AmerGenSM AmerGen Energy Company, LLC An Exelon/British Energy Company Oyster Creek US Route 9 South PO Box 388 10 CFR 50.55a(g)
Forked River, NJ 08731-0388 January 22, 2003 2130-03-20009 United States Nuclear Regulatory Commission Document Control Desk Washington DC 20555
Subject:
Oyster Creek Generating Station Docket 50-219 Inservice Inspection Data Reports In accordance-with 10 CFR 50.55a(g), ASME XI Section IWA-6220 1986 edition, and Section LWE 1992 edition, AmerGen Energy Company, LLC, is forwarding the requisite reports resulting from Inservice Inspection activities conducted during the recent 1R19 refueling outage the Oyster Creek Generating Station.
The Forms NIS - 1 have been separated into two attachments. Attachment I contains the results of inspection activities performed in vessel (Section ISI). Attachment II contains the results of all inspection activities performed on the containment (Section IWE). The Form NIS-2 on repairs and/or replacements has been included as Attachment I]I If you should require any further information, please contact Mr. John Rogers, of my staff, at 609.971.4893 Very truly yours, Ernest J. Harkness P.E., Vice President Oyster Creek Generating Station EJH/JJR
'\\
cc:
Administrator, Region I NRC Senior Project Manager NRC Senior Resident Inspector
Attachment I Form NIS - 1 Section ISI
NIS - 1 Report Abstract
- 13. Abstract of Examinations and Tests.
This submittal is for the ISI examinations performed during the Oyster Creek refueling outage 1R19. This is Oyster Creek's final submittal for the third inspection interval. See table 1 for details. The inspection interval ended on October 15th 2002, and was extended an additional 90 days to allow for completing Section XI examinations in refueling outage 1R19. Oyster Creek has completed the required examinations in accordance with the 1986 Edition of ASME Section XI. Ninety-eight examinations were scheduled for ASME Section XI requirements, seven examinations were scheduled for Augmented requirements and seventeen examinations were scheduled for Generic Letter 88-01 requirements. There were eight welds where Section XI credit could not be attained. The limitation was due do single side access on stainless steel welds where the rules prescribe by the Performance Demonstrative Initiative (PDI) stainless steel welds shall be examined from two directions. For the list of welds not able to meet Code coverage see table 2 included in this submittal. These welds shall be addressed in a relief request. The only ASME Code Cases applied to these examinations was N-524, "Alternative examination requirements for longitudinal welds in Class 1 and 2 piping", and N-498-1, "Alternative Rules for 10-Year Hydrostatic Pressure Testing for Class 1, 2 and 3 Systems,Section XI, Division 1."
Reactor Pressure Vessel Shroud Support An ultrasonic examination was performed on the "H-9" weld. This weld connects the shroud support (conical support) to the reactor vessel on the inner diameter. The ultrasonic examination was performed in accordance with "Reactor Pressure Vessel and Internals Examination Guidelines (BWRVIP-03)".
Automatic scans were performed form the vessel OD surface, examining the top and bottom sides of welds H-9 in three selected areas accessed through the reactor Recirculation nozzles bio-shield opens at locations NIA, NIC and N1E. The composite coverage between manual and automatic exams was 30%. The UT examination found one 4 inch long indication in the opening for the NIE nozzle. This indication characterized as service induced was located in the bottom side of the H-9 weld. The indication does not penetrate in the RPV base metal.
Since the results of H-9 examinations are well bounded by the AIA analysis (Minimum 9 degrees per nozzle area), the results are satisfactory per the guidance of BWRVIP-38.
The disposition of Non-Conformance Report 02002-1616 was "Use-as-is".
The re examination interval for the Oyster Creek H-9 weld is ten years.
Refueling Outage Inspection Results for the CRD Housing Inspections:
During the 1R19 outage, AmerGen performed inspections of the CRD housings to identify any leakage from the RPV bottom head penetrations. No leakage was observed during the drywell 1000 lb. inspection performed during the initial shutdown. Under vessel inspections performed of all CRD housings during set-up activities for CRD exchange (RPV vented) did not identify any stub tube leakage.
Inspections were performed again during the RPV pressure test at approx. 1000 lbs. and no stub tube leakage was found.
NIS - 1 Report Abstract An Evaluation of the Existing Leakage with Determination of Why and Where the Leakage Occurred:
te :
During the 18R outage, AmerGen identified leakage from two CRD housings that originated from the RPV bottom head penetrations. These 2 CRD housings were roll repaired in accordance with BWRVIP-17 and successfully sealed.
No other CRD housings were found to be leaking.
Inspections were again performed during two forced outages in Cycle 18. Under vessel leakage inspections were performed during planned drywell entries and no stub tube leakage was observed.
During the 1R19 outage, a planned visual inspection of the 2 roll repaired stub tubes was performed in an attempt to find the root cause of the leakage identified in 18R outage.
An adjacent control rod guide tube was removed to provide access through the core plate for stub tube inspection. Visual inspection of stub tubes 42-43 and 46-39 did not identify any potential leakage paths. The visual inspection was limited to sixty percent of each stub tube. This was due to the limited accessibility in the bottom head region of the RPV.
The most probable root cause of stub tube leakage is a crack in the stub tube material (furnace sensitized) due to cladding weld "barrier" failure (crack in the stub tube cladding). Alloy 182 was used for some of the cladding on the stub tubes. Similar furnace sensitized stub tubes at Nine Mile Point Unit 1 (unclad) cracked creating stub tube leakage from the bottom head
- 14. Abstract of Results of Examinations and Tests Welds categorized as; B-J, C-F-1 and C-F-2 were examined to the requirements of PDI, in compliance with the amended requirements of 10CFR50.55a for implementation of appendix VIII of the ASME Section XI, 1995 Edition up to the 1996 Addenda on an accelerated basis. The ISI and IGSCC examinations that failed to satisfy code coverage were due a significant weld discontinuity (i.e. pipe to valve, pipe to pump) where only the pipe side of the weld is examined. There were no recorded indications in either of the ISI, IGSCC or Augmented examinations. Therefore no corrective measures were required.
The "one in ten year" pressure test for the reactor pressure boundary failed to meet the four-hour hold time requirements in accordance with ASME Code Case N-498-1.
Residual heat in the primary system was identified as the cause for not being able to maintain test pressure during the required four-hour soak.
A Relief Request was submitted to the NRC address the result of the ASME Section XI pressure test.
- 15. Abstract of Corrective Measures See table 3 for IVVI inspection items. For ISI components not associated with IVVI no indications were detected by examinations, and there was no leakage at mechanical connections or through-wall leakage at the pressure boundary.
