MONTHYEARML23087A1012023-03-28028 March 2023 U.S. Geological Survey Triga Reactor, Annual Report Submittal in Accordance with Technical Specification 6.7.1 Rev. 00 ML21090A1912021-03-29029 March 2021 U.S. Geological Survey Triga Reactor, Annual Report Submittal in Accordance with Technical Specification 6.7.1 Rev. 00 ML20136A3362020-04-21021 April 2020 Us Dept. of Interior, Geological Survey (Usgs), Submittal of Corrected 2019 Annual Report ML20087H0192020-03-0202 March 2020 Us Dept of Interior, Geological Survey (USGS) - Submittal of 2019 Annual Report ML19044A3732019-01-31031 January 2019 Us Dept. of Interior, Geological Survey - Submittal of 2018 Annual Report ML18016A0512018-01-11011 January 2018 2017 Annual Report for the U.S. Geological Survey Triga Non-Power Reactor Facility ML17030A0362017-01-0909 January 2017 Us Dept. of the Interior, Geological Survey - Submittal of 2016 Annual Report ML16032A1662016-01-12012 January 2016 U.S. Geological Survey - Transmittal of 2015 Annual Report ML15043A0322015-02-0303 February 2015 Us Dept of Interior, Geological Survey - Submittal of 2014 Annual Report ML13037A1052013-01-24024 January 2013 U.S. Geological Survey Triga Non-Power Reactor Facility, 2012 Annual Report ML1104000232011-01-31031 January 2011 U. S. Geological Survey Triga Non-Power Reactor Annual Report - January 1, 2010 - December 31, 2010 ML1011701212010-04-19019 April 2010 Revision to the 2009 Annual Report ML1003303192010-01-25025 January 2010 U. S. Geological Survey Triga Non-Power Reactor Annual Report - January 1, 2009 - December 31, 2009 ML0902802312009-01-15015 January 2009 U.S. Geological Survey Triga Non-power Reactor Facility - 2008 Annual Report ML0802500232008-01-18018 January 2008 U.S. Geological Survey Trigra Reactor Annual Report for 2007 ML0510802622005-04-0808 April 2005 Letter Transmitting Replacement of the CY2003 Annual Report of the U.S. Geological Survey Triga non-power Reactor Facility ML0510504002005-04-0808 April 2005 U. S. Geological Survey Triga Reactor Annual Report January 1, 2003 - December 31, 2003 2023-03-28
[Table view] Category:Letter
MONTHYEARIR 05000274/20232022023-11-13013 November 2023 U.S. Geological - U.S. Nuclear Regulatory Commission Safety Inpsection Report No. 05000274/2023202 IR 05000274/20232032023-11-0909 November 2023 United States Geological Survey - U.S. Nuclear Regulatory Commission Security Inspection Report No. 05000274/2023203 (Public) IR 05000274/20232012023-02-27027 February 2023 United States Geological Survey - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000274/2023201 ML22026A4852022-03-0707 March 2022 Examination Confirmation Letter No. 50-274/OL-22-01, United States Department of Interior Geological Survey ML22053A1872022-02-22022 February 2022 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, Reactor Administrator Succession IR 05000274/20212022021-10-0101 October 2021 U.S. Geological U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000274/2021202 IR 05000274/20212032021-09-30030 September 2021 United States Geological Survey - Nuclear Regulatory Commission Security Inspection Report No. 05000274/2021203 IR 05000274/20202012021-04-21021 April 2021 United States Geological Survey, U.S. Nuclear Regulatory Commission Routine Inspection Report05000274/2020201 - Cover Letter and Enclosure ML21090A1912021-03-29029 March 2021 U.S. Geological Survey Triga Reactor, Annual Report Submittal in Accordance with Technical Specification 6.7.1 Rev. 00 ML21082A2822021-03-23023 March 2021 Letter to R. Horton, USGS Denver Federal Center, from B. Smith, NRC, NRC Office of Investigations Report No. 4-2019-014 - Release of OI Synopsis IR 05000274/20212012021-03-12012 March 2021 U.S. Geological Survey