MONTHYEARNL-24-0031, Inservice Inspection Program Owner'S Activity Report (OAR-1) for Outage 2R232024-01-29029 January 2024 Inservice Inspection Program Owner'S Activity Report (OAR-1) for Outage 2R23 NL-24-0020, Plan, Unit 1 Responses to NRC Request for Additional Information for Refueling Outage 1R24 Steam Generator Tube Inspection Report2024-01-22022 January 2024 Plan, Unit 1 Responses to NRC Request for Additional Information for Refueling Outage 1R24 Steam Generator Tube Inspection Report NL-23-0926, Correction of Technical Specification Typographical Error2024-01-12012 January 2024 Correction of Technical Specification Typographical Error NL-23-0878, Request for Exemption from Security Event Notification Implementation2023-11-29029 November 2023 Request for Exemption from Security Event Notification Implementation NL-23-0827, Response to Requests for Additional Information for a License Amendment Request and a Proposed Alternative Related to TS 3.4.142023-11-17017 November 2023 Response to Requests for Additional Information for a License Amendment Request and a Proposed Alternative Related to TS 3.4.14 NL-23-0750, Response to Second Request for Additional Information Regarding License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the Colr2023-10-0404 October 2023 Response to Second Request for Additional Information Regarding License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the Colr NL-23-0745, Refueling Outage 1R24 Steam Generator Tube Inspection Report2023-09-22022 September 2023 Refueling Outage 1R24 Steam Generator Tube Inspection Report NL-23-0695, Response to Round 2 Request for Additional Information Regarding License Amendment Request for Technical Specification 3.8.3, Inverters Operating, Completion Time Extension (LAR-22-002S2)2023-08-31031 August 2023 Response to Round 2 Request for Additional Information Regarding License Amendment Request for Technical Specification 3.8.3, Inverters Operating, Completion Time Extension (LAR-22-002S2) NL-23-0666, License Amendment Request: Remove Combined License Appendix C (LAR 23-008)2023-08-28028 August 2023 License Amendment Request: Remove Combined License Appendix C (LAR 23-008) NL-23-0670, Response to Request for Additional Information Regarding License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the COLR Consistent with WCAP-144832023-08-11011 August 2023 Response to Request for Additional Information Regarding License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the COLR Consistent with WCAP-14483 NL-23-0658, Southern Nuclear Operating Company - Response to Request for Additional Information Regarding Quality Assurance Topical Report Submittal2023-08-11011 August 2023 Southern Nuclear Operating Company - Response to Request for Additional Information Regarding Quality Assurance Topical Report Submittal NL-23-0672, Licensee Guarantees of Payment of Deferred Premiums2023-08-10010 August 2023 Licensee Guarantees of Payment of Deferred Premiums NL-23-0542, CFR 50.46 ECCS Evaluation Model Annual Report for 20222023-08-0909 August 2023 CFR 50.46 ECCS Evaluation Model Annual Report for 2022 NL-23-0624, Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis2023-08-0404 August 2023 Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis NL-23-0611, Core Operating Limits Report, Cycle 11 Version 12023-07-19019 July 2023 Core Operating Limits Report, Cycle 11 Version 1 NL-23-0584, Preservice Inspection Program Owner'S Activity Report2023-07-10010 July 2023 Preservice Inspection Program Owner'S Activity Report NL-23-0555, Request for Exemption from Physical Barrier Requirement2023-07-0707 July 2023 Request for Exemption from Physical Barrier Requirement NL-23-0506, to Non-Voluntary License Amendment Request: Technical Specification Revision to Adopt WCAP-17661-P-A, Improved RAOC and CAOC Fq Surveillance Technical Specifications2023-07-0505 July 2023 to Non-Voluntary License Amendment Request: Technical Specification Revision to Adopt WCAP-17661-P-A, Improved RAOC and CAOC Fq Surveillance Technical Specifications NL-23-0541, Inservice Inspection Program Owners Activity Report for Outage 1R242023-06-28028 June 2023 Inservice Inspection