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner: AmerGen Energv Co. L.L.C., 200 Exelon Way. Kennett Square. PA tName anU Address or Owner)
- 2. Plant: Oyster Creek Nuclear Generating Station, U.S. Route 9 South, Forked River, NJ 08731 (Name and Address of plant)
- 3. Plant Unit: Oyster Creek
- 5. Commercial Service Date: 12/23169
- 7. Components Inspected: See Attach
- 4. Owner Certificate of Authorization (if required) None 6.National Board Number for Unit: Reactor Vessel 14895 Note:
Supplemental sheets in form of lists sketches, or drawings may be used, provided (1) size is 81/2 in x 1I in (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the of this form
FORM NIS-1 (back)
- 8. Examination Dates I 1/17/2000 to 10/27/2002 9
Inspection Period Identification: Third period
- 10. Inspection Interval Identification Third Inspection Interval
- 11. Applicable Edition of Section XI 1986 Addenda none
- 12. Date/Revision of Inspection Plan: 12/20/2001 Rev. 6
- 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
See Attach
- 14. Abstract of Results of Examinations and Tests See Attach
- 15. Abstract of Corrective Measures. See Attach We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of ASME Code,Section XI Certificate of Authorization No. (if applicable) None
___xpiaton Date N/A Date: bec. 3/
20AX Signed_,
By__-__,_____
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned holding a valid commission by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employ by HSB of CT of Hartford. Connecticut have inspected the components described in this Owner's Report during the period I-11.- oc to and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes and warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of an kind arising from or connected with this inspection.
S.--Commission NB 5478 (I) (N) NJ442
,ý
/n pbQror ignatur/
National Board, State Province, and Endorsements Date rt?..ar 7 20 0 3
TABLE 1 STATISTICS FOR ISI EXAMINATIONS PERIOD 1 PERIOD 2 PERIOD 3 CATEG ITEMNO TOTAL 14R 15R 16R 17 17R 18R 19R B-A B1.12 12 12 B-A B1.21 1
1 B-A B1.22 I
1 B-A B1.30 1
1 B-A B1.40 2
2 B-D B3.100 24 1
7 8
7 1
B-D B3.90 24 1
7 8
7 "1
B-E B4.11 2
1 1
B-E B4.12 22 20 1
1 B-E B4.13 6
1
.5 B-F B5.10 50 3
16 15 12 4
B-F B5.130 8
4 2
2 B-F B5.140 1
1 B-F B5.20 2
2 B-G-1 B6.10 4
2 1
1 B-G-1 B6.190 3
2 1
B-G-1 B6.20 5
1 1
3 B-G-1 B6.40 3
1 1
1 B-G-1 B6.50 9
3 3
1 3
B-G-2 B7.50 3
1 2
B-G-2 B7.60 2
1 1
B-G-2 B7.70 24 11 3
4 4
2 B-G-2 B7.80 5
5 B-J B9.11 258 18 61 64 8
8 73
-,ý26 B-J B9.12 162 32 54 64 12 B-J B9.21 16 1
1 1
1 5
4 3
B-J B9.22 2
2 B-J B9.31 8
4 4
B-J B9.32 8
1 2
1 1
3 B-J B9.40 52 6
13 13 5
5 10 B-L-2 B12.20 5
4 1
B-M-1 B12.40 1
1 B-M-2 B12.50 22 5
10 4
3 B-N-1 B13.10 77 34 2
38 2
1
"PERIOD I PERIOD 2 PERIOD 3 CATEG ITEMNO TOTAL 14R 15R 16R 17 17R 18R 19R B-N-2 B13.20 14 1
6 1
6 B-N-2 B13.30 28 14 12 2
B-N-2 B13.40 37 16 15 1
1 4
B-0 B14.10 3
1 2
B-P B15.10 6
1 1
1 111 1
C-A C1.10 3
2 1
C-A C1.40 6
2 4
C-B C2.21 4
4 C-B C2.31 3
1 1
1 C-B C2.33 18 8
2 8
C-C C3.20 11 2
7 2
C-D C4.20 2
2 C-F-1 C5.11 63 4
15 17 27 C-F-1 C5.12 6
4 2
C-F-2 C5.51 114 26 14 26 42 6
C-F-2 C5.81 1
1 C-H C7.30 16 14 2
D-B D2.10 10 10 D-B D2.20 42 7
7 10 17 1
D-B D2.40 15 3
2 2
8 D-B D2.50 1
1 D-C D3.10 3
3 D-C D3.20 9
2 3
2 2
D-C D3.30 1
1 F-A F1.10 74 12 9
16 6
25
'6 F-A F1.20 77 7
15 13 34 6
2 F-A F1.30 31 7
6 16 2
F-A F1.40 30 3
3 10 11 1
'2 F-A F1.41 35 3
7 8
8 5
,4 TOTAL 1488 239 329 366 217 36 2021 99 PERCENT 38%
42%
20%
- . Relief Requests shall be submitted for those examinations that did not meet ASME Code coverage
TABLE 2 ISI LIMITED EXAMINATIONS
- EXMNO+.*[
MTHO REMNT;[ STATUE I'LMITIED CVRAGE EXAMNO
[CATEG, ITEMNO
,...,,COMPONENTID ]
DESCRIPTION.
METHOD rEQMNT L
D COVER 000005008 D
MV-5-0001 WELD FLANGE TO TEE UT IGS COMP Yes 50 000005004 D
ND-10-0008 WELD VALVE TO ELBOW UT IGS.
COMP Yes 46 000005005 D
ND-10-0009 WELD PIPE TO VALVE UT IGS COMP Yes 50 000005012 C
NE-5-0002 WELD SAFE END TO ELBOW UT IGS Comp Yes 50 000005013 C
NE-5-0022A WELD iSAFE END TO ELBOW UT IGS COMP Yes 50 000005018 C
NG-C-0023A WELD.
PIPE TO SAFE END UT IGS COMP Yes 50 000005020 D
NU-4-0002 WELD ITEE TO VALVE UT IGS" COMP Yes 50 000002699 B-J B9.11 NE-5-209 WELD INACCESSIBLE DUE TO PIPE LUT ISI COMP Yes 0
ICLAMP 000002700 B-J B9.11 NE-5-209 WELD INACCESSIBLE DUE TO PIPE SUR ISI ICOMP Yes 0
,,,_CLAMP 000000530 B-J B9.11 i NG-A-0002 WELD ELBOW TO TEE UT ISI COMP Yes 50 000000531 B-J B9.11 NG-A-0002 WELD ELBOW TO TEE SUR ISI COMP Yes 50 000000547 B-J B9.11 NG-C-0001A WELD SAFE-END TO ELBOW SUR ISI CaMP Yes 50 000000546 B-J B9.11 NG-C-0001A WELD SAFE-END TO ELBOW UT ISI COMP Yes 50 000001809 B-J B9.11 NG-D-0022A WELD PIPE TO SAFE-END SUR IS1 iCOMP Yes 50 000001810 B-J B9.11 NG-D-0022A WELD PIPE TO SAFE-END UT ISI COMP Yes 50 000000560 B-J B9.11 NG-E-0001A WELD SAFE-END TO ELBOW SUR ISI I COMP Yes 50 000000559 B-J B9.11 NG-E-0001A WELD !SAFE-END TO ELBOW UT ISI COMP Yes 50 000000101 B-D B3.100 NR02 6-567 WELD IN9 CRD HYDR RETURN UT IS1 CoMP Yes 75 NOZZLE 000000100 B-D B3.90 NR02 6-567 WELD N9 CRD HYDR RETURN UT ISI COMP Yes 75 NOZZLE 000000641 B-J B9.11 NU-3-0001 WELD PIPE TO BRANCH SUR ISI COMP Yes 50 000000640 B-J B9.11 NU-3-0001 WELD PIPE TO BRANCH UT IS1 COMP Yes 50 000000429 B-J B9.11 NU-4-0001 WELD BRANCH TO TEE SUR ISI COMP Yes 50 000000428 B-J B9.11 NU-4-0001 WELD IBRANCH TO TEE UT ISI COMP Yes 50
NIS-1 REPORT NIS-1 REPORT ABSTRACT TABLE 3 Reactor Vessel and Internals COMPONENT DEFICIENCY DISPOSITION Shroud Support H9 weld 30% UT of H-9 from the OD (Drywell).
