ML041270246

From kanterella
Jump to navigation Jump to search
Annual Radiological Environmental Operating Report (Areor), 01/01/2003 Through 12/31/2003
ML041270246
Person / Time
Site: Yankee Rowe
Issue date: 12/31/2003
From:
Yankee Atomic Electric Co
To:
NRC/FSME
References
-RFPFR
Download: ML041270246 (107)


Text

ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT (AREOR)

YANKEE ROWE STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM JANUARY 1, 2003 - DECEMBER 31, 2003 DOCKET NO. 50-29 LICENSE NO. DPR-3 YANKEE ATOMIC ELECTRIC COMPANY Rowe, Massachusetts AREVA DOC. # 47-5042986-00

TABLE OF CONTENTS 1.0 EXECUTIVE

SUMMARY

...............................................................................................................................................1

2.0 INTRODUCTION

.............................................................................................................................................................2 2.1 General Plant Site Information...............................................................................................2 2.2 Program Design...................................................................................................................2 2.3 Monitoring Zones.................................................................................................................3 2.4 Pathways Monitored............................................................................................................3 2.5 Descriptions of Monitoring Programs.....................................................................................5 2.5.1 Air Particulate Sampling.......................................................................................................................................5 2.5.2 River Water Sampling...........................................................................................................................................5 2.5.3 Ground Water Sampling.......................................................................................................................................5 2.5.4 Storm Drain Water Sampling................................................................................................................................6 2.5.5 Sediment Sampling................................................................................................................................................6 2.5.6 Milk Sampling.........................................................................................................................................................6 2.5.7 Fish Sampling.........................................................................................................................................................6 2.5.8 Food Product Sampling........................................................................................................................................6 2.5.9 Maple Syrup Sampling..........................................................................................................................................7 2.5.10 TLD Monitoring.......................................................................................................................................................7 3.0 RADIOLOGICAL DATA

SUMMARY

TABLES.......................................................................................................23 4.0 ANALYSIS OF ENVIRONMENTAL RESULTS........................................................................................................35 4.1 Sampling Program Deviations..............................................................................................35 4.2 Comparison of Achieved LLDs with Requirements................................................................35 4.3 Results Compared Against Reporting Levels..........................................................................35 4.4 Data Analysis by Media Type..............................................................................................36 4.4.1 Air Particulates.....................................................................................................................................................36 4.4.2 River Water...........................................................................................................................................................37 4.4.3 Ground Water.......................................................................................................................................................38 4.4.4 Storm Drain Water...............................................................................................................................................39 4.4.5 Sediment................................................................................................................................................................40 4.4.6 Fish........................................................................................................................................................................43 4.4.7 Food.......................................................................................................................................................................44 4.4.8 Maple Syrup.........................................................................................................................................................44 4.4.9 Direct Radiation...................................................................................................................................................45 5.0 OFF-SITE DOSE EQUIVALENT COMMITMENTS.................................................................................................48

6.0 REFERENCES

..................................................................................................................................................................49 APPENDIX A - LAND USE CENSUS FOR 2003.....................................................................................................................A-1 APPENDIX B - QUALITY ASSURANCE PROGRAM...........................................................................................................B-1 APPENDIX C -

SUMMARY

OF 2003 REMP DATA..............................................................................................................C-1

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 1

1.0 EXECUTIVE

SUMMARY

The radiological environmental monitoring program for the Yankee Rowe Nuclear Power Station was continued for the period January through December 2003, in compliance with the Yankee Decommissioning Quality Assurance Program (YDQAP) and the Off-Site Dose Calculation Manual (ODCM). This annual report was prepared for the Yankee Atomic Electric Company (YAEC) by the Nuclear & Radiation Engineering Group of AREVA (Framatome ANP). Normandeau Associates performed sample collection and preparation. Gamma exposure rate measurements and laboratory analyses were performed by AREVA Framatome ANP Environmental Laboratory (E-LAB).

Thermoluminescent dosimeters (TLDs) were used to measure direct gamma exposure in the vicinity of the station and as far away as 22.2 kilometers. Radiochemical and radiological analyses of samples were performed to detect the presence of any station-related radioactivity. Samples collected include air-particulate filters, broad leaf vegetation, well water, fruits, vegetables, river water, bottom sediment, and fish.

In evaluating the results of those analyses it is necessary to consider the variability of natural and man-made sources of radioactivity, distribution in the environment and uptake in environmental media. This variability is dependent on many factors including station release rates, past spatial variability of radioactive fallout from nuclear weapons tests and on-going redistribution of the fallout, contribution from cosmically produced radioactivity, ground water dynamics, soil characteristics, farming practices, and feed type. Any one of these factors could cause significant variations in measured levels of radioactivity. Therefore, these factors need to be considered in order to properly explain any variations in radiation detected and to distinguish between natural and station related radioactivity.

Yankee Rowe was permanently shutdown in 1991. Primary activities at the Yankee Rowe station are now focused on fuel storage, site remediation and facility decommissioning. Even though the station is no longer generating power, decommissioning activities include processing and discharging of liquids containing radioactivity and monitoring for any release of airborne radioactivity. However, the levels of radioactivity released are significantly lower than releases during plant operation. The radiological monitoring of the environment through this program will continue to assure the health and safety of the public are maintained at all times.

The predominant radioactivity detected by the monitoring program was that from outside sources, such as fallout from nuclear weapons tests and naturally occurring radionuclides. As typical of previous years, station-related radioactivity was observed in some of the monitoring samples. The specific observations of possible station effects included Cesium-137 in bottom sediment near the plant discharge point. Air sample results demonstrated that no plant-related airborne particulate activity was present in samples.

Milk sampling was discontinued due to absence of milk-producing animals in the plant vicinity. Milk was sampled since 2000 only at the control location in Williamstown, MA, 22 km from the plant due to the unavailability of milk form locations within 5 miles of the plant. The control location facility in Williamstown closed in December 2002.

LLDs for Mn-54, Zn-65, and Zr-Nb-95 were removed from the program as a result of changes to the YNPS ODCM.

These changes were prompted by the change in status of the plant as decommissioning continues.

During 2003, there were no other changes made to the radiological environmental monitoring program.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 2

2.0 INTRODUCTION

2.1 General Plant Site Information The Yankee Nuclear Power Station (YNPS) is located on a site of over 1800 acres in a predominantly rural area of northwestern Massachusetts, three-quarters of a mile south of the Vermont border. The plant resides in the town of Rowe, Massachusetts, approximately 9 air miles east-northeast of North Adams, Massachusetts. The surrounding area is heavily forested and lightly populated. Hills bounding the river valley rise 500 to 1000 feet above the site, reaching elevations of 2100 feet.

The Deerfield River is used extensively for hydroelectric power generation both upstream and downstream of YNPS.

Sherman Dam, immediately adjacent to YNPS, operates as a hydroelectric generating station. Sherman Pond, the impoundment behind this dam, has been used as a source of cooling water for YNPS.

YNPS voluntarily shut down on October 1, 1991 after 31 years of operation. The plant is involved in the process of decommissioning which involves the disassembly and removal of the plant components and structures. This process is taking place in strict conformance with USNRC regulations. Oversight of the decommissioning process will also continue from the U.S. Environmental Protection Agency, the Massachusetts Department of Environmental Protection, Massachusetts Department of Public Health, and Massachusetts Emergency Management Administration.

The radiological environmental monitoring program for YNPS continued during 2003 and will continue throughout the decommissioning period until its 10CFR50 license is terminated.

2.2 Program Design The Radiological Environmental Monitoring Program for the YNPS was designed with specific objectives in mind.

These were:

To provide an early indication of the appearance or accumulation of any radioactive material in the environment caused by YNPS activities.

To provide assurance to regulatory agencies and the public that the environmental impact from YNPS is known and within anticipated limits.

To verify the adequacy and proper functioning of station effluent controls and monitoring systems.

To provide standby monitoring capability for rapid assessment of risk to the general public in the event of unanticipated or accidental releases of radioactive material.

These objectives will continue to be in force, to varying degrees, throughout decommissioning activities at the YNPS site. Due to the shutdown status of the plant and due to the relatively low quantities of radioactive material now on the site, some of the objectives have a different degree of importance than in the past.

The radiological environmental monitoring program was initiated in 1958, approximately two years before the plant

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 3

began operation in 1960. It has been in operation continuously since that time, with improvements made periodically over those years. The program continued without modification following the shutdown of the plant in 1991 and was reduced in scope beginning in 1997 primarily to reflect the absence of short lived radionuclides in various pathways resulting from the plant shutdown (no source of production) and the individual radionuclides short half-life (long decay time since the shutdown).

The program was designed to meet the intent of NRC Regulatory Guide 4.1, Programs for Monitoring Radioactivity in the Environs of Nuclear Power Plants; NRC Regulatory Guide 4.8, Environmental Technical Specifications for Nuclear Power Plants; the NRC Branch Technical Position of November 1979 entitled, An Acceptable Radiological Environmental Monitoring Program; and NRC NUREG-0472, Radiological Effluent Technical Specifications for PWR's.

The environmental TLD program was designed and tested around NRC Regulatory Guide 4.13, Performance, Testing and Procedural Specifications for Thermoluminescence Dosimetry: Environmental Applications. The quality assurance program was designed around the guidance given in NRC Regulatory Guide 4.15, Quality Assurance for Radiological Monitoring Programs (Normal Operations) - Effluent Streams and the Environment.

The sampling requirements of the REMP are given in Table 4.1 of the ODCM and in Table 2.1 of this report. The identification of the required sampling locations is given in Table 4.4 of the ODCM and in Tables 2.2 and 2.3 of this report. The sampling and monitoring locations are shown graphically on the maps in Figures 2.1 through 2.6.

2.3 Monitoring Zones The REMP is designed to allow comparison of levels of radioactivity in samples from the area possibly influenced by the plant to levels found in areas not influenced by the plant. The first area locations are called "indicators", and the second area locations are called "controls." The distinction between the two areas, depending on the type of sample or sample pathway, is based on one or more of several factors, such as site meteorological history, meteorological dispersion calculations, relative direction from the plant, river flow, and distance. Analysis of survey data from the two areas aids in determining if there is a significant difference between the two areas. It can also help in differentiating between radioactivity or radiation due to plant activities and that due to other fluctuations in the environment, such as atmospheric nuclear weapons test fallout or seasonal variations in the natural background.

2.4 Pathways Monitored Four pathway categories are monitored by the REMP. They are airborne, waterborne, ingestion and direct radiation pathways. Each of these four categories is monitored by the collection of one or more sample media, which are listed below, and are described in more detail in this section:

  • Airborne Pathway

§ Air Particulate Sampling Section 2.5.1

  • Waterborne Pathways

§ River Water Sampling Section 2.5.2

§ Ground Water Sampling Section 2.5.3

§ Storm Drain Water Sampling Section 2.5.4

§ Sediment Sampling Section 2.5.5

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 5

  • Ingestion Pathways

§ Milk Sampling Section 2.5.6

§ Fish Sampling Section 2.5.7

§ Food Product (fruits & vegetables, Section 2.5.8 broad leaf vegetation)

§ Maple Syrup Sampling Section 2.5.9

  • Direct Radiation Pathway

§ TLD Monitoring Section 2.5.10 2.5 Descriptions of Monitoring Programs Sample types and frequency of analysis are given in Table 2.1. The sample locations are listed in Table 2.2 and Table 2.3 and shown in Figures 2.1 - 2.7. ODCM lower limits of detection (LLDs) and required reporting levels are listed in Tables 2.4 and 2.5. The program as described here includes both required samples as specified in the Off-Site Dose Calculation Manual (ODCM) and any extra samples. Following is a detailed description of the sampling program:

2.5.1 Air Particulate Sampling Continuous air samplers are installed at six locations, five of which are required by the YNPS ODCM. The sampling pumps at these locations operate continuously at a flow rate of approximately one cubic foot per minute. Airborne particulates are collected by passing air through a 47-mm glass-fiber filter. A dry gas meter is incorporated into the sampling stream to measure the total volume of air sampled in a given interval. The entire system is housed in a weatherproof structure. The filters are collected biweekly, and, to allow for the decay of radon daughter products, they are held for at least 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> at the E-LAB before being analyzed for gross-beta radioactivity (indicated as GR-B in the data tables). The biweekly filters are composited by location at the E-LAB for a quarterly gamma spectroscopy analysis.

2.5.2 River Water Sampling An automatic composite sampler is located at one downstream sampling location. The sampler is controlled by timers that collect an aliquot of river water at least every two hours over a period of one month. Grab samples are collected monthly at Sherman Pond and at one upstream location. All river water samples are preserved with HCl and NaHSO3, or HNO3, to prevent the plate out of potentially present radionuclides on the container walls. Each sample is analyzed for gross-beta and gamma-emitting radionuclides. The monthly samples are composited quarterly by location at the E-LAB for a H-3 analysis. The monthly H-3 samples are also analyzed as a non ODCM requirement.

2.5.3 Ground Water Sampling Grab samples are collected monthly from two on-site locations. The ODCM requires samp les to be collected at least once per quarter. Each sample is required by the ODCM to be analyzed for gamma-emitting radionuclides and H-3.

Samples are also analyzed for gross beta activity, which is not an ODCM requirement. Gross beta analyses are performed to gather additional data that may help to provide early detection of plant-related activity.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 6

2.5.4 Storm Drain Water Sampling Grab samples are collected monthly or as available from the East and West Storm Drain. These are not ODCM required sampling locations. This water is comprised of a network of storm drains connected to parking areas, associated facility, and administration building, as well as groundwater and precipitation (including snowmelt) draining from the east side and west side of the plant facility. Neither storm drain network is directly connected to any plant operation. Each sample is analyzed for gross-beta and gamma-emitting radionuclides and H-3.

2.5.5 Sediment Sampling Shoreline sediment cores are collected semiannually from two locations, one upstream and one downstream of the plant. At each location, six two-inch inner diameter plastic coring tubes are driven into the sediment at least six inches deep. The cores are carefully extracted and kept in an upright position and frozen prior to delivery to the E-LAB. At the E-LAB, the frozen cores are cut into 5 cm (two-inch) segments. For each location, the 0-5 cm segments are blended into a single sample, as are the 5-10 cm and 10-15 cm segments. These composite samples are then analyzed for gamma-emitting radionuclides.

An additional bottom sediment core is collected semiannually in Sherman Pond near the plant discharge. A Wildco K. B. Core Sampler, fitted with a plastic coring tube, is dropped from a boat. Six cores are collected here, and are processed and analyzed as described above.

2.5.6 Milk Sampling Samples collected to measure radionuclides in milk were discontinued in 2002 and this requirement was removed from the ODCM in 2003. Due to absence of milk-producing animals in the plant vicinity since 1999 this medium had been sampled since 2000 only at a control location in Williamstown, MA, 22 km from the plant. That facility closed in December 2002 and milk animals are no longer present there. Milk sampling was discontinued because the radionuclides that accumulate in milk are no longer potentially released from the plant, and no suitable indicator or control stations remain to provide samples.

2.5.7 Fish Sampling Fish samples are collected semiannually at two locations (upstream of the plant and in Sherman Pond). A gill net is set overnight from a boat, and mixed species of fish are removed the following day. The species typically collected are yellow perch, smelt, pickerel, trout, bullheads or suckers. The fish samples are frozen and delivered to the E-LAB where the edible portions are analyzed for gamma-emitting radionuclides.

2.5.8 Food Product Sampling Food products are collected annually (at harvest) at three locations. The samples are either tuberous vegetables, above-ground vegetables, or fruit. Two indicator locations are chosen as a result of the annual Land Use Census, based on meteorological dispersion calculations. The third location is a control, which is located sufficiently far away from the plant to be outside any potential influence from it. The edible portions of the samples are then analyzed at the E-LAB for gamma-emitting radionuclides.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 7

2.5.9 Maple Syrup Sampling Maple syrup is an important commercial product in northern New England, including the YNPS plant environs.

Consequently, samples are collected annually from two locations although there is no ODCM requirement. These samples are collected from the syrup manufacturer as a finished product, that is, following the boiling down of the maple sap. Since the samples have already been boiled down as part of the syrup production process, no preservatives are needed in the samples. Following collection, the samples are analyzed at the E-LAB for gamma-emitting radionuclides. It should be noted that because of the boiling down and filtering of the sap, the resulting radionuclide measurements do not represent actual environmental concentrations. It is estimated that the resulting syrup has been concentrated by a factor of from 15 to 120 times the original sap, depending mo stly on the time of the season that the sap was collected.

2.5.10 TLD Monitoring Direct gamma radiation exposure is continuously monitored with the use of thermoluminescent dosimeters (TLDs).

Specifically, Panasonic UD-801AS1 and UD-814AS1 calcium sulfate dosimeters are used, with a total of five elements in place at each monitoring location. Each pair of dosimeters is sealed in a plastic bag, which is in turn housed in a plastic-screened container. This container is attached to an object such as a tree, fence or utility pole. TLDs are posted at 33 locations, with 24 of these stations required by the ODCM. All the TLDs are read out quarterly.

Normandeau posts and retrieves all TLDs, while the E-LAB processes them.

During 2002 new sets of 16 TLDs were installed at locations to monitor the Independent Spent Fuel Storage Installation (ISFSI) prior to, during and following completion of fuel transfer. These locations are listed in Table 2.3. The ISFSI TLD monitoring is not part of the REMP program but will be incorporated in the program following structure demolition and license termination.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 8

TABLE 2.1 Radiological Environmental Monitoring Program (Sample Types, Collection Frequency, Analysis Requirements)

(as required by ODCM Table 4.1)

Collection Analysis Exposure Pathway And/or Sample Media Number of Sample Locations Routine Sampling Mode Collection Frequency Analysis Type Analysis Frequency

1. Direct Radiation ( TLDs) 24*

Continuous Quarterly Gamma Dose Each TLD

2. Airborne: Particulates 5

Continuous Once per two weeks Gross Beta Gamma Isotopic Each Sample Quarterly Composite by Location

3. Waterborne
a. Surface Water 1

Composite at two hour intervals -

Downstream Monthly Gross Beta Gamma Isotopic Tritium (H-3)

Each Sample Each Sample Quarterly Composite 1

Grab -Upstream Monthly

b. Ground Water 2

Grab Quarterly Gamma Isotopic Tritium (H-3)

Each Sample Each Sample

c. Shoreline Sediment 1

Grab Semiannually Gamma Isotopic Each Sample

  • Does not include Site Restricted Area fence locations and those TLDs associated with ISFSI pad monitoring.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 9

TABLE 2.1 (Continued)

Radiological Environmental Monitoring Program (Sample Types, Collection Frequency, Analysis Requirements)

(As required by ODCM Table 4.1)

Collection Analysis Exposure Pathway And/or Sample Media Nominal Number of Sample Locations Routine Sampling Mode Nominal Collection Frequency Analysis Type Analysis Frequency

4. Ingestion
a. Fish 2

Grab Semiannually (or seasonal if appropriate)

Gamma Isotopic on edible portions Each sample

b. Food Products Tuberous or above ground vegetables, or fruit 3

Grab At harvest Gamma Isotopic on edible portion Each sample

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 10 TABLE 2.2 Radiological Environmental Monitoring Locations (non-TLD) in 2003 Yankee Nuclear Power Station Distance Exposure Station From Plant Direction Pathway Code Station Description Typea (km)

From Plant 1.0 Airborne AP-11 Observation Stand I

0.5 NW AP-12 Monroe Bridge I

1.1 SW AP-13 Rowe School I

4.2 SE AP-14 Harriman Station I

3.2 N

AP-21 Williamstown, MA C

22.2 W

AP-31*

YAEC Visitors Center I

0.8 SW 2.0 Waterborne

a.

Surface WR-11 Bear Swamp Lower I

6.3 Down-river WR-21 Harriman Reservoir C

10.1 Up-river WR-31*

Sherman Pond I

0.1 N

b. Ground WG-11 Plant Potable I

On-site WG-12 Sherman Spring I

0.2 NW

c.

Storm Drain WW-51*

East Storm Drain I

On-site WW-52*

West Storm Drain I

On-site

d. Sediment SE-11 No. 4 Station I

36.2 Down-river SE-21 Harriman Reservoir C

10.1 Up-river SE-91*

Sherman Pond I

0.1 N

3.0 Ingestion

a.

Fish FH-11 Sherman Pond I

1.5 Near Discharge FH-21 Harriman Reservoir C

10.1 Up-river a I=Indicator Station, C=Control Station.

Additional stations not required by the ODCM Radiological Environmental Monitoring Program (Table 4.4).

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 11 TABLE 2.2 (Continued)

Radiological Environmental Monitoring Locations (non-TLD) in 2003 Yankee Nuclear Power Station Distance Exposure Station From Plant Direction Pathway Code Station Description Typea (km)

From Plant

b. Food Products TF-11 Monroe Bridge, MA I

1.3 SW TF-13 Monroe, MA I

1.9 WNW TF-21 Williamstown, MA C

21.0 WSW MS-33*

Rowe, MA I

1.0 S

(Maple Syrup)

MS-45*

Florida, MA C

10.5 WSW (Maple Syrup) a I=Indicator Station, C=Control Station.

  • Additional stations not required by the ODCM Radiological Environmental Monitoring Program

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 12 TABLE 2.3 Radiological Environmental Monitoring Locations (TLD) in 2003 Yankee Nuclear Power Station Station Code Station Description Typea Distance From Plant (km)c Direction From Plant GM-1 YAEC Visitors' Center I

0.8 SW GM-2 Observation Stand I

0.5 NW GM-3 Rowe School I

4.2 SE GM-4 Harriman Station I

3.2 N

GM-5 Monroe Bridge I

1.1 SW GM-6 Readsboro Road Barrier I

1.3 N

GM-7 Whitingham Line I

3.5 NE GM-8 Monroe Hill Barrier I

1.8 S

GM-9 Dunbar Brook I

3.2 SW GM-10 Cross Road I

3.5 E

GM-11 Adams High Line I

2.1 WNW GM-12 Readsboro, VT I

5.5 NNW GM-13b Restricted Area Fence F

0.08 WSW GM-14b Restricted Area Fence F

0.11 WNW GM-15b Restricted Area Fence F

0.08 NNW GM-16b Restricted Area Fence F

0.13 NNE GM-17b Restricted Area Fence F

0.14 ENE GM-18b Restricted Area Fence F

0.14 ESE GM-19b Restricted Area Fence F

0.16 SE GM-20b Restricted Area Fence F

0.16 SSE GM-21b Restricted Area Fence F

0.11 SSW GM-22 Heartwellville, VT C

12.6 NNW GM-23 Williamstown Substation C

22.2 W

GM-25 Whitingham, VT O

7.7 NNE GM-27 Number 9 Road O

7.6 ENE GM-29 Route 8A O

8.2 ESE a

I = Indicator TLD; C = Control TLD; O = Outer Ring TLD; F = Fenceline TLD.

b These TLDs are located inside of the site boundary and not, therefore, part of the REMP program. These were placed inside of the site boundary to provide early indication of the potential increase in site boundary dose due to plant-related activities.

c GM station distances and direction are from the plant stack.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 13 TABLE 2.3 (Continued)

Radiological Environmental Monitoring Locations (TLD) in 2003 Yankee Nuclear Power Station Station Code Station Description Typea Distance From Plant/ISFSI (km)

Direction From Plant/ISFSI GM-31 Legate Hill Road O

7.6c SSE GM-32 Rowe Road O

7.9c S

GM-33 Zoar Road O

6.9c SSW GM-35 Whitcomb Summit O

8.6c WSW GM-36 Tilda Road O

6.6c W

GM-38 West Hill Road O

6.6c NW GM-40 Readsboro Road I

0.7c W

IF-1 e ISFSI Security Fence IF 0.02 d WNW IF-2 e Observation Stand IF 0.56 d NW IF-3 e ISFSI Security Fence IF 0.02 d N

IF-4 e ISFSI Security Fence IF 0.03 d NE IF-5 e ISFSI Security Fence IF 0.05 d E

IF-6 e ISFSI Security Fence IF 0.02 d SE IF-7 e ISFSI Security Fence IF 0.02 d S

IF-8 e ISFSI Security Fence IF 0.04 d SW IF-9 e Restricted Area Fence IF 0.05 d SE IF-10 e Restricted Area Fence IF 0.05 d SSE IF-11 e Restricted Area Fence IF 0.14 d SW IF-12 e Restricted Area Fence IF 0.21 d N

IF-18 e YNPS CW Intake IF 0.24 d NNW IF-19e ISFSI Security Fence Admin. Building IF 0.17 d W

IF-20 e ISFSI Security Fence Gatehouse IF 0.24 d WNW IF-40 e Readsboro Road IF 0.70 d WNW a

I = Indicator TLD; C = Control TLD; O = Outer Ring TLD; F = Fenceline TLD, IF = ISFSI.

c GM station distances and direction are from the plant stack.

d IF station distances and direction from ISFSI pad.

e These TLDs monitor the YNPS ISFSI and are not part of the REMP program.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 14 TABLE 2.4 Environmental Lower Limit of Detection (LLD) Sensitivity Requirements from ODCM Table 4.3 Analysis Water (pCi/l)

Airborne Particulates or Gases (pCi/m3)

Fish (pCi/kg)

(wet)

Food Product (pCi/kg)

(wet)

Sediment (pCi/kg -dry)

Gross-Beta 4

0.01 H-3 2000 Co-58,60 15 130 Cs-134 15 0.05 130 60 150 Cs-137 18 0.06 150 80 180

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 15 TABLE 2.5 Reporting Levels for Radioactivity Concentrations In Environmental Samples from ODCM Table 4.2 Analysis Water (pCi/l)*

Airborne Particulates or Gases (pCi/m3)

Fish (pCi/kg)

Food Product (pCi/kg)

(wet)

H-3 30000 Mn-54 1000 30000 Co-58 1000 30000 Co-60 300 10000 Zn-65 300 20000 Zr-Nb-95 400 Cs-134 30 10 1000 1000 Cs-137 50 20 2000 2000 Reporting Level for non-drinking water pathways.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 16 Figure 2.1 Radiological Environmental Sampling Locations Within 1 Mile of Yankee Rowe Nuclear Power Station

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 17 Figure 2.2 Radiological Environmental Sampling Locations Within 12 Miles of Yankee Rowe Nuclear Power Station MS-45

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 18 Figure 2.3 Radiological Environmental Sampling Locations Outside 12 Miles of Yankee Rowe Nuclear Power Station

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 19 Figure 2.4 Environmental TLD Monitoring Locations Within 1 Mile of Yankee Rowe Nuclear Power Station

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 20 Figure 2.5 Environmental TLD Monitoring Locations Within 12 Miles of Yankee Rowe Nuclear Power Station

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 21 Figure 2.6 Environmental TLD Monitoring Locations Outside of 12 Miles from Yankee Rowe Nuclear Power Station

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 22 Figure 2.7 Environmental TLD Monitoring Locations For the ISFSI Facility at the Yankee Rowe Nuclear Power Station

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 23 3.0 RADIOLOGICAL DATA

SUMMARY

TABLES This section summarizes the analytical results of the environmental samples that were collected during 2003. These results, shown in Table 3.1, are presented in a format similar to that prescribed in the NRC's Radiological Assessment Branch Technical Position on Environmental Monitoring (Reference 1). The results are ordered by sample media type and then by radionuclide for the pathways described in Section 2.3. The units for each media type are also given. Table 3.2 provides the same information for TLD direct radiation measurements.

The left-most column contains the radionuclide of interest, the total number of analyses for that radionuclide in 2003, and the number of measurements which exceeded the Reporting Levels found in Table 4.2 of the YNPS ODCM. The latter are classified as "Non-routine" results. The second column lists the required Lower Limit of Detection (LLD) for those radionuclides, which have detection capability requirements as specified in the ODCM Table 4.3. The absence of a value in this column indicates that no LLD is specified in the ODCM for that radionuclide in that media. The target LLD for any analysis is typically 30-40 percent of the most restrictive required LLD. Occasionally the required LLD is not met. This is usually due to malfunctions in sampling equipment, which result in low sample volume. Such cases are addressed in Section 4.2.

For each radionuclide and media type, the remaining three columns summarize the data for the following categories of monitoring locations: (1) the Indicator stations, which are within the range of influence of the plant and which could conceivably be affected by plant activities; (2) the station which had the highest mean concentration during 2003 for that radionuclide; and (3) the Control stations, which are beyond the influence of the plant. Direct radiation monitoring stations (using TLDs) are grouped into Indicator, Outer Ring, Fenceline and Control stations.

In each of these columns, for each radionuclide, the following are given:

The mean value of all concentrations including negative values and values that are not considered detectable.

The lowest and highest concentration.

The number of detectable measurements divided by the total number of measurements.

A sample is considered to yield a "detectable measurement" when the concentration exceeds three times its associated standard deviation. The standard deviation on each measurement represents only the random uncertainty associated with the radioactive decay process (counting statistics), and not the propagation of all possible uncertainties in the analytical procedure.

The radionuclides reported in this section represent those that: 1) had a Reporting Level listed in Table 4.2 of the ODCM or, a LLD requirement in Table 4.3 of the ODCM, or 2) had a positive measurement of radioactivity, whether it was naturally-occurring or man-made; or 3) were of specific interest for any other reason. The radionuclides that are routinely analyzed and reported by the E-LAB in a gamma spectroscopy analysis includes: Ac-Th-228, Ag-108m, Ag-110m, Ba-140, Be-7, Ce-141, Ce-144, Co-57, Co-58, Co-60, Cr-51, Cs-134, Cs-137, Fe-59, I-131, K-40, La-140, Mn-54, Nb-95, Ru-103, Ru-106, Sb-124, Sb-125, Se-75, Zn-65 and Zr-95. In no case did a radionuclide not shown in Table 3.1 appear as a "detectable measurement" during 2003.

