Frequency 1.4 1.4 Frequency EXAMPLES (continued)

EXAMPLE 1.4-1 SINGLE FREQUENCY SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY Perform CHANNEL CHECK.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Example 1.4-1 contains the type of SR most often encountered in the Technical Specifications (TS). The Frequency specifies an interval (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />) during which the associated Surveillance must be performed at least one time. Performance of the Surveillance initiates the subsequent interval. Although the Frequency is stated as 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, an extension of the time interval to 1.25 times the stated Frequency is allowed by SR 3.0.2 for operational flexibility. The measurement of this interval continues at all times, even when the SR is not required to be met per SR 3.0.1 (such as when the equipment is inoperable, a variable is outside specified limits, or the unit is outside the Applicability of the LCO). If the interval specified by SR 3.0.2 is exceeded while the unit is in a MODE or other specified condition in the Applicability of the LCO, and the performance of the Surveillance is not otherwise modified (refer to Example 1.4-3), then SR 3.0.3 becomes applicable.

If the interval as specified by SR 3.0.2 is exceeded while the unit is not in a MODE or other specified condition in the Applicability of the LCO for which performance of the SR is required, then SR 3.04 becomes applicable. The Surveillance must be performed within the Frequency requirements of SR 3.0.2, as modified by SR 3.0.3, prior to entry into the MODE or other specified condition or the LCO is considered not met (in accordance with SR 3.0.1) and LCO 3.0.4 becomes applicable.

(continued)

Vogtle Units 1 and 2 1.4-2 Amendment No. 137 (Unit 1)

Amendment No. 116 (Unit 2)

LCO Applicability 3.0 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY LCO 3.0.1 LCOs shall be met during the MODES or other specified conditions in the Applicability, except as provided in LCO 3.0.2.

LCO 3.0.2 Upon discovery of a failure to meet an LCO, the Required Actions of the associated Conditions shall be met, except as provided in LCO 3.0.5 and LCO 3.0.6.

If the LCO is met or is no longer applicable prior to expiration of the specified Completion Time(s), completion of the Required Action(s) is not required unless otherwise stated.

LCO 3.0.3 When an LCO is not met and the associated ACTIONS are not met, an associated ACTION is not provided, or if directed by the associated ACTIONS, the unit shall be placed in a MODE or other specified condition in which the LCO is not applicable. Action shall be initiated within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to place the unit, as applicable, in:

a.

MODE 3 within 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />;

b.

MODE 4 within 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br />; and

c.

MODE 5 within 37 hours4.282407e-4 days <br />0.0103 hours <br />6.117725e-5 weeks <br />1.40785e-5 months <br />.

Exceptions to this Specification are stated in the individual Specifications.

Where corrective measures are completed that permit operation in accordance with the LCO or ACTIONS, completion of the actions required by LCO 3.0.3 is not required.

LCO 3.0.3 is only applicable in MODES 1, 2, 3, and 4.

LCO 3.0.4 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:

a.

When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time; or (continued)

Vogtle Units 1 and 2 3.0-1 Amendment No.1 37i (Unit 1)

Amendment No.116 (Unit 2)

LCO Applicability 3.0 3.0 LCO APPLICABILITY LCO 3.0.4 (continued)

b.

After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate; exceptions to this Specification are stated in the individual Specifications; or

c.

When an allowance is stated in the individual value, parameter, or other Specification.

This Specification shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

LCO 3.0.5 Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.

LCO 3.0.6 When a supported system LCO is not met solely due to a support system LCO not being met, the Conditions and Required Actions associated with this supported system are not required to be entered. Only the support system LCO ACTIONS are required to be entered. This is an exception to LCO 3.0.2 for the supported system. In this event, additional evaluations and limitations may be required in accordance with Specification 5.5.15, "Safety Function Determination Program (SFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.

When a support system's Required Action directs a supported system to be declared inoperable or directs entry into Conditions and Required Actions for a supported system, the applicable Conditions and Required Actions shall be entered in accordance with LCO 3.0.2.

