NLS2004048, 2003 Annual Radiological Environmental Operating Report

From kanterella
(Redirected from ML041340134)
Jump to navigation Jump to search

2003 Annual Radiological Environmental Operating Report
ML041340134
Person / Time
Site: Cooper 
Issue date: 05/05/2004
From: Fleming P
Nebraska Public Power District (NPPD)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NLS2004048
Download: ML041340134 (200)


Text

Nebraska Public Power District Always there when you need us NLS2004048 May 5, 2004 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001

Subject:

Annual Radiological Environmental Operating Report Cooper Nuclear Station, NRC Docket No. 50-298, DPR46 The purpose of this letter is to submit the Cooper Nuclear Station (CNS) Annual Radiological Environmental Operating Report for the period of January 1, 2003, through December 31, 2003. The enclosed report is being submitted in accordance with CNS Technical Specification 5.6.2.

Per 10 CFR 50.4(b)(1), we are enclosing one copy of the report for your use, one copy to the Regional Office and one copy to the NRC Senior Resident Inspector.

Should you have any questions regarding this submittal, please contact Paul V.

Fleming, Licensing Manager, at 402-825-2774.

/cb Enclosure cc:

Regional Administrator w/enclosure USNRC - Region IV Senior Project Manager w/enclosure USNRC - NRR Project Directorate IV-1 Senior Resident Inspector w/enclosure USNRC - Cooper Nuclear Station NPG Distribution w/o enclosure Records COOPER NUCLEAR STATION P.O. Box 98 / Brownville, NE 68321-0098 Telephone: (402) 825-3811 / F3.v: (402) 825-5211 www.nppd.com 2)

ATTACHMENT 3 LIST OF REGULATORY COMMITMENTSl Correspondence Number: NLS2004048 The following table identifies those actions committed to by Nebraska Public Power District (NPPD) in this document. Any other actions discussed in the submittal represent intended or planned actions by NPPD. They are described for information only and are not regulatory commitments. Please notify the Licensing & Regulatory Affairs Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.

COMMITTED DATE COMMITMENT OR OUTAGE None 4

4 4

4 4

+

+

PROCEDURE 0.42 l

REVISION 15 l

PAGE 18 OF 24l

Cooper Nuclear Station Annual Radiological Environmental Operating Report Radiological Environmental Monitoring Program January 1, 2003 - December 31, 2003 USNRC Docket Number 50-298 Nebraska Public Power District Always there when you need us Prepared by TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES g115583.zip

NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION Radiological Environmental Monitoring Program 2003 Annual Report January 1, 2003 to December 31, 2003 Approved by Keith Jeter Laboratory Director ozt

7 Prepared by Teledyne Brown Engineering 2508 Qualify Lane Knoxville, TN 37931-3133

TABLE OF CONTENTS SECTION TITLE PAGE Preface...........................................

6 I.

Introduction...................................

7 II.

Summary...........................................

10 III.

Sampling and Analyses Program 12 IV.

Summary and Discussion of 2003 Analytical Results 17 A. Airborne Particulates

............................... 18 B. Airborne Iodine 20 C. Fish............................................

20 D. Milk - Nearest Producer 20 E. Milk - Other Producers 20 F. Ground Water 23 G. River Water..........................................

23 H. Thermoluminscent Dosimeters 23 I. Food - Broadleaf Vegetation 23 J. Shoreline Sediment 23 V.

Conclusions..........................................

30 VI.

Radiological Environmental Monitoring Program Summary Table - 2003..........................................

32 VII.

Complete Data Tables 37 VIII.

References 93 2

TABLE OF CONTENTS (Cont)

APPENDICES APPENDIX A - 2003 Land Use Census.................................................

A-I APPENDIX B - Summary of Interlaboratory Comparisons............................... B-1 APPENDIX C - Synopsis of Analytical procedures........................................... C-1 APPENDIX D-Detection Limits and Reporting Levels.................................... D-1 APPENDIX E - REMP Sampling and Analytical Exceptions............................ E-l APPENDIX F - Summary of Doses to a Member of the Public Offsite............. F-I APPENDIX G - REMP Sample Station Descriptions....................................... G-1 LIST OF FIGURES

1.

Map of Sampling Stations.................................................

15 3

TABLE OF CONTENTS (Cont)

LIST OF TRENDING GRAPHS

1.

Gross Beta in Air Particulates.............................................

19

2.

Cesium-137 in Fish..............................................

21

3.

Iodine-131 and Cesium-137 in Milk -Nearest Producer.......................... 22

4.

Iodine-131 and Cesium-137 in Milk - Other Producers............................ 24

5.

Tritium in Ground Water..............................................

25

6.

Tritium in River Water..............................................

26

7.

Thermoluminescent Dosimetry.............................................

28

8.

Iodine-131, Cesium-134, and Cesium-137 in Shoreline Sediment............ 29 4

TABLE OF CONTENTS (Cont)

LIST OF TABLES 1

Sampling Schedule and Analyses...............................................

14 VII-I Exposure Pathway - Airborne Air Particulate & Charcoal Filters...... 38 VII-2 Exposure Pathway - Airborne Composite Air Particulate Filters....... 58 VII-3 Exposure Pathway - Ingestion Fish.....................................................68 VII-4 Exposure Pathway - Ingestion Milk Nearest Producer....................... 70 VII-5 Exposure Pathway - Ingestion Milk Other Producers......................... 76 VII-6 Exposure Pathway - Ingestion Water - Ground.................................. 79 VII-7 Exposure Pathway - Ingestion Water - River..................................... 81 VII-8 Exposure Pathway - Thermoluminescent Dosimetry - TLD.............. 87 VII-9 Exposure Pathway - Ingestion Vegetation - Terrestrial, Broadleaf.... 89 VII-I0 Exposure Pathway - Airborne Shoreline Sediment............................. 92 5

PREFACE This report covers the period of January I through December 31, 2003. Personnel of the Nebraska Public Power District made all sample collections. Analyses were performed and reports of analyses were prepared by Teledyne Brown Engineering -

Environmental Services and forwarded to Nebraska Public Power District. Environmental Thermoluminescent Dosimeter (TLD) analyses were performed and reports of analyses were prepared by Proxtronics, Inc.

6

SECTION I. INTRODUCTION 7

I. INTRODUCTION This report contains a complete tabulation of data collected during the period January through December 2003, for the operational Radiological Environmental Monitoring Program performed for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) by Teledyne Brown Engineering - Environmental Services.

Cooper Nuclear Station is located in Nemaha County in the southeast corner of Nebraska on the Missouri River. A portion of the site extends into Missouri. The reactor is a 778-megawatt (net electrical) boiling water reactor. Initial criticality was attained on February 21, 1974. The reactor reached 50 percent power on June 25, 1974 and 100 percent power on November 20, 1974.

Radiological environmental monitoring began in 1971 before the plant became operational and has continued to the present. The program monitors radiation levels in air, terrestrial and aquatic environments. All samples are collected by NPPD personnel.

All samples are shipped for analysis to a contractor's laboratory where there exists special facilities required for measurements of extremely low levels of radioactivity. From 1971 through 1976 the contractor was Teledyne Isotopes, Westwood, New Jersey. NALCO Environmental Sciences assumed responsibility for the analyses effective January 1, 1977.

On November 1, 1978 Hazelton Environmental Sciences Corporation (HESC) assumed responsibility for the program.

Prior to November 1, 1978 Hazelton Environmental Sciences operated as NALCO Environmental Sciences.

Teledyne Isotopes (now trading as Teledyne Brown Engineering - Environmental Services) again assumed responsibility for the analyses effective January 1, 1979 through December 31, 2003.

The United States Nuclear Regulatory Commission (USNRC) regulations (10CFR50.34a) require that nuclear power plants be designed, constructed, and operated to keep levels of radioactive material in effluents to unrestricted areas as low as is reasonably achievable (ALARA). To ensure these criteria are met, the operating license for Nebraska Public Power District's Cooper Nuclear Station includes the Technical Requirement Manual which addresses the release of radioactive effluents.

Inplant monitoring is used to ensure that these release limits are not exceeded. As a precaution against unexpected or undefined environmental processes which might allow undue accumulation of radioactivity in the environment, a program for monitoring the plant environs is also included in NPPD's CNS Offsite Dose Assessment Manual (ODAM).

8

A.

Atmospheric Nuclear Tests Three atmospheric nuclear detonations in the People's Republic of China influenced program results significantly in late 1976 and in 1977.

Two of these detonations occurred in late 1976 (September 26 and November 17) and one in late 1977 (September 17). As a consequence of these tests elevated activities of gross beta in air particulate filters and I-131 in milk were observed throughout most of the United States. No atmospheric nuclear tests have been conducted since 1980, thus no short-lived fission products were detected in air particulate samples.

On April 26, 1986 the fire and explosion of Chernobyl Reactor No. 4 in the Soviet Union resulted in the release of fission products to the atmosphere and worldwide fallout.

Following the explosion, elevated levels of gross beta activities in air particulates and Iodine-131 in charcoal filters and milk samples were measured. Additionally, in 1986, Cesium-137 and the short-lived radionuclides Iodine-131, Ruthenium-106, and Cesium-134 were detected in broadleaf vegetation. Similar results occurred in other areas of the United States and the entire Northern Hemisphere.

B.

Program Obiectives and Data Interpretation The objective of the monitoring program is to detect and assess the impact of possible releases to the environs of radionuclides from the operations of the Cooper Nuclear Station. This objective requires measurements of low levels of radioactivity equal to or lower than pre-determined limits of detection. In addition the source of the environmental radiation must be established. Sources of environmental radiation include:

(1)

Natural background radiation from cosmic rays (Beryllium-7).

(2)

Terrestrial, primordial radionuclides from the environment (potassium-40, Radium-226, Thorium-228).

(3)

Fallout from atmospheric nuclear tests such as the September 1977 detonation by the Peoples' Republic of China and the atmospheric weapons test of October 16, 1980 (fission products and fusion products).

(4)

Releases from nuclear power plants such as CNS (fission products and neutron activation products).

(5)

Fallout from the Chernobyl Nuclear Reactor Accident.

Radiation levels measured in the vicinity of an operating power station are compared with preoperational measurements at the same locations to distinguish power plant effects from other sources. Also, results of the monitoring program are related to events known to cause elevated levels of radiation in the environment, e.g., atmospheric nuclear detonations or abnormal plant releases.

9

SECTION II.

SUMMARY

10

II.

SUMMARY

Presented in this report are summaries and discussions of the data generated for the Radiological Environmental Monitoring Program (REMP) for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) for 2003.

The sampling and analyses program is described in Section III. It contains the sampling schedule and required analyses in Table I and the site map.

A discussion of each type of sample analyzed and its impact, if any, on the environment is presented in Section IV. Included are graphs of the radionuclides of interest for the past several years and the statistical results for each quarter of the year.

Section V presents the yearly conclusions of the program.

Section VI is the Radiological Environmental Monitoring Program Summary. It contains the yearly summary of the program with the total number of samples of each type analyzed.

It lists the yearly average and range for the control locations versus the indicator locations and the number of detections per total number of samples. It identifies the station with the highest yearly average, the distance and location of that station and provides the range of detection.

Section VII contains the complete data tables for the period.

References are presented in Section VIII.

11

SECTION III. SAMPLING AND ANALYSES PROGRAM 12

III.

SAMPLING AND ANALYSES PROGRAM The 2003 sampling and analyses program is described in Table 1. Teledyne Brown Engineering Environmental Services has a

comprehensive quality assurance/quality control program designed to assure the reliability of data obtained. The results for the 2003 Interlaboratory Comparison Program conducted by the Analytic's, Inc. and Environmental Resource Associates are contained in Appendix B.

Sampling locations are indicated in the map labeled Figure 1. The sample types collected at each location and the approximate distance and direction from the reactor elevated release point are specified.

The annual land use census for 2003 is described in Appendix A. There were no milk animals found within three miles of CNS in 2003 and no evidence of potable water use from the river. The nearest garden to CNS is in sector N, 1 mile from CNS. Gardens were found in nine sectors during 2000, in eight sectors during 2001, in seven sectors during 2002, and in eight sectors during 2003. The nearest resident to CNS is in sector Q, 0.9 miles from CNS.

All of the required 2003 environmental monitoring, including sampling and analyses, was conducted as specified in Table D4.l -1 of the CNS Offsite Dose Assessment Manual (ODAM), except as noted in Appendix E, REMP Sampling and Analytical Exceptions table.

13

TABLE I NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION Environmental Radiation Surveillance Program Sampling Schedule andAnalyses Sample Type Airborne/

Particulate Airborne/lodine Milk / Nearest Producer peak pasture only River Water Milk/ Nearest Producer Non-peak pasture Food Products / Broadleaf Vegetation Background Radiation Thermoluminescent Dosimeters Groundwater Milk Other Producers Station 1-10 Frequency Once per 7 days 1-10 61,99 Once per 7 days Once per 15 days 28,35 Once per 31 days Analyses Gross beta. Gamma Isotopic on quarterly composite of each station, and on each sample in which gross beta activity is >10 times the yearly mean of control samples 1-131 1-131 (low level), Gamma Isotopic analysis of each sample Gamma Isotopic, each sample Tritium on quarterly composite 1-131 (low level), Gamma Isotopic analysis of each sample 1-131 (low level), Gamma Isotopic analysis of each sample TLD Readout (gamma dose) 1-131 (low level), Gamma Isotopic, Tritium 1-131 (low level), Gamma Isotopic 61,99 Once per 31 days 28,35,96,101 1-10,20,44,56,58,59, 66,67,71,79-91, 94 11,47 99, 100,102 Monthly when required Once per 92 days Once per 92 days Once per 92 days Fish (Summer and Fall)

Shoreline Sediment 28,35 28 Two times per year Two times per year Gamma Isotopic on edible portions Gamma Isotopic 14

SECTION IV.

SUMMARY

AND DISCUSSION OF 2003 ANALYTICAL RESULTS 17

IV.

SUMMARY

AND DISCUSSION OF 2003 ANALYTICAL RESULTS Data from the radiological analyses of environmental media collected during 2003 are tabulated and discussed below. The procedures and specifications followed in the laboratory for these analyses are as required in the Teledyne Brown Engineering Quality Assurance manual and are explained in the Teledyne Brown Engineering Analytical Procedures. A synopsis of analytical procedures used for the environmental samples is provided in Appendix C. In addition to internal quality control measures performed by Teledyne, the laboratory also participates in an Interlaboratory Comparison Program.

Participation in this program ensures that independent checks on the precision and accuracy of the measurements of radioactive material in environmental samples are performed. The results of the Interlaboratory Comparison are provided in Appendix B.

Radiological analyses of environmental media characteristically approach and frequently fall below the detection limits of state-of-the-art measurement methods. The "less than" values in the data tables were calculated from each specific analysis and are dependent on sample size, detector efficiency, length of counting time, chemical yield (when appropriate) and the radioactive decay factor from time of counting to time of collection. Teledyne Brown Engineering's analytical methods meet or are below the Lower Limit of Detection (LLD) requirements given in Table 2 of the USNRC Branch Technical Position, Radiological Monitoring Acceptable Program (November 1979, Revision 1). Section C contains a discussion of the LLD formulas.

The following is a discussion and summary of the results of the environmental measurements taken during the 2003 reporting period:

A.

Airborne Particulates Gross beta activity was observed in 519 of the 519 indicator samples collected during 2003. The average concentration was 0.023 pCi/m3 and a range of 0.005 to 0.070 pCi/m3. The results of the gross beta activities are presented in Section VII-I and Trending Graph 1. The gross beta activities for 2003 were comparable to levels measured in the previous several years. Prior to that period the gross beta activities were higher due to atmospheric nuclear weapons testing performed in other countries. The preoperational period of 1971 through 1974 averaged 0.098 pCi/M3 gross beta.

Air particulate filters were collected weekly and composited by locations on a quarterly basis. They were analyzed by gamma ray spectroscopy. The results are presented in Section VII-2. Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation, was measured in 40 of 40 composite samples. The indicator locations had an average concentration of 0.111 pCi/M3 and a range of 0.060 to 0.187 pCi/m3. During the preoperational period, beryllium-7 was measured at comparable levels. All other gamma emitters were below the detection limits.

18

TRENDING GRAPH 1 GROSS BETA IN AIR PARTICULATES MONTHLY AVERAGE - ALL LOCATIONS I -

0.1 jONSE

%mm%

AD E

0.

0.01 0.001 0.0001 9

0 p

95 qA qA 90 q0 qO qq 9

s Beta

° Im Gross Betal

B.

Airborne Iodine Charcoal cartridges used to collect airborne iodine were collected weekly and analyzed by gamma spectrometry for iodine-131.

Stations 01 through 10 were monitored. The results are presented in Section VII-1. All results were below the required lower limit of detection.

C.

Fish Aquatic biota can be sensitive indicators of radionuclide accumulation in the environment because of their ability to concentrate certain chemical elements, which have radio isotopes. The results are presented in Table VII-3 and Trending Graph 2. Nine samples of fish were collected during the summer and fall of 2003.

A middle-top feeding fish (carp) and a bottom feeding fish (catfish) were collected in July and September, and an extra QA sample of carp was taken in September. These samples were analyzed by gamma ray spectroscopy. Naturally occurring potassium40 was detected in all samples. The average concentration at the upstream control location was 3088 pCi/kg (wet weight) and a range of 2650 to 3340 pCi/kg (wet weight). The average concentration for the five indicator samples was 2874 pCi/kg (wet weight) with a range of 2620 to 3140 pCi/kg (wet weight). The preoperational period of 1971 through 1974 averaged 2400 pCi/kg potassium-40. All other gamma emitters were below their detection levels.

D.

Milk - Nearest Producer Milk samples are collected once every 15 days in peak pasture season and once every 31 days the rest of the year. The results are presented in Table VII-4 and Trending Graph 3. In May 2003, station 99 replaced station 61 as the nearest milk producer.

Eighteen samples were analyzed by gamma ray spectroscopy.

Naturally occurring potassium-40 was measured in all samples with an average of 1297 pCi/liter and a range of 1150 to 1440 pCi/liter. The highest station was Station 99 with an average of 1318 pCi/liter and a range from 1150 to 1440 pCi/liter. All other gamma emitters were below their detection levels.

E.

Milk - Other Producers Eight milk samples were collected from three locations of other producers during 2003 and results are presented in Table VII-5 and Trending Graph 4. Station 99, station 100 and station 102 were sampled quarterly in 2003. In July 2003, station 102 replaced station 99 as an "other producer". Naturally occurring potassium-40 was detected in all eight samples analyzed with an average concentration of 1430 pCi/liter and a range of 1250 to 1640 pCi/liter. The highest station was Station 99 with an average of 1485 pCi/liter and a range from 1390 to 1580 pCi/liter. All other gamma emitters were below their detection levels. The operation of the Cooper Nuclear Station has no discernable impact on milk samples.

20

TRENDING GRAPH 2 CESIUM-137 IN FISH ALL LOCATIONS 1000.0 -

100.0 l a)

c.

.0 1.0

  • 0.1
  • 11 I!

t-a 9

,9 A

9 AJ 0

cp

,99 9,0°

,0 0

,0 Cit 5s; G - Cs-137 --

Cs-137 ODAM LLD I

TRENDING GRAPH 3 IODINE-131 AND CESIUM-137 IN MILK - NEAREST PRODUCER STATIONS 61 & 99 100.0 10.0 I

0 0.

ip to W,

1.0 I1 p

p p

p 0.1 I

I Co Co CP 311 '' 01 '(Z '& & 59

'& 0 lz 311



 40 49 f 40 C09 011 01 40 '_Pll 1e""

- -Station 61 1-131(RC)

-- Station 61 Cs-137 A&Station 99 1-131 (RC)

--- Station 99 Cs-i1 37 1-131 ODAM LLD

-4*- Cs-137 ODAM LLD Station 61 went out of business in May, 2003. Station 99 replaced station 61 in May, 2003.

F.

Ground Water Groundwater was collected from two stations quarterly and analyzed for tritium and for gamma emitting radionuclides. Station 11 is located 0.15 miles from the plant and station 47 is 25.8 miles from the plant. The results are presented in Table VII-6 and Trending Graph 5. There were no radionuclides measured above their detection levels.

G.

River Water River water was collected monthly and monitored for gamma emitting radionuclides. A quarterly composite was measured for tritium. The results are presented in Table VII-7 and Trending Graph 6. Potassium40 was measured in one of twelve control samples with a concentration of 429 pCi/liter. Potassium-40 was measured in one of twelve indicator samples with a concentration of 308 pCi/liter. Thorium-228 was measured in one of twelve indicator samples with a concentration of 200 pCi/liter. No other gamma emitters were detected. Tritium was not detected.

H.

Thermoluminescent Dosimeters Thermoluminescent dosimeters (TLDs) determine environmental radiation doses and the results are presented in Table VII-8 and Trending Graph 7. Ambient radiation was monitored at 32 locations within a 10 mile radius of the Cooper Nuclear Station and collected quarterly. The quarterly average for the indicator locations was 9.2 millirem/quarter and a range from 2.4 to 34.0 millirem/quarter.

The control station 44, which is located 10.5 miles, 270 degrees had an average of 10.8 millirem/quarter and a range from 5.4 to 14.1 millirem/quarter. The highest station was Station 7 with an average of 15.2 millirem/quarter and a range from 6.8 to 34.0 millirem/quarter. The preoperational period of 1971 through 1974 averaged 7.0 millirem/quarter. The data from year to year is in good agreement and indicates no adverse changes in radiation exposure to the population near the Cooper Nuclear Station.

1.

Food - Broadleaf Vegetation As stated in the CNS ODAM vegetation samples are not required as long as milk samples are available, therefore, no vegetation analyses are included in this report.

J.

Shoreline Sediment Sediment samples were collected during May and October from Station 28 and were analyzed by gamma spectrometry. The results are presented in Table VII-10 and Trending Graph 8.

One man-made and a number of naturally occurring radionuclides were detected in these samples. Cesium-137 was detected in two of two samples with an average activity of 56.9 pCi/kg (dry weight) and a range from 39.0 to 74.8 pCi/kg (dry weight), which is less than the ODAM LLD.

Naturally occurring potassium-40 was observed in the two samples with an 23

TRENDING GRAPH 4 IODINE-131 AND CESIUM-137 IN MILK - OTHER PRODUCERS QUARTERLY AVERAGE - ALL LOCATIONS 100.0 10.0 ci 0C.

1.0 0.1 4-CO

,0D1 I-4-l-131(RC) --

CS-137 A-1-131 ODAM LLD --

Cs-137 ODAM LLDl Due to delay in analysis, sample results for 1-131 for the first quarter of 2001 were excluded and are not plotted.

TRENDING GRAPH 5 TRITIUM IN GROUND WATER QUARTERLY AVERAGE - ALL LOCATIONS 10000.0 1000.0 0a.

A A

Ln 100.0 10.0 cP IN, so

-U-H-3

- H-3 ODAM LLD

TRENDING GRAPH 6 TRITIUM IN RIVER WATER QUARTERLY AVERAGE - ALL LOCATIONS an 10000.0 -

1000.0 -

e 100.0-10.0 1.0 ->

§ I r-T rl-694 a95 K99

\\99 9969 9O 9° 9

99b Bi i

i

§ oglbop@~

I I-0-H-3 -U-H-3 ODAM LLD I

average activity of 17450 pCi/kg (dry weight) and a range from 16500 to 18400 pCi/kg (dry weight). Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation, was measured in two of two samples with an average activity of 228 pCi/kg (dry weight) and a range from 169 to 287 pCi/kg (dry weight).

Radium-226 was measured in one of the two samples with a concentration of 2260 pCi/kg (dry weight). Thorium-228 was observed in the two samples with an average concentration of 3065 pCi/kg (dry weight) and a range from 2520 to 3610 pCi/kg (dry weight).

All other gamma emitters were below their detection limits.

27

TRENDING GRAPH 7 THERMOLUMINESCENT DOSIMETRY QUARTERLY AVERAGE - ALL LOCATIONS 1000 to3 co co co N

a)

E 100 10 1

.i 1995 1995 1996 1996 1997 1997 1998 1998 1999 1999 2000 2000 2001 2001 2002 2002 2003 2003 2004

-+ Exposure Pathway - Ambient Gamma Radiation: TLD I

TRENDING GRAPH 8 IODINE-131, CESIUM-134, AND CESIUM-137 IN SHORELINE SEDIMENT STATION 28 1000.000 i

i I

-5 100.000 D

10.000 1.000 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 1-131 -U--Cs-134 A Cs-137 -4Cs-134 ODAM LLD --

Cs-137 ODAM LLDI 2003 2004 Due to delay in analysis, sample results for 1-131 for the second quarter of 2000 were excluded and are not plotted.

The ODAM does not list an LLD for 1-131.

SECTION V. CONCLUSIONS 30

V.

CONCLUSIONS The results of the 2003 Radiological Environmental Monitoring Program (REMP) for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) have been presented. The report contains data tables, summaries, and discussions of the data and trending graphs.

Naturally occurring radioactivity and residual traces of fallout were observed in sample media in the expected ranges. They have been discussed individually in the text.

Observed radioactivity was at very low concentrations.

The results of the analyses have been presented. Based on the evidence of the Radiological Environmental Monitoring Program, the Nebraska Public Power District, Cooper Nuclear Station has had no discernable radiological impact on the environment and is operating within regulatory limits.

31

SECTION VI. RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

TABLE - 2003 32

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Location of Facility Cooper Nuclear Station Nernaha, Nebraska (County, State)

Docket No.

50-298 Reporting Period January 1, 2003 to December 31. 2003 Type &

Lower Limit All Indicator Control Medium of Pathway Total No.

of Locations Location with Highest Annual Mean Location No. of Sampled of Analyses Detection (I)

Mean (2)

Name Mean ( ) (2)

Mean ( ) (2)

Reportable (Unit of Measurement)

Performed (LLD)

Range (2)

Range (2)

Range (2)

Occurrences Air Iodine (pCi/mn) 1-131 519 0.07 ND (0/519)

(ND-ND)

NA NA NA (0/0)

(NA-NA)

(NA-NA) 0 Air Particulate (pCi/M3)

Gross Beta (Weekly)

Be-7 519 0.01 0.023(519/519)

(0.005-0.070) 40 NA 0.111(40/40)

(0.060-0.187)

Sta. 2 0.75 mi.

Sta. 9 7.3 mi.

0.025(52/52)

(0.009-0.060) 0.136(4/4)

(0.098-0.187)

NA (0/0)

(NA-NA)

NA (0/0)

(NA-NA) 0 0

Co-60 40 NA ND (0/40)

(ND-ND)

Th-228 40 NA ND (0/40)

(ND-ND)

NA NA NA NA (0/0)

(NA-NA)

(NA-NA)

NA NA (0/0)

(NA-NA)

(NA-NA) 0 0

Fish (pCi/kg wet)

K-40 9

NA 2874(5/5)

(2620-3140)

Sta. 35 2.0 mi.

3088(4/4) 3088(4/4)

(2650-3340)

(2650-3340) 0 Co-60 9

130 ND (0/5)

(ND-ND)

NA NA NA ND (0/4)

(NA-NA)

(ND-ND)

NA ND (0/4)

(NA-NA)

(ND-ND) 0 0

Cs-137 9

IS0 ND (0/5)

(ND-ND)

(I) Nominal Lower Limit of Detection (LLD), as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketsO.

(3) ND - Non Detectable.

(4) NA - Not Applicable.

ENVIRONMENTAL RADIOLOGICAL IONITORING PROGRAM

SUMMARY

Name of Facility Location of Facility Cooper Nuclear Station Nemaha, Nebraska (County. State)

Docket No.

50-298 Reporting Period January I, 2003 to December 31, 2003 Type &

Lower Limit All Indicator Control Medium of Pathway Total No.

of Locations Location with llighest Annual Mean Location No. of Sampled of Analyses Detection (I)

Mean (2)

Name Mean () (2)

Mean ( ) (2)

Reportable (Unit of Measurement)

Performed (LLD)

Range (2)

Range (2)

Range (2)

Occurrences Fish (pCi/kg wet)

Th-228 9

NA ND (0/5)

(ND-ND)

NA NA ND (0/4)

(NA-NA)

(ND-ND) 0 M*lIlk Nearest Producers (pCi/liter) 1-131 K-40 18 1.0 ND(0/18)

(ND-ND) 18 NA 1297(18/18)

(1150-1440) w Ra-226 18 NA ND (0/18)

(ND-ND)

NA Sta. 99(3) 10.3 mi.

NA NA Sta. 99(3) 10.3 mi.

NA NA (0/0)

(NA-NA)

(NA-NA) 1318(13/13)

NA (0/0)

(1150-1440)

(NA-NA)

NA NA (0/0)

(NA-NA)

(NA-NA)

NA NA (0/0)

(NA-NA)

(NA-NA) 1485(2/2)

NA (0/0)

(1390-1580)

(NA-NA) 0 0

0 0

0 Milk Other Producers (pCi/litcr) 1-131 K-40 8

1.0 ND (0/8)

(ND-ND) 8 NA 1430(8/8)

(1250-1640)

Th-228 8

NA ND (0/8)

(ND-ND)

NA NA NA (0/0)

(NA-NA)

(NA-NA) 0 Groundwater (pCi/liter) 11-3 8

2000 ND (0/8)

(ND-ND)

NA NA NA (0/0)

(NA-NA)

(NA-NA) 0 (I) Nominal Lower Limit of Detection (LLD), as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in brackets(.

(3) Station 99 switched from other producer to nearest producer in May, 2003.

(4) ND - Non Detectable.

(5) NA - Not Applieable.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Location of Facility Cooper Nuclear Station Nemaha, Nebraska (County, State)

Docket No.

50-298 Reporting Period January 1,2003 to December 31, 2003 Type &

Lower Limit All Indicator Control Medium of Pathway Total No.

of Locations Location with Hiihest Annual Mean Location No. of Sampled of Analyses Detection (l)

Mean (2)

Name Mean () (2)

Mean () (2)

Reportable (Unit of Measurement)

Performed (LLD)

Range (2)

Range (2)

Range (2)

Occurrences Groundwater (pCi/liter)

K-40 8

NA ND (0/8)

(ND-ND)

NA NA NA (0/0)

(NA-NA)

(NA-NA) 0 River Water (pCiAiter)

H-3 8

2000 ND (0/4)

(ND-ND)

NA NA ND (0/4)

(NA-NA)

(ND-ND) 0 K-40 24 NA 308(1/12)

(NA-NA) 200(1/12)

(NA-NA)

Sta. 35 2.0 mi.

Sta. 28 1.8 mi.

429(1/12) 429(1/12)

(NA-NA)

(NA-NA) 200(1/12)

ND (0/12)

(NA-NA)

(ND-ND) 0 0

Th-228 24 NA Thermoluminescence Dosimeter (mR/Standard Quarter)

Shoreline Sediment (pCi/kg dry)

Gamma Dose Quarterly Be-7 128 NA 9.2(124/124)

(2.4-34.0) 2 NA 228(2/2)

(169-287)

Sta. 7 2.5 mi.

Sta. 28 1.8 mi.

15.2(4/4) 10.8(4/4)

(6.8-34.0)

(5.4-14.1) 228(2/2)

NA (0/0)

(169-287)

(NA-NA) 0 0

K-40 2

NA 17450(2/2)

Sta. 28 1.8 mi.

(16500-18400) 17450(2/2)

(16500-18400)

NA (0/0)

(NA-NA) 0 Cs-137 2

180 56.9(2/2)

(39.0-74.8)

Sta. 28 1.8 mi.

56.9(2/2)

NA (0/0)

(39.0-74.8)

(NA-NA) 0 (1) Nominal Lower Limit of Detection (LLD) as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in brackets0.

(3) ND - Non Detectable.

(4) NA - Not Applicable.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Name of Facility Location of Facility Cooper Nuclear Station Nemaha, Nebraska Docket No.

50-298 Reporting Petiod January 1 2003 to December 31, 2003 (County, State)

Type &

Lower Limit All Indicator Control Medium of Pathway Total No.

of Locations Location with Hiehest Annual Mean Location No. of Sampled of Analyses Detection (I)

Mean (2)

Name Mean ( ) (2)

Mean ( ) (2)

Reportable (Unit of Measurement)

Performed (LLD)

Range (2)

Range (2)

Range (2)

Occurrences Shoreline Sediment (pCi/kg dry)

Ra-226 2

NA 2260(1/2)

(NA-NA)

Sta. 28 1.8 mi.

2260(1/2)

NA (0/0)

(NA-NA)

(NA-NA) 0 Th-228 2

NA 3065(2/2)

(2520-3610)

Sta. 28 1.8 mi.

3065(2/2)

NA (0/0)

(2520-3610)

(NA-NA) 0 w

am (I) Nominal Lower Limit of Detection (LLD) as stated in ODAM.

(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketsO.

(3) ND - Non Detectable.

(4) NA - Not Applicable.

SECTION VII. COMPLETE DATA TABLES 37

vl-I-NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 01 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCIICU.M.)

12/31 01/07 1.OOE+04 CU. FT.

2.33E-02 +/- 4.51E-03 L.T. 1.E-02 01/07 01/15 1.15E+04 CU. FT.

1.89E-02 +/- 3.58E-03 L.T. 2.E-02 01/15 01/21 8.59E+03 CU. FT.

2.65E-02 +/- 4.94E-03 L.T. 1.E-02 01/21 01/28 1.01E+04 CU. FT.

3.30E-02 +/- 4.83E-03 L.T. 1.E-02 01/28 02/04 1.00E+04 CU. FT.

2.36E-02 +/- 4.47E-03 L.T. 2.E-02 02/04 02/11 1.OOE+04 CU. FT.

1.91E-02 +/- 4.09E-03 L.T. 2.E-02 02/11 02/18 1.011E+04 CU. FT.

1.71E-02 +/- 3.69E-03 L.T. 1.E-02 02118 02/25 1.02E+04 CU. FT.

2.25E-02 +/- 4.11E-03 L.T. 7.E-03 02/25 03/04 9.90E+03 CU. FT.

3.38E-02 +/- 4.88E-03 L.T. 1.E-02 03/04 03/11 1.01E+04 CU. FT.

2.36E-02 +/- 4.47E-03 L.T. 3.E-02 03/11 03118 1.OOE+04 CU. FT.

3.09E-02 +/- 4.81E-03 L.T. 2.E-02 03/18 03/25 1.OOE+04 CU. FT.

1.17E-02 +/- 3.44E-03 L.T. 3.E-02 03/25 04/01 9.91E+03 CU. FT.

1.31E-02 +/- 3.55E-03 L.T. 2.E-02 04/01 04/08 1.02E+04 CU. FT.

1.19E-02 +/- 3.81E-03 L.T. 2.E-02 04/08 04/15 1.OOE+04 CU. FT.

1.91 E-02 +/- 4.07E-03 L.T. 7.E-03 04/15 04/22 1.00E+04 CU. FT.

9.86E-03 +/- 3.48E-03 L.T. 1.E-02 04/22 04/29 1.01E+04 CU. FT.

1.71E-02 +/- 3.69E-03 L.T. 4.E-03 04/29 05/06 1.00E+04 CU. FT.

1.45E-02 +/- 3.86E-03 L.T. 2.E-02 05/06 05/13 1.OOE+04 CU. FT.

7.10E-03 +/- 3.27E-03 L.T. 1.E-02 05(13 05/20 1.01E+04 CU. FT.

1.47E-02 +/- 3.80E-03 L.T. 1.E-02 05/20 05/27 1.01E+04 CU. FT.

2.01E-02 +/- 4.05E-03 L.T. 8.E-03 05/27 06/03 1.00E+04 CU. FT.

1.33E-02 +/- 3.77E-03 L.T. 2.E-02 06/03 06/10 1.01E+04 CU. FT.

1.39E-02 +/- 3.43E-03 L.T. 2.E-02 06/10 06/18 1.14E+04 CU. FT.

1.88E-02 +/- 3.68E-03 L.T. 1.E-02 06/18 06/25 9.93E+03 CU. FT.

1.77E-02 +/- 3.81E-03 L.T. 2.E-02 06/25 07/01 8.74E+03 CU. FT.

1.98E-02 +/- 4.61E-03 L.T. 4.E-02

VI-I NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 01 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

w to 07/01 07/08 07/14 07/22 07/29 08105 08/12 08/19 08/25 09/02 09/09 09/16 09/23 09/30 10/07 10/14 10/21 10/28 11/04 11/12 11/19 11/25 12/02 12108 12/16 12/23 07/08 07/14 07/22 07/29 08/05 08/12 08/19 08/25 09/02 09/09 09/16 09/23 09/30 10/07 10/14 10/21 10/28 11/04 11/12 11/19 11/25 12/02 12/08 12/16 12/23 12/30 9.94E+03 8.71 E+03 1.15E+04 1.00E+04 1.01 E+04 1.OOE+04 1.02E+04 8.49E+03 1.1 5E+04 1.OOE+04 1.03E+04 9.75E+03 1.01 E+04 1.01 E+04 9.89E+03 1.02E+04 9.84E+03 9.33E+03 1.1 5E+04 1.OOE+04 8.78E+03 9.85E+03 8.67E+03 1.14E+04 9.97E+03 1.01 E+04 CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

2.45E-02 +/- 4.61E-03 1.63E-02 +/- 4.51E-03 2.15E-02 +/- 4.01E-03 2.61E-02 +/- 4.56E-03 2.53E-02 +/- 4.40E-03 2.40E-02 +/- 4.69E-03 2.07E-02 +/- 4.63E-03 3.01E-02 +/- 5.23E-03 2.64E-02 +/- 4.21E-03 2.69E-02 +/- 4.61E-03 1.97E-02 +/- 4.06E-03 2.02E-02 +/- 4.27E-03 1.73E-02 +/- 3.87E-03 3.12E-02 +/- 4.90E-03 2.60E-02 +/- 4.52E-03 3.69E-02 +/- 5.22E-03 2.38E-02 +/- 4.51E-03 1.65E-02 +/- 4.26E-03 5.38E-02 +/- 5.60E-03 1.69E-02 +/- 4.02E-03 2.33E-02 +/- 4.87E-03 5.59E-02 +/- 6.02E-03 7.03E-02 +/- 7.49E-03 3.39E-02 +/- 4.77E-03 1.78E-02 +/- 4.09E-03 1.77E-02 +/- 3.99E-03 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 9.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. I.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 4.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 9.E-03 L.T. 4.E-02 L.T. 2.E-02 L.T. 8.E-03 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 3.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 02 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCIICU.M.)

(PCI/CU.M.)

12/31 01/07 1.00E+04 CU. FT.

2.58E-02 +/- 4.68E-03 L.T. 1.E-02 01/07 01/15 1.15E+04 CU. FT.

2.51E-02 +/- 4.OOE-03 L.T. 1.E-02 01/15 01/21 8.59E+03 CU. FT.

2.74E-02 +/- 5.OOE-03 L.T. 1.E-02 01/21 01/28 1.02E+04 CU. FT.

4.89E-02 +/- 5.69E-03 L.T. 1.E-02 01/28 02/04 9.96E+03 CU. FT.

2.49E-02 +/- 4.57E-03 L.T. 2.E-02 02/04 02/11 1.01E+04 CU. FT.

2.43E-02 +/- 4.42E-03 L.T. 2.E-02 02/11 02/18 1.01 E+04 CU. FT.

1.96E-02 +/- 3.89E-03 L.T. 1.E-02 02/18 02/25 1.02E+04 CU. FT.

2.28E-02 +/- 4.13E-03 L.T. 7.E-03 02/25 03/04 9.90E+03 CU. FT.

4.24E-02 +/- 5.38E-03 L.T. 1.E-02 03/04 03/11 1.02E+04 CU. FT.

3.26E-02 +/- 5.OOE-03 L.T. 3.E-02 03/11 03/18 1.00E+04 CU. FT.

3.51E-02 +/- 5.06E-03 L.T. 2.E-02 03/18 03/25 1.01E+04 CU. FT.

1.73E-02 +/- 3.87E-03 L.T. 3.E-02 03/25 04/01 9.91 E+03 CU. FT.

1.90E-02 +/- 4.02E-03 L.T. 2.E-02 04/01 04/08 9.97E+03 CU. FT.

8.69E-03 +/- 3.62E-03 L.T. 2.E-02 04/08 04/15 1.01E+04 CU. FT.

2.10E-02 +/- 4.17E-03 L.T. 7.E-03 04/15 04/22 1.00E+04 CU. FT.

9.86E-03 +/- 3.48E-03 L.T. 1.E-02 04/22 04/29 1.02E+04 CU. FT.

1.91E-02 +/- 3.83E-03 L.T. 7.E-03 04/29 05/06 1.00E+04 CU. FT.

1.70E-02 +/- 4.05E-03 L.T. 1.E-02 05/06 05/13 1.01E+04 CU. FT.

1.03E-02 +/- 3.52E-03 L.T. 1.E-02 05/13 05/20 9.98E+03 CU. FT.

1.62E-02 +/- 3.95E-03 L.T. 1.E-02 05/20 05/27 1.01E+04 CU. FT.

2.43E-02 +/- 4.35E-03 L.T. 8.E-03 05/27 06/03 9.96E+03 CU. FT.

1.28E-02 +/- 3.73E-03 L.T. 2.E-02 06/03 06/10 1.02E+04 CU. FT.

1.52E-02 +/- 3.52E-03 L.T. 2.E-02 06110 06/18 1.18E+04 CU. FT.

1.73E-02 +/- 3.49E-03 L.T. 1.E-02 06/18 06/25 1.00E+04 CU. FT.

1.83E-02 +/- 3.84E-03 L.T. 2.E-02 06/25 07/01 8.74E+03 CU. FT.

1.29E-02 +/- 4.06E-03 L.T. 4.E-02

Vll-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 02 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

07/01 07/08 9.95E+03 CU. FT.

2.OOE-02 +/- 4.30E-03 L.T. 3.E-02 07/08 07/14 8.65E+03 CU. FT.

1.66E-02 +/- 4.56E-03 L.T. 2.E-02 07/14 07/22 1.15E+04 CU. FT.

2.38E-02 +/- 4.16E-03 L.T. 2.E-02 07/22 07/29 1.OOE+04 CU. FT.

2.21E-02 +/- 4.29E-03 L.T. 2.E-02 07/29 08/05 1.01E+04 CU. FT.

2.32E-02 +/- 4.26E-03 L.T. 1.E-02 08/05 08/12 1.00E+04 CU. FT.

1.81E-02 +/- 4.30E-03 L.T. 1.E-02 08/12 08/19 1.02E+04 CU. FT.

2.42E-02 +/- 4.85E-03 L.T. 1.E-02 08/19 08/25 8.49E+03 CU. FT.

2.41E-02 +/- 4.81E-03 L.T. 2.E-02 08/25 09/02 1.15E+04 CU. FT.

2.43E-02 +/- 4.08E-03 L.T. 9.E-03 09/02 09109 1.OOE+04 CU. FT.

3.02E-02 +/- 4.82E-03 L.T. 2.E-02 09/09 09/16 1.03E+04 CU. FT.

1.81E-02 +/- 3.94E-03 L.T. 1.E-02 09/16 09/23 9.75E+03 CU. FT.

2.68E-02 +/- 4.72E-03 L.T. 1.E-02 09/23 09/30 1.01E+04 CU. FT.

1.46E-02 +/- 3.66E-03 L.T. 1.E-02 09/30 10/07 1.01 E+04 CU. FT.

3.36E-02 +/- 5.05E-03 L.T. 2.E-02 10/07 10/14 9.91E+03 CU. FT.

3.04E-02 +/- 4.80E-03 L.T. 4.E-02 10/14 10/21 1.02E+04 CU. FT.

5.01E-02 +/- 5.92E-03 L.T. 2.E-02 10/21 10/28 9.78E+03 CU. FT.

2.55E-02 +/- 4.64E-03 L.T. 2.E-02 10/28 11/04 1.03E+04 CU. FT.

1.68E-02 +/- 4.OOE-03 L.T. 2.E-02 11/04 11/12 1.16E+04 CU. FT.

6.03E-02 +/- 5.87E-03 L.T. 9.E-03 11/12 11/19 9.94E+03 CU. FT.

2.51E-02 +/- 4.61E-03 L.T. 4.E-02 11/19 11/25 8.78E+03 CU. FT.

2.70E-02 +/- 5.13E-03 L.T. 2.E-02 11/25 12102 9.88E+03 CU. FT.

5.59E-02 +/- 6.01E-03 L.T. 1.E-02 12/02 12/08 8.64E+03 CU. FT.

4.78E-02 +/- 6.40E-03 L.T. 3.E-02 12/08 12/16 1.15E+04 CU. FT.

2.97E-02 +/- 4.51E-03 L.T. 2.E-02 12/16 12/23 9.97E+03 CU. FT.

2.43E-02 +/- 4.54E-03 L.T. 2.E-02 12/23 12/30 1.01E+04 CU. FT.

2.32E-02 +/- 4.38E-03 L.T. 3.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 03 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

tj3 12/31 01/07 01/15 01/21 01/28 02104 02/11 02118 02/25 03/04 03/11 03/18 03/25 04(01 04/08 04/15 04/22 04/29 05/06 05/13 05/20 05/27 06/03 06/10 06/18 06/25 01/07 01/15 01/21 01/28 02/04 02111 02/18 02/25 03(04 03/11 03/18 03/25 04/01 04(08 04/15 04/22 04/29 05/06 05/13 05/20 05/27 06/03 06/10 06/18 06/25 07/01 1.03E+04 1.12E+04 8.67E+03 1.OOE+04 1.01 E+04 1.00E+04 1.02E+04 1.00E+04 9.80E+03 1.02E+04 1.01 E+04 1.01E+04 9.68E+03 1.01E+04 9.96E+03 1.01 E+04 1.02E+04 9.97E+03 9.97E+03 9.93E+03 1.03E+04 9.92E+03 1.01 E+04 1.14E+04 1.00E+04 8.73E+03 CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

2.73E-02 +/- 4.68E-03 1.97E-02 +/- 3.69E-03 3.06E-02 +/- 5.19E-03 3.57E-02 +/- 5.03E-03 2.87E-02 +/- 4.77E-03 2.01E-02 +/- 4.16E-03 1.62E-02 +/- 3.60E-03 2.35E-02 +/- 4.24E-03 3.56E-02 +/- 5.02E-03 2.55E-02 +/- 4.57E-03 3.33E-02 +/- 4.92E-03 1.41E-02 +/- 3.61E-03 2.39E-02 +/- 4.44E-03 1.02E-02 +/- 3.71E-03 1.57E-02 +/- 3.83E-03 9.91E-03 +/- 3.46E-03 1.74E-02 +/- 3.69E-03 1.44E-02 +/- 3.86E-03 5.79E-03 +/- 3.16E-03 1.94E-02 +/- 4.19E-03 2.30E-02 +/- 4.20E-03 1.31E-02 +/- 3.77E-03 1.47E-02 +/- 3.49E-03 2.14E-02 +/- 3.86E-03 1.67E-02 +/- 3.71E-03 1.93E-02 +/- 4.57E-03 L.T. 1.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. I.E-02 L.T. 7.E-03 L.T. 1.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 7.E-03 L.T. 1.E-02 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 7.E-03 L.T. 2.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 4.E-02

vII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 03 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCIICU.M.)

