Ck NMC Committed to NudearExcell' Kewaunee Nuclear Power Plant Operated by Nuclear Management Company, LLC April 26, 2005 NRC-05-047 10 CFR 50.36a(a)(2)
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Kewaunee Nuclear Power Plant Docket 50-305 License No. DPR-43 Radioactive Effluent Release Report Januarv - December 2004 Enclosed please find a copy of the Kewaunee Nuclear Power Plant Radioactive Effluent Release Report for January through December 2004. This report is submitted to meet the requirements of Technical Specification 6.9.b.2 and 10 CFR 50.36a(a)(2).
Craig W. La ert Site Vice President, Kewaunee Nuclear Power Plant Nuclear Management Company, LLC Enclosure cc:
Administrator, Region ll, USNRC Project Manager, Kewaunee, USNRC Resident Inspector, Kewaunee, USNRC I (E7q ?)
N490 Highway 42
- Kewaunee, Wisconsin 54216-9511 Telephone: 920.388.2560
ENCLOSURE I KEWAUNEE NUCLEAR POWER PLANT RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2004
KEWAUNEE NUCLEAR POWER PLANT RADIOACTIVE EFFLUENT RELEASE REPORT January -,De-cember,2004 NUCLEAR MANAGEMENT COMPANY, LLC
DOCKET 50-305 KEWAUNEE NUCLEAR POWER PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 1 - December 31, 2004 Nuclear Management Company, LLC April 12, 2005
Table of Contents Section Description 0.0 Summary.............................................
3 1.0 Introduction.............................................
3 1.1 Effluent Dose.............................................
3 2.0 Gaseous Effluents.............................................
4 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents.................................. 4 2.2 Gaseous Batch Release Statistics.............................................
6 2.3 Gaseous Effluent Data.........................................
- .6 Table 2.1 Gaseous Effluents - Summation of all Releases............................... 7 Table 2.2 Gaseous Effluents - Elevated Releases........................................
8 Table 2.3A Gaseous Release Total.......................................
10 Table 2.3B Gaseous Release Continuous.......................................
18 Table 2.3C Gaseous Release Batch.......................................
26 Table 2.4 Dose From Gaseous Effluents.......................................
34 3.0 Liquid.Effluents.......................................
36 3.1 Lower Limits of Detection (LLD) for Liquid Effluents................................... 36 3.2 Liquid Batch Release Statistics........................................
38 3.3 Liquid Effluent Data.......................................
38 Table 3.1 Liquid Effluents - Summation of all Releases.39 Table 3.2A Liquid Effluents - Batch Releases 1st Quarter.40 Table 3.2B Liquid Effluents -Batch Releases 2nd Quarter.42 Table 3.2C Liquid Effluents -Batch Releases 3rd Quarter.44 Table 3.2D Liquid Effluents - Batch Releases 4th Quarter.46 Table 3.3A Liquid Effluents - Continuous Releases 1st Quarter
.48 Table 3.3B Liquid Effluents - Continuous Releases 2nd Quarter.50 Table 3.3C Liquid Effluents - Continuous Releases 3rd Quarter.52 Table 3.3D Liquid Effluents - Continuous Releases 4th Quarter.54 Table 3.4 Dose From Liquid Effluents....................................
56 4.0 Unplanned Releases........................................58 5.0 Meteorological Data.58 6.0 Solid Waste Disposal......................................58 Table 6.1 Solid Waste and Irradiated Fuel Shipments.59 7.0 Program Revisions......................................62 8.0 Reportable Occurrences.62 Appendix A.
Meteorological Data Page 2 of 62
0.0
SUMMARY
During 2004 all solid, liquid, and gaseous radioactive effluents from the Kewaunee Nuclear Plant were well below regulatory limits. For individual effluent streams, the quarterly limit most closely approached was:
GASEOUS:
Ingestion Pathway-Organ Liver Quarterly Limit (mRems) 7.5 Actual Dose (mRems) 0.0003632 (4th Quarter)
% of Specification 0.004843 LIOUID:
Ingestion Pathway-Organ GI-LLI Quarterly Limit (mnRems) 5 Actual Dose (mnRems) 0.004948 (4th Quarter)
% of Limit 0.10 SOLID:
No upper limit for solid radioactive waste applies.
Cubic Meters Shipped 146.2 m3 (5162 f1W)
1.0 INTRODUCTION
This report is being submitted in accordance with the requirements of Kewaunee Technical Specifications, Section 6.9.b.2 and the Offsite Dose Calculation Manual, Section 3/4.7. It includes data from all effluent releases made from January 1 -December 31, 2004. The report contains summaries of the gaseous and liquid releases made to the environment including the quantity, characterization, time duration and calculated radiation dose at the site boundary resulting from these releases. The report also includes a summation of solid waste disposal, revisions to the Process Control Program and the Offsite Dose Calculation Manual, and addresses the cumulative meteorological data. Values indicated as 0 (zero) in this report refer to actual values less than the detection limits. A table of these less than (LID) values is identified in sections 2.1 and 3.1.
1.1 Effluent Dose Limits Specifications are set to ensure that offsite doses are maintained as low as reasonably achievable while still allowing for practical and dependable operation of the Kewaunee Plant.
The Kewaunee Offsite Dose Calculation Manual (ODCM) describes the methodology and parameters used in:
1.)
The calculation of radioactive liquid and gaseous effluent monitoring instrumentation alarm/trip setpoints.
2.)
The calculation of radioactive liquid and gaseous concentrations, dose rates and cumulative quarterly and annual doses. The ODCM methodology is acceptable for use in demonstrating compliance with 10 CFR 20.106; 10 CFR 50, Appendix I; and 40 CFR 190.
Page 3 of 62
2.0 GASEOUS EFFLUENTS 2.1 Lower Limits of Detection (LLD) for Gaseous Effluents Gaseous radioactive effluents are released in both the continuous mode and the batch mode. The auxiliary building stack is sampled continuously for particulates, halogens and Strontium by an "off-line" sample train. This stack is also grab-sampled daily for gaseous gamma emitters. Batch releases are sampled prior to release for principal gaseous and particulate gamma emitters, halogens and tritium.
The LLD's for gaseous radioanalyses, as listed in Table 4.4 of the Kewaunee ODCM are:
Analysis LLD (tiCi/ml)
Gaseous Gamma Emitters Iodine 131 Particulate Gamma Emitters Particulate Gross Alpha Strontium 89, 90 Noble Gases, Gross Beta or Gamma 1.00 E-04 3.00 E-12 1.00 E-1 I 1.00 E-l l 1.00 E-l1 1.00 E-06 The nominal "a priori" LLD values are shown below.
Isotope a priori LLD ([tCi/ml)
- a. Gaseous emissions:
Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Xe-138 5.611E-08 1.02E-07 6.68E-08 2.75E-07 2.99E-08 1.13E-07 Page 4 of 62
- b. Particulate emissions:
Mn-54 1.1lE-1:
Fe-59 2.27E-1:
Co-58 2.28E-1:
Co-60 3.57E-1:
Zn-65 1.68E-1' M6-99 2.73E-1:
Cs-134 4.69E-1:
Cs-137 1.68E-1' Ce-141 2.08E-1' Ce-144 1.24E-1'
- c. Other identifiable gamma emitters:
3 3
3 3
3 3
3 3
3 2
Ar-41 Kr-85 Kr-85m Kr-89 Xe-127 Xe-131m Xe-135m Xe-137 1131 3.97E-10 8.63E-05 4.62E-08 2.04E-06 4.20E-08 1.82E-06 1.90E-08 2.88E-07 1.32E-13
- d. Composite particulate samples:
Sr-89 1 E-14 Sr-90 '
1 E-14 Gross Alpha 1.00 E-14 These "a priori" LLDs represent the capabilities of the counting systems in use, not an after the fact "a posteriori" limit for a particular measurement.
Page 5 of 62
L L
L L
L L
2.2 Gaseous Batch Release Statistics The following is a summation of all gaseous batch releases made during 2004.
Number of batch releases...........................
48 Total time for all batch releases (min)........... 20114.0 Maximum time for a batch release (min)......... 2623.0 Average time for a batch release (min).............. 419.0 Minimum time for a batch release (min)............... 7.0 2.3 Gaseous Effluent Data The following table 2.1 presents a quarterly summation of the total activity released and average release rates of four categories of gaseous effluents. Table 2.2 lists the quarterly sums of individual gaseous radionuclides released by continuous and batch modes. Table 2.3 is essentially the same data, but is presented as monthly summations. Table 2.4 presents the dose limits for gaseous effluents, and the calculated doses this year from gaseous effluents.
Page 6 of 62
Table 2.1 Annual Radioactive Effluent Release Report 2004 Gaseous Effluents - Summation of all Releases Fission and Activation Gases 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Total Activity Released (Ci)
Average Release Rate (IiCi/sec) 5.424E-003 6.899E-004 1.960E-003 2.492E-004 4.583E-003 5.830E3-004 8.538E-002 1.086E-002 Iodines Total Activity Released (Ci)
Average Release Rate (p.Ci/sec) 0.OOOE+000 0.OOOE3+000 0.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 Particulates Total Activity Released (Ci)
Average Release Rate (gCi/sec) 0.OOOE+000 0.OOOE+006 O.OOOE+000 O.OOOE+000 0.OOOE3+O00 0.OOOE+000 0.OOOE+000 0.OOOE+O000 Gross Alpha Released (Ci)
O.OOOE+000 0.OOOE+000 O.OOOE+000 0.OOOE+000 Tritium Total Activity Released (Ci)
Average Release Rate (ipCi/sec) 2.379E+000 3.0251E-001 7.132E-001 9.0711E-002 1.1 13E+000 1.416E-001 1.719E+001 2.187E+000 Page 7 of 62
Table 2.2 Annual Radioactive Effluent Release Report 2004 Gaseous Effluents Nuclides Released (Ci)
Continuous Mode iarter 2nd Quarter 3rd Quarter 4th 1st Qu Quarter Fission Gases Total lodines Total Particulates Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000
)
L L
L Page 8 of 62
Table 2.2(cont)
Annual Radioactive Effluent Release Report 2004 Gaseous Effluents Nuclides Released (Ci)
Batch Mode Fission Gases Ar-41 Kr-85m Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Total 2.192E-003 O.OOOE+000 O.OOOE+000 O.OOOE+000 3.2199E-003 O.OOOE+000 1.308E-005 5.424E-003 O.OOOE+000 0.000E+000 0.OOOE+000 O.OOOE+000 O.OOOE+000 1.956E-003 0.OOOE+000 3.472E-006 1.960E-003 0.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 4.55 1E-003 O.OOOE+000 3.270E-005 4.583E-003 O.OOOE+000 5.538E-003 6.376E-004 2.254E-004 9.4188E-004 7.412E-002 6.649E-004 3.256E-003 8.538E-002 0.0OOOE+000 Iodines Total Particulates Total 0.OOOE+000 0.000E3+000 0.OOOE+000 O.OOOE+000 Page 9 of 62
Table 2.3A Annual Radioactive Effluent Release Report 2004 1st Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope January February March Total Ar-41 Xe-133 Xe-135 Total 2.192E-003 1.480E-003 0.OOOE+000 3.673E-003 0.OOOE+000 0.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 1.739E-003 1.308E-005 1.752E-003 2.192E-003 3.219E-003 1.308E-005 5.424E-003 Particulates (Curies)
I Isotope January February March Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope January February March Total Total 0.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 Page 10 of 62
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2004 1st Quarter Gaseous Release Total of all Releases Summary January February March Total Total Noble Gases (Ci)
Total Halogens (Ci) 3.673E-003 O.OOOE+000 O.OOOE+000 O.OOOE+000 1.752E-003 O.OOOE+000 5.424E-003 O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci)
O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Total Tritium (Ci) 1.534E+000 8.372E-001 7.164E-003 2.379E+000 Total Particulate Gross Alpha (Ci) 0.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 11 of 62
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2004 2nd Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope April May June Total Xe-133 Xe-135 Total 2.479E-004 O.OOOE+000 2.479E-004 3.627E-004 3.472E-006 3.662E-004 1.346E-003 0.OOOE+000 1.346E-003 1.956E-003 3.472E-006 1.960E-003 Particulates (Curies)
Isotope April May June Total Total 0.001OE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 Halogens (Curies)
Isotope April May June Total Total O.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 Page 12 of 62
Table 2.3A (Con't)
Annual Radioactive Effluent Release-Report 2004 2nd Quarter Gaseous Release Total of all Releases Summary April May June Total Total Noble Gases (Ci) 2.479E-004 Total Halogens (Ci) 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci)
O.OOOE+000 Total Tritium (Ci) 4.341E-001 Total Particulate Gross Alpha (Ci) 0.OOOE+000 3.662E-004 0.OOOE+000 O.OOOE+000 2.741E-001 0.OOOE+000 1.346E-003 O.OOOE+000 0.OOOE+000 4.976E-003 O.OOOE+000 1.960E-003 O.OOOE+000 0.OOOE+000 7.132E-001 0.01OOE+000 Page 13 of 62
Table 2.3A (con't)
Annual Radioactive Effluent Release Report 2004 3rd Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope July August September Total Xe-133 Xe-135 Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 4.551E-003 3.270E-005 4.583E-003 4.551E-003 3.270E-005 4.583E-003 Particulates (Curies)
Isotope July August September Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Halogens (Curies)
Isotope July August September Total Total.
