LCO Applicability 3.0 LCO 3.0.4 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:
- a.
When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time;
- b.
After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate; exceptions to this Specification are stated in the individual Specifications, or
- c.
When an allowance is stated in the individual value, parameter, or other Specification.
This Specification shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.
LCO 3.0.5 Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment.
This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.
(continued)
INDIAN POINT 3
- 3. 0 -
2
.Amendment 226
SR Applicability 3.0 3.0 SR APPLICABILITY (continued)
SR 3.0.4' Entry into a MODE or other specified condition in the Applicability of an LCO shall only be made when the LCO's Surveillances have been met within their specified Frequency, except as provided by SR 3.0.3.
When an LCO is not met due to Surveillances not having been met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with LCO 3.0.4.
This provision shall not prevent entry into MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.
INDIAN POINT 3
- 3. 0 -
5 Amendment 226
PAM Instrumentation 3.3.3 3.3 INSTRUMENTATION 3.3.3 Post Accident Monitoring (PAM) Instrumentation LCO 3.3.3 APPLICABILITY:
The PAM instrumentation for each Function in Table 3.3.3-1 shall be OPERABLE.
MODES 1, 2, and 3.
ACTIONS S
C-eNOTE i
do Separate Condition entry is allowe~d for each Function.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more Functions A.1 Restore one channel to 30 days with one required channels OPERABLE status.
B.
Required Action and B.1 Initiate action in Immediately associated Completion accordance with Time of Condition A not Specification 5.6.7 met.
(continued)
INDIAN POINT 3 3.3.3-1 Amendment 226
I-Remote Shutdown 3.3.4 3.3 INSTRUMENTATION 3.3.4 Remote Shutdown LCO 3.3.4 The Remote Shutdown Functions shall be OPERABLE.
APPLICABILITY:
MODES 1, 2, and 3.
ACTIONS NOTE Separate Condition entry is allowed for each Function.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more required A.1 Restore required Function 30 days Functions inoperable.
to OPERABLE status.
B.
Required Action and B.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.
AND B.2 Be in MODE 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> INDIAN POINT 3 3.3.4-1 Amendment 226
I r
Pressurizer PORVs 3.4.11 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.11 Pressurizer Power Operated Relief Valves (PORVs)
LCO 3.4.11 Each PORV and associated block valve shall be OPERABLE.
APPLICABILITY: MODES 1, 2, and 3.
ACTIONS NOTE -------------------
Separate Condition entry is allowed for each PORV.
CONDITION REQUIRED ACTION COMPLETION TIME A. One or more PORVs A.1 Close and maintain 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable and power to capable of being associated block manually cycled.
valve.
B. One PORV inoperable B.1 Close associated 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and not capable of block valve.
being manually cycled.
AND B.2 Remove power from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> associated block valve.
AND B.3 Restore PORV to 7 days OPERABLE status.
(continued)
INDIAN POINT 3 3.4. 11-1 Amendment 226
e LTOP 3.4.12 ACTIONS
_----------------- NOTE -------------
LCO 3.0.4.b is not applicable when entering MODE 4.
CONDITION REQUIRED ACTION COMPLETION TIME A. One or more HHSI pump(s) capable of injecting into the RCS.
A.1 Initiate action to verify no HHSI pumps are capable of injecting into the RCS.
OR A.2.1 Verify RCS is vented with opening 2 2.00 square inches.
AND A.2.2 Verify pressurizer level is
- 0%.
AND A.2.3 Verify no more than two HHSI pumps are capable of injecting into the RCS.
Immediately Immediately Immediately AND Once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Immediately AND Once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Immediately Immediately AND Once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> OR A.3.1 Verify RCS is vented with opening greater than or equal to one pressurizer code safety valve flange.
AND A.3.2 Verify no more than two HHSI pumps are capable of injecting into the RCS (continued)
INDIAN POINT 3 3.4.12-2 Amendment 226
RCS Leakage Detection Instrumentation 3.4.15 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.15 RCS Leakage Detection Instrumentation LCO 3.4.15 The following RCS leakage detection instrumentation shall be OPERABLE:
- a.
One containment sump discharge flow monitor;
- b.
One containment atmosphere radioactivity monitor (gaseous or particulate); and
- c.
One containment fan cooler unit condensate measuring system.
APPLICABILITY: MODES 1, 2, 3, and 4.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Required A.1 Perform SR Once per 24 containment sump 3.4.13.1.
hours flow monitor inoperable.
AND A.2 Restore required 30 days containment sump monitor to OPERABLE status.
(continued)
INDIAN POINT 3 3.4.15-1 Amendment 226
I RCS Specific Activity 3.4.16 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.16 RCS Specific Activity LCO 3.4.16 The specific activity of the reactor coolant shall be within limits.
APPLICABILITY: MODES 1 and 2, MODE 3 with RCS loop average temperature (Tvg) 2 5000F.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
DOSE EQUIVALENT
NOTE ---------
I-131 > 1.0 Ci/gm.
