Nuclear Operating Company South Teo*s Prjtectkadrlc Generatlng Sat/on P0 Box28-9 Madsorth, Teras 77483 AA

-I-March 4, 2003 NOC-AE-03001483 File No: G25, T07.03 1 OCFR50.55a U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 South Texas Project Unit 2 Docket No. STN 50-499 Inservice Inspection Summary Reports for Repairs and Replacements and for System Pressure Tests - 2RE09 Enclosed are four copies of the South Texas Project Unit 2 inservice inspection summary reports for repairs and replacements and for system pressure tests performed prior to and during the ninth refueling outage (2RE09) completed in December 2002. These summary reports satisfy the reporting requirements of Section XI, Article IWA-6230.

If there are any questions, please contact either Michael S. Lashley at (361) 972-7523 or me at (361) 972-7786.

Alex P. Kent

Manager, Test/Program Engineering PLW

Enclosures:

1. 2RE09 Inservice Inspection Summary Report for Repairs and Replacements
2. 2RE09 Inservice Inspection Summary Report for System Pressure Tests

cc:

(paper copy)

(electronic copy)

  • Ellis W. Merschoff Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852
  • Richard A. Ratliff Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189
  • Cornelius F. O'Keefe U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483
  • L. D. Blaylock/W. C. Gunst City Public Service
  • Mohan C. Thadani U. S. Nuclear Regulatory Commission
  • A. Ramirez City of Austin
  • C. A. Johnson AEP Texas Central Company
  • Jon C. Wood Matthews & Branscomb
  • C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704
  • One copy of the attachment is provided.

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P.O. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19,1989 Prepared by:

E. Stauber, Engineer Reviewed by:

a I=

M.S. ashley, Supervising Engineer

SCOPE 2RE09 REPAIRS AND REPLACEMENTS The inspections and records summarized in this report were performed in accordance with Section Xl of the ASME Code, 1989 Edition with no Addenda, which is applicable to the South Texas Project, Unit 2.

This report covers ASME Code Class 1 and 2 pressure-retaining components and their supports where repair or replacement was performed between the end of the eighth refueling outage and the end of the ninth refueling outage just completed. This report is submitted in accordance with paragraph IWA-6230 of Section XI for ASME Code Class 1 and 2 pressure retaining components and their supports.

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-004 SG SG-370700 SG Primary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-005 SG SG-370703 SG Primary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-006 SG SG-370706 SG Primary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-007 SG SG-370709 SG Primary 1R122NSG201D Westinghouse 4FM2 81 Installed studs, nuts &

1/27/03 Manways washers 1

02-02-008 SG SG-370701 SG Secondary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-009 SG SG-370704 SG Secondary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-010 SG SG-370707 SG Secondary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-011 SG SG-370710 SG Secondary 1R122NSG201D Westinghouse 4FM2 81 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-022 SG SG-411247 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-023 SG SG-411248 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-024 SG SG-411249 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1_ _

1_

1_

1_ Lateral Supports I

I I

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-025 SG SG-411250 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-026 SG SG-411230 SG 1R122NSG201A Westinghouse 1FM2 78 Performed RCS 12/18/02 Nozzle Preps 1

02-02-027 SG SG-411231 SG 1R122NSG201B Westinghouse 2FM2 79 Performed RCS 12/18/02 Nozzle Preps 1

02-02-029 SG SG-411232 SG 1R122NSG201C Westinghouse 3FM2 80 Performed RCS 12/18/02 Nozzle Preps 1

02-02-030 SG SG-411233 SG 1R122NSG201D Westinghouse 4FM2 81 Performed RCS 12/18/02 Nozzle Preps 1

02-02-039 SG SG-411251 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-040 SG SG-411252 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-041 SG SG-411253 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-042 SG SG-411254 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-043 RC RC-411238 RCS Piping N/A Southwest Fab 19003/19004 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-044 RC RC-411239 RCS Piping N/A Southwest Fab 19007/19008 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-045 RC RC-411240 RCS Piping N/A Southwest Fab 19011/19012 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-046 RC RC-411241 RCS Piping N/A Southwest Fab 19015/19016 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-053 SG SG-411317 Steam 1 R122NSG201A Westinghouse 2151 29 Removed Old SG 12/4/02 Generator 1

02-02-054 SG SG-411318 Steam 1R122NSG201B Westinghouse 2152 30 Removed Old SG 12/4/02 Generator 1

02-02-055 SG SG-411319 Steam 1R122NSG201C Westinghouse 2153 31 Removed Old SG 12/4/02 Generator 1

02-02-056 SG SG-411320 Steam 1R122NSG201D Westinghouse 2154 32 Removed Old SG 12/4/02 Generator

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-064 SG SG-411322 Steam 1 R122NSG201A Westinghouse 1FM2 78 Installed New SG 12/18/02 Generator 1

02-02-065 SG SG-411323 Steam 1 R122NSG201B Westinghouse 2FM2 79 Installed New SG 12/18/02 Generator I

1 02-02-066 SG SG-411324 Steam 1 R1 22NSG201 C Westinghouse 3FM2 80 Installed New SG 12/18/02 Generator 1

02-02-067 SG SG-411325 Steam 1 R122NSG201D Westinghouse 4FM2 81 Installed New SG 12/18/02 Generator 1

02-02-069 SG SG-411243 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-070 SG SG-411244 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-071 SG SG-411245 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-072 SG SG-411246 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-078 RC PM:9800051 Valve N2RCPSV3450 Crosby N60491 667 Replaced valve 01/08/03 2/152216 0006 w/Crosby s/n: N60491 00-0008 1

02-02-079 RC PM:9800051 Valve N2RCPSV3451 Crosby N60491 621 Replaced valve 12/4/02 3/152217 0002 w/Crosby s/n: N60491 00-0009 1

02-02-080 RC PM:9800051 Valve N2RCPSV3452 Crosby N60491 620 Replaced valve 12/19/02 5/152218 0001 w/Crosby s/n: N60491 00-0005 1

02-02-090 RC RC-417273 RCP 2A 1 R132NPP201A Westinghouse 1599 46 Replaced #2 Cartridge 12/16/02 Seal Housing 1

02-02-102 SG SG-411446 SG 1 R122NSG201A Westinghouse 1FM2 78 Drill & Tap Covers 12/18/02 1

02-02-104 SG SG-411447 SG 1 R122NSG201B Westinghouse 2FM2 79 Drill & Tap Covers 12/18/02 1

02-02-105 SG SG-411448 SG 1R122NSG201C Westinghouse 3FM2 80 Drill & Tap Covers 12/18/02 1

02-02-106 SG SG-411449 SG 1 R122NSG201D Westinghouse 4FM2 81 Drill & Tap Covers 12/18/02

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION X1 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-109 RC RC-415162 Valve 1R142XRC0085 Westinghouse 04000GH880 W14 Replaced valve bonnet 12/18/02 000D005W7 659 50022 1

02-02-118 CV CV-422725 Valve 1 R172XCV0005 Westinghouse 04001CS880 W14 Repaired weld for 12/19/02 000D005W7 890 valve seal cap 50018 1

02-02-127 SG SG-370710 SG Secondary 1FR122NSG201D Westinghouse 4FM2 81 Replace handhole 01/29/03 Handhole cover 1

02-02-128 RC RC-410939 CRDM Pene #4 1R152NRD201A Westinghouse 48-W20 Seal weld build up.

1/8/2003 (K-8) 5055D47G01 506 M403 1

02-02-129 RC RC-410939 CRDM Pene #7 1R152NRD201A Westinghouse 56-W20 Replaced CRDM 1/8/2003 (K-10) 5055D47G01 514 housing. Seal weld M403 build up.

1 02-02-130 RC RC-410939 CRDM Pene 1R152NRD201A Westinghouse 40-W20 Seal weld build up.

1/8/2003

  1. 20 (L-5) 5055D47G01 498 M403 1

02-02-131 RC RC-414785 Valve 1 R142XRC0057A Kerotest CAB1 3-2 N/A Replaced valve 12/19/02 w/Kerotest s/n:

CAB20-20 1

02-02-137 RC RC-419141 Spring Can RC-2123-SH0002 NPSI RC-2123-N/A Repaired spring can.

1/21/03 SH02/0 2

02-00-005 MS PM:9700026 Valve N2MSPSV7430 Dresser BT-02188 N/A Replaced valve disc 12/16/02 6/127620 2

02-01-024 CV CV-415095 Heat Exchanger 5R172NHX202A Joseph Oats 2312-1B 987 Replaced channel 10/08/02 head studs and nuts 2

02-01-040 RH RH-410918 Pump 2R162NPA201A Pacific Pump 51734 363 Replaced pump oil 9/17/02 cooler cap screws 2

02-01-041 RH RH-410919 Pump 2R162NPA201B Pacific Pump 51735 364 Replaced pump cap 9/24/02 screws 2

02-02-028 CV PM:01 00065 Valve A2CVFCV0205 Copes-Vulcan 7620-95400-1675 Replace valve plug 2/19/03 4/232479 9-2 1

1

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-031 SG SG-411234 SG 1R122NSG201A Westinghouse 1FM2 78 Install Swage reducer 12/19/02 2

02-02-032 SG SG-411235 SG 1R122NSG201B Westinghouse 2FM2 79 Install Swage reducer 12/19/02 2

02-02-033 SG SG-411236 SG 1R122NSG201C Westinghouse 3FM2 80 Install Swage reducer 12/19/02 2

02-02-034 SG SG-411237 SG 1R122NSG201D Westinghouse 4FM2 81 Install Swage reducer 12/19/02 2

02-02-047 FW FW-411267 Pipe Spools FW-2012-Ebasco/Bechtel 38253/38295 N/A Replaced piping 12/9/02 H,J,JA,JB,JC,JD 2

02-02-048 FW FW-411270 Pipe Spools FW-2014-Ebasco/Bechtel 38296 N/A Replaced piping 12/12/02 J,JA,JB,JC 2

02-02-049 FW FW-411273 Pipe Spools FW-2016 L, Ebasco/Bechtel 24355 N/A Replaced piping 12/11/02 LA,LBLC,LD, LE 2

02-02-050 FW FW-411276 Pipe Spools FW-2018-Ebasco/Bechtel 38297 N/A Replaced piping 12/11/02 J,JA,JB,JC,JD 2

02-02-051 CV CV-411296 Pipe Spools CV-2002-C Ebasco/Bechtel 27147 N/A Replaced piping 12/19/02 2

02-02-052 CV CV-411296 Pipe Spools CV-2142-A-A3, Ebasco/Bechtel N/A N/A Replaced piping 12/19/02 B-A3 2

02-02-057 AF AF-411280 Pipe Spools AF-2008-H,GFA, Ebasco/Bechtel 39257/39256/

N/A Replaced piping 12/12/02 FB,HA,HB, AF-37354 2062-B,BA 2

02-02-058 AF AF-411282 Pipe Spools AF-2010-K,KA, Ebasco/Bechtel 37366 N/A Replaced piping 12/19/02 KB 2

02-02-059 AF AF-411285 Pipe Spools AF-2012-K,KA, Ebasco/Bechtel 37352 N/A Replaced piping 12/18/02 KB 2

02-02-060 AF AF-411288 Pipe Spools AF-2006-Ebasco/Bechtel 39253/39254/

N/A Replaced piping 12/11/02 N,HA,HB,HC, AF-37296 2061 -A,AA 2

02-02-061 AF AF-411283 Pipe Support AF201OHL5012 NPSI N/A N/A Replaced or modified 12/9/02 dead weight supports 2

02-02-062 AF AF-411284 Pipe Support AF2063HL5005 NPSI N/A N/A Replaced or modified 12/9/02 1

1 seismic restraints 2

02-02-063 AF AF-411287 Pipe Support AF2012HL5018 NPSI 3006-275F-N/A Remove and reweld 12/4/02 1

002-55 rear bracket

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-073 MS PM:0100762 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Replaced poppet/Pilot 1/24/03

/223792 poppet 2

02-02-074 MS MS-411259 Pipe Spools MS-2001 -GA2 Ebasco/Bechtel 38914/38915 N/A Removed/reinstalled 12/12/02 piping 2

02-02-075 MS MS-411261 Pipe Spools MS-2002-GA2 Ebasco/Bechtel 38863/38864 N/A Removed/reinstalled 12/17/02 piping 2

02-02-076 MS MS-411263 Pipe Spools MS-2003-GA2 Ebasco/Bechtel 38824/38825 N/A Removed/reinstalled 12/11/02 piping 2

02-02-077 MS MS-411265 Pipe Spools MS-2004-GA2 Ebasco/Bechtel 38907/38908 N/A Removed/reinstalled 12/16/02 piping 2

02-02-082 FW FW-411268 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5008, dead weight supports HL5014,HL5004 2

02-02-083 FW FW-411269 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/5/02 Supports

HL5012, seismic restraints HL5013,HL5015, HL5016 2

02-02-084 FW FW-411271 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

SHOO01, dead weight supports HL5006,HL5015 2

02-02-085 FW FW-411272 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5013, HL5014 seismic restraints 2

02-02-086 FW FW-411274 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5011, HL5017 dead weight supports 2

02-02-087 FW FW-411279 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports SHOO01 seismic restraints 2

02-02-088 FW FW-411277 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/19/02 Supports HL5014 dead weight supports 2

02-02-089 FW FW-411278 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5004, seismic restraints HL5016,SS0006 1

2 02-02-094 SB SB-411309 Pipe Spools SB-21 01, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2103 piping

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-095 SB SB-411311 Pipe Spools SB-2201, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2203 piping 2

02-02-096 SB SB-411313 Pipe Spools SB-2301, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2303 piping 2

02-02-097 SB SB-411315 Pipe Spools SB-2401, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2403 piping 2

02-02-098 SB SB-411444 Pipe Support SB2401HL5016U Ebasco 460 N/A Welded paddle to 1/6/03 flange 2

02-02-101 FW FW-422891 Valve A2FWFV7143 WKM 536744 2051 Installed Sealant 11/27/02 Injection Fitting 2

02-02-115 CV CV-397589 Snubber CV2088HL5002 Anchor Darling 755 N/A Replaced snubber 11/4/02 2

02-02-119 CV CV-413596 Valve 2R172TCV0191A Kerotest CAB1322 N/A Drilled out disc pin 11/27/02 hole 2

02-02-120 CV CV-413596 Valve 2R172TCV0191B Kerotest YG54 N/A Drilled out disc pin 11/27/02 hole 2

02-02-121 MS MS-426236 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Repaired indication on 12/19/02 valve sealing surface.

