MONTHYEARIR 05000354/20240032024-10-23023 October 2024 Integrated Inspection Report 05000354/2024003 ML24295A3742024-10-23023 October 2024 Project Manager Assignment ML24291A0572024-10-17017 October 2024 License Amendment Request (LAR) – Hope Creek Technical Specification Conversion to NUREG-1433, Revision 5, Supplement 1 LR-N24-0063, Emergency Plan Document Revision Implemented September 18, 2024. Includes NC.EP-EP.ZZ-0903, Rev. 7, Opening of Emergency Operations Facility (EOF)2024-10-0707 October 2024 Emergency Plan Document Revision Implemented September 18, 2024. Includes NC.EP-EP.ZZ-0903, Rev. 7, Opening of Emergency Operations Facility (EOF) LR-N24-0059, 2024 Annual 10 CFR 50.46 Report2024-09-30030 September 2024 2024 Annual 10 CFR 50.46 Report LR-N24-0056, Response to Request for Additional Information Associated with License Amendment Request - Revise Hope Creek Generating Station Technical Specification to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle2024-09-26026 September 2024 Response to Request for Additional Information Associated with License Amendment Request - Revise Hope Creek Generating Station Technical Specification to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle IR 05000272/20244022024-09-23023 September 2024 And Salem Nuclear Generating Station, Units 1 and 2 - Security Baseline Inspection Report 05000354/2024402, 05000272/2024402, and 05000311/2024402 (Cover Letter Only) ML24255A8042024-09-11011 September 2024 Notification of Conduct of a Fire Protection Team Inspection LR-N24-0057, In-Service Inspection Activities2024-09-10010 September 2024 In-Service Inspection Activities 05000354/LER-2024-001-01, Invalid Primary Containment Integrated Leak Rate As-Found Test (ILRT) Supplement2024-09-0505 September 2024 Invalid Primary Containment Integrated Leak Rate As-Found Test (ILRT) Supplement ML24249A1362024-09-0404 September 2024 EN 57304 - Westinghouse Electric Company, LLC, Final Report - No Embedded Files. Notification of the Potential Existence of Defects Pursuant to 10 CFR Part 21 IR 05000354/20240052024-08-29029 August 2024 Updated Inspection Plan for Hope Creek Generating Station (Report 05000354/2024005) LR-N24-0044, Relief Request VR-042024-08-0606 August 2024 Relief Request VR-04 IR 05000354/20240022024-07-30030 July 2024 Integrated Inspection Report 05000354/2024002 ML24200A0572024-07-18018 July 2024 Request for Withholding Information from Public Disclosure for License Amendment Request to Revise Technical Specification Lift Settings for Reactor Coolant System Safety/Relief Valves NUREG-1433, – Acceptance of License Amendment Request Concerning Technical Specification Conversion to NUREG-1433, Revision 52024-07-16016 July 2024 – Acceptance of License Amendment Request Concerning Technical Specification Conversion to NUREG-1433, Revision 5 ML24145A1772024-07-15015 July 2024 And Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Issuance of Amendment Nos. 236, 349, and 331 Modify Exclusion Area Boundary ML24197A0552024-07-15015 July 2024 Requalification Program Inspection 05000354/LER-2024-001, Invalid Primary Containment Integrated Leak Rate As-Found Test (ILRT)2024-07-0202 July 2024 Invalid Primary Containment Integrated Leak Rate As-Found Test (ILRT) LR-N24-0030, License Amendment Request to Revise Technical Specification Lift Settings for Reactor Coolant System Safety/Relief Valves2024-06-28028 June 2024 License Amendment Request to Revise Technical Specification Lift Settings for Reactor Coolant System Safety/Relief Valves IR 05000272/20245012024-06-12012 June 2024 And Salem Nuclear Generating Station, Units 1 and 2 - Emergency Preparedness Biennial Exercise Inspection Report 05000354/2024501, 05000272/2024501 and 05000311/2024501 ML24150A1002024-05-28028 May 2024 Core Operating Limits Report, Reload 25, Cycle 26, Revision 23 ML24150A0032024-05-28028 May 2024 Request for Exemptions from 10 CFR 50.82(a)(8)(i)(A) and 10 CFR 50.75(h)(1)(iv) and Proposed Amendment to the Decommissioning Trust Agreement LR-N24-0041, Stations, Revisions to Emergency Plan Document Nc EP-EP-ZZ-01102, Rev. 28, Emergency Coordinator Response2024-05-22022 May 2024 Stations, Revisions to Emergency Plan Document Nc EP-EP-ZZ-01102, Rev. 28, Emergency Coordinator Response ML24142A4072024-05-20020 May 2024 License Amendment Request (LAR) - Hope Creek Technical Specification Conversion to NUREG-1433, Revision 5 LR-N24-0004, License Amendment Request – Revise Technical Specification to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle2024-05-20020 May 2024 License Amendment Request – Revise Technical Specification to Change Surveillance Intervals to Accommodate a 24-Month Fuel Cycle IR 05000354/20240012024-05-0808 May 2024 Integrated Inspection Report 05000354/2024001 IR 05000354/20240102024-05-0707 May 2024 Information Request for Quadrennial Baseline Comprehensive Engineering Team Inspection; Notification to Perform Inspection 05000354/2024010 LR-N24-0035, 2023 Annual Radiological Environmental Operating Report (AREOR)2024-04-30030 April 2024 2023 Annual Radiological Environmental Operating Report (AREOR) LR-N24-0034, 2023 Annual Radioactive Effluent Release Report (ARERR)2024-04-30030 April 2024 2023 Annual Radioactive Effluent Release Report (ARERR) LR-N24-0024, Response to Request for Additional Information Associated with License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary2024-04-26026 April 2024 Response to Request for Additional Information Associated with License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary IR 05000354/20243012024-04-10010 April 2024 Initial Operator Licensing Examination Report 05000354/2024301 LR-N24-0011, Supplemental Information to License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary2024-04-0505 April 2024 Supplemental Information to License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary IR 05000272/20240112024-04-0101 April 2024 And Salem Nuclear Generating Station, Units 1 and 2 - Plant Modification and Annual Problem Identification and Resolution Inspection Report 05000354/2024011, 05000272/2024011, and 05000311/2024011 LR-N24-0028, And Salem Generating Station - Notice of Intent to Pursue Subsequent License Renewal2024-03-28028 March 2024 And Salem Generating Station - Notice of Intent to Pursue Subsequent License Renewal LR-N24-0021, And Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums2024-03-20020 March 2024 And Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums IR 05000272/20244032024-03-20020 March 2024 And Hope Creek Generating Station - Information Request for the Cybersecurity Baseline Inspection, Notification to Perform Inspection 05000272/2024403, 05000311/2024403, and 05000354/2024403 05000354/LER-2023-003-01, Inadvertent Main Turbine Control Valve Closure Caused Reactor Scram2024-03-19019 March 2024 Inadvertent Main Turbine Control Valve Closure Caused Reactor Scram LR-N24-0027, Inadvertent Main Turbine Control Valve Closure Caused Reactor Scram2024-03-19019 March 2024 Inadvertent Main Turbine Control Valve Closure Caused Reactor Scram LR-N24-0020, Generation Station and Salem Generating Station, Units 1 & 2 - Annual Property Insurance Status Report2024-03-0707 March 2024 Generation Station and Salem Generating Station, Units 1 & 2 - Annual Property Insurance Status Report IR 05000354/20230062024-02-28028 February 2024 Annual Assessment Letter for Hope Creek Generating Station (Report 05000354/2023006) IR 05000272/20244012024-02-26026 February 2024 And Salem Nuclear Generating Station, Units 1 and 2 - Security Baseline Inspection Report 05000354/2024401, 05000272/2024401 and 05000311/2024401 (Cover Letter Only) LR-N24-0010, Technical Specification 6.9.1.5.b: 2023 Annual Report of SRV Challenges2024-02-22022 February 2024 Technical Specification 6.9.1.5.b: 2023 Annual Report of SRV Challenges 05000354/LER-2023-003, Inadvertent Main Turbine Control Valve Closure Caused Reactor Scram2024-02-12012 February 2024 Inadvertent Main Turbine Control Valve Closure Caused Reactor Scram ML24030A8752024-02-0101 February 2024 Operator Licensing Examination Approval IR 05000354/20230042024-02-0101 February 2024 Integrated Inspection Report 05000354/2023004 ML24009A1022024-01-26026 January 2024 – Exemption from Select Requirements of 10 CF Part 73 (EPID L-2023-LLE-0045 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) IR 05000354/20234012024-01-22022 January 2024 Material Control and Accounting Program Inspection Report 05000354/2023401 ML23341A1372024-01-16016 January 2024 Issuance of Amendment No. 235 Revise Trip and Standby Auto-Start Logic Associated with Safety Related Heating, Ventilation and Air Conditioning ML23335A1122023-12-15015 December 2023 Retest Schedule for Drywell to Suppression Chamber Vacuum Breakers 2024-09-05
[Table view] Category:Proprietary Information Review
MONTHYEARML24200A0572024-07-18018 July 2024 Request for Withholding Information from Public Disclosure for License Amendment Request to Revise Technical Specification Lift Settings for Reactor Coolant System Safety/Relief Valves ML21153A1032021-06-0909 June 2021 Request for Withholding Information from Public Disclosure ML21124A1222021-05-13013 May 2021 Request for Withholding Information from Public Disclosure ML20310A1252020-11-19019 November 2020 Request for Withholding Information from Public Disclosure ML18038B1022018-02-21021 February 2018 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML18011A0352018-01-11011 January 2018 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station (CAC No. MF9930; EPID L-2017-LLA-0426) ML17321A0682017-11-28028 November 2017 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station (CAC No. MF9502; EPID L-2017-LLA-0204) ML17235B1202017-08-28028 August 2017 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML17201A0462017-07-24024 July 2017 Request for Withholding Information from Public Disclosure ML16200A2532016-08-0202 August 2016 08/02/2016 NRC Approval of Request for Withholding Information from Public Disclosure ML15112B1362015-05-26026 May 2015 Request for Withholding Information from Public Disclosure Hope Creek Generating Station ML15027A5922015-02-0202 February 2015 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML14126A8302014-06-0303 June 2014 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML14085A3252014-05-15015 May 2014 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML14073A0422014-03-28028 March 2014 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1207405722012-03-29029 March 2012 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1135003492012-01-11011 January 2012 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1028505142010-10-19019 October 2010 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1023903302010-09-0909 September 2010 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1023903432010-09-0909 September 2010 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1018303302010-07-14014 July 2010 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1013303612010-06-0303 June 2010 Letter Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML1002607732010-02-0404 February 2010 Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0828105572008-10-10010 October 2008 Westinghouse Electric Co., Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0825506122008-09-18018 September 2008 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station (Hope Creek) Regarding Letter, Dated Sept. 2, 2008,License Condition 2.C.