ML051750707

From kanterella
Jump to navigation Jump to search
To Maine Yankee Final Status Survey Release Record FR-0200 Yard East Survey Unit 7
ML051750707
Person / Time
Site: Maine Yankee
Issue date: 06/20/2005
From: Olsen C
Maine Yankee Atomic Power Co
To:
NRC/FSME
References
FR-0200-07, Rev 0
Download: ML051750707 (21)


Text

MAINE YANKEE FINAL STATUS SURVEY RELEASE RECORD FR-0200 YARD EAST SURVEY UNIT 7 Prepared By:

Date: 40.Vune, Fengfn ignature Printed Name Reviewed By:

Date: 6 to/oE FSS SlN

,ture

_ r~iatlame Reviewed By:

L Date: IJUN 20 2005!

Independent Review - Signature Printed Name Approved By:

Date:

ern FSS, MOP - Signature 4cx

?- - 9.

Printed Name Revision 0

MAINE YANKEE FINAL STATUS SURVEY RELEASE RECORD FR-0200 YARD EAST SURVEY UNIT 7 A. SURVEY UNIT DESCRIPTION FR-0200 Yard East Survey Unit 7 was located in the NE corner of the former industrial area, mostly residing in the footprint of the Administration Building (FB-1200). The 1890 m2 area was bordered on the north and east by FR-2900 Survey Unit 2 (South Access Road and Lot C), on the wvest by FR-0200 Survey Unit 6, and on the south by FR-0200 Survey Unit 8. As shown on map FRO200-7 SITE, this survey unit is approximately centered by the coordinates 624,245E and 407,760N using the Maine State Coordinate System (West Zone) NAD 1927.

The location of the survey unit in relation to the Service Building and the surrounding FR-0200 and FR-0 11 survey units is shown on map FRO200-7 REF (Attachment I). The survey unit is located within the expanded Restricted Area boundary.

Survey Unit 7 is an area composed primarily of soil and backfill. As shown on map FR0200-7c, the survey unit is relatively flat with several trenches due to remediation activities, including storm drain and sewer line removal.

B. SURVEY UNIT DESIGN INFORMATION Survey Unit 7 was originally classified per the LTP Revision 4 as a Class 3 survey unit, but was reclassified to Class 1 given its history during decommissioning activities.

The survey unit design parameters are shown in Table I. Given a relative shift of 1.5, eighteen direct measurements would be required for the Sign Test, but 40 were prescribed as a conservative measure. Because the measurement locations were based on a systematic square grid with a random start point, the N=40 design led to a survey unit map with 42 locations which are illustrated on map FRO200-7b (Attachment 1). Direct measurements (soil samples) were collected from required locations and analyzed with laboratory gamma spectroscopy instrumentation.

In accordance with the LTP, scans covering 100% of the 1890 m2 area were required for the Class I survey unit. This was accomplished by use of an in situ gamma spectroscopy detector (ISOCS) configured at a 3-meter distance from the surface to obtain overlapping 28-m2 fields of view for the 108 shots. The ISOCS detector was positioned perpendicular to the surface. Locations of the 108 survey scans are shown on maps FRO200-7a and 7c (Attachment 1).

The ISOCS scans were configured to ensure 100% scan coverage of all exposed surfaces within Survey Unit 7. The survey instruments used are listed by model and serial number in (Table 2-1). Scan MDCs are also listed in Attachment 2 (Table 2-2) and are compared to the DCGL, the investigation level, and the DCGLEMC. The scan MDC is less than the scan investigation level, thus providing high confidence (95% or higher) that an elevated area would be detected in the scanning process. Furthermore, since the investigation level was always less than the design DCGLE1%C, no EMC sample size adjustment was necessary.

FR-0200-07, Revision 0 Page 2 of 21

TABLE I SURVEY UNIT DESIGN PARAMETERS Survey Unit Design Criteria Basis Area 1890 m2 Class 1, < 2,000 m2 Based on an LBGR of 2.1 Number of Direct pCi/g, sigma' of 1.33 pCi/g Measurements Required 18 (40 used for design) and a relative shift of 1.5, 18 were required, 42 obtained.