2 02-02-122 CV CV-416537 Valve C2CVHCV0218 Copes Vulcan 7620-95400-1047 Replaced valve plug 1/6/03 102 2

02-02-124 SB SB-411445 Snubber SB2401 HL5016L Anchor Darling 316 N/A Replaced snubber 11/27/02 w/Anchor Darling s/n:

511 2

02-02-125 CV PM:9000070 Valve N2CVPSV31 00 Crosby N662520000 1059 Replaced valve w/

2/17/03 5/198066 03 Crosby s/n N66252000004 2

02-02-134 SI SI-414196 Piping Spacer SI-2201 -N-1 Ebasco N/A N/A Machined spacer 11/27/02 surface, cut off and rewelded handle 2

02-02-135 CV CV-396831 Valve 2R172XCV0026 Westinghouse 04001 CS880 W14 Replaced valve 12/19/02 000D005W7 944 w/Westinghouse s/n:

50024 04001 CS880000D000 W750007

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-139 FW FW-423219 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-02-140 FW FW-427631 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-97-049 MS PM:9700025 Valve N2MSPSV7410 Dresser BT-02186 N/A Replaced valve disc 12/16/02 6/118592 1

2 02-97-053 MS PM:9700026 Valve N2MSPSV7410D Dresser BT-02202 N/A Replaced valve disc 12/16/02 0/118596 2

02-97-055 MS PM:9700026 Valve N2MSPSV7420A Dresser BT-02191 N/A Replaced valve disc 12/16/02 2/118598 2

02-97-058 MS PM:9700026 Valve N2MSPSV7420D Dresser BT-02203 N/A Replaced valve disc 12/18/02 5/118601 2

02-97-061 MS PM:9700026 Valve N2MSPSV7430C Dresser BT-02200 N/A Replaced valve disc 12/16/02 9/127623

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR SYSTEM PRESSURE TESTS (CLASS 1 AND 2)

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P. O. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19, 1989 Prepared by:

t*e-,

E J. E. St oer, Engineer Reviewed by:

M. S,/Lash!#, S pervising Engineer

SCOPE 2RE09 SYSTEM PRESSURE TESTS The examinations summarized in this report were performed in accordance with the 1989 Edition with no Addenda of the ASME Code,Section XI that is applicable to the South Texas Project, Unit 2. This report covers selected ASME Code Class 1 and 2 Systems/Components.

Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in IWB-2412 and IWC-2412 for ASME Code Class 1 and 2 Systems/Components.

All ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1, Examination Category B-P, which established the examination frequency at each refueling outage.

The ASME Code Class 2 Systems/Components were selected on a prorated basis. This prorated selection process will continue until all ASME Code Class 2 Systems/Components are examined in accordance with Table IWC-2500-1, Examination Category C-H. The examination category for ASME Code Class 2 Systems/Components establishes the examination frequency at each inspection period.

Page 1 of 3 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483 Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A Commercial Service Date 06/19/89

6. National Board Number for Unit N/A Components Inspected ASME CODE CLASS 1 PIPING AND COMPONENTS Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. X 11 in., (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form
1.
2.
3.
5.

7.

Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province Board No.

Serial No.

No.

REACTOR VESSEL COMBUSTION ENGR/

12173 N/A 22391 1 R102NRV201A WESTINGHOUSE (M)

STM. GENERATOR 2A WESTINGHOUSE (M) 2151 N/A 29 1R122NSG201A STM. GENERATOR 2B WESTINGHOUSE (M) 2152 N/A 30 1R122NSG201B STM. GENERATOR 2C WESTINGHOUSE (M) 2153 N/A 31 1 R1 22NSG201 C STM. GENERATOR 2D WESTINGHOUSE (M) 2154 N/A 32 1R122NSG201D PRESSURIZER 2A WESTINGHOUSE (M) 2161 N/A N/A 1R112NPZ201A RC PUMP 2A WESTINGHOUSE (M) 1-115E580G02 N/A 46 1 R132NPP201A I

RC PUMP 2B WESTINGHOUSE (M) 2-115E580G02 N/A 47 1 R132NPP201B RC PUMP2C WESTINGHOUSE (M) 3-115E580G02 N/A 48 1R132NPP201C RC PUMP 2D WESTINGHOUSE (M) 4-115E580G02 N/A 49 1R132NPP201D CLASS 1 PIPING EBASCO (I)

VARIOUS N/A N/A CLASS 1 VALVES VARIOUS VARIOUS N/A N/A

Page 2 of 3 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section Xl 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 3 of 3.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 3 of 3.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl, c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date 20 _._.Signed STP Nuclear Operatinq Company. By

,4--

4-^J,ý,/

Owner

£VM&WS..ashley Test Engineering Supervisor CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston, Rhode Island. have inspected the components described in this Owner's Report during the period 04/03/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage o a ss of any kind arising from or connected with this inspection.

Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State, Province, and Endorsements Date 20 03

Page 3 of 3 SUPPLEMENTAL PAGE FOR ASME CODE CLASS 1 PIPING AND COMPONENTS

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth. TX 77483

2.

Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit NIA
13.

ABSTRACT OF EXAMINATIONS AND TESTS A System Leakage Test as prescribed in IWA-521 1(a) for all ASME Code Class 1 Pressure Retaining Components was conducted in accordance with Table IWB-2500-1, Examination Category B-P, Item Nos. B15.10, B15.20, B15.30, B15.40, B15.50, B15.60, and B15.70.

The Pressure Test and VT-2 visual examinations were conducted in accordance with Plant Surveillance Pressure Test Procedure, OPSP15-RC-0001, Reactor Coolant System Leakage Pressure Test, at the conclusion of the ninth refueling outage. ASME Code Class 1 piping and valves are specifically identified in the above referenced procedure.

15.

ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN

.The Visual Examinations (VT-2) performed during the Pressure Test found minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined to be acceptable for continued operation. Appropriate corrective action was initiated to correct these leaks.

Page 1 of 5 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

2.

Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

NIA

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
7.

Components Inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

RCFC COILS 21A, 22A, American Air Filter Various N/A Various 21 B, 22B, 21 C, and 22C RHR 2A Ht. Exch.

Joseph Oats 2312-40 N/A 993 2R162NHX201A RHR Pump 2A Pacific Pumps 51734 N/A 363 2R162NPA201A RHR 2B Ht. Exch.

Joseph Oats 2312-4E N/A 994 2R162NHX201B RHR Pump 2B Pacific Pumps 51734 N/A 363 2R162NPA201B RHR 2C Ht. Exch.

Joseph Oats 2312-4F N/A 995 2R162NHX201C RHR Pump 2C Pacific Pumps 51736 NIA 365 2R162NPA201C CVCS Seal Water Lamco 833 N/A 256 Return Ht. Exch.

4R172NHX204A CVCS Letdown Ht.

Joseph Oats 2312-1 B N/A 987 Exch.

5R172NHX202A CVCS Excess Letdown Joseph Oats 2312-3B N/A 989 Ht. Exch.

5R172NHX203A Volume Control Tank 2A Reco Industries N-2287.10 N/A 76881 2R172NTS201A Suction Pulsation Johnson Controls Inc M-0439 N/A 177 Dampener Htr 2R172NPD201A CVCS Seal Injection Ptrinity 35364 N/A 19022 Filter 2A 2R172NFR202A CVCS Seal Injection Ptrinity 35365 N/A 19023 Filter 2B 2R172NFR202B 4, ? -/,1-0 ý?

Page 2 of 5 Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Centrifugal Charging Dresser Industries, Inc 51901 N/A 429 Pump 2A 2R172NPA201A Centrifugal Charging Dresser Industries, Inc 51902 N/A 430 Pump 2B 2R172NPA201IB Positive Displacement Union Pump Company N753718A602 N/A N/A Pump 2R172NPA202A Pulsation Dampener Johnson Controls Inc M-0440 N/A 178 2R172NPD202A CVCS Seal Injection Ptrinity 35959 N/A 19482 Filter 2B 2R172NFR2011B CVCS RC Filter 2A Ptrinity 35958 N/A 19481 2R172NFR201A CVCS Seal Water Ptrinity 35960 N/A 19483 Return Filter

.2R172NFR203A Seal Water Hx Lamco 833 N/A 256 4R172NHX204A Letdown Hx 2A Joseph Oat Corp 2312-1 B N/A 987 5R172NHX202A Regen Letdn Hx Joseph Oat Corp J-2312-2B N/A 985 5R192NHX203A Regen Hx 2A Joseph Oat Corp 2380-1 B N/A 2052 2R172NHX201A CVCS Excess Letdown Joseph Oat Corp 2312-3B N/A 989 Ht Exch 2A 5R172NHX203A RHR HX 2A Joseph Oat Corp 2312-4D N/A 993 2R162NHX201A RHR HX 2B Joseph Oat Corp 2312-4E N/A 994 2R1 62NHX201 B RHR HX 2C Joseph Oat Corp 2312-4F N/A 995 2R162NHX201C RHR PUMP 2A Pacific Pump 51734 N/A 363 2R162NPA201A RHR PUMP 2B Pacific Pump 51735 N/A 364 2R162NPA201B RHR PUMP2C Pacific Pump 51736 N/A 365 2R162NPA201C I

II 4-2-/9-e3

Page 3 of 5 Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

STM. GENERATOR 2A WESTINGHOUSE (M) 2151 N/A 29 1R122NSG201A STM. GENERATOR 2B WESTINGHOUSE (M) 2152 N/A 30 1R122NSG201B STM. GENERATOR 2C WESTINGHOUSE (M) 2153 N/A 31 1R122NSG201C STM. GENERATOR 2D WESTINGHOUSE (M) 2154 N/A 32 1 R122NSG201D ASSOC. CLASS 2 EBASCO (I)

VARIOUS N/A N/A PIPING ASSOC. CLASS 2 VARIOUS VARIOUS N/A N/A VALVES Note:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page 4 of 5 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section XI 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 5 of 5.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 5 of 5.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date 20 0)

Signed STP Nuclear Operating Company. By e-//4 W

i'*

I.kU7 KAIyvI ench Test Engineering Supervisor CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston Rhode Island, have inspected the components described in this Owner's Report during the period 04/03/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a os of any kind arising from or connected with this inspection.

Commissions TX-826 National Board, State, Province, and Endorsements B. R. Russell, Inspector's Signature Date 20-0?

UVl VI

Page 5 of 5 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

2.

Plant South Texas Proiect Electric Generating Station, P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
13. ABSTRACT OF EXAMINATIONS System Functional and Inservice Pressure Tests as prescribed by IWA-5211 (b) and (c), respectively, were conducted on selected ASME Code Class 2 pressure retaining components in accordance with Table IWC-2500-1, Examination Category C-H, Item Nos. C7.1 0, C7.30, C7.50 and C7.70.

