John S.

Keenan Vice President A Progress Energy Company Brunswick Nuclear Plant APR 2 5 2002 SERIAL: BSEP 02-0090 TSC-2001-04 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 AND 50-324/LICENSE NOS. DPR-71 AND DPR-62 ADDITIONAL INFORMATION IN SUPPORT OF REQUEST FOR LICENSE AMENDMENTS TO ADOPT ALTERNATIVE RADIOLOGICAL SOURCE TERM (NRC TAC NOS. MB2570 AND MB2571)

Ladies and Gentlemen:

On August 1, 2001 (i.e., Serial: BSEP 01-0063), Carolina Power & Light (CP&L)

Company submitted a license amendment application to allow a full-scope implementation of an Alternative Radiological Source Term (AST) for the Brunswick Steam Electric Plant (BSEP), Units I and 2. Subsequently, by letter dated November 28, 2001 (i.e.,

Serial: BSEP 01-0136), CP&L provided copies of calculations supporting the AST radiological consequence analyses.

In a letter dated February 4, 2002 (i.e., Serial: BSEP 02-0019), CP&L provided a response to NRC Request for Additional Information (RAI) 1-6 regarding the Standby Gas Treatment System aerosol filter efficiency assumed in the AST radiological consequence analyses. CP&L's response stated that the AST radiological consequence calculations were being revised to use an assumed efficiency of 99 percent, rather than 99.99 percent, for each Standby Gas Treatment System filter train.

The radiological consequence calculation for a design basis accident (DBA) loss of coolant accident (LOCA), designated as calculation BNP-RAD-007, "DBA LOCA Radiological Dose with Alternate Source Term," has been updated to incorporate the revised assumption for Standby Gas Treatment System filter efficiency. The results for the loss-of-coolant accident are as follows:

Reie Dose Previous Dose (Rem, TEDE)

(Rem, TEDE)

EAB, Worst 2-Hour Dose 0.64 0.61 LLPZ, 30-Day Integrated Dose 1.36 1.34 P0 Box 10429 Southport, NC 28451

'> 91045T72496 F> 910.457 2803

Document Control Desk BSEP 02-0090 / Page 2 Revised Dose Previous Dose (Rem, TEDE)

(Rem, TEDE)

Control Room 3.62 3.40 EOF/TSC 1.15 1.04 A copy of the revised pages from Revision 1 of calculation BNP-RAD-007 is provided in.

By letter dated January 17, 2002, the NRC approved withholding Calculation BNP-RAD-007 from public disclosure in accordance with 10 CFR 2.790. The information in Revision 1 of Calculation BNP-RAD-007 is also considered to be proprietary to Applied Analysis Corporation (AAC) and should be withheld from public disclosure in accordance with 10 CFR 9.17(a)(4) and 10 CFR 2.790(a)(4). An affidavit attesting to this fact is provided in Enclosure 1. A non-proprietary version of the revisions to the calculation is not being provided because the entire calculation is considered proprietary to AAC.

Please refer any questions regarding this submittal to Mr. Ed T. O'Neil, Manager Regulatory Affairs, at (910) 457-2073.

Sincerely, WRM/wrm

Enclosures:

1. Applied Analysis Corporation Affidavit Regarding Withholding From Public Disclosure
2. Revisions to Calculation BNP-RAD-007, "DBA LOCA Dose with Alternate Source Term"

Document Control Desk BSEP 02-0090 / Page 3 John S. Keenan, having been first duly sworn, did depose and say that the information contained herein is true and correct to the best of his information, knowledge and belief; and the sources of his information are officers, employees, and agents of Carolina Power &

Light Company.

Notary (Seal)

My commission expires: R)]2-/04

Document Control Desk BSEP 02-0090 / Page 4 cc (with Enclosures 1 and 2):

U. S. Nuclear Regulatory Commission, Region II ATTN: Mr. Luis A. Reyes, Regional Administrator Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, GA 30303-8931 U. S. Nuclear Regulatory Commission ATTN: Mr. Theodore A. Easlick, NRC Senior Resident Inspector 8470 River Road Southport, NC 28461-8869 U. S. Nuclear Regulatory Commission (Electronic Copy Only)

ATTN: Mr. Brenda L. Mozafari (Mail Stop OWFN 8G9) 11555 Rockville Pike Rockville, MD 20852-2738 cc (without Enclosures):

Ms. Jo A. Sanford Chair - North Carolina Utilities Commission P.O. Box 29510 Raleigh, NC 27626-0510 Mr. Mel Fry Director - Division of Radiation Protection North Carolina Department of Environment and Natural Resources 3825 Barrett Drive Raleigh, NC 27609-7221

ENCLOSURE 1 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 AND 50-324/LICENSE NOS. DPR-71 AND DPR-62 ADDITIONAL INFORMATION IN SUPPORT OF REQUEST FOR LICENSE AMENDMENTS TO ADOPT ALTERNATIVE RADIOLOGICAL SOURCE TERM (NRC TAC NOS. MB2570 AND MB2571)

Applied Analysis Corporation Affidavit Regarding Withholdina From Public Disclosure

APPLIED ANALYSIS CORP.

AFFIDAVIT I, Juan M. Cajigas, being duly sworn, depose and state as follows:

1) I am the President of Applied Analysis Corp. ("AAC") and have reviewed the information described in paragraph (2) and sought to be withheld.
2) The information sought to be withheld is contained in the AAC proprietary calculations listed in Attachment A.
3) In making this application for withholding of proprietary information, AAC relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec.

552(b)(4), and the Trade Secrets Act, 18 USC Sec. 1905, and NRC regulations 10 CFR 9.

17(a)(4), 2.790(a)(4), and 2. 790(d)(1) for "trade secrets and commercial or financial information obtained from a person and privileged or confidential" (Exemption 4). The material for which exemption from disclosure is here sought is all "confidential commercial information", and some portions also qualify under the narrower definition of "trade secret",

within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Enerqy Proiect v. Nuclear Regqulatory Commission. 975F2d871 (DC Cir. 1992), and Public Citizen Health Research Group v. FDA 704F2d1280 (DC Cir.

1983).

4) Some examples of categories of information which fit into the definition of proprietary information are:

a) Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by AAC competitors without license from AAC constitutes a competitive economic advantage over other companies; b) Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, preparation, assurance of quality, or licensing of a similar service; c) Information which reveals cost or price information, production capacities, budget levels, or commercial strategies of AAC, its customers, or its suppliers; d) Information which reveals aspects of past, present, or future AAC customer-funded development plans and programs, of potential commercial value to AAC; e) Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.

The information sought to be withheld is considered to be proprietary for the reasons set forth in both paragraphs (4)a and (4)b, above.

5) The information sought to be withheld is being submitted to NRC in confidence. The information is of a sort customarily held in confidence by AAC, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by AAC, no public disclosure has been made, and it is not available in public

sources. All disclosures to third parties including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or proprietary agreements which provide for maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs (6) and (7) following.

6) Initial approval of proprietary treatment of a document is made by the manager of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge.

Access to such documents within AAC is limited on a "need to know" basis.

7) The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent authority, by the manager of the cognizant marketing function (or his delegate), and by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside AAC are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.
8) The information identified in paragraph (2), above, is classified as proprietary because it contains detailed methods and processes, which AAC has developed for the preparation of detailed safety analyses in support of the design and licensing of nuclear facilities.

The development of these methods and processes was achieved at a significant cost to AAC and derived from company experience that constitutes a major AAC asset.

9) Public disclosure of the information sought to be withheld is likely to cause substantial harm to AAC's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of AAC's nuclear safety analysis and technology base, and its commercial value includes development of the expertise to determine and apply the appropriate evaluation processes.

The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.

AAC's competitive advantage will be lost if its competitors are able to use the results of the AAC experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar results and conclusions.

The value of this information to AAC would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive AAC of the opportunity to exercise its competitive advantage to seek an adequate return on its investment in developing these analytical processes.

STATE OF PENNSYLVANIA

)

)

ss:

COUNTY OF BERKS

)

Juan M. Cajigas, being duly sworn, deposes and says:

That he has read the foregoing affidavit and the matters stated therein are true and correct to the best of his knowledge, information, and belief.

Executed at Reading, Pennsylvania, this Agx

/day of 2002.

Juan M. Cajigas Applied Analysis Corp.

Subscribed and sworn before me this day of 6 2002.

ary Public, State of I/ennsqvania Notarial Seall Yvonne D. Espig, Notary Public Cumru Twp., Berks County My Commission Expires Oct. 6, 2003 Member, pnnyvana Assoclaton of Notaries

ATTACHMENT A

1. BNP-RAD-007, DBA LOCA Radiological Consequence Dose with Alternate Source Term.

ENCLOSURE 2 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 AND 50-324/LICENSE NOS. DPR-71 AND DPR-62 ADDITIONAL INFORMATION IN SUPPORT OF REQUEST FOR LICENSE AMENDMENTS TO ADOPT ALTERNATIVE RADIOLOGICAL SOURCE TERM (NRC TAC NOS. MB2570 AND MB2571)

Revisions to Calculation BNP-RAD-007, "DBA LOCA Dose with Alternate Source Term"

CALCULATION TITLE AND APPROVAL COVER SHEET SYSTEM#

CALC. SUB-TYPE RAD PRIORITY CODE 4

QUALITY CLASS A

CAROLINA POWER & LIGHT COMPANY BNP-RAD-007 (CALCULATION #)

DBA LOCA Radiological Dose with Alternate Source Term (TITLE INCLUDING STRUCTURE/SYSTEM/COM PONENT)

BRUNSWICK NUCLEAR POWER PLANT UNIT 1 &2 APPROVAL Revision 1

Prepared By R. A. Crandall Date 6 ý 9zO*

Reviewed By W. M. Biggs Date e Design Supervisor Date (For Vendor Calculations) eN/A FORM OENP-303-1 (2102)

Date Owner's Review By

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

I LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE PAGES PAGE REV I

ATTACHMENTS Number of Pages 2

1-7 8

1-2 3

4-17 22 12 34 11 2

23 29 7

29 29 29 29 29 17 11 2

21 29 29 29 28 22 22 23 23 29 AMENDMENTS Letter Rev Number of Pages II Revision iv 111 iv V

1-6 7-9 10-14 15 16-34 35 36-132 133-134 135 136-137 138-143 144 145-156 157 158 159 160-161 162-163 164-166 167 Number 1

2 3

4 4a 4b 4c 4d 5

6 6a 7

8 9

10 11 12 12a 12b 13 14 15 16 17 18 19 20 21 22

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

iiI LIST OF EFFECTIVE PAGES PAGE REV ATTACHMENTS Number Revision Number of Pages 23 0

29 24 0

29 25 0

29 26 0

29 27 0

29 28 0

28 29 0

28 30 0

17 31 0

17 32 0

21 33 0

21 34 0

21 35 0

21 36 0

21 37 0

22 38 0

23 39 0

23 40 0

28 41 0

28 42 0

28 43 0

28 44 0

28 45 0

28 46 0

28 47 0

28 48 0

28 49 0

27 50 0

27 51 0

27 AMENDMENTS Letter Rev Number ofTPge Rev.

I1

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

iii LIST OF EFFECTIVE PAGES PAGE REV ATTACHMENTS Number Revision Number of Pages 52 0

16 53 0

16 54 0

16 55 0

19 56 0

19 57 0

19 58 0

17 59 0

17 60 0

17 61 0

20 62 0

20 63 0

27 64 0

27 65 0

27 66 0

27 67 0

27 68 0

27 69 0

17 70 0

19 71 0

27 72 0

27 73 0

27 74 0

27 75 0

17 76 1

21 77 0

28 78 0

28 79 0

27 80 0

27 81 1

20 82 0

26 AMENDMENTS Letter Rev Number of Pages

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

iv]

I LIST OF EFFECTIVE PAGES PAGE REV ATTACHMENTS Number Revision Number of Pages 83 0

25 84 0

26 85 0

26 86 0

46 87 0

28 88 0

27 89 0

8 90 0

42 91 1

61 92 0

60 93 0

36 94 0

59 95 0

58 96 0

39 97 0

42 98 1

13 99 0

28 100 0

28 AMENDMENTS Letter Rev Number of Pages

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

v Rev.

REVISION

SUMMARY

Rev. #

Date Revision Summary 0

6/08/01 Initial Issue 1

04/19/02 Revision 1 revised the final dose analyses that took credit for the SGTS particulate filters. For those analyses, the assumed filter efficiency of 99.99% was changed to 99%,

based on comments received during the NRC review. This affected the primary containment leakage cases, after the positive pressure period. The cases that were not used in the final bounding dose analyses (e.g.- those that took credit for drywell spray) were not revised. Attachments 76, 81 and 91 were revised. This change also affected 8, which calculates the activity released to the environment. The change also impacts the calculated activity loading on the CR and TSC filters as calculated in BNP-RAD-009. The calculated direct doses to CR/TSC personnel from the activity on the CR/TSC filters was recalculated in BNP-RAD-009, Rev. 1 and the revised doses incorporated into this calculation in the determination of the total dose in Table 6-2 1.

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

I Rev.