O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 14 of 62
Ii IL i
iL L
L_.
iL II_
I 1
I i
t iL 1
7 L_
I I
I Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2004 3rd Quarter Gaseous Release Total of all Releases August September Tc Summary July otal Total Noble Gases (Ci)
O.OOOE+000 Total Halogens (Ci)
O.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci)
O.OOOE+000 Total Tritium (Ci) 5.882E-001 Total Particulate Gross Alpha (Ci)
O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 4.583E-003 O.OOOE+000 O.OOOE+000 5.251E-001 O.OOOE+000 4.583E-003 O.OOOE+000 O.OOOE+000 1.113E+000 O.OOOE+000 Page 15 of 62
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2004 4th Quarter Gaseous Release Total of all Releases Noble Gasses (Curies)
Isotope October November December Total Ar-41 Kr-85m Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Total 5.538E-003 6.376E-004 2.254E-004 9.418E-004 7.4122E-002 6.649E-004 3.256E-003 8.538E-002 0.OOOE+000 0.OOOE3+000-O.OOOE3+000 0.OOOE+000 0.OOOE3+000 0.OOOE+000 0.OOOE3+000 0.OOOE3+000 0.OOOE3+000 0.0 OOE+000 0.OOOE3+000 0.00013+000 0.OOOE3+000 0.OOOE3+000 0.00 OE+000 0.OOOE3+000 5.538E-003 6.376E-004 2.254E-004 9.4188E-004 7.4122E-002 6.649E-004 3.256E-003 8.538E-002 Particulates (Curies)
Isotope October November December Total Total 0.000E+000 0.OOOE3+000 0.OOOE+000 0.OOOE1+000 Halogens (Curies)
Isotope October November December Total Total 0.OOOE3+000 0.000E+000 0.000E+000 0.000E+000 Page 16 of 62
Table 2.3A (Con't)
Annual Radioactive Effluent Release Report 2004 4th Quarter Gaseous Release Total of all Releases Summary October November December Total Total Noble Gases (Ci) 8.538E-002 Total Halogens (Ci) 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+000 Total Tritium (Ci) 6.432E-001 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.000E+000 0.000E+000 0.OOOE+000 1.563E+001 0.OOOE+000 0.OOOE+000 0.000E+000 0.OOOE+000 9.180E-001 0.OOOE+000 8.538E-002 0.OOOE+000 0.OOOE+000 1.719E+001 0.OOOE+000 Page 17 of 62
Table 2.3B Annual Radioactive Effluent Release Report 2004 1st Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)
Isotope Total January 0.000E+000 February 0.OOOE+000 March 0.000E+000 Total 0.000E+000 Particulates (Curies)
Isotope January Total 0.000E+000 Halogens (Curies)
Isotope January Total 0.000E+000 February 0.000E+000 February 0.000E+000 March 0.000E+000 March 0.000E+000 Total 0.000E+000 Total 0.000E+000 Page 18 of 62
L L
L L_.
K L
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2004 1st Quarter Gaseous Release Continuous Mode Only ary February March To Sunmmary Janu=
ital Total Noble Gases (Ci) 0.000E+000 Total Halogens (Ci) 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.000E+000 Total Tritium (Ci) 6.982E-001 Total Particulate Gross Alpha (Ci) 0.000E+000 0.000E+000 0.000E+000 0.OOOE+000 8.372E-001 0.000E+000 0.0 OE+000 0.OOOE+000 0.OOOE+000 4.969E-003 0.000E+000 0.000E+000 0.OOOE+000 0.000E+000 1.540E+000 0.000E+000 Page 19 of 62
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2004 2nd Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)
Isotope April Total 0.000E+000 May 0.000E+000 June 0.000E+000 Total 0.000E+000 Particulates (Curies)
Isotope April Total 0.000E+000 Halogens (Curies)
Isotope April Total 0.000E+000 May 0.000E+000 May 0.000E+000 June O.OOOE+000 June 0.OOOE+000 Total 0.000E+000 Total 0.OOOE+000 Page 20 of 62
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2004 2nd Quarter Gaseous Release Continuous Mode Only I
May June To Summary April ital Total Noble Gases (Ci) 0.000E+000 Total Halogens (Ci) 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.000E+000 Total Tritium (Ci) 4.341E-001 Total Particulate Gross Alpha (Ci) 0.000E+000 0.OOOE+000 0.000E+000 0.0 OE+000 2.741E-001 0.000E+000 0.OOOE+000 0.000E+000 0.OOOE+000 4.026E-003 0.000E+000 0.OOOE+000 0.OOOE+000 0.000E+000 7.122E-001 0.OOOE+000 Page 21 of 62
Table 2.3B (con't)
Annual Radioactive Effluent Release Report 2004 3rd Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)
Isotope July O.OOOE+000 August 0.OOOE+000 September 0.000E+000 Total 0.000E+000 Total Particulates (Curies)
Isotope Total July 0.000E+000 August 0.OOOE+000 September 0.000E+000 Total 0.OOOE+000 Halogens (Curies)
Isotope July 0.000E+000 August 0.000E+000 September 0.000E+000 Total 0.000E+000 Total Page 22 of 62
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2004 3rd Quarter Gaseous Release Continuous Mode Only August September Total Summary July Total Noble Gases (Ci) 0.OOOE+000 Total Halogens (Ci) 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.000E+000 Total Tritium (Ci) 5.882E-001 Total Particulate Gross Alpha (Ci) 0.000E+000 0.000E+000 0.000E+000 0.OOOE+000 0.000E+000 0.000E+000 0.OOOE+000 0.OOOE+000 0.000E+000 5.249E-001 0.000E+000 0.OOOE+000 0.OOOE+000 0.000E+000 1.1 13E+000 0.000E+000 Page 23 of 62
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2004 4th Quarter Gaseous Release Continuous Mode Only Noble Gasses (Curies)
Isotope Total October O.OOOE+000 November 0.000E+000 December 0.000E+000 Total 0.000E+000 Particulates (Curies)
Isotope Total October 0.000E+000 November O.OOOE+000 December O.OOOE+000 Total 0.000E+000 Halogens (Curies)
Isotope October Total O.OOOE+000 November 0.000E+000 December 0.000E+000 Total 0.OOOE+000 Page 24 of 62
Table 2.3B (Con't)
Annual Radioactive Effluent Release Report 2004 4th Quarter Gaseous Release Continuous Mode Only Summary October November December Total Total Noble Gases (Ci)
O.OOOE+000 Total Halogens (Ci) 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci)
O.OOOE+000 Total Tritium (Ci) 4.120E-001 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.000E+000 1.563E+001 0.OOOE+000 O.OOOE+000 0.OOOE+000 0.OOOE+000 8.926E-001 0.000E+000 0.OOOE+000 0.OOOE+000 0.000E+000 1.694E+001 0.OOOE+000 Page 25 of 62
Table 2.3C Annual Radioactive Effluent Release Report 2004 1st Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope January February March Total Ar-41 Xe-133 Xe-135 Total 2.192E-003 1.480E-003 0.000E+000 3.673E-003 O.OOOE+000 O.OOOE+000 0.000E+000 0.000E+000 O.OOOE+000 1.739E-003 1.308E-005 1.752E-003 2.192E-003 3.219E-003 1.308E-005 5.424E-003 Particulates (Curies)
Isotope January February March Total Total 0.000E+000 0.000E+000 0.000E+000 0.000E+000 Halogens (Curies)
Isotope January February March Total Total O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 Page 26 of 62
L L
I I.