NRC Non-Routine Inspection Report 05000274/2021201 ML20314A2922020-12-0303 December 2020 USGS Issuance of Amendment No. 14 to Renewed Facility Operating License No. R-113 for the USGS Triga Research Reactor Increasing the Special Nuclear Material Possession Limit ML20336A0202020-12-0101 December 2020 U.S. Geological Survey Triga Reactor - License Amendment Request LAR 14, Supplemental Information Letter 04 Provided in Response to Phone Call with NRC Project Manager at 0854 Mst on 2020-11-30 ML20295A4242020-11-16016 November 2020 Notification of Mailing Address Change Regarding Submittal of Fingerprint Cards ML20310A3352020-11-0505 November 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, Updated Physical Security Plan, Rev. Xxi ML20310A2962020-11-0505 November 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, License Amendment Request LAR 14, Supplemental Information Letter 03 Provided in Resolution of Comments Presented by the State of Colorado During the Public M ML20296A4902020-10-22022 October 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, License Amendment Request LAR 14, Supplemental Information Letter 02 Provided in Response to Audit Visit on 2020-10-15 ML20318A0882020-10-22022 October 2020 U.S. Geological Survey Trig a Reactor, License Amendment Request LAR 14, Supplemental Information Letter 01 Provided in Response to Audit Visit on 2020-10-15 Purpose ML20295A5102020-10-21021 October 2020 U.S. Geological Survey - Regulatory Audit Report Proposed License Amended No. 14 to Increase the Special Nuclear Material Possession Limit ML20233A9962020-10-0909 October 2020 Us Geological Survey - Issuance of Amendment No. 13 to Renewed Facility Operating License No. R-113 to Amend Technical Specifications 3.1.3 and 4.1 for the Us Geological Survey Triga Research Reactor ML20279A5912020-10-0606 October 2020 U.S. Geological Survey - Regulatory Audit Proposed License Amendment No. 14 Tt Increase the Special Nuclear Material Possession Limit ML20279A3052020-10-0505 October 2020 U.S. Geological Survey - Acceptance of the Application for Proposed License Amendment No. 14 Increase in the Special Nuclear Nuclear Material Possession Limit ML20275A2672020-10-0101 October 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, License Amendment Request 2020-02, LAR 14, Rev. 00 ML20199M1672020-07-20020 July 2020 NRC Letter and SER Authorizing USGS to Use an Alternate A2 Value ML20183A1622020-07-0202 July 2020 U.S. Geological Survey - Acceptance of the Application for a License Amendment Exception to TS 3.1.3 and 4.1 to Allow Fewer than 110 Fuel Elements When Either Shutdown or Operating at a Power Level Not Greater than 5 Kilowatts ML20177A6102020-06-25025 June 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, License Amendment Request 2020-01, Supplemental Information Provided in Response to ML20176A465 ML20161A1272020-06-0404 June 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, License Amendment Request 2020-01, Revision 01 ML20134J1082020-05-13013 May 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, License Amendment Request 2020-01 ML20157A0752020-05-0707 May 2020 U.S. Geological Survey Triga Reactor, Docket Number 50-274, License Number R-113, Reactor Supervisor Appointment ML20136A3362020-04-21021 April 2020 Us Dept. of Interior, Geological Survey (Usgs), Submittal of Corrected 2019 Annual Report ML20134J1162020-04-10010 April 2020 7 of the Emergency Plan for the U.S. Geological Survey Triga Reactor (Gstr) Facility (License R-113, Docket 50-274) ML20087H0192020-03-0202 March 2020 Us Dept of Interior, Geological Survey (USGS) - Submittal of 2019 Annual Report ML19206A0622019-07-11011 July 2019 Us Dept of the Interior, Us Geological Survey