7 SCB Secondary Containment Bypass scfh flow unit, standard cubic feet per hour scfm flow unit, standard cubic feet per minute SGTS Standby Gas Treatment System SP Torus Suppression Pool SRP Standard Review Plan (NUREG-0800)

TB Turbine Building TEDE Total Effective Dose Equivalent (units of Rem)

TID Total Integrated Dose TSC Technical Support Center T1 Denotes Filter Removal Efficiency

1.0 PURPOSE

The purpose of this calculation is to evaluate the radiological consequences to the Control Room operators, the TSC operators, and at the BNP site boundaries (EAB & LPZ) resulting from a Design Basis Loss of Coolant Accident based on the Alternative Source Term. The objective of this calculation is to demonstrate compliance with IOCFR Part 50.67 (Reference 2.3), 10CFR Part 50 Appendix A GDC 19 (Reference 2.3), and Reference 2.4 for the CR/TSC operators and with 10CFR Parts 50.67 & Part 100 (Reference 2.3) and RG 1.183 Table 6 (Reference 2.1) for the site boundaries.

Caution - the dose calculations that take credit for spray removal of iodine are based on a spray cutoff time for elemental iodine that is non-conservative compared to the guidelines in Reg. Guide 1.183. See Owner Review Comment #15 for details.

Caution - the dose calculations that take credit for spray removal of iodine utilize a value of 3.33 Atm versus the documented value of 4.33 Atm when modeling radionuclide deposition within pipes for the SCB and MSIV leakage pathways. See Owner Review Comment #16 for details.

Caution -

the dose calculations that take credit for spray removal of iodine use the RADTRAD default breathing rates for the EAB. For release pathways where the time of "worst" two hour EAB dose is greater than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, the presented dose values are non conservative. See Owner Review Comment #14 for details.

Caution - Attachments 5, 20, 21, 37, 38, 39, 61, 62, and 70 use a SGTS aerosol removal efficiency of 99.99%. This is non-conservative compared to the allowable 99% efficiency.

However, these cases were not revised to the 99% efficiency, as these cases are not used in the final bounding dose totals.

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

81 1

2.0 REFERENCES

2.1 Regulatory Guide 1.183, "Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Plants", July 2000 2.2 NUREG-1465, "Accident Source Terms for LightWater Nuclear Power Plants", Final Report, Published February 1995 2.3 Code of Federal Regulations Title 10 - Energy, January 2001 2.4 Federal Register, Volume 64, No. 47, "Use of Alternative Source Terms at Operating Reactors", dated March 11, 1999 2.5 NUREG/CR-6604, "RADTRAD: A Simplified Model for RADonuclide Transport and Removal And Dose Estimation", Published April 1998 and Supplement 1 Dated 6/8/99 2.6 Calculation BNP-RAD-010 Revision 1, "Design Inputs for Accident Radiological Analyses" 2.7 NUREG/CR-0009, "Technological Bases for Models of Spray Washout of Airborne Contaminants in Containment Vessels", 10/78, Section 5.1.2 2.8 Calculation BNP-RAD-001 Revision 0, "Accident Offsite Radiological Atmospheric Dispersion Factors (Chi/Q)"

2.9 Calculation BNP-RAD-002 Revision 0, "Accident Control Room and TSC Radiological Atmospheric Dispersion Factors (Chi/Q)"

2.10 Calculation BNP-RAD-003 Revision 1, "Suppression Pool pH with Alternate Source Term" 2.11 Calculation BNP-RAD-006 Revision 0, "NUREG-0737 Item ll.B.2 - Mission dose Assessment for AEP and AST" 2.12 BNP Technical Specification 3.6.1.1, "Primary Containment" 2.13 BNP Technical Specification 5.5.12.e, "Primary Containment Leak Rate Testing Program" 2.14 BNP Piping Specification No. 248-117 Revision 17 2.15 Final Task Report T0802, "Radiation Sources", April 2001 2.16 NUREG-0800 Standard Review Plan 6.5.2, "Containment Spray as a Fission Product Cleanup System", Draft Revision 3, April, 1996 2.17 Calculation BNP-RAD-012 Revision 0, "Reactor Building Post-LOCA Drawdown Transient Analysis"

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

9 1

2.18 NUREG/CR-5966, "A Simplified Model of Aerosol Removal by Containment Sprays", June 1993 2.19 Crane Technical Paper No. 410, 13'h printing, "Flow of Fluid Through Valves, Fittings, and Pipes" 2.20 Sonntag & Van Wylen, "Introduction to Thermodynamics", ©1971 2.21 Federal Guidance Report 11, "Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion", Second Printing 1989 2.22 Federal Guidance Report 12, "External Exposure to Radionuclides in Air, Water, and Soil",

1993 2.23 NEDC-31858P-A, "BWROG Report for Increasing MSIV Leakage Rate Limits and Elimination of Leakage Control Systems", August 1999 It 2.24 Kocher, David C., "Radioactive Decay Data Tables, A Handbook of Decay Data for Application to Radiation Dosimetry and Radiological Assessments", 1981 2.25 Calculation BNP-RAD-009 Revision 1, "DBA LOCA Radionuclide Loading on Safety Filters" 2.26 BNP Drawings:

1-FP-02450 Sheet 1, Revision A & Sheet 2 Revision A 1-FP-02451 Sheet 1, Revision A 2-FP-2130 Sheet 1, Revision B & Sheet 2 Revision A 2-FP-2131 Sheet 1, Revision B & Sheet 2 Revision A 2-FP-2132 Sheet 1, Revision A & Sheet 2 Revision B 2-FP-2133 Revision A F-04082 Revision 27 And others as itemized in Table 6.11 2.27.

Final Task Report T0400, "Containment System Response", June 2001

Design Design Input Input No.

Secondary Containment Free Volume (2,588,900 ft3)

Secondary Containment Mixing (Not Credited)

Secondary Containment Bypass (10 scfh via Inboard MSIV Drain to Condenser, 10 scfh via HPCI Drain to Condenser, 3 scfh via RCIC Drain to Condenser). SCB Leakage is part of the overall 0.5 %/day Primary Leak Rate.

Secondary Containment Bypass (Drawings used for pipe deposition models - for list of drawings used, see calculation Table 6-11)

SGTS Flow Rate (4200 scfm maximum, 3000 scfm +/- 10% minimum)

SGTS Filter Rmoval Efficiencies (99%

aerosols, 99% elemental, 99% organic)

SGTS Filter Bypass (Included within Item 4.22 removal efficiencies; i.e., 0 cfm modeled bypass flow rate)

Suppression Pool Source Term (Same as Items 4.1 through 4.6, except no noble gases)

Suppression Pool Water Volume (86,450 ft minimum & 89,750 ft3maximum) 4.19b 4.20a 4.20b 4.21 4.22 4.23 4.24 4.25 4.26 4.27 4.28 4.29 ESF Leakage Rate Outside of RB (None)

Activity Release From ESF Liquids (Only radioiodines) 4.30 Suppression Pool Maximum Temperature (<

212 'F)

ESF Flash Fraction (10%, based on SP temperature less than 212 'F)

Radioiodine Species of ESF Leakage (97%

elemental, 3% organic)

ESF Release within RB (No Mixing, releases processed by RB SGTS)

MSIV Leakage Source Term (Same as Item 4.1 through 4.6)

"MSIV Leakage Rate (11.5 scfh in each of 4 Design Input Reference Ref. 2.17 Ref. 2.6 Item B.19 Ref. 2.6 Item B.19 Ref. 2.6 Item B.20 Ref. 2.6 Item B.35 Pertinent RG 1.183 Section (Ref. 2.1)

A4.3 A4, A4.4 A4, A4.4 A4, A4.5 Ref. 2.6 Item B.20 A4, A4.5 Ref. 2.6 Item B.21 A4, A4.6 Ref. 2.6 Item B.22 4 Ref. 2.6 Item B.23 Ref. 2.6 Item B.24, Ref. 2.1 Section 5.1 Ref. 2.6 Item B.25 A4 A.

A3, A4.6 A5, A5.1 A5, A5.1 I.

t

.A, Ai.2 Ref. 2.6 Item B.26

-l i AS, A5.2 Ref. 2.6 Item B.27 1

Ref. 2.6 Item B.'28 A, A.2 Ref. 2.6 ItemB.28 Ref. 2.6 Item B.29, Ref. 2.1 Section A5.3 Ref. 2.6 Item B.30 I-

-t A5, AS.4, AS.5 Ref. 2.6 Item B.31, Ref. 2.1 Section 5.5 Ref. 2.6 Item B.32, Ref. 2.1 Section 5.6 Ref. 2.6 Item B.33 A5, A5.3 A5, A5.4, A5.5

-t A5, AZA

-t AS, AS.6 Ref. 2.6 Item B.34 A6, A6.1 4

1 A6, A6.2 1

4.19a ESF Leakage Rate (1 gpm provided, 20 gpm conservatively used)

ESF Leakage Rate Timing (For full 30 day LOCA 4.31 4.32 4.33 4.34 4.35 A5, A5.2 A5, A5.3 A5, A5.4, A5.5 A5 A5.6 A5, A5.6 A6, A6.2 I

A4, A4.4 A4, A4.6 A5, A5.2 A5, A5.2

CAROLINA POWER & LIGHT COMPANY BRUNSWICK NUCLEAR PLANT Calculation No.

BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

35 1

6.2.7 RADTRAD Pathway 3 represents the 0.4559% Primary Containment Leakage Term:

1. The Primary Containment leakage rate equals 0.5% per day (DI 4.14). The 0.5%/day by weight primary leakage term addresses all leakage from the Primary Containment (with the exception of leakage past the MSIVs) including leakage which bypasses the Secondary Containment. The Case 2 RADTRAD model addresses only the Primary Containment Leakage that does not bypass the Secondary Containment. Furthermore, Case 2 addresses the Primary Containment Leakage term only following the PPP. Primary Containment Leakage during the PPP is addressed as Case 1. Secondary Containment Bypass is addressed as Cases 3 through 6. MSIV Leakage is addressed as Cases 7 & 8.
2. PPP duration equals 5 minutes (actual RADTRAD model input for the PPP is 5 minutes minus the 2 minute time to onset of release, DI 4.5, or 3 minutes)
3. Use RADTRAD filtered pathway. Zero cfm flow for the first 3 minutes (0.05 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />), as the Primary Leakage before this period is addressed in Case 1. After 0.05 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />, filtered Primary Leakage is 0.51922 cfm (flow rate equivalent to 0.4559 %/day Primary Leakage previously evaluated in calculation section 6.1.7 item 2). SGTS filter removal efficiencies are 99.99% f&r aerosols (revised to 99% in Rev. 1 for final cases in Attachments 76 and 81),

99% for elemental iodines, and 99% for organic iodines (DI 4.22). Primary Leakage is reduced by a factor of 2 or 50% at 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> post-LOCA (DI 4.15).

The ILRT which confirms that the Primary Leakage is less than 0.5%/day is performed at a pressure of 49 psig (DI 4.16). Per Calculation Assumption 3.3, the post-LOCA DW pressure at 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> is less than 12.25 psig; thus, the DW pressure 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> post -LOCA is a factor of four (4) lower than design ILRT test pressure. From Reference 2.19 equation 3.20, flow is a function of the square root of delta pressure. If the reduction in DW AP is a factor of 4 [(49 psig - 14.7 psia) / (12.25 psig - 14.7 psia)], then the reduction in flow is a factor of the square root of 4, or 2.

Therefore, at 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> post-LOCA, the Primary Leakage flow rate is reduced by a factor of 2 to 0.25961 cfm, which continues for the duration of the accident. SGTS filter efficiencies remain unchanged from those given above.

4. No additional inputs used.

6.2.8 RADTRAD Pathway 4 represents the Normal/Emergency CR Outside Air Intake Pathway:

1. Same as BNP Normal/Emergency CR Outside Air Intake Pathway in calculation section 6.1.8.

6.2.9 RADTRAD Pathway 5 represents the CR Unfiltered Air Inleakage Pathway:

1. Same as BNP Normal/Emergency CR Unfiltered Air Inleakage Pathway in calculation section 6.1.9.

6.2.10 RADTRAD Pathway 6 represents the CR Exhaust Air Pathway:

1. Same as BNP Normal/Emergency CR Exhaust Air Pathway in calculation section 6.1.10.

CAROLINA POWER & LIGHT COMPANY BRUNSWICK NUCLEAR PLANT CALCULATION SHEET Calculation No.

BNP-RAD-007 Page No.

133 1

Table 6 Unprotected CR/TSC Dose Case File Name (Attachment No.)

