ML030020375

From kanterella
Jump to navigation Jump to search
SRO Initial License Examination November 2002
ML030020375
Person / Time
Site: Duane Arnold 
Issue date: 11/30/2002
From:
Nuclear Management Co
To:
Office of Nuclear Reactor Regulation
References
50-331/OL02-301
Download: ML030020375 (104)


Text

QF-1030-03 Rev. 0 (FP-T-SAT-30)

Retention: Life of plant insurance policy + 10 yr. Disposition: Instructor, Training Supervisor, and TAC Retain in: Training Records Duane Arnold SRO Exam.doc Rev. 0 DUANE ARNOLD SRO INITIAL LICENSE EXAMINATION NOVEMBER 2002 Docket No. 50-331 License No. DPR-49

QF-1030-03 Rev. 0 (FP-T-SAT-30)

Retention: Life of plant insurance policy + 10 yr. Disposition: Instructor, Training Supervisor, and TAC Retain in: Training Records Duane Arnold SRO Exam.doc Rev. 0 WRITTEN EXAMINATION KEY COVERSHEET Written Examination key Attach answer key to this page.

Key should contain the following:

 Enabling Objective Number

 Test Item o Question or Statement o All possible answers o Correct Answer Indicated o Point Value

 References Indicate in the following table if any changes are made to the exam after approval:

PREPARER DATE DESCRIPTION OF CHANGE REASON FOR CHANGE REVIEWER DATE Training program: Senior Reactor Operator Examination Number/Title: 2002 ILC SRO Written Exam Course/lesson plan Number(s):

50007 GRADE:

Total Points Possible: 100 PASS CRITERIA:  80%

Exam Time:

EXAMINATION REVIEW AND APPROVAL:

Submitted by:

Date:

Reviewed by:

Date:

Approved by:

Date:

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Retention: 6 years Disposition: Instructor, Training Supervisor, and TAC Retain in: Training Records Duane Arnold SRO Exam.doc Rev. 0 WRITTEN EXAMINATION COVERSHEET EXAMINATION RULES

1. References may not be used during this examination, unless otherwise stated.
2. Read each question carefully before answering. If you have any questions or need clarification during the examination, contact the examination proctor.
3. Conversation with other trainees during the examination is prohibited.
4. Partial credit will not be considered.
5. Rest room trips are limited and only one examinee at a time may leave.
6. Ensure you have answered each item prior to turning in your exam.
7. For exams with time limits:
a. You have minutes to complete the examination.
b. The proctor will collect all examinations after this time expires.

Dishonesty Policy: Cheating or compromising the exam will result in disciplinary actions up to and including termination.

I have not given, received, or observed any aid or information regarding this examination prior to or during its administration that could compromise this examinations integrity.

Examinees Signature:

Date:

I acknowledge that the correct answers to the exam questions were indicated to me following the completion of the exam. I have had the opportunity to review the examination questions with the instructor to ensure my understanding.

Examinees Signature:

Date:

TRAINEE INFORMATION:

Name:

Job

Title:

Employee Number:

Site:

DAEC Training program: Senior Reactor Operator Examination Number/Title: 2002 ILC SRO Written Exam Course/lesson plan Number(s):

50007 GRADE:

Total Points Possible: 100 Grade: / = %

Graded by:

Date:

Co-graded by (not required if Scantron graded):

Date:

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Retention: 6 years Disposition: Instructor, Training Supervisor, and TAC Retain in: Training Records Duane Arnold SRO Exam.doc Rev. 0 WRITTEN EXAMINATION COVERSHEET Training program: Senior Reactor Operator Examination Number/Title: 2002 ILC SRO Written Exam Course/lesson plan Number(s):

50007

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 1 2002 ILC SRO Written Exam 1 Point

1.

Why are the ISVs (Intermediate Stop Valves) designed to close to isolate the MSRs during a Main Turbine trip?

a.

To prevent MSR drain tank flashing caused by the rapid depressurization of the MSRs.

b.

To protect the Main Turbine from debris caused by fast closure of the Turbine Stop Valves.

c.

To protect the Main Turbine against an over speed caused by the stored steam in the MSR and cross around piping.

d.

To prevent excessive thrust loading on the MSR internal components caused by fast closure of the Turbine Stop Valves.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 2 2002 ILC SRO Written Exam 1 Point

2.

A Reactor SCRAM has occurred and has NOT been reset.

The OSS directs you to perform IPOI 5 Reactor Scram and verify all control rods fully inserted.

The Full Core Display shows 4 control rods with their green FULL IN lights OFF.

IAW IPOI 5 Reactor Scram, what other method is allowed to verify all control rods are fully inserted?

a.

Requesting a Rod Log

b.

Check SPDS for ALL RODS IN

c.

Use of Refuel One Rod Selected Permissive

d.

Check the rods are at position 00 on the Four Rod Display

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 3 2002 ILC SRO Written Exam 1 Point

3.

A plant transient has occurred and ALC has been entered.

The following conditions currently exist:



All rods are in



Reactor Pressure has been stabilized at 550 psig



RPV level is +70 inches and lowering at 10 inches/min.



All available high pressure injection sources are injecting at maximum flow



RHR is being used to spray the Torus and Drywell



Drywell pressure is 3 psig and holding steady The OSS orders the panel operator to line up and maximize injection with RHR and Core Spray.

The 1C03 operator verifies the A Core Spray pump is running and MO-2115 Outboard Inject Valve is OPEN.

The operator then attempts to OPEN MO-2117 Inboard Inject Valve to maximize flow but the valve will NOT OPEN.

Which of the following would explain these conditions?

a.

The Core Spray Automatic Initiation signal does NOT exist with these conditions. When RPV level drops to the Core Spray Initiation setpoint the operator will be able to OPEN the valve.

b.

Valve logic prevents simultaneously OPENING both Inboard and Outboard Inject Valve at this time to prevent over pressurizing the low pressure Core Spray piping.

c.

The differential pressure across the valve is too high. The Outboard Inject valve will need to be CLOSED and the Inboard Inject valve cracked off its closed seat. Then both valves can be OPENED.

d.

The A SBDG logic has failed to provide an OPEN permissive to the Core Spray Inject valve logic. The operator should verify the A SBDG is running.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 4 2002 ILC SRO Written Exam 1 Point

4.

The plant was operating at 92% power.

A plant transient occurred requiring a Manual SCRAM.

An electrical ATWS was entered due to failure to SCRAM conditions.

Defeat 15 MSIV and MSL Drain LO-LO-LO Level Isolation Defeat is installed.

Reactor power has stabilized at 4%.

RPV water level is 135 inches and steady.

The Main Turbine is still on line.

At 0910 a steam leak is detected in the Steam Tunnel reading 180OF and increasing at 10OF per minute.

Which of the following will occur if no operator action is taken and the above conditions continue?

a.

At 0912 power will increase due to a rapid rise in RPV pressure.

b.

At 0912 a Group 1 signal will occur. However, power will not be affected due to installation of Defeat 15.

c.

At 0922 the MSIVs will close causing power to increase.

d.

At 0922 the Main Turbine will trip. However, the Bypass Valves will maintain power stable at 4%.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 5 2002 ILC SRO Written Exam 1 Point

5.

A SCRAM occurs from full power.

The following actions occur:



All RHR (LPCI) and Core Spray Pumps START



Primary Containment Group 1 and Group 7 valves CLOSE



The A and B SBDGs START



The ADS Timers START Which one of the following would account for this set of indications?

a.

Loss of 1A3 and 1A4 essential busses.

b.

Drywell Pressure has reached its Hi pressure trip setpoint 2 psig.

c.

RPV water level has reached its LO-LO level trip setpoint 119.5 inches.

d.

RPV water level has reached its LO-LO-LO level trip setpoint 64 inches.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 6 2002 ILC SRO Written Exam 1 Point

6.

Review the indication given in the Support Material Booklet The plant was at power.

10 minutes ago annunciator 1C04C D-3 Drywell Equip Drain Sump Hi Temp alarmed followed shortly by 1C04C C-3 Drywell Equip Drain Sump Hi Leakage.

The ARP automatic actions occurred properly with 1P37B B DW Equipment Drain Pump RUNNING recirculation through the 1E-34 DW Equipment Drain Sump HX".

The STA reports Drywell pressure rising.

Drywell pressure has reached 3.5 psig and is slowly rising.

Annunciator 1C04C B-1 Drywell Equipment Drain Sump HI-HI Level is in alarm.

At this point you observe the Drywell Drain system indications shown in the support material booklet.

Which action is correct for the current plant conditions?

(Assume indicated annunciators are still in alarm)

a.

Take HS for CV-3728 and CV-3729 Drywell Equipment Drain Sump Isolation Valves to CLOSED and check that both 1P37A and 1P37B AUTOMATICALLY STOP.

b.

Take HS for 1P37A and 1P37B to STOP and check CV-3728 and CV-3729 Drywell Equipment Drain Sump Isolation Valves AUTOMATICALLY CLOSE.

c.

Take HS for CV-3728 and CV-3729 Drywell Equipment Drain Sump Isolation Valves to CLOSED and check that 1P37A and 1P37B remain RUNNING.

d.

Take HS for CV-3728 and CV-3729 Drywell Equipment Drain Sump Isolation Valves to CLOSED and check that 1P37A or 1P37B remains RUNNING.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 7 2002 ILC SRO Written Exam 1 Point

7.

The plant is at full power.

You are the 1C05 operator and notice the following indications:

 Reactor power on the APRMs is noted to be slowly rising.

 Main Generator load is rising.

 Final Feedwater temperature is lowering.

 Condenser backpressure has risen.

Which of the following would account for this set of indications?

a.

CV-1139 Feedwater Heater 1E-5A Dump to Condenser is OPEN.

b.