Data from direct radiation measurements made by TLDs are provided in Table 3.2 in a format essentially the same as above. The complete listing of quarterly TLD data is provided in Table 3.3. Table 3.4 contains a list of new TLDs placed to monitor the YNPS ISFSI. Locations of these, including two located offsite, are shown in Figures 2.4 and 2.7.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 24 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: Air Particulates (AP) UNITS: pCi/cubic meter Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

GR-B (155) 0.01 2.0E -2 13 2.3E -2 1.9E -2 (0)

( 8.8 - 39.5)E -3

( 9.6 - 39.5)E -3

( 9.7 - 43.6)E -3 (130/ 130)

(26/ 26)

(25/ 25)

Be-7 (24) 8.7E -2 13 8.8E -2 7.9E -2 (0)

( 6.4 - 11.0)E -2

( 7.1 - 10.5)E -2

( 6.5 - 9.8)E -2 (19/ 20)

(3/ 4)

(4/ 4)

Co-58 (24)

-2.1E -4 13 3.4E -4

-1.1E -4 (0)

( -2.3 - 1.7)E -3

( -5.4 - 17.0)E -4

( -6.9 - 5.7)E -4 (0/ 20)

(0/ 4)

(0/ 4)

Co-60 (24) 2.8E -5 31 2.5E -4

-1.5E -5 (0)

( -1.3 - 0.9)E -3

( -3.5 - 8.9)E -4

( -2.4 - 2.9)E -4 (0/ 20)

(0/ 4)

(0/ 4)

Cs-134 (24) 0.05 9.4E -5 13 4.8E -4 2.0E -4 (0)

( -7.7 - 15.8)E -4

( -3.8 - 15.8)E -4

( 4.0 - 33.0)E -5 (0/ 20)

(0/ 4)

(0/ 4)

Cs-137 (24) 0.06 2.4E -5 12 1.7E -4

-4.2E -4 (0)

( -5.3 - 8.0)E -4

( -4.3 - 6.4)E -4

( -6.2 - -1.5)E -4 (0/ 20)

(0/ 4)

(0/ 4)

Footnotes to Table 3.1:

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 25 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: Fish (FH) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

K-40 (4) 2.4E 3 11 2.4E 3 2.0E 3 (0)

( 2.3 - 2.4)E 3

( 2.3 - 2.4)E 3

( 2.0 - 2.0)E 3 (2/ 2)

(2/ 2)

(2/ 2)

Mn-54 (4) 1.1E 1 11 1.1E 1 8.5E 0 (0)

( 5.0 - 17.0)E 0

( 5.0 - 17.0)E 0

( 0.0 - 1.7)E 1 (0/ 2)

(0/ 2)

(0/ 2)

Co-58 (4) 130 2.0E 0 21 4.5E 0 4.5E 0 (0)

( -9.0 - 13.0)E 0

( -5.0 - 14.0)E 0

( -5.0 - 14.0)E 0 (0/ 2)

(0/ 2)

(0/ 2)

Fe-59 (4)

-3.9E 1 21 9.8E 1 9.8E 1 (0)

( -1.2 - 0.4)E 2

( -1.4 - 21.0)E 1

( -1.4 - 21.0)E 1 (0/ 2)

(0/ 2)

(0/ 2)

Co-60 (4) 130 3.5E 0 21 1.7E 1 1.7E 1 (0)

( 3.0 - 4.0)E 0

( 1.5 - 1.9)E 1

( 1.5 - 1.9)E 1 (0/ 2)

(0/ 2)

(0/ 2)

Zn-65 (4)

-1.1E 1 21

-9.0E 0

-9.0E 0 (0)

( -3.0 - 0.8)E 1

( -2.1 - 0.3)E 1

( -2.1 - 0.3)E 1 (0/ 2)

(0/ 2)

(0/ 2)

Cs-134 (4) 130 4.5E 0 11 4.5E 0

-4.0E 0 (0)

( -1.3 - 2.2)E 1

( -1.3 - 2.2)E 1

( -5.0 - -3.0)E 0 (0/ 2)

(0/ 2)

(0/ 2)

Cs-137 (4) 150 4.1E 1 11 4.1E 1 1.5E 1 (0)

( 2.4 - 5.7)E 1

( 2.4 - 5.7)E 1

( 1.3 - 1.7)E 1 (1/ 2)

(1/ 2)

(0/ 2)

Footnotes to Table 3.1:

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 26 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: Maple Syrup (MS) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

Be-7 (2) 2.3E 1 33 2.8E 1 NO DATA (0)

( 1.8 - 2.8)E 1 (0/ 2)

(0/ 1)

K-40 (2) 2.2E 3 45 2.3E 3 NO DATA (0)

( 2.2 - 2.3)E 3 (2/ 2)

(1/ 1)

Mn-54 (2)

-2.5E -1 33 4.0E -1 NO DATA (0)

( -9.0 - 4.0)E -1 (0/ 2)

(0/ 1)

Co-58 (2)

-2.0E -1 33 1.1E 0 NO DATA (0)

( -1.5 - 1.1)E 0 (0/ 2)

(0/ 1)

Co-60 (2)

-1.9E 0 33 5.0E -1 NO DATA (0)

( -4.3 - 0.5)E 0 (0/ 2)

(0/ 1)

Zn-65 (2)

-9.6E 0 33

-6.6E 0 NO DATA (0)

( -1.3 - -0.7)E 1 (0/ 2)

(0/ 1)

Zr-95 (2)

-3.0E -1 33 1.3E 0 NO DATA (0)

( -1.9 - 1.3)E 0 (0/ 2)

(0/ 1)

Cs-134 (2) 60 1.0E 0 45 3.3E 0 NO DATA (0)

( -1.2 - 3.3)E 0 (0/ 2)

(0/ 1)

Cs-137 (2) 80 1.5E 1 45 1.8E 1 NO DATA (0)

( 1.2 - 1.8)E 1 (2/ 2)

(1/ 1)

Ba-140 (2) 5.0E -2 33 9.0E -1 NO DATA (0)

( -8.0 - 9.0)E -1 (0/ 2)

(0/ 1)

Th-232 (2) 1.4E 1 33 1.6E 1 NO DATA (0)

( 1.3 - 1.6)E 1 (0/ 2)

(0/ 1)

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 27 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: Sediment (SE) UNITS: pCi/kg dry Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

Be-7 (18)

-5.7E 1 11 1.3E 1

-3.2E 1 (0)

( -5.1 - 1.8)E 2

( -3.4 - 1.8)E 2

( -1.9 - 1.0)E 2 (0/ 12)

(0/ 6)

(0/ 6)

K-40 (18) 2.1E 4 91 2.6E 4 1.7E 4 (0)

( 1.4 - 2.8)E 4

( 2.5 - 2.8)E 4

( 1.4 - 2.0)E 4 (12/ 12)

(6/ 6)

(6/ 6)

Co-58 (18)

-1.6E 0 91 1.0E 0

-3.5E 0 (0)

( -3.6 - 2.6)E 1

( -3.6 - 2.6)E 1

( -2.0 - 0.9)E 1 (0/ 12)

(0/ 6)

(0/ 6)

Co-60 (18) 1.4E 0 91 1.2E 1

-6.6E 0 (0)

( -6.3 - 5.7)E 1

( -6.3 - 5.7)E 1

( -3.1 - 1.1)E 1 (0/ 12)

(0/ 6)

(0/ 6)

Cs-134 (18) 150 2.2E 1 91 3.2E 1

-5.8E 0 (0)

( -3.2 - 11.3)E 1

( -3.2 - 11.3)E 1

( -5.8 - 1.5)E 1 (0/ 12)

(0/ 6)

(0/ 6)

Cs-137 (18) 180 8.9E 2 91 1.6E 3 2.2E 2 (0)

( 1.3 - 19.4)E 2

( 1.1 - 1.9)E 3

( 3.2 - 85.3)E 1 (12/ 12)

(6/ 6)

(5/ 6)

Th-232 (18) 1.2E 3 91 1.5E 3 5.5E 2 (0)

( 8.3 - 17.0)E 2

( 1.1 - 1.7)E 3

( 4.9 - 6.4)E 2 (12/ 12)

(6/ 6)

(6/ 6)

Footnotes to Table 3.1:

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 28 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: Food Crop (TF) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

K-40 (3) 3.7E 3 13 6.4E 3 1.8E 3 (0)

( 9.7 - 63.6)E 2 (2/ 2)

(1/ 1)

(1/ 1)

Co-58 (3) 7.5E 0 11 1.7E 1

-2.0E 0 (0)

( -2.0 - 17.0)E 0 (0/ 2)

(0/ 1)

(0/ 1)

Co-60 (3) 6.5E 0 13 1.1E 1

-1.5E 1 (0)

( 2.0 - 11.0)E 0 (0/ 2)

(0/ 1)

(0/ 1)

I-131 (3)

-2.1E 1 21 1.2E 1 1.2E 1 (0)

( -3.8 - -0.4)E 1 (0/ 2)

(0/ 1)

(0/ 1)

Cs-134 (3) 60

-6.5E 0 11

-6.0E 0

-1.6E 1 (0)

( -7.0 - -6.0)E 0 (0/ 2)

(0/ 1)

(0/ 1)

Cs-137 (3) 80 3.0E 0 11 3.0E 0

-3.4E 0 (0)

( 3.0 - 3.0)E 0 (0/ 2)

(0/ 1)

(0/ 1)

Footnotes to Table 3.1:

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 29 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: Ground Water (WG) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

GR-B (26) 4 5.2E 0 12 7.0E 0 NO DATA (0)

( 1.6 - 9.5)E 0

( 4.9 - 9.5)E 0 (21/ 26)

(13/ 13)

H-3 (26) 2000 3.8E 1 12 8.2E 1 NO DATA (0)

( -2.1 - 3.6)E 2

( -1.1 - 3.6)E 2 (0/ 26)

(0/ 13)

Mn-54 (26)

-5.3E -1 12 5.0E -2 NO DATA (0)

( -3.6 - 1.8)E 0

( -3.6 - 1.8)E 0 (0/ 26)

(0/ 13)

Co-58 (26) 15

-8.9E -1 11

-7.8E -1 NO DATA (0)

( -3.3 - 2.7)E 0

( -2.3 - 2.7)E 0 (0/ 26)

(0/ 13)

Fe-59 (26) 9.6E -1 11 1.2E 0 NO DATA (0)

( -8.5 - 6.5)E 0

( -8.5 - 6.5)E 0 (0/ 26)

(0/ 13)

Co-60 (26) 15 5.4E -1 11 5.9E -1 NO DATA (0)

( -3.5 - 3.2)E 0

( -1.4 - 2.2)E 0 (0/ 26)

(0/ 13)

Zn-65 (26)

-1.5E 0 12

-1.3E 0 NO DATA (0)

( -1.6 - 1.3)E 1

( -9.9 - 13.0)E 0 (0/ 26)

(0/ 13)

Zr-95 (26) 1.5E -1 12 6.3E -1 NO DATA (0)

( -6.9 - 5.8)E 0

( -4.4 - 5.8)E 0 (0/ 26)

(0/ 13)

Cs-134 (26) 15 3.5E -3 12 2.3E -1 NO DATA (0)

( -2.6 - 1.8)E 0

( -1.8 - 1.8)E 0 (0/ 26)

(0/ 13)

Cs-137 (26) 18

-9.4E -1 12 1.1E -1 NO DATA (0)

( -4.2 - 1.7)E 0

( -1.3 - 1.7)E 0 (0/ 26)

(0/ 13)

Ba-140 (26) 1.3E 0 11 2.0E 0 NO DATA (0)

( -3.8 - 8.6)E 0

( -1.3 - 8.6)E 0 (0/ 26)

(0/ 13)

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 30 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: River Water (WR) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

GR-B (39) 4 2.2E 0 31 2.8E 0 2.0E 0 (0)

( -3.7 - 160.0)E -1

( -3.7 - 160.0)E -1

( 3.6 - 31.5)E -1 (4/ 26)

(3/ 13)

(2/ 13)

H-3 (51) 2000

-2.9E 1 11 4.3E 1

-3.0E 1 (0)

( -7.8 - 9.5)E 2

( -7.8 - 9.5)E 2

( -6.7 - 3.1)E 2 (0/ 34)

(0/ 17)

(0/ 17)

Mn-54 (39) 1.6E -1 31 3.7E -1 1.5E -2 (0)

( -3.4 - 3.6)E 0

( -3.4 - 3.6)E 0

( -1.6 - 1.8)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Co-58 (39) 15

-9.2E -1 21

-3.5E -1

-3.5E -1 (0)

( -3.9 - 2.2)E 0

( -3.5 - 3.3)E 0

( -3.5 - 3.3)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Fe-59 (39) 5.8E -2 31 4.2E -1

-1.5E 0 (0)

( -6.4 - 5.7)E 0

( -6.4 - 5.7)E 0

( -7.0 - 2.5)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Co-60 (39) 15 2.1E -2 21 5.2E -1 5.2E -1 (0)

( -3.1 - 2.5)E 0

( -2.6 - 2.9)E 0

( -2.6 - 2.9)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Zn-65 (39)

-1.8E 0 31

-9.0E -1

-1.4E 0 (0)

( -6.9 - 6.2)E 0

( -5.5 - 6.2)E 0

( -8.1 - 8.1)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Zr-95 (39)

-9.1E -1 31

-6.9E -1

-9.5E -1 (0)

( -5.5 - 2.5)E 0

( -5.5 - 2.3)E 0

( -4.9 - 4.2)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Cs-134 (39) 15

-1.0E -1 31

-3.8E -2

-2.5E -1 (0)

( -2.7 - 2.6)E 0

( -2.1 - 2.6)E 0

( -3.2 - 4.2)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Cs-137 (39) 18

-1.5E -1 11 2.8E -1

-9.2E -2 (0)

( -3.7 - 2.8)E 0

( -2.2 - 1.8)E 0

( -3.0 - 2.0)E 0 (0/ 26)

(0/ 13)

(0/ 13)

Ba-140 (39) 5.5E -1 11 1.0E 0 9.2E -2 (0)

( -4.4 - 10.5)E 0

( -3.8 - 10.5)E 0

( -5.4 - 6.7)E 0 (0/ 26)

(0/ 13)

(0/ 13)

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 31 Table 3.1 Radiological Environmental Program Summary Yankee Nuclear Power Station, Rowe, MA (January - December 2003)

MEDIUM: Storm Drain Water (WW) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides*

Mean Station Mean Mean (No. Analyses)

Required Range Range Range Non-Routine**

LLD No. Detected***

No. Detected***

No. Detected***

GR-B (24) 4 9.7E 0 51 1.0E 1 NO DATA (0)

( 1.9 - 19.4)E 0

( 1.9 - 19.4)E 0 (21/ 24)

(9/ 11)

H-3 (24) 2000

-1.4E 2 51

-9.9E 1 NO DATA (0)

( -8.9 - 5.0)E 2

( -8.9 - 5.0)E 2 (0/ 24)

(0/ 11)

Mn-54 (24) 15

-5.3E -2 51 1.1E -1 NO DATA (0)

( -3.5 - 2.4)E 0

( -2.7 - 2.4)E 0 (0/ 24)

(0/ 11)

Co-58 (24) 15

-1.2E -1 51

-9.1E -2 NO DATA (0)

( -2.2 - 2.6)E 0

( -2.2 - 2.6)E 0 (0/ 24)

(0/ 11)

Fe-59 (24)

-3.2E -1 51 2.7E -2 NO DATA (0)

( -7.3 - 8.3)E 0

( -6.0 - 8.3)E 0 (0/ 24)

(0/ 11)

Co-60 (24) 15

-2.5E -2 51 3.9E -1 NO DATA (0)

( -3.4 - 3.0)E 0

( -1.9 - 3.0)E 0 (0/ 24)

(0/ 11)

Zn-65 (24)

-2.7E 0 52

-1.4E 0 NO DATA (0)

( -1.0 - 0.7)E 1

( -1.0 - 0.7)E 1 (0/ 24)

(0/ 13)

Zr-95 (24) 6.8E -1 52 1.2E 0 NO DATA (0)

( -2.9 - 5.2)E 0

( -2.0 - 5.2)E 0 (0/ 24)

(0/ 13)

Cs-134 (24) 15

-6.7E -1 51

-5.2E -1 NO DATA (0)

( -5.9 - 2.1)E 0

( -3.0 - 2.1)E 0 (0/ 24)

(0/ 11)

Cs-137 (24) 18 1.9E -1 51 4.0E -1 NO DATA (0)

( -2.9 - 2.3)E 0

( -1.5 - 1.7)E 0 (0/ 24)

(0/ 11)

Ba-140 (24)

-7.2E -1 52

-3.8E -2 NO DATA (0)

( -7.2 - 4.2)E 0

( -7.2 - 4.2)E 0 (0/ 24)

(0/ 13)

  • The only radionuclides reported in this table are those with LLD requirements and those for which positive radioactivity was detected or which were considered important due to past effluent history.

See Section 5 of this report for a discussion of other radionuclides that were analyzed.

    • Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table 4.2.
      • The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 32 TABLE 3.2 ENVIRONMENTAL TLD DATA

SUMMARY

(JANUARY - DECEMBER 2003)

INDICATOR TLDs OUTER RING TLDs FENCELINE TLDs**

CONTROL TLDS MEAN MEAN MEAN MEAN RANGE RANGE RANGE RANGE (N0. MEASUREMENTS)* (N0. MEASUREMENTS)* (N0. MEASUREMENTS)* (N0. MEASUREMENTS)*

6.4

+/- 0.7 6.3

+/-

0.9 9.0 +/- 3.9 6.9 +/- 0.4 4.8 7.9 4.6 8.1 6.4 24.4 6.2 - 7.3 (52)

(36)

(36)

(8)

OFFSITE STATION WITH HIGHEST MEAN MEAN STA.

RANGE NO.

(NO. MEASUREMENTS)*

GM-38 7.6

+/-

0.5 7.0 8.1 (4)

  • Each measurement is based on quarterly readings from five TLD elements. Measurement units are µR/hr.
    • Not part of REMP Program (TLD locations are inside the site boundary). Increased exposure rates are due to fuel placement on the ISFSI which began in the 2nd half of 2002. Fuel and GTCC placement was completed in June 2003.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 33 TABLE 3.3 2003 ENVIRONMENTAL TLD MEASUREMENTS*

(Micro-R per hour) 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Annual Average Sta.

No.

Description Expos.

SD***

Expos.

SD***

Expos.

SD***

Expos.

SD***

Expos.

GM01 YNPS Visitors Center 4.72

+/- 0.42 6.60

+/- 0.33 6.03

+/- 0.32 6.12

+/- 0.37 5.9 GM02 Observation Stand 4.19

+/- 0.25 6.90

+/- 0.50 6.66

+/- 0.39 6.88

+/- 0.41 6.2 GM03 Rowe School 4.05

+/- 0.36 6.14

+/- 0.47 5.63

+/- 0.27 5.93

+/- 0.38 5.4 GM04 Harriman Station.

4.46

+/- 0.48 6.50

+/- 0.37 6.07

+/- 0.29 6.21

+/- 0.47 5.8 GM05 Monroe Bridge 5.31

+/- 0.45 7.68

+/- 0.52 7.17

+/- 0.39 7.29

+/- 0.50 6.9 GM06 Readsboro Rd. Barrier 4.67

+/- 0.30 7.62

+/- 0.33 7.31

+/- 0.45 7.34

+/- 0.48 6.7 GM07 Whitingham Line 4.93

+/- 0.35 7.32

+/- 0.34 8.10

+/- 0.35 7.49

+/- 0.53 7.0 GM08 Monroe Hill Barrier 4.63

+/- 0.28 6.81

+/- 0.29 6.13

+/- 0.33 6.19

+/- 0.41 5.9 GM09 Dunbar Brook 4.86

+/- 0.27 7.26

+/- 0.26 7.29

+/- 0.42 6.93

+/- 0.50 6.6 GM10 Cross Road 4.62

+/- 0.29 6.39

+/- 0.38 6.58

+/- 0.38 6.72

+/- 0.52 6.1 GM11 Adams High Line 4.47

+/- 0.29 6.93

+/- 0.26 6.67

+/- 0.36 6.41

+/- 0.52 6.1 GM12 Readsboro, VT 6.85

+/- 0.34 8.01

+/- 0.39 7.50

+/- 0.34 7.81

+/- 0.45 7.5 GM13 Indust. Area Fence**

6.43

+/- 0.44 10.37

+/- 0.44 9.99

+/- 0.46 9.92

+/- 0.55 9.2 GM14 Indust. Area Fence**

5.87

+/- 0.49 7.96

+/- 0.45 7.51

+/- 0.33 7.52

+/- 0.52 7.2 GM15 Indust. Area Fence**

6.23

+/- 0.37 8.67

+/- 0.37 7.80

+/- 0.48 7.96

+/- 0.47 7.7 GM16 Indust. Area Fence**

7.22

+/- 0.46 9.99

+/- 0.35 6.98

+/- 0.33 7.26

+/- 0.42 7.9 GM17 Indust. Area Fence**

6.10

+/- 0.34 9.02

+/- 0.43 8.86

+/- 0.35 8.89

+/- 0.69 8.2 GM18 Indust. Area Fence**

14.13

+/- 0.98 32.43

+/- 1.55 29.31

+/- 1.03 27.78

+/- 1.67 25.9 GM19 Indust. Area Fence**

32.62

+/- 2.88 36.58

+/- 1.88 38.78

+/- 2.00 38.04

+/- 2.71 36.5 GM20 Indust. Area Fence**

11.07

+/- 1.03 15.69

+/- 0.69 14.74

+/- 0.87 15.42

+/- 0.85 14.2 GM21 Indust. Area Fence**

5.96

+/- 0.45 8.70

+/- 0.50 8.03

+/- 0.35 8.53

+/- 0.60 7.8 GM22 Heartwellville, VT 4.87

+/- 0.38 7.56

+/- 0.31 7.62

+/- 0.36 7.31

+/- 0.52 6.8 GM23 Williamstown.Subst.

6.42

+/- 0.40 7.95

+/- 0.53 7.26

+/- 0.53 7.29

+/- 0.60 7.2 GM25 Whitingham 4.58

+/- 0.29 5.96

+/- 0.31 6.13

+/- 0.49 5.81

+/- 0.41 5.6 GM27 No.9 Road 4.20

+/- 0.25 6.01

+/- 0.34 6.06

+/- 0.28 6.10

+/- 0.40 5.6 GM29 Route 8A 3.81

+/- 0.22 5.35

+/- 0.33 5.69

+/- 0.41 5.0 GM31 Legate Road 4.37

+/- 0.33 6.36

+/- 0.32 6.19

+/- 0.34 6.25

+/- 0.53 5.8 GM32 Rowe Road 4.87

+/- 0.45 6.52

+/- 0.29 6.57

+/- 0.32 7.44

+/- 0.98 6.4 GM33 Zoar Road 5.27

+/- 0.31 6.63

+/- 0.35 6.45

+/- 0.38 6.78

+/- 0.44 6.3 GM35 Whitcomb Subst.

4.12

+/- 0.37 7.24

+/- 0.27 7.36

+/- 0.36 7.71

+/- 0.58 6.6 GM36 Tilda Road 4.57

+/- 0.33 7.13

+/- 0.62 6.81

+/- 0.33 7.13

+/- 0.43 6.4 GM38 West Hill Rd 4.91

+/- 0.34 8.05

+/- 0.35 8.13

+/- 0.42 8.14

+/- 0.48 7.3 GM40 Readsboro Rd 4.56

+/- 0.35 7.06

+/- 0.31 6.67

+/- 0.38 6.89

+/- 0.49 6.3

  • Each measurement is based on quarterly readings from five TLD elements.
    • Not part of the REMP Program. Increased exposure rates inside the site boundary are due to fuel placement on the ISFSI which began in the 2nd half of 2002. Fuel and GTCC placement was completed in June 2003.
      • SD: Standard Deviation

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 34 TABLE 3.4 2003 ISFSI TLD MEASUREMENTS*

(Micro-R per hour) 1st Quarter 2nd Quarter 3rd Quarter 4

th Quarter Annual Average Sta.

No.

Description Expos.

SD***

Expos.

SD***

Expos.

SD***

Expos.

SD***

Expos.

IF-1 ISFSI Security Fence**

352.74

+/- 32.71 451.01

+/- 22.00 416.27

+/- 9.04 393.25

+/- 7.78 403.0 IF-2 Observation Stand**

5.33

+/- 0.35 6.64

+/- 0.37 6.79

+/- 0.25 7.28

+/- 0.27 6.5 IF-3 ISFSI Security Fence**

373.06

+/- 19.18 510.52

+/- 17.93 479.48

+/- 32.95 447.46

+/- 24.11 452.6 IF-4 ISFSI Security Fence**

61.97

+/- 2.99 134.07

+/- 6.06 151.01

+/- 3.30 156.03

+/- 6.07 125.8 IF-5 ISFSI Security Fence**

202.01

+/- 11.00 280.35

+/- 11.14 281.82

+/- 8.01 274.71

+/- 15.28 259.7 IF-6 ISFSI Security Fence**

330.11

+/- 16.69 364.68

+/-14.73 381.07

+/- 32.12 374.67

+/- 15.42 362.6 IF-7 ISFSI Security Fence**

185.36

+/- 9.70 195.93

+/- 7.68 207.83

+/- 6.84 183.2

+/- 24.77 193.1 IF-8 ISFSI Security Fence**

21.75

+/- 1.56 40.45

+/- 1.67 41.14

+/- 1.56 37.41

+/- 2.23 35.2 IF-9 Restricted Area Fence**

44.86

+/- 2.70 51.6

+/- 1.97 55.61

+/- 7.25 57.22

+/- 1.33 52.3 IF-10 Restricted Area Fence**

23.54

+/- 1.60 27.72

+/- 1.18 26.28

+/- 0.81 26.13

+/- 0.82 25.9 IF-11 Restricted Area Fence**

9.37

+/- 1.21 12.25

+/- 0.47 11.96

+/- 0.50 11.84

+/- 0.43 11.4 IF-12 Restricted Area Fence**

7

+/- 0.49 7.19

+/- 0.38 8.04

+/- 0.35 7.79

+/- 0.31 7.5 IF-18 YNPS CW Intake**

6.12

+/- 0.37 8.41

+/- 0.38 7.02

+/- 0.26 7.16

+/- 0.26 7.2 IF-19 ISFSI Security Fence Admin. Building**

7.69

+/- 0.53 7.27

+/- 0.56 10.45

+/- 0.57 10.24

+/- 0.53 8.9 IF-20 ISFSI Security Fence Gatehouse**

7.37

+/-.046 9.65

+/- 0.53 8.31

+/- 0.51 8.77

+/- 0.23 8.5 IF-40 Readsboro Road**

4.88

+/- 0.35 8.08

+/- 0.39 7.47

+/- 0.36 7.23

+/- 0.38 6.9

  • Each measurement is based on quarterly readings from five TLD elements.
    • Not part of the REMP Program. Increased exposure rates for locations inside the site boundary are due to fuel placement on the ISFSI which began in the 2nd half of 2002. Fuel and GTCC placement was completed in June 2003.
      • SD: Standard Deviation

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 35 4.0 ANALYSIS OF ENVIRONMENTAL RESULTS 4.1 Sampling Program Deviations ODCM Control 4.1 allows for deviations "if specimens are unobtainable due to hazardous conditions, seasonal unavailability or malfunction of automatic sampling equipment." There were no program deviations noted in the REMP during 2003.

During the week of January 15th, the sampling pump for the air particulate sampling station 21 failed causing a low volume sample to be collected.

No air particulate sample was collected from Station 21 (Williamstown) for the period of April 3rd to April 15th due to an improperly mounted air filter.

A set of TLDs placed at location GM -29 (Route 8A) was found missing in late June, 2003. Modifications to the mounts to better secure them to existing structures were carried out.

Air particulate sampling station 11 (Observation Stand) and river water sampling station 11 were found shut off on July 15th due to a power outage. Samplers were placed back in service within 21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br />.

4.2 Comparison of Achieved LLDs with Requirements Table 4.3 of the ODCM (Table 2.4 in this report) gives the required Lower Limits of Detection (LLDs) for environmental sample analyses. On occasion, an LLD is not achieved due to situations such as a low sample volume caused by sampling equipment malfunction. In such a case, Control 7.1 of the ODCM requires a discussion of the situation in the Annual Radiological Environmental Operating Report. At the E-LAB, the target LLD for any analysis is typically 30-40 percent of the most restrictive required LLD. Expressed differently, the typical sensitivities achieved for each analysis are at least 2.5 to 3 times better than that required by the YNPS ODCM.

For each analysis having an LLD requirement in ODCM Table 4.3, the a posteriori or after the fact LLD calculated for that analysis was compared with the required LLD. O f the more than 830 analyses performed with a specified LLD requirement in 2003, 100% met the requirements of Table 4.3 of the ODCM in 2003.

4.3 Results Compared Against Reporting Levels ODCM Control 4.1.a. requires the written notification to the NRC within 30 days whenever a Reporting Level in ODCM Table 4.2 is exceeded. Reporting Levels are the environmental concentrations that relate to the ALARA design dose objectives of 10 CFR 50, Appendix I. It should be noted that environmental concentrations are averaged over calendar quarters for the purposes of this comparison, and that Reporting Levels apply only to measured levels of radioactivity due to plant effluents. During 2003, no Reporting Levels were exceeded.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 36 4.4 Data Analysis by Media Type The 2003 REMP data for each media type are discussed below. These are arranged in the same order as in Table 3.1, and are further categorized by pathway. Graphical plots of monitoring data are also shown in Figures 4-1 to 4-11. With respect to data plots, all values are plotted, whether they are "detectable" or "non-detectable."

4.4.1 Air Particulates The biweekly air particulate filters from each of the six operating sampling sites. Five are indicators stations, AP-11, -12, -

13, -14, and -31 in the plant vicinity, and one control station, AP-31in Williamstown, MA. Filters are analyzed for gross-beta radioactivity. At the end of each quarter, the individual filters collected during the quarter from each sampling site were composited for a gamma analysis. The results of the biweekly air-particulate sampling program are shown in Table 3.1 and Figures 4-1 through 4-2.

Figure 4.1 Gross-Beta Measurements on Air Particulate Filters (Quarterly Averages) 0 0.01 0.02 0.03 0.04 0.05 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 pCi/cubic meter 0

0.01 0.02 0.03 0.04 0.05 Control Indicators As shown in Figure 4-1, there has been no significant difference between the concentration at the indicator (near-plant)

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 37 stations and the control (distant from plant) stations.

Figure 4-2 shows the biweekly gross beta concentration at each air particulate sampling location required by the ODCM along with the control air particulate sampling location at AP-21 (Williamstown, MA). It can be seen that the gross-beta measurements on air particulate filters fluctuate significantly over the course of a year. This is due principally to seasonal variations and the related effects on naturally occurring terrestrial radionuclide emissions. The measurements from control station AP-21 vary similarly, indicating that these fluctuations are due to regional changes in naturally-occurring airborne radioactive materials, and not due to YNPS operations. Table 3.1 shows that the mean concentration from indicator stations, on the average, are similar to those from control locations, further supporting this conclusion.

0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05 Jan-03 Jan-03 Mar-03 Apr-03 May-03 May-03 Jun-03 Jul-03 Aug-03 Sep-03 Oct-03 Nov-03 Dec-03 Reference Date of Sample Gross Beta Concentration (pCi/m3)

AP-11 Observation Stand AP-12 Monroe Bridge AP-13 Rowe School AP-14 Harriman Station AP-21 Williamstown, MA AP-31 Furlon House Figure 4-2 Yankee Rowe Bi-Weekly Air Particulate Gross Beta Analysis Results 4.4.2 River Water Aliquots of river water were automatically collected every two hours from the Deerfield River downstream from the plant (WR-11at Bear Swamp Lower Reservoir). These composited samples were collected monthly and sent to the E-LAB for gamma, tritium and gross beta analysis. Monthly grab samples were also collected at the Harriman Reservoir control location and at Sherman Pond near the discharge area (WR-21 and -31, respectively).

Table 3.1 shows that gross-beta measurements were positive in six of the thirty-nine samples collected, as might be expected, due to naturally-occurring radionuclides in the water. The historical concentrations at the indicator and control locations have not been significantly different, as shown in Figure 4-3, except during the last half of 1992, 1998-1999, and in 2002 when the levels at WR-11 were slightly elevated relative to the control, but no tritium or other plant related gamma emitter was detected in either sample set in 2002. This was attributed to naturally-occurring radioactivity as discussed in the earlier Annual Radiological Environmental Operating Reports. For 2003, the indicator station gross beta results

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 38 averaged below the control station values by a small amount, with both the indicator and control station averages in close agreement for the second half averages suggesting no significant difference between the control location and indicator samples in 2003. In addition, no tritium or gamma spectroscopy analyses found detectable levels of plant-related radioactivity in any of the 2003 river water samples.

Figure 4-3 Gross-Beta Measurements of River Water (Semi-Annual Averages) 0 1

2 3

4 5

6 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 pCi/kg 0

1 2

3 4

5 6

WR-11 Bear Swamp Lower Reservoir WR-21 Harriman Reservoir During the fall of 2003 all water was drained from the YNPS Spent Fuel Pool as part of plant decommissioning activities and in accordance with NPDES and effluent ODCM requirements. The water from the fuel pool was treated and released to the Deerfield River. During the release a number of special river water samples were taken to monitor any radiological consequences at Station 91 in Sherman Pond near the release point. These included three samples analyzed for tritium and twenty-eight gamma spectroscopy analyses. None of those samples contained detectable levels of radioactivity.

4.4.3 Ground Water Monthly ground water samples were collected from two on-site locations during 2003, the plant potable water well and Sherman Spring, WG-11 and -12, respectively (only quarterly samples are required by ODCM Table 4.1). Table 3.1 shows that gross-beta measurements were positive in most of the samples. This is due to naturally-occurring radionuclides in

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 39 the water.

Tritium was not detected in any of the samples from either sample location. A steadily decreasing concentration of H-3 has been detected in previous years in WG-12 (Sherman Spring) samples, as shown in Figure 4-4. The water from Sherman Spring leaves the ground on YNPS property and flows into the Deerfield River. Neither the Deerfield River nor Sherman Spring is used for drinking water.

No gamma-emitting radionuclides or plant-related radioactivity were detected in any of the ground water samples.

Figure 4-4 Tritium in Ground Water Station WG-12, Sherman Spring

-800

-300 200 700 1200 1700 1996 1997 1998 1999 2000 2001 2002 2003 pCi/kg 4.4.4 Storm Drain Water Monthly grab samples were collected from the East and West Storm Drains (WW-51 and 52, respectively) when available during 2003. Each sample was analyzed for gross-beta and gamma-emitting radionuclides and H-3. Gross-beta measurements were positive in most of the samples taken, as would be expected. The levels are consistent with those from previous years. Three samples had gross beta results below detectable limits. No gamma-emitting radionuclides or H-3 were detected in any of the samples.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 40 4.4.5 Sediment Semiannual sediment core samples were collected from three locations during 2003. Indicator stations SE-91 and SE-11are located in Sherman Pond and at No. 4 Dam, respectively, and control station SE-21 is located at Harriman Reservoir. Each set of samples was segmented by depth (0-5, 5-10, 10-15 cm) and analyzed for gamma-emitting radionuclides. As would be expected, naturally-occurring K-40 and Th-232 were detected in most of the samples.

In addition to the naturally-occurring radionuclides, Cs -137 was detected in just over 42% of the segments. The result from the 10-15 cm depth segment from downstream location SE-11 (Figure 4-5), while elevated, is consistent with what has been measured in previous years and is bounded by levels previously reported at the control location (SE-21) reported in 1987 and 1995. It is attributed to nuclear weapons testing fallout. The Cs -137 in the 0-5-10 cm and 10-15 cm depth segments at SE-11 are bounded by levels previously reported at the same location.

FIGURE 4-5 CESIUM-137 IN SHORELINE SEDIMENT STATION SE-11

-100.00

-50.00 0.00 50.00 100.00 150.00 200.00 250.00 300.00 350.00 400.00 05/97 10/97 05/98 10/98 05/99 10/99 05/00 10/00 05/01 10/01 05/02 10/02 04/03 10/03 Month/Year pCi/kg (dry) 0-5 cm 5-10 cm 10-15 cm

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 41 Results from the upstream (SE-21) control location are also elevated (Figure 4-6), but also are bounded by levels previously reported at that location. At both the indicator and the control location, the character of the sediment is highly dependent on the specific location sampled, which in turn is dependent on the water level in Harriman Reservoir or on the Deerfield River shoreline at the time of sampling. The diverse character of the sediment at either location and the fact that Cs-137 tends to bind more to finer-grained sediment containing organic matter than to sandy and rocky sediment leads to a wide range of Cs -137 concentrations, as shown in Figures 4-5 through 4-7.

FIGURE 4-6 CESIUM-137 IN SHORELINE SEDIMENT STATION SE-21

-100 100 300 500 700 900 1100 05/97 10/97 05/98 10/98 05/99 10/99 05/00 10/00 05/01 10/01 05/02 10/02 04/03 10/03 Month/Year pCi/kg (dry) 0-5 cm 5-10 cm 10-15 cm

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 42 Table 3.1 and Figure 4-7 show the levels of Cs -137 at station SE-91. These samples were collected from a deep water location near the plant discharge in Sherman Pond. Although much of the Cs -137 in this sediment is due to global nuclear weapons testing fallout, some of the Cs -137 in these samples might be due to effluents released from monitored plant discharges. It is believed that the higher Cs -137 levels at SE-91, whether due to fallout or plant effluents, are related to the physical make-up of the sediment (rich organic benthic layer) at the bottom of Sherman Pond.

FIGURE 4-7 CESIUM-137 IN SHORELINE SEDIMENT STATION SE-91 0

500 1000 1500 2000 2500 3000 3500 4000 05/97 10/97 05/98 10/98 05/99 10/99 05/00 10/00 05/01 10/01 05/02 10/02 04/03 10/03 Month/Year pCi/kg (dry) 0-5 cm 5-10 cm 10-15 cm

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 43 4.4.6 Fish Semiannual samples of fish were collected from two locations during 2003, FH-11, an indicator station, Sherman Reservoir, and FH-21, a control station, Harriman Reservoir. The edible portions of each of these were analyzed for gamma-emitting radionuclides. As expected in biological matter, naturally-occurring K-40 was detected in all samples. No other gamma emitting radionuclides were detected in 2003 fish samples. The average Cs -137 concentrations shown in Figure 4-8 are not considered detectable or "positive" measurements. The wide variation in Cs -137 activity is primarily due to the different species of fish and the specific eating habits of the fish. Fish that are bottom feeders would tend to pick up more of the Cs -

137 activity located in the water sediment. One of four samples taken in 2003 had a detectable level of Cs -137. Although the presence of Cs -137 in this media is historically attributed to residual weapons testing fallout, the Cs -137 in fish is conservatively treated as a possible plant-related nuclide with the dose consequence assessed in Section 5.

FIGURE 4-8 CESIUM-137 IN FISH ANNUAL AVERAGE CONCENTRATIONS 0

10 20 30 40 50 60 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 Year pCi/kg FH-11 Sherman Pond FH-21 Harriman Reservoir (control)

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 44 4.4.7 Food Three food samples were collected from indicator stations TF-11 and -13 in Monroe Bridge and Monroe, MA, respectively, and from a control station, TF-21 in Williamstown, MA during 2003. Samples were analyzed for gamma-emitting radionuclides. K-40 was detected in all three samples. No other gamma emitting radionuclides were detected in 2003 food samples.

