Letter Sequence Meeting |
|---|
|
|
MONTHYEARML0308504672003-03-20020 March 2003 TS Proposed Change No.257, Implementation of Arts/Mella Project stage: Request BVY 03-027, Cycle 22 10CFR50.59 Report2003-03-20020 March 2003 Cycle 22 10CFR50.59 Report Project stage: Request ML0309206482003-04-15015 April 2003 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML0312001442003-04-25025 April 2003 Instrumentation Technical Specifications Proposed Change No. 259 Project stage: Request ML0312101232003-05-0707 May 2003 Summary of April 29, 2003, Category 1 Meeting with ENVY, to Discuss Arts/Mella Application Project stage: Meeting ML0313900392003-05-21021 May 2003 Request for Additional Information, Arts/Mellla Project stage: RAI ML0317005452003-06-11011 June 2003 Instrumentation TS Proposed Change No 259 Project stage: Request ML0322702812003-08-25025 August 2003 Request for Withholding Information from Public Disclosure, GE Proprietary Information, GE-VYNPS-AEP-214, Panacea and Iscor Files Project stage: Withholding Request Acceptance ML0323403792003-08-31031 August 2003 Technical Assessment of Quad Cities Unit 2, Steam Dryer Failure - Determination of Root Cause & Extent of Condition Project stage: Request ML0325800892003-09-10010 September 2003 Technical Specification Proposed Change No. 263 Extended Power Uprate Project stage: Request ML0328104472003-10-0101 October 2003 Technical Specification Proposed Change No. 263, Supplemental No. 1 Regarding Extended Power Uprate, Technical Review Guidance Project stage: Request ML0330403972003-10-30030 October 2003 Meeting Handouts for Meeting with Entergy Re Issues for Alternate Source Term, Power Uprate & Acts/Mellla Application Project stage: Meeting ML0331000472003-10-30030 October 2003 Sign-in Sheet for 10/30/2003 Meeting with ENVY and ENO Re to Discuss Arts/Mellla, Alternate Source Term, and Extended Power Uprate Aplications Project stage: Meeting ML0331000232003-11-19019 November 2003 Meeting with Entergy Nuclear Vermont Yankee, LLC and Entergy Nuclear Operations, Inc Regarding Arts/Mellla, Alternate Source Term, and Extended Power Uprate Applications Project stage: Meeting ML0330902512003-12-0101 December 2003 Alternative Source Term Request for Additional Information Project stage: RAI BVY 03-115, Technical Specification Proposed Change No. 257 Implementation of Arts/Smella at VYNPS Supplemental Information and Proposed Allowable Value, Attachment 2, Calculation VYC-0693A2003-12-11011 December 2003 Technical Specification Proposed Change No. 257 Implementation of Arts/Smella at VYNPS Supplemental Information and Proposed Allowable Value, Attachment 2, Calculation VYC-0693A Project stage: Request ML0331800882003-12-15015 December 2003 Extended Power Uprate Acceptance Review Project stage: Acceptance Review ML0331601872003-12-16016 December 2003 Withholding from Public Disclosure, NEDC-33090P, Revision 0, Project stage: Other ML0430204942003-12-24024 December 2003 NRR Work Request to IEPB-A Project stage: Other ML0336401382003-12-30030 December 2003 Draft Request for Additional Information Project stage: Draft RAI ML0400606952004-01-0606 January 2004 Draft Request for Additional Information Project stage: Draft RAI ML0400805732004-01-0707 January 2004 NPSH for BWR Extended Power Upgrades (EPU) Project stage: Other ML0400904112004-01-0909 January 2004 NPSH for BWR Extended Power Upgrades (EPU) Project stage: Other ML0403000882004-01-30030 January 2004 Draft Request for Additional Information Project stage: Draft RAI BVY 04-009, Technical Specification Proposed Change No. 263, Supplement No. 4 Regarding Extended Power Uprate, NRC Acceptance Review2004-01-31031 January 2004 Technical Specification Proposed Change No. 263, Supplement No. 4 Regarding Extended Power Uprate, NRC Acceptance Review Project stage: Supplement ML0402002262004-02-0202 February 2004 Request for Withholding