The Pressure Tests and VT-2 visual examinations were conducted during the first period of examination of the second interval in accordance with the following Plant Surveillance Pressure Test Procedures:

OPSP15-CC-0001 Component Cooling Water System Inservice Pressure Test OPSP15-CV-0001 Chemical Volume Control System Inservice Pressure Test OPSP15-CV-0007 Chemical Volume Control System Inservice Pressure Test OPSP15-FC-0001 Spent Fuel Pool Cooling & Cleaning System Inservice Pressure Test OPSP15-RH-0001 Residual Heat Removal System Inservice Pressure Test ASME Code Class 2 piping and valves are specifically identified in the above referenced procedures.

15. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined acceptable for continued system operation. Appropriate corrective action was initiated to correct these leaks.

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P.O. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19,1989 Prepared by:

E. Stauber, Engineer Reviewed by:

a, YMS. ashley-, Supervising Engineer /

SCOPE 2RE09 REPAIRS AND REPLACEMENTS The inspections and records summarized in this report were performed in accordance with Section XI of the ASME Code, 1989 Edition with no Addenda, which is applicable to the South Texas Project, Unit 2.

This report covers ASME Code Class 1 and 2 pressure-retaining components and their supports where repair or replacement was performed between the end of the eighth refueling outage and the end of the ninth refueling outage just completed. This report is submitted in accordance with paragraph IWA-6230 of Section XI for ASME Code Class 1 and 2 pressure retaining components and their supports.

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-004 SG SG-370700 SG Primary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-005 SG SG-370703 SG Primary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-006 SG SG-370706 SG Primary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-007 SG SG-370709 SG Primary 1R122NSG201D Westinghouse 4FM2 81 Installed studs, nuts &

1/27/03 Manways washers 1

02-02-008 SG SG-370701 SG Secondary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-009 SG SG-370704 SG Secondary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-010 SG SG-370707 SG Secondary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-011 SG SG-370710 SG Secondary 1R122NSG201D Westinghouse 4FM2 81 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-022 SG SG-411247 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-023 SG SG-411248 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports I

1 02-02-024 SG SG-411249 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports I

I _

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION

- IDENTITY WORK DATE (TAG TPNS) 1 02-02-025 SG SG-411250 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-026 SG SG-411230 SG 1R122NSG201A Westinghouse 1FM2 78 Performed RCS 12/18/02 Nozzle Preps 1

02-02-027 SG SG-411231 SG 1 R122NSG201B Westinghouse 2FM2 79 Performed RCS 12/18/02 Nozzle Preps 1

02-02-029 SG SG-411232 SG 1R122NSG201C Westinghouse 3FM2 80 Performed RCS 12/18/02 Nozzle Preps 1

02-02-030 SG SG-411233 SG 1R122NSG201D Westinghouse 4FM2 81 Performed RCS 12/18/02 Nozzle Preps 1

02-02-039 SG SG-411251 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-040 SG SG-411252 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-041 SG SG-411253 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-042 SG SG-411254 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-043 RC RC-411238 RCS Piping N/A Southwest Fab 19003/19004 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-044 RC RC-411239 RCS Piping N/A Southwest Fab 19007/19008 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-045 RC RC-411240 RCS Piping N/A Southwest Fab 19011/19012 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-046 RC RC-411241 RCS Piping N/A Southwest Fab 19015/19016 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-053 SG SG-411317 Steam 1R122NSG201A Westinghouse 2151 29 Removed Old SG 12/4/02 Generator 1

02-02-054 SG SG-411318 Steam 1R122NSG201B Westinghouse 2152 30 Removed Old SG 12/4/02 Generator 1

02-02-055 SG SG-411319 Steam 1R122NSG201C Westinghouse 2153 31 Removed Old SG 12/4/02 1

Generator II 1

02-02-056 SG SG-411320 Steam 1 R122NSG201 D Westinghouse 2154 32 Removed Old SG 12/4/02 Generator I

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-064 SG SG-411322 Steam 1R122NSG201A Westinghouse 1FM2 78 Installed New SG 12/18/02 Generator 1

02-02-065 SG SG-411323 Steam 1R122NSG201B Westinghouse 2FM2 79 Installed New SG 12/18/02 Generator 1

02-02-066 SG SG-411324 Steam 1R122NSG201C Westinghouse 3FM2 80 Installed New SG 12/18/02 Generator 1

02-02-067 SG SG-411325 Steam 1R122NSG201D Westinghouse 4FM2 81 Installed New SG 12/18/02 Generator 1

02-02-069 SG SG-411243 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-070 SG SG-411244 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-071 SG SG-411245 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-072 SG SG-411246 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-078 RC PM:9800051 Valve N2RCPSV3450 Crosby N60491 667 Replaced valve 01/08/03 2/152216 0006 w/Crosby s/n: N60491 00-0008 1

02-02-079 RC PM:9800051 Valve N2RCPSV3451 Crosby N60491 621 Replaced valve 12/4/02 3/152217 0002 w/Crosby s/n: N60491 00-0009 1

02-02-080 RC PM:9800051 Valve N2RCPSV3452 Crosby N60491 620 Replaced valve 12/19/02 5/152218 0001 w/Crosby s/n: N60491 00-0005 1

02-02-090 RC RC-417273 RCP 2A 1R132NPP201A Westinghouse 1599 46 Replaced #2 Cartridge 12/16/02 Seal Housing 1

02-02-102 SG SG-411446 SG 1R122NSG201A Westinghouse 1FM2 78 Drill & Tap Covers 12/18/02 1

02-02-104 SG SG-411447 SG 1R122NSG201B Westinghouse 2FM2 79 Drill & Tap Covers 12/18/02 1

02-02-105 SG SG-411448 SG 1R122NSG201C Westinghouse 3FM2 80 Drill & Tap Covers 12/18/02 1

02-02-106 SG SG-411449 SG 1 R1 22NSG201 D Westinghouse 4FM2 81 Drill & Tap Covers 12/18/02

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-109 RC RC-415162 Valve 1R142XRC0085 Westinghouse 04000GH880 W14 Replaced valve bonnet 12/18/02 000D005W7 659 50022 1

02-02-118 CV CV-422725 Valve 1 R1 72XCV0005 Westinghouse 04001 CS880 W14 Repaired weld for 12/19/02 000D005W7 890 valve seal cap 50018 1

02-02-127 SG SG-370710 SG Secondary 1 R122NSG201D Westinghouse 4FM2 81 Replace handhole 01/29/03 Handhole cover 1

02-02-128 RC RC-410939 CRDM Pene #4 1R152NRD201A Westinghouse 48-W20 Seal weld build up.

1/8/2003 (K-8) 5055D47G01 506 M403 1

02-02-129 RC RC-410939 CRDM Pene #7 1R152NRD201A Westinghouse 56-W20 Replaced CRDM 1/8/2003 (K-1 0) 5055D47G01 514 housing. Seal weld M403 build up.

1 02-02-130 RC RC-410939 CRDM Pene 1R152NRD201A Westinghouse 40-W20 Seal weld build up.

1/8/2003

  1. 20 (L-5) 5055D47G01 498 M403 1

02-02-131 RC RC-414785 Valve 1R142XRC0057A Kerotest CAB1 3-2 N/A Replaced valve 12/19/02 w/Kerotest s/n:

CAB20-20 1

02-02-137 RC RC-419141 Spring Can RC-2123-SH0002 NPSI RC-2123-N/A Repaired spring can.

1/21/03 SH02/0 2

02-00-005 MS PM:9700026 Valve N2MSPSV7430 Dresser BT-02188 N/A Replaced valve disc 12/16/02 6/127620 2

02-01-024 CV CV-415095 Heat Exchanger 5R1 72NHX202A Joseph Oats 2312-1 B 987 Replaced channel 10/08/02 head studs and nuts 2

02-01-040 RH RH-410918 Pump 2R162NPA201A Pacific Pump 51734 363 Replaced pump oil 9/17/02 cooler cap screws 2

02-01-041 RH RH-410919 Pump 2R162NPA201B Pacific Pump 51735 364 Replaced pump cap 9/24/02 screws 2

02-02-028 CV PM:01 00065 Valve A2CVFCV0205 Copes-Vulcan 7620-95400-1675 Replace valve plug 2/19/03 1

4/232479 1

9-2

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-031 SG SG-411234 SG 1R122NSG201A Westinghouse 1FM2 78 Install Swage reducer 12/19/02 2

02-02-032 SG SG-411235 SG 1R122NSG201B Westinghouse 2FM2 79 Install Swage reducer 12/19/02 2

02-02-033 SG SG-411236 SG 1R122NSG201C Westinghouse 3FM2 80 Install Swage reducer 12/19/02 2

02-02-034 SG SG-411237 SG 1R122NSG201D Westinghouse 4FM2 81 Install Swage reducer 12/19/02 2

02-02-047 FW FW-411267 Pipe Spools FW-2012-Ebasco/Bechtel 38253/38295 N/A Replaced piping 12/9/02 H,J,JA,JB,JC,JD 2

02-02-048 FW FW-411270 Pipe Spools FW-2014-Ebasco/Bechtel 38296 N/A Replaced piping 12/12/02 J,JA,JB,JC 2

02-02-049 FW FW-411273 Pipe Spools FW-2016 L, Ebasco/Bechtel 24355 N/A Replaced piping 12/11/02 LA,LB,LC,LD, LE 2

02-02-050 FW FW-411276 Pipe Spools FW-2018-Ebasco/Bechtel 38297 N/A Replaced piping 12/11/02 J,JA,JB,JC,JD 2

02-02-051 CV CV-411296 Pipe Spools CV-2002-C Ebasco/Bechtel 27147 N/A Replaced piping 12/19/02 2

02-02-052 CV CV-411296 Pipe Spools CV-2142-A-A3, Ebasco/Bechtel N/A N/A Replaced piping 12/19/02 B-A3 2

02-02-057 AF AF-411280 Pipe Spools AF-2008-H,G,FA, Ebasco/Bechtel 39257/39256/

N/A Replaced piping 12/12/02 FB,HA,HB, AF-37354 2062-B,BA 2

02-02-058 AF AF-411282 Pipe Spools AF-2010-K,KA, Ebasco/Bechtel 37366 N/A Replaced piping 12/19/02 KB 2

02-02-059 AF AF-411285 Pipe Spools AF-2012-K,KA, Ebasco/Bechtel 37352 N/A Replaced piping 12/18/02 KB 2

02-02-060 AF AF-411288 Pipe Spools AF-2006-Ebasco/Bechtel 39253/39254/

N/A Replaced piping 12/11/02 N,HA,HB,HC, AF-37296 2061 -A,AA 2

02-02-061 AF AF-411283 Pipe Support AF201OHL5012 NPSI N/A N/A Replaced or modified 12/9/02 dead weight supports 2

02-02-062 AF AF-411284 Pipe Support AF2063HL5005 NPSI N/A N/A Replaced or modified 12/9/02 1__

1seismic restraints 2

02-02-063 AF AF-411287 Pipe Support AF2012HL5018 NPSI 3006-275F-N/A Remove and reweld 12/4/02 1

1 002-55 rear bracket

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-073 MS PM:0100762 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Replaced poppet/Pilot 1/24/03

/223792 poppet 2

02-02-074 MS MS-411259 Pipe Spools MS-2001-GA2 Ebasco/Bechtel 38914/38915 N/A Removed/reinstalled 12/12/02 piping 2

02-02-075 MS MS-411261 Pipe Spools MS-2002-GA2 Ebasco/Bechtel 38863/38864 N/A Removed/reinstalled 12/17/02 1_

piping 2

02-02-076 MS MS-411263 Pipe Spools MS-2003-GA2 Ebasco/Bechtel 38824/38825 N/A Removed/reinstalled 12/11/02 piping 2

02-02-077 MS MS-411265 Pipe Spools MS-2004-GA2 Ebasco/Bechtel 38907/38908 N/A Removed/reinstalled 12/16/02 piping 2

02-02-082 FW FW-411268 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5008, dead weight supports HL5014,HL5004 2

02-02-083 FW FW-411269 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/5/02 Supports

HL5012, seismic restraints HL5013,HL5015, HL5016 2

02-02-084 FW FW-411271 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

SHOO01, dead weight supports HL5006,HL5015 2

02-02-085 FW FW-411272 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5013, HL5014 seismic restraints 2

02-02-086 FW FW-411274 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5011, HL5017 dead weight supports 2

02-02-087 FW FW-411279 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports SHOO01 seismic restraints 2

02-02-088 FW FW-411277 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/19/02 Supports HL5014 dead weight supports 2

02-02-089 FW FW-411278 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5004, seismic restraints HL5016,SS0006 2

02-02-094 SB SB-411309 Pipe Spools SB-2101, Ebasco N/A N/A Removed/reinstalled 12/18/02 1

SB2103 piping

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-095 SB SB-411311 Pipe Spools SB-2201, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2203 piping 2

02-02-096 SB SB-411313 Pipe Spools SB-2301, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2303 piping 2

02-02-097 SB SB-411315 Pipe Spools SB-2401, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2403 piping 2

02-02-098 SB SB-411444 Pipe Support SB2401HL5016U Ebasco 460 N/A Welded paddle to 1/6/03 flange 2

02-02-101 FW FW-422891 Valve A2FWFV7143 WKM 536744 2051 Installed Sealant 11/27/02 Injection Fitting 2

02-02-115 CV CV-397589 Snubber CV2088HL5002 Anchor Darling 755 N/A Replaced snubber 11/4/02 2

02-02-119 CV CV-413596 Valve 2R172TCV0191A Kerotest CAB1322 N/A Drilled out disc pin 11/27/02 hole 2

02-02-120 CV CV-413596 Valve 2R172TCV0191B Kerotest YG54 N/A Drilled out disc pin 11/27/02 hole 2

02-02-121 MS MS-426236 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Repaired indication on 12/19/02 valve sealing surface.