4.4.8 Maple Syrup Processed maple syrup samples were collected from an indicator and control location during the month of April 2003. The indicator station is MS-33 in Rowe, MA, and the control station, MS-45, is in Florida, MA. These samples represent concentrated media, relative to the original tree sap, by boiling (see Section 2.5.9). Naturally-occurring K-40 and Cs-137 were detected in both samples. The concentrations of Cs -137 in 2003 samples are consistent with that detected in both indicator and control samples in previous years, and is attributed to global nuclear weapons testing fallout.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 45 4.4.9 Direct Radiation Direct radiation is continuously measured at 33 locations surrounding YNPS with the use of thermoluminescent dosimeters (TLDs). These are collected every calendar quarter for readout at the E-LAB.

As shown in Figure 4-9, there is a distinct annual cycle at both indicator and control locations. The lowest point of the cycle occurs during the winter months. This is due primarily to the attenuating effect of the snow cover on radon emissions and on direct irradiation by naturally-occurring radionuclides in the soil. Differing amounts of these radionuclides in the underlying soil, rock or nearby building materials result in different radiation levels between one field site and another.

Figure 4-9 Exposure Rate at Indicator, Outer Ring and Control TLDs 0

5 10 15 1996 1997 1998 1999 2000 2001 2002 2003 2004 Micro-R per Hour 0

5 10 15 Indicators Control Outer Ring

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 46 From Table 3.2 and 3.3, it can be seen that the mean exposure rates for the Indicator, Outer Ring, and Control categories were not significantly different in 2003. This indicates that there was no significant overall increase in direct radiation exposure rates in the plant vicinity beyond the industrial area of plant structures. As shown in Figures 4-10 and 4-11, the levels at offsite locations in 2003 are consistent with or bounded by levels in previous years.

Figure 4-10 Exposure Rate at Indicator TLDs 0

5 10 15 1996 1997 1998 1999 2000 2001 2002 2003 Micro-R per Hour 0

5 10 15 GM-01 YAEC Visitor's Center GM-02 Observation Stand GM-03 Rowe School GM-04 Harriman Station GM-05 Monroe Bridge GM-06 Readsboro Road Barrier GM-07 Whitingham Line GM-08 Monroe Hill Barrier GM-09 Dunbar Brook GM-10 Cross Road GM-11 Adams High Lane GM-12 Readsboro, VT GM-40 Readsboro Road

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 47 Results from the Fenceline TLDs are shown in Figure 4-11 and summarized in Tables 3.2 and 3.3. These TLDs are located on the fence surrounding the Radiation Control Area within the YNPS property bounds, and are influenced by the ISFSI.

Specifically, the elevated exposure rates at TLD locations GM-18, -19, and -20 during 2003 are due to fuel and GTCC transfer activities to the ISFSI completed during 2003.

Figure 4-11 Exposure Rate at Fenceline TLDs 0

5 10 15 20 25 30 35 40 1996 1997 1998 1999 2000 2001 2002 2003 Micro-R/hour 0

20 40 GM-13 Restricted Area Fence GM-14 Restricted Area Fence GM-15 Restricted Area Fence GM-16 Restricted Area Fence GM-17 Restricted Area Fence GM-18 Restricted Area Fence GM-19 Restricted Area Fence GM-20 Restricted Area Fence GM-21 Restricted Area Fence

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 48 5.0 OFF-SITE DOSE EQUIVALENT COMMITMENTS The purpose of this section is to evaluate off-site dose consequences (dose equivalent commitments) associated with detectable plant related radioactivity in environmental media. The method utilizes Regulatory Guide 1.109 (Reference 2)

ODCM models and actual measurements of the concentrations of radioactivity in various environmental media (e.g., air, sediment, ground water) to compute the dose consequences resulting from the inhalation or ingestion of such material.

These evaluations can be used to provide assurance that the stations radioactive liquid and airborne effluent dose models are unlikely to underestimate actual impacts.

The standards for the maximum dose to an individual of the general public taken from 40 CFR190, is 25 mRem to the whole body, 75 mRem to the thyroid, and 25 mRem to any other organ. These standards are a fraction of the USA background radiation of 300 mRem per year given in NCRP 94 (Reference 3).

During 2003 there were no instances of plant-related radioactivity observed in environmental media with the possible exception of Cs-137 in sediment near the plant discharge structure. Detected levels of radioactivity attributable to natural processes or fallout include gross beta and Be-7 in air particulate samples, and gross beta in water samples, K-40 and Cs-137 in fish, K-40 and Cs-137 and Ac-Th-228 in river sediment.

A detected level of Cs -137 in one of four fish samples is conservatively evaluated. The measured level represents a potential annual dose commitment to a maximum exposed individual of 0.044 mRem (Teen, Liver) has been estimated using conservative assumptions regarding consumption rate and a constant Cs -137 concentration of 57 pCi/kg in fish. This dose is 0.18% of the Standard Dose Limit of 25 mRem.

Since the REMP for 2003 did not indicate plant related radioactivity in off-site media associated directly with human inhalation or ingestion, there is no indication that the plants effluent dose models underestimate the dose impact to members of the public.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 49

6.0 REFERENCES

1.

USNRC Radiological Assessment Branch Technical Position, "An Acceptable Radiological Environmental Monitoring Program," Revision 1, November 1979.

2.

Regulatory Guide 1.109, Calculation Of Annual Doses To Man From Routine Releases Of Reactor Effluents For The Purpose Of Evaluating Compliance With 10 CFR Part 50, Appendix I, Rev. 1, October, 1977.

3.

Exposure of the Population in the United States and Canada from Natural Background Radiation.

NCRP Report No. 94. National Council on Radiation Protection and Measurements, Bethesda, Maryland, 1994.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 A-1 APPENDIX A - LAND USE CENSUS FOR 2003

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 A-2 APPENDIX A - LAND USE CENSUS FOR 2003 A Land Use Census is conducted annually between the dates of June 1 and October 1 to identify the locations of the nearest milk animal, the nearest residence, and the nearest garden of greater than 500 square feet producing fresh leafy vegetables in each of the 16 meteorological sectors within a distance of five miles of the plant.

Immediately following the collection of field data, in compliance with ODCM Control 4.2, a dosimetric analysis is performed to compare the census locations to the "Critical Receptor" identified in the ODCM. This Critical Receptor is the location that is used in the conservative Method I dose calculations found in the ODCM (i.e. the dose calculations done in compliance with ODCM Surveillance Requirement 3.4). If a Census location has a 20% greater potential dose than that of the Critical Receptor, this fact must be announced in the Semiannual Effluent Release Report for that period. A re-evaluation of which location to use as a Critical Receptor would also be done at that time. For the 2003 Census, no such location was identified.

Pursuant to ODCM Control 4.2, a dosimetric analysis is then performed, using site specific meteorological data, to determine which food product census locations would provide the optimal sampling locations. If any location has a 20% greater potential dose commitment than at a currently-sampled location, the new location is added to the routine environmental sampling program in replacement of the location with the lowest calculated dose (which is later eliminated from the program). For the 2003 Census, no such garden location was identified, and consequently no changes were mandated for the food product sampling program. Also, there were no milk animal locations that could provide milk samples for the REMP identified in the 2003 census.

The Land Use Census was carried out and completed between the dates of June 1 and October 1, as required. The results of the 2003 Land Use Census are included in this report in compliance with ODCM Surveillance Requirement 4.2. The locations identified during the Census may be found in Table A.1.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 A-3 TABLE A.1 2003 LAND USE CENSUS LOCATIONS SECTOR NEAREST RESIDENCE Km (Mi)

NEAREST GARDEN Km (Mi)

NEAREST MILK ANIMAL Km (Mi)

N 5.2 (3.2) 6.0 (3.7)

NNE 4.3 (2.7) 4.8 (3.0)

NE 3.4 (2.1) 3.5 (2.2)

ENE 3.7 (2.3) 5.8 (3.6)

E 2.8 (1.8) 3.4 (2.3)

ESE 3.4 (2.1) 3.4 (2.1)

SE 2.0 (1.3) 3.3 (2.1)

SSE 1.9 (1.2) 1.9 (1.2)

S 2.1 (1.3) 2.8 (1.8)

SSW SW 1.3 (0.8) 7.2 (4.5)

WSW 1.3 (0.8) 1.9 (1.2)

W 2.0 (1.3) 2.9 (1.8)

WNW 2.0 (1.3) 1.9 (1.2)

NW 2.4 (1.5) 2.8 (2.0)

NNW 2.9 (1.8) 3.7 (2.3)

  • No location was identified within 5 miles of the plant.

APPENDIX B - QUALITY ASSURANCE PROGRAM

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-2 Appendix B: QUALITY ASSURANCE PROGRAM The quality assurance program at the AREVA Framatome ANP Environmental Laboratory (E-LAB) is designed to serve two overall purposes: 1) Establish a measure of confidence in the measurement process to assure the licensee, regulatory agencies and the public that analytical results are accurate and precise; and 2) Identify deficiencies in the sampling and/or measurement process to those responsible for these operations so that corrective action can be taken. Quality assurance is applied to all steps of the measurement process, including the collection, measurement and reporting of data, as well as the record keeping of the final results. Quality control, as part of the quality assurance program, provides a means to control and measure the characteristics of the measurement equipment and processes, relative to established requirements.

The E-LAB employs a comprehensive quality assurance program designed to monitor the quality of analytical processing to ensure reliable environmental monitoring data. The program includes the use of controlled procedures for all work activities, a nonconformance and corrective action tracking system, systematic internal audits, audits by external groups, a laboratory quality control program, and a staff training program. Monitoring programs include the Intralaboratory Quality Control Program administered by the Laboratory QA Officer (used in conjunction with the National Institute of Standards and Technology Measurement Assurance Program, NIST MAP) and a third party cross check program administered by Analytics, Inc. Together these programs are targeted to supply QC/QA sources at 5% of the client sample analysis load. In addition a blind duplicate program is conducted through client environmental monitoring programs.

This summary reports all intralaboratory and third party results received by E-LAB on or before December 31, 2003.

Intralaboratory Quality Control Program The E-LAB QA Officer administers an extensive intralaboratory quality control program in which process check samples are submitted for analysis. These samples are spiked with a known amount of radioactive material and are routinely submitted in triplicate to evaluate the bias and precision of a measurement process. Table B.1 provides the summary of the process check results for January to December 2003. Of the 407 analyses, 98.0% passed the bias criteria and 100% of the 135 results evaluated for precision were acceptable. The E-LAB internal acceptance criteria are summarized at the end of Table B.1.

Third Party Cross Check Program The E-LAB participates in a third party cross check program managed by Analytics Inc. to satisfy the requirement of the Environmental Technical Specification/ODCM. The E-LAB Analytics program was originally used to augment the EPA Intercomparison Program that it now replaces. The current program is designed to be comparable to the pre-1996 EPA PE Program in terms of the number of samples, matrices and nuclides. The results for the 4th quarter 2002 through the 3rd quarter 2003 are summarized in Table B.2. Each sample is normally analyzed in triplicate and the results are evaluated against the internal acceptance criteria described in the E-LAB Manual 100-Laboratory Quality Assurance Plan. This acceptance protocol is used for all inter-laboratory programs with no pre-set acceptance criteria. When results fall outside of the acceptance criteria, an investigation is initiated to determine the cause of the problem and if appropriate, corrective measures are taken. The E-LAB internal acceptance criteria are summarized at the end of Table B.1.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-3 Blind Duplicate Program Under the Blind Duplicate Quality Assurance Program, samples are split from homogeneous environmental media by the client and sent to the E-LAB for analysis. They are "blind" in that the identification of the matching sample is not identified to the Laboratory.

Participating clients submitted a total of 18 paired samples in 2003. The measurements evaluated include twenty-six gamma emitting radionuclides, H-3, and gross-beta. All measurements are evaluated, whether the results are statistically positive or not, and whether the net concentration is positive or negative.

The samples submitted as part of this program are listed in Table B.3. For the 2003 program, 99.6% (482/484) of the measurements met the E-LAB internal acceptance criteria.

Environmental TLD Quality Assurance Program Performance documentation of the routine processing of the Panasonic environmental TLDs (thermoluminescent dosimeter) program at the E-LAB is provided by the dosimetry quality assurance testing program. This program includes independent third party performance testing by Battelle Pacific Northwest Labs and internal performance testing conducted by the Laboratory QA Officer. Under these programs, sets of six dosimeters are irradiated to ANSI specified testing criteria and submitted for processing to the Dosimetry Services Section as unknowns. The bias and precision of TLD processing is measured against this standard and is used to indicate trends and changes in performance. Instrumentation checks, although routinely performed by the Dosimetry Services Group and representing between 5-10% of the TLDs processed, are not presented in this report because they do not represent a true process check sample since the exposures are known to the processor.

Ninety performance tests were conducted in 2003 by E-LAB and the third party tester. These tests were made on 15 separate sets of 6 dosimeters. All of the 15 TLD test sets passed the mean bias criteria of +/-20.1%. Of the ninety individual measurements, 100% of the dosimeter evaluations met the E-LAB Internal Acceptance Criteria for bias (+/-20.1%) and precision (+/-12.8%). Third Party QC results are summarized below.

Percentage of Individual Analyses that passed E-LAB Internal Criteria Dosimeter Type Number Tested

% Passed Bias Criteria

% Passed Precision Criteria Panasonic Environmental 90 100 100 Summary of Third Party Testing Dosimeter Type Exposure Period ANSI Category

% (Bias +/- SD)

Panasonic Environmental Q4/2002 II, high energy 4.2 +/- 1.2 Q1/2003 II, high energy 6.1 +/- 8.6 Q2/2003 II, high energy 1.8 +/- 1.4 Q3/2003 II, high energy 3.2 +/- 0.9

  • American National Standards Institute (ANSI) Performance Statistic as referenced in the Dosimetry Services Semi-Annual QA Status Report.

Note: Results are expressed as the delivered exposure for environmental TLD. ANSI HPS N13.29-1995 (Draft) Category II, High energy

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-4 photons (Cs-137 or Co-60).

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-5 TABLE B.1 E-LAB RESULTS IN THE INTRALABORATORY PROCESS CONTROL PROGRAM January - December 2003 Bias Criteria (1)

Precision Criteria (2)

Media Analysis 1

2 3

4 1

2 3

4 I. Air Charcoal Gamma 22 2

0 0

0 0

0 0

II. Air Filter Alpha Beta 206 10 0

1 0

0 0

0 Gamma III. Milk Gamma Iodine-LL 9

1 0

0 10 0

0 0

Strontium-89 0

4 1

0 3

1 1

0 Strontium-90 0

2 3

0 1

4 0

0 IV. Water Gross Alpha 7

12 14 4

2 0

8 0

Gross Beta 34 12 2

0 8

2 4

0 Gamma 14 0

0 0

0 2

22 0

Iodine-LL 5

0 0

0 5

0 0

0 Sr-90 2

2 1

0 0

0 6

0 Tritium 21 5

1 0

26 6

12 0

V. Sediment/Soil Gamma 2

0 0

0 0

0 0

0 Pu-238 1

0 0

0 4

0 0

0 Pu-239 0

1 1

1 4

0 0

0 Am-241 2

0 0

2 0

4 0

1 Total Number in Range 325 51 23 8

63 19 53 0

Percentage of Total Processed 79.9 12.5 5.7 2.0 46.7 14.1 39.3 0.0 Sum of Analyses 407 135 (1) Percent Bias Criteria by Bias Category (2) Percent Precision Criteria by Precision Category Bias Category = 1 > 0% and < = 5%

Precision Category = 1 > 0% and < = 5%

Bias Category = 2 > 5% and < = 10%

Precision Category = 2 > 5% and < = 10%

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-6 Bias Category = 3 > 10% and < = 15%, or Precision Category = 3 > 10% and < = 15%, or within 2 sigma of known within 2 sigma of mean Gross alpha/beta water, Sr 89/90 > 10% and < = 25%

Precision Category = 4 Outside Criteria Transuranics > 10% and < = 20%

Bias Category = 4 Outside Criteria TABLE B.2 E-LAB RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2002 - Quarter 3, 2003 Ratio Sample Quarter/

Sample Reported Known E-LAB/

Number Year Media Nuclide Value Value Analytics Evaluation E3461-162 4th/2002 Water H-3 5450 5987 0.91 Agreement E3462-162 4th/2002 Water Sr-89 72 79 0.91 Agreement 4th/2002 Sr-90 16 16 1.00 Agreement E3463-162 4th/2002 Filter Gross Alpha 52 59 0.88 Agreement 4th/2002 Gross Beta 147 150 0.98 Agreement E3464-162 4th/2002 Filter Ce-141 59 59 1.00 Agreement 4th/2002 Cr-51 184 184 1.00 Agreement 4th/2002 Cs-134 51 53 0.96 Agreement 4th/2002 Cs-137 125 117 1.07 Agreement 4th/2002 Co-58 75 74 1.01 Agreement 4th/2002 Mn-54 83 75 1.11 Agreement 4th/2002 Fe-59 43 38 1.13 Agreement 4th/2002 Zn-65 103 95 1.08 Agreement 4th/2002 Co-60 84 87 0.97 Agreement E3465-162 4th/2002 Filter Sr-89 68 75 0.91 Agreement 4th/2002 Sr-90 61 60 1.02 Agreement E3466-162 4th/2002 Milk I-131LL 89.2 86 1.04 Agreement 4th/2002 I-131 81 86 0.94 Agreement 4th/2002 Ce-141 103 111 0.91 Agreement 4th/2002 Cr-51 334 346 0.97 Agreement 4th/2002 Cs-134 98 99 0.90 Agreement 4th/2002 Cs-137 220 220 1.00 Agreement 4th/2002 Co-58 134 139 0.96 Agreement 4th/2002 Mn-54 142 142 1.00 Agreement 4th/2002 Fe-59 74 72 1.03 Agreement 4th/2002 Zn-65 177 178 0.99 Agreement 4th/2002 Co-60 162 164 0.99 Agreement E3597-162 1st/2003 Water Gross Alpha 55 61 0.90 Agreement 1st/2003 Gross Beta 146 186 0.78 Agreement E3598-162 1st/2003 Water I-131LL 67.7 70 0.97 Agreement 1st/2003 I-131 68 70 0.97 Agreement 1st/2003 Ce-141 163 168 0.97 Agreement 1st/2003 Cr-51 243 238 1.02 Agreement

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-7 1st/2003 Cs-134 83 88 0.94 Agreement 1st/2003 Cs-137 188 195 0.96 Agreement 1st/2003 Co-58 44 42 1.05 Agreement 1st/2003 Mn-54 61 63 0.97 Agreement

  • pCi/Liter (Filters in pCi)

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-8 TABLE B.2 (contd)

E-LAB RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2002 - Quarter 3, 2003 Ratio Sample Quarter/

Sample Reported Known E-LAB/

Number Year Media Nuclide Value Value Analytics Evaluation E3598-162 1st/2003 Water Fe-59 48 46 1.04 Agreement 1st/2003 Zn-65 88 90 0.98 Agreement 1st/2003 Co-60 156 157 0.99 Agreement E3599-162 1st/2003 Filter Gross Alpha 52 49 1.06 Agreement 1st/2003 Gross Beta 157 148 1.06 Agreement E3600-162 1st/2003 Milk I-131LL 72.5 74 0.98 Agreement 1st/2003 I-131 73 74 0.99 Agreement 1st/2003 Ce-141 170 173 0.98 Agreement 1st/2003 Cr-51 244 246 0.99 Agreement 1st/2003 Cs-134 86 90 0.96 Agreement 1st/2003 Cs-137 196 200 0.98 Agreement 1st/2003 Co-58 44 47 0.94 Agreement 1st/2003 Mn-54 61 64 0.95 Agreement 1st/2003 Fe-59 47 47 1.00 Agreement 1st/2003 Zn-65 96 93 1.03 Agreement 1st/2003 Co-60 162 162 1.00 Agreement E3601-162 1st/2003 Milk Sr-89 121 133 0.91 Agreement 1st/2003 Sr-90 13 12 1.08 Agreement E3608-162 1st/2003 Water Sr-89 104 114 0.91 Agreement 1st/2003 Sr-90 11 10 1.10 Agreement E3704-162 2nd/2003 Water H-3 10643 11953 0.89 Agreement E3705-162 2nd/2003 Filter Gross Alpha 20 21 0.95 Agreement 2nd/2003 Gross Beta 116 115 1.01 Agreement E3706-162 2nd/2003 Filter Ce-141 149 154 0.97 Agreement 2nd/2003 Cr-51 134 130 1.03 Agreement 2nd/2003 Cs-134 54 56 0.96 Agreement 2nd/2003 Cs-137 135 125 1.08 Agreement 2nd/2003 Co-58 53 50 1.06 Agreement 2nd/2003 Mn-54 110 101 1.09 Agreement 2nd/2003 Fe-59 60 54 1.11 Agreement 2nd/2003 Zn-65 110 99 1.11 Agreement 2nd/2003 Co-60 71 72 0.99 Agreement E3707-162 2nd/2003 Filter Sr-89 78 87 0.90 Agreement 2nd/2003 Sr-90 24 24 1.00 Agreement E3708-162 2nd/2003 Milk I-131 109 103 1.06 Agreement 2nd/2003 I-131LL 104 103 1.01 Agreement 2nd/2003 Ce-141 283 283 1.00 Agreement 2nd/2003 Cr-51 239 239 1.00 Agreement

  • pCi/Liter (Filters in pCi)

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-9 TABLE B.2 (contd)

E-LAB RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2002 - Quarter 3, 2003 Ratio Sample Quarter/

Sample Reported Known E-LAB/

Number Year Media Nuclide Value Value Analytics Evaluation E3708-162 2nd/2003 Milk Cs-134 98 103 0.95 Agreement 2nd/2003 Cs-137 232 230 1.01 Agreement 2nd/2003 Co-58 92 93 0.99 Agreement 2nd/2003 Mn-54 186 186 1.00 Agreement 2nd/2003 Fe-59 100 99 1.01 Agreement 2nd/2003 Zn-65 181 181 1.00 Agreement 2nd/2003 Co-60 134 132 1.02 Agreement E3866-162 3rd/2003 Water Gross Alpha 37 36 1.03 Agreement 3rd/2003 Gross Beta 242 246 0.98 Agreement E3867-162 3rd/2003 Water I-131 69 76 0.91 Agreement 3rd/2003 I-131LL 78 76 1.03 Agreement 3rd/2003 Ce-141 78 81 0.96 Agreement 3rd/2003 Cr-51 198 221 0.90 Agreement 3rd/2003 Cs-134 108 113 0.96 Agreement 3rd/2003 Cs-137 85 84 1.01 Agreement 3rd/2003 Co-58 92 94 0.98 Agreement 3rd/2003 Mn-54 93 88 1.06 Agreement 3rd/2003 Fe-59 74 75 0.99 Agreement 3rd/2003 Zn-65 170 166 1.02 Agreement 3rd/2003 Co-60 118 117 1.01 Agreement E3868-162 3rd/2003 Filter Gross Alpha 30 28 1.07 Agreement 3rd/2003 Gross Beta 197 189 1.04 Agreement E3869-162 3rd/2003 Milk I-131 66 74 0.89 Agreement 3rd/2003 I-131LL 74 74 1.00 Agreement 3rd/2003 Ce-141 90 86 1.03 Agreement 3rd/2003 Cr-51 228 233 0.98 Agreement 3rd/2003 Cs-134 123 119 1.03 Agreement 3rd/2003 Cs-137 94 88 1.07 Agreement 3rd/2003 Co-58 99 99 1.00 Agreement 3rd/2003 Mn-54 101 93 1.09 Agreement 3rd/2003 Fe-59 84 79 1.06 Agreement 3rd/2003 Zn-65 178 176 1.01 Agreement 3rd/2003 Co-60 129 123 1.05 Agreement E3870-162 3rd/2003 Milk Sr-89 80 100 0.80 Agreement 3rd/2003 Sr-90 11 14 0.79 Agreement

  • pCi/Liter (Filters in pCi)

Bias and Precision Acceptance Criteria as described above.

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003 B-10 TABLE B.3

SUMMARY

OF BLIND DUPLICATE SAMPLES January - December 2003 TYPE OF SAMPLE NUMBER OF PAIRED SAMPLES SUBMITTED Ground Water 2

Surface Water 12 Algae 2

Mussels 2

TOTAL 18

C-1 APPENDIX C -

SUMMARY

OF 2003 REMP DATA

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-2 Yankee Nuclear Power Station Radiological Environmental Monitoring Program Air Particulates Summary of 2003 Data SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 11 L4689-01 1/15/2003 GR-B 1.54E-02 6.80E-04 1.40E-03 AP 11 L4764-01 1/29/2003 GR-B 2.22E-02 8.50E-04 1.70E-03 AP 11 L4870-01 2/11/2003 GR-B 2.40E-02 8.80E-04 1.40E-03 AP 11 L4956-01 2/25/2003 GR-B 1.45E-02 6.00E-04 1.30E-03 AP 11 L5030-01 3/11/2003 GR-B 2.65E-02 8.90E-04 1.50E-03 AP 11 L5145-01 3/25/2003 GR-B 1.99E-02 7.80E-04 1.30E-03 AP 11 L5200-01 4/2/2003 GR-B 1.85E-02 9.50E-04 2.20E-03 AP 11 L5280-01 4/15/2003 GR-B 1.82E-02 8.40E-04 1.70E-03 AP 11 L5369-01 4/29/2003 GR-B 2.01E-02 7.50E-04 1.40E-03 AP 11 L5457-01 5/13/2003 GR-B 1.09E-02 6.30E-04 1.40E-03 AP 11 L5521-01 5/27/2003 GR-B 9.95E-03 5.80E-04 1.20E-03 AP 11 L5601-01 6/10/2003 GR-B 1.36E-02 6.60E-04 1.30E-03 AP 11 L5709-01 6/24/2003 GR-B 1.07E-02 6.00E-04 1.20E-03 AP 11 L5721-01 6/30/2003 GR-B 2.94E-02 1.60E-03 3.40E-03 AP 11 L5792-01 7/15/2003 GR-B 1.86E-02 7.30E-04 1.30E-03 AP 11 L5909-01 7/29/2003 GR-B 1.77E-02 7.60E-04 1.40E-03 AP 11 L5961-01 8/12/2003 GR-B 1.40E-02 6.70E-04 1.30E-03 AP 11 L6029-01 8/25/2003 GR-B 2.06E-02 8.50E-04 1.60E-03 AP 11 L6103-01 9/9/2003 GR-B 1.86E-02 7.20E-04 1.40E-03 AP 11 L6211-01 9/23/2003 GR-B 1.88E-02 7.50E-04 1.40E-03 AP 11 L6252-01 9/30/2003 GR-B 2.11E-02 1.20E-03 2.60E-03 AP 11 L6315-01 10/13/2003 GR-B 2.75E-02 8.70E-04 1.30E-03 AP 11 L6436-01 10/29/2003 GR-B 1.46E-02 6.00E-04 1.10E-03 AP 11 L6499-01 11/13/2003 GR-B 2.63E-02 8.70E-04 1.30E-03 AP 11 L6629-01 12/9/2003 GR-B 1.72E-02 7.80E-04 1.40E-03 AP 11 L6703-01 12/26/2003 GR-B 1.58E-02 6.00E-04 1.10E-03 AP 12 L4689-02 1/15/2003 GR-B 2.80E-02 1.40E-03 3.10E-03 AP 12 L4764-02 1/29/2003 GR-B 3.68E-02 1.70E-03 3.60E-03 AP 12 L4870-02 2/11/2003 GR-B 3.22E-02 1.60E-03 3.10E-03 AP 12 L4956-02 2/25/2003 GR-B 2.16E-02 1.20E-03 2.80E-03 AP 12 L5030-02 3/11/2003 GR-B 3.35E-02 1.60E-03 3.30E-03 AP 12 L5145-02 3/25/2003 GR-B 2.70E-02 1.40E-03 2.80E-03 AP 12 L5200-02 4/2/2003 GR-B 2.29E-02 1.80E-03 4.80E-03 AP 12 L5280-02 4/15/2003 GR-B 1.31E-02 6.80E-04 1.50E-03 AP 12 L5369-02 4/29/2003 GR-B 1.96E-02 7.70E-04 1.40E-03 AP 12 L5457-02 5/13/2003 GR-B 1.24E-02 6.50E-04 1.40E-03 AP 12 L5521-02 5/27/2003 GR-B 1.04E-02 5.80E-04 1.20E-03 AP 12 L5601-02 6/10/2003 GR-B 1.38E-02 6.50E-04 1.30E-03 AP 12 L5709-02 6/24/2003 GR-B 1.13E-02 6.10E-04 1.20E-03 AP 12 L5721-02 6/30/2003 GR-B 2.78E-02 1.50E-03 3.30E-03 AP 12 L5792-02 7/15/2003 GR-B 1.85E-02 7.00E-04 1.20E-03 AP 12 L5909-02 7/29/2003 GR-B 1.73E-02 7.00E-04 1.30E-03 AP 12 L5961-02 8/12/2003 GR-B 1.30E-02 6.40E-04 1.30E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-3 Air Particulates SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 12 L6029-02 8/25/2003 GR-B 2.07E-02 8.50E-04 1.60E-03 AP 12 L6103-02 9/9/2003 GR-B 1.88E-02 7.10E-04 1.30E-03 AP 12 L6211-02 9/23/2003 GR-B 1.88E-02 7.40E-04 1.40E-03 AP 12 L6252-02 9/30/2003 GR-B 2.09E-02 1.20E-03 2.60E-03 AP 12 L6315-02 10/13/2003 GR-B 2.66E-02 8.40E-04 1.20E-03 AP 12 L6436-02 10/29/2003 GR-B 1.36E-02 5.80E-04 1.10E-03 AP 12 L6499-02 11/13/2003 GR-B 1.99E-02 6.90E-04 1.00E-03 AP 12 L6629-02 12/9/2003 GR-B 1.65E-02 7.50E-04 1.40E-03 AP 12 L6703-02 12/26/2003 GR-B 1.39E-02 5.70E-04 1.10E-03 AP 13 L4689-03 1/15/2003 GR-B 2.12E-02 1.90E-03 4.90E-03 AP 13 L4764-03 1/29/2003 GR-B 2.63E-02 2.10E-03 5.50E-03 AP 13 L4870-03 2/11/2003 GR-B 3.39E-02 2.30E-03 4.90E-03 AP 13 L4956-03 2/25/2003 GR-B 2.13E-02 1.70E-03 4.50E-03 AP 13 L5030-03 3/11/2003 GR-B 3.95E-02 2.40E-03 5.30E-03 AP 13 L5145-03 3/25/2003 GR-B 3.17E-02 2.10E-03 4.50E-03 AP 13 L5200-03 4/2/2003 GR-B 2.73E-02 2.80E-03 7.70E-03 AP 13 L5280-03 4/15/2003 GR-B 1.99E-02 7.90E-04 1.50E-03 AP 13 L5369-03 4/29/2003 GR-B 2.09E-02 7.80E-04 1.40E-03 AP 13 L5457-03 5/13/2003 GR-B 1.15E-02 6.30E-04 1.40E-03 AP 13 L5521-03 5/27/2003 GR-B 9.72E-03 5.70E-04 1.20E-03 AP 13 L5601-03 6/10/2003 GR-B 1.34E-02 6.50E-04 1.30E-03 AP 13 L5709-03 6/24/2003 GR-B 9.61E-03 5.80E-04 1.20E-03 AP 13 L5721-03 6/30/2003 GR-B 2.61E-02 1.50E-03 3.40E-03 AP 13 L5792-03 7/15/2003 GR-B 1.77E-02 7.10E-04 1.30E-03 AP 13 L5909-03 7/29/2003 GR-B 1.99E-02 7.90E-04 1.50E-03 AP 13 L5961-03 8/12/2003 GR-B 1.67E-02 7.90E-04 1.60E-03 AP 13 L6029-03 8/25/2003 GR-B 2.83E-02 1.10E-03 2.00E-03 AP 13 L6103-03 9/9/2003 GR-B 2.65E-02 1.00E-03 1.90E-03 AP 13 L6211-03 9/23/2003 GR-B 2.32E-02 1.00E-03 2.00E-03 AP 13 L6252-03 9/30/2003 GR-B 3.17E-02 1.80E-03 3.80E-03 AP 13 L6315-03 10/13/2003 GR-B 3.71E-02 1.20E-03 1.80E-03 AP 13 L6436-03 10/29/2003 GR-B 2.11E-02 8.50E-04 1.60E-03 AP 13 L6499-03 11/13/2003 GR-B 2.85E-02 9.80E-04 1.50E-03 AP 13 L6629-03 12/9/2003 GR-B 2.43E-02 1.10E-03 2.00E-03 AP 13 L6703-03 12/26/2003 GR-B 1.64E-02 7.50E-04 1.50E-03 AP 14 L4689-04 1/15/2003 GR-B 1.95E-02 1.00E-03 2.30E-03 AP 14 L4764-04 1/29/2003 GR-B 2.55E-02 1.30E-03 2.80E-03 AP 14 L4870-04 2/11/2003 GR-B 2.77E-02 1.30E-03 2.40E-03 AP 14 L4956-04 2/25/2003 GR-B 1.98E-02 9.50E-04 2.20E-03 AP 14 L5030-04 3/11/2003 GR-B 3.19E-02 1.30E-03 2.60E-03 AP 14 L5145-04 3/25/2003 GR-B 2.44E-02 1.20E-03 2.20E-03 AP 14 L5200-04 4/2/2003 GR-B 2.47E-02 1.50E-03 3.70E-03 AP 14 L5280-04 4/15/2003 GR-B 1.76E-02 1.20E-03 3.00E-03 AP 14 L5369-04 4/29/2003 GR-B 1.80E-02 7.10E-04 1.30E-03 AP 14 L5457-04 5/13/2003 GR-B 1.04E-02 5.90E-04 1.30E-03 AP 14 L5521-04 5/27/2003 GR-B 8.77E-03 5.30E-04 1.20E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-4 SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 14 L5601-04 6/10/2003 GR-B 1.06E-02 5.80E-04 1.20E-03 AP 14 L5709-04 6/24/2003 GR-B 9.48E-03 5.50E-04 1.20E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-5 Air Particulates SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 14 L5721-04 6/30/2003 GR-B 2.43E-02 1.40E-03 3.30E-03 AP 14 L5792-04 7/15/2003 GR-B 1.80E-02 6.70E-04 1.20E-03 AP 14 L5909-04 7/29/2003 GR-B 1.76E-02 7.00E-04 1.30E-03 AP 14 L5961-04 8/12/2003 GR-B 1.35E-02 6.30E-04 1.20E-03 AP 14 L6029-04 8/25/2003 GR-B 1.74E-02 7.40E-04 1.50E-03 AP 14 L6103-04 9/9/2003 GR-B 1.90E-02 7.10E-04 1.30E-03 AP 14 L6211-04 9/23/2003 GR-B 1.79E-02 7.10E-04 1.40E-03 AP 14 L6252-04 9/30/2003 GR-B 2.04E-02 1.10E-03 2.50E-03 AP 14 L6315-04 10/13/2003 GR-B 2.80E-02 8.50E-04 1.20E-03 AP 14 L6436-04 10/29/2003 GR-B 1.43E-02 5.80E-04 1.10E-03 AP 14 L6499-04 11/13/2003 GR-B 2.07E-02 6.90E-04 1.00E-03 AP 14 L6629-04 12/9/2003 GR-B 1.80E-02 7.80E-04 1.40E-03 AP 14 L6703-04 12/26/2003 GR-B 1.56E-02 5.80E-04 1.10E-03 AP 21 L4689-05 1/15/2003 GR-B 4.36E-02 4.60E-03 1.20E-02 AP 21 L4764-05 1/29/2003 GR-B 1.92E-02 1.10E-03 2.40E-03 AP 21 L4870-05 2/11/2003 GR-B 1.18E-02 8.00E-04 1.80E-03 AP 21 L4956-05 2/25/2003 GR-B 1.20E-02 6.70E-04 1.60E-03 AP 21 L5030-05 3/11/2003 GR-B 2.44E-02 9.90E-04 1.90E-03 AP 21 L5145-05 3/25/2003 GR-B 9.73E-03 7.30E-04 1.60E-03 AP 21 L5200-05 4/2/2003 GR-B 1.92E-02 1.10E-03 2.60E-03 AP 21 L5369-05 4/29/2003 GR-B 2.07E-02 8.10E-04 1.50E-03 AP 21 L5457-05 5/13/2003 GR-B 1.46E-02 7.20E-04 1.50E-03 AP 21 L5521-05 5/27/2003 GR-B 1.24E-02 6.40E-04 1.30E-03 AP 21 L5601-05 6/10/2003 GR-B 1.49E-02 6.90E-04 1.40E-03 AP 21 L5709-05 6/24/2003 GR-B 1.14E-02 6.30E-04 1.30E-03 AP 21 L5721-05 6/30/2003 GR-B 3.18E-02 1.60E-03 3.60E-03 AP 21 L5792-05 7/15/2003 GR-B 2.22E-02 7.80E-04 1.40E-03 AP 21 L5909-05 7/29/2003 GR-B 1.93E-02 7.70E-04 1.40E-03 AP 21 L5961-05 8/12/2003 GR-B 1.57E-02 6.90E-04 1.30E-03 AP 21 L6029-05 8/25/2003 GR-B 2.38E-02 9.30E-04 1.70E-03 AP 21 L6103-05 9/9/2003 GR-B 2.06E-02 7.60E-04 1.40E-03 AP 21 L6211-05 9/23/2003 GR-B 1.89E-02 7.50E-04 1.40E-03 AP 21 L6252-05 9/30/2003 GR-B 2.27E-02 1.20E-03 2.60E-03 AP 21 L6315-05 10/13/2003 GR-B 2.65E-02 8.90E-04 1.40E-03 AP 21 L6436-05 10/29/2003 GR-B 1.62E-02 6.60E-04 1.20E-03 AP 21 L6499-05 11/13/2003 GR-B 2.30E-02 7.60E-04 1.10E-03 AP 21 L6629-05 12/9/2003 GR-B 1.28E-02 7.10E-04 1.50E-03 AP 21 L6703-05 12/26/2003 GR-B 1.11E-02 5.70E-04 1.20E-03 AP 31 L4689-06 1/15/2003 GR-B 2.08E-02 1.40E-03 3.40E-03 AP 31 L4764-06 1/29/2003 GR-B 2.44E-02 1.60E-03 4.00E-03 AP 31 L4870-06 2/11/2003 GR-B 2.95E-02 1.70E-03 3.50E-03 AP 31 L4956-06 2/25/2003 GR-B 1.18E-02 1.10E-03 3.00E-03 AP 31 L5030-06 3/11/2003 GR-B 2.58E-02 1.60E-03 3.70E-03 AP 31 L5145-06 3/25/2003 GR-B 1.62E-02 1.30E-03 3.10E-03 AP 31 L5200-06 4/2/2003 GR-B 1.91E-02 1.90E-03 5.30E-03 AP 31 L5280-06 4/15/2003 GR-B 1.66E-02 7.50E-04 1.60E-03 AP 31 L5369-06 4/29/2003 GR-B 1.92E-02 7.80E-04 1.50E-03 AP 31 L5457-06 5/13/2003 GR-B 1.21E-02 6.70E-04 1.50E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-6 Air Particulates SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 31 L5521-06 5/27/2003 GR-B 9.30E-03 5.70E-04 1.30E-03 AP 31 L5601-06 6/10/2003 GR-B 1.28E-02 6.40E-04 1.30E-03 AP 31 L5709-06 6/24/2003 GR-B 1.12E-02 6.20E-04 1.30E-03 AP 31 L5721-06 6/30/2003 GR-B 2.78E-02 1.50E-03 3.40E-03 AP 31 L5792-06 7/15/2003 GR-B 2.02E-02 7.30E-04 1.30E-03 AP 31 L5909-06 7/29/2003 GR-B 1.79E-02 7.40E-04 1.40E-03 AP 31 L5961-06 8/12/2003 GR-B 1.36E-02 6.90E-04 1.40E-03 AP 31 L6029-06 8/25/2003 GR-B 2.05E-02 9.20E-04 1.80E-03 AP 31 L6103-06 9/9/2003 GR-B 1.96E-02 8.30E-04 1.60E-03 AP 31 L6211-06 9/23/2003 GR-B 2.08E-02 8.40E-04 1.60E-03 AP 31 L6252-06 9/30/2003 GR-B 2.50E-02 1.40E-03 3.00E-03 AP 31 L6315-06 10/13/2003 GR-B 3.30E-02 1.00E-03 1.40E-03 AP 31 L6436-06 10/29/2003 GR-B 1.62E-02 6.90E-04 1.30E-03 AP 31 L6499-06 11/13/2003 GR-B 2.56E-02 8.50E-04 1.30E-03 AP 31 L6629-06 12/9/2003 GR-B 2.01E-02 9.30E-04 1.70E-03 AP 31 L6703-06 12/26/2003 GR-B 1.39E-02 6.70E-04 1.40E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-7 Air Particulates SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 11 L5303-01 4/2/2003 AcTh-228