Use as-is per analysis. Re-inspect in UT inspected H-9 weld in Nozzle Ni A, accordance with BWRVIP NIC and N1E bioshield openings.
requirements.
Found one 4" long indication in the NiE nozzle area. This "service induced" indication is in the bottom side of the H9 weld and does not penetrate into the base metal of the RPV.
Steam Dryer Linear indications were identified at the Use as-is per analysis. Re-inspect top of two of the vertical skirt welds.
during the next Refuel Outage.
The indications run in the horizontal direction and were located where a large block is welded to the skirt assembly beneath the hold-down latch assemblies at approx. 45 and 135 degrees azimuth.
Core Spray Nozzle Foreign material was found lodged Use as-is per analysis. Potential flow inside one of the core spray sparger restriction of this one nozzle was nozzles on system 2.
determined to be acceptable.
Re-inspect during the next Refuel Outage.
RPV Cladding An area of RPV cladding containing Use as-is per analysis. Re-inspect previously reported linear indications during the next Refuel Outage.
was re-examined to determine if there was any change since the previous examination. An additional cladding indication was identified adjacent to the examination area.
RPV Head Stud An area of threads on stud #1 was found Use as-is per analysis. Damaged area damaged. Thread damage was reported of threads was cleaned using a thread as deformed threads over a 1" wide by die until the nut ran easily over the 10" long area.
damaged thread area. Stud was also UT inspected - no indications were found.
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION L.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE B-E 64.11 B-E B4.13 B-E 64.13 B-E B4.13 B-F 65.10 B-F 65.10 B-F 65.10 B-F B5.10 IS[
ISI ISI ISI ISI ISI ISI ISI 000004466 VT-2 000003344 VT-2 000003348 VT-2 000003355 VT-2 000004313 UT 000001854 SUR 000004312 SUR 000004314 UT NR02 10-566 WELD NR02 11-567A WELD N13B NOZZLE REINFORCEMENT WELD ON OD NR02 12-567A WELD N13A NOZZLE REINFORCEMENT WELD ON OD NR02 9-567E WELD N14B NOZZLE TO VESSEL WELD ON ID NR02 1-566B WELD N5B ISOLATION COND NOZZLE SAFE END NR02 5-567 WELD N9 CRDR NOZZLE SAFE END NR02 1-566B WELD N51 ISOLATION COND. NOZZLE SAFE END NR02 1-566A WELD N5A ISOLATION COND. NOZZLE SAFE END Tuesday, January 07, 2003 Page 1 of 10 1.
221 SA336 221 ATACH 221 ATACH 221 NOZZ 10" 0 594" SA336 SA336 SA336 12-Oct-02 SA336 13-Oct-02 SA336 09-Oct-02 SA336 12-Oct-02 SA336 3"
0 3" 221 CIRC 221 CIRC 221 CIRC 221 CIRC 10" 0.594" 10" 0.594" Page I oflO0 Tuesday, January 07, 2003
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION I.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE B-F 15.10 ISI B-F 85.130 ISI B-F B5.130 ISI B-F B5.20 B-G-1 B6.10 B-G-1 86.20 B-G-1 B6 20 B-G-1 B6.20 ISI ISI ISI ISI ISI 000004315 SUR 000000160 SUR 000000159 UT 000001904 SUR 000000825 UT 000000828 UT 00000828 SUR 00000828 UT NR02 1-566A WELD N5A ISOLATION COND. NOZZLE SAFE END RHC-2-0037 PIPE TO REDUCER SOCKET RHC-2-0037 PIPE TO REDUCER SOCKET WELD WELD NR02 7-566 WELD N12 CORE DIFFERENTIAL PRESS. SAFE END TO N NR02 573-02 BOLT CLOSURE NUT 44 THROUGH 64 NR02 573-01 BOLT CLOSURE STUD 47-48-49-50 NR02 573-01 BOLT CLOSURE STUD 47-48-49-50 NR02 573-01 BOLT CLOSURE STUD 44 THRU 46 AND 51 THRU 64 Tuesdaj January 07, 2003 rage. OJ 1(1 221 CIRC 216 216 221 CIRC 10" 0.594" 6"
0.337" 6"
0.337" 2-"
0.562" 9 375" 7"
6-"
54.825 6-"
54.825 6"
54.825 09-Oct-02 SA336 11-Oct-02 SA 312 TP 316 11-Oct-02 SA 312 TP 316 SB 166 10-Oct-02 SA193 13-Oct-02 SA193 13-Oct-02 SA193 10-Oct-02 SA193 221 221 221 221 rvage z of I Tuesday,; January 07, 2003
NIS-I OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE B-G-1 B640 B-G-1 B6.50 B-G-1 B650 B-G-1 B6.50 B-J B9.11 B-J B9.11 B-J B9.11 B-J B9.11 iSI ISI ISI ISI ISI ISI ISI ISI 000000831 UT 000000840 VT-I 000000834 VT-1 000000837 VT-i 000001887 UT 000001886 SUR 000004321 UT 000004322 SUR NR02 563-02 THREADS IN RXVESSEL FLANGE BOLT NR02 573-08 BOLT CLOSURE WASHER UPPER 44 THRU 64 NR02 THREADED BUSHING (64) 573-06 BOLT NR02 573-07 BOLT CLOSURE WASHER BOTTOM 44 THRU 64 WELD NE-2-225 ELBOW TO PIPE NE-2-225 ELBOW TO PIPE ND-10-0002 ELBOW TO PIPE ND-10-0002 ELBOW TO PIPE WELD WELD WELD Tuesday, January 07, 2003 Page 3 of 10 221 221 221 221 211 211 229" 28.562 9 375" 1.125" 7"
8.5" 9 375" 1.125" 8-"
0 555" 8"
0 555" 6-"
0.432" 6"
0.432" 09-Oct-02 SA336 09-Oct-02 SA193 09-Oct-02 SA193 09-Oct-02 SA193 12-Oct-02 SA 312 TP 316 12-Oct-02 SA 312 TP 316 09-Oct-02 SA 312 TP 316 09-Oct-02 SA 312 TP 316 215 215 Page 3 of 10 Tuesday, January 07, 2003
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE B-J B9.11 B-J B9.11 B-J B9.11 B-J B9.11 B-J B9.11 B-J B9.11 B-J B9.11 B-J B9.11 ISI ISI IS' ISI ISI ISI Is[