Type I = Type II = 0.05 Sample Area 47 m2 1890 M2 /40 = 47 m2 Sample Grid Spacing 6.8 m (47)12 Scan Grid Area ISOCS scan at 3 meters See Section B Area Factor 1.5 Class 1 Area, LTP Table 6-12 Scan Area 1890 m2 Class I Area - 100%

Level 1.0 pCi/g Cs-137 ISOCS investigation levels Scan0.36 pCi/g Co-60 (Reference 3) 4.2 pCi/g Cs-137 DCGL applied to land outside DCGL152 pCi/g Co-60 the Restricted Area 1.52 ~i/g o-60(Reference I) 6.4 pCi/g Cs-] 3 7 DCGL x Area Factor for Design DCGLEMC 263 pCi/g Co-60 Class I survey unit, per LTP 2.3 pi/g o-60Section 5.6.3 C. SURVEY RESULTS A total of 42 direct measurements were performed in Survey Unit 7. Six samples contained detectable Cs-137 with levels of activity greater than the MDA but below the DCGL. Three samples contained detectable Co-60 activity above the MDA but below the DCGL. All other measurements were below the MDA. The results are presented in Table 2. No investigations were necessary as a result of the direct measurements.

ISOCS gamma scans were performed at 108 locations using an investigation level of 1.0 pCi/g Cs-l 37 and 0.36 pCi/g Co-60. The gamma scans were performed for a sufficient count time to achieve a Minimum Detectable Activity (MDA) of approximately 16% of the DCGL.

All identified scan activity levels and MDAs were below the investigation levels. Therefore, no investigation surveys were performed as a result of the scan surveys.

LTP Revision 4, Table 5-IC for RCA Yard West, ROI00 (conservative).

FR-0200-07, Revision 0 Page 3 of 21

TABLE 2 DIRECT MEASUREMENTS Sample Number Cs-I 37 Uncertainty Co-60 Uncertainty Unitized Value (pCilg)

(pCi/g)

(pCi/g)

(pCi/g)