(PCIICU.M.)

w 07/01 07/08 07/14 07/22 07/29 08/05 08/12 08/19 08/25 09/02 09/09 09/16 09/23 09/30 10107 10/14 10/21 10/28 11/04 11/12 11/19 11/25 12/02 12/08 12/16 12/23 07/08 07/14 07/22 07/29 08/05 08/12 08/19 08/25 09/02 09/09 09/16 09/23 09/30 10/07 10/14 10/21 10/28 11/04 11/12 11/19 11/25 12/02 12/08 12/16 12/23 12130 1.00E+04 8.58E+03 1.15E+04 9.99E+03 1.01E+04 1.01 E+04 1.02E+04 8.58E+03 1.14E+04 1.OOE+04 1.03E+04 9.67E+03 1.02E+04 1.03E+04 9.69E+03 1.01 E+04 9.95E+03 1.03E+04 1.14E+04 1.01 E+04 8.76E+03 9.97E+03 8.49E+03 1.15E+04 1.00E+04 1.02E+04 CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

2.45E-02 +/- 4.59E-03 1.86E-02 +/- 4.74E-03 2.29E-02 +/- 4.1OE-03 2.27E-02 +/- 4.33E-03 2.80E-02 +/- 4.57E-03 2.51E-02 +/- 4.73E-03 2.29E-02 +/- 4.77E-03 2.38E-02 +/- 4.76E-03 2.83E-02 +/- 4.35E-03 2.49E-02 +/- 4.48E-03 2.26E-02 +/- 4.26E-03 2.09E-02 +/- 4.34E-03 1.32E-02 +/- 3.51E-03 3.60E-02 +/- 5.12E-03 3.04E-02 +/- 4.86E-03 5.55E-02 +/- 6.21E-03 2.25E-02 +/- 4.39E-03 1.45E-02 +/- 3.83E-03 4.50E-02 +/- 5.21E-03 2.28E-02 +/- 4.41E-03 2.27E-02 +/- 4.83E-03 4.23E-02 +/- 5.27E-03 3.97E-02 +/- 6.02E-03 3.31E-02 +/- 4.70E-03 1.91 E-02 +/- 4.17E-03 1.79E-02 +/- 3.97E-03 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. I.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 9.E-03 L.T. 2.E-02 L.T. 11.E-02 L.T. I.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 4.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 9.E-03 L.T. 4.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 3.E-02

vl-l NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 04 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

12/31 01/07 1.02E+04 CU. FT.

1.92E-02 +/- 4.17E-03 L.T. 1.E-02 01/07 01/15 1.15E+04 CU. FT.

2.38E-02 +/- 3.91E-03 L.T. 1.E-02 01/15 01/21 8.46E+03 CU. FT.

2.76E-02 +/- 5.07E-03 L.T. I.E-02 01/21 01/28 1.00E+04 CU. FT.

3.36E-02 +/- 4.90E-03 L.T. 8.E-03 01/28 02/04 1.01E+04 CU. FT.

2.68E-02 +/- 4.65E-03 L.T. 2.E-02 02/04 02/11 1.OOE+04 CU. FT.

2.15E-02 +/- 4.26E-03 L.T. 2.E-02 02/11 02/18 1.02E+04 CU. FT.

2.12E-02 +/- 3.98E-03 L.T. 1.E-02 02/18 02/25 1.00E+04 CU. FT.

2.78E-02 +/- 4.53E-03 L.T. 7.E-03 02/25 03104 9.87E+03 CU. FT.

3.87E-02 +/- 5.18E-03 L.T. 2.E-02 03/04 03/11 1.02E+04 CU. FT.

2.41E-02 +/- 4.48E-03 L.T. 3.E-02 03/11 03/18 1.01E+04 CU. FT.

3.37E-02 +/- 4.95E-03 L.T. 2.E-02 03/18 03/25 1.01 E+04 CU. FT.

1.52E-02 +/- 3.71E-03 L.T. 3.E-02 03/25 04/01 1.01 E+04 CU. FT.

1.24E-02 +/- 3.45E-03 L.T. 2.E-02 04/01 04/08 9.73E+03 CU. FT.

9.06E-03 +/- 3.72E-03 L.T. 2.E-02 04/08 04/15 1.00E+04 CU. FT.

2.15E-02 +/- 4.24E-03 L.T. 7.E-03 04/15 04/22 1.OOE+04 CU. FT.

1.14E-02 +/- 3.61E-03 L.T. 1.E-02 04/22 04/29 1.02E+04 CU. FT.

1.94E-02 +/- 3.85E-03 L.T. 4.E-03 04/29 05/06 9.93E+03 CU. FT.

1.52E-02 +/- 3.93E-03 L.T. 2.E-02 05/06 05/13 1.01E+04 CU. FT.

1.05E-02 +/- 3.54E-03 L.T. 1.E-02 05/13 05/20 9.93E+03 CU. FT.

1.30E-02 +/- 3.71E-03 L.T. 1.E-02 05/20 05/27 1.02E+04 CU. FT.

2.13E-02 +/- 4.11E-03 L.T. 8.E-03 05/27 06/03 9.96E+03 CU. FT.

1.37E-02 +/- 3.81E-03 L.T. 2.E-02 06/03 06/10 1.01E+04 CU. FT.

1.41E-02 +/- 3.44E-03 L.T. 2.E-02 06/10 06/18 1.15E+04 CU. FT.

2.08E-02 +/- 3.80E-03 L.T. 1.E-02 06/18 06/25 1.00E+04 CU. FT.

1.39E-02 +/- 3.48E-03 L.T. 2.E-02 06/25 07/01 8.72E+03 CU. FT.

1.75E-02 +/- 4.44E-03 L.T. 4.E-02

VIl-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 04 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

01 07/01 07/08 07/14 07/22 07/29 08105 08/12 08/19 08/25 09/02 09/09 09/16 09/23 09/30 10/07 10/14 10/21 10/28 11/04 11/12 11/19 11/25 12/02 12/08 12/16 12/23 07/08 07/14 07/22 07/29 08/05 08/12 08/19 08/25 09/02 09/09 09/16 09/23 09/30 10/07 10/14 10/21 10/28 11/04 11/12 11/19 11/25 12/02 12/08 12/16 12/23 12/30 1.00E+04 8.57E+03 1.16E+04 9.94E+03 1.01 E+04 1.00E+04 1.02E+04 8.58E+03 1.14E+04 1.00E+04 1.03E+04 9.85E+03 1.01 E+04 1.01 E+04 9.79E+03 1.01 E+04 9.90E+03 1.02E+04 1.14E+04 1.01 E+04 8.77E+03 9.91 E+03 8.56E+03 1.16E+04 9.93E+03 1.02E+04 CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

2.23E-02 +/- 4.44E-03 1.66E-02 +/- 4.58E-03 1.91E-02 +/- 3.84E-03 2.04E-02 +/- 4.19E-03 2.65E-02 +/- 4.48E-03 2.18E-02 +/- 4.55E-03 2.52E-02 +/- 4.91E-03 3.45E-02 +/- 5.48E-03 2.54E-02 +/- 4.18E-03 2.63E-02 +/- 4.57E-03 2.09E-02 +/- 4.14E-03 2.06E-02 +/- 4.27E-03 1.92E-02 +/- 4.01E-03 3.11E-02 +/- 4.90E-03 3.49E-02 +/- 5.12E-03 4.73E-02 +/- 5.81E-03 2.91E-02 +/- 4.84E-03 1.30E-02 +/- 3.74E-03 4.98E-02 +/- 5.45E-03 2.10E-02 +/- 4.29E-03 2.57E-02 +/- 5.04E-03 5.49E-02 +/- 5.96E-03 3.63E-02 +/- 5.79E-03 3.24E-02 +/- 4.64E-03 1.80E-02 +/- 4.12E-03 1.90E-02 +/- 4.06E-03 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 9.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 4.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 9.E-03 L.T. 4.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 3.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 05 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

12131 01/07 1.02E+04 CU. FT.

2.20E-02 +/- 4.36E-03 L.T. 9.E-03 01/07 01/15 1.14E+04 CU. FT.

1.90E-02 +/- 3.60E-03 L.T. 9.E-03 01/15 01/21 8.46E+03 CU. FT.

2.17E-02 +/- 4.64E-03 L.T. 1.E-02 01/21 01/28 1.00E+04 CU. FT.

2.99E-02 +/- 4.67E-03 L.T. 8.E-03 01/28 02/04 1.01E+04 CU. FT.

1.86E-02 +/- 4.10E-03 L.T. 1.E-02 02/04 02/11 1.OOE+04 CU. FT.

1.85E-02 +/- 4.05E-03 L.T. 1.E-02 02/11 02/18 1.02E+04 CU. FT.

1.44E-02 +/- 3.45E-03 L.T. 1.E-02 bt, 02/18 02/25 1.00E+04 CU. FT.

1.76E-02 +/- 3.80E-03 L.T. 7.E-03 a

02/25 03/04 9.86E+03 CU. FT.

2.51E-02 +/- 4.32E-03 L.T. 1.E-02 03/04 03/11 1.02E+04 CU. FT.

2.18E-02 +/- 4.32E-03 L.T. 3.E-02 03/11 03118 1.01 E+04 CU. FT.

2.65E-02 +/- 4.50E-03 L.T. 2.E-02 03/18 03/25 1.01E+04 CU. FT.

1.05E-02 +/- 3.32E-03 L.T. 3.E-02 03/25 04/01 1.01E+04 CU. FT.

1.05E-02 +/- 3.28E-03 L.T. 2.E-02 04/01 04/08 9.73E+03 CU. FT.

1.14E-02 +/- 3.91E-03 L.T. 2.E-02 04/08 04/15 1.00E+04 CU. FT.

1.48E-02 +/- 3.74E-03 L.T. 7.E-03 04/15 04/22 1.00E+04 CU. FT.

7.47E-03 +/- 3.27E-03 L.T. 1.E-02 04/22 04/29 1.02E+04 CU. FT.

1.07E-02 +/- 3.13E-03 L.T. 4.E-03 04/29 05/06 9.93E+03 CU. FT.

1.55E-02 +/- 3.96E-03 L.T. 1.E-02 05/06 05/13 1.01E+04 CU. FT.

7.47E-03 +/- 3.28E-03 L.T. 8.E-03 05/13 05/20 9.93E+03 CU. FT.

1.85E-02 +/- 4.13E-03 L.T. 1.E-02 05/20 05/27 1.03E+04 CU. FT.

2.21E-02 +/- 4.14E-03 L.T. 4.E-03 05/27 06/03 9.81E+03 CU. FT.

1.57E-02 +/- 4.OOE-03 L.T. 2.E-02 06/03 06/10 1.01E+04 CU. FT.

1.45E-02 +/- 3.48E-03 L.T. 2.E-02 06/10 06/18 1.15E+04 CU. FT.

1.76E-02 +/- 3.58E-03 L.T. 7.E-03 06/18 06/25 1.OOE+04 CU. FT.

1.97E-02 +/- 3.94E-03 L.T. 1.E-02 06/25 07/01 8.72E+03 CU. FT.

2.12E-02 +/- 4.72E-03 L.T. 3.E-02

VII-'

NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY -AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 05 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

07101 07/08 1.00E+04 CU. FT.

2.24E-02

  • 4.45E-03 L.T. 2.E-02 07/08 07/14 8.58E+03 CU. FT.

1.81E-02 i 4.70E-03 L.T. 1.E-02 07/14 07/22 1.16E+04 CU. FT.

1.68E-02 i 3.68E-03 L.T. 1.E-02 07/22 07/29 9.94E+03 CU. FT.

2.27E-02 i 4.34E-03 L.T. 1.E-02 07/29 08/05 1.01E+04 CU. FT.

2.53E-02 i 4.40E-03 L.T. 9.E-03 08/05 08/12 1.00E+04 CU. FT.

2.24E-02

  • 4.59E-03 L.T. 8.E-03 08/12 08/19 1.02E+04 CU. FT.

2.26E-02 i 4.75E-03 L.T. 6.E-03 08/19 08/25 8.59E+03 CU. FT.

2.92E-02 i 5.13E-03 L.T. 1.E-02 08/25 09/02 1.14E+04 CU. FT.

2.48E-02 +/- 4.13E-03 L.T. 4.E-03 09/02 09/09 1.00E+04 CU. FT.

2.85E-02 +/- 4.71E-03 L.T. 8.E-03 09/09 09/16 1.03E+04 CU. FT.

1.89E-02 +/- 4.OOE-03 L.T. 8.E-03 09/16 09/23 9.85E+03 CU. FT.

2.27E-02 +/- 4.42E-03 L.T. 5.E-03 09/23 09/30 1.02E+04 CU. FT.

1.60E-02 +/- 3.74E-03 L.T. 5.E-03 09/30 10/07 1.01E+04 CU. FT.

3.08E-02 +/- 4.88E-03 L.T. 1.E-02 10/07 10/14 9.78E+03 CU. FT.

2.99E-02 +/- 4.81E-03 L.T. 2.E-02 10/14 10/21 1.01E+04 CU. FT.

3.61E-02 +/- 5.21E-03 L.T. 1.E-02 10/21 10/28 9.90E+03 CU. FT.

1.98E-02 +/- 4.21E-03 L.T. 1.E-02 10/28 11/04 1.03E+04 CU. FT.

1.10E-02 i 3.55E-03 L.T. 1.E-02 11/04 11/12 1.14E+04 CU. FT.

4.72E-02 +/- 5.32E-03 L.T. 4.E-03 11/12 11/19 1.01E+04 CU. FT.

2.65E-02 +/- 4.65E-03 L.T. 3.E-02 11/19 11/25 8.74E+03 CU. FT.

2.92E-02 +/- 5.28E-03 L.T. 2.E-02 11/25 12/02 9.96E+03 CU. FT.

5.16E-02 +/- 5.77E-03 L.T. 8.E-03 12/02 12/08 8.52E+03 CU. FT.

3.80E-02 +/- 5.91E-03 L.T. 2.E-02 12108 12/16 1.16E+04 CU. FT.

3.37E-02 +/- 4.71E-03 L.T. 1.E-02 12/16 12/23 9.93E+03 CU. FT.

1.77E-02 +/- 4.10E-03 L.T. 2.E-02 12/23 12/30 1.02E+04 CU. FT.

1.83E-02 +/- 4.OOE-03 L.T. 2.E-02

vll-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 06 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCIICU.M.)

(PCI/CU.M.)

co 12/31 01/07 01/15 01/21 01/28 02/04 02/11 02/18 02/25 03/04 03/11 03/18 03/25 04/01 04/08 04(15 04/22 04/29 05/06 05/13 05/20 05/27 06/03 06/10 06/18 06/25 01/07 01/15 01/21 01/28 02104 02/11 02/18 02/25 03/04 03/11 03/18 03/25 04/01 04/08 04/15 04/22 04/29 05/06 05/13 05/20 05/27 06/03 06/10 06/18 06/25 07/01 1.02E+04 1.14E+04 8.46E+03 1.OOE+04 1.01 E+04 1.00E+04 1.02E+04 1.OOE+04 9.87E+03 1.02E+04 1.01 E+04 1.01 E+04 1.01 E+04 9.73E+03 9.98E+03 1.OOE+04 1.02E+04 9.93E+03 1.01 E+04 9.93E+03 1.03E+04 9.86E+03 1.01 E+04 1.15E+04 9.94E+03 8.72E+03 CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

CU. FT.

2.49E-02 i 4.56E-03 2.65E-02 +/- 4.10E-03 2.85E-02 +/- 5.13E-03 3.54E-02 +/- 5.01E-03 2.81E-02 +/- 4.73E-03 2.65E-02 +/- 4.59E-03 1.64E-02 +/- 3.61E-03 2.46E-02 +/- 4.31E-03 3.33E-02 +/- 4.85E-03 3.02E-02 +/- 4.86E-03 3.18E-02 +/- 4.83E-03 1.55E-02 +/- 3.73E-03 1.57E-02 +/- 3.72E-03 2.24E-02 +/- 4.70E-03 2.11E-02 +/- 4.21E-03 8.22E-03 +/- 3.34E-03 1.60E-02 +/- 3.58E-03 1.35E-02 +/- 3.81E-03 7.18E-03 +/- 3.25E-03 1.52E-02 +/- 3.89E-03 1.87E-02 +/- 3.90E-03 1.29E-02 +/- 3.77E-03 1.26E-02 +/- 3.32E-03 1.94E-02 +/- 3.70E-03 1.79E-02 +/- 3.81E-03 1.75E-02 +/- 4.44E-03 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 8.E-03 L.T. 2.E-02 L.T. 7.E-03 L.T. 7.E-03 L.T. 2.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 8.E-03 L.T. 2.E-02 L.T. 1.E-02 L.T. 1.E-02 L.T. 2.E-02 L.T. 1.E-02 L.T. 3.E-02 L.T. 2.E-02 L.T. 2.E-02 L.T. 4.E-02

VlI-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 06 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

07/01 07108 1.00E+04 CU. FT.

2.43E-02 +/- 4.58E-03 L.T. 3.E-02 07/08 07/14 8.58E+03 CU. FT.

1.55E-02 +/- 4.50E-03 L.T. 1.E-02 07/14 07/22 1.16E+04 CU. FT.

1.91E-02 +/- 3.84E-03 L.T. 1.E-02 07/22 07/29 9.94E+03 CU. FT.

2.36E-02 +/- 4.41E-03 L.T. 8.E-03 07/29 08/05 1.01E+04 CU. FT.

2.57E-02 +/- 4.43E-03 L.T. 2.E-02 08/05 08/12 1.00E+04 CU. FT.

2.18E-02 +/- 4.55E-03 L.T. 1.E-02 08112 08/19 1.02E+04 CU. FT.

2.22E-02 +/- 4.72E-03 L.T. 1.E-02 08/19 08/25 8.59E+03 CU. FT.

2.50E-02 +/- 4.84E-03 L.T. 2.E-02 08/25 09/02 1.14E+04 CU. FT.

2.45E-02 +/- 4.12E-03 L.T. 1.E-02 09/02 09/09 1.OOE+04 CU. FT.

2.54E-02 +/- 4.51E-03 L.T. 2.E-02 09/09 09/16 1.03E+04 CU. FT.

1.94E-02 +/- 4.04E-03 L.T. 1.E-02 09/16 09/23 9.86E+03 CU. FT.

2.21E-02 +/- 4.37E-03 L.T. 1.E-02 09/23 09/30 1.02E+04 CU. FT.

1.24E-02 +/- 3.45E-03 L.T. I.E-02 09/30 10/07 1.01E+04 CU. FT.

3.67E-02 +/- 5.22E-03 L.T. 2.E-02 10/07 10/14 9.77E+03 CU. FT.

3.03E-02 +/- 4.83E-03 L.T. 4.E-02 10/14 10/21 1.01E+04 CU. FT.

5.01E-02 +/- 5.95E-03 L.T. 3.E-02 10/21 10/28 9.90E+03 CU. FT.

2.41E-02 +/- 4.52E-03 L.T. 2.E-02 10/28 11/04 1.03E+04 CU. FT.

1.22E-02 +/- 3.65E-03 L.T. 2.E-02 11/04 11/12 1.14E+04 CU. FT.

4.95E-02 +/- 5.43E-03 L.T. 1.E-02 11/12 11/19 1.01E+04 CU. FT.

2.28E-02 +/- 4.41E-03 L.T. 3.E-02 11/19 11/25 8.77E+03 CU. FT.

2.55E-02 +/- 5.03E-03 L.T. 2.E-02 11/25 12/02 9.96E+03 CU. FT.

4.98E-02 +/- 5.68E-03 L.T. 5.E-03 12102 12108 8.51E+03 CU. FT.

3.16E-02 +/- 5.52E-03 L.T. 2.E-02 12108 12/16 1.16E+04 CU. FT.

3.01E-02 +/- 4.50E-03 L.T. 2.E-02 12/16 12/23 9.93E+03 CU. FT.

1.59E-02 +/- 3.97E-03 L.T. 1.E-02 12/23 12/30 1.02E+04 CU. FT.

2.12E-02 +/- 4.21E-03 L.T. 3.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY -AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 07 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

12/31 01/07 1.OOE+04 CU. FT.

1.63E-02 +/- 4.02E-03 L.T. 1.E-02 01/07 01/15 1.15E+04 CU. FT.

1.09E-02 +/- 2.95E-03 L.T. 1.E-02 01/15 01/21 8.59E+03 CU. FT.

1.46E-02 +/- 4.03E-03 L.T. 2.E-02 01/21 01/28 1.02E+04 CU. FT.

3.37E-02 +/- 4.85E-03 L.T. 1.E-02 01/28 02/04 9.96E+03 CU. FT.

2.97E-02 +/- 4.87E-03 L.T. 1.E-02 02/04 02/11 1.01E+04 CU. FT.

3.06E-02 +/- 4.82E-03 L.T. 8.E-03 02/11 02/18 1.01E+04 CU. FT.

1.57E-02 +/- 3.58E-03 L.T. 1.E-02 02/18 02/25 1.02E+04 CU. FT.

2.68E-02 +/- 4.41E-03 L.T. 7.E-03 02/25 03/04 9.90E+03 CU. FT.

3.89E-02 +/- 5.18E-03 L.T. 7.E-03 03/04 03/11 1.02E+04 CU. FT.

3.45E-02 +/- 5.11 E-03 L.T. 2.E-02 03/11 03/18 1.00E+04 CU. FT.

3.96E-02 +/- 5.32E-03 L.T. 3.E-02 03/18 03/25 1.01E+04 CU. FT.

1.76E-02 +/- 3.89E-03 L.T. 2.E-02 03/25 04/01 9.91E+03 CU. FT.

1.85E-02 +/- 3.99E-03 L.T. 3.E-02 04/01 04/08 9.96E+03 CU. FT.

1.30E-02 +/- 3.97E-03 L.T. 2.E-02 04/08 04/15 1.01E+04 CU. FT.

2.39E-02 +/- 4.38E-03 L.T. 1.E-02 04/15 04/22 1.OOE+04 CU. FT.

1.OOE-02 +/- 3.50E-03 L.T. 1.E-02 04/22 04/29 1.02E+04 CU. FT.

1.81E-02 +/- 3.75E-03 L.T. 8.E-03 04/29 05/06 1.00E+04 CU. FT.

1.88E-02 +/- 4.18E-03 L.T. 2.E-02 05/06 05/13 1.01 E+04 CU. FT.

9.52E-03 +/- 3.45E-03 L.T. 1.E-02 05/13 05/20 9.98E+03 CU. FT.

1.53E-02 +/- 3.88E-03 L.T. 1.E-02 05/20 05/27 1.01E+04 CU. FT.

1.60E-02 +/- 3.74E-03 L.T. 2.E-02 05/27 06/03 9.99E+03 CU. FT.

8.89E-03 +/- 3.40E-03 L.T. 1.E-02 06/03 06/10 1.02E+04 CU. FT.

1.44E-02 +/- 3.45E-03 L.T. 3.E-02 06/10 06/18 1.15E+04 CU. FT.

2.17E-02 +/- 3.86E-03 L.T. 2.E-02 06/18 06/25 1.00E+04 CU. FT.

1.42E-02 +/- 3.50E-03 L.T. 2.E-02 06/25 07/01 8.70E+03 CU. FT.

1.48E-02 +/- 4.24E-03 L.T. 4.E-02

Vll-l NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 07 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

07101 07108 9.99E+03 CU. FT.

1.69E-02 +/- 4.07E-03 L.T. 3.E-02 07/08 07/14 8.66E+03 CU. FT.

1.59E-02 +/- 4.50E-03 L.T. 1.E-02 07/14 07/22 1.15E+04 CU. FT.

1.69E-02 +/- 3.70E-03 L.T. 1.E-02 07/22 07/29 1.00E+04 CU. FT.

1.97E-02 +/- 4.12E-03 L.T. 8.E-03 07/29 08/05 1.01E+04 CU. FT.

2.43E-02 +/- 4.33E-03 L.T. 2.E-02 08/05 08/12 1.00E+04 CU. FT.

2.18E-02 +/- 4.55E-03 L.T. 1.E-02 08/12 08/19 1.02E+04 CU. FT.

1.89E-02 +/- 4.51E-03 L.T. 1.E-02 tn 08/19 08/25 8.70E+03 CU. FT.

2.09E-02 +/- 4.50E-03 L.T. 2.E-02 08/25 09/02 1.13E+04 CU. FT.

2.38E-02 +/- 4.10E-03 L.T. 1.E-02 09/02 09/09 1.OOE+04 CU. FT.

1.90E-02 +/- 4.06E-03 L.T. 2.E-02 09/09 09/16 1.03E+04 CU. FT.

2.22E-02 +/- 4.23E-03 L.T. 1.E-02 09/16 09/23 9.75E+03 CU. FT.

2.02E-02 +/- 4.27E-03 L.T. 1.E-02 09/23 09/30 1.01E+04 CU. FT.

1.73E-02 +/- 3.87E-03 L.T. 1.E-02 09/30 10/07 1.01E+04 CU. FT.

3.08E-02 +/- 4.88E-03 L.T. 2.E-02 10/07 10/14 9.89E+03 CU. FT.

2.14E-02 +/- 4.21E-03 L.T. 4.E-02 10/14 10/21 1.01 E+04 CU. FT.

3.25E-02 +/- 5.OOE-03 L.T. 3.E-02 10/21 10/28 9.84E+03 CU. FT.

8.35E-03 +/- 3.31E-03 L.T. 2.E-02 10/28 11/04 1.03E+04 CU. FT.

1.48E-02 +/- 3.85E-03 L.T. 2.E-02 11/04 11/12 1.16E+04 CU. FT.

4.45E-02 +/- 5.13E-03 L.T. 1.E-02 11/12 11/19 9.94E+03 CU. FT.

1.82E-02 +/- 4.13E-03 L.T. 3.E-02 11/19 11/25 8.78E+03 CU. FT.

2.25E-02 +/- 4.81E-03 L.T. 2.E-02 11/25 12102 9.88E+03 CU. FT.

4.55E-02 +/- 5.47E-03 L.T. 9.E-03 12/02 12/08 8.64E+03 CU. FT.

2.88E-02 +/- 5.28E-03 L.T. 2.E-02 12/08 12/16 1.15E+04 CU. FT.

3.39E-02 +/- 4.74E-03 L.T. 2.E-02 12/16 12/23 9.97E+03 CU. FT.

2.12E-02 +/- 4.33E-03 L.T. 2.E-02 12/23 12/30 1.01E+04 CU. FT.

2.03E-02 +/- 4.17E-03 L.T. 3.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 08 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

12/31 01107 1.01E+04 CU. FT.

2.69E-02 + 4.71E-03 L.T. 1.E-02 01/07 01/15 1.14E+04 CU. FT.

2.22E-02 +/- 3.82E-03 L.T. 1.E-02 01/15 01/21 8.58E+03 CU. FT.

2.69E-02

  • 4.97E-03 L.T. 2.E-02 01/21 01/28 1.02E+04 CU. FT.

4.04E-02 + 5.24E-03 L.T. 1.E-02 01/28 02/04 9.91E+03 CU. FT.

2.13E-02 +/- 4.34E-03 L.T. 1.E-02 02/04 02/11 1.01E+04 CU. FT.

1.96E-02 +/- 4.10E-03 L.T. 8.E-03 02/11 02/18 1.02E+04 CU. FT.

1.54E-02 +/- 3.53E-03 L.T. 1.E-02 02/18 02/25 1.00E+04 CU. FT.

2.01E-02 +/- 3.99E-03 L.T. 7.E-03 02/25 03/04 9.90E+03 CU. FT.

3.23E-02 +/- 4.78E-03 L.T. 7.E-03 03/04 03/11 1.02E+04 CU. FT.

2.71E-02 +/- 4.67E-03 L.T. 2.E-02 03/11 03/18 1.00E+04 CU. FT.

3.70E-02 +/- 5.17E-03 L.T. 3.E-02 03/18 03/25 1.01E+04 CU. FT.

1.57E-02 +/- 3.74E-03 L.T. 2.E-02 03/25 04/01 9.93E+03 CU. FT.

1.32E-02 +/- 3.56E-03 L.T. 3.E-02 04/01 04/08 9.97E+03 CU. FT.

1.05E-02 +/- 3.77E-03 L.T. 2.E-02 04/08 04/15 1.00E+04 CU. FT.

1.73E-02 +/- 3.94E-03 L.T. 2.E-02 04/15 04/22 1.00E+04 CU. FT.

1.27E-02

  • 3.72E-03 L.T. 1.E-02 04/22 04/29 1.02E+04 CU. FT.

1.93E-02 +/- 3.84E-03 L.T. 1.E-02 04/29 05/06 1.OOE+04 CU. FT.

1.75E-02 +/- 4.09E-03 L.T. 8.E-03 05/06 05/13 1.01E+04 CU. FT.

5.42E-03 +/- 3.09E-03 L.T. 2.E-02 05/13 05/20 9.98E+03 CU. FT.

1.54E-02 +/- 3.89E-03 L.T. 1.E-02 05/20 05/27 1.02E+04 CU. FT.

2.03E-02 +/- 4.04E-03 L.T. 1.E-02 05/27 06/03 1.OOE+04 CU. FT.

1.58E-02 +/- 3.96E-03 L.T. 1.E-02 06/03 06/10 1.03E+04 CU. FT.

1.44E-02 +/- 3.42E-03 L.T. 3.E-02 06/10 06/18 1.13E+04 CU. FT.

2.03E-02 +/- 3.80E-03 L.T. 2.E-02 06/18 06/25 9.96E+03 CU. FT.

1.92E-02 +/- 3.91E-03 L.T. 2.E-02 06/25 07/01 8.73E+03 CU. FT.

1.71E-02 +/- 4.41E-03 L.T. 4.E-02

VII-'

NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 08 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

07/01 07/08 9.96E+03 CU. FT.

2.38E-02 +/- 4.56E-03 L.T. 3.E-02 07/08 07/14 8.67E+03 CU. FT.

1.46E-02 +/- 4.40E-03 L.T. 1.E-02 07/14 07/22 1.16E+04 CU. FT.

2.02E-02 +/- 3.90E-03 L.T. 1.E-02 07/22 07/29 1.00E+04 CU. FT.

2.29E-02 +/- 4.34E-03 L.T. 8.E-03 07/29 08/05 1.01E+04 CU. FT.

2.34E-02 +/- 4.27E-03 L.T. 2.E-02 08/05 08/12 1.OOE+04 CU. FT.

2.87E-02 +/- 4.98E-03 L.T. 1.E-02 08/12 08/19 1.02E+04 CU. FT.

2.34E-02 +/- 4.79E-03 L.T. 1.E-02 08/19 08/25 8.42E+03 CU. FT.

2.43E-02 +/- 4.85E-03 L.T. 2.E-02 w

08/25 09/02 1.15E+04 CU. FT.

2.62E-02 +/- 4.20E-03 L.T. 1.E-02 09/02 09/09 1.00E+04 CU. FT.

3.76E-02 +/- 5.26E-03 L.T. 2.E-02 09/09 09/16 1.03E+04 CU. FT.

2.04E-02 +/- 4.1 1E-03 L.T. 1.E-02 09/16 09/23 9.72E+03 CU. FT.

2.24E-02 +/- 4.43E-03 L.T. 1.E-02 09/23 09/30 2.60E+03 CU. FT.

1.55E-02 +/- 1.03E-02 L.T. 5.E-02 09/30 10/07 1.03E+04 CU. FT.

2.84E-02 +/- 4.68E-03 L.T. 2.E-02 10/07 10/14 9.76E+03 CU. FT.

2.79E-02 +/- 4.68E-03 L.T. 4.E-02 10/14 10/21 1.01E+04 CU. FT.

4.87E-02 +/- 5.88E-03 L.T. 3.E-02 10/21 10/28 9.84E+03 CU. FT.

2.28E-02 +/- 4.44E-03 L.T. 2.E-02 10/28 11/04 1.OOE+04 CU. FT.

1.17E-02 +/- 3.68E-03 L.T. 2.E-02 11/04 11/12 (a) 11/12 11/19 9.94E+03 CU. FT.

2.33E-02 +/- 4.49E-03 L.T. 3.E-02 11/19 11/25 8.79E+03 CU. FT.

2.50E-02 +/- 4.98E-03 L.T. 2.E-02 11/25 12/02 9.88E+03 CU. FT.

3.43E-02 +/- 4.82E-03 L.T. 5.E-03 12/02 12108 8.62E+03 CU. FT.

2.25E-02 +/- 4.87E-03 L.T. 2.E-02 12/08 12/16 1.16E+04 CU. FT.

3.54E-02 +/- 4.80E-03 L.T. 2.E-02 12/16 12/23 9.96E+03 CU. FT.

1.99E-02 +/- 4.24E-03 L.T. 2.E-02 12/23 12/30 1.63E+03 CU. FT.

4.86E-02 +/- 1.97E-02 L.T. 6.E-02 (a) Sample not available due to pump failure

Vll-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 09 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCIICU.M.)

12/31 01/07 1.01 E+04 CU. FT.

2.72E-02 +/- 4.73E-03 L.T. 1.E-02 01/07 01/15 1.14E+04 CU. FT.

2.25E-02 +/- 3.84E-03 L.T. 1.E-02 01/15 01/21 8.61E+03 CU. FT.

2.51E-02 +/- 4.84E-03 L.T. 2.E-02 01/21 01/28 1.02E+04 CU. FT.

3.85E-02 +/- 5.13E-03 L.T. 1.E-02 01/28 02/04 9.93E+03 CU. FT.

2.74E-02 +/- 4.74E-03 L.T. 1.E-02 02/04 02111 1.01E+04 CU. FT.

2.40E-02 +/- 4.41E-03 L.T. 8.E-03 02111 02118 1.02E+04 CU. FT.

1.80E-02 +/- 3.74E-03 L.T. 1.E-02 02118 02/25 1.01 E+04 CU. FT.

1.99E-02 +/- 3.95E-03 L.T. 7.E-03 02125 03/04 9.85E+03 CU. FT.

4.21E-02 +/- 5.37E-03 L.T. 7.E-03 03/04 03/11 1.02E+04 CU. FT.

2.74E-02 +/- 4.69E-03 L.T. 2.E-02 03/11 03118 1.00E+04 CU. FT.

3.58E-02 +/- 5.10E-03 L.T. 3.E-02 03/18 03/25 1.01E+04 CU. FT.

1.49E-02 +/- 3.68E-03 L.T. 2.E-02 03/25 04/01 1.01 E+04 CU. FT.

1.64E-02 +/- 3.78E-03 L.T. 3.E-02 04/01 04/08 9.76E+03 CU. FT.

1.03E-02 +/- 3.81E-03 L.T. 2.E-02 04/08 04/15 1.00E+04 CU. FT.

2.31E-02 +/- 4.35E-03 L.T. 1.E-02 04/15 04/22 1.00E+04 CU. FT.

7.92E-03 +/- 3.31E-03 L.T. 1.E-02 04/22 04/29 9.96E+03 CU. FT.

1.59E-02 +/- 3.63E-03 L.T. 8.E-03 04/29 05/06 9.93E+03 CU. FT.

1.94E-02 +/- 4.24E-03 L.T. 2.E-02 05/06 05/13 1.01E+04 CU. FT.

6.59E-03 +/- 3.20E-03 L.T. 1.E-02 05/13 05/20 9.99E+03 CU. FT.

1.57E-02 +/- 3.91E-03 L.T. 1.E-02 05/20 05/27 1.02E+04 CU. FT.

2.26E-02 +/- 4.20E-03 L.T. 2.E-02 05/27 06/03 1.00E+04 CU. FT.

1.48E-02 +/- 3.88E-03 L.T. 1.E-02 06/03 06/10 1.03E+04 CU. FT.

1.31E-02 +/- 3.31E-03 L.T. 3.E-02 06/10 06/18 1.13E+04 CU. FT.

2.04E-02 +/- 3.81E-03 L.T. 2.E-02 06/18 06/25 1.OOE+04 CU. FT.

1.94E-02 +/- 3.92E-03 L.T. 2.E-02 06/25 07/01 8.70E+03 CU. FT.

1.65E-02 +/- 4.37E-03 L.T. 4.E-02

VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 09 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

07/01 07/08 1.00E+04 CU. FT.

2.51E-02 +/- 4.63E-03 L.T. 3.E-02 07/08 07/14 8.60E+03 CU. FT.

1.68E-02 +/- 4.60E-03 L.T. 1.E-02 07/14 07/22 1.16E+04 CU. FT.

2.03E-02 +/- 3.91E-03 L.T. 1.E-02 07/22 07/29 9.97E+03 CU. FT.

2.55E-02 +/- 4.52E-03 L.T. 8.E-03 07/29 08/05 1.01E+04 CU. FT.

2.99E-02 +/- 4.70E-03 L.T. 2.E-02 08/05 08/12 1.00E+04 CU. FT.

2.40E-02 +/- 4.69E-03 L.T. 1.E-02 08/12 08/19 1.02E+04 CU. FT.

2.76E-02 +/- 5.04E-03 L.T. I.E-02 08/19 08/25 8.54E+03 CU. FT.

2.54E-02 +/- 4.88E-03 L.T. 2.E-02 08/25 09/02 1.13E+04 CU. FT.

2.64E-02 +/- 4.26E-03 L.T. 1.E-02 09102 09/09 1.OOE+04 CU. FT.

2.66E-02 +/- 4.59E-03 L.T. 2.E-02 09/09 09/16 1.03E+04 CU. FT.

2.25E-02 +/- 4.25E-03 L.T. 1.E-02 09/16 09/23 9.72E+03 CU. FT.

2.14E-02 +/- 4.36E-03 L.T. 1.E-02 09/23 09/30 1.02E+04 CU. FT.

1.85E-02 +/- 3.93E-03 L.T. 1.E-02 09/30 10/07 1.02E+04 CU. FT.

3.79E-02 +/- 5.26E-03 L.T. 2.E-02 10/07 10/14 9.80E+03 CU. FT.

3.03E-02 +/- 4.83E-03 L.T. 4.E-02 10/14 10/21 1.01E+04 CU. FT.

3.73E-02 +/- 5.27E-03 L.T. 3.E-02 10/21 10/28 9.85E+03 CU. FT.

2.37E-02 +/- 4.50E-03 L.T. 2.E-02 10/28 11/04 1.03E+04 CU. FT.

1.12E-02 +/- 3.56E-03 L.T. 2.E-02 11/04 11/12 1.15E+04 CU. FT.

4.52E-02 +/- 5.19E-03 L.T. 1.E-02 11/12 11/19 9.83E+03 CU. FT.

2.60E-02 +/- 4.70E-03 L.T. 3.E-02 11/19 11/25 8.77E+03 CU. FT.

3.39E-02 +/- 5.57E-03 L.T. 2.E-02 11/25 12/02 9.88E+03 CU. FT.

3.35E-02 +/- 4.77E-03 L.T. 8.E-03 12/02 12/08 8.62E+03 CU. FT.

2.99E-02 +/- 5.36E-03 L.T. 2.E-02 12/08 12/16 1.16E+04 CU. FT.

3.52E-02 +/- 4.78E-03 L.T. 2.E-02 12/16 12/23 9.93E+03 CU. FT.

2.10E-02 +/- 4.33E-03 L.T. 2.E-02 12/23 12/30 1.02E+04 CU. FT.

1.82E-02 +/- 3.99E-03 L.T. 3.E-02

vI-l NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 10 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

12/31 01/07 1.01E+04 CU. FT.

2.44E-02 +/- 4.55E-03 L.T. 1.E-02 01/07 01/15 1.15E+04 CU. FT.

2.44E-02 +/- 3.95E-03 L.T. 1.E-02 01/15 01/21 8.58E+03 CU. FT.

2.90E-02 +/- 5.12E-03 L.T. 2.E-02 01/21 01/28 1.02E+04 CU. FT.

3.75E-02 +/- 5.07E-03 L.T. 1.E-02 01/28 02/04 9.97E+03 CU. FT.

1.99E-02 +/- 4.23E-03 L.T. 1.E-02 02/04 02/11 1.01E+04 CU. FT.

2.29E-02 +/- 4.33E-03 L.T. 8.E-03 02/11 02/18 1.01 E+04 CU. FT.

2.36E-02 +/- 4.17E-03 L.T. 1.E-02 02/18 02125 1.02E+04 CU. FT.

2.25E-02 +/- 4.11E-03 L.T. 7.E-03 a

02125 03/04 9.85E+03 CU. FT.

3.71E-02 +/- 5.09E-03 L.T. 7.E-03 03/04 03/11 1.02E+04 CU. FT.

3.06E-02 +/- 4.88E-03 L.T. 2.E-02 03/11 03/18 1.00E+04 CU. FT.

2.72E-02 +/- 4.57E-03 L.T. 3.E-02 03/18 03/25 1.01E+04 CU. FT.

1.39E-02 +/- 3.60E-03 L.T. 1.E-02 03/25 04/01 9.92E+03 CU. FT.

2.11 E-02 +/- 4.17E-03 L.T. 3.E-02 04/01 04/08 1.01E+04 CU. FT.

1.39E-02 +/- 3.99E-03 L.T. 2.E-02 04/08 04/15 1.02E+04 CU. FT.

2.61E-02 +/- 4.49E-03 L.T. I.E-02 04/15 04/22 9.55E+03 CU. FT.

9.23E-03 +/- 3.55E-03 L.T. 2.E-02 04/22 04/29 1.02E+04 CU. FT.

1.42E-02 +/- 3.43E-03 L.T. 8.E-03 04/29 05/06 1.00E+04 CU. FT.

1.81E-02 +/- 4.13E-03 L.T. 2.E-02 05106 05/13 1.01E+04 CU. FT.

9.38E-03 +/- 3.44E-03 L.T. 1.E-02 05/13 05/20 9.98E+03 CU. FT.

1.51E-02 +/- 3.87E-03 L.T. 1.E-02 05/20 05/27 1.01E+04 CU. FT.

1.90E-02 +/- 3.97E-03 L.T. 1.E-02 05/27 06/03 9.97E+03 CU. FT.

1.08E-02 +/- 3.57E-03 L.T. 1.E-02 06/03 06/10 1.02E+04 CU. FT.

1.35E-02 +/- 3.37E-03 L.T. 2.E-02 06/10 06/18 1.15E+04 CU. FT.

2.16E-02 +/- 3.85E-03 L.T. 1.E-02 06/18 06/25 1.OOE+04 CU. FT.

1.41E-02 +/- 3.49E-03 L.T. 1.E-02 06/25 07/01 8.73E+03 CU. FT.

1.98E-02 +/- 4.61E-03 L.T. 3.E-02

VII-l NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 10 COLL.

TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)

(PCI/CU.M.)

07/01 07/08 1.OOE+04 CU. FT.

2.05E-02 +/- 4.32E-03 L.T. 2.E-02 07/08 07/14 8.81E+03 CU. FT.

1.53E-02 +/- 4.40E-03 L.T. 7.E-03 07/14 07/22 1.14E+04 CU. FT.

1.60E-02 +/- 3.66E-03 L.T. 1.E-02 07/22 07/29 1.OOE+04 CU. FT.

2.14E-02 +/- 4.24E-03 L.T. 6.E-03 07/29 08/05 1.01E+04 CU. FT.

2.45E-02 +/- 4.35E-03 L.T. 1.E-02 08/05 08/12 1.OOE+04 CU. FT.

1.99E-02 +/- 4.42E-03 L.T. 5.E-03 08/12 08/19 1.02E+04 CU. FT.

2.28E-02 +/- 4.76E-03 L.T. 9.E-03 08/19 08/25 8.50E+03 CU. FT.

2.42E-02 +/- 4.82E-03 L.T. 1.E-02 08/25 09/02 1.15E+04 CU. FT.

2.30E-02 +/- 4.OOE-03 L.T. 7.E-03 09/02 09/09 1.00E+04 CU. FT.

2.43E-02 +/- 4.44E-03 L.T. 2.E-02 09/09 09/16 1.03E+04 CU. FT.

2.49E-02 +/- 4.42E-03 L.T. 5.E-03 09/16 09/23 9.75E+03 CU. FT.

2.07E-02 +/- 4.30E-03 L.T. 7.E-03 09/23 09/30 1.02E+04 CU. FT.

1.57E-02 +/- 3.72E-03 L.T. 7.E-03 09/30 10/07 1.02E+04 CU. FT.

3.76E-02 +/- 5.25E-03 L.T. 1.E-02 10/07 10/14 9.78E+03 CU. FT.

2.95E-02 +/- 4.78E-03 L.T. 2.E-02 10/14 10/21 1.01E+04 CU. FT.

4.54E-02 +/- 5.71E-03 L.T. 2.E-02 10/21 10/28 9.84E+03 CU. FT.

2.44E-02 +/- 4.55E-03 L.T. 1.E-02 10/28 11/04 7.80E+03 CU. FT.

1.82E-02 +/- 4.98E-03 L.T. 1.E-02 11/04 11/12 1.16E+04 CU. FT.

4.01E-02 +/- 4.91E-03 L.T. 6.E-03 11/12 11/19 9.94E+03 CU. FT.

2.22E-02 +/- 4.42E-03 L.T. 2.E-02 11/19 11/25 8.79E+03 CU. FT.

2.82E-02 +/- 5.20E-03 L.T. 2.E-02 11/25 12/02 9.88E+03 CU. FT.

2.86E-02 +/- 4.45E-03 L.T. 5.E-03 12/02 12/08 8.64E+03 CU. FT.

4.80E-02 +/- 6.41E-03 L.T. 1.E-02 12/08 12/16 1.15E+04 CU. FT.

3.12E-02 +/- 4.59E-03 L.T. 1.E-02 12/16 12/23 9.96E+03 CU. FT.

2.79E-02 +/- 4.77E-03 L.T. 2.E-02 12/23 12/30 1.01E+04 CU. FT.