(continued)

Vogtle Units 1 and 2 3.0-2 Amendment No.1 37 (Unit 1)

Amendment No.1 16 (Unit 2)

SR Applicability 3.0 3.0 SR APPLICABILITY SR 3.0.3 (continued)

When the Surveillance is performed within the delay period and the Surveillance is not met, the LCO must immediately be declared not met, and the applicable Condition(s) must be entered.

SR 3.0.4 Entry into a MODE or other specified condition in the Applicability of an LCO shall only be made when the LCO's Surveillances have been met within their specified Frequency, except as provided by SR 3.0.3. When an LCO is not met due to Surveillances not having been met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with LCO 3.0.4.

This provision shall not prevent entry into MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

Vogtle Units 1 and 2 3.0-5 Amendment No. 137(Unit 1)

Amendment No. 11 6(Unit 2)

SDM 3.1.1 3.1 REACTIVITY CONTROL SYSTEMS 3.1.1 SHUTDOWN MARGIN (SDM)

LCO 3.1.1 SDM shall be > the limit specified in the COLR.

APPLICABILITY:

MODES 3, 4, and 5.

ACTIONS


NOTE---------------------------------------------------------

While this LCO is not met, transition to a lower MODE within the Applicability is not permitted.

CONDITION REQUIRED ACTION COMPLETION TIME A.

SDM not within limit.

A.1 Initiate boration to restore 15 minutes SDM to within limit.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.1.1.1 Verify SDM is > the limit specified in the COLR.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Vogtle Units 1 and 2 3.1.1-1 Amendment No.137 (Unit 1)

Amendment No.116 (Unit 2)

RTS Instrumentation 3.3.1 3.3 INSTRUMENTATION 3.3.1 Reactor Trip System (RTS) Instrumentation LCO 3.3.1 The RTS instrumentation for each Function in Table 3.3.1-1 shall be OPERABLE.

APPLICABILITY:

According to Table 3.3.1-1.

ACTIONS


NOTI Separate Condition entry is allowed for each Function

?---.__-_--

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more Functions A.1 Enter the Condition Immediately with one or more referenced in required channels Table 3.3.1-1 for the inoperable.

channel(s).

B. One Manual Reactor Trip B.1 Restore channel to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> channel inoperable.

OPERABLE status.

OR B.2 Be in MODE 3.

54 hours6.25e-4 days <br />0.015 hours <br />8.928571e-5 weeks <br />2.0547e-5 months <br /> C.


NOTE--------------

C.1 Restore channel or train 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> While this LCO is not met to OPERABLE status.

for Functions 1, 17, 18, or 19 in MODES 3, 4, OR or 5, closing the reactor trip breakers is not C.2 Open RTBs.

49 hours5.671296e-4 days <br />0.0136 hours <br />8.101852e-5 weeks <br />1.86445e-5 months <br /> permitted.

One channel or train inoperable.

(continued)

Vogtle Units 1 and 2 3.3.1-1 Amendment No. 137(Unit 1)

Amendment No. 11 6(Unit 2)

PAM Instrumentation 3.3.3 3.3 INSTRUMENTATION 3.3.3 Post Accident Monitoring (PAM) Instrumentation LCO 3.3.3 APPLICABILITY:

The PAM instrumentation for each Function in Table 3.3.3-1 shall be OPERABLE.

MODES 1,2, and 3.

ACTIONS NOTE----

Separate Condition entry is allowed for each Function.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more functions A.1 Enter the applicable Immediately with one or more Condition referenced in required channels Table 3.3.3-1 for the inoperable.

channels.

B. -----------NOTE------------

B.1 Restore the channel to 30 days For containment OPERABLE status.

isolation valve position indication, separate Condition entry is allowed for each

-penetration flow path.

One required channel inoperable.