CV-1158A HP Turbine Extraction Steam Outlet to 1E-6A is OPEN.

c.

MO-1546 LP Feedwater Heater Bypass Isolation Valve is CLOSED.

d.

CV-1237 High Pressure Turbine Extraction Steam Bypass Valve is CLOSED.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 8 2002 ILC SRO Written Exam 1 Point

8.

An electrical ATWS has occurred with reactor power remaining at 7%.

The 1C05 operator is directed to manually drive control rods.

1) Should the Rod Worth Minimizer be PLACED IN BYPASS or should it REMAIN IN OPERATE?

AND

2) What is the CORRECT reason for the answer to part 1 of this question?
a.
1) PLACED IN BYPASS
2) To disable possible Select Blocks.
b.
1) PLACED IN BYPASS
2) To disable possible Insert Blocks.
c.
1) REMAIN IN OPERATE
2) To enforce insertion of the highest worth rods FIRST.
d.
1) REMAIN IN OPERATE
2) To transmit rod positions to the Plant Process Computer.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 9 2002 ILC SRO Written Exam 1 Point

9.

As primary containment pressure exceeds 55 psig, which of the below correctly describes the operational implications of this pressure?

a.

The containment vent valves will not open due to high delta pressure.

b.

The HPCI malfunctions due to high backpressure.

c.

The SRVs will not remain open.

d.

Containment failure.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 10 2002 ILC SRO Written Exam 1 Point

10. The plant is at full power when annunciator 1C07A B-4 EHC Fluid reservoir 1T-33 LO Level is received.

The in-plant operator reports an unisolable EHC leak.

The OSS directs Reactor SCRAM and IPOI 5 actions to be carried out.

EOP 1 is entered on LO RPV water level after the SCRAM.

The OSS then directs securing both EHC pumps.

Which of the following is correct concerning Bypass valve operation for this event and subsequent Reactor pressure control?

a.

Bypass Valve operation will NOT be available for long term RPV pressure control under these conditions. ADS/SRVs, HPCI, or RCIC can be used for RPV pressure control.

b.

The Bypass Valves will NOT control with Pressure Set. However, the Bypass Valve Opening Jack will still function.

c.

The installed Bypass Valve accumulators provide 30 minutes of Bypass Valve operation. At this point decay heat will be within the capacity of the MSL Drain Valves.

d.

The Bypass Valves will NOT be available for RPV pressure control. Use Chest Warming to control RPV pressure until decay heat is within the capacity of the MSL Drains.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 11 2002 ILC SRO Written Exam 1 Point

11. The Plant is at 90% power.

ATWS conditions have occurred.

Which of the following is correct with regard to automatic initiation of ATWS ARI/RPT and what does this accomplish?

Actions are automatically initiated

a.

at 119.5 inches RPV Water Level which rapidly reduces power due to a rapid increase in voids.

b.

at 1055 psig RPV Pressure which OPENS (vents to atmosphere) the ARI solenoid valves, depressurizing the Scram Air Header.

c.

at <90% OPEN on the Turbine Stop Valves which rapidly reduces power due to a rapid increase in voids.

d.

on a Fast Closure Signal to the Turbine Control Valves which OPENS (vents to atmosphere) the ARI solenoid valves, depressurizing the Scram Air Header.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 12 2002 ILC SRO Written Exam 1 Point

12. The plant is at 40% power.

Control Rod 14-31 is at position 12.

Which of the following components is designed to prevent OUTWARD rod motion if the insert line were to rupture on the CRD Mechanism to Control Rod 14-31?

a.

Collet assembly.

b.

Coupling spud.

c.

Drive piston.

d.

Stop piston.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 13 2002 ILC SRO Written Exam 1 Point

13. The plant has suffered a major event and SAG entry was required.

Hydrogen concentrations in the Drywell have reached 5.1%.

You are directed to perform SEP 303.3 CAD Purge for H2 Control In SAGs The following plant conditions currently exist:



B RHR Loop is being used for Drywell and Torus Sprays.



MO-2010 RHR Loops A/B Cross-Tie Header Isolation Valve is CLOSED.



A RHR Loop is in Torus Cooling.



Drywell Pressure is 25 psig and steady.



MO-2000 RHR Loop A Inboard Drywell Spray Valve is bound CLOSED.



Torus Level is 11.2 ft and stable.

Can N2 from the CAD system be purged into the containment with the current plant condition?

If YES, where can it be injected?

If NO, why can it not be injected?

a.

YES. It can be injected into the A RHR Torus Spray Header.

b.

YES. It can be injected into the A RHR Drywell Spray Header.

c.

NO. MO-2000 must be OPENED.

d.

NO. Drywell pressure above the High Drywell pressure interlock.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 14 2002 ILC SRO Written Exam 1 Point

14. Which of the following is designed to initiate AUTOMATIC actions to protect the Main Turbine from over heating of the last stage buckets?

(Assume NO operator actions)

a.

High Condenser Backpressure, 7.5 Hg absolute.

b.

MSR high level, 3 inches below the MSR Shell.

c.

HI-HI exhaust hood temperature, 225OF

d.

Main Turbine HI-HI Vibration, 10 mils.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 15 2002 ILC SRO Written Exam 1 Point

15. The plant was at full power when a Station Blackout occurred.

Assume the OSS directed you to perform each of the following EOP actions.

Which one of the following actions can be accomplished AND will perform the system function directed by the OSS?

(Assume manual operation of MOTOR OPERATED valves is performed when required)

a.

Install Defeat 16 Containment Atmosphere Monitoring Sample Line Isolation Defeat to re-establish H2 sampling of the Drywell.

b.

Lower Torus water level by draining the Torus to Radwaste per OI 149 RHR System section 12.0 Draining to Radwaste.

c.

Install Defeat 4 Drywell Cooler Isolation Defeat to reduce Drywell air temperature.

d.

Install AIP 404 Injection with Fire Water then initiate Torus and Drywell sprays to reduce Torus and Drywell pressure.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 16 2002 ILC SRO Written Exam 1 Point

16. A plant transient occurred from full power.

A SCRAM was successfully inserted.

RPV injection is secured with the exception of CRD.

The MSIVs are open.

Reactor Water level is 280 inches on the Floodup Level indicator and slowly rising.

Reactor pressure is 145 psig and slowly raising.

Which of the following is required for the CURRENT plant conditions?

a.

Initiate Shutdown Cooling and drain to Radwaste.

b.

Manually open SRVs as needed to provide a drain path.

c.

Reduce Load Set until the Main Steam Bypass Valves open.

d.

Close the MSIVs until RPV level is restored and MSLs drained.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 17 2002 ILC SRO Written Exam 1 Point

17. The plant is at full power.

Drywell temperature is 130OF and rising due to a Well Water problem.

The OSS directs you to, Vent the Drywell IAW OI 573 Containment Atmosphere Control System section 6.1 Normal Containment Venting.

B SBGT is started and Containment Rad levels are normal.

You have lined up and are venting the Drywell and maintaining Drywell pressure as directed.

Several annunciator alarm including 1C07A A-11 HVAC Panel 1C-23 Trouble. The BOP operator determines that RIM-7606A A RB Vent Shaft Rad Monitor has failed.

Which one of the following is correct concerning the venting of the Drywell?

Drywell venting

a.

is NOT effected because RIM-7606A is not associated with B SBGT.

b.

can NOT be re-established with either a Group 3A or B Isolation signal present.

c.

can be re-established once RIM-7606A input to Group 3A logic is bypassed and the Containment Vent Path is selected to Drywell on 1C05.

d.

can continue but only (the small valve) CV-4310 Inboard DW Vent CV-4302 Bypass Valve is available with the Group 3A isolation signal present.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 18 2002 ILC SRO Written Exam 1 Point

18. The plant is at full power.

One loop of RHR is in the Torus Cooling mode with full RHR and RHRSW flow.

At this point a Safety Relief Valve (SRV) fails FULL OPEN.

The other loop of RHR is quickly placed in Torus Cooling and flows maximized.

Which of the following CORRECTLY describes the expected response of Torus water temperature if the SRV CAN NOT be closed?

a.

Torus water temperature will still be LOWERING with only one loop of Torus Cooling on and LOWER EVEN FASTER when the second loop of Torus Cooling is placed in service.

b.

Torus water temperature will STABILIZE with only one loop of Torus Cooling on and BEGIN TO LOWER when the second loop of Torus Cooling is placed in service.

c.

Torus water temperature will RISE with only one loop of Torus Cooling on and BEGIN TO LOWER when the second loop of Torus Cooling is placed in service.

d.

Torus water temperature will RISE with only one loop of Torus Cooling on and CONTINUE TO RISE when the second loop of Torus Cooling is placed in service.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 19 2002 ILC SRO Written Exam 1 Point

19. AOP 915 Shutdown Outside Control Room has been entered and the transfer has been completed.

Which of the following is correct?

a.

Div I RHR and Core Spray logics are disabled. LLS and ADS are disabled.

b.

Div I RHR and Core Spray logics are disabled. ADS and Group 1 are disabled.

c.

Div II RHR and Core Spray logics are disabled. LLS and ADS are disabled.

d.

Div II RHR and Core Spray logics are disabled. LLS and Group 1 are disabled.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 20 2002 ILC SRO Written Exam 1 Point

20. Review the panel indications given in the Support Material Booklet The plant was at power.

A transient has occurred requiring entry into EOP 4.

An unmonitored Off-site release is in progress.

Which one of the following systems has failed to isolate and what is the source of the steam leak?

(Assume in each case the indicated system is the only failure and all other systems have responded correctly)

a.

HPCI steam leak in Radwaste.

b.

RWCU steam leak in Steam Tunnel.

c.

MSL drain steam leak in Turbine Building.

d.

RCIC steam leak at Barometric Condenser.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 21 2002 ILC SRO Written Exam 1 Point

21. The plant is at Full power.

A partial loss of GSW occurs.