2.43E-02 +/- 4.45E-03 L.T. 2.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 01 DATE COLLECTED 12/31 - 04/01 04101 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

tn M

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.09E-01 +/- 7.66E-03 L.T. 7.E-03 L.T. 3.E-04 L.T. 5.E-04 L.T. 2.E-03 L.T. 3.E-04 L.T. 8.E-04 L.T. I.E-03 L.T. 9.E-04 L.T. 3.E-03 L.T. 1.E-01 L.T. 3.E-04 L.T. 3.E-04 L.T. 4.E-02 L.T. I.E-03 L.T. I.E-03 L.T. 5.E-03 L.T. 5.E-03 1.33E-01 +/- 1.97E-02 L.T. 2.E-02 L.T. 8.E-04 L.T. I.E-03 L.T. 4.E-03 L.T. 9.E-04 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 6.E-01 L.T. 7.E-04 L.T. 7.E-04 L.T. 2.E-01 L.T. 3.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. I.E-02 1.37E-41 +/- 7.65E-03 L.T. 7.E-03 L.T. 3.E-04 L.T. 5.E-04 L.T. 2.E-03 L.T. 3.E-04 L.T. 7.E-04 L.T. 1.E-03 L.T. 9.E-04 L.T. 3.E-03 L.T. 2.E-01 L.T. 3.E-04 L.T. 3.E-04 L.T. 5.E-02 L.T. I.E-03 L.T. 1.E-03 L.T. 5.E-03 L.T. 5.E-03 7.91E-02 +/- 2.39E-02 L.T. 2.E-02 L.T. 9.E-04 L.T. I.E-03 L.T. 4.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. I.E-02 L.T. I.E-01 L.T. 9.E-04 L.T. 8.E-04 L.T. 8.E-02 L.T. 4.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02

VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 02 DATE COLLECTED 12/31 - 04/01 04101 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.21E-01 +/- 1.37E-02 L.T. 1.E-02 L.T. 6.E-04 L.T. 1.E-03 L.T. 3.E-03 L.T. 6.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. I.E-03 L.T. 5.E-03 L.T. 2.E-01 L.T. 6.E-04 L.T. 5.E-04 L.T. 7.E-02 L.T. 2.E-03 L.T. 2.E-03 L.T. 1.E-02 L.T. 9.E-03 1.24E-01 +/- 2.34E-02 L.T. 2.E-02 L.T. 9.E-04 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 8.E-03 L.T. 7.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 2.E-01 L.T. 4.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 1.E-02 1.21E-01 +/- 6.09E-03 L.T. 2.E-03 L.T. 2.E-04 L.T. 4.E-04 L.T. 1.E-03 L.T. 2.E-04 L.T. 5.E-04 L.T. 7.E-04 L.T. 7.E-04 L.T. 2.E-03 L.T. I.E-41 L.T. 2.E-04 L.T. 2.E-04 L.T. 4.E-02 L.T. 1.E-03 L.T. I.E-03 L.T. 4.E-03 L.T. 4.E-03 9.04E-02 +/- 1.86E-02 L.T. 1.E-02 L.T. 9.E-04 L.T. 1.E-03 L.T. 3.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 1.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 6.E-02 L.T. 4.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 03 DATE COLLECTED 12/31 - 04/01 04/01 - 07/01 07/01 - 09/30 09/30 - 12130 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.06E-01 +/- 1.14E-02 L.T. 3.E-03 L.T. 4.E-04 L.T. 5.E-04 L.T. 2.E-03 L.T. 5.E-04 L.T. 7.E-04 L.T. 1.E-03 L.T. 8.E-04 L.T. 3.E-03 L.T. 9.E-02 L.T. 3.E-04 L.T. 4.E-04 L.T. 4.E-02 L.T. 11.E-03 L.T. I.E-03 L.T. 5.E-03 L.T. 5.E-03 1.41E-01 +/- 1.57E-02 L.T. 1.E-02 L.T. 6.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. 5.E-04 L.T. 2.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 5.E-01 L.T. 6.E-04 L.T. 6.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 9.E-03 1.18E-01 +/- 6.70E-03 L.T. 4.E-03 L.T. 3.E-04 L.T. 4.E-04 L.T. I.E-03 L.T. 2.E-04 L.T. 5.E-04 L.T. 8.E-04 L.T. 7.E-04 L.T. 2.E-03 L.T. 1.E-01 L.T. 2.E-04 L.T. 2.E-04 L.T. 4.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 5.E-03 L.T. 5.E-03 8.97E-02 +/- 1.94E-02 L.T. 2.E-02 L.T. 7.E-04 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-04 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 9.E-03 L.T. 2.E-01 L.T. 6.E-04 L.T. 7.E-04 L.T. 6.E-02 L.T. 4.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 04 DATE COLLECTED 12/31 - 04/01 04/01 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.29E-01 +/- 1.57E-02 L.T. 6.E-03 L.T. 7.E-04 L.T. 9.E-04 L.T. 3.E-03 L.T. 6.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 2.E-01 L.T. 5.E-04 L.T. 6.E-04 L.T. 7.E-02 L.T. 2.E-03 L.T. 2.E-03 L.T. I.E-02 L.T. 9.E-03 1.45E-01 +/- 1.68E-02 L.T. 2.E-02 L.T. 7.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. 7.E-04 L.T. 2.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 5.E-01 L.T. 6.E-04 L.T. 6.E-04 L.T. I.E-01 L.T. 3.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 9.E-03 1.16E-01 +/- 8.54E-03 L.T. 3.E-03 L.T. 4.E-04 L.T. 6.E-04 L.T. 2.E-03 L.T. 4.E-04 L.T. 9.E-04 L.T. 1.E-03 L.T. I.E-03 L.T. 3.E-03 L.T. 2.E-01 L.T. 3.E-04 L.T. 3.E-04 L.T. 6.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 4.E-03 L.T. 6.E-03 8.68E-02 +/- 2.04E-02 L.T. 2.E-02 L.T. 9.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. 8.E-04 L.T. I.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. I.E-01 L.T. 7.E-04 L.T. 8.E-04 L.T. 6.E-02 L.T. 4.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 05 DATE COLLECTED 12/31 - 04/01 04/01 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 8.66E-02 +/- 1.10E-02 L.T. 1.E-02 L.T. 6.E-04 L.T. 9.E-04 L.T. 3.E-03 L.T. 5.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. I.E-03 L.T. 5.E-03 L.T. 2.E-01 L.T. 5.E-04 L.T. 5.E-04 L.T. 6.E-02 L.T. 2.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 8.E-03 1.25E-41 +/- 1.62E-02 L.T. 1.E-02 L.T. 5.E-04 L.T. 1.E-03 L.T. 3.E-03 L.T. 6.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 5.E-01 L.T. 5.E-04 L.T. 5.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 1.E-02 1.25E-01 +/- 8.54E-03 L.T. 7.E-03 L.T. 3.E-04 L.T. 6.E-04 L.T. 2.E-03 L.T. 3.E-04 L.T. 7.E-04 L.T. 1.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 2.E-01 L.T. 3.E-04 L.T. 3.E-04 L.T. 6.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 5.E-03 L.T. 6.E-03 8.28E-02 +/- 2.22E-02 L.T. 2.E-02 L.T. 8.E-04 L.T. 2.E-03 L.T. 3.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 9.E-03 L.T. 1.E-41 L.T. 9.E-04 L.T. 1.E-03 L.T. 6.E-02 L.T. 4.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 06 DATE COLLECTED 12/31 - 04/01 04/01 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.34E-01 +/- 1.28E-02 L.T. 3.E-03 L.T. 4.E-04 L.T. 7.E-04 L.T. 2.E-03 L.T. 4.E-04 L.T. 9.E-04 L.T. 1.E-03 L.T. 1.E-03 L.T. 4.E-03 L.T. I.E-01 L.T. 4.E-04 L.T. 4.E-04 L.T. 5.E-02 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 6.E-03 1.28E-01 +/- 1.82E-02 L.T. I.E-02 L.T. 6.E-04 L.T. 1.E-03 L.T. 3.E-03 L.T. 7.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 5.E-01 L.T. 5.E-04 L.T. 6.E-04 L.T. 2.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02 1.19E-01 +/- 7.80E-03 L.T. 2.E-03 L.T. 2.E-04 L.T. 3.E-04 L.T. 1.E-03 L.T. 2.E-04 L.T. 5.E-04 L.T. 7.E-04 L.T. 6.E-04 L.T. 2.E-03 L.T. 1.E-01 L.T. 2.E-04 L.T. 2.E-04 L.T. 4.E-02 L.T. 9.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. 4.E-03 5.99E-02 +/- 1.63E-02 L.T. I.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 9.E-04 L.T. 2.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 9.E-03 L.T. I.E-01 L.T. 7.E-04 L.T. I.E-03 L.T. 7.E-02 L.T. 4.E-03

  • L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 07 DATE COLLECTED 12/31 - 04t01 04101 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 1.15E-41

  • 1.60E-02 L.T. 1.E-02 L.T. 4.E-04 L.T. 6.E-04 L.T. 2.E-03 L.T. 3.E-04 L.T. 8.E-04 L.T. I.E-03 L.T. 9.E-04 L.T. 3.E-03 L.T. 1.E-41 L.T. 3.E-04 L.T. 3.E-04 L.T. 5.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 5.E-03 7.48E-02 +/- 1.49E-02 L.T. 1.E-02 L.T. 6.E-04 L.T. I.E-03 L.T. 3.E-03 L.T. 5.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 5.E-01 L.T. 5.E-04 L.T. 6.E-04 L.T. I.E-41 L.T. 2.E-03 L.T. 2.E-03 L.T. 9.E-03 L.T. 8.E-03 7.55E-02 +/- 8.69E-03 L.T. 2.E-03 L.T. 3.E-04 L.T. 5.E-04 L.T. 1.E-03 L.T. 3.E-04 L.T. 6.E-04 L.T. 9.E-04 L.T. 8.E-04 L.T. 2.E-03 L.T. 2.E-01 L.T. 3.E-04 L.T. 3.E-04 L.T. 5.E-02 L.T. I.E-03 L.T. 1.E-03 L.T. 4.E-03 L.T. 4.E-03 6.63E-02 +/- 1.24E-02 L.T. 5.E-03 L.T. 5.E-04 L.T. 9.E-04 L.T. 3.E-03 L.T. 8.E-04 L.T. 1.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 8.E-02 L.T. 5.E-04 L.T. 5.E-04 L.T. 4.E-02 L.T. 2.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 1.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 08 DATE COLLECTED 12/31 - 04/01 04/01 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-1 03 RU-106 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 1.38E-01 +/- 1.33E-02 L.T. 8.E-03 L.T. 6.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 6.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 2.E-01 L.T. 5.E-04 L.T. 5.E-04 L.T. 7.E-02 L.T. 3.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. I.E-02 1.08E-01 +/- 1.04E-02 L.T. 8.E-03 L.T. 3.E-04 L.T. 5.E-04 L.T. 2.E-03 L.T. 3.E-04 L.T. 7.E-04 L.T. 8.E-04 L.T. 8.E-04 L.T. 2.E-03 L.T. 2.E-01 L.T. 3.E-04 L.T. 3.E-04 L.T. 6.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 5.E-03 L.T. 4.E-03 1.23E-01 +/- 8.23E-03 L.T. 6.E-03 L.T. 3.E-04 L.T. 4.E-04 L.T. 3.E-03 L.T. 4.E-04 L.T. 1.E-03 L.T. 7.E-04 L.T. 6.E-04 L.T. 2.E-03 L.T. 1.E-01 L.T. 2.E-04 L.T. 2.E-04 L.T. 4.E-02 L.T. 9.E-04 L.T. 9.E-04 L.T. 4.E-03 L.T. 3.E-03 8.23E-02 +/- 1.12E-02 L.T. 5.E-03 L.T. 5.E-04 L.T. 8.E-04 L.T. 2.E-03 L.T. 6.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 1.E-03 L.T. 5.E-03 L.T. 8.E-02 L.T. 5.E-04 L.T. 5.E-04 L.T. 3.E-02 L.T. 2.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 1.E-02

Vl1-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 09 DATE COLLECTED 12/31 - 04/01 04/01 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 C0-58 FE-59 C0-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.87E-01 +/- 2.07E-02 L.T. 1.E-02 L.T. 9.E-04 L.T. I.E-03 L.T. 4.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 3.E-01 L.T. 7.E-04 L.T. 7.E-04 L.T. 9.E-02 L.T. 4.E-03 L.T. 5.E-03 L.T. 1.E-02 L.T. 1.E-02 1.28E-01 +/- 8.89E-03 L.T. 9.E-03 L.T. 4.E-04 L.T. 7.E-04 L.T. 2.E-03 L.T. 5.E-04 L.T. 1.E-03 L.T. 1.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 3.E-01 L.T. 3.E-04 L.T. 4.E-04 L.T. 8.E-02 L.T. 2.E-03 L.T. 1.E-03 L.T. 6.E-03 L.T. 5.E-03 1.31E-01 i+/- 7.51 E-03 L.T. 3.E-03 L.T. 3.E-04 L.T. 4.E-04 L.T. 1.E-03 L.T. 3.E-04 L.T. 5.E-04 L.T. 9.E-04 L.T. 7.E-04 L.T. 2.E-03 L.T. 2.E-01 L.T. 2.E-04 L.T. 2.E-04 L.T. 4.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 4.E-03 L.T. 4.E-03 9.76E-02 +/- 2.66E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. I.E-41 L.T. 5.E-04 L.T. 8.E-04 L.T. 7.E-02 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-02 L.T. 1.E-02

Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)

STATION NUMBER 10 DATE COLLECTED 12/31 - 04101 04101 - 07/01 07/01 - 09/30 09/30 - 12/30 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.33E-01 +/- 1.69E-02 L.T. 9.E-03 L.T. 7.E-04 L.T. I.E-03 L.T. 3.E-03 L.T. 7.E-04 L.T. 1.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 3.E-01 L.T. 6.E-04 L.T. 7.E-04 L.T. 8.E-02 L.T. 3.E-03 L.T. 4.E-03 L.T. I.E-02 L.T. I.E-02 9.50E-02 +/- 1.25E-02 L.T. 9.E-03 L.T. 3.E-04 L.T. 5.E-04 L.T. 2.E-03 L.T. 3.E-04 L.T. 8.E-04 L.T. I.E-03 L.T. 8.E-04 L.T. 3.E-03 L.T. 2.E-41 L.T. 3.E-04 L.T. 3.E-04 L.T. 7.E-02 L.T. 1.E-03 L.T. I.E-03 L.T. 4.E-03 L.T. 5.E-03 1.18E-01 +/- 6.72E-03 L.T. 2.E-03 L.T. 2.E-04 L.T. 3.E-04 L.T. 3.E-03 L.T. 4.E-04 L.T. I.E-03 L.T. 6.E-04 L.T. 5.E-04 L.T. 2.E-03 L.T. 1.E-O1 L.T. 2.E-04 L.T. 2.E-04 L.T. 3.E-02 L.T. 8.E-04 L.T. 8.E.04 L.T. 3.E-03 L.T. 3.E-03 6.97E-02 +/- 2.75E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 4.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 1.E-03 L.T. 1.E-02 L.T. 1.E-01 L.T. 6.E-04 L.T. 5.E-04 L.T. 5.E-02 L.T. 3.E-03 L.T. 4.E-03 L.T. 2.E-02 L.T. 1.E-02

Vll-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION FISH (PCI/KG WET)

STATION NUMBER 28 DATE COLLECTED:

07/16/2003 CARP 07/16/2003 CATFISH 09/17/2003 CARP 09117/2003 CARP Duplicate Sample 09/17/2003 CATFISH GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+02 2.62E+03 i 2.83E+02 L.T. 2.E+01 L.T. 2.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+02 L.T. 2.E+02 L.T. 1.E+01 L.T. 2.E+01 L.T. 2.E+02 L.T. 5.E+01 L.T. 1.E+02 L.T. 4.E+02 L.T. 4.E+02 L.T.

3.06E+03 _

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

1.E+02 2.59E+02 1.E+01 1.E+01 4.E+01 1.E+01 3.E+01 3.E+01 2.E+01 I.E+02 1.E+02 1.E+01 1.E+01 2.E+02 3.E+01 7.E+01 3.E+02 2.E+02 L.T. 4.E+02 2.74E+03 +/- 6.14E+02 L.T. 4.E+01 L.T. 4.E+01 L.T. 1.E+02 L.T. 5.E+01 L.T. 7.E+01 L.T. 8.E+01 L.T. 5.E+01 L.T. 3.E+02 L.T. 4.E+02 L.T. 4.E+01 L.T. 3.E+01 L.T. 6.E+02 L.T. 7.E+01 L.T. 2.E+02 L.T. 8.E+02 L.T. 8.E+02 L.T. 3.E+02 2.81E+03 +/- 5.47E+02 L.T. 3.E+01 L.T. 4.E+01 L.T. 8.E+01 L.T. 3.E+01 L.T. 6.E+01 L.T. 6.E+01 L.T. 4.E+01 L.T. 2.E+02 L.T. 3.E+02 L.T. 3.E+01 L.T. 3.E+01 L.T. 5.E+02 L.T. 6.E+01 L.T. 2.E+02 L.T. 6.E+02 L.T. 6.E+02 L.T. 3.E+02 3.14E+03 +/- 5.91E+02 L.T. 2.E+01 L.T. 3.E+01 L.T. 4.E+01 L.T. 2.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+01 L.T. 2.E+01 L.T. 4.E+02 L.T. 5.E+01 L.T. 1.E+02 L.T. 5.E+02 L.T. 4.E+02

VII-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION FISH (PCI/KG WET)

STATION NUMBER 35 DATE COLLECTED:

07/16/2003 CARP 07/16/2003 CATFISH 09/17/2003 CARP 09/17/2003 CATFISH GAMMA SPECTRUM ANALYSIS:

nh BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+02 2.65E+03 +/- 3.61E+02 L.T. 2.E+01 L.T. 2.E+01 L.T. 5.E+01 L.T. 2.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+01 L.T. 2.E+01 L.T. 3.E+02 L.T. 6.E+01 L.T. 2.E+02 L.T. 5.E+02 L.T. 4.E+02 L.T. 2.E+02 3.34E+03 +/- 3.33E+02 L.T. 2.E+01 L.T. 2.E+01 L.T. 5.E+01 L.T. 2.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 3.E+01 L.T. 2.E+02 L.T. 2.E+02 L.T. 2.E+01 L.T. 2.E+01 L.T. 3.E+02 L.T. 6.E+01 L.T. 1.E+02 L.T. 5.E+02 L.T. 4.E+02 L.T. 4.E+02 3.27E+03 +/- 6.16E+02 L.T. 4.E+01 L.T. 5.E+01 L.T. 1.E+02 L.T. 4.E+01 L.T. 9.E+01 L.T. 9.E+01 L.T. 6.E+01 L.T. 4.E+02 L.T. 4.E+02 L.T. 4.E+01 L.T. 4.E+01 L.T. 6.E+02 L.T. 8.E+01 L.T. 2.E+02 L.T. 8.E+02 L.T. 7.E+02 L.T. 4.E+02 3.09E+03 +/- 7.23E+02 L.T. 4.E+01 L.T. 5.E+01 L.T. I.E+02 L.T. 5.E+01 L.T. 9.E+01 L.T. 9.E+01 L.T. 6.E+01 L.T. 4.E+02 L.T. 4.E+02 L.T. 3.E+01 L.T. 4.E+01 L.T. 6.E+02 L.T. 8.E+01 L.T. 2.E+02 L.T. 8.E+02 L.T. 8.E+02

Vl1-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCIILITER)

STATION NUMBER 61 DATE COLLECTED:

01/07/2003 02/04/2003 03/04/2003 04/01/2003 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 2.E-01 L.T. 2.E-01 L.T. 3.E-01 L.T. 5.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+01 1.24E+03 +/- 6.07E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 4.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+01 L.T. 5.E+01 L.T. 3.E+01 1.19E+03 +/- 7.55E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 6.E+01 L.T. 4.E+01 1.34E+03 +/- 9.23E+01 L.T. 5.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 7.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. I.E+02 L.T. 8.E+01 L.T.

1.19E+03 +/-

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

2.E+01 7.69E+01 2.E+00 2.E+00 5.E+00 3.E+00 5.E+00 4.E+00 2.E+00 2.E+01 3.E+00 2.E+00 3.E+00 1.E+01 3.E+00 1.E+01 5.E+01 4.E+01

Vl1-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 61 DATE COLLECTED:

05/06/2003 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 4.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 K-40 1.25E+03 +/- 8.86E+01 MN-54 L.T. 2.E+00 CO-58 L.T. 2.E+00 FE-59 L.T. 4.E+00 CO-60 L.T. 2.E+00 ZN-65 L.T. 5.E+00 ZR-95 L.T. 4.E+00 RU-103 L.T. 2.E+00 RU-106 L.T. 2.E+01 1-131 L.T. 3.E+00 CS-134 L.T. 2.E+00 CS-137 L.T. 2.E+00 BA-140 L.T. 9.E+00 CE-141 L.T. 3.E+00 CE-144 L.T. 1.E+01 RA-226 L.T. 4.E+01 TH-228 L.T. 4.E+01

VII-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCSIONITER)

STATION NUMBER 99

  • DATE COLLECTED:

05/28/2003 06/10/2003 RADIOCHEMICAL ANALYSIS:

06/10/2003 Duplicate Sample L.T. 3.E-01 06/25/2003 L.T. 5.E-01 1-131 L.T. 7.E-01 L.T. 2.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+01 1.38E+03 + 8.74E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 3.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 6.E+01 L.T. 2.E+01 1.44E+03 +/- 9.16E+01 L.T. 3.E+00 L.T. 2.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 1.E+01 L.T. 3.E+00 L.T. I.E+01 L.T. 4.E+01 L.T. 4.E+01 L.T. 4.E+01 1.43E+03 +/- 1.14E+02 L.T. 5.E+00 L.T. 5.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 1.E+01 L.T. 9.E+00 L.T. 5.E+00 L.T. 4.E+01 L.T. 9.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 2.E+01 L.T. 8.E+00 L.T. 3.E+01 L.T. I.E+02 L.T. I.E+02 L.T. 2.E+01 1.24E+03 +/- 7.33E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 9.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 3.E+01 L.T. 3.E+01

  • Station 99 replaced station 61 as the nearest producer In May. 2003.

Vl1-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 99 DATE COLLECTED:

07/08/2003 07/22/2003 08/05/2003 08/19/2003 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 7.E-01 L.T. 7.E-01 L.T. 8.E-01 L.T. 4.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+01 1.33E+03 +/- 6.85E+01 L.T.. 3.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 8.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 6.E+01 L.T. 6.E+01 L.T. I.E+01 1.35E+03 +/- 5.09E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 7.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 1.40E+03 +/- 7.91E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. I.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 7.E+01 L.T. 4.E+01 1.24E+03 +/- 1.03E+02 L.T. 5.E+00 L.T. 5.E+00 L.T. I.E+01 L.T. 5.E+00 L.T. l.E+01 L.T. 9.E+00 L.T. 5.E+00 L.T. 4.E+01 L.T. 7.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 2.E+01 L.T. 7.E+00 L.T. 3.E+01 L.T. I.E+02 L.T. 9.E+01

Vll-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 99 DATE COLLECTED:

09/02/2003 09/16/2003 10/08/2003 11/04/2003 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 7.E-01 L.T. 3.E-01 L.T. 3.E-01 L.T. 4.E-01 GAMMA SPECTRUM ANALYSIS:

'4 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+01 1.34E+03 +/- 7.47E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 6.E+01 L.T. 6.E+01 L.T. 3.E+01 1.28E+03 +/- 9.49E+01 L.T. 5.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 7.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 6.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 8.E+01 L.T. 2.E+01 1.29E+03 +/- 9.73E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 5.E+01 L.T. 5.E+01 L.T. 4.E+01 1.15E+03 _ 1.48E+02 L.T. 5.E+00 L.T. 4.E+00 L.T. I.E+01 L.T. 4.E+00 L.T. 1.E+01 L.T. 9.E+00 L.T. 5.E+00 L.T. 4.E+01 L.T. 8.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 8.E+00 L.T. 3.E+01 L.T. I.E+02 L.T. I.E+02

Vll-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)

STATION NUMBER 99 DATE COLLECTED:

12/02/2003 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 6.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 K-40 1.26E+03 +/- 7.84E+01 MN-54 L.T. 3.E+00 CO-58 L.T. 2.E+00 FE-59 L.T. 5.E+00 CO-60 L.T. 3.E+00 ZN-65 L.T. 6.E+00 ZR-95 L.T. 4.E+00 RU-103 L.T. 2.E+00 RU-106 L.T. 2.E+01 1-131 L.T. 3.E+00 CS-134 L.T. 2.E+00 CS-137 L.T. 3.E+00 BA-140 L.T. 1.E+01 CE-141 L.T. 4.E+00 CE-144 L.T. 2.E+01 RA-226 L.T. 5.E+01 TH-228 L.T. 5.E+01

Vl1-5 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK OTHER PRODUCERS (PCI/LITER)

STATION NUMBER 99 DATE COLLECTED:

01/07/03 04/08/2003 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 2.E-01 L.T. 8.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 2.E+01 L.T. 3.E+01 K-40 1.58E+03 _ 6.33E+01 1.39E+03 +/- 9.31E+01 MN-54 L.T. 2.E+00 L.T. 4:E+00 CO-58 L.T. 2.E+00 L.T. 4.E+00 FE-59 L.T. 5.E+00 L.T. 1.E+01 CO-60 L.T. 2.E+00 L.T. 5.E+00 ZN-65 L.T. 6.E+00 L.T. 1.E+01 ZR-95 L.T. 4.E+00 L.T. 8.E+00 RU-103 L.T. 2.E+00 L.T. 4.E+00 RU-106 L.T. 2.E+01 L.T. 4.E+01 1-131 L.T. 4.E+00 L.T. 7.E+00 CS-1 34 L.T. 2.E+00 L.T. 4.E+00 CS-137 L.T. 2.E+00 L.T. 4.E+00 BA-140 L.T. 1.E+01 L.T. 2.E+01 CE-141 L.T. 4.E+00 L.T. 6.E+00 CE-144 L.T. 1.E+01 L.T. 3.E+01 RA-226 L.T. 5.E+01 L.T. I.E+02 TH-228 L.T. 4.E+01 L.T. 8.E+01

  • Station 99 replaced station 61 as the nearest producer In May, 2003.

VII-5 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK OTHER PRODUCERS (PCIILITER)

STATION NUMBER 100 DATE COLLECTED:

01/07/03 04/08/03 07/09/2003 10/07/2003 RADIOCHEMICAL ANALYSIS:

1-131 L.T. I.E-01 L.T. 6.E-01 L.T. 6.E-01 L.T. 3.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 C0-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+01 1.48E+03

  • 5.68E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 5.E+00 L.T. 2.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 1.E+01 L.T. 5.E+01 L.T. 4.E+01 L.T. 3.E+01 1.39E+03 +/- 7.67E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 6.E+01 L.T. 3.E+01 1.64E+03 +/- 7.77E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 8.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 8.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 6.E+01 L.T. 4.E+01 1.40E+03 +/- 1.08E+02 L.T. 6.E+00 L.T. 5.E+00 L.T. 1.E+01 L.T. 6.E+00 L.T. 1.E+01 L.T. 9.E+00 L.T. 5.E+00 L.T. 5.E+01 L.T. 8.E+00 L.T. 5.E+00 L.T. 6.E+00 L.T. 2.E+01 L.T. 8.E+00 L.T. 3.E+01 L.T. 1.E+02 L.T. I.E+02

Vll-5 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK OTHER PRODUCERS (PCI/LITER)

STATION NUMBER 102

  • DATE COLLECTED:

07/08/03 10/07/03 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 7.E-01 L.T. 3.E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 3.E+01 L.T. 5.E+01 K-40 1.25E+03 +/- 7.32E+01 1.31E+03 +/- 1.24E+02 MN-54 L.T. 3.E+00 L.T. 7.E+00 CO-58 L.T. 4.E+00 L.T. 7.E+00 FE-59 L.T. 8.E+00 L.T. 2.E+01 CO-60 L.T. 3.E+00 L.T. 7.E+00 ZN-65 L.T. 7.E+00 L.T. 2.E+01 ZR-95 L.T. 6.E+00 L.T. I.E+01 RU-103 L.T. 4.E+00 L.T. 6.E+00 RU-106 L.T. 3.E+01 L.T. 6.E+01 1-131 L.T. 1.E+01 L.T. 9.E+00 CS-134 L.T. 3.E+00 L.T. 6.E+00 CS-137 L.T. 3.E+00 L.T. 7.E+00 BA-140 L.T. 2.E+01 L.T. 3.E+01 CE-141 L.T. 6.E+00 L.T. 8.E+00 CE-144 L.T. 2.E+01 L.T. 3.E+01 RA-226 L.T. 7.E+01 L.T. 1.E+02 TH-228 L.T. 6.E+01 L.T. I.E+02

  • Station 102 replaced station 99 as the other producer in July, 2003.

VII-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER II DATE COLLECTED:

01/28/03 04/15/03 07/14/03 10/14/03 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 2. E-01 L.T. 4. E-01 L.T. 5. E-01 L.T. 4. E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2. E+01 L.T. 7. E+01 L.T. 2. E+00 L.T. 2. E+00 L.T. 5. E+00 L.T. 2. E+00 L.T. 5. E+00 L.T. 4. E+00 L.T. 3. E+00 L.T. 2. E+01 L.T. 3. E+00 L.T. 2. E+00 L.T. 3. E+00 L.T. 1. E+01 L.T. 4. E+00 L.T. 2. E+01 L.T. 6. E+01 L.T. 5. E+01 L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

4. E+01
5. E+01
5. E+00
5. E+00
1. E+01
5. E+00
1. E+01
9. E+00
6. E+00
4. E+01
8. E+00
5. E+00
5. E+00
2. E+01
8. E+00
3. E+01
1. E+02
1. E+02 L.T. 2. E+01 L.T. 7. E+01 L.T. 2. E+00 L.T. 2. E+00 L.T. 5. E+00 L.T. 2. E+00 L.T. 5. E+00 L.T. 4. E+00 L.T. 3. E+00 L.T. 2. E+01 L.T. 4. E+00 L.T. 2. E+00 L.T. 3. E+00 L.T. 1. E+01 L.T. 4. E+00 L.T. 1. E+01 L.T. 5. E+01 L.T. 4. E+01 L.T. 5. E+01 L.T. 1. E+02 L.T. 6. E+00 L.T. 7. E+00 L.T. 1. E+01 L.T. 7. E+00 L.T. 1. E+01 L.T. 1. E+01 L.T. 7. E+00 L.T. 6. E+01 L.T. 1. E+01 L.T. 6. E+00 L.T. 6. E+00 L.T. 3. E+01 L.T. 1. E+01 L.T. 4. E+01 L.T. 2. E+02 L.T. 1. E+02 TRITIUM ANALYSIS:

H-3 L.T. 2. E+02 L.T. 2. E+02 L.T. 2. E+02 L.T. 2. E+02

Vl1-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)

STATION NUMBER 47 DATE COLLECTED:

01/15/03 04/15/03 07/14/03 10/14/03 RADIOCHEMICAL ANALYSIS:

1-131 L.T. 4. E-01 L.T. 4. E-01 L.T. 6. E-01 L.T. 6. E-01 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3. E+01 L.T. 6. E+01 L.T. 3. E+00 L.T. 3. E+00 L.T. 6. E+00 L.T. 3. E+00 L.T. 7. E+00 L.T. 5. E+00 L.T. 3. E+00 L.T. 3. E+01 L.T. 5. E+00 L.T. 3. E+00 L.T. 3. E+00 L.T. 1. E+01 L.T. 4. E+00 L.T. 2. E+01 L.T. 7. E+01 L.T. 6. E+01 L.T. 2. E+01 L.T. 2. E+01 L.T. 3. E+00 L.T. 3. E+00 L.T. 5. E+00 L.T. 3. E+00 L.T. 6. E+00 L.T. 5. E+00 L.T. 3. E+00 L.T. 2. E+01 L.T. 4. E+00 L.T. 3. E+00 L.T. 3. E+00 L.T. 1. E+01 L.T. 4. E+00 L.T. 2. E+01 L.T. 6. E+01 L.T. 5. E+01 L.T. 2. E+01 L.T. 5. E+01 L.T. 2. E+00 L.T. 2. E+00 L.T. 4. E+00 L.T. 2. E+00 L.T. 4. E+00 L.T. 3. E+00 L.T. 2. E+00 L.T. 2. E+01 L.T. 4. E+00 L.T. 2. E+00 L.T. 2. E+00 L.T. 1. E+01 L.T. 3. E+00 L.T. 1. E+01 L.T. 4. E+01 L.T. 4. E+01 L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

4. E+01
4. E+01
4. E+00
4. E+00
2. E+01
8. E+00
2. E+01
8. E+00
5. E+00
3. E+01
1. E+01
4. E+00
4. E+00
3. E+01
7. E+00
3. E+01
8. E+01
8. E+01 TRITIUM ANALYSIS:

H-3 L.T. 8. E+02 L.T. 2. E+02 L.T. 2. E+02 L.T. 2. E+02

VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 28 DATE COLLECTED:

01/07/03 02/04/03 03/04/03 04/01/03 05/06/03 GAMMA SPECTRUM ANALYSIS:

t-4 BE-7 K-40 MN-54 CO-58 FE-59 C0-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 4.E+1 L.T. 1.E+2 L.T. 5.E+0 L.T. 5.E+0 L.T. 1.E+1 L.T. 5.E+0 L.T. 1.E+1 L.T. 9.E+0 L.T. 5.E+0 L.T. 5.E+l L.T. 1.E+1 L.T. 5.E+O L.T. 6.E+0 L.T. 3.E+1 L.T. 8.E+0 L.T. 3.E+1 L.T. 9.E+1 L.T. 9.E+1 L.T. 4.E+1 L.T. I.E+2 L.T. 5.E+0 L.T. 5.E+0 L.T. 9.E+0 L.T. 5.E+0 L.T. I.E+1 L.T. 8.E+0 L.T. 4.E+0 L.T. 4.E+1 L.T. 5.E+0 L.T. 4.E+0 L.T. 5.E+0 L.T. 2.E+1 L.T. 6.E+0 L.T. 3.E+1 L.T. 8.E+1 L.T. 8.E+1 L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

2.E+1 2.E+1 2.E+0 3.E+0 5.E+0 3.E+0 5.E+0 5.E+0 3.E+0 2.E+1 4.E+0 3.E+0 3.E+0 1.E+1 4.E+0 2.E+1 6.E+1 5.E+l L.T. 4.E+1 L.T. 11.E+2 L.T. 4.E+0 L.T. 4.E+0 L.T. 9.E+0 L.T. 5.E+0 L.T. 9.E+0 L.T. 8.E+0 L.T. 5.E+0 L.T. 4.E+1 L.T. 7.E+0 L.T. 4.E+0 L.T. 5.E+0 L.T. 2.E+1 L.T. 6.E+0 L.T. 2.E+1 L.T. 1.E+2 L.T. 8.E+1 L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

L.T.

2.E+1 2.E+1 2.E+0 2.E+0 5.E+0 4.E+0 5.E+0 4.E+0 2.E+0 2.E+1 4.E+0 2.E+0 3.E+0 1.E+1 3.E+0 1.E+1 4.E+1 4.E+1 TRITIUM ANALYSIS:

H-3 01/07 - 03/04 L.T. 2.E+2

Vll-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 28 DATE COLLECTED:

06/03/03 07/01/03 08/05/03 09/02/03 10/06/03 GAMMA SPECTRUM ANALYSIS:

BE-7 L.T. 4.E+1 L.T. 1.E+1 L.T. 3.E+1 L.T. 4.E+1 L.T. 6.E+1 K-40 3.08E+02 +/- 7.41E+01 L.T. 3.E+1 L.T. 8.E+1 L.T. 8.E+1 L.T. 2.E+2 MN-54 L.T. 5.E+0 L.T. 1.E+0 L.T. 4.E+0 L.T. 4.E+O L.T. 7.E+0 CO-58 L.T. 5.E+0 L.T. 2.E+0 L.T. 4.E+0 L.T. 4.E+0 L.T. 7.E+0 FE-59 L.T. 9.E+0 L.T. 3.E+0 L.T. 8.E+0 L.T. 9.E+0 L.T. 2.E+1 CO-60 L.T. 5.E+0 L.T. 1.E+0 L.T. 4.E+0 L.T. 4.E+0 L.T. 7.E+0 ZN-65 L.T. 1.E+1 L.T. 3.E+0 L.T. 8.E+0 L.T. 9.E+0 L.T. 1.E+1 ZR-95 L.T. 7.E+0 L.T. 3.E+0 L.T. 7.E+0 L.T. 8.E+0 L.T. 1.E+1 RU-103 L.T. 5.E+0 L.T. 2.E+0 L.T. 4.E+0 L.T. 5.E+0 L.T. 8.E+0 RU-106 L.T. 4.E+1 L.T. 1.E+1 L.T. 3.E+1 L.T. 4.E+1 L.T. 7.E+1 1-131 L.T. 6.E+0 L.T. 3.E+0 L.T. 5.E+0 L.T. 9.E+O L.T. 1.E+1 CS-1 34 L.T. 4.E+0 L.T. 1.E+0 L.T. 4.E+0 L.T. 4.E+0 L.T. 6.E+0 CS-137 L.T. 5.E+0 L.T. 2.E+0 L.T. 4.E+0 L.T. 5.E+0 L.T. 8.E+0 BA-140 L.T. 2.E+1 L.T. 8.E+0 L.T. 2.E+1 L.T. 2.E+1 L.T. 4.E+1 CE-141 L.T. 7.E+0 L.T. 2.E+0 L.T. 6.E+0 L.T. 8.E+0 L.T. I.E+1 CE-144 L.T. 3.E+1 L.T. 9.E+0 L.T. 3.E+1 L.T. 3.E+1 L.T. 4.E+1 RA-226 L.T. I.E+2 L.T. 3.E+l L.T. 9.E+I L.T. I.E+2 L.T. 2.E+2 TH-228 2.OOE+02 +/- 1.00E+02 L.T. 3.E+1 L.T. 8.E+1 L.T. 9.E+I L.T. I.E+2 TRITIUM ANALYSIS:

04/01 - 06/03 07/01 - 09/02 H-3 L.T. 3.E+2 L.T. 2.E+2

V1l-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 28 DATE COLLECTED:

11/04/03 12/02/03 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-1 34 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+1 L.T. 6.E+1 L.T. 3.E+0 L.T. 2.E+0 L.T. 5.E+0 L.T. 4.E+0 L.T. 5.E+0 L.T. 4.E+0 L.T. 2.E+0 L.T. 2.E+1 L.T. 2.E+0 L.T. 2.E+0 L.T. 2.E+0 L.T. 9.E+0 L.T. 3.E+0 L.T. I.E+1 L.T. 4.E+1 L.T. 4.E+1 L.T. 3.E+l L.T. 4.E+1 L.T. 5.E+0 L.T. 5.E+0 L.T. 2.E+l L.T. I.E+1 L.T. 2.E+1 L.T. 8.E+0 L.T. 5.E+0 L.T. 4.E+1 L.T. 7.E+0 L.T. 4.E+0 L.T. 4.E+0 L.T. 2.E+l L.T. 7.E+0 L.T. 3.E+1 L.T. 8.E+1 L.T. 7.E+1 TRITIUM ANALYSIS:

H-3 10/06 - 12/02 L.T. 2.E+2

Vll-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 35 DATE COLLECTED:

01(07/03 02/04/03 03/04/03 04/01/03 05/06/03 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+1 L.T. 4.E+1 L.T. 3.E+0 L.T. 4.E+0 L.T. 8.E+0 L.T. 4.E+0 L.T. 7.E+0 L.T. 7.E+0 L.T. 4.E+0 L.T. 3.E+1 L.T. 8.E+0 L.T. 3.E+0 L.T. 4.E+0 L.T. 2.E+1 L.T. 6.E+0 L.T. 2.E+1 L.T. 7.E+1 L.T. 7.E+1 L.T. 2.E+l L.T. 2.E+1 L.T. 2.E+0 L.T. 2.E+0 L.T. 4.E+0 L.T. 2.E+0 L.T. 5.E+0 L.T. 4.E+0 L.T. 2.E+0 L.T. 2.E+1 L.T. 4.E+0 L.T. 2.E+0 L.T. 3.E+0 L.T. 1.E+l L.T. 3.E+0 L.T. l.E+l L.T. 4.E+1 L.T. 4.E+1 L.T. 2.E+l L.T. 2.E+1 L.T. 3.E+0 L.T. 2.E+0 L.T. 1.E+1 L.T. 4.E+0 L.T. I.E+1 L.T. 4.E+0 L.T. 2.E+0 L.T. 2.E+1 L.T. 3.E+0 L.T. 2.E+0 L.T. 3.E+0 L.T. I.E+1 L.T. 3.E+0 L.T. 1.E+1 L.T. 5.E+l L.T. 4.E+1 L.T. 3.E+l L.T. 9.E+1 L.T. 4.E+0 L.T. 4.E+0 L.T. 8.E+0 L.T. 4.E+0 L.T. 8.E+0 L.T. 8.E+0 L.T. 4.E+0 L.T. 4.E+1 L.T. 7.E+0 L.T. 4.E+0 L.T. 4.E+0 L.T. 2.E+1 L.T. 6.E+0 L.T. 2.E+1 L.T. 9.E+1 L.T. 7.E+1 L.T. 3.E+1 L.T. 7.E+I L.T. 2.E+0 L.T. 3.E+0 L.T. 5.E+0 L.T. 3.E+0 L.T. 6.E+0 L.T. 4.E+0 L.T. 3.E+0 L.T. 2.E+1 L.T. 5.E+0 L.T. 3.E+0 L.T. 3.E+0 L.T. 1.E+l L.T. 4.E+0 L.T. 2.E+1 L.T. 6.E+l L.T. 5.E+l TRITIUM ANALYSIS:

H-3 01/07 - 03104 L.T. 2.E+2

Vll-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)

STATION NUMBER 35 DATE COLLECTED:

06/03/03 07/01/03 08/05/03 09/02/03 10/06/03 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 5.E+1 L.T. I.E+2 L.T. 6.E+0 L.T. 6.E+0 L.T. 1.E+1 L.T. 6.E+0 L.T. 1.E+1 L.T. 1.E+1 L.T. 5.E+0 L.T. 5.E+1 L.T. 7.E+0 L.T. 5.E+0 L.T. 6.E+0 L.T. 2.E+1 L.T. 7.E+0 L.T. 3.E+1 L.T. 1.E+2 L.T. 1.E+2 L.T. 2.E+1 L.T. 5.E+1 L.T. 2.E+0 L.T. 2.E+0 L.T. 5.E+0 L.T. 2.E+0 L.T. 5.E+0 L.T. 4.E+0 L.T. 3.E+0 L.T. 2.E+1 L.T. 5.E+0 L.T. 2.E+0 L.T. 2.E+0 L.T. 1.E+1 L.T. 4.E+0 L.T. 1.E+1 L.T. 5.E+1 L.T. 4.E+1 L.T. 4.E+1 L.T. 1.E+2 L.T. 5.E+0 L.T. 5.E+0 L.T. 1.E+1 L.T. 5.E+0 L.T. 1.E+1 L.T. 9.E+0 L.T. 4.E+0 L.T. 4.E+1 L.T. 6.E+0 L.T. 5.E+0 L.T. 5.E+0 L.T. 2.E+1 L.T. 6.E+0 L.T. 2.E+1 L.T. I.E+2 L.T. 7.E+1 L.T. 2.E+1 L.T. 9.E+1 L.T. 3.E+0 L.T. 3.E+0 L.T. 6.E+0 L.T. 2.E+0 L.T. 6.E+0 L.T. 5.E+0 L.T. 3.E+0 L.T. 2.E+1 L.T. 5.E+0 L.T. 2.E+0 L.T. 3.E+0 L.T. 2.E+1 L.T. 4.E+0 L.T. 2.E+1 L.T. 6.E+1 L.T. 5.E+1 L.T. 5.E+1 4.29E+02 +/- 6.91E+01 L.T. 6.E+0 L.T. 5.E+0 L.T. I.E+1 L.T. 6.E+0 L.T. 1.E+1 L.T. 1.E+1 L.T. 6.E+0 L.T. 5.E+1 L.T. 9.E+0 L.T. 5.E+0 L.T. 6.E+0 L.T. 3.E+1 L.T. 8.E+0 L.T. 3.E+1 L.T. 1.E+2 L.T. I.E+2 TRITIUM ANALYSIS:

H-3 04/01 - 06/03 L.T. 2.E+2 07/01 - 09/02 L.T. 2.E+2

Vll-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCIILITER)

STATION NUMBER 35 DATE COLLECTED:

11/04/03 12/03/03 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-1 34 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 4.E+1 L.T. 1.E+2 L.T. 4.E+0 L.T. 4.E+0 L.T. 2.E+1 L.T. 1.E+1 L.T. 2.E+1 L.T. 8.E+0 L.T. 4.E+0 L.T. 3.E+1 L.T. 5.E+0 L.T. 4.E+0 L.T. 5.E+0 L.T. 2.E+1 L.T. 6.E+0 L.T. 3.E+1 L.T. 1.E+2 L.T. 9.E+1 L.T. 2.E+1 L.T. 6.E+1 L.T. 2.E+0 L.T. 2.E+0 L.T. 5.E+0 L.T. 2.E+0 L.T. 5.E+0 L.T. 4.E+O L.T. 2.E+0 L.T. 2.E+1 L.T. 2.E+0 L.T. 2.E+0 L.T. 3.E+0 L.T. 8.E+0 L.T. 3.E+0 L.T. 1.E+1 L.T. 4.E+1 L.T. 4.E+1 TRITIUM ANALYSIS:

H-3 10/06-12/02 L.T. 2.E+2

VIl-8 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD millirem/Quarter Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01101-03/31 04101-06/30 07101-09130 10101-01/05 i1 std dev.

TLD 01 9.6 +/- 0.4 12.6 +/- 0.7 8.6 +/- 1.0 2.4 +/- 0.8 8.3 +/- 4.3 02 7.6 +/- 1.7 12.5 +/- 0.0 7.4 +/- 1.8 4.0 +/- 0.9 7.9 +/- 3.5 03 7.6 +/- 1.0 13.7 +/- 1.3 10.7 +/- 0.3 7.6 +/- 1.5 9.9 +/- 2.9 04 10.7 +/- 0.2 14.2 +/- 0.5 9.8 +/- 0.5 3.3 +/- 1.4 9.5 +/- 4.5 05 6.9 +/- 0.7 11.7 +/- 0.0 9.1 +/- 1.4 10.2 +/- 1.0 9.5 +/- 2.0 06 8.0 +/- 0.1 6.8 +/- 0.0 12.3 +/- 1.2 6.9 +/- 1.7 8.5 +/- 2.6 07 7.3 +/- 0.8 12.5 +/- 1.1 34.0 +/- 0.1 6.8 +/- 0.6 15.2 +/- 12.8 08 7.5 +/- 1.0 13.5 +/- 0.3 11.3 +/- 0.3 5.5 +/- 2.9 9.5 +/- 3.6 09 5.9 +/- 0.8 10.6 +/- 0.2 10.6 +/- 0.2 8.3 +/- 0.5 8.9 +/- 2.2 10 6.9 +/- 1.1 8.1 +/- 1.0 9.3 +/- 0.5 6.2 +/- 0.4 7.6 +/- 1.4 0

20 10.5 +/- 2.5 10.2 +/- 0.8 10.7 +/- 1.3 5.5 +/- 1.2 9.2 +/- 2.5 44 10.2 +/- 1.0 9.4 +/- 1.2 13.2 +/- 0.8 10.6 +/- 1.2 10.9 +/- 1.6 56 7.9 +/- 0.5 11.0 +/- 2.6 11.1 +/- 0.3 7.8 +/- 2.2 9.5 +/- 1.8 58 8.6 +/- 0.2 7.6 +/- 0.3 10.9 +/- 0.7 6.3 +/- 1.1 8.4 +/- 1.9 59 9.6 +/- 0.5 6.4 +/- 0.2 11.1 +/- 0.0 6.3 +/- 1.8 8.4 +/- 2.4 66 10.6 +/- 0.6 8.5 +/- 0.7 13.8 +/- 1.6 6.5 +/- 2.1 9.9 +/- 3.1 67 11.9 +/- 1.7 7.6 +/- 0.1 12.4 +/- 1.3 5.7 +/- 2.0 9.4 +/- 3.3 71 12.7 +/- 0.0 7.4 +/- 0.6 13.3 +/- 1.8 5.9 +/- 1.3 9.8 +/- 3.7 79 11.2 +/- 0.9 7.4 +/- 0.5 8.8 +/- 1.0 5.0 +/- 2.0 8.1 +/- 2.6 80 9.2 +/- 1.5 6.7 +/- 0.2 8.5 +/- 0.4 5.0 +/- 0.2 7.4 +/- 1.9 81 12.1 +/- 0.4 6.0 +/- 0.0 12.2 +/- 0.2 6.1 +/- 0.9 9.1 +/- 3.5 82 8.7 +/- 1.7 5.7 +/- 1.0 14.0 +/- 1.0 7.8 +/- 1.1 9.1 +/- 3.5 83 11.5 +/- 1.4 8.5 +/- 0.0 10.8 +/- 0.9 8.0 +/- 1.6 9.7 +/- 1.7 84 12.6 +/- 2.2 9.9 +/- 0.4 10.0 +/- 1.2 11.7 +/- 3.4 11.1 +/- 1.3 85 7.7 +/- 0.1 6.7 +/- 0.1 6.0 +/- 0.5 9.9 +/- 0.9 7.6 +/- 1.7

VlI-8 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD millirem/Quarter Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01/03-04(04 04/04-07/10 07/10-10/02 10/02-01/02

+/- 1 std dev.