-6.70E-04 8.50E-04 3.90E-03 AP 11 L5303-01 4/2/2003 Be-7 7.10E-02 1.10E-02 2.20E-02 AP 11 L5303-01 4/2/2003 Co-58 1.60E-04 2.60E-04 1.10E-03 AP 11 L5303-01 4/2/2003 Co-60

-1.60E-04 3.00E-04 1.40E-03 AP 11 L5303-01 4/2/2003 Cs-134 2.70E-04 2.20E-04 7.30E-04 AP 11 L5303-01 4/2/2003 Cs-137 5.00E-05 2.50E-04 9.80E-04 AP 11 L5303-01 4/2/2003 K-40 4.60E-03 3.50E-03 1.20E-02 AP 11 L5840-01 6/30/2003 AcTh-228 2.00E-04 1.10E-03 4.40E-03 AP 11 L5840-01 6/30/2003 Be-7 1.06E-01 1.40E-02 2.80E-02 AP 11 L5840-01 6/30/2003 Co-58 9.00E-05 5.90E-04 2.40E-03 AP 11 L5840-01 6/30/2003 Co-60 3.40E-04 4.20E-04 1.60E-03 AP 11 L5840-01 6/30/2003 Cs-134

-1.90E-04 3.80E-04 1.60E-03 AP 11 L5840-01 6/30/2003 Cs-137

-4.10E-04 5.50E-04 2.10E-03 AP 11 L5840-01 6/30/2003 K-40 3.20E-03 4.30E-03 1.60E-02 AP 11 L6329-01 9/30/2003 AcTh-228

-4.60E-04 9.70E-04 4.30E-03 AP 11 L6329-01 9/30/2003 Be-7 9.10E-02 1.10E-02 2.20E-02 AP 11 L6329-01 9/30/2003 Co-58

-5.60E-04 4.90E-04 2.30E-03 AP 11 L6329-01 9/30/2003 Co-60 3.00E-05 3.80E-04 1.60E-03 AP 11 L6329-01 9/30/2003 Cs-134 6.60E-04 3.30E-04 9.70E-04 AP 11 L6329-01 9/30/2003 Cs-137 8.00E-04 6.10E-04 2.00E-03 AP 11 L6329-01 9/30/2003 K-40

-3.00E-04 4.30E-03 1.80E-02 AP 11 L6818-01 12/29/2003 AcTh-228

-2.25E-03 9.20E-04 4.60E-03 AP 11 L6818-01 12/29/2003 Be-7 8.20E-02 1.10E-02 2.20E-02 AP 11 L6818-01 12/29/2003 Co-58 9.00E-05 4.10E-04 1.70E-03 AP 11 L6818-01 12/29/2003 Co-60 4.00E-04 2.00E-04 2.70E-04 AP 11 L6818-01 12/29/2003 Cs-134

-1.20E-04 1.80E-04 8.80E-04 AP 11 L6818-01 12/29/2003 Cs-137

-5.00E-05 2.20E-04 9.10E-04 AP 12 L5303-02 4/2/2003 AcTh-228 2.10E-03 2.10E-03 7.30E-03 AP 12 L5303-02 4/2/2003 Be-7 1.05E-01 2.10E-02 5.20E-02 AP 12 L5303-02 4/2/2003 Co-58

-1.90E-04 8.40E-04 3.80E-03 AP 12 L5303-02 4/2/2003 Co-60 2.40E-04 2.40E-04 6.40E-04 AP 12 L5303-02 4/2/2003 Cs-134

-7.20E-04 6.10E-04 2.80E-03 AP 12 L5303-02 4/2/2003 Cs-137 4.50E-04 4.90E-04 1.80E-03 AP 12 L5303-02 4/2/2003 K-40 1.19E-02 6.10E-03 1.60E-02 AP 12 L5840-02 6/30/2003 AcTh-228 2.30E-04 8.90E-04 3.60E-03 AP 12 L5840-02 6/30/2003 Be-7 8.70E-02 1.40E-02 3.10E-02 AP 12 L5840-02 6/30/2003 Co-58

-4.60E-04 4.80E-04 2.30E-03 AP 12 L5840-02 6/30/2003 Co-60 5.90E-04 4.10E-04 1.30E-03 AP 12 L5840-02 6/30/2003 Cs-134 7.00E-05 2.30E-04 9.60E-04 AP 12 L5840-02 6/30/2003 Cs-137 6.40E-04 6.20E-04 2.10E-03 AP 12 L5840-02 6/30/2003 K-40 5.60E-03 4.20E-03 1.40E-02 AP 12 L6329-02 9/30/2003 AcTh-228

-1.30E-04 9.80E-04 4.10E-03 AP 12 L6329-02 9/30/2003 Be-7 9.20E-02 1.10E-02 2.20E-02 AP 12 L6329-02 9/30/2003 Co-58

-2.50E-04 5.10E-04 2.20E-03 AP 12 L6329-02 9/30/2003 Co-60 5.00E-05 2.50E-04 1.10E-03 AP 12 L6329-02 9/30/2003 Cs-134

-7.70E-04 3.70E-04 1.80E-03 AP 12 L6329-02 9/30/2003 Cs-137

-4.30E-04 5.40E-04 2.10E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-8 Air Particulates SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 12 L6329-02 9/30/2003 K-40

-3.00E-04 3.70E-03 1.60E-02 AP 12 L6818-02 12/29/2003 AcTh-228

-1.16E-03 5.50E-04 3.20E-03 AP 12 L6818-02 12/29/2003 Be-7 6.42E-02 9.50E-03 1.90E-02 AP 12 L6818-02 12/29/2003 Co-58

-7.90E-04 3.50E-04 1.90E-03 AP 12 L6818-02 12/29/2003 Co-60

-2.50E-04 2.90E-04 1.40E-03 AP 12 L6818-02 12/29/2003 Cs-134 2.60E-04 2.40E-04 8.40E-04 AP 12 L6818-02 12/29/2003 Cs-137 2.00E-05 1.90E-04 7.90E-04 AP 13 L5303-03 4/2/2003 AcTh-228 5.00E-04 2.80E-03 1.20E-02 AP 13 L5303-03 4/2/2003 Be-7 7.10E-02 3.10E-02 9.50E-02 AP 13 L5303-03 4/2/2003 Co-58 1.70E-03 1.20E-03 3.80E-03 AP 13 L5303-03 4/2/2003 Co-60

-1.31E-03 9.20E-04 4.80E-03 AP 13 L5303-03 4/2/2003 Cs-134 1.58E-03 9.40E-04 2.90E-03 AP 13 L5303-03 4/2/2003 Cs-137

-1.10E-04 9.10E-04 3.70E-03 AP 13 L5303-03 4/2/2003 K-40 2.60E-02 1.20E-02 3.20E-02 AP 13 L5840-03 6/30/2003 AcTh-228

-4.00E-04 1.00E-03 4.30E-03 AP 13 L5840-03 6/30/2003 Be-7 8.20E-02 1.20E-02 2.30E-02 AP 13 L5840-03 6/30/2003 Co-58

-1.60E-04 7.30E-04 3.00E-03 AP 13 L5840-03 6/30/2003 Co-60

-4.40E-04 3.30E-04 1.70E-03 AP 13 L5840-03 6/30/2003 Cs-134

-3.80E-04 3.50E-04 1.60E-03 AP 13 L5840-03 6/30/2003 Cs-137 2.10E-04 5.80E-04 2.10E-03 AP 13 L5840-03 6/30/2003 K-40

-4.40E-03 4.20E-03 1.90E-02 AP 13 L6329-03 9/30/2003 AcTh-228 6.00E-04 1.40E-03 5.50E-03 AP 13 L6329-03 9/30/2003 Be-7 9.50E-02 1.40E-02 3.40E-02 AP 13 L6329-03 9/30/2003 Co-58 3.40E-04 3.70E-04 1.40E-03 AP 13 L6329-03 9/30/2003 Co-60 4.40E-04 6.90E-04 2.50E-03 AP 13 L6329-03 9/30/2003 Cs-134 5.60E-04 3.60E-04 1.20E-03 AP 13 L6329-03 9/30/2003 Cs-137 7.00E-05 7.40E-04 2.70E-03 AP 13 L6329-03 9/30/2003 K-40

-4.00E-04 5.50E-03 2.30E-02 AP 13 L6818-03 12/29/2003 AcTh-228 1.10E-03 1.20E-03 4.50E-03 AP 13 L6818-03 12/29/2003 Be-7 1.05E-01 1.50E-02 3.00E-02 AP 13 L6818-03 12/29/2003 Co-58

-5.40E-04 6.50E-04 2.90E-03 AP 13 L6818-03 12/29/2003 Co-60

-1.90E-04 3.30E-04 1.60E-03 AP 13 L6818-03 12/29/2003 Cs-134 1.70E-04 3.40E-04 1.30E-03 AP 13 L6818-03 12/29/2003 Cs-137 2.10E-04 2.70E-04 1.00E-03 AP 14 L5303-04 4/2/2003 AcTh-228 1.10E-03 1.80E-03 6.60E-03 AP 14 L5303-04 4/2/2003 Be-7 1.07E-01 1.70E-02 3.40E-02 AP 14 L5303-04 4/2/2003 Co-58

-1.33E-03 7.50E-04 3.90E-03 AP 14 L5303-04 4/2/2003 Co-60

-7.00E-05 4.70E-04 2.10E-03 AP 14 L5303-04 4/2/2003 Cs-134

-5.00E-05 4.00E-04 1.70E-03 AP 14 L5303-04 4/2/2003 Cs-137

-5.10E-04 3.80E-04 1.80E-03 AP 14 L5303-04 4/2/2003 K-40 1.45E-02 5.60E-03 1.30E-02 AP 14 L5840-04 6/30/2003 AcTh-228 2.00E-04 1.10E-03 4.40E-03 AP 14 L5840-04 6/30/2003 Be-7 6.70E-02 1.20E-02 2.80E-02 AP 14 L5840-04 6/30/2003 Co-58 8.40E-04 7.00E-04 2.40E-03 AP 14 L5840-04 6/30/2003 Co-60 8.00E-05 3.80E-04 1.60E-03 AP 14 L5840-04 6/30/2003 Cs-134

-1.50E-04 2.80E-04 1.30E-03 AP 14 L5840-04 6/30/2003 Cs-137

-3.70E-04 5.50E-04 2.10E-03 AP 14 L5840-04 6/30/2003 K-40 6.00E-04 5.00E-03 2.00E-02

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-9 Air Particulates SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 14 L6329-04 9/30/2003 AcTh-228 1.35E-03 9.90E-04 3.30E-03 AP 14 L6329-04 9/30/2003 Be-7 1.03E-01 1.10E-02 1.90E-02 AP 14 L6329-04 9/30/2003 Co-58

-1.90E-04 3.30E-04 1.60E-03 AP 14 L6329-04 9/30/2003 Co-60

-3.30E-04 2.80E-04 1.40E-03 AP 14 L6329-04 9/30/2003 Cs-134 4.30E-04 2.80E-04 8.90E-04 AP 14 L6329-04 9/30/2003 Cs-137

-3.30E-04 5.20E-04 2.00E-03 AP 14 L6329-04 9/30/2003 K-40 4.40E-03 3.90E-03 1.40E-02 AP 14 L6818-04 12/29/2003 AcTh-228 4.10E-04 9.70E-04 3.80E-03 AP 14 L6818-04 12/29/2003 Be-7 7.20E-02 1.10E-02 2.30E-02 AP 14 L6818-04 12/29/2003 Co-58

-1.00E-04 5.30E-04 2.20E-03 AP 14 L6818-04 12/29/2003 Co-60 1.50E-04 3.60E-04 1.40E-03 AP 14 L6818-04 12/29/2003 Cs-134

-1.60E-04 3.20E-04 1.40E-03 AP 14 L6818-04 12/29/2003 Cs-137 3.40E-04 5.20E-04 1.80E-03 AP 21 L5303-05 4/2/2003 AcTh-228

-2.00E-04 1.40E-03 5.80E-03 AP 21 L5303-05 4/2/2003 Be-7 6.50E-02 1.60E-02 4.10E-02 AP 21 L5303-05 4/2/2003 Co-58

-6.90E-04 8.10E-04 3.60E-03 AP 21 L5303-05 4/2/2003 Co-60

-6.00E-05 4.20E-04 1.90E-03 AP 21 L5303-05 4/2/2003 Cs-134 1.10E-04 4.50E-04 1.80E-03 AP 21 L5303-05 4/2/2003 Cs-137

-1.50E-04 3.80E-04 1.60E-03 AP 21 L5303-05 4/2/2003 K-40 1.46E-02 5.70E-03 1.40E-02 AP 21 L5840-05 6/30/2003 AcTh-228 3.00E-03 1.40E-03 4.00E-03 AP 21 L5840-05 6/30/2003 Be-7 7.70E-02 1.40E-02 3.40E-02 AP 21 L5840-05 6/30/2003 Co-58 5.70E-04 6.80E-04 2.50E-03 AP 21 L5840-05 6/30/2003 Co-60

-5.00E-05 3.60E-04 1.70E-03 AP 21 L5840-05 6/30/2003 Cs-134 3.20E-04 3.80E-04 1.40E-03 AP 21 L5840-05 6/30/2003 Cs-137

-4.50E-04 7.40E-04 2.80E-03 AP 21 L5840-05 6/30/2003 K-40 5.40E-03 4.50E-03 1.50E-02 AP 21 L6329-05 9/30/2003 AcTh-228 1.20E-03 1.30E-03 4.70E-03 AP 21 L6329-05 9/30/2003 Be-7 9.80E-02 1.20E-02 2.10E-02 AP 21 L6329-05 9/30/2003 Co-58 2.30E-04 5.10E-04 2.00E-03 AP 21 L6329-05 9/30/2003 Co-60 2.90E-04 4.20E-04 1.60E-03 AP 21 L6329-05 9/30/2003 Cs-134 3.30E-04 3.90E-04 1.40E-03 AP 21 L6329-05 9/30/2003 Cs-137

-6.20E-04 6.00E-04 2.30E-03 AP 21 L6329-05 9/30/2003 K-40

-5.50E-03 4.70E-03 2.10E-02 AP 21 L6818-05 12/29/2003 AcTh-228

-8.00E-04 1.20E-03 5.10E-03 AP 21 L6818-05 12/29/2003 Be-7 7.50E-02 1.30E-02 3.20E-02 AP 21 L6818-05 12/29/2003 Co-58

-5.30E-04 7.10E-04 3.00E-03 AP 21 L6818-05 12/29/2003 Co-60

-2.40E-04 2.20E-04 1.30E-03 AP 21 L6818-05 12/29/2003 Cs-134 4.00E-05 3.50E-04 1.40E-03 AP 21 L6818-05 12/29/2003 Cs-137

-4.40E-04 5.10E-04 2.00E-03 AP 31 L5303-06 4/2/2003 AcTh-228 3.60E-03 2.30E-03 7.30E-03 AP 31 L5303-06 4/2/2003 Be-7 8.20E-02 2.40E-02 6.70E-02 AP 31 L5303-06 4/2/2003 Co-58

-2.30E-03 1.00E-03 5.50E-03 AP 31 L5303-06 4/2/2003 Co-60

-2.90E-04 2.90E-04 2.00E-03 AP 31 L5303-06 4/2/2003 Cs-134 0.00E+00 7.70E-04 2.90E-03 AP 31 L5303-06 4/2/2003 Cs-137 1.10E-04 6.00E-04 2.40E-03 AP 31 L5303-06 4/2/2003 K-40 7.60E-03 4.40E-03 6.90E-03 AP 31 L5840-06 6/30/2003 AcTh-228 1.90E-03 1.20E-03 3.80E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-10 Air Particulates SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3)

(pCi/m3)

(pCi/m3)

AP 31 L5840-06 6/30/2003 Be-7 9.10E-02 1.30E-02 2.60E-02 AP 31 L5840-06 6/30/2003 Co-58

-5.20E-04 6.40E-04 2.90E-03 AP 31 L5840-06 6/30/2003 Co-60 8.90E-04 4.20E-04 1.10E-03 AP 31 L5840-06 6/30/2003 Cs-134 2.30E-04 4.10E-04 1.50E-03 AP 31 L5840-06 6/30/2003 Cs-137

-8.00E-05 6.10E-04 2.20E-03 AP 31 L5840-06 6/30/2003 K-40 1.90E-03 4.10E-03 1.60E-02 AP 31 L6329-06 9/30/2003 AcTh-228

-1.00E-04 1.10E-03 4.60E-03 AP 31 L6329-06 9/30/2003 Be-7 6.60E-02 1.10E-02 2.50E-02 AP 31 L6329-06 9/30/2003 Co-58 1.00E-04 4.50E-04 1.90E-03 AP 31 L6329-06 9/30/2003 Co-60 7.40E-04 4.70E-04 1.50E-03 AP 31 L6329-06 9/30/2003 Cs-134 3.00E-05 4.00E-04 1.60E-03 AP 31 L6329-06 9/30/2003 Cs-137

-5.30E-04 6.50E-04 2.50E-03 AP 31 L6329-06 9/30/2003 K-40 1.10E-03 4.40E-03 1.80E-02 AP 31 L6818-06 12/29/2003 AcTh-228

-1.60E-03 1.20E-03 5.60E-03 AP 31 L6818-06 12/29/2003 Be-7 1.10E-01 1.40E-02 2.40E-02 AP 31 L6818-06 12/29/2003 Co-58

-1.00E-04 5.90E-04 2.50E-03 AP 31 L6818-06 12/29/2003 Co-60

-3.50E-04 4.80E-04 2.10E-03 AP 31 L6818-06 12/29/2003 Cs-134 1.70E-04 3.70E-04 1.40E-03 AP 31 L6818-06 12/29/2003 Cs-137 4.10E-04 6.30E-04 2.20E-03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-11 Fish SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

FH 11 L5403-01 5/1/2003 Ag-110m

-3.30E+01 1.80E+01 8.50E+01 FH 11 L5403-01 5/1/2003 Ba-140

-3.70E+01 1.80E+01 1.10E+02 FH 11 L5403-01 5/1/2003 Be-7

-1.07E+02 9.80E+01 4.20E+02 FH 11 L5403-01 5/1/2003 Ce-141

-2.40E+01 1.80E+01 7.10E+01 FH 11 L5403-01 5/1/2003 Ce-144 8.80E+01 5.60E+01 1.80E+02 FH 11 L5403-01 5/1/2003 Co-57

-1.70E+00 7.40E+00 2.70E+01 FH 11 L5403-01 5/1/2003 Co-58 1.30E+01 1.30E+01 4.50E+01 FH 11 L5403-01 5/1/2003 Co-60 4.00E+00 1.10E+01 4.70E+01 FH 11 L5403-01 5/1/2003 Cs-134

-1.30E+01 1.40E+01 5.90E+01 FH 11 L5403-01 5/1/2003 Cs-137 2.40E+01 1.40E+01 4.70E+01 FH 11 L5403-01 5/1/2003 Fe-59 4.20E+01 2.80E+01 9.00E+01 FH 11 L5403-01 5/1/2003 I-131

-3.90E+01 3.00E+01 1.20E+02 FH 11 L5403-01 5/1/2003 K-40 2.44E+03 3.90E+02 7.20E+02 FH 11 L5403-01 5/1/2003 La-140

-4.20E+01 2.10E+01 1.30E+02 FH 11 L5403-01 5/1/2003 Mn-54 1.70E+01 1.50E+01 5.20E+01 FH 11 L5403-01 5/1/2003 Nb-95

-5.00E+00 1.10E+01 4.70E+01 FH 11 L5403-01 5/1/2003 Ru-103 1.10E+01 1.30E+01 4.50E+01 FH 11 L5403-01 5/1/2003 Ru-106

-7.00E+01 1.20E+02 4.90E+02 FH 11 L5403-01 5/1/2003 Sb-124 2.70E+01 3.30E+01 1.30E+02 FH 11 L5403-01 5/1/2003 Zn-65 8.00E+00 2.70E+01 1.10E+02 FH 11 L5403-01 5/1/2003 Zr-95

-2.10E+01 2.20E+01 9.80E+01 FH 11 L6363-01 10/14/2003 Ag-110m 1.20E+01 1.90E+01 6.90E+01 FH 11 L6363-01 10/14/2003 Ba-140

-3.20E+02 6.80E+02 3.00E+03 FH 11 L6363-01 10/14/2003 Be-7

-2.60E+02 2.20E+02 9.00E+02 FH 11 L6363-01 10/14/2003 Ce-141

-4.50E+01 7.00E+01 2.60E+02 FH 11 L6363-01 10/14/2003 Ce-144 0.00E+00 7.30E+01 2.60E+02 FH 11 L6363-01 10/14/2003 Co-57

-5.00E-01 9.00E+00 3.30E+01 FH 11 L6363-01 10/14/2003 Co-58

-9.00E+00 1.70E+01 7.40E+01 FH 11 L6363-01 10/14/2003 Co-60 3.00E+00 1.10E+01 4.20E+01 FH 11 L6363-01 10/14/2003 Cs-134 2.20E+01 1.30E+01 4.30E+01 FH 11 L6363-01 10/14/2003 Cs-137 5.70E+01 1.60E+01 4.60E+01 FH 11 L6363-01 10/14/2003 Fe-59

-1.20E+02 1.00E+02 4.40E+02 FH 11 L6363-01 10/14/2003 I-131 8.20E+03 8.10E+03 2.80E+04 FH 11 L6363-01 10/14/2003 K-40 2.33E+03 2.90E+02 4.60E+02 FH 11 L6363-01 10/14/2003 La-140

-3.70E+02 7.80E+02 3.40E+03 FH 11 L6363-01 10/14/2003 Mn-54 5.00E+00 1.30E+01 5.00E+01 FH 11 L6363-01 10/14/2003 Nb-95

-1.07E+02 5.30E+01 2.30E+02 FH 11 L6363-01 10/14/2003 Ru-103

-7.00E+00 3.20E+01 1.30E+02 FH 11 L6363-01 10/14/2003 Ru-106

-1.10E+02 1.20E+02 4.80E+02 FH 11 L6363-01 10/14/2003 Sb-124

-2.20E+01 3.40E+01 1.80E+02 FH 11 L6363-01 10/14/2003 Zn-65

-3.00E+01 3.30E+01 1.40E+02 FH 11 L6363-01 10/14/2003 Zr-95 9.00E+00 3.30E+01 1.30E+02

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-12 Fish SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

FH 21 L5403-02 4/30/2003 Ag-110m 3.70E+01 1.60E+01 4.60E+01 FH 21 L5403-02 4/30/2003 Ba-140

-2.30E+01 1.40E+01 7.70E+01 FH 21 L5403-02 4/30/2003 Be-7

-1.24E+02 8.50E+01 3.60E+02 FH 21 L5403-02 4/30/2003 Ce-141 1.00E+01 1.80E+01 6.30E+01 FH 21 L5403-02 4/30/2003 Ce-144 0.00E+00 5.50E+01 2.00E+02 FH 21 L5403-02 4/30/2003 Co-57 1.00E+01 8.00E+00 2.70E+01 FH 21 L5403-02 4/30/2003 Co-58 1.40E+01 1.30E+01 4.50E+01 FH 21 L5403-02 4/30/2003 Co-60 1.50E+01 1.40E+01 4.70E+01 FH 21 L5403-02 4/30/2003 Cs-134

-5.00E+00 1.10E+01 4.30E+01 FH 21 L5403-02 4/30/2003 Cs-137 1.70E+01 1.20E+01 4.00E+01 FH 21 L5403-02 4/30/2003 Fe-59

-1.40E+01 2.90E+01 1.10E+02 FH 21 L5403-02 4/30/2003 I-131

-4.00E+00 3.00E+01 1.10E+02 FH 21 L5403-02 4/30/2003 K-40 1.99E+03 3.00E+02 6.70E+02 FH 21 L5403-02 4/30/2003 La-140

-2.70E+01 1.60E+01 8.80E+01 FH 21 L5403-02 4/30/2003 Mn-54 0.00E+00 1.10E+01 4.30E+01 FH 21 L5403-02 4/30/2003 Nb-95 0.00E+00 1.30E+01 4.80E+01 FH 21 L5403-02 4/30/2003 Ru-103

-1.60E+01 1.20E+01 4.90E+01 FH 21 L5403-02 4/30/2003 Ru-106 1.60E+02 1.10E+02 3.50E+02 FH 21 L5403-02 4/30/2003 Sb-124 4.10E+01 2.50E+01 7.60E+01 FH 21 L5403-02 4/30/2003 Zn-65 3.00E+00 2.70E+01 1.00E+02 FH 21 L5403-02 4/30/2003 Zr-95 1.60E+01 2.30E+01 8.30E+01 FH 21 L6363-02 10/14/2003 Ag-110m 1.10E+01 2.10E+01 7.90E+01 FH 21 L6363-02 10/14/2003 Ba-140 0.00E+00 8.70E+02 3.80E+03 FH 21 L6363-02 10/14/2003 Be-7

-1.60E+02 1.90E+02 8.40E+02 FH 21 L6363-02 10/14/2003 Ce-141 1.10E+01 6.70E+01 2.40E+02 FH 21 L6363-02 10/14/2003 Ce-144

-4.10E+01 4.30E+01 1.80E+02 FH 21 L6363-02 10/14/2003 Co-57

-2.20E+00 6.20E+00 2.40E+01 FH 21 L6363-02 10/14/2003 Co-58

-5.00E+00 2.20E+01 9.20E+01 FH 21 L6363-02 10/14/2003 Co-60 1.90E+01 1.70E+01 6.10E+01 FH 21 L6363-02 10/14/2003 Cs-134

-3.00E+00 1.40E+01 5.80E+01 FH 21 L6363-02 10/14/2003 Cs-137 1.30E+01 1.20E+01 4.20E+01 FH 21 L6363-02 10/14/2003 Fe-59 2.10E+02 1.40E+02 4.40E+02 FH 21 L6363-02 10/14/2003 I-131 8.20E+03 6.60E+03 2.20E+04 FH 21 L6363-02 10/14/2003 K-40 1.97E+03 3.80E+02 8.20E+02 FH 21 L6363-02 10/14/2003 La-140 0.00E+00 1.00E+03 4.40E+03 FH 21 L6363-02 10/14/2003 Mn-54 1.70E+01 1.50E+01 5.30E+01 FH 21 L6363-02 10/14/2003 Nb-95

-4.50E+01 5.40E+01 2.40E+02 FH 21 L6363-02 10/14/2003 Ru-103 3.70E+01 3.20E+01 1.10E+02 FH 21 L6363-02 10/14/2003 Ru-106 6.00E+01 1.10E+02 4.00E+02 FH 21 L6363-02 10/14/2003 Sb-124

-6.30E+01 4.50E+01 2.90E+02 FH 21 L6363-02 10/14/2003 Zn-65

-2.10E+01 2.60E+01 1.30E+02 FH 21 L6363-02 10/14/2003 Zr-95 4.70E+01 3.80E+01 1.30E+02

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-13 Maple Syrup SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

MS 33 L5196-01 4/3/2003 AcTh-228 1.57E+01 7.60E+00 2.30E+01 MS 33 L5196-01 4/3/2003 Ag-110m 0.00E+00 3.20E+00 1.20E+01 MS 33 L5196-01 4/3/2003 Ba-140 9.00E-01 3.00E+00 1.20E+01 MS 33 L5196-01 4/3/2003 Be-7 2.80E+01 1.80E+01 5.90E+01 MS 33 L5196-01 4/3/2003 Ce-141 5.00E-01 3.40E+00 1.20E+01 MS 33 L5196-01 4/3/2003 Ce-144 1.80E+01 1.30E+01 4.40E+01 MS 33 L5196-01 4/3/2003 Co-57