Which of the following components has exceeded an AUTOMATIC trip point and is required to be tripped manually?

a.

A RFP with oil temperature at 245OF.

b.

The Main Generator with Isolation Bus Temperature at 185OF.

c.

The A Recirc MG Set with oil temperature at 220OF.

d.

Both A and B EHC pumps with EHC Tank temperature at 140OF.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 22 2002 ILC SRO Written Exam 1 Point

22. A complete loss of the service and instrument air systems occurs while at full power.

Operators are trying to restart a compressor as air header pressure lowers, but they may be required to SCRAM the reactor.

Which one of the following is a potential effect on the Control Rod Drive (CRD) Hydraulic System?

a.

The scram discharge volume may fail to isolate when the scram occurs.

b.

Cooling flow could be lost to the control rod drive mechanisms before the scram occurs.

c.

The running CRD pump could trip due to operating at no flow conditions.

d.

The Backup scram valves could fail to vent the Scram Air Header when the scram occurs.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 23 2002 ILC SRO Written Exam 1 Point

23. Review the CIMS panel indications given in the Support Material Booklet The plant is currently at 90% power.

I&C Technicians are performing a TIF on a problem in 1C43 Division 1 Core Spray Vertical Board.

A CIMS alarm is received.

Which of the following is correct concerning the indications provided?

a.

The B Drywell Well Water isolation valves have isolated. The A Drywell Well Water isolation valves have not isolated. If no operator actions are taken the Reactor will scram.

b.

Both A and B Drywell Well Water isolation valves have isolated. If no operator actions are taken the Reactor will scram.

c.

A signal is present for the Well Water Isolation but not all valves have isolated. If no operator actions are taken the reactor may scram depending on the current valve positions.

d.

A signal is present for the Well Water Isolation but the signal has an override in effect. A Reactor scram will not occur.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 24 2002 ILC SRO Written Exam 1 Point

24. Given the following Conditions:

The plant is operating at full power.

The A CRD pump Tripped.

The B CRD pump has NOT been started.

Which one of the following statements describes the effect the loss of CRD pumps has on the plant?

a.

The Control Rods will NOT fully SCRAM with RPV pressure alone due to pressure equalization across the drive piston.

b.

The Control Rods can still be SCRAMMED, but the insertion time will be significantly longer.

c.

Multiple Control Rods will begin to drift if a pump is NOT returned to service within 15 minutes.

d.

Control Rod Drive mechanism temperatures will begin to rise.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 25 2002 ILC SRO Written Exam 1 Point

25. Review the indication given in the Support Material Booklet The plant is currently at 45% power.

An SRV is leaking by to the Torus.

Which of the following is correct concerning the Torus Temperature indicator on 1C03?

(Assume the ONLY parameter changing is Torus Temperature)

a.

The indicator is receiving a SINGLE input signal. Before the RED band is reached an EOP 1 entry is required.

b.

The indicator is receiving a SINGLE input signal. Before the YELLOW band is reached an EOP 1 entry is required.

c.

The indicator is receiving MULTIPLE input signals. Before the RED band is reached an EOP 1 entry is required.

d.

The indicator is receiving MULTIPLE input signals. Before the YELLOW band is reached an EOP 1 entry is required.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 26 2002 ILC SRO Written Exam 1 Point

26. A loss of Drywell cooling occurred, causing the crew to SCRAM (successfully) from Full power.

When Average Drywell Air temperature could NOT be restored and maintained <280F the crew Emergency Depressurized the RPV.

The OSS has performed a crew brief to inform the crew that the Sat Curve has been entered.

(EOP-2, Graph 1)

The following applicable parameters are at these stable values:



Both Recirc pumps are tripped.



Indicated NR GEMAC RPV level 190



Indicated WR Yarway RPV level 200



Indicated WR GEMAC (Floodup) RPV level 200



Indicated Fuel Zone RPV level 190

What value for RPV water level, if any, should be used for EOP decision-making purposes?

a.

167

b.

190

c.

200

d.

None, all RPV level indicators should be considered unreliable.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 27 2002 ILC SRO Written Exam 1 Point

27. Review the indication given in the Support Material Booklet EOP 2 directs entry into EOP 1 if Torus Water Level CANNOT be maintained BELOW 13.5 ft.

Review the attached picture.

At what point does Torus water level reach the level that requires EOP 1 entry from EOP 2?

a.

A

b.

B

c.

C

d.

D

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 28 2002 ILC SRO Written Exam 1 Point

28. Which of the following curves, if followed, will prevent system damage due to air entrainment?
a.

ECCS Vortex Limit

b.

RHR NPSH Limit

c.

Heat Capacity Limit

d.

Core Spray NPSH Limit

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 29 2002 ILC SRO Written Exam 1 Point

29. The plant is at full power.

During transfer of RWCU resin, a pipe break released resin to the RB 2nd Floor North area outside the RWCU Phase Separator Room.

EOP 3 was entered on Radiation Levels in ONE area above MAX SAFE.

No other EOP 3 entry conditions exist.

The resin has been contained in this area.

The following High Radiation Areas have been posted due to this event:

 RB 1st Floor Northwest

 RB 2nd Floor North and SBGT Room

 RB 3rd Floor Northwest

 RB North Stairwell below RB 4th Floor

 ALL other area radiation levels are normal Which alarm is consistent with this event?

a.

1C03A D-9 RBCCW RM-4820 HI RAD

b.

1C04C A-1 RADWASTE EFFLUENT RIS-3972 HI RAD

c.

1C04B B-6 NEW FUEL STORAGE AREA ARM HI RAD

d.

1C04B D-7 RHRSW AND ESW EFFLUENT RM-1997 OR RM-4268 HI RAD

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 30 2002 ILC SRO Written Exam 1 Point

30. Which of the following requires operator verification of Secondary Containment Isolation and entry into EOP 3?
a.

RB Vent Shaft Rad Monitor Rad levels reading 10 mR/hr.

b.

Offgas Vent Pipe above the HI-HI Rad Trip setpoint.

c.

Fuel Pool Exhaust Rad levels reading 10 mR/hr.

d.

MSL HI-HI Rad at 500 mR/hr.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 31 2002 ILC SRO Written Exam 1 Point

31. EOP 4 Radioactive Release Control requires Emergency Depressurization before certain conditions are reached.

What purpose does Emergency Depressurization achieve AS IT RELATES TO EOP 4?

a.

This establishes or maintains adequate core cooling.

b.

This places the primary system in a low energy condition and reduces the driving head to the leak.

c.

Reduces the energy in the RPV before reaching conditions where the primary containment will not accommodate an SRV opening.

d.

This places the RPV in a low energy condition before reaching conditions where a loss of coolant accident could not be adequately contained in the primary containment.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 32 2002 ILC SRO Written Exam 1 Point

32. A fire occurs in the Cable Spreading Room.

(Assume the Fire Protection System is lined up for AUTOMATIC ACTUATION and Cable Spreading Room access is restricted)

The installed fire protection system automatically actuates.

The room must be entered to determine if the fire has been extinguished.

(1) What is the classification of the fire that is expected in this area?

AND (2) What safety hazard, from the automatic system actuation, should be considered prior to operators entering the Cable Spreading Room?

(1)

(2)

a.

Class B Electrical Shock from water spray

b.

Class C Electrical Shock from water spray

c.

Class B Suffocation from oxygen depletion due to the discharge of CO2 in the area

d.

Class C Suffocation from oxygen depletion due to the discharge of CO2 in the area

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 33 2002 ILC SRO Written Exam 1 Point

33. SRO ONLY The plant is shutdown.

The B side of Shutdown Cooling (SDC) is in service with B RHR and B RHRSW pumps running.

MO1940 RHR HX 1E-201B Bypass and MO1939 RHR HX 1E-201B Inlet Throttle valves are THROTTLED in mid position.

MO1904 and MO1905 RHR Loop B Inject Isolation Valves are OPEN.

MO1908 and MO1909 RHR Shutdown Cooling Suction Isolation Valves are OPEN.

Annunciator 1C03B B-4 RHR SHUTDOWN COOLING SUCTION HEADER HI PRESSURE alarms and SDC Header pressure is reported to be 105 psig and rising at 2 psig/min.

You direct the 1C03 operator to raise the cooldown rate.

Several minutes later the 1C03 operator reports RHR suction header pressure is 145 psig and MO1940 is not responding.

(No other plant conditions have changed and no alarms have occurred)

Which of the following is the correct action?

a. Direct the 1C03 operator to secure SDC per OI 149 Residual Heat Removal System. Enter AOP 302.2 Loss of Alarm Power.
b. Direct the 1C03 operator to throttle OPEN more on MO1939 and start the D RHR pump if necessary. Enter T.S. for LPCI.
c. Direct the 1C03 operator to CLOSE MO1905, Trip the B RHR pump and CLOSE MO1908 and MO1909. Enter AOP 149 Loss of Decay Heat Removal.
d. Direct the 1C03 operator to CLOSE MO1939, Start the D RHR pump and then re-establish SDC flow. Enter AOP 149 Loss of Decay Heat Removal until SDC is re-established.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 34 2002 ILC SRO Written Exam 1 Point

34. Refueling operations are in progress with the Mode Switch in REFUEL.

Which of the following allows the withdrawal of a control rod AND ensures the reactor will remain shutdown?

a. The One-Rod permissive interlock and following the fuel moving plan during fuel moving.
b. The RSCS Group Selector switch selected to the correct sequence and adequate shutdown margin designed into the core
c. Refueling Rod Block Interlocks and the proper rod withdrawal sequence loaded into the RWM.
d. The RSCS Mode Selector Switch placed in WITHDRAW and following the fuel moving plan during fuel moving.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 35 2002 ILC SRO Written Exam 1 Point

35. Review the indication given in the Support Material Booklet The plant is at full power.

Annunciator 1C04B B-4 Steam Leak Detection Ambient HI Temp was received.