TLD 86 11.3 +/- 0.5 87 8.6 +/- 1.1 88 10.8 +/- 0.6 89 9.8 +/- 0.9 90 8.3 +/- 1.3 91 9.6 +/- 1.2 94 12.4 +/- 0.5 7.8 +/- 0.4 6.9 +/- 0.6 6.6 +/- 0.8 10.3 +/- 0.2 8.7 +/- 0.3 7.4 +/- 0.8 8.0 +/- 0.4 10.5 +/- 0.1 8.5 +/- 0.6 6.7 +/- 0.8 7.1 +/-0.2 12.6 +/- 0.4 8.4 +/- 0.3 16.5 +/- 0.4 10.1 +/-0.8 7.5 +/- 1.7 4.4 +/- 1.2 7.4 +/- 0.6 9.5 +/- 0.2 7.6 +/- 0.1 8.6 +/- 0.3 9.9 +/- 1.5 7.9 +/- 0.8 7.1 +/- 2.7 8.7 +/- 1.6 9.8 +/- 1.9 8.3 +/- 1.0 11.4 +/- 3.9 AveragelQuarter Average/Day Range Detection/Total 9.5 +/- 1.9 mrem/91 days 0.104 +/- 0.02 mrem/day (6.5-16.1) mrem/91 days 32/32 9.1 +/- 2.5 0.094 +/- 0.03 (1.3-11.7) 32/32 mreml97 days mrem/day mreml97 days 11.3 +/- 4.8 mreml84 days 0.134 +/- 0.06 mrem/day (6.5-14.2) mrem/84 days 32/32 7.0 +/- 2.2 mreml92 days 0.076 +/- 0.02 mrem/day (8.2-20.6) mreml92 days 32/32

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCIIKG WET)

STATION NUMBER 35 DATE COLLECTED (a)

RADIOCHEMICAL ANALYSIS:

1-131 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-1 06 1-131 CS-134 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No vegetation sampled due to milk sample being available. Vegetation wIl be sampled If milk samples are not available.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCIIKG WET)

STATION NUMBER 96 DATE COLLECTED (a)

RADIOCHEMICAL ANALYSIS:

1-131 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No vegetation sampled due to milk sample being available. Vegetation infl be sampled If milk samples are not available.

VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)

STATION NUMBER 101 DATE COLLECTED (a)

RADIOCHEMICAL ANALYSIS:

1-131 GAMMA SPECTRUM ANALYSIS:

BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No vegetation sampled due to milk sample being available. Vegetation will be sampled if milk samples are not available.

vIl-lo NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE SHORELINE SEDIMENT (PCIIKG DRY)

STATION NUMBER 28 DATE COLLECTED:

05/06103 10/06103 GAMMA SPECTRUM ANALYSIS:

%o BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 2.87E+02 +/- 1.01 E+02 1.84E+04 +/- 3.53E+02 L.T. 1.E+1 L.T. 1.E+1 L.T. 3.E+1 L.T. I.E+1 L.T. 3.E+1 L.T. 3.E+1 L.T. 1.E+1 L.T. 1.E+2 L.T. 3.E+1 L.T. 1.E+1 7.48E+01 +/- 1.12E+01 L.T. 8.E+1 L.T. 3.E+1 L.T. 9.E+1 L.T. 3.E+2 3.61E+03 +/- 2.87E+02 1.69E+02 +/- 1.07E+02 1.65E+04 +/- 3.95E+02 L.T. I.E+1 L.T. 2.E+1 L.T. 4.E+1 L.T. I.E+1 L.T. 4.E+1 L.T. 3.E+1 L.T. 2.E+1 L.T. 1.E+2 L.T. 6.E+l L.T. 1.E+1 3.90E+01 +/- 1.59E+01 L.T. I.E+2 L.T. 3.E+1 L.T. 1.E+2 2.26E+03 +/- 3.93E+02 2.52E+03 +/- 3.18E+02

SECTION VIII. REFERENCES 93

VIII. REFERENCES

1.

Nebraska Public Power District, Cooper Nuclear Station Environmental Radiation Monitoring Program, Annual Report, January 1, 1982-December 31, 1982 (prepared by Teledyne Isotopes).

2.

Nebraska Public Power District, Cooper Nuclear Station Environmental Radiation Monitoring Program, Annual Report, January 1, 1983-December 31, 1983 (prepared by Teledyne Isotopes).

3.

Nebraska Public Power District Cooper Nuclear Station, Environmental Monitoring Program, Annual Report, January 1, 1984 to December 31, 1984. (Prepared by Teledyne Isotopes).

4.

U.S. Department of Energy; EML 440 March 1985; EML-444 April 1989; Environmental Measurements Laboratory, US Department of Energy, New York, New York 10014.

5.

U.S. Environmental Protection Agency; Environmental Radiation Data, Report 35, July -- September 1983, Report 39, July -- September 1985; Report 40, October --

December 1984; Report 41, January -- March 1985. Report 42, April -- June 1985; Report 43, July-September 1985, Report 44-45, October-March 1986; Report 46, April-June 1986; Report 47, July-September 1986; Report 48, October-December 1986; Report 49, January-March 1987.

Environmental Radiation Facility, Montgomery, Alabama.

6.

U.S. Department of Energy; EML 460, October 1, 1986; Environmental Measurements Laboratory, US Department of Energy, New York, New York 10014.

7.

U.S. Nuclear Regulatory Commission, 1975, Regulatory Guide 4.8, Environmental Technical Specifications for Nuclear Power Plants.

8.

U.S. Regulatory Commission, Branch Technical Position, Radiological Monitoring Acceptable Program (November, 1979, Revision 1).

94

APPENDIX A 2003 LAND USE CENSUS A-1

ANNUAL CNS LAND USE CENSUS Conducted July 17, 2003 0-3 miles Cooper Nuclear Station (CNS) Offsite Dose Assessment Manual (ODAM) requires an annual land use census. This census identifies the location of the nearest garden that is greater than 500 square feet in area and yields leafy green vegetables, the nearest milk animal, and the location of the nearest resident in each of the 16 meteorological sectors within 3 miles of CNS.

A land use census was performed on July 17, 2003, in accordance with the CNS ODAM.

The nearest residence was found in sector Q, 0.9 miles from CNS, and the nearest garden was found in sector N, 1.0 miles from CNS.

No milk animals were found within 3 miles of CNS and there was no evidence of potable water use from the Missouri River within three miles downstream of CNS.

A-2

ANNUAL CNS LAND USE CENSUS July 17, 2003 0-3 Miles SECTOR NEAREST RESIDENT Direction NEAREST GARDEN Direction NEAREST in Degrees in Degrees MILK Distance Distance ANIMAL A/N 3.0 Miles 1.00 NONE NA NONE B/NNE NONE NA NONE NA NONE C/NE NONE NA NONE NA NONE D/ENE 1.7 Miles 62.00 NONE NA NONE E/E 1.8 Miles 92.00 2.4 Miles 97.00 NONE F/ESE 2.3 Miles 112.00 2.3 Miles 112.00 NONE G/SE NONE NA NONE NA NONE H/SSE NONE' NA NONE NA NONE J/S NONE NA NONE NA NONE K/SSW NONE NA NONE NA NONE L/SW 1.3 Miles 219.00 1.3 Miles 219.0° NONE M/WSW 1.3 Miles 253.00 1.9 Miles 241.00 NONE N/W 1.0 Miles 265.00 1.0 Miles 265.00 NONE P/WNW 1.7 Miles 299.00 2.4 Miles 293.00 NONE Q/NW 0.9 Miles 307.00 2.9 Miles 313.00 NONE R/NNW 1.9 Miles 339.00 1.9 Miles 339.00 NONE A-3

APPENDIX B

SUMMARY

OF INTERLABORATORY COMPARISONS The Teledyne Brown Engineering ICP report is presented in this section B-1

INTERLABORA TORY COMPARISION PROGRAM The purpose of the Interlaboratory Comparison Program (ICP) is to confirm the accuracy of results produced by Teledyne Brown Engineering.

Samples of various matrices (i.e. soil, water, vegetation, air filters, and milk) are spiked with known amounts of radioactivity by commercial vendors of this service and by departments within the government. TBE participates in four programs. Two are commercial, Analytics Inc. and Environmental Resource Associates (ERA) and two are government sponsored programs, the Department of Energy's (DOE) Environmental Measurements Laboratory (EML) and the Mixed Analyte Performance Evaluation Program (MAPEP).

The MAPEP is administered by DOE's Idaho National Engineering Laboratory. All four programs are blind performance evaluation studies in which samples with known activities are sent to TBE for analysis. Once analyzed, TBE submits the results to the respective agency for evaluation. The results of these evaluations are published in TBE's quarterly and annual QA reports.

The 2003 (ICP) includes all contractually required matrices and analyses we supply to customers.

The US Environmental Protection Agency (EPA) discontinued their Interlaboratory Comparison Program in December 1998. However, on May 1, 2001, accreditation was granted to Environmental Resource Associates' (ERA) RadCheM Proficiency Testing Program to complete the process of replacing the USEEPA-LV Nuclear Radiation Assessment Division program.

The National Institute of Standards and Technology (NIST) is the approval authority for laboratory providers participating in Intercomparison Study Programs; however, at this time, there are no approved laboratories for environmental and/or radiochemical isotope analyses.

Trending graphs are provided in this section for the Analytics and ERA Programs.

B-2

ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 3)

Identification Reported Known Ratio (c)

Month/Year Number Matrix Nuclide Units Value (a) Value (b)

TBE/Analytics Evaluation (d)

March, 2003 E3585-396 Milk E3586-396 Milk E3588-396 AP Sr-89 Sr-90 1-131 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi/L 80 133 pCiUL 11.2 11.8 0.60 0.95 N (1)

A pCU/L pCiUL pCUL pCUL pCiUL pCiUL pCUL pCiUL pCUL pCiUL pCi pCi pCi pCi pCi pCi pci pCi pCi 75 168 243 83 207 49 65 53 114 169 239 348 101 277 66 97 80 152 223 74 173 246 90 200 47 64 47 93 162 224 318 117 259 60 83 61 120 209 1.01 0.97 0.99 0.92 1.04 1.04 1.02 1.13 1.23 1.04 1.07 1.09 0.86 1.07 1.10 1.17 1.31 1.27 1.07 A

A A

A A

A A

A W

A A

A A

A A

A N (2)

W A

E3587-396 Charcoal 1-131 pCi 68 74 0.92 A

June, 2003 E3747-396 Milk Sr-89 Sr-90 pCUL 89 85 pCiUL 20 23 1.05 0.87 A

A E3748-396 Milk E3750-396 AP 1-131 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 Ce-141 Cr-51 Cs-1 34 Cs-1 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCiUL pCU/L pCU/L pCU/L pCiUL pCUL pCUL pCi/L pCUL pCi/L pci pci pCi pCi pCi pci pCi pCi pCi 115 285 266 99 236 106 190 108 208 142 238 239 79 189 71 164 91 155 109 103 283 239 103 230 93 186 99 181 132 248 209 91 202 81 163 87 159 116 1.12 1.01 1.11 0.96 1.03 1.14 1.02 1.09 1.15 1.08 0.96 1.14 0.87 0.94 0.88 1.01 1.05 0.97 0.94 A

A A

A A

A A

A A

A A

A A

A A

A A

A A

B-3

ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 2 OF 3)

Identification Reported Known Ratio (c)

Month/Year Number Matrix Nuclide Units Value (a) Value (b) TBE/Analytics Evaluation (d)

June, 2003 E3749-396 Charcoal 1-131 pCi 78 62 September, 2003 E3898-396 Milk E3899-396 Milk E3901-396 AP Sr-89 Sr-90 1-131 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCUL 45 100 pCUL 13 14 pCUL pCUL pCUL pCUL pCiUL pCiUL pCUL pCUL pCUL pCiUL pCi pCi pC!

pC!

pCi pCi pCi pCi pCi pCi 73 85 220 106 90 96 95 84 187 132 79 227 93 70 80 73 74 143 93 74 86 233 119 88 99 93 79 176 123 77 210 108 79 89 84 71 158 111 1.26 0.45 0.93 0.99 0.99 0.94 0.89 1.02 0.97 1.02 1.06 1.06 1.07 1.03 1.08 0.86 0.89 0.90 0.87 1.04 0.91 0.84 0.86 W

N (1)

A A

A A

A A

A A

A A

A A

A A

A A

A A

A A

A E3900-396 Charcoal 1-131 74 86 November, 2003 E3790-396 Milk E3971-396 Milk Sr-89 Sr-90 1-131 Ce-141 Cr-51 Cs-1 34 Cs-1 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCUL 185 pCU1L 19 pCiUL pCi/L pCVL pCiUL pCiL pCiUL pCVL pCI/L pCiUL pCUL 87 186 287 119 116 111 176 94 190 140 168 17 90 202 280 135 129 111 173 102 197 155 1.10 1.12 A

A 0.97 0.92 1.03 0.88 0.90 1.00 1.02 0.92 0.96 0.90 A

A A

A A

A A

A A

A B-4

ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 3 OF 3)

Identification Reported Known Ratio (c)

MonthlYear Number Matrix Nuclide Units Value (a) Value (b)

TBE/Analytics Evaluation (d)

November, 2003 E3973-396 AP Ce-141 Cr-51 Cs-1 34 Cs-1 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pci pCi pci pci pci pCi pci pci pci 144 203 90 85 80 115 72 121 102 142 198 96 91 78 122 72 139 109 1.01 1.03 0.94 0.93 1.03 0.94 1.00 0.87 0.94 A

A A

A A

A A

A A

E3972-396 Charcoal 1-131 pCi 67 77 0.87 A

(1) Incorrectly calculated. The recalculated March & September Sr-89 results of 138 & 95.8 pC4L, respectively, are acceptable.

The efficiency required for these samples Is different than the effidency for regular samples. NCR 04402 (2) Using only the results from the 1099.2 keVphoton, the Fe-59 would be 71 pC1, which Is acceptable. Coincidental summing occurs only with significant Fe-59 activity levels. Therefore, there Is no Impact on environmental samples. NCR 04-02 (a) Teledyne Brown Engineering reported result.

(b) The Analytics known value Is equal to 100% of the parameter present In the standard as determined bygravirnetric and/or volumetric measurements made during standard preparation.

(c) Ratio of Teledyne Brown Engineering to Analytics results.

(d) Analytics evaluation based on TBElntemal OClimits:A=Acceptable. Reported result falls within ratio limits of 0.80-1.20.

W-Acceptable with waming. Reported resultfalls withn 0.70-0.80or 1.20-1.30. N=NotAcceptable. Reported result fails outside the ratio limits of < 0.70 and : 1.30.

B-5

DOEIEML ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 2)

Identification Reported Known Ratio (c)

Month/Year Number Media Nuclide Units Value (a) Value (b)

TBEIEML Evaluation (d)

March, 2003 QAP 58 AP (QAP 0303)

Co-60 Cs-137 Gr-Beta Mn-54 Sr-90 Bqlfilter 35.9 33.5 Bq/filter 113.7 99.7 Bq/filter 1.6 1.5 Bq/filter 49.4 43.8 Bq/filter 2.4 2.8 1.07 1.14 1.07 1.13 0.86 A

A A

A A

Soil Ac-228 Bi-212 8i-214 Cs-1 37 K-40 Pb-212 Pb-214 Sr-90 Th-234 Vegetation Co-60 Cs-1 37 K-40 Sr-90 Water Co-60 Cs-1 34 Cs-137 Gr-Beta H-3 Sr-90 Bq/kg 70.2 57.06 Bq/kg 72.5 60.6 Bq/kg 76.2 67.0 Bq/kg 1883 1450 Bq/kg 805.7 636 Bqlkg 74.8 57.9 Bq/kg 79.2 71.1 Bq/kg 53.5 64.4 Bq/kg 169.1 127 Bq/kg 14.4 12.1 Bq/kg 522 444 Bqlkg 1360 1120 Bq/kg 498.3 650 Bq/L 252.3 234 Bq/L 31.1 30.5 Bq/L 71.5 63.8 Bq/L 821.3 627.5 Bq/L 418.3 390 Bq/L 3.63 4.34 Bq/filter 54.0 58.0 Bq/filter 53.3 55.1 Bq/filter 1.7 2.058 Bq/filter 51.2 54.8 Bq/filter 3.4 3.89 Bqlkg 517.0 488.0 Bq/kg 70.0 80.3 Bq/kg 2127.0 1973.0 Bq/kg 56.1 53.9 Bq/kg 52.7 50.7 Bqlkg 36.4 34.4 Bq/kg 41.5 35.2 Bqlkg 56.2 50.8 Bq/kg 145.4 116.0 1.23 1.20 1.14 1.30 1.27 1.29 1.11 0.83 1.33 W

W A

N (1)

W W

A A

A 1.19 1.18 1.21 0.77 A

A A

A 1.08 1.02 1.12 1.31 1.07 0.84 0.93 0.97 0.83 0.93 0.87 A

A W

W A

W A

A A

A W

September, 2003 QAP 59 AP (QAP 0309)

Soil Mn-54 Co-60 Sr-90 Cs-137 Gr-Beta K-40 Sr-90 Cs-137 Bi-212 Pb-212 B1-214 Pb-214 Ac-228 Th-234 1.06 0.87 1.08 1.04 1.04 1.06 1.18 1.11 1.25 A

A A

A A

A A

A A

B-6

DOE/EML ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 2 OF 2)

Identification Reported Known Ratio (c)

Month/Year Number Media Nuclide Units Value (a) Value (b)

TBE/EML Evaluation (d)

September, 2003 QAP 59 (QAP 0309)

Water H-3 Co-60 Sr-90 Cs-134 Cs-137 Gr-Beta Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L 511.0 491.0 5.9 62.4 74.9 1663.0 446.3 513.0 7.04 63.0 80.3 1948.0 1.14 0.96 0.84 0.99 0.93 0.85 A

A W

A A

A (1) Inconrect bottle size used. Sample was placed Into a smaller container and recounted. All recount results were acceptable except Bi-212 which was acceptable with warning. Previously analyzed samples were examined and no other incorrectcontalnersizes were noted. NCR 03.07 (a) Teledyne Brown Engineering reported result.

(b) The DOE/EML known value Is equal to 100% of the parameter present In the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.

(c) Ratio of Teledyne Brown Engineering to DOE/EML results.

(d) DOE/EML evaluation: A=acceptable, W-acceptable vwth warning, NWnot acceptable.

B-7

ERA ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 1)

Identification Reported Known MonthlYear Number Media Nuclide Units Value (a) Value (b) Control Limits Evaluation (c)

May, 2003 Rad 53 Water 1-131 H-3 Co-60 Cs-134 Cs-I 37 Sr-89 Sr-90 pCVlL pCVIL pCiIL pCVIL pCVIL pCVL pCVL 13.6 1200 69.9 73.5 165 37.0 23.5 20.8 1250 63.8 75.7 150 31.3 27.4 15.6 - 26.0 678 -1820 55.1 - 72.5 67.0 - 84.4 141 - 159 22.6 -40.0 18.7 - 36.1 NA(1)

A A

A NA (2)

A A

November, 2003 Rad 55 Water 1-131 H-3 Co-60 Cs-1 34 Cs-1 37 Sr-89 Sr-90 Gr-Beta pCVL pCVL pCVL pCVL pCVL pCVL pCVL pCVL 22.2 1630 28.4 21.7 63.6 47.9 9.23 161 28.2 14300 27.7 23.4 64.2 50.4 10.2 168 23.0 - 33.4 11800 - 16800 19.0 - 36.4 14.7 - 32.1 55.5 - 72.9 41.7 - 59.1 1.54 -18.9 124 - 212 NA (3)

NA (3)

A A

A A

A A

.1 (1) The stable Iodine carrier In the sample was unaccounted for In the calculation. When recalculated, the correct result of 20.0 pC1'L was within acceptance criteria. NCR 03-11 (2) Although Cs-1371s evaluatedas N. the TBE/ERA ratio of 1.10falls within limits of0.80 -1.20 andis consideredby TBEas acceptable.

(3) The decay correction did not take Into account the extended count Utme. When recalculated, the correct result of 23.2 was within acceptance criteria. NCR 04-06 Due to recakulatng H-3 to required reporting units, a decimal place was dropped. The correct result of 16300 Is within acceptance criteria. NCR 04.06 (a) Teledyne Brown Engineering reported result.

(b) The ERA known value Is equal to 100% of the parameterpresent In the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.

(c) ERA evaluation: A=acceptable. Reported result falls within the Warning Limits. NA=not acceptable. Reported result falls outside of the Control Umits. CE=check for Error. Reported result falls within the Control LImits and outside of the Warning Umit.

B-8

MAPEP ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 1)

Identification Reported Known MonthiYear Number Media Nuclide Units Value (a) Value (b) Control Limits Evaluation (c)

February, 2003 02-WIO Water Cs-1 34 Cs-137 Co-57 Co-60 Mn-54 Sr-90 Zn-65 Bq/L Bq/L BqlL Bq/L Bq/L Bq/L Bq/L 382.7 329.3 58.17 41.2 35.07 11.70 566 421 329 57 38.2 32.9 12.31 516 294.70 - 547.30 230.30 -427.70 39.90 - 74.10 26.74 -49.66 23.03 - 42.77 8.62 - 16.00 361.20 - 670.80 A

A A

A A

A A

July, 2003 03-Sl0 Soil Cs-1 34 Cs-137 Co-57 Co-60 Mn-54 K-40 Sr-90 Zn-65 Bq/Kg Bq/Kg Bq/Kg Bq/Kg Bq/Kg Bq/Kg Bq/Kg Bq/Kg 204 803 499 427 136 686 651 528 238 832 530 420 137 652 714 490 166.60 - 309.40 582.40 -1081.60 371.00 -689.00 294.00 - 546.00 95.90- 178.10 456.40 - 847.60 499.80 - 928.20 343.00 - 637.00 A

A A

A A

A A

A (a) Teledyne Brown Engineering reported result.

(b) The MAPEPknown value Is equal to 10O% of the parameterpresent In the standard as deterrinedbygravimetricand/or volumetric measurements made during standard preparation.

(c) DOEMAPEP evaluation: A=acceptable, VWacceptable with warning, NWnot acceptable.

B-9

INTERLABORATORY COMPARISON PROGRAM GRAPHS 1-131 IN MILK 120-100-4 w

4) 80 1v
LI a

I 60-

a.

40 20 -W 0

1 T

I* TBE U Analtc Ce-141 IN MILK 1000 -

800-600--

Ia U

400-200 a

a p

a k

1 0

  • T 1* TBE U AnalyticsI Cr-51 IN MILK 1200 1000 I

)

800 600 CL400 w

S 200 P

0A I* TBE U Analytics B-1 0 Cos

INTERLABORATORY COMPARISON PROGRAM GRAPHS Cs-134 IN MILK 300 -

225-150 -

a 5

5 a

75 -

l* TBE

  • Analytics Cs-137 IN MILK 350 -

a i

300 -u 250-a

-K-200 l aii t_

150 - a I

I 0a 100 a

a 50 0c Aa I0 Ir IeC X>

I>P 3r

<5>

B>c 0A I* TBE m An~a~lyics Mn-54 IN MILK 240 -

0 i

L200 160 -A t-120 - 5 a

a 80-40 I

l

  • TBE
  • Analytics B-11
cce,

INTERLABORATORY COMPARISON PROGRAM GRAPHS Fe-59 IN MILK 180 -

160-140 -

a

-(

120 v

-j 100*

5 G

80-60 40aa 20 4I d

ge cO' A

c s I

  • TBE U Analyticsl Zn-65 IN MILK 350 300 -

C 150 -

LI 100 50

-i 200 -

BA 0,J~

r o

rss o

l* TBE

  • Analytiscs Co-60 IN MILK 400 -

350 -

300-250-v U 200 -aA a

150 A

a m-lal o

a as 100 50 -

-* TBE U Analtics B-12 2

INTERLABORATORY COMPARISON PROGRAM GRAPHS Sr-90 IN MILK 80 -

60-40 20 40 20 Ie A

Mr M

D 3

X B

e 3r 0

0

  • TBE
  • Analytics Co-58 in Milk 200 -

160 -

4 120-o 80-40 0

O-l f

  • TBE
  • Analyticsl Sr-89 IN MILK 100 -

80 U

80t I

60 o

40-20 0

0 l TBE

  • Analytcs B-13

INTERLABORATORY COMPARISON PROGRAM GRAPHS Ce-141 IN FILTERS 690 590 -

490-

0.

390-290-I-190a 90

-10

<:,9

<,9 O

c,9

<s9 0,9 c° J

r y

0 3v

  • TBE
  • Analytics Cr-51 IN FILTERS 890 790 -

690 -

o590 m

490-390 H290 19090-

-10

  • TBE
  • Analytics Cs-134 IN FILTERS 170 150 130 co 70-H 50 30

-10

  • TBE
  • Analytics B-14

INTERLABORATORY COMPARISON PROGRAM GRAPHS Cs-137 IN FILTERS 440 O

290-a 0.I 0 140 --

i

5-

-10 I* TBE

  • Analytics l Mn-54 IN FILTERS 190-150 -

I o) 110 0

7 U

a a

I I

70I

^

I 30

-10 l

  • TBE
  • Analytics Fe-59 IN FILTERS 190 -

170 -

150 -

U 130 -

a.

110

-(

90 0

70 -

E I-50 a

30 -

10 U

-10 I

I I

I I

I l TBE

  • Analytics B-1 5

INTERLABORATORY COMPARISON PROGRAM GRAPHS Zn-65 IN FILTERS 290 240 C3 190 I

w 140 -

l 40 a

1 F

90 40

-10 I E

A n l y i 9°

+

5b99 9

p pO OK p

s p

Pe F*+TBE

  • Analyt-ics l Co-60 IN FILTERS 290 240 -

53 190 a 11 o-140-a F

90 a

a 40

-10 I

I I

I I

l* TBE

  • Analytics Co-58 IN FILTERS 240 190

.°a 140 0

90 40

-10 Ik sp I

U IIi a

la I

v I i

U N

N

-3

Il I* TBE

  • Analytics B-16 ClI

INTERLABORATORY COMPARISON PROGRAM GRAPHS 1-131 IN CHARCOAL CARTRIDGE 1000 100 t-------

-U -

g§ 10X I-I 1

0.1 Mar-00 Oct-00 Apr-01 Nov-01 May-02 Dec-02 Jun-03 Jan-04

~*TBE M Anytc Co-60 IN WATER S)

-j 0.

140 -

120 -

100 -

A 80 60-40 20 -

0 Aug-99 Mar-00 II a

U s

Oct-00 Apr-01 Nov-01 May-02

[.TBE MEE Dec-02 Jun-03 Jan-04 Cs-134 IN WATER a)

-J 0.

80 70 60 -

50 ___

40 __

30 ____

20 -

10 0

Aug-99 Mar-00 Oct-00 Apr-01 Nov-01 M

TBE *_ERA lay-02 I _ Dec-02 Jun-03 Jan-04 I

L-

L -

B-17 CI i

~

INTERLABORATORY COMPARISON PROGRAM GRAPHS Cs-1 37 IN WATER 250 200 -

150 i) 100 50 0 -,,

Aug-99 Mar-00 Oct-00 Apr-01 Nov-01 May-02 Dec-02 Jun-03 Jan-04

[*TBE EERA February, 2001 - Analyst error or equipment failure.

Sr-89 IN WATER 40 -__

34-

.4 28-O 22 0.

16 -

10 Dec-99 Jun-00 Nov-00 May-01 Nov-01 May-02 Nov-02 May-03 Nov-03

_1TBE UERA Sr-90 IN WATER 30 -

l 20 -

10-.--

0.10 Dec-99 May-00 Oct-00 Feb-01 Jul-01 Dec-01 May-02 Oct-02 Mar-03 Aug-03 Jan-04

  • tTBE *ERAj B-18 C 1 3

INTERLABORATORY COMPARISON PROGRAM GRAPHS GROSS BETA IN WATER 60 -

50 -

.2 40-O 30 -

20 -

U U

a 10 -

I I

Dec-99 May-00 Oct-00 Feb-01 Jul-01 Dec-01 May-02

  • TBE KERA Oct-02 Mar-03 Aug-03 Jan-04 H-3 IN WATER 100000 10000 1000 a

S a

S (D

-J 0a.

100 10 -

Aug-99 Feb-00 Aug-00 Jan-01 Jul-01 Jan-02

  • TBE EERA Jul-02 Jan-03 Jul-03 Jan-04 1-131 IN WATER 32 28 24

" 20 L

16

% 12 8

4 0

Ap a -

r-01 Nov-01 May-02 Dec-02 l*TBE A

Jun-03 Jan-04 B-19 CI,

APPENDIX C SYNOPSIS OF ANALYTICAL PROCEDURES C-l

ANALYTICAL PROCEDURES SYNOPSIS Appendix C is a synopsis of the analytical procedures performed during 2003 on samples collected for the Nebraska Public Power Nuclear Plant's Radiological Environmental Monitoring Program. All analyses have been mutually agreed upon by Nebraska Public Power District and Teledyne Brown Engineering and include those recommended by the USNRC Branch Technical Position, Rev. 1, November 1979.

ANALYSIS TITLE PAGE Gross Beta Analysis of Air Particulate Samples.....................................

C-3 Determination of Gross Beta Activity in Water Samples.....................................

C-4 Analysis of Samples for Tritium (Liquid Scintillation).....................................

C-5 Analysis of Samples for Strontium-89 and -90.....................................

C-6 Water.....................................

C-6 Milk.....................................

C-6 Soil and Sediment.....................................

C-6 Organic Solids.....................................

C-7 Air Particulates.....................................

C-7 Analysis of Samples for Iodine-131.......................................

C-9 Milk or Water.....................................

C-9 Gamma Spectrometry of Samples.......................................

C-10 Milk or Water.....................................

C-10 Dried Solids other than Soils and Sediment........................................ C-10 Fish.......................................

C-10 Soils and Sediments.....................................

C-10 Charcoal Cartridges (Air Iodine).......................................

C-10 Airborne Particulates.......................................

C-11 Addendum to Gamma Spectrometry Procedure....................................... C-12 Environmental Dosimetry.......................................

C-13 Lower Limit of Detection Formulas.......................................

C-14 C-2

GROSS BETA ANALYSIS OF AIR PARTICULATE SAMPLES Air Particulates After a delay of five or more days, allowing for the radon-222 and radon-220 (thoron) daughter products to decay, the filters are counted in a gas-flow proportional counter. An unused air particulate filter, supplied by the customer, is counted as the blank.

Calculations of the results, the two sigma error and the lower limit of detection (LLD):

RESULT (pCi/m )

=

((S/T) - (B/t))/(2.22 V E)

TWO SIGMA ERROR (pCi/Mi)

=

2((SIT ) + (B/t2))1/ 2/(2.22 V E)

LLD (pCi/mi)

=

4.66(B )/(2.22 V E t) where:

S Gross counts of sample including blank B

=

Counts of blank E

=

Counting efficiency T

=

Number of minutes sample was counted t

=

Number of minutes blank was counted V

=

Sample aliquot size (cubic meters)

C-3

DETERMINATION OF GROSS BETA ACTIVITY IN WATER SAMPLES Introduction The procedures described in this section are used to measure the overall radioactivity of water samples without identifying the radioactive species present. No chemical separation techniques are involved.

One liter of the sample is evaporated on a hot plate. A smaller volume may be used if the sample has a significant salt content as measured by a conductivity meter. If requested by the customer, the sample is filtered through No. 54 filter paper before evaporation, removing particles greater than 30 microns in size.

After evaporating to a small volume in a beaker, the sample is rinsed into a 2-inch diameter stainless steel planchette which is stamped with a concentric ring pattern to distribute residue evenly. Final evaporation to dryness takes place under heat lamps.

Residue mass is determined by weighing the planchette before and after mounting the sample. The planchette is counted for beta activity on an automatic proportional counter. Results are calculated using empirical self-absorption curves which allow for the change in effective counting efficiency caused by the residue mass.

Detection Capability Detection capability depends upon the sample volume actually represented on the planchette, the background and the efficiency of the counting instrument, and upon self-absorption of beta particles by the mounted sample. Because the radioactive species are not identified, no decay corrections are made and the reported activity refers to the counting time.

The minimum detectable level (MDL) for water samples is nominally 1.6 picoCuries per liter for gross beta at the 4.66 sigma level (1.0 pCi/L at the 2.83 sigma level), assuming that 1 liter of sample is used and that 1/2 gram of sample residue is mounted on the planchette. These figures are based upon a counting time of 50 minutes and upon representative values of counting efficiency and background of 0.2 and 1.2 cpm, respectively The MDL becomes significantly lower as the mount weight decreases because of reduced self-absorption. At a zero mount weight, the 4.66 sigma MDL for gross beta is 0.9 picoCuries per liter. These values reflect a beta counting efficiency of 0.38.

C-4

ANALYSIS OF SAMPLES FOR TRITIUM (Liquid Scintillation)

Water Ten milliliters of water are mixed with 10 ml of a liquid scintillation "cocktail" and then the mixture is counted in an automatic liquid scintillator.

Calculation of the results, the two sigma error and the lower limit detection (LLD) in pCi/L:

RESULT TWO SIGMA ERROR LLD where:

N B

2.22 V

E At

=

(N-B)/(2.22 V E)

=

2((N + B)/At) / (2.22 V E)

=

4.66(B/At) /(2.22 V E )

the gross cpm of the sample

=

the background of the detector in cpm

=

conversion factor changing dpm to pCi volume of the sample in ml

=

efficiency of the detector counting time for the sample C-5

ANALYSIS OF SAMPLES FOR STRONTIUM-89 AND -90 Water Stable strontium carrier is added to I liter of sample and the volume is reduced by evaporation. Strontium is precipitated as Sr(NO3)2 using nitric acid. A barium scavenge and an iron (ferric hydroxide) scavenge are performed followed by addition of stable yttrium carrier and a minimum of 5 day period for yttrium ingrowth. Yttrium is then precipitated as hydroxide, dissolved and re-precipitated as oxalate. The yttrium oxalate is mounted on a nylon planchette and is counted in a low level beta counter to infer Sr-90 activity. Strontium-89 activity is determined by precipitating SrCO3 from the sample after yttrium separation. This precipitate is mounted on a nylon planchette and is covered with an 80 mg/cm2 aluminum absorber for low level beta counting.

Milk Stable strontium carrier is added to I liter of sample and the sample is first evaporated, then ashed in a muffle furnace.

The ash is dissolved and strontium is precipitated as phosphate, then is dissolved and precipitated as SrNO3 using fuming (90%) nitric acid. A barium chromate scavenge and an iron (ferric hydroxide) scavenge are then performed. Stable yttrium carrier is added and the sample is allowed to stand for a minimum of 5 days for yttrium ingrowth. Yttrium is then precipitated as hydroxide, dissolved and then re-precipitated as oxalate. The yttrium oxalate is mounted on a nylon planchette and is counted in a low level beta counter to infer Sr-90 activity. Strontium-89 is determined by precipitating SrCO3 from the sample after yttrium separation. This precipitate is mounted on a nylon planchette and is covered with an 80 mg/cm2 aluminum absorber for low level beta counting.

Soil and Sediment The sample is first dried under heat lamps and an aliquot is taken.

Stable strontium carrier is added and the sample is leached in hydrochloric acid. The mixture is filtered and strontium is precipitated from the liquid portion as phosphate. Strontium is precipitated as Sr(NO3)2 using fuming (90%) nitric acid. A barium chromate scavenge and an iron (ferric hydroxide) scavenge are then performed. Stable yttrium carrier is added and the sample is allowed to stand for a minimum of 5 days for yttrium ingrowth.

Yttrium is then precipitated as hydroxide, dissolved and re-precipitated as oxalate. The yttrium oxalate is mounted on a nylon planchette and is counted in a low level beta counter to infer Sr-90 activity. Strontium-89 is determined by precipitating SrCO3 from the sample after yttrium separation. This precipitate is mounted on a nylon planchette and is covered with an 80 mg/cm2 aluminum absorber for low level beta counting.

C-6

Organic Solids A wet portion of the sample is dried and then ashed in a muffle furnace. Stable strontium carrier is added and the ash is leached in hydrochloric acid. The sample is filtered and strontium is precipitated from the liquid portion as phosphate. Strontium is precipitated as Sr(NO3)2 using fuming (90%) nitric acid. An iron (ferric hydroxide) scavenge is performed, followed by addition of stable yttrium carrier and a minimum of 5 days period for yttrium ingrowth. Yttrium is then precipitated as hydroxide, dissolved and re-precipitated as oxalate. The yttrium oxalate is mounted on a nylon planchette and is counted in a low level beta counter to infer strontium-90 activity. Strontium-89 activity is determined by precipitating SrCO3 from the sample after yttrium separation.

This precipitate is counted on a nylon planchette and is covered with an 80 mg/cm2 aluminum absorber for low level beta counting.

Air Particulates Stable strontium carrier is added to the sample and it is leached in nitric acid to bring deposits into solution. The mixture is then filtered and the filtrate is reduced in volume by evaporation. Strontium is precipitated as Sr(NO3)2 using fuming (90%) nitric acid. A barium scavenge is used to remove some interfering species. An iron (ferric hydroxide) scavenge is performed, followed by addition of stable yttrium carrier and a 7 to 10 day period for yttrium ingrowth.

Yttrium is then precipitated as hydroxide, dissolved and re-precipitated as oxalate. The yttrium oxalate is mounted on a nylon planchette and is counted in a low level beta counter to infer strontium-90 activity.

Strontium-89 activity is determined by precipitating SrCO3 from the sample after yttrium separation. This precipitate is counted on a nylon planchette and is covered with 80 mg/cm2 aluminum absorber for low level beta counting.

Calculations of the result, two sigma errors and lower limits of detection (LLD) are expressed in activity of pCi/volume or pCi/mass:

RESULT Sr-89

=

(N/At-Bc-BA)/(2.22 V Ys DFsR-89ESR-89)

TWO SIGMA ERROR Sr-89

=

2(N/At+Bc+BA)/At)" 2/(2.22 V YsDFsR.89EsRa89)

LLD Sr-89

=

4.66(BC+BA)/At)"2/(2.22 V YsDFSR.8 9EsR-89)

RESULT Sr-90

=

(N/At-B)/(2.22 V Y1 Y2 DF IF E)

TWO SIGMA ERROR Sr-90

=

2(N/At+B)/At)'"/(2.22 V Y1 Y2 DF E IF)

C-7

LLD Sr-90

=

4.66(B/At)" 2/(2.22 V Y, Y2 IF DF E)

Where N

=

total counts from sample At

=

counting time for sample (min)

Bc

=

background rate of counter (cpm) using absorber configuration 2.22

=

dpm /pCi V

=

volume or weight of sample analyzed BA

=

background addition from Sr-90 and ingrowth of Y-90 Bc 0.016(K) + (K) Ey/,b)(IGy.go)

Ys

=

chemical yield of strontium ESR89

=

efficiency of the counter for Sr-89 with the 80 mg/cm. q.

aluminum absorber K

(NAt-Bc)y.9 o)/Ey.9 o IFy.go DFy.90Y,)

DFy-o

=

the decay factor for Y-90 from the "milk" time to the mid count time Ey.o

=

efficiency of the counter for Y-90 IFy.go

=

ingrowth factor for Y-90 from scavenge time to milking time IGy.go the ingrowth factor for Y-90 into the strontium mount from the "milk" time to the mid count time 0.016

=

the efficiency of measuring Sr-90 through a No. 6 absorber EY/,b.

=

the efficiency of counting Y-90 through a No. 6 absorber B

=

background rate of counter (cpm)

Y

=

chemical yield of yttrium Y2

=

chemical yield of strontium DF

=

decay factor of yttrium from the radiochemical milking time to the mid count time IF

=

ingrowth factor for Y-90 from scavenge time to the radiochemical milking time C-8

ANALYSIS OF SAMPLES FOR IODINE-131 Milk or Water Two liters of sample are first equilibrated with stable iodide carrier. A batch treatment with anion exchange resin is used to remove iodine from the sample. The iodine is then stripped from the resin with sodium hypochlorite solution, is reduced with hydroxylamine hydrochloride and is extracted into carbon tetrachloride as free iodine. It is then back-extracted as iodide into sodium bisulfite solution and is precipitated as palladium iodide. The sodium bisulfite solution and is precipitated as palladium iodide.

The precipitate is weighed for chemical yield and is mounted on a nylon planchette for low level beta counting. The chemical yield is corrected by measuring the stable iodide content of the milk or the water with a specific ion electrode.

Calculations of results, two sigma error and the lower limit of detection (LLD) in pCi/L:

RESULT

=

(N/At-B)/(2.22 E V Y DF)

TWO SIGMA ERROR

=

2((N/At+B)/At) /(2.22 E V Y DF) 112 LLD

=

4.66(B/At) /(2.22 E V Y DF) where:

N

=

total counts from sample (counts)

At

=

counting time for sample (min)

B

=

background rate of counter (cpm) 2.22

=

dpm/pCi V

=

volume or weight of sample analyzed Y

=

chemical yield of the mount or sample counted DF

=

decay factor from the collection to the counting date E

=

efficiency of the counter for 1-131, corrected for self absorption effects by the formula E

=

ES(exp-0.006 I M)/(exp-0.006 I MS)

Es

=

efficiency of the counter determined from an 1-131 standard mount Ms

=

mass of Pdl 2 on the standard mount, mg M

=

mass of PdI2 on the sample mount, mg C-9

GAMMA SPECTROMETRY OF SAMPLES Milk or Water A 1.0 liter Marinelli beaker is filled with a representative aliquot of the sample.

The sample is then counted for approximately 1000 minutes with a shielded high purity germanium (HPGe) detector coupled to a VAX-based data acquisition system which performs pulse height analysis.

Dried Solids other than Soils and Sediments A large quantity of the sample is dried at a low temperature, less than 1000C. As much as possible (up to the total sample) is loaded into a tared 1-liter Marinelli and weighed. The sample is then counted for approximately 1000 minutes with a shielded HPGe detector coupled to a VAX-based data acquisition system which performs pulse height analysis.

Fish As much as possible (up to the total sample) of the edible portion of the sample is loaded into a tared Marinelli and weighed. The sample is then counted for approximately 1000 minutes with a shielded HPGe detector coupled to a VAX-based data acquisition system which performs pulse height analysis.

Soils and Sediments Soils and sediments are dried at a low temperature, less than 1000C. The soil or sediment is loaded fully into a tared, standard 300 cc container and weighed. The sample is then counted for approximately six hours with a shielded HPGe detector coupled to a VAX-based data acquisition system which performs pulse height and analysis.

Charcoal Cartridges (Air Iodine)

Charcoal cartridges are counted up to five at a time, with one positioned on the face of a HPGe detector and up to four on the side of the HPGe detector. Each HPGe detector is calibrated for both positions. The detection limit for 1-131 of each charcoal cartridge can be determined (assuming no positive I-131) uniquely from the volume of air which passed through it. In the event I-131 is observed in the initial counting of a set, each charcoal cartridge is then counted separately, positioned on the face of the detector.

C-10

Air Particulates The thirteen airborne particulate filters for a quarterly composite for each field station are aligned one in front of another and then counted for at least six hours with a shielded HPGe detector coupled to a VAX-based data acquisition system which performs pulse height analysis.

A VAX software program defines peaks by certain changes in the slope of the spectrum. The program also compares the energy of each peak with a library of peaks for isotope identification and then performs the radioactivity calculation using the appropriate fractional gamma ray abundance, half life, detector efficiency, and net counts in the peak region.

The calculation of results, two sigma error and the lower limit of detection (LLD) in pCi/volume or pCi/mass:

RESULT

=

(S-B)/(2.22 t E V F DF)

TWO SIGMA ERROR

=

2(S+B) /(2.22 t E V F DF)

I 12 LLD

=

4.66(B) /(2.22 t E V F DF) where:

S

=

Area, in counts, of sample peak and background (region of spectrum of interest)

B

=

Background area, in counts, under sample peak, determined by a linear interpolation of the representative backgrounds on either side of the peak t

=

length of time in minutes the sample was counted 2.22 dpm/pCi E

detector efficiency for energy of interest and geometry of sample V

=

sample aliquot size (liters, cubic meters, kilograms, or grams)

F

=

fractional gamma abundance (specific for each emitted gamma)

DF

=

decay factor from the mid-collection date to the counting date C-l I

ADDENDUM TO GAMMA SPECTROMETRY PROCEDURE Ba-140 (half-life =-12.8d) decays to LA-140 (half-life -40 hrs) and the daughter radionuclide, La-140 approaches - 90 % of the Ba-140 activity within - 6 days. The La-140 photon energy at 1596 keV is used to quantify the Ba-140 activity due to its high photon emission probability yield (96%) producing a higher count rate when present and therefore, a smaller associated counting error.

Zr-95 (half-life = -65d) decays to Nb-95 (half-life = -35d). The photon energy of Nb-95 (-765 keV) is used to quantify Zr-95 because of the high photon emission probability yield (-100%) yielding a higher count rate and an associated lower counting error. The daughter radionuclide, Nb-95 approaches the Zr-95 activity after a time period of-65 days, an estimated time interval occurring between sample exposure, collection and shipping, and analysis.

C-12

ENVIRONMENTAL DOSIMETRY Environmental Dosimetry services to are provided by Proxtronics Dosimetry LLC, a Wholly Owned Subsidiary of Proxtronics, Inc. Proxtronics uses a thermoluminescent dosimeter (TLD) manufactured by Panasonic, Inc. Panasonic identifies it as an UD-814AI I TLD. The TLD has four elements, numbered 1-4.

Elements and their filtration are composed of:

ELEMENT MATERIAL FILTRATION I

nLi2nB40 7-Cu Thin plastic 2

CaSo4-Tm Plastic 3

CaSo4-Tm/Pb Lead 4

CaSo4-Tm/Pb Lead This material has a high light output, negligible thermally induced signal loss (fading) and negligible self-dosing. The energy response curve (as well as other features) satisfies NRC Regulatory Guide 4.13. Transit doses are accounted for by use of separate TLDs.

