ML042670335

From kanterella
Jump to navigation Jump to search
E-mail from T. Alexion to D. Millar Comments on Proposed TS Change - Metamic Coupon Sampling
ML042670335
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/15/2004
From: Alexion T
NRC/NRR/DLPM/LPD4
To: Millar D
Entergy Operations
Alexion T W, NRR/DLPM, 415-1326
Shared Package
ML043570180 List:
References
Download: ML042670335 (4)


Text

f . ,

Thomas

,, I . , x~

Alexion

- COMMENTS ON PROPOSED TS .CHArJGE

" . I . I - ~ COUPON SAMPLING PROGRAM

- METAMIC Page 1 to From: Thomas Alexion To: MILLAR, DANA Date: 3/15/04 10:52AM

Subject:

COMMENTS ON PROPOSED TS CHANGE - METAMIC COUPON SAMPLING PROGRAM Dana, See the attached.

Tom

- do- Sb-g13

- CM my

[ CqiW INDOWWEMiG.W)000013.TM C:WiD E- 0 . T Page 1 I Mail Envelope Properties (4055Dl5A.7F9: 0: 20628)

Subject:

COMMENTS ON PROPOSED TS CHANGE - METAMIC COUPON SAMPLING PROGRAM Creation Date: 3115/04 10:52AM From: Thomas Alexion Created By: TWA@nrc.gov Recipients Action Date & Time entergy.com DMILLAR (MILLAR, DANA)

Post Office Delivered Route Pending entergy.com Files Size Date & Time Lauron.wpd 5457 03/15/04 10:50AM MESSAGE 656 03/15/04 10:52AM Options Auto Delete: No Expiration Date: None Notify Recipients: Yes Priority: Standard Reply Requested: No Return Notification: None Concealed

Subject:

No Security: Standard To Be Delivered: Immediate Status Tracking: Delivered & Opened

COMMENTS ON ENTERGY'S PROPOSED TECHNICAL SPECIFICATION METAMIC COUPON SAMPLING PROGRAM ARKANSAS NUCLEAR ONE, UNIT 1 (ANO-1)

Proposed:

TS 5.5.17 Metamic Coupon Sampling Program A coupon surveillance program will be implemented to evaluate performance of the Metamic absorber material that is exposed to the SFP environment. The purpose of the program is to establish the following:

Comment 1: Define that the coupons will be made of the same lot as the full length inserts used in the racks.

a. Withdrawal schedule and examination completion intervals:
1. One coupon will be examined on a two year basis for the first three intervals with the first inspection being performed on or before December 2006. Based on acceptable performance during the initial testing phase, the testing interval will be increased to 5 years over the remaining service life of the inserts.

Comment 2: How is an interval defined? "'..ona two year basis for the first 6 years..."

What is "acceptable performance"? How is this defined (i.e., consistent with assumptions in criticality analyses)? B-10 density Criteria?

2. The examination results will be completed within 18 months of removing the coupon from the SFP.

Comment 3: Basis for 18 months to complete examination results? (assume that 6 months is reasonable).

How does the timinq of the coupon examination results ensure that the criticality analyses remain valid (ie., consider the effect of coupon surveillance results which indicate that the panels do not have the assumed B-10 content)? (The licensee has indicated that the pool will remain subcritical because of a minimum of 800 ppm of boron is needed - pool has 1600 ppm.)

b. Acceptability of the Metamic absorber material by evaluating the following parameters:
1. Physical observations of the coupon surface appearance,
2. Dimensional measurements
3. Weight, and
4. Material composition to confirm the boron (B-1 0) content.

Comment 4: What is the minimum boron (B-10) content assumed in the criticality analyses?

(Value needed)

Comment 5: Reporting requirements for adverse results should also be included.

Page 1 of 2

c. The provisions of SR 3.0.2 and SR 3.0.3 are applicable to the Metamic Coupon Sampling Program NRC notes that SR 3.0.2 allows 1.25 times the specified interval; and SR 3.0.3 allows 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or up to the limit of the specified interval, whichever is greater, for missed surveillances.

Comment 6: What are the consequences of applyingq these provisions to the sampling and testing of the coupons on the criticality analyses submitted to support the amendment should the coupon test results indicate a boron content less than that assumed?

Page 2 of 2