(continued)

Vogtle Units 1 and 2 3.3.3-1 Amendment No.1 37(Unit 1)

Amendment No.1 1 6(Unit 2)

Remote Shutdown System 3.3.4 3.3 INSTRUMENTATION 3.3.4 Remote Shutdown System LCO 3.3.4 The Remote Shutdown System Functions in Table 3.3.4-1 shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS


NOT Separate Condition entry is allowed for each Fun t-------------------_______________________________-

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more required A.1 Restore required Function 30 days Functions inoperable.

to OPERABLE status.

B.

Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND B.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Vogtle Units 1 and 2 3.3.4-1 Amendment No.1 37(Unit 1)

Amendment No. 1 16(Unit 2)

High Flux at Shutdown Alarm 3.3.8 3.3 INSTRUMENTATION 3.3.8 High Flux at Shutdown Alarm (HFASA)

LCO 3.3.8 APPLICABILITY:

Two channels of HFASA shall be OPERABLE.

MODES 3,4, and 5 KIP. C B

-JULl, I = -----------------------------------------

The HFASA may be blocked in MODE 3 during reactor startup.

ACTIONS COMPLETION CONDITION REQUIRED ACTION TIME A.

One channel of HFASA A.1


NOTE----------------

Inoperable.

LCO 3.0.4c is applicable provided Required Actions B.1 and B.2 are met.

Restore channel to OPERABLE 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> status.

B. Required Action and B.1 Perform SR 3.1.1.1 (verify 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> associated Completion SDM).

Time of Condition A not AND met.

Once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> thereafter OR Two channels of AND HFASA inoperable.

B.2 Perform SR 3.9.2.1 (verify 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> unborated water source isolated).

AND Once per 14 days thereafter Vogtle Units 1 and 2 3.3.8-1 Amendment No. 137 (Unit 1)

Amendment No. 116 (Unit 2)

RCS Loops -

MODE 5, Loops Not Filled 3.4.8 I

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One RHR loop inoperable.

A.1 Initiate action to restore Immediately RHR loop to OPERABLE status.

B.

Required RHR loops B.1 Suspend all operations Immediately inoperable.

involving reduction in RCS boron concentration.

OR AND No RHR loop in operation.

B.2 Initiate action to restore Immediately one RHR loop to OPERABLE status and to operation.

C. One or more valves used C.1 Initiate action to secure Immediately to isolate unborated water valve(s) in closed sources not secured in position.

closed position.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.8.1 Verify one RHR loop is in operation.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SR 3.4.8.2 Verify correct breaker alignment and indicated power 7 days are available to the required RHR pump that is not in operation.

SR 3.4.8.3 Verify each valve that isolates unborated water 31 days sources is secured in the closed position.

Vogtle Units 1 and 2 3.4.8-2 Amendment No.1 37 (Unit 1)

Amendment No.1 16 (Unit 2)

Pressurizer PORVs 3.4.11 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.11 Pressurizer Power Operated Relief Valves (PORVs)

LCO 3.4.11 APPLICABILITY:

Each PORV and associated block valve shall be OPERABLE.

MODES 1, 2, and 3.

ACTIONS NOT Separate Condition entry is allowed for each POF CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more PORVs A.1 Close and maintain power 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable and capable to associated block valve.

of being manually cycled.

B. One PORV inoperable B.1 Close associated block 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and not capable of being valve.

manually cycled.

AND B.2 Remove power from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> associated block valve.

AND B.3 Restore PORV to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> OPERABLE status.

(continued)

Vogtle Units 1 and 2 3.4.11-1 Amendment No.1 37(Unit 1)

Amendment No 1 6 (Unit 2)

COPS 3.4.12 ACTIONS NOTES--------------------------------------------------------------

1.

LCO 3.0.4b is not applicable for entry in MODE 4, entry into MODE 6 with the reactor vessel head on from MODE 6, and entry into MODE 5 from MODE 6 with the reactor vessel head on.

2.