Prior to being sent to Cooper Nuclear Station, the Proxtronics badges are exposed to Cs-137, to a known dose and read in the Panasonic UD-710 reader, with reference badges to establish an element response level for each badge. Badges are then re-annealed for assignment and distribution to Cooper Nuclear Station.

Following the field exposure the badges are returned to Proxtronics for processing in a Panasonic UD-710 reader. Each element is heated and the measured light emission is recorded. The transit controls are read in the same manner.

Transit Controls are calculated using the following equation:

R D(E3[

+ E41 + E32 + E4) ]

,+Ee4 TRANSDOSE = L4 J

2 C-13

LOWER LIMIT of DETECTION FORMULAS The LLD formulas in Section C are consistent with the LLD discussion in the ODAM. The term Sb in the ODAM equals 41B/t by Poisson statistics, where B = blank counts and t = blank counting intervals. The decay factor term e-16' in the ODAM is the same as the DF terms in Section C, but does not appear in certain analyses such as gross beta because decay does not apply. In the tritium analysis, decay is not considered because of the relatively long half-life.

Efficiencies and volumes are consistent between the two documents, Chemical yields appear in Section C where applicable but do not apply to other analyses such as tritium and gross beta.

C-14

APPENDIX D DETECTION LIMITS AND REPORTING LEVELS D-1

NEBRASKA PUBLIC POWER - COOPER NUCLEAR STATION DETECTION LIMITS AND REPORTING LEVELS Isotope ODAM LLD NRC Rept. Level Water - pCi/liter Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-95 Nb-95 1-131 Cs-1 34 Cs-1 37 Ba-140 La-140 4

2000 15 30 15 15 30 30 15 1 (C) 15 18 60 15 N/A 20000'r) /30000(b 1000 400 1000 300 300 400 400 2

30 50 200 200 Air Filter - PCi/M3 Gross Beta 1-131 Cs-1 34 Cs-1 37 0.01 0.07 0.05 0.06 N/A 0.9 10 20 Fish - pCi/kg-wet Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-1 34 Cs-1 37 130 260 130 130 260 130 150 30000 10000 30000 10000 20000 1000 2000 Milk - pCi/liter 1-131 Cs-134 Cs-137 Ba-140 La-140 I

15 18 60 15 3

60 70 300 300 (a) For drinking water samples (b) For samples of water not used as a source of drinking water (c) LLD for drinking water D-2

NEBRASKA PUBLIC POWER - COOPER NUCLEAR STATION DETECTION LIMITS AND REPORTING LEVELS Isotope ODAM LLD NRC Rept. Level Vegetation - pCi/kq-wet 1-131 Cs-1 34 Cs-1 37 Sediment - pCi/kg-dry Cs-1 34 Cs-1 37 60 60 80 100 1000 2000 150 180 N/A N/A D-3

APPENDIX E REMP SAMPLING AND ANALYTICAL EXCEPTIONS E-1

EXCEPTIONS Appendix E contains the exceptions to the 2003 REMP Program. Where possible, causes of the deviation have been corrected to prevent recurrence. One air particulate sample was unavailable due to a ground fault interrupter failure.

All deviations from the sampling schedule have been documented on the data tables. Data Tables are in Section VII E-2

Exceptions for Scheduled REMP Sampling and Analysis During 2003, NPPD Cooper Nuclear Station Station(s)

Pathway Sample Collection Period ExceptionlReason Actions Taken and Replacement Samples, Where Applicable 8

Airborne Air Particulate 11/04/03 - 11/12/03 Ground Fault Interupter Checked air pump for abnormalities.

& Charcoal Failed Ground fault was reengaged and Filter pump placed back in service.

mrn

APPENDIX F

SUMMARY

OF DOSES TO A MEMBER OF THE PUBLIC OFF-SITE F-1

LIQUID EFFLUENT DOSE CALCULATIONS Doses to the maximum individual and 0 to 50 - mile population resulting from the release of radioactive material in liquid effluents from Cooper Nuclear Station were calculated using the LADTAP II computer program. The LADTAP II program implements the radiological dose models of Regulatory Guide 1.109 for determining the radiation exposure to man from three principal exposure pathways in the aquatic environment -- potable water, aquatic foods, and recreational water use. Doses to both the maximum individual and 0 to 50 mile population are calculated as a function of age group and pathway for significant body organs, and are presented in Tables 1 - 6.

Assumptions and data sources used for input to the LADTAP II code are described in a separate section of this appendix (see page C5 1).

F-2

TABLE 1.

Doses to Maximum Individual at the Site Boundary, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, January-June 2003, Cooper Nuclear Station Dose to Individual, mrem Period and Pathway Skin Bone Liver 1st Quarter Drinking 0.00 E+00 0.00 E+00 Water Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 Totals 0.00 E+00 0.00 E+00 0.00 E+00 2nd Quarter It Eating Fish w

0.00 E+00 2.07 E-06 Drinking Water 0.00 E+00 9.31 E-03 Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 Totals 0.00 E+00 0.00 E+00 9.31 E-03 Totals for 1st & 2nd Quarters 0.00 E+00 0.00 E+00 9.31 E-03 Calculated doses are based on the following periods Drinking water and shoreline:

January -

December Total Body 0.00 E+00 0.00 E+00 0.00 E+00 2.07 E-06 9.31 E-03 0.00 E+00 9.31 E-03 9.31 E-03 f exposures: F Thyroid 0.00 E+00 0.00 E+00 0.00 E+00 2.07 E-06 9.31 E-03 0.00 E+00 9.31 E-03 9.31 E-03

'ishing: April Kidney 0.00 E+00 0.00 E+00 0.00 E+00 2.07 E-06 9.31 E-03 0.00 E+00 9.31 E-03 Lung 0.00 E+00 0.00 E+00 0.00 E+00 2.07 E-06 9.31 E-03 0.00 E+00 9.31 E-03 GI-LLI 0.00 E+00 0.00 E+00 0.00 E+00 2.07 E-06 9.31 E-03 0.00 E+00 9.31 E-03 9.31 E-03 9.31 E-03 9.31 E-03 t

November;

TABLE 2.

Doses to Maximum Individual at the Site Boundary, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, July-December 2003, Cooper Nuclear Station Dose to Individual, mrem Period and Pathway 3rd Quarter Eating Fish Drinking Water Shoreline Totals 4th

-6 Quarter Eating Fish Drinking Water Shoreline Totals Skin 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Bone Liver Total Body Thyroid Kidney Lung GI-LLI 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 3.90 7.85 0.00 7.85 0.00 0.00 0.00 0.00 E-06 E-03 E+00 E-03 E+00 E+00 E+00 E+00 3.90 7.85 0.00 7.85 0.00 0.00 0.00 0.00 E-06 E-03 E+00 E-03 E+00 E+00 E+00 E+00 3.90 7.85 0.00 7.85 0.00 0.00 0.00 0.00 E-06 E-03 E+00 E-03 E+00 E+00 E+00 E+00 3.90 7.85 0.00 7.85 0.00 0.00 0.00 0.00 E-06 E-03 E+00 E-03 E+00 E+00 E+00 E+00 3.90 7.85 0.00 7.85 0.00 0.00 0.00 0.00 E-06 E-03 E+00 E-03 E+00 E+00 E+00 E+00 3.90 7.85 0.00 7.85 0.00 0.00 0.00 0.00 E-06 E-03 E+00 E-03 E+00 E+00 E+00 E+00 Totals for 3rd & 4th Quarters 0.00 E+00 0.00 E+00 7.85 E-03 7.85 E-03 7.85 E-03 7.85 E-03 7.85 E-03 7.85 E-03 i

Fishing: April - November; on the following periods of exposures:

Drinking water and shoreline: January - December

TABLE 3.

Summiary of Doses to Maximum Individual at the Site Boundary, Resulting from Exposure to Radioactivity Discharged in Liquid Effluents, January-December 2003, Cooper Nuclear Station Dose to Individual, mrem Period and Pathway Skin Bone Liver Total Body Thyroid Kidney Lung GI-LLI 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 9.31 E-03 7.85 E-03 0.00 E+00 9.31 E-03 7.85 E-03 0.00 E+00 9.31 E-03 7.85 E-03 0.00 E+00 9.31 E-03 7.85 E-030 0.00 E+00 9.31 E-03 7.85 E-03 0.00 E+00 9.31 E-03 7.85 E-03 0.00 E+00 nI Totals for 2003 0.00 E+00 0.00 E+00 1.72 E-02 1.72 E-02 1.72 E-02 1.72 E-02 1.72 E-02 1.72 E-02 I

TABLE 4.

Doses to Population Within a 50-Mile Radius, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, January-June 2003, Cooper Nuclear Station Dose to Population, manrem Period and Pathway Skin Total Body Bone Liver Thyroid Kidney Lung GI-LLI 1st Quarter Drinking Water 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Shoreline Totals 2nd Quarter enI Eating Fish Co Drinking Water Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 6.86 5.04 0.00 E+00 E+00 E-06 E-03 E+00 0.00 0.00 6.86 5.04 0.00 E+00 E+00 E-06 E-03 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 6.86 5.04 0.00 E+00 E+00 E-06 E-03 E+00 0.00 E+00 0.00 E+00 6.86 E-06 5.04 E-03 0.00 E+00

6. 86 5.04 0.00 E-06 E-03 E+00 6.86 5.04 0.00 E-06 E-03 E+00 Swimming Boating Totals Totals for 1st & 2nd Quarters 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 5.05 E+00 E+00 E-03 0.00 0.00 5.05 E+00 E+00 E-03 0.00 0.00 S.05 E+00 E+00 E-03 0.00 0.00 S.05 E+00 E+00 E-03 0.00 0.00 5.05 E+00 E+00 E-03 0.00 E+00 0.00 E+00 5.05 E-03 0.00 E+00 0.00 E+00 5.05 E-03 5.05 E-03 5.05 E-03 5.05 E-03 5.05 E-03 5.05 E-03 Calculated doses are based on the following periods of exposures: Fishing and Boating: April -

November; Drinking water and shoreline:

January -

December; Swimming: June -

September Exposure from drinking water is calculated for the city of St. Joseph, Missouri, nearest public water intake from the Missouri River, 84 miles downstream

TABLE 5.

Doses to Population Within a 50-Mile Radius, Resulting From Exposure Effluents, July-December 2003, Cooper Nuclear Station to Radioactivity Discharged in Liquid Dose to Population, manrem Period and Pathway Skin Bone Liver Total Body Thyroid Kidney Lung GI-LLI 3rd Quarter Eating Fish Drinking Water Shoreline Swimming Boating Totals 4th Quarter Eating Fish Drinking Water Shoreline 0.00 E+00 1.29 E-05 1.29 E-05 1.29 E-05 1.29 E-05 1.29 E-05 1.29 E-05 0.00 E+00 9.50 E-03 9.50 E-03 9.50 E-03 9.50 E-03 9.50 E-03 9.50 E-03 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 171 0.00 E+00 0.00 E+00 9.51 E-03 9.51 E-03 9.51 E-03 9.51 E-03 9.51 E-03 9.51 E-03 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals Totals for 3rd & 4th 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Quarters 0.00 E+00 0.00 E+00 9.51 E-03 9.51 E-03 9.51 E-03 9.51 E-03 9.51 E-03 9.51 E-03 Calculated doses are based on the following periods of exposures: Fishing and Boating: April -

November; Drinking water and shoreline:

January -

December; Swimming: June -

September Exposure from drinking water is calculated for the city of St. Joseph, Missouri, nearest public water intake from the Missouri River, 84 miles downstream

TABLE

6.

Summary of Doses to Population Within a 50-Mile Radius, Resulting from Exposure to Radioactivity Discharged in Liquid Effluents, January-December 2003, Cooper Nuclear Station Dose to Population, manrem Period and Pathway Skin Bone Liver Total Body Thyroid Kidney Lung GI-LLI 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Totals for 2003 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 5.05 E-03 9.51 E-03 0.00 E+00 5.05 E-03 9.51 E-03 0.00 E+00 5.05 E-03 9.51 E-03 0.00 E+00 5.05 E-03 9.51 E-03 0.00 E+00 5.05 E-03 9.51 E-03 0.00 E+00 5.05 E-03 9.51 E-03 0.00 E+00 0.00 E+00 0.00 E+00 1.46 E-02 1.46 E-02 1.46 E-02 1.46 E-02 1.46 E-02 1.46 E-02

GASEOUS EFFLUENT DOSE CALCULATIONS Doses to the maximum individual and 0 to 50 mile population resulting from the release of radioactive material in gaseous effluents from the Cooper Nuclear Station were calculated using the GASPAR computer code. Four sites were selected for individual dose calculations: the site boundary, the nearest residence, the nearest garden and the nearest cow. GASPAR implements the radiological dose models of Regulatory Guide 1.109 for determining the radiation exposure to man from four principal atmospheric exposure pathways: plume, ground, inhalation, and ingestion. Doses to the maximum individual and the population are calculated as a function of age group and pathway for significant body organs.

Tables 1 through 7 present maximum individual doses. Population doses are given in Tables 8 through 14.

Because of differences in the amount of valid meteorological data recovered, dose contributions from the quarterly periods of 2003 cannot be summed to provide semiannual doses.

Assumptions and data used for input to the GASPAR code are described in a separate section of this appendix (see page C5 1).

F-8

TABLE 1.

DOSES TO NAXIM4M INDIVIDUAL (MREM),

JANUARY-MARCH 2003 SPECIAL LOCATION NO.

1 A

Site Boundary AT

.69 MILES NNW ANNUAL BETA AIR DOSE = 5.78E-03 MILLRADS ANNUAL GAM1MA AIR DOSE = 8.87E-03 MILLRADS PATHWAX T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_---+-______-+____-__+

PLUME 5.90E-03 : 5.90E-03 : 5.90E-03 : 5.90E-03 : 5.90E-03 : 5.90E-03 : 5.96E-03 : 1.12E-02

-________+___

__+

_+_

+__

__+

_+_--+

-____+____-

+__-

_ +

GROUND 1.34E-03 : 1.34E-03 : 1.34E-03 : 1.34E-03

1.34E-03 : 1.34E-03 : 1.34E-03 : 1.58E-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 2.52E-05 1.90E-04 2.52E-05 2.08E-05 1.29E-05 2.16E-03 1.68E-09 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+

TEEN

3.90E-05 : 2.03E-04 : 4.13E-05 : 3.16E-05
1.96E-05 : 2.92E-03 : 2.84E-09 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-+-+-+___-__+

CHILD

7.77E-05 : 1.33E-04 : 1.OOE-04 : 4.97E-05
3.10E-05 : 5.59E-03 : 4.07E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 5.48E-06 4.60E-05 3.28E-07 2.69E-06 3.29E-07 5.83E-05 5.86E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

TEEN

4.34E-06 : 2.47E-05 : 2.75E-07 : 2.09E-06 : 2.68E-07 : 4.22E-05 : 5.07E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

6.73E-06 : 1.25E-05 : 5.16E-07 : 2.50E-06 : 3.37E-07 : 6.37E-05 : 5.64E-11 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT : 4.05E-06 1.18E-05 4.44E-06 5.60E-06 8.59E-06 1.62E-03 2.26E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

TEEN

6.83E-06 : 1.41E-05 : 8.08E-06 : 9.90E-06
1.53E-05 : 2.56E-03 : 4.26E-10 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

1.30E-05 : 9.56E-06 : 1.97E-05 : 1.70E-05 : 2.55E-05 : 5.07E-03
6.17E-10 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-___-+___-__+

INFANT : 2.36E-05

8.56E-06 : 4.03E-05 : 4.10E-05
4.43E-05
1.23E-02 : 1.23E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT : 3.61E-06 3.20E-06 6.18E-06 6.07E-06 1.03E-05 1.94E-03 2.71E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-______+__-+__-__+

TEEN

6.03E-06 : 4.10E-06 : 1.13E-05 : 1.08E-05 : 1.83E-05 : 3.08E-03 : 5.11E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

CHILD

1.12E-05 : 3.07E-06 : 2.75E-05 : 1.88E-05 : 3.05E-05 : 6.09E-03 : 7.40E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

INFANT : 2.11E-05 : 2.93E-06 : 5.58E-05 : 4.58E-05 : 5.30E-05 : 1.48E-02 : 1.47E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 8.88E-07 9.36E-06 8.17E-07 1.69E-06 2.15E-06 2.52E-04 1.30E-04 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

TEEN

1.18E-06 : 1.81E-05 : 1.15E-06 : 2.29E-06 : 2.93E-06 : 3.16E-04 : 1.91E-04 : 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

CHILD

1.32E-06 : 7.34E-05 : 1.56E-06 : 2.15E-06 : 2.71E-06 : 3.64E-04 : 1.55E-04 : 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-+-_____-+___-__+

INFANT : 8.39E-07 : 6.02E-05 : 1.21E-06 : 1.81E-06 : 1.76E-06 : 3.33E-04 : 1.02E-04 : 0.OOE+00

+--

-+--- -+-------------

+--+--++----

+

+-+-+

DTI

'0D

TABLE 1.

DOSES TO MAXIMUM INDIVIDUAL (MpDM),

JA'NUARY-MARCH 2003 (CoNTINUED)

SPECIAL LOCATION NO.

2 A

Site Boundary AT

.67 MILES N

ANNUAL BETA AIR DOSE = 8.26E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.27E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

PLUM

8.43E-03 : 8.43E-03 : 8.43E-03 : 8.43E-03 : 8.43E-03 : 8.43E-03
8.52E-03 : 1.60E-02 :

-________+__________+__________+__________+__________+__________+__________+_---+-+-_____-+___-__+

GROUND

2.65E-03 : 2.65E-03 : 2.65E-03 : 2.65E-03 : 2.65E-03 : 2.65E-03 : 2.65E-03 : 3.12E-03 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 5.O1E-05 3.78E-04 6.05E-05 4.12E-05 2.58E-05 4.33E-03 3.43E-09 0.OOE+00 TEEN

7.76E-05 : 4.02E-04 : 9.93E-05 : 6.27E-05 : 3.91E-05 : 5.84E-03 : 5.82E-09 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

CHILD

1.55E-04 : 2.63E-04 : 2.41E-04 : 9.86E-05 : 6.21E-05 : 1.12E-02 : 8.35E-09 0.OOE+00 :

MEAT ADULT 1.08E-05 9.06E-05 7.58E-07 5.30E-06 6.59E-07 1.17E-04 1.20E-10 0.00E+00

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-___-+___-__+

TEEN

8.56E-06 : 4.88E-05 : 6.36E-07 : 4.13E-06 : 5.36E-07 : 8.45E-05 : 1.04E-10 0.00E+00 :

-________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

CHILD

1.33E-05 : 2.46E-05 : 1.20E-06 : 4.94E-06 : 6.73E-07 : 1.28E-04 : 1.16E-10 0.OOE+00

_________+_________+_____--+--+-+_-_____+__________+__________+__________+______--____+-_________+

COW MILK :

ADULT

8.08E-06 2.33E-05 9.36E-06 1.12E-05 1.72E-05 3.24E-03 4.50E-10 0.OOE+00

+

-+--------------------------+-

++

+-----

TEEN

1.36E-05 : 2.79E-05 : 1.70E-05 : 1.98E-05 : 3.07E-05 : 5.13E-03 : 8.48E-10 0.OOE+00 CHILD
2.60E-05 : 1.90E-05 : 4.16E-05 : 3.41E-05 : 5.10E-05
1.02E-02 : 1.23E-09 0.OOE+00 :

-________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-_____

+

INFANT : 4.71E-05 : 1.70E-05 : 8.48E-05 8.20E-05 : 8.86E-05 : 2.47E-02 : 2.46E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

7.24E-06 6.53E-06 1.33E-05 1.21E-05 2.06E-05 3.89E-03 5.40E-11 O.OOE+00

-________+__________+______--+ -

__+

-_________+__________+__________+__________----

+

-__+-_______+

TEEN

1.21E-05 : 8.38E-06 : 2.44E-05 : 2.16E-05 : 3.67E-05 : 6.16E-03 : 1.02E-10 0.OOE+00 :

-________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

CHILD

2.26E-05 : 6.29E-06 : 5.95E-05 : 3.75E-05 : 6.10E-05 : 1.22E-02 : 1.48E-10 : O.OOE+00 :

-________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

INFANT : 4.26E-05 : 6.01E-06 : 1.20E-04 : 9.16E-05 : 1.06E-04 : 2.96E-02 : 2.95E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL.:

ADULT 1.31E-06 1.40E-05 1.20E-06 2.49E-06 3.14E-06 : 3.69E-04 1.95E-04 0.OOE+00

-________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

TEEN

1.74E-06 : 2.72E-05 : 1.69E-06 : 3.37E-06 : 4.29E-06 : 4.62E-04 : 2.86E-04 : O.OOE+00 :

-________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

CHILD

1.95E-06 : 1.10E-04 : 2.29E-06 : 3.16E-06 : 3.97E-06 : 5.32E-04 : 2.33E-04 : 0.OOE+00 :

-________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

INFANT : 1.24E-06 : 9.05E-05 : 1.78E-06 : 2.66E-06 : 2.58E-06 : 4.87E-04 : 1.53E-04 : 0.OOE+00

+-

+ -----

+------

0

TABLE 1.

DOSES TO MAXIMUM INDIVIDUAL (MEM4),

JANUARY-MARCH 2003 (CONTINUED)

SPECIAL LOCATION NO.

3 A

Nearest Resident AT

.90 MILES NW ANNUAL BETA AIR DOSE = 1.30E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.96E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

_______-_+-_________+_____-____+_________-+_________-+__________+__________+__________+_________-+

PLUME

1.30E-03 : 1.30E-03 : 1.30E-03 : 1.30E-03 : 1.30E-03 : 1.30E-03 : 1.31E-03 : 2.50E-03 :

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __-_

_ +

GROUND

3.73E-04 3.73E-04 : 3.73E-04 : 3.73E-04 : 3.73E-04 : 3.73E-04 : 3.73E-04 : 4.39E-04 :

VEGET ADULT 7.27E-06 5.42E-05 1.42E-05 5.90E-06 3.81E-06 6.44E-04 5.46E-10 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+

+

+__-

_ +

TEEN

1.13E-05 : 5.79E-05 : 2.35E-05 : 8.98E-06 : 5.78E-06 : 8.69E-04 : 9.34E-10 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __-_

_ +

CHILD

2.26E-05 : 3.81E-05 : 5.72E-05 : 1.41E-05 : 9.18E-06 : 1.66E-03 : 1.35E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.52E-06 1.28E-05 1.66E-07 7.49E-07 9.76E-08 1.74E-05 1.93E-11 O.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __-_

_ +

TEEN

1.21E-06 : 6.86E-06 : 1.40E-07 : 5.83E-07 : 7.94E-08 : 1.26E-05 : 1.70E-11 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_---________+-

+ ___-_

_ +

CHILD

1.87E-06 : 3.47E-06 : 2.63E-07 : 6.97E-07 : 9.98E-08 : 1.90E-05 : 1.90E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT : 1.19E-06 3.35E-06 1.64E-06 1.66E-06 2.56E-06 4.83E-04 6.55E-11 O.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __-_

_ +

TEEN

2.01E-06 : 4.02E-06 : 2.98E-06 : 2.93E-06 : 4.56E-06 : 7.64E-04 : 1.24E-10 : O.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+

+ ___-_

_ +

CHILD

3.83E-06 : 2.75E-06 : 7.29E-06 : 5.04E-06 : 7.58E-06 : 1.51E-03 : 1.80E-10 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_---________+-

+ ___-_

_ +

INFANT : 6.96E-06 : 2.47E-06 : 1.47E-05 : 1.21E-05 : 1.32E-05 : 3.67E-03 : 3.62E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

1.09E-06 1.03E-06 2.49E-06 1.81E-06 3.06E-06 5.79E-04 7.87E-12 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __-_

_ +

TEEN

1.82E-06 : 1.33E-06 : 4.56E-06 : 3.20E-06 : 5.46E-06 : 9.16E-04 : 1.49E-11 : 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+

+ ___-_

_ +

CHILD

3.42E-06 : 1.01E-06 : 1.12E-05 : 5.58E-06 : 9.08E-06 : 1.81E-03 : 2.16E-11 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_---________+-

+ ___-_

_ +

INFANT : 6.44E-06 : 9.72E-07 : 2.22E-05 : 1.36E-05 : 1.58E-05 : 4.40E-03 : 4.35E-11 : 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 2.06E-07 2.21E-06 2.03E-07 3.91E-07 4.89E-07 5.64E-05 2.94E-05 0.OOE+00

_________+-_________+________-_+_________-+________-_+________-_+________-_+________-_+________-_+

TEEN

2.74E-07 : 4.34E-06 : 2.85E-07 : 5.29E-07 : 6.67E-07 : 7.06E-05 : 4.32E-05 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+___- _

_ +

CHILD

3.08E-07 : 1.80E-05 : 3.87E-07 : 4.98E-07 : 6.18E-07 : 8.14E-05 : 3.52E-05 0.OOE+00 :

_________+ ______

___+__

+_____

____+

__+___

___+_--+

-______+_+_+-_

_+

INFANT : 1.97E-07 : 1.49E-05 : 2.98E-07 : 4.20E-07 : 4.01E-07 : 7.44E-05 : 2.32E-05 0.OOE+00

+

+ -- - -

+ -- -

44-orl I

TABLE 1.

DOSES TO MAXI4UM INDIVIDUAL MREM), JANUARY-MARCH 2003 (CONTINUED)

SPECIAL LOCATION NO.

4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 2.80E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 3.84E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

_______-_+-_________+_____-____+_________-+_________-+________-_+________-_+________-_+________-_+

PLUME

2.56E-04 : 2.56E-04 : 2.56E-04 : 2.56E-04
2.56E-04 : 2.56E-04 : 2.59E-04
5.21E-04 :

_______-_+-_________+_____-____+_________-+_________-+________-_+________-_+_________-+________-_+

GROUND

2.65E-05 : 2.65E-05 : 2.65E-05 : 2.65E-05 : 2.65E-05 : 2.65E-05 : 2.65E-05 : 3.12E-05 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 5.53E-07 4.03E-06 1.91E-06 4.37E-07 3.OOE-07 5.14E-05 4.88E-11 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+

+ ___-_

_ +

TEEN

8.58E-07 : 4.33E-06 : 3.16E-06 : 6.64E-07 : 4.56E-07 : 6.92E-05 : 8.45E-11 : O.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __-_

_ +

CHILD

1.73E-06 : 2.88E-06 : 7.70E-06 : 1.05E-06 : 7.24E-07 : 1.33E-04 : 1.23E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.09E-07 9.10E-07 2.11E-08 5.37E-08 7.72E-09 1.38E-06 1.75E-12 O.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+__-

_ +

TEEN

8.62E-08 : 4.90E-07 : 1.78E-08 : 4.18E-08 : 6.28E-09 : 1.OOE-06 : 1.56E-12 : O.OOE+00 :

_____-__+__________+__________+__________+__________+__________+__________+__--________+-________+

CHILD : 1.34E-07 : 2.48E-07 : 3.35E-08 : 5.01E-08 : 7.91E-09 : 1.51E-06 : 1.77E-12 : O.OOE+00 :

COW MILK:

ADULT : 9.31E-08 2.49E-07 1.66E-07 1.30E-07 2.04E-07 3.85E-05 5.02E-12 O.00E+OO

_ _________+ __________+__________+__________+__________+__________+__________+-

________+ ___- __

_ +

TEEN

1.57E-07 : 3.01E-07 : 3.04E-07 : 2.31E-07 : 3.63E-07 : 6.09E-05 : 9.54E-12 : O.OOE+OO :

_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+

CHILD

3.OOE-07 : 2.07E-07 : 7.46E-07 : 3.98E-07 : 6.04E-07 : 1.20E-04 : 1.39E-11 : O.00E+OO :

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+

+

+

+___- _

_ +

INFANT : 5.47E-07 : 1.88E-07 : 1.49E-06 : 9.61E-07 : 1.05E-06 : 2.93E-04 : 2.85E-11 : O.00E+OO :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT : 8.87E-08 9.16E-08 2.73E-07 1.44E-07 2.44E-07 4.62E-05 6.02E-13 O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

-__+____-

+__-

_ +

TEEN

1.49E-07 : 1.20E-07 : 5.01E-07 : 2.55E-07 : 4.35E-07 : 7.30E-05 : 1.14E-12 : O.OOE+00 :

_________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+________-_+

CHILD

2.81E-07 : 9.16E-08 : 1.23E-06 : 4.44E-07 : 7.23E-07 : 1.44E-04 : 1.67E-12 : O.00E+00 :

_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+

INFANT : 5.30E-07 : 8.90E-08 : 2.42E-06 : 1.08E-06 : 1.26E-06 : 3.51E-04 : 3.42E-12 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL :

ADULT : 4.16E-08 4.35E-07 5.70E-08 7.90E-08 9.45E-08 : 9.88E-06 : 4.36E-06 O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

-__+

_+

TEEN

5.57E-08 : 9.19E-07 : 8.04E-08 : 1.07E-07 : 1.29E-07 : 1.24E-05 : 6.46E-06 : O.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_---________+- + ___- _

_ +

CHILD

6.38E-08 : 4.27E-06 : 1.10E-07 : 1.02E-07 : 1.20E-07 : 1.42E-05 : 5.29E-06 : O.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+__-

_ +

INFANT : 4.24E-08 : 3.60E-06 : 8.22E-08 : 8.90E-08 : 7.83E-08 : 1.30E-05 : 3.59E-06 : O.OOE+00 :

4---------

-- 4 ------------

++

TABLE 1.

DOSES TO MAXIMUM INDIVIDUAL (ME14),

JANUARY-MARCH 2003 (CONTINUED)

SPECIAL LOCATION NO.

5 A

Nearest Garden AT 1.90 MILES NNW ANNUAL BETA AIR DOSE - 6.67E-04 MILIADS ANNUAL GAM4M AIR DOSE -

1.02E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______--+_________-+_________-+__________+__________+__________+______--____+-_________+

PLUME 6.81E-04 : 6.81E-04 : 6.81E-04 : 6.81E-04 : 6.81E-04

6.81E-04 : 6.88E-04 : 1.29E-03 :

GROUND 1.11E-04 : 1.11E-04

1.11E-04 : 1.11E-04 : 1.11E-04 : 1.11E-04 : 1.11E-04 : 1.31E-04 :

VEGET ADULT 2.23E-06 1.65E-05 5.58E-06 1.79E-06 1.18E-06 2.01E-04 1.78E-10 0.00E+00

-________+__________+__________+__________+____--+-+-+-+_-______+__________+______--+-__+-_______+

TEEN

3.45E-06 : 1.76E-05 : 9.22E-06 : 2.72E-06 : 1.79E-06 : 2.71E-04 : 3.06E-10 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

CHILD

6.94E-06 : 1.16E-05
2.25E-05 : 4.29E-06 : 2.85E-06 : 5.19E-04 : 4.43E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 4.56E-07 3.82E-06 6.34E-08 2.24E-07 3.03E-08 5.41E-06 6.32E-12 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

TEEN 3.61E-07 : 2.05E-06 5.33E-08 : 1.75E-07 : 2.47E-08 : 3.92E-06 : 5.60E-12 : O.OOE+00 :

+__________+-_________+____-_____+______-___+_________-+____-_+__-_+__-_+

CHILD 5.61E-07 : 1.04E-06 1.OOE-07 : 2.09E-07 : 3.10E-08 : 5.91E-06 : 6.30E-12 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT

3.68E-07 1.02E-06 5.63E-07 5.14E-07 7.97E-07 1.50E-04 2.01E-11 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

TEEN

6.21E-07 : 1.22E-06 : 1.03E-06 : 9.08E-07 : 1.42E-06 : 2.38E-04 : 3.81E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

CHILD

1.19E-06 : 8.39E-07 : 2.52E-06 : 1.57E-06 : 2.36E-06 : 4.71E-04 : 5.55E-11 0.00E+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

INFANT : 2.16E-06 : 7.56E-07 : 5.05E-06 : 3.77E-06 : 4.11E-06 : 1.14E-03 : 1.12E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOAIFILK :

ADULT

3.42E-07 3.36E-07 8.87E-07 5.62E-07 9.54E-07 1.80E-04 2.41E-12 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-__+____-+__-__+

TEEN 5.73E-07 : 4.35E-07 : 1.62E-06 : 9.98E-07 : 1.70E-06 : 2.86E-04 : 4.57E-12 0.OOE+00 :

-________+___

__+

__+

_+ ___

_+_

_+_

+_--+-

+

+

+__-

_ +

CHILD 1.08E-06 : 3.31E-07 : 3.99E-06 : 1.74E-06 : 2.83E-06 : 5.65E-04 : 6.65E-12 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

INFANT : 2.03E-06 : 3.20E-07 : 7.90E-06 : 4.24E-06 : 4.92E-06 : 1.37E-03 : 1.35E-11 : 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHA ADULT

1.05E-07 : 1.15E-06 : 1.16E-07 2.OOE-07 : 2.54E-07 2.97E-05 : 1.43E-05 : 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

TEEN

1.39E-07 : 2.26E-06 : 1.64E-07 : 2.70E-07 : 3.47E-07 : 3.72E-05 : 2.10E-05 : 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

CHILD

1.56E-07 : 9.38E-06 : 2.23E-07 : 2.55E-07 : 3.21E-07 : 4.28E-05 : 1.71E-05 : 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

INFANT : 1.01E-07 : 7.75E-06 : 1.70E-07 : 2.16E-07 : 2.09E-07 : 3.92E-05 : 1.14E-05 : 0.OOE+00 :

+-----

+

+

-+-

+

+

+-+

I w~

TABLE 2.

DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2003)

SPECIAL LOCATION NO.

1 A

Site Boundary AT

.69 MILES NNW ANNUAL BETA AIR DOSE = 6.37E-02 MILLRADS ANNUAL GA4'A AIR DOSE = 9.61E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-__+_+_+-___+

PLUME

6.39E-02 : 6.39E-02 : 6.39E-02 : 6.39E-02 : 6.39E-02 : 6.39E-02
6.46E-02 : 1.23E-01

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-____+_+-___+

GROUND 2.03E-03

2.03E-03 : 2.03E-03 : 2.03E-03 : 2.03E-03
2.03E-03 : 2.03E-03
2.38E-03 VEGET ADULT 5.01E-05 3.42E-04 3.59E-04 3.58E-05 2.90E-05 5.11E-03 6.59E-09 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-__+___+-___+

TEEN

7.81E-05 : 3.73E-04 : 5.95E-04 : 5.43E-05 : 4.38E-05 : 6.87E-03 : 1.14E-08 : O.00E+0O

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

1.61E-04 : 2.54E-04 : 1.45E-03 : 8.65E-05 : 6.97E-05 : 1.32E-02 : 1.66E-08 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 8.41E-06 6.98E-05 3.77E-06 4.17E-06 7.45E-07 1.37E-04 2.36E-10 O.00E+0O

-________+__________+__________+__________+__________+__________+__________+_---________+-+___-__+

TEEN

6.66E-06 : 3.76E-05 : 3.18E-06 : 3.25E-06 : 6.07E-07 : 9.89E-05 : 2.11E-10 : O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-__+___+-___+

CHILD

1.04E-05 : 1.90E-05 : 6.OOE-06 : 3.90E-06 : 7.67E-07 : 1.49E-04 : 2.40E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+-

COW MILK ADULT

9.03E-06 2.18E-05 2.47E-05 1.30E-05 2.09E-05 3.86E-03 6.66E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-____+_+_+-___+

TEEN

1.53E-05 : 2.68E-05 : 4.52E-05 : 2.31E-05 : 3.73E-05 : 6.12E-03 : 1.27E-09 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

2.94E-05 : 1.90E-05 : 1.11E-04 : 4.OOE-05 : 6.19E-05 : 1.21E-02 : 1.85E-09 : O.OOE+00 INFANT : 5.40E-05 : 1.75E-05 : 2.18E-04 : 9.69E-05 : 1.08E-04 : 2.95E-02 : 3.79E-09 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

9.33E-06 1.17E-05 4.40E-05 1.47E-05 2.50E-05 4.64E-03 7.99E-11 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

TEEN

1.57E-05 : 1.56E-05 : 8.07E-05 : 2.61E-05 : 4.47E-05 : 7.35E-03 : 1.52E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

3.04E-05 : 1.23E-05 : 1.99E-04 : 4.55E-05 : 7.43E-05 : 1.46E-02 : 2.22E-10 : O.OOE+00 INFANT : 5.74E-05 : 1.21E-05 : 3.87E-04 : 1.11E-04 : 1.29E-04 : 3.54E-02 : 4.55E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+-

INHAL ADULT 8.66E-07 6.30E-06 1.02E-06 1.58E-06 1.77E-06 2.02E-04 1.09E-04 O.OOE+00

-________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

TEEN

1.16E-06 : 8.33E-06 : 1.44E-06 : 2.15E-06 : 2.44E-06 : 2.55E-04 : 1.60E-04 : O.OOE+00

-________+__________+__________+_____--+-__-+-_________+__________+__________+___---___+-________+

CHILD

1.33E-06 : 2.74E-05 : 1.96E-06 : 2.05E-06 : 2.28E-06 : 2.98E-04 : 1.30E-04 : O.OOE+00

-________+__________+__________+_____--+-__-+-_________+__________+__________+___--+--___+-______+

INFANT : 8.75E-07 : 2.34E-05 : 1.48E-06 : 1.78E-06 : 1.49E-06 : 2.73E-04 : 8.44E-05 : O.OOE+00

+---------------+-

+---- -----------

+ -+---------++

+

+

+

'll

TABLE 2.

DOSES TO MAXIMUM INDIVIDUAL (MEM4),

APRIL-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

2 A

Site Boundary AT

.81 MILES SSE ANNUAL BETA AIR DOSE - 6.79E-02 MIL1RADS ANNUAL GAM4MA AIR DOSE -

1.03E-01 MILIRIADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+_____-____+_______-__+__________+__________+__________+__________+___----+-+-+__-______+

PLUME 6.87E-02 : 6.87E-02 : 6.87E-02 : 6.87E-02

6.87E-02 : 6.87E-02 : 6.94E-02
1.31E-01

-________+_____-____+________-_+__________+__________+__________+__________+___--+

____+__-___

_+

GROUND 1.70E-03 : 1.70E-03 : 1.70E-03 : 1.70E-03 : 1.70E-03 : 1.70E-03 : 1.70E-03 : 2.OOE-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 3.77E-05 2.68E-04 2.01E-04 2.75E-05 2.OOE-05 3.47E-03 4.74E-09 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

TEEN

5.87E-05 : 2.90E-04 : 3.32E-04 : 4.17E-05 : 3.01E-05 : 4.66E-03 : 8.14E-09 : O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______-+___-__+

CHILD

1.20E-04 : 1.95E-04 : 8.11E-04 : 6.61E-05 : 4.80E-05 : 8.93E-03 : 1.18E-08 : 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 6.99E-06 5.83E-05 2.12E-06 3.43E-06 5.11E-07 9.28E-05 1.68E-10 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-____+____-+__-__+

TEEN

5.53E-06 : 3.14E-05 : 1.79E-06 : 2.67E-06 : 4.16E-07 : 6.72E-05 : 1.49E-10 : O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-______-+____-__+

CHILD

8.60E-06 : 1.59E-05 : 3.38E-06 : 3.20E-06 : 5.25E-07 : 1.01E-04 : 1.68E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT

6.34E-06 1.69E-05 1.47E-05 8.95E-06 1.41E-05 2.62E-03 5.31E-10 O.00E+00

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-___-+___-__+

TEEN

1.07E-05 : 2.05E-05 : 2.69E-05 : 1.58E-05 : 2.51E-05 : 4.14E-03 : 1.01E-09 : O.OOE+00

-________+

__________+______

___+__________+_

________+_______

__+_______-

+----

-+

CHILD

2.06E-05 : 1.43E-05 : 6.61E-05 : 2.74E-05 : 4.18E-05 : 8.22E-03 : 1.46E-09 : O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_____---+-_+_____-+__+

INFANT : 3.77E-05 : 1.31E-05 : 1.30E-04 : 6.61E-05 : 7.27E-05 : 2.OOE-02 : 2.97E-09 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

6.23E-06 7.47E-06 2.56E-05 9.93E-06 1.69E-05 3.14E-03 6.37E-11 O.OOE+00

-________+_______--_+-_________+__________+__________+__________+__________+___--+-+-____+______+

TEEN

1.05E-05 : 9.88E-06 : 4.70E-05 : 1.76E-05 : 3.01E-05 : 4.97E-03 : 1.21E-10 : O.OOE+00

-________+_______--_+-_________+__________+__________+__________+__________+___--+-+-+-__+______+

CHILD

2.01E-05 : 7.71E-06 : 1.16E-04 : 3.07E-05 : 5.01E-05 : 9.86E-03 : 1.76E-10 : O.OOE+00

-________+_______--_+-_________+__________+__________+__________+__________+___--+-+-+-__+______+

INFANT : 3.80E-05 : 7.57E-06 : 2.26E-04 : 7.51E-05 : 8.71E-05 : 2.40E-02 : 3.56E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT

7.44E-07 : 6.20E-06 8.23E-07 1.33E-06 1.53E-06 : 1.98E-04 : 1.11E-04 O.OOE+00

-________+_______--_+-_________+__________+__________+__________+__________+___----+-+-+_-_______+

TEEN

9.92E-07 : 8.16E-06 : 1.16E-06 : 1.81E-06 : 2.11E-06 : 2.49E-04 : 1.62E-04 : O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

CHILD

1.12E-06 : 2.69E-05 : 1.59E-06 : 1.71E-06 : 1.97E-06 : 2.89E-04 : 1.32E-04 : O.OOE+00

-________+___

__+

_+_

+__

__+

_+_--+-

+

-______+-

+__-

_ +

INFANT : 7.23E-07 : 2.28E-05 : 1.20E-06

1.46E-06 : 1.29E-06 : 2.65E-04 : 8.54E-05 : O.OOE+00 4-4 4--

I

TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (HREM), APRIL-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

3 A Nearest Resident AT

.90 MILES NW ANNUAL BETA AIR DOSE = 2.56E-02 MILLRADS ANNUAL GAM4A AIR DOSE -

3.63E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

-______+-

+ __-_

_ +

PLUME

2.42E-02 : 2.42E-02 : 2.42E-02 : 2.42E-02 : 2.42E-02 : 2.42E-02 : 2.45E-02 : 4.83E-02

-+__________+__________+

_________+__________+_

________+__________+_--+

-______+_+_+-_

_+

GROUND

8.63E-04 : 8.63E-04 : 8.63E-04 : 8.63E-04 : 8.63E-04 : 8.63E-04 : 8.63E-04 : 1.02E-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 2.92E-05 1.79E-04 3.39E-04 1.99E-05 2.04E-05 3.68E-03 4.25E-09 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+__-_

_ +

TEEN

4.56E-05 : 2.OOE-04 : 5.62E-04 : 3.OOE-05 : 3.07E-05 : 4.94E-03 : 7.49E-09 0.OOE+00

_________+-_________+________-_+________-_+_________-+_________-+________-_+________-_+________-_+

CHILD

9.64E-05 : 1.41E-04 : 1.37E-03 : 4.85E-05 : 4.90E-05 : 9.47E-03 : 1.10E-08 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 3.67E-06 2.99E-05 3.52E-06 1.88E-06 5.27E-07 9.82E-05 1.55E-10 0.OOE+00

_________+-_________+_______-__+________-_+_________-+_________-+________-_+________-_+________-_+

TEEN

2.91E-06 : 1.62E-05 : 2.97E-06 : 1.47E-06 : 4.30E-07 : 7.11E-05 : 1.42E-10 0.OOE+00

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

CHILD

4.53E-06 : 8.21E-06 : 5.61E-06 : 1.78E-06 : 5.44E-07 : 1.07E-04 : 1.63E-10 0.OOE+00 7

COW MILK :

ADULT : 6.11E-06 1.19E-05 2.16E-05 9.23E-06 1.52E-05 2.79E-03 3.32E-10 0.OOE+00 TEEN

1.03E-05 : 1.50E-05 : 3.95E-05 : 1.64E-05 : 2.71E-05 : 4.43E-03 : 6.41E-10 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+

-________+-

+__-

_ +

CHILD

1.99E-05 : 1.10E-05 : 9.73E-05 : 2.84E-05 : 4.51E-05 : 8.80E-03 : 9.43E-10 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+

-____+___+_+-_

_+

INFANT : 3.70E-05 : 1.04E-05 : 1.90E-04 : 6.91E-05 : 7.85E-05 : 2.14E-02 : 1.99E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

6.91E-06 9.22E-06 3.95E-05 1.07E-05 1.82E-05 3.35E-03 3.99E-11 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+-

+

+

-__+___+-_

_+

TEEN

1.17E-05 : 1.25E-05 : 7.26E-05 : 1.89E-05 : 3.25E-05 : 5.31E-03 : 7.69E-11 0.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+__-

_ +

CHILD

2.28E-05 : 9.95E-06 : 1.79E-04 : 3.30E-05 : 5.41E-05 : 1.06E-02 : 1.13E-10 0.OOE+00

_________+_________+________+_________+________+__________________+_--+-

+

+

+

+

+

+__-

_+

INFANT : 4.31E-05 : 9.92E-06 : 3.47E-04 : 8.08E-05 : 9.41E-05 : 2.57E-02 : 2.39E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 7.25E-07 2.78E-06 1.OOE-06 1.42E-06 1.51E-06 1.12E-04 3.82E-05 0.OOE+00

_________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

TEEN

9.84E-07 : 3.80E-06 : 1.42E-06 : 1.94E-06 : 2.08E-06 : 1.43E-04 : 5.63E-05 0.OOE+00

_______-_+-_________+____-_____+________-_+________-_+________-_+________-_+________-_+________-_+

CHILD

1.18E-06 : 1.24E-05 : 1.93E-06 : 1.88E-06 : 1.94E-06 : 1.70E-04 : 4.59E-05 0.OOE+00

_________+______-___+________-_+________-_+_________-+________-_+________-_+________-_+________-_+

INFANT : 8.14E-07 : 1.11E-05 : 1.46E-06 : 1.70E-06 : 1.28E-06 : 1.55E-04 : 3.05E-05 0.OOE+00

+-----------+-----------+

+-

+

-++

+

+

TABLE 2.

