ML041970193

From kanterella
Jump to navigation Jump to search

RAI, Security Plan Sections 1 - 9
ML041970193
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 06/28/2004
From: Spaulding D
NRC/NRR/DLPM
To: O'Connor W
Detroit Edison
Spalding D, NRR/DLPM/LPD3-1, 415-2928
References
TAC MC2920
Download: ML041970193 (3)


Text

SAFEGUARDS INFORMATION June 28, 2004 Mr. William T. OConnor, Jr.

Vice President - Nuclear Generation Detroit Edison Company 6400 North Dixie Highway Newport, MI 48166

SUBJECT:

FERMI, UNIT 2, AND - REQUEST FOR ADDITIONAL INFORMATION RE:

SECURITY PLAN SECTIONS 1 - 9 (TAC NO. MC2920)

Dear Mr. O'Connor:

In response to the April 29, 2003, Orders revising the design basis threat, you submitted revised physical security plans, safeguards contingency plans, and guard training and qualification plans, including an implementation schedule, for Fermi, Unit 2.

The Nuclear Regulatory Commission staff is reviewing your submission and has determined that a request for additional information (RAI) is necessary in order to complete its evaluation based on its review of Sections 1 through 9 of your physical security plan. Please respond to the enclosed RAI within 10 days from the date of this letter. If circumstances result in the need to revise the target response date, please contact me at (301) 415-2743.

Sincerely, Deirdre W. Spaulding, Project Manager Security Plan Review Team Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-341

Enclosure:

As stated cc w/o encl: See next page WARNING: Violation of Section 147 of NOTICE: The enclosed information contains Safeguards the Atomic Energy Act, Safeguards Information is subject to Civil and Information. Upon separation from the Enclosure, this Criminal Penalties letter is DECONTROLLED.

SAFEGUARDS INFORMATION

June 28, 2004 Mr. William T. OConnor, Jr.

Vice President - Nuclear Generation Detroit Edison Company 6400 North Dixie Highway Newport, MI 48166

SUBJECT:

FERMI, UNIT 2, AND - REQUEST FOR ADDITIONAL INFORMATION RE:

SECURITY PLAN SECTIONS 1 - 9 (TAC NO. MC2920)

Dear Mr. O'Connor:

In response to the April 29, 2003, Orders revising the design basis threat, you submitted revised physical security plans, safeguards contingency plans, and guard training and qualification plans, including an implementation schedule, for Fermi, Unit 2.

The Nuclear Regulatory Commission staff is reviewing your submission and has determined that a request for additional information (RAI) is necessary in order to complete its evaluation based on its review of Sections 1 through 9 of your physical security plan. Please respond to the enclosed RAI within 10 days from the date of this letter. If circumstances result in the need to revise the target response date, please contact me at (301) 415-2743.

Sincerely,

/RA/

Deirdre W. Spaulding, Project Manager Security Plan Review Team Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-341

Enclosure:

As stated cc w/o encl: See next page DISTRIBUTION:

PUBLIC SPRT R/F J. Nakoski J. Peralta C. Hawes W. Macon OGC ACRS PM D. Beaulieu L. Raghavan B. Ruland S. Reynolds, RIII ADAMS Accession Number: ML041970193 OFFICE SPRT/NRR/PM SPRT/NRR/LA SPRT/NSIR SPRT/NRR/SC NAME DWSpaulding CHawes JPeralta JNakoski DATE 6/26/04 6/28/04 6/28/04 OFFICIAL RECORD COPY

Fermi 2 cc:

Mr. Peter Marquardt Legal Department 688 WCB Detroit Edison Company 2000 2nd Avenue Detroit, MI 48226-1279 Michigan Department of Environmental Quality Waste and Hazardous Materials Division Hazardous Waste and Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P.O. Box 30241 Lansing, MI 48909-7741 U.S. Nuclear Regulatory Commission Resident Inspectors Office 6450 W. Dixie Highway Newport, MI 48166 Monroe County Emergency Management Division 963 South Raisinville Monroe, MI 48161 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Norman K. Peterson Director, Nuclear Licensing Detroit Edison Company Fermi 2 - 280 TAC 6400 North Dixie Highway Newport, MI 48166 Mr. William T. OConnor, Jr.

Vice President - Nuclear Generation Detroit Edison Company 6400 North Dixie Highway Newport, MI 48166