(22)2.b,for Hope Creek Extended Power Uprate (TAC No. MD ML0814200492008-05-22022 May 2008 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek, Generating Station Regarding Letter, Dated May 19, 2008, License Conditions 2.C.(21), 2.C.(22)2.g and 2.C.(22)3 ML0803104672008-03-0707 March 2008 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Regarding Letter Dated January 25, 2008, Responses to Requests for Additional Information Request for License Amendment - Extended Power Uprate. ML0803108682008-02-15015 February 2008 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station Regarding Letter, Dated 01/30/2008, Responses to Requests for Additional Information Request for License Amendment-Extended Power ML0803108582008-02-15015 February 2008 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Regarding Letter, Dated January 30, 2008, Responses to Requests for Additional Information Request for License Amendment--Extended Power Uprate ML0802304872008-02-0101 February 2008 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station Letter, Dated January 18, 2008, Responses to Requests for Additional Information Request for License Amendment - Extended Power U ML0801501272008-01-24024 January 2008 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station Regarding Letter, Dated December 31, 2007, Subject: Continuum Dynamics, Incorporated Report No. 07-27P, Finite Element Modeling B ML0802304792008-01-0101 January 2008 Request for Withholding Information, Continuum Dynamics, Incorporated Report No. 07-17P, Stress Assessment of Hope Creek, Unit 1, Steam Dryer Based on Revision 4 Loads Model, Rev 3, Dated Jan 2008 ML0726301542007-10-0101 October 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station Regarding Letter, Dated August 3, 2007, Subject: Response to Request for Additional Information Request for License Amendment - E ML0726101122007-09-24024 September 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Regarding Letter, Dated September 11, 2007, Subject: Revised CDI Report 07-17P, Stress Assessment of Hope Creek, Unit 1, Steam Dryer Based on Revisi ML0724308002007-09-24024 September 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station Regarding Slides Presented at a Public Meeting, Dated August 17, 2007 (TAC No. MD3002.` ML0715604492007-07-0303 July 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0717904442007-07-0303 July 2007 PSEG Nuclear Request for Withholding Information from Public Disclosure for Hope Creek Generating Station (MD3002) ML0717004062007-07-0303 July 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0713502112007-07-0303 July 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0712404992007-06-0606 June 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0713006152007-06-0606 June 2007 Withholding from Public Disclosure, Transmittal - Proprietary Content of Hope Creek Letter, LCR H05-01, Rev. 1 - RAIs 11.1 and 3.5d, Enclosure 1 of the GE-HCGS-EPU-668 ML0713006042007-06-0606 June 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0712405102007-05-17017 May 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0712404612007-05-17017 May 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0628605302007-05-17017 May 2007 Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0712404872007-05-0909 May 2007 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0628304532006-11-21021 November 2006 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station ML0628304722006-11-0808 November 2006 PSEG Nuclear LLC, Withholding from Public Disclosure, NEDC-33076P, Revision 2, Safety Analysis Report for Hope Creek Constant Pressure Power Uprate, Class III, MD3002 ML0600400602006-01-10010 January 2006 PSEG Nuclear LLC, Withholding from Public Disclosure, Mixed Core Analysis Report (Mcar) for Hope Creek Reload 12 Cycle 13, Revision 0 ML0600402222006-01-10010 January 2006 PSEG Nuclear LLC, Request for Withholding Information from Public Disclosure for Hope Creek Generating Station 2024-07-18
[Table view] |
Text
July 14, 2005 Mr. Bradley J. Erbes Manager, Systems Engineering Services GE Nuclear Energy 175 Curtner Avenue M/C 747 San Jose, CA 95125
SUBJECT:
PSEG NUCLEAR LLC, REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE FOR HOPE CREEK GENERATING STATION
Dear Mr. Erbes:
By letter dated May 20, 2005, PSEG Nuclear LLC (PSEG) submitted an affidavit dated May 5, 2005, executed by you, requesting that the information contained in the following document be withheld from public disclosure pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Part 2, Section 2.390:
Enclosure 2 to GE [General Electric] letter, GE-HCGS-AM-086, GE Responses to NRC [Nuclear Regulatory Commission] RAIs [requests for additional information] 1e and 1h, dated May 5, 2005 The May 20, 2005, letter from PSEG contained responses to NRC questions related to PSEGs license change request H04-01 for the Hope Creek Generating Station. The letter from PSEG stated that the proprietary information from the aforementioned GE letter was faithfully reproduced in the submitted letter such that the affidavit remains applicable.