FRO200071SOO1

< 6.57E-02 6.00E-02 l

5.51E-02 FR0200071S002

< 3.93E-02_

4.70E-02 4.03E-02 FR0200071S003

< 4.61E-02 5.1 1E-02 4.46E-02 FR0200071S004

< 5.85E-02 7.41E-02 6.27E-02 FR0200071S005

< 4.08E-02 4.42E-02 3.88E-02 FRO200071SO06

< 5.60E-02 5.93E-02 5.23E-02 FRO20007IS007

< 4.25E-02 4.13E-02 3.73E-02 FR0200071S008

< 5.16E-02 5.37E-02 4.76E-02 FR0200071SO09

< 4.64E-02 5.07E-02 4.44E-02 FRO200071SO10

< 4.57E-02 5.18E-02 4.50E-02 FR0200071SOIl

< 4.29E-02 4.64E-02 4.07E-02 FR0200071S012 9.40E-02 3.27E-02 5.63E-02 5.94E-02 FR0200071S013

< 4.35E-02 5.75E-02 4.82E-02 FR0200071S014 8.56E-02 3.08E-02 7.56E-02 7.01E-02 FR0200071S015

< 4.26E-02 4.74E-02 4.13E-02 FR0200071S016

< 4.68E-02 5.01E-02 4.41E-02 FR0200071S017

< 4.50E-02 5.25E-02 4.53E-02 FR0200071S018 9.62E-02 2.58E-02 6.36E-02 6.47E-02 FR0200071SO19

< 4.71E-02 5.65E-02 4.84E-02 FR0200071S020 9.75E-02 2.99E-02 _

1.34E-01 3.35E-02 1.1IE-O1 FR0200071S021

< 5.82E-02 5.71E-02 5.14E-02 FR0200071S022

< 4.46E-02 4.84E-02 4.25E-02 FR0200071S023

< 4.35E-02 5.20E-02 4.46E-02 FR0200071S024

< 4.86E-02 5.78E-02 4.96E-02 FR0200071S025

< 5.97E-02 6.12E-02 5.45E-02 FR0200071S026

< 4.62E-02 4.50E-02 4.06E-02 FR0200071S027

< 4.77E-02 5.53E-02 4.77E-02 FR0200071S028

< 4.1OE-02 3.93E-02 3.56E-02 FR0200071S029

< 6.21E-02 6.80E-02 5.95E-02 FR0200071S030 1.06E-01 3.45E-02 2.20E-01 3.44E-02 1.70E-OI FR0200071S031 2.29E-01 4.23E-02

= 4.OOE-01 4.08E-02 3.18E-O1 FR0200071S032

< 4.08E-02 5.29E-02 4.45E-02 FR0200071S033

< 4.70E-02 5.09E-02 4.47E-02 FR0200071S034

< 3.96E-02 4.32E-02 3.78E-02 FR0200071S035

< 4.74E-02 5.26E-02 4.59E-02 FR0200071S036

< 4.47E-02 4.45E-02 3.99E-02 FR0200071S037

< 6.77E-02 6.44E-02 5.85E-02 FR0200071S038

< 4.49E-02 4.99E-02 4.35E-02 FR0200071S039

< 4.05E-02 4.55E-02 3.96E-02 FR0200071S040

< 5.00E-02 5.77E-02 4.99E-02 FR0200071S041

< 4.44E-02 4.57E-02 4.06E-02 FR0200071S042

< 4.81E-02 5.65E-02 4.86E-02 Mean 5.80E-02 6.76E-02 5.83E-02 Median 4.69E-02 5.28E-02 4.56E-02 Standard Deviation 3.21 E-02 6.02E-02 4.68E-02 Range 3.93E-02 to 2.29E-01 3.93E-02 to 4.OOE-01 3.56E-02 to 3.1813-01

"<" indicates MDA value. Bold indicates positive detection value FR-0200-07, Revision 0 Page 4 of 21

D. SURVEY UNIT INVESTIGATIONS PERFORMED AND RESULTS Based on the scan results, no investigations were required.

E. SURVEY UNIT DATA ASSESSMENT An analysis of the direct sample measurement results, including the mean, median, standard deviation and sample result range, is provided in Table 2. Positively detected values are bolded in the table. Of the 42 soil samples collected, six identified Cs-137 activity below the DCGL value of 4.2 pCi/g and three samples identified Co-60 activity below the DCGL value of 1.52 pCi/g. All other values were below the MDA. Identified sample activities or Minimum Detectable Activities are listed in Table 2. The mean and median activities were less than the DCGLs for Cs-137 and Co-60. The average of the unity measurements was 0.058 indicating that the direct measurements averaged 5.8% of the DCGL limit.

For illustrative purposes, as indicated in LTP Section 5.9.3, a simplified general retrospective dose estimate can be calculated from the average residual contamination level by subtracting the mean fallout Cs-137 value (0.19 pCi/g)2 for disturbed soil from the survey unit sample mean activity (0.058 pCi/g). This would equate to an annual dose rate of 0.0 mrem/year.

Taking into account the average residual contamination for Co-60, the annual dose rate would equate to 0.45 mrenyrn

. Also, for purposes of demonstrating compliance with the radiological criteria for license termination and the enhanced State of Maine criteria, background activity was not subtracted from the sample analysis activity values.

F. ADDITIONAL DATA EVALUATION provides additional data evaluation associated with this Survey Unit, including relevant statistical information. Based on survey unit direct measurement data, this attachment provides the Sign Test Summary, Quantile Plot, Histogram, and Retrospective Power Curve.

1. The Sign Test Summary provides an overall summary of design input (Table 1) and resulting calculated values used to determine the required number (N) of direct measurements (per LTP Section 5.4.2). The Sign Test Summary is a separate statistical analysis that also calculates the mean, median, and standard deviation of the direct measurements.