DOSES TO MAXIMUM INDIVIDUAL (REM

, APRIL-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 4.84E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 5.81E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_---+-______-+____-__+

PLUM

3.88E-03
3.88E-03 : 3.88E-03 : 3.88E-03 : 3.88E-03
3.88E-03 : 3.93E-03 : 8.64E-03

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

GROUND

4.10E-05 : 4.10E-05 : 4.10E-05 : 4.10E-05 : 4.10E-05
4.10E-05 : 4.10E-05 : 4.83E-05

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.60E-06 9.45E-06 2.13E-05 1.07E-06 1.19E-06 2.17E-04 2.42E-10 0.00E+00

-________+__________+__________+__________+__________+__________+__________+_---______+__-+___-__+

TEEN

2.51E-06 : 1.07E-05 : 3.53E-05 : 1.62E-06 : 1.79E-06 : 2.91E-04 : 4.29E-10 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-__+___+___+-___+

CHILD 5.35E-06 7.61E-06 8.61E-05 2.63E-06 : 2.87E-06 : 5.57E-04 : 6.33E-10 0.00E+00 MEAT ADULT 1.77E-07 1.43E-06 2.21E-07 9.24E-08 3.08E-08 5.77E-06 8.91E-12 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

TEEN

1.40E-07 : 7.71E-07 : 1.86E-07 : 7.23E-08 : 2.51E-08 : 4.18E-06 : 8.19E-12 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

CHILD

2.19E-07 : 3.93E-07 : 3.51E-07 : 8.79E-08 : 3.19Z-08 : 6.31E-06 : 9.43Z-12 0.00E+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT : 3.53E-07 6.38E-07 1.33E-06 5.40E-07 8.97E-07 1.65E-04 1.71E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

TEEN

5.96E-07 : 8.12E-07 : 2.44E-06 : 9.58E-07 : 1.60E-06 : 2.61E-04 : 3.33E-11 : O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

CHILD

1.15E-06 : 6.05E-07 : 6.01E-06 : 1.67E-06 : 2.66E-06 : 5.18E-04 : 4.91E-11 0.00E+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

INFANT : 2.15E-06 : 5.76E-07 : 1.17E-05 : 4.06E-06 : 4.63E-06 : 1.26E-03 : 1.05E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT : 4.10E-07 5.56E-07 2.45E-06 6.29E-07 1.08E-06 1.97E-04 2.06E-12 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

TEEN

6.94E-07 : 7.53E-07 : 4.51E-06 : 1.12E-06 : 1.92E-06 : 3.13E-04 : 3.99E-12 0.00E+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

1.36E-06 : 6.04E-07 : 1.11E-05 : 1.95E-06 : 3.19E-06 : 6.22E-04 : 5.90E-12 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

INFANT : 2.57E-06 : 6.03E-07 : 2.15E-05 : 4.77E-06 : 5.56E-06 : 1.51E-03 : 1.26E-11 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT

3.20E-07 : 6.34E-07 4.79E-07 : 6.48E-07 : 6.70E-07 3.53E-05 : 4.25E-06 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

TEEN

4.38E-07 : 9.21E-07 : 6.77E-07 : 8.91E-07 : 9.23E-07 : 4.57E-05 : 6.45E-06 : 0.00E+00

-________+______--+__________+_________-+__________+__________+__________+__________--+___---____+

CHILD

5.35E-07 : 2.95E-06 : 9.23E-07 : 8.70E-07 : 8.62E-07 : 5.55E-05 : 5.36E-06 : 0.00E+00

-________+______--+__________+_________-+__________+__________+__________+__________--+___---____+

INFANT : 3.79E-07 : 2.88E-06 : 7.00E-07 : 8.03E-07 : 5.67E-07 : 5.08E-05 : 3.92E-06 : 0.00E+00

+-----------+-----------+-----------+--------+-+-+

+-+

II

TABLE 2.

DOSES TO MAXIMUM INDIVIDUAL (MREM, APRIL-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

5 A Nearest Garden AT 1.00 MILES W

ANNUAL BETA AIR DOSE = 1.53E-02 MILLRADS ANNUAL GAMMA AIR DOSE = 1.88E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+_________-+__________+_________-+________-_+________-_+________-_+________-_+

PLUME

1.25E-02 : 1.25E-02 : 1.25E-02 : 1.25E-02 : 1.25E-02 : 1.25E-02 : 1.27E-02 : 2.75E-02

-________+__________+__________+__________+__________+__________+__________+_____--+-+-_++____-+_+

GROUND

3.56E-04 : 3.56E-04 : 3.56E-04 : 3.56E-04 : 3.56E-04 : 3.56E-04 : 3.56E-04 : 4.19E-04

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.36E-05 8.05E-05 1.77E-04 9.12E-06 1.00E-05 1.81E-03 2.04E-09 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_____--+-+-+-__+__-+_+

TEEN

2.12E-05 : 9.07E-05 : 2.93E-04 : 1.38E-05 : 1.50E-05 : 2.44E-03 : 3.61E-09 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_____--+-+-_+_____-+_+

CHILD

4.52E-05 : 6.46E-05 : 7.15E-04 : 2.23E-05 : 2.40E-05 : 4.67E-03 : 5.33E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

NEAT ADULT 1.53E-06 1.24E-05 1.83E-06 7.97E-07 2.59E-07 4.84E-05 7.49E-11 0.00E+00

-________+__________+__________+__________+__________+__________+__________+_____--+-+-+-_____-+_+

TEEN

1.21E-06 : 6.69E-06 : 1.54E-06 : 6.24E-07 : 2.11E-07 : 3.50E-05 : 6.89E-11 : 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_____--+-+-+-_____-+_+

CHILD

1.89E-06 : 3.40E-06 : 2.92E-06 : 7.57E-07 : 2.67E-07 : 5.29E-05 : 7.92E-11 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT

2.97E-06 5.42E-06 1.11E-05 4.53E-06 7.51E-06 1.38E-03 1.47E-10 0.00E+00

-________+______-___+_________-+_________-+_________-+-_________+__________+-_________+_________-+

TEEN

5.01E-06 : 6.89E-06 : 2.03E-05 : 8.03E-06 : 1.34E-05 : 2.19E-03 : 2.84E-10 0.OOE+00

-________+______-___+__________+_________-+________-_+________-_+_______-__+________-_+________-_+

CHILD

9.66E-06 : 5.12E-06 : 5.OOE-05 : 1.40E-05 : 2.23E-05 : 4.34E-03 : 4.20E-10 0.OOE+00

-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+

INFANT : 1.80E-05 : 4.87E-06 : 9.76E-05 : 3.40E-05 : 3.88E-05 : 1.06E-02 : 8.98E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT : 3.43E-06 4.64E-06 2.04E-05 5.27E-06 9.01E-06 1.65E-03 1.76E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

TEEN

5.81E-06 : 6.29E-06 : 3.75E-05 : 9.36E-06 : 1.61E-05 : 2.62E-03 : 3.41E-11 : O.00E+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

CHILD

1.13E-05 : 5.04E-06 : 9.25E-05 : 1.63E-05 : 2.67E-05 : 5.21E-03 : 5.04E-11 : O.00E+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-__+_+-___+

INFANT : 2.15E-05 : 5.03E-06 : 1.79E-04 : 3.99E-05 : 4.65E-05 : 1.27E-02 : 1.08E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL:

ADULT 9.22E-07 1.96E-06 1.37E-06 : 1.86E-06 1.93E-06 : 1.05E-04 : 1.51E-05 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-__+______-+__-__+

TEEN

1.26E-06 : 2.82E-06 : 1.94E-06 : 2.56E-06 : 2.66E-06 : 1.36E-04 : 2.27E-05 : 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

CHILD

1.54E-06 : 9.06E-06 : 2.64E-06 : 2.50E-06 : 2.49E-06 : 1.65E-04 : 1.88E-05 : 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

INFANT : 1.09E-06 : 8.74E-06 : 2.OOE-06 : 2.30E-06 : 1.63E-06 : 1.51E-04 : 1.35E-05 : 0.OOE+00

- - - + -

- - - - - + - - -

+

4-4 IOT 00

TABLE 3.

DOSES TO MAXIMMM INDIVIDUAL OeMIU

, JANUARY-JUNE 2003 SPECIAL LOCATION NO.

1 A Site Boundary AT

.69 MILES NNW ANNUAL BETA AIR DOSE = 7.32E-02 MILLRADS ANNUAL GIMMA AIR DOSE -

1.11E-01 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-+-+-+___-__+

PLUMZ

7.40E-02 : 7.40E-02 : 7.40E-02 : 7.40E-02 : 7.40E-02 : 7.40E-02 : 7.48E-02 : 1.41E-01 :

-________+__________+__________+__________+__________+__________+__________+_--+-______+_+_+-___+

GROUND

3.31E-03 : 3.31E-03 : 3.31E-03 : 3.31E-03
3.31E-03 : 3.31E-03 : 3.31E-03 : 3.90E-03 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 6.94E-05 5.03E-04 2.65E-04 5.32E-05 3.68E-05 6.31E-03 7.08E-09 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+

TEEN

1.O0E-04 : 5.41E-04 : 4.39E-04 : 8.09E-05
5.56E-05 : 8.49E-03 : 1.21E-08 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

CHILD

2.18E-04 : 3.60E-04 : 1.07E-03 : 1.28E-04
8.84E-05 : 1.63E-02 : 1.76E-08 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MZAT ADULT 1.36E-05 1.14E-04 2.87E-06 6.68E-06 9.41E-07 1.69E-04 2.51E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

TEEN

1.08E-05 : 6.11E-05 : 2.42E-06 : 5.20E-06 : 7.66E-07 : 1.23Z-04 : 2.22E-10 0.OOE+00 :

CHILD

1.67E-05 : 3.09E-05 : 4.56E-06 : 6.23E-06 : 9.65E-07 : 1.85E-04 : 2.49E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT

1.16E-05 3.14E-05 2.20E-05 1.63E-05 2.54E-05 4.75E-03 8.14E-10 0.OOE+00

-________+______-___+_________-+__________+__________+__________+__________+

-_________+__-

+

TEEN

1.95E-05 : 3.80E-05 : 4.02E-05 : 2.87E-05 : 4.53E-05
7.52E-03 : 1.54E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

3.75E-05 : 2.63E-05 : 9.87E-05 : 4.96E-05 : 7.53E-05 : 1.49E-02 : 2.24E-09 0.OOE+00 :

INFANT 6.83E-05 2.39E-05 : 1.96E-04 : 1.20E-04 : 1.31E-04 : 3.62E-02 : 4.53E-09 0.OOE+00

+---------+----------------

+--

GOATMILK ADULT 1.10E-05 1.20E-05 3.68E-05 1.79E-05 3.04E-05 5.70E-03 9.77E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_____--+-+-+-_____-__+

TEEN

1.86E-05 : 1.58E-05 : 6.74E-05 : 3.18E-05 : 5.43E-05 : 9.02E-03 : 1.85E-10 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

CHILD

3.52E-05 : 1.22E-05 : 1.66E-04 : 5.54E-05 : 9.02E-05 : 1.79E-02 : 2.69E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INFANT : 6.65E-05 : 1.19E-05 : 3.25E-04 : 1.35E-04 : 1.57E-04 : 4.34E-02 : 5.44E-10 0.OOE+00 :

n;HAL ADULT

1.62E-06 1.55E-05 1.65E-06 : 2.99E-06 3.58E-06 4.33E-04 2.41E-04 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

TEEN

2.16E-06 : 2.58E-05 : 2.33E-06 : 4.05E-06 : 4.90E-06 : 5.44E-04
3.53E-04 : 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

2.44E-06 : 9.78E-05 : 3.17E-06 : 3.82E-06 : 4.56E-06 : 6.30E-04
2.87E-04 : 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

INFANT : 1.56E-06 : 8.12E-05 : 2.42E-06 : 3.23E-06 : 2.97E-06 : 5.77E-04 : 1.88E-04 : 0.OOE+00 :


+----------------

+-- ---

+-

+

+

'.0

TABLE 3.

DOSES TO MAXIMUM INDIVIDUAL (MEEM, JANUARY-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

2 A Site Boundary AT

.67 MILES N

ANNUAL BETA AIR DOSE = 9.14E-02 MILLRADS ANNUAL GAMMAL AIR DOSE = 1.39E-01 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_--+-____+___+_+-___+

PLUME

9.24E-02 : 9.24E-02 : 9.24E-02 : 9.24E-02 : 9.24E-02 : 9.24E-02 : 9.34E-02 : 1.76E-01 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-__+___+-___+

GROUND

4.73E-03 : 4.73E-03 : 4.73E-03 : 4.73E-03 : 4.73E-03
4.73E-03 : 4.73E-03 : 5.57E-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.01E-04 7.27E-04 4.24E-04 7.72E-05 5.44E-05 9.37E-03 1.05E-08 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

TEEN

1.57E-04 : 7.83E-04 : 7.01E-04 : 1.17E-04 : 8.23E-05 : 1.26E-02 : 1.80E-08 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

CHILD

3.19E-04 : 5.23E-04 : 1.71E-03 : 1.85E-04 : 1.31E-04 : 2.42E-02 : 2.61E-08 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.94E-05 1.62E-04 4.57E-06 9.57E-06 1.39E-06 2.51E-04 3.73E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-__+______-+__-__+

TEEN

1.54E-05 : 8.74E-05 : 3.84E-06 : 7.45E-06 : 1.13E-06 : 1.82E-04 : 3.30E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

2.39E-05 : 4.42E-05 : 7.25E-06 : 8.93E-06 : 1.43E-06 : 2.75E-04 : 3.72E-10 : O.OOE+00 :

COW MILX:

ADULT

1.71E-05 4.55E-05 3.41E-05 2.41E-05 3.78E-05 7.05E-03 1.18E-09 O.OOE+00 O

+

+----

__+_-----

+

TEEN

2.88E-05 : 5.52E-05 : 6.24E-05 : 4.26E-05 : 6.74E-05 : 1.12E-02 : 2.23E-09 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-___-+___-__+

CHILD

5.53E-05 : 3.83E-05 : 1.53E-04 : 7.36E-05 : 1.12E-04 : 2.21E-02 : 3.24E-09 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

INFANT : 1.01E-04 : 3.48E-05 : 3.04E-04 : 1.78E-04 : 1.95E-04 : 5.38E-02 : 6.57E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

1.65E-05 1.82E-05 5.75E-05 2.66E-05 4.52E-05 8.46E-03 1.41E-10 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---______+__-+___-__+

TEEN

2.77E-05 : 2.40E-05 : 1.06E-04 : 4.73E-05 : 8.07E-05 : 1.34E-02 : 2.67E-10 0.OOE+00 :

-_______+_____-____+__________+__________+__________+__________+__________+___--+-______-+___-___+

CHILD

5.27E-05 : 1.86E-05 : 2.60E-04 : 8.23E-05 : 1.34E-04 : 2.66E-02 : 3.89E-10 0.OOE+00 :

-_______+_____-____+__________+__________+__________+__________+__________+___--_______--+___-___+

INFANT : 9.94E-05 : 1.81E-05 : 5.09E-04 : 2.01E-04 : 2.33E-04 : 6.45E-02 : 7.89E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 2.04E-06 1.96E-05 2.06E-06 : 3.75E-06 4.48E-06 : 5.45E-04 3.06E-04 0.OOE+00

-________+______-___+_________-+_________-+_________-+-_________+__________+_________-+________-_+

TEEN

2.71E-06 : 3.27E-05 : 2.90E-06 : 5.07E-06 : 6.13E-06 : 6.84E-04 : 4.50E-04 : O.OOE+00 :

-________+_____-____+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

CHILD

3.06E-06 : 1.24E-04 : 3.95E-06 : 4.79E-06 : 5.70E-06 : 7.92E-04 : 3.65E-04 : O.OOE+00 :

-________+_____-____+________-_+_________-+_________-+_________-+__________+-_________+_________-+

INFANT : 1.95E-06 : 1.03E-04 : 3.02E-06 : 4.05E-06 : 3.72E-06 : 7.25E-04 : 2.39E-04 : O.OOE+00

- - + -

- - - - - + - - -

+ -- -

4

TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM, JANUARY-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

3 A Nearest Resident AT

.90 MILES NW ANNUAL BETA AIR DOSE -

2.37E-02 MIIIRADS ANNUAL GAMMA AIR DOSE -

3.43E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

_______-_+-_________+_____-____+_________-+__________+__________+__________+_________-+________-_+

PLUME

2.29E-02 : 2.29E-02 : 2.29E-02 : 2.29E-02 : 2.29E-02
2.29E-02 : 2.31E-02 : 4.50E-02 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GROUND

1.19E-03 : 1.19E-03 : 1.19E-03 : 1.19E-03 : 1.19E-03 : 1.19E-03 : 1.19E-03 : 1.40E-03 :

VEGET ADULT 3.05E-05 2.05E-04 2.28E-04 2.23E-05 1.88E-05 3.31E-03 3.64E-09 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __-_

_ +

TEEN

4.75E-05 : 2.24E-04 : 3.78E-04 : 3.38E-05 : 2.83E-05 : 4.45E-03 : 6.35E-09 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

-____+__-

+ __-_

_ +

CHILD

9.82E-05 : 1.53E-04 : 9.24E-04 : 5.40E-05 : 4.51E-05 : 8.52E-03 : 9.30E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 4.95E-06 4.10E-05 2.40E-06 2.47E-06 4.83E-07 8.85E-05 1.32E-10 0.OOE+00

_________+_______-__+__________+______--+ -

__+__________+_________+_____________--+

+

-___+-____

_+

TEEN

3.92E-06 : 2.21E-05 : 2.03E-06 : 1.93E-06 : 3.94E-07 : 6.41E-05 : 1.19E-10 0.OOE+00 :

_________+_______-__+__________+______--+ -

__+__________+_________+_____________--+

+

-___+-____

_+

CHILD

6.09E-06 : 1.12E-05 : 3.82E-06 : 2.32E-06 : 4.97E-07 : 9.68E-05 : 1.36E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

Cow MILK :

ADULT

5.73E-06 1.31E-05 1.57E-05 8.36E-06 1.35E-05 2.50E-03 3.30E-10 0.OOE+00

++++

+

+-+-_______+

TEEN

9.67E-06 : 1.62E-05 : 2.89E-05 : 1.48E-05 : 2.40E-05 : 3.96E-03 : 6.32E-10 0.OOE+00 :

CHILD

1.86E-05 : 1.15E-05 : 7.09E-05 : 2.57E-05 : 3.99E-05 : 7.85E-03 : 9.25E-10 : O.OOE+00 :

_________+ ______

___+__

+_____

____+

__+___

___+_---________+- +___- _

_ +

INFANT : 3.42E-05 : 1.06E-05 : 1.39E-04 : 6.22E-05 : 6.95E-05 : 1.91E-02 : 1.92E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

6.01E-06 7.32E-06 2.80E-05 9.47E-06 1.61E-05 3.OOE-03 3.96E-11 O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+___- _

_ +

TEEN

1.01E-05 : 9.78E-06 : 5.14E-05 : 1.68E-05 : 2.88E-05 : 4.75E-03 : 7.58E-11 : O.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+

+

+

+___- _

_ +

CHILD

1.95E-05 : 7.71E-06 : 1.27E-04 : 2.93E-05 : 4.79E-05 : 9.42E-03 : 1.11E-10 0.OOE+00 :

_________+ ______

___+__

+_____

____+

__+___

___+_---________- +____- _

_ +

INFANT : 3.69E-05 : 7.62E-06 : 2.46E-04 : 7.16E-05 : 8.33E-05 : 2.29E-02 : 2.30E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHA ADULT : 7.77E-07 : 4.88E-06 9.73E-07 1.49E-06 : 1.68E-06 : 1.53E-04 6.71E-05 0.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

-__+

_+

TEEN

1.05E-06 : 8.19E-06 : 1.37E-06 : 2.04E-06 : 2.30E-06 : 1.94E-04 : 9.87E-05 : 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+

+___- _

_ +

CHILD

1.22E-06 : 3.15E-05 : 1.87E-06 : 1.96E-06 : 2.15E-06 : 2.27E-04 : 8.04E-05 : O.00E+00 :

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+

+

+

+___- _

_ +

INFANT : 8.25E-07 : 2.67E-05 : 1.42E-06 : 1.73E-06 : 1.40E-06 : 2.08E-04 : 5.31E-05 0.OOE+00 :

+- ----

+

4-----------4-4.

I------+--

A.

TABLE 3.

DOSES TO MAXIMuM INDIVIDUAL

($MM, JANUARY-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

4 A

Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 3.69E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 3.45E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+

-__+-_

_+

PLUME

2.30E-03 : 2.30E-03 : 2.30E-03 : 2.30E-03 : 2.30E-03 : 2.30E-03 : 2.34E-03 : 5.72E-03 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+ ___-_

_ +

GROUND

6.70E-05 : 6.70E-05 : 6.70E-05 : 6.70E-05 : 6.70E-05 : 6.70E-05 : 6.70E-05 : 7.88E-05 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.95E-06 1.26E-05 1.86E-05 1.39E-06 1.29E-06 2.30E-04 2.52E-10 O.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_---+

+

+___- _

_ +

TEEN

3.05E-06 : 1.39E-05 : 3.08E-05 : 2.11E-06 : 1.95E-06 : 3.10E-04 : 4.43E-10 : O.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_---________+-

+ ___-_

_ +

CHILD

6.37E-06 : 9.63E-06 : 7.52E-05 : 3.38E-06 : 3.11E-06 : 5.93E-04 : 6.51E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 2.81E-07 2.31E-06 1.94E-07 1.42E-07 3.33E-08 6.16E-06 9.19E-12 O.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+

+

+__-

_ +

TEEN

2.23E-07 : 1.25E-06 : 1.64E-07 : 1.11E-07 : 2.72E-08 : 4.46E-06 : 8.38E-12 : O.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+__-

_ +

CHILD

3.47E-07 : 6.33E-07 : 3.09E-07 : 1.34E-07 : 3.44E-08 : 6.73E-06 : 9.61E-12 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COw MILK :

ADULT : 3.89E-07 8.17E-07 1.22E-06 5.78E-07 9.41E-07 1.74E-04

2.0 2E-11

0.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

-__+

_+

TEEN

6.57E-07 : 1.02E-06 : 2.24E-06 : 1.02E-06 : 1.68E-06 : 2.76E-04 : 3.88E-11 0.00E+00 :

_________+______

___+__

+_____

____+

__+___

___+_---________+- +___- _

_ +

CHILD

1.26E-06 : 7.35E-07 : 5.51E-06 : 1.78E-06 : 2.79E-06 : 5.48E-04 : 5.71E-11 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

+

+__-

_ +

INFANT : 2.34E-06 : 6.87E-07 : 1.08E-05 : 4.31E-06 : 4.86E-06 : 1.33E-03 : 1.20E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

4.25E-07 5.40E-07 2.21E-06 6.61E-07 1.13E-06 2.09E-04 2.42E-12 0.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

-______+-

+__-

_ +

TEEN

7.18E-07 : 7.26E-07 : 4.06E-06 : 1.17E-06 : 2.01E-06 : 3.31E-04 : 4.66E-12 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

+

+__-

_ +

CHILD

1.39E-06 : 5.76E-07 : 1.OOE-05 : 2.05E-06 : 3.35E-06 : 6.57E-04 : 6.85E-12 : O.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+

-________+-

+__-

_ +

INFANT : 2.63E-06 : 5.72E-07 : 1.94E-05 : 5.01E-06 : 5.83E-06 : 1.60E-03 : 1.44E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT

3.28E-07 : 9.90E-07 : 4.87E-07 6.54E-07 6.85E-07 4.20E-05 8.59E-06 O.00E+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

-__+

_+

TEEN

4.47E-07 : 1.56E-06 : 6.88E-07 : 8.99E-07 : 9.43E-07 : 5.39E-05 : 1.28E-05 : 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+

-________+-

+__-

_ +

CHILD

5.41E-07 : 5.48E-06 : 9.38E-07 : 8.76E-07 : 8.81E-07 : 6.46E-05 : 1.05E-05 : 0.OOE+00 :

_________+ ______

___+__

+_____

____+

__+___

___+_--+

+___- _

_ +

INFANT : 3.81E-07 : 4.96E-06 : 7.10E-07 : 8.03E-07 : 5.79E-07 : 5.92E-05 : 7.35E-06 : 0.OOE+00 :

4-- - -

- - +-

4-4 4-4 iol

TABLE 3.

DOSES TO MAXIMUM INDIVIDUAL (MREM),

JANUARY-JUNE 2003 (CONTINUED)

SPECIAL LOCATION NO.

5 A Nearest Garden AT 1.90 MILES NNW ANNUAL BETA AIR DOSE = 1.12E-02 M5LLLRADS ANNUAL GAMMA AIR DOSE = 1.56E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+

PLUME

1.04E-02 : 1.04E-02
1.04E-02 : 1.04E-02 : 1.04E-02 : 1.04E-02 : 1.05E-02 : 2.10E-02 :

-________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+________-_+

GROUND

2.78E-04 : 2.78E-04 : 2.78E-04 : 2.78E-04 : 2.78E-04 : 2.78E-04 : 2.78E-04 : 3.27E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 7.19E-06 4.82E-05 5.51E-05 5.25E-06 4.45E-06 7.86E-04 8.64E-10 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______-+___-__+

TEEN

1.12E-05 : 5.27E-05 : 9.12E-05 : 7.96E-06 : 6.72E-06 : 1.06E-03 : 1.51E-09 0.OOE+00 :

-________+______-___+_________-+________-_+_________-+_________-+__________+-_________+_________-+

CHILD

2.32E-05 : 3.61E-05 : 2.23E-04 : 1.27E-05 : 1.07E-05 : 2.02E-03 : 2.21E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

NEAT ADULT 1.16E-06 9.56E-06 5.79E-07 5.78E-07 1.15E-07 2.10E-05 3.13E-11 0.OOE+00

-________+__________+______--+ -

__+__________+_________+________+________+____--+

-____+-______

_+

TEEN

9.16E-07 S.16E-06 : 4.88E-07 : 4.51E-07 : 9.34E-08 : 1.52E-05 : 2.83E-11 : 0.OOE+00 :

-________+__________+______--+ -

__+__________+_________+________+________+____--+-

+

-__+-______

_+

CHILD

1.42E-06 : 2.61E-06 : 9.21E-07 : 5.43E-07 : 1.18E-07 : 2.30E-05 : 3.23E-11 0.OOE+00 :

s 1

+-------+-

+------+-----------------------------+----------+-_________+_--

+

COW MILK:

ADULT

1.36E-06 3.09E-06 3.78E-06 1.99E-06 3.20E-06 5.94E-04 7.75E-11 0.OOE+00

-+---------------------------------------+-

+

+-

+

-+-

+---

TEEN

2.29E-06 : 3.81E-06 : 6.93E-06 : 3.52E-06 : 5.71E-06 : 9.40E-04 : 1.48E-10 0.OOE+00 :

+-

+----------------------------+- -

+

+

+---

CHILD

4.40E-06 : 2.71E-06 : 1.70E-05 : 6.09E-06 : 9.49E-06 : 1.87E-03 : 2.17E-10 : O.OOE+00 :

-+------------+-

+----------------------------+- -

+

+

+---

INFANT : 8.12E-06 : 2.51E-06 : 3.35E-05 : 1.48E-05 : 1.65E-05 : 4.53E-03 : 4.52E-10 0.OOE+00 :

+-

+----------------------------+- -

+

+

+---

GOATMILK :

ADULT

1.43E-06 1.75E-06 6.73E-06 2.25E-06 3.84E-06 7.12E-04 9.30E-12 0.00E+00

-________+__________+--+--_______+__________+__________+__________+__________+_-----_____+___--__+

TEEN

2.41E-06 : 2.34E-06 : 1.24E-05 : 4.OOE-06 : 6.84E-06 : 1.13E-03 : 1.78E-11 0.OOE+00

-________+__________+--_--_______+__________+__________+__________+__________+_-----_____+___--__+

CHILD

4.65E-06 : 1.84E-06 : 3.05E-05 : 6.96E-06 : 1.14E-05 : 2.24E-03 : 2.61E-11 0.00E+00 :

-________+__________+--+--_______+__________+__________+__________+__________+_-----_____+___--__+

INFANT : 8.78E-06 : 1.82E-06 : 5.92E-05 : 1.70E-05 : 1.98E-05 : 5.44E-03 : 5.42E-11 0.OOE+00

-________+__________+--+--_______+__________+__________+__________+__________+_--+---_____+__--__+

INHAL ADULT 4.80E-07 2.28E-06 6.54E-07 9.41E-07 1.03E-06 7.86E-05 2.76E-05 0.OOE+00

+-


+-------------------+-

+

+

+---

TEEN

6.50E-07 : 3.87E-06 : 9.23E-07 : 1.29E-06 : 1.41E-06 : 1.OOE-04 : 4.07E-05 0.OOE+00

+-


+-------------------+-

+

+

+---

CHILD

7.73E-07 : 1.50E-05 : 1.26E-06 : 1.25E-06 : 1.31E-06 : 1.18E-04 : 3.32E-05 0.OOE+00

+-

+----------------------------+-

+

+

+--

INFANT : 5.32E-07 : 1.30E-05 : 9.55E-07 : 1.12E-06 : 8.61E-07 : 1.08E-04 : 2.23E-05 0.00E+00

- - + - -

4--

4

TABLE 4.

DOSES SPECIAL LOCATION NO.

1 A

Site Boundary AT

.69 MILES NNW ANNUAL BETA AIR DOSE - 5.24E-02 MILLRADS ANNUAL GAMM AIR DOSE -

8.01E-02 MILLRADS TO MAXIM[UM INDIVIDUAL (MRM),

JULY-SEPTEMBER 2003 Oil PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-_______+_____-____+_________-+________-_+________-_+_______-__+________-_+________-_+________-__

PLUME

5.33E-02
5.33E-02 : 5.33E-02 : 5.33E-02 : 5.33E-02 : 5.33E-02 : 5.38E-02 : 1.02E-01

-_______+__________+__________+__________+__________+__________+__________+___--_______--+-+__-__+

GROUND 7.85E-04 7.85E-04 : 7.85E-04 : 7.85E-04 : 7.85E-04 : 7.85E-04

7.85E-04 : 9.06E-04 VEGET ADULT 5.73E-05 2.98E-04 1.31E-03 3.OOE-05 4.86E-05 8.80E-03 1.76E-08 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--_______+-________+

TEEN

9.04E-05 : 3.56E-04
2.17E-03 : 4.40E-05 : 7.12E-05
1.17E-02 : 3.19E-08 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-______-+-+__-__+

CHILD

2.03E-04 : 2.77E-04 : 5.31E-03 : 7.31E-05 : 1.13E-04
2.23E-02 : 4.78E-08 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.84E-06 1.28E-05 1.37E-05 1.16E-06 1.19E-06 2.27E-04 6.65E-10 O.OOE+00

-_________+__________+__________+_________+__________+__________+__________+__--+_______+-_______+

TEEN

1.46E-06 : 7.23E-06 : 1.15E-05 : 9.27E-07 : 9.72E-07 : 1.65E-04 : 6.29E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

2.34E-06 : 3.92E-06
2.18E-05 : 1.18E-06 : 1.23E-06 : 2.49E-04 : 7.36E-10 : O.OOE+00 COW MIC LK ADULT
1.44E-05 2.27E-05 7.62E-05 2.41E-05 4.13E-05 6.99E-03 6.21E-10 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-+-+--+__-__+

TEEN

2.45E-05 : 3.10E-05
1.40E-04 : 4.28E-05 : 7.37E-05 : 1.11E-02 : 1.29E-09 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--____+___-+-+__-__+

CHILD

4.82E-05 : 2.54E-05
3.45E-04 : 7.48E-05 : 1.23E-04 : 2.24E-02 : 1.97E-09 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--_______-+--+__-__+

INFANT : 9.13E-05 : 2.56E-05

6.70E-04 : 1.84E-04 : 2.14E-04
5.45E-02 : 4.76E-09 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

1.85E-05 3.18E-05 1.44E-04 2.88E-05 4.95E-05 8.38E-03 7.46E-11 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-+-+--+__-__+

TEEN

3.17E-05 : 4.40E-05 : 2.65E-04 : 5.12E-05 : 8.84E-05 : 1.34E-02 : 1.54E-10 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--__+___+__--+__-__+

CHILD

6.37E-05 : 3.64E-05
6.53E-04 : 8.95E-05 : 1.47E-04
2.69E-02 : 2.36E-10 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--____+_+__--+__-__+

INFANT : 1.21E-04 : 3.68E-05

1.26E-03 : 2.20E-04 : 2.57E-04 : 6.54E-02
5.71E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INIIAL ADULT 1.25E-05 2.26E-05 : 1.71E-05 : 2.89E-05 3.61E-05

2.38E-03
6.27E-05 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-+-+--+__-__+

TEEN

1.72E-05 : 8.05E-05 : 2.40E-05 : 4.OOE-05 : 5.OOE-05
3.16E-03 : 1.03E-04 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-__+_-+__-__+

CHILD

2.10E-05 : 5.92E-04 : 3.27E-05 : 3.94E-05 : 4.70E-05 : 4.02E-03
8.93E-05 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-+-+--+__-__+

INFANT : 1.51E-05 : 5.34E-04 : 2.59E-05 : 3.69E-05 : 3.11E-05 : 3.71E-03 : 8.26E-05 : O.OOE+00

+----------+---------------------------------++--

-+-

+

+-+

TABLE 4.

DOSES TO MAXIMUM INDIVIDUAL

(

JEEM, JULY-SEPTEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

2 A

Site Boundary AT

.67 MILES N

ANNUAL BETA AIR DOSE = 6.17E-02 MIL1RADS ANNUAL GAMMA AIR DOSE = 9.43E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+______--+ -

__+__________+_________+________+________+____---

+

+

+-________+

PLUME 6.28E-02 : 6.28E-02 : 6.28E-02 : 6.28E-02 : 6.28E-02 : 6.28E-02 : 6.34E-02 : 1.20E-01 :

-________+__________+_____

____+__________+

_________+______

___+_____-

+-

+

+

+-__

+

GROUND 1.02E-03 : 1.02E-03 : 1.02E-03 : 1.02E-03 : 1.02E-03 : 1.02E-03 : 1.02E-03 : 1.17E-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 7.40E-05 3.82E-04 1.67E-03 3.99E-05 6.46E-05 1.17E-02 2.23E-08 O.OOE+00

-________+__________+______--+ -

__+__________+_________+________+________+____---

+

+

+-________+

TEEN 1.17E-04 : 4.56E-04 : 2.77E-03 : 5.84E-05 : 9.45E-05 : 1.55E-02 : 4.05E-08 0.OOE+00 :

-________+__________+_____

____+__________+

_________+______

___+_____--+-

+

+ -

+

+

+

+__

_+

CHILD 2.61E-04 : 3.54E-04 : 6.76E-03 : 9.72E-05 : 1.51E-04 : 2.97E-02 : 6.07E-08 0.00E+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

NEAT ADULT 2.43E-06 1.69E-OS 1.75E-05 1.55E-06 1.58E-06 3.02E-04 8.44E-10 O.OOE+00

-________+__________+______--+ -

__+__________+_________+________+________+____--+

-____+-_______+

TEEN

1.93E-06 : 9.52E-06 : 1.47E-05 : 1.23E-06 : 1.29E-06 : 2.19E-04 : 8.00E-10 : O.OOE+00 :

-________+__________+______--+ -

__+__________+_________+________+________+____--+-

+

+

+_-______+

CHILD

3.08E-06 : 5.15E-06 : 2.78E-05 : 1.57E-06 : 1.64E-06 : 3.30E-04 : 9.35E-10 : O.OOE+OO

-________+__________+______--__+-________+__________+__________+__________+____----____+_-_______+

COW MILX :

ADULT

1.91E-05 2.95E-05 9.79E-05 3.21E-05 5.49E-05 9.28E-03 7.89E-10 O.OOE+00

-________+__________+______--+ -

__+__________+_________+________+________+____---

+

-__+_-_______+

TEEN

3.24E-05 : 4.05E-05 : 1.80E-04 : 5.70E-05 : 9.80E-05 : 1.48E-02 : 1.63E-09 : O.OOE+00 :

-________+__________+______--+ -

__+__________+_________+________+________+____---____+_-_______+

CHILD

6.36E-05 : 3.32E-05 : 4.43E-04 : 9.95E-05 : 1.63E-04 : 2.98E-02 : 2.50E-09 : O.OOE+00 :

-________+__________+______--+ -

__+__________+_____

____+

____+

____+

____---____+_- ______

_+

INFANT : 1.20E-04 : 3.33E-05 : 8.62E-04 : 2.44E-04 : 2.85E-04 : 7.25E-02 : 6.04E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOAIMILX :::

ADULT

2.44E-05 4.12E-05 1.84E-04 3.83E-05 6.59E-05 1.11E-02 9.47E-11 O.OOE+00

-________+_____-____+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

TEEN

4.18E-05 : 5.70E-05 : 3.39E-04 : 6.81E-05 : 1.18E-04 : 1.77E-02 : 1.96E-10 : O.OOE+00 :

-________+_____-____+________-_+________-_+________-_+_________-+_________-+_________-+_________-+

CHILD

8.37E-05 : 4.72E-05 : 8.36E-04 : 1.19E-04 : 1.96E-04 : 3.58E-02 : 3.00E-10 0.OOE+00 :

-________+_____-____+_________-+_______-__+________-_+_________-+________-_+________-_+________-_+

INFANT 1.59E-04 : 4.77E-05 : 1.61E-03 : 2.92E-04 : 3.41E-04 : 8.70E-02 : 7.25E-10 : O.OOE+00 :

INHAL :

ADULT 1.46E-05 : 2.65E-05 : 2.OOE-05

3.39E-05 : 4.25E-05 2.83E-03 7.39E-05 : O.OOE+00

-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+

TEEN

2.OOE-05
9.43E-05 : 2.81E-05 : 4.68E-05 : 5.88E-05 : 3.75E-03 : 1.21E-04 : O.OOE+00 :

-________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

CHILD

2.46E-05 : 6.93E-04 : 3.83E-05 : 4.61E-05 : 5.53E-05 : 4.78E-03 : 1.05E-04 : O.OOE+OO

-________+______-___+_________-+_________-+________-_+_________-+________-_+________-_+________-_+

INFANT : 1.77E-05

6.24E-04 : 3.03E-05 : 4.31E-05 : 3.66E-05 : 4.41E-03 : 9.70E-05 : O.OOE+OO

+------+-----


4------

44--

4

++

It~

Ull

TABLE 4.

DOSES TO MAXIMUM INDIVIDUAL (NMEM),

JULY-SEPTEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

3 A

Nearest Resident AT

.90 MILES NW ANNUAL BETA AIR DOSE = 1.35E-02 MILLRADS ANNUAL GAMMA AIR DOSE = 1.98E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

PLUME

1.32E-02 : 1.32E-02 : 1.32E-02 : 1.32E-02 : 1.32E-02 : 1.32E-02 : 1.33E-02 : 2.60E-02 :

-________+__________+__________+__________+__________+__________+__________+_---______+__-+___-__+

GROUND 6.10E-04 : 6.10E-04 : 6.10E-04 : 6.10E-04 : 6.10E-04 : 6.10E-04 : 6.10E-04 : 7.OOE-04 :

VEGET ADULT 4.49E-05 2.57E-04 1.21E-03 1.53E-05 2.49E-05 4.55E-03 1.66E-08 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-+-_____-+___-__+

TEEN

7.21E-05 : 3.11E-04 : 2.OOE-03
2.25E-05 : 3.67E-05 : 6.05E-03
3.02E-08 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

1.67E-04 : 2.44E-04 : 4.90E-03 : 3.75E-05 : 5.86E-05 : 1.16E-02 : 4.52E-08 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.04E-06 7.52E-06 1.25E-05 5.64E-07 6.19E-07 1.18E-04 6.29E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

TEEN

8.34E-07 : 4.36E-06 : 1.06E-05 : 4.51E-07 : 5.06E-07 : 8.57E-05 : 5.95E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-___-+___-__+

CHILD

1.37E-06 : 2.45E-06 : 1.99E-05 : 5.79E-07 : 6.42E-07 : 1.29E-04 : 6.97E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT : 8.10E-06 1.60E-05 6.40E-05 1.22E-05 2.09E-05 3.58E-03 5.88E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---__+______-+___-__+

TEEN

1.38E-05 : 2.19E-05 : 1.18E-04 : 2.16E-05 : 3.72E-05 : 5.70E-03 : 1.22E-09 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-______-+___-__+

CHILD

2.78E-05 : 1.78E-05 : 2.90E-04 : 3.78E-05 : 6.20E-05 : 1.15E-02 : 1.86E-09 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-______-+___-__+

INFANT : 5.27E-05 : 1.79E-05 : 5.59E-04 : 9.27E-05 : 1.08E-04 : 2.79E-02 : 4.50E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

1.10E-05 2.44E-05 1.25E-04 1.46E-05 2.50E-05 4.30E-03 7.05E-11 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

TEEN

1.89E-05 : 3.37E-05 : 2.31E-04 : 2.59E-05 : 4.47E-05 : 6.84E-03 : 1.46E-10 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

CHILD

3.92E-05 : 2.76E-05 : 5.70E-04 : 4.52E-05 : 7.44E-05 : 1.38E-02 : 2.23E-10 0.00E+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

INFANT : 7.46E-05 : 2.79E-05 : 1.09E-03 : 1.11E-04 : 1.30E-04 : 3.34E-02 : 5.40E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHA ADULT 1.64E-05 2.34E-05 1.84E-05 3.23E-05 2.77E-05 : 4.95E-04 : 6.67E-05 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---______+__-+___-__+

TEEN

2.25E-05 : 1.03E-04 : 2.58E-05 : 4.45E-05 : 3.82E-05 : 6.56E-04 : 1.13E-04 : 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

2.79E-05 : 8.17E-04 : 3.51E-05 : 4.37E-05 : 3.59E-05 : 8.33E-04 : 1.OOE-04 : 0.00E+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

INFANT : 2.OOE-05 : 7.48E-04 : 2.78E-05 : 4.07E-05 : 2.37E-05 : 7.68E-04 : 1.OOE-04 : O.OOE+00 :

4-


+-

+


+---

+-+-+-+

0ba~

TABLE 4.

DOSES TO MAXn-AMN INDIVIDUAL (MREM, JULY-SEPTEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 2.47E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 2.82E-03 MILLRADS PATHAXW T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

PLUME

1.88E-03 : 1.88E-03 : 1.88E-03 : 1.88E-03
1.88E-03 : 1.88E-03 : 1.91E-03 : 4.19E-03 :

-________+______-___+________-_+_________-+_________-+__________+__________+_________-+________-_+

GROUND 3.59E-05 : 3.59E-05 : 3.59E-05 : 3.59E-05 : 3.59E-05 : 3.59E-05 : 3.59E-05 : 4.12E-05 :

VEGET ADULT 2.65E-06 1.55E-05 7.39E-05 7.85E-07 1.28E-06 2.35E-04 1.02E-09 O.OOE+OO

-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+

TEEN

4.27E-06 : 1.88E-05 : 1.23E-04 : 1.16E-06 : 1.89E-06 : 3.13E-04 : 1.85E-09 : O.OOE+OO :

-_______+_____-____+__________+__________+______--+

-__+

-_________+________+--+

+-_________+

CHILD 9.94E-06 : 1.47E-05 : 2.99E-04 : 1.93E-06 : 3.03E-06 : 5.99E-04 : 2.78E-09 : O.OOE+OO :

+

+--+-----

MEAT ADULT 5.56E-08 4.09E-07 7.65E-07 2.85E-08 3.21E-08 6.13E-06 3.86E-11 O.OOE+OO

-________+__________+__________+__________+__________+__________+__________+_---+-+-_____-+___-__+

TEEN

4.48E-08 : 2.39E-07 : 6.45E-07 : 2.28E-08 : 2.62E-08 : 4.44E-06 : 3.66E-11 : 0.00E+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

CHILD

7.44E-08 : 1.36E-07 : 1.22E-06 : 2.93E-08 : 3.33E-08 : 6.70E-06 : 4.28E-11 0.OOE+OO :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT

4.31E-07 9.14E-07 3.83E-06 6.20E-07 1.06E-06 1.84E-04 3.61E-11 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______-+___-__+

TEEN 7.39E-07 : 1.25E-06 : 7.05E-06 : 1.10E-06 : 1.90E-06 : 2.93E-04 : 7.47E-11 : O.OOE+00 :

-________+

__+

_+_

+__

__+

_+_-

+-____+__-+___

_ +

CHILD 1.50E-06 : 1.02E-06 : 1.74E-05 : 1.92E-06 : 3.16E-06 : 5.88E-04 : 1.14E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

INFANT : 2.84E-06 : 1.02E-06 : 3.35E-05 : 4.71E-06 : 5.50E-06 : 1.43E-03 : 2.76E-10 0.00E+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

5.96E-07 1.43E-06 7.57E-06 7.41E-07 1.27E-06 2.21E-04 4.33E-12 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

TEEN 1.03E-06 : 1.97E-06 : 1.39E-05 : 1.32E-06 : 2.27E-06 : 3.51E-04 : 8.96E-12 0.OOE+00 :

-________+___

__+

__+

_+ ___

_+_

_+_

+_--+

-__+______-

+__-

_ +

CHILD 2.16E-06 : 1.61E-06 : 3.44E-05 : 2.30E-06 : 3.79E-06 : 7.05E-04 : 1.37E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-____+___+_+-___+

INFANT : 4.10E-06 : 1.62E-06 : 6.59E-05 : 5.64E-06 : 6.60E-06 : 1.71E-03 : 3.32E-11 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT

7.85E-06 : 1.08E-05 8.58E-06 1.52E-05 1.21E-05 8.55E-05 3.09E-05 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

TEEN

1.08E-05 : 4.88E-05 : 1.21E-05 : 2.09E-05 : 1.68E-05 : 1.13E-04 : 5.26E-05 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

CHILD 1.34E-05 : 3.92E-04 : 1.64E-05 : 2.05E-05 : 1.57E-05 : 1.42E-04 : 4.68E-05 : O.OOE+00 :

-________+___

__+

_+_

+__

__+

_+_--+

-________+-

+__-

_ +

INFANT : 9.63E-06 : 3.59E-04 : 1.30E-05 : 1.91E-05 : 1.04E-05 : 1.31E-04 : 4.73E-05 : O.OOE+00 :

+----------+----------------------------------+-+----------++

+-+

III t'3

TABLE 4.

