified condition in the Applicability of an LCO shall only be made when the LCO's Surveillances have been met within their specified Frequency, except as provided by SR 3.0.3.

When an LCO is not met due to Surveillances not having been met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with LCO 3.0.4.

I This provision shall not prevent entry into MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of the shutdown of the unit.

I I

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.0-5 Amendment No. 276 Amendment No. 253

RPS Instrumentation-Operating 3.3.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. One or more Functions B.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with two RPS bistable bistable trip unit in trip units or bypass and place the associated other affected measurement channels bistable trip unit in inoperable except for trip.

Condition C (excore channel not AND calibrated with incore detectors).

B.2 Restore one affected 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bistable trip unit and associated measurement channel to OPERABLE status.

C. One or more Functions C.1 Perform SR 3.3.1.3.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with one or more power range excore OR channels not calibrated with the C.2 Restrict THERMAL 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> incore detectors.

POWER to < 90% RTP.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.1-2 Amendment No. 276 Amendment No. 253

RPS Instrumentation-Operating 3.3.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E. One or more Functions E.1 Disable bypass 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with two automatic channels.

bypass removal feature channels OR inoperable.

E.2.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> bistable trip unit in bypass and place the other in trip for each affected trip Function.

AND E.2.2 Restore one automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bypass removal feature and the affected bistable trip unit to OPERABLE status for each affected trip Function.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.1-4 Amendment No. 276 Amendment No. 253

RPS Instrumentation-Shutdown 3.3.2 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME A.

(Continued)

A.2.2 Place affected 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bistable trip unit in trip.

B. Two Rate of Change of B.1 Place one bistable 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Power-High bistable trip unit in bypass trip units or and place the other associated bistable trip unit in measurement channels trip.

inoperable.

AND B.2 Restore one bistable 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> trip unit to OPERABLE status.

C. One automatic bypass C.1 Disable bypass 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> removal feature channel.

inoperable.

OR C.2.1 Place affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> bistable trip unit in bypass or trip.

AND I

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.2-2 Amendment No. 276 Amendment No. 253

RPS Instrumentation-Shutdown 3.3.2 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. (Continued)

C.2.2.1 Restore automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bypass removal feature and affected bistable trip unit to OPERABLE status.

OR 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> C.2.2.2 Place affected bistable trip unit in trip.

D. Two automatic bypass D.1 Disable bypass 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> removal features channels.

inoperable.

OR D.2.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> bistable trip unit in bypass and place the other in trip.

AND D.2.2 Restore one automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> bypass removal feature and the affected bistable trip unit to OPERABLE status.

E.

Required Action and E.1 Open all reactor trip 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion circuit breakers.

Time not met.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.2-3 Amendment No.

276 Amendment No.

253

RPS Instrumentation-Shutdown 3.3.2 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.2.1 Perform a CHANNEL CHECK of each Wide Range 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Logarithmic Neutron Flux Monitor.

SR 3.3.2.2 Perform a CHANNEL FUNCTIONAL TEST on the Once within Rate of Change of Power trip instrument 7 days prior to channel.

The allowable value shall be each reactor

< 2.6 dpm.

startup SR 3.3.2.3 Perform a CHANNEL FUNCTIONAL TEST on each 24 months automatic bypass removal feature.

SR 3.3.2.4


NOTE-------------------

Neutron detectors are excluded from CHANNEL CALIBRATION.

Perform a CHANNEL CALIBRATION, including 24 months automatic bypass removal features.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.2-4 Amendment No. 276 Amendment No. 253

ESFAS Instrumentation 3.3.4 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. One or more Functions B.1 Place one sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with two ESFAS sensor module in bypass and modules or associated place the other measurement channels sensor module in inoperable.

trip.

AND B.2 Restore one sensor 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> module and associated measurement channel to OPERABLE status.

C. One or more Functions C.1 Disable affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with the automatic sensor block module.

block removal feature of one-sensor block OR module inoperable.

C.2 Place affected sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> block module in bypass.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.4-2 Amendment No. 276 Amendment No. 253

ESFAS Instrumentation 3.3.4 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME D. One or more Functions D.1 Disable affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with the automatic sensor block modules.

block removal feature of two sensor block OR modules inoperable.

D.2.1 Place one affected 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> sensor block module in bypass and disable the other for each affected ESFAS Function.

AND D.2.2 Restore one automatic 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> block removal feature and the associated sensor block module to OPERABLE status for each affected ESFAS Function.

E. Required Action and E.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND E.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> I

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.4-3 Amendment No.276 Amendment No.253

DG-LOVS

-3.3.6 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. One or more Functions B.1 Enter applicable 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with two sensor Conditions and modules or associated Required Actions for measurement channels the associated DG per DG inoperable.

made inoperable by DG-LOVS instrumentation.

OR B.2.1 Place one sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> module in bypass and the other sensor module in trip.