ISl 000000549 UT 000000550 SUR 000000588 UT 000000589 SUR 000000590 UT 000000591 SUR 000000593 SUR 000000592 UT NG-C-0022 PIPE TO ELBOW NG-C-0022 PIPE TO ELBOW MS-1-0055 PIPE TO ELBOW MS-1-0055 PIPE TO ELBOW MS-1-0056 ELBOW TO PIPE MS-1-0056 ELBOW TO PIPE MS-1-0083 PIPE TO ELBOW MS-1-0083 PIPE TO ELBOW Tue¶day, January 07, 2003 Page 4 of 1(1 WELD WELD WELD WELD 223 223 411 411 411 411 411 411 WELD 26" 1.219" 26" 1.219" 24" 1.218" 24" 1.218" 24" 1.218" 24" 1 218" 24" 1.218" 24" 1.218" 14-Oct-02 A376 TP 316 13-Oct-02 A376 TP 316 10-Oct-02 A106 GR B 10-Oct-02 A106 GR B 10-Oct-02 A106 GR B 10-Oct-02 A106 GR B 08-Oct-02 A106 GR B 02-Sep-00 A106 GR B WELD WELD WELD Page 4 o 0.'I Tuevday, January 07, 2003
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION I.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19RTABLE 1 CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE B-J 89.21 B-J B9 21 B-J B9 21 B-J B9.32 B-J B9 32 B-J B9 32 B-J B9.40 B-J B940 ISI ISI ISI is[
ISI ISI Is[
ISI 000000632 SUR 000003049 SUR 000000639 SUR 000001876 SUR 000000659 SUR 000000660 SUR 000000762 SUR 000000764 SUR NG-B-0009 PIPE TO FLANGE DECON CONN NC-4-0001 B SAFE-END TO SAFE-END NC-4-0017 PIPE TO ELBOW NG-C-0006 ELBOW TO BRANCH NG-D-0017 PIPE TO BRANCH MS-1-0034 PIPE TO BRANCH RHC-2-0026 ELBOW TO PIPE SOCKET RHC-2-0030 ELBOW TO PIPE SOCKET T..
Ja n.
ary-- 0 7, 2 0 0 3..
r a ge...
IU.Z 223 225 225 223 223 411 WELD WELD WELD WELD WELD WELD WELD WELD 2"
0.218" 3"
0 300" 3"
0 300" 1.5*
0.200" 2"
0 218" 2"
0218" 2"
0218" 2"
0.218" 08-Oct-02 A376 TP 316 13-Oct-02 SA 312 TP 316 13-Oct-02 SA 312 TP 316 14-Oct-02 A376 TP 316 10-Oct-02 A376 TP 316 10-Oct-02 A106 GR B 11-Oct-02 SA 312 TP 316 12-Oct-02 SA 312 TP 316 216 216 Page 5of 10 Tuesday, January 07, 2003
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE
.AIM r%
9" 14-Oct-02 B-J B940 B-J B940 B-J B9.40 B-J B9.40 B-J B9.40 B-J B9.40 B-J B940 B-J B9.40 Is' IS' ISI ISI ISI ISI ISI ISI 0UUU00(83 SUR 000000786 SUR 000000790 SUR 000000793 SUR 000000800 SUR 000000801 SUR 000000805 SUR 000000806 SUR NPIP TA-UO UE PIPE TO ELBOW NG-B-0026 PIPE TO ELBOW NG-C-0029 TEE TO PIPE SOCKET NG-D-0032 VALVE TO PIPE MS-9-0007 VALVE V-1-0107 TO PIPE SOCKET MS-9-0011 NOZZLE TO PIPE SOCKET MS-9-0020 TEE TO PIPE SOCKET MS-9-0024 0.218" A106GR B
ý- ~ ~ ~ ~
~
~
~
~
~
~
~
~
~
~ ~ ~ ~ ~ ~ rg.
INU11Al
- 0 10100111-1...
W llmlll.....
1 it)
Tuesday, January 07, 2003 VV*L*
WELD WELD WELD WELD WELD WELD WELD 223 223 223 22.3 411 411 411 411 A376 TP 316 14-Oct-02 A376 TP 316 14-Oct-02 A376 TP 316 10-Oct-02 A376 TP 316 0.218" 2
0.218" 2-"
0.218" 2
0.218" 2
0.218" 2"
0.218" 2-"
0.218" 2-"
A106 GR B 1 0-Oct-02 A106 GR B 14-Oct-02 A106 GR B 10-Oct-02 15-Oct-02 Irugv I jli
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MATL DATE B-M-1 B12.40 ISI B-N-1 B13.10 ISI B-N-2 B13 20 ISI B-N-2 B13 20 ISI B-N-2 B13.20 ISI B-N-2 B13.20 ISI B-N-2 B13 20 ISI B-N-2 B13 20 ISI UUUUUoU1U UT/SUR 000004216 VT-3 000001419 VT-1 000001424 VT-i 000001414 VT-i 000001409 VT-1 000001429 VT-I 000001404 VT-1 411 8
uo-v'J-u,"
A105 GR II 222 0
0 0
0 0
0 0
0 V-1-176 WELD EMRV VALVE BODY WELD NR02 INTERNAL VESSEL RX VESSEL INTERIOR SURFACES NR02 6-587A WELD SURV SPECIMEN HOLDER BRACKET LOWER NR02 6-587B WELD SURV SPECIMEN HOLDER BRACKET LOWER NR02 5-587C WELD SURV SPECIMEN HOLDER BRACKET UPPER NR02 5-587B WELD SURV SPECIMEN HOLDER BRACKET UPPER NR02 6-587C WELD SURV SPECIMEN HOLDER BRACKET LOWER NR02 5-587A WELD SURV SPECIMEN HOLDER BRACKET UPPER SS CLAD SA336 SA336 SA336 SA336 SA336 SA336
v.f In rug / UJ iu Tuesday, January 07, 2003 221 ATACH 221 ATACH 221 ATACH 221 ATACH 221 ATACH 221 ATACH 0
0 0
0 0
0
-rugu / Uj Iv
NIS-! OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/2311969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE B-N-2 B13.30 ISI B14-10 ISI B14-10 ISI C-A C1.10 ISI C3.20 ISI C-C C320 D-C D3 20 D-C D3.20 ISI ISI ISI 000001460 VT-3 000004975 SUR 000004975 SUR 000001695 UT 000002022 SUR 000002024 SUR 000002099 VT-3 000002103 VT-3 NR02 TRACK GUIDE BRACKET NC02 NC02 18-03 NC02 NR02 06-11 H-21-OOIC SHELL TO FLANGE WELD 422-BP-726-734-0014 A
RESTRAINT (RF-2-H26) 422-BP-726-734-0014 B
RESTRAINT (RF-2-H31) 3-587A WELD CDRIVE CDRIVE W-1 WELD SUPORT SUPORT H-18-O00A H-1 SUPORT FUEL POOL HEAT EXCHANGER (NN02-A) SOUTH S H-18-OOIA H-2 SUPORT FUEL POOL HEAT EXCHANGER (NN02-A) NORTH S 221 ATACH 225 225 241 CIRC 422 RGDST 422 RGDST 251 ANCHR 251 ANCHR 0
0 6
0 678" 6"
0.678" 51 0 625" SA336 14-Oct-02 SA 312 TP 316 14-Oct-02 SA 312 TP 316 02-Oct-02 SA515/516 GR70 0
0 0
0 0
0.375" 0
0.375" 16-Oct-02 15-Oct-02 06-Oct-02 SA 36 06-Oct-02 SA 36 V-R At 10 Tuesday, January 07, 2003 B-0 B-0 C-C