-2.40E+00 1.80E+00 6.70E+00 MS 33 L5196-01 4/3/2003 Co-58 1.10E+00 2.00E+00 7.10E+00 MS 33 L5196-01 4/3/2003 Co-60 5.00E-01 2.40E+00 9.10E+00 MS 33 L5196-01 4/3/2003 Cs-134

-1.20E+00 2.70E+00 1.00E+01 MS 33 L5196-01 4/3/2003 Cs-137 1.24E+01 3.60E+00 1.10E+01 MS 33 L5196-01 4/3/2003 Fe-59

-1.70E+00 5.00E+00 1.90E+01 MS 33 L5196-01 4/3/2003 I-131 5.00E-01 3.30E+00 1.20E+01 MS 33 L5196-01 4/3/2003 K-40 2.20E+03 1.10E+02 1.10E+02 MS 33 L5196-01 4/3/2003 La-140 1.10E+00 3.50E+00 1.30E+01 MS 33 L5196-01 4/3/2003 Mn-54 4.00E-01 2.10E+00 7.70E+00 MS 33 L5196-01 4/3/2003 Nb-95

-1.00E+00 2.40E+00 9.10E+00 MS 33 L5196-01 4/3/2003 Ru-103 0.00E+00 2.10E+00 7.80E+00 MS 33 L5196-01 4/3/2003 Ru-106 0.00E+00 1.90E+01 7.10E+01 MS 33 L5196-01 4/3/2003 Sb-124 7.70E+00 3.80E+00 1.00E+01 MS 33 L5196-01 4/3/2003 Zn-65

-6.60E+00 6.70E+00 2.60E+01 MS 33 L5196-01 4/3/2003 Zr-95 1.30E+00 3.60E+00 1.30E+01 MS 45 L5196-02 4/2/2003 AcTh-228 1.25E+01 8.00E+00 2.60E+01 MS 45 L5196-02 4/2/2003 Ag-110m 2.00E+00 3.50E+00 1.20E+01 MS 45 L5196-02 4/2/2003 Ba-140

-8.00E-01 1.70E+00 8.10E+00 MS 45 L5196-02 4/2/2003 Be-7 1.80E+01 1.50E+01 5.00E+01 MS 45 L5196-02 4/2/2003 Ce-141

-2.60E+00 3.30E+00 1.20E+01 MS 45 L5196-02 4/2/2003 Ce-144 3.00E+00 1.30E+01 4.40E+01 MS 45 L5196-02 4/2/2003 Co-57 2.40E+00 1.50E+00 5.10E+00 MS 45 L5196-02 4/2/2003 Co-58

-1.50E+00 2.00E+00 7.90E+00 MS 45 L5196-02 4/2/2003 Co-60

-4.30E+00 2.40E+00 1.10E+01 MS 45 L5196-02 4/2/2003 Cs-134 3.30E+00 2.10E+00 7.00E+00 MS 45 L5196-02 4/2/2003 Cs-137 1.84E+01 3.80E+00 1.10E+01 MS 45 L5196-02 4/2/2003 Fe-59

-1.15E+01 5.30E+00 2.20E+01 MS 45 L5196-02 4/2/2003 I-131

-3.50E+00 3.30E+00 1.20E+01 MS 45 L5196-02 4/2/2003 K-40 2.27E+03 1.10E+02 9.40E+01 MS 45 L5196-02 4/2/2003 La-140

-9.00E-01 1.90E+00 9.30E+00 MS 45 L5196-02 4/2/2003 Mn-54

-9.00E-01 1.70E+00 7.00E+00 MS 45 L5196-02 4/2/2003 Nb-95

-4.20E+00 2.30E+00 9.60E+00 MS 45 L5196-02 4/2/2003 Ru-103 1.10E+00 2.00E+00 7.10E+00 MS 45 L5196-02 4/2/2003 Ru-106

-1.00E+01 1.90E+01 7.40E+01 MS 45 L5196-02 4/2/2003 Sb-124 1.30E+00 2.90E+00 1.20E+01 MS 45 L5196-02 4/2/2003 Zn-65

-1.27E+01 5.90E+00 2.50E+01 MS 45 L5196-02 4/2/2003 Zr-95

-1.90E+00 3.30E+00 1.30E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-15 Sediment SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

SE1 11 L5359-01 4/19/2003 AcTh-228 8.28E+02 7.00E+01 2.60E+02 SE1 11 L5359-01 4/19/2003 Be-7 1.50E+02 1.90E+02 6.70E+02 SE1 11 L5359-01 4/19/2003 Co-58 1.30E+01 2.00E+01 6.80E+01 SE1 11 L5359-01 4/19/2003 Co-60 7.00E+00 1.80E+01 6.30E+01 SE1 11 L5359-01 4/19/2003 Cs-134 1.30E+01 2.10E+01 7.30E+01 SE1 11 L5359-01 4/19/2003 Cs-137 1.30E+02 2.70E+01 7.70E+01 SE1 11 L5359-01 4/19/2003 K-40 1.36E+04 6.00E+02 5.80E+02 SE2 11 L5359-02 4/19/2003 AcTh-228 1.01E+03 7.60E+01 2.20E+02 SE2 11 L5359-02 4/19/2003 Be-7 1.80E+02 2.10E+02 7.20E+02 SE2 11 L5359-02 4/19/2003 Co-58

-1.10E+01 2.30E+01 8.60E+01 SE2 11 L5359-02 4/19/2003 Co-60

-5.00E+00 1.60E+01 6.10E+01 SE2 11 L5359-02 4/19/2003 Cs-134 2.60E+01 2.00E+01 6.80E+01 SE2 11 L5359-02 4/19/2003 Cs-137 2.42E+02 3.00E+01 7.60E+01 SE2 11 L5359-02 4/19/2003 K-40 1.58E+04 6.70E+02 5.80E+02 SE3 11 L5359-03 4/19/2003 AcTh-228 8.66E+02 6.80E+01 2.10E+02 SE3 11 L5359-03 4/19/2003 Be-7

-3.40E+02 1.90E+02 7.40E+02 SE3 11 L5359-03 4/19/2003 Co-58

-1.50E+01 2.20E+01 8.30E+01 SE3 11 L5359-03 4/19/2003 Co-60

-2.40E+01 1.60E+01 6.70E+01 SE3 11 L5359-03 4/19/2003 Cs-134 2.10E+01 2.00E+01 6.80E+01 SE3 11 L5359-03 4/19/2003 Cs-137 1.50E+02 2.50E+01 6.50E+01 SE3 11 L5359-03 4/19/2003 K-40 1.62E+04 7.10E+02 5.50E+02 SE1 11 L6443-01 10/30/2003 AcTh-228 9.42E+02 6.20E+01 2.30E+02 SE1 11 L6443-01 10/30/2003 Be-7 0.00E+00 1.70E+02 5.90E+02 SE1 11 L6443-01 10/30/2003 Co-58 6.00E+00 1.80E+01 6.50E+01 SE1 11 L6443-01 10/30/2003 Co-60

-1.60E+01 1.70E+01 6.50E+01 SE1 11 L6443-01 10/30/2003 Cs-134 4.00E+00 1.40E+01 5.00E+01 SE1 11 L6443-01 10/30/2003 Cs-137 2.13E+02 2.60E+01 6.70E+01 SE1 11 L6443-01 10/30/2003 K-40 1.56E+04 5.90E+02 5.00E+02 SE2 11 L6443-02 10/30/2003 AcTh-228 8.88E+02 5.70E+01 2.20E+02 SE2 11 L6443-02 10/30/2003 Be-7

-7.00E+01 1.50E+02 5.50E+02 SE2 11 L6443-02 10/30/2003 Co-58

-2.20E+01 1.70E+01 6.40E+01 SE2 11 L6443-02 10/30/2003 Co-60

-1.00E+01 1.40E+01 5.50E+01 SE2 11 L6443-02 10/30/2003 Cs-134 1.00E+00 1.20E+01 4.10E+01 SE2 11 L6443-02 10/30/2003 Cs-137 2.26E+02 2.40E+01 5.90E+01 SE2 11 L6443-02 10/30/2003 K-40 1.64E+04 6.00E+02 5.10E+02 SE3 11 L6443-03 10/30/2003 AcTh-228 9.98E+02 6.50E+01 1.90E+02 SE3 11 L6443-03 10/30/2003 Be-7 1.60E+02 1.60E+02 5.30E+02 SE3 11 L6443-03 10/30/2003 Co-58 4.00E+00 1.70E+01 6.20E+01 SE3 11 L6443-03 10/30/2003 Co-60

-9.00E+00 1.60E+01 5.90E+01 SE3 11 L6443-03 10/30/2003 Cs-134 4.00E+00 1.40E+01 4.80E+01 SE3 11 L6443-03 10/30/2003 Cs-137 3.39E+02 2.90E+01 6.50E+01 SE3 11 L6443-03 10/30/2003 K-40 1.75E+04 6.20E+02 5.60E+02

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-16 Sediment SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

SE1 21 L5359-04 4/23/2003 AcTh-228 5.98E+02 5.70E+01 2.00E+02 SE1 21 L5359-04 4/23/2003 Be-7

-6.00E+01 1.60E+02 5.80E+02 SE1 21 L5359-04 4/23/2003 Co-58 9.00E+00 1.80E+01 6.40E+01 SE1 21 L5359-04 4/23/2003 Co-60 9.00E+00 1.70E+01 6.00E+01 SE1 21 L5359-04 4/23/2003 Cs-134 1.20E+01 1.20E+01 4.10E+01 SE1 21 L5359-04 4/23/2003 Cs-137 1.26E+02 2.20E+01 6.20E+01 SE1 21 L5359-04 4/23/2003 K-40 1.51E+04 6.20E+02 5.20E+02 SE2 21 L5359-05 4/23/2003 AcTh-228 5.29E+02 4.40E+01 1.50E+02 SE2 21 L5359-05 4/23/2003 Be-7 1.00E+02 1.30E+02 4.50E+02 SE2 21 L5359-05 4/23/2003 Co-58

-2.00E+01 1.50E+01 5.70E+01 SE2 21 L5359-05 4/23/2003 Co-60

-1.00E+01 1.00E+01 3.90E+01 SE2 21 L5359-05 4/23/2003 Cs-134 1.50E+01 1.40E+01 4.60E+01 SE2 21 L5359-05 4/23/2003 Cs-137 1.18E+02 1.70E+01 4.60E+01 SE2 21 L5359-05 4/23/2003 K-40 1.57E+04 4.80E+02 3.60E+02 SE3 21 L5359-06 4/23/2003 AcTh-228 4.97E+02 4.60E+01 1.50E+02 SE3 21 L5359-06 4/23/2003 Be-7

-2.00E+01 1.30E+02 4.50E+02 SE3 21 L5359-06 4/23/2003 Co-58

-2.00E+01 1.20E+01 4.80E+01 SE3 21 L5359-06 4/23/2003 Co-60

-1.90E+01 1.20E+01 4.70E+01 SE3 21 L5359-06 4/23/2003 Cs-134

-1.60E+01 4.30E+01 1.40E+02 SE3 21 L5359-06 4/23/2003 Cs-137 1.23E+02 1.70E+01 4.60E+01 SE3 21 L5359-06 4/23/2003 K-40 1.45E+04 4.70E+02 3.90E+02 SE1 21 L6443-04 10/30/2003 AcTh-228 4.91E+02 4.40E+01 1.50E+02 SE1 21 L6443-04 10/30/2003 Be-7 2.00E+01 1.40E+02 5.00E+02 SE1 21 L6443-04 10/30/2003 Co-58 4.00E+00 1.30E+01 4.50E+01 SE1 21 L6443-04 10/30/2003 Co-60 5.00E-01 9.40E+00 3.40E+01 SE1 21 L6443-04 10/30/2003 Cs-134

-5.80E+01 4.00E+01 1.30E+02 SE1 21 L6443-04 10/30/2003 Cs-137 8.53E+02 3.00E+01 4.20E+01 SE1 21 L6443-04 10/30/2003 K-40 1.70E+04 4.60E+02 3.40E+02 SE2 21 L6443-05 10/30/2003 AcTh-228 5.70E+02 4.10E+01 1.50E+02 SE2 21 L6443-05 10/30/2003 Be-7

-4.00E+01 1.20E+02 4.30E+02 SE2 21 L6443-05 10/30/2003 Co-58 6.00E+00 1.30E+01 4.60E+01 SE2 21 L6443-05 10/30/2003 Co-60 1.10E+01 1.00E+01 3.50E+01 SE2 21 L6443-05 10/30/2003 Cs-134 8.00E+00 1.00E+01 3.50E+01 SE2 21 L6443-05 10/30/2003 Cs-137 7.40E+01 1.40E+01 4.00E+01 SE2 21 L6443-05 10/30/2003 K-40 1.68E+04 4.60E+02 4.00E+02 SE3 21 L6443-06 10/30/2003 AcTh-228 6.42E+02 4.70E+01 1.60E+02 SE3 21 L6443-06 10/30/2003 Be-7

-1.90E+02 1.30E+02 4.60E+02 SE3 21 L6443-06 10/30/2003 Co-58 0.00E+00 1.30E+01 4.60E+01 SE3 21 L6443-06 10/30/2003 Co-60

-3.10E+01 1.10E+01 4.50E+01 SE3 21 L6443-06 10/30/2003 Cs-134 4.00E+00 4.00E+01 1.30E+02 SE3 21 L6443-06 10/30/2003 Cs-137 3.20E+01 1.50E+01 5.00E+01 SE3 21 L6443-06 10/30/2003 K-40 2.04E+04 5.10E+02 4.10E+02 SE1 91 L5359-07 4/23/2003 AcTh-228 1.66E+03 1.50E+02 6.50E+02 SE1 91 L5359-07 4/23/2003 Be-7

-2.60E+02 4.00E+02 1.40E+03 SE1 91 L5359-07 4/23/2003 Co-58 2.60E+01 3.80E+01 1.30E+02 SE1 91 L5359-07 4/23/2003 Co-60

-6.30E+01 4.10E+01 1.60E+02 SE1 91 L5359-07 4/23/2003 Cs-134 7.50E+01 3.80E+01 1.20E+02

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-17 Sediment SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

SE1 91 L5359-07 4/23/2003 Cs-137 1.65E+03 8.80E+01 1.60E+02 SE1 91 L5359-07 4/23/2003 K-40 2.75E+04 1.30E+03 1.70E+03 SE2 91 L5359-08 4/23/2003 AcTh-228 1.49E+03 5.90E+01 2.20E+02 SE2 91 L5359-08 4/23/2003 Be-7

-1.90E+02 2.00E+02 6.90E+02 SE2 91 L5359-08 4/23/2003 Co-58

-8.00E+00 1.80E+01 6.30E+01 SE2 91 L5359-08 4/23/2003 Co-60 1.90E+01 1.50E+01 4.80E+01 SE2 91 L5359-08 4/23/2003 Cs-134

-1.10E+01 2.10E+01 7.10E+01 SE2 91 L5359-08 4/23/2003 Cs-137 1.70E+03 4.00E+01 6.70E+01 SE2 91 L5359-08 4/23/2003 K-40 2.48E+04 5.30E+02 6.50E+02 SE3 91 L5359-09 4/23/2003 AcTh-228 1.61E+03 4.80E+01 1.90E+02 SE3 91 L5359-09 4/23/2003 Be-7 9.00E+01 1.50E+02 5.10E+02 SE3 91 L5359-09 4/23/2003 Co-58

-3.60E+01 1.60E+01 5.50E+01 SE3 91 L5359-09 4/23/2003 Co-60 2.40E+01 1.20E+01 4.00E+01 SE3 91 L5359-09 4/23/2003 Cs-134

-3.10E+01 1.50E+01 5.20E+01 SE3 91 L5359-09 4/23/2003 Cs-137 1.10E+03 2.80E+01 5.40E+01 SE3 91 L5359-09 4/23/2003 K-40 2.55E+04 4.50E+02 5.20E+02 SE1 91 L6443-07 10/30/2003 AcTh-228 1.70E+03 1.50E+02 5.90E+02 SE1 91 L6443-07 10/30/2003 Be-7 2.00E+01 4.80E+02 1.70E+03 SE1 91 L6443-07 10/30/2003 Co-58 1.10E+01 4.50E+01 1.60E+02 SE1 91 L6443-07 10/30/2003 Co-60 5.70E+01 3.90E+01 1.30E+02 SE1 91 L6443-07 10/30/2003 Cs-134

-3.20E+01 4.00E+01 1.50E+02 SE1 91 L6443-07 10/30/2003 Cs-137 1.76E+03 9.30E+01 1.50E+02 SE1 91 L6443-07 10/30/2003 K-40 2.48E+04 1.20E+03 1.50E+03 SE2 91 L6443-08 10/30/2003 AcTh-228 1.14E+03 1.50E+02 5.80E+02 SE2 91 L6443-08 10/30/2003 Be-7

-5.10E+02 4.30E+02 1.60E+03 SE2 91 L6443-08 10/30/2003 Co-58 2.50E+01 4.60E+01 1.60E+02 SE2 91 L6443-08 10/30/2003 Co-60 2.70E+01 3.70E+01 1.30E+02 SE2 91 L6443-08 10/30/2003 Cs-134 1.13E+02 4.40E+01 1.40E+02 SE2 91 L6443-08 10/30/2003 Cs-137 1.94E+03 9.60E+01 1.60E+02 SE2 91 L6443-08 10/30/2003 K-40 2.57E+04 1.30E+03 1.70E+03 SE3 91 L6443-09 10/30/2003 AcTh-228 1.46E+03 9.00E+01 3.70E+02 SE3 91 L6443-09 10/30/2003 Be-7 9.00E+01 3.00E+02 1.00E+03 SE3 91 L6443-09 10/30/2003 Co-58

-1.20E+01 2.80E+01 1.00E+02 SE3 91 L6443-09 10/30/2003 Co-60 1.00E+01 2.50E+01 8.60E+01 SE3 91 L6443-09 10/30/2003 Cs-134 7.90E+01 2.80E+01 8.70E+01 SE3 91 L6443-09 10/30/2003 Cs-137 1.21E+03 5.40E+01 9.70E+01 SE3 91 L6443-09 10/30/2003 K-40 2.55E+04 8.40E+02 9.40E+02

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-18 Food SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

TF 11 L6061-01 8/28/2003 Co-58 1.70E+01 1.10E+01 3.60E+01 TF 11 L6061-01 8/28/2003 Co-60 2.00E+00 1.30E+01 5.40E+01 TF 11 L6061-01 8/28/2003 Cs-134

-6.00E+00 1.00E+01 4.50E+01 TF 11 L6061-01 8/28/2003 Cs-137 3.00E+00 1.10E+01 4.10E+01 TF 11 L6061-01 8/28/2003 I-131

-4.00E+00 2.30E+01 9.40E+01 TF 11 L6061-01 8/28/2003 K-40 9.70E+02 2.70E+02 7.00E+02 TF 13 L6061-02 8/28/2003 Co-58

-2.00E+00 1.30E+01 4.70E+01 TF 13 L6061-02 8/28/2003 Co-60 1.10E+01 1.20E+01 4.20E+01 TF 13 L6061-02 8/28/2003 Cs-134

-7.00E+00 1.30E+01 4.80E+01 TF 13 L6061-02 8/28/2003 Cs-137 3.00E+00 1.10E+01 4.00E+01 TF 13 L6061-02 8/28/2003 I-131

-3.80E+01 3.40E+01 1.30E+02 TF 13 L6061-02 8/28/2003 K-40 6.36E+03 4.00E+02 5.90E+02 TF 21 L6061-03 8/28/2003 Co-58

-2.00E+00 1.00E+01 3.90E+01 TF 21 L6061-03 8/28/2003 Co-60

-1.50E+01 1.10E+01 4.90E+01 TF 21 L6061-03 8/28/2003 Cs-134

-1.62E+01 7.70E+00 3.70E+01 TF 21 L6061-03 8/28/2003 Cs-137

-3.40E+00 7.90E+00 3.20E+01 TF 21 L6061-03 8/28/2003 I-131 1.20E+01 2.70E+01 9.60E+01 TF 21 L6061-03 8/28/2003 K-40 1.77E+03 2.30E+02 4.20E+02

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-19 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 11 L4583-04 1/1/2003 Ba-140

-4.00E-01 2.00E+00 8.00E+00 WG 11 L4583-04 1/1/2003 Co-58

-1.80E+00 1.40E+00 5.50E+00 WG 11 L4583-04 1/1/2003 Co-60 1.00E+00 1.20E+00 4.10E+00 WG 11 L4583-04 1/1/2003 Cs-134

-8.00E-01 1.50E+00 5.50E+00 WG 11 L4583-04 1/1/2003 Cs-137 9.00E-01 1.30E+00 4.50E+00 WG 11 L4583-04 1/1/2003 Fe-59 4.70E+00 2.50E+00 7.90E+00 WG 11 L4583-04 1/1/2003 GR-B 4.60E+00 1.10E+00 2.90E+00 WG 11 L4583-04 1/1/2003 H-3

-3.00E+01 1.20E+02 3.70E+02 WG 11 L4583-04 1/1/2003 I-131

-2.10E+00 2.40E+00 8.90E+00 WG 11 L4583-04 1/1/2003 Mn-54

-5.00E-01 1.60E+00 5.80E+00 WG 11 L4583-04 1/1/2003 Zn-65

-5.90E+00 3.20E+00 1.30E+01 WG 11 L4583-04 1/1/2003 Zr-95 1.70E+00 2.10E+00 7.30E+00 WG 11 L4795-04 1/29/2003 Ba-140 5.70E+00 2.40E+00 6.90E+00 WG 11 L4795-04 1/29/2003 Co-58

-4.00E-01 1.50E+00 5.40E+00 WG 11 L4795-04 1/29/2003 Co-60 1.00E-01 1.70E+00 6.10E+00 WG 11 L4795-04 1/29/2003 Cs-134 1.00E-01 1.40E+00 5.30E+00 WG 11 L4795-04 1/29/2003 Cs-137

-3.70E+00 1.60E+00 6.40E+00 WG 11 L4795-04 1/29/2003 Fe-59 0.00E+00 2.80E+00 1.10E+01 WG 11 L4795-04 1/29/2003 GR-B 2.43E+00 9.20E-01 2.80E+00 WG 11 L4795-04 1/29/2003 H-3 1.50E+02 1.20E+02 3.50E+02 WG 11 L4795-04 1/29/2003 I-131

-8.20E+00 2.90E+00 1.10E+01 WG 11 L4795-04 1/29/2003 Mn-54

-3.00E-01 1.60E+00 5.80E+00 WG 11 L4795-04 1/29/2003 Zn-65 4.00E+00 6.70E+00 2.30E+01 WG 11 L4795-04 1/29/2003 Zr-95

-7.00E-01 2.20E+00 8.50E+00 WG 11 L4971-04 2/25/2003 Ba-140 0.00E+00 1.50E+00 5.60E+00 WG 11 L4971-04 2/25/2003 Co-58

-1.48E+00 9.20E-01 3.60E+00 WG 11 L4971-04 2/25/2003 Co-60 3.00E-01 8.70E-01 3.10E+00 WG 11 L4971-04 2/25/2003 Cs-134

-7.90E-01 9.60E-01 3.60E+00 WG 11 L4971-04 2/25/2003 Cs-137

-7.00E-02 8.20E-01 3.00E+00 WG 11 L4971-04 2/25/2003 Fe-59 1.00E+00 1.80E+00 6.40E+00 WG 11 L4971-04 2/25/2003 GR-B 2.80E+00 9.60E-01 2.80E+00 WG 11 L4971-04 2/25/2003 H-3

-8.30E+01 8.80E+01 2.80E+02 WG 11 L4971-04 2/25/2003 I-131 4.00E-01 1.70E+00 6.00E+00 WG 11 L4971-04 2/25/2003 Mn-54

-2.00E-01 8.80E-01 3.20E+00 WG 11 L4971-04 2/25/2003 Zn-65 5.00E-01 3.70E+00 1.30E+01 WG 11 L4971-04 2/25/2003 Zr-95

-5.00E-01 1.30E+00 5.00E+00 WG 11 L5212-04 4/2/2003 Ba-140 3.50E+00 2.20E+00 7.20E+00 WG 11 L5212-04 4/2/2003 Co-58

-8.00E-01 1.50E+00 5.80E+00 WG 11 L5212-04 4/2/2003 Co-60 1.60E+00 1.20E+00 4.10E+00 WG 11 L5212-04 4/2/2003 Cs-134 2.00E-01 1.50E+00 5.60E+00 WG 11 L5212-04 4/2/2003 Cs-137

-2.40E+00 1.40E+00 5.80E+00 WG 11 L5212-04 4/2/2003 Fe-59 1.60E+00 2.90E+00 1.00E+01 WG 11 L5212-04 4/2/2003 GR-B 3.73E+00 9.70E-01 2.70E+00 WG 11 L5212-04 4/2/2003 H-3

-7.50E+01 8.90E+01 2.80E+02 WG 11 L5212-04 4/2/2003 I-131 4.40E+00 2.40E+00 7.90E+00 WG 11 L5212-04 4/2/2003 Mn-54

-1.40E+00 1.40E+00 5.60E+00 WG 11 L5212-04 4/2/2003 Zn-65

-7.70E+00 5.90E+00 2.20E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-20 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 11 L5212-04 4/2/2003 Zr-95

-1.50E+00 2.60E+00 1.00E+01 WG 11 L5373-05 4/29/2003 Ba-140

-1.30E+00 1.90E+00 8.00E+00 WG 11 L5373-05 4/29/2003 Co-58

-3.00E-01 1.90E+00 7.00E+00 WG 11 L5373-05 4/29/2003 Co-60 2.20E+00 1.60E+00 5.50E+00 WG 11 L5373-05 4/29/2003 Cs-134

-9.00E-01 2.20E+00 8.30E+00 WG 11 L5373-05 4/29/2003 Cs-137

-2.40E+00 1.80E+00 7.10E+00 WG 11 L5373-05 4/29/2003 Fe-59

-1.10E+00 3.50E+00 1.30E+01 WG 11 L5373-05 4/29/2003 GR-B 2.77E+00 9.20E-01 2.70E+00 WG 11 L5373-05 4/29/2003 H-3

-2.10E+01 9.70E+01 3.00E+02 WG 11 L5373-05 4/29/2003 I-131 0.00E+00 2.50E+00 8.80E+00 WG 11 L5373-05 4/29/2003 Mn-54

-1.30E+00 2.10E+00 7.90E+00 WG 11 L5373-05 4/29/2003 Zn-65

-6.90E+00 4.10E+00 1.70E+01 WG 11 L5373-05 4/29/2003 Zr-95

-1.90E+00 3.00E+00 1.20E+01 WG 11 L5530-04 5/27/2003 Ba-140 6.00E-01 3.00E+00 1.10E+01 WG 11 L5530-04 5/27/2003 Co-58

-4.00E-01 1.90E+00 7.10E+00 WG 11 L5530-04 5/27/2003 Co-60 2.00E+00 1.50E+00 5.10E+00 WG 11 L5530-04 5/27/2003 Cs-134

-2.60E+00 1.80E+00 7.20E+00 WG 11 L5530-04 5/27/2003 Cs-137

-3.10E+00 1.70E+00 6.80E+00 WG 11 L5530-04 5/27/2003 Fe-59 1.80E+00 3.40E+00 1.20E+01 WG 11 L5530-04 5/27/2003 GR-B 2.85E+00 9.10E-01 2.70E+00 WG 11 L5530-04 5/27/2003 H-3

-2.12E+02 8.00E+01 2.60E+02 WG 11 L5530-04 5/27/2003 I-131

-5.00E-01 2.90E+00 1.00E+01 WG 11 L5530-04 5/27/2003 Mn-54

-2.70E+00 2.00E+00 7.80E+00 WG 11 L5530-04 5/27/2003 Zn-65 3.80E+00 5.50E+00 1.80E+01 WG 11 L5530-04 5/27/2003 Zr-95 1.60E+00 2.80E+00 1.00E+01 WG 11 L5724-04 6/30/2003 Ba-140 3.00E-01 1.70E+00 6.40E+00 WG 11 L5724-04 6/30/2003 Co-58 2.70E+00 2.40E+00 8.00E+00 WG 11 L5724-04 6/30/2003 Co-60

-4.00E-01 1.10E+00 4.20E+00 WG 11 L5724-04 6/30/2003 Cs-134 1.10E+00 1.40E+00 4.70E+00 WG 11 L5724-04 6/30/2003 Cs-137

-1.00E-01 2.10E+00 7.20E+00 WG 11 L5724-04 6/30/2003 Fe-59 1.60E+00 2.70E+00 9.40E+00 WG 11 L5724-04 6/30/2003 GR-B 2.29E+00 9.50E-01 2.90E+00 WG 11 L5724-04 6/30/2003 H-3 0.00E+00 8.10E+01 2.50E+02 WG 11 L5724-04 6/30/2003 I-131

-1.10E+00 2.40E+00 8.30E+00 WG 11 L5724-04 6/30/2003 Mn-54

-7.00E-01 1.30E+00 4.80E+00 WG 11 L5724-04 6/30/2003 Zn-65

-5.90E+00 6.90E+00 2.40E+01 WG 11 L5724-04 6/30/2003 Zr-95 3.00E-01 2.50E+00 8.80E+00 WG 11 L5906-05 7/29/2003 Ba-140 5.00E-01 2.70E+00 1.00E+01 WG 11 L5906-05 7/29/2003 Co-58

-1.80E+00 1.30E+00 5.20E+00 WG 11 L5906-05 7/29/2003 Co-60 6.00E-01 1.20E+00 4.40E+00 WG 11 L5906-05 7/29/2003 Cs-134

-7.00E-01 1.10E+00 4.20E+00 WG 11 L5906-05 7/29/2003 Cs-137

-8.00E-01 1.20E+00 4.50E+00 WG 11 L5906-05 7/29/2003 Fe-59 3.00E-01 2.70E+00 1.00E+01 WG 11 L5906-05 7/29/2003 GR-B 4.20E+00 1.00E+00 2.80E+00 WG 11 L5906-05 7/29/2003 H-3 1.80E+02 1.30E+02 3.70E+02 WG 11 L5906-05 7/29/2003 I-131 1.50E+00 3.50E+00 1.20E+01 WG 11 L5906-05 7/29/2003 Mn-54 0.00E+00 1.00E+00 3.80E+00 WG 11 L5906-05 7/29/2003 Zn-65 4.90E+00 5.40E+00 1.80E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-21 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 11 L5906-05 7/29/2003 Zr-95

-6.00E-01 2.10E+00 7.80E+00 WG 11 L6026-04 8/25/2003 Ba-140 3.10E+00 2.40E+00 8.10E+00 WG 11 L6026-04 8/25/2003 Co-58

-1.00E+00 1.60E+00 6.30E+00 WG 11 L6026-04 8/25/2003 Co-60 1.20E+00 1.40E+00 5.10E+00 WG 11 L6026-04 8/25/2003 Cs-134 1.40E+00 1.60E+00 5.60E+00 WG 11 L6026-04 8/25/2003 Cs-137

-2.90E+00 1.70E+00 6.80E+00 WG 11 L6026-04 8/25/2003 Fe-59

-8.50E+00 5.20E+00 2.20E+01 WG 11 L6026-04 8/25/2003 GR-B 4.60E+00 1.10E+00 2.80E+00 WG 11 L6026-04 8/25/2003 H-3 1.80E+02 1.30E+02 3.70E+02 WG 11 L6026-04 8/25/2003 I-131 3.40E+00 3.20E+00 1.10E+01 WG 11 L6026-04 8/25/2003 Mn-54

-5.00E-01 1.50E+00 5.70E+00 WG 11 L6026-04 8/25/2003 Zn-65

-4.80E+00 7.90E+00 2.80E+01 WG 11 L6026-04 8/25/2003 Zr-95

-1.50E+00 3.10E+00 1.20E+01 WG 11 L6199-04 9/23/2003 Ba-140 1.40E+00 2.10E+00 7.60E+00 WG 11 L6199-04 9/23/2003 Co-58

-1.40E+00 1.60E+00 5.90E+00 WG 11 L6199-04 9/23/2003 Co-60

-1.00E+00 1.70E+00 6.60E+00 WG 11 L6199-04 9/23/2003 Cs-134 1.40E+00 1.60E+00 5.50E+00 WG 11 L6199-04 9/23/2003 Cs-137

-4.20E+00 1.60E+00 6.20E+00 WG 11 L6199-04 9/23/2003 Fe-59 5.30E+00 3.40E+00 1.10E+01 WG 11 L6199-04 9/23/2003 GR-B 2.56E+00 9.50E-01 2.90E+00 WG 11 L6199-04 9/23/2003 H-3

-2.00E+01 1.30E+02 3.80E+02 WG 11 L6199-04 9/23/2003 I-131

-8.00E-01 2.20E+00 7.60E+00 WG 11 L6199-04 9/23/2003 Mn-54

-3.40E+00 1.60E+00 6.20E+00 WG 11 L6199-04 9/23/2003 Zn-65 1.23E+01 8.00E+00 2.60E+01 WG 11 L6199-04 9/23/2003 Zr-95

-1.00E-01 2.60E+00 9.30E+00 WG 11 L6442-04 10/29/2003 Ba-140 9.00E-01 2.00E+00 7.30E+00 WG 11 L6442-04 10/29/2003 Co-58

-2.30E+00 1.70E+00 6.60E+00 WG 11 L6442-04 10/29/2003 Co-60

-3.00E-01 1.40E+00 5.30E+00 WG 11 L6442-04 10/29/2003 Cs-134 0.00E+00 1.40E+00 5.10E+00 WG 11 L6442-04 10/29/2003 Cs-137

-3.40E+00 1.40E+00 5.90E+00 WG 11 L6442-04 10/29/2003 Fe-59

-2.30E+00 3.40E+00 1.40E+01 WG 11 L6442-04 10/29/2003 GR-B 5.20E+00 1.10E+00 3.00E+00 WG 11 L6442-04 10/29/2003 H-3 0.00E+00 8.40E+01 2.70E+02 WG 11 L6442-04 10/29/2003 I-131 9.00E-01 3.50E+00 1.20E+01 WG 11 L6442-04 10/29/2003 Mn-54

-1.20E+00 1.40E+00 5.40E+00 WG 11 L6442-04 10/29/2003 Zn-65 4.10E+00 6.90E+00 2.30E+01 WG 11 L6442-04 10/29/2003 Zr-95 1.10E+00 2.60E+00 9.30E+00 WG 11 L6584-04 12/1/2003 Ba-140 8.60E+00 5.80E+00 1.90E+01 WG 11 L6584-04 12/1/2003 Co-58 2.00E-01 1.90E+00 6.90E+00 WG 11 L6584-04 12/1/2003 Co-60