The critical value and the result of the Sign Test are provided in the Sign Test Summary table, as well as a listing of the key release criteria. The direct measurements clearly pass the Sign Test. The subject release criteria have been satisfied. In addition, the sample standard deviation is smaller than the design sigma; therefore, no additional samples were required.

2 See Attachment E to Maine Yankee Procedure PMP 6.7.8 (Reference 2).

3 This annual dose is based on LTP Section 6.7, which shows the contaminated soil contribution (for soils contaminated at the DCGL) to be 10 mremly. Therefore, the annual Co-60 dose rate (using the Co-60 DCGL of 1.52 pCi/g outside the RA and the mean Co-60 direct activity value of 0.068 pCi/g) would equate (0.068' to Annual Dose Rate =0 lx 1.)

= 0.45 mrem /ly.

FR-0200-07, Revision 0 Page 5 of 21

2. The Quantile Plot was generated from the unity data listed in Table 2. The data set and plot are consistent with expectations for a Class I survey unit. All of the measurements are below the DCGLs of 4.2 pCi/g (Cs-I 37) and 1.52 pCi/g (Co-60) for land outside the restricted area.
3. A Histogram Plot was also developed. This plot shows a log-normal distribution with one outlier.
4. A Retrospective Power Curve was constructed, based on FSS results. The curve shows that this survey unit having a mean residual activity at a small fraction of the DCGL has a high probability ("power") of meeting the release criteria. Thus, it can be concluded that the direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.

G. CHANGES IN INITIAL SURVEY UNIT ASSUMPTIONS ON EXTENT OF RESIDUAL ACTIVITY The survey was designed as a Class I land survey area; the FSS results were consistent with that classification. The direct measurement sample standard deviation was less than the design sigma. Thus, a sufficient number of sample measurements were taken and no additional measurements were required.

HS. LTP CHANGES SUBSEQUENT TO SURVEY UNIT FSS The FSS of Survey Unit 7 was designed, performed, and evaluated in the June 2005 time frame. The design was performed to the criteria of the LTP Revision 4 (Reference 1). No subsequent LTP changes with potential impact to this survey unit need to be evaluated.

1. CONCLUSION The FSS of this survey unit was designed based on the designation as a Class I area. The survey design parameters are presented in Table 1. The required number of direct measurements was determined for the Sign Test in accordance with the LTP. As presented in Table 2, all direct measurements were less than the DCGLs of 4.2 pCi/g Cs-137 and 1.52 pCilg Co-60. There were no investigations.

A Sign Test Summary analysis demonstrated that the Sign Test criteria were satisfied. The direct measurement sigma was determined to be less than that used for design, thus indicating that a sufficient number of samples was taken.

The Retrospective Power Curve shown in Attachment 4 confirmed that sufficient samples were taken to support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and the data quality objectives were met. Attachment 4 also revealed that direct measurement data represented essentially a log-normal distribution with one outlier.

FR-0200-07, Revision 0 Page 6 of 21

The scan survey design for this survey unit was developed in accordance with the LTP Revision 4 (Reference 1) with significant aspects of the design discussed in Section B and Table 1. ISOCS scans performed in a systematic grid pattern throughout the survey unit did not identify activity above the scan investigation levels of 1.0 pCi/g Cs-137 and 0.36 pCi/g Co-60. Therefore, no investigations were required as a result of the scan process.

It is concluded that FR-0200 Survey Unit 7 meets the release criteria of IOCFR20.1402 and the State of Maine enhanced criteria.