DOSES TO MNXXIUM INDIVIDUAL (MREM, JULY-SEPTEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

S A Nearest Garden AT 1.90 MILES NNW ANNUAL BETA AIR DOSE = 7.36E-03 MILLRADS ANNUAL GAMMA AIR DOSE = 1.08E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_---______+__-+___-__+

PLUMb

7.20E-03 : 7.20E-03 : 7.20E-03 : 7.20E-03 : 7.20E-03 : 7.20E-03 : 7.28E-03 : 1.42E-02 :

-________+__________+__________+__________+__________+__________+__________+_---+-+-_____-+___-__+

GROUND

1.14E-04 : 1.14E-04 : 1.14E-04 : 1.14E-04 : 1.14E-04 : 1.14E-04 : 1.14E-04 : 1.31E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 8.39E-06 4.79E-05 2.25E-04 2.90E-06 4.73E-06 8.63E-04 3.08E-09 0.OOE+00

-________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

TEEN

1.34E-05 : 5.78E-05 : 3.72E-04 : 4.27E-06 : 6.97E-06 : 1.15E-03 : 5.60E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

3.11E-05 : 4.53E-05 : 9.10E-04 : 7.11E-06 : 1.11E-05 : 2.20E-03 : 8.40E-09 : O.OOE+00 :

HEAT ADULT 1.96E-07 1.42E-06 2.33E-06 1.07E-07 1.17E-07 2.24E-05 1.17E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

TEEN

1.57E-07 : 8.22E-07 : 1.96E-06 : 8.58E-08 : 9.59E-08 : 1.62E-05 : 1.11E-10 : O.OOE+00 :

CHILD : 2.58E-07 : 4.61E-07 : 3.71E-06 : 1.1OE-07

1.22E-07 : 2.45E-05 : 1.29E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT : 1.53E-06 2.99E-06 1.19E-05 2.31E-06 3.96E-06 6.80E-04 1.09E-10 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______-+___-__+

TEEN

2.62E-06 : 4.10E-06 : 2.19E-05 : 4.11E-06 : 7.07E-06 : 1.08E-03 : 2.26E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+

CHILD : 5.25E-06 : 3.34E-06 : 5.41E-05 : 7.18E-06 : 1.18E-05 : 2.18E-03 : 3.45E-10 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

INFANT : 9.95E-06 : 3.35E-06 : 1.04E-04 : 1.76E-05 : 2.05E-05 : 5.29E-03 : 8.36E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK ADULT

2.07E-06 4.57E-06 : 2.33E-05 2.76E-06 4.75E-06 : 8.16E-04 1.31E-11 O.OOE+OO

-________+__________+__________+__________+__________+__________+__________+_---+-____+__-+___-__+

TEEN

3.57E-06 : 6.29E-06 : 4.29E-05 : 4.91E-06 : 8.48E-06 : 1.30E-03 : 2.71E-11 : O.OOE+OO :

-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+

CHILD

7.38E-06 : 5.15E-06 : 1.06E-04 : 8.59E-06 : 1.41E-05 : 2.61E-03 : 4.15E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

INFANT : 1.40E-05 : 5.21E-06 : 2.03E-04 : 2.11E-05 : 2.46E-05 : 6.34E-03 : 1.00E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 8.22E-06 1.18E-05 9.26E-06 : 1.63E-05 : 1.41E-05 2.70E-04 : 3.36E-05 : O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+

TEEN

1.13E-05 : 5.16E-05 : 1.30E-05 : 2.25E-05 : 1.94E-05 : 3.57E-04 : 5.69E-05 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-__+____-+___-__+

CHILD

1.40E-05 : 4.10E-04 : 1.77E-05 : 2.21E-05 : 1.82E-05 : 4.54E-04 : 5.04E-05 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+

INFANT : 1.O1E-05 : 3.75E-04 : 1.40E-05 : 2.05E-05 : 1.20E-05 : 4.18E-04 : 5.03E-05 : O.OOE+00 :

+----.-+-4--------

-+4---

+4.

I')

00

TABLE 5.

DOSES TO NAXIMUM INDIVIDUAL (MREM),

OCTOBER-DECEMBER 2003 SPECIAL LOCATION NO.

1 A

Site Boundary AT

.69 MIES NNW ANNUAL BETA AIR DOSE = 7.81E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 9.78E-05 MIL1RADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_--+-______+_+_+-___+

PLUME

6.55E-05 : 6.55E-05 : 6.55E-05 : 6.55E-05 : 6.55E-05 : 6.55E-05 : 6.63E-05 : 1.47E-04 :

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-+-+-+___-__+

GROUND

1.23E-04 : 1.23E-04 : 1.23E-04 : 1.23E-04 : 1.23E-04 : 1.23E-04 : 1.23E-04 : 1.45E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.79E-05 4.08E-05 1.17E-04 2.41E-05 3.99E-05 7.51E-03 1.01E-09 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_____--+-+-+-____+-+_+

TEEN

2.63E-05 : 4.67E-05 : 1.92E-04 : 3.61E-05 : 6.01E-05 : 1.01E-02 : 1.83E-09 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+____--+-___++_____-__+

CHILD

5.08E-05 : 3.45E-05 : 4.67E-04 : 6.07E-05 : 9.65E-05 : 1.93E-02 : 2.75E-09 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+____--+-____++____-__+

MEAT ADULT 8.67E-07 4.56E-06 1.44E-06 8.32E-07 1.05E-06 2.OOE-04 3.82E-11 0.00E+00

-+-----------------------------------------+-

+-

-+

+

+

+

+-

-+

TEEN

6.78E-07 : 2.49E-06 : 1.21E-06 : 6.68E-07 : 8.56E-07 : 1.45E-04 : 3.62E-11 0.00E+00 :

CHILD

1.02E-06 : 1.28E-06 : 2.28E-06 : 8.66E-07 : 1.09E-06 : 2.19E-04 : 4.23E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+_________--+__________+______-__+

COW MILK ADULT : 1.03E-05 7.26E-06 1.72E-05 1.81E-05 3.10E-05 5.70E-03 3.57E-11 0.00E+00

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

TEEN

1.72E-05 : 9.73E-06 : 3.13E-05 : 3.21E-05 : 5.53E-05 : 9.03E-03 : 7.39E-11 0.OOE+00 :

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

CHILD

3.21E-05 : 7.77E-06 : 7.63E-05 : 5.60E-05 : 9.19E-05 : 1.80E-02 : 1.13E-10 0.OOE+00 :

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

INFANT : 6.06E-05 : 7.67E-06 : 1.55E-04 : 1.37E-04 : 1.60E-04 : 4.36E-02 : 2.74E-10 0.00E+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

1.23E-05 8.29E-06 2.47E-05 2.17E-05 3.72E-05 6.84E-03 4.29E-12 0.OOE+00

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

TEEN

2.06E-05 : 1.13E-05 : 4.51E-05 : 3.85E-05 : 6.63E-05 : 1.08E-02 : 8.87E-12 0.OOE+00 :

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

CHILD

3.86E-05 : 9.19E-06 : 1.10E-04 : 6.71E-05 : 1.10E-04 : 2.15E-02 : 1.36E-11 0.OOE+00 :

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

INFANT : 7.31E-05 : 9.17E-06 : 2.22E-04 : 1.64E-04 : 1.92E-04 : 5.23E-02 : 3.28E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL:

ADULT : 1.59E-06 3.52E-06 2.67E-06 3.92E-06 6.77E-06 8.28E-04 1.27E-05 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

TEEN

2.12E-06 : 1.04E-05 : 3.77E-06 : 5.41E-06 : 9.36E-06 : 1.06E-03 : 2.OOE-05 : 0.00E+00 :

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

CHILD

2.41E-06 : 7.06E-05 : 5.13E-06 : 5.34E-06 : 8.80E-06 : 1.28E-03 : 1.70E-05 : 0.OOE+00 :

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

INFANT : 1.74E-06 : 6.17E-05 : 4.02E-06 : 4.99E-06 : 5.82E-06 : 1.18E-03 : 1.41E-05 : 0.OOE+00 :


+------------------------------

4-+---------4 I-4-----

+4 DTI Is-)

TABLE 5.

DOSES TO MAXIMUM INDIVIDUAL (MREM),

OCTOBER-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

2 A Site Boundary AT

.67 MILES N

ANNUAL BETA AIR DOSE = 8.96E-05 MILLRADS ANNUAL GAMMA AIR DOSE - 1.12E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+-_________+_________-+_________-+________-_+________-_+________-_+________-_+

PLUME

7.52E-05 : 7.52E-05 : 7.52E-05 : 7.52E-05 : 7.52E-05 : 7.52E-05 : 7.61E-05
1.68E-04 :

-________+_________+__________+_________-+__________+_________-+________-_+________-_+________-_+

GROUND

1.56E-04 : 1.56E-04 : 1.56E-04 : 1.56E-04 : 1.56E-04 : 1.56E-04 : 1.56E-04 : 1.83E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 2.43E-05 6.17E-05 1.96E-04 3.09E-05 5.12E-05 9.64E-03 2.10E-09 0.OOE+00

-________+______-___+________-_+________-_+_________-+_________-+__________+-_________+_________-+

TEEN

3.60E-05 : 7.14E-05 : 3.23E-04 : 4.64E-05 : 7.71E-05 : 1.30E-02 : 3.81E-09 : O.OOE+00 :

-________+_____-____+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

CHILD

7.06E-05 : 5.33E-05 : 7.87E-04 : 7.79E-05 : 1.24E-04 : 2.48E-02 : 5.71E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.12E-06 5.93E-06 2.33E-06 1.06E-06 1.35E-06 2.57E-04 7.94E-11 0.OOE+00

-________+______-___+________-_+________-_+________-_+________-_+_________-+-_________+_________-+

TEEN

8.76E-07 : 3.25E-06 : 1.96E-06 : 8.55E-07 : 1.10E-06 : 1.86E-04 : 7.52E-11 : O.OOE+00 :

-________+______-___+________-_+________-_+_________-+________-_+________-_+________-_+________-_+

CHILD

1.33E-06 : 1.69E-06 : 3.69E-06 : 1.11E-06 : 1.40E-06 : 2.81E-04 : 8.79E-11 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK

  • ADULT
1.32E-05 9.71E-06 2.42E-05 2.32E-05 3.97E-05 7.32E-03 7.42E-11 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

TEEN

2.22E-05 : 1.30E-05 : 4.41E-05 : 4.12E-05 : 7.09E-05 : 1.16E-02 : 1.53E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-__+___+-___+

CHILD

4.14E-05 : 1.04E-05 : 1.08E-04 : 7.19E-05 : 1.18E-04 : 2.30E-02 : 2.35E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+

INFANT : 7.83E-05 : 1.03E-05 : 2.18E-04 : 1.76E-04 : 2.05E-04 : 5.60E-02 : 5.68E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

1.59E-05 1.14E-05 3.62E-05 2.78E-05 4.77E-05 8.78E-03 8.91E-12 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---+-______-+____-__+

TEEN

2.67E-05 : 1.55E-05 : 6.61E-05 : 4.94E-05 : 8.51E-05 : 1.39E-02 : 1.84E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-__+___+_+-___+

CHILD

5.01E-05 : 1.26E-05 : 1.62E-04 : 8.61E-05 : 1.42E-04 : 2.77E-02 : 2.82E-11 : O.00E+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-__+_+-___+

INFANT : 9.49E-05 : 1.26E-05 : 3.24E-04 : 2.11E-04 : 2.46E-04 : 6.72E-02 : 6.82E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT

1.83E-06 : 4.09E-06 : 3.09E-06 4.52E-06 : 7.81E-06
9.56E-04 1.48E-05 O.OOE+00

-________+______-___+_________-+-_________+_________-+________-_+________-_+________-_+________-_+

TEEN

2.44E-06 : 1.22E-05 : 4.35E-06 : 6.24E-06 : 1.08E-05 : 1.23E-03 : 2.33E-05 : 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

2.78E-06 : 8.24E-05 : 5.93E-06 : 6.16E-06 : 1.02E-05 : 1.48E-03 : 1.99E-05 : O.OOE+00 :

INFANT : 2.OOE-06 : 7.20E-05 : 4.64E-06 : 5.76E-06 : 6.71E-06 : 1.36E-03 : 1.65E-05 : O.OOE+00 :

+-----------+----------

-+----

+------

+--+-------

+-+-

+

+

0

TABLE 5.

DOSES TO MAXIMUM INDIVIDUAL (HREM),

OCTOBER-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

3 A Nearest Resident AT

.90 MILES NW ANNUAL BETA AIR DOSE = 1.86E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 2.37E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+__________+__________+

_________+__________+_

________+__________+_---________+-

+ ___-_

_ +

PLUME

1.59E-05 : 1.59E-05 : 1.59E-05 : 1.59E-05 : 1.59E-05 : 1.59E-05 : 1.61E-05 : 3.36E-05 :

-+__________+__________+

_________+__________+_

________+__________+_--+

-__+_____+_+-_

_+

GROUND

3.49E-05 : 3.49E-05 : 3.49E-05 : 3.49E-05 : 3.49E-05 : 3.49E-05 : 3.49E-05 : 4.11E-05 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 6.24E-06 1.86E-05 6.67E-05 7.13E-06 1.18E-05 2.23E-03 8.51E-10 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

-____+_+-_

_+

TEEN

9.33E-06 : 2.17E-05 : 1.10E-04 : 1.07E-05 : 1.78E-05 : 2.99E-03 : 1.55E-09 0.00E+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+__-

_ +

CHILD

1.88E-05 : 1.65E-05 : 2.68E-04 : 1.80E-05 : 2.86E-05 : 5.73E-03 : 2.32E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 2.61E-07 1.41E-06 7.61E-07 2.44E-07 3.11E-07 5.95E-05 3.22E-11 O.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+__-

_ +

TEEN

2.05E-07 : 7.76E-07 : 6.40E-07 : 1.96E-07 : 2.54E-07 : 4.31E-05 : 3.05E-11 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+ ___- _

_ +

CHILD

3.12E-07 : 4.07E-07 : 1.21E-06 : 2.54E-07 : 3.23E-07 : 6.50E-05 : 3.57E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

7 ADULT

3.09E-06 2.42E-06 6.57E-06 5.36E-06 9.17E-06 1.69E-03 3.01E-11 0.OOE+00 t-

-+------------------------------------------------------------------

+-

-+--+-

+-+-

+

+

+

TEEN

5.17E-06 : 3.26E-06 : 1.20E-05 : 9.52E-06 : 1.64E-05 : 2.68E-03 : 6.23E-11 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+

-__+-_

_+

CHILD

9.69E-06 : 2.60E-06 : 2.94E-05 : 1.66E-05 : 2.72E-05 : 5.32E-03 : 9.53E-11 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+

+

+__-

_ +

INFANT : 1.83E-05 : 2.58E-06 : 5.90E-05 : 4.06E-05 : 4.74E-05 : 1.29E-02 : 2.31E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

3.74E-06 2.95E-06 1.04E-05 6.42E-06 1.10E-05 2.03E-03 3.62E-12 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

-____+__-

+__-

_ +

TEEN

6.27E-06 : 4.02E-06 : 1.90E-05 : 1.14E-05 : 1.96E-05 : 3.21E-03 : 7.48E-12 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+ ___- _

_ +

CHILD

1.18E-05 : 3.26E-06 : 4.67E-05 : 1.99E-05 : 3.27E-05 : 6.39E-03 : 1.14E-11 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_---+

+

+___- _

_ +

INFANT : 2.24E-05 : 3.26E-06 : 9.25E-05 : 4.87E-05 : 5.68E-05 : 1.55E-02 : 2.77E-11 : 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL:

ADULT

5.12E-07 : 1.30E-06 : 9.OOE-07 : 1.26E-06 2.18E-06 2.66E-04 4.47E-06 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+

-__+-_

_+

TEEN

6.83E-07 : 3.59E-06 : 1.27E-06 : 1.74E-06 : 3.01E-06 : 3.42E-04 : 7.07E-06 : 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+ ___- _

_ +

CHILD

7.77E-07 : 2.32E-05 : 1.73E-06 : 1.71E-06 : 2.83E-06 : 4.13E-04 : 6.03E-06 : 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+

-________+-

+ __- _

_ +

INFANT : 5.60E-07 : 2.03E-05 : 1.35E-06 : 1.60E-06 : 1.87E-06 : 3.79E-04 : 5.06E-06 : 0.OOE+00 :

- - + -

4--

4-.

TABLE 5.

DOSES TO MXnl4UM INDIVIDUAL (NMEM),

OCTOBER-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 2.99E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 3.74E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

_________+-_________+_______-__+________-_+________-_+_________-+_________-+________-_+________-_+

PLUME

2.51E-04 : 2.51E-04 : 2.51E-04 : 2.51E-04
2.51E-04 : 2.51E-04 : 2.54E-04
5.61E-04 :

_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+

GROUND

2.61E-06 : 2.61E-06 : 2.61E-06 : 2.61E-06 : 2.61E-06 : 2.61E-06 : 2.61E-06 : 3.07E-06 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 7.12E-07 2.89E-06 1.22E-05 5.92E-07 9.87E-07 1.86E-04 1.86E-10 0.OOE+00

_________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+________-_+

TEEN 1.10E-06 : 3.46E-06 : 2.03E-05 : 8.90E-07

1.49E-06 : 2.50E-04 : 3.38E-10 0.OOE+00 :

___-_____+-_________+_____--__+_________-+________-_+________-_+________-_+______-_+__-_+

CHILD 2.34E-06 : 2.68E-06 : 4.94E-05 : 1.50E-06 : 2.39E-06 : 4.79E-04 : 5.08E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 2.26E-08 1.28E-07 1.33E-07 1.97E-08 2.60E-08 4.97E-06 7.05E-12 0.OOE+00

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

TEEN

1.79E-08 : 7.24E-08 : 1.12E-07 : 1.59E-08 : 2.12E-08 : 3.60E-06 : 6.68E-12 0.OOE+00 :

_________+_____-____+________-_+_________-+________-_+_________-+__________+_________-+________-_+

CHILD

2.78E-08 : 3.93E-08 : 2.11E-07 : 2.07E-08 : 2.70E-08 : 5.43E-06 : 7.82E-12 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT

2.66E-07 2.59E-07 8.57E-07 4.45E-07 7.63E-07 1.41E-04 6.60E-12 0.OOE+00

_________+______-___+_________-+_________-+_______-__+________-_+________-_+________-_+________-_+

TEEN

4.47E-07 : 3.49E-07 : 1.57E-06 : 7.91E-07 : 1.36E-06 : 2.23E-04 : 1.36E-11 0.OOE+00 :

_________+______-___+_________-+________-_+________-_+________-_+________-_+_________-+________-_+

CHILD

8.47E-07 : 2.79E-07 : 3.86E-06 : 1.38E-06 : 2.26E-06 : 4.43E-04 : 2.09E-11 0.OOE+00 :

_________+-_________+_______-__+_________-+_________-+-_________+_________-+________-_+________-_+

INFANT : 1.60E-06 : 2.78E-07 : 7.60E-06 : 3.38E-06 : 3.94E-06 : 1.08E-03 : 5.05E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

3.30E-07 3.48E-07 1.51E-06 5.34E-07 9.15E-07 1.69E-04 7.92E-13 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+

-________+-

+ __-_

_ +

TEEN

5.56E-07 : 4.74E-07 : 2.76E-06 : 9.48E-07 : 1.63E-06 : 2.68E-04 : 1.64E-12 0.00E+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

+

+__-

_ +

CHILD

1.07E-06 : 3.84E-07 : 6.81E-06 : 1.65E-06 : 2.72E-06 : 5.32E-04 : 2.50E-12 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

-____+__-

+__-

_ +

INFANT : 2.03E-06 : 3.85E-07 : 1.33E-05 : 4.05E-06 : 4.73E-06 : 1.29E-03 : 6.06E-12 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

ImHAL :

ADULT 7.83E-08 7.15E-07 2.47E-07 1.74E-07 2.84E-07 3.37E-05 1.64E-06 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+

-____+____-

+ __- _

_ +

TEEN

1.05E-07 : 1.22E-06 : 3.50E-07 : 2.41E-07 : 3.92E-07 : 4.32E-05 : 2.70E-06 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

-____+__-

+__-

_ +

CHILD

1.22E-07 : 4.61E-06 : 4.79E-07 : 2.37E-07 : 3.68E-07 : 5.18E-05 : 2.36E-06 0.OOE+00 :

________+__________+__________+__________+__________+__________+__________+___--+-______+--+__-__+

INFANT : 8.69E-08 : 3.89E-06 : 3.47E-07 : 2.21E-07 : 2.43E-07 : 4.75E-05 : 2.16E-06 : O.OOE+00 :

+-----------+-----------+----------+-----------+-------- +--

+--+-

+

TABLE 5.

DOSES TO MAXnIUM INDIVIDUAL (MREM),

OCTOBER-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

5 A

Nearest Garden AT 1.90 MILES NNW ANNUAL BETA AIR DOSE = 2.99E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 3.74E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

PLUME

2.51E-04 : 2.51E-04
2.51E-04 : 2.S1E-04 : 2.51E-04 : 2.51E-04
2.54E-04 : 5.61E-04 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

GROUND 1.03E-05 1.03E-05 1.03E-05 : 1.03E-05 : 1.03E-05 : 1.03E-05 : 1.03E-05 : 1.21E-05 :

+

+--+-

VEGET ADULT 2.16E-06 7.52E-06 2.96E-05 2.15E-06 3.56E-06 6.73E-04 4.19E-10 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+_--_____+___+-________+

TEEN

3.27E-06 : 8.91E-06 : 4.89E-05 : 3.23E-06 : 5.37E-06 : 9.04E-04 : 7.61E-10 : O.OOE+00 :

-_______+__________+__________+__________+__________+__________+__________+_--_____+___+-________+

CHILD

6.77E-06 : 6.84E-06 : 1.19E-04 : 5.43E-06 : 8.64E-06 : 1.73E-03 : 1.14E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 8.09E-08 4.46E-07 3.28E-07 7.32E-08 9.41E-08 1.80E-05 1.59E-11 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+_--_________+-________+

TEEN

6.36E-08 : 2.49E-07 : 2.76E-07 : 5.88E-08 : 7.69E-08 : 1.30E-05 : 1.50E-11 : O.OOE+00 :

-________+______-___+_________-+________-_+_________-+-_________+__________+-_________+_________-+

CHILD

9.76E-08 : 1.32E-07 : 5.20E-07 : 7.64E-08 : 9.76E-08 : 1.97E-05 : 1.76E-11 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT

9.41E-07 8.02E-07 2.41E-06 1.60E-06 2.75E-06 5.09E-04 1.48E-11 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

TEEN

1.58E-06 : 1.08E-06 : 4.42E-06 : 2.85E-06 : 4.90E-06 : 8.06E-04 : 3.07E-11 : O.OOE+00 :

CHILD

2.97E-06 : 8.59E-07 : 1.08E-05 : 4.97E-06 : 8.15E-06 : 1.60E-03 : 4.70E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

INFANT : 5.62E-06 : 8.51E-07 : 2.15E-05 : 1.22E-05 : 1.42E-05 : 3.89E-03 : 1.14E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

1.15E-06 1.02E-06 4.03E-06 1.92E-06 3.30E-06 6.11E-04 1.78E-12 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

TEEN

1.93E-06 : 1.39E-06 : 7.40E-06 : 3.41E-06 : 5.88E-06 : 9.67E-04 : 3.68E-12 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

CHILD

3.67E-06 : 1.12E-06 : 1.82E-05 : 5.95E-06 : 9.78E-06 : 1.92E-03 : 5.64E-12 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-+-+-+___-__+

INFANT : 6.96E-06 : 1.12E-06 : 3.57E-05 : 1.46E-05 : 1.70E-05 : 4.67E-03 : 1.36E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 1.90E-07 8.48E-07 4.29E-07 4.40E-07 : 7.41E-07 9.24E-05 2.17E-06 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

TEEN

2.53E-07 : 1.22E-06 : 6.07E-07 : 6.06E-07 : 1.02E-06 : 1.18E-04 : 3.46E-06 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

CHILD

2.88E-07 : 3.17E-06 : 8.29E-07 : 5.98E-07 : 9.62E-07 : 1.41E-04 : 2.97E-06 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

INFANT : 2.07E-07 : 2.58E-06 : 6.21E-07 : 5.58E-07 : 6.35E-07 : 1.30E-04 : 2.52E-06 : O.OOE+00 :

- - - - + - -

+ - - - -

+-

4--

4 4

III

TABLE 6.

DOSES TO MAXIMUM INDIVIDUAL (MEM), JULY-DECEMBER 2003 SPECIAL LOCATION NO.

1 A

Site Boundary AT

.69 MILES NNW ANNUAL BETA AIR DOSE -

4. 60E-02 MILIRADS ANNUAL GAMMA AIR DOSE -

7.04E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN PLUME

4.68E-02 : 4.68E-02 : 4.68E-02 : 4.68E-02 : 4.68E-02 : 4.68E-02 : 4.73E-02 : 8.93E-02

-+__________+__________+

_________+__________+_

________+__________+_---__+_+____- + ___-_

_ +

GROUND

6.96E-04 : 6.96E-04 : 6.96E-04 : 6.96E-04 : 6.96E-04 : 6.96E-04 : 6.96E-04 : 8.08E-04

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 6.43E-05 2.67E-04 1.06E-03 5.37E-0S 8.77E-05 1.62E-02 1.39E-08 O.OOE+00

_________+-_________+_______-__+________-_+_________-+_________-+________-_+________-_+________-_+

TEEN

9.86E-05 : 3.16E-04 : 1.76E-03 : 7.94E-05 : 1.30E-04 : 2.16E-02 : 2.52E-08 : O.OOE+00

_________+-_________+________-_+_________-+________-_+________-_+________-_+________-_+________-_+

CHILD

2.10E-04
2.42E-04
4.30E-03 : 1.33E-04 : 2.08E-04
4.13E-02
3.77E-08
O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 2.58E-06 1.63E-05 1.14E-05 1.98E-06 2.22E-06 4.24E-04 5.25E-10 O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+___- _

_ +

TEEN

2.04E-06 : 9.06E-06 : 9.62E-06 : 1.59E-06 : 1.81E-06 : 3.07E-04 : 4.97E-10 : O.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_---________- +____- _

_ +

CHILD

3.17E-06 : 4.80E-06 : 1.82E-05 : 2.04E-06 : 2.30E-06 : 4.64E-04 : 5.81E-10 :.OOE+0O

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT

2.40E-05 2.66E-05 7.62E-05 4.18E-05 7.17E-05 1.26E-02 4.90E-10 :.OOE+OO w ________ + __________+__________+__________+__________+__________+__________+--+

-_______++-_____

_ +

4 TEEN

4.05E-05 : 3.63E-05 : 1.40E-04 : 7.43E-05 : 1.28E-04
2.OOE-02 : 1.O1E-09 : O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+

-________+-

+__-

_ +

CHILD

7.74E-05 : 2.96E-05 : 3.43E-04 : 1.30E-04 : 2.13E-04 : 4.OOE-02 : 1.55E-09 : O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

-__+

_+

INFANT : 1.47E-04 : 2.96E-05 : 6.77E-04 : 3.18E-04 : 3.71E-04

9.73E-02 : 3.75E-09 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATHILK :

ADULT

2.96E-05 3.43E-05 1.33E-04 5.01E-05 8.60E-05 1.51E-02 5.89E-1l
O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+

-__+

_+

TEEN

5.01E-05 : 4.73E-05 : 2.45E-04 : 8.89E-05 : 1.53E-04
2.40E-02 : 1.22E-10 : O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_---________+- +___- _

_ +

CHILD

9.70E-05 : 3.91E-05 : 6.02E-04 : 1.55E-04 : 2.56E-04 : 4.81E-02 : 1.86E-10 :.OOE+0O

_________+______

___+__

+_____

____+

__+___

___+_---+

+

+

+___- _

_ +

INFANT

1.84E-04 : 3.94E-05 : 1.17E-03 : 3.81E-04 : 4.45E-04 : 1.17E-01 : 4.51E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 1.11E-05 2.20E-05 1.63E-05 : 2.67E-05 : 3.72E-05 3.08E-03 : 6.49E-05 O.OOE+O0 TEEN

1.51E-05 : 7.31E-05 : 2.29E-05 : 3.68E-05 : 5.16E-05 : 4.05E-03 : 1.05E-04
O.OOE+00

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+___- _

_ +

CHILD

1.83E-05
5.21E-04
3.12E-05 : 3.63E-05 : 4.85E-05 : 5.08E-03 : 9.04E-05 : O.OOE+O0

_________+ ______

___+__

+_____

____+

__+___

___+_--+

+___- _

_ +

INFANT : 1.31E-05

4.66E-04
2.47E-05 : 3.40E-05
3.21E-05 : 4.68E-03 : 8.05E-05
0.OOE+OO

_________+ ______

___+__

+_____

____+

__+___

___+_---________- +____- _

_ +

TABLE 6.

DOSES TO MAXIMUM INDIVIDUAL (MRM, JULY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

2 A

Site Boundary AT

.67 MILES N

ANNUAL BETA AIR DOSE = 5.52E-02 MILLRADS ANNUAL GA1MMA AIR DOSE = 8.44E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+_____-____+________-_+_________-+__________+__________+__________+__________+_________-+

PLUM 5.62E-02 : 5.62E-02

5.62E-02 : 5.62E-02 : 5.62E-02 : 5.62E-02 : 5.68E-02 : 1.07E-01 :

-________+___

__+

_+_

+__

__+

_+_--+-

+

+

+

+

+

+__-

_+

GROUND 9.32E-04 : 9.32E-04 : 9.32E-04 : 9.32E-04 : 9.32E-04 : 9.32E-04 : 9.32E-04 : 1.08E-03 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 8.62E-05 3.64E-04 1.47E-03 7.03E-05 1.15E-04 2.12E-02 1.92E-O8 O.OOE+00

_________+__________+__________+__________+__________+__________+__________--_________++-________+

TEEN

1.33E-04 : 4.31E-04 : 2.42E-03 : 1.04E-04 : 1.70E-04 : 2.83E-02 : 3.49E-08 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

CHILD

2.84E-04 : 3.31E-04 : 5.92E-03 : 1.74E-04 : 2.72E-04 : 5.41E-02 : 5.23E-08 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 3.39E-06 2.15E-05 1.57E-05 2.59E-06 2.91E-06 5.55E-04 7.27E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

TEEN

2.68E-06 : 1.19E-05 : 1.32E-05 : 2.07E-06 : 2.37E-06 : 4.02E-04 : 6.89E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+

CHILD

4.18E-06 : 6.34E-06 : 2.50E-05 : 2.66E-06 : 3.02E-06 : 6.07E-04 : 8.06E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILX ADULT

3.15E-05 3.55E-05 1.03E-04 5.48E-05 9.38E-05 1.65E-02 6.80E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

TEEN

5.31E-05 : 4.83E-05 : 1.89E-04 : 9.73E-05 : 1.67E-04 : 2.62E-02 : 1.41E-09 : O.OOE+00 :

-________ + __________+__________+__________+__________+__________+__________+-

________+___- __

_ +

CHILD

1.02E-04 : 3.94E-05 : 4.65E-04 : 1.70E-04 : 2.79E-04 : 5.24E-02 : 2.15E-09 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-______+__-+__-__+

INFANT : 1.93E-04 : 3.94E-05 : 9.15E-04 : 4.16E-04 : 4.85E-04 : 1.27E-01 : 5.21E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILX :

ADULT

3.90E-05 4.60E-05 1.81E-04 6.55E-05 1.13E-04 1.98E-02 8.16E-11 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-____+____-+__-__+

TEEN

6.59E-05 : 6.34E-05 : 3.33E-04 : 1.16E-04 : 2.01E-04 : 3.14E-02 : 1.69E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-____+_+___+-___+

CHILD

1.28E-04 : 5.24E-05 : 8.20E-04 : 2.03E-04 : 3.34E-04 : 6.29E-02 : 2.58E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-____+____-+__-__+

INFANT : 2.43E-04 : 5.28E-05 : 1.60E-03 : 4.98E-04 : 5.82E-04 : 1.53E-01 : 6.25E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHA:

ADULT

1.30E-05 2.56E-05 : 1.91E-05 3.12E-05 : 4.36E-05 3.62E-03
  • 7.47E-05 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-______+__-+__-__+

TEEN

1.77E-05 : 8.47E-05 : 2.68E-05 : 4.31E-05 : 6.04E-05 : 4.75E-03 : 1.21E-04 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-____+__-+__-__+

CHILD

2.14E-05 : 6.02E-04 : 3.66E-05 : 4.26E-05 : 5.68E-05 : 5.95E-03 : 1.04E-04 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

INFANT : 1.54E-05 : 5.38E-04 : 2.89E-05 : 3.99E-05 : 3.76E-05 : 5.49E-03 : 9.28E-05 : O.OOE+00

- - - - - + - - - -

- - - + - - -

- - + -

4--

OiZj

TABLE 6.

DOSES TO MXXIMUM INDIVIDUAL (MREM, JULY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

3 A Nearest Resident AT

.90 MILES NW ANNUAL BETA AIR DOSE -

1.41E-02 MILLRADS ANNUAL GAMMA AIR DOSE - 2.09E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+-_________+_________-+________-_+________-_+________-_+________-_+________-_+

PLUME

1.39E-02 : 1.39E-02
1.39E-02 : 1.39E-02 : 1.39E-02
1.39E-02 : 1.41E-02 : 2.72E-02 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-__+_+-___+

GROUND

4.30E-04 : 4.30E-04 : 4.30E-04 : 4.30E-04 : 4.30E-04 : 4.30E-04 : 4.30E-04 : 4.95E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 4.04E-05 2.02E-04 9.04E-04 2.27E-05 3.72E-05 6.88E-03 1.26E-08 O.OOE+00

-+---------------------------+-

-+

-+-

+---

TEEN

6.36E-05 : 2.43E-04 : 1.50E-03 : 3.36E-05 : 5.53E-05 : 9.20E-03 : 2.29E-08 : O.OOE+00 :

+

+--------------------------+-

-+

-+-

+--

CHILD

1.42E-04 : 1.89E-04 : 3.66E-03 : 5.62E-05 : 8.86E-05 : 1.76E-02 : 3.43E-08 : 0.0oE+00 :

+

-+---------------------------+-

-+

-+-

MEAT ADULT 1.17E-06 7.73E-06 9.51E-06 8.12E-07 9.47E-07 1.81E-04 4.77E-10 0.OOE+00

_________+___

______+______---

+

+-

_________+__________+__________+__________+_____---+___+__--_

+

TEEN

9.34E-07 : 4.40E-06 : 8.01E-06 : 6.51E-07 : 7.74E-07 : 1.31E-04 : 4.52E-10 : 0.0oE+00 :

_________+___

______+______---__+- _________+__________+__________+__________+_____--+

-___+__--_

+

CHILD

1.49E-06 : 2.41E-06 : 1.51E-05 : 8.38E-07 : 9.83E-07 : 1.98E-04 : 5.28E-10 0.OOE+00 :

_________+___

______+______---__+- _________+__________+__________+__________+_____--+

-_+_+__--_

+

COW MILK :

ADULT

1.08E-05 1.50E-05 5.33E-05 1.76E-05 3.02E-05 5.33E-03 4.46E-10 0.OOE+00

+

+

+-

-+

-+-

+--

CN TEEN

1.82E-05 : 2.05E-05 : 9.80E-05 : 3.13E-05 : 5.39E-05 : 8.47E-03 : 9.22E-10 0.OOE+00 :

+-

+

+ -

+ -+

+---

CHILD

3.55E-05 : 1.66E-05 : 2.41E-04 : 5.47E-05 : 8.97E-05 : 1.70E-02 : 1.41E-09 0.OOE+00 :

+

+--------------------------+-

-+

-+-

+--

INFANT : 6.72E-05 : 1.67E-05 : 4.69E-04 : 1.34E-04 : 1.56E-04 : 4.12E-02 : 3.41E-09 : 0.00E+00 :


+

+--------------------------+-

-+

-+-

+--

GOATMILK :

ADULT

1.38E-05 2.14E-05 1.OOE-04 2.11E-05 3.62E-05 6.40E-03 5.35E-11 0.OOE+00

_________+___

______+______---

+

+-_________+__________+__________+__________+_____--+

-___+__--_

+

TEEN

2.35E-05 : 2.95E-05 : 1.84E-04 : 3.75E-05 : 6.46E-05 : 1.02E-02 : 1.11E-10 0.OOE+00 :

_________+_________+______--+-+-+-_________+__________+__________+__________+____--+-+___+__--__+

CHILD

4.67E-05 : 2.41E-05 : 4.54E-04 : 6.54E-05 : 1.08E-04 : 2.03E-02 : 1.69E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+--+_________--

+ -

+

INFANT : 8.87E-05 : 2.44E-05 : 8.75E-04 : 1.60E-04 : 1.87E-04 : 4.94E-02 : 4.10E-10 : O.OOE+00 :

_________+_________+______--+-+-+-_________+__________+__________+__________+____--+-+___+__--__+

nlHAL ADULT 1.05E-05 1.66E-05 1.25E-05 2.14E-05 2.08E-05 8.04E-04 4.74E-05 0.OOE+00

+

-+---------------------------+-

-+

-+-

+--

TEEN

1.44E-05 : 6.71E-05 : 1.77E-05 : 2.96E-05 : 2.88E-05 : 1.06E-03 : 7.94E-05 : O.OOE+00 :

+--------------------------+-

-+

-+-

+---

CHILD

1.78E-05 : 5.19E-04 : 2.40E-05 : 2.91E-05 : 2.70E-05 : 1.32E-03 : 6.99E-05 0.OOE+00 :

+

-+---------------------------+-

-+

-+-

+---

INFANT 1.27E-05 : 4.73E-04 : 1.90E-05 : 2.71E-05 : 1.79E-05 : 1.22E-03 : 6.80E-05 : 0.OOE+00 :

+

TABLE 6.

DOSES TO MAXIMUM INDIVIDUAL (MBM, JULY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 2.69E-03 MILLRADS ANNUAL GAM4M AIR DOSE = 3.11E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+_____-____+________-_+_________-+_________-+_________-+__________+__________+_________-+

PLUME

2.07E-03 : 2.07E-03 : 2.07E-03 : 2.07E-03
2.07E-03
2.07E-03 : 2.10E-03 : 4.63E-03 :

-________+______-___+_________-+________-_+________-_+_________-+_________-+__________+_________-+

GROUND

3.14E-05
3.14E-05 : 3.14E-05 : 3.14E-05 : 3.14E-05
3.14E-05 : 3.14E-05 : 3.62E-05 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 2.98E-06 1.59E-05 7.34E-05 1.35E-06 2.23E-06 4.13E-04 1.04E-09 O.OOE+00

-________+__________+__________+_____--___+-_________+__________+__________+_____--___-+-________+

TEEN

4.73E-06 : 1.92E-05 : 1.22E-04 : 2.01E-06 : 3.32E-06 : 5.53E-04 : 1.89E-09 : O.OOE+00 :

-________+__________+__________+_____--+-___+-_________+__________+__________+___--+--___+-______+

CHILD : 1.07E-05 : 1.50E-05 : 2.97E-04 : 3.37E-06 : 5.32E-06 : 1.06E-03 : 2.83E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 7.38E-08 5.00E-07 7.67E-07 4.76E-08 5.70E-08 1.09E-05 3.93E-11 O.OOE+00

-________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

TEEN

5.90E-08 : 2.88E-07 : 6.46E-07 : 3.82E-08 : 4.66E-08 : 7.89E-06 : 3.73E-11 : O.OOE+00 :

-________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+________-_+

CHILD

9.55E-08 : 1.61E-07 : 1.22E-06 : 4.92E-08 : 5.92E-08
1.19E-05 : 4.36E-11 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT : 6.69E-07 1.05E-06 4.08E-06 1.05E-06 1.79E-06 3.19E-04 3.68E-11 O.OOE+00

-_________+__________+__________+__________+__________+__________+__________+--+

-_____+_++-_____

_ +

TEEN 1.14E-06 : 1.44E-06 : 7.50E-06 : 1.86E-06 : 3.20E-06 : 5.07E-04 : 7.61E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

CHILD

2.23E-06 : 1.16E-06 : 1.85E-05 : 3.24E-06 : 5.32E-06 : 1.01E-03 : 1.16E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+

INFANT : 4.23E-06 : 1.17E-06 : 3.58E-05 : 7.94E-06 : 9.26E-06 : 2.46E-03 : 2.82E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

8.78E-07 1.57E-06 7.83E-06 1.25E-06 2.15E-06 3.83E-04 4.41E-12 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-+-+__-__+

TEEN

1.50E-06 : 2.16E-06 : 1.44E-05 : 2.22E-06 : 3.84E-06 : 6.08E-04 : 9.13E-12 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-+-+-+-+-+___-__+

CHILD

3.03E-06 : 1.76E-06 : 3.56E-05 : 3.88E-06 : 6.38E-06 : 1.21E-03 : 1.40E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

INFANT : 5.75E-06 : 1.77E-06 : 6.84E-05 : 9.51E-06 : 1.11E-05 : 2.95E-03 : 3.38E-11 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 7.92E-06 1.15E-05 8.81E-06 1.53E-05 1.24E-05 1.15E-04 3.24E-05 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---________+-+___-__+

TEEN

1.09E-05 : 4.99E-05 : 1.24E-05 : 2.11E-05 : 1.71E-05 : 1.51E-04 : 5.52E-05 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+

CHILD

1.35E-05 : 3.95E-04 : 1.69E-05 : 2.07E-05 : 1.60E-05 : 1.87E-04 : 4.90E-05 : O.OOE+00 :

INFANT : 9.71E-06 : 3.62E-04 : 1.33E-05 : 1.93E-05 : 1.06E-05 : 1.72E-04 : 4.93E-05 : O.OOE+00 :

-________+______-___+_________-+_________-+________-_+________-_+_______-__+________-_+________-_+

TABLE 6.

DOSES TO MAXIMUM INDIVIDUAL (CUM-0, JULY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

5 A Nearest Garden AT 1.90 MILES NNW ANNUAL BETA AIR DOSE -

7.06E-03 MILLRADS ANNUAL GAMMA AIR DOSE -

1.03E-02 MILLJADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-+__________+__________+

_________+__________+_

________+__________+_---________+-

+ ___- _

_ +

PLUME

6.84E-03 : 6.84E-03 : 6.84E-03 : 6.84E-03 : 6.84E-03 : 6.84E-03
6.91E-03 : 1.36E-02 :

-+__________+__________+

_________+__________+_

________+__________+_---+

+

+

+___- _

_ +

GROUND

9.73E-05 : 9.73E-05 : 9.73E-05 : 9.73E-05 : 9.73E-05 : 9.73E-05
9.73E-05
1.12E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 9.16E-06 4.62E-05 2.08E-04 5.03E-06 8.26E-06 1.53E-03 2.90E-09 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_---+

+

+

+___- _

_ +

TEEN

1.44E-05 : 5.55E-05 : 3.44E-04 : 7.46E-06 : 1.23E-05 : 2.04E-03 : 5.26E-09 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_---________- + ____- _

_ +

CHILD

3.23E-05 : 4.33E-05 : 8.40E-04 : 1.25E-05 : 1.97E-05 : 3.91E-03 : 7.89E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 2.62E-07 1.73E-06 2.18E-06 1.80E-07 2.10E-07 4.02E-05 1.10E-10 O.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_---________+-

+ ___- _

_ +

TEEN

2.08E-07 : 9.85E-07 : 1.84E-06 : 1.44E-07 : 1.72E-07 : 2.91E-05 : 1.04E-10 : O.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+ ___- _

_ +

CHILD

3.32E-07 : 5.41E-07 : 3.47E-06 : 1.86E-07 : 2.18E-07 : 4.39E-05 : 1.22E-10 0.00E+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT

2.40E-06 3.39E-06 1.22E-05 3.91E-06 6.69E-06 1.18E-03 1.03E-10 0.00E+00 00 TEEN
4.06E-06 : 4.62E-06 : 2.23E-05 : 6.94E-06 : 1.19E-05 : 1.88E-03 : 2.12E-10 0.OOE+00 :

CHILD

7.91E-06 : 3.75E-06 : 5.50E-05 : 1.21E-05 : 1.99E-05 : 3.76E-03 : 3.25E-10 0.OOE+00 :

-+__________+__________+

_________+__________+_

________+__________+_--+

+ ___- _

_ +

INFANT : 1.50E-05 : 3.76E-06 : 1.07E-04 : 2.97E-05 : 3.46E-05 : 9.14E-03 : 7.85E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

3.08E-06 4.86E-06 2.28E-05 4.68E-06 8.03E-06 1.42E-03 1.23E-11 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_---________- +____- _

_ +

TEEN

5.25E-06 : 6.68E-06 : 4.20E-05 : 8.31E-06 : 1.43E-05 : 2.26E-03 : 2.55E-11 0.OOE+00 :

_________+ ______

___+__

+_____

____+

__+___

___+_--+-

+

+

-____+_+

_+

CHILD

1.04E-05 : 5.47E-06 : 1.04E-04 : 1.45E-05 : 2.39E-05 : 4.51E-03 : 3.89E-11 : O.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+

-________+-

+__-

_ +

INFANT : 1.98E-05 : 5.52E-06 : 2.OOE-04 : 3.56E-05 : 4.16E-05 : 1.10E-02 : 9.42E-11 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 8.38E-06 : 1.26E-05 9.63E-06 : 1.66E-05 1.46E-05 : 3.45E-04 : 3.58E-05 : O.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+

+___- _

_ +

TEEN

1.15E-05 : 5.33E-05 : 1.35E-05 : 2.29E-05 : 2.02E-05 : 4.53E-04 : 6.06E-05 : 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+

+__-

_ +

CHILD

1.43E-05 : 4.18E-04 : 1.84E-05 : 2.25E-05 : 1.90E-05 : 5.66E-04 : 5.36E-05 : 0.OOE+00 :

_________+______

___+__

+_____

____+

__+___

___+_--+-

+

+

+__-

_ +

INFANT : 1.02E-05 : 3.82E-04 : 1.46E-05 : 2.10E-05 : 1.25E-05 : 5.22E-04 : 5.32E-05 : 0.OOE+00 :

+-----

+


+------------+-

+

+

+

+

+

+-+

TABLE 7.

DOSES TO MAXIMUM INDIVIDUAL (MREM),

JANUARY-DECEMBER 2003 SPECIAL LOCATION NO.

1 A

Site Boundary AT

.69 MILES NNW ANNUAL BETA AIR DOSE - 1.28E-01 MILLRADS ANNUAL GAMMA AIR DOSE = 1.95E-01 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

_______-_+-_________+_____-__-_+_________-+_________-+_________-+_________-+________-_+________-_+

PLUM

1.30E-01 : 1.30E-01 : 1.30E-01 : 1.30E-01 : 1.30E-01 : 1.30E-01 : 1.31E-01 : 2.48E-01

________-+-_________+_____-____+________-_+_________-+_________-+__________+__________+_________-+

GROUND

4.40E-03 : 4.40E-03 : 4.40E-03 : 4.40E-03 : 4.40E-03 : 4.40E-03 : 4.40E-03 : 5.17E-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.37E-04 8.12E-04 1.24E-03 1.10E-04 1.22E-04 2.19E-02 2.02E-08 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

-__+___+-_

_+

TEEN

2.12E-04 : 8.99E-04 : 2.06E-03 : 1.65E-04 : 1.82E-04 : 2.94E-02 : 3.59E-08 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+__-_

_ +

CHILD

4.38E-04 : 6.27E-04 : 5.02E-03 : 2.67E-04 : 2.90E-04 : 5.62E-02 : 5.30E-08 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.79E-05 1.44E-04 1.34E-05 9.43E-06 3.09E-06 5.79E-04 7.45E-10 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+-

+

-__+_+___+-_

_+

TEEN

1.41E-05 : 7.80E-05 : 1.13E-05 : 7.38E-06 : 2.52E-06 : 4.20E-04 : 6.87E-10 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_---________+- + ___-_

_ +

CHILD

2.20E-05 : 3.96E-05 : 2.13E-05 : 8.97E-06 : 3.20E-06 : 6.34E-04 : 7.93E-10 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK ADULT

3.50E-05 5.99E-05 9.33E-05 5.67E-05 9.43E-05 1.69E-02 1.36E-09 0.OOE+00

_________+ __________+__________+__________+__________+__________+__________+--+

-________+-_____

_ +

TEEN

5.91E-05 : 7.61E-05 : 1.71E-04 : 1.01E-04 : 1.68E-04 : 2.68E-02 : 2.65E-09 : O.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_--+

-________+-

+__-

_ +

CHILD

1.13E-04 : 5.67E-05 : 4.19E-04 : 1.75E-04 : 2.80E-04 : 5.35E-02 : 3.92E-09 0.OOE+00

_________+ ______

___+__

+_____

____+

__+___

___+_---________+- +___-_

_ +

INFANT : 2.11E-04 : 5.39E-05 : 8.29E-04 : 4.26E-04 : 4.87E-04 : 1.30E-01 : 8.46E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILR :::::::

ADULT

3.95E-05 4.45E-05 1.61E-04 6.60E-05 1.13E-04 2.02E-02 1.63E-10 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

-______+-

+ __-_

_ +

TEEN

6.67E-05 : 6.05E-05 : 2.95E-04 : 1.17E-04 : 2.02E-04 : 3.21E-02 : 3.18E-10 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+__-_

_ +

CHILD

1.28E-04 : 4.91E-05 : 7.26E-04 : 2.05E-04 : 3.36E-04 : 6.42E-02 : 4.70E-10 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

+

+

-__+-_

_+

INFANT : 2.43E-04 : 4.90E-05 : 1.42E-03 : 5.01E-04 : 5.84E-04 : 1.56E-01 : 1.02E-09 0.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 1.15E-05 3.61E-05 1.62E-05 2.69E-05 3.71E-05 3.26E-03 3.18E-04 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_---+

+

+

+___-_

_ +

TEEN

1.57E-05 : 9.12E-05 : 2.29E-05 : 3.71E-05 : 5.14E-05 : 4.25E-03 : 4.75E-04 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

-____+_+-_

_+

CHILD

1.88E-05 : 5.54E-04 : 3.11E-05 : 3.64E-05 : 4.83E-05 : 5.27E-03 : 3.91E-04 0.OOE+00

-+__________+__________+

_________+__________+_

________+__________+_--+-

+

+

-____+_+-_

_+

INFANT : 1.33E-05 : 4.88E-04 : 2.45E-05 : 3.37E-05 : 3.19E-05 : 4.85E-03 : 2.74E-04 : O.OOE+00

+-----

+-

+----+-

+

+

+-+

TABLE 7.