2 02-02-122 CV CV-416537 Valve C2CVHCV0218 Copes Vulcan 7620-95400-1047 Replaced valve plug 1/6/03 102 2

02-02-124 SB SB-411445 Snubber SB2401HL5016L Anchor Darling 316 N/A Replaced snubber 11/27/02 w/Anchor Darling s/n:

511 2

02-02-125 CV PM:9000070 Valve N2CVPSV31 00 Crosby N662520000 1059 Replaced valve w/

2/17/03 5/198066 03 Crosby s/n N66252000004 2

02-02-134 SI SI-414196 Piping Spacer SI-2201 -N-1 Ebasco N/A N/A Machined spacer 11/27/02 surface, cut off and rewelded handle 2

02-02-135 CV CV-396831 Valve 2R172XCV0026 Westinghouse 04001 CS880 W14 Replaced valve 12/19/02 000D005W7 944 wWestinghouse s/n:

50024 04001 CS880000DOOO I_

I_

I_

I I

W750007

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-139 FW FW-423219 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-02-140 FW FW-427631 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-97-049 MS PM:9700025 Valve N2MSPSV7410 Dresser BT-02186 N/A Replaced valve disc 12/16/02 6/118592 2

02-97-053 MS PM:9700026 Valve N2MSPSV741OD Dresser BT-02202 N/A Replaced valve disc 12/16/02 0/118596 2

02-97-055 MS PM:9700026 Valve N2MSPSV7420A Dresser BT-02191 N/A Replaced valve disc 12/16/02 2/118598 2

02-97-058 MS PM:9700026 Valve N2MSPSV7420D Dresser BT-02203 N/A Replaced valve disc 12/18/02 5/118601 2

02-97-061 MS PM:9700026 Valve N2MSPSV7430C Dresser BT-02200 N/A Replaced valve disc 12/16/02 1 _9/127623

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR SYSTEM PRESSURE TESTS (CLASS 1 AND 2)

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P. 0. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19,1989 Prepared by:.

Reviewed by: M. S as-t e, S e M. S,/ash,#

~prising Engineer X*'/

SCOPE 2RE09 SYSTEM PRESSURE TESTS The examinations summarized in this report were performed in accordance with the 1989 Edition with no Addenda of the ASME Code,Section XI that is applicable to the South Texas Project, Unit 2. This report covers selected ASME Code Class 1 and 2 Systems/Components.

Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in IWB-2412 and IWC-2412 for ASME Code Class 1 and 2 Systems/Components.

All ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1, Examination Category B-P, which established the examination frequency at each refueling outage.

The ASME Code Class 2 Systems/Components were selected on a prorated basis. This prorated selection process will continue until all ASME Code Class 2 Systems/Components are examined in accordance with Table IWC-2500-1, Examination Category C-H. The examination category for ASME Code Class 2 Systems/Components establishes the examination frequency at each inspection period.

Page 1 of 3 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483 Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A Commercial Service Date 06/19/89

6. National Board Number for Unit N/A Components Inspected ASME CODE CLASS 1 PIPING AND COMPONENTS Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. X 11 in., (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 4L- -& -
1.
2.
3.
5.

7.

Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province Board No.

Serial No.

No.

REACTOR VESSEL COMBUSTION ENGR/

12173 N/A 22391 1 R102NRV201A WESTINGHOUSE (M)

STM. GENERATOR 2A WESTINGHOUSE (M) 2151 N/A 29 1R122NSG201A STM. GENERATOR 2B WESTINGHOUSE (M) 2152 N/A 30 1R122NSG201B STM. GENERATOR 2C WESTINGHOUSE (M) 2153 N/A 31 1R122NSG201C STM. GENERATOR 2D WESTINGHOUSE (M) 2154 N/A 32 1R122NSG201D PRESSURIZER 2A WESTINGHOUSE (M) 2161 N/A N/A 1R112NPZ201A RC PUMP 2A WESTINGHOUSE (M) 1-115E580G02 N/A 46 1R132NPP201A RC PUMP 2B WESTINGHOUSE (M) 2-115E580G02 N/A 47 1R132NPP201B RC PUMP 2C WESTINGHOUSE (M) 3-115E580G02 N/A 48 1R132NPP201C RC PUMP 2D WESTINGHOUSE (M) 4-115E580G02 N/A 49 1R132NPP201D CLASS 1 PIPING EBASCO (I)

VARIOUS N/A N/A CLASS 1 VALVES VARIOUS VARIOUS N/A N/A

Page 2 of 3 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section XI 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 3 of 3.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 3 of 3.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date 20 0.*_Signed STP Nuclear Operating Company. By Owner iMYS. tashley Test Engineering Supervisor CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston, Rhode Island. have inspected the components described in this Owner's Report during the period 04/03/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage o a ss of any kind arising from or connected with this inspection.

Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State, Province, and Endorsements Date 101_b9 20 03

Page 3 of 3 SUPPLEMENTAL PAGE FOR ASME CODE CLASS 1 PIPING AND COMPONENTS

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483

2.

Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
13.

ABSTRACT OF EXAMINATIONS AND TESTS A System Leakage Test as prescribed in IWA-521 1(a) for all ASME Code Class 1 Pressure Retaining Components was conducted in accordance with Table IWB-2500-1, Examination Category B-P, Item Nos. B15.10, B15.20, B15.30, B15.40, B15.50, B15.60, and B15.70.

The Pressure Test and VT-2 visual examinations were conducted in accordance with Plant Surveillance Pressure Test Procedure, OPSP15-RC-0001, Reactor Coolant System Leakage Pressure Test, at the conclusion of the ninth refueling outage. ASME Code Class 1 piping and valves are specifically identified in the above referenced procedure.

15.

ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during the Pressure Test found minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined to be acceptable for continued operation. Appropriate corrective action was initiated to correct these leaks.

Page 1 of 5 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

2.

Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
7.

Components Inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

RCFC COILS 21A, 22A, American Air Filter Various N/A Various 21 B, 22B, 21 C, and 22C RHR 2A Ht. Exch.

Joseph Oats 2312-4D N/A 993 2R162NHX201A RHR Pump 2A Pacific Pumps 51734 N/A 363 2R162NPA201A RHR 2B Ht. Exch.

Joseph Oats 2312-4E N/A 994 2R162NHX201B RHR Pump 2B Pacific Pumps 51734 N/A 363 2R162NPA201B RHR 2C Ht. Exch.

Joseph Oats 2312-4F N/A 995 2R162NHX201C RHR Pump 2C Pacific Pumps 51736 N/A 365 2R162NPA201C CVCS Seal Water Lamco 833 N/A 256 Return Ht. Exch.

4R172NHX204A CVCS Letdown Ht.

Joseph Oats 2312-1 B N/A 987 Exch.

5RI72NHX202A CVCS Excess Letdown Joseph Oats 2312-3B N/A 989 Ht. Exch.

5R172NHX203A Volume Control Tank 2A Reco Industries N-2287.10 N/A 76881 2R172NTS201A Suction Pulsation Johnson Controls Inc M-0439 N/A 177 Dampener Htr 2R172NPD201A CVCS Seal Injection Ptrinity 35364 N/A 19022 Filter 2A 2R172NFR202A CVCS Seal Injection Ptrinity 35365 N/A 19023 Filter 2B 2R172NFR202B

Page 2 of 5 Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Centrifugal Charging Dresser Industries, Inc 51901 N/A 429 Pump 2A 2R172NPA201A Centrifugal Charging Dresser Industries, Inc 51902 N/A 430 Pump 2B 2R1 72NPA2011B Positive Displacement Union Pump Company N753718A602 N/A N/A Pump 2R172NPA202A Pulsation Dampener Johnson Controls Inc M-0440 N/A 178 2R172NPD202A CVCS Seal Injection Ptrinity 35959 N/A 19482 Filter 2B 2R172NFR2011B CVCS RC Filter 2A Ptrinity 35958 N/A 19481 2R172NFR201A CVCS Seal Water Ptrinity 35960 N/A 19483 Return Filter 2R172NFR203A Seal Water Hx Lamco 833 N/A 256 4R172NHX204A Letdown Hx 2A Joseph Oat Corp 2312-1 B N/A 987 5R172NHX202A Regen Letdn Hx Joseph Oat Corp J-2312-2B N/A 985 5R192NHX203A Regen Hx 2A Joseph Oat Corp 2380-1 B N/A 2052 2R172NHX201A CVCS Excess Letdown Joseph Oat Corp 2312-3B N/A 989 Ht Exch 2A 5R172NHX203A RHR HX 2A Joseph Oat Corp 2312-4D N/A 993 2R162NHX201A RHR HX 2B Joseph Oat Corp 2312-4E N/A 994 2R162NHX201lB RHR HX 2C Joseph Oat Corp 2312-4F N/A 995 2R162NHX201C RHR PUMP 2A Pacific Pump 51734 N/A 363 2R162NPA201A RHR PUMP 2B Pacific Pump 51735 N/A 364 2R1 62NPA2011B RHR PUMP 2C Pacific Pump 51736 N/A 365 2R162NPA201C

e-

-'

Page 3 of 5 Component or Appurtenance STM. GENERATOR 2A 1 R122NSG201A STM. GENERATOR 2B 1R122NSG201B STM. GENERATOR 2C 1R122NSG201C STM. GENERATOR 2D 1 R122NSG201D ASSOC. CLASS 2 PIPING ASSOC. CLASS 2 VALVES Note:

-. 4-

-. 4-Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

41-Z -"f -,-, -3

Page 4 of 5 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section XI 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 5 of 5.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 5 of 5.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date 1-/%/4'L 20*

0)Signed STP Nuclear Operating Company. By

'1*

Owner M

. Lashley Test Engineering Supervisor CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston.

Rhode Island. have inspected the components described in this Owner's Report during the period 04/03/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a os of any kind arising from or connected with this inspection.

Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State, Province, and Endorsements Date

,-/-

20 0:

Page 5 of 5 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS

.1. Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

2.

Plant South Texas Proiect Electric Generating Station, P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
13. ABSTRACT OF EXAMINATIONS System Functional and Inservice Pressure Tests as prescribed by IWA-5211 (b) and (c), respectively, were conducted on selected ASME Code Class 2 pressure retaining components in accordance with Table IWC-2500-1, Examination Category C-H, Item Nos. C7.1 0, C7.30, C7.50 and C7.70.

The Pressure Tests and VT-2 visual examinations were conducted during the first period of examination of the second interval in accordance with the following Plant Surveillance Pressure Test Procedures:

0PSP1 5-CC-0001 Component Cooling Water System Inservice Pressure Test OPSP15-CV-0001 Chemical Volume Control System Inservice Pressure Test OPSP15-CV-0007 Chemical Volume Control System Inservice Pressure Test OPSP15-FC-0001 Spent Fuel Pool Cooling & Cleaning System Inservice Pressure Test OPSP15-RH-0001 Residual Heat Removal System Inservice Pressure Test ASME Code Class 2 piping and valves are specifically identified in the above referenced procedures.

15. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined acceptable for continued system operation. Appropriate corrective action was initiated to correct these leaks.

0 - q :?

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P.O. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19, 1989 Prepared by:

Reviewed by:

ME. Stauber, Engineer lfM.S.fashrley-, Supervising Engineer /

SCOPE 2RE09 REPAIRS AND REPLACEMENTS The inspections and records summarized in this report were performed in accordance with Section XI of the ASME Code, 1989 Edition with no Addenda, which is applicable to the South Texas Project, Unit 2.

This report covers ASME Code Class 1 and 2 pressure-retaining components and their supports where repair or replacement was performed between the end of the eighth refueling outage and the end of the ninth refueling outage just completed. This report is submitted in accordance with paragraph IWA-6230 of Section XI for ASME Code Class 1 and 2 pressure retaining components and their supports.