J. REFERENCES

1. Maine Yankee License Termination Plan, Revision 4, February 28, 2005 provided by Maine Yankee letter to the NRC, MN-05-010
2. Maine Yankee Procedure PMP 6.7.8, FSS Data Processing and Reporting, Attachment E, Approach for Dealing With Background Radioactivity for Maine Yankee Final Status Surveys
3. Maine Yankee Calculation No. EC-003-04, Use of Canberra In Situ Object Counting System (ISOCS) for FSS Surveys FR-0200-07, Revision 0 Page 7 of 21 Survey Unit Maps FR-0200-07, Revision 0 Page 8 of 21

I) 0 00 o

Al 0

0

'1 i

0CO 0

0 0

0 co 0

0 40

%D 0

0 b,

0 0

0 Al 0

0 0

6 LA 0

0 00 0

A 0

0 10 go 0

tl

-TJ rA 0

0

_ 623.000 E 623. 500 E

-624,000 C

-624,500 E

Q 3 625,000 C

- 625, 500 E

_ 626, 000 E Note: Grid based on Maine State Coordinate System (West Zone) NAD 1927 cn C

CO

--4 l0 CO CD 0

0:)a)

M CO a

R P) 0

-4 c

0 CO tD U

215.

a)

Ln (I)

CCO

2 C

(3 0) a)

M W

m tn CD 0

2 g.

nCD o CD CD 3

0 CD

-n a.

-a.

a--.

KO)

Cl)

CD, cn rn M

FRO200 SU7

Maine Yankee I

Map ID #: FRO200-7 REF Decommissioning Team Maine Yankee Decommissioing Project Survey ForI Date: 6/9/05 Survey Type:

E Characterization O Turnover D Final Status Survey l Survey Area Name: Yard East Final Status Survey FRO200 SU7 Reference Map f ---

FR-0200-07, Revision 0 Page IO of 21 FRO200 SU7 Total Survey Unit Area = 1890 sq-m

Maine Yan~e fieYnkee eoizsinn rjc uvyFrnMap ID #: FRO200-7a Decommissioning Team Maie IanIkee Decommissioning Project Surve Forii: Date: 6/20105 Survey Type:

El Characterization C] Turnover X Final Status Survey Survey Area Name: RCA Yard East Soils Final Status Survey FRO200 SU7: RCA Yard East Soils ISOCS Scans S001 - S093 Start FR-0200-07, Revision 0 Page II of 21

Maine Yankee Map ID #: FRO200-7b Decommissioning Team I Mlaine Yanikee Decommissioning Project Surv'ey Form IDate: 6/20105 Survey Type:

0 Characterization i Turnover R-Final Status Survey I Survey Area Name: RCA Yard East Soils Final Status Survey FRO200 SU7: RCA Yard East Soils Direct Points SOO1 - S042 624,318.1 E 407,774.5N 624,294.3 E 407,661.9 N Surface Area = 1890 sq-m N=40 L=6.8m FR-0200-07, Revision 0

  • Page 12 of 21

Maine Yankee

.1nn I Map ID #: FRO200-7c Decommissioning Team Maine Yankee Decomnniissioning Project Survy For Date: 6/15/05 Survey Type:

El Characterization E Turnover J Final Status Survey Survey Area Name: RCA Yard East Soils Final Status Survey FRO200 SU7: RCA Yard East Soils ISOCS Trench Scans S094 - S108 FR-0200-07, Revision 0 Page 13 of 21 Survey Unit Instrumentation FR-0200-07, Revision 0 Page 14 of 21

TABLE 2-I INSTRUMENT INFORMATION ISOCS Dctectors (Field Measurements)

Detector No.

MDC (pCi/g) 7605 0.17 to 0.33 7607 0.12 to 0.33 7722 0.11 to 0.32 IHPGe Detectors (Laboratory Analysis)

Detector No.

