Category:Annual Report
MONTHYEARML19268A0742019-09-0505 September 2019 University of New Mexico, Department of Nuclear Engineering 2019 Annual Report for the AGN-201M Reactor ML15253A2232015-08-26026 August 2015 2015 Annual Report for the AGN-201M Reactor at the University of New Mexico ML13263A1852013-09-13013 September 2013 University of New Mexico - 2013 Annual Report for the AGN-201M Reactor ML0827402672008-09-18018 September 2008 2008 Annual Report for the AGN-201M Reactor Located at the University of New Mexico ML0627900842006-09-29029 September 2006 2006 Annual Report for the AGN-201M Reactor, University of New Mexico ML0424003232004-08-0505 August 2004 2004 Annual Report for the AGN-201M Reactor Located at the University of New Mexico ML0424302682004-08-0505 August 2004 Submittal of 2004 Annual Report for the AGN-201M Reactor 2019-09-05
[Table view] Category:Letter
MONTHYEARML24002B1112023-12-13013 December 2023 University of New Mexico - Response to NOV 05000252/2023201-1 IR 05000252/20232012023-12-12012 December 2023 University of New Mexico - U.S. Nuclear Regulatory Commission Safety Inspection Report No. 05000252/2023201 and Notice of Violation IR 05000252/20232022023-12-11011 December 2023 University of New Mexico U.S. Nuclear Regulatory Commission Security Inspection Report 05000252/2023202 ML23233A0022023-08-24024 August 2023 Examination Confirmation Letter No. 50-252/Ol-24-01, University of New Mexico ML23079A2312023-03-22022 March 2023 Examination Results Letter No. 50-252/OL-23-01, University of New Mexico ML23079A2302023-03-21021 March 2023 Examination Report Letter No. 50-252/OL-23-01, University of New Mexico ML23039A1412023-02-0808 February 2023 Supplement to License Amendment Request to Revise the Licensing and Design Basis to Incorporate the Replacement of Existing Safety-Related Analog Control Systems with a Single Digital Plant Protection System (PPS)-Human Factors Engineering IR 05000252/20222022022-11-0404 November 2022 University of New Mexico U.S. Nuclear Regulatory Commission Safety Inspection Report 05000252/2022202 ML22306A2562022-10-26026 October 2022 Univ. of New Mexico, Nuclear Engineering Department, Letter Regarding Revision to Emergency Plan for the AGN-201M ML22273A0722022-09-27027 September 2022 Univ. of New Mexico, Submittal of the 2022 Annual Report for the AGN-201M ML22242A1052022-09-0808 September 2022 University of New Mexico, Examination Confirmation Letter No. 50-252/OL-23-001, IR 05000252/20222012022-03-11011 March 2022 University of New Mexico - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000252/2022201 ML21294A3252021-10-13013 October 2021 University of New Mexico - 2020-2021 Annual Report for the AGN-201M Reactor ML21270A0802021-09-29029 September 2021 Examination Confirmation Letter No. 50-252/OL-22-01, University of New Mexico RS-21-032, Amended Decommissioning Trust Agreements2021-02-25025 February 2021 Amended Decommissioning Trust Agreements IR 05000252/20202012020-12-23023 December 2020 University of New Mexico - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000252/2020201 - Cover Letter and Enclosure ML20295A4242020-11-16016 November 2020 Notification of Mailing Address Change Regarding Submittal of Fingerprint Cards ML20271A0022020-09-24024 September 2020 2020 Annual Report for the AGN-201M Reactor Located at the University of New Mexico - Docket 50-252 RS-20-110, Request to Use Provisions of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI2020-09-0202 September 2020 Request to Use Provisions of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI ML20192A0772020-06-22022 June 2020 Univ of New Mexico - Advising Staffing Changes Re University of New Mexico'S Agn 201m Nuclear Reactor, Replacing Chief Reactor Supervisor, Dr. Robert Busch with Mr. Carl Willis, a Senior Reactor Operator, Effective 6/30/2020 ML20058J0542020-03-0202 March 2020 Examination Confirmation Letter No. 50-252/OL-20-01, University of New Mexico ML20078J1892020-02-26026 February 2020 Narrative of Event at the University of New Mexico'S AGN-201M Nuclear Reactor ML19308A0402019-11-0707 November 2019 University of New Mexico, Review of the Operator Requalification Program for the Aerojet-General Nucleonics-201 Modified Nuclear Reactor IR 05000252/20182012019-09-18018 September 2019 University of New Mexico - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-252/2018-201 