-1.40E+00 2.10E+00 8.20E+00 WG 11 L6584-04 12/1/2003 Cs-134

-2.20E+00 1.90E+00 7.40E+00 WG 11 L6584-04 12/1/2003 Cs-137

-2.00E+00 2.00E+00 7.50E+00 WG 11 L6584-04 12/1/2003 Fe-59 6.50E+00 6.50E+00 2.30E+01 WG 11 L6584-04 12/1/2003 GR-B 1.56E+00 9.10E-01 2.90E+00 WG 11 L6584-04 12/1/2003 H-3

-2.00E+02 9.20E+01 3.00E+02 WG 11 L6584-04 12/1/2003 I-131 0.00E+00 7.00E+00 2.50E+01 WG 11 L6584-04 12/1/2003 Mn-54

-2.80E+00 1.60E+00 6.70E+00 WG 11 L6584-04 12/1/2003 Zn-65

-5.00E+00 3.90E+00 1.60E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-22 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 11 L6584-04 12/1/2003 Zr-95

-6.90E+00 3.60E+00 1.40E+01 WG 11 L6732-04 12/29/2003 Ba-140 3.10E+00 4.90E+00 1.90E+01 WG 11 L6732-04 12/29/2003 Co-58

-1.40E+00 2.10E+00 8.80E+00 WG 11 L6732-04 12/29/2003 Co-60 1.80E+00 2.20E+00 8.00E+00 WG 11 L6732-04 12/29/2003 Cs-134 9.00E-01 1.80E+00 7.00E+00 WG 11 L6732-04 12/29/2003 Cs-137

-1.70E+00 2.10E+00 8.80E+00 WG 11 L6732-04 12/29/2003 Fe-59 5.30E+00 5.30E+00 1.90E+01 WG 11 L6732-04 12/29/2003 GR-B 4.34E+00 8.60E-01 2.30E+00 WG 11 L6732-04 12/29/2003 H-3 5.00E+01 1.10E+02 3.40E+02 WG 11 L6732-04 12/29/2003 I-131 5.90E+00 6.80E+00 2.30E+01 WG 11 L6732-04 12/29/2003 Mn-54 5.00E-01 1.80E+00 7.10E+00 WG 11 L6732-04 12/29/2003 Zn-65

-1.59E+01 6.10E+00 2.80E+01 WG 11 L6732-04 12/29/2003 Zr-95 4.70E+00 3.80E+00 1.30E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-23 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 12 L4583-05 1/1/2003 Ba-140

-1.80E+00 1.50E+00 7.70E+00 WG 12 L4583-05 1/1/2003 Co-58

-7.00E-01 1.10E+00 4.50E+00 WG 12 L4583-05 1/1/2003 Co-60

-2.50E+00 1.60E+00 6.80E+00 WG 12 L4583-05 1/1/2003 Cs-134

-1.80E+00 1.40E+00 5.80E+00 WG 12 L4583-05 1/1/2003 Cs-137 2.00E-01 1.30E+00 5.00E+00 WG 12 L4583-05 1/1/2003 Fe-59

-1.80E+00 2.90E+00 1.20E+01 WG 12 L4583-05 1/1/2003 GR-B 6.00E+00 1.20E+00 3.30E+00 WG 12 L4583-05 1/1/2003 H-3

-8.00E+01 1.20E+02 3.70E+02 WG 12 L4583-05 1/1/2003 I-131 2.80E+00 2.50E+00 8.50E+00 WG 12 L4583-05 1/1/2003 Mn-54 1.00E+00 1.40E+00 4.90E+00 WG 12 L4583-05 1/1/2003 Zn-65

-7.50E+00 2.90E+00 1.40E+01 WG 12 L4583-05 1/1/2003 Zr-95

-1.90E+00 1.80E+00 8.00E+00 WG 12 L4795-05 1/29/2003 Ba-140

-3.80E+00 3.40E+00 1.70E+01 WG 12 L4795-05 1/29/2003 Co-58

-3.00E+00 1.90E+00 9.00E+00 WG 12 L4795-05 1/29/2003 Co-60 3.20E+00 2.00E+00 6.60E+00 WG 12 L4795-05 1/29/2003 Cs-134

-4.00E-01 2.20E+00 9.10E+00 WG 12 L4795-05 1/29/2003 Cs-137 1.00E+00 2.00E+00 7.60E+00 WG 12 L4795-05 1/29/2003 Fe-59 2.60E+00 4.40E+00 1.70E+01 WG 12 L4795-05 1/29/2003 GR-B 5.80E+00 1.20E+00 3.10E+00 WG 12 L4795-05 1/29/2003 H-3 5.00E+01 1.20E+02 3.50E+02 WG 12 L4795-05 1/29/2003 I-131

-4.10E+00 3.50E+00 1.50E+01 WG 12 L4795-05 1/29/2003 Mn-54 0.00E+00 2.00E+00 8.10E+00 WG 12 L4795-05 1/29/2003 Zn-65 2.60E+00 1.80E+00 3.50E+00 WG 12 L4795-05 1/29/2003 Zr-95

-4.40E+00 3.10E+00 1.50E+01 WG 12 L4971-05 2/25/2003 Ba-140

-2.30E+00 1.10E+00 4.80E+00 WG 12 L4971-05 2/25/2003 Co-58

-1.95E+00 8.10E-01 3.30E+00 WG 12 L4971-05 2/25/2003 Co-60

-3.80E-01 7.60E-01 3.00E+00 WG 12 L4971-05 2/25/2003 Cs-134 7.70E-01 8.80E-01 3.00E+00 WG 12 L4971-05 2/25/2003 Cs-137

-1.90E-01 9.10E-01 3.30E+00 WG 12 L4971-05 2/25/2003 Fe-59 1.70E+00 1.70E+00 5.90E+00 WG 12 L4971-05 2/25/2003 GR-B 6.50E+00 1.20E+00 2.90E+00 WG 12 L4971-05 2/25/2003 H-3

-2.00E+00 9.00E+01 2.80E+02 WG 12 L4971-05 2/25/2003 I-131 2.30E+00 1.70E+00 5.70E+00 WG 12 L4971-05 2/25/2003 Mn-54

-2.90E-01 8.40E-01 3.10E+00 WG 12 L4971-05 2/25/2003 Zn-65

-1.90E+00 2.00E+00 7.60E+00 WG 12 L4971-05 2/25/2003 Zr-95 1.00E+00 1.40E+00 5.00E+00 WG 12 L5212-05 4/2/2003 Ba-140 5.60E+00 2.00E+00 5.60E+00 WG 12 L5212-05 4/2/2003 Co-58

-3.40E-01 8.70E-01 3.40E+00 WG 12 L5212-05 4/2/2003 Co-60 1.77E+00 8.90E-01 2.70E+00 WG 12 L5212-05 4/2/2003 Cs-134 1.80E+00 1.20E+00 4.00E+00 WG 12 L5212-05 4/2/2003 Cs-137

-5.20E-01 9.20E-01 3.60E+00 WG 12 L5212-05 4/2/2003 Fe-59 1.00E-01 2.20E+00 8.20E+00 WG 12 L5212-05 4/2/2003 GR-B 5.60E+00 1.10E+00 2.90E+00 WG 12 L5212-05 4/2/2003 H-3 0.00E+00 8.90E+01 2.80E+02 WG 12 L5212-05 4/2/2003 I-131

-2.00E+00 2.00E+00 7.40E+00 WG 12 L5212-05 4/2/2003 Mn-54 6.50E-01 8.30E-01 3.00E+00 WG 12 L5212-05 4/2/2003 Zn-65

-3.70E+00 2.40E+00 9.80E+00 WG 12 L5212-05 4/2/2003 Zr-95 9.00E-01 1.60E+00 5.90E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-24 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 12 L5373-06 4/29/2003 Ba-140

-8.00E-01 1.70E+00 7.20E+00 WG 12 L5373-06 4/29/2003 Co-58 0.00E+00 1.30E+00 4.90E+00 WG 12 L5373-06 4/29/2003 Co-60 4.00E-01 1.20E+00 4.60E+00 WG 12 L5373-06 4/29/2003 Cs-134 3.00E-01 1.20E+00 4.60E+00 WG 12 L5373-06 4/29/2003 Cs-137 1.00E+00 1.30E+00 4.80E+00 WG 12 L5373-06 4/29/2003 Fe-59 3.60E+00 2.40E+00 8.00E+00 WG 12 L5373-06 4/29/2003 GR-B 5.70E+00 1.20E+00 3.10E+00 WG 12 L5373-06 4/29/2003 H-3 2.00E+01 9.70E+01 3.00E+02 WG 12 L5373-06 4/29/2003 I-131

-1.20E+00 1.80E+00 6.70E+00 WG 12 L5373-06 4/29/2003 Mn-54

-3.00E-01 1.10E+00 4.50E+00 WG 12 L5373-06 4/29/2003 Zn-65

-4.00E-01 3.40E+00 1.30E+01 WG 12 L5373-06 4/29/2003 Zr-95 4.40E+00 2.40E+00 7.70E+00 WG 12 L5530-05 5/27/2003 Ba-140 3.30E+00 2.60E+00 8.80E+00 WG 12 L5530-05 5/27/2003 Co-58 6.00E-01 1.20E+00 4.50E+00 WG 12 L5530-05 5/27/2003 Co-60 1.30E+00 2.00E+00 7.10E+00 WG 12 L5530-05 5/27/2003 Cs-134 1.30E+00 1.40E+00 5.00E+00 WG 12 L5530-05 5/27/2003 Cs-137 7.00E-01 1.40E+00 5.10E+00 WG 12 L5530-05 5/27/2003 Fe-59 0.00E+00 2.60E+00 1.00E+01 WG 12 L5530-05 5/27/2003 GR-B 4.90E+00 1.20E+00 3.20E+00 WG 12 L5530-05 5/27/2003 H-3

-1.05E+02 8.20E+01 2.60E+02 WG 12 L5530-05 5/27/2003 I-131

-3.40E+00 2.40E+00 9.20E+00 WG 12 L5530-05 5/27/2003 Mn-54 1.00E-01 1.10E+00 4.30E+00 WG 12 L5530-05 5/27/2003 Zn-65 3.10E+00 2.90E+00 9.90E+00 WG 12 L5530-05 5/27/2003 Zr-95

-3.20E+00 2.40E+00 9.90E+00 WG 12 L5724-05 6/30/2003 Ba-140 2.50E+00 1.70E+00 5.60E+00 WG 12 L5724-05 6/30/2003 Co-58

-9.90E-01 9.00E-01 3.60E+00 WG 12 L5724-05 6/30/2003 Co-60 4.00E-01 1.00E+00 3.80E+00 WG 12 L5724-05 6/30/2003 Cs-134

-1.10E+00 1.10E+00 4.20E+00 WG 12 L5724-05 6/30/2003 Cs-137

-5.00E-01 9.70E-01 3.70E+00 WG 12 L5724-05 6/30/2003 Fe-59 2.70E+00 1.90E+00 6.50E+00 WG 12 L5724-05 6/30/2003 GR-B 8.20E+00 1.40E+00 3.40E+00 WG 12 L5724-05 6/30/2003 H-3 1.01E+02 8.30E+01 2.60E+02 WG 12 L5724-05 6/30/2003 I-131

-1.00E+00 1.60E+00 5.80E+00 WG 12 L5724-05 6/30/2003 Mn-54 1.76E+00 9.10E-01 2.90E+00 WG 12 L5724-05 6/30/2003 Zn-65

-4.60E+00 2.20E+00 9.20E+00 WG 12 L5724-05 6/30/2003 Zr-95

-1.20E+00 1.70E+00 6.40E+00 WG 12 L5906-06 7/29/2003 Ba-140 7.00E-01 1.10E+00 3.80E+00 WG 12 L5906-06 7/29/2003 Co-58

-7.70E-01 4.70E-01 1.70E+00 WG 12 L5906-06 7/29/2003 Co-60 3.60E-01 4.70E-01 1.60E+00 WG 12 L5906-06 7/29/2003 Cs-134

-1.90E-01 5.10E-01 1.80E+00 WG 12 L5906-06 7/29/2003 Cs-137

-5.00E-01 5.30E-01 1.90E+00 WG 12 L5906-06 7/29/2003 Fe-59 2.30E+00 1.10E+00 3.50E+00 WG 12 L5906-06 7/29/2003 GR-B 8.00E+00 1.40E+00 3.50E+00 WG 12 L5906-06 7/29/2003 H-3 2.60E+02 1.30E+02 3.70E+02 WG 12 L5906-06 7/29/2003 I-131

-9.00E-01 1.70E+00 6.00E+00 WG 12 L5906-06 7/29/2003 Mn-54 3.00E-02 4.90E-01 1.70E+00 WG 12 L5906-06 7/29/2003 Zn-65

-8.00E-01 1.10E+00 3.90E+00 WG 12 L5906-06 7/29/2003 Zr-95 5.80E-01 8.50E-01 2.90E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-25 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 12 L6026-05 8/25/2003 Ba-140 4.50E+00 3.70E+00 1.30E+01 WG 12 L6026-05 8/25/2003 Co-58

-1.90E+00 1.90E+00 7.80E+00 WG 12 L6026-05 8/25/2003 Co-60 1.90E+00 1.50E+00 5.10E+00 WG 12 L6026-05 8/25/2003 Cs-134 1.50E+00 1.90E+00 7.00E+00 WG 12 L6026-05 8/25/2003 Cs-137

-7.00E-01 1.20E+00 5.10E+00 WG 12 L6026-05 8/25/2003 Fe-59

-4.00E+00 4.50E+00 2.00E+01 WG 12 L6026-05 8/25/2003 GR-B 9.50E+00 1.60E+00 3.80E+00 WG 12 L6026-05 8/25/2003 H-3 3.60E+02 1.30E+02 3.70E+02 WG 12 L6026-05 8/25/2003 I-131 2.00E+00 2.70E+00 9.70E+00 WG 12 L6026-05 8/25/2003 Mn-54

-2.00E-01 1.70E+00 6.60E+00 WG 12 L6026-05 8/25/2003 Zn-65

-9.90E+00 4.30E+00 2.00E+01 WG 12 L6026-05 8/25/2003 Zr-95

-5.00E-01 3.40E+00 1.30E+01 WG 12 L6199-05 9/23/2003 Ba-140 0.00E+00 1.60E+00 6.20E+00 WG 12 L6199-05 9/23/2003 Co-58

-1.00E+00 1.20E+00 4.70E+00 WG 12 L6199-05 9/23/2003 Co-60

-5.00E-01 1.20E+00 5.00E+00 WG 12 L6199-05 9/23/2003 Cs-134 2.00E-01 1.30E+00 4.80E+00 WG 12 L6199-05 9/23/2003 Cs-137

-1.30E+00 1.20E+00 4.90E+00 WG 12 L6199-05 9/23/2003 Fe-59

-1.20E+00 2.90E+00 1.20E+01 WG 12 L6199-05 9/23/2003 GR-B 6.30E+00 1.20E+00 3.30E+00 WG 12 L6199-05 9/23/2003 H-3 1.40E+02 1.30E+02 3.80E+02 WG 12 L6199-05 9/23/2003 I-131 2.00E-01 1.80E+00 6.60E+00 WG 12 L6199-05 9/23/2003 Mn-54 0.00E+00 1.10E+00 4.30E+00 WG 12 L6199-05 9/23/2003 Zn-65

-2.10E+00 3.10E+00 1.20E+01 WG 12 L6199-05 9/23/2003 Zr-95 1.80E+00 2.20E+00 7.60E+00 WG 12 L6442-05 10/29/2003 Ba-140

-2.00E+00 3.10E+00 1.40E+01 WG 12 L6442-05 10/29/2003 Co-58

-3.30E+00 1.90E+00 8.40E+00 WG 12 L6442-05 10/29/2003 Co-60

-3.50E+00 2.30E+00 1.00E+01 WG 12 L6442-05 10/29/2003 Cs-134

-1.00E-01 1.80E+00 7.30E+00 WG 12 L6442-05 10/29/2003 Cs-137 1.10E+00 1.10E+00 4.10E+00 WG 12 L6442-05 10/29/2003 Fe-59 0.00E+00 2.10E+00 1.10E+01 WG 12 L6442-05 10/29/2003 GR-B 7.10E+00 1.30E+00 3.20E+00 WG 12 L6442-05 10/29/2003 H-3 2.40E+01 8.40E+01 2.70E+02 WG 12 L6442-05 10/29/2003 I-131 3.70E+00 3.10E+00 1.10E+01 WG 12 L6442-05 10/29/2003 Mn-54 9.00E-01 1.40E+00 5.20E+00 WG 12 L6442-05 10/29/2003 Zn-65

-3.00E+00 3.00E+00 1.40E+01 WG 12 L6442-05 10/29/2003 Zr-95 5.80E+00 3.30E+00 1.00E+01 WG 12 L6584-05 11/28/2003 Ba-140

-1.70E+00 4.60E+00 1.80E+01 WG 12 L6584-05 11/28/2003 Co-58

-7.00E-01 1.90E+00 6.90E+00 WG 12 L6584-05 11/28/2003 Co-60 1.90E+00 1.70E+00 5.90E+00 WG 12 L6584-05 11/28/2003 Cs-134 7.00E-01 1.70E+00 6.10E+00 WG 12 L6584-05 11/28/2003 Cs-137 1.70E+00 1.60E+00 5.50E+00 WG 12 L6584-05 11/28/2003 Fe-59 6.00E-01 4.80E+00 1.80E+01 WG 12 L6584-05 11/28/2003 GR-B 8.00E+00 1.20E+00 3.00E+00 WG 12 L6584-05 11/28/2003 H-3 4.00E+01 9.40E+01 3.00E+02 WG 12 L6584-05 11/28/2003 I-131 1.32E+01 8.40E+00 2.80E+01 WG 12 L6584-05 11/28/2003 Mn-54 6.00E-01 1.80E+00 6.30E+00 WG 12 L6584-05 11/28/2003 Zn-65 1.30E+01 6.50E+00 2.10E+01 WG 12 L6584-05 11/28/2003 Zr-95 1.30E+00 3.40E+00 1.20E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-26 Ground Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WG 12 L6732-05 12/29/2003 Ba-140 2.80E+00 3.90E+00 1.50E+01 WG 12 L6732-05 12/29/2003 Co-58 1.00E+00 2.00E+00 7.50E+00 WG 12 L6732-05 12/29/2003 Co-60 2.10E+00 2.50E+00 8.90E+00 WG 12 L6732-05 12/29/2003 Cs-134 0.00E+00 1.80E+00 7.30E+00 WG 12 L6732-05 12/29/2003 Cs-137

-6.00E-01 1.90E+00 7.50E+00 WG 12 L6732-05 12/29/2003 Fe-59 2.20E+00 6.90E+00 2.70E+01 WG 12 L6732-05 12/29/2003 GR-B 9.00E+00 1.30E+00 3.10E+00 WG 12 L6732-05 12/29/2003 H-3 2.60E+02 1.10E+02 3.30E+02 WG 12 L6732-05 12/29/2003 I-131

-8.50E+00 6.20E+00 2.50E+01 WG 12 L6732-05 12/29/2003 Mn-54

-3.60E+00 1.80E+00 8.40E+00 WG 12 L6732-05 12/29/2003 Zn-65

-2.20E+00 4.20E+00 1.80E+01 WG 12 L6732-05 12/29/2003 Zr-95 3.60E+00 3.80E+00 1.40E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-27 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 11 L4583-01 1/1/2003 Ba-140 7.00E-01 1.60E+00 6.00E+00 WR 11 L4583-01 1/1/2003 Co-58 6.20E-01 8.50E-01 3.00E+00 WR 11 L4583-01 1/1/2003 Co-60 0.00E+00 1.10E+00 4.10E+00 WR 11 L4583-01 1/1/2003 Cs-134

-1.00E-01 1.10E+00 4.10E+00 WR 11 L4583-01 1/1/2003 Cs-137 1.70E+00 1.20E+00 3.80E+00 WR 11 L4583-01 1/1/2003 Fe-59 4.00E-01 2.20E+00 8.00E+00 WR 11 L4583-01 1/1/2003 GR-B 2.21E+00 9.30E-01 2.90E+00 WR 11 L4583-01 1/1/2003 H-3 5.00E+01 4.30E+02 1.30E+03 WR 11 L4583-01 1/1/2003 I-131 1.80E+00 1.90E+00 6.60E+00 WR 11 L4583-01 1/1/2003 Mn-54

-1.70E+00 1.10E+00 4.40E+00 WR 11 L4583-01 1/1/2003 Zn-65

-6.90E+00 2.30E+00 1.10E+01 WR 11 L4583-01 1/1/2003 Zr-95

-2.70E+00 1.70E+00 7.10E+00 WR 11 L4884-01 1/1/2003 H-3 9.50E+02 4.70E+02 1.30E+03 WR 11 L4795-01 1/29/2003 Ba-140 2.90E+00 1.70E+00 5.50E+00 WR 11 L4795-01 1/29/2003 Co-58

-1.33E+00 8.90E-01 3.80E+00 WR 11 L4795-01 1/29/2003 Co-60 4.50E-01 9.10E-01 3.40E+00 WR 11 L4795-01 1/29/2003 Cs-134 9.00E-01 1.00E+00 3.60E+00 WR 11 L4795-01 1/29/2003 Cs-137

-8.00E-01 1.10E+00 4.10E+00 WR 11 L4795-01 1/29/2003 Fe-59 8.00E-01 1.70E+00 6.40E+00 WR 11 L4795-01 1/29/2003 GR-B 1.34E+00 8.40E-01 2.70E+00 WR 11 L4795-01 1/29/2003 H-3 2.30E+02 4.30E+02 1.30E+03 WR 11 L4795-01 1/29/2003 I-131 2.10E+00 2.00E+00 6.70E+00 WR 11 L4795-01 1/29/2003 Mn-54 5.00E-01 1.10E+00 3.90E+00 WR 11 L4795-01 1/29/2003 Zn-65

-4.50E+00 2.50E+00 1.00E+01 WR 11 L4795-01 1/29/2003 Zr-95

-6.00E-01 1.90E+00 7.30E+00 WR 11 L4971-01 2/25/2003 Ba-140 2.50E+00 1.80E+00 5.90E+00 WR 11 L4971-01 2/25/2003 Co-58

-2.00E-01 1.10E+00 4.00E+00 WR 11 L4971-01 2/25/2003 Co-60

-8.00E-01 1.10E+00 4.30E+00 WR 11 L4971-01 2/25/2003 Cs-134

-7.00E-01 1.00E+00 4.00E+00 WR 11 L4971-01 2/25/2003 Cs-137 5.00E-01 1.10E+00 3.90E+00 WR 11 L4971-01 2/25/2003 Fe-59

-4.30E+00 1.90E+00 8.30E+00 WR 11 L4971-01 2/25/2003 GR-B 2.18E+00 8.90E-01 2.80E+00 WR 11 L4971-01 2/25/2003 H-3 3.20E+02 4.70E+02 1.40E+03 WR 11 L4971-01 2/25/2003 I-131 2.00E-01 1.80E+00 6.50E+00 WR 11 L4971-01 2/25/2003 Mn-54 5.50E-01 9.30E-01 3.30E+00 WR 11 L4971-01 2/25/2003 Zn-65

-4.70E+00 1.90E+00 8.50E+00 WR 11 L4971-01 2/25/2003 Zr-95

-3.50E+00 1.70E+00 7.00E+00 WR 11 L5273-01 2/25/2003 H-3

-7.00E+01 4.50E+02 1.30E+03 WR 11 L5212-01 4/2/2003 Ba-140 2.60E+00 2.00E+00 6.80E+00 WR 11 L5212-01 4/2/2003 Co-58

-1.80E-01 9.40E-01 3.80E+00 WR 11 L5212-01 4/2/2003 Co-60

-9.00E-01 1.20E+00 5.20E+00 WR 11 L5212-01 4/2/2003 Cs-134

-2.70E+00 1.30E+00 5.70E+00 WR 11 L5212-01 4/2/2003 Cs-137 6.00E-01 1.30E+00 4.70E+00 WR 11 L5212-01 4/2/2003 Fe-59

-2.20E+00 2.20E+00 9.60E+00 WR 11 L5212-01 4/2/2003 GR-B 2.39E+00 9.00E-01 2.80E+00 WR 11 L5212-01 4/2/2003 H-3

-5.00E+01 4.70E+02 1.30E+03 WR 11 L5212-01 4/2/2003 I-131 6.00E-01 2.40E+00 8.40E+00 WR 11 L5212-01 4/2/2003 Mn-54 2.00E-01 1.20E+00 4.60E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-28 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 11 L5212-01 4/2/2003 Zn-65

-1.10E+00 2.80E+00 1.10E+01 WR 11 L5212-01 4/2/2003 Zr-95 1.00E-01 2.20E+00 8.40E+00 WR 11 L5373-01 4/29/2003 Ba-140

-2.00E+00 1.70E+00 8.60E+00 WR 11 L5373-01 4/29/2003 Co-58

-1.70E+00 1.40E+00 6.30E+00 WR 11 L5373-01 4/29/2003 Co-60

-8.00E-01 1.50E+00 6.90E+00 WR 11 L5373-01 4/29/2003 Cs-134

-1.50E+00 1.70E+00 7.20E+00 WR 11 L5373-01 4/29/2003 Cs-137 1.80E+00 1.60E+00 5.70E+00 WR 11 L5373-01 4/29/2003 Fe-59

-2.60E+00 2.60E+00 1.20E+01 WR 11 L5373-01 4/29/2003 GR-B 6.70E-01 7.70E-01 2.60E+00 WR 11 L5373-01 4/29/2003 H-3

-7.80E+02 4.60E+02 1.40E+03 WR 11 L5373-01 4/29/2003 I-131 0.00E+00 1.90E+00 7.00E+00 WR 11 L5373-01 4/29/2003 Mn-54 1.50E+00 1.60E+00 5.60E+00 WR 11 L5373-01 4/29/2003 Zn-65

-9.00E-01 2.80E+00 1.20E+01 WR 11 L5373-01 4/29/2003 Zr-95

-4.50E+00 2.80E+00 1.30E+01 WR 11 L5530-01 5/27/2003 Ba-140

-1.90E+00 1.90E+00 8.80E+00 WR 11 L5530-01 5/27/2003 Co-58

-1.30E+00 1.50E+00 6.30E+00 WR 11 L5530-01 5/27/2003 Co-60 0.00E+00 1.90E+00 7.30E+00 WR 11 L5530-01 5/27/2003 Cs-134

-1.80E+00 1.60E+00 6.80E+00 WR 11 L5530-01 5/27/2003 Cs-137

-2.20E+00 1.50E+00 6.40E+00 WR 11 L5530-01 5/27/2003 Fe-59

-1.60E+00 3.30E+00 1.30E+01 WR 11 L5530-01 5/27/2003 GR-B 2.40E-01 7.50E-01 2.70E+00 WR 11 L5530-01 5/27/2003 H-3

-2.60E+02 4.00E+02 1.20E+03 WR 11 L5530-01 5/27/2003 I-131 1.90E+00 2.40E+00 8.50E+00 WR 11 L5530-01 5/27/2003 Mn-54

-2.60E+00 1.40E+00 6.30E+00 WR 11 L5530-01 5/27/2003 Zn-65 1.80E+00 2.90E+00 1.10E+01 WR 11 L5530-01 5/27/2003 Zr-95

-2.30E+00 3.00E+00 1.20E+01 WR 11 L5724-01 6/30/2003 Ba-140 3.30E+00 1.60E+00 4.90E+00 WR 11 L5724-01 6/30/2003 Co-58

-2.80E+00 1.10E+00 4.90E+00 WR 11 L5724-01 6/30/2003 Co-60 0.00E+00 1.20E+00 4.60E+00 WR 11 L5724-01 6/30/2003 Cs-134

-3.00E-01 1.10E+00 4.40E+00 WR 11 L5724-01 6/30/2003 Cs-137 1.60E+00 1.20E+00 3.90E+00 WR 11 L5724-01 6/30/2003 Fe-59 0.00E+00 2.00E+00 7.90E+00 WR 11 L5724-01 6/30/2003 GR-B 1.59E+00 8.30E-01 2.60E+00 WR 11 L5724-01 6/30/2003 H-3 2.10E+02 4.10E+02 1.20E+03 WR 11 L5724-01 6/30/2003 I-131

-3.10E+00 1.90E+00 7.30E+00 WR 11 L5724-01 6/30/2003 Mn-54 2.10E+00 1.20E+00 3.90E+00 WR 11 L5724-01 6/30/2003 Zn-65 0.00E+00 2.90E+00 1.10E+01 WR 11 L5724-01 6/30/2003 Zr-95 2.50E+00 2.10E+00 7.10E+00 WR 11 L5947-01 6/30/2003 H-3 1.70E+02 4.00E+02 1.20E+03 WR 11 L5906-01 7/29/2003 Ba-140

-2.80E+00 2.80E+00 1.20E+01 WR 11 L5906-01 7/29/2003 Co-58

-1.00E+00 1.10E+00 4.70E+00 WR 11 L5906-01 7/29/2003 Co-60

-1.30E+00 1.40E+00 5.80E+00 WR 11 L5906-01 7/29/2003 Cs-134

-3.00E-01 1.30E+00 5.10E+00 WR 11 L5906-01 7/29/2003 Cs-137 6.00E-01 1.20E+00 4.40E+00 WR 11 L5906-01 7/29/2003 Fe-59 1.80E+00 2.80E+00 1.00E+01 WR 11 L5906-01 7/29/2003 GR-B 2.13E+00 8.90E-01 2.70E+00 WR 11 L5906-01 7/29/2003 H-3

-6.00E+02 4.10E+02 1.30E+03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-29 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 11 L5906-01 7/29/2003 I-131 2.80E+00 4.10E+00 1.40E+01 WR 11 L5906-01 7/29/2003 Mn-54 9.00E-01 1.20E+00 4.30E+00 WR 11 L5906-01 7/29/2003 Zn-65

-3.30E+00 2.70E+00 1.10E+01 WR 11 L5906-01 7/29/2003 Zr-95

-3.50E+00 2.10E+00 9.20E+00 WR 11 L6026-01 8/25/2003 Ba-140

-3.80E+00 2.70E+00 1.40E+01 WR 11 L6026-01 8/25/2003 Co-58

-1.10E+00 2.00E+00 8.10E+00 WR 11 L6026-01 8/25/2003 Co-60

-2.70E+00 1.70E+00 8.50E+00 WR 11 L6026-01 8/25/2003 Cs-134 1.20E+00 1.90E+00 7.10E+00 WR 11 L6026-01 8/25/2003 Cs-137 0.00E+00 1.50E+00 5.80E+00 WR 11 L6026-01 8/25/2003 Fe-59 2.90E+00 5.40E+00 2.00E+01 WR 11 L6026-01 8/25/2003 GR-B 1.98E+00 8.70E-01 2.70E+00 WR 11 L6026-01 8/25/2003 H-3 3.20E+02 4.00E+02 1.20E+03 WR 11 L6026-01 8/25/2003 I-131

-5.50E+00 2.80E+00 1.20E+01 WR 11 L6026-01 8/25/2003 Mn-54

-9.00E-01 1.60E+00 6.80E+00 WR 11 L6026-01 8/25/2003 Zn-65

-1.00E+00 3.20E+00 1.40E+01 WR 11 L6026-01 8/25/2003 Zr-95

-8.00E-01 2.80E+00 1.20E+01 WR 11 L6199-01 9/23/2003 Ba-140

-6.00E-01 1.30E+00 5.40E+00 WR 11 L6199-01 9/23/2003 Co-58 2.00E-01 1.10E+00 4.10E+00 WR 11 L6199-01 9/23/2003 Co-60 2.50E+00 1.10E+00 3.30E+00 WR 11 L6199-01 9/23/2003 Cs-134 6.00E-01 1.20E+00 4.20E+00 WR 11 L6199-01 9/23/2003 Cs-137 1.10E+00 1.20E+00 4.00E+00 WR 11 L6199-01 9/23/2003 Fe-59

-6.00E-01 3.30E+00 1.30E+01 WR 11 L6199-01 9/23/2003 GR-B 1.40E+00 8.60E-01 2.80E+00 WR 11 L6199-01 9/23/2003 H-3 8.80E+02 4.20E+02 1.20E+03 WR 11 L6199-01 9/23/2003 I-131

-2.40E+00 1.90E+00 7.30E+00 WR 11 L6199-01 9/23/2003 Mn-54 1.50E+00 1.10E+00 3.70E+00 WR 11 L6199-01 9/23/2003 Zn-65

-6.20E+00 2.90E+00 1.20E+01 WR 11 L6199-01 9/23/2003 Zr-95 7.00E-01 1.60E+00 6.00E+00 WR 11 L6511-01 9/23/2003 H-3 1.30E+02 4.20E+02 1.30E+03 WR 11 L6442-01 10/29/2003 Ba-140 4.50E+00 2.00E+00 2.40E+00 WR 11 L6442-01 10/29/2003 Co-58

-1.10E+00 1.30E+00 5.90E+00 WR 11 L6442-01 10/29/2003 Co-60 7.00E-01 1.90E+00 7.40E+00 WR 11 L6442-01 10/29/2003 Cs-134 1.80E+00 1.50E+00 5.30E+00 WR 11 L6442-01 10/29/2003 Cs-137 1.70E+00 1.70E+00 6.10E+00 WR 11 L6442-01 10/29/2003 Fe-59 3.00E-01 5.20E+00 2.10E+01 WR 11 L6442-01 10/29/2003 GR-B 4.40E+00 1.00E+00 2.80E+00 WR 11 L6442-01 10/29/2003 H-3

-1.10E+02 3.90E+02 1.20E+03 WR 11 L6442-01 10/29/2003 I-131

-2.00E-01 3.10E+00 1.20E+01 WR 11 L6442-01 10/29/2003 Mn-54

-4.00E-01 1.40E+00 5.70E+00 WR 11 L6442-01 10/29/2003 Zn-65

-1.80E+00 3.40E+00 1.50E+01 WR 11 L6442-01 10/29/2003 Zr-95

-1.50E+00 2.80E+00 1.20E+01 WR 11 L6584-01 11/28/2003 Ba-140

-2.30E+00 5.10E+00 2.00E+01 WR 11 L6584-01 11/28/2003 Co-58 1.30E+00 1.70E+00 5.90E+00 WR 11 L6584-01 11/28/2003 Co-60 1.60E+00 1.70E+00 5.70E+00 WR 11 L6584-01 11/28/2003 Cs-134 6.00E-01 1.80E+00 6.30E+00 WR 11 L6584-01 11/28/2003 Cs-137

