LCO Applicability 3.0 3.0 LCO APPLICABILITY (continued)

LCO 3.0.4 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:

a.

\\When the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time;

b.

After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate; exceptions to this Specification are stated in the individual Specifications, or

c.

When an allowance is stated in the individual value, parameter, or other Specification.

This Specification shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

I LCO 3.0.5 Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.

LCO 3.0.6 When a supported system LCO is not met solely due to a support system LCO not being met, the Conditions and Required Actions associated with this supported system are not required to be entered.

Only the support system LCO ACTIONS are required to be entered.

Prairie Island Units I and 2 Unit I - Amendment No. 4I5&, 167 Unit 2 - Amendment No. l449, 1571 3.0-2

LCO Applicability 3.0 3.0 LCO APPLICABILITY LCO 3.0.6 (continued)

This is an exception to LCO 3.0.2 for the supported system. In this event, an evaluation shall be performed in accordance with Specification 5.5.13, "Safety Function Determination Program (SFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered.

When a support system's Required Action directs a supported system to be declared inoperable or directs entry into Conditions and Required Actions for a supported system, the applicable Conditions and Required Actions shall be entered in accordance with LCO 3.0.2.

LCO 3.0.7 Test Exception LCOs 3.1.8 and 3.4.18 allow specified Technical Specification (TS) requirements to be changed to permit performance of special tests and operations. Unless otherwise specified, all other TS requirements remain unchanged. Compliance with Test Exception LCOs is optional. When a Test Exception LCO is desired to be met but is not met, the ACTIONS of the Test Exception LCO shall be met. When a Test Exception LCO is not desired to be met, entry into a MODE or other specified condition in the Applicability shall be made in accordance with the other applicable Specifications.

LCO 3.0.8 When a Technical Specification supported system LCO is not met solely due to the inoperability of a non-Technical Specification support system listed below, the Technical Specification supported system LCO is considered to be met unless the associated delay time of the non-Technical Specification support system has expired. This is an exception to LCO 3.0.2 for the Technical Specification. Upon expiration of the non-Technical Specification support system delay time, the Technical Specification supported system shall be declared inoperable and the applicable Conditions and Required Actions for the Technical Specifications supported system shall be entered in accordance with LCO 3.0.2.

Prairie Island Units I and 2 Unit I - Amendment No. 4--59, 167 Unit 2 - Amendment No. 149, 1571 3.0-3

LCO Applicability 3.0 3.0 LCO APPLICABILITY LCO 3.0.8 Non-Technical Specification Support System Delav Time (continued)

Snubbers 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> LCO 3.0.9 Unless specifically noted, all the information provided in the LCO including the associated ACTION requirements shall apply to each unit individually. Whenever certain portions of a specification refer to systems, components, operating parameters, setpoints, etc., which are different for each unit, this will be identified in parentheses or notes or in the Applicability section as appropriate.

Prairie Island Units 1 and 2 Unit I - Amendment No. 45-,

167 Unit 2 - Amendment No. 149, 1571 3.0-4

LCO Applicability 3.0 3.0 SR APPLICABILITY (continued)

SR 3.0.3 If it is discovered that a Surveillance was not performed within its specified Frequency, then compliance with the requirement to declare the LCO not met may be delayed, from the time of discovery, up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or tip to the limit of the specified Frequency, whichever is greater. This delay period is permitted to allow performance of the Surveillance. A risk evaluation shall be performed for any Surveillance delayed greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and the risk impact shall be managed.

If the Surveillance is not performed within the delay period, the LCO must immediately be declared not met, and the applicable Condition(s) must be entered.

When the Surveillance is performed within the delay period and the Surveillance is not met, the LCO must immediately be declared not met, and the applicable Condition(s) must be entered.

SR 3.0.4 Entry into a MODE or other specified condition in the Applicability of an LCO shall only be made when the LCO's Surveillances have been met within their specified Frequency, except as provided by SR 3.0.3. When an LCO is not met due to Surveillances not having been met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with LCO 3.0.4.

This provision shall not prevent entry into MODEs or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the unit.

Prairie Island Unit 1 - Amendment No. 4-1, 167 Units I and 2 3.0-6 Unit 2 - Amendment No. 449, 157 l

ITC 3.1.3 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. --

NOTE ----------


NOTE -----------------

Required Action C. l LCO 3.0.4.c is applicable.

must be completed whenever Condition C is entered.