L_
L K
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2004 1st Quarter Gaseous Release Batch Mode Only ary February March Tc Summary Janu; ital Total Noble Gases (Ci) 3.673E-003 Total Halogens (Ci) 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.000E+000 Total Tritium (Ci) 8.362E-001 Total Particulate Gross Alpha (Ci) 0.000E+000 0.OOOE+000 0.000E+000 0.OOOE+000 0.000E+000 0.000E+000 1.752E-003 0.000E+000 0.0 OE+000 2.196E-003 0.000E+000 5.424E-003 0.000E+000 0.0001E+000 8.384E-001 0.OOOE+000 Page 27 of 62
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2004 2nd Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope April May June Total I
Xe-133 Xe-135 i
Total 2.479E-004 0.000E+000 2.479E-004 3.627E-004 3.472E-006 3.662E-004 1.346E-003 0.OOOE+000 1.346E-003 1.956E-003 3.472E-006 1.960E-003 Particulates (Curies)
Isotope April May June Total Total 0.000E+000 0.000E+000 0.OOOE+000 0.0 OE+000 Halogens (Curies)
Isotope April May June Total Total 0.000E+000 O.OOOE+000 0.000E+000 0.000E+000 Page 28 of 62
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2004 2nd Quarter Gaseous Release Batch Mode Only I
May June Tc Summary Apri
)tal Total Noble Gases (Ci) 2.479E-004 Total Halogens (Ci) 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+000 Total Tritium (Ci) 6.887E-005 Total Particulate Gross Alpha (Ci) 0.000E+000 3.662E-004 O.OOOE+000 O.OOOE+000 4.298E-006 0.000E+000 1.346E-003 0.000E+000 0.OOOE+000 9.504E-004 O.OOOE+000 1.960E-003 O.OOOE+000 0.000E+000 1.024E-003 0.000E+000 Page 29 of 62
Table 2.3C (con't)
Annual Radioactive Effluent Release Report 2004 3rd Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope July August September Total Xe-133 Xe-135 Total 0.0006+000 0.000E+000 0.000E+000 0.000E+000 0.000E+000 0.000E+000 4.55116-003 3.2706-005 4.583E-003 4.55116-003 3.270E-005 4.583E-003 Particulates (Curies)
Isotope July August September Total Total 0.000E+000 0.000E+000 0.000E+000 0.000E+000 Halogens (Curies)
Isotope July August September Total Total 0.0006+000 0.0006+000 0.000E+000 0.0006+000 Page 30 of 62
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2004 3rd Quarter Gaseous Release Batch Mode Only Summary July August September Total Total Noble Gases (Ci) 0.000E+000 Total Halogens (Ci) 0.OOOE+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.000E+000 Total Tritium (Ci) 3.386E-005 0.000E+000 0.0001E+000 O.OOOE+000 0.OOOE+000 4.583E-003 0.000E+000 0.000E+000 1.953E-004 4.583E-003 0.OOOE+000 0.000E+000 2.292E-004 Total Particulate Gross Alpha (Ci) 0.OOOE+000 0.OOOE+000 0.000E+000 0.000E+000 Page 31 of 62
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2004 4th Quarter Gaseous Release Batch Mode Only Noble Gasses (Curies)
Isotope October November December Total Ar-41 Kr-85m Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Total 5.538E-003 6.376E-004 2.254E-004 9.4188E-004 7.412E-002 6.649E-004 3.256E-003 8.538E-002 0.OOOE3+000 0.OOOE+000 0.OOOE3+O00 0.OOOE3+000 0.OOOE3+000 0.OOOE+O000 0.OOOE1+000 0.OOOE3+000 0.000E+000 0.OOOE+000 0.000E+000 0.OOOE+000 0.000E+000 0.000E+000 0.000E+000 0.000E+000 5.5381E-003 6.376E-004 2.254E-004 9.418E-004 7.412E-002 6.649E-004 3.256E-003 8.538E-002 Particulates (Curies)
Isotope October November December Total Total 0.000E+000 0.OOO3+O000 0.OOOE+000 0.000E+000 Halogens (Curies)
Isotope October November December Total Total 0.OOOE+000 0.OOOE+000 0.000E+000 0.0003E+000 Page 32 of 62
Table 2.3C (Con't)
Annual Radioactive Effluent Release Report 2004 4th Quarter Gaseous Release Batch Mode Only Summary October November December Total L
Total Noble Gases (Ci) 8.538E-002 L
Total Halogens (Ci) 0.000E+000 Total Particulate Gross Beta-Gamma Half-Lives>8 Days (Ci) 0.OOOE+000 Total Tritium (Ci) 2.313E-001 Total Particulate Gross Alpha (Ci) 0.000E+000 0.0 OE+000 0.000E+000 0.000E+000 1.513E-004 0.OOOE+000 0.000E+000 0.000E+000 0.OOOE+000 2.545E-002 0.OOOE+000 8.538E-002 0.000E+000 0.000E+000 2.569E-001 0.000E+000 Page 33 of 62
Table 2.4 Annual Radioactive Effluent Release Report 2004 Dose From Gaseous Effluents The offsite dose limits from radioactive materials in gaseous effluents are specified in Section 3/4.4 of the Kewaunee ODCM and can be summarized as follows:
Whole Body Gamma Skin Beta Limit Organ Quarterly Annual 5.0 mRad 10.0 mRad 10.0 mRad 20.0 m.Rad 7.5 mRem 15.0 mnRem The total release of gaseous effluents during each quarter of 2004 was within limits. The following offsite doses were calculated using equations 2.7, 2.8, and 2.11 from the Kewaunee ODCM.
Calculated offsite doses versus quarterly limits are shown below:
I st Qtr 2nd Qtr 3rd Qtr 4th Qtr
- 1. Gamma-Whole Body Specification (mRads) 5.OOOE+000 Actual Dose (mRads) 2.459E-006
% of Specification 4.918E-005
- 2. Beta-Skin Specification (mRads) 1.000E+001 Actual Dose (mRads) 1.210E-006
% of Specification 1.210E-005
- 3. Ingestion Pathway-Organ Specification (niRems) 7.500E+000 Actual Dose (mnRems) 5.025E-005
% of Specification 6.700E-004 Liver 5.000E+000 7.957E-008 1.591E-006 1.000E+001 2.354E-007 2.354E-006 7.500E+000 1.507E-005 2.009E-004 Liver 5.000E+000 1.905E-007 3.81 OE-006 1.000E+001 5.545E-007 5.545E-006 7.500E+000 2.352E-005 3.136E-004.
Liver 5.0003E+000 1.148E-005 2.297E-004 1.OOOE+001 1.270E-005 1.270E-004 7.500E+000 3.632E-004 4.843E-003 Liver Page 34 of 62
Table 2.4 (Con't)
Annual Radioactive Effluent Release Report 2004 Dose From Gaseous Effluents In addition, the cumulative annual offsite doses for the period January 1 - December 31, 2004 versus the ODCM annual limits were:
Annual
- 1. Gamma-Whole Body Specification (mRads)
Actual Dose (mRads)
% of Specification
- 2. Beta-Skin Specification (rnRads)
Actual Dose (mRads)
% of Specification
- 3. Ingestion Pathway-Organ Specification (mRems)
Actual Dose (mRems)
% of Specification Liver 1.000E+001 1.421E-005 1.421E-004 2.000E+001 1.470E-005 7.352E-005 1.500E+001 4.520E-004 3.014E-003 Page 35 of 62
3.0 LIQUID EFFLUENTS 3.1 Lower Limits of Detection (LLD) for Liquid Effluents Liquid radioactive effluents are released as both batch releases and continuous releases. Each batch is sampled prior to release and analyzed for gamma emitters and tritium. A fraction of each sample is retained for a monthly proportional composite which is then analyzed for Gross Alpha, Strontium 89, Strontium 90 and Iron 55.
The LLD's for liquid batch release radioanalyses, as listed in Table 4.3 of the Kewaunee Nuclear Power Plant Off-Site Dose Calculation Manual, are:
Analysis Principal Gamma Emitters Iodine 131
- Tritium Gross Alpha Strontium 89, 90 Iron 55 LLD (IuCi/ml) 1.00 E-06 1.00 E-06 1.00 E-05 5.00 E-07 5.00 E-08 1.00 E-06 The actual obtained "a priori" LLD values for batch releases are shown below.
Isotope Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Cs-134 Cs-137 Ce-141 Ce-144 I-1 31 H-3 Sr-89 Sr-90 Gross Alpha Fe-55 1st Quarter 7.64E-10 1.70E-09 7.50E-10 1.12E-07 1.91E-09 5.40E-09 5.95E-10 7.38E-10 4.07E-08 5.47E-07 7.211E-08 3.10E-06 9.30E-09 6.701E-09 4.90E-09 9.60E-07 2nd Quarter 7.64E-08 1.69E-09 7.50E-10 1.12E-09 1.91E-09 5.96E-07 5.95E-10 7.94E-08 4.07E-08 4.09E-07 4.51E-10 2.95E-06 1.1OE-08 8.001E-09 5.30E-09 8.10E-07 3rd Quarter 7.64E-10 1.69E-07 7.50E-10 1.12E-09 1.90E-09 5.39E-09 1.01E-07 7.37E-10 5.75E-08 2.58E-07 4.51E-10 3.47E-06 1.30E-08 6.40E-09 5.20E-09 8.30E-07 4th Quarter 7.75E-08 1.72E-09 7.61E-10 1.62E-07 1.94E-09 7.73E-07 6.03E-10 7.47E-08 6.57E-08 3.49E-07 4.57E-08 3.53E-06 1.40E-08 1.20E-08 1.1OE-08 8.40E-07 Average a priori LLD (ACi/ml) 3.89E-08 4.35E-08 7.53E-10 6.911E-08 1.91E-09 3.45E-07 2.57E-08 3.89E-08 5.1 lE-08 3.91E-07 2.97E-08 3.26E-06 1.18E-08 8.28E-09 6.60E-09 8.60E-07 Page 36 of 62
Continuous liquid releases are grab sampled weekly and analyzed for principal gamma emitters. A fraction of each weekly sample is retained for a monthly proportional composite which is then analyzed for Tritium, Gross Alpha, Strontium 89, Strontium 90 and Iron 55.
The LLD's for liquid continuous release radioanalyses, as listed in Table 4.3 of the Kewaunee Nuclear Power Plant Off-Site Dose Calculation Manual, are:
Analysis LLD ([lCi/ml)
Principal Gamma Emitters Iodine 131 Tritium Gross Alpha Strontium 89, 90 Iron 55 5.00 E-07 1.00 E-06 1.00 E-05 5.00 E-07 5.00 E-08 1.00 E-06 The actual obtained "a priori" LLD values for continuous releases are shown below.
Isotope Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Cs-134 Cs-137 Ce-141 Ce-144 I-131 H-3 Sr-89 Sr-90 Gross Alpha Fe-55 1st Quarter 1.27E-08 3.99E-08 2.50E-08 1.68E-08 3.52E-08 2.67E-07 3.56E-08 4.73E-08 3.28E-08 8.07E-08 1.06E-08 3.1 OE-06 1.20E-08 8.15E-09 5.70E-09 7.60E-07 2nd Quarter 1.27E-10 7.59E-08 3.54E-08 1.87E-08 3.18E1-10 2.23E-07 7.01E-08 1.23E-10 5.66E-08 3.05E-10 1.30E-08 2.95E-06 1.15E-08 9.10E-09 5.60E-09 7.75E-07 3rd Quarter 3.60E-08 2.82E-08 1.38E-08 2.38E-08 3.18E-10 1.96E-07 3.08E-08 1.22E-10 2.79E-08 1.87E-07 3.93E-08 3.47E-06 1.30E-08 7.60E-09 5.65E-09 8.50E-07 4th Quarter 1.29E-08 2.87E-10 1.40E-08 3.43E-08 3.24E-10 2.05E-07 6.08E-08 4.35E-08 2.87E-08 1.40E-07 1.52E-08 3.53E-06 1.15E-08 9.OOE-09 7.05E-09 7.75E-07 Average a priori LLD (1iCiml) 1.54E-08 3.61E-08 2.20E-08 2.34E-08 9.04E-09 2.23E-07 4.93E-08 2.28E-08 3.65E-08 1.02E-07 1.95E-08 3.26E-06 1.20E-08 8.46E-09 6.00E-09 7.90E-07 Page 37 of 62
3.2 Liquid Batch Release Statistics The following is a summation of all liquid batch releases made during 2004.
Release Type A SGBT Monitor Tk.
B SGBT Monitor Tk.
A CVC Monitor B CVC Monitor Both WCTs Number 8
11 13 13 10 Gallons Released 73089.0 98389.0 85925.0 81550.0 17565.0 Total time for all batch releases........... 24353.0 Min.
Maximum time for a batch release......... 1 205.0 Min.
Minimum time for a batch release.............. 55.0 Min.
Average time for a batch release.............. 442.8 Min.
3.3 Liquid Effluent Data The following Table 3.1 presents a quarterly summation of the total activity released and average concentration for all liquid effluents. It also presents the gross alpha activity released, volume of waste released and volume of dilution water used. Tables 3.2 and 3.3 are monthly summations of the same information in Table 3.1. Table 3.2 contains the quantity of the individual isotopes released to the unrestricted area for batch releases. Table 3.3 presents a monthly summation of gross radioactivity, tritium, gross alpha and isotopic activity for the secondary blowdown and leakage releases. It also presents the monthly total volume for these releases and dilution volumes. Table 3.4 presents the doses from liquid effluents for each quarter and the calculated doses this year from liquid effluents.