-9.00E-01 1.70E+00 6.10E+00 WR 11 L6584-01 11/28/2003 Fe-59 5.70E+00 5.50E+00 1.90E+01 WR 11 L6584-01 11/28/2003 GR-B

-2.00E-02 8.00E-01 2.90E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-30 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 11 L6584-01 11/28/2003 H-3

-1.00E+02 4.10E+02 1.30E+03 WR 11 L6584-01 11/28/2003 I-131

-2.30E+00 8.00E+00 2.80E+01 WR 11 L6584-01 11/28/2003 Mn-54

-1.40E+00 1.60E+00 6.10E+00 WR 11 L6584-01 11/28/2003 Zn-65

-2.90E+00 4.10E+00 1.50E+01 WR 11 L6584-01 11/28/2003 Zr-95 8.00E-01 2.90E+00 1.10E+01 WR 11 L6732-01 12/29/2003 Ba-140 1.05E+01 4.10E+00 9.60E+00 WR 11 L6732-01 12/29/2003 Co-58

-1.60E+00 2.00E+00 8.20E+00 WR 11 L6732-01 12/29/2003 Co-60 1.50E+00 2.10E+00 7.60E+00 WR 11 L6732-01 12/29/2003 Cs-134 1.00E-01 1.90E+00 7.50E+00 WR 11 L6732-01 12/29/2003 Cs-137

-2.10E+00 2.10E+00 8.70E+00 WR 11 L6732-01 12/29/2003 Fe-59

-4.50E+00 5.60E+00 2.50E+01 WR 11 L6732-01 12/29/2003 GR-B 5.70E-01 6.80E-01 2.30E+00 WR 11 L6732-01 12/29/2003 H-3

-5.60E+02 3.00E+02 1.00E+03 WR 11 L6732-01 12/29/2003 I-131 7.00E+00 5.10E+00 1.70E+01 WR 11 L6732-01 12/29/2003 Mn-54

-8.00E-01 1.80E+00 7.30E+00 WR 11 L6732-01 12/29/2003 Zn-65

-4.20E+00 4.70E+00 2.00E+01 WR 11 L6732-01 12/29/2003 Zr-95 6.00E-01 2.60E+00 1.00E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-31 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 21 L4583-02 1/1/2003 Ba-140 6.00E-01 1.40E+00 5.30E+00 WR 21 L4583-02 1/1/2003 Co-58

-1.51E+00 8.50E-01 3.70E+00 WR 21 L4583-02 1/1/2003 Co-60 1.17E+00 9.50E-01 3.20E+00 WR 21 L4583-02 1/1/2003 Cs-134

-7.90E-01 9.30E-01 3.80E+00 WR 21 L4583-02 1/1/2003 Cs-137 7.00E-01 1.00E+00 3.60E+00 WR 21 L4583-02 1/1/2003 Fe-59

-5.60E+00 2.00E+00 9.10E+00 WR 21 L4583-02 1/1/2003 GR-B 8.90E-01 8.40E-01 2.80E+00 WR 21 L4583-02 1/1/2003 H-3

-6.70E+02 4.10E+02 1.30E+03 WR 21 L4583-02 1/1/2003 I-131 9.00E-01 2.00E+00 7.00E+00 WR 21 L4583-02 1/1/2003 Mn-54 1.75E+00 9.90E-01 3.20E+00 WR 21 L4583-02 1/1/2003 Zn-65

-4.20E+00 2.20E+00 9.30E+00 WR 21 L4583-02 1/1/2003 Zr-95

-1.20E+00 1.90E+00 7.40E+00 WR 21 L4884-02 1/1/2003 H-3 3.10E+02 4.60E+02 1.30E+03 WR 21 L4795-02 1/29/2003 Ba-140 1.20E+00 2.10E+00 7.80E+00 WR 21 L4795-02 1/29/2003 Co-58 2.00E-01 1.20E+00 4.70E+00 WR 21 L4795-02 1/29/2003 Co-60 1.50E+00 1.20E+00 4.20E+00 WR 21 L4795-02 1/29/2003 Cs-134 2.00E-01 1.40E+00 5.10E+00 WR 21 L4795-02 1/29/2003 Cs-137

-1.10E+00 1.70E+00 6.40E+00 WR 21 L4795-02 1/29/2003 Fe-59

-1.90E+00 3.00E+00 1.20E+01 WR 21 L4795-02 1/29/2003 GR-B 1.91E+00 9.50E-01 3.10E+00 WR 21 L4795-02 1/29/2003 H-3

-9.00E+01 4.20E+02 1.30E+03 WR 21 L4795-02 1/29/2003 I-131

-1.90E+00 2.30E+00 8.90E+00 WR 21 L4795-02 1/29/2003 Mn-54

-8.00E-01 1.50E+00 5.80E+00 WR 21 L4795-02 1/29/2003 Zn-65 0.00E+00 2.80E+00 1.10E+01 WR 21 L4795-02 1/29/2003 Zr-95

-8.00E-01 2.30E+00 9.00E+00 WR 21 L4971-02 2/25/2003 Ba-140 4.00E-01 1.80E+00 6.80E+00 WR 21 L4971-02 2/25/2003 Co-58 6.00E-01 1.10E+00 3.80E+00 WR 21 L4971-02 2/25/2003 Co-60 5.00E-01 1.30E+00 4.70E+00 WR 21 L4971-02 2/25/2003 Cs-134

-6.00E-01 1.30E+00 4.90E+00 WR 21 L4971-02 2/25/2003 Cs-137

-9.00E-01 1.30E+00 4.80E+00 WR 21 L4971-02 2/25/2003 Fe-59

-4.00E-01 2.60E+00 9.80E+00 WR 21 L4971-02 2/25/2003 GR-B 2.24E+00 8.80E-01 2.70E+00 WR 21 L4971-02 2/25/2003 H-3 1.00E+02 4.40E+02 1.30E+03 WR 21 L4971-02 2/25/2003 I-131 3.00E-01 1.70E+00 6.30E+00 WR 21 L4971-02 2/25/2003 Mn-54

-1.60E+00 1.00E+00 4.30E+00 WR 21 L4971-02 2/25/2003 Zn-65 9.00E-01 2.50E+00 9.20E+00 WR 21 L4971-02 2/25/2003 Zr-95 1.50E+00 2.10E+00 7.50E+00 WR 21 L5273-02 2/25/2003 H-3

-2.40E+02 4.30E+02 1.30E+03 WR 21 L5212-02 4/2/2003 Ba-140 6.00E-01 2.00E+00 7.80E+00 WR 21 L5212-02 4/2/2003 Co-58 8.00E-01 1.10E+00 4.10E+00 WR 21 L5212-02 4/2/2003 Co-60

-1.40E+00 1.30E+00 5.90E+00 WR 21 L5212-02 4/2/2003 Cs-134

-1.40E+00 1.40E+00 5.70E+00 WR 21 L5212-02 4/2/2003 Cs-137 2.00E-01 1.00E+00 3.80E+00 WR 21 L5212-02 4/2/2003 Fe-59

-2.50E+00 2.90E+00 1.20E+01 WR 21 L5212-02 4/2/2003 GR-B 2.37E+00 8.20E-01 2.40E+00 WR 21 L5212-02 4/2/2003 H-3 1.00E+01 4.50E+02 1.30E+03 WR 21 L5212-02 4/2/2003 I-131 6.00E-01 2.20E+00 7.80E+00 WR 21 L5212-02 4/2/2003 Mn-54 1.10E+00 1.40E+00 4.90E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-32 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 21 L5212-02 4/2/2003 Zn-65

-2.50E+00 2.70E+00 1.20E+01 WR 21 L5212-02 4/2/2003 Zr-95 4.20E+00 2.00E+00 6.00E+00 WR 21 L5373-02 4/29/2003 Ba-140

-5.40E+00 2.50E+00 1.30E+01 WR 21 L5373-02 4/29/2003 Co-58 3.30E+00 1.70E+00 5.10E+00 WR 21 L5373-02 4/29/2003 Co-60 2.70E+00 2.10E+00 7.20E+00 WR 21 L5373-02 4/29/2003 Cs-134 8.00E-01 1.70E+00 6.60E+00 WR 21 L5373-02 4/29/2003 Cs-137 5.00E-01 1.60E+00 6.30E+00 WR 21 L5373-02 4/29/2003 Fe-59

-2.30E+00 4.30E+00 1.80E+01 WR 21 L5373-02 4/29/2003 GR-B 2.30E+00 9.00E-01 2.70E+00 WR 21 L5373-02 4/29/2003 H-3 2.00E+01 4.60E+02 1.40E+03 WR 21 L5373-02 4/29/2003 I-131

-5.00E-01 2.00E+00 7.80E+00 WR 21 L5373-02 4/29/2003 Mn-54

-1.60E+00 1.90E+00 8.30E+00 WR 21 L5373-02 4/29/2003 Zn-65 1.20E+00 2.80E+00 1.20E+01 WR 21 L5373-02 4/29/2003 Zr-95 1.00E-01 3.10E+00 1.20E+01 WR 21 L5530-02 5/27/2003 Ba-140 4.00E-01 1.90E+00 7.70E+00 WR 21 L5530-02 5/27/2003 Co-58

-1.00E+00 1.40E+00 5.80E+00 WR 21 L5530-02 5/27/2003 Co-60 0.00E+00 1.30E+00 5.50E+00 WR 21 L5530-02 5/27/2003 Cs-134

-1.40E+00 1.50E+00 6.30E+00 WR 21 L5530-02 5/27/2003 Cs-137 1.50E+00 1.70E+00 5.90E+00 WR 21 L5530-02 5/27/2003 Fe-59 1.50E+00 3.10E+00 1.20E+01 WR 21 L5530-02 5/27/2003 GR-B 2.32E+00 8.60E-01 2.60E+00 WR 21 L5530-02 5/27/2003 H-3

-8.00E+01 4.40E+02 1.30E+03 WR 21 L5530-02 5/27/2003 I-131

-6.10E+00 2.80E+00 1.10E+01 WR 21 L5530-02 5/27/2003 Mn-54

-1.50E+00 1.20E+00 5.30E+00 WR 21 L5530-02 5/27/2003 Zn-65

-5.00E+00 3.80E+00 1.60E+01 WR 21 L5530-02 5/27/2003 Zr-95

-4.90E+00 2.40E+00 1.10E+01 WR 21 L5724-02 6/30/2003 Ba-140 6.00E-01 1.90E+00 7.40E+00 WR 21 L5724-02 6/30/2003 Co-58 1.80E+00 1.30E+00 4.30E+00 WR 21 L5724-02 6/30/2003 Co-60 2.40E+00 1.50E+00 4.70E+00 WR 21 L5724-02 6/30/2003 Cs-134

-1.70E+00 1.50E+00 6.10E+00 WR 21 L5724-02 6/30/2003 Cs-137

-1.20E+00 1.40E+00 5.60E+00 WR 21 L5724-02 6/30/2003 Fe-59 2.50E+00 2.90E+00 1.00E+01 WR 21 L5724-02 6/30/2003 GR-B 1.21E+00 8.20E-01 2.70E+00 WR 21 L5724-02 6/30/2003 H-3

-1.60E+02 4.00E+02 1.20E+03 WR 21 L5724-02 6/30/2003 I-131 2.90E+00 2.30E+00 7.80E+00 WR 21 L5724-02 6/30/2003 Mn-54

-2.50E-01 9.50E-01 3.90E+00 WR 21 L5724-02 6/30/2003 Zn-65

-4.40E+00 3.00E+00 1.30E+01 WR 21 L5724-02 6/30/2003 Zr-95

-2.00E+00 2.60E+00 1.00E+01 WR 21 L5947-02 6/30/2003 H-3 1.40E+02 4.00E+02 1.20E+03 WR 21 L5906-02 7/29/2003 Ba-140 2.40E+00 3.40E+00 1.20E+01 WR 21 L5906-02 7/29/2003 Co-58 2.00E-01 1.60E+00 5.80E+00 WR 21 L5906-02 7/29/2003 Co-60

-2.10E+00 1.50E+00 6.20E+00 WR 21 L5906-02 7/29/2003 Cs-134 4.20E+00 1.50E+00 4.40E+00 WR 21 L5906-02 7/29/2003 Cs-137

-3.00E+00 1.40E+00 5.60E+00 WR 21 L5906-02 7/29/2003 Fe-59

-2.50E+00 3.80E+00 1.40E+01 WR 21 L5906-02 7/29/2003 GR-B 2.51E+00 8.90E-01 2.60E+00 WR 21 L5906-02 7/29/2003 H-3

-2.00E+02 4.00E+02 1.20E+03 WR 21 L5906-02 7/29/2003 I-131

-1.00E-01 4.30E+00 1.50E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-33 SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 21 L5906-02 7/29/2003 Mn-54 6.00E-01 1.60E+00 5.70E+00 WR 21 L5906-02 7/29/2003 Zn-65

-2.20E+00 8.30E+00 2.90E+01 WR 21 L5906-02 7/29/2003 Zr-95

-1.30E+00 2.80E+00 1.10E+01 WR 21 L6026-02 8/25/2003 Ba-140

-1.30E+00 2.90E+00 1.20E+01 WR 21 L6026-02 8/25/2003 Co-58

-1.20E+00 1.10E+00 4.80E+00 WR 21 L6026-02 8/25/2003 Co-60

-1.17E+00 8.70E-01 4.70E+00 WR 21 L6026-02 8/25/2003 Cs-134

-3.20E+00 1.60E+00 7.20E+00 WR 21 L6026-02 8/25/2003 Cs-137 0.00E+00 1.50E+00 5.80E+00 WR 21 L6026-02 8/25/2003 Fe-59

-1.00E+00 3.90E+00 1.60E+01 WR 21 L6026-02 8/25/2003 GR-B 3.15E+00 9.70E-01 2.80E+00 WR 21 L6026-02 8/25/2003 H-3

-4.00E+01 4.00E+02 1.20E+03 WR 21 L6026-02 8/25/2003 I-131

-6.00E-01 2.60E+00 9.90E+00 WR 21 L6026-02 8/25/2003 Mn-54 3.00E-01 1.10E+00 4.30E+00 WR 21 L6026-02 8/25/2003 Zn-65

-1.50E+00 3.10E+00 1.30E+01 WR 21 L6026-02 8/25/2003 Zr-95 0.00E+00 2.70E+00 1.00E+01 WR 21 L6199-02 9/23/2003 Ba-140

-6.00E-01 2.00E+00 8.40E+00 WR 21 L6199-02 9/23/2003 Co-58

-6.00E-01 1.30E+00 5.30E+00 WR 21 L6199-02 9/23/2003 Co-60

-2.60E+00 1.90E+00 8.10E+00 WR 21 L6199-02 9/23/2003 Cs-134 4.00E-01 1.50E+00 5.60E+00 WR 21 L6199-02 9/23/2003 Cs-137

-1.00E-01 1.60E+00 5.90E+00 WR 21 L6199-02 9/23/2003 Fe-59

-7.00E+00 4.20E+00 1.90E+01 WR 21 L6199-02 9/23/2003 GR-B 3.60E-01 8.40E-01 2.90E+00 WR 21 L6199-02 9/23/2003 H-3

-1.10E+02 4.00E+02 1.20E+03 WR 21 L6199-02 9/23/2003 I-131 5.50E+00 2.30E+00 7.00E+00 WR 21 L6199-02 9/23/2003 Mn-54 1.40E+00 1.10E+00 3.80E+00 WR 21 L6199-02 9/23/2003 Zn-65

-8.10E+00 2.90E+00 1.40E+01 WR 21 L6199-02 9/23/2003 Zr-95

-1.30E+00 1.90E+00 8.00E+00 WR 21 L6511-02 9/23/2003 H-3

-6.00E+01 4.10E+02 1.30E+03 WR 21 L6442-02 10/29/2003 Ba-140

-9.00E-01 2.40E+00 1.10E+01 WR 21 L6442-02 10/29/2003 Co-58

-3.50E+00 1.40E+00 7.00E+00 WR 21 L6442-02 10/29/2003 Co-60 2.90E+00 2.00E+00 6.70E+00 WR 21 L6442-02 10/29/2003 Cs-134 9.00E-01 1.70E+00 6.20E+00 WR 21 L6442-02 10/29/2003 Cs-137 2.00E+00 1.70E+00 5.70E+00 WR 21 L6442-02 10/29/2003 Fe-59 1.90E+00 4.90E+00 1.90E+01 WR 21 L6442-02 10/29/2003 GR-B 2.42E+00 9.30E-01 2.80E+00 WR 21 L6442-02 10/29/2003 H-3 9.00E+01 4.10E+02 1.20E+03 WR 21 L6442-02 10/29/2003 I-131

-3.40E+00 3.10E+00 1.20E+01 WR 21 L6442-02 10/29/2003 Mn-54 1.30E+00 1.20E+00 4.40E+00 WR 21 L6442-02 10/29/2003 Zn-65 3.60E+00 3.10E+00 1.10E+01 WR 21 L6442-02 10/29/2003 Zr-95 4.00E-01 3.00E+00 1.10E+01 WR 21 L6584-02 11/28/2003 Ba-140 6.70E+00 5.30E+00 1.80E+01 WR 21 L6584-02 11/28/2003 Co-58

-2.20E+00 1.60E+00 6.30E+00 WR 21 L6584-02 11/28/2003 Co-60 2.10E+00 1.50E+00 5.10E+00 WR 21 L6584-02 11/28/2003 Cs-134 1.00E+00 1.70E+00 6.10E+00 WR 21 L6584-02 11/28/2003 Cs-137

-1.00E-01 1.60E+00 5.90E+00 WR 21 L6584-02 11/28/2003 Fe-59

-9.00E-01 5.20E+00 2.00E+01 WR 21 L6584-02 11/28/2003 GR-B 1.40E+00 8.80E-01 2.90E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-34 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 21 L6584-02 11/28/2003 H-3 2.80E+02 4.30E+02 1.30E+03 WR 21 L6584-02 11/28/2003 I-131

-4.40E+00 8.20E+00 2.90E+01 WR 21 L6584-02 11/28/2003 Mn-54

-2.00E-01 1.70E+00 6.10E+00 WR 21 L6584-02 11/28/2003 Zn-65 8.10E+00 5.90E+00 2.00E+01 WR 21 L6584-02 11/28/2003 Zr-95

-4.80E+00 3.40E+00 1.30E+01 WR 21 L6732-02 12/29/2003 Ba-140

-3.50E+00 3.10E+00 1.40E+01 WR 21 L6732-02 12/29/2003 Co-58

-1.50E+00 1.50E+00 6.20E+00 WR 21 L6732-02 12/29/2003 Co-60 8.00E-01 1.80E+00 6.70E+00 WR 21 L6732-02 12/29/2003 Cs-134

-1.70E+00 1.30E+00 5.60E+00 WR 21 L6732-02 12/29/2003 Cs-137 3.00E-01 1.30E+00 4.90E+00 WR 21 L6732-02 12/29/2003 Fe-59

-1.00E+00 4.40E+00 1.80E+01 WR 21 L6732-02 12/29/2003 GR-B 2.30E+00 7.60E-01 2.30E+00 WR 21 L6732-02 12/29/2003 H-3 1.90E+02 3.10E+02 1.00E+03 WR 21 L6732-02 12/29/2003 I-131

-3.30E+00 3.60E+00 1.40E+01 WR 21 L6732-02 12/29/2003 Mn-54

-3.00E-01 1.50E+00 5.70E+00 WR 21 L6732-02 12/29/2003 Zn-65

-4.10E+00 3.50E+00 1.50E+01 WR 21 L6732-02 12/29/2003 Zr-95

-2.30E+00 3.00E+00 1.20E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-35 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 31 L4583-03 1/1/2003 Ba-140

-4.00E-01 2.00E+00 7.70E+00 WR 31 L4583-03 1/1/2003 Co-58

-1.80E+00 1.10E+00 4.70E+00 WR 31 L4583-03 1/1/2003 Co-60 1.10E+00 1.30E+00 4.50E+00 WR 31 L4583-03 1/1/2003 Cs-134

-8.00E-01 1.20E+00 4.70E+00 WR 31 L4583-03 1/1/2003 Cs-137

-1.20E+00 1.30E+00 4.90E+00 WR 31 L4583-03 1/1/2003 Fe-59 3.60E+00 2.20E+00 7.10E+00 WR 31 L4583-03 1/1/2003 GR-B 2.62E+00 9.00E-01 2.60E+00 WR 31 L4583-03 1/1/2003 H-3

-5.80E+02 4.10E+02 1.30E+03 WR 31 L4583-03 1/1/2003 I-131

-4.70E+00 2.10E+00 8.40E+00 WR 31 L4583-03 1/1/2003 Mn-54

-9.00E-01 1.20E+00 4.60E+00 WR 31 L4583-03 1/1/2003 Zn-65

-5.50E+00 2.60E+00 1.10E+01 WR 31 L4583-03 1/1/2003 Zr-95

-4.00E-01 1.90E+00 7.20E+00 WR 31 L4884-03 1/1/2003 H-3 4.00E+01 4.50E+02 1.30E+03 WR 31 L4795-03 1/29/2003 Ba-140

-1.10E+00 1.60E+00 6.60E+00 WR 31 L4795-03 1/29/2003 Co-58

-1.28E+00 9.50E-01 4.00E+00 WR 31 L4795-03 1/29/2003 Co-60

-3.10E+00 1.30E+00 5.50E+00 WR 31 L4795-03 1/29/2003 Cs-134

-2.10E+00 1.20E+00 5.10E+00 WR 31 L4795-03 1/29/2003 Cs-137

-9.00E-01 1.30E+00 5.00E+00 WR 31 L4795-03 1/29/2003 Fe-59 2.80E+00 2.20E+00 7.30E+00 WR 31 L4795-03 1/29/2003 GR-B 1.50E+00 9.20E-01 3.00E+00 WR 31 L4795-03 1/29/2003 H-3

-3.00E+01 4.20E+02 1.30E+03 WR 31 L4795-03 1/29/2003 I-131 5.00E-01 2.00E+00 7.20E+00 WR 31 L4795-03 1/29/2003 Mn-54 2.00E-01 1.10E+00 4.00E+00 WR 31 L4795-03 1/29/2003 Zn-65

-1.60E+00 2.20E+00 8.90E+00 WR 31 L4795-03 1/29/2003 Zr-95 6.00E-01 1.70E+00 6.10E+00 WR 31 L4971-03 2/25/2003 Ba-140

-2.50E+00 1.70E+00 7.60E+00 WR 31 L4971-03 2/25/2003 Co-58

-1.10E+00 1.10E+00 4.50E+00 WR 31 L4971-03 2/25/2003 Co-60

-2.00E+00 1.30E+00 5.50E+00 WR 31 L4971-03 2/25/2003 Cs-134 2.00E-01 1.30E+00 4.80E+00 WR 31 L4971-03 2/25/2003 Cs-137 2.50E+00 1.20E+00 3.80E+00 WR 31 L4971-03 2/25/2003 Fe-59

-4.00E-01 2.70E+00 1.00E+01 WR 31 L4971-03 2/25/2003 GR-B 2.00E+00 9.10E-01 2.80E+00 WR 31 L4971-03 2/25/2003 H-3

-3.60E+02 4.30E+02 1.30E+03 WR 31 L4971-03 2/25/2003 I-131

-1.10E+00 2.10E+00 7.70E+00 WR 31 L4971-03 2/25/2003 Mn-54 1.10E+00 1.00E+00 3.50E+00 WR 31 L4971-03 2/25/2003 Zn-65

-3.60E+00 2.60E+00 1.10E+01 WR 31 L4971-03 2/25/2003 Zr-95

-4.00E-01 1.90E+00 7.20E+00 WR 31 L5273-03 2/25/2003 H-3 3.40E+02 4.40E+02 1.30E+03 WR 31 L5212-03 4/2/2003 Ba-140

-6.00E-01 1.90E+00 8.20E+00 WR 31 L5212-03 4/2/2003 Co-58 2.20E+00 1.30E+00 4.30E+00 WR 31 L5212-03 4/2/2003 Co-60 1.60E+00 1.50E+00 5.10E+00 WR 31 L5212-03 4/2/2003 Cs-134 2.60E+00 1.40E+00 4.50E+00 WR 31 L5212-03 4/2/2003 Cs-137

-1.10E+00 1.40E+00 5.50E+00 WR 31 L5212-03 4/2/2003 Fe-59 1.80E+00 2.80E+00 1.00E+01 WR 31 L5212-03 4/2/2003 GR-B 9.80E-01 7.90E-01 2.70E+00 WR 31 L5212-03 4/2/2003 H-3

-4.50E+02 4.40E+02 1.30E+03 WR 31 L5212-03 4/2/2003 I-131

-3.40E+00 2.50E+00 9.80E+00 WR 31 L5212-03 4/2/2003 Mn-54 3.60E+00 1.40E+00 4.00E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-36 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 31 L5212-03 4/2/2003 Zn-65 5.00E+00 2.80E+00 8.80E+00 WR 31 L5212-03 4/2/2003 Zr-95 2.30E+00 2.60E+00 9.00E+00 WR 31 L5373-03 4/29/2003 Ba-140

-2.70E+00 2.90E+00 1.30E+01 WR 31 L5373-03 4/29/2003 Co-58

-9.00E-01 1.80E+00 7.60E+00 WR 31 L5373-03 4/29/2003 Co-60 1.10E+00 2.40E+00 9.30E+00 WR 31 L5373-03 4/29/2003 Cs-134

-2.10E+00 1.80E+00 8.50E+00 WR 31 L5373-03 4/29/2003 Cs-137

-1.60E+00 2.00E+00 8.30E+00 WR 31 L5373-03 4/29/2003 Fe-59

-2.30E+00 4.30E+00 1.80E+01 WR 31 L5373-03 4/29/2003 GR-B 1.60E+01 1.50E+00 2.60E+00 WR 31 L5373-03 4/29/2003 H-3

-5.60E+02 4.40E+02 1.30E+03 WR 31 L5373-03 4/29/2003 I-131

-1.60E+00 1.90E+00 7.90E+00 WR 31 L5373-03 4/29/2003 Mn-54 3.00E-01 1.50E+00 6.00E+00 WR 31 L5373-03 4/29/2003 Zn-65 6.20E+00 4.10E+00 1.30E+01 WR 31 L5373-03 4/29/2003 Zr-95

-5.50E+00 3.10E+00 1.50E+01 WR 31 L5530-03 5/27/2003 Ba-140

-4.00E-01 1.60E+00 6.50E+00 WR 31 L5530-03 5/27/2003 Co-58

-2.30E+00 1.10E+00 4.70E+00 WR 31 L5530-03 5/27/2003 Co-60 0.00E+00 1.10E+00 4.30E+00 WR 31 L5530-03 5/27/2003 Cs-134

-7.00E-01 1.10E+00 4.50E+00 WR 31 L5530-03 5/27/2003 Cs-137

-9.00E-01 1.30E+00 5.00E+00 WR 31 L5530-03 5/27/2003 Fe-59

-5.00E-01 1.90E+00 7.60E+00 WR 31 L5530-03 5/27/2003 GR-B 9.20E-01 8.10E-01 2.70E+00 WR 31 L5530-03 5/27/2003 H-3

-1.10E+02 4.40E+02 1.30E+03 WR 31 L5530-03 5/27/2003 I-131

-1.10E+00 1.90E+00 7.00E+00 WR 31 L5530-03 5/27/2003 Mn-54

-1.70E+00 1.20E+00 4.90E+00 WR 31 L5530-03 5/27/2003 Zn-65

-5.00E-01 2.30E+00 9.10E+00 WR 31 L5530-03 5/27/2003 Zr-95 1.40E+00 1.50E+00 5.40E+00 WR 31 L5724-03 6/30/2003 Ba-140

-4.40E+00 2.20E+00 1.00E+01 WR 31 L5724-03 6/30/2003 Co-58

-3.00E-01 1.30E+00 5.00E+00 WR 31 L5724-03 6/30/2003 Co-60 8.00E-01 1.60E+00 5.80E+00 WR 31 L5724-03 6/30/2003 Cs-134 1.10E+00 1.20E+00 4.30E+00 WR 31 L5724-03 6/30/2003 Cs-137

-3.70E+00 1.40E+00 6.20E+00 WR 31 L5724-03 6/30/2003 Fe-59 6.00E-01 2.60E+00 1.00E+01 WR 31 L5724-03 6/30/2003 GR-B 1.59E+00 8.50E-01 2.70E+00 WR 31 L5724-03 6/30/2003 H-3

-2.00E+02 3.90E+02 1.20E+03 WR 31 L5724-03 6/30/2003 I-131

-6.00E-01 2.30E+00 8.40E+00 WR 31 L5724-03 6/30/2003 Mn-54 1.80E+00 1.20E+00 3.80E+00 WR 31 L5724-03 6/30/2003 Zn-65 0.00E+00 2.80E+00 1.10E+01 WR 31 L5724-03 6/30/2003 Zr-95

-7.00E-01 2.40E+00 9.30E+00 WR 31 L5947-03 6/30/2003 H-3

-2.20E+02 3.90E+02 1.20E+03 WR 31 L5906-03 7/29/2003 Ba-140 3.80E+00 2.70E+00 8.70E+00 WR 31 L5906-03 7/29/2003 Co-58

-9.00E-01 1.60E+00 6.40E+00 WR 31 L5906-03 7/29/2003 Co-60 2.00E+00 1.30E+00 4.10E+00 WR 31 L5906-03 7/29/2003 Cs-134 2.00E-01 1.60E+00 6.00E+00 WR 31 L5906-03 7/29/2003 Cs-137 1.30E+00 1.70E+00 6.00E+00 WR 31 L5906-03 7/29/2003 Fe-59

-2.30E+00 3.20E+00 1.40E+01 WR 31 L5906-03 7/29/2003 GR-B 1.94E+00 8.80E-01 2.80E+00 WR 31 L5906-03 7/29/2003 H-3

-2.80E+02 4.20E+02 1.30E+03 WR 31 L5906-03 7/29/2003 I-131

-2.40E+00 5.00E+00 1.80E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-37 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 31 L5906-03 7/29/2003 Mn-54 8.00E-01 1.50E+00 5.40E+00 WR 31 L5906-03 7/29/2003 Zn-65

-5.20E+00 3.80E+00 1.60E+01 WR 31 L5906-03 7/29/2003 Zr-95

-1.90E+00 2.20E+00 9.50E+00 WR 31 L6026-03 8/25/2003 Ba-140 3.30E+00 2.60E+00 8.80E+00 WR 31 L6026-03 8/25/2003 Co-58

-2.20E+00 1.40E+00 6.40E+00 WR 31 L6026-03 8/25/2003 Co-60

-1.30E+00 1.60E+00 7.20E+00 WR 31 L6026-03 8/25/2003 Cs-134

-6.00E-01 1.80E+00 7.00E+00 WR 31 L6026-03 8/25/2003 Cs-137

-1.90E+00 1.40E+00 6.10E+00 WR 31 L6026-03 8/25/2003 Fe-59

-2.50E+00 5.10E+00 2.10E+01 WR 31 L6026-03 8/25/2003 GR-B 2.14E+00 9.20E-01 2.80E+00 WR 31 L6026-03 8/25/2003 H-3 2.30E+02 3.90E+02 1.20E+03 WR 31 L6026-03 8/25/2003 I-131

-8.00E-01 3.30E+00 1.20E+01 WR 31 L6026-03 8/25/2003 Mn-54 2.40E+00 1.50E+00 4.70E+00 WR 31 L6026-03 8/25/2003 Zn-65

-2.50E+00 3.40E+00 1.40E+01 WR 31 L6026-03 8/25/2003 Zr-95

-1.00E-01 2.50E+00 9.80E+00 WR 31 L6199-03 9/23/2003 Ba-140 0.00E+00 2.40E+00 1.00E+01 WR 31 L6199-03 9/23/2003 Co-58

-1.20E+00 1.50E+00 6.50E+00 WR 31 L6199-03 9/23/2003 Co-60 1.00E-01 2.00E+00 8.00E+00 WR 31 L6199-03 9/23/2003 Cs-134 1.60E+00 1.80E+00 6.30E+00 WR 31 L6199-03 9/23/2003 Cs-137

-7.00E-01 1.40E+00 5.80E+00 WR 31 L6199-03 9/23/2003 Fe-59 3.40E+00 4.10E+00 1.50E+01 WR 31 L6199-03 9/23/2003 GR-B 1.16E+00 8.40E-01 2.80E+00 WR 31 L6199-03 9/23/2003 H-3

-1.10E+02 4.00E+02 1.20E+03 WR 31 L6199-03 9/23/2003 I-131 1.00E-01 2.10E+00 7.80E+00 WR 31 L6199-03 9/23/2003 Mn-54

-3.40E+00 1.90E+00 8.30E+00 WR 31 L6199-03 9/23/2003 Zn-65 3.60E+00 3.40E+00 1.20E+01 WR 31 L6199-03 9/23/2003 Zr-95 1.60E+00 3.20E+00 1.20E+01 WR 31 L6511-03 9/23/2003 H-3 1.20E+02 4.30E+02 1.30E+03 WR 31 L6442-03 10/29/2003 Ba-140 2.30E+00 2.00E+00 6.90E+00 WR 31 L6442-03 10/29/2003 Co-58

-3.90E+00 1.40E+00 5.90E+00 WR 31 L6442-03 10/29/2003 Co-60 1.10E+00 1.30E+00 4.70E+00 WR 31 L6442-03 10/29/2003 Cs-134 5.00E-01 1.40E+00 5.00E+00 WR 31 L6442-03 10/29/2003 Cs-137

-8.00E-01 1.10E+00 4.50E+00 WR 31 L6442-03 10/29/2003 Fe-59 1.90E+00 2.60E+00 9.50E+00 WR 31 L6442-03 10/29/2003 GR-B 2.77E+00 9.20E-01 2.80E+00 WR 31 L6442-03 10/29/2003 H-3 3.00E+02 4.20E+02 1.30E+03 WR 31 L6442-03 10/29/2003 I-131

-1.20E+00 2.30E+00 8.60E+00 WR 31 L6442-03 10/29/2003 Mn-54 6.00E-01 1.00E+00 3.70E+00 WR 31 L6442-03 10/29/2003 Zn-65

-3.40E+00 2.70E+00 1.10E+01 WR 31 L6442-03 10/29/2003 Zr-95

-1.50E+00 1.90E+00 7.70E+00 WR 31 L6584-03 11/28/2003 Ba-140 0.00E+00 5.20E+00 1.90E+01 WR 31 L6584-03 11/28/2003 Co-58 3.00E-01 1.70E+00 6.10E+00 WR 31 L6584-03 11/28/2003 Co-60 4.00E-01 1.90E+00 7.00E+00 WR 31 L6584-03 11/28/2003 Cs-134 1.40E+00 1.70E+00 5.70E+00 WR 31 L6584-03 11/28/2003 Cs-137