Follow-Up on August 9, 2018 Letter Request for Approval for Use of Alternative A2 Value for Isotope Br-80m Under Appendix a to 10 CFR 71 ML19066A0542019-02-25025 February 2019 U.S. Dept of the Interior, Geological Survey, Reply to a Notice of Violation: EA-18-031 and EA-18-111 ML19044A3732019-01-31031 January 2019 Us Dept. of Interior, Geological Survey - Submittal of 2018 Annual Report ML18354B1702018-12-31031 December 2018 U.S Geological Survey-Notice of Violation and Proposed Imposition of Civil Penalty ML18324A5752018-11-16016 November 2018 United States Geological Survey (Usgs), Transfer of Reactor Supervisor Responsibilities. Position of Reactor Supervisor for Triga Facility Has Been Transferred from Mr. Brycen Roy to Mr. Christopher Farwell, Effective October 26, on Interim ML18324A5742018-11-16016 November 2018 United States Department of the Interior - Transfer of Reactor Administrative Responsibilities ML18325A1462018-11-0707 November 2018 U.S. Dept. of Interior, Geological Survey - Response to Apparent Violations Associated with NRC Investigation Reports 4-2017-027 and 4-2018-005; IA-18-038 IR 05000274/20182022018-08-15015 August 2018 United States Geological Survey - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-274/2018-202 ML18236A5512018-08-0909 August 2018 Request for Approval for Use of Alternative A2 Value for Isotope Br-80m Under Appendix a to 10 CFR 71 IR 05000274/20182032018-07-17017 July 2018 United States Geological Survey - U.S. Nuclear Regulatory Commission Security Inspection Report 05000274/2018203 ML18016A0512018-01-11011 January 2018 2017 Annual Report for the U.S. Geological Survey Triga Non-Power Reactor Facility ML17355A1472017-12-18018 December 2017 Establishing a Quality Assurance Program at the U.S. Geological Survey Triga Reactor Facility (License R-113, Docket 50-274) IR 05000274/20172012017-05-17017 May 2017 United States Geological Survey NRC Routine Inspection Report No. 50-274/2017-201 ML17074A6472017-04-19019 April 2017 United States Geological Survey TRIGA Reactor Closure of Confirmatory Action Letter No. NRR-03-005 on Site-Specific Compensatory Measures Implementation Plan ML17067A3942017-03-22022 March 2017 U.S. Geological Survey - Non-Power Reactor Closeout of Generic Letter 2016-01, "Monitoring of Neutron Absorbing Materials in Spent Fuel Pools," for the U.S. Geological Survey Training Reactor And Isotopes Production, General Atomics Research Reactor ML17046A3632017-02-17017 February 2017 Examination Report No. 50-274/OL-17-01, United States Geological Survey ML17030A0362017-01-0909 January 2017 Us Dept. of the Interior, Geological Survey - Submittal of 2016 Annual Report ML16326A1462016-12-0101 December 2016 Us Geological Survey - Amendment No. 11 to Indemnity Agreement Amendment No. D-10 2023-02-27
[Table view] |
Text
-a
- O;;USGS science fora changing world Departmrent of the Intcrior US Gcological SurvCy Box 25046 MS-974 Denvcr CO, 80225
.- *April 8, 2005 U.S. Nuclear Reguiatory C6mmission Document C6ntrol Desk' Washington DC 20555 .
Dear NRC staff:
The attached CY2003 annual report of the U.S. Geological Survey TRIGA non-power reactor facility is submitted as a replacement for the original submission of January.14, 2004. The original submission was missing the environmental monitoring information given on page 6 of this report.
The facility docket number is 50-274.
Sincerely, Timothy M. DeBey Reactor Supervisor Enclosure Copy to:
Al Adams, MS O-1 1-D-19 1
IL U.S. GEOLOGICAL SURVEY TRIGA REACTOR ANNUAL REPORT JANUARY 1, 2003 - DECEMBER 31, 2003 NRC LICENSE NO. R-1 13- DOCKET NO. 50-274
- 1. Personnel Changes: One personnel change occurred in CY 2003 when Paul Heifer, a SRO contractor, completed his contract.