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION Xl 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-004 SG SG-370700 SG Primary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-005 SG SG-370703 SG Primary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-006 SG SG-370706 SG Primary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-007 SG SG-370709 SG Primary 1R122NSG201D Westinghouse 4FM2 81 Installed studs, nuts &

1/27/03 Manways washers 1

02-02-008 SG SG-370701 SG Secondary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-009 SG SG-370704 SG Secondary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-010 SG SG-370707 SG Secondary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-011 SG SG-370710 SG Secondary 1R122NSG201D Westinghouse 4FM2 81 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-022 SG SG-411247 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-023 SG SG-411248 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-024 SG SG-411249 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1_

N/AWestinghouse______III

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-025 SG SG-411250 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-026 SG SG-411230 SG 1R122NSG201A Westinghouse 1FM2 78 Performed RCS 12/18/02 Nozzle Preps 1

02-02-027 SG SG-411231 SG 1 R1 22NSG201 B Westinghouse 2FM2 79 Performed RCS 12/18/02 Nozzle Preps 1

02-02-029 SG SG-411232 SG 1R122NSG201C Westinghouse 3FM2 80 Performed RCS 12/18/02 Nozzle Preps 1

02-02-030 SG SG-411233 SG 1R122NSG201D Westinghouse 4FM2 81 Performed RCS 12/18/02 Nozzle Preps 1

02-02-039 SG SG-411251 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-040 SG SG-411252 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-041 SG SG-411253 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-042 SG SG-411254 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-043 RC RC-411238 RCS Piping N/A Southwest Fab 19003/19004 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-044 RC RC-411239 RCS Piping N/A Southwest Fab 19007/19008 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-045 RC RC-411240 RCS Piping N/A Southwest Fab 19011/19012 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-046 RC RC-411241 RCS Piping N/A Southwest Fab 19015/19016 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-053 SG SG-411317 Steam 1 R1 22NSG201 A Westinghouse 2151 29 Removed Old SG 12/4/02 Generator 1

02-02-054 SG SG-411318 Steam 1R122NSG201B Westinghouse 2152 30 Removed Old SG 12/4/02 Generator 1

02-02-055 SG SG-411319 Steam 1R122NSG201C Westinghouse 2153 31 Removed Old SG 12/4/02 Generator 1

02-02-056 SG SG-411320 Steam 1R122NSG201D Westinghouse 2154 32 Removed Old SG 12/4/02 Generator I

I

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-064 SG SG-411322 Steam 1R122NSG201A Westinghouse 1FM2 78 Installed New SG 12/18/02 Generator 1

02-02-065 SG SG-411323 Steam 1 R122NSG201B Westinghouse 2FM2 79 Installed New SG 12/18/02 Generator 1

02-02-066 SG SG-411324 Steam 1R122NSG201C Westinghouse 3FM2 80 Installed New SG 12/18/02 Generator 1

02-02-067 SG SG-411325 Steam 1 R122NSG201D Westinghouse 4FM2 81 Installed New SG 12/18/02 Generator 1

02-02-069 SG SG-411243 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-070 SG SG-411244 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-071 SG SG-411245 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-072 SG SG-411246 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-078 RC PM:9800051 Valve N2RCPSV3450 Crosby N60491 667 Replaced valve 01/08/03 2/152216 0006 w/Crosby s/n: N60491 00-0008 1

02-02-079 RC PM:9800051 Valve N2RCPSV3451 Crosby N60491 621 Replaced valve 12/4/02 3/152217 0002 w/Crosby s/n: N60491 00-0009 1

02-02-080 RC PM:9800051 Valve N2RCPSV3452 Crosby N60491 620 Replaced valve 12/19/02 5/152218 0001 w/Crosby s/n: N60491 00-0005 1

02-02-090 RC RC-417273 RCP 2A 1R132NPP201A Westinghouse 1599 46 Replaced #2 Cartridge 12/16/02 Seal Housing 1

02-02-102 SG SG-411446 SG 1R122NSG201A Westinghouse 1FM2 78 Drill & Tap Covers 12/18/02 1

02-02-104 SG SG-411447 SG 1R122NSG201B Westinghouse 2FM2 79 Drill & Tap Covers 12/18/02 1

02-02-105 SG SG-411448 SG 1R122NSG201C Westinghouse 3FM2 80 Drill & Tap Covers 12/18/02 1

02-02-106 SG SG-411449 SG 1 R122NSG201D Westinghouse 4FM2 81 Drill & Tap Covers 12/18/02

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-109 RC RC-415162 Valve 1R142XRC0085 Westinghouse 04000GH880 W14 Replaced valve bonnet 12/18/02 000D005W7 659 50022 1

02-02-118 CV CV-422725 Valve 1R172XCV0005 Westinghouse 04001CS880 W14 Repaired weld for 12/19/02 000D005W7 890 valve seal cap 50018 1

02-02-127 SG SG-370710 SG Secondary 1R122NSG201D Westinghouse 4FM2 81 Replace handhole 01/29/03 Handhole cover 1

02-02-128 RC RC-410939 CRDM Pene #4 1R152NRD201A Westinghouse 48-W20 Seal weld build up.

1/8/2003 (K-8) 5055D47G01 506 M403 1

02-02-129 RC RC-410939 CRDM Pene #7 1R152NRD201A Westinghouse 56-W20 Replaced CRDM 1/8/2003 (K-10) 5055D47G01 514 housing. Seal weld M403 build up.

1 02-02-130 RC RC-410939 CRDM Pene 1R152NRD201A Westinghouse 40-W20 Seal weld build up.

1/8/2003

  1. 20 (L-5) 5055D47G01 498 M403 1

02-02-131 RC RC-414785 Valve 1 R142XRC0057A Kerotest CAB1 3-2 N/A Replaced valve 12/19/02 w/Kerotest s/n:

CAB20-20 1

02-02-137 RC RC-419141 Spring Can RC-2123-SH0002 NPSI RC-2123-N/A Repaired spring can.

1/21/03 SH02/0 2

02-00-005 MS PM:9700026 Valve N2MSPSV7430 Dresser BT-02188 N/A Replaced valve disc 12/16/02 6/127620 2

02-01-024 CV CV-415095 Heat Exchanger 5R172NHX202A Joseph Oats 2312-1B 987 Replaced channel 10/08/02 head studs and nuts 2

02-01-040 RH RH-410918 Pump 2R162NPA201A Pacific Pump 51734 363 Replaced pump oil 9/17/02 cooler cap screws 2

02-01-041 RH RH-410919 Pump 2R162NPA201B Pacific Pump 51735 364 Replaced pump cap 9/24/02 screws 2

02-02-028 CV PM:0100065 Valve A2CVFCV0205 Copes-Vulcan 7620-95400-1675 Replace valve plug 2/19/03 1

4/232479 1

1 1

9-2 1

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-031 SG SG-411234 SG 1R122NSG201A Westinghouse 1FM2 78 Install Swage reducer 12/19/02 2

02-02-032 SG SG-411235 SG 1R122NSG201B Westinghouse 2FM2 79 Install Swage reducer 12/19/02 2

02-02-033 SG SG-411236 SG 1R122NSG201C Westinghouse 3FM2 80 Install Swage reducer 12/19/02 2

02-02-034 SG SG-411237 SG 1R122NSG201D Westinghouse 4FM2 81 Install Swage reducer 12/19/02 2

02-02-047 FW FW-411267 Pipe Spools FW-2012-Ebasco/Bechtel 38253/38295 N/A Replaced piping 12/9/02 H,J,JA,JB,JC,JD 2

02-02-048 FW FW-411270 Pipe Spools FW-2014-Ebasco/Bechtel 38296 N/A Replaced piping 12/12/02 J,JA,JB,JC 2

02-02-049 FW FW-411273 Pipe Spools FW-2016 L, Ebasco/Bechtel 24355 N/A Replaced piping 12/11/02 LA,LBLC,LD, LE 2

02-02-050 FW FW-411276 Pipe Spools FW-2018-Ebasco/Bechtel 38297 N/A Replaced piping 12/11/02 J,JAJB,JC,JD 2

02-02-051 CV CV-411296 Pipe Spools CV-2002-C Ebasco/Bechtel 27147 N/A Replaced piping 12/19/02 2

02-02-052 CV CV-411296 Pipe Spools CV-2142-A-A3, Ebasco/Bechtel N/A N/A Replaced piping 12/19/02 B-A3 2

02-02-057 AF AF-411280 Pipe Spools AF-2008-H,G,FA, Ebasco/Bechtel 39257/39256/

N/A Replaced piping 12/12/02 FB,HA,HB, AF-37354 2062-B,BA 2

02-02-058 AF AF-411282 Pipe Spools AF-201 0-K,KA, Ebasco/Bechtel 37366 N/A Replaced piping 12/19/02 KB 2

02-02-059 AF AF-411285 Pipe Spools AF-2012-K,KA, Ebasco/Bechtel 37352 N/A Replaced piping 12/18/02 KB 2

02-02-060 AF AF-411288 Pipe Spools AF-2006-Ebasco/Bechtel 39253/39254/

N/A Replaced piping 12/11/02 N,HA,HB,HC, AF-37296 2061 -A,AA 2

02-02-061 AF AF-411283 Pipe Support AF201OHL5012 NPSI N/A N/A Replaced or modified 12/9/02 dead weight supports 2

02-02-062 AF AF-411284 Pipe Support AF2063HL5005 NPSI N/A N/A Replaced or modified 12/9/02 seismic restraints 2

02-02-063 AF AF-411287 Pipe Support AF2012HL5018 NPSI 3006-275F-N/A Remove and reweld 12/4/02 002-55 rear bracket

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-073 MS PM:01 00762 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Replaced poppet/Pilot 1/24/03

/223792 poppet 2

02-02-074 MS MS-411259 Pipe Spools MS-2001-GA2 Ebasco/Bechtel 38914/38915 N/A Removed/reinstalled 12/12/02 piping 2

02-02-075 MS MS-411261 Pipe Spools MS-2002-GA2 Ebasco/Bechtel 38863/38864 N/A Removed/reinstalled 12/17/02 piping 2

02-02-076 MS MS-411263 Pipe Spools MS-2003-GA2 Ebasco/Bechtel 38824/38825 N/A Removed/reinstalled 12/11/02 piping 2

02-02-077 MS MS-411265 Pipe Spools MS-2004-GA2 Ebasco/Bechtel 38907/38908 N/A Removed/reinstalled 12/16/02 piping 2

02-02-082 FW FW-411268 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5008, dead weight supports HL5014,HL5004 2

02-02-083 FW FW-411269 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/5/02 Supports

HL5012, seismic restraints HL5013,HL5015, HL5016 2

02-02-084 FW FW-411271 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

SHOO01, dead weight supports HL5006,HL5015 2

02-02-085 FW FW-411272 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5013, HL5014 seismic restraints 2

02-02-086 FW FW-411274 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5011, HL5017 dead weight supports 2

02-02-087 FW FW-411279 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports SHOO01 seismic restraints 2

02-02-088 FW FW-411277 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/19/02 Supports HL5014 dead weight supports 2

02-02-089 FW FW-411278 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5004, seismic restraints HL5016,SS0006 2

02-02-094 SB SB-411309 Pipe Spools SB-21 01, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2103 piping

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-095 SB SB-411311 Pipe Spools SB-2201, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2203 piping 2

02-02-096 SB SB-411313 Pipe Spools SB-2301, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2303 piping 2

02-02-097 SB SB-411315 Pipe Spools SB-2401, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2403 piping 2

02-02-098 SB SB-411444 Pipe Support SB2401HL5016U Ebasco 460 N/A Welded paddle to 1/6/03 flange 2

02-02-101 FW FW-422891 Valve A2FWFV7143 WKM 536744 2051 Installed Sealant 11/27/02 Injection Fitting 2

02-02-115 CV CV-397589 Snubber CV2088HL5002 Anchor Darling 755 N/A Replaced snubber 11/4/02 2

02-02-119 CV CV-413596 Valve 2R172TCV0191A Kerotest CAB1322 N/A Drilled out disc pin 11/27/02

_hole 2

02-02-120 CV CV-413596 Valve 2R172TCV0191 B Kerotest YG54 N/A Drilled out disc pin 11/27/02 hole 2

02-02-121 MS MS-426236 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Repaired indication on 12/19/02 valve sealing surface.