Program Owners Activity Report for Outage 1R24 NL-23-0444, Quality Assurance Topical Report Submittal2023-06-15015 June 2023 Quality Assurance Topical Report Submittal NL-23-0339, Response to Request for Additional Information Regarding License Amendment Request for Technical Specification 3.8.3, Inverters - Operating, Completion Time Extension (LAR-22-002S1)2023-06-13013 June 2023 Response to Request for Additional Information Regarding License Amendment Request for Technical Specification 3.8.3, Inverters - Operating, Completion Time Extension (LAR-22-002S1) NL-23-0455, Report of 10 CFR 50.59 Changes, Tests, and Experiments and 10 CFR 52 Appendix D Departure Report2023-06-12012 June 2023 Report of 10 CFR 50.59 Changes, Tests, and Experiments and 10 CFR 52 Appendix D Departure Report NL-23-0467, Response to Request for Additional Information Regarding License Amendment Request: Timing of Unit 4 Technical Specifications Effectiveness Prior to Initial Criticality (LAR-23-005S1)2023-06-0909 June 2023 Response to Request for Additional Information Regarding License Amendment Request: Timing of Unit 4 Technical Specifications Effectiveness Prior to Initial Criticality (LAR-23-005S1) NL-23-0346, License Amendment Request for Exception to Regulatory Guide 1.163 (LAR 23-007)2023-05-25025 May 2023 License Amendment Request for Exception to Regulatory Guide 1.163 (LAR 23-007) NL-23-0383, SNC Response to Regulatory Issue Summary 2023-01:Preparation And.2023-05-19019 May 2023 SNC Response to Regulatory Issue Summary 2023-01:Preparation And. NL-23-0385, License Amendment Request: More Restrictive Action for Technical Specification 3.1.9 (LAR-23-006R1)2023-05-17017 May 2023 License Amendment Request: More Restrictive Action for Technical Specification 3.1.9 (LAR-23-006R1) NL-23-0398, Withdrawal of Request of License Amendment Request Regarding More Restrictive Action for Technical Specification 3.1.9 (LAR-23-006)2023-05-16016 May 2023 Withdrawal of Request of License Amendment Request Regarding More Restrictive Action for Technical Specification 3.1.9 (LAR-23-006) NL-23-0372, Units 1 & 2, Joseph M. Farley Nuclear Plant - Units 1 & 2, Vogtle Electric Generating Plant - Units 1 & 2, Annual Radiological Environmental Operating Reports for 20222023-05-10010 May 2023 Units 1 & 2, Joseph M. Farley Nuclear Plant - Units 1 & 2, Vogtle Electric Generating Plant - Units 1 & 2, Annual Radiological Environmental Operating Reports for 2022 NL-23-0360, Supplement to License Amendment Request and Exemptions to Allow Use of Lead Test Assemblies for Accident-Tolerant Fuel2023-05-0505 May 2023 Supplement to License Amendment Request and Exemptions to Allow Use of Lead Test Assemblies for Accident-Tolerant Fuel NL-23-0326, Response to Apparent Violation in NRC Inspection Report 05000424, 425/2023090; EA-22-1082023-05-0101 May 2023 Response to Apparent Violation in NRC Inspection Report 05000424, 425/2023090; EA-22-108 NL-23-0217, License Amendment Request to Revise Technical Specification Surveillance Requirement 3.4.14.1 and Proposed Inservice Testing Alternative ALT-VR-022023-05-0101 May 2023 License Amendment Request to Revise Technical Specification Surveillance Requirement 3.4.14.1 and Proposed Inservice Testing Alternative ALT-VR-02 NL-23-0330, Core Operating Limits Report, Cycle 25, Version 12023-04-26026 April 2023 Core Operating Limits Report, Cycle 25, Version 1 NL-23-0310, Annual Non-Radiological Environmental Operating Reports and Annual Radioactive Effluent Release Reports for 20222023-04-25025 April 2023 Annual Non-Radiological Environmental Operating Reports and Annual Radioactive Effluent Release Reports for 2022 NL-23-0135, License Amendment Request: Timing of Technical Specifications Effectiveness Prior to Initial Criticality (LAR-23-005)2023-04-17017 April 2023 License Amendment Request: Timing of Technical Specifications Effectiveness Prior to Initial Criticality (LAR-23-005) NL-23-0019, GEN-ISI-ALT-2023-01, Request to Use Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI2023-04-12012 April 2023 GEN-ISI-ALT-2023-01, Request to Use Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI NL-23-0152, License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the COLR Consistent with WCAP-144832023-04-11011 April 2023 License Amendment Request: Technical Specification Revision to Adopt TSTF-339-A, Relocate Technical Specification Parameters to the COLR Consistent with WCAP-14483 NL-23-0263, Southern Nuclear Company Submittal of Drug and Alcohol Testing Errors Identified 10 CFR 26.719(c) 30-Day Report2023-04-0505 April 2023 Southern Nuclear Company Submittal of Drug and Alcohol Testing Errors Identified 10 CFR 26.719(c) 30-Day Report NL-23-0136, License Amendment Request: More Restrictive Action for Technical Specification 3.1.9 (LAR-23-006)2023-04-0505 April 2023 License Amendment Request: More Restrictive Action for Technical Specification 3.1.9 (LAR-23-006) NL-23-0132, License Amendment Request: Remove Combined License Appendix C (LAR 23-001)2023-04-0404 April 2023 License Amendment Request: Remove Combined License Appendix C (LAR 23-001) NL-23-0014, Southern Nuclear Operating Co Submittal of Report on Status of Decommissioning Funding2023-03-29029 March 2023 Southern Nuclear Operating Co Submittal of Report on Status of Decommissioning Funding NL-23-0208, Independent Spent Fuel Storage Installation ISFSI, Decommissioning Funding Plan Triennial Update2023-03-29029 March 2023 Independent Spent Fuel Storage Installation ISFSI, Decommissioning Funding Plan Triennial Update NL-23-0193, Request for License Amendment: Relocation of TS 3.7.9, Spent Fuel Pool Makeup Water Sources (LAR-23-003)2023-03-24024 March 2023 Request for License Amendment: Relocation of TS 3.7.9, Spent Fuel Pool Makeup Water Sources (LAR-23-003) NL-23-0196, Response to Request for Additional Information Regarding License Amendment Request for Alternative Source Term, TSTF-51, TSTF-471, and TSTF-4902023-03-24024 March 2023 Response to Request for Additional Information Regarding License Amendment Request for Alternative Source Term, TSTF-51, TSTF-471, and TSTF-490 NL-23-0228, Nuclear Property Insurance Coverage as of April 1, 2023 and Licensee Guarantees of Payment of Deferred Premiums (10 CFR 140.21)2023-03-20020 March 2023 Nuclear Property Insurance Coverage as of April 1, 2023 and Licensee Guarantees of Payment of Deferred Premiums (10 CFR 140.21) NL-22-0977, License Amendment Request to Modify Technical Specification 5.5.11.c Acceptance Criteria for Charcoal Filter Testing2023-02-0909 February 2023 License Amendment Request to Modify Technical Specification 5.5.11.c Acceptance Criteria for Charcoal Filter Testing NL-23-0010, Response to Request for Additional Information Regarding License Amendment Request for Alternative Source Term, TSTF-51, TSTF-471, and TSTF-4902023-02-0606 February 2023 Response to Request for Additional Information Regarding License Amendment Request for Alternative Source Term, TSTF-51, TSTF-471, and TSTF-490 NL-23-0076, Exigent License Amendment Request: Technical Specification Exceptions for In-containment Refueling Water Storage Tank Operability Prior to Initial Criticality (LAR-23-004)2023-01-31031 January 2023 Exigent License Amendment Request: Technical Specification Exceptions for In-containment Refueling Water Storage Tank Operability Prior to Initial Criticality (LAR-23-004) NL-23-0013, Response to Request for Additional Information Related to 10CFR 50.75 Decommissioning Funding Assurance Requirements2023-01-30030 January 2023 Response to Request for Additional Information Related to 10CFR 50.75 Decommissioning Funding Assurance Requirements NL-23-0068, Responses to NRC Request for Additional Information Related to the Refueling Outage 2R22 Steam Generator Tube Inspection Report2023-01-27027 January 2023 Responses to NRC Request for Additional Information Related to the Refueling Outage 2R22 Steam Generator Tube Inspection Report NL-23-0012, Post-Audit Supplement to License Amendment Request and Exemptions to Allow Use of Lead Test Assemblies for Accident-Tolerant Fuel2023-01-20020 January 2023 Post-Audit Supplement to License Amendment Request and Exemptions to Allow Use of Lead Test Assemblies for Accident-Tolerant Fuel 2024-01-29
[Table view] |
Text
Don E. Grissette Southern Nuclear Vice President Operating Company, Inc.