With one required PORV inoperable for the purpose of cold overpressure protection, entry into MODE 4 from MODE 3 is permitted provided that RCS temperature is maintained above 2750F, and, within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />, either: the PORV is restored to OPERABLE status; or, an RHR suction relief valve is placed in service so that the requirements of LCO 3.4.12 are met. Otherwise, the reactor vessel must be depressurized and vented in accordance with Required Action F.1.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more safety A.1 Render all safety injection 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> injection pumps capable pumps incapable of injecting of injecting into the RCS.

into the RCS.

B.

An accumulator not B.1 Isolate affected accumulator.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> isolated when the accumulator pressure is greater than or equal to the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.

C.

Required Action and C.1 Increase RCS cold leg 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion temperature to > 3500F.

Time of Condition B not met.

OR C.2 Depressurize affected 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> accumulator to less than the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.

D.

One required RCS relief D.1 Restore required RCS relief 7 days valve inoperable in valve to OPERABLE status.

MODE 4.

(continued)

Vogtle Units 1 and 2 3.4.12-2 Amendment No. 137 (Unit 1)

Amendment No. 1 16 (Unit 2)

RCS Leakage Detection Instrumentation 3.4.15 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.15 RCS Leakage Detection Instrumentation LCO 3.4.15 The following RCS leakage detection instrumentation shall be OPERABLE:

a.

The containment normal sumps level and reactor cavity sump monitors;

b.

One containment atmosphere radioactivity monitor (gaseous or particulate); and

c.

Either the containment air cooler condensate flow rate or a containment atmosphere gaseous or particulate radioactivity monitoring system not taken credit for in item b.

APPLICABILITY:

MODES 1, 2,3, and 4.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One containment sump A.1 Perform SR 3.4.13.1.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> monitor inoperable.

B. Two or more B.1 Perform SR 3.4.13.1 Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> containment sump monitors inoperable AND B.2 Restore at least two 30 days containment sump monitors to OPERABLE status.

(continued)

I I

Vogtle Units 1 and 2 3.4.15-1 Amendment No;1 37 (Unit 1)

Amendment No.1 16 (Unit 2)

RCS Leakage Detection Instrumentation 3.4.15 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C.

Required containment C.1.1 Analyze grab samples of Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> atmosphere radioactivity the containment monitor(s) inoperable.

atmosphere.

OR C.1.2 Perform SR 3.4.13.1.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> AND C.2.1 Restore required 30 days containment atmosphere radioactivity monitor(s) to OPERABLE status.

OR C.2.2 Verify containment air 30 days cooler condensate flow rate monitor is OPERABLE.

D.

Required containment D.1 Perform SR 3.4.15.2.

Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> air cooler condensate flow rate monitor OR inoperable.

D.2 Perform SR 3.4.13.1.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (continued)

I Vogtle Units 1 and 2 3.4.15-2 Amendment No.137 (Unit 1)

Amendment No.116 (Unit 2)

RCS Specific Activity 3.4.16 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.16 RCS Specific Activity LCO 3.4.16 APPLICABILITY:

The specific activity of the reactor coolant shall be within limits.

MODES 1 and 2, MODE 3 with RCS average temperature (Tavg) 2 5000F.

ACTIONS

-NOTE-LCO 3.0.4c is applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A.

DOSE EQUIVALENT A.1 Verify DOSE Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 1-131 > 1.0 gCi/gm.

EQUIVALENT 1-131 within the acceptable region of Figure 3.4.16-1.

AND A.2 Restore DOSE 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> EQUIVALENT 1-131 to within limit.

B.

Gross specific activity of B.1 Perform SR 3.4.16.2.

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> the reactor coolant not within limit.

AND B.2 Be in MODE 3 with 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> TavEg < 5001F.

(continued)

Vogtle Units 1 and 2 3.4.16-1 Amendment No.1 37(Unit 1)

Amendment No.1 16(Unit 2)

ECCS - Shutdown 3.5.3 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) 3.5.3 ECCS - Shutdown LCO 3.5.3 APPLICABILITY:

One ECCS train shall be OPERABLE.