2 02-02-122 CV CV-416537 Valve C2CVHCV0218 Copes Vulcan 7620-95400-1047 Replaced valve plug 1/6/03 102 2

02-02-124 SB SB-411445 Snubber SB2401HL5016L Anchor Darling 316 N/A Replaced snubber 11/27/02 w/Anchor Darling s/n:

511 2

02-02-125 CV PM:9000070 Valve N2CVPSV3100 Crosby N662520000 1059 Replaced valve w/

2/17/03 5/198066 03 Crosby s/n N66252000004 2

02-02-134 SI SI-414196 Piping Spacer SI-2201-N-1 Ebasco N/A N/A Machined spacer 11/27/02 surface, cut off and rewelded handle 2

02-02-135 CV CV-396831 Valve 2R172XCV0026 Westinghouse 04001CS880 W14 Replaced valve 12/19/02 000D005W7 944 w/Westinghouse s/n:

50024 04001 CS880000D000 I_

I W750007

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-139 FW FW-423219 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-02-140 FW FW-427631 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-97-049 MS PM:9700025 Valve N2MSPSV741 0 Dresser BT-02186 N/A Replaced valve disc 12/16/02 6/118592 2

02-97-053 MS PM:9700026 Valve N2MSPSV741OD Dresser BT-02202 N/A Replaced valve disc 12/16/02 0/118596 2

02-97-055 MS PM:9700026 Valve N2MSPSV7420A Dresser BT-02191 N/A Replaced valve disc 12/16/02 2/118598 2

02-97-058 MS PM:9700026 Valve N2MSPSV7420D Dresser BT-02203 N/A Replaced valve disc 12/18/02 5/118601 2

02-97-061 MS PM:9700026 Valve N2MSPSV7430C Dresser BT-02200 N/A Replaced valve disc 12/16/02 9/127623

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR SYSTEM PRESSURE TESTS (CLASS 1 AND 2)

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P. O. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19,1989 Prepared by:

Reviewed by:

J.E. St uher Eng eer M. S~ash,#

~prising Engineer Z/

SCOPE 2RE09 SYSTEM PRESSURE TESTS The examinations summarized in this report were performed in accordance with the 1989 Edition with no Addenda of the ASME Code,Section XI that is applicable to the South Texas Project, Unit 2. This report covers selected ASME Code Class 1 and 2 Systems/Components.

Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in IWB-2412 and IWC-2412 for ASME Code Class 1 and 2 Systems/Components.

All ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1, Examination Category B-P, which established the examination frequency at each refueling outage.

The ASME Code Class 2 Systems/Components were selected on a prorated basis. This prorated selection process will continue until all ASME Code Class 2 Systems/Components are examined in accordance with Table IWC-2500-1, Examination Category C-H. The examination category for ASME Code Class 2 Systems/Components establishes the examination frequency at each inspection period.

Page 1 of 3 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483 Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A Commercial Service Date 06/19/89

6. National Board Number for Unit N/A Components Inspected ASME CODE CLASS 1 PIPING AND COMPONENTS Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. X 11 in., (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 41L.-z/q-o3
1.
2.
3.
5.

7.

Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province Board No.

Serial No.

No.

REACTOR VESSEL COMBUSTION ENGR/

12173 N/A 22391 1R102NRV201A WESTINGHOUSE (M)

STM. GENERATOR 2A WESTINGHOUSE (M) 2151 N/A 29 1R122NSG201A STM. GENERATOR 2B WESTINGHOUSE (M) 2152 N/A 30 1R122NSG201B_

STM. GENERATOR 2C WESTINGHOUSE (M) 2153 N/A 31 1R122NSG201C STM. GENERATOR 2D WESTINGHOUSE (M) 2154 N/A 32 1R122NSG201D PRESSURIZER 2A WESTINGHOUSE (M) 2161 N/A N/A 1R112NPZ201A RC PUMP 2A WESTINGHOUSE (M) 1-115E580G02 N/A 46 1R132NPP201A RC PUMP 2B WESTINGHOUSE (M) 2-115E580G02 N/A 47 1R132NPP201B RC PUMP 2C WESTINGHOUSE (M) 3-115E580G02 N/A 48 1R132NPP201C RC PUMP 2D WESTINGHOUSE (M) 4-115E580G02 N/A 49 1 R132NPP201D CLASS 1 PIPING EBASCO (I)

VARIOUS N/A N/A CLASS 1 VALVES VARIOUS VARIOUS N/A N/A

Page 2 of 3 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section Xl 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 3 of 3.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 3 of 3.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date 20 *Signed STP Nuclear Operating CompanV. By

ý, 4,'14-j Owner 0M&/S. tashley Test Engineering Supervisor Date 20 03 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston, Rhode Island. have inspected the components described in this Owner's Report during the period 04103/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage o a ss of any kind arising from or connected with this inspection.

Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State, Province, and Endorsements

Page 3 of 3 SUPPLEMENTAL PAGE FOR ASME CODE CLASS 1 PIPING AND COMPONENTS

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483

2.

Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
13.

ABSTRACT OF EXAMINATIONS AND TESTS A System Leakage Test as prescribed in IWA-521 1(a) for all ASME Code Class 1 Pressure Retaining Components was conducted in accordance with Table IWB-2500-1, Examination Category B-P, Item Nos. B135.10, B15.20, B15.30, B15.40, B15.50, B15.60, and B15.70.

The Pressure Test and VT-2 visual examinations were conducted in accordance with Plant Surveillance Pressure Test Procedure, OPSP15-RC-0001, Reactor Coolant System Leakage Pressure Test, at the conclusion of the ninth refueling outage. ASME Code Class 1 piping and valves are specifically identified in the above referenced procedure.

15.

ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during the Pressure Test found minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined to be acceptable for continued operation. Appropriate corrective action was initiated to correct these leaks.

4.j2-2,-i,7-oa

Page 1 of 5 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner STP Nuclear Operating Company, P. 0 Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

2.

Plant South Texas Proiect Electric Generating Station P.O Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
7.

Components Inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

RCFC COILS 21A, 22A, American Air Filter Various N/A Various 21 B, 22B, 21 C, and 22C RHR 2A Ht. Exch.

Joseph Oats 2312-4D N/A 993 2R162NHX201A RHR Pump 2A Pacific Pumps 51734 N/A 363 2R162NPA201A RHR 2B Ht. Exch.

Joseph Oats 2312-4E N/A 994 2R162NHX201B RHR Pump 2B Pacific Pumps 51734 N/A 363 2R162NPA201B RHR 2C Ht. Exch.

Joseph Oats 2312-4F N/A 995 2R162NHX201C RHR Pump 2C Pacific Pumps 51736 N/A 365 2R162NPA201C CVCS Seal Water Lamco 833 N/A 256 Return Ht. Exch.

4R172NHX204A CVCS Letdown Ht.

Joseph Oats 2312-1B N/A 987 Exch.

5R172NHX202A CVCS Excess Letdown Joseph Oats 2312-3B N/A 989 Ht. Exch.

5R172NHX203A Volume Control Tank 2A Reco Industries N-2287.10 N/A 76881 2R172NTS201A Suction Pulsation Johnson Controls Inc M-0439 N/A 177 Dampener Htr 2R172NPD201A CVCS Seal Injection Ptrinity 35364 N/A 19022 Filter 2A 2R172NFR202A CVCS Seal Injection Ptrinity 35365 N/A 19023 Filter 2B 2R172NFR202B 4,:0-1,7-03

Page 2 of 5 Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Centrifugal Charging Dresser Industries, Inc 51901 N/A 429 Pump2A 2R172NPA201A Centrifugal Charging Dresser Industries, Inc 51902 N/A 430 Pump 2B 2R172NPA201B Positive Displacement Union Pump Company N753718A602 N/A N/A Pump 2R172NPA202A Pulsation Dampener Johnson Controls Inc M-0440 N/A 178 2R172NPD202A CVCS Seal Injection Ptrinity 35959 N/A 19482 Filter 2B 2R172NFR201B CVCS RC Filter 2A Ptrinity 35958 N/A 19481 2R172NFR201A CVCS Seal Water Ptrinity 35960 N/A 19483 Return Filter 2R172NFR203A Seal Water Hx Lamco 833 N/A 256 4R172NHX204A Letdown Hx 2A Joseph Oat Corp 2312-1 B N/A 987 5R172NHX202A Regen Letdn Hx Joseph Oat Corp J-2312-2B N/A 985 5R192NHX203A Regen Hx 2A Joseph Oat Corp 2380-1 B N/A 2052 2R172NHX201A CVCS Excess Letdown Joseph Oat Corp 2312-3B N/A 989 Ht Exch 2A 5R172NHX203A RHR HX 2A Joseph Oat Corp 2312-4D N/A 993 2R162NHX201A RHR HX 2B Joseph Oat Corp 2312-4E N/A 994 2R162NHX201B RHR HX 2C Joseph Oat Corp 2312-4F N/A 995 2R1 62NHX201 C RHR PUMP 2A Pacific Pump 51734 N/A 363 2R162NPA201A RHR PUMP 2B Pacific Pump 51735 N/A 364 2R1 62NPA201 B RHR PUMP 2C Pacific Pump 51736 N/A 365 2R162NPA201 C 4--/-'

Page 3 of 5 Supplemental sneets in Torm of lists, sKetcnes, or drawings may De usea, proviaed t1) size is s 1i2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

At-z-9--;

Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

STM. GENERATOR 2A WESTINGHOUSE (M) 2151 N/A 29 1R122NSG201A STM. GENERATOR 2B WESTINGHOUSE (M) 2152 N/A 30 1R122NSG201B STM. GENERATOR 2C WESTINGHOUSE (M) 2153 N/A 31 1R122NSG201C STM. GENERATOR 2D WESTINGHOUSE (M) 2154 N/A 32 1R122NSG201D ASSOC. CLASS 2 EBASCO (I)

VARIOUS N/A N/A PIPING ASSOC. CLASS 2 VARIOUS VARIOUS N/A N/A VALVES Note:

Page 4 of 5 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section XI 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 5 of 5.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 5 of 5.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date

'/-',/

200 Signed STP Nuclear Operating Company. By Owner MA. lashley Test Engineering Supervisor Date

,/'-

200?

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston, Rhode Island, have inspected the components described in this Owner's Report during the period 04/03/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a os of any kind arising from or connected with this inspection.

n

__Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State, Province, and Endorsements

Page 5 of 5 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS

1. Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)
2.

Plant South Texas Proiect Electric Generating Station, P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
13. ABSTRACT OF EXAMINATIONS System Functional and Inservice Pressure Tests as prescribed by IWA-5211 (b) and (c), respectively, were conducted on selected ASME Code Class 2 pressure retaining components in accordance with Table IWC-2500-1, Examination Category C-H, Item Nos. C7.1 0, C7.30, C7.50 and C7.70.

The Pressure Tests and VT-2 visual examinations were conducted during the first period of examination of the second interval in accordance with the following Plant Surveillance Pressure Test Procedures:

OPSP15-CC-0001 Component Cooling Water System Inservice Pressure Test 0PSP15-CV-0001 Chemical Volume Control System Inservice Pressure Test OPSP1 5-CV-0007 Chemical Volume Control System Inservice Pressure Test OPSP1 5-FC-0001 Spent Fuel Pool Cooling & Cleaning System Inservice Pressure Test OPSP15-RH-0001 Residual Heat Removal System Inservice Pressure Test ASME Code Class 2 piping and valves are specifically identified in the above referenced procedures.

15. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined acceptable for continued system operation. Appropriate corrective action was initiated to correct these leaks.

-/9-v

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P.O. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19, 1989 Prepared by:

S(J.E. Stauber, Engineer Reviewed by:

a, --

"YM.S.fashley, Supervising Engineer

SCOPE 2RE09 REPAIRS AND REPLACEMENTS The inspections and records summarized in this report were performed in accordance with Section XI of the ASME Code, 1989 Edition with no Addenda, which is applicable to the South Texas Project, Unit 2.

This report covers ASME Code Class 1 and 2 pressure-retaining components and their supports where repair or replacement was performed between the end of the eighth refueling outage and the end of the ninth refueling outage just completed. This report is submitted in accordance with paragraph IWA-6230 of Section Xl for ASME Code Class 1 and 2 pressure retaining components and their supports.