Page 38 of 62
TABLE 3.1 Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Summation of all Releases 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Fission and Activation Products Total Release Excluding H3 and Dissolved Gases (Ci)
Average Concentration
([tCi/ml)
Tritium Total Release (Ci)
Average Concentration (gCi/ml)
% of Tech. Spec.
Limit(3.0OE-3 pCi/ml)
Dissolved Gases Total Release (Ci)
Average Concentration (PiCi/ml)
% of Tech. Spec.
Limit(2.OE-4 jiCi/ml)
Gross Alpha Activity Total Release (Ci)
Volume of Waste Released Batch (liters)
Continuous (liters)
Total (liters)
Volume of Dilution Water Batch (liters)
Continuous (liters)
Total (liters) 2.929E-004 3.538E-012 1.802E+002 2.177E-006 7.256E-002 O.OOOE+000 O.OOOE+000 0.OOOE+000 O.OOOE+000 2.561E+005 2.426E+007 2.452E+007 5.015E+009 7.776E+010 8.278E+010 7.071E-003 3.865E-01 1 2.898E+001 1.584E-007 5.280E-003 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 1.377E+005 2.041E+007 2.055E+007 2.481E+009 1.805E+011 1.829E+011 3.298E-004 1.559E-012 2.262E+002 1.069E-006 3.564E-002 0.000E+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 4.132E+005 1.739E+007 1.780E+007 1.094E+010 2.006E+01 1 2.115E+011 1.652E-002 1.546E-010 3.442E-+001 3.222E-007 1.074E-002 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 5.425E+005 2.294E+007 2.348E+007 6.344E+009 1.005E+01 1 1.068E+011 Page 39 of 62
TABLE 3.2A Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases January February March Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 1.696E-005 Avg. Conc.
(JCi/ml) 2.042E-01 1 Tritium Total Release (Ci) 5.782E+001 Avg. Conc.
(jiCi/ml) 6.962E-005 Dissolved Gases Total Release (Ci)
O.OOOE+000 Avg. Conc.
(PiCi/ml)
O.OOOE+000 Gross Alpha Activity Total Release (Ci)
O.OOOE+000 Avg. Conc.
(jICi/ml)
O.OOOE+000 Volume of Waste Released (liters) 5.801E+004 Volume of Dilution Water (liters) 8.305E+008 1.183E-004 3.019E-01 1 1.171E+002 2.986E-005 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 1.649E+005 3.920E+009 8.557E-005 3.239E-010 5.320E+000 2.014E-005 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 3.325E+004 2.642E+008 2.209E-004 1.802E+002 O.OOOE+000 O.OOOE+000 2.561E+005 5.01 5E+009 L
Page 40 of 62
TABLE 3.2A (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases Isotope (Ci)
January February March Total H-3 Fe-55 Co-58 Sr-90 Ag-i lOm Sb-125 Total 5.782E+O00I 1.682E-005 O.OOOE+000 1.392E-007 O.OOOE+O0O 0.OOOE+000 5.782E+001 1.171E+002 4.781E-005 2.595E-005 3.957E-007 1.501E-005 2.9188E-005 1.171E+002 5.320E+000 9.643E-006 O.OOOE+000 7.980E-008 1.933E-005 5.653E-005 5.320E+000 1.802E+002 7.428E-005 2.595E-005 6.147E-007 3.434E-005 8.570E-005 1.802E+002 Page 41 of 62
TABLE 3.2B Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases April May June Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 1.428E-006 Avg. Conc.
(,uCi/ml) 1.722E-012 Tritium Total Release (Ci) 2.387E+001 Avg. Conc.
(pCi/ml) 2.879E-005 Dissolved Gases Total Release (Ci)
O.OOOE+000 Avg. Cone.
(AiCifml)
O.OOOE+000 2.325E-005 2.517E-01 1 3.05 1E+000 3.303E-006 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 3.447E+004 9.236E+008 8.147E-005 1.11 9E-010 2.063E+000 2.832E-006 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 4.1 15E+004 7.283E+008 1.062E-004 2.898E+001 O.OOOE+000 O.OOOE+000 1.377E+005 2.481E+009 Gross Alpha Activity Total Release (Ci)
O.OOOE+000 Avg. Cone.
(PiCi/ml)
O.OOOE+000 Volume of Waste Released (liters) 6.207E+004 Volume of Dilution Water (liters) 8.290E+008 Page 42 of 62
TABLE 3.2B (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases Isotope (Ci)
April May June Total H-3 Fe-55 Sr-89 Sr-90 Sb-125 Total 2.387E+001 1.241E-006 6.828E-008 1.179E-007 0.OOOE+000 2.387E+001 3.051E+000 6.895E-007 3.792E-008 6.550E-008 2.246E-005 3.05 1E+000 2.063E+000 8.23 1E-007 4.527E-008 7.81 9E-008 8.052E-005 2.063E+000 2.898E+001 2.754E-006 1.515E-007 2.616E-007 1.030E-004 2.898E+001 Page 43 of 62
TABLE 3.2C Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases July August September Total Gross Radioactivity L
Total Release Excluding H3 and Dissolved Gases (Ci) 8;164E-005 Avg. Conc.
(iPCi/ml) 2.862E-011 Tritium Total Release (Ci) 7.067E+001 Avg. Conc.
-(iCi/ml) 2.477E-005 Dissolved Gases Total Release (Ci)
O.OOOE+000 Avg. Conc.
(+/-tCi/ml)
O.OOOE+000 Gross Alpha Activity L
Total Release (Ci)
O.OOOE+000 Avg. Conc.
(,tCi/ml)
O.OOOE+000 Volume of Waste Released (liters) 1.095E+005 Volume of Dilution Water (liters) 2.853E+009 2.708E-007 1.431E-012 4.561E-005 2.4 1OE-01 0 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 6.889E+003 1.893E+008 1.336E-004 1.691E-011 1.555E+002 1.968E-005 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 2.968E+005 7.901E+009 2.155E-004 2.262E+002 O.OOOE+000 O.OOOE+000 4.132E+005 1.094E+010 Page 44 of 62
TABLE 3.2C (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases Isotope (Ci)
July August September Total H-3 Fe-55 Sr-89 Sr-90 Ag-i lOm Sb-125 Total 7.067E+001 3.286E-006 9.858E-007 3.286E-008 O.OOOE+OO0 7.733E-005 7.067E+001 4.561E-005 2.067E-007 6.200E-008 2.067E-009 O.OOOE+O0O O.OOOE+000 4.588E-005 1.555E+002 8.903E-006 2.671E-006 8.903E-008 1.1 87E-005 1.1003E-004 1.555E+002 2.262E+002 1.240E-005 3.719E-006 1.240E-007 1.187E-005 1.874E-004 2.262E+002 Page 45 of 62
TABLE 3.2D Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases October November December Total Gross Radioactivity L
Total Release Excluding H3 and Dissolved L
Gases (Ci) 6.128E-003 Avg. Conc.
(1iCi/mI) 3.703E-009 Tritium Total Release (Ci) 7.328E+000 Avg. Conc.
([LCi/ml) 4.428E-006 Dissolved Gases Total Release (Ci)
O.OOOE+000 Avg. Conc.
(jiCilml)
O.OOOE+000 Gross Alpha Activity L
Total Release (Ci)
O.OOOE+000 Avg. Conc.
(PiCi/ml)
O.OOOE+000 L
Volume of Waste Released (liters) 1.357E+005 Volume of Dilution Water (liters) 1.655E+009 8.21 lE-003 2.286E-009 2.245E+001 6.25 1E-006 O.OOOE+000 O.OOOE+000 O.OOOE+O00 O.OOOE+000 3.044E+005 3.592E+009 1.344E-003 1.225E-009 4.637E+000 4.227E-006 O.OOOE+OO0 O.OOOE+OOO 0.OOOE+000 O.OOOE+OO0 1.024E+005 1.097E+009 1.568E-002 3.442E+001 O.OOOE+000 O.OOOE+000 5.425E+005 6.344E+009 Page 46 of 62
TABLE 3.2D (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Batch Releases Isotope (Ci)
October November December Total H-3 Cr-51 Mn-54 Fe-55 Co-58 Fe-59 Co-60 Sr-90 Nb-95 Ag-llOm Sb-125 Total 7.328E+000 0.000E+000 8.539E-005 1.493E-004 2.599E-004 O.OOOE+000 1.360E-003 2.850E-007 0.000E+000 2.460E-003 1.813E-003 7.334E+000 2.245E+001 1.640E-003 8.200E-005 3.348E-004 2.774E-003 2.9188E-004 1.232E-003 6.392E-007 1.024E-004 1.755E-003 0.OOOE+000 2.246E+001 4.637E+000 0.000E+000 1.826E-005 1.127E-004 8.348E-004 0.000E+000 1.490E-004 2.15 1E-007 2.0133E-005 2.086E-004 0.000E+000 4.639E+000 3.442E+001 1.640E-003 1.856E-004 5.968E-004 3.869E-003 2.9188E-004 2.7411E-003 1.139E-006 1.226E-004 4.424E-003 1.813E-003 3.443E+001 Page 47 of 62
TABLE 3.3A Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases January February March Total Gross Radioactivity
- [
Total Release Excluding H3 and Dissolved Gases (Ci) 2.055E-005 Avg. Conc.
(PCi/ml) 1.663E-012 Tritium L
Total Release (Ci) 0.OOOE+000 Avg. Conc.
([iCi/ml)
O.OOOE+000 Dissolved Gases Total Release (Ci)
O.OOOE+000 Avg. Conc.
(1Ci/ml)
O.OOOE+000 L
Gross Alpha Activity L
Total Release (Ci)
O.OOOE+000 Avg. Conc.
(,uCi/ml)
O.OOOE+000 Volume of Waste Released (liters) 7.149E+006 Volume of Dilution Water (liters) 1.235E+010 L.
2.906E-005 9.191E-013 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 8.938E+006 3.162E+010 2.237E-005 6.618E-013 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 8.175E+006 3.380E+010 7.197E-005 O.OOOE+000 0.OOOE+000 O.OOOE+000 2.426E+007 7.776E+010 Page 48 of 62
TABLE 3.3A (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases Isotope (Ci)
January February March Total Sr-89 Sr-90 Total 1.545E-005 5.091E-006 2.055E-005 2.246E-005 6.600E-006 2.906E-005 1.662E-005 5.743E-006 2.237E-005 5.453E-005 1.743E-005 7.197E-005 Page 49 of 62
TABLE 3.3B Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases I
May June To Apri]
ital Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 2.057E-003 Avg. Conc.
(ACi/ml) 4.334E-01 1 Tritium Total Release (Ci)
O.OOOE+000 Avg. Conc.
(iCi/ml)
O.OOOE+000 Dissolved Gases Total Release L
(Ci)
O.OOOE+000 Avg. Conc.
L (iCi/ml)
O.OOOE+000 Gross Alpha Activity L
Total Release (Ci)
O.OOOE+000 Avg. Conc.