MDC (pCi/g)

FSS I 0.04 to 0.08 FSS2 0.03 to 0.06 TABLE 2-2 INSTRUMENT SCAN MDC, DCGL, INVESTIGATION LEVEL AND DCGLE51C Parameter Instrument: ISOCS Comments Scan MDC 0.20 to 0.33 pCi/g Cs-] 37 16% DCGL 0.1I1 to_0.24_pCilg Co-60 4.2 pCi/g Cs-I 37 Approved DCGL for land DCGL 1.52 pCi/g Co-60 areas outside the Restricted 1.52 ~ilg o-60 Area (Reference 1)

Investigation Level 1.0 pCi/g Cs-137 (ISOCS @ 3 m) 0.36 pCi/g Co-60 (Reference 3) 6.4 pCi/g Cs-137 DCGL x Area Factor for Design DCGLEMC 2.3 pCi/g Co-60 Class I survey unit, per 2.3 pifg o-60 LTP Section 5.6.3 FR-0200-07, Revision 0 Page 15 of 21 Investigation Table (No Investigations Required)

FR-0200-07, Revision 0 Page 16 of 21 Statistical Data FR-0200-07, Revision 0 Page 17 of 21

Survey Package FRO200 Unit 7 UNITY Soil Sign Test Summary

<f,-',<};~Et'af itior npstViis~+!;'8ta5'rN CCo-rnmen sf!'4it~

Survey Package:

FRO200 Survey Unit:

07 Evaluator:

Andy Olsen DCGLw:

1.OOE+O0 Unity DCGLmc:

1.50E+00 AF = 1.5 LBGR:

5.OOE-01 Sigma:

3.17E-01 (1.33 pCilg /4.2 pCi/g)

Type I error:

.0 5 Type II error:

0.05 Nuclide:

UNITY Soil Type:

N/A Z,

~

A1'.645

,-:1.645 Sign p:

0.933193 Calculated Relative Shift:

5 Relative Shift Used 1 5 Uses 3.0 if Relative Shift is >3 N-Value:

15 N-Value+20%:

.18

-P~~-'t'+.r>&X~,=S-,Sairne Damrnalen iA.-^Ad~tst!.

Number of Samples r.

',42 Median :

4.56E-O2 Mean:

A

, 5t 83E-02 Net Sample Standard Deviation:

4.68E-02 Total Standard Deviation:

4

,.,.68

'02 Sum of samples and reference Maximum:

'&,318E-01 i

g nBeru Tet'esult;s'7

->/S,-<C

met, sn,,i lt2<-

Adjusted N Value: z>

42 S+ Value:.,42,-.-,,

';_-__;42 Critical Value;,

26 Sign test results:

-Pass Sufficient samples collected: it -

f

,. ' ass Maximum value <DCGLW.

Pas Median value <DCGLW',:

-Pjass Mean value <DCGLW,:

-pass Maximum value <DCGL,Pcass Total Standard Deviation <=Sigma:.

.- Pass Criteria comparison results: -,-.'? ~iPa-ss`

c o nd7ition!C Oats i

The survey unit passes all conditions ntE e'aPass Survey Unit Passes FRO200-SU7-Soi1Sign-UN1TY.xls 6118105 6:10 PM FR-0200-07, Revision 0 Page 18 of 21

FRO200 SU-7 Quantile Plot 0.35 0

-0

w.

(D t'J ?

0 C N

'I-I UNE 0

0.3 0.25 0.2 0.15 0.1 0.05 4

-I-!--._

  • Activity (unitized)

Median (unitized) 0 0

25 50 75 100 Percent

One-Sample T-Test Report Page/Date/Time 2

6/20/05 5:12:07 AM Database Variable C2 Plots Section Histogram of FR-0200, SU-7 40

.f 30 E

C,,

a)

Z 20

-D E

3 10
., I 4",.,

, t_ __

0.000 0.088 0.175 0.253 Activity (unitized) 0.350 FR-0200-07, Revision 0 Page 20 of 21

One-Sample T-Test Power Analysis Page/Date/Time 2 6/20/05 5:13:25 AM Chart Section 0-0o Retrospective Power Curve 1.0-0.8 0.6-0.4, 0.2-.,

F 0.0*

I t

0.0 0.2 0.4 0.6 0.8 1.0 Survey Unit Mean (unitized)

FR-0200-07, Revision 0 Page 21 of 21