A nonproprietary copy of this document has been placed in the NRC's Public Document Room and added to the Agencywide Documents Access and Management System Public Electronic Reading Room.
The affidavit stated that the submitted information should be considered exempt from mandatory public disclosure for the following reasons:
(1) This information is of the type typically held in confidence by GE, and is in fact so held.
(2) The information is being transmitted to the NRC in confidence.
(3) The information has not been publically disclosed, nor is it available in public sources.
(4) The information discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by GEs competitors constitutes a competitive economic advantage over other companies.
B. Erbes (5) The information, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.
(6) Public disclosure of this information would cause GE to lose its competitive advantage if its competitors were able to use the results to normalize or verify their own process or if they were able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.
We have reviewed your application and the material in accordance with the requirements of 10 CFR 2.390 and, on the basis of your statements, have determined that the submitted information sought to be withheld contains proprietary commercial information and should be withheld from public disclosure.
Therefore, the version of the submitted information marked as proprietary will be withheld from public disclosure pursuant to 10 CFR 2.390(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as amended.
Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents. If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information.
If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You should also understand that the NRC may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information. In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.
If you have any questions regarding this matter, I may be reached at 301-415-1321.
Sincerely,
/RA/
Stewart N. Bailey, Senior Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-354 cc: See next page
B. Erbes Hope Creek Generating Station cc:
Mr. Michael P. Gallagher Jeffrie J. Keenan, Esquire Vice President - Eng/Tech Support PSEG Nuclear - N21 PSEG Nuclear P.O. Box 236 P.O. Box 236 Hancocks Bridge, NJ 08038 Hancocks Bridge, NJ 08038 Ms. R. A. Kankus Mr. Michael Brothers Joint Owner Affairs Vice President - Nuclear Assessments Exelon Generation Company, LLC PSEG Nuclear Nuclear Group Headquarters KSA1-E P.O. Box 236 200 Exelon Way Hancocks Bridge, NJ 08038 Kennett Square, PA 19348 Mr. George P. Barnes Lower Alloways Creek Township Site Vice President - Hope Creek c/o Mary O. Henderson, Clerk PSEG Nuclear Municipal Building, P.O. Box 157 P.O. Box 236 Hancocks Bridge, NJ 08038 Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Mr. George H. Gellrich Radiation Protection Programs Plant Support Manager NJ Department of Environmental PSEG Nuclear Protection and Energy P.O. Box 236 CN 415 Hancocks Bridge, NJ 08038 Trenton, NJ 08625-0415 Mr. Michael J. Massaro Brian Beam Plant Manager - Hope Creek Board of Public Utilities PSEG Nuclear 2 Gateway Center, Tenth Floor P.O. Box 236 Newark, NJ 07102 Hancocks Bridge, NJ 08038 Regional Administrator, Region I Ms. Christina L. Perino U.S. Nuclear Regulatory Commission Director - Regulatory Assurance 475 Allendale Road PSEG Nuclear - N21 King of Prussia, PA 19406 P.O. Box 236 Hancocks Bridge, NJ 08038 Senior Resident Inspector Hope Creek Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038
ML051790057 OFFICE PDI-2/PE PDI-2/PM PDI-2/LA SRXB-A PDI-2/SC NAME GMiller SBailey CRaynor FAkstulwicz DRoberts DATE 6/29/05 7/12/05 6/29/05 7/5/05 7/14/05