L (jICi/ml)
O.OOOE+000 Volume of Waste Released (liters)
-5.824E+006 L
Volume of Dilution Water (liters) 4.746E+010 2.899E-003 4.289E-01 1 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 8.602E+006 6.759E+010 2.009E-003 3.071E-0 1I O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 5.988E+006 6.541E+010 6.965E-003 O.OOOE+060 0.OOOE+000 O.OOOE+000 2.041E+007 1.805E+011 Page 50 of 62
TABLE 3.3B (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases Isotope (Ci)
April May June Total Fe-55 Sr-89 Sr-90 Total 2.038E-003 1.747E-005 1.165E-006 2.057E-003 2.872E-003 2.474E-005 2.790E-006 2.899E-003 1.990E-003 1.715E-005 2.0144E-006 2.009E-003 6.899E-003 5.935E-005 5.969E-006 6.965E-003 Page 51 of 62
TABLE 3.3C Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases July August September Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 3.191E-005 Avg. Conc.
(PUCimi) 4.720E-013 Tritium Total Release (Ci) 2.538E-004 Avg. Conc.
(11Ci/ml) 3.755E-012 Dissolved Gases Total Release (Ci)
O.OOOE+000 Avg. Conc.
(PCi/ml)
O.OOOE+000 5.506E-005 8.146E-013 5.845E-004 8.647E-012 O.OOOE+000 O.OOOE+000 O.OOOE+000 0.OOOE+000 5.486E+006 6.759E+010 2.739E-005 4.187E-013 4.852E-005 7.418E-013 O.OOOE+000 O.OOOE+000 O.OOOE+000 O.OOOE+000 7.166E+006 6.541E+010
- 1. 144E-004 8.868E-004 O.OOOE+000 O.OOOE+000 1.739E+007 2.006E+011 Gross Alpha Activity Total Release (Ci)
O.OOOE+000 Avg. Conc.
(PCi/ml)
O.OOOE+000 Volume of Waste Released (liters) 4.734E+006 Volume of Dilution Water (liters) 6.759E+010 Page 52 of 62
TABLE 3.3C (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases Isotope (Ci)
July August September Total H-3 Fe-55 Sr-89 Sr-90 Total 2.538E-004 1.596E-005 1.407E-005 1.873E-006 2.857E-004 5.845E-004 3.675E-005 1.616E-005 2.147E-006 6.396E-004 4.852E-005 3.05 1E-006 2.147E-005 2.863E-006 7.591E-005 8.868E-004 5.576E-005 5.171E-005 6.883E-006 1.OO1E-003 Page 53 of 62
TABLE 3.3D Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases October November December Total Gross Radioactivity Total Release Excluding H3 and Dissolved Gases (Ci) 1.601E-005 Avg. Conc.
(jiCi/ml) 4.708E-013 Tritium Total Release (Ci) 0.OOOE+000 Avg. Conc.
(jiCi/mi)
O.OOOE+000 Dissolved Gases Total Release (Ci) 0.OOOE+000 Avg. Conc.
(pCi/ml) 0.OOOE+000 2.729E-004 8.343E-012 O.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 5.487E-004 1.624E-01 1 0.OOOE+000 0.OOOE+000 0.OOOE+000 0.OOOE+000 8.376E-004 0.000E+000 0.OOOE+000 Gross Alpha Activity Total Release
- (Ci) 0.OOOE+000 Avg. Conc.
(11Ciml)
O.OOOE+000 Volume of Waste Released (liters) 4.212E+006 Volume of Dilution Water (liters) 3.399E+010 0.OOOE+000 O.OOOE+000 9.643E+006 3.271E+010 0.OOOE+000 O.OOOE+000 9.085E+006 3.380E+010 0.OOOE+000 2.294E+007 1.005E+01 1 Page 54 of 62
TABLE 3.3D (Con't)
Annual Radioactive Effluent Release Report 2004 Liquid Effluents - Continuous Releases Isotope (Ci)
October November December Total Fe-55 Co-58 Sr-89 Total 0.000E+000 0.000E+000 1.601E-005 1.6011E-005 2.153E-004 2.025E-005 3.733E-005 2.729E-004 5.125E-004 0.000E+000 3.6166E-005 5.487E-004 7.278E-004 2.025E-005 8.950E-005 8.376E-004 Page 55 of 62
Table 3.4 Annual Radioactive Effluent Report 2004 Dose From Liquid Effluents The dose to a member of the public from total liquid radioactive releases for each quarter was below the ODCM limits of 1.5 mrems to the total body and less than or equal to 5 mrems to any organ.
Additionally, the dose to a member of the public from total liquid radioactive releases for the year was below the ODCM limits of 3 mrems to the total body and less than or equal to 10 mrems to any organ.
Instantaneous release concentrations are limited by the individual radionuclide concentrations established in 10 CFR 20, Appendix B, for unrestricted areas. During the report period, none of the isotopes released exceed the concentrations specified in Appendix B. The following offsite doses were calculated using equation 1.5 from the Kewaunee ODCM.
Organ 1 st Qtr Dose Dose Total mRem Quarterly Limit mRem Percent of Limit Total Body Bone Liver Thyroid Kidney Lung GI-LLI Organ 2nd Qtr Dose Total Body Bone Liver Thyroid Kidney Lung GI-LLI 1.311E-003 8.562E-006 1.31 OE-003 1.309E-003 1.309E-003 1.309E-003 1.3111E-003 Dose Total mRem 1.925E-004 2.318E-006 1.920E-004 1.919E-004 1.919E-004 1.920E-004 1.921E-004 1.5 5.0 5.0 5.0 5.0 5.0 5.0 Quarterly Limit mRem 1.5 5.0 5.0 5.0 5.0 5.0 5.0 0.09 0.00 0.03 0.03 0.03 0.03 0.03 Percent of Limit 0.01 0.00 0.00 0.00 0.00 0.00 0.00 Page 56 of 62
Table 3.4 (Con't)
Annual Radioactive Effluent Report 2004 Dose From Liquid Effluents Organ 3rd Qtr Dose Dose Total mRem Quarterly Limit mRem Percent of Limit Total Body Bone Liver Thyroid Kidney Lung GI-LLI Organ 4th Qtr Dose Total Body Bone Liver Thyroid Kidney Lung GI-LLI 8.325E-004 5.674E-005 8.220E-004 8.216E-004 8.216E-004 8.218E-004 8.254E-004 Dose Total mRem 3.196E-004 8.940E-005 3.212E-004 2.501E-004 2.562E-004 2.622E-004 4.948E-003 1.5 5.0 5.0 5.0 5.0 5.0 5.0 Quarterly Limit mRem 1.5 5.0 5.0 5.0 5.0 5.0 5.0 0.06 0.00 0.02 0.02 0.02 0.02 0.02 Percent of Limit 0.02 0.00 0.01 0.01 0.01 0.01 0.10 Calculated Dose This Year Organ Dose Total mRem Quarterly Limit mRem Percent of Limit Total Body Bone Liver Thyroid Kidney Lung GI-LLI 2.656E-003 1.570E-004 2.645E-003 2.573E-003 2.579E-003 2.585E-003 7.277E-003 3.0 10.0 10.0 10.0 10.0 10.0 10.0 0.09 0.00 0.03 0.03 0.03 0.03 0.07 Page 57 of 62
L 4.0 UNPLANNED RELEASES No unplanned releases were made from the Kewaunee Plant during the report period.
5.0 METEOROLOGICAL DATA Meteorological data for 2004 is retained on file at the Kewaunee Nuclear Power Plant. The data on file includes a continuous strip chart recording and a 15-minute interval listing of wind speed, wind L
direction and atmospheric stability. This is more conservative than the requirements of ODCM Section 3/4.7. See Appendix A for missing meteorological data and the joint frequency distribution tables.
6.0 SOLID WASTE DISPOSAL Table 6.1 is a summation of solid wastes shipped during 2004. Presented are the types of wastes, major nuclide composition, disposition of the wastes and shipping containers used.
L The containers utilized at Kewaunee Nuclear Power Plant have the following volumes:
L High Integrity Container (HIC) 158 ft3 High Integrity Container (HIC) 120.3 ft3 LSA Box (B-25) 98 ft3 L
Compactor Box (CPC 50) 50 ft3 55 Gal Steel Drum 7.5 i13 Table 6.1 contains the radionuclide content (curies) and percent abundance for each type of waste.
Page 58 of 62
Table 6.1 Annual Radioactive Effluent Report 2004 Solid Waste and Irradiated Fuel Shipments A. Solid Waste Shipped Off-Site for Burial or Disposal (Not Irradiated Fuel - m3 is actual waste volume not burial volume)
- 1. Type of Waste Unit Quantity
- a.
Resin m 3 None Container: HIC Ci None
- b.
Dewatered filter media m3 None Container: HIC Ci None
- c.
DAW (Compactible) m3 1.62E+01 Container: CPC 50 Ci 1.01E-01
- d.
DAW (Non-Compactible) m3 1.30E+02 Container: Meets Requirements of Ci 2.07E+01 49 CFR 173.24,173.24A and 173.410 Average Transuranics shipped (all shipments):
1.68E-OlnCi/g
- 2. Estimate of Major Nuclide by Composition (By Type of Waste)
Ci
- a.
Resin None None
- b.
Dewatered filter media None None
- c.
DAW (Compactible) 100%
1.01E-01 Cr-5I 1.08E-03 1.09E-04 Mn-54 2.1OE-02 2.1 1E-03 Co-58 5.42E-02 5.46E-03 Co-60 4.80E-01 4.83E-02 Zr-95 1.2QE-02 1.21E-03 Nb-95 8.61E-03 8.67E-04 Ag-110m 3.03E-03 3.05E-04 Cs-137 2.72E-03 2.74E-04 Sb-125 4.17E-02 4.20E-03 Fe-55 1.77E-01 1.78E-02 Fe-59 1.47E-04 1.48E-05 H-3.
L1OE-02 l.llE-03 Ni-63 1.88E-01 1.89E-02 Page 59 of 62
- d.
DAW (Non-Compactible) 100%
2.07E+Ol Cr-51 Mn-54 Co-57 Co-58 Co-60 Zr-95 Nb-95 Ag-i lOm Cs-134 Cs-137 Sb-124 Sb-125 Fe-55 Fe-59 C-14 Tc-99 Nb-94 TRU Pu-241 Am-241 H-3 Ni-63 Sr-90 Zn-65 Ag-108m Ba-140 Ce-141 Cm-242 Cm-243 Pu-239 Ru-103 W-187 9.41E-03 1.388E-02 1.47E-03 3.99E-Ol 1.23E-0O 6.09E-03 2.64E-02 3.96E-04 1.68E-04 3.63E-04 1.38E-04 1.96E-03 2.55E-Ol 4.48E-03 8.86E-03 6.1 OE-03 4.1OE-05 8.37E-04 7.94E-04 2.74E-05 7.70E-06 1.37E-Oi 6.588E-04 8.61E-04 1.74E-03 1.56E-03 3.10E-04 1.03E-06 3.60E-06 2.69E-06 2.14E-04 2.96E-04 1.95E-Ol 2.85E-01 3.05E-02 8.27E+00 2.55E+00 1.26E-Ol 5.48E-0O 8.21E-03 3.49E-03 7.5 lE-03 2.86E-03 4.07E-02 5.28E+00 9.28E-02 1.84E-0O 1.26E-01 8.51E-04 1.73E-02 1.65E-02 5.68E-04 1.60E-04 2.84E+00 1.36E-02 1.79E-02 3.61E-02 3.24E-02 6.44E-03 2.14E-05 7.46E-05 5.57E-05 4.43E-03 6.13E-03 Page 60 of 62
- 3. Solid Waste Disposition
- a.