Information from Public Disclosure, Calculation Psat 3019CF.QA.04, Post LOCA (loss-of-coolant Accident) Suppression Pool Ph for Vermont Yankee Project stage: Withholding Request Acceptance BVY 04-015, Technical Specification Proposed Change No. 257, Supplement No. 6 Regarding Implementation of Arts/Mella Calibration of APRM High Flux Flow Biastrip Function2004-02-10010 February 2004 Technical Specification Proposed Change No. 257, Supplement No. 6 Regarding Implementation of Arts/Mella Calibration of APRM High Flux Flow Biastrip Function Project stage: Request ML0404800772004-02-17017 February 2004 Draft Request for Additional Information Project stage: Draft RAI ML0404902362004-02-18018 February 2004 Draft Request for Additional Information Project stage: Draft RAI ML0404001612004-02-19019 February 2004 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML0405003022004-02-20020 February 2004 Extended Power Uprate Acceptance Review Project stage: Acceptance Review ML0406306032004-02-27027 February 2004 G20040138/LTR-04-0107 - Sen. James Jeffords & Patrick Leahy Ltr Proposed Power Uprate at Vermont Yankee Project stage: Request BVY 04-026, Technical Specification Proposed Change No. 257, Supplement 7, Implementation of Arts/Mella at Vermont Yankee, Revised Anticipated Transient Without Scram Evaluation2004-03-11011 March 2004 Technical Specification Proposed Change No. 257, Supplement 7, Implementation of Arts/Mella at Vermont Yankee, Revised Anticipated Transient Without Scram Evaluation Project stage: Request ML0408500762004-03-15015 March 2004 G20040206/LTR-04-0168 - Ltr. Rep. Michael Dworkin Independent Safety Asessment of Vermont Yankee Project stage: Request ML0404100222004-03-19019 March 2004 Withholding from Public Disclosure, Responses to Request for Additional Information (Attachment 1 to Letter Bvy 04-008) Project stage: RAI ML0411203582004-03-31031 March 2004 Transcription Meeting Summary, 03/31/2004 Category 3 Meeting with Public to Discuss Proposed Power Uprate, Pages 1-124 Project stage: Meeting ML0411007042004-03-31031 March 2004 Enclosure 1, March 31, 2004, Vermont Yankee Annual Assessment Meeting Power Up-Rate Public Meeting Attendance List Project stage: Meeting ML0411202522004-04-14014 April 2004 Technical Specification Pages for Vermont Yankee Nuclear Power Station, License Amendment, Issuance of Amendment Implementation of Arts/Mellla Project stage: Approval ML0409203522004-04-14014 April 2004 License Amendment, Revise Technical Specifications (Tss) to Reflect an Expanded Operating Domain Resulting from Implementation of Average Power Range Monitor, Rod Block Monitor Tss/Maximum Extended Load Line Limit Analysis (Arts/Mellla) Project stage: Other ML0411203682004-05-17017 May 2004 Enclosure 14, 03/31/2004 Meeting Summary for Vermont Yankee. Slides Presentation Proposed Power Uprate Project stage: Meeting ML0411201272004-05-17017 May 2004 Category 3 Public Meeting Summary with Entergy Nuclear Operations Inc. to Discuss Proposed Power Uprate for Vermont Yankee Nuclear Power Station Project stage: Meeting ML0410603312004-05-17017 May 2004 Enclosures 3 - 13, 03/31/2004 Meeting Summary for Vermont Yankee Project stage: Meeting ML0414500202004-05-28028 May 2004 Request for Additional Information - Extended Power Uprate Project stage: RAI ML0331400252004-06-25025 June 2004 Vermont, Notice of Consideration of Issuance of Amendment to Facility Operating License for Extended Power Uprate and Opportunity for Hearing Project stage: Other ML0418100222004-06-25025 June 2004 Compliance with NRC Regulatory Compliance Project stage: Other ML0418104332004-06-29029 June 2004 06/29/04 E-mail - Compliance with NRC Regulatory Compliance Project stage: Other ML0420804642004-07-0202 July 2004 Letter Transmitting Vermont Yankee Nuclear Power Station, Technical Specification Proposed Change No. 263 - Supplement No. 