COPS 3.4.12 ACTIONS NOTE-------------------
LCO 3.0.4b is not applicable for entry into MODE 4, entry into MODE 6 with reactor vessel head on from MODE 6, and entry into MODE 5 from MODE 6 with the reactor vessel head on.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more safety A.1 Render all safety injection 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> injection pumps capable pumps incapable of injecting of injecting into the RCS.
into the RCS.
B. An accumulator not B.1 Isolate affected accumulator.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> isolated when the accumulator pressure is greater than or equal to the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.
C. Required Action and C.1 Increase RCS cold leg 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion temperature to > the COPS Time of Condition B not arming temperature specified met.
in the PTLR.
OR C.2 Depressurize affected 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> accumulator to less than the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.
D.
One required RCS relief D.1 Restore required RCS relief 7 days valve inoperable in valve to OPERABLE status.
MODE 4 with any RCS cold leg temperature s the COPS arming temperature specified in the PTLR.
(continued)
Vogtle Units I and 2 3.4.12-2 Amendment No. 137 (Unit 1)
Amendment No. 116 (Unit 2)