RCIC has failed to isolate and temperatures were noted to be rising slowly.

The operator manipulates the Steam Leak Detection panel as Shown.

Which of the following is correct concerning the RCIC Room?

a.

Room Differential Temperature is 50OF.

b.

Room Differential Temperature is >50OF.

c.

Room Ambient Temperature is 155OF.

d.

Room Ambient Temperature is >175OF.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 36 2002 ILC SRO Written Exam 1 Point

36. Main Plant Exhaust Plenum pressure is rising.

Which of the following will AUTOMATICALLY initiate to provide the indicated protective function?

a. The Main Plant Exhaust Fans sequentially SHIFT to High Speed to prevent collapsing the Main Plant Exhaust Plenum.
b. The Reactor Building Exhaust Fans START to prevent Refuel Floor blow out panels from lifting.
c. The Reactor Building Supply fans TRIP to prevent over pressurizing Secondary Containment.
d. SBGT STARTS to draw at least a -.25 inch WG in the Reactor building.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 37 2002 ILC SRO Written Exam 1 Point

37. The plant has SCRAMMED from full power.

While stabilizing the plant, an operator observes the following indications:



The running CRD pump current is above normal running amps.



CRD Cooling Water flow is DOWNSCALE.

Select the answer that CORRECTLY explains these indications and identifies the appropriate operator response.

a. The flow control station has failed; action must be taken as soon as possible to protect the CRDMs.
b. The in service CRD suction filter is clogged; the standby filter must be placed in service as soon as possible.
c. CRD pump flow is being diverted through the Scram Inlet valves to the CRDMs and the reactor; no further actions are necessary.
d. The running CRD pump is air bound and must be tripped as soon as possible.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 38 2002 ILC SRO Written Exam 1 Point

38. SRO ONLY An unisolable leak on the RWCU system has caused radiation levels to increase in the Reactor Building.

The BOP operator reports the "RWCU PUMP AREA" is above Maximum Safe for BOTH Temperature and Radiation levels.

Multiple areas indicate radiation readings above Maximum Normal.

Which of the below correctly lists the required actions and the basis for those actions?

a. Commence a normal reactor shutdown, due to multiple areas above the Maximum Normal Radiation and one area being greater than Maximum Safe Temperature.
b. Insert a manual SCRAM, due to one area being greater than Maximum Safe and a primary system discharging into the secondary containment.
c. Perform an Emergency Depressurization, based on the potential of exceeding Maximum Safe Radiation in two areas.
d. Perform an Emergency Depressurization, based on exceeding two Maximum Safe conditions.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 39 2002 ILC SRO Written Exam 1 Point

39. SRO ONLY The plant is at power.

The Rod Select Power Switch S1 is to be immediately replaced in response to a GE SIL for problems with CR2940 type switches.

It is determined that power to the switch will have to be tagged out and de-energized for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

You are the OSS and you are reviewing the work prior to release.

1) Which person(s) is/are the minimum level of approval required to approve this work prior to the tagout being hung AND
2) what procedure directs this approval?
a. 1) Plant Manager
2) OI 856.1 Reactor Manual Control System
b. 1) Plant Manager
2) ACP 1410.4 Operating Orders
c. 1) Operations Manager and Reactor Engineer
2) OI 856.1 Reactor Manual Control System
d. 1) Operations Manager and Reactor Engineer
2) ACP 1410.4 Operating Orders

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 40 2002 ILC SRO Written Exam 1 Point

40. Both Reactor Recirculation pumps were running at 70% speed when an internal component failure in the B MG SET SPEED CONTROL caused the controller speed demand output signal to instantaneously fail to the MAXIMUM value.

Which of the following CORRECTLY describes the expected affect of this failure on core flow?

Core flow will rise until

a. the B Recirc Scoop Tube Positioner reaches its ELECTRICAL STOP.
b. the B Recirc Scoop Tube Positioner reaches its MECHANICAL STOP.
c. a B Recirc Scoop Tube Positioner LOCK-UP occurs due to high Milliamp output signal from the Controller.
d. a B Recirc Scoop Tube Positioner LOCK-UP occurs due to high deviation between the Controller speed demand and the Positioner position.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 41 2002 ILC SRO Written Exam 1 Point

41. The plant is being shut down.

All Control Rods have been inserted.

RPV pressure is 220 psig.

RHR is in Standby/Readiness Condition per OI 149 RHR System with NO pumps running.

The B Recirculation pump is RUNNING.

The A Recirculation pump has been SECURED.

The A Recirculation pump Suction, Discharge, and Discharge Bypass Valves are OPEN.

Which of the following will occur if RPV water level were to drop to 119.5?

(The DEFAULT loop is selected for injection and Drywell pressure is NOT rising)

a. The A Recirc Loop Discharge and Discharge Bypass valves will receive a CLOSE signal.
b. The A RHR Loop LPCI Inboard and Outboard Injection valves will receive a CLOSE signal that is sealed in for 10 minutes from the time that a loop is selected.
c. The B Recirc pump will trip after the Discharge and Discharge Bypass valves CLOSE.
d. The B RHR Loop Inboard LPCI Inject valve will OPEN and RHR will immediately inject into the RPV.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 42 2002 ILC SRO Written Exam 1 Point

42. SRO ONLY The plant is at full power.

Review the following time line.

2005: The RO reports Drywell Identified leakage is 27.3 gpm and Unidentified leakage is 0.5 gpm.

2009: 1C05B B-2 Primary Containment HI/LO Pressure alarms on high pressure.

2014: The OSS directs a SCRAM that is successful.

2015: 1C05B A-1 Primary Containment Hi Pressure Trip due to a steam leak in the Drywell.

2020: Torus and Drywell Sprays are direct, but are unsuccessful. Drywell pressure is rising.

2045: RPV level is at +10 inches and lowering at 1 inch every 5 minutes with all available injection sources injecting.

2046: Emergency Depressurization is directed. When the first ADS/SRV is opened Torus pressure increases rapidly to 58 psig.

2050: Containment venting per SEP 301.1 Torus Vent Via SBGT is directed and successful.

Excluding EC/OSM Judgement, at what time does plant conditions FIRST meet the requirement(s) to sound the plant Evacuation Alarm?

a. 2005
b. 2015
c. 2045
d. 2050

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 43 2002 ILC SRO Written Exam 1 Point

43. Following a full Group I Isolation at full power, HPCI received an auto initiation signal on RPV low level.

During the Group I Isolation, the HPCI pump flow signal was lost to the flow controller, sensing a constant ZERO gpm flow signal.

Which of the following describes the HPCI system response if NO operator action is taken?

The HPCI turbine will

a. remain at minimum speed.
b. trip on high RPV water level.
c. trip as soon as the signal is lost.
d. trip on overspeed and remain shutdown.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 44 2002 ILC SRO Written Exam 1 Point

44. The plant is at full power.

Which of the following Core Spray pressure annunciators/indications describe the operators indication that a leak has occurred in the Core Spray piping BETWEEN the Reactor Vessel and Core Shroud?

a.

Core Spray Sparger HI  P (3.6 psig increasing)

b.

Core Spray Sparger LO  P (2.46 psid decreasing)

c.

Core Spray Discharge line low pressure (47.5 psig decreasing)

d.

Core Spray Discharge line high pressure (100 psig increasing)

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 45 2002 ILC SRO Written Exam 1 Point

45. A transient has occurred while at power, which has resulted in a Bus 1A3 lockout followed by a hydraulic ATWS.

The 1C05 operator initiates Standby Liquid Control (SBLC) as directed.

Which of the following CORRECTLY describes the expected condition of the SBLC Squib valves based on their respective power supplies?

a.

Both will have actuated; they are powered from respective divisions of 125 VDC.

b.

Both will have actuated; they are powered from Uninterruptible AC.

c.

Only one will have actuated; it is powered from B RPS.

d.

Only one will have actuated; it is powered from its associated pump breaker on 1B44.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 46 2002 ILC SRO Written Exam 1 Point

46. A turbine trip from full power has caused a reactor scram.

RPV level lowered to 110 during the initial transient but has been restored to the normal operating band for two minutes.

The scram has NOT been reset?

Select the answer that correctly describes the status of the RPS Backup Scram valves under these plant conditions.

Both Backup Scram valves should be...

a.

energized and OPEN (venting)

b.

energized and CLOSED (not venting)

c.

deenergized and OPEN (venting)

d.

deenergized and CLOSED (not venting)

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 47 2002 ILC SRO Written Exam 1 Point

47. You are directed by OI 878.2 Intermediate Range Neutron Monitoring System to closely monitor IRMs when switching between Range 6 and Range 7.

What is the reason for this direction?

a.

The affects of Power Range Gammas are starting to overcome the affects of Decay Gammas and will cause power to show a faster rate of rise.

b.

The SRM Rod Blocks are bypassed at this point and IRM spiking has occurred due to noise when the SRM circuitry bypasses the SRMs.

c.

The Mean Square Analog Unit is switched into the circuit at this point and starts applying the Campbelling calculations to the IRM output.

d.

The IRMs shift between Low and High Frequency Amplifiers at this point and could affect the IRM output signal.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 48 2002 ILC SRO Written Exam 1 Point

48. Review the indication given in the Support Material Booklet SRO ONLY The plant was at full power when a transient occurred that required insertion of a SCRAM.

The plant experienced an electrical ATWS.

Control Rods were successfully inserted with the individual test switches per the RIPs.

Plant conditions were stabilized.

Alarm 1C05A D-5 SRM Downscale is received.

The SCRAM has not been reset.

As OSS what direction should you give based on the indications given?

a.

Direct the STA to write an AR for the C SRM downscale alarm.

b.