AND B.2.2 Restore one sensor 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> module and associated measurement channel to OPERABLE status.

C. One or more Functions C.1 Restore at least two 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> with more than two sensor modules and sensor modules or associated associated measurement channels measurement channels to OPERABLE status.

inoperable.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.6-2 Amendment No. 276 Amendment No. 253

CVCS Isolation Signal 3.3.9 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. Two CVCS isolation C.1 Place one sensor 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> sensor modules or module in bypass and associated place the other measurement channels sensor module in inoperable.

trip.

AND C.2 Restore one sensor 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> module and associated measurement channel to OPERABLE status.

D. Required Action and D.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND D.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.9.1 Perform a CHANNEL CHECK of each sensor 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> channel.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.9-2 Amendment No. 276 Amendment No. 253

PAM Instrumentation 3.3.10 3.3 INSTRUMENTATION 3.3.10 Post-Accident Monitoring (PAM) Instrumentation LCO 3.3.10 The PAM indication channels for each Function in Table 3.3.10-1 shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS


NOTE---------


l Separate Condition entry is allowed for each Function.

I CONDITION REQUIRED ACTION COMPLETION TIME A. One or more Functions A.1 Restore required 30 days with one required indication channel to indication channel OPERABLE status.

inoperable.

B. Required Action and B.1 Initiate action in Immediately associated Completion accordance with Time of Condition A Specification 5.6.7.

not met.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3.10-1 Amendment No.276 Amendment No. 253

Remote Shutdown Instrumentation 3.3.11 3.3 INSTRUMENTATION 3.3.11 Remote Shutdown Instrumentation LCO 3.3. 11 The Remote Shutdown Instrumentation Functions in Table 3.3.11-1 shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS


NOTE-------------------------------------

Separate Condition entry is allowed for each function.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more required A.1 Restore required 30 days Functions inoperable.

Functions to OPERABLE status.

B. Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND B.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.3. 11-1 Amendment No. 276 Amendment No. 253

Pressurizer PORVs 3.4.11 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.11 Pressurizer Power-Operated Relief Valves (PORVs)

LCO 3.4.11 Two PORVs and associated block valves shall be OPERABLE.

APPLICABILITY:

MODES 1 and 2, MODE 3 with all RCS cold leg temperatures > 3650F (Unit 1),

> 301'F (Unit 2).

ACTIONS


NOTE----------_-__-_-_-__-

Separate Condition entry is allowed for each PORV.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or two PORVs A.1 Close and maintain 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable and power to associated capable of being block valve.

manually cycled.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.11-1 Amendment No. 276 Amendment No. 253

LTOP System 3.4.12 Figure 3.4.12-1 when the SDC System is not in operation and PORV lift setting < 429 psia (Unit 1), < 443 psia (Unit 2), when the SDC is in operation; and an RCS vent of 2 1.3 square inches established; or

3. An RCS vent of > 2.6 square inches established.

APPLICABILITY:

MODE 3 with any RCS cold leg temperature < 3650F (Unit 1),

< 301FF (Unit 2),

MODES 4, 5, and 6.


NOTE ----------------------------

This Specification is not applicable when the RCS is vented to 2 8 square inches.

ACTIONS


NOTE-------------------------------------

LCO 3.0.4.b is not applicable to PORVs when entering MODE 3.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more HPSI A.1 Initiate action to Immediately pumps capable of verify a maximum of automatically one HPSI pump only injecting into the capable of manually RCS.

injecting into the RCS and no HPSI pumps OR capable of automatically Two or more HPSI injecting into the pumps capable of RCS.

manually injecting into the RCS.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.12-2 Amendment No. 276 Amendment No. 253

LTOP System 3.4.12 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. HPSI flow > 210 gpm B.1 Initiate action to Immediately and suction aligned reduce flow to to refueling water

< 210 gpm.

tank.

AND RCS vent < 2.6 square inches established.

C. One or more HPSI loop C.1 Initiate action to Immediately MOVs capable of verify HPSI loop MOVs automatically are only capable of aligning HPSI pump manually aligning flow to the RCS.

HPSI pump flow to the RCS.

D. One of two required D.1 Restore required PORV 5 days PORVs inoperable in to OPERABLE status.

MODE 3 with any RCS cold leg temperature

< 3650F (Unit 1),

< 301OF (Unit 2), or MODE 4.

AND RCS vent < 1.3 square inches established.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.12-3 Amendment No276 Amendment No?53

LTOP System 3.4.12 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E. One of two required E.1 Restore required PORV 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> PORVs inoperable in to OPERABLE status.

MODE 5 or 6.

AND RCS vent < 1.3 square inches established.

F. Required Action and F.1 Depressurize RCS and 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> associated Completion establish RCS vent Time of Condition D

> 1.3 square inches.

or E not met.