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MATL DATE F-A F1.10 F-A F1.10 F-A F1.10 F-A F1.10 F-A F1.10 F-A F1.20 F-A F1.20 F-A F1.40 ISI Is' IS' ISI ISI Is' IS' ISI ISI ISI 000000111 VT-3 000000105 VT-3 000002198 VT-3 000002331 VT-3 000000192 VT-3 000002292 VT-3 000000469 VT-3 000000671 VT-3 211-BP-634-R14-0022 MECHANICAL SNUBBER 211-BP-NE-2-H2A-0024 VARIBLE SPRING HANGER 215-BP-X-10-SS-1-0014 MECHANICAL SNUBBER 225-BP-NC-2-H23-0015 VARIBLE SPRING HANGER 225-BP-NC-4-H2-0010 VARIBLE SPRING HANGER 241-BP-NQ-2-H20-0018 ROD HANGER 241-BP-NQ-2-H43-0068 VARIBLE SPRING HANGER 223-GR-H5(C)-0023 CONSTANT A
(ND-1-SI)
SUPORT SUPORT SUPORT SUPORT SUPORT SUPORT SUPORT A
SUPORT (NG-C-H8)
Tuesday, January 07, 2003 Page !i of 1(1 211 211 09-Oct-02 11-Oct-02 215 MSNUB 225 11-Oct-02 225 10-Oct-02 241 12-Oct-02 241 09-Oct-02 223 03-Oct-02 CON 08-Oct-02 Page 9 of 10 Tuesday, January 07, 2003
NIS-I OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTIIORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE 1 CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MA TL DATE F-A F1.40 F-A F1.40 F-A F1.40 F-A F1.40 F-A F1.40 ISI ISI ISI Is[
ISI 000000673 VT-3 000000678 VT-3 000000679 VT-3 000002226 VT-3 000002220 VT-3 223-GR-H5(C)-0023 CONSTANT B
(NG-C-H9) 223-GR-SS-2(C)-0032 A
MECHANICAL SNUBBER (NG-C-S5) 223-GR-SS-2(C)-0032 B
MECHANICAL SNUBBER (NG-C-S6)
SUPORT SUPORT SUPORT H-18-001A H-2 SUPORT FUEL POOL HEAT EXCHANGER (NN02-A) NORTH S H-18-OOIA H-1 SUPORT FUEL POOL HEAT EXCHANGER (NN02-A) SOUTH S IugL' HI CFJ It
Tuesday, January 07, 2003 223 CON 08-Oct-02 08-Oct-02 223 MSNUB 223 MSNUB 251 ANCHR 251 ANCHR 08-Oct-02 03-Oct-02 SA 36 03-Oct-02 SA 36 rauge I U ji 'IU
Attachment II Form NIS - 1 Section IWE
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner: AmerGen Energv Co. L.L.C., 200 Exelon Way. Kennett Square. PA
(.aame andL Address or Owner)
- 2. Plant: Oyster Creek Nuclear Generating Station. U.S. Route 9 South, Forked River, NJ 08731 (Name and Address of plant)
- 3. Plant Unit: Oyster Creek
- 5. Commercial Service Date: 12/23/69
- 7. Components Inspected: See Attach
- 4. Owner Certificate of Authorization (if required) None 6.National Board Number for Unit: Reactor Vessel 14895 Note:
Supplemental sheets in form of lists sketches, or drawings may be used, provided (I) size is 81/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the of this form
FORM NIS-1 (back)
- 8. Examination Dates 11/17/2000 to 10/27/2002 9
Inspection Period Identification: Second Period
- 10. Inspection Interval Identification First Inspection Interval
- 11. Applicable Edition of Section XI 1992 Addenda 1992
- 12. Date/Revision of Inspection Plan: 12/31/2001 Rev 1
- 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
- 14. Abstract of Results of Examinations and Tests
- 15. Abstract of Corrective Measures We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of ASME Code,Section XI Certificate of Authorization No. (if applicable) None Expi n Date N_/A Date: '
~
.20_j5LaSigned.,Z-A
/
D CERTIFICATE OF INSERVICE INSPECTION I, the undersigned holding a valid commission by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employ by HSB of CT of Hartford. Connecticut have inspected the components described in this Owner's Report during the period 11-11-ae to to-Pk:-,a and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes and warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
0
.d*
l
.wa&.
Commission NB 5478 (1) (N) NJ442 Inspector'siglgature V
National Board, State Province, and Endorsements DateJ'nadrY 7 20d3
NIS-1 REPORT ABSTRACT
- 13.
Abstract of Examinations and Tests.
Oyster Creek is in the second period of the first inspection interval for containment inspections. These examinations were performed to fulfill the requirements of ASME Section XI, 1992 Edition up to and including the 1992 Addenda. Fourteen examinations were performed on the Oyster Creek Nuclear Generating Station primary containment. These examinations included Manway bolting on the Torus, and the Drywell Personnel Air Lock, and containment penetrations on the inside of the Torus. A list identifying these components has been attached.
- 14.
Abstract of Results of Examinations and Tests In conjunction with the examinations of the Torus penetrations, an inspection of the Torus interior above the water level was also conducted. The Torus interior was found to be in good condition. However, there was evidence of water staining on the vessel wall in a few locations. But there was no noticeable degradation of the protective coating. The examination for bolt integrity found the containment bolting to be acceptable with no evidences of corrosion
- 15.
Abstract of Corrective Measures Only minor indications were recorded as a result of bolting inspection on the Drywell Personnel Hatch. Items such as missing cotter pins. All deficiencies were corrected on the spot.