-1.20E+00 1.40E+00 5.10E+00 WR 31 L6584-03 11/28/2003 Fe-59

-6.40E+00 5.60E+00 2.20E+01 WR 31 L6584-03 11/28/2003 GR-B

-3.70E-01 7.60E-01 2.80E+00 WR 31 L6584-03 11/28/2003 H-3 3.30E+02 4.10E+02 1.20E+03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-38 River Water SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WR 31 L6584-03 11/28/2003 I-131 5.20E+00 6.30E+00 2.10E+01 WR 31 L6584-03 11/28/2003 Mn-54

-1.10E+00 1.50E+00 5.80E+00 WR 31 L6584-03 11/28/2003 Zn-65

-3.30E+00 4.10E+00 1.50E+01 WR 31 L6584-03 11/28/2003 Zr-95

-3.30E+00 3.00E+00 1.10E+01 WR 31 L6732-03 12/29/2003 Ba-140 3.50E+00 3.50E+00 1.30E+01 WR 31 L6732-03 12/29/2003 Co-58

-4.00E-01 1.50E+00 6.30E+00 WR 31 L6732-03 12/29/2003 Co-60

-1.50E+00 2.00E+00 8.50E+00 WR 31 L6732-03 12/29/2003 Cs-134

-1.80E+00 1.80E+00 7.60E+00 WR 31 L6732-03 12/29/2003 Cs-137 2.80E+00 1.80E+00 5.90E+00 WR 31 L6732-03 12/29/2003 Fe-59 5.70E+00 3.70E+00 1.10E+01 WR 31 L6732-03 12/29/2003 GR-B 3.07E+00 9.40E-01 2.70E+00 WR 31 L6732-03 12/29/2003 H-3

-1.90E+02 3.00E+02 1.00E+03 WR 31 L6732-03 12/29/2003 I-131 3.10E+00 5.50E+00 2.00E+01 WR 31 L6732-03 12/29/2003 Mn-54 1.10E+00 1.60E+00 5.90E+00 WR 31 L6732-03 12/29/2003 Zn-65

-9.00E-01 3.10E+00 1.30E+01 WR 31 L6732-03 12/29/2003 Zr-95

-1.10E+00 2.90E+00 1.20E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-39 Storm Drains SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WW 51 L4583-06 1/1/2003 Ba-140

-5.00E-01 1.70E+00 6.70E+00 WW 51 L4583-06 1/1/2003 Co-58

-9.00E-01 1.20E+00 4.50E+00 WW 51 L4583-06 1/1/2003 Co-60

-2.00E-01 1.10E+00 4.10E+00 WW 51 L4583-06 1/1/2003 Cs-134

-1.90E+00 1.10E+00 4.60E+00 WW 51 L4583-06 1/1/2003 Cs-137 5.00E-01 1.10E+00 4.10E+00 WW 51 L4583-06 1/1/2003 Fe-59 7.00E-01 2.30E+00 8.30E+00 WW 51 L4583-06 1/1/2003 GR-B 8.90E+00 1.50E+00 3.80E+00 WW 51 L4583-06 1/1/2003 H-3

-8.90E+02 3.90E+02 1.20E+03 WW 51 L4583-06 1/1/2003 I-131 2.10E+00 2.30E+00 7.80E+00 WW 51 L4583-06 1/1/2003 Mn-54 2.00E-01 1.10E+00 3.80E+00 WW 51 L4583-06 1/1/2003 Zn-65

-1.50E+00 2.10E+00 8.50E+00 WW 51 L4583-06 1/1/2003 Zr-95

-2.20E+00 1.90E+00 7.70E+00 WW 51 L5212-06 4/2/2003 Ba-140

-1.37E+00 9.80E-01 5.10E+00 WW 51 L5212-06 4/2/2003 Co-58

-4.00E-01 1.00E+00 3.90E+00 WW 51 L5212-06 4/2/2003 Co-60 1.30E+00 1.20E+00 4.20E+00 WW 51 L5212-06 4/2/2003 Cs-134 2.00E-01 1.30E+00 4.70E+00 WW 51 L5212-06 4/2/2003 Cs-137 1.70E+00 1.20E+00 4.10E+00 WW 51 L5212-06 4/2/2003 Fe-59 9.00E-01 1.90E+00 7.20E+00 WW 51 L5212-06 4/2/2003 GR-B 1.71E+01 1.70E+00 3.30E+00 WW 51 L5212-06 4/2/2003 H-3

-8.00E+01 4.40E+02 1.30E+03 WW 51 L5212-06 4/2/2003 I-131

-1.30E+00 2.60E+00 9.30E+00 WW 51 L5212-06 4/2/2003 Mn-54 6.00E-01 1.10E+00 4.00E+00 WW 51 L5212-06 4/2/2003 Zn-65

-7.00E+00 3.20E+00 1.30E+01 WW 51 L5212-06 4/2/2003 Zr-95 2.70E+00 2.00E+00 6.80E+00 WW 51 L5373-07 4/29/2003 Ba-140

-2.70E+00 1.80E+00 8.10E+00 WW 51 L5373-07 4/29/2003 Co-58 1.50E+00 1.20E+00 3.90E+00 WW 51 L5373-07 4/29/2003 Co-60

-1.60E+00 1.70E+00 7.10E+00 WW 51 L5373-07 4/29/2003 Cs-134 2.10E+00 1.50E+00 5.20E+00 WW 51 L5373-07 4/29/2003 Cs-137 2.00E-01 1.30E+00 4.90E+00 WW 51 L5373-07 4/29/2003 Fe-59 6.00E-01 2.40E+00 9.10E+00 WW 51 L5373-07 4/29/2003 GR-B 1.94E+01 2.00E+00 4.50E+00 WW 51 L5373-07 4/29/2003 H-3 5.00E+02 4.70E+02 1.40E+03 WW 51 L5373-07 4/29/2003 I-131 5.00E-01 1.50E+00 5.20E+00 WW 51 L5373-07 4/29/2003 Mn-54 7.90E-01 9.90E-01 3.60E+00 WW 51 L5373-07 4/29/2003 Zn-65

-1.90E+00 2.90E+00 1.20E+01 WW 51 L5373-07 4/29/2003 Zr-95

-1.40E+00 2.40E+00 9.50E+00 WW 51 L5530-06 5/27/2003 Ba-140

-6.00E-01 2.20E+00 8.90E+00 WW 51 L5530-06 5/27/2003 Co-58 5.00E-01 1.20E+00 4.30E+00 WW 51 L5530-06 5/27/2003 Co-60 1.90E+00 1.70E+00 5.90E+00 WW 51 L5530-06 5/27/2003 Cs-134 4.00E-01 1.40E+00 5.20E+00 WW 51 L5530-06 5/27/2003 Cs-137

-2.00E-01 1.20E+00 4.70E+00 WW 51 L5530-06 5/27/2003 Fe-59

-3.10E+00 2.90E+00 1.20E+01 WW 51 L5530-06 5/27/2003 GR-B 8.90E+00 1.30E+00 3.10E+00 WW 51 L5530-06 5/27/2003 H-3 1.10E+02 4.60E+02 1.30E+03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-40 Storm Drains SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WW 51 L5530-06 5/27/2003 I-131

-1.70E+00 2.00E+00 7.80E+00 WW 51 L5530-06 5/27/2003 Mn-54 6.00E-01 1.30E+00 4.90E+00 WW 51 L5530-06 5/27/2003 Zn-65

-7.60E+00 3.20E+00 1.50E+01 WW 51 L5530-06 5/27/2003 Zr-95

-2.70E+00 2.20E+00 9.30E+00 WW 51 L5724-06 6/30/2003 Ba-140 1.00E+00 2.10E+00 8.10E+00 WW 51 L5724-06 6/30/2003 Co-58

-1.00E-01 1.30E+00 5.00E+00 WW 51 L5724-06 6/30/2003 Co-60 3.00E+00 1.50E+00 4.60E+00 WW 51 L5724-06 6/30/2003 Cs-134

-1.00E+00 1.20E+00 5.10E+00 WW 51 L5724-06 6/30/2003 Cs-137 1.60E+00 1.30E+00 4.40E+00 WW 51 L5724-06 6/30/2003 Fe-59

-7.00E-01 2.20E+00 9.40E+00 WW 51 L5724-06 6/30/2003 GR-B 1.23E+01 1.80E+00 4.00E+00 WW 51 L5724-06 6/30/2003 H-3

-2.10E+02 4.00E+02 1.20E+03 WW 51 L5724-06 6/30/2003 I-131

-3.00E-01 2.10E+00 7.70E+00 WW 51 L5724-06 6/30/2003 Mn-54

-6.00E-01 1.20E+00 4.80E+00 WW 51 L5724-06 6/30/2003 Zn-65

-5.50E+00 3.70E+00 1.50E+01 WW 51 L5724-06 6/30/2003 Zr-95

-2.90E+00 2.40E+00 1.00E+01 WW 51 L5906-07 7/29/2003 Ba-140

-2.00E+00 2.40E+00 9.40E+00 WW 51 L5906-07 7/29/2003 Co-58

-1.40E+00 1.10E+00 4.30E+00 WW 51 L5906-07 7/29/2003 Co-60 2.00E-01 1.10E+00 4.00E+00 WW 51 L5906-07 7/29/2003 Cs-134

-1.70E+00 1.00E+00 4.10E+00 WW 51 L5906-07 7/29/2003 Cs-137 1.04E+00 8.70E-01 3.00E+00 WW 51 L5906-07 7/29/2003 Fe-59

-4.60E+00 2.40E+00 9.70E+00 WW 51 L5906-07 7/29/2003 GR-B 1.51E+01 1.90E+00 4.20E+00 WW 51 L5906-07 7/29/2003 H-3 1.60E+02 4.10E+02 1.30E+03 WW 51 L5906-07 7/29/2003 I-131

-2.40E+00 2.50E+00 9.30E+00 WW 51 L5906-07 7/29/2003 Mn-54

-3.50E-01 9.10E-01 3.40E+00 WW 51 L5906-07 7/29/2003 Zn-65

-1.90E+00 1.90E+00 7.40E+00 WW 51 L5906-07 7/29/2003 Zr-95

-5.00E-01 1.80E+00 6.60E+00 WW 51 L6026-07 8/25/2003 Ba-140 7.00E-01 2.70E+00 1.10E+01 WW 51 L6026-07 8/25/2003 Co-58

-1.70E+00 1.50E+00 6.50E+00 WW 51 L6026-07 8/25/2003 Co-60 9.00E-01 1.30E+00 4.80E+00 WW 51 L6026-07 8/25/2003 Cs-134

-1.10E+00 1.50E+00 6.40E+00 WW 51 L6026-07 8/25/2003 Cs-137

-1.20E+00 1.70E+00 6.80E+00 WW 51 L6026-07 8/25/2003 Fe-59

-5.00E-01 3.60E+00 1.50E+01 WW 51 L6026-07 8/25/2003 GR-B 1.84E+01 1.90E+00 4.20E+00 WW 51 L6026-07 8/25/2003 H-3

-2.30E+02 4.00E+02 1.20E+03 WW 51 L6026-07 8/25/2003 I-131 3.00E+00 3.10E+00 1.10E+01 WW 51 L6026-07 8/25/2003 Mn-54

-3.00E-01 1.40E+00 5.70E+00 WW 51 L6026-07 8/25/2003 Zn-65

-9.00E-01 3.60E+00 1.40E+01 WW 51 L6026-07 8/25/2003 Zr-95 1.80E+00 2.60E+00 9.50E+00 WW 51 L6199-06 9/23/2003 Ba-140

-7.00E-01 1.90E+00 7.50E+00 WW 51 L6199-06 9/23/2003 Co-58 2.60E+00 1.30E+00 4.20E+00 WW 51 L6199-06 9/23/2003 Co-60 5.00E-01 1.30E+00 4.80E+00 WW 51 L6199-06 9/23/2003 Cs-134

-2.00E+00 1.30E+00 5.30E+00 WW 51 L6199-06 9/23/2003 Cs-137

-1.50E+00 1.20E+00 4.70E+00 WW 51 L6199-06 9/23/2003 Fe-59 4.70E+00 3.50E+00 1.20E+01 WW 51 L6199-06 9/23/2003 GR-B 1.94E+00 9.00E-01 2.80E+00 WW 51 L6199-06 9/23/2003 H-3 1.80E+02 4.10E+02 1.20E+03

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-41 Storm Drains SAMPLE END CONC STD.DEV.

MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WW 51 L6199-06 9/23/2003 I-131 7.00E-01 1.70E+00 6.20E+00 WW 51 L6199-06 9/23/2003 Mn-54 2.00E-01 1.40E+00 5.10E+00 WW 51 L6199-06 9/23/2003 Zn-65

-3.30E+00 2.70E+00 1.10E+01 WW 51 L6199-06 9/23/2003 Zr-95 0.00E+00 1.80E+00 6.70E+00 WW 51 L6442-07 10/29/2003 Ba-140

-2.70E+00 2.90E+00 1.60E+01 WW 51 L6442-07 10/29/2003 Co-58 1.80E+00 2.20E+00 8.00E+00 WW 51 L6442-07 10/29/2003 Co-60 1.30E+00 1.90E+00 7.30E+00 WW 51 L6442-07 10/29/2003 Cs-134 2.00E-01 1.80E+00 7.50E+00 WW 51 L6442-07 10/29/2003 Cs-137 1.50E+00 1.50E+00 5.20E+00 WW 51 L6442-07 10/29/2003 Fe-59 0.00E+00 5.70E+00 2.40E+01 WW 51 L6442-07 10/29/2003 GR-B 2.54E+00 9.40E-01 2.90E+00 WW 51 L6442-07 10/29/2003 H-3

-6.00E+01 4.10E+02 1.20E+03 WW 51 L6442-07 10/29/2003 I-131 2.80E+00 4.30E+00 1.60E+01 WW 51 L6442-07 10/29/2003 Mn-54

-2.70E+00 2.00E+00 9.00E+00 WW 51 L6442-07 10/29/2003 Zn-65

-6.50E+00 3.90E+00 1.90E+01 WW 51 L6442-07 10/29/2003 Zr-95 4.10E+00 3.60E+00 1.30E+01 WW 51 L6584-06 11/28/2003 Ba-140

-4.50E+00 3.80E+00 1.50E+01 WW 51 L6584-06 11/28/2003 Co-58

-2.20E+00 1.40E+00 5.50E+00 WW 51 L6584-06 11/28/2003 Co-60

-1.10E+00 1.50E+00 5.80E+00 WW 51 L6584-06 11/28/2003 Cs-134 2.10E+00 1.40E+00 4.50E+00 WW 51 L6584-06 11/28/2003 Cs-137

-7.00E-01 1.20E+00 4.30E+00 WW 51 L6584-06 11/28/2003 Fe-59

-6.00E+00 4.00E+00 1.60E+01 WW 51 L6584-06 11/28/2003 GR-B 5.50E+00 1.20E+00 3.10E+00 WW 51 L6584-06 11/28/2003 H-3

-4.10E+02 3.10E+02 1.00E+03 WW 51 L6584-06 11/28/2003 I-131 6.20E+00 6.90E+00 2.30E+01 WW 51 L6584-06 11/28/2003 Mn-54 2.40E+00 1.40E+00 4.50E+00 WW 51 L6584-06 11/28/2003 Zn-65

-6.00E+00 3.30E+00 1.30E+01 WW 51 L6584-06 11/28/2003 Zr-95 0.00E+00 2.70E+00 9.60E+00 WW 51 L6732-06 12/29/2003 Ba-140

-3.40E+00 3.40E+00 1.80E+01 WW 51 L6732-06 12/29/2003 Co-58

-7.00E-01 1.70E+00 7.60E+00 WW 51 L6732-06 12/29/2003 Co-60

-1.90E+00 2.00E+00 9.90E+00 WW 51 L6732-06 12/29/2003 Cs-134

-3.00E+00 1.70E+00 8.70E+00 WW 51 L6732-06 12/29/2003 Cs-137 1.50E+00 2.20E+00 7.90E+00 WW 51 L6732-06 12/29/2003 Fe-59 8.30E+00 5.40E+00 1.70E+01 WW 51 L6732-06 12/29/2003 GR-B 4.40E+00 8.80E-01 2.40E+00 WW 51 L6732-06 12/29/2003 H-3

-1.60E+02 3.10E+02 1.00E+03 WW 51 L6732-06 12/29/2003 I-131 5.40E+00 6.30E+00 2.20E+01 WW 51 L6732-06 12/29/2003 Mn-54 4.00E-01 1.80E+00 7.00E+00 WW 51 L6732-06 12/29/2003 Zn-65

-5.40E+00 4.70E+00 2.10E+01 WW 51 L6732-06 12/29/2003 Zr-95 2.20E+00 3.90E+00 1.50E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-42 Storm Drains SAMPLE END CONC STD.DEV MDC TYPE STATIO N

LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WW 52 L4583-07 1/1/2003 Ba-140 4.00E-01 2.00E+00 7.50E+00 WW 52 L4583-07 1/1/2003 Co-58

-9.00E-01 1.10E+00 4.30E+00 WW 52 L4583-07 1/1/2003 Co-60

-9.00E-01 1.30E+00 5.00E+00 WW 52 L4583-07 1/1/2003 Cs-134

-4.00E-01 1.30E+00 4.80E+00 WW 52 L4583-07 1/1/2003 Cs-137 3.00E-01 1.30E+00 4.60E+00 WW 52 L4583-07 1/1/2003 Fe-59

-2.40E+00 2.30E+00 9.20E+00 WW 52 L4583-07 1/1/2003 GR-B 6.80E+00 1.30E+00 3.30E+00 WW 52 L4583-07 1/1/2003 H-3

-3.00E+01 4.10E+02 1.20E+03 WW 52 L4583-07 1/1/2003 I-131 2.30E+00 2.30E+00 7.90E+00 WW 52 L4583-07 1/1/2003 Mn-54 8.00E-01 1.20E+00 4.10E+00 WW 52 L4583-07 1/1/2003 Zn-65 5.90E+00 5.20E+00 1.80E+01 WW 52 L4583-07 1/1/2003 Zr-95 8.00E-01 1.80E+00 6.50E+00 WW 52 L4795-07 1/29/2003 Ba-140 3.10E+00 2.80E+00 9.70E+00 WW 52 L4795-07 1/29/2003 Co-58 1.10E+00 1.20E+00 4.20E+00 WW 52 L4795-07 1/29/2003 Co-60 2.70E+00 1.50E+00 4.90E+00 WW 52 L4795-07 1/29/2003 Cs-134 6.00E-01 1.50E+00 5.60E+00 WW 52 L4795-07 1/29/2003 Cs-137

-2.90E+00 1.50E+00 6.20E+00 WW 52 L4795-07 1/29/2003 Fe-59 6.00E-01 3.20E+00 1.20E+01 WW 52 L4795-07 1/29/2003 GR-B 1.49E+01 1.80E+00 3.70E+00 WW 52 L4795-07 1/29/2003 H-3

-3.70E+02 4.20E+02 1.30E+03 WW 52 L4795-07 1/29/2003 I-131 5.30E+00 3.00E+00 9.80E+00 WW 52 L4795-07 1/29/2003 Mn-54

-3.50E+00 1.40E+00 6.10E+00 WW 52 L4795-07 1/29/2003 Zn-65

-8.80E+00 4.00E+00 1.70E+01 WW 52 L4795-07 1/29/2003 Zr-95 2.80E+00 2.10E+00 7.20E+00 WW 52 L4971-07 2/25/2003 Ba-140

-1.60E+00 1.40E+00 5.50E+00 WW 52 L4971-07 2/25/2003 Co-58 0.00E+00 8.50E-01 3.10E+00 WW 52 L4971-07 2/25/2003 Co-60 2.39E+00 8.80E-01 2.60E+00 WW 52 L4971-07 2/25/2003 Cs-134

-9.10E-01 8.60E-01 3.30E+00 WW 52 L4971-07 2/25/2003 Cs-137

-7.10E-01 8.30E-01 3.10E+00 WW 52 L4971-07 2/25/2003 Fe-59

-2.50E+00 1.80E+00 7.00E+00 WW 52 L4971-07 2/25/2003 GR-B 1.63E+01 2.30E+00 5.30E+00 WW 52 L4971-07 2/25/2003 H-3

-1.80E+02 4.20E+02 1.30E+03 WW 52 L4971-07 2/25/2003 I-131

-7.00E-01 1.80E+00 6.30E+00 WW 52 L4971-07 2/25/2003 Mn-54

-6.10E-01 7.60E-01 2.90E+00 WW 52 L4971-07 2/25/2003 Zn-65 7.20E+00 3.30E+00 1.10E+01 WW 52 L4971-07 2/25/2003 Zr-95 6.00E-01 1.50E+00 5.20E+00 WW 52 L5212-07 4/2/2003 Ba-140 1.00E+00 1.50E+00 5.60E+00 WW 52 L5212-07 4/2/2003 Co-58

-7.80E-01 9.60E-01 3.90E+00 WW 52 L5212-07 4/2/2003 Co-60

-8.00E-01 1.20E+00 5.00E+00 WW 52 L5212-07 4/2/2003 Cs-134 8.00E-01 1.10E+00 3.80E+00 WW 52 L5212-07 4/2/2003 Cs-137

-4.00E-01 1.20E+00 4.40E+00 WW 52 L5212-07 4/2/2003 Fe-59

-3.00E-01 2.50E+00 9.40E+00 WW 52 L5212-07 4/2/2003 GR-B 1.27E+01 2.40E+00 6.20E+00 WW 52 L5212-07 4/2/2003 H-3

-4.40E+02 4.50E+02 1.30E+03 WW 52 L5212-07 4/2/2003 I-131

-1.20E+00 2.00E+00 7.60E+00 WW 52 L5212-07 4/2/2003 Mn-54 1.70E+00 1.10E+00 3.80E+00 WW 52 L5212-07 4/2/2003 Zn-65

-6.00E+00 2.50E+00 1.10E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-43 Storm Drains SAMPLE END CONC STD.DEV MDC TYPE STATIO N

LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WW 52 L5212-07 4/2/2003 Zr-95 3.40E+00 2.10E+00 6.80E+00 WW 52 L5373-08 4/29/2003 Ba-140

-9.00E-01 2.00E+00 8.10E+00 WW 52 L5373-08 4/29/2003 Co-58 1.50E+00 1.40E+00 4.90E+00 WW 52 L5373-08 4/29/2003 Co-60

-4.00E-01 1.60E+00 6.50E+00 WW 52 L5373-08 4/29/2003 Cs-134

-5.00E-01 1.50E+00 5.70E+00 WW 52 L5373-08 4/29/2003 Cs-137 1.30E+00 1.30E+00 4.40E+00 WW 52 L5373-08 4/29/2003 Fe-59 6.00E-01 2.70E+00 1.00E+01 WW 52 L5373-08 4/29/2003 GR-B 9.60E+00 1.60E+00 3.70E+00 WW 52 L5373-08 4/29/2003 H-3

-6.30E+02 4.50E+02 1.40E+03 WW 52 L5373-08 4/29/2003 I-131

-8.00E-01 1.50E+00 5.60E+00 WW 52 L5373-08 4/29/2003 Mn-54 2.00E-01 1.20E+00 4.70E+00 WW 52 L5373-08 4/29/2003 Zn-65

-4.30E+00 3.10E+00 1.30E+01 WW 52 L5373-08 4/29/2003 Zr-95

-1.40E+00 2.40E+00 9.50E+00 WW 52 L5530-07 5/27/2003 Ba-140

-2.20E+00 1.90E+00 8.80E+00 WW 52 L5530-07 5/27/2003 Co-58

-3.00E-01 1.20E+00 4.80E+00 WW 52 L5530-07 5/27/2003 Co-60

-2.20E+00 1.30E+00 6.20E+00 WW 52 L5530-07 5/27/2003 Cs-134

-2.00E-01 1.50E+00 5.90E+00 WW 52 L5530-07 5/27/2003 Cs-137

-1.20E+00 1.50E+00 5.80E+00 WW 52 L5530-07 5/27/2003 Fe-59 3.60E+00 3.30E+00 1.10E+01 WW 52 L5530-07 5/27/2003 GR-B 5.90E+00 1.30E+00 3.50E+00 WW 52 L5530-07 5/27/2003 H-3 3.00E+02 4.60E+02 1.30E+03 WW 52 L5530-07 5/27/2003 I-131 2.50E+00 2.30E+00 7.80E+00 WW 52 L5530-07 5/27/2003 Mn-54

-4.00E-01 1.00E+00 4.20E+00 WW 52 L5530-07 5/27/2003 Zn-65 2.50E+00 2.70E+00 9.40E+00 WW 52 L5530-07 5/27/2003 Zr-95

-2.00E+00 2.40E+00 9.50E+00 WW 52 L5724-07 6/30/2003 Ba-140 0.00E+00 1.30E+00 4.90E+00 WW 52 L5724-07 6/30/2003 Co-58 1.08E+00 8.10E-01 2.70E+00 WW 52 L5724-07 6/30/2003 Co-60

-1.60E+00 1.00E+00 4.30E+00 WW 52 L5724-07 6/30/2003 Cs-134

-9.00E-01 1.00E+00 4.00E+00 WW 52 L5724-07 6/30/2003 Cs-137 2.29E+00 9.90E-01 3.10E+00 WW 52 L5724-07 6/30/2003 Fe-59

-1.00E+00 1.90E+00 7.20E+00 WW 52 L5724-07 6/30/2003 GR-B 1.20E+01 1.70E+00 3.90E+00 WW 52 L5724-07 6/30/2003 H-3

-2.60E+02 3.90E+02 1.20E+03 WW 52 L5724-07 6/30/2003 I-131

-1.20E+00 1.70E+00 6.20E+00 WW 52 L5724-07 6/30/2003 Mn-54 0.00E+00 7.80E-01 2.90E+00 WW 52 L5724-07 6/30/2003 Zn-65

-1.10E+00 2.10E+00 8.00E+00 WW 52 L5724-07 6/30/2003 Zr-95 0.00E+00 1.30E+00 4.90E+00 WW 52 L5906-08 7/29/2003 Ba-140 1.60E+00 2.00E+00 7.10E+00 WW 52 L5906-08 7/29/2003 Co-58

-2.00E-01 8.90E-01 3.30E+00 WW 52 L5906-08 7/29/2003 Co-60

-4.80E-01 9.60E-01 3.80E+00 WW 52 L5906-08 7/29/2003 Cs-134

-1.80E+00 1.00E+00 4.10E+00 WW 52 L5906-08 7/29/2003 Cs-137 6.70E-01 8.40E-01 2.90E+00 WW 52 L5906-08 7/29/2003 Fe-59 2.30E+00 2.20E+00 7.50E+00 WW 52 L5906-08 7/29/2003 GR-B 9.10E+00 1.50E+00 3.60E+00 WW 52 L5906-08 7/29/2003 H-3

-3.90E+02 4.00E+02 1.30E+03 WW 52 L5906-08 7/29/2003 I-131 3.30E+00 2.90E+00 9.70E+00

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-44 WW 52 L5906-08 7/29/2003 Mn-54

-1.11E+00 9.00E-01 3.50E+00 Storm Drains SAMPLE END CONC STD.DEV MDC TYPE STATIO N

LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WW 52 L5906-08 7/29/2003 Zn-65 5.40E+00 3.80E+00 1.30E+01 WW 52 L5906-08 7/29/2003 Zr-95 2.40E+00 1.70E+00 5.70E+00 WW 52 L6026-08 8/25/2003 Ba-140 4.20E+00 2.30E+00 7.00E+00 WW 52 L6026-08 8/25/2003 Co-58

-7.00E-01 1.40E+00 5.80E+00 WW 52 L6026-08 8/25/2003 Co-60 0.00E+00 1.60E+00 6.40E+00 WW 52 L6026-08 8/25/2003 Cs-134

-7.00E-01 1.60E+00 6.40E+00 WW 52 L6026-08 8/25/2003 Cs-137

-9.00E-01 1.50E+00 6.00E+00 WW 52 L6026-08 8/25/2003 Fe-59

-4.50E+00 4.50E+00 1.90E+01 WW 52 L6026-08 8/25/2003 GR-B 1.10E+01 1.60E+00 3.80E+00 WW 52 L6026-08 8/25/2003 H-3

-4.00E+01 3.90E+02 1.20E+03 WW 52 L6026-08 8/25/2003 I-131 1.40E+00 2.70E+00 9.80E+00 WW 52 L6026-08 8/25/2003 Mn-54

-6.00E-01 1.40E+00 5.70E+00 WW 52 L6026-08 8/25/2003 Zn-65

-1.00E+00 3.80E+00 1.50E+01 WW 52 L6026-08 8/25/2003 Zr-95 5.20E+00 2.60E+00 8.10E+00 WW 52 L6199-07 9/23/2003 Ba-140

-8.00E-01 2.50E+00 1.10E+01 WW 52 L6199-07 9/23/2003 Co-58

-8.00E-01 1.50E+00 6.30E+00 WW 52 L6199-07 9/23/2003 Co-60 2.00E-01 2.00E+00 8.10E+00 WW 52 L6199-07 9/23/2003 Cs-134 1.00E-01 1.60E+00 6.30E+00 WW 52 L6199-07 9/23/2003 Cs-137

-1.10E+00 1.60E+00 6.80E+00 WW 52 L6199-07 9/23/2003 Fe-59 2.80E+00 5.30E+00 2.00E+01 WW 52 L6199-07 9/23/2003 GR-B 4.80E+00 1.10E+00 2.80E+00 WW 52 L6199-07 9/23/2003 H-3 0.00E+00 4.00E+02 1.20E+03 WW 52 L6199-07 9/23/2003 I-131 3.60E+00 2.40E+00 7.90E+00 WW 52 L6199-07 9/23/2003 Mn-54 9.00E-01 1.50E+00 5.70E+00 WW 52 L6199-07 9/23/2003 Zn-65 2.00E+00 3.10E+00 1.20E+01 WW 52 L6199-07 9/23/2003 Zr-95

-9.00E-01 3.00E+00 1.20E+01 WW 52 L6442-08 10/29/2003 Ba-140 1.90E+00 3.80E+00 1.50E+01 WW 52 L6442-08 10/29/2003 Co-58 1.00E+00 2.30E+00 8.80E+00 WW 52 L6442-08 10/29/2003 Co-60 5.00E-01 1.70E+00 7.00E+00 WW 52 L6442-08 10/29/2003 Cs-134

-5.90E+00 2.20E+00 1.10E+01 WW 52 L6442-08 10/29/2003 Cs-137 9.00E-01 1.80E+00 6.90E+00 WW 52 L6442-08 10/29/2003 Fe-59 5.80E+00 4.30E+00 1.40E+01 WW 52 L6442-08 10/29/2003 GR-B 2.64E+00 9.80E-01 3.00E+00 WW 52 L6442-08 10/29/2003 H-3

-2.00E+02 4.10E+02 1.30E+03 WW 52 L6442-08 10/29/2003 I-131

-9.00E-01 4.60E+00 1.80E+01 WW 52 L6442-08 10/29/2003 Mn-54

-4.00E-01 1.70E+00 7.00E+00 WW 52 L6442-08 10/29/2003 Zn-65

-6.20E+00 5.70E+00 2.40E+01 WW 52 L6442-08 10/29/2003 Zr-95 2.00E+00 3.50E+00 1.30E+01 WW 52 L6584-07 11/28/2003 Ba-140

-7.20E+00 5.70E+00 2.30E+01 WW 52 L6584-07 11/28/2003 Co-58

-1.70E+00 1.80E+00 6.90E+00 WW 52 L6584-07 11/28/2003 Co-60

-3.40E+00 2.10E+00 8.40E+00 WW 52 L6584-07 11/28/2003 Cs-134

-1.00E-01 2.10E+00 7.60E+00 WW 52 L6584-07 11/28/2003 Cs-137 4.00E-01 1.70E+00 6.20E+00 WW 52 L6584-07 11/28/2003 Fe-59

-5.60E+00 5.60E+00 2.30E+01

Yankee Rowe Station Annual Radiological Environmental Operating Report 2003

  • Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)

C-45 WW 52 L6584-07 11/28/2003 GR-B 8.40E+00 1.40E+00 3.50E+00 WW 52 L6584-07 11/28/2003 H-3

-1.80E+02 4.10E+02 1.30E+03 WW 52 L6584-07 11/28/2003 I-131 7.00E-01 7.30E+00 2.60E+01 Storm Drains SAMPLE END CONC STD.DEV MDC TYPE STATIO N

LSN DATE NUCLIDE (pCi/kg)

(pCi/kg)

(pCi/kg)

WW 52 L6584-07 11/28/2003 Mn-54

-8.00E-01 1.80E+00 6.60E+00 WW 52 L6584-07 11/28/2003 Zn-65

-3.30E+00 3.90E+00 1.50E+01 WW 52 L6584-07 11/28/2003 Zr-95

-6.00E-01 3.40E+00 1.20E+01 WW 52 L6732-07 12/29/2003 Ba-140 0.00E+00 5.10E+00 2.10E+01 WW 52 L6732-07 12/29/2003 Co-58

-1.10E+00 2.40E+00 9.50E+00 WW 52 L6732-07 12/29/2003 Co-60

-9.00E-01 1.60E+00 7.50E+00 WW 52 L6732-07 12/29/2003 Cs-134

-4.00E-01 1.90E+00 7.70E+00 WW 52 L6732-07 12/29/2003 Cs-137 1.40E+00 2.40E+00 8.60E+00 WW 52 L6732-07 12/29/2003 Fe-59

-7.30E+00 7.10E+00 3.10E+01 WW 52 L6732-07 12/29/2003 GR-B 4.16E+00 8.90E-01 2.50E+00 WW 52 L6732-07 12/29/2003 H-3 4.00E+01 3.10E+02 1.00E+03 WW 52 L6732-07 12/29/2003 I-131

-4.60E+00 5.80E+00 2.30E+01 WW 52 L6732-07 12/29/2003 Mn-54 1.30E+00 1.70E+00 6.30E+00 WW 52 L6732-07 12/29/2003 Zn-65

-1.03E+01 5.70E+00 2.50E+01 WW 52 L6732-07 12/29/2003 Zr-95 2.90E+00 3.10E+00 1.10E+01