DOSES TO MAXIMUM INDIVIDUAL (MREM),

JANUARY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

2 A

Site Boundary AT

.67 MILES N

ANNUAL BETA AIR DOSE = 1.56E-01 MILLRADS ANNUAL GAMM-A AIR DOSE - 2.37E-01 MILLRADS

  • TI 0-PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-+-+-__+-___+

PLUME

1.58E-01 : 1.58E-01 : 1.58E-01 : 1.58E-01 : 1.58E-01 1.58E-01 : 1.59E-01 : 3.01E-01

-_______+__________+__________+__________+__________+__________+__________+___--_______--+-+__-__+

GROUND

5.91E-03 : 5.91E-03 : 5.91E-03 : 5.91E-03 : 5.91E-03 : 5.91E-03 : 5.91E-03 : 6.94E-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.88E-04 1.11E-03 1.81E-03 1.48E-04 1.65E-04 2.97E-02 2.89E-08 O.OOE+0O

-_______+__________+__________+__________+__________+__________+__________+___--+-+-_____--+__-__+

TEEN

2.91E-04 : 1.23E-03 : 2.99E-03 : 2.22E-04 : 2.46E-04 : 3.98E-02 : 5.14E-08 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-____-+__-__+

CHILD

6.03E-04 : 8.64E-04 : 7.31E-03 : 3.59E-04 : 3.93E-04 : 7.61E-02 : 7.61E-08 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 2.39E-05 1.93E-04 1.94E-05 1.26E-05 4.19E-06 7.8SE-04 1.07E-09 O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-_____--+__-__+

TEEN

1.89E-05 : 1.04E-04 : 1.64E-05 : 9.87E-06 : 3.42E-06 : 5.68E-04 : 9.87E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

2.94E-05 : 5.30E-05 : 3.08E-05 : 1.20E-05 : 4.33E-06 : 8.S8E-04 : 1.14E-09 : O.OOE+00 COW MILK :

ADULT

4.75E-05 8.15E-05 1.32E-04 7.67E-05 1.28E-04 2.28E-02 1.88E-09 O.OOE+00 TEEN
8.02E-05 : 1.04E-04 : 2.42E-04 : 1.36E-04 : 2.28E-04 : 3.63E-02 : 3.67E-09 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-__+____--+__-__+

CHILD

1.54E-04 : 7.74E-05 : 5.94E-04 : 2.37E-04 : 3.79E-04 : 7.24E-02 : 5.44E-09 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-____-+__-__+

INFANT : 2.87E-04 : 7.37E-05 : 1.17E-03 : 5.77E-04 : 6.59E-04 : 1.76E-01 : 1.18E-08 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATMILK :

ADULT

5.38E-05 6.21E-05 2.30E-04 8.94E-05 1.53E-04 2.74E-02 2.26E-10 O.OOE+00 TEEN
9.09E-05 : 8.44E-05 : 4.21E-04 : 1.59E-04 : 2.73E-04 : 4.35E-02 : 4.41E-10 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-+-+--+__-__+

CHILD

1.75E-04 : 6.84E-05 : 1.04E-03 : 2.77E-04 : 4.54E-04 : 8.69E-02 : 6.53E-10 : O.OOE+00

-_______+__________+__________+__________+__________+__________+__________+___--+-+-+-+-+--+__-__+

INFANT : 3.32E-04 : 6.84E-OS : 2.02E-03 : 6.78E-04 : 7.91E-04 : 2.11E-01 : 1.42E-09 : O.OOE+00 INHA ADULT 1.40E-05 : 4.45E-05 : 1.97E-05 : 3.26E-0S 4.53E-05 4.00E-03 3.97E-04 O.OOE+00 TEEN

1.89E-05 : 1.12E-04 : 2.77E-05 : 4.49E-05 : 6.27E-05 : 5.23E-03 : 5.92E-04 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

2.26E-05 : 6.74E-04 : 3.78E-05 : 4.41E-05 : 5.89E-05 : 6.48E-03 : 4.86E-04 : O.OOE+00 INFANT : 1.60E-05 : 5.93E-04 : 2.97E-05 : 4.08E-05 : 3.89E-05 : 5.96E-03 : 3.40E-04 : O.OOE+00

-________+______-___+________-_+_________-+________-_+_______-__+________-_+________-_+________-_+

TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (REM), JANUARY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

3 A Nearest Resident AT

.90 MILES NW ANNUAL BETA AIR DOSE -

1.91E-02 MILLRADS ANNUAL GAMM4A AIR DOSE -

1.77E-02 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

_______-_+-_________+_____-____+_________-+________-_+________-_+________-_+________-_+________-_+

PLUME

1.17E-02
1.17E-02 : 1.17E-02 : 1.17E-02 : 1.17E-02 : 1.17E-02 : 1.19E-02 : 2.66E-02 :

-________+__________+______--+

__+

-_________+__________+__________+__________--+-

+

+

-__+-_____

+

GROUND

1.81E-03
1.81E-03 : 1.81E-03 : 1.81E-03 : 1.81E-03 : 1.81E-03 : 1.81E-03
2.12E-03 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 7.25E-05 4.26E-04 1.08E-03 4.68E-05 5.53E-05 1.OOE-02 1.56E-08 O.OOE+00

-________+__________+______--+

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

TEEN

1.14E-04 : 4.86E-04 : 1.79E-03 : 7.03E-05
8.27E-05
1.34E-02 : 2.81E-08 0.OOE+00 :

_________+-_________+________-_+_________-+________-_+________-_+________-_+________-_+________-_+

CHILD

2.44E-04 : 3.52E-04 : 4.37E-03 : 1.14E-04 : 1.32E-04 : 2.58E-02 : 4.18E-08 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 6.99E-06 5.61E-05 1.14E-05 3.69E-06 1.42E-06 2.66E-04 5.84E-10 0.OOE+00

-+_______

__+____

_____+_

+______--+-

+

-__+__________+___

+-

_ + -___ __

__ +

TEEN

5.54E-06 : 3.04E-05 : 9.57E-06 : 2.89E-06 : 1.16E-06 : 1.93E-04 : 5.47E-10 0.OOE+00 :

_________+______-___+_________-+_________-+________-_+________-_+_________-+________-_+________-_+

CHILD

8.64E-06 : 1.56E-05 : 1.81E-05 : 3.53E-06 : 1.46E-06 : 2.91E-04 : 6.35E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT

1.64E-05 2.90E-05 6.62E-05 2.55E-05 4.26E-05 7.69E-03 7.94E-10 O.OOE+00

_________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-____

_+

TEEN

2.77E-05 : 3.75E-05 : 1.22E-04 : 4.52E-05 : 7.60E-05 : 1.22E-02 : 1.58E-09 0.OOE+00 :

_________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

CHILD

5.35E-05 : 2.84E-05 : 2.99E-04 : 7.87E-05 : 1.26E-04 : 2.43E-02 : 2.37E-09 : O.OOE+00 :

_________+______-___+_________-+_________-+_________-+________-_+________-_+________-_+________-_+

INFANT : 1.OOE-04 : 2.74E-05 : 5.84E-04 : 1.92E-04 : 2.20E-04 : 5.91E-02 : 5.35E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOATHILK :

ADULT

1.94E-05 2.77E-05 1.22E-04 2.98E-05 5.11E-05 9.23E-03 9.53E-11 O.OOE+00

_________+__________+__________+_____--___+-_________+__________+__________+_____--+-___+-_______+

TEEN

3.29E-0S : 3.77E-05 : 2.25E-04 : 5.30E-05 : 9.12E-05 : 1.46E-02 : 1.90E-10 0.OOE+00 :

_________+__________+______-

__+

-_________+__________+__________+__________+----___

+_- ______

_ +

CHILD

6.46E-05 : 3.05E-05 : 5.56E-04 : 9.25E-05 : 1.52E-04 : 2.92E-02 : 2.84E-10 0.OOE+00 :

_________+__________+______--+ -

__+

-_________+__________+__________+__________--+-

+

+

-__+-_____

+

INFANT : 1.22E-04 : 3.06E-05 : 1.07E-03 : 2.26E-04 : 2.64E-04 : 7.09E-02 : 6.42E-10 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHLf ADULT 1.05E-05 1.95E-05 1.26E-05 2.13E-05 2.07E-05 8.78E-04 1.13E-04 0.OOE+00

_________+-_________+_________-+_________-+________-_+_________-+________-_+________-_+________-_+

TEEN

1.44E-05 : 6.43E-05 : 1.77E-05 : 2.94E-05 : 2.86E-05 : 1.14E-03 : 1.74E-04 0.OOE+00 :

_________+_______-__+_________-+_________-+_________-+________-_+________-_+_________-+________-_+

CHILD

1.77E-05 : 4.60E-04 : 2.41E-05 : 2.88E-05 : 2.69E-05 : 1.41E-03 : 1.46E-04 0.OOE+00 :

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

INFANT : 1.27E-05 : 4.19E-04 : 1.90E-05 : 2.68E-05 : 1.77E-05 : 1.30E-03 : 1.15E-04 : O.OOE+00 :

+-

+-----------+

+--------

+

+-+-+

ITJ

.6

TABLE 7.

DOSES TO MAXIMUM INDIVIDUAL (MRM

, JANUARY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

4 A

Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 6.85E-03 MILLRADS ANNUAL GAHMM AIR DOSE = 6.97E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+__________+__________+__________+__________+__________+__________+_---__+______-+___-__+

PLUME

4.65E-03
4.65E-03
4.65E-03 : 4.65E-03 : 4.65E-03 : 4.65E-03 : 4.72E-03 : 1.11E-02 :

-________+__________+__________+__________+__________+__________+__________+_---________+-+___-__+

GROUND

1.04E-04
1.04E-04 : 1.04E-04 : 1.04E-04 : 1.04E-04
1.04E-04 : 1.04E-04 : 1.22E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 4.90E-06 2.87E-05 8.80E-05 2.77E-06 3.43E-06 6.25E-04 1.23E-09 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+

TEEN 7.73E-06 : 3.32E-05 : 1.46E-04 : 4.16E-06 : 5.13E-06 : 8.38E-04

2.22E-09 : 0.00E+00 :

-________+

__+

_+_

+__

+__

__+

_+--+______+---

CHILD 1.69E-05 : 2.45E-05 : 3.56E-04 : 6.79E-06 : 8.21E-06 : 1.61E-03 : 3.32E-09 0.00E+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 3.83E-07 3.06E-06 9.20E-07 2.03E-07 8.81E-08 1.66E-05 4.63E-11 O.OOE+00

-________+__________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+

TEEN

3.04E-07 : 1.67E-06 : 7.75E-07 : 1.59E-07 : 7.19E-08 : 1.20E-05 : 4.35E-11 : O.00E+00 :

-________+__________+_______-__+_________-+__________+__________+__________+____--+-+-+-+_-______+

CHILD

4.77E-07 : 8.59E-07 : 1.46E-06 : 1.95E-07 : 9.12E-08 : 1.81E-05 : 5.06E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT

1.03E-06 1.87E-06 5.09E-06 1.58E-06 2.64E-06 4.79E-04 5.64E-11 0.OOE+00

-________+______-___+__________+_________-+________-_+_________-+________-_+_________-+________-_+

TEEN

1.75E-06 : 2.44E-06 : 9.35E-06 : 2.80E-06 : 4.72E-06 : 7.59E-04 : 1.13E-10 0.OOE+00 :

-________+______-___+________-_+________-_+_________-+_________-+-_________+__________+_________-+

CHILD 3.41E-06 : 1.88E-06 : 2.30E-05 : 4.87E-06 : 7.85E-06 : 1.51E-03 : 1.71E-10 0.OOE+00 :

INFANT 6.40E-06 : 1.83E-06 : 4.47E-05 : 1.19E-05 : 1.37E-05 : 3.68E-03 : 3.93E-10 : O.OOE+00 :

GOATMILK :

ADULT

1.26E-06 2.03E-06 9.63E-06 1.85E-06 3.17E-06 5.74E-04 6.76E-12 0.OOE+00

-________+__________+__________+__________+___--+-

+-

-__+-_________+______---+-

_+-_______+

TEEN

2.15E-06 : 2.77E-06 : 1.77E-05 : 3.29E-06 : 5.66E-06 : 9.11E-04 : 1.36E-11 0.OOE+00 :

-________+__________+__________+__________+___--+-

+-

-__+-_________+______---+-

_+-_______+

CHILD

4.27E-06 : 2.24E-06 : 4.37E-05 : 5.74E-06 : 9.42E-06 : 1.82E-03 : 2.05E-11 0.OOE+00 :

-________+__________+__________+__________+___--+---+-+__-______+__________+______--+-__+-_______+

INFANT : 8.10E-06 : 2.25E-06 : 8.42E-05 : 1.40E-05 : 1.64E-05 : 4.41E-03 : 4.72E-11 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHA ADULT

7.08E-06 1.09E-05 : 8.03E-06 1.37E-05 : 1.13E-05 1.52E-04 3.71E-05 0.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

TEEN

9.75E-06 : 4.40E-05 : 1.13E-05 : 1.89E-05 : 1.56E-05 : 1.98E-04 : 6.11E-05 : 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-__+______-+__-__+

CHILD

1.21E-05 : 3.40E-04 : 1.54E-05 : 1.86E-05 : 1.47E-05 : 2.43E-04 : 5.33E-05 : 0.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-____+__-+__-__+

INFANT 8.66E-06 : 3.12E-04 : 1.21E-05 : 1.73E-05 : 9.67E-06 : 2.23E-04 : 5.OOE-05 : 0.00E+00 :

-+-- -

PTI

TABLE 7.

DOSES TO MAXIMUM INDIVIDUAL (MREM),

JANUARY-DECEMBER 2003 (CONTINUED)

SPECIAL LOCATION NO.

S A Nearest Garden AT 1.90 MILES NNW ANNUAL BETA AIR DOSE = 9.69E-03 MILLRADS ANNUAL GCAMMA AIR DOSE = 8. 61E-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+_____-____+________-_+_________-+_________-+_________-+__________+__________+_________-+

PLUME

5.69E-03 : 5.69E-03 : 5.69E-03
5.69E-03 : 5.69E-03 : 5.69E-03
5.79E-03 : 1.37E-02 :

-________+___

__+

_+_

+__

__+

_+_--+-

+

+

+

+

+

+__-

_+

GROUND 3.97E-04 : 3.97E-04 : 3.97E-04

3.97E-04 : 3.97E-04 : 3.97E-04
3.97E-04 : 4.65E-04 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

VEGET ADULT 1.63E-05 9.57E-05 2.51E-04 1.02E-05 1.21E-05 2.21E-03 3.61E-09 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-__+___+___+-___+

TEEN

2.55E-05 : 1.09E-04 : 4.16E-04 : 1.54E-05 : 1.82E-05 : 2.96E-03 : 6.49E-09 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-_____-+__-__+

CHILD

5.50E-05 : 7.96E-05 : 1.01E-03 : 2.50E-05 : 2.91E-05 : 5.67E-03 : 9.67E-09 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT ADULT 1.52E-06 1.22E-05 2.63E-06 8.03E-07 3.12E-07 5.86E-05 1.35E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-________-+___-__+

TEEN

1.21E-06 : 6.63E-06 : 2.22E-06 : 6.29E-07 : 2.54E-07 : 4.24E-05 : 1.26E-10 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-________+-+__-__+

CHILD

1.88E-06 : 3.40E-06 : 4.19E-06 : 7.68E-07 : 3.23E-07 : 6.41E-05 : 1.47E-10 : O.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK :

ADULT

3.61E-06 6.42E-06 1.52E-05 5.57E-06 9.32E-06 1.69E-03 1.80E-10 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-______+-+__-__+

TEEN

6.10E-06 : 8.30E-06
2.79E-05 : 9.88E-06 : 1.66E-05 : 2.68E-03
3.59E-10 : O.OOE+00

_________+__________+__________+__________+__________+__________+__________+__________+__________+

CHILD

1.18E-05 : 6.30E-06 : 6.86E-05 : 1.72E-05 : 2.76E-05 : 5.33E-03 : 5.38E-10 : O.OOE+00 :

INFANT : 2.21E-05 : 6.08E-06 : 1.34E-04 : 4.20E-05 : 4.81E-05 : 1.30E-02 : 1.22E-09 0.OOE+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GOA7TM4ILK :

ADULT

4.29E-06 6.25E-06 2.82E-05 6.52E-06 1.12E-05 2.03E-03 2.16E-11 O.OOE+00

-________+__________+__________+__________+__________+__________+__________+_---________+-+___-__+

TEEN

7.28E-06 : 8.52E-06 : 5.19E-05 : 1.16E-05 : 1.99E-05 : 3.21E-03 : 4.30E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_---________+-+___-__+

CHILD

1.43E-05 : 6.88E-06 : 1.28E-04 : 2.02E-05 : 3.32E-05 : 6.40E-03 : 6.45E-11 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-____+____-+__-__+

INFANT : 2.72E-05 : 6.90E-06 : 2.47E-04 : 4.95E-05 : 5.77E-05 : 1.56E-02 : 1.46E-10 : O.00E+00 :

_________+__________+__________+__________+__________+__________+__________+__________+__________+

INHAL ADULT 8.18E-06 1.34E-05 9.47E-06 1.61E-05 1.42E-05 3.76E-04 6.14E-05 O.00E+00

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-__+___+-___+

TEEN

1.12E-05 : 4.94E-05 : 1.33E-05 : 2.22E-05 : 1.96E-05 : 4.88E-04 : 9.72E-05 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-___-+__-__+

CHILD

1.39E-05 : 3.70E-04 : 1.81E-05 : 2.18E-05 : 1.84E-05 : 6.00E-04 : 8.29E-05 : O.OOE+00 :

-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+

INFANT : 9.94E-06 : 3.38E-04 : 1.43E-05 : 2.03E-05 : 1.22E-05 : 5.52E-04 : 7.03E-05 : O.OOE+00 :

+--------------------------------------------+

+----+-

+

+-+

IT1

TABLE 8.

DOSES TO POPULATION WITHIN 50 MILES, JANUARY-MARCH 2003 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+

PLUME 1.53E-04 : 1.53E-04 : 1.53E-04 : 1.53E-04 : 1.53E-04 : 1.53E-04 : 1.57E-04

4.12E-04 59.09% :

53.96% :

55.87% :

59.45% :

59.64% :

16.41% :

56.39% :

77.89%

_________+__________+__________+__________+__________+__________+__________+__________+__________+

GROUND 9.96E-05 : 9.96E-05 : 9.96E-05 : 9.96E-05 : 9.9E-05 : 9.96E-05 : 9.96E-05 : 1.17E-04 38.52% :

35.17% :

36.42% :

38.75% :

38.87% :

10.70% :

35.73% :

22.11%

-+__________+__________+

_________+__________+_

________+__________+_--+

+ ___-_

_ +

INHAL 1.83E-07

2.98E-06 3.76E-07 : 3.15E-07 : 4.10E-07 6.29E-05 : 2.19E-05 0.OOE+00

.07% :

1.05%

.14% :

.12% :

.16%

6.76% :

7.88% :

.00%

_________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

VEGET 3.60E-06 : 1.93E-05 : 1.61E-05 : 1.86E-06 : 2.22E-07 : 7.42E-06 : 9.OOE-11 0.OOE+00 1.39% :

6.82% :

5.90% :

.72% :

.09% :

.80% :

.00% :

.00%

_________+__________+__________+__________+__________+__________+__________+__________+__________+

COW MILK 1.53E-06 : 2.62E-06 : 4.25E-06 : 2.03E-06 : 3.11E-06 : 5.95E-04 : 8.24E-11 : O.OOE+00

.59% :

.93% :

1.56% :

.79% :

1.21% :

63.98% :

.00% :

.00%

_________+__________+__________+__________+__________+__________+__________+__________+__________+

MEAT 8.84E-07 : 5.87E-06 : 3.16E-07 : 4.14E-07 : 6.95E-08 : 1.26E-05 : 1.87E-11

0.OOE+00

.34% :

2.07% :

.12% :

.16% :

.03% :

1.35% :

.00% :

.00%

+-_________+____- _____+________-_+__________+__________+__________+__________+______-+

TOTAL*

2.58E-04 : 2.83E-04 : 2.73E-04 : 2.57E-04 : 2.5GE-04 : 9.31E-04 : 2.79E-04
5.30E-04

_________+_____-----------------------------------------------------------------

+----+-

++

++

+

iI

TABLE 9.

DOSES TO POPULATION WITHIN 50 MILES, APRIL-JUNE 2003 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-PEM)

PATHWAI T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+

PLUME 2.30E-03 : 2.30E-03 : 2.30E-03 : 2.30E-03 : 2.30E-03 : 2.30E-03 : 2.37E-03 : 6.19E-03 94.68% :

93.42% :

90.08% :

94.76% :

94.63% :

47.75% :

94.24% :

97.83%

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

GROUND 1.17E-04 : 1.17E-04 : 1.17E-04 : 1.17E-04 : 1.17E-04 : 1.17E-04 : 1.17E-04 : 1.37E-04 4.79% :

4.73% :

4.56% :

4.79% :

4.79% :

2.42% :

4.64% :

2.17%

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

INHAL 9.27E-07 : 4.56E-06 : 2.58E-06 : 1.99E-06 : 2.99E-06 : 3.13E-04 : 2.81E-05 0.OOE+00

.04% :

.19% :

.10% :

.08% :

.12% :

6.49% :

1.12% :

.00%

_________+______-___+_________-+________-_+________-_+_________-+________-_+________-_+________-_+

VEGET 6.47E-06 : 2.95E-05 : 1.09E-04 : 1.95E-06 : 3.09E-07 : 2.69E-05 : 2.33E-10 : O.OOE+00

.27% :

1.20% :

4.25% :

.08% :

.01% :

.56% :

.00% :

.00%

_________+-_________+_________-+_________-+_________-+________-_+________-_+________-_+________-_+

COW MILK 4.51E-06 : 5.11E-06 : 2.39E-05 : 6.49E-06 : 1.06E-05 : 2.02E-03 : 2.06E-10 0.OOE+00

.19% :

.21% :

.93% :

.27% :

.44% :

41.88% :

.00% :

.00%

_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+

MEAT 1.04E-06 : 6.54E-06 : 2.OOE-06 : 5.31E-07 : 2.31E-07 : 4.36E-05 : 6.69E-11 0.OOE+00

.04% :

.27% :

.08% :

.02% :

.01% :

.90% :

.00% :

.00%

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

  • TOIAL*
2.43E-03 : 2.47E-03 : 2.56E-03 : 2.43E-03 : 2.43E-03 : 4.82E-03 : 2.51E-03 : 6.33E-03

_________+__________+__________+-_____4_____+__________+_---_______+-4--_______+________+4--------

It1

TABLE 10.

DOSES TO POPULATION WITHIN 50 MILES, JXINUARY-JUNE 2003 ALARA ANNUAL INTEGRATED POPULATION DOSE STM4'MY (PERSON-REM)

PATHNAW T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+__________+_________-+________-_+________-_+________-_+_________-+________-_+

PLUlME 2.54E-03 : 2.54E-03 : 2.54E-03 : 2.54E-03 : 2.54E-03

2.54E-03 : 2.60E-03 : 6.80E-03 91.53% :

89.69% :

87.28% :

91.65% :

91.58% :

44.12% :

90.75% :

96.40%

_________+-_________+_______-__+_________-+________-_+_________-+_________-+________-_+________-_+

GROUND 2.16E-04 : 2.16E-04 : 2.16E-04 : 2.16E-04

2.16E-04
2.16E-04 : 2.16E-04
2.54E-04 7.79% :

7.63% :

7.42% :

7.80% :

7.79% :

3.75% :

7.52% :

3.60%

_________+-_________+_______-__+_________-+________-_+________-_+________-_+________-_+________-_+

INHAL 1.07E-06 : 7.34E-06 : 2.84E-06 : 2.22E-06 : 3.27E-06 : 3.63E-04 4.98E-05 : 0.00E+00

.04% :

.26% :

.10% :

.08% :

.12% :

6.32%

1.73% :

.00%

_________+______-___+________-_+__________+_________-+________-_+_________-+________-_+________-_+

VEGET 9.98E-06 : 4.85E-05 : 1.22E-04 : 3.81E-06 : 5.27E-07 : 3.36E-05 : 3.20E-10 0.OOE+00

.36% :

1.71% :

4.19% :

.14% :

.02% :

.58% :

.00% :

.00%

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

COW MILK 5.88E-06 : 7.61E-06 : 2.72E-05 : 8.29E-06 : 1.33E-05 : 2.54E-03 : 2.85E-10 0.OOE+00

.21% :

.27% :

.94% :

.30% :

.48% :

44.26% :

.00% :

.00%

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

MEAT

1.92E-06 : 1.24E-05 : 2.26E-06 : 9.42E-07 : 2.95E-07 : 5.51E-05 : 8.42E-11 0.OOE+00

.07% :

.44% :

.08% :

.03% :

.01% :

.96% :

.00% :

.00%

_________+-_________+_______-__+_________-+________-_+_________-+________-_+________-_+________-_+

  • TOTAL*
2.77E-03 : 2.83E-03
2.91E-03 : 2.77E-03 : 2.77E-03 : 5.75E-03 : 2.87E-03 : 7.05E-03

_________+__________+__________+__________+__________+__________+__________+__________+__________+

+++i+

TABLE 11.

DOSES TO POPULATION WITHIN 50 MILES, AIARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

JULY-SEPTEMBER 2003 PATHWAY T.BODY

-_______+-_________

PLUME 2.05E-03 97.21%

_________+__________

GROUND 3.82E-05 1.81%

-_______+-_________

INHAL

6.40E-06
.30%

________+-_________

VEGET 9.50E-06

.45%

-_______+-_________

COW MILK 4.50E-06

.21%

_________+__________

MEAT

3.49E-07
.02%

TOTA* :2.11E-03 GI-TRACT

+-________

2.05E-03 89.59%

4-+________

3.82E-05 1.67%

.+-________

1.57E-04 6.85%

+-________

3.42E-05 1.49%

.+-________

6.85E-06

.30%

+-________

2.08E-06

.09%

  • 2.29E-03 BONE 2.05E-03 82.65%

3.82E-05 1.54%

+-___ _ ____

1.16E-05

.47%

+-____ _____

3.16E-04 12.74%

+-__ __ _ __

5.86E-05 2.36%

+-__-___-__

5.90E-06

.24%

2.48E-03 LIVER

.+-________

2.05E-03 97.35%

.+-________

3.82E-05 1.81%

.+-________

1.22E-05

.58%

.+-________

2.17E-07

.01%

.+-________

5.19E-06

.25%

.+-________

1.52E-07

.01%

.+_________

+

2.11E-03 KIDNEY 2.05E-03 97.21%

.+-_

3.82E-05 1.81%

.+-_ _ ___

1.18E-05

.56%

.+-_

1.06E-07

.01%

.+-________

8.70E-06

.41%

.+-_--_--__

1.80E-07

.01%

2.11E-03 THYROID

.+_________

2.05E-03 48.10%

.+-_ ___

3.82E-05

.90%

.+-________

4.82E-04 11.30%

.+-____

2.03E-05

.47%

.+-________

1.64E-03 38.42%

3.43E-05

.80%

.+_________

4.27E-03 LUNG

.+-________

2.10E-03 94.38%

.+_________.

3.82E-05 1.72%

8.68E-05 3.90%

5.71E-10

. 00%

+-________

4.51E-10

.00%

.+-_________

2.77E-10

. 00%

2.22E-03 SKIN

+-_________+

5.24E-03 99.17%

__ +

4.41E-05

.83%

__ +

0.OOE+00

.00%

__ +

0.OOE+00

.00%

4-_________+

0.OOE+00

.00%:

4-_________+

0.OOE+00

.00%

____ +

5.29E-03

_______+________-_+__________+_______-4-+_________-+__________+__________+__________+__-4__+--

-4 NTJ-L11

TABLE 12.

DOSES TO POPULATION WITHIN 50 MILES, OCTOBER-DECEMBER 2003 ALARA ANNUAL INTEGRATED POPULATION DOSE

SUMMARY

(PERSON-REM)

PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+______-___+__________+_________-+________-_+________-_+________-_+_________-+________-_+

PLUM 1.79E-04 : 1.79E-04

1.79E-04 : 1.79E-04 : 1.79E-04 : 1.79E-04 : 1.82E-04 : 4.44E-04 93.27% :

88.34% :

62.92% :

93.47% :

91.76% :

9.81% :

91.50% :

98.17%

_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+

GROUND 7.05E-06 : 7.05E-06 : 7.05E-06 : 7.05E-06 : 7.05E-06 : 7.05E-06 : 7.05E-06 : 8.29E-06 3.66% :

3.47% :

2.47% :

3.67% :

3.60% :

.39% :

3.54% :

1.83%

_________+______-___+_________-+________-_+________-_+________-_+________-_+_________-+________-_+

INHAL 4.24E-07 : 4.61E-06 : 1.70E-06 : 8.96E-07 : 1.52E-06 : 2.01E-04

9.89E-06 0.OOE+00

.22% :

2.27% :

.60% :

.47% :

.78% :

10.98% :

4.96% :

.00%

_________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+

VEGET 2.47E-06 : 9.04E-06

7.88E-05 : 1.27E-07 : 9.11E-08 : 1.75E-05
1.68E-10 0.OOE+00 1.29% :

4.45% :

27.64% :

.07% :

.05% :

.95% :

.00% :

.00%

_________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+________-_+

COW MILK 2.85E-06 : 2.28E-06 : 1.67E-05 : 4.35E-06 : 7.31E-06 : 1.40E-03

1.27E-10 0.OOE+00 1.48% :

1.12% :

5.84% :

2.27% :

3.74% :

76.24% :

.00% :

.00%

_________+______-___+________-_+_________-+_________-+________-_+________-_+________-_+________-_+

MEAT 1.49E-07 : 7.26E-07 : 1.53E-06 : 1.13E-07 : 1.56E-07 : 2.97E-05 : 8.13E-11 0.OOE+00

.08% :

.36% :

.54% :

.06% :

.08% :

1.63% :

.00% :

.00%

_________+______-___+________-_+_________-+_________-+________-_+_________-+________-_+________-_+

  • TOTAL*
1.92E-04 : 2.03E-04 : 2.85E-04 : 1.92E-04 : 1.96E-04 : 1.83E-03 : 1.99E-04 : 4.52E-04

-________+_________-+_________-+_________-+__________+__________+__________+__________+__________+

  • IT1 00

TABLE 13.

DOSES TO POPULATION WITHIN 50 MILES, ALARA ANNUAL INTEGRATED POPULATION DOSE SUMMdARY (PERSON-REM)

JULY-DECEMBER 2003 PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+_____-____+________-_+_________-+__________+__________+__________+__________+_________-+

PLUME 2.21E-03 : 2.21E-03

2.21E-03 : 2.21E-03 : 2.21E-03 : 2.21E-03 : 2.26E-03
5.60E-03 96.97% :

89.51% :

80.98% :

97.09% :

96.82% :

36.58% :

94.21% :

99.12%

_________+-_________+________-_+_________-+________-_+________-_+________-_+________-_+________-_+

GROUND 4.29E-05 : 4.29E-05 : 4.29E-05 : 4.29E-05 4.29E-05 : 4.29E-05

4.29E-05
4.97E-05 1.88% :

1.73% :

1.57% :

1.88%

1.88% :

.71% :

1.79% :

.88%

_________+______-___+_________-+________-_+________-_+_________-+_________-+________-_+________-_+

INHAL 6.92E-06 : 1.63E-04

1.33E-05 1.32E-05 : 1.33E-05 : 6.70E-04 : 9.61E-05 : O.OOE+00

.30% :

6.58% :

.49%

.58% :

.58% :

11.08% :

4.00% :

.00%

_________+______-___+________-_+_________-+_________-+________-_+________-_+_________-+________-_+

VEGET 1.16E-05 : 4.21E-05 : 3.84E-04 : 3.44E-07 : 1.96E-07 : 3.76E-05 : 7.20E-10 0.OOE+00

.51% :

1.70% :

14.05% :

.02% :

.01% :

.62% :

.00% :

.00%

_________+-_________+_______-__+_________-+________-_+________-_+________-_+________-_+________-_+

COW MILK 7.25E-06 : 8.84E-06 : 7.25E-05 9.50E-06

1.59E-05 : 3.02E-03 : 5.57E-10 : O.OOE+00

.32% :

.36% :

2.65%

.42% :

.70% :

49.95% :

.00% :

.00%

_________+-_________+_________-+_________-+________-_+_________-+________-_+________-_+________-_+

MEAT 4.91E-07 : 2.76E-06 : 7.22E-06 : 2.65E-07 : 3.34E-07 : 6.38E-05 : 3.49E-10

O.OOE+00

.02% :

.11% :

.26% :

.01% :

.01% :

1.06% :

.00% :

.00%

_________+-_________+_______-__+________-_+_________-+_________-+________-_+________-_+________-_+

  • TOTAL*
2.28E-03 : 2.47E-03 : 2.73E-03 : 2.28E-03 : 2.29E-03 : 6.05E-03 : 2.40E-03
5.65E-03

-________ +__________+__________+__________+__________+__________+__________+__________-+____+---

D1

'.0

TABLE 14.

DOSES TO POPULATION WITHIN ALARA ANNUAL INTEGRATED POPULATION DOSE SMM4ARY (PERSON-REM) 50 MILES, JANUARY-DECEMBER 2003 PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN

-________+_____-____+________-_+__________+__________+__________+__________+___--+-+-__+_+______+

PLU!ME 4.76E-03 : 4.76E-03 : 4.76E-03 : 4.76E-03 : 4.76E-03 : 4.76E-03 : 4.87E-03

1.24E-02 93.91% :

89.71% :

84.16% :

94.04% :

93.88% :

40.36% :

92.28% :

97.57%

_________+______-___+________-_+__________+__________+__________+__________+___--+-+-____+______+

GROUND

2.64E-04 : 2.64E-04 : 2.64E-04 : 2.64E-04 : 2.64E-04
2.64E-04 : 2.64E-04 : 3.10E-04 5.21% :

4.98% :

4.67%.:

5.22% :

5.21% :

2.24% :

4.99% :

2.43%

_________+-_________+________-_+_________-+________-_+________-_+________-_+________-_+________-_+

INHAL 7.50E-06 : 1.59E-04

1.54E-05 : 1.45E-05 : 1.57E-05 : 1.01E-03
1.44E-04 : 0.OOE+00

.15% :

3.00% :

.27% :

.29% :

.31% :

8.58% :

2.73% :

.00%

_________+______-___+_________-+________-_+_________-+_________-+________-_+________-_+________-_+

VEGET

2.16E-05 : 9.06E-05 : 5.06E-04 : 4.15E-06 : 7.23E-07 : 7.12E-05 : 1.04E-09 : 0.OOE+00

.43% :

1.71% :

8.96% :

.08% :

.01% :

.60% :

.00% :

.00%

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

COW MILK : 1.31E-05 : 1.65E-05 : 1.OOE-04 : 1.78E-05

2.93E-05 : 5.56E-03 : 8.44E-10 : 0.OOE+00

.26% :

.31% :

1.77% :

.35% :

.58% :

47.20% :

.00% :

.00%

_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+

MEAT 2.41E-06 : 1.52E-05 : 9.45E-06 : 1.21E-06 : 6.30E-07 : 1.19E-04

4.31E-10 : 0.OOE+00

.05% :

.29% :

.17% :

.02% :

.01% :

1.01% :

.00% :

.00%

_________+-_________+____-_____+_________-+__________+-_________+__________+-_________+__-+

  • TOTAL*
5.06E-03 : 5.30E-03 : 5.65E-03 : 5.06E-03 : 5.07E-03 : 1.18E-02 : 5.28E-03 : 1.28E-02

-_________+__________+__________+__________+__________+________

4-

-+__________+__________+--

oz'TI U'

APPENDIX G REMP SAMPLE STATION DESCRIPTIONS G-1

REMP SAMPLE STATION DESCRIPTIONS The following pages contain descriptions of the CNS REMP Sample Stations that were active or were used for part or all of 2003.

G-2

REMP SAMPLE STATION DESCRIPTIONS SAMPLE TYPES AND SAMPLE LOCATIONS Sample Station (a)

Sample Description - Type and Location No. I Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Outside the northwest edge of fence, east of the gate to the LLRW storage pad on the CNS site, NW '4, S32, T5N, R16E, Nemaha County, Nebraska.

No. 2 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: North side of county road to the south portion of CNS site, SW 14, S32, T5N, RI6E, Nemaha County, Nebraska.

No. 3 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located on the north side of the Brownsville State Recreation Park access road near water gauging station, SE 1/4, S18, T5N, R16E, Nemaha County, Nebraska.

No. 4 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located 1/2 mile south of Phelps City, Missouri, on west side of highway "U", NE 14, S2, T64N, R42W, Atchison County, Missouri.

No. 5 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located 1/4 mile south and 1/4 mile east of Langdon, Missouri, on north side of road, west of railroad tracks, SW 1/4, T64N, R41W, Atchison County, Missouri.

No. 6 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: One mile west of the end of Missouri State Highway "U", SW corner of the intersection, NW 1/4, S34, T64N, R42W, Atchison County, Missouri.

G-3 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.

Sample Station Sample Description - Type and Location No 7 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: 300 yards east of Highway 67 on north side of road, SW 14, S6, T4N, RI6E, Nemaha, Nebraska.

No. 8 Type (I) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location:

1/2 mile north, 3/4 mile west and 3/4 mile north of Nemaha, on west side of road adjacent to transmission line, NE /4, S35, T5N, RI5E, Nemaha County, Nebraska.

No. 9 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Four miles north of Highway 136, on Highway 67.

Then I mile east of Highway 67 and 1/2 mile north on west side of road, SW 1/4, S26, T6N, RI 5E, Nemaha County, Nebraska.

No. 10 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: One mile north of Barada, Nebraska, in SW corner of intersection, NE 14, S14, T3N, Rl6E, Richardson County, Nebraska.

No. 11 Type: (1) Water-Ground Location: Plant well water supply header at well pits, NW 1/4, S32, T5N, RI6E, Nemaha County, Nebraska.

No. 12 Type: (1) Water-River Location: Sample (1) taken from the Missouri River immediately upstream form the Plant Intake Structure (River Mile 532.5). During periods when unsafe conditions warrant, Station 35 may be used as an alternate upstream collection site.

G4 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.

Sample Station Sample Description - Type and Location No.20 Type: (1) Environmental Thermoluminescent Dosimetry Location: On NNW boundary of NPPD property, east side of county road, SE, S30, T5N, R16E, Nemaha County, Nebraska.

No.28 Type (1) Water - River, (2) Fish (3) Sediment from Shoreline (4) Food Products - Broadleaf Vegetation Location: Samples (1), (3), and (4) are taken from the Missouri River or its shore downstream near River Mile 530, Sample (2) is taken from the Missouri River '/2 to 3 miles downstream of the plant site.

No. 35 Type (1) Fish (2) Water-River (Alternate Site)

(3) Food Products - Broadleaf Vegetation Location: Sample (1) will be taken from the Missouri River about I to 3 miles above the CNS intake structure. During periods when unsafe conditions warrant, Station 35 may be used as an alternate to Station 12 (upstream collection site) for sample type (2). Sample (3) is taken about 1/4 mile south of the Brownville State Recreation Area in Sector A.

No. 42 Type: (1) Milk - Other Producer Location: One mile south, I 1/4 miles east of Barada, Nebraska, south side of county road, NW 14, S30, T3N, RI 7E, Richardson County, Nebraska.

No. 44 Type: (1) Environmental Thermoluminescent Dosimetry Location:

1/4 mile south of Auburn Country Club on Highway 75, then 1/2 mile east of Highway 75 at fence line north of county road, SEI/4, S27, T5N, R14E, Nemaha County, Nebraska.

No. 47 Type: (1) Water-Ground Location: At Falls City Municipal water supply well.

G-5 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.

Sample Station Sample Description - Type and Location No. 56 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 1/4 miles SW of Langdon, Missouri, on Highway "U',

on the right side of the highway, NW 14, S23, T64N, R42W, Atchison County, Missouri.

No. 58 Type: (1) Environmental Thermoluminescent Dosimetry Location: Three miles south of Brownville, Nebraska, on county road, at the SE corner of the intersection with the farm road leading to Sample Station No. 2, SE1/4, S31, T5N, Rl6E, Nemaha County, Nebraska.

No. 59 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile SSE of the CNS Elevated Release Point, in the vicinity of the levee at the south boundary of NPPD property, SE 14, S32, T5N, RI 6E, Nemaha County, Nebraska.

No. 61 Type (1) Milk - Nearest Producer Location: One mile west of Brownville, Nebraska, on Highway 136, then I mile north on the county road, turn right and proceed approximately 1/2 mile east on south side of road, NWI/4, S13, T5N, R15E, Nemaha County, Nebraska.

No. 66 Type: (1) Environmental Thermoluminescent Dosimetry Location: Two miles south of Nemaha, Nebraska, on Highway 67

- east side of road, NW1/4, S19, T4N, RI6E, Nemaha County, Nebraska.

No. 67 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 miles west of Brownville, Nebraska, on Highway 136, then north I 1/2 miles on county road and east 1/2 mile, on north side of road, NEl/4, Sl l, T5N, RISE, Nemaha County, Nebraska.

G-6 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.

Sample Station Sample Description - Type and Location No. 71 Type: (1) Environmental Thermoluminescent Dosimetry Location: Two miles east of Phelps City, Missouri, on Highway 36, then south I 1/2 miles on county road and west 1/4 mile, SE1/4, S6, T64N, R41W, Atchison County, Missouri.

No. 79 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 7/8 miles south of Brownville, NE, on east side of paved road, NPPD property, SE1/4, S30, T5N, R16E, Nemaha County, Nebraska.

No. 80 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 1/8 miles south of Brownville, on east side of paved road, NPPD property, NEI/4, S31, T5N, R16E, Nemaha County, Nebraska.

No. 81 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 3/8 miles south of Brownville, Nebraska, in the NE corner of the intersection of the paved county road and CNS access road, NPPD property, NE1/4, S31, T5N, R16E, Nemaha County, Nebraska.

No. 82 Type: (1) Environmental Thermoluminescent Dosimetry Location: 7/8 mile south of CNS in a field, on NPPD property, SW1/4, S32, T5N, R16E, Nemaha County, Nebraska.

No. 83 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 1/4 miles south of Nemaha, Nebraska, on Highway 67, then east 1 mile to the junction of the driveway and county road (east side of drive), NE1/4, S19, T4N, R16E, Nemaha County, Nebraska.

No. 84 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 1/2 miles west of Brownville, NE, south side of Highway 136 west of Locust Grove School, NW1/4, S22, T5N, RI5E, Nemaha County, Nebraska.

G-7 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.

Sample Station Sample Description - Type and Location No. 85 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile east of Brownville, Nebraska, on Highway 136, then north /4 mile on the east side of the county road, NEI14, S33, T65N, R42W, Atchison County, Missouri.

No. 86 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then north I l/2 miles on Highway "D" on west side, SE1/4, S22, T65N, R42W, Atchison County, Missouri.

No. 87 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then south l/2 mile on county road and 3/4 mile west on county road to the end of the road, NWI/4, S3, T64N, R42W, Atchison County, Missouri.

No. 88 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then south 2 miles at the end of the county road, NWI/4, SlI, T64N, R42W, Atchison County, Missouri.

No. 89 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 I/2 miles south of Phelps City, Missouri, on Highway "U", then l/2 mile west in the SE corner of the county road intersection, NE 1/4, S14, T64N, R42W, Atchison County, Missouri.

No. 90 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 V/2 miles west and 3/4 mile south of Langdon, Missouri, on Highway "U", then l mile west, SWI/4, S23, T64N, R42W, Atchison County, Missouri.

G-8 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.

Sample Station Sample Description - Type and Location No. 91 Type: (1) Environmental Thermoluminescent Dosimetry Location:

1/2 mile west of Rockport, Missouri,on the south side of the intersection of U.S. Highway 136 and U.S.

Highway 275, at the south side of the water tower, NW1/4, S28, T65N, R41W, Atchison County, Missouri.

No. 94 Type: (1) Environmental Thermoluminescent Dosimetry Location:

1/4 mile of Langdon, Missouri, on the west side of the road, NE1/4, S24, T64N, R42W, Atchison County, Missouri.

No. 96 Type: (1) Food products - Broadleaf Vegetation Location: Approximately I mile south of Brownville, Nebraska, along the paved road, in the road ditch in Sector R, SWI/4, S19, T5N, R16E, Nemaha County, Nebraska.

No. 99 Type: (1) Milk (Nearest and Other Producer)

Location: 1 1/4 mile south of Shubert, Nebraska, on the west side of Highway 67, NE1/4, S24, T3N, RI SE, Richardson County, Nebraska.

No. 100 Type (1) Milk (Other Producer)

Location: Two miles south and 1 mile west of Shubert, Nebraska, SW1/4, S23, T3N, RISE, Richardson County, Nebraska.

No. 101 Type: (1) Food Products - Broadleaf Vegetation Location: 5 1 miles east and 1/2 mile north of Rock Port, Missouri, near the junction of Highway 136 and Highway 59, in Sector D, encompasses portions of several sections, Athison County, Missouri.

G-9 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.

No. 102 Type: (1) Milk (Other Producer)

Location: Two miles south and 3 miles east of Shubert, Nebraska, NW %A, S28, T3N, R15E Richardson County, Nebraska.

G-10 NOTES:

(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.