ML042670533

From kanterella
Jump to navigation Jump to search

RAI Security Plan Sections 1 - 9
ML042670533
Person / Time
Site: Watts Bar 
Issue date: 06/28/2004
From: Spaulding D
NRC/NRR/DLPM
To: Scalice J
Tennessee Valley Authority
Spaulding D, NRR/DE/EEIB, 415-2928
References
TAC MC2988
Download: ML042670533 (2)


Text

SAFEGUARDS INFORMATION SAFEGUARDS INFORMATION WARNING: Violation of Section 147 of the Atomic Energy Act, "Safeguards Information" is subject to Civil and Criminal June 28, 2004 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402

SUBJECT:

WATTS BAR NUCLEAR PLANT - REQUEST FOR ADDITIONAL INFORMATION RE: SECURITY PLAN SECTIONS 1 - 9 (TAC NO. MC2988)

Dear Mr. Scalice:

In response to the April 29, 2004, Orders revising the design basis threat, you submitted revised physical security plans, safeguards contingency plans, and guard training and qualification plans, including an implementation schedule, for Watts Bar Nuclear Plant.

The Nuclear Regulatory Commission staff is reviewing your submission and has determined that a request for additional information (RA) is necessary in order to complete its evaluation based on its review of Sections 1 through 9 of your physical security plan. Please respond to the enclosed RAI within 10 days from the date of this letter. If circumstances results in the need to revised the target response date, please contact me at (301) 415-2743.

Sincerely,

/RA/

Deirdre W. Spaulding, Project Manager Security Plan Review Team Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-390

Enclosure:

As stated cc w/o encl: See next page NOTICE: The enclosed information contains Safeguards Information. Upon separation from the Enclosure, this letter is DECONTROLLED

June 28, 2004 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402

SUBJECT:

WATTS BAR NUCLEAR PLANT - REQUEST FOR ADDITIONAL INFORMATION RE: SECURITY PLAN SECTIONS 1 - 9 (TAC NO. MC2988)

Dear Mr. Scalice:

In response to the April 29, 2004, Orders revising the design basis threat, you submitted revised physical security plans, safeguards contingency plans, and guard training and qualification plans, including an implementation schedule, for Watts Bar Nuclear Plant.

The Nuclear Regulatory Commission staff is reviewing your submission and has determined that a request for additional information (RA) is necessary in order to complete its evaluation based on its review of Sections 1 through 9 of your physical security plan. Please respond to the enclosed RAI within 10 days from the date of this letter. If circumstances results in the need to revised the target response date, please contact me at (301) 415-2743.

Sincerely,

/RA/

Deirdre W. Spaulding, Project Manager Security Plan Review Team Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-390

Enclosure:

As stated cc w/o encl: See next page EDO Control (G20040633)

DISTRIBUTION:

PUBLIC SPRT R/F J. Nakoski J. Peralta C. Hawes W. Macon OGC ACRS D. Spaulding E. Brown, K. Jabbour, M. Comar, M. Mashall W. Burton (A)

E. Hackett V. McCree, RII Accession Number: ML042670533 OFFICE SPRT/NRR/PM SPRT/NRR/LA SPRT/NSIR SPRT/NRR/SC NAME Spaulding CHawes JPeralta JNakoski DATE 06/26/04 06/28/04 06/28/04 OFFICIAL RECORD COPY