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE 1 CA TEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MATL DATE E-A E1.11 E-A E-A E1.11 E1.11 E-A E1.11 E-A E1.11 E-A E-A E-A E1.11 E1.11 E1.11 ISI ISI ISI ISI ISI ISI ISI 000004718 VT-G 000004735 VT-G 000004734 VT-G 000004733 VT-G 000004732 VT-G 000004731 VT-G 000004730 V'-G 000004726 VT-G X-052 PENETR PIPING PENETRATION FOR DWVENT LOW POINT X-058 J
PENETR PIPING PENETRATION FOR DWVENT LOW POINT X-058 I
PENETR PIPING PENETRATION FOR DWVENT LOW POINT X-058 H
PENETR PIPING PENETRATION FOR DWVENT LOW POINT X-058 G
PENETR PIPING PENETRATION FOR DWVENT LOW POINT X-058 F
PENETR PIPING PENETRATION FOR DWVENT LOW POINT X-058 E
PENETR PIPING PENETRATION FOR DWVENT LOW POINT X-058 D
PENETR PIPING PENETRATION FOR DWVENT LOW POINT Monday, December 30, 2002 rage i OJ 2 09-Oct-02 10-Oct-02 10-Oct-02 10-Oct-02 244 MECH 244 MECH 244 MECH 244 MECH 244 MECH 244 MECH 244 MECH 244 MECH 10-Oct-02 10-Oct-02 10-Oct-02 10-Oct-02 Page I oj 2 Monday, December 30, 2002
NIS-I OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 3.UNIT:
OYSTER CREEK NUCLEAR GENERATING STATION 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED) NONE 5.COMMERCIAL SERVICE DATA 12/23/1969 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL, 14895 OUTAGE 19R TABLE I CATEG ITEM# REQMNT EXAMNO COMPONENT SYS#
DIA" EXAM METHOD DESCRIPTION TYPE THICK" MATL DATE E-A E1.11 ISI 000004725 X-058 C
PENETR 244 10-Oct-02 VT-G PIPING PENETRATION FOR DWVENT LOW POINT MECH E-A E1.11 ISI 000004724 X-058 B
PENETR 244 10-Oct-02 VT-G PIPING PENETRATION FOR DWVENT LOW POINT MECH E-A E1.11 ISI 000004723 X-058 A
PENETR 244 1O-Oct-02 VT-G PIPING PENETRATION FOR DWVENT LOW POINT MECH E-G E8 10 IS 000004985 NRO1 HATCH BOLT 187 17-Oct-02 VT-1 DRYWELL PERSONNEL LOCK BOLTING E-G E8.10 ISI 000004987 TORUS MANWAY BOLT 187 17-Oct-02 VT-1 TORUS SUPPRESSION CHAMBER MANWAY BOLTI E-G E8 10 ISI 000004986 TORUS MANWAY BOLT 187 17-Oct-02 VT-I TORUS SUPPRESSION CHAMBER MANWAY BOLTI Monday, December 30, 2002 Page 2 of 2 Monday, December 30, 2002 Page 2 of 2
Attachment III Form NIS - 2 Repairs and/or Replacements
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L L.C.
Name 200 EXELON WAY. KENNETT SOUARE. PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH. FORKED RIVER. NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNET'T SQUARE, PA Address Date December 13, 2002 Sheet I of 2 Unit OYSTER CREEK C2002277 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A
- 4.
Identification of System SERVICE WATER AND EMERGENCY SERVICE WATER (531) & (532)
- 5.
(a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda,N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year
- Repaired, Code Component Manufacturer Serial No.
Board Other Identification it Replaced, or Stamped No.
Replacement (Yes or
_No)
- 7.
Description of Work Modification welding of 12". 20" rioe cross tie between Service Water & Emergency Service Water
- 8.
Tests Conducted Hydrostatic X Pneumatic Nominal Operating Pressure X Other Pressure Hydro 375 psi Test Temp.Ambient OF)
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47kh St., New York, NY 10017 AG0527 (05/01)
FORM NIS-.2 (Back)
- 9.
Remarks: This modification was to add a cross tie connection by welding between the Emergency Service Water System Applicable Manufacturer's Data Reports to be attached and the Service Water System Portion of the work was welded in a fabrication shoo and the rest of the piping was welded on site The spools pieces in the Fab shop was hydro. and the tie in welds in site was pressure tested using Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expir Signe d 0 r rwn' Design~ee Title atinn Date N/A Date At-e- #,
Z!?-.,
?,20 e, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report dunng the period 6/03/02 to 12/13/02
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__Commissions NB 5478 (1) (N) NJ442 Inspector's Signature#
National Board, State, Province, and Endorsements D
20 D ate A
,* r "
/
2002 AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Address Date December 12, 2002 Sheet 1
of 2
Unit OYSTER CREEK WORK ORDER C2003920 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A l.AAp 1O.nirt nn 11T.h.,*,
tna J.Vlkk
-fl L.,U%_____________________________
1'J/A
- 4.
Identification of System SERVICE WATER SYSTEM (531)
- 5.
(A) Applicable Construction Code 1331:1 1955 Edition, N/A
" "Addenda, N416-4'".
Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer Yea
- Repaired, Code Board Other Identification ilt Replaced, or Stamped Component Manufacturer Serial No.
N.Bui Rpacmnt (eso No.
Replacement (Yes or No)
See Page 2
- 7.
Description of Work Repalce Valve V-3-324
- 8.
Tests Conducted Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure 1000
-psi Test Temp. 500 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 471h St., New York, NY 10017 AG0527 (05101)
FORM NIS-2 (Back)
Remarks This was a welded renlacement of a two inch Valve V-3-324. The weldini* was nerformed on site by AmerGen Energy.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A
____Expiration Date N/A Date,,-,-/
C&1C'*
,20 e
s De1gee, Title Certificate of Authorization No. N/A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT. Have inspected the components described in this Owner's Report during the period 9 / 30 / 02 to 11/10/02, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or jiroperty danmage or a loss of any kind arising from or connected with this inspection.
(7jzAo4 //L&,
/
l "nspectort* 'inature Date BSC e Commissions NB 5478 (I1 (N) NJ442 2007-National Board, State, Province, and Endorsements AG0527 (05/01) 9.
Remaks Tis ws a elde renAppli ofableoManchfalvuer' V-3-32 ReoTshoe wednasttach red o
ieb m
FORM NIS-2 OWNER'S REPORT-FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXELON WAY. KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Address Date December 10, 2002 Sheet I of 2 Unit OYSTER CREEK C2002348 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A
- 4.
Identification of System Main Steam System 411
- 4.
- 5.
(a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components. See Item 7 ASME Name of Name of Manufacturer National Year
- Repaired, Code Board Other Identification Replaced, or Stamped Component Manufacturer Serial No.No Built Rel c m n (Y so No.
Replacement (Yes or No)
- 7.
Description of Work Replace valve V-1-1 10 by welding and associated piping
- 8.
Tests Conducted Hydrostatic X Pneumatic _
Nominal Operating Pressure __
Other _
Pressure 1875 psi Test Temp.AMBIENT
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/22 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4 7th St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9.
Remarks Replace 2 inch valve V--I1 10 and connecting piping Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI..
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed G..-Z_
wner wner esignee, Title Date
'ibe.,a,,<l/e AG0527 (05/01)
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT. Have inspected the components described in this Owner's Report dunng the period 02/21/02 to 11/10/02, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descnbed in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
National Board, State, Province, and Endorsements A'e'in 1
6fP
/6
.20 O
Date Ake l
ý/
- fns-p ecto'N-Si g-nature U
VT1 IZA7Q /I'% tXT XTTAA)
'*..*,,.ntliiilA*-iuii*.