C. 1 Re-evaluate core design and Once prior to safety analysis, and reaching the determine that the reactor equivalent of an Projected end of cycle core is acceptable for equilibrium RTP (EOC) ITC not within continued operation.

all rods out boron lower limit.

concentration of 300 ppm D. Required Action and D. I Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time of Condition C not met.

I Prairie Island Units 1 and 2 Unit I - Amendment No. 45-,

167 Unit 2 - Amendment No. 449, 1571 3.1.3-2

EM Instrumentation

-.3.3 3.3 INSTRUMENTATION 3.3.3 Event Monitoring (EM) Instrumentation LCO 3.3.3 The EM instrumentation for each Function in Table 3.3.3-1 shall be OPERABLE.

APPLICABILITY:

MODES 1 and 2.

ACTIONS


NOTE---------------------------------------------------

Separate Condition entry is allowed for each Function.

CONDITION REQUIRED ACTION COMPLETION TIME A. ----------- NOTE-

.1 Restore required channel 30 days Not applicable to core to OPERABLE status.

exit temperature Function.

One or more Functions with one required channel inoperable.

Prairie Island Units I and 2 Unit 1 - Amendment No. 8, 167 Unit 2 - Amendment No. 4149, 157 3.3.3-1

Pressurizer PORVs 3.4.11 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.11 Pressurizer Power Operated Relief Valves (PORVs)

LCO 3.4.11 Each PORV and associated block valve shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS


NOTE--------------------------------

Separate Condition entry is allowed for each PORV and each block valve.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or both PORVs A.1 Close and maintain power 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable and capable to associated block of being manually valve(s).

cycled.

Prairie Island Units I and 2 Unit I - Amendment No. 4-59, 167 Unit 2 - Amendment No. 449, 157 3.4.11-1

LTOP - RCSCLT > SI Pump Disable Temperature 3.4.12 ACTIONS NOTE ---------------------------------------------------

LCO 3.0.4.b is not applicable when entering MODE 4.

CONDITION REQUIRED ACTION COMPLETION TIME A. Two SI pumps capable of A.!

Initiate action to assure a Immediately injecting into the RCS.

maximum of one SI pump is capable of injecting into the RCS.

B. An ECCS accumulator B. l Isolate affected ECCS 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> not isolated when the accumulator.

ECCS accumulator pressure is greater than or equal to the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.

Prairie Island Units 1 and 2 Unit 1 - Amendment No. 45, 167 Unit 2 - Amendment No. 4-49, 157 1 3.4.12-2

LTOP - RCSCLT > SI Pump Disable Temperature 3.4.12 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. Required Action and C.l Increase RCS cold leg 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion temperature to > the OPPS Time of Condition B not enable temperature met.

specified in the PTLR.

OR C.2 Depressurize affected 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> ECCS accumulator to less than the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.

D. One required PORV D. 1 Restore required PORV to 7 days inoperable.

OPERABLE status.

E. Two PORVs inoperable.

E.1 Be in MODE 5.

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> OR AND Required Action and E.2 Depressurize RCS and 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion establish RCS vent of > 3 Time of Condition A, C, square inches.

or D not met.

OR OPPS inoperable.

Prairie Island Units 1 and 2 Unit 1 - Amendment No. 4I5, 167l Unit 2 - Amendment No. -49, 157 1 3.4.12-3

LTOP - RCSCLT

  • SI Pump Disable Temperature 3.4.13 ACTIONS

NOTE -------------------------------------------------

LCO 3.0.4.b is not applicable when entering MODE 4.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or both SI pump(s)

A.1 Initiate action to verify no SI Immediately capable of injecting into pump is capable of injecting the RCS.

into the RCS.

B. An ECCS accumulator B.1 Isolate affected ECCS 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> not isolated when the accumulator.

ECCS accumulator pressure is greater than or equal to the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.

C. Required Action and C.1 Increase RCS cold leg 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion temperature to > the OPPS Time of Condition B not enable temperature specified met.

in the PTLR.

OR C.2 Depressurize affected ECCS 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> accumulator to less than the maximum RCS pressure for existing cold leg temperature allowed in the PTLR.

Prairie Island Units 1 and 2 Unit I - Amendment No. 4-5-8, 167 Unit 2 - Amendment No. 449, 1571 3.4. 13-2

RCS Leakage Detection Instrumentation 3.4.16 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.16 RCS Leakage Detection Instnimentation LCO 3.4.16 The following RCS leakage detection instrumentation shall be OPERABLE:

a.

