October 25, 2002 Mr. James Scarola, Vice President Shearon Harris Nuclear Power Plant Carolina Power & Light Company Post Office Box 165, Mail Code: Zone 1 New Hill, North Carolina 27562-0165

SUBJECT:

SHEARON HARRIS NUCLEAR POWER PLANT - REQUEST FOR ADDITIONAL INFORMATION (RAI) ON AMENDMENT APPLICATION REGARDING ADDITION OF METHODOLOGY REFERENCES TO THE CORE OPERATING LIMIT REPORT (TAC NO. MB6226)

Dear Mr. Scarola:

By letter dated August 28, 2002, you submitted an amendment application regarding the addition of methodology references to the core operating limit report for the Shearon Harris Nuclear Power Plant. The NRC staff reviewed the information that you provided in the subject amendment application and identified the need for further information as described in the enclosed RAI.

This request for information was discussed by the NRC staff, Framatome, and the licensee during a telephone conversation on October 7, 2002, and a mutually agreeable schedule for a response by November 26, 2002, was established for your comprehensive response to the RAI.

If you have any questions, please contact me on (301) 415-1478.

Sincerely,

/RA/

Ram Subbaratnam, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-400

Enclosure:

RAI cc w/encl: See next page

OFFICE PM:PDII-2 INTERN:PDII-2 LA:PDII-2 DSSA:SRXB DSSA:SRXB SC:PDII-2 NAME RSubbaratnam MMcConnell EDunnington VKlein FAkstulewicz AHowe DATE 10\\24\\2002 10/24\\2002 10\\24\\2002 10/24\\2002 10/24\\2002 10\\25\\2002

SHEARON HARRIS NUCLEAR POWER PLANT REQUEST FOR ADDITIONAL INFORMATION (RAI) ON AMENDMENT REQUEST REGARDING ADDITION OF METHODOLOGY REFERENCES TO THE CORE OPERATING LIMIT REPORT TAC NO. MB6226 Carolina Power & Light Company is requested to provide the following additional information relating to the above amendment request:

1.

The NRCs safety evaluation of Topical Report EMF-2328(P)(A), Revision 0, PWR Small Break LOCA Evaluation Model, S-RELAP5 Based states a condition on the use of the ANF-RELAP code that still applies to the use of S-RELAP5. The statement is:

That while it has been shown in Reference 53 [Loomis, G.G., Summary of the Semiscale Program (1965-1986), NUREG/CR-4945, July 1987] that the thermal-hydraulic phenomena observed for breaks up to 10 percent of the cold leg flow area are the same, if the code is used for break sizes larger than 10 percent of the cold leg flow area additional assessments must be performed to ensure that the code is predicting the important phenomena which may occur.

Your submittal did not state the break size range for which you intend to use the code.

Please provide information that says what break size range you intend to use the code for, and if you intend to use the code for breaks larger than 10 percent of the cold leg flow area, also provide the required additional assessments.

2.

The NRCs safety evaluation of Topical Report EMF-2310(P)(A), Revision 0, SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors states in Section 5.0 Evaluation of S-RELAP5:

The staff notes, however, that a generic topical report describing a code such as S-RELAP5 cannot provide full justification for each specific individual plant application. The individual applicant must still provide justification for the specific application of the code which is expected to include as a minimum, the nodalization, defense of the chosen parameters, any needed sensitivity studies, justification of the conservative nature of the input parameters, and calculated results.

Your submittal did not include any justification of your specific application of the code.

Please provide the necessary information.

The delay with submitting this formal RAI was due to clarification of the time period needed by the licensee to submit a comprehensive response.

Mr. James Scarola Shearon Harris Nuclear Power Plant Carolina Power & Light Company Unit 1 cc:

Mr. William D. Johnson Mr. Robert J. Duncan II Vice President and Corporate Secretary Director - Site Operations Carolina Power & Light Company Carolina Power & Light Company Post Office Box 1551 Shearon Harris Nuclear Power Plant Raleigh, North Carolina 27602 Post Office Box 165, Mail Zone 1 New Hill, North Carolina 27562-0165 Resident Inspector/Harris NPS c/o U.S. Nuclear Regulatory Commission Mr. Robert P. Gruber 5421 Shearon Harris Road Executive Director New Hill, North Carolina 27562-9998 Public Staff NCUC 4326 Mail Service Center Ms. Karen E. Long Raleigh, North Carolina 27699-4326 Assistant Attorney General State of North Carolina Chairman of the North Carolina Post Office Box 629 Utilities Commission Raleigh, North Carolina 27602 Post Office Box 29510 Raleigh, North Carolina 27626-0510 Public Service Commission State of South Carolina Post Office Drawer 11649 Columbia, South Carolina 29211 Ms. Linda Coleman, Chairperson Board of County Commissioners of Wake County P. O. Box 550 Ms. Beverly Hall, Acting Director Raleigh, North Carolina 27602 Division of Radiation Protection N.C. Department of Environment and Natural Resources 3825 Barrett Dr.

Mr. Gary Phillips, Chairman Raleigh, North Carolina 27609-7721 Board of County Commissioners of Chatham County P. O. Box 87 Mr. Terry C. Morton Pittsboro, North Carolina 27312 Manager Performance Evaluation and Mr. James W. Holt, Manager Regulatory Affairs CPB 7 Support Services Carolina Power & Light Company Carolina Power & Light Company Post Office Box 1551 Shearon Harris Nuclear Power Plant Raleigh, North Carolina 27602-1551 P.O. Box 165, Mail Zone 1 New Hill, NC 27562-0165 Mr. Benjamin C. Waldrep Plant General Manager - Harris Plant Mr. John R. Caves, Supervisor Carolina Power & Light Company Licensing/Regulatory Programs Shearon Harris Nuclear Power Plant Carolina Power & Light Company P.O. Box 165, Mail Zone 3 Shearon Harris Nuclear Power Plant New Hill, North Carolina 27562-0165 P. O. Box 165, Mail Zone 1 New Hill, NC 27562-0165 Mr. John H. ONeill, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N Street, NW.

Washington, DC 20037-1128