8, Extended Power Uprate - Response to Request for Additional Information Project stage: Supplement ML0417400392004-07-0606 July 2004 Vermont Nuclear Power Station, Request for Additional Information, Extended Power Uprate. TAC No. MC0761 Project stage: RAI BVY 04-069, Technical Specification Proposed Change No. 262 - Supplement No. 13, Alternative Source Term - Standby Liquid Control System Check Valves2004-07-20020 July 2004 Technical Specification Proposed Change No. 262 - Supplement No. 13, Alternative Source Term - Standby Liquid Control System Check Valves Project stage: Request ML0422501402004-07-27027 July 2004 Technical Specification Proposed Change No. 263 - Supplement No. 9, Extended Power Uprate - Revised Containment Overpressure Envelope Project stage: Supplement 2004-01-07
[Table View] |
Text
November 19, 2003 LICENSEE:
Entergy Nuclear Vermont Yankee, LLC (ENVY) and Entergy Nuclear Operations, Inc. (ENO)
FACILITY:
Vermont Yankee Nuclear Power Station
SUBJECT:
SUMMARY
OF OCTOBER 30, 2003, CATEGORY 1 MEETING WITH ENVY AND ENO, TO DISCUSS ARTS/MELLLA, ALTERNATE SOURCE TERM, AND EXTENDED POWER UPRATE APPLICATIONS (TAC NOS. MB8070, MC0253, AND MC0761)
On October 30, 2003, a public meeting was held between the U.S. Nuclear Regulatory Commission (NRC), and representatives from ENVY and ENO (the licensees), at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss the licensees Average Power Range Monitor, Rod Block Monitor Technical Specifications/Maximum Extended Load Line Limit Analysis (ARTS/MELLLA),
Alternative Source Term (AST), and Extended Power Uprate (EPU) applications.
The licensee provided a brief summary of their AST and EPU applications along with application submittal dates, including MELLLA+, with desired NRC safety evaluation completion dates. (See the Agencywide Documents Access and Management System (ADAMS)
Accession number ML033040397 for presentation slides.)
The licensee will review their Appendix J exemption request, submitted as part of their AST application, to ensure the need for the request. The staff indicated that questions regarding the licensees use of the standby liquid control (SLC) system in their AST application may be available in about a month as the staff completes its generic review of the issue. The staff indicated that they will soon issue a request for additional information, as previously discussed with the licensee, regarding questions related to the AST application outside of the SLC issue.
The staff also asked the licensee to review their exemption request for Appendix J (which was part of the AST application) to confirm the applicability of their reference to another licensees exemption.
The NRC staff queried the licensee about several issues, including the apparent lack of completeness and level of detail in their technical and regulatory evaluation of the EPU application, and the need for quality documents along with timeliness of products so that the staff can maintain the review schedule. The staff will provide the licensee examples of the lack of completeness which was highlighted by several of the reviewers from various technical branches. The licensee stated that the steam dryer report(s) relating to EPU will be submitted in the near future. The staff is continuing its acceptability review of the EPU application.
The licensee and the NRC staff stated that they are continuing to review the concern regarding setpoint methodology for ARTS/MELLLA and EPU. It was noted by the staff that schedules for the completion of their review are impacted as this issue remains unresolved.
Public Meeting Forms were provided to the attendees. Any forms returned will be forwarded to the Office of the Executive Director for Operations.
A list of meeting attendees is enclosed.
If you have any additional inquiries, please contact me by phone at 301-415-3016, or by e-mail at rmp3@nrc.gov.