II. Operating Experience The Geological Survey TRIGA Reactor (GSTR) was in normal operation for the year 2003. No major facility changes were made during the year.
A synopsis of irradiations performed during the year is given below, listed by the organization submitting the samples to the reactor staff:
Organization Number of Samples Geologic Division - INAA 909 Geologic Division - Geochronology 1352 Non-USGS affiliated 801 Total 3062 A. Thermal power calibrations were performed in May and November, with minor adjustments made to the instrumentation.
B. During the report period, 173 daily checklists and 12 monthly checklists were completed in compliance with technical specifications requirements for surveillance of the reactor facility.
C. Tours were provided to individuals and groups during the year for a total visitor count of approximately 400.
D. Three fuel movements were performed during the year for the purposes of increasing reactivity and performing the biennial control rod inspection.
2
Ill. Tabulation of Enermy Generated MWH operated Critical hours Pulses Jan 56.400 58.70 0 Feb 27.400 28.22 0 Mar 61.645 63.02 0 Apr 62.519 64.63 0 May 82.055 87.83 0 June 45.116 46.22 0 July 32.143 35.13 0 Aug 43.285 44.97 0 Sept 106.917 109.50 0 Oct 73.667 79.10 0 Nov 26.800 29.50 0 Dec 51.201 53.47 0 Totals 669.148 699.76 0 IV. Unscheduled Shutdowns Number Date Cause :
993 5/1/03 DAC DIS064 Timeout scram (cause unknown) 994 8/8/03 DAC DIS064 Timeout scram (cause unknown) 995 10/30/03 NP1 000 high power scram while adjusting rod positions (operator in training) 996 12/2/03 NPP 1000 high power scram while increasing power in automatic control.
V. Maior Maintenance Operations
- 1. The primary coolant ion exchange resin was replaced on July 9, 2003.
- 2. The GM detector in the continuous air monitor was replaced on July 30, 2003, and the instrument was recalibrated.
- 3. A new conductivity system (Foxboro) was installed on October 16, 2003.
3
tS
- 4. The Campbelling unit was replaced in the NM1000 wide range power instrument on November 3, 2003. The instrument was calibrated and functionally verified to be operating properly after the replacement.
VI. Summary of 10 CFR 50.59 changes No 50.59 changes were made during this year.
VII. Radioactivitv Releases A. Listed below are the total amounts of radioactive gaseous effluent released to the environment beyond the effective control of the reactor facility.
Table 1. Gaseous Effluents Released to the Environment Month Argon-41License Tryiur. (ECTo ICFR2O Allowable Allowable (curies) (Ci) (R-1 13) (mCi) * (mCi)
January 0.192 5.833 0.184- 124 February 0.016 5.833 0.070' 124 March 0.148 5.833 0.083 124 April 0.164 5.833 0.060 124 May 0.179 5.833 0.146 124 June 0.210 5.833 0.080 124 July 0.164 5.833 0.100 124 August 0.150 5.833 0.075 124 September 0.403 5.833 0.075 124 October 0.338 5.833 0.157 124 November 0.135 5.833 0.059 124 December 0.190 5.833 0.078 124 Total 2.289 70.00 1.167 1488 j% of Allowable -3.27% ___ __ 0.08%
- Note: The tritium concentrations are estimates based on the amount of water lost by evaporation from the reactor multiplied by the concentration of tritium as HTO. Tritium sample analyses are being performed by Hazen Research.
B. One 55-gallon drum of low-level radioactive solid waste was shipped for burial in Washington State during the year.
Note: The principal radioactive waste generated at the reactor facility is the demineralizer resin. Used resin with small quantities of rinse water was de-watered by evaporation and placed in a 55-gallon drum.