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-004 SG SG-370700 SG Primary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-005 SG SG-370703 SG Primary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-006 SG SG-370706 SG Primary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03 Manways washers 1

02-02-007 SG SG-370709 SG Primary 1R122NSG201D Westinghouse 4FM2 81 Installed studs, nuts &

1/27/03 Manways washers 1

02-02-008 SG SG-370701 SG Secondary 1R122NSG201A Westinghouse 1FM2 78 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-009 SG SG-370704 SG Secondary 1R122NSG201B Westinghouse 2FM2 79 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-010 SG SG-370707 SG Secondary 1R122NSG201C Westinghouse 3FM2 80 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-011 SG SG-370710 SG Secondary 1 R122NSG201 D Westinghouse 4FM2 81 Installed studs, nuts &

1/29/03

Manways, washers Inspection Ports

& Handhole 1

02-02-022 SG SG-411247 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-023 SG SG-411248 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-024 SG SG-411249 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1_ _

1_

1_

1_ Lateral Supports I

I I

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-025 SG SG-411250 SG Lower N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-026 SG SG-411230 SG 1R122NSG201A Westinghouse 1FM2 78 Performed RCS 12/18/02 Nozzle Preps 1

02-02-027 SG SG-411231 SG 1R122NSG201B Westinghouse 2FM2 79 Performed RCS 12/18/02 Nozzle Preps 1

02-02-029 SG SG-411232 SG 1R122NSG201C Westinghouse 3FM2 80 Performed RCS 12/18/02 Nozzle Preps 1

02-02-030 SG SG-411233 SG 1R122NSG201D Westinghouse 4FM2 81 Performed RCS 12/18/02 Nozzle Preps 1

02-02-039 SG SG-411251 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-040 SG SG-411252 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/4/02 1

02-02-041 SG SG-411253 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-042 SG SG-411254 RCP Tie Rods N/A Westinghouse N/A N/A Install bolted shims 12/2/02 1

02-02-043 RC RC-411238 RCS Piping N/A Southwest Fab 19003/19004 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-044 RC RC-411239 RCS Piping N/A Southwest Fab 19007/19008 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-045 RC RC-411240 RCS Piping N/A Southwest Fab 19011/19012 N/A Removed/reinstalled 12/12/02 RCS Piping 1

02-02-046 RC RC-411241 RCS Piping N/A Southwest Fab 19015/19016 N/A Removed/reinstalled 12/11/02 RCS Piping 1

02-02-053 SG SG-411317 Steam 1R122NSG201A Westinghouse 2151 29 Removed Old SG 12/4/02 Generator 1

02-02-054 SG SG-411318 Steam 1R122NSG201B Westinghouse 2152 30 Removed Old SG 12/4/02 Generator 1

02-02-055 SG SG-411319 Steam 1R122NSG201C Westinghouse 2153 31 Removed Old SG 12/4/02 Generator 1

02-02-056 SG SG-411320 Steam 1R122NSG201D Westinghouse 2154 32 Removed Old SG 12/4/02 Generator

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-064 SG SG-411322 Steam 1 R122NSG201A Westinghouse 1FM2 78 Installed New SG 12/18/02 Generator 1

02-02-065 SG SG-411323 Steam 1 R1 22NSG201 B Westinghouse 2FM2 79 Installed New SG 12/18/02 Generator 1

02-02-066 SG SG-411324 Steam 1R122NSG201C Westinghouse 3FM2 80 Installed New SG 12/18/02 Generator 1

02-02-067 SG SG-411325 Steam 1R122NSG201D Westinghouse 4FM2 81 Installed New SG 12/18/02 Generator 1

02-02-069 SG SG-411243 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-070 SG SG-411244 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-071 SG SG-411245 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/2/02 Lateral Supports 1

02-02-072 SG SG-411246 SG Upper N/A Westinghouse N/A N/A Install bolted shims 12/3/02 Lateral Supports 1

02-02-078 RC PM:9800051 Valve N2RCPSV3450 Crosby N60491 667 Replaced valve 01/08/03 2/152216 0006 w/Crosby s/n: N60491 1

00-0008 1

02-02-079 RC PM:9800051 Valve N2RCPSV3451 Crosby N60491 621 Replaced valve 12/4/02 3/152217 0002 w/Crosby s/n: N60491 00-0009 1

02-02-080 RC PM:9800051 Valve N2RCPSV3452 Crosby N60491 620 Replaced valve 12/19/02 5/152218 0001 w/Crosby s/n: N60491 00-0005 1

02-02-090 RC RC-417273 RCP 2A 1R132NPP201A Westinghouse 1599 46 Replaced #2 Cartridge 12/16/02 Seal Housing 1

02-02-102 SG SG-411446 SG 1 R1 22NSG201 A Westinghouse 1FM2 78 Drill & Tap Covers 12/18/02 1

02-02-104 SG SG-411447 SG 1 R122NSG201B Westinghouse 2FM2 79 Drill & Tap Covers 12/18/02 1

02-02-105 SG SG-411448 SG 1R122NSG201C Westinghouse 3FM2 80 Drill & Tap Covers 12/18/02 02-02-106 SG SG-411449 SG 1R122NSG201D Westinghouse 4FM2 81 Drill & Tap Covers 12/18/02

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 1 02-02-109 RC RC-415162 Valve 1R142XRC0085 Westinghouse 04000GH880 W14 Replaced valve bonnet 12/18/02 000D005W7 659 50022 1

02-02-118 CV CV-422725 Valve 1R172XCV0005 Westinghouse 04001CS880 W14 Repaired weld for 12/19/02 000D005W7 890 valve seal cap 50018 1

02-02-127 SG SG-370710 SG Secondary 1R122NSG201D Westinghouse 4FM2 81 Replace handhole 01/29/03 Handhole cover 1

02-02-128 RC RC-410939 CRDM Pene #4 1R152NRD201A Westinghouse 48-W20 Seal weld build up.

1/8/2003 (K-8) 5055D47G01 506 M403 1

02-02-129 RC RC-410939 CRDM Pene #7 1R152NRD201A Westinghouse 56-W20 Replaced CRDM 1/8/2003 (K-i10) 5055D47G01 514 housing. Seal weld M403 build up.

1 02-02-130 RC RC-410939 CRDM Pene 1R152NRD201A Westinghouse 40-W20 Seal weld build up.

1/8/2003

  1. 20 (L-5) 5055D47G01 498 M403 1

02-02-131 RC RC-414785 Valve 1 R 142XRC0057A Kerotest CAB1 3-2 N/A Replaced valve 12/19/02 w/Kerotest s/n:

CAB20-20 1

02-02-137 RC RC-419141 Spring Can RC-2123-SH0002 NPSI RC-2123-N/A Repaired spring can.

1/21/03 SH02/0 2

02-00-005 MS PM:9700026 Valve N2MSPSV7430 Dresser BT-02188 N/A Replaced valve disc 12/16/02 6/127620 2

02-01-024 CV CV-415095 Heat Exchanger 5R172NHX202A Joseph Oats 2312-1B 987 Replaced channel 10/08/02 head studs and nuts 2

02-01-040 RH RH-410918 Pump 2R162NPA201A Pacific Pump 51734 363 Replaced pump oil 9/17/02 cooler cap screws 2

02-01-041 RH RH-410919 Pump 2R162NPA201B Pacific Pump 51735 364 Replaced pump cap 9/24/02 screws 2

02-02-028 CV PM:01 00065 Valve A2CVFCV0205 Copes-Vulcan 7620-95400-1675 Replace valve plug 2/19/03 4/232479 1

1 9-2 1

1 1

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-031 SG SG-411234 SG 1R122NSG201A Westinghouse 1FM2 78 Install Swage reducer 12/19/02 2

02-02-032 SG SG-411235 SG 1R122NSG201B Westinghouse 2FM2 79 Install Swage reducer 12/19/02 2

02-02-033 SG SG-411236 SG 1R122NSG201C Westinghouse 3FM2 80 Install Swage reducer 12/19/02 2

02-02-034 SG SG-411237 SG 1R122NSG201D Westinghouse 4FM2 81 Install Swage reducer 12/19/02 2

02-02-047 FW FW-411267 Pipe Spools FW-2012-Ebasco/Bechtel 38253/38295 N/A Replaced piping 12/9/02 H,J,JA,JB,JC,JD 2

02-02-048 FW FW-411270 Pipe Spools FW-2014-Ebasco/Bechtel 38296 N/A Replaced piping 12/12/02 J,JA,JB,JC 2

02-02-049 FW FW-411273 Pipe Spools FW-2016 L, Ebasco/Bechtel 24355 N/A Replaced piping 12/11/02 LA,LBLC,LD, LE 2

02-02-050 FW FW-411276 Pipe Spools FW-2018-Ebasco/Bechtel 38297 N/A Replaced piping 12/11/02 J,JA,JB,JC,JD 2

02-02-051 CV CV-411296 Pipe Spools CV-2002-C Ebasco/Bechtel 27147 N/A Replaced piping 12/19/02 2

02-02-052 CV CV-411296 Pipe Spools CV-2142-A-A3, Ebasco/Bechtel N/A N/A Replaced piping 12/19/02 B-A3 2

02-02-057 AF AF-411280 Pipe Spools AF-2008-H,G,FA, Ebasco/Bechtel 39257/39256/

N/A Replaced piping 12/12/02 FB,HA,HB, AF-37354 2062-B,BA 2

02-02-058 AF AF-411282 Pipe Spools AF-2010-K,KA, Ebasco/Bechtel 37366 N/A Replaced piping 12/19/02 KB 2

02-02-059 AF AF-411285 Pipe Spools AF-2012-K,KA, Ebasco/Bechtel 37352 N/A Replaced piping 12/18/02 KB 2

02-02-060 AF AF-411288 Pipe Spools AF-2006-Ebasco/Bechtel 39253/39254/

N/A Replaced piping 12/11/02 N,HA,HBHC, AF-37296 2061 -A,AA 2

02-02-061 AF AF-411283 Pipe Support AF201OHL5012 NPSI N/A N/A Replaced or modified 12/9/02 dead weight supports 2

02-02-062 AF AF-411284 Pipe Support AF2063HL5005 NPSI N/A N/A Replaced or modified 12/9/02 seismic restraints 2

02-02-063 AF AF-411287 Pipe Support AF2012HL5018 NPSI 3006-275F-N/A Remove and reweld 12/4/02 1

1 1

1 111 002-55 rear bracket I

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-073 MS PM:01 00762 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Replaced poppet/Pilot 1/24/03

/223792 poppet 2

02-02-074 MS MS-411259 Pipe Spools MS-2001 -GA2 Ebasco/Bechtel 38914/38915 N/A Removed/reinstalled 12/12/02 piping 2

02-02-075 MS MS-411261 Pipe Spools MS-2002-GA2 Ebasco/Bechtel 38863/38864 N/A Removed/reinstalled 12/17/02 piping 2

02-02-076 MS MS-411263 Pipe Spools MS-2003-GA2 Ebasco/Bechtel 38824/38825 N/A Removed/reinstalled 12/11/02 piping 2

02-02-077 MS MS-411265 Pipe Spools MS-2004-GA2 Ebasco/Bechtel 38907/38908 N/A Removed/reinstalled 12/16/02 piping 2

02-02-082 FW FW-411268 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5008, dead weight supports HL5014,HL5004 2

02-02-083 FW FW-411269 Pipe FW-2012-Bechtel N/A N/A Replaced or modified 12/5/02 Supports

HL5012, seismic restraints HL5013,HL5015, HL5016 2

02-02-084 FW FW-411271 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

SHOO01, dead weight supports HL5006,HL5015 2

02-02-085 FW FW-411272 Pipe FW-2014-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5013, HL5014 seismic restraints 2

02-02-086 FW FW-411274 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports HL5011, HL5017 dead weight supports 2

02-02-087 FW FW-411279 Pipe FW-2016-Bechtel N/A N/A Replaced or modified 12/9/02 Supports SHOO01 seismic restraints 2

02-02-088 FW FW-411277 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/19/02 Supports HL5014 dead weight supports 2

02-02-089 FW FW-411278 Pipe FW-2018-Bechtel N/A N/A Replaced or modified 12/9/02 Supports

HL5004, seismic restraints HL5016,SS0006 2

02-02-094 SB SB-411309 Pipe Spools SB-2101, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2103 piping

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-095 SB SB-411311 Pipe Spools SB-2201, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2203 piping 2

02-02-096 SB SB-411313 Pipe Spools SB-2301, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2303 piping 2

02-02-097 SB SB-411315 Pipe Spools SB-2401, Ebasco N/A N/A Removed/reinstalled 12/18/02 SB2403 piping 2

02-02-098 SB SB-411444 Pipe Support SB2401HL5016U Ebasco 460 N/A Welded paddle to 1/6/03 flange 2

02-02-101 FW FW-422891 Valve A2FWFV7143 WKM 536744 2051 Installed Sealant 11/27/02 Injection Fitting 2

02-02-115 CV CV-397589 Snubber CV2088HL5002 Anchor Darling 755 N/A Replaced snubber 11/4/02 2

02-02-119 CV CV-413596 Valve 2R172TCV0191A Kerotest CAB1322 N/A Drilled out disc pin 11/27/02 hole 2

02-02-120 CV CV-413596 Valve 2R172TCV0191B Kerotest YG54 N/A Drilled out disc pin 11/27/02 1_

hole 2

02-02-121 MS MS-426236 Valve A2MSFSV7424 Atwood Morrill 5-13839 N/A Repaired indication on 12/19/02 valve sealing surface.