MODE 4.

ACTIONS


NOTE-------------------------------------------------------

LCO 3.0.4b is not applicable to ECCS centrifugal charging pump subsystem.

CONDITION REQUIRED ACTION COMPLETION TIME A.

Required ECCS residual A.1 Initiate action to restore Immediately heat removal (RHR) required ECCS RHR subsystem inoperable.

subsystem to OPERABLE status.

B.

Required ECCS B.1 Restore required ECCS 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> centrifugal charging centrifugal charging subsystem inoperable.

subsystem to OPERABLE status.

AND At least 100% of the ECCS flow equivalent to a single OPERABLE ECCS train available.

C.

Required ECCS C.1 Restore required ECCS 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> centrifugal charging centrifugal charging subsystem inoperable.

subsystem to OPERABLE status.

D. Required Actions and D.1 Be in MODE 5.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> associated Completion Times of Conditions B or C not met.

Vogtle Units 1 and 2 3.5.3-1 Amendment No.1 37(Unit 1)

Amendment No.1 16 (Unit 2)

ARVs 3.7.4 3.7 PLANT SYSTEMS 3.7.4 Atmospheric Relief Valves (ARVs)

LCO 3.7.4 Three ARV lines shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One required ARV line A.1 Restore required ARV line 30 days inoperable.

to OPERABLE status.

B. Two or more required B.1 Restore at least two ARV 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> ARV lines inoperable.

lines to OPERABLE status.

C. Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND C.2 Be in MODE 4 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> I

Vogtle Units 1 and 2 3.7.4-1 AmendmentNo. 137 (Unit 1)

Amendment No. 116 (UWit 2)

AFW System 3.7.5 3.7 PLANT SYSTEMS 3.7.5 Auxiliary Feedwater (AFW) System LCO 3.7.5 APPLICABILITY:

Three AFW trains shall be OPERABLE.

MODES 1, 2, and 3.

ACTIONS NOTE-LCO 3.0.4b is not applicable when entering MODE 1.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One steam supply to A.1 Restore steam supply to 7 days turbine driven AFW OPERABLE status.

pump inoperable.

AND 10 days from discovery of failure to meet the LCO B.

One AFW train B.1 Restore AFW train to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> inoperable for reasons OPERABLE status.

other than Condition A.

AND 10 days from discovery of failure to meet the LCO (continued)

Vogtle Units 1 and 2 3.7.5-1 Amendment No.137(Unit 1)

Amendment No.116 (Unit 2)

UHS 3.7.9 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. One NSCW basin C.1 Restore the transfer 8 days transfer pump pump to OPERABLE inoperable.

status.

OR C.2.1 Implement an alternate 8 days method of basin transfer.

AND C.2.2 Restore the transfer 31 days pump to OPERABLE status.

D. Required Action and D.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND OR D.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> UHS inoperable for reasons other than Conditions A, B, or C.

I Vogtle Units 1 and 2 3.7.9-2 Amendment No. 137 (Unit 1)

AmendmentNo. 116 (Unit 2)

CREFS - Both Units Operating 3.7.10 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E.

Control room air E.1 Restore control room air 7 days temperature not within temperature to within limit.

limit.

F.

Required Action and F.1


NOTE-------------

associated Completion Required Action F.1 is not Time not met.

applicable when entering this Condition from Condition B, D, or E.

Lock closed the outside air 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (OSA) intake dampers of the affected unit and lock open the OSA intake dampers of the unaffected unit.

AND F.2 Place the affected units(s) 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> in MODE 3.

AND F.3 Place the affected unit(s) 37 hours4.282407e-4 days <br />0.0103 hours <br />6.117725e-5 weeks <br />1.40785e-5 months <br /> in MODE 5.

Vogtle Units 1 and 2 3.7.10-2 Amendment No. 137 (Unit 1)

Amendment No. 11 6 (Unit 2)

CREFS - One Unit Operating 3.7.11 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME G.