I*I.P d'-I' to l1I
- 1*1I i*lj'-t'l/.
Expiration Date N/A
/at
,20_6,2.__1 2 0 001
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Address Date November 15. 2002
, Sheet I
of 2
Unit OYSTER CREEK WORK ORDER C2002374 and C2001981 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A Ar:f)Ji ali.,,
n.a +_______________________________
Pvn;rot;nn Tht,,
- 4.
Identification of System CONTROL ROD DRIVE SYSTEM (225)
- 5.
(a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda,_
'Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
ASME Nameof Nameof Manufacturer National Year
- Repaired, Code Compoente Manufacturer a NBoard Other Identification it Replaced, or Stamped Component Manufacturer Serial No.
No.
Replacement (Yes or SeePage_2 No)
See Page 2
- 7.
Description of Work Repalce CRDs and bolting
- 8.
Tests Comiducted Hydrostatic Pneumatic _
Nominal Operating Pressure X Other Pressure 1020 psi Test Temp. 220 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4 7th St., New York, NY 10017 AG0527 (05/01)
KI/A
FORM NIS-2 (Back)
- 9.
Remarks The purpose of this activity was to perform CRD replacement for refueling outage 1 R19. Twenty drives were replaced and the bolting was inspected for a visual VT-I examination per ASME Section XI Category B-G-2, Item no.B7 80.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authonzation No. N/A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report during the period 9 / 30 / 02 to 6-Z IS-CZ_
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
a z
Z....
.4 --
Commissions NB 5478 (1) (N) NJ442 f
A u /,s-Date National Board, State, Province, and Endorsements AG0527 (05/01)
Exniratinn Date N/A
.1
)
l*Owne r Ow-ne~r's De'signee, ýflýt 1
hate i,%
J'g f
,ý7--1*ec-(or`sSi`gnYtWe
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXEL.ON WAY. KFNNFTT qOIIARF PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Address Date November 12. 2002
, Sheet 1
of 2
Unit OYSTER CREEK WORK ORDER C2003972 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A "1.1/A
- 4.
Identification of System CONTROL ROD DRIVE RETURN SYSTEM HCU (225)
- 5.
(a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
- 7.
Description of Work Replace valve V-305-106 for HCU 22-27
- 8.
Tests Conducted Hydro~tatic Pneumatic__
Nominal Operating Pressure X Other _
Pressure 1000 psi Test Temp.500 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 /2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4 7th St., New York, NY 10017 AG0527 (05/01)
V
+'
r,% +
'KT/A AF 10 V11 a ý I*A [311 laLIUII It,t GLK, l*l/"a-
FORM NIS-2 (Back)
- 9.
Remarks This was a welded replacement of a 1/2" valve on the Hydrallic Control Units, Welding was performed on Applicable Manufacturer's Data Reports to be attached Site by AmerGen Energy.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A AG0527 (05/01)
Expiration Date N/A Certificate of Authorization No. N/A SignedV
'JLLI~IL
~J.A~Iflf.
20 i CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report during the period
/0
/4-to
//-
-/-
0 2
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
a A,,...
- Commissions NB 5478 (1) (N) NJ442
- nspiector's Signat National Board, State, Province, and Endorsements Date
__2_
20 d Tlt //- 1-,- C ýZ_
er or~l*
wner s/II* es gnmlII;*
1 ll
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
-Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
'3.
Work Performed by AmerGen Energy Co LLC Name Date-November 12. 2002 Sheet 1
of 2
Unit OYSTER CREEK WORK ORDER C2003968 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A 200 EXELON WAY, KENNETT SQUARE, PA Expiration Date N/A Address
- 4.
.Identification of System CONTROL ROD DRIVE RETURN SYSTEM! HtU (225)
- 5.
(a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
- 7.
Description of Work Replace valve V-305-106 for HCU 22-03
- 8.
Tests Conducted Hydrostatic Pneumatic Nominal Operating Pressure X Other _
Pressure 1000 psi Test Temp.500 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 V2 x II in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4 7th St,New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9.
Remarks This was a welded retilacement of a 1/2" valve on the Hvdrallic Control U nits Weldino Applicable Manufacturer's Data Reports to be attached Site by AmerGen Energy.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expir.
Signed Z06 1
'4 G
, V Owne'6or Owner's Designee, Title a
ation Date N/A Date
-- 2.
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or, Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report during the period
/Z" 0Z to 1/- S-- 02
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ansing from or connected with this inspection.
Commissions NB 5478 (1) (N) NJ442 National Board, State, Province, and Endorsements D eslet 0
ature Date 20O]
/7
)07-AG0527 (05/01) 16;u V1 I WaZ5 1ý11VIIJI I
W*
II*I llll
[ll*ll llll
,2o_0_.,1
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Date November 12. 2002 Sheet 1
of 2
Address
- 4.
Identification of System CONTROL ROD DRIVE RETURN SYSTEM HCU (225)
- 5.
(a) Applicable Construction Code B331.1 1955 Edition, N/A Adden-da, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year
- Repaired, Code Component Manufacturer Serial No.
Board Other Identification it Replaced, or Stamped No.
Replacement (Yes or No)
See Page 2
- 7.
Description of Work Replace valve V-305-106 for HCU 46-39
- 8.
Tests Conducted Hydrostatic Pneumatic Nominal Operating Pressure X Other __
Pressure 1000 psi Test Temp.500 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 V2 x II in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4 7th St., New York, NY 10017 AG0527 (05/01)
Unit OYSTER CREEK WORK ORDER C2003966 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A
FORM NIS-2 (Back)
- 9.
Remarks This was a welded replacement of a 1/2" valve on the Hydrallic Control Units, Welding was performed on Applicable Manufacturer's Data Reports to be attached Site by AmerGen Enerv.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authonzation No. N/A qi"M Date
, 2OA2
' ýOwn37br 0*',e~ds Designcee, itle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report dunng the period
/0 a
- 7.
to
/[-
4-oz
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
al/,a
/a National Board, State, Province, and Endorsements r'lispecito-r' Sl~gnaturef Date A
(?-
Commissions NB 5478 (1) (N) NJ442
.20 0'Z AG0527 (05101)
Exn ratirn Dlate N/A F
Date
.&/"Ie?-
0 2-..
-,20 6,,;--
Date
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name Date-November 12, 2002 Sheet I
of 2
Unit OYSTER CREEK WORK ORDER C2003963 Repair Organization P.O. No, Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A 200 EXELON WAY, KENNETT SQUARE, PA Expiration Date N/A Address
'4.
Identification of System CONTROL ROD DRIVE RETURN SYSTEM HCU (225)
- 5.
(a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N-416-i Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
- 7.
Description of Work Replace valve V-305-106 for HCU 46-23 8
Tests Conducted Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure 1000 psi Test Temp.500 OF NOTE: Supplemental sheets in form of lists, sketches,-or drawings may be used, provided (1) size is 8 /2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form (12/82)
This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 4 7th St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9.