30 Day 30 Day Unprotected CR Unprotected TSC Dose (Rem)

Dose (Rem)

PPPRB5 10000cfmNoSpray_l VolCR20 (58) 0.0242 PPPRB5 10000cfmNoSpray 1VolTSC120 (69) 0.0018 PPPST5 lptS lOOOOcfmNoSprayl VolNewLeak-pCR20 (76) 0.6586 PPPST5_Ipt8 10000cfmNoSpray_ VolNewLeak-pTSC120 (81) 0.4483 SCBMSLAlternate_10000cfmNoSpray_ VolNewLeakCR20 (77) 0.7821 SCBMSLAlternate_10000cfmNoSpray_ VolNewLeakTSC 120 (82) 0.1429 SCBHIPCI Alternate 10000cfmNoSpray_ VolNewLeakCR20 (78) 0.7624 SCBHPCIAlternate_10000cfmNoSpray-lVolNewLeakTSC120 (83) 0.1393 SCBRCICAlternate_10006cfmNoSprayl VolNewLeakCR20 (79) 0.2344 SCBRCICAlternate 10000cfmNoSpray 1VolNewLeakTSC 120 (84) 0.0428 MSIVAlternate_10000cfmNoSprayjlVolNewLeakCR20 (80) 3.8861 MSIVAlternate_10000cfmNoSpray_ VolNewLeakTSC 120 (85) 0.7095 ESFRB5 10000cfmCR20 (31) 0.0196 ESFRB5 10000cfmTSC120 (54) 0.0015 ESFST5 10000cfmCR20 (33) 0.1710 ESFST5_ 10000cfmTSC 120 (57) 0.1158 Totals:

6.5384 1.6019 Rev.

I I

b. The external cloud dose summarized in Table 6-16 represents the unshielded whole body dose experienced by an individual within the cloud for the full 30 day LOCA duration. The dose contribution to the CR operators within the CR from this external cloud may be evaluated by calculating the reduction in the Table 6-16 dose resulting from the 2" of concrete (CR walls and roof) shielding the CR operators from this source. Additionally, although not credited here, further reduction of this dose based on CR occupancy factors could be employed. From Reference 2.11 Tables 9 & 10, the effective attenuation of the shine dose to the CR operators from the external cloud by 2' of concrete may be conservatively taken as a factor of 2.20E-03. This value is the smallest reduction factor calculated in Table 10 of Reference 2.11. This value is conservatively chosen from Reference 2.11 Table 10 since the source term (Noble Gases only) most closely approximate the external cloud source (after the 5 minute PPP) which has been processed by the SGTS or by deposition within the MSLicondenser. Therefore, the CR operator dose may be calculated by multiplying the Table 6-16 integrated external cloud whole body dose by the 2' concrete reduction factor from Table 10 of Reference 2.11. Thus, the CR operator dose from the external cloud is:

10 External cloud dose to CR Operators - Calculation Results:

CR Operator Dose (External Cloud) = 6.54

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

136 1

1 Table 6 Maximum Unprotected CR Whole Body Dose Rate in First 24 Hours Post LOCA Release Pathway WB AD WB AD WB AD WB AD WB AD WB AD WB AD WB AD WB AD WB AD WB AD (R)

(R)

(R)

(R) @

(R)

(R)

(R)

(R)

(R)

(R)

(R)

@ 0.05 hrs

@ 0.3 hrs

@ 0.5 hrs 0.9667hrs

@ 1.8 hrs

@ 2.0 hrs

@ 2.3 hrs

@ 3.1 hrs

@ 7.5 hrs

@ 8.0 hrs

@ 24.0 hrs Primary Leak - RB 2.3714E-02 2.3088E-04 9.4444E-05 1.31V8E-04 2.4996E-06 4.5887E-13 (Attachment No. 58)

Primary Leak - Stack 0

1.3012E-04 2.2501E-04 2.2891E-03 1.0696E-02 2.4267E-0I 3.6700E-01 4.671 IE-03 1.6706E-02 9.8956E-03 (Attachment No. 76) 1 SCB - Inboard MSIV 2.1398E-06 8.1237E-06 1.0006E-04 1.5958E-03 4.2174E-03 3,2285E-02 4.7883E-02 (Attachment No. 77)

SCB -

-PCI 1.8192E-07 1.1140E-06 5.3093E-04 2.6694E-02 4,4254E-02 (Attachment No. 78) 1 SCB - RCIC 2.2058E-07 1.1782E-06 3.7299E-04 1.0332E-02 1.4156E-02 (Attachment No. 79)

MSIV Leakage 2.8678E-07 1.8067E-06 9.7529E-04 7.3955E-02 1,7064E-01 (Attachment No. 80)

ESF Leakage - RB 1.9247E-02 1.8663E-04 7.5702E-05 1.0387E-04 1.8768E-06 3.2162E-13 (Attachment No. 31)

ESF Leakage - Stack 0

8.7788E-06 1.7930E-05 8.4222E-04 6.3281E-03 1.2123E-02 (Attachment No. 33)

WB DR*

WB DR*

WB DR*

WB DR*

WB DR*

WB DR*

WB DR*

WB DR*

WB DR*

WB DR*

WB DR*

(Rfhr)

(R/hr)

(R/hr)

(R/hr) @

(R/hr)

(P/hr)

(R/hr)

(P/hb)

(R'hr)

(R/hr)

(R/hr)

@ 0,05 hrs

@ 0.3 hrs

@ 0.5 hrs 0.9667hrs

@ 1.8 hrs

@ 2.0 hrs

@ 2.3 hrs

@ 3.1 hrs

@ 7.5 hrs

@ 8.0 hrs

@ 24.0 hrs Primary Leak - RB 4.74E-01 9.24E-04 4.72E-04 8.79E-05 4.17E-07 0

Primary Leak - Stack 0

5.20E-04 1.13E-03 4.90E-03 1.28E-02 1.21 1.22 5.84E-03 3.41E-03 6.18E-04 SCB - Inboard MSIV 7.13E-06 4.06E-05 2.14E-04 1.06E-03 3.83E-03 6.59E-03 2.99E-03 SCB - HPCI 6.06E-07 5.57E-06 3.54E-04 4.45E-03 2.77E-03 SCB - RCIC 7.35E-07 5.89E-06 2.49E-04 1.72E-03 8.85E-04 MSIV Leakage 9.56E-07 9.03E-06 6.50E-04 1,23E-02 1.07E-02 ESF Leakage - RB 3.85E-01 7,47E-04 3.79E-04 6.92E-05 3.13E-07 0

ESF Leakage - Stack 0

3.51E-05 8.97E-05 5.61E-04 1.05E-03 8.91E-04 Totals 8.59E-01 2.24E-03 2.13E-03 1.21 1.22 2.95E-02 1.89E-02 Whole Body Dose Rate equals the Delta Dose from RADTRAD outputs divided by the Delta Time in those RADTRAD outputs.

CAROLINA POWER & LIGHT COMPANY BRUNSWICK NUCLEAR PLANT Calculation No.

BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

137 1

3. Direct radiation shine from post-LOCA source within the RB to CR and TSC operators when within the CR/TSC Buildings:

Direct RB Shine Dose to CR Operators - Inputs & Results:

From Reference 2.11 Section 7.1, the 30 day integrated dose to the CR operators resulting from direct shine from the contained LOCA source within the RB is 3.559E-01 Rem TEDE.

Direct RB Shine Dose to TSC Operators - Inputs and Results:

From Reference 2.11 Section 7.1, the 30 day integrated dose to the TSC operators resulting from direct shine from the contained LOCA source within the RB is 3.559E-01 Rem TEDE.

4. Direct radiation shine dose to CRiTSC operators from post-LOCA source within the SGTS filters:

Direct SGTS Filter Shine Dose to CR Operators - Inputs & Results:

From Reference 2.25 Section 7.2, the 30 day integrated dose to the CR operators resulting from direct shine from the SGTS filters within the RB is 1.796E-01 Rem TEDE.

Direct SGTS Filter Shine Dose to TSC Operators - Inputs and Results:

From Reference 2.25 Section 7.2, the 30 day integrated dose to the TSC operators resulting from direct shine from the SGTS filters within the RB is 1.796E-01 Rem TEDE (CR operator dose from the SGTS filters considered bounding for the TSC operators).

5. Direct radiation shine dose to CR/TSC operators from post-LOCA source within the CRITSC filters:

Direct CR Filter Shine Dose to CR Operators - Inputs & Results:

From Reference 2.25 Section 7.2, the 30 day integrated dose to the CR operators resulting from direct shine from the CR safety filters within the Control Building is 7.11 IE-01 Rem TEDE.

Direct TSC Filter Shine Dose to TSC Operators - Inputs and Results:

From Reference 2.25 Section 7.2, the 30 day integrated dose to the TSC operators resulting from direct shine from the TSC safety filters within the TSC Structure is 9.777E-02 Rem TEDE.

I

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

144 1

The Case 2, Primary Leakage from Stack, Attachment No. 61 RADTRAD model is modified to reflect the reduced Primary Leakage with the following changes. These changes affect RADTRAD Pathways 1 - 7 in Attachment No. 61 and correspond with the pathway previously developed in calculation section 6.2.7.

6.21.1 RADTRAD Pathway 1 represents the 0.4559% Primary Containment Leakage Term:

1. The Primary Containment leakage rate equals 0.5% per day (DI 4.14). The 0.5%/day by weight primary leakage term addresses all leakage from the Primary Containment (with the exception of leakage past the MSIVs) including leakage which bypasses the Secondary Containment. The Case 2 RADTRAD model addresses only the Primary Containment Leakage that does not bypass the Secondary Containment. Furthermore, Case 2 addresses the Primary Containment Leakage term only following the PPP.

Primary Containment Leakage during the PPP is addressed as Case 1. Secondary Containment Bypass is addressed as Cases 3 through 6. MSIV Leakage is addressed as Cases 7 & 8.

2. PPP duration equals 5 minutes (actual RADTRAD model input for the PPP is 5 minutes minus the 2 minute time to onset of release, DI 4.5, or 3 minutes)
3. Use RADTRAD filtered pathway. Zero cfm flow for the first 3 minutes (0.05 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />), as the Primary Leakage before this period is addressed in Case 1. After 0.05 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />, filtered Primary Leakage is 0.51922 cfm (flow rate equivalent to 0.4559 %/day Primary Leakage previously evaluated in calculation section 6.1.7 item 2). SGTS filter removal efficiencies are 99.99% for aerosols, 99% for elemental iodines, and 99% for organic iodines (DI 4.22) for Rev. 0 of this calculation. However, for Rev. 1, the SGTS aerosol removal efficiency is reduced to 99% (See Ref. 2.6). This results in Rev. 1 to Attachments 76 and
81. Primary Leakage is reduced by a factor of 2 or 50% at 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> post-LOCA (DI 4.15).

The lKi{i whicn confirms that the Primary Leakage is less wian 0.5%/day is performed at a pressure of 49 psig (DI 4.16). Per Calculation Assumption 3.3, the conservative post LOCA DW pressure considering combustible gas control is 31 psig from 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to 30 days. Thus, the DW pressure 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> post-LOCA is a factor of (49 psid / 31 psid), 1.58 lower than design ILRT test pressure. From Reference 2.19 equation 3.20, flow is a function of the square root of delta pressure. If the reduction in DW AP is a factor of 1.58

[(49 psig - 14.7 psia) / (31 psig - 14.7 psia)], then the reduction in flow is a factor of the square root of 1.58, or 1.26 (i.e., reduced flow is (1 / 1.26) or approximately, 80% of base flow rate).

Therefore, at 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> post-LOCA, the Primary Leakage flow rate is reduced by a factor of 0.80 to 0.41538 cfm, which continues for the duration of the accident. SGTS filter efficiencies remained unchanged from those given above.

4. No additional inputs used.

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

157 1

1 Table 6 BNP Final LOCA Dose Summary - Alternate Pathway - Without DW Sprays - Revised Leak Rate Sin le Failure of Valve F021 Within Primary Pathway BNP LOCA Pathway - Worst Case Description EAB Dose LPZ Dose CR Dose - Rem TEDE (Att. No.)

TSC Dose - Rem TEDE (Att. No.)

(Rem (Rem 0 cfm 3000 cfm 10000 cfm 0 cfm 1720 cfm 10000 cfm TEDE)

TEDE)

Inleakage Inleakage Inleakage Inleakage Inleakage Inleakage 10000 cfm 10000 cfm Primary Leakage from RB Wall (ppprb5_10000cfm 0.1084 0.0383 0.1845 0.1783 0.1807 0.0138

_nospray. 1,vol newleak-cr20 / tscl20)

(58)

(58)

(60)

(59)

(58)

(69)

Primary Leakage from Stack (pppst5_lpt8_10000cfm 0.1644 0.1107 0.1855 0.1216

_nospray-lvol-newleak_p-cr20/tscl2O)

(76)

(76)

(76)

(81)

Secondary Cont. Bypass - Inboard MSIV (scbmslalternate 0.0339 0.1585 0.2262 0.0348 10000cfm-nospray-i vol-newleak cr20 / tsc 120)

(77)

(77)

(77)

(82)

Secondary Cont. Bypass - HPCI (hpci-alternate_10000cfm 0.0325 0.1503 0.2194 0.0337

_nospray 1vol-newleak cr20 / tsc 120)

(78)

(78)

(78)

(83)

Secondary Cont. Bypass - RCIC (rcicalternate_10000cfm 0.0099 0.0469 0.0670 0.0103

_nosprayl vol-newleak-cr20 /tsc 120)

(79)

(79)

(79)

(84)

MSIV Leakage - (msiv.alternate_10000cfm 0.1627 0.7302 1.1339 0.1738

_nospray-I volnewleak.cr20 / tsc 120)

(80)

(80)

(80)

(85)

ESF Leakage from RB Wall (esfrb5_10000cfmcr20" 0.0808 0.0286 0.1356 0.1312 0.1331 0.0097 0.0098 0.0102 tscl20)

(31)

(31)

(30)

(12)

(31)

(52)

(53)

(54)

ESF Leakage from Stack (esfst5_lOOOOcfm-cr20 / tscl20) 0.0531 0.0924 0.0181 0.0917 0.1191 0.0165' 0.0369 0.0685 (33)

(33)

(32)

(13)

(33)

(55)

(56)

(57)

Totals:

0.6457 1.3559 2.2649 0.4667

CAROLINA POWER & LIGHT COMPANY BRUNSWICK NUCLEAR PLANT Calculation No.