LCO 3.0.4.c is applicable A.1 Verify DOSE Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> EQUIVALENT I-131 within the acceptable region of Figure 3.4.16-1.
AND A.2 Restore DOSE 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> EQUIVALENT I-131 to within limit.
B. Gross specific B.1 Be in MODE 3 with 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> activity of the Tavg < 500 0F.
reactor coolant not within limit of SR 3.4.16.1.
(continued)
INDIAN POINT 3
- 3. 4.16-1 Amendment 226
I r
ECCS -
Shutdown 3.5.3 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) 3.5.3 ECCS-Shutdown LCO 3.5.3 One ECCS residual heat removal (RHR) subsystem and one ECCS recirculation subsystem shall be OPERABLE.
NOTE-----------------------
An RHR train may be considered OPERABLE during alignment and operation for decay heat removal, and during valve, if capable of being manually realigned to the ECCS mode of operation.
APPLICABILITY: MODE 4.
ACTIONS
NOTE-----------------------
LCO 3.0.4.b is not applicable to the ECCS residual heat removal and ECCS recirculation subsystems.
CONDITION REQUIRED ACTION COMPLETION TIME A. Required ECCS A.1 Initiate action to Immediately residual heat restore required removal (RHR)
ECCS RHR subsystem subsystem to OPERABLE status.
B. Required ECCS B.1 Restore required 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Recirculation ECCS recirculation subsystem subsystem to inoperable.
OPERABLE status.
C. Required Action and C.1 Be in MODE 5.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> associated Completion Time of Condition B not met.
INDIAN POINT 3 3.5. 3-1 Amendment 226
4 e
Hydrogen Recombiners 3.6.8 3.6 CONTAINMENT SYSTEMS 3.6.8 Hydrogen Recombiners LCO 3.6.8 Two hydrogen recombiners shall be OPERABLE.
APPLICABILITY: MODES 1 and 2.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One hydrogen A.1 Restore hydrogen 30 days recombiner recombiner to inoperable.
OPERABLE status.
B. Required Action B.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and associated Completion Time not met.
INDIAN POINT 3
- 3. 6.8-1 Amendment 226
i ADVs 3.7.4 3.7 PLANT SYSTEMS 3.7.4 Atmospheric Dump Valves (ADVs)
LCO 3.7.4 APPLICABILITY:
Three ADV lines shall be OPERABLE.
MODES 1, 2, and 3, MODE 4 when steam generator is relied upon for heat removal.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME N
A. One required ADV A.1 Restore required 7 days line inoperable.
ADV line to OPERABLE status.
B. Two or more B.1 Restore all but 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> required ADV lines one ADV line to inoperable.
OPERABLE status.
C. Required Action and C.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not AND met.
C.2 Be in MODE 4 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> without reliance upon steam generator for heat removal.
INDIAN POINT 3
- 3. 7.4-1 Amendment 226
I r
AEW System 3.7.5 3.7 PLANT SYSTEMS 3.7.5 Auxiliary Feedwater (AFW) System LCO 3.7.5 Three AFW trains shall be OPERABLE.
NOTE----------------------
Only one AFW train, which includes a motor driven pump capable of supporting the credited steam generator(s), is required to be OPERABLE in MODE 4.
APPLICABILITY: MODES 1, 2, and 3, MODE 4 when steam generator is relied upon for heat removal.
ACTIONS
NOTE----------------
LCO 3.0.4.b is not applicable.
CONDITION REQUIRED ACTION COMPLETION TIME A. One steam supply to A.1 Restore steam 7 days turbine driven AFW supply to OPERABLE pump inoperable.
status.
AND 10 days from discovery of failure to meet the LCO B. One AFW train B.1 Restore AFW train 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> inoperable in MODE to OPERABLE 1,
2 or 3 for status.
AND reasons other than Condition A.
10 days from discovery of failure to meet the LCO (continued)
INDIAN POINT 3
- 3. 7.5-1 Amendment 226
AC Sources -
Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS 3.8.1 AC Sources -
Operating LCO 3.8.1 The following AC electrical sources shall be OPERABLE:
- a.
Two qualified circuits between the offsite transmission network and the onsite Electrical Power Distribution System; and
- b.
Three diesel generators (DGs) (31, 32 and 33) capable of supplying the onsite power distribution subsystem (s)
Note-----------------------
The 138 kV circuit is considered inoperable whenever the automatic transfer function for the 6.9 kV buses is disabled.
APPLICABILITY:
MODES 1, 2, 3, and 4.
ACTIONS
Note-------------------------------
The LCO 3.0.4.b is not applicable to DGs or the 138kV offsite circuit.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One offsite A.1 Perform SR 3.8.1.1 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> circuit for OPERABLE offsite inoperable.
circuit.
AND AND Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter (continued)
INDIAN POINT 3
- 3. 8.1 -
1 Amendment 226