Direct the BOP operator to perform AOP 375 Loss of 24 VDC Power

c.

Direct the 1C05 operator to complete the IPOI 5 SCRAM Immediate Actions.

d.

Direct the RO to have the Second Assistant check the status of the SRM Drive Motor relays.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 49 2002 ILC SRO Written Exam 1 Point

49. The plant is at 85% power.

1C05A D-2 APRM DOWNSCALE annunciator alarms.

The A APRM indicates a downscale condition.

When does the APRM alarm occur AND with NO other plant changes what other annunciator will alarm?

a.

Alarm at 12% and 1C05B B-6 RBM UPSCALE OR INOP

b.

Alarm at 5% and 1C05B B-6 RBM UPSCALE OR INOP

c.

Alarm at 12% and 1C05B A-6 ROD OUT BLOCK

d.

Alarm at 5% and 1C05B A-6 ROD OUT BLOCK

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 50 2002 ILC SRO Written Exam 1 Point

50. SRO ONLY The plant was at full power.

A SCRAM was manually inserted due to the loss of 120VAC Uninterruptible power.

RPV Level is being controlled at 160 inches.

SBLC was NOT initiated.

The RPS Trip Test Switches were placed in the TRIP position per RIP 101.1 RPS Trip Test Switches.

The 1C05 operator reports IRMs are inserted and are reading 35 on range 6 and lowering.

Which of the following is correct for the given plant conditions?

a.

Exit ATWS and enter EOP 1.

b.

Remove RIP 101.1 then exit ATWS and enter EOP 1.

c.

Exit the Q flowpath of ATWS and enter IPOI 5 SCRAM.

d.

Remain in all legs of ATWS and continue inserting the RIPs.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 51 2002 ILC SRO Written Exam 1 Point

51. SRO ONLY A normal plant Shutdown from full power operations is in progress.

The GEMAC Reference Leg Backfill System has been out of service for 3 weeks.

RPV level is 190 inches and stable.

(1) Which of the following is the correct directions for these plant conditions and (2) which procedure gives direction if NOTCHING is observed?

a.

(1) When RPV pressure reaches 500 psig direct the operating crew NOT to use the Yarway instruments on 1C05 for level indication.

(2) OI 880 Non-Nuclear Instrumentation System Section J Operation of the GEMAC Reactor Level Instruments Reference Leg Backfill System.

b.

(1) When RPV pressure reaches 500 psig direct the operating crew NOT to use the Yarway instruments on 1C05 for level indication.

(2) IPOI 4 Shutdown.

c.

(1) Direct enhanced RPV Level monitoring during the Shutdown.

(2) OI 880 Non-Nuclear Instrumentation System Section J Operation of the GEMAC Reactor Level Instruments Reference Leg Backfill System.

d.

(1) Direct enhanced RPV Level monitoring during the Shutdown.

(2) IPOI 4 Shutdown.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 52 2002 ILC SRO Written Exam 1 Point

52. The plant is at 75% power.

The RCIC turbine has been started CST to CST using the flow-indicating controller.

RCIC is at 3000 RPM and stable.

Other plant conditions are normal with the exception of those systems lined up to support the RCIC testing.

Annunciator 1C04C C-9 RCIC INVERTER POWER FAILURE Alarms and RCIC Inverter failure is confirmed.

Which of the following is correct concerning the RCIC turbine?

RCIC will

a.

remain running at 3000 rpm.

b.

tripped on electrical overspeed.

c.

tripped on mechanical overspeed.

d.

be running at idle speed (approx. 1000 rpm).

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 53 2002 ILC SRO Written Exam 1 Point

53. Review the indication given in the Support Material Booklet The Plant was at full power.

A loss-of-coolant accident has occurred resulting in a successful reactor scram.

RPV water level lowered to 110 inches before the trend was reversed.

A transient has occurred involving the RCIC system.

The only operator action taken with RCIC was to cycle the handswitch for MO-2405, RCIC Turbine Stop Valve, to the fully CLOSED position and then to hold it in the OPEN position for three seconds.

What is the status of RCIC based on these indications?

a.

A RCIC Auto Isolation trip has occurred.

The RCIC Turbine trip is RESET.

b.

A RCIC High RPV Level trip has occurred.

The RCIC Turbine trip is RESET.

c.

A RCIC Electrical Overspeed trip has occurred.

The RCIC Turbine trip is NOT RESET.

d.

A RCIC Mechanical Overspeed trip has occurred.

The RCIC Turbine trip is NOT RESET.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 54 2002 ILC SRO Written Exam 1 Point

54. The plant was operating at power.

A transient occurred, a SCRAM was successfully inserted, and the MSIVs were closed.

RPV level is 190 inches and being controlled in Auto by the Feedwater Level Control (FWLC)

System.

SRVs are being used to manually control pressure between 800 and 1000 psig.

The 1C03 operator reports he is opening an SRV to reduce RPV pressure.

Which of the following would be the FIRST expected plant response in regards to cycling open the SRV?

a.

An RPV High Level alarm due to void increase.

b.

An RPV High Level alarm due to FWLC System response to increased steam flow.

c.

An RPV Low Level alarm due to void increase.

d.

An RPV Low Level alarm due to increased mass flowrate NOT sensed by the FWLC System.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 55 2002 ILC SRO Written Exam 1 Point

55. Review the indication given in the Support Material Booklet The plant is at full power.

A Group 3B isolation has occurred and verified to be complete.

You are ordered to override CV-4371A and the system responds as indicated in the picture on the following page.

What are the long-term implications of this system response?

a.

All of the SRVs will eventually lose the ability to lift on their safety setpoint.

b.

1/2 of the SRVs will eventually lose the ability to lift on their safety setpoint.

The other 1/2 are NOT effected.

c.

All of the SRVs have lost N2 from outside the Drywell.

d.

1/2 of the SRVs have lost N2 from outside the Drywell.

The other 1/2 are NOT effected.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 56 2002 ILC SRO Written Exam 1 Point

56. Review the indication given in the Support Material Booklet A plant transient has occurred from full power.

Defeat 4 was inserted and verified correct.

Other EOP actions have been taken and some time later, the BOP observes the panel indications shown in the Support Material Booklet.

Which of the following BY ITSELF would account for the indications observed?

a.

Drywell pressure is below 2 psig.

b.

Drywell sprays have been initiated.

c.

Drywell H2 or O2 concentration is >4%.

d.

Drywell temperature is below the over temperature alarm setpoint.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 57 2002 ILC SRO Written Exam 1 Point

57. The plant is at full power and the A RPS bus becomes de-energized.

Which of the following correctly describes the plant response to this event?

a.

Inboard MSIV control power and position indication will be lost.

b.

PCIS Div 1 Groups 1 through 5 (excluding MSIVs) will isolate.

c.

A Scoop Tube Lockup will occur on the A Recirc MG set.

d.

The A SBDG 1G31 will automatically start.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 58 2002 ILC SRO Written Exam 1 Point

58. Review the panel indications given in the Support Material Booklet.

The plant was at full power when a spurious Group 1 inboard isolation occurred.

The following annunciators are currently ALARMING:

 1C03A C-5 SRV/SV Tailpipe HI Pressure or HI Temp

 1C03A D-5 LLS A or B Armed

 1C05A C-4 Reactor Vessel HI Pressure Trip Based on these conditions and the panel indications shown, which of the following is correct?

a.

PSV 4407 has failed to open.

b.

The operator has reset the B LLS logic on 1C03.

c.

The initial LLS pressure reduction is complete and LLS is cycling normally.

d.

The initial pressure reduction by LLS has just started and LLS is functioning normally.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 59 2002 ILC SRO Written Exam 1 Point

59. The plant is currently at 540 MWe.

LOAD SET was inadvertently placed at 550 MWe.

All other Turbine controls are normal.

As Reactor power is raised to full power, which of the following is the correct plant response?

a.

The Turbine Supervisory Panel will sense a load imbalance at 575 MWe and a Turbine trip will occur.

b.

The 100% Load Limit is in effect at this power level which will allow the Turbine to be loaded to full power.

c.

When Turbine load reaches 550 MWE number 1 Bypass Valve will start opening to control turbine inlet pressure.

d.

When Turbine load reaches 550 MWE reactor pressure will continue to increase and an RPS Scram will occur.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 60 2002 ILC SRO Written Exam 1 Point

60. SRO ONLY The plant was operating at power.

A plant transient occurred resulting in fuel damage.

Groups 3 A/B were verified complete.

1C35A C-3 Reactor Building (RB) KAMAN 3, 4, 5, 6, 7 & 8 Hi Rad or Monitor Trouble alarms.

The 1C03 operator reports that the RB KAMANs are above the yellow hi line and shortly after reports they are at the red hi-hi line and still going up.

How would you direct the following fans to be lined up?

1V-EF-1/2/3 1V-SF-22A/B/C 1V-EF-21A/B/C Main Plant Exhaust Fans Turbine Building Supply Fans Turbine Building Exhaust Fans

a.

All Secured All Secured All Secured

b.

All Secured All Secured At Least One Running in Hi Speed

c.

At Least One Running All Secured All Secured

d.

All Secured At Least One Running At Least One Running in Hi Speed

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 61 2002 ILC SRO Written Exam 1 Point

61. The Narrow Range GEMAC level transmitters (LT-4559, 4560, and 4561) are used in the Reactor Water Level Control system.
1) Are these transmitters calibrated HOT or COLD?

And

2) What type of compensation, if any, do they use?
a.
1) COLD
2) Electronic pressure compensation
b.
1) COLD
2) None
c.
1) HOT
2) Temperature compensation
d.
1) HOT
2) None

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 62 2002 ILC SRO Written Exam 1 Point

62. SRO ONLY The plant is at power.

A SBGT is tagged out for charcoal replacement.