2 02-02-122 CV CV-416537 Valve C2CVHCV0218 Copes Vulcan 7620-95400-1047 Replaced valve plug 1/6/03 102 2

02-02-124 SB SB-411445 Snubber SB2401HL5016L Anchor Darling 316 N/A Replaced snubber 11/27/02 w/Anchor Darling s/n:

511 2

02-02-125 CV PM:9000070 Valve N2CVPSV31 00 Crosby N662520000 1059 Replaced valve w/

2/17/03 5/198066 03 Crosby s/n N66252000004 2

02-02-134 SI SI-414196 Piping Spacer SI-2201-N-1 Ebasco N/A N/A Machined spacer 11/27/02 surface, cut off and rewelded handle 2

02-02-135 CV CV-396831 Valve 2R172XCV0026 Westinghouse 04001CS880 W14 Replaced valve 12/19/02 000D005W7 944 w/Westinghouse s/n:

50024 04001 CS880000DOOO I_

I_

_W750007 I

SOUTH TEXAS PROJECT UNIT 2 ASME SECTION XI 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 AND 2)

CLASS R or R SYSTEM WORK COMPONENT COMPONENT MFG.

SERIAL NO.

NBN DESCRIPTION OF COMP.

NO.

DOC.

DESCRIPTION IDENTITY WORK DATE (TAG TPNS) 2 02-02-139 FW FW-423219 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-02-140 FW FW-427631 Tubing N/A N/A N/A N/A Repaired SG tubing 12/19/02 leak by seal welding.

2 02-97-049 MS PM:9700025 Valve N2MSPSV7410 Dresser BT-02186 N/A Replaced valve disc 12/16/02 6/118592 2

02-97-053 MS PM:9700026 Valve N2MSPSV7410D Dresser BT-02202 N/A Replaced valve disc 12/16/02 0/118596 2

02-97-055 MS PM:9700026 Valve N2MSPSV7420A Dresser BT-02191 N/A Replaced valve disc 12/16/02 2/118598 2

02-97-058 MS PM:9700026 Valve N2MSPSV7420D Dresser BT-02203 N/A Replaced valve disc 12/18/02 5/118601 1

1 1

1 1

2 02-97-061 MS PM:9700026 Valve N2MSPSV7430C Dresser BT-02200 N/A Replaced valve disc 12/16/02 9/127623 1

COVER SHEET 2RE09 INSERVICE INSPECTION

SUMMARY

REPORT FOR SYSTEM PRESSURE TESTS (CLASS 1 AND 2)

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 2 P. 0. BOX 289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-499 OPERATING LICENSE NO: NPF-80 COMMERCIAL OPERATION DATE: JUNE 19,1989 Prepared by:

q Prepredby:J. E. Stdueer, Engineer Reviewed by:

j A-

/tf M. SLashi

, S pervising Engineer

SCOPE 2RE09 SYSTEM PRESSURE TESTS The examinations summarized in this report were performed in accordance with the 1989 Edition with no Addenda of the ASME Code, Section Xl that is applicable to the South Texas Project, Unit 2. This report covers selected ASME Code Class 1 and 2 Systems/Components.

Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in IWB-2412 and IWC-2412 for ASME Code Class 1 and 2 Systems/Components.

All ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1, Examination Category B-P, which established the examination frequency at each refueling outage.

The ASME Code Class 2 Systems/Components were selected on a prorated basis. This prorated selection process will continue until all ASME Code Class 2 Systems/Components are examined in accordance with Table IWC-2500-1, Examination Category C-H. The examination category for ASME Code Class 2 Systems/Components establishes the examination frequency at each inspection period.

Page 1 of 3 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner STP Nuclear Operatinq Company, P. 0. Box 289, Wadsworth, TX 77483 Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483 Plant Unit 2

4. Owner Certificate of Authorization (if required).

N/A Commercial Service Date 06/19/89

6. National Board Number for Unit N/A Components Inspected ASME CODE CLASS 1 PIPING AND COMPONENTS Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. X 11 in., (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form
1.
2.
3.
5.

7.

Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province Board No.

Serial No.

No.

REACTOR VESSEL COMBUSTION ENGR/

12173 N/A 22391 1R102NRV201A WESTINGHOUSE (M)

STM. GENERATOR 2A WESTINGHOUSE (M) 2151 N/A 29 1R122NSG201A STM. GENERATOR 2B WESTINGHOUSE (M) 2152 N/A 30 1 R122NSG201B STM. GENERATOR 2C WESTINGHOUSE (M) 2153 N/A 31 1R122NSG201C STM. GENERATOR 2D WESTINGHOUSE (M) 2154 N/A 32 1R122NSG201D PRESSURIZER 2A WESTINGHOUSE (M) 2161 N/A NIA 1R112NPZ201A RCPUMP2A WESTINGHOUSE (M) 1-115E580G02 N/A 46 1R132NPP201A RC PUMP 2B WESTINGHOUSE (M) 2-115E580G02 N/A 47 1R132NPP201B RC PUMP 2C WESTINGHOUSE (M) 3-115E580G02 N/A 48 1R132NPP201C RC PUMP 2D WESTINGHOUSE (M) 4-115E580G02 N/A 49 1 R132NPP201D CLASS 1 PIPING EBASCO (I)

VARIOUS N/A N/A CLASS 1 VALVES VARIOUS VARIOUS N/A N/A 41a -z-jq-03

Page 2 of 3 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section XI 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 3 of 3.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 3 of 3.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date

/'-/,,*4.

20.*._Signed STP Nuclear Operating Company. By

-,.-/4J Owner 1VM.S. L aashley Test Engineering Supervisor CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston, Rhode Island. have inspected the components described in this Owner's Report during the period 04/03/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage o a ss of any kind arising from or connected with this inspection.

Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State, Province, and Endorsements Date 20 0.3

Page 3 of 3 SUPPLEMENTAL PAGE FOR ASME CODE CLASS 1 PIPING AND COMPONENTS

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth. TX 77483

2.

Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
13.

ABSTRACT OF EXAMINATIONS AND TESTS A System Leakage Test as prescribed in IWA-5211(a) for all ASME Code Class 1 Pressure Retaining Components was conducted in accordance with Table IWB-2500-1, Examination Category B-P, Item Nos. B1 5.10, B15.20, B15.30, B15.40, B15.50, B15.60, and B15.70.

The Pressure Test and VT-2 visual examinations were conducted in accordance with Plant Surveillance Pressure Test Procedure, OPSP15-RC-0001, Reactor Coolant System Leakage Pressure Test, at the conclusion of the ninth refueling outage. ASME Code Class 1 piping and valves are specifically identified in the above referenced procedure.

15.

ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during the Pressure Test found minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined to be acceptable for continued operation. Appropriate corrective action was initiated to correct these leaks.

Page 1 of 5 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)
2.

Plant South Texas Proiect Electric Generating Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
7.

Components Inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

RCFC COILS 21A, 22A, American Air Filter Various N/A Various 21 B, 22B, 21 C, and 22C RHR 2A Ht. Exch.

Joseph Oats 2312-4D N/A 993 2R162NHX201A RHR Pump 2A Pacific Pumps 51734 N/A 363 2R162NPA201A RHR 2B Ht. Exch.

Joseph Oats 2312-4E N/A 994 2R1 62NHX201 B RHR Pump 2B Pacific Pumps 51734 N/A 363 2R162NPA201B RHR 2C Ht. Exch.

Joseph Oats 2312-4F N/A 995 2R162NHX201C RHR Pump 2C Pacific Pumps 51736 N/A 365 2R162NPA201C CVCS Seal Water Lamco 833 N/A 256 Return Ht. Exch.

4R172NHX204A CVCS Letdown Ht.

Joseph Oats 2312-1 B N/A 987 Exch.

5R172NHX202A CVCS Excess Letdown Joseph Oats 2312-3B N/A 989 Ht. Exch.

5R172NHX203A Volume Control Tank 2A Reco Industries N-2287.10 N/A 76881 2R1 72NTS201A Suction Pulsation Johnson Controls Inc M-0439 N/A 177 Dampener Htr 2R172NPD201A CVCS Seal Injection Ptrinity 35364 N/A 19022 Filter 2A 2R172NFR202A CVCS Seal Injection Ptrinity 35365 N/A 19023 Filter 2B 2R172NFR202B

Page 2 of 5 Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Centrifugal Charging Dresser Industries, Inc 51901 N/A 429 Pump 2A 2RI72NPA201A Centrifugal Charging Dresser Industries, Inc 51902 N/A 430 Pump 2B 2R172NPA2011B Positive Displacement Union Pump Company N753718A602 N/A N/A Pump 2R172NPA202A Pulsation Dampener Johnson Controls Inc M-0440 N/A 178 2R172NPD202A CVCS Seal Injection Ptrinity 35959 N/A 19482 Filter 2B 2R172NFR201B CVCS RC Filter 2A Ptrinity 35958 N/A 19481 2R172NFR201A CVCS Seal Water Ptrinity 35960 N/A 19483 Return Filter 2R172NFR203A Seal Water Hx Lamco 833 N/A 256 4R1 72NHX204A Letdown Hx 2A Joseph Oat Corp 2312-1 B N/A 987 5R172NHX202A Regen Letdn Hx Joseph Oat Corp J-2312-2B N/A 985 5R192NHX203A Regen Hx 2A Joseph Oat Corp 2380-1 B N/A 2052 2R172NHX201A CVCS Excess Letdown Joseph Oat Corp 2312-3B N/A 989 Ht Exch 2A 5R172NHX203A RHR HX 2A Joseph Oat Corp 2312-4D N/A 993 2R162NHX201A RHR HX 2B Joseph Oat Corp 2312-4E N/A 994 2R1 62NHX201 B RHR HX 2C Joseph Oat Corp 2312-4F N/A 995 2R162NHX201C RHR PUMP 2A Pacific Pump 51734 N/A 363 2R162NPA201A RHR PUMP 2B Pacific Pump 51735 N/A 364 2R162NPA2011B RHR PUMP 2C Pacific Pump 51736 N/A 365 2R162NPA201C 4e-2-19-"3

Page 3 of 5 Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

STM. GENERATOR 2A WESTINGHOUSE (M) 2151 N/A 29 1R122NSG201A STM. GENERATOR 2B WESTINGHOUSE (M) 2152 N/A 30 1R122NSG201B STM. GENERATOR 2C WESTINGHOUSE (M) 2153 N/A 31 1R122NSG201C STM. GENERATOR 2D WESTINGHOUSE (M) 2154 N/A 32 1R122NSG201D ASSOC. CLASS 2 EBASCO (I)

VARIOUS N/A N/A PIPING ASSOC. CLASS 2 VARIOUS VARIOUS N/A N/A VALVES IIII_

I Note:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page 4 of 5 FORM NIS-1 (Back)

8. Examination Dates 04/03/2001 to 12/10/2002
9. Inspection Period Identification First Period (10/19/00 to 10/18/03)
10. Inspection Interval Identification Second Interval (10/19/00 to 10/18/10)
11. Applicable Edition of Section Xl 1989 Edition Addenda none
12. Date/Revision of Inspection Plan: September 2002/Revision 11
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Refer to Supplemental Sheet Page 5 of 5.
14. Abstract of Results of Examinations and Tests.

No relevant conditions affecting pressure-retaining boundaries were noted.

15. Abstract of Corrective Measures.

Refer to Supplemental Sheet Page 5 of 5.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date 11'Al4i/V 20 N Signed STP Nuclear Operating Company. By (A

e Owner M/. Lashley Test Engineering Supervisor LDate-C CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Factory Mutual Insurance Co. of Johnston, Rhode Island, have inspected the components described in this Owner's Report during the period 04/03/2001 to 12/10/2002, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a os of any kind arising from or connected with this inspection.

Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State, Province, and Endorsements

Page 5 of 5 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS

1.

Owner STP Nuclear Operating Company, P. 0. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

2.

Plant South Texas Proiect Electric Generatinq Station, P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner)

3.

Plant Unit 2

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 06/19/89

6. National Board Number for Unit N/A
13. ABSTRACT OF EXAMINATIONS System Functional and Inservice Pressure Tests as prescribed by IWA-5211 (b) and (c), respectively, were conducted on selected ASME Code Class 2 pressure retaining components in accordance with Table IWC-2500-1, Examination Category C-H, Item Nos. C7.1 0, C7.30, C7.50 and C7.70.

The Pressure Tests and VT-2 visual examinations were conducted during the first period of examination of the second interval in accordance with the following Plant Surveillance Pressure Test Procedures:

OPSP15-CC-0001 OPSP15-CV-0001 OPSP15-CV-0007 OPSP15-FC-0001 OPSP1 5-RH-0001 Component Cooling Water System Inservice Pressure Test Chemical Volume Control System Inservice Pressure Test Chemical Volume Control System Inservice Pressure Test Spent Fuel Pool Cooling & Cleaning System Inservice Pressure Test Residual Heat Removal System Inservice Pressure Test ASME Code Class 2 piping and valves are specifically identified in the above referenced procedures.

15. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined acceptable for continued system operation. Appropriate corrective action was initiated to correct these leaks.