IBNP-RAD-007 Cacuato CALCULATION SHEET Page No.

Rev.

159 1

RB for the period from model time equal zero to 0.05 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.

2. After 0.05 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />, the SGTS has established a negative 0.25 Inch WG pressure in the RB. The minimum SGTS exhaust rate for the remainder of the LOCA event is 2700 cfm per DI 4.21.
3. The SGTS filter removal rates (after 0.05 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />) are modeled as 99.99% for aerosols, 99% for elemental iodines, and 99% for organic lodines. This input has no impact on the RB inventories and therefore was not modified for Rev. 1 of this calculation.
4. No additional inputs used.

6.22.6 RADTRAD Source Term:

1. Same Source Term as previously developed in calculation section 6.1.15.

6.22.7 RADTRAD Control Options:

1. The following supplemental time steps are selected to provide a sufficient time history profile of the RB inventories.

Time (hours)

Time Step (hours) 0.0 0.50 2.0 2.0 4.0 4.0 16.0 8.0 24.0 12.0 48.0 24.0 240.0 120.0 720.0 RB inventory results of this RADTRAD run are contained in Attachment No. 86. The actual RB inventory activity (RADTRAD file stripped of extraneous information) is provided as Attachment No. 87.

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

162 1

6.24 Post LOCA Integrated Activity in the Environment:

For the BNP UFSAR, the post-LOCA integrated activity release to the Environment needs to be calculated. This activity is determined using the previously developed RADTRAD models from calculation sections 6.1, 6.2, 6.11, 6.12, 6.13, 6.14, 6.9, and 6.10 and as modified per calculation section 6.19 to remove DW sprays and calculation section 6.21 to revise the Primary Leakage flow rates. These cases (Case Nos. 1, 2, 11, 12, 13, 14, 9, &

10) comprise the bounding Alternate Pathway RADTRAD models as summarized in Tables 6-15, 6-18, 6-19, & 6-20. Attachment models adjusted as defined below are 58, 76, 77, 78, 79, 80, 31, & 33, respectively.

These models are each modified as follows:

1. Print volume detail for the Environment Volume.
2. Zero (1.OE-20) the CR outside air intake, CR outside air inleakage, and CR exhaust flows. Zero all CR filter removal efficiencies.
3. Add supplemental time steps within RADTRAD Options.
4. For Attachment 91, primary containment leakage released via SGTS, the aerosol removal efficiency for Pathway 1 was changed to 99% in Rev. 1 of this calculation.

The results of these RADTRAD runs are included as Attachment Nos. 90 - 97. Post LOCA integrated activity in the Environment may be determined by summing the isotopic activity at each of the output time periods from each case. This step is performed within the EXCEL spreadsheet provided as Attachment No. 98. Column J of the spreadsheet is equal to the sum of the values in Columns B through I for each nuclide. For example, for 1 131 activity released at 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:

1.9E0 + 3.7E1 + 4.9E-3 + 1.14E-3 + 7.7E-4 + 2E-3 + 1.85E0 + 4.05E1 = 8.13E1 Note that the isotopic activity calculated by RADTRAD within the Environment Volume does not reflect radioactive decay. Thus, the activity shown in the RADTRAD output files in the Environment Volume is actually the integrated activity released to the Environment.

A parametric model was developed from scratch for the Primary Leakage case during the PPP without the CR volume and associated flow paths. This parametric model was developed to ensure that the introduction of the 1.OE-20 flow rates placed in the Control Room pathways do not introduce errors or instabilities into the RADTRAD results.

Evaluated activity (Curies) in the RADTRAD Environment volume is essentially identical in each model. This parametric file is not included with this calculation.

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

163 1

7.0

SUMMARY

AND CONCLUSIONS:

Table 7-22 provides a cross-reference summary of all RADTRAD file names versus a case description.

7.1 Final BNP LOCA Dose Summary - Bounding Case (Alternate Pathway):

As documented in calculation section 6.15 and Tables 6-14 and 6-15, the "worst case" single failure is failure of valve MVD-F021 in the Primary Pathway. MSIV and SCB releases are then directed to the condenser via the Alternate Pathway. This conclusion is based on RADTRAD CR dose models with 3000 cfm unfiltered inleakage.

As documented in calculation section 6.20 and Table 6-18, the "worst case" CR/TSC unfiltered inleakage with respect to CR/TSC operator dose is 10,000 cfm for the internal cloud dose contribution.

As documented in calculation section 6.20 and Tables 6-18 & 6-19, as anticipated, the "no spray" offsite and CR/TSC operator internal cloud doses bound the "spray" case.

As documented in calculation section 6.21 and Table 6-20, the final and bounding offsite and CR/TSC internal cloud doses are based on the Alternate Pathway, no DW Sprays, and a revised Primary Leakage rate after 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (based on 31 psig long term pressure resulting from Combustible Gas Control). Thus, the CR/TSC operator "shine" doses from calculation section 6.19 are also based on the section 6.21 and Table 6-20 dose models and resultant doses. The calculation section 6.19 "shine" doses need to be added to the Table 6-20 CR/TSC operator internal cloud dose in order to arrive at a total CR/TSC operator dose. Ingress/egress dose is not included in this dose summary, given below in Table 6-21.

Bounding offsite and site doses are summarized below:

Table 6 Summary of LOCA Doses Release Pathway EAB LPZ CR TSC (Rem TEDE)

(Rem TEDE)

(Rem TEDE)

(Rem TEDE)

Primary Containment Leakage 0.27 0.15 0.37 0.14 Secondary Containment Bypass 0.08 0.36 0.51 0.08 ESF Leakage 0.13 0.12 0.25 0.08 MSIV Leakage 0.16 0.73 1.13 0.17 External Cloud 0.01 0.04 RB Direct Shine 0.36 0.36 SGTS Filter Direct Shine 0.18 0.18 CR/TSC Filter Direct Shine 0.71 0.10 ECCS Piping Shine 0.10 Neg.

Totals 0.64 1.36 3.62 1.15 Regulatory Limit 25 25 5

5

CAROLINA POWER & LIGHT COMPANY BRUNSWICK NUCLEAR PLANT CALCULATION SHEET Calculation No.

BNP-RAD-007 Page No.

167 1

PPPST5-lpt8-lOOOOcfm-NoSpraylVol-New~eak pR20 SCBMSL Alternate-lOOO0cfm iNoSpray-I Vol NeWLeak CR20 HIPCI Alternate 1006O0cfm NoSprayAlVol NeWLeak CR20 RCIC-Alternate 1OOO0cfmnNoSpray-1 Vol NewLeak CR20 MSIV Alternate lOOO0cfm NoSprayi Vol New~eak CR20 PPPST5 1 pt8-lOOOOcfm-NoSprayA Vol-New~eak p TSC 120 SCBMSL Alternate 1 OOO0cfm NoSprayJ Vol NewLeak TSC 120 HIPCL Alternate 1OOO0cfm NoSprayAlVol-NewLeak TSC120 RCLC Alternate lOOO0cfm NoSpray-lVol-NewLeak TSC 120 MSIV Alternate lOOO0cfm NoSpray-1Vol NeWLeak TSC120 PLKG RBInv ESFLKG RBInv PPPRB 5_NoSpray EnvrAct PPPST5_ýNoSpray pA EnvrAct SCBMSL AlternateNoSpray-iinvrAct HIPCI Alternate NoS pray-EnvrAct MSIVAlternate NoSprayj~nvrAct I95 ESFRB5 EnvrAct 96 Rev 76 77 78


79 8i I

- 81 83 86 88 i

+/-

91

+/-

92

-I 93

-t 94 92 93 94 v/

WQT71Q'U"ý PnwrAt-f I

I i

i I

77 78 79 80 81 82 83 Z54 85 88 90 I

91

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

2-8 FDesign Calculation BNP-RAD-007 Revision 1 The signature below of the Lead Reviewer records that:

the review indicated below has been performed by the Lead Reviewer; appropriate reviews were performed and errors/deficiencies (for all reviews performed) h~ave been resolved and these records are included in the design package; the review was performed in accordance with EGR-NGGC-0003.

IlDesign Verification Review 0]

Engineering Review Owner Review El Design Review El Alternate Calculation El Qualification Testing 0I Special Engineering Review E] YES El N/A Other Records are attached.

Engineering 3,OZ-"

Lead Reviewer, (pri sign)

Discipline Date Item No.

Deficiency Resolution/Date In the revision summary for Rev. 1 (page v),

Incorporated 4/19/02 1

3rd line from bottom, typo CR/TSC vice CR?TSC.

On page 144, section 6.21.1.3, suggest for Incorporated 4/19/02 2

clarity that the clarification about particulate efficicency be placed immediately following the "99.99% for aerosols" (in middle of page rather than at the end of the section).

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 3, Page 3-3 Figure 2 - LOCA (Primary Leakage via SGTS Exhaust to Stack) - RADTRAD Model LOCA Time Line:

Time =

-2 Minutes Time =

0 Minutes Time =

0 - 3 Minutes Time =

3 Min - 30 Day LOCA Start, SGTS Drawdown Process Begins Begin LOCA Source Release (Gap Release 0 - 0.5 Hours, EIV Release 0.5 - 2 Hours)

No Primary Leakage Release via SGTS/Stack to the Environment, SGTS Drawdown Ends Primary Leakage via SGTS/Stack to the Environment, 99/99/99% Filter Removal Efficiencies

.7 Volume 2 Unsprayed DV 78,836 Ft3 48.07% Source 95% Aerosol 4.85% Elem.

0.15% Org.

Natural Dep.:

10th Percentile Volume 1 Sprayed DW 85,164 Ft3 51.93% Source:

95% Aerosol 4.85% Elem.

0.15% Org.

Natural Dep.:

10'j Percentile Sprays:

10t Percentile 51.93% Cover FP 31 Primary Leakage:

0.51922 cfm equal to 0.4559 %/day e:

filtered, (99/99/99)

FP 2 FP I & 2 - 200%/hour of Unsprayed Volume Volume 3 Environment IFP4 4 CR Outside Air*Intake:

Normal flow, 2100 cfm, unfiltered Emerg. flow, 1500 cfm, filtered (95/90/90)

CR Outside Air Inleakage:

3000 cfm, unfiltered F7P 67 CR Air Exhaust:

Normal flow, 5100 cfm, unfiltered Emerg. flow, 4500 cfm, unfiltered Volume 4 BNP CR 298,650 Ft3 Filtered Recirculation Flow:

400 cfm 95/90/90 Filter Removal r

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

76-1 1

Attachment No. 76 RADTRAD Case 2 with 10,000 cfm CR Inleakage, No Sprays, Revised Primary Leak

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76 - 2 ft########it###

            1. f################################it###ft#######t############

RADTRAD Version 3.02 run on 4/02/2002 at 11:16:17

                                  1. it#####ft####################ft###########################

File information

              1. it###############################################i##################

Plant file name C:\\RADTRAD V3.02\\Accept\\pppst5_ipt81OOOOcfm nosprayIvolnewleak-p-cr2O.psf" Inventory file name

= c:\\radtrad v3.02\\defaults\\bnploca.nif Scenario file name

= C:\\RADTRAD V3.02\\Accept\\pppst5_lpt8_10000cfm nosprayjivolnewleak-p-cr2O.psf Release file name

- c:\\radtrad v3.02\\defaults\\bnploca.rft Dose conversion file name = c:\\radtrad v3.02\\defaults\\fgrll&12.inp

  1. t
  1. t
  1. t
  1. t
      1. j it
        1. titi iti it it iti it# it it #t it #####i it #
  1. i ft#

it #

it# it it #

it it

  1. t ft it
  1. t
          1. iti it it
  1. t it it it ft it
        1. ti
  1. t Radtrad 3.02 1/5/2000 BNP - Primary Leakage via SGTS & Stac]

Nuclide Inventory File:

c:\\radtrad v3.02\\defaults\\bnploca.nif Plant Power Level:

2.9810E+03 Compartments:

3 Compartment 1:

BNP Drywell 3

1.6400E+05 0

0 0

1 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

k after PPP - No Sprays -

1 Volume

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76 - 3 BNP Control Room 1

2.9865E+05 0

0 1

0 0

Pathways:

4 Pathway 1:

BNP Drywell 1

2 2

Pathway 2:

Environment 2

3 2

Pathway 3:

Environment 2

3 2

Pathway 4:

BNP Control 3

2 2

to Environment to BNP Control Room - Normal/Emergency Outside Air Intake to BNP Control Room - Normal/Emergency Outside Air Inleakage A

Room to Environment -

CR Exhaust End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1

1.OOOOE+00 c:\\radtrad v3.02\\defaults\\fgrll&12.inp c:\\radtrad v3.02\\defaults\\bnploca.rft 0.0000E+00 1

9.5000E-01 4.8500E-02 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

1.5000E-03 1.OOOOE+00

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76 - 4 0

0 0

3 3

1. OOOOE+01 0

Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

0 1

0 0

0 0

1 4.0000E+02 3

0.OOOOE+00 3.OOOOE-01 7.2000E+02 0

0 Pathways:

4 Pathway 1:

0 0

0 0

0 1

4 0.OOOOE+00 5.OOOOE-02 2.4000E+01 7.2000E+02 0

0 0

0 0

0 Pathway 2:

0 0

0 0

At 0.OOOOE+00

9. 5000E+01 0.OOOOE+00 0.OOOOE+00 5.1920E-01 4.1540E-01 0.OOOOE+00 0.OOOOE+00
9. OOOOE+01 0.OOOOE+00 0.OOOOE+00 9.9000E+01 9.9000E+01 0.OOOOE+00 0.OOOOE+00
9. OOOOE+01 0.OOOOE+00 0.OOOOE+00 9.9000E+01
9. 9000E+01 0.OOOOE+00 0.OOOOE+00
9. 9000E+01
9. 9000E+01 0.OOOOE+00

Calculation No. BNP-RAD-007 Revision I Attachment No. 76 0

1 3

o.OOOOE+O0 3.OOOOE-01

7. 2000E+02 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 0 0000E+00

7. 2000E+02 0

0 0

0 0

0 Pathway 4:

0 0

0 0

0 1

3

0. OOOOE+00 3.OOOOE-01
7. 2000E+02 0

0 0

0 0

0 2.1000E+/-03

1. 5000E+03
0. OOOOE+00
1. OOOOE+/-04
0. OOOOE+00
0. OOOOE+00
9. 5000E+01
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00 9.OOOOE+01 0.OOOOE+00
0. OOOOE+00 0.OOOOE-i00
0. OOOOE+00 9. OOOOE+01
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00 A
1. 2100E+04
1. 1500E+04
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00 0.OOOOE+00
0. OOOOE+00
0. OOOOE+/-00
0. OOOOE+/-00
0. OOOOE+00
0. OOOOE+00 Dose Locations:

4 Location 1:

BNP EAB 2

1 4

0.OOOOE+00 1.8000OE+00

2. 3000E+00
7. 2000E+I02 1

3.6300E 06 5.8500E 05 3.6300E 06

0. OOOOE+00 Page 76 - 5

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 4

0.000OE+00 8.000OE+00 2.4000E+01 7.2000E+02 0

Location 2:

BNP LPZ 2

1 7

0 OOOOE+00

1. 8000E+00 2.3000E+00
8. OOOOE+00 2.4000E+01
9. 6000E+01 7.2000E+02 1

4 0.OOOOE+00 8.OOOOE+00 2.4000E+01 7.2000E+02 0

Location BNP CR 3

0 3:

1 2

0.OOOOE+00 7.2000E+02 1

4 0.OOOOE+00 2. 4000E+01 9.6000E+01 7.2000E+02 3.5000E-04 1.8000E-04 2.3000E-04 0.OOOOE+00 3.5000E-06 1.8800E-05 1.9200E-06 1.4200E-06 7.4000E-07 3.0700E-07 0.OOOOE+00 3.5000E-04 1.8000E-04 2.3000E-04 0.OOOOE+00 A

3.5000E-04 0.OOOOE+00 1.OOOOE+00 6.OOOOE-01

4. OOOOE-01 0.OOOOE+00 Location 4:

BNP CR - Unprotected Dose 2

1 7

0.OOOOE+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01

9. 6000E+01 7.2000E+02 1

4 0.000OE+00 9.6670E-01 3.1000E+00 7.2000E+02 4.6500E-06 3.1900E-04 1.7300E-06 1.0600E-06 3.6200E-07 7.7600E-08 0.OOOOE+00 3.5000E-04 3.5000E-04 3.5000E-04 0.OOOOE+00 Page 76 - 6

Calculation No. BNP-RAD-007 Revision 1 0

Effective Volume Location:

1 7

0.0000E+00 4.6500E-06 1.8000E+00 3.1900E-04 2.3000E+00 1.7300E-06 8.0000E+00 1.0600E-06 2.4000E+01 3.6200E-07 9.6000E+01 7.7600E-08 7.2000E+02 0.OOOOE+00 Simulation Parameters:

1 0.OOOOE+00 0.OOOOE+00 Output Filename:

C:\\RADTRAD V3.o21 1

1 1

1 0

End of Scenario File Attachment No. 76 Page 76 - 7 A

Calculation No. BNP-RAD-007 Revision 1 A0 Attachment No. 76 Page 76 - 8

Calculation No. BNP-RAD-007 Revision I Attachment No. 76 rage 7o RADTRAD Version 3.02 run on 4/02/2002 at 11:16:17 Plant Description Number of Nuclides 60 Inventory Power :

1.0000E+00 MWth Plant Power Level 2.9810E+03 MWth Number of compartments Compartment information

=

3 Compartment number 1

(Source term fraction =

1.O000E+00 Name: BNP Drywell Compartment volume 1

1.6400E+05 (Cubic feet)

Removal devices within compartment:

Deposition Pathways into anc out of compartment 1

Pathway to compartment number 2: BNP Drywell to Environment Compartment number 2

Name: Environment Pathways into and out of compartment 2

Pathway to compartment number 3: Environment Pathway to compartment number 3: Environment Pathway from compartment number 1: BNP Drywell Pathway from compartment number 3: BNP Control Compartment number 3

Name:

BNP Control Room Compartment volume =

2.9865E+05 (Cubic feet)

Removal devices within compartment:

Filter(s)

Pathways into and out of compartment 3

Pathway to compartment number 2: BNP Control Pathway from compartment number 2: Environment Pathway from compartment number 2: Environment to BNP Control Room -

Normal to BNP Control Room -

Normal to Environment Room to Environment -

CR Exh Room to Environment to BNP Control Room to BNP Control Room CR Exh Normal Normal Total number of pathways =

4

-9

Calculation No. BNP-RAD-007 Revision I Attachment No. 76 Page 76 - 10 RADTRAD Version 3.02 run on 4/02/2002 at 11:16:17 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled RELEASENAME = BWR, NUREG/CR-6604, Table 3.1 Release Fractions and Timings NOBLES IODINE CESIUM TELLURIUM STRONTIUM BARIUM RUTHENIUM CERIUM LANTHANUM GAP 0.5000 hrs

5. OOOOE-02
5. OOOOE-02 5.OOOOE-02 0 OOOOE+00 0 OOOOE+00
0. 0000E+00 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 Iodine fractions Aerosol Elemental Organic COMPARTMENT DATA EARLY IN-VESSEL 1.5000 hrs
9. 5000E-01 2.5000E-01
2. OOOOE-01
5. OOOOE-02
2. OOOOE-02
2. OOOOE-02
2. 5000E-03 5.OOOOE-04 2.OOOOE-04
9. 5000E-01 4.8500E-02 1.5000E-03 Compartment number 1: BNP Drywell Natural Deposition (Powers' model):

Aerosol data Reactor type:

3 Percentile

=

10 (%)

Compartment number 2: Environment Compartment number 3: BNP Control Room Compartment Filter Data Time (hr) 0.OOOOE+00 3.OOOOE-01 7.2000E+02 Flow Rate (cfm) 4.OOOOE+02 4.OOOOE+02 4.OOOOE+02 Filter Aerosol 0.OOOOE+00 9.5000E+01 0.OOOOE+00 Efficiencies Elemental 0.OOOOE+00 9.OOOOE+01 0.0000E+00 M%)

Organic 0.OOOOE+00

9. OOOOE+01 O.O000OE+00 PATHWAY DATA Pathway number 1: BNP Drywell to Environment Pathway Filter:

Removal Data Time (hr)

Flow Rate (cfm)

Filter Efficiencies

(%)

Aerosol Elemental Organic

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76 - 11 o.OOOOE+00 5.0000E-02 2.4000E+01 7.2000E+02 0.0000E+00 5.1920E-01

4. 1540E-01 0.000OE+00 0.0000E+00
9. 9000E+01
9. 9000E+01 0.0000E+00 0.OOOOE+00
9. 9000E+01
9. 9000E+01 0.OOOOE+00 0.OOOOE+00
9. 9000E+01 9.9000E+01 0.OOOOE+00 Pathway number 2: Environment to BNP Control Room -

Normal Pathway Filter:

Removal Data Time (hr) 0.0000E+00 3.OOOOE-01 7.2000E+02 Flow Rate (cfm)

2. 1000E+03 1.5000E+03 0.OOOOE+00 Filter Efficiencies

(%)

Aerosol Elemental Organic 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 9.5000E+01 9.OOOOE+01 9.OOOOE+01 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 3: Environment to BNP Control Room -

Normal Pathway Filter:

Removal Data Time (hr) 0.OOOOE+00 7.2000E+02 Flow Rate (cfm) 1.0000E+04 O.OOOOE+00 Filter Efficiencies (%)

Aerosol Elemental Organic 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number i: BNP Control Room to Environment -

CR Exh Pathway Filter:

Removal Data Time (hr) 0.OOOOE+00 3.OOOOE-01 7.2000E+02 Flow Rate (cfm) 1.2100E+04 1.1500E+04 0.OOOOE+00 Filter Efficiencies

(%)

Aerosol Elemental Organic 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 LOCATION DATA Location BNP EAB Location X/Q Data Time (hr) 0.OOOOE+00 1.8000E+00 2.3000E+00 7.2000E+02 is in compartment X/Q (s

  • m^-3) 3.6300E-06 5.8500E-05 3.6300E-06 O.OOOOE+00 Location Breathing Rate Data Time (hr)

Breathing Rate (m^3

  • sec^-1) 0.OOOOE+00 3.5000E-04 8.OOOOE+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.OOOOE+00 Location BNP LPZ is in compartment 2

Location X/Q Data Time (hr) 0.OOOOE+00 1.8000E+00 2.3000E+00 X/Q (s

  • m--3) 3.5000E-06 1.8800E-05 1.9200E-06 2

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76 - 12 8.OOOOE+00 2.4000E+01

9. 6000E+01 7.2000E+02 Location Breathing Time (hr) 0.OOOOE+00 8.OOOOE+00 2.4000E+01 7.2000E+02 Location BNP CR Location X/Q Data Time (hr)

O.O000E+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01 9.6000E+01 7.2000E+02 Location Breathing Time (hr),

0.OOOOE+00 7.2000E+02 1.4200E-06 7.4000E-07 3.0700E-07 0.OOOOE+00 Rate Data Breathing Rate (m^3

  • sec^-1) 3.5000E-04 1.8000E-04 2.3000E-04 0.OOOOE+00 is in compartment 3

X/Q (s

  • m^-3) 4.6500E-06
3. 1900E-04 1.7300E-06 1.0600E-06 3.6200E-07 7.7600E-08 0.OOOOE+00 Rate Data Breathing Rate (m^3
  • sec^-1) 3.5000E-04 0.OOOOE+00 Location Occupancy Factor Data Time (hr)

Occupancy Factor 0.OOOOE+00 1.OOOOE+00 2.4000E+01 6.OOOOE-01 9.6000E+01 4.OOOOE-01 7.2000E+02 0.OOOOE+00 Location BNP CR - Unprotected Dose Location X/Q Data Time (hr) 0.OOOOE+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01 9.6000E+01 7.2000E+02 is in compartment 2

X/Q (s

  • m^-3)
4. 6500E-06 3.1900E-04 1.7300E-06
1. 0600E-06
3. 6200E-07
7. 7600E-08 0.000OE+00 Location Breathing Rate Data Time (hr)

Breathing Rate (m^3

  • sec-1) 0.OOOOE+00 3.5000E-04 9.6670E-01 3.5000E-04 3.1000E+00 3.5000E-04 7.2000E+02 0.OOOOE+00 USER SPECIFIED TIME STEP DATA -

SUPPLEMENTAL TIME STEPS Time Time step 0.OOOOE+00 0.OOOOE+00

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76 - 13 RADTRAD Version 3.02 run on 4/02/2002 at 11:16:17 4

  1. 4#

4 4

4 #

4 4 #

4 4 #

4

  1. 4 #

4 44#

4 4

4####

4 4

4#############4##4#4############4###4##4###################4###########

Dose Output BNP EAB Doses:

Time (h)

=

0.0ý00 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.0OOE+00 0.OOOOE+00 TEDE 0.0000E+00 0.OOOOE+00 BNP LPZ Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body o.OOOOE+00 0.OOOOE+00 Thyroid 0.OOOOE+00 0.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP CR Doses:

Time (h) 0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.0000E+00 0.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP CR - Unprotected Dose Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.OOOOE+00 0.OOOOE+00 TEDE 0.OOOOE+00 O.OOOOE+00 BNP EAB Doses:

Time (h)

=

0.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.0158E-04 1.0158E-04 Thyroid 1.2317E-03 1.2317E-03 TEDE 1.5271E-04 1.5271E-04 BNP LPZ Doses:

Time (h)

=

0.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 9.7940E-05 9.7940E-05 Thyroid 1.1876E-03 1.1876E-03 TEDE 1.4724E-04 1.4724E-04

Calculation No. BNP-RAD-007 Revision I Attachment No. 76 Page 76 - 14 BNP CR Doses:

Time (h)

=

0.3 Delta dose (rem)

Accumulated dose 000 Whole Body 1.5918E-06 (rem) 1.5918E-06 Thyroid 3.2723E 3.2723E

-04

-04 TEDE 1.5179E-05

1. 5179E-05 BNP CR - Unprotected Dose Doses:

Time (h)

=

0.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3012E-04 1.3012E-04 Thyroid 1.5779E

1. 5779E-03

.03 TEDE 1.9562E-04 1.9562E-04 BNP EAB Doses:

Time (h)

=

Delta dose (i Accumulated c 0.5000 Whole Body rem) 1.7565E-04 lose (rem) 2.7723E-04 Thyroid 2.0904E-03 3.3221E-03 TEDE 2.6234E-04

4. 1505E-04 BNP LPZ Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.6936E-04 2.6730E-04 Thyroid 2.0155E-03 3.2032E-03 TEDE 2.5295E-04

4. 0019E-04 BNP CR Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.8304E-06 6.4222E-06 Thyroid 9.2140E-04 1.2486E-03 TEDE 4.3058E-05 5.8237E-05 BNP CR - Unprotected Dose Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.2501E-04 3.5513E-04 Thyroid

2. 6778E
4. 2556E-03

.03 TEDE 3.3606E-04 5.3168E-04 BNP EAB Doses:

Time (h)

=

0.9 Delta dose (rem)

Accumulated dose BNP LPZ Doses:

667 Whole Body 1.7870E-03 (rem) 2.0642E-03 Time (h) =

0.9667 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.7230E-03 1.9903E-03 Thyroid 1.IllOE-02 1.4432E-02 Thyroid 1.0712E-02 1.3915E-02 TEDE 2.3273E-03 2.7424E-03 TEDE 2.2440E-03 2.6442E-03 BNP CR Doses:

Time (h)

=

0.9667 Delta dose (rem)

Accumulated dose (rem)

Whole Body 5.1615E-05 5.8038E-05 Thyroid 5.9231E-03 7.1717E-03 TEDE 3.2245E-04 3.8068E-04 BNP CR -

Unprotected Dose Doses:

A

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76 - 15 Time (h)

=

0.9667 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.2891E-03 2.6443E-03 Thyroid 1.4231E-02 1.8487E-02 BNP EAB Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 8.3495E-03 1.0414E-02 Thyroid 4.4307E-02 5.8738E-02 BNP LPZ Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 8.0505E-03 1.0041E-02 Thyroid 4.2720E-02 5.6635E-02 BNP CR Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.9117E-04 4.4920E-04 Thyroid 3.2666E-02 3.9838E-02 BNP CR - Unprotected Dose Doses:

Time (h)

=

1.8ý00 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.0696E-02 1.3340E-02 Thyroid 5.6756E-02 7.5243E-02 TEDE 1.3706E-02 1.7219E-02 BNP EAB Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.4502E-02 5.4916E-02 Thyroid 2.3402E-01 2.9276E-01 TEDE 5.7169E-02

7. 0611E-02 BNP LPZ Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.4302E-02 2.4342E-02 Thyroid 7.5206E-02 1.3184E-01 TEDE 1.8372E-02 3.1333E-02 BNP CR Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.9175E-03 3.3667E-03 Thyroid 2.2417E-01

2. 6400E-01 TEDE 1.5035E-02 1.7499E-02 BNP CR - Unprotected Dose Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.4267E-01 2.5601E-01 Thyroid 1.2761E+00 1.3514E+00 TEDE 3.1174E-01 3.2896E-01 BNP EAB Doses:

Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.7303E-02 1.2222E-01 Thyroid 3.4170E-01

6. 3445E-01 TEDE 8.5822E-02
1. 5643E-01 TEDE 2.9813E 3.5129E

-03

-03 TEDE 1.0700E 1.3442E-02 02 TEDE 1.0317E 1.2961E-02 02 TEDE 2.0829E 2.4636E-

.03

.03

Calculation No. BNP-RAD-007 Revision I Attachment No. 76 Page 76 - 16 BNP LPZ Doses:

Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.1629E-02 4.5971E-02 Thyroid 1-0981E-01 2.4165E-01 TEDE 2.7580E-02 5. 8913E-02 BNP CR Doses:

Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.1732E-02 1.5099E-02 Thyroid 9.0885E-01

1. 1729E+00 TEDE 6.0993E-02 7.8492E-02 BNP CR - Unprotected Dose Doses:

Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.6700E-01 6.2301E-01 Thyroid 1.8633E+00

3. 2146E+00 TEDE
4. 6799E-01 7.9694E-01 BNP EAB Doses:

Time (h)

=

3.1000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 9.8012E-03 1.3202E-01 Thyroid 3.5956E-02 6.7041E-01 TEDE 1.1725E-02 1.6816E-01 BNP LPZ Doses:

Time (h)

=

3.1000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 5.1841E-03 5.1155E-02 Thyroid 1.9018E-02 2.6067E-01 TEDE 6.2015E-03 6.5115E-02 BNP CR Doses:

Time (h)

=

3.1000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.6721E-02 3.1820E-02 Thyroid

1. 3210E+00 2.4939E+00 TEDE 8.8409E-02 1.6690E-01 BNP CR - Unprotected Dose Doses:

Time (h)

=

3.1000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.6711E-03 6.2768E-01 Thyroid 1.7136E-02 3.2318E+00 TEDE 5.5878E-03 8.0253E-01 BNP EAB Doses:

Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.5054E-02 1.6707E-01 Thyroid

4. 9814E-02
7. 2022E-01 TEDE 3.7357E-02 2_0551E-01 BNP LPZ Doses:

Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.8541E-02 6.9696E-02 Thyroid 2.6348E-02 2.8702E-01 TEDE 1.9759E-02 8.4874E-02 BNP CR Doses:

Calculation No. BNP-RAD-007 Revision 1 Time (h)

=

8.0000 Whole Body Delta dose (rem) 3.5153E-03 Accumulated dose (rem) 3.5335E-02 BNP CR - Unprotected Dose Doses:

Attachment No. 76 Thyroid 2.5037E-01 2.7442E+00 Page 76 - 17 TEDE 1.7003E-02 1.8390E-01 Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.6706E-02 6.4439E-01 Thyroid 2.3741E-02 3.2555E+00 TEDE 1.7804E-02 8.2034E-01 BNP EAB Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.3888E-02 2.0096E-01 Thyroid 3.0555E-02 7.5078E-01 TEDE 3.4852E-02 2.4037E-01 BNP LPZ Doses:

Time (h) 24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3256E-02 8.2953E-02 Thyroid

1. 1953E-02 2.9897E-01 TEDE 1.3634E-02 9.8507E-02 BNP CR Doses:

Time (h)

= 24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.1834E-04 3.5954E-02 Thyroid 1.5267E-02 2.7595E+00 TEDE

1. 1040E-03 1.8501E-01 BNP CR - Unprotected Dose Doses:

Time (h)

= 24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 9.8956E-03 6.5428E-01 Thyroid 1.7349E-02 3.2728E+00 TEDE 1.0443E-02 8.3078E-01 BNP EAB Doses:

Time (h)

=

96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.1863E-02 2.3282E-01 Thyroid

1. 0194E-01
8. 5272E-01 TEDE 3.4981E-02 2.7535E-01 BNP LPZ Doses:

Time (h)

=

96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.4954E-03 8.9448E-02 Thyroid 2.0781E-02 3.1975E-01 TEDE

7. 1312E-03
1. 0564E-01 BNP CR Doses:

Time (h)

= 96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.2021E-04 3.6074E-02 Thyroid 8.1635E-03 2.7677E+00 TEDE 3.7000E-04 1.8538E-01 BNP CR - Unprotected Dose Doses:

Time (h)

=

96.0000 Whole Body Delta dose (rem) 3.1775E-03 Accumulated dose (rem) 6.5746E-01 Thyroid 1.5470E-02 3.2883E+00 TEDE 3.6508E-03

8. 3443E-01

Calculation No. BNP-RAD-007 Revision I Attachment No. 76 Page 76 - 18 BNP EAB Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 5.1558E-02 2.8438E-01 Thyroid 2.7781E-01

1. 1305E+00 TEDE
6. 0019E-02 3.3537E-01 BNP LPZ Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.3604E-03 9.3809E-02 Thyroid 2.3496E-02 3.4325E-01 TEDE 5.0760E-03 1.1071E-01 BNP CR Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.6987E-05 3.6101E-02 Thyroid 3.1227E-03 2.7708E+00 TEDE 1.2208E-04 1.8550E-01 BNP CR -

Unprotected Dose Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem) 8 839 Whole Body 1.1022E-03 6.5856E-01 Thyroid 9.0375E-03 3.2973E+00 TEDE 1.3774E-03 8.3581E-01 1-131 Summary BNP Drywell 1-131 (Curies) 4.4384E+03 3.9938E+05 2.1374E+06 3.4679E+06 7.2092E+06 9.3606E+06 1.2935E+07 1.6129E+07 1.8176E+07 2-0275E+07 1.6654E+07 1-2855E+07

9. 9884E+06 8.4800E+06
6. 6874E+06
5. 3346E+06
4. 3136E+06 3.5431E+06 2.9614E+06 2.5223E+06 2.2266E+06 2.0544E+06 1-9101E+06 1.7889E+06 Environment 1-131 (Curies) 0.OOOOE+00 0.OOOOE+00 6.3262E-01 1.7090E+00 4-7067E+00 7.3353E+00 1.3710E+01 2.2004E+01 2.9656E+01 3.6987E+01 4.7720E+01 5.6084E+01 6.2557E+01 6.6057E+01 7.0355E+01 7.3762E+01 7.6498E+01 7.8726E+01 8.0571E+01 8.2127E+01 8.3469E+01 8.4687E+01 8.5815E+01 8.6868E+01 BNP Control Room 1-131 (Curies) 0.OOOOE+00 0.OOOOE+00 1.3414E-05 2.7598E-05 6.2837E-05 9.0562E-05 1.4677E-04 2.0432E-04 2.4751E-04 9.0375E-03
1. 5894E-02
7. 8081E-03 3.8495E-03
2. 4095E-03
1. 2013E-03
6. 0626E-04 3.1188E-04
1. 6523E-04
9. 1423E-05 5.3722E-05 3.4082E-05 2.3794E-05 1.8248E-05 1.5103E-05 Time (hr) 0.001 0.050 0.300 0.500 0.800 0.967 1.267 1.567 1.800 2.000 2-300 2.600 2.900 3.100 3.400 3.700 4.000 4.300 4.600 4.900 5.200 5.500 5.800 6.100

Calculation No. BNP-RAD-007 Revision I 6.400 6.700 7.000 7.300 7.600 7.900 8.000 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 Attachment No. 76 1.6873E+06 1.6020E+06 1.5303E+06 1.4701E+06 1.4194E+06 1.3768E+06 1.3641E+06 1.3302E+06 1.3036E+06 1.2822E+06 1.2636E+06 1.2475E+06 1.2334E+06 1.2212E+06 1.2105E+06 1.0953E+06 8.3641E+05 8.0864E+04 Page 76 - 19 8.7858E+01 8.8794E+01

8. 9686E+01
9. 0540E+01
9. 1363E+01 9.2159E+01 9.2419E+01 9.3186E+01 9.3936E+01 9.4673E+01
9. 5398E+01
9. 6113E+01
9. 6820E+01
9. 7519E+01
9. 8211E+01 1.2745E+02 2.3231E+02 5.3844E+02 Cumulative Dose Summary BNP Thyroij (rem) 0.OOOOE+00 0.OOOOE+00 1.2317E-03 3.3221E-03 9.2210E-03 1.4432E-02 2.7094E-02 4.3563E-02 5.8738E-02 2.9276E-01 6.3445E-01 6.5091E-01 6.6358E-01 6.7041E-01 6.7876E-01 6.8535E-01 6.9061E-01
6. 9486E-01 6.9837E-01 7.0131E-01 7.0382E-01 7.0610E-01 7.0819E-01 7.1013E-01
7. 1195E-01 7.1367E-01
7. 1529E-01
7. 1684E-01
7. 1833E-01
7. 1976E-01 7.2022E-01 EAB TEDE (rem) 0.OOOOE+00 0.OOOOE+00 1.5271E-04 4.1505E-04 1.5613E-03 2.7424E-03
5. 7455E-03 9.7404E-03 1.3442E-02
7. 0611E-02 1.5643E-01
1. 6121E-01 1.6551E-01
1. 6816E-01
1. 7184E-01 1.7522E-01 1.7834E-01
1. 8123E-01 1.8392E-01 1.8644E-01 1.8880E-01 1.9102E-01 1.9312E-01 1.9510E-01 1.9698E-01
1. 9876E-01
2. 0045E-01
2. 0206E-01
2. 0359E-01
2. 0504E-01
2. 0551E-01 BNP LPZ Thyroid TEDE (rem)

(rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 1.1876E-03 1.4724E-04 3.2032E-03 4.0019E-04 8.8907E-03 1.5053E-03 1.3915E-02 2.6442E-03 2.6123E-02 5.5398E-03 4.2003E-02 9.3916E-03 5.6635E-02 1.2961E-02 1.3184E-01 3.1333E-02 2.4165E-01 5.8913E-02 2.5035E-01 6.1439E-02 2.5706E-01 6.3715E-02 2.6067E-01 6.5115E-02 2.6509E-01 6.7061E-02 2.6857E-01 6.8848E-02 2.7135E-01 7.0498E-02 2.7360E-01 7.2028E-02 2.7546E-01 7.3452E-02 2.7701E-01 7.4784E-02 2.7834E-01 7.6031E-02 2.7954E-01 7.7207E-02 2.8065E-01 7.8316E-02 2.8168E-01 7.9366E-02 2.8264E-01 8-0359E-02 2.8355E-01 8.1301E-02 2.8441E-01 8.2195E-02 2.8523E-01 8.3045E-02 2.8601E-01 8.3854E-02 2.8677E-01 8.4625E-02 2.8702E-01 8.4874E-02 BNP CR Thyroid (rem) 0.OOOOE+00 0.OOOOE+00 3.2723E-04 1.2486E-03 4.2355E-03 7.1717E-03 1.5388E-02 2.7607E-02 3.9838E-02

2. 6400E-01
1. 1729E+00 1.9642E+00 2.3522E+00 2.4939E+00 2.6135E+00 2.6732E+00 2.7035E+00 2.7192E+00 2.7276E+00 2.7324E+00 2.7353E+00 2.7372E+00 2.7385E+00 2.7396E+00 2.7405E+00 2. 7413E+00 2.7421E+00 2.7428E+00 2.7434E+00 2.7440E+00 2.7442E+00 TEDE (rem) 0.OOOOE+00 0.OOOOE+00 1.5179E-05
5. 8237E-05
2. 1196E-04
3. 8068E-04
8. 8488E-04
1. 6662E-03 2.4636E-03 1.7499E-02 7.8492E-02 1.3161E-01
1. 5749E-01 1.6690E-01 1.7483E-01 1.7879E-01
1. 8081E-01
1. 8187E-01
1. 8246E-01 1.8281E-01 1.8304E-01 1.8320E-01 1.8332E-01
1. 8343E-01 1.8352E-01 1.8360E-01 1.8368E-01
1. 8375E-01 1.8382E-01 1.8388E-01 1.8390E-01 1.3199E-05
1. 1961E-05
1. 1097E-05 1.0457E-05 9.9620E-06 9.5660E-06 9.4512E-06 7.3939E-06 6.3269E-06 5.7581E-06 5.439'E-06 5.2488E-06
5. 1249E-06 5.0377E-06
4. 9718E-06 4.4344E-06 9.2516E-07
1. 9174E-08 Time (hr) 0.001 0.050 0.300 0.500 0.800 0.967 1.267 1.567 1.800 2.000 2.300 2.600 2.900 3.100 3.400 3.700 4.000 4.300 4.600 4.900 5.200 5.500 5.800 6.100 6.400 6.700 7.000 7.300 7.600 7.900 8.000

Calculation No. BNP-RAD-007 Revision 1 7.2093E-01 7.2162E-01 7.2229E-01 7.2295E-01 7.2360E-01 7.2424E-01 7.2488E-01 7.2550E-01 7.5078E-01

8. 5272E-01
1. 1305E+00
2. 0686E-01
2. 0815E-01
2. 0938E-01
2. 1055E-01
2. 1168E-01
2. 1277E-01
2. 1381E-01
2. 1481E-01 2.4037E-01 2.7535E-01 3.3537E-01 Attachment No. 76 2.8729E-01 2.8756E-01 2.8783E-01 2.8808E-01 2.8834E-01
2. 8859E-01 2.8884E-01 2.8908E-01 2.9897E-01
3. 1975E-01 3.4325E-01 8.5400E-02 8.5903E-02 8.6385E-02 8.6845E-02 8.7287E-02 8.7711E-02
8. 8118E-02 8.8509E-02 9.8507E-02 1.0564E-01
1. 1071E-01 2.7448E+00 2.7452E+00
2. 7456E+00
2. 7459E+00 2.7462E+00
2. 7466E+00 2.7469E+00 2.7472E+00 2.7595E+00
2. 7677E+00 2.7708E+00 Page 76 - 20
1. 8396E-01
1. 8400E-01 1.8404E-01
1. 8407E-01 1.8410E-01 1.8413E-01 1.8416E-01
1. 8419E-01 1.8501E-01 1.8538E-01
1. 8550E-01 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 Time (hr) 0.001 0.050 0.300 0.500 0.800 0.967 1.267 1.567 1.800 2.000 2.300 2.600 2.900 3.100 3.400 3.700 4.000 4.300 4.600 4.900 5.200 5.500 5.800 6.100 6.400 6.700 7.000 7.300 7.600 7.900 8.000 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 BNP CR - Unprotected Thyroid TEDE (rem)

(rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 1.5779E-03 1.9562E-04 4.2556E-03 5.3168E-04 1.1812E-02 2.OOOOE-03 1.8487E-02 3.5129E-03 3.4707E-02 7.3600E-03 5.5804E-02 1.2477E-02 7.5243E-02 1.7219E-02 1.3514E+00 3.2896E-01 3.2146E+00 7.9694E-01 3.2225E+00 7.9922E-01 3.2285E+00 8.0127E-01 3.2318E+00 8.0253E-01 3.2357E+00 8.0429E-01 3.2389E+00 8.0590E-01 3.2414E+00 8.0738E-01 3.2434E+00 8.0876E-01 3.2451E+00 8.1005E-01 3.2465E+00 8.1124E-01 3.2477E+00 8.1237E-01 3.2488E+00 8.1343E-01 3.2498E+00 8.1443E-01 3.2507E+00 8.1537E-01 3.2516E+00 8.1627E-01 3.2524E+00 8.1712E-01 3.2531E+00 8.1792E-01 3.2539E+00 8.1869E-01 3.2546E+00 8.1942E-01 3.2553E+00 8.2011E-01 3.2555E+00 8.2034E-01 3.2559E+00 8.2074E-01 3.2563E+00 8.2112E-01 3.2567E+00 8.2148E-01 3.2570E+00 8.2183E-01 3.2574E+00 8.2217E-01 3.2578E+00 8.2249E-01 3.2581E+00 8.2280E-01 3.2585E+00 8.2310E-01 3.2728E+00 8.3078E-01 3.2883E+00 8.3443E-01 3.2973E+00 8.3581E-01

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 76 Page 76-21 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB dose location.

Please disregard the two-hour worst doses for the other dose locations

                                                                                                                            1. 0######

Whole Body (rem) 1.2943E-01 Whole Body (rem) 4.8311E-02 Whole Body (rem) 3.3630E-02 Unprotected Whole Body (rem) 6.2455E-01 Thyroid (rem) 6.4706E-01 Thyroid (rem) 2.4515E-01 Thyroid (rem) 2.6435E+00 Dose Thyroid (rem) 3.2147E+00 TEDE (rem)

1. 6442E-01 TEDE (rem)
6. 1527E-02 TEDE (rem) 1.7700E-01 TEDE (rem) 7.9859E-01 BNP EAB Time (hr) 1.3 BNP LPZ Time (hr) 0.9 BNP CR Time (hr) 1.8 BNP CR Time (hr) 0.8

CAROLINA POWER & LIG HT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

81-1 1

1 Attachment No. 81 RADTRAD Case 2 with 10,000 cfm TSC Inleakage, No Sprays, Revised Primary Leak

Page 81-2 Calculation No. BNP-RAD-007 Revision 1 RADTRAD Version 3.02 run on 4/02/2002 at 9:35:46

                                                1. %############################################4##

File information Plant file name

= C:\\RADTRAD V3.02\\Accept\\pppst5_iptS_10000cfm-nospray_lvol newleak-p-tscl 2 0.psf Inventory file name

= c:\\radtrad v3.02\\defaults\\bnploca.nif Scenario file name

= C:\\RADTRAD V3.02\\Accept\\pppst5ipt810000cfmflnospray-lvol-newleak-p-tscl20.psf Release file name

= c:\\radtrad v3.02\\defaults\\bnploca.rft Dose conversion file name = c:\\radtrad v3.02\\defaults\\fgrll&12-inp ff## f#

ftfttt#

  1. t ft ftf#tf ft#ft#

A ft ft ft# ft ft ft

  1. t ##f ft #t#

ft ft ft ft ft ft ft ft ft #ffft

  1. t f ft ft##
  1. t ft fft#

ftf ft

  1. tf #

ft ft ft#f##

ft ft ft ft ft ft ft ft

  1. t
  1. t ft ft
  1. t
  1. t Radtrad 3.02 1/5/2000 BNP - Primary Leakage via SGTS & Stac]

Nuclide Inventory File:

c:\\radtrad v3.02\\defaults\\bnploca.nif Plant Power Level:

2.9810E+03 Compartments:

3 Compartment 1:

BNP Drywell 3

1.6400E+05 0

0 0

1 0

Compartment 2:

Environment 2

0.OOOOE+00 0

0 0

0 0

Compartment 3:

k after PPP -

No Sprays -

1 Volume ft ft

        1. tftf
  1. t ft ftftt##f ft ft ft Attachment No. 81

Calculation No. BNP-RAD-007 Revision 1 BNP TSC 1

2.0880E+05 0

0 0

0 0

Pathways:

4 Pathway 1:

BNP Drywell 1

2 2

Pathway 2:

Environment 2

3 2

Pathway 3:

Environment 2

3 2

Attachment No. 81 to Environment to BNP TSC - Normal/Emergency Outside Air Intake to BNP TSC - Normal/Emergency Outside Air Inleakage Pathway 4:

BNP TSC to Environment TSC Exhaust 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1

1.0000E+00 c:\\radtrad v3.02\\defaults\\fgrll&12.inp c:\\radtrad v3.02\\defaults\\bnploca.rft 0.000OE+00 1

9.5000E-01 4.8500E-02 1.5000E-03 Overlying Pool:

0 0.OOOOE+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

1.O000E+00 Page 81-3

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 0

0 0

3 3

1. 0000E+01 0

Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

0 1

0 0

0 0

0 0

0 Pathways:

4 Pathway 1:

0 0

0 0

0 1

4 o.OOOOE+00 5.OOOOE-02 2.4000E+01 7.2000E+02 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

3 0.0000E+00 2.000OE+00 0.OOOOE+00 5.1920E-01 4.1540E-01 0.0000E+00 4.6900E+03 4.6900E+03 0.OOOOE+00 9.9000E+01

9. 9000E+01 0.OOOOE+00 0.OOOOE+00 9.5000E+01 0.OOOOE+00
9. 9000E+01 9.9000E+01 0.OOOOE+00 0.OOOOE+00
9. OOOOE+01 0.OOOOE+00 9.9000E+01 9.9000E+01 0.OOOOE+00 0.OOOOE+00 9.OOOOE+01 Page 81-4

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 7.2000E+02 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 o.- 000E+00

7. 2000E+02 0

0 0

0 0

0 Pathway 4:

0 0

0 0

0 1

3 o.OOOOE+00

2. OOOOE+00 7.-2000E+02 0

0 0

0 0

0 Dose 0.000 OE+00

1. 0000E+04
0. 000013+00
0. 0000E+00
0. 0000E+00
0. 0000E+00
0. 0000E+00
0. OOOOE÷00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+O0 A
1. 4690E+04
1. 4690E+04
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00
0. OOOOE+00 0.0OOO13+00
0. OOOOE+00 Locations:

4 Location 1:

BNP FAB 2

1 4

0. 0000E400 1.-800013+00
2. 3000E+00 7-.2000 E+02 1

4

0. OOOOE+00
8. OOOOE+00 2.4000E+01 7.2000E+02
3. 6300E-06
5. 8500E-05 3.6300E 06
0. OOOOE÷00 3.5000E-04
1. 8000E-04 2.3000E-04
0. OOOOE+00 Page 81-5

Calculation No. BNP-RAD-007 Revision I 0

Location 2:

BNP LPZ 2

1 7

o.OOOOE+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01 9.6000E+01 7.2000E+02 1

4 o.0000E+00 8.OOOOE+00 2.4000E+01 7.2000E+02 0

Location 3:

BNP TSC 3

0 1

2 o.0000E+00 7.2000E+02 Attachment No. 81 3.5000E-06 1.8800E-05 1.9200E-06 1.4200E-06 7.4000E-07 3.0700E-07 o.0000E+00 3.5000E-04 1.8000E-04 2.3000E-04 o.OOOOE+00 A