G. All required PORVs G.1 Depressurize RCS and 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> inoperable.

establish RCS vent of

> 2.6 square inches.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.12-4 Amendment No. 276 Amendment No. 253

RCS Leakage Detection Instrumentation 3.4.14 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.14 RCS Leakage Detection Instrumentation LCO 3.4.14 The following RCS leakage detection instrumentation shall be OPERABLE:

a. One containment sump level alarm; and
b. One containment atmosphere radioactivity monitor (gaseous or particulate).

APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTIONS I

CONDITION REQUIRED ACTION COMPLETION TIME A. Required containment A.1 Perform SR 3.4.13.1.

Once per sump level alarm 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> inoperable.

AND A.2 Restore containment 30 days sump level alarm to OPERABLE status.

r CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.14-1 Amendment No. 276 Amendment No. 253

RCS Specific Activity 3.4.15 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.15 RCS Specific Activity LCO 3.4.15 The specific activity of the reactor coolant shall be within limits.

APPLICABILITY:

MODES 1 and 2, MODE 3 with RCS average temperature (Tavg) 2 5000F.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. DOSE EQUIVALENT I-131


NOTE ------------

> 1.0 pCi/gm.

LCO 3.0.4.c is applicable.

A.1 Verify DOSE Once per EQUIVALENT I-131 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> within the acceptable region of Figure 3.4.15-1.

AND A.2 Restore DOSE 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> EQUIVALENT I-131 to within limit.

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.4.15-1 Amendment No.276 Amendment No. 253

ECCS - Shutdown 3.5.3 3.5 EMERGENCY CORE COOLING SYSTEM (ECCS) 3.5.3 ECCS - Shutdown LCO 3.5.3 One high pressure safety injection (HPSI) train shall be OPERABLE.


NOTE ----------------------------

When Reactor Coolant System cold leg temperatures are < 385 0F (Unit 1), < 3251F (Unit 2) during heatup or cooldown and when

< 365 0F (Unit 1), < 301OF (Unit 2), during other conditions, the HPSI train is not required to be capable of automatically starting on an actuation signal.

APPLICABILITY:

ACTIONS MODE 3 with pressurizer pressure < 1750 psia, MODE 4.


NOTE-------------------------------------

LCO 3.0.4.b is not applicable to ECCS High Pressure Safety Injection subsystem when entering MODE 4.

CONDITION REQUIRED ACTION COMPLETION TIME A.

Required HPSI train A.1 Restore required HPSI 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable.

train to OPERABLE status.

B. Required Action and B.1 Be in MODE 5.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> associated Completion Time not met.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.5.3-1 Amendment No. 276 Amendment No.253

AFW System 3.7.3 3.7 PLANT SYSTEMS 3.7.3 Auxiliary Feedwater (AFW) System LCO 3.7.3 Two AFW trains shall be OPERABLE.


NOTE ----------------------------

AFW trains required for OPERABILITY may be taken out of service under administrative control for the performance of periodic testing.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS


NOTE---------------___-___-___-___-___-_

LCO 3.0.4.b is not applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A. One steam-driven AFW A.1 Align remaining 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> pump inoperable.

OPERABLE steam-driven pump to automatic initiating status.

AND A.2 Restore steam-driven 7 days pump to OPERABLE AND status.

10 days from discovery of failure to meet the Limiting Condition for Operation (LCO)

I CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.7.3-1 Amendment No. 276 Amendment No. 2 5 3

AFW System 3.7.3 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B. One motor-driven AFW B.1 Align standby steam-72 hours pump inoperable.

driven pump to automatic initiating status.

AND B.2 Restore motor-driven 7 days pump to OPERABLE status.

AND 10 days from discovery of failure to meet the LCO C. Two AFW pumps C.1 Align remaining 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable.

OPERABLE pump to automatic initiating status.

AND C.2 Verify the other 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> unit's motor-driven AFW pump is OPERABLE.

AND C.3 Verify, by 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> administrative means, the cross-tie valve to the opposite unit is OPERABLE.

AND I

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.7.3-2 Amendment No. 276 Amendment No. 253

AC Sources-Operating 3.8.1 ACTIONS


NOTE-------------------------------------

LCO 3.0.4.b is not applicable to DGs.

CONDITION I

REQUIRED ACTION I COMPLETION TIME A. One required LCO 3.8.1.a offsite

- circuit inoperable.

A.1 Perform SR 3.8.1.1 or SR 3.8.1.2 for required OPERABLE offsite circuits.

AND A.2 Declare required feature(s) with no offsite power available inoperable when its redundant required feature(s) is inoperable.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> AND Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> from discovery of no offsite power to one train concurrent with inoperability of redundant required feature(s) 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AND 17 days from discovery of failure to meet LCO 3.8.1.a or LCO 3.8.1.b AND A.3 Restore required offsite circuit to OPERABLE status.

CALVERT CLIFFS - UNIT 1 CALVERT CLIFFS - UNIT 2 3.8.1-2 Amendment No. 276 Amendment No. 253