4
i VIII. Radiation Monitoring Our program to monitor and control radiation exposures included the four major elements below during the operating year.
- 1. Fifteen gamma-sensitive area monitors are located throughout the Nuclear Science Building. A remote readout panel is located in the reactor health physics office. High alarm set points range from 2 mR/hr to 50 mR/hr. High level alarms are very infrequent and due to sample movements.
- 2. One Continuous Air Monitor (CAM) samples the air in the reactor bay. An equilibrium concentration of about 1 x 10a 1iCi/ml present for two minutes will result in an increase of 400 cpm above background. There are two alarm setpoints. A low-level alarm is set at 3000 cpm and the high level alarm is set at 10000 cpm.
Reactor bay air is sampled during all reactor operations. The fixed particulate air filter is changed each week and counted on a HPGE gamma spectrometer counting system' The charcoal filter, fitted behind the air filter, is also changed and counted weekly. In all instances, sample data were less than airbome concentration value (10 CFR Part 20, Appendix B, Table 2) for all particulate radioisotopes produced by the reactor.
- 3. Contamination wipe surveys and radiation surveys with portable survey instruments are performed at least once a month. All portable instruments are calibrated with a 3-Curie (initial activity) Cs-1 37 source traceable to NBS, and wipes are counted on a Gamma Products G5000 low level counting system. Six contaminated areas were noted during routine wipe surveys with contamination above 30 pCi/100 cm2 beta. The three highest had beta activity of 239 pCi/1 00 cm2 and two had 40 pCiI 00 cm2 . Soap and water were used to remove the contamination. All other areas were less than 30 pCi/1 00 cm2 beta and 15 pCi/100 cm2 alpha. The roof area over the reactor tank is roped off and posted as a radiation area (averaging 2.5 mRlhr) during 1 MW operations.
- 4. Personnel, X and gamma, beta and neutron film badges are assigned to all permanent occupants of the Nuclear Science Building. LiF TLD dosimeters were used at four outdoor environmental stations. Reactor facility visitors are issued self-reading dosimeters. Reactor staff personnel are issued albedo neutron badges.
5
iI Table 2. Personnel Monitoring Results ( 121102 - 11/30103)
Deep Dose Shallow Dose Equivalent Equivalent Name Whole Body (Rem) Whole Body (Rem) Extremity (Rem)
Aakhus-Witt A. 0.010 0.016 0.081 Aspey, N. 0.0 0.0 Not monitored DeBey, T 0.052 0.056 0.093 Helfer, P 0.0 0.0 0.0 Hutchings, R. 0.0 0.0 Not monitored Liles, D 0.069 0.070 0.177 Perryman, R 0.050 0.056 0.252 Note: Personnel dosimetry results from December 2003 are not available at this time.
Reactor visitors and occasional experimenters wore pocket dosimeters that resulted in no individual reading that was greater than one (1) mrem.
Table 3. Environmental Dose Results Location Dose Dose Dose Dose Total Jan-Mar Apr-June July-Sept. Oct.- Dec.
(_RAD ) (RAD) (RAD D)( (RAD)
Exhaust 0.0 0.0047 0.0001 0.0011 0.0059 Stack Cooling 0.0 0.0 0.0 0.0 0.0 Tower Fence West Vehicle 0.0064 0.0026 0.0031 0.0036 0.0157 Gate West Room 0.0 0.0020 0.0 0.0. 0.002 151 Gate Southwest 0.0 0.0 0.0108 0.0 0.0108 Light Pole
,Control - 0.0312 -0.0277 0.0266 0.0302 0.1157 (background)
Southeast - 0.0000 0.0 0.0 0.0 0.0 Light Pole I I Note: Above totals have the background subtracted (see control). Control is an average.
X. Environmental Monitoring There have been no uncontrolled radioactivity releases from the reactor to the present date. Thus, the data on file from past years to the present are considered to be background information.
6