40 lnverness Center Parkway Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.6474 Fax 205.992.0341 SOUTHERN& \
July 22, 2005 COMPANY Energy to Serve YourWorld SM Docket Nos.: 50-424 NL-05-0936 50-425 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Vogtle Electric Generating Plant Response to Request for Additional Information on Request to Revise Technical Specifications- Ultimate Heat Sink Ladies and Gentlemen:
By letter NL-04-0238 dated April 26,2004, Southern Nuclear Operating Company (SNC) submitted a proposed revision to the Vogtle Electric Generating Plant (VEGP) Unit 1 and Unit 2 Technical Specifications(TS). The proposed changes would revise the TS Limiting Conditions for Operation (LCO) 3.7.9, Ultimate Heat Sink (UHS). SNC submitted letter NL-05-0334 dated April 18, 2005, in response to a request for additional information by the NRC staff. An updated response for item three of that letter is provided in the enclosure to this letter.
A follow-up request for additional information was made by the NRC staff via a telephone conference with SNC on May 13,2005. The requested information is also provided in the enclosure to this letter.
This letter contains no NRC commitments. If you have any questions, please advise.
Don E. Grissette DEGkgVdaj Enclosure cc: Southern Nuclear Owrating Company Mr. J. T. Gasser, Executive Vice President Mr. T. E. Tynan, General Manager - Plant Vogtle RType: CVC7000 U. S . Nuclear Regulatory Commission Dr. W. D. Travers, Regional Administrator Mr. C. Gratton, NRR Project Manager - Vogtle Mr. G. J. McCoy, Senior Resident Inspector - Vogtle
Enclosure to NL-05-0936 Vogtle Electric Generating Plant - Units 1 and 2 Response to Request for Additional Information Request to Revise Technical Specifications - Ultimate Heat Sink SNC submitted letter NL-05-0334 dated April 18, 2005, in response to a request for additional information by the NRC staff. An updated response for request number three of that letter is provided below. The margin in the 63" wet-bulb limit is 0.7 degrees instead of 0.9 degrees.
- 3) NRC Request (from NL-05-0334):
Surveillance Requirement (SR) 3.7.9.5, states "Verify ambient wet-bulb temperature 5 63 O F when one NSCW tower fan is out-ofservice and daily high temperature (dry-bulb) is forecasted to be > 48 OF, at a frequency of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. What is the basis for selecting the dry-bulb temperature limit of 48 O F ? Explain how measurement uncertainties are accounted during surveillance.
Corrected SNC Response:
Surveillance of the wet-bulb temperature is not necessary when the daily forecast high temperature (dry-bulb) will be fifteen degrees less (margin) than the TS limit of 63°F. The wet-bulb temperature will not be greater than the corresponding dry-bulb temperature. Therefore, the 48°F dry-bulb temperature ensures that a fifteen degree margin exists between the forecasted daily high temperature and the TS limit of 63°F (wet-bulb). This limit eliminates the need for surveillance of the wet-bulb temperature when daily temperatures (dry-bulb) are not expected to reach 48°F.