One containment sump A monitor (pump run time instrumentation);

and

b.

One containment radionuclide monitor.

APPLICABILITY.

MODES 1, 2, 3, and 4.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Required containment A.1


NOTE ------------

sump monitor inoperable.

Not required until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after establishment of steady state operation.

Perform SR 3.4.14.1.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> AND I

Prairie Island Units I and 2 3.4.16-1 Unit 1 - Amendment No. 4-5-8, 167 Unit 2 - Amendment No. 4-49, 1571

RCS Specific Activity

.3.4.17 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.17 RCS Specific Activity LCO 3.4.17 APPLICABILITY:

The specific activity of the reactor coolant shall be within limits.

MODES I and 2, MODE 3 with RCS average temperature (Tavg) > 5000F.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

DOSE EQUIVALENT


NOTE---------------

I-131 > 1.0 ptCi/gm.

LCO 3.0.4.c is applicable.

A. 1 Verify DOSE Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> EQUIVALENT I-13 1 within the acceptable region of Figure 3.4.17-1.

AND A.2 Restore DOSE 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> EQUIVALENT I-131 to within limit.

I I

Prairie Island Units 1 and 2 Unit I - Amendment No. 4-5, 167 Unit 2 - Amendment No. 449, 157 3.4.17-1

ECCS - Shutdown 3.5.3 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) 3.5.3 ECCS - Shutdown LCO 3.5.3 One ECCS train shall be OPERABLE.

An RHR train may be considered OPERABLE during alignment and operation for decay heat removal, if capable of being manually realigned to the ECCS mode of operation.

APPLICABILITY:

MODE 4 when both RCS cold leg temperatures are > SI pump disable temperature specified in PTLR.

ACTIONS


NOTE------------------------------------------------------

LCO 3.0.4.b is not applicable to ECCS safety injection (SI) subsystem.

CONDITION REQUIRED ACTION COMPLETION TIME A.

Required ECCS residual A. 1 Initiate action to restore Immediately heat removal (RHR) required ECCS RHR subsystem inoperable.

subsystem to OPERABLE status.

B.

Required ECCS safety B.l Restore required ECCS SI 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> injection (SI) subsystem subsystem to OPERABLE inoperable.

status.

Prairie Island Units I and 2 Unit 1 - Amendment No. 4-5, 167 Unit 2 - Amendment No. -49, 157 3.5.3-1

ECCS - Shutdown 3.5.3)

ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C.

Required Action and C.1 Be in MODE 5.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> associated Completion Time of Condition B not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.5.3.1 The following SRs are applicable for all equipment In accordance required to be OPERABLE:

with applicable SRs SR 3.5.2.1 SR 3.5.2.7 SR 3.5.2.3 SR 3.5.2.8 SR 3.5.2.4 Prairie Island Units I and 2 Unit I - Amendment No. -148, 167 Unit 2 - Amendment No. 449, 157 l 3.5.3-2

MFRVs and MFRV Bypass Valves 3.7.3 3.7 PLANT SYSTEMS 3.7.3 Main Feedwater Regulation Valves (MFRVs) and MFRV Bypass Valves LCO 3.7.3 Two MFRVs and two MFRV bypass valves shall be OPERABLE.

APPLICABILHIY:

MODES 1, 2, and 3.

ACTIONS


NOT]

Separate Condition entry is allowed for each v Lc-I CONDITION REQUIRED ACTION COMPLETION TIME A.

One or both MFRVs A. 1 Close and place in manual 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> inoperable.

or isolate flow through MFRV(s).

AND A.2 Verify MFRV(s) closed and Once per 7 days in manual or flow through MFRV(s) isolated.

Prairie Island Units I and 2 Unit 1 - Amendment No. 4-5lS, 167 Unit 2 - Amendment No. 4-49, 157 3.7.3-1

SG PORVs 3.7.4 3.7 PLANT SYSTEMS 3.7.4 Steam Generator (SG) Power Operated Relief Valves (PORVs)

LCO 3.7.4 Two SG PORV lines shall be OPERABLE.

APPLICABILflY:

MODES 1, 2, and 3, MODE 4 when steam generator is relied upon for heat removal.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One SG PORV line A.1 Restore SG PORV line to 7 days inoperable.

OPERABLE status.