1C24B A-5 B SBGT Control Power Failure alarms.

The Second Assistant reports 1D21 Ckt 19 (B SBGT Control Power) has tripped OPEN and looks damaged.

One attempt is made to close 1D21 Ckt 19 and it will NOT close in.

What is the longest the Mode switch can be left in run if plant conditions do not change?

a.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

b.

9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />

c.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />

d.

13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br />

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 63 2002 ILC SRO Written Exam 1 Point

63. Which one of the following conditions would PREVENT the 1G31, A Diesel Generator, from being shutdown using the Engine Mode Selector Switch on Panel 1C93 SBDG 1G31 Control Panel?
a.

The DG automatically started due to bus undervoltage on 1A3.

b.

The DG automatically started due to a 2 psig in the Drywell.

c.

The DG was started by Fast Manual Start from the DG Room.

d.

The DG was manually started from the Control Room.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 64 2002 ILC SRO Written Exam 1 Point

64. SRO ONLY Refueling is in progress.

The Mode switch is in Refuel.

The Refueling Bridge is positioned to move the next fuel bundle from the Core to the Spent Fuel Pool.

The Fuel Bundle is identified and grappled.

The Refuel Floor SRO reports the bundle is being lifted out of the core.

About 5 seconds later 1C05B A-6 Rod Out Block alarms.

Which of the following is correct for these indications?

a.

Cycle Rod select power OFF the ON to clear the Rod Block.

b.

Suspend fuel moving immediately due to the failure of a refueling interlock.

c.

Indications are normal the time delay is expected due to the Rod Block time delay.

d.

Inform the Refuel Floor SRO of the annunciator because this will prevent bridge travel.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 65 2002 ILC SRO Written Exam 1 Point

65. A Group 1 isolation and ATWS have occurred from full power.



Reactor power was 15% after the Recirc pumps were tripped.



LLS is controlling RPV pressure.



RPV injection was terminated and prevented for Level/Power Control.

As the 1C05 operator, you CLOSED the Feed Reg Valves and are monitoring critical parameters.

You report the following parameters to the OSS:



RPV level is at 150.



Reactor power is at 2%.

At this point the OSS directs you to reestablish injection with feedwater.

Is this direction correct? (YES or NO)

If YES, identify the reason it is correct.

If NO, identify the additional considerations necessary to reestablish injection.

a.

YES Injection may be reestablished when power lowers to <5%. There is no restriction on RPV level.

b.

YES Injection may be reestablished when power lowers to <5% and RPV level is <158.

c.

NO Injection must remain terminated until RPV level lowers to less than +119.5.

d.

NO Injection must remain terminated until RPV level lowers to less than +87.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 66 2002 ILC SRO Written Exam 1 Point

66. A startup is in progress.

Control Rod 18-15 is being notched out.

Position indication for position 18 has been lost.

The RWM-OD (Operator Display) was taken to BYPASS.

Rod 18-15 was driven IN to position 16, IAW the pull sheet, and position 16 was verified operable.

The RWM-OD was taken to OPERATE.

Rod 18-15 is again withdrawn to position 18.

Which of the following is correct AND will allow rod withdrawal of Control Rod 18-15 to position 48 to continue?

a.

A RWM WITHDRAW ERROR will occur. After position 18 is SUBSTITUTED on the RWM-OD the withdraw error will clear.

b.

A RWM WITHDRAW ERROR will occur. After Control Rod 18-15 is BYPASSED on the RWM-CC (Computer Chassis) the withdraw error will clear.

c.

Both RWM INSERT and WITHDRAW BLOCKS will occur. After position 18 is SUBSTITUTED on the RWM-OD both rod blocks will clear.

d.

Both RWM INSERT and WITHDRAW BLOCKS will occur. After Control Rod 18-15 is BYPASSED on the RWM-CC (Computer Chassis) both blocks will clear.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 67 2002 ILC SRO Written Exam 1 Point

67. Review the indication given in the Support Material Booklet The plant was at Full power.

A RWCU Pump running with both A and B RWCU Beds in Service.

The A SBLC pump is tagged out to replace the motor.

A transient occurred resulting in an Electrical ATWS.

You have been directed to inject with SBLC.

You have placed the Handswitch (HS-2613) for SBLC in the position shown in the Support Material Booklet and observe the indications shown.

The following plant conditions currently exist:

 LLS is controlling RPV pressure.

 RPV level control is set at 158 inches in auto and controlling level.

 SBLC system flow indicator is indicating 0 GPM

 SBLC pump discharge pressure is indicating 1375 psig

 SBLC tank level is reading 88% and stable What is the status of the following?

MO-2701 RWCU Suction Outboard Isolation Valve MO-2740 RWCU Return Header Outboard Isolation Valve A RWCU pump

a.

MO-2701 - CLOSED MO-2740 - OPEN A RWCU pump - OFF

b.

MO-2701 - OPEN MO-2740 - CLOSED A RWCU pump - ON

c.

MO-2701 - OPEN MO-2740- OPEN A RWCU pump - ON

d.

MO-2701 - CLOSED MO-2740 - CLOSED A RWCU pump - OFF

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 68 2002 ILC SRO Written Exam 1 Point

68. Assuming a normal SDC alignment with the B RHR loop in SDC.

The B RHR pump is running at 4300 gpm.

The B RHRSW pump is running at 2000 gpm.

MO 1909 RHR Shutdown Cooling Outboard Isolation Valve indicates OPEN.

MO 1939 RHR HX 1E-201B Inlet Throttle Valve indicates DUAL.

MO 1940 RHR HX 1E-201B Bypass Valve indicates DUAL.

MO 1947 RHR HX 1E-201B Service Water Outlet Isolation Valve indicates DUAL.

The STA reports a cooldown rate of 70OF/hr.

The OSS directs you to achieve a cooldown rate between 40 and 60OF/hr.

Which of the following panel manipulation would be appropriate in achieving this order?

(Assume you place the handswitch for the indicated MO in the given direction for one second and then recalculate the cooldown rate.)

a.

CLOSE on MO 1909.

b.

OPEN on MO 1939.

c.

OPEN on MO 1940.

d.

OPEN on MO 1947.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 69 2002 ILC SRO Written Exam 1 Point

69. A non-selected control rod at position 36 is uncoupled and the control blade is stuck.

The RO will be selecting and WITHDRAWING this control rod fully.

Which of the following CORRECTLY describes when the uncoupled control rod can be identified using RPIS indications only?

a.

As soon as the control rod is selected.

b.

When the selected control rod is withdrawn from position 36 to position 38.

c.

After the RMCS Timer times out with the selected control rod at position 48.

d.

When the selected control rod has withdrawn past position 48 independent of the RMCS Timer.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 70 2002 ILC SRO Written Exam 1 Point

70. Which of the following is utilized to automatically select the appropriate RBM upscale trip setpoint when the RBM is required to be in operation?
a.

Steam Flow

b.

Reference APRM

c.

Averaging Circuit

d.

Turbine 1st Stage pressure

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 71 2002 ILC SRO Written Exam 1 Point

71. The plant is at full power.

HPCI was running for a surveillance test with RHR, RHRSW, and ESW running as required for support.

Torus temperature reached the EOP 2 entry condition during the surveillance.

The OSS entered EOP 2 on Torus water temperature and Torus Cooling was MAXIMIZED with all RHR and RHRSW pumps running at rated flows.

Currently:

HPCI is secured and Torus Water temperature is 2OF above the EOP 2 entry temperature and slowly lowering.

Torus Cooling is still MAXIMIZED.

Bus 1A3 receives a bus Lockout.

Which of the following would be the expected status of Torus Cooling with no operator action?

a.

B RHR Loop would be operating within limits.

b.

The A RHR Loop header would be below the allowed pressure.

c.

Torus Cooling would no longer be MAXIMIZED as directed by EOP 2.

d.

B and D RHR pumps would be above their maximum allowed flow rates.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 72 2002 ILC SRO Written Exam 1 Point

72. SRO ONLY The plant was at full power.

A transient occurred and a SCRAM was successfully inserted.

RPV water level is 195 inches and stable.

CV4371A is overridden OPEN.

Containment Sprays have been unavailable.

The 1C03 operator reports Containment Sprays are now available.

The OSS requests Containment parameters.

The 1C03 operator reports the following:

 Drywell pressure 40 psig rising slowly

 Drywell temperature upscale (> 350OF)

 Torus pressure 40 psig rising slowly

 Torus temperature 97 OF rising slowly

 Torus level 10.5 feet rising slowly The OSS directs the 1C03 operator to initiate Torus and Drywell Sprays.

Why is the direction for sprays CORRECT/INCORRECT AND what other actions are required?

a.

CORRECT due to Torus pressure greater than 11 psig.

Direct the 1C05 operator to Maximize Torus Cooling.

b.

CORRECT due to Drywell temperature above 280OF.

Enter Emergency Depressurization (ED) and direct the 1C05 operator to OPEN 4 ADS/SRVs.

c.

INCORRECT due to possible brittle fracture failure of Recirc piping with current containment conditions.

Direct the 1C05 operator to Maximize Torus Cooling.

d.

INCORRECT due to possible containment damage with current containment conditions.

Enter Emergency Depressurization (ED) and direct the 1C05 operator to OPEN 4 ADS/SRVs.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 73 2002 ILC SRO Written Exam 1 Point

73. SRO ONLY The plant has entered ATWS from full power.

Plant conditions are as follows:

 RPV pressure is 900 psig.

 Torus level is 9.9 ft. and stable.

 Torus temperature is 145OF and rising.

Which one of the following is the LOWEST Torus water temperature at which an Emergency Depressurization must be performed per the EOPs for these conditions?

a.

150OF

b.

160OF

c.

170OF

d.