ML19267A0412019-09-10010 September 2019 Submittal of University of New Mexico AGN-201M Facility Response to Request for Additional Information Regarding the Operator Requalification Program for Aetojet General Nucleonics Reactor ML19268A0742019-09-0505 September 2019 University of New Mexico, Department of Nuclear Engineering 2019 Annual Report for the AGN-201M Reactor ML19268A0752019-09-0505 September 2019 University of New Mexico, School of Engineering, Notification of Appointment of Charles Fleddermann as Interim Chair of Department of Nuclear Engineering ML19190A3212019-07-16016 July 2019 University of New Mexico, Request for Additional Information Regarding the Operator Requalification Program for the Aerojet-General Nucleonics-201 Modified Nuclear Reactor ML19052A0502019-01-30030 January 2019 Univ. of New Mexico - Submittal of Revised Operator Requalification Plan ML19016A4612019-01-17017 January 2019 Examination Confirmation Letter No. 50-252/OL 19-01, University of New Mexico ML18254A1772018-08-28028 August 2018 2018 Annual Report for the AGN-201M Reactor Located at the University of New Mexico - Docket 50-252 ML18134A1192018-07-17017 July 2018 University of New Mexico, Issuance of Amendment No. 6 to Renewed Facility Operating License No. R-102 for the Aerojet-General Nucleonics-201 Modified Reactor ML18183A4662018-06-13013 June 2018 Univ of New Mexico - Staffing Change Update ML18179A1682018-06-13013 June 2018 University of New Mexico - Staffing Change ML18101A0302018-03-28028 March 2018 the Univ. of New Mexico - Acknowledgement of Four Corrections or Clarifications That Were Required During Review of Technical Specifications and Changes in Letter Dated September 28, 2015 for AGN-201M Reactor Located at the Univ ML17297A8442017-12-0606 December 2017 Univ. Nm 2017 -Public Letter Security Inspection ML17304B4702017-11-14014 November 2017 University of New Mexico, Change of Facility Project Manager IR 05000252/20172012017-11-0808 November 2017 University of New Mexico - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-252/2017-201 ML17263A0472017-09-19019 September 2017 Email Review of the Technical Specifications for the AGN-201M at Unm, Changes Are Needed (Redacted) ML17165A2972017-05-22022 May 2017 Submittal of University of New Mexico AGN-201M Facility Response to Request for Additional Information Regarding Amendment to Facility Operating License No. R-102 for the University of New Mexico Aerojet General Nucleonics AGN-201M Reactor ML16041A5962017-04-25025 April 2017 University of New Mexico - Request for Additional Information for License Amendment No. 5 to the Facility Operating License No. R-102 Aerojet General Nucleonic AGN-201M Research Reactor ML17053A1032017-01-17017 January 2017 University of New Mexico Letter Providing Information on Two Staffing Changes Effective December 31, 2016 ML16306A4102016-10-26026 October 2016 Submittal of University of New Mexico AGN-201M Facility Response to GL 2016-01, Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools ML16291A0172016-10-20020 October 2016 Examination Report No. 50-252/OL-16-02, University of New Mexico AGM-201M Reactor IR 05000252/20162012016-10-0505 October 2016 University of New Mexico - NRC Routine Inspection Report 05000252/2016201 ML16306A4072016-08-31031 August 2016 University of New Mexico AGN-201M Reactor - 2016 Annual Report ML16204A0402016-07-22022 July 2016 Examination Notification Letter, No. 50-252/OL-16-002, University of New Mexico L-16-002, Examination Notification Letter, No. 50-252/OL-16-002, University of New Mexico2016-07-22022 July 2016 Examination Notification Letter, No. 50-252/OL-16-002, University of New Mexico ML16073A0062016-03-24024 March 2016 Examination Report No 50-252/OL-16-01, University of New Mexico ML15337A1462015-12-0303 December 2015 Examination Notifcation Letter No. 50-252/OL-16-01, University of New Mexico 2023-08-24
[Table view] |
Text
The University of New Mexico Chemical & Nuclear Engineering MSCOI 1120 I University of New Mexico Albuquerque, NM 87131-0001 August 5, 2004 Pat Isaac Project Manager Non-Power Reactors and Decommissioning Project Directorate Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington D.C. 20555-0001 Dear Mr. Isaac; Enclosed is the 2004 Annual Report for the AGN-201M reactor located at the University of New Mexico - Docket 50-252.