B. Two SG PORV lines B.I Restore one SG PORV line 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable.

to OPERABLE status.

C. Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND C.2 Be in MODE 4 without 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> reliance upon steam generator for heat removal.

I Prairie Island Units I and 2 Unit I - Amendment No. 4I5-9, 167 Unit 2 - Amendment No. 4l49, 157 3.7.4-1

AFW System 3.7.5 ACTIONS


NOTE ------------------

LCO 3.0.4.b is not applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A. One steam supply to A. 1 Restore affected equipment 7 days turbine driven AFW to OPERABLE status.

pump inoperable.

AND OR 10 days from discovery of


NOTE -----------

failure to meet the Only applicable if MODE LCO 2 has not been entered following refueling.

One turbine driven AFW pump inoperable in MODE 3 following refueling.

B. One AFW train B. I Restore AFW train to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> inoperable in MODE 1, 2, OPERABLE status.

or 3 for reasons other AND than Condition A.

10 days from discovery of failure to meet the LCO Prairie Island Units I and 2 Unit 1 - Amendment No. 4-54, 167 Unit 2 - Amendment No. 449, 157 3.7.5-2

AC Sources-Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS 3.8.1 AC Sources-Operating LCO 3.8.1 The following AC electrical sources shall be OPERABLE:

a. Two paths between the offsite transmission grid and the onsite 4 kV Safeguards Distribution System; and
b. Two diesel generators (DGs) capable of supplying the onsite 4 kV Safeguards Distribution System.

APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTIONS

-NOTE --------------------------------------------------

LCO 3.0.4.b is not applicable to DGs.

CONDITION REQUIRED ACTION COMPLETION TIME A. One path inoperable.

A.l Perform SR 3.8. 1.1 for the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> OPERABLE path.

AND Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter AND Prairie Island Units l and 2 Unit I - Amendment No. 458., 167 Unit 2 - Amendment No. 4-49, 157 3.8.1-1

AC Sources-Operating 3.8.1 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. (continued)

A.2 Restore path to 7 days OPERABLE status.

AND 14 days from discovery of failure to meet LCO B. One DG inoperable.

B. 1 Perform SR 3.8. 1.1 for the I hour paths.

AND Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter AND B.2 Declare required feature(s) 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> from supported by the discovery of inoperable DG inoperable Condition B when its required concurrent with redundant feature(s) is inoperability of inoperable.

redundant required feature(s)

AND Prairie Island Units I and 2 Unit I - Amendment No. 4-5-,

167 Unit 2 - Amendment No. 4-19, 157 l 3.8.1-2

AC Sources-Operating 3.8.1 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME B. (continued)

B.3.1 Determine OPERABLE DG is not inoperable due to common cause failure.

OR B.3.2 Perform SR 3.8.1.2 for OPERABLE DG.

AND B.4 Restore DG to OPERABLE status.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 24 hours 7 days AND 14 days from discovery of failure to meet LCO Prairie Island Units 1 and 2 Unit 1 - Amendment No. l-&58, 167 Unit 2 - Amendment No. 449, 157 l 3.8.1-3

AC Sources-Operating 3.8.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. Two paths inoperable.

C. 1 Declare required feature(s) 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> from inoperable when its discovery of redundant required Condition C feature(s) is inoperable.

concurrent with inoperability of redundant required features AND C.2 Restore one path to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> OPERABLE status.

D. One path inoperable.


NOTE ----------------

Enter applicable Conditions and AND Required Actions of LCO 3.8.9, "Distribution Systems-One DG inoperable.

Operating," when Condition D is entered with no AC power source to either train.

D. I Restore path to 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> OPERABLE status.

OR D.2 Restore DG to 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> OPERABLE status.

Prairie Island Units I and 2 Unit 1 - Amendment No. -18, 167 Unit 2 - Amendment No. 4l49, 157 l 3.8.1-4

AC Sources-Operating 3.8.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME E. Two DGs inoperable.

E. 1 Restore one DG to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> OPERABLE status.

F. Required Action and F. I Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A, B, AND C, D, or E not met.

F.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> G.

Two DGs inoperable and G.I Enter LCO 3.0.3.

Immediately one or more paths inoperable.

OR One DG inoperable and two paths inoperable.

Prairie Island Units 1 and 2 Unit I-Amendment No..1.5, 167 Unit 2 - Amendment No. 4-49, 157 3.8.1-5