IR 05000458-04-010, on 03/22/2003 - 03/25/2004; River Bend Station; Security Review of Access Control
ML041050432
Person / Time
Site: River Bend 
Issue date: 04/12/2004
From: Shannon M
Plant Support Branch Region IV
To: Hinnenkamp P
Entergy Operations
References
IR-04-010
Download: ML041050432 (8)


Text

April 12, 2004

SUBJECT:

RIVER BEND - NRC PHYSICAL SECURITY LIMITED BASELINE INSPECTION REPORT 05000458/2004010

Dear Mr. Hinnenkamp:

On March 25, 2004, the NRC completed the onsite portion of an inspection at your River Bend Station. The enclosed report documents the inspection findings, which were discussed with yourself and other members of your staff.

This inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

Within these areas, the inspection consisted of selected examination of procedures and representative records, observations of activities, and interviews with personnel.

The material enclosed herewith contains Safeguards Information as defined by 10 CFR 73.21 and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy Act of 1954, as amended. Therefore, the material will not be placed in the Public Document Room.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, without enclosure, will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Entergy Operations, Inc. -2-ENCLOSURE(S) CONTAIN(S) UPON SEPARATION THIS PAGE IS DECONTROLLED Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

//RA//

Michael P. Shannon, Chief Plant Support Branch Division of Reactor Safety Docket: 50-458 Licenses: NPF-47

Enclosure:

NRC Inspection Report 05000458/2004010 w/Attachment:

Supplemental Information

REGION IV==

Docket No.:

50-458 License No.:

NPF-47 Report No.:

05000458/2004010 Licensee:

Entergy Operations, Inc.

Facility:

River Bend Station Location:

5485 U.S. Highway 61 St. Francisville, Louisiana Dates:

March 22 - 25, 2004 Inspectors:

Gregory A. Pick, Senior Physical Security Inspector Dennis W. Schaefer, Consultant Approved by:

Michael P. Shannon, Chief, Plant Support Branch Division of Reactor Safety ENCLOSURE(S) CONTAIN(S) UPON SEPARATION THIS PAGE IS DECONTROLLED