Control room air G.l Restore control room air 7 days temperature not within temperature to within limit.

limit.

H. Required Action and H.1 Place the unit in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met for AND operating unit.

H.2 Place the unit in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.11.1 The Surveillance Requirements of Specification In accordance with 3.7.10 are applicable.

applicable SRs.

I Vogtle Units 1 and 2 3.7.11-3 Amendment No. 137 (Unit 1)

Amendment No. 1 16 (Unit 2)

CREFS - Both Units Shutdown 3.7.12 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E.

Four CREFS trains E.A Suspend movement of Immediately inoperable.

irradiated fuel OR assemblies.

The CREFS train AND required in the emergency mode by E.2 Suspend CORE Immediately Required Actions of ALTERATIONS.

Conditions A, B, C, or D not capable of being powered by an OPERABLE emergency power source.

F.

Control room air F.1 Restore control room air 7 days temperature not within temperature to within limit.

limit.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.12.1 The Surveillance Requirements of In accordance with Specification 3.7.10 are applicable.

applicable SRs.

I Vogtle Units 1 and 2 3.7.12-3 Amendment No. 1 37(Unit 1)

Amendment No. 11 6(Unit 2)

AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS 3.8.1 AC Sources - Operating LCO 3.8.1 The following AC electrical sources shall be OPERABLE:

a.

Two qualified circuits between the offsite transmission network and the onsite Class 1 E AC Electrical Power Distribution System; and

b.

Two diesel generators (DGs) capable of supplying the onsite Class 1 E power distribution subsystem(s).

Automatic load sequencers for Train A and Train B ESF buses shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTIONS

-NOTE-LCO 3.0.4b is not applicable to DGs.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One required offsite A.1 Perform SR 3.8.1.1 for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> circuit inoperable.

required OPERABLE offsite circuit.

AND Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter AND (continued)

VogUe Units 1 and 2 3.8.1-1 Amendment No. 137(Unit 1)

Amendment No. 11 6(Unit 2)

Boron Concentration 3.9.1 3.9 REFUELING OPERATIONS 3.9.1 Boron Concentration LCO 3.9.1 APPLICABILITY:

Boron concentrations of the Reactor Coolant System, the refueling canal, and the refueling cavity shall be maintained within the limit specified in the COLR.

MODE 6.

ACTIONS I

CONDITION REQUIRED ACTION COMPLETION TIME A.

Boron concentration not A.1 Suspend CORE Immediately within limit.

ALTERATIONS.

AND A.2 Suspend positive Immediately reactivity additions.

AND A.3 Initiate action to restore Immediately boron concentration to within limit.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.9.1.1 Verify boron concentration is within the limit 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> specified in the COLR.

Vogtle Units 1 and 2 3.9.1-1 Amendment No. 137 (Unit 1)

Amendment No. 116 (Unit 2)

RHR and Coolant Circulation - Low Water Level 3.9.6 3.9 REFUELING OPERATIONS 3.9.6 Residual Heat Removal (RHR) and Coolant Circulation - Low Water Level LCO 3.9.6 APPLICABILITY:

Two RHR loops shall be OPERABLE, and one RHR loop shall be in operation.

MODE 6 with the water level < 23 ft above the top of reactor vessel flange.

ACTIONS I

CONDITION REQUIRED ACTION COMPLETION TIME A.

Less than the required A.1 Initiate action to restore Immediately number of RHR loops required RHR loops to OPERABLE.

OPERABLE status.

OR A.2 Initiate action to Immediately establish > 23 ft of water above the top of reactor vessel flange.

B. No RHR loop in operation.

B.1 Suspend operations Immediately involving a reduction in reactor coolant boron concentration.

AND (continued)

Vogtle Units 1 and 2 3.9.6-1 Amendment No.1 37(Unit 1)

Amendment No.11 6(Unit 2)