Surveillance of the ambient temperature is necessary to ensure that 63°F (wet-bulb) is not exceeded. When ambient temperatures (dry-bulb) are greater than 48"F, daily surveillance of the wet-bulb temperature will be required to ensure that the TS limit of 63°F is not exceeded. There is a margin of 8 4 0.7 degrees in the 63°F wet-bulb limit to account for temperature measurement uncertainties.
Page 1 of 3
Enclosure to NL-05-0936 Vogtle Electric Generating Plant - Units 1 and 2 Response to Request for Additional Information Request to Revise Technical Specifications- Ultimate Heat Sink The following follow-up requests were made by the NRC staff to complete the review of the proposed revision to the Vogtle Electric Generating Plant (VEGP) Unit 1 and Unit 2 Technical Specifications (TS). The proposed changes would revise the TS Limiting Conditions for Operation (LCO) 3.7.9, Ultimate Heat Sink (UHS). These follow-up requests deal specifically with the responses provided in SNC submitted letter NL-05-0334 dated April 18,2005, in response to a request for additional information by the NRC staff. Responses to these follow-up requests are provided as follows.
- 1) NRC Request:
I n response 2 it is not clear how the licensee calculated the wet-bulb temperatures of 63 deg F and 67 deg F for one and two of four fans out of service, respectively.
SNC Response:
The four cooling tower performance curves provided in the enclosure to submittal letter NL-05-0334 dated April 18,2005, represent cooling tower performance for different temperature ranges. Each temperature range represents a specific heat load for the cooling tower. Each cooling tower, with four fans operating, is designed to reject a heat load of 265 million BTUs per hour at a flow rate of 15,600 gpm and a wet-bulb temperature of 82°F. This is the maximum heat load for the three conditions that rely on four operating fans.
These conditions are plant cool-down with a loss of off-site power, a main steam line break, and a loss-of-coolant accident. The corresponding range for this heat load is 34 degrees. The corresponding wet-bulb temperature (67°F) for three fan operation was linearly interpolated from the data on the performance curves provided in the April 18, 2005, submittal.
A fourth condition relies on three operating fans with a second fan lost from service due to a tornado missile during an LOSP. The maximum heat load for this condition is 235 million BTU per hour at a flow rate of 15,600 gpm and a wet-bulb temperature of 82°F. The corresponding range for this heat load is 30.2 degrees. The corresponding wet-bulb temperature (63°F) for two fan operation was linearly interpolated from the data on the performance curves provided in the April 18,2005, submittal.
Page 2 of 3
Enclosure to NL-05-0936 Vogtle Electric Generating Plant - Units 1 and 2 Response to Request for Additional Information Request to Revise Technical Specifications - Ultimate Heat Sink The performance curves were used to determine the reduced wet-bulb temperatures at which the heat loads described above could be met with an additional fan removed for maintenance. Tower performance data (range at 15,600 gpm) was converted to heat load. The two fan condition described above is limiting at a wet-bulb temperature of 63°F. These values are summarized in the table below.
Wet-bulb Temperature (OF)
Range (AT) Heat Load (million BTU/hr) Three Fans Two Fans 8.5 66 79.3 76.4 15.0 117 76.5 73.0 25 .O 194 72.0 66.7 30.2 (2 fans) 235 nla 63.7 34 (3 fans) 265 67.8 n/a 37.4 29 1 66.2 59.9
- 2) NRC Request:
Response 3 states that surveillance of the wet-bulb temperature is not necessary when the daily forecast of high temperature will be 15 degrees less than the TS limit of 63 deg F. Does this mean that the error limit of the daily forecast of high temperature is 15 deg F? Explain the basis for choosing a 15 deg F limit.
SNC Response:
The National Weather Service (NWS) operates a national verification program that provides feedback to forecasters. This publicly available data provides trends in forecast accuracy. The southeastern United States forecast accuracy is typically within fifteen degrees of the actual daily high temperatures. A review of nineteen months of recent data demonstrates reasonable assurance that the daily forecast high temperature is accurate to within fifteen degrees of the actual daily high temperature.
Page 3 of 3