Date of Shipment Mode of Transportation Destination 06/02/04 06/09/04 09/16/04 11/15/04 12/13/04 12/17/04 R&R Trucking (Van)
R&R Trucking (Flatbed)
R&R Trucking (Flatbed)
Perkins Specialized Transportation Hittman Transportation (Flatbed)
RACE Logistics LLC (Flatbed)
RACE LLC Memphis, TN RACE LLC Memphis, TN RACE LLC Memphis, TN Envirocare of Utah Clive Disposal Site Clive, UT Envirocare of Utah Clive Disposal Site Clive, UT RACE LLC Memphis, TN B.
Irradiated Fuel Shipments None.
Page 61 of 62
7.0 PROGRAM REVISIONS In accordance with Technical Specifications 6.18.b.3 and 6.19.a, the revisions to the Process Control Program, Offsite Dose Calculation Manual and radioactive wvaste treatment systems are listed below.
7.1 Offsite Dose Calculation Manual The Offsite Dose Calculation Manual (ODCM) has not been revised during this report period.
7.2 Major Changes to the Radioactive Liquid, Gaseous and Solid Waste Treatment Systems Major changes to the radioactive liquid, gaseous or solid waste systems are submitted in the annual Updated Final Safety Analysis Report consistent with Technical Specification 6.19.
8.0 REPORTABLE OCCURRENCES None.
I L
L L
I~
L L
Page 62 of 62
Appendix A Kewaunee Nuclear Power Plant 2004 Meteorological Data Missing Data First Quarter: 5.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br /> Second Quarter: 222.50 hours5.787037e-4 days <br />0.0139 hours <br />8.267196e-5 weeks <br />1.9025e-5 months <br /> Third Quarter: 123.50 hours5.787037e-4 days <br />0.0139 hours <br />8.267196e-5 weeks <br />1.9025e-5 months <br /> Fourth Quarter: 37.00 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> Note:
A total of 388.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br /> of data is missing or othenvise unavailable. This represents the availability of 95.6 % of the data for the year. Continuous strip chart indication for 2004 data is available onsite.
APPENDIX A Annual Radioactive Effluent Release Report 2004 FIRST QUARTER 2004 Total Hours Missing = 5.75 Stabitity Class A Wind Direction Total Hours = 2184 N
NNE NE ENE E
SSW.
SW WSW W
WNW NW NNW TOTAL CALM 0
0 0
0 0
0 0
0 0
.0 0.
.0
.0 0
0 O 0
0 1-3 0
0 0.25 0.5 0.25 0.25 0.75 0.25 0 1
- 0 0
0 1.5 0.25 0.25 4
4.25 4-7 2.25 0.25 2.25 0
0.75 0.25 1.25 0.75 2.25 6
2.5 1.5 8.25 6.5 10.75 6.5 52 8-12 16.75 5
24.5 17.75 4.25 8.25 6
11.
13.25 2.75 1.5 3.25 13.5 17.25 23.25 14.5 182.75 13-18 12.5 10.25 9
19.5 20.25 3.75 7.75 16.75 12.5 2.5 3.25 13.25 17.75 31.75 8.75 3
192.5 19-24 1.25 1.5 1.75 5
19 0
0 6.5 10.25 0
0 0
5.75 6
2.5 3.5 63
>24 0
0 0
0 0.25 0
3.5 1.75
- 0 0
0 1.75 0.25 0
0 7.5 TOTAL 32.75 17 37.75 42.75 44.75 12.5 15.75 38.75 40 11.25 7.25 18 48.5 62 45;5 27.5 502 Stability Class B Wind Direction CALM N.
NNE NE ENE E
- SS SSW
.SW WSW.
W WNW NW NNW TOTAL 0
0 0
0 0
0 0
0 0
0 0
0 0
0, 0.
0 0
1-3 0.25 0
0 0
0 0
0 0
. 0 0
0 0
0 0.
.0.
0.25 4-7 1
0 0
0 0.
1.5 1.25 0.25 1.75 3.25 3.25 0
0.75 0.75 0.75 2.5 17 8-12 11.75 2
0
- 1 2
0.25 1.5 3
1 2.5 0
0.25 5.25 4.5 3.25 7.25 45.5 13-18 6
4.5 0
4.75 4.5 1.75 0.5 16.5 0.25 0.25 2
2.25 4.75 5.75 4
6.25 64 19-24 0
0.5 0.25 0
0 0
0 1.25 0
0
.0 0
2.25 0.5 0.25 0.75 5.75
>24 0
0 0
0 0
0
-0 0
0.75 0
0 0
0 0
0 0
0.75 TOTAL 19 7
0.25 5.75 6.5 3.5.
3.25 21 3.75 6
5.25 2.5 13 11.5 8.25 16.75 133.25 Page A2ofA15
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class C Wind Direction N
NNE NE ENE E
W WNW NW NNW TOTAL CALM 0
0 0
0 0
0 0
0 0
0 0
0.
0
.0 0
0 0
1-3 0
0.25 0.25 0
0
'1 0
0 0.25 0
0 0
0 0.5 0*
0 2.25 4-7 2.5 0
0 0
0 1
2.25 0.25 2
3.25 3.25 1.25 4
2 1.75 4.25 27.75 8-12 10.75 7
2.5 2.75 3.5 3.25 0.5 5.25 3.25 2.5 0.75 0.75 8.25 6.5 5
9.
71.5 13-18 5.25 9.5
- 0 0.75 0
0 0.5 3.5 0
0.75 2.75 2.5 3
6.75 0.75 6.75 42.75 19-24 1.5 0
0 0
0 0
0 0.25 0.25 0.25 0
1.25 2.25 0.25 0
5.25 11.25
>24 0
0
.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 TOTAL 20 16.75 2.75 3.5 3.5 5.25 3.25 9.25 5.75 6.75 6.75 5.75 17.5 16 7.5 25.25 155.5 Stabitity Class D Wind Direction N
NNE NE ENE E
ESE
WNW NW NNW TOTAL CALM 0
0 0
0 0
0 0
0 0
0 0
0 0
0
- 0.
0 0
1-3 0.25 0
0.25 0.25 1.25 4.25 1.25 1
0.25 0.
1.25 0.75 0.5 0.25 0.25
. 0 11.75 4-7 6.5 1.5 1.25 0.25 2.75 3.5 2.5 4
7.5 10 9.75 10.5 11.5 12.75 9.25 12 105.5 8-12 34 12.5 2
2.5 1
1.5 3.75 17.5 9.5 33 12.5 7.75 27.25 20 21.75 36.25 242.75 13-18 6
4.5 2.5 7.75 2.5 3.75 0.25 10.75 3.25 6.25 9.25 10.5 28.5 30.75 15.75 21.25 163.5 19-24 2
0.5 0.25 0
0 1.25 0
0 2.25 0.
5.75 6
6.75 4.75 2.25 3.25 35
>24
.0 1.5 0
0 0
0 0
0 0
0 0
0 0
.0 0
1.5 TOTAL 48.75 20.5 6.25 10.75 7.5 14.25 7.75 33.25 22.75 49.25 38.5 35.5 74.5 68.5 49.25 72.75 560 Page A3 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class E Wind Direction CALM N
NNE NE ENE E
.W WNW NW NNW TOTAL 0.25 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.25 1-3 1.5 1.25 1
1 1
1.25 1
1.25 0.5 0.5 1.25 2.25 1
1.5 1.5 1.25 19 4-7 4.5 1.25 1
0.5 0.75 1.75 2.5 4.75 9.75 13.25 10.5 10.5.
9.25 15.25 7.25 18.25 111 8-12 16.5 12.5 1
4.5 4
2.5 4
8 7
15.25
.11.75 13.5 31 28.5 10.75 15.25 186 13-18 1.5 0
0 0
0 0
3 4.5 5
0 6.25 22.5 12.5 7
1.25 5
68.5 19-24 0.75 0
0 0 '
0 0
0 3
2 0
0 4
1.75 1
0 0
12.5
>24 0
0 0
0 0
0 0
0 0.5 0
0 0
0
.0 0 O 0
0.5 TOTAL 25 15 3
6 5.75 5.5 10.5 21.5 24.75 29 29.75 52.75 55.5 53.25 20.75 39.75 397.75 Stabitity Class F Wind Direction N
NNE NE ENE E
WNW NW NNW TOTAL CALM 0O 0
0 0
0
- 0 0
0 0
0 0
0~
0
.0 0
0 0
1-3 1
0.5 0
0 0.5 0.5 0.5 0.25 1
1.5 4.75 4
3.25 0.75 1.5 6.5 26.5 4-7 1.75 2.25 0.75 0.5 0.75 0.25 3.75 3.75 6
10.25 8
10 8
9.25 11.25 5
81.5 8-12 1.75 0.25 0
.0 0
0.25 0.75 1.5 5
2 7.75 7.25 5.25 21.5 8.25 10.75 72.25 13-18 0
0 0
0 0
0 0
1.5 0
0 0
2.25 0.5 0
0 0
4.25 19-24 0
0 0
0 0
0 0
0.5 0
-0 0
0 0
0 0.
0 0.5
>24 0
0.
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 4.5
.3 0.75
.0.5 1.25
.1 5
.7.5 12 13.75 20.5 23.5 17 31.5 21 22.25 185 Page A4 of A15
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class G Wind Direction CALM N
NNE NE ENE E
WNW NW NNW TOTAL 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1-3 2.25 0.25 0.25 0.75 0
0.75 0
0.75 1.25 2.75 2.25 2.75 1
1.25 2.75 6.25 25.25 4-7 6.75 0.75 3
0 0.75 0
0.5 8
10 22.5 16.5 16.25 27.5 17.25 22.75 19 171.5 8-12 2.5 0
0 0.25 0
0 0
3.75 4
0 7
6.75 15.5 6
2 0.25 48 13-18 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 19-24 0
0 0
0 0
0 0
0 0
0 0
0 0*
0 0
0 0
>24 0
0 0
0
.0 0
0 0
0 0
0 0
0 0
0 0
0 TOTAL 11.5 1
3.25 1
0.75 0.75 0.5 12.5 15.25 25.25 25.75 25.75 44 24.5 27.5 25.5 244.75 2nd QUARTER 2004 Total Hours Missing = 222.5 Stabitity Class A Total Hours = 2184 Wind Direction N
NNE NE ENE E
WNW NW NNW TOTAL CALM 1-3 0.5 0.5 0
0.5 0
.0 0
0 0
0 0
0 0
0.25 0
0 0
0 0
0.25 0
0
- 0.