Sincerely, Robert D. Busch, Ph.D, P.E. Anil K. Prinja, Ph.D.
Chief Reactor Supervisor Reactor Administrator cc: Document Control Desk, USNRC A-O(
209 Farris Engineering Bldg. 2 505-277-5431
f REPORT ON FACILITY LICENSE NO. R-102 THE UNIVERSITY OF NEW MEXICO JULY 1, 2003 - JUNE 30,2004 The University of New Mexico's AGN-201M reactor was used for some research during 2003-2004. This was a continuation of the research from the previous year and involved subcritical multiplication and die-away measurements at power levels below I microWatt. There were no changes in facility design, performance characteristics, or operating procedures related to reactor safety during the reporting period. The NRC did an on-site review of the facility in October 2003 and found no safety concerns or noncompliance issues.
The AGN-201 M Reactor Facility is an essential part of our educational program, including public education, and continues to serve us well. The use of the reactor from July of 2003 through June of 2004 was as follows:
Type of Use July 03 - June 04 July 03 - June 04 Hours Watt-hours Class Demonstrations 0.8 0.8 Faculty Research 3.0 0.0 Graduate Student Research 0.0 0.0 Maintenance and Equipment Check 12.5 0.0 Operator Training and Requalification 12.1 29.1 Teaching l 40.0 98.7 Totals for the Year 68.4 128.65 During the annual maintenance in August 2003, we checked the detector cans and found corrosion on the Channel 1 can. This can was replaced wmith a PVC container as an interim. All detector cans will be inspected again as part of the 2004 annual maintenance.
AGN-201 01-03 Report, Page 3 There were no changes to the facility as it is described in the application for license and amendments thereto, nor were there any changes to the procedures as described in Facility Technical Specifications. No new experiments were performed during the reporting period.
There were no 10 CFR 50.59 issues during the reporting period. During the reporting period, there was no liquid radioactive waste released from the facility nor was there any solid waste released. There were no environmental radiation surveys performed outside the facility. All personnel exposures received during the reporting period were below 50 mrem per person with the majority of personnel receiving below 5 mrem. No facility visitors received measurable exposures.
Dr. Anil Prinja has replaced Dr. Norman Roderick as director of the nuclear engineering program and reactor administrator. The current personnel assignments are:
Dean, College of Engineering Joseph Cecchi Chair, Department of Chemical and Nuclear Engineering Julia Fulghum Reactor Administrator Anil K. Prinja Chief Reactor Supervisor Robert D. Busch USNRC-licensed Senior Reactor Operators Robert D. Busch Ken Carpenter Gary Cooper The current makeup of the Reactor Safety Advisory Committee is:
James Bryson Ron Knief Robert Long Ted Schmidt Joseph Sholtis David Summers with no vacant position although Ted Schmidt has retired from Sandia and may soon be retiring from the committee.
AGN-201 01-03 Report, Page 3 The University of New Mexico's AGN-201M reactor continues to be used extensively for teaching experiments as a part of our undergraduate and graduate programs. These experiments include approach-to-critical, reactor period and reactivity measurements, importance functions measurements, sample activation, control rod calibrations, and reactor power and neutron fluence measurements. The reactor is also used throughout the Fall, Spring and Summer sessions of the University. All experiments have received prior approval from ok Reactor Safety Advisory Committee. l , A,4 7 Anil K. Prinja lI Reactor Administrator