180OF

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 74 2002 ILC SRO Written Exam 1 Point

74. SRO ONLY The plant was at full power when a transient required EOP 1 and EOP 2 entry.

All RPV Water level instrumentation was subsequently lost.

The following plant conditions exist:

 All Control Rods are inserted.

 All SRV handswitches are in open and only 3 SRVs are open.

 All available injection sources are injecting into the RPV at maximum flow.

 RPV pressure is 60 psig and stable.

 Torus pressure is 3 psig and stable.

 Drywell Temperature is 275OF increasing slowly.

With the indicated plant conditions what actions are required?

a.

Adequate core cooling is NOT assured. Enter the SAGs.

b.

ADS/SRV operation is NOT assured. Initiate Drywell Sprays per EOP 2.

c.

Containment integrity is NOT assured. Initiate Torus Sprays per EOP 2.

d.

Core submergence is NOT assured. Enter ED and open Main Steam Line Drains.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 75 2002 ILC SRO Written Exam 1 Point

75. SRO ONLY The plant is at power.

Annunciator 1C08B B-11 250V DC Battery 1D4 Disconnected alarms.

The Auxiliary Operator reports 1D40 Ckt 01 has tripped OPEN.

AOP 388 Loss Of 250 VDC Power is entered by direction of the OSS.

One attempt is made to reclose the breaker 1D40 Ckt 01 but it will NOT CLOSE in.

All 250 VDC buses remain energized from 1D43 250 VDC Battery Charger.

1D44 250 VDC Battery Charger is operable.

Which of the following is correct in regards to the given conditions?

a.

With no 250 VDC buses lost AND 1D44 operable no LCO entry is required.

b.

Enter LCO 3.0.3 due to the loss of safety function based on the total loss of 250 VDC.

c.

Enter LCO 3.8.4 DC Sources-Operating Condition C due to the loss of 250 VDC being able to supply peak power during all events.

d.

Due to the large load imposed by the HPCI system on 250 VDC within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> deenergize MCC 1D41 and enter LCO 3.5.1 ECCS - Operating Condition F for HPCI. All other 250 VDC loads remain operable.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 76 2002 ILC SRO Written Exam 1 Point

76. SRO ONLY The plant is at full power.

CV1062 MSR 1E-18A 1st Stage Scavenging Steam Isolation Valve fails CLOSED.

Upon investigation it is determined the valve will NOT OPEN and will have to be repaired.

(Assume the repair will be completed when the parts arrive in 4 days)

Which one of the following is correct for the continued plant operation with these conditions?

a.

ARP 1C07B B-3 MSR 1st Stage Drain Tank 1T-91A LO Level directs the SHUTDOWN of First and Second stage reheat on both MSRs to prevent CHUGGING within the MSR tube bundles.

b.

ARP 1C07B B-3 MSR 1st Stage Drain Tank 1T-91A LO Level directs power change be limited to a step change of 5% and overall power changes to <7 MWe/minute to prevent drain tank flashing.

c.

OI 646 Extraction Steam System directs power change be limited to a step change of 5%

and overall power changes to <7 MWe/ minute to prevent drain tank flashing.

d.

OI 646 Extraction Steam System directs the SHUTDOWN of First and Second stage reheat on both MSRs to prevent CHUGGING within the MSR tube bundles.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 77 2002 ILC SRO Written Exam 1 Point

77. A trainee is synchronizing 1G 31 A SBDG to the 1A3 bus.

The following conditions are present during synchronizing the SBDG:

 The incoming voltage is slightly HIGHER than running voltage.

 The synchroscope is rotating slowly in the clockwise direction.

The trainee places the A SBDG output breaker to the close position when the synchroscope is at the 3 oclock position.

Which of the following describes the expected breaker response?

The A SBDG output breaker will

a.

close and then trip open due to A SBDG overspeed trip.

b.

close and then trip open due to an instantaneous overcurrent trip.

c.

remain open due to the sync-check relay sensing excessive current differential.

d.

remain open due to the sync-check relay sensing excessive incoming to running phase angle differential.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 78 2002 ILC SRO Written Exam 1 Point

78. Of the systems listed below which one meets the requirements needed for the following situation?

The plant is installing a new component.

The component is NOT safety related or essential to plant safety.

However, power interruptions to this component should be avoided.

The plant power supply to the component must have 3 power sources, one normal source and two alternate sources.

Upon loss of power to the normal power supply the system must be able to AUTOMATICALLY align to either of the two alternate sources WITHOUT prolonged loss of power (less than 2 seconds).

a.

The 125 VDC Power Supply System

b.

The Instrument A.C. Control System.

c.

The Uninterruptible A.C. Control Power System.

d.

Reactor Protection System Distribution Panel 1Y30

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 79 2002 ILC SRO Written Exam 1 Point

79. The plant is at power.

Annunciator 1C35A Offgas Stack KAMAN 9 & 10 HI RAD or Monitor Trouble alarms.

Offgas Stack flow has not changed.

The Chemist reports the Normal Range sample pump is not working.

All other Offgas Stack KAMAN equipment is functional.

Which of the following is correct?

a.

The KAMAN Normal Range is INOPERABLE. The Accident Range is OPERABLE.

b.

The KAMAN Normal Range is OPERABLE. The Accident Range is INOPERABLE.

c.

Both KAMAN Normal and Accident Ranges are INOPERABLE.

d.

Both KAMAN Normal and Accident Ranges are OPERABLE.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 80 2002 ILC SRO Written Exam 1 Point

80. During shiftly annunciator checks the annunciators do not alarm on panel 1C40 Fire Protection.

AOP 302.2 Loss of Alarm Power is entered.

There are NO other annunciators in alarm.

Which of the following panels has the breaker that supplies power to 1C40 and would give these indications if the breaker had tripped open?

a.

1D13

b.

1D50

c.

1Y11

d.

1Y23

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 81 2002 ILC SRO Written Exam 1 Point

81. SRO ONLY The plant is at 85% power.

Preparations are under way for a refueling outage.

Contractors mistakenly lifted the RCIC Room Equipment Hatch covers located in the yard outside the Reactor Building South side.

While attempting to replace the RCIC hatch cover, the rigging broke and the hatch plug fell into the RCIC room and is currently at the bottom of the RCIC Room stairs.

The Second Assistant reports that the RCIC system was NOT damaged.

Which of the following action AND reason is correct?

a.

Place the mode switch out of RUN within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> due being outside analyzed design bases.

b.

Enter T.S. LCO 3.0.3 immediately due to a loss of safety function for both SBGT systems being inoperable based on the inability to meet SR 3.6.4.1.3 to maintain 0.25 inches of vacuum water gauge in Secondary Containment.

c.

Declare Secondary Containment Inoperable and restore the RCIC Equipment hatch within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. This allows time to fix the RCIC Equipment hatch and takes into consideration that without this hatch installed a DBA LOCA could release radioactivity at ground level.

d.

Within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> initiate administrative controls to maintain RCIC Room HELB doors CLOSED except for essential access to prevent unmonitored contamination release to the environment in the event of a failure of primary containment in the Reactor Building.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 82 2002 ILC SRO Written Exam 1 Point

82. SRO ONLY The Plant was at 60% power.

A lightning strike caused the following loads on 1A1 to trip:

 A Recirc MG Set

 A Circ Water Pump The plant has been stabilized with RPV Water level controlling in the normal level band.

The 1C05 operator reports that we are in the Buffer Region on the Power to Flow Map.

Which procedure and direction is correct for these conditions?

a.

Enter AOP 255.2 Power/Reactivity Abnormal Change and direct the 1C05 operator to monitor APRMs for undamped oscillations.

b.

Enter IPOI 3 Power Operations (35% to 100% Power). IPOI 3 directs inserting a Manual SCRAM when the plant enters the Buffer Region on the Power to Flow Map.

c.

Enter AOP 304.1 Loss of 4160V Non-Essential Electrical Power and conduct a Rod Withdrawal briefing in preparation for Withdrawing Control Rods to exit the Buffer Region.

d.

Enter IPOI 4 Shutdown and direct the 1C05 operator to run the B Recirc pump to Minimum. When B Recirc is at Minimum perform a Rod movement briefing in preparation for Reactor Shutdown.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 83 2002 ILC SRO Written Exam 1 Point

83. SRO ONLY The plant is at power.

A phone call is received in the Control Room with the report of a loud noise in the Condensate Pump area.

The following annunciator are received on 1C07B:

 B-9 Air Compressor Facility Trouble

 C-9 Service Air Header LO Pressure

 A-10 Instrument Air Dryers 1T-265A/B Trouble 1K-90 A, B, and C are running and loaded.

The Auxiliary Operator reports the problem is confined to the in service Air Dryer and he will be shifting to the standby dryer.

Instrument Air Header pressure reached 75 psig and is starting to recover.

Besides AOP 518 Failure of Instrument and Service Air what would cause entry into another AOP based on these plant conditions and which AOP would be entered?

a.

CV3039 Instrument Air Header Isolation Valve isolates at 80 psig causing the CRD Flow Control valves to CLOSE. Enter AOP 255.1 Control Rod Movement/Indication Abnormal.

b.

Cooling Tower Basin level fails high causing the River Water Makeup valves to CLOSE.

Enter AOP 410 Loss of River Water Supply.

c.

Partial loss of Extraction Steam to the Feedwater Heaters occurs. Enter AOP 646 Loss of Feedwater Heating.

d.

CV 4108 Discharge to Offgas Stack Isolation Valve CLOSES. Enter AOP 672.1 Loss of Offgas System.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 84 2002 ILC SRO Written Exam 1 Point

84. The Traversing In-core Probe System was in service when a Group 2 Containment Isolation signal is received.

One probe does NOT automatically retract.

The key lock switch on the TIP Valve Control Monitor has been placed to the FIRE position.

Which of the below correctly describes the control room indication(s) of this condition?

a.