Remarks This was a welded replacement of a 1/2" valve on the Hydrallic Control Units, Welding was performed on Applicable Manufacturer's Data Reports to be attached Site by AmerGen Energy CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A AG0527 (05/01)
Certificate of Authorization No. N/A flate Ad iA>p AY 6
Signed fOwner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report during the period I
- /'4-. 0 Z to
/1-4--
O-
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
. Commissions NB 5478 (1) (N) NJ442 National Board, State, Province, and Endorsements Date A / /,
/2 2002-I Expiration Date N/A Ex nato ate.
N/A.
')n 4-'
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L C.
Name 200 EXELON WAY. KENNETT SOUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Address Date November 13, 2002 Sheet 1
of 2
Unit OYSTER CREEK WORK ORDER C0550853 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A
- 4.
Identification of System CONTAINMENT SPRAY SYSTEM (241)
- 5.
(a) Applicable Construction Code B31.1 "
1955 Edition, N/A Addenda,______ Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
ASME National
- Repaired, Code Name of Name of Manufacturer Nainl.
Year
- Rpie, Cd Board Other Identification Replaced, or Stamped Component Manufacturer Serial No.
No.
Built No.Replacement (Yes or No)
See Page 2
- 7.
Description of Work Upgrade and replace component support
- 8.
Tests Conducted Hydrostatic Pneumatic I Nominal Operating Pressure N/A Other Pressure _psi Test Temp.
OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 1/2/2 x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered anil the number of
-sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 4 7th St., New York, NY 10017 AG0527 (05/01) 3.
FORM NIS-2 (Back) 9.
Remarks This was a welded replacement of an integral welded attachment for hanger 241-NO-2-H33-62. The welding noc np,-fnrn-,nA nfl cit a h., A
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE' We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A SignedZ
- 4-
-/"
wne4 or Owner's besignee, Title Expiration Date N/A Date,,,-Qetk,,,1 4
4 Z
.20,0'2_
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report during the period 7 / 10 / 02 to 11 /04/02
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_S________________gnature___Commissions NB 5478 (1) (N) NJ442
,Ins tor's SignatNational Board, State, Province, and Endorsements Date
/1/4'~'- k3 20 d 2-AG0527 (05/01)
I 20 t!5 -7
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name Date November 12. 2002 Sheet 1
of 2
Unit OYSTER CREEK WORK ORDER C2001184 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A 200 EXELON WAY, KENNETT SQUARE, PA Expiration Date N/A Address
- 4.
Identification of System EMERGNECY SERVICE WATER (532)
- 5.
(a) Applicable Cofistruction Code B31.1 1989Edition, N/A Addenda, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
7.
Description of Work Installed temporary emergency service water piping
- 8.
Tests Conducted HydrostaticX Pnumatic -
Nominal Operating Pressure Other _
Pressure225psi Test temp Ambient F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 x 11 in. (2) information in items 1 through 6 on this report is included on each-sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4 7th St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9.
Remarks Applicable Manufacturer's Data Reports to be attached This replacement was for five 14 inch diameter spools for the Emergency Service Water System. This work was nerformed on site by AmerGen Energy CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate ~ ~
~
~
~
~
x ofAtoiainN.rj~aLI~l onaLL Wf DatellJe.
-,ft,
/0Ow7(Wor Owler's,Desnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components described in this Owner's Report during the penod el(l'.7-S 10o7/
to 4u t,,sr.U'r,
-d
/
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
N/IA
- §ad I
/Adl-V//
¢Inslector-s Signatu P
/%- I It
/ <
Commissions NB 5478 (1) (N) NJ442 National Board, State, Province, and Endorsements 200a3 AG0527 (05101)
Date S ign ed m
w
/.
20 e-3
ýLz, / ZZ -/- /,,
Certificate of Authorization No.
I,* t*
I*AI311d-LIUII L,/d.[*
l*l/*
FORM NIS-2 OWNER'S REPORT-FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Enery Co L.L.C.
Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
'3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Address Date November 12, 2002
-Sheet 1
of 2
Unit OYSTER CREEK WORK ORDER C2002676 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A
- 4.
Identification of System SERVICE WATER PIPING (531)
- 5.
(a) Applicable Construction Code B3 1.1 19899Edition, N/A Addenda, NACode Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6.
Identification of Components Repaired or Replaced and Replacement Components.
- 7.
Description of Work Installed pipiN spools R
Tests Conducted Hydrostatic XPneumatic Nominal Operating Pressure Other Pressure375psi Test Temp Abient F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 /21/2 xIl'in. (2) -"
information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 4 7tb St., New York, NY 10017 AG0527 (05/01) v................
FORM NIS-2 (Back)
- 9.
Remarks Applicable Manufacturer's Data Reports to be attached This replacement was for three 20 inch diameter piping spools This work was performed on site by AmerGen Energy CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT Have inspected the components descnbed in this Owner'sReportduringtheperiod
,A-,
O2 to 6 I(g..*/,,r
.1)1, 20cZ
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
4/44a.
//
, lhsj6etor, ; Sigjn? 6 Date
-* Ilfltd, ",
/A Commissions NB 5478 (1) (N) NJ442 National Board, State, Province, and Endorsements
,)0 a:?
AG0527 (05/01)
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Date-4,!t 2, f
, 20,
"- /
O er orwn's Deesignee, Title 11*........
Expiration Date. N/A
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1.
Owner AmerGen Energy Co L.L.C.
Name 200 EXELON WAY, KENNETT SQUARE, PA Address
- 2.
Plant OYSTER CREEK GENERATING STATION Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 Address
- 3.
Work Performed by AmerGen Energy Co LLC Name 200 EXELON WAY, KENNETT SQUARE, PA Date November 12, 2002
-Sheet
-I of 2
Unit OYSTER CREEK WORK ORDER C0546733 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp N/A Authorization No.
N/A Expiration Date N/A Address
- 4.
Identification of System REACTOR HEAD COOLING SYSTEM 216
- 5.
(a) Applicable Construction Code B3 1.1 1955 Edition, N/A Addenda, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6. -
Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year
- Repaired, Code Component Manufacturer Serial No.
Board Other Identification it Replaced, or Stamped No.
Replacement (Yes or No)
See Page 2
- 7.
Description of Work Replace valve V-31-5 BY WELDING
- 8.
Tests Conducted Hydrostatic Pneumatic _
Nominal Operating Pressure X Other _
Pressure I 050psi Test Temp.2200 F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8" x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47" St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9.
Remarks This was a welded replacement of a 2" valve on the Reactor head Cooling System Applicable Manufacturer's Data Reports to be attached The work was performed on site by AmerGen Energy CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Signed wnegee il Expiration Date N/A Date 22,,,i.,,
/'.
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT Have inspected the components descnbed in this Owner's Report during the period
/c-.I-d 2-.
to
/ ( o 7
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descnbed in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
e;
" IAspector's Signatle
.l/a n /.,r'v
/5 Date Commissions NB 5478 (1) (N) NJ442 20o3 National Board, State, Province, and Endorsements AG0527 (05101)
- 1