/RA/
Robert M. Pulsifer, Project Manager Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-271
Enclosure:
List of Meeting Attendees cc w/encl: See next page Public Meeting Forms were provided to the attendees. Any forms returned will be forwarded to the Office of the Executive Director for Operations.
A list of meeting attendees is enclosed.
If you have any additional inquiries, please contact me by phone at 301-415-3016, or by e-mail at rmp3@nrc.gov.
/RA/
Robert M. Pulsifer, Project Manager Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-271
Enclosure:
List of Meeting Attendees cc w/encl: See next page DISTRIBUTION:
PDI-2 R/F J. Clifford R. Pulsifer C. Raynor ADAMS Accession Numbers: Package: ML033100041; Meeting Summary: ML033100023; Sign-in Sheet: ML033100047 OFFICE PDI-2/PM PDI-2/LA PDI-2/SC NAME RPulsifer CRaynor VNerses for JClifford DATE 11/13/03 11/10/03 11/18/03 OFFICIAL RECORD COPY
Vermont Yankee Nuclear Power Station cc:
Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mr. David R. Lewis Shaw, Pittman, Potts & Trowbridge 2300 N Street, N.W.
Washington, DC 20037-1128 Ms. Christine S. Salembier, Commissioner Vermont Department of Public Service 112 State Street Montpelier, VT 05620-2601 Mr. Michael H. Dworkin, Chairman Public Service Board State of Vermont 112 State Street Montpelier, VT 05620-2701 Chairman, Board of Selectmen Town of Vernon P.O. Box 116 Vernon, VT 05354-0116 Mr. Michael Hamer Operating Experience Coordinator Vermont Yankee Nuclear Power Station 320 Governor Hunt Road Vernon, VT 05354 G. Dana Bisbee, Esq.
Deputy Attorney General 33 Capitol Street Concord, NH 03301-6937 Chief, Safety Unit Office of the Attorney General One Ashburton Place, 19th Floor Boston, MA 02108 Ms. Deborah B. Katz Box 83 Shelburne Falls, MA 01370 Mr. Raymond N. McCandless Vermont Department of Health Division of Occupational and Radiological Health 108 Cherry Street Burlington, VT 05402 Manager, Licensing Entergy Nuclear Vermont Yankee, LLC P.O. Box 0500 185 Old Ferry Road Brattleboro, VT 05302-0500 Resident Inspector Vermont Yankee Nuclear Power Station U. S. Nuclear Regulatory Commission P.O. Box 176 Vernon, VT 05354 Director, Massachusetts Emergency Management Agency ATTN: James Muckerheide 400 Worcester Rd.
Framingham, MA 01702-5399 Jonathan M. Block, Esq.
Main Street P.O. Box 566 Putney, VT 05346-0566 Mr. John Kelly Director, Nuclear Safety Assurance Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Gary Taylor Chief Executive Officer Entergy Operations 1340 Echelon Parkway Jackson, MS 39213
Vermont Yankee Nuclear Power Station cc:
Mr. John Herron Sr. VP and Chief Operating Officer Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Dan Pace Vice President, Engineering Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Randall Edington Vice President, Operations Support Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Director of Oversight Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. John M. Fulton Assistant General Counsel Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Jay K. Thayer Site Vice President Entergy Nuclear Operations, Inc.
Vermont Yankee Nuclear Power Station P.O. Box 0500 185 Old Ferry Road Brattleboro, VT 05302-0500 Mr. Ken L. Graesser BWR SRC Consultant 38832 N. Ashley Drive Lake Villa, IL 60046 Mr. Jim Sniezek BWR SRC Consultant 5486 Nithsdale Drive Salisbury, MD 21801 Mr. Ron Toole BWR SRC Consultant 605 West Horner Street Ebensburg, PA 15931 Ms. Stacey Lousteau Treasury Department Entergy Services, Inc.
639 Loyola Avenue, Mail Stop L-ENT-15E New Orleans, LA 70113 Mr. Michael Kansler President Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601