The SHEAR VLV MONITOR light is OFF.

b.

The GROUP 2 ISOLATION light is OFF.

c.

The BALL VALVE CLOSED light is ON.

d.

The SQUIB MONITOR light is ON.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 85 2002 ILC SRO Written Exam 1 Point

85. SRO ONLY The plant is at power.

You are the OSS and HPCI is being returned to service following repairs to 1P218 HPCI Auxiliary Oil Pump.

In what procedure do you find general guidance on checks that should be performed prior to declaring the HPCI system operable?

a.

ACP 1403.3 Modification Acceptance Test Control Program

b.

ACP 1415.3 Inspection Trending Program

c.

MD-24 Post Maintenance Testing Program

d.

MD-5 Conduct of Maintenance

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 86 2002 ILC SRO Written Exam 1 Point

86. SRO ONLY Which of the following can be used during venting the containment irrespective of radiation release but does NOT require plant entry?
a.

SEP 301.1 Torus Vent Via SBGT.

b.

SEP 301.3 Torus Vent Via Hardpipe Vent.

c.

SEP 303.1 Air Purge for H2 Control in SAGs.

d.

SEP 303.2 N2 Purge for H2 Control in SAGs.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 87 2002 ILC SRO Written Exam 1 Point

87. During vessel re-assembly the Head Bolts for the Steam Separator and Shroud Head Assembly were NOT tightened.

Which of the following indications would operators see?

a.

The Reactor will go critical several rods early.

b.

Recirc Pump flow mismatch will be greater at high power.

c.

At higher Recirc flow rates as flow is increased power will NOT increase as expected.

d.

The GEMAC Level instrument reference legs will experience flashing at Recirc flow rates greater than 40 Mlb/hr.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 88 2002 ILC SRO Written Exam 1 Point

88. Review the indication given in the Support Material Booklet The plant is at power.

The B Recirc MG Set Scoop tube is locked.

You are directed to take Local control of the B Recirc MG Set Scoop tube.

Review the picture in the Support Material Booklet.

From the labeled components choose which one performs each of the following functions?

1) Deenergizes the brake.
2) Mechanically releases brake tension to allow manual turning of the hand crank.
3) Proper Hand Crank location when adjusting scoop tube position.
a.
1) B
2) A
3) D
b.
1) B
2) F
3) D
c.
1) C
2) A
3) E
d.
1) C
2) F
3) E

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 89 2002 ILC SRO Written Exam 1 Point

89. SRO ONLY The plant is at power.

A problem with plant valving allows Condensate Storage Tank (CST) level to drop to 7.4 feet in both CSTs.

Level is being restored at 0.1 ft every 15 minutes.

Which of the following is correct concerning the operability of both HPCI and RCIC?

Both HPCI and RCIC are

a.

inoperable due to less than 75,000 gallons of water available for RPV makeup.

b.

inoperable since there is no assurance the discharge piping can be maintained full using the CSTs.

c.

operable as long as the CST level is restored to greater than 75,000 gallons of water within the next 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

d.

operable as long as their discharge piping is lined up to the CRD system for keep fill within one hour.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 90 2002 ILC SRO Written Exam 1 Point

90. SRO ONLY Operators have been responding to problems in the Offgas system. The following conditions have been observed:

 High range Offgas flow peaked at 100 scfm and is now stable at 50 scfm.

 The in-service Recombiner temperatures are at 600F and have been rising slowly throughout the transient.

 Offgas pressure is at 20 in. Hg Abs and steady.

 Hydrogen concentration as read by both Offgas Hydrogen Analyzers is 4.5% and stable.

What, if any, actions must be taken, in response to the above listed situation?

a.

There are no actions to be taken at this time.

b.

Increase steam pressure to the operating SJAE to about 300 psig.

c.

Place all of the loop seal drain valve handswitches in OPEN within 5 minutes to reduce system pressure to normal.

d.

Reduce the Offgas hydrogen concentration to <4% in 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 91 2002 ILC SRO Written Exam 1 Point

91. SRO ONLY Reactor power is 40% when an EHC failure causes the Bypass and Control valves to go full open.

The MSIVs fail to automatically close, when required, but are manually closed.

Prior to MSIV closure, which of the following combinations of reactor power and reactor pressure would indicate that a safety limit violation had occurred?

a.

Reactor power is 35% and RPV pressure is 790 psig.

b.

Reactor power is 30% and RPV pressure is 775 psig.

c.

Reactor power is 20% and RPV pressure is 770 psig.

d.

Reactor power is 10% and RPV pressure is 750 psig.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 92 2002 ILC SRO Written Exam 1 Point

92. A new A1 control rod sequence is to be loaded into the RWM.
1) From what RWM panel is the new sequence loaded into RWM memory AND
2) from what panel is the A1 sequence selected for RWM to enforce?
a.
1) RWM-OD (1C05 Operator Display)
2) RWM-OD (1C05 Operator Display)
b.
1) RWM-OD (1C05 Operator Display)
2) RWM-CC (1C28 Computer Chassis)
c.
1) RWM-CC (1C28 Computer Chassis)
2) RWM-OD (1C05 Operator Display)
d.
1) RWM-CC (1C28 Computer Chassis)
2) RWM-CC (1C28 Computer Chassis)

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 93 2002 ILC SRO Written Exam 1 Point

93. A reactor startup is in progress.

Conditions just prior to the startup and currently are listed below:

Beginning of Startup Currently

 SRM A at 9 cps SRM A at 85 cps

 SRM B at 11 cps SRM B at 100 cps

 SRM C at 8 cps SRM C at 90 cps

 SRM D at 10 cps SRM D at 95 cps

 Moderator temperature at 148F Moderator temperature at 149F The reactor is NOT critical and you still have one rod left to pull to complete the A12 sequence.

In order to pull this control rod to continue the startup, what must you do per IPOI-2 concerning the method of control rod withdrawal?

a.

Change from continuous withdrawal to group notch withdrawal.

b.

Change from continuous withdrawal to single rod notch withdrawal.

c.

Change from single rod notch withdrawal to group notch withdrawal.

d.

Change from single rod notch withdrawal to continuous rod withdrawal.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 94 2002 ILC SRO Written Exam 1 Point

94. SRO ONLY Who has the responsibility to approve radiological exposures in excess of 10CFR20 limits?
a.

OSC Supervisor.

b.

Emergency Coordinator.

c.

Health Physics Supervisor.

d.

Site Radiological Protection Coordinator.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 95 2002 ILC SRO Written Exam 1 Point

95. The 1C03 operator is performing an Air Purge (De-inerting) the Primary Containment.

Which of the following radiation-monitoring systems monitor the atmosphere that is exhausted through the Drywell/Torus vent valves?

a.

Reactor Building Vent KAMAN monitors (KAMAN 3 through 8)

b.

Offgas Vent Pipe Rad Monitors (RM-4116A & B) ONLY

c.

Offgas Stack KAMAN monitors (KAMAN 9 & 10) ONLY

d.

Offgas Vent Pipe Rad Monitors (RM-4116A & B)

AND Offgas Stack KAMAN monitors (KAMAN 9 & 10)

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 96 2002 ILC SRO Written Exam 1 Point

96. The plant is being started up following a refueling outage.

Inspectors are in the Drywell performing the 400-psig inspection.

Plant conditions are as follows:

 RPV pressure is 350 psig

 Reactor Power is 6%

Which of the following evolutions would NOT be allowed while the inspectors are still in the Drywell?

a.

Perform a heavy lift with the Reactor Building Crane.

b.

Close the inboard Drywell Personnel Hatch.

c.

Movement of fuel within the Fuel Pool.

d.

Raise Pressure set to 390 psig.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 97 2002 ILC SRO Written Exam 1 Point

97. Which of the procedures listed below would require a DCF to change if you determine that performing one of the steps would lead to serious personnel injury?
a.

ODI 19 Tagging Practices.

b.

AOP 301 Loss of Essential Electrical Power.

c.

EOP 2 Primary Containment Control Flow Chart.

d.

SAG 1 Primary Containment Flooding Flow Chart.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 98 2002 ILC SRO Written Exam 1 Point

98. SRO ONLY Plant conditions are as follows:

 SCRAM conditions exist but control rods did not insert.

 Reactor power is 15%.

 SBLC is injecting.

 The MSIVs are CLOSED and LLS is controlling pressure.

 RPV water level is 125 inches and is being deliberately lowered.

 Torus temperature is 115OF.

Which one of the following is the primary reason for deliberately lowering RPV water level under these conditions?

a.

To promote boron mixing.

b.

To prevent exceeding a thermal limit.

c.

To minimize the challenge to the fuel cladding.

d.

To minimize the threat to primary containment integrity.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 99 2002 ILC SRO Written Exam 1 Point

99. The EOPs have been entered and plant conditions have degraded such that SAG entry is required.

The TSC is NOT ready to assume control.

Which of the following is correct?

The operating crew should

a.

continue implementing the current EOP actions until the TSC is ready to transition to the SAGs.

b.

exit the EOP which directs the entry into the SAGs and continue to implement all other EOPs which are entered.

c.

exit the EOP leg that is directing the SAG entry and continue to implement all other EOPs legs in effect.

d.

enter the SAG that is directed and when the TSC is ready, turnover all actions which were directed from the SAGs entered.

QF-1030-02 Rev. 0 (FP-T-SAT-30)

Rev. 0 Senior Reactor Operator, 50007 Duane Arnold SRO Exam.doc

- 100 2002 ILC SRO Written Exam 1 Point 100. To place the Reactor Core in a low energy state, reduce RPV temperature, and maintain RPV water level above the top of active fuel to prevent Fuel Cladding temperature from exceeding 1500OF, is the bases for which EOP?

a.

EOP 1

b.

EOP 2

c.

EOP 3

d.

EOP 4