0 0
0
.0 0
0 0.25 0
0.25 0.5 2
4-7 6
1.75 4.5 5
8.25 14
.9 8.5 2.5 4.25 4
1.75 3.75 8.25 11.5 11.75 104.75 8-12 19.75 32.5 60.5 8
6.25 10.75 7.5 8.25 11.25 7
17 7.75 7.75 10 12 13 13-18 3.5 45.5 17.25 0.5 0
2.25 0.5 9.5 5.75 0
.3.75 4.5 1.75 6.75 3
3.75 19-24 0.75 2
0 0
0 0
0 1.5 0
0 1.75 0.75 0
1.75 1.5 4
14
>24 0.25 0
0 0
0 0
0 1.75 0
0 0.5 0
0 0
0 0.5 3
TOTAL
.31.25 82.25 82.25 13.5 14.5
- 27 17.25 29.5 19.5 11.5 27 14.75 13.25 26.75 28.25 33.25 471.75 239.25 108.25 Page A5 of A15
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class B Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 0.25 1.25 1.25 0
1 0
3.75 NNE 0
0.25 2.25 8.25 10.75 1.25 0
22.75 NE 0
0 2.5 7.25 1
0.25 0
11 ENE 0
0 1
0.75 0
0 0
1.75 E
0 0
1.25 0.5 0
0 0
1.75 ESE 0
0 0.75 0
1.75 0.75 0
3.25 SE 0
0 2
2.5 0
0 0
4.5 SSE 0
0 1.5 2
0.75 0.25 0
4.5 S
0 0
0.25 9
2.5 0
0 11.75 SSW 0
0 0
2.75 0
0 0
2.75 SW 0
0 0
0.5 0
0.5 0.25 1.25 WSW 0
0 1.25 0.25 0
0 0
1.5 W
0 0.25 0.25 0.25 0
0 0
0.75 WNW 0
0 1.75 2
1.75 0.25 0
5.75 NW 0
0.25 1.5 1.5 0.25 1.5 0
5 NNW 0
0.25 1.25 2.75 1
0 0
5.25 TOTAL 0
1.25 18.75 41.5 19.75 5.75 0.25 87.25 Stabitity Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 1
2.75 0.75 1.75 1
0 7.25 NNE
- 0.
0 2.25 14 15.25 2.5 0
34 NE 0
0.25 1
10.25 2.75 0
0 14.25 ENE 0
0 1.25 3.5 0.25 0
0
.5
-E 0
0 2.25 3
1.25 0
0 6.5 ESE 0
0 0.5
- 0.
0 0
0 0.5 SE 0
0 2
4.75 0
0 0
6.75 SSE 0
0 1
2 0.25 0.5 0
3.75 S -
0 0
0.25 4
0.5 0
0 4.75 SSW 0
0 0.25 4.25
.0 0
0 4.5 SW 0
0 0.25 0.5 0
0.75 0
1.5 WSW 0
0 0.75 0.5 0.25 0
0 1.5 W
0 0
1 0.25 0.5 0.5 0
2.25 WNW 0
0.25 0.25 0.5 0.5 0
0 1.5 NW 0
0 1.75 1.25 2
0 0
5 NNW 0
0 1.5 3.25 0
0 0
4.75 TOTAL 0
1.5 19 52.75 25.25 5.25 0
103.75 Page A6 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class D Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 0.25 5.5 4.25 3.25 1.75 0
15 NNE 0
0.75 11.75 34 21.25 1.75 0
69.5 NE 0
0 9.5 26.5 3.5 0
0 39.5 ENE 0
1 6.25 10.75 3.25 0
0 21.25 E
0 1.25 10.25 4.25 0
0 0
15.75 ESE 0
1 6.75 4
0 0.25 0
12 SE 0
0.75 5.25 3.25 2.5 0
0 11.75 SSE 0
0.75 9.25 16 3.25 2.25 0
31.5 S
0 0.5 8
13 3.75 0
0 25.25 SSW 0
0.5 8.75 18.5 0
0 0
27.75 SW 0
0.5 2.25 1.5 0.25 2.5 0
7 WSW 0
0.25 6.5 3.75 1
1.5 0
13 W
0 0.25 5
2 0.75 1
0 9
WNW 0
0.25 6
8.5 2.25 0
0 17 NW 0
0.25 7.75 0.25 0.75 0
0 9
NNW 0
0 7
12.25 1.75 0
0 21 TOTAL 0
8.25 115.75 162.75 47.5 11 0
345.25 Stabitity Class E Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0.5 1.75 13.5 5.75 0.25 0
0 21.75 NNE 0
0.5 15.5 28 8
0 0
52 NE 0
3 19.75 16.5 1.75 0
0 41.
ENE 0
1.25 16.25 5
0.
0 0
22.5 E
0 1
19.5 5.25 0.25 0
0 26 ESE 0
4.25 11.75 2.25 0
0.25 0.25 18.75 SE 0
3.75 13 3.25 1.25 1.25 0.75 23.25 SSE 0
4 16.25 9.25 6.75 2
0 38.25 S
0 2.5 29.25 21.25 4
0 0
57 SSW 0
2.5 17.25 5.75 1.25 0
0 26.75 SW 0
4.25 3.75 2
0.25 5.5 4
19.75 WSW 0
2.75 4.75 2.25 0.75 0
2 12.5 W
0 3
4.75 3.75 0
0.25 0.25 12 WNW 0
1.75 5.5 4.75 0
0 0
12 NW 0
4.25 5.75 0.5 0
0 0
10.5 NNW 0
1.25 17.5 10 0.25 0
0 29 TOTAL 0.5 41.75 214 125.5 24.75 9.25 7.25 423 Page A7 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 l
Stabitity Class F Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 1
8.75 1.5 0.5 0
0 11.75 NNE 0
1 6
3 1
0.25 0
11.25 NE 0
2.25 11 9.5 1.25 0
0 24 ENE 0
1 7
1.25 0
0 0
9.25 E
0 1.25 5.25 0.25 0
0 0
6.75 ESE 0
0.75 5.5 0.75 0
0 0
7 SE 0
0.75 8
0.5 1
0.5 0
10.75 SSE 0
0.5 8.75 4.25 3.5 0
0 17 S
0 1.75 14.75 3.5 2
0.25 0
22.25 SSW 0
2.5 6.25 0.5 0
0 0
9.25 SW 0
0.25 9.25 2.25 0
1.25 3
16 WSW 0
0.75 7.75 2.5 0.75 0
0 11.75 W
0 4
4.25 5.25 0
0 0
13.5 L
WNW 0
2.5 6.25 2.5 0
0 0
11.25 NW 0
2.25 5.25 0.5 0.25 0
0 8.25 NNW 0
1.75 14 1.25 0
0 0
17 TOTAL 0
24.25 128 39.25 10.25 2.25 3
207 Stabitity Class G Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL L
N 6.5 5.25 3
0.5 0
0 0
15.25 NNE 0
3 1.25 0.5 0.25 0
0
.5 NE 0
1.5 8
3.75 0
0 0
13.25 L
ENE 0
0.5 3.5 1
0.25 0
0 5.25 E
0 0.75 4.5 1.25 0
0 0
6.5 L
ESE 0
2 8
1 0.5 0
0 11.5 SE 0
1.75 12.75 2.5 0.75 0
0 17.75 SSE 0
3.5 18 25 8
0 0.25 54.75 S
0 4
21.5 13 0.5 0
0 39 SSW 0
7.25 7
3 0.25 0.5 0
18 SW 0
5 22.25 2
0 0
0 29.25 WSW 0
4.75 20.25 2.25 0
0 0
27.25 W
0 7
20.75 2.25 0
0 0
30 WNW 0
1.25 17.5 2
0 0
0 20.75 NW 0
3.5 13.25 0
0 0
0 16.75 NNW 0
3.75 9.25 0.25 0
0 0
13.25 TOTAL 6.5 54.75 190.75 60.25 10.5 0.5 0.25 323.5 Page A8 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 3Td QUARTER 2004 Total Hours Missing = 123.5 Stabitity Class A Total Hours = 2208 Wind Direction N
NNE NE ENE E
WNW NW NNW TOTAL CALM 0
0 0
0 0
0 0
0 0
0
.0
.. 0 0
0
- 0.
0 0
1-3 1.75 2.5 0.25 0.25 0.5 0.25 0.5 0
0.25 0.5 0.75 0.5 0.25 1
1.5 1.75 12.5 4-7 12.5 9.75 10.5 4.5 3.75 4
3 3
4.5 12.75 8.25 3.25 3
9.5 7.25 4.75 104.25 8-12 3.75 9.75 37.25 43.25 25.75 13.25 9.5 1
0.75 4
6 2.25 0.75 4.75 0
0.25 162.25 13-18 0
2.25 42.25 2
2.5 0
0 0
0 1.75 6.75 0.25 0
0 0
0 57.75 19-24 0
0 4.75 0
0 0
0 0
0 0
0 0
0 0
0 0
4.75
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 18 24.25 95 50 32.5 17.5 13 4
5.5 19 21.75 6.25 4
15.25 8.75 6.75 341.5 Stabitity Class B Wind Direction N
NNE NE ENE E
W WNW NW NNW TOTAL CALM 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1-3 0
0 0
0 0
0 0.25 0
0 0
0 0.25.
0 0.5.
0.5 0.75 2.25 4-7 3.75 5.75 1.5.
2.5 1
0.25 1
1.5 1.25 0.25 1.25 0
1.5 5.25 8.5 2
37.25 8-12 3.25 2.75 7.5 4
1.75 0.75 2.5 0.75 0
0.25 0
0.25 3
0 0
26.75 13-18 0
0 2.75 0
0 0
0.75 0
0 0
0 0
0 0
0 0
3.5 19-24 0
0 0
0 0
0 0
0 0
0 0 O 0
0 0
0 0
0
>24 0
0
- 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 TOTAL 7
8.5 11.75 6.5 2.75 1
4.5 2.25 1.25 0.25 1.5 0.25 1.75 8.75 9
2.75 69.75 Page A9 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class C Wind Direction N
NNE NE ENE E
WNW NW NNW TOTAL CALM 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1-3 0
0 0
0 0
0.25 0
0 0
-o 0.25 0
0 0.25 1
0.5 2.25 4-7 2.75 1
2.75 0
1 0.75 1.75 1.25 1
1.5 0.25 0.25 0.5 7
2.25 1.75 25.75 8-12 0.25 2
8 4.75 2
1.25 0.75 0.25 0.25
.0.25 0.5 0
0.75 1.5 0
0 22.5 13-18 0
0 2.25 0.25 0
0 0.75 1.75 0
0 0
0 0
0 0
5 19-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 3
3 13 5
3 2.25 3.25 3.25 1.25 1.75 1
0.25 1.25 8.75 3.25 2.25 55.5 Stabitity Class D Wind Direction N
NNE NE ENE
. E.
WNW NW NNW TOTAL CALM 0
0 0
0 0
0o 0
0 0
0 0
0 0
0 0
0 0
1-3 1.5 2
1 0.25 0
0.25 0.25 0
0 0.75 1.25 0.5 1
2 1.5 1.5 13.75 4-7 5.75 14.75 13 3.5 2
12.5 4.75 12.25 3.75 3.75 2.5 2.25 3.25 9
4.75 4.75 102.5 8-12 0.25 5
25.5 31 12.25 10.25 4.75 25.75 2
0.5 1.25 0
2.25 5
1.75 0.75 128.25 13-18 0
0 16.25 2
0 0.25 0.5 3.75 0
0 0
0 0
0
.0 0
22.75 19-24 0
0 0.25 0
0 0
0 0
0 0
0 0
0 0
0 0
0.25
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
- 0
.0 TOTAL 7.5 21.75 56 36.75 14.25 23.25 10.25 41.75 5.75 5
5 2.75 6.5 16 8
7 267.5 Page A1O of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class E Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 2
3.5 0
0 0
0 5.5 NNE 0
3.75 6
4.5 0.25 0
0 14.5 NE 0
1.75 8.25 44.75 15.5 0.25 0
70.5 ENE 0
1 10 16.25 0
0 0
27.25 E
0 1.75 13 14.75 1.25 0
0 30.75 ESE 0
3.5 32.25 12 1
0 0
48.75 SE 0
6 53 17.25 4
0 0
80.25 SSE 0
3.5 46 43.25 4.75 0
0 97.5 S
0 2.5 7
2 0.25 0
0 11.75 SSW 0
1.25 13.25 1.5 0
0 0
16 SW 0
0 6
0.5 0
0 0
6.5 WSW 0
0.75 2.75 0.25 0.25 0
0 4
W 0
0.25 9.75 1
0 0
0 11 WNW 0
0 6.25 0.25 0
0 0
6.5 NW 0
0.5 4
0 0
0 0
4.5 NNW 0
0.75 1.75 0
0 0
0 2.5 TOTAL 0
29.25 222.75 158.25 27.25 0.25 0
437.75 Stabitity Class F Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 5.5 3
0 0
0 0
8.5 NNE 0
2.75 8.5 1
0 0
0 12.25 NE 0
2 17.75 4.75 0
0 0
24.5 ENE 0
2 11.5 14.75 0
0 0
28.25 E
0 2
10.25 0
0 0
0 12.25 ESE 0
2.75 31.75 9.5 0.75 0
0 44.75 SE 0
2.75 62.5 23.75 4.5 0
0 93.5 SSE 0
2.25 40 11.75 6
1.5 0
61.5 S
0 2
4.25 0.75 0
0 0
7 SSW 0
1.75 2.25 0
0 0
0 4
SW 0
0.5 4.25 0
0 0
0 4.75 WSW 0
0 1.5 0
0 0
0 1.5 W
0 0
0.25 0
0 0
0 0.25 WNW 0
0.25 0
0 0
0 0
0.25 NW 0
0.75 0.5 0
0 0
0 1.25 NNW 0
0.75 0.5 0
0 0
0 1.25 TOTAL 0
28 198.75 66.25 11.25 1.5 0
305.75 Page All of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class G Wind Direction N
NNE NE ENE E
WNW NW NNW TOTAL CALM 0.5 0
0 0
0 0
0 0
0.25 0
0.25 0.25 0
0.5 4.
1.25 7
1-3 9.75 13.5 13.25 7
6 11.5 27 18.5 13 13 11 7.25 9
9.75 14.75 13.25 197.5 4-7 5
16 29.5 19.25 17.75 51.5 86 42.5 8
5 5
4.75 2.5 1.25 7
3.5 304.5 8-12 0
0.5 2
3.25 0.5 4
50 27.25 0
0.25 0
0 0
0 0O 0
87.75 13-18 0
0 0
0 0
0.
3.25 6.5 0
0 0
0 0
0 0
0 9.75 19-24 0.25 0
0 0
0 0
0 0
0 0
.0 0
0 0
0 0
0.25
>24 0
.0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 15.5 30 44.75 29.5 24.25 67 166.25 94.75 21.25 18.25 16.25 12.25 11.5 11.5 25.75 18 606.75 4th QUARTER 2004 Total Hours Missing = 37.00 Stabitity Class A Total Hours = 2208 Wind Direction N
NNE NE ENE E
WNW NW NNW TOTAL CALM 0
0 O0 0
0
.0 O'
0 0*
0 0.I 0
0 0
0 0
0 1-3 0.75 0
'0O 0.75 0.25 0.25 0
0 0.75 0.75 2.25 1.75 1.5 0.5 0
1 10.5 4-7 13 6
0.75 2.5 3.75 4.5 3
16.5 11.5 6.5 6.75 5.75 7
11.5 16 15.75 130.75 8-12 8.25 16.25 7.25 10 5
10 5.75 10.75 2
11.75 6.75 9.75 19.5 23.5 8.75 8.75 164 13-18 8.5 5.5 11 31.5 36.5 12.75 24.75 7.25 0.5 6
2.5 5.5 12.5 12.5 5
8.75 191 19-24 4.25 0
0.75 7.5 16.25 8.25 11 8.75 1.5 0
0.75 0
1.5 0.75 0.5 2
63.75
>24 0
0 0
0 0
0 0.75 6.75 0
0 0
0 0
0 0
0 7.5 TOTAL 34.75 27.75 19.75 52.25 61.75 35.75 45.25 50 16.25 25 19 22.75 42 48.75 30.25 36.25 567.5 Page A12 of A15
APPENDIX A Annual Radioactive Effluent Release Report 2004 L
Stabitity Class B I
Wind Direction L
CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 0
0.5 0.25 0.25 1.75 0
2.75 L
NNE 0
0 2.25 2.5 1.5 0
0 6.25 L
NE 0
0 1.75 0.75 0.75 0.75 0
4 ENE 0
0.25 1.75 4
1.5 0
0 7.5 E
0 0.25 0.25 0
5 4
0 9.5 L
ESE 0
0 0
1.75 0
0 0
1.75 SE 0
0.25 1
3.75 2.25 0
0 7.25 SSE 0
0 9.25 4.5 2.25 0
1 17 S
0 0
2.25 2.75 0.25 0
0 5.25 SSW 0
0 1.25 5.5 1.75 0
0 8.5 SW 0
0.25 1.25 4.5 1.75 0
0 7.75 L
WSW 0
0.25 1.75 4.25 0.25 0
0 6.5 W
0 0
2.5 7.75 4.75 0.25 0
15.25 WNW 0
0 2.25 8.75 2
0 0
13 NW 0
0.25 5
3.5 1.25 0
0 10 NNW 0
0 0.75 2
9.25 1.5 0
13.5 L
TOTAL 0
1.5 33.75 56.5 34.75 8.25 1
135.75 Stabitity Class C Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL L
N 0
0 0
1.25 1.25 0
0 2.5 NNE 0
0 1.5.
4.75 1
0 0
7.25 NE 0
0 1
1.75 0.5 0.5 0
3.75 L
ENE 0
0 1.25 3
2 0
0 6.25 E
0 0
0.5 5.75 4
1.5 0
11.75 ESE 0
0 0.25 1.5 1.25
.0 0
3
- SE 0
0 2
5.75 3.25 0
0 11 SSE 0
0 9.5 4.5 1.25 0
1.25 16.5 S.
0 0.25 1.25 3.25 0.5 0
0 5.25 L
SSSW 0
0 3.75 7
1.5 0
0 12.25 L SW 0
0 0.75 5
1.5 0
0 7.25 WSW 0
0.5 0.5 6
2.5 0.25 0
9.75 W
0 0
2.5 3.5 2.5 0
0 8.5 WNW 0
0 3.25 5.25 0.5 0
0 9
L NW 0
0.5 4
0.5 0.5 0.5 0
6 NNW 0
0.5 1
4.5 5.25 0
0 11.25
'TOTAL 0
1.75 33 63.25 29.25 2.75 1.25 131.25 Page A13 of Al5
APPENDIX A Annual Radioactive Effluent Release Report 2004 L
Stabitity Class D Wind Direction L
CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0 1.25 7.25 15.5 5
0 0
29 NNE 0
0.5 5
20.75 9.25 0
0 35.5 L
NE 0
0 12.25 1.75 2.5 1
0 17.5 ENE 0
0.25 10 11.75 7.75 0
0 29.75 E
0 1
1.75 9.25 11 1.75 0
24.75 ESE 0.25 1
4.75 7.25 5.25 1
0 19.5 SE 0
0.25 10.25 14 3.75 1.25 0
29.5 SSE 0
0.25 23.25 24.5 2.5 2.75 0.5 53.75 S
0 0.5 9.25 7.5 0
0 0
17.25 SSW 0
0 11 10.5 0.25 0
0 21.75 SW 0
0.25 12.25 8
9.75 0
0 30.25 t
WSW
.0 0
5 10.25 6
1 0
22.25 W
0 0.75 11.5 12.75 10.25 0.5 0
35.75 WNW 0
1 19.5 27.5 1
0 0
49 NW
- 0 0.25 13.75 15.25 9.75.
0 0
39 NNW 0
0.5 5.5 15.75 1.75 0
0 23.5 L
TOTAL 0.25 7.75 162.25 212.25 85.75 9.25 0.5 478 Stabitity Class E L
Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
0.25 2.5 6.5 7.25 0
0 0
16.5 NNE 0
1 4.25 15.75 1.5 0
0 22.5 NE 0
3.25 15.25 6
1 0
0 25.5 L
ENE 0
4.75 8.5 7.5 1
0 0
21.75 E
0.25 2
4.75 1.25 0.5 0
0 8.75 ESE 0
3.75 1.25 1
0 0
0 6
SE 0.25 1
22.25 10.5 0
0 0
34 SSE 0
2.75 25.75 21.5 3.5 2.25 0
55.75 S
0 1.75 6.5 9.5 1.5 2.5 0
21.75 L
SSW 0
5.75 27.5 11 1.5 0
0 45.75 SW 0
4.25 10.5 12 8.25 0.75 0
35.75 L
WSW 0
3.5 8.25 4
4.25 1.25 0
21.25 W
0 1.25 6
7 5.25 0
0 19.5 WNW 0
0.25 14.5 1.25 0
0 0
16 NW 0
- 3.
17.25 11.75 0
0 0
32 NNW 0
4.25 13.5 4.25 0
0 0
22 TOTAL 0.75 45 192.5 131.5 28.25 6.75 0
404.75 Page A14 of AlS
APPENDIX A Annual Radioactive Effluent Release Report 2004 Stabitity Class F Wind Direction CALM 1-3 4-7 8-12 13-18 19-i4
>24 TOTAL N
0 2.5 5
0.5 0
0 0
8 NNE 0
3 6.5 0.25 0
0 0
9.75 L
NE 0
1.25 8.5 1
0 0
0 10.75 ENE 0
2 6.5 0
0 0
0 8.5 E
0 2.25 4
0 0
0 0
6.25 L
ESE 0
2.75 0.75 0
0 0
0 3.5 SE 0
3.75 7.5 3.25 0
0 0
14.5 SSE 0
4.25 12.25 5.75 0
0 0
22.25 S
0 2.25 9
1 0
0 0
12.25 SSW 0
2.5 7.25 3.5 0
0 0
13.25 SW 0
0.75 10.25 1.25 2.25 0
0 14.5 L
WSW
- 0.
1.75 8.75 4
0 0
0 14.5 W
0 2
7 6.75 0
0 0
15.75 WNW 0
1.5 17 1
0 0
0 19.5 NW 0
- 6.
5.75 0
0 0
0 11.75 NNW 0
4.25 4.75 1.25 0
0 0
10.25 TOTAL 0
42.75 120.75 29.5 2.25 0
0 195.25 Stabitity Class G Wind Direction CALM 1-3 4-7 8-12 13-18 19-24
>24 TOTAL L
N 0
1 8.5 0
0 0
0 9.5 NNE 0
5 23 0
0 0
0 28 i
NE 0
2.5 30.75 0
0 0
0 33.25 L
ENE 0
2.25 21.25 0
0 0
0 23.5 E
0 1.25 1.25 0
0 0
0 2.5 ESE 0
1.5 1.5 0.75 0
0 0
3.75 L
SE 0
4 5.75 8.5 0
0 0
18.25 SSE 0
8 7.25 0.5 3.25 0
0 19 S
0 5.5 5
0 0
0 0
10.5 L
SSW 0
4.5 7.25 1.25 0
0 0
13 SW 0
5.75 8
3 0.75 0
0 17.5 WSW 0
5.75 11 0
0 0
0 16.75 W
0 6.25 11 0
0 0
0 17.25 WNW 0
10 4.75 0
0 0
0 14.75 NW 0
10 6.25 0
0 0
0 16.25.
NNW 0
7.25 6.25 1.25 0
0 0
14.75 TOTAL 0
80.5 158.75 15.25 4
0 0
258.5 Page AlS of Al5