3.5000E-04 0.OOOOE+00 1

4 0.OOOOE+00 1.0000E+00 2.4000E+01 6.OOOOE-01 9.6000E+01 4.OOOOE-01 7.2000E+02 O.OOOOE+00 Location 4:

BNP TSC - Unprotected Dose 2

1 7

o.OOOOE+00 1.8000E+00 2.3000E+00 8.0000E+00 2.4000E+01

9. 6000E+01 7.2000E+02 1

2 o.0000E+00 7.2000E+02 3.7400E-06

2. 1600E-04 1.2500E-06 7.2300E-07 2.2100E-07
4. 0100E-08 0.0000E+00 3.5000E-04 0.OOOOE+00 0

Effective Volume Location:

1 7

0.OOOOE+00 3.7400E-06 1.8000E+00 2.1600E-04 2.3000E+00 1.2500E-06 Page 81-6

Calculation No. BNP-RAD-007 Revision I 8.OOOOE+00 2.4000E+01

9. 6000E+01 7.2000E+02 Attachment No. 81 7.2300E-07 2.2100E-07
4. OlOOE-08 0.OOOOE+00 Simulation Parameters:

1 0.OOOOE+00 0.0000E+00 Output Filename:

C:\\RADTRAD V3.o18 1

1 1

1 0

End of Scenario File Page 81-7

Calculation No. BNP-RAD-007 Revision 1 A

Attachment No. 81 Page 81-8

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 Page 81-9 RADTRAD Version 3.02 run on 4/02/2002 at 9:35:46 Plant Description Number of Nuclides =

60 Inventory Power 1.0000E+00 MWth Plant Power Level =

2.9810E+03 MWth Number of compartments

=

3 Compartment information Compartment number 1

(Source term fraction =

1.OOOOE+00 Name: BNP Drywell Compartment volume =

1.6400E+05 (Cubic feet)

Removal devices within compartment:

Deposition Pathways into and, out of compartment 1

Pathway to compartment number 2: BNP Drywell to Environment Compartment number 2

Name: Environment Pathways into and out of compartment 2

Pathway to compartment number 3: Environment to BNP TSC - Normal/Emergenc Pathway to compartment number 3: Environment to BNP TSC - Normal/Emergenc Pathway from compartment number 1: BNP Drywell to Environment Pathway from compartment number 3: BNP TSC to Environment -

TSC Exhaust Compartment number 3

Name:

BNP TSC Compartment volume =

2.0880E+05 (Cubic feet)

Pathways into and out of compartment 3

Pathway to compartment number 2: BNP TSC to Environment -

TSC Exhaust Pathway from compartment number 2: Environment to BNP TSC - Normal/Emergenc Pathway from compartment number 2: Environment to BNP TSC - Normal/Emergenc Total number of pathways =

4

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 Page 81-10 RADTRAD Version 3.02 run on 4/02/2002 at 9:35:46 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled RELEASENAME = BWR, NUREG/CR-6604, Table 3.1 Release Fractions and Timings NOBLES IODINE CESIUM TELLURIUM STRONTIUM BARIUM RUTHENIUM CERIUM LANTHANUM GAP 0.5000 hrs 5.OOOOE-02 5.OOOOE-02 5.OOOOE-02 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 EARLY IN-VESSEL 1.5000 hrs 9.5000E-01

2. 5000E-01 2.OOOOE-01
5. OOOOE-02
2. OOOOE-02
2. OOOOE-02
2. 5000E-03 5.OOOOE-04 2.OOOOE-04 A

Iodine fractions Aerosol Elemental Organic 9.5000E-01 4.8500E-02 1.5000E-03 COMPARTMENT DATA Compartment number 1: BNP Drywell Natural Deposition (Powers' model):

Aerosol data Reactor type:

3 Percentile =

10 (%)

Compartment number 2: Environment Compartment number 3: BNP TSC PATHWAY DATA Pathway number 1: BNP Drywell to Environment Pathway Filter:

Removal Data Time (hr) 0.OOOOE+00 5.OOOOE-02 2. 4000E+01 7.2000E+02 Flow Rate (cfm) 0.OOOOE+00 5.1920E-01 4.1540E-01 0.OOOOE+00 Filter Efficiencies (%)

Aerosol Elemental Organic 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 9.9000E+01 9.9000E+01 9.9000E+01 9.9000E+01 9.9000E+01 9.9000E+01 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 2: Environment to BNP TSC - Normal/Emergenc Pathway Filter:

Removal Data

Calculation No. BNP-RAD-007 Revision I Attachment No. 81 Page 81-11 Time (hr) 0.OOOOE+00 2.OOOOE+00 7.2000E+02 Flow Rate (cfm) 4.6900E+03 4.6900E+03 0.OOOOE+00 Filter Efficiencies

(%)

Aerosol Elemental Organic 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 9.5000E+01 9.OOOOE+01 9.OOOOE+01 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 3: Environment to BNP TSC -

Normal/Emergenc Pathway Filter:

Removal Data Time (hr) o.OOOOE+00 7.2000E+02 Flow Rate (cfm) 1.OOOOE+04 0OOOOE+00 Filter Efficiencies

(%)

Aerosol Elemental Organic 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 4: BNP TSC to Environment -

TSC Exhaust Pathway Filter:

Removal Data Time (hr) o.OOOOE+00 2.OOOOE+00 7.2000E+02 A Flow Rate (cfm) 1.4690E+04 1.4690E+04 0.OOOOE+00 Filter Efficiencies (%)

Aerosol Elemental Organic 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 LOCATION DATA Location BNP EAB Location X/Q Data Time (hr) o.0000E+00 1.8000E+00 2.3000E+00 7.2000E+02 is in compartment X/Q (s

  • m^-3) 3.6300E-06 5.8500E-05 3.6300E-06 0.0000E+00 Location Breathing Rate Data Time (hr)

Breathing Rate (m-3

  • sec^-l) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 Location BNP LPZ is in compartment 2

Location X/Q Data Time (hr)

0. 0000E+00
1. 8000E+00
2. 3000E+00
8. 0000E+00 2.4000E+01
9. 6000E+01 7.2000E+02 X/Q (s
  • m^-3) 3.5000E-06 1.8800E-05 1.9200E-06 1.4200E-06 7.4000E-07 3.0700E-07 0.OOOOE+00 Location Breathing Rate Data Time (hr)

Breathing Rate (mW3

  • sec^-l) 0.0000E+00 3.5000E-04 2

Calculation No. BNP-RAD-007 Revision I Attachment No. 81 Page 81-12 8.OOOOE+00 2.4000E+01 7.2000E+02 Location BNP TSC Location X/Q Data Time (hr) 0.OOOOE+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01 9.6000E+01 7.2000E+02 Location Breathing Time (hr) o.0000E+00 7.2000E+02.

1.8000E-04 2.3000E-04 0.OOOOE+00 is in compartment 3

X/Q (s

  • m^-3) 3.7400E-06
2. 1600E-04 1.2500E-06 7.2300E-07
2. 2100E-07 4.0100E-08 0.OOOOE+00 Rate Data Breathing Rate (m^3
  • sec^-1) 3.5000E-04 0.OOOOE+00 Location Occupancy Time (hr) 0.OOOOE+00 2.4000E+01
9. 6000E+010 7.2000E+02 Location BNP TSC Location X/Q Data Time (hr) 0.OOOOE+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01 9.6000E+01 7.2000E+02 Factor Data Occupancy Factor 1.0000E+00 6.0000E-01 4.0000E-01 0.OOOOE+00 Unprotected Dose X/Q (s
  • m^-3) 3.740OE-06 2.1600E-04 1.2500E-06 7.2300E-07 2.2100E-07 4.0100E-08 0.0000E+00 is in compartment 2

Location Breathing Rate Data Time (hr)

Breathing Rate (m^3 0.0000E+00 3.5000E-04 7.2000E+02 0.OOOOE+00 USER SPECIFIED TIME Time 0.OOOOE+00 STEP DATA -

SUPPLEMENTAL TIME STEPS Time step 0.OOOOE+00 sec^-1)

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 Page 81-13 RADTRAD Version 3.02 run on 4/02/2002 at 9:35:46 Dose Output BNP EAB Doses:

Time (h)

=

0.0ý00 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.OOOOE+00 0.0000E+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP LPZ Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.OOOOE+00 0.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP TSC Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.00003E+00 Thyroid O.OOOOE+00 O.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP TSC - Unprotected Dose Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.OOOOE+00 0.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.7710E-04 2.7710E-04 Thyroid 3.3207E-03 3.3207E-03 TEDE

4. 1486E-04
4. 1486E-04 BNP LPZ Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.6718E-04 2.6718E-04 Thyroid 3.2018E-03 3.2018E-03 TEDE 4.OOO1E-04

4. 0001E-04

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 Page 81-14 BNP TSC Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.7818E-06 6.7818E-06 Thyroid 1.5625E-03 1.5625E-03 TEDE

7. 1623E-05
7. 1623E-05 BNP TSC - Unprotected Dose Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.8550E-04 2.8550E-04 Thyroid 3.4213E-03 3.4213E-03 TEDE 4.2743E-04 4.2743E-04 BNP FAB Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.0142E-02 1.0419E-02 Thyroid 5.5458E-02 5.8779E-02 TEDE 1.3036E-02 1.3450E-02 BNP LPZ Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 9.7786E-03 1.0046E-02 Thyroid 5.3472E-02 5.6674E-02 TEDE 1.2569E-02 1.2969E-02 BNP TSC Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.0200E-04 4.0878E-04 Thyroid 4.4176E-02 4.5738E-02 TEDE 2.6690E-03 2.7407E-03 BNP TSC -

Unprotected Dose Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

BNP EAB Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.0449E-02 1.0735E-02 Whole Body 4.4510E-02 5.4929E-02 Thyroid 5.7138E-02 6.0560E-02 Thyroid 2.3478E-01 2.9355E-01 TEDE 1.3431E-02 1.3858E-02 TEDE 5.7219E-02 7.0670E-02 BNP LPZ Doses:

Time (h)

=

Delta dose (r Accumulated d 2.0000 Whole Body em) 1.4304E-02 Lose (rem) 2.4350E-02 Thyroid 7.5449E-02 1.3212E-01 TEDE 1.8388E-02 3.1357E-02 BNP TSC Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.7999E-03 3.2086E-03 Thyroid 2.7865E-01 3.2439E-01 TEDE 1.7875E-02

2. 0615E-02 BNP TSC -

Unprotected Dose Doses:

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 Page 81-15 Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.6434E-01 1.7508E-01 Thyroid

8. 6686E-01 9.2742E-01 TEDE 2.1127E-01 2.2513E-01 BNP EAB Doses:

Time (h)

=

Delta dose (0 Accumulated c 2.3000 Whole Body 7em) 6.7314E-02 lose (rem) 1.2224E-01 Thyroid 3.4165E-01 6.3520E-01 TEDE 8.5832E-02

1. 5650E-01 BNP LPZ Doses:

Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.1632E-02 4.5982E-02 Thyroid 1.0979E-01 2.4192E-01 TEDE 2.7584E-02

5. 8941E-02 BNP TSC Doses:

Time (h)

=

Delta dose (r Accumulated c 2.3000 Whole Body

-em) 9.7695E-03 lose (rem) 1.2978E-02 Thyroid 8.1521E-01 1.1396E+00 TEDE 5.3959E-02 7.4575E-02 BNP TSC - Unprotected Dose Doses:

Time (h)

=

2.3 Delta dose (rem)

Accumulated dose BNP EAB Doses:

V00 Whole Body 2.4854E-01 (rem) 4.2362E-01 Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.4852E-02 1.6709E-01 Thyroid 1.2615E+00

2. 1889E+00 Thyroid 8.5739E-02 7.2094E-01 TEDE
3. 1692E-01 5.4205E-01 TEDE 4.9077E-02
2. 0558E-01 BNP LPZ Doses:

Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

BNP TSC Doses:

Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.3723E-02 6.9706E-02 Whole Body 9.2497E-03 2.2228E-02 Thyroid 4.5349E-02 2.8727E-01 Thyroid

6. 8155E-01
1. 8212E+00 TEDE 2.5958E-02 8.4899E-02 TEDE
4. 6125E-02 1.2070E-01 BNP TSC - Unprotected Dose Doses:

Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.5445E-02 4.3907E-01 Thyroid 2.9524E-02

2. 2184E+00 TEDE 1.6900E-02
5. 5895E-01 BNP EAB Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.3886E-02 2.0098E-01 Thyroid 3.0555E-02

7. 5149E-01 TEDE 3.4850E-02 2.4043E-01

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 Page 81-16 BNP LPZ Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3256E-02 8.2962E-02 Thyroid 1.1952E-02 2.9922E-01 TEDE 1.3633E-02 9.8532E-02 BNP TSC Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.6934E-04 2.2597E-02 Thyroid 8.5735E-03 1.8297E+00 TEDE 6.4088E-04 1.2134E-01 BNP TSC - Unprotected Dose Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.7493E-03 4.4582E-01 Thyroid 1.1833E-02 2.2302E+00 TEDE 7.1226E-03 5.6607E-01 BNP EAB Doses:

Time (h)

= 96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.1862E-02 2.3284E-01 Thyroid

1. 0194E-01
8. 5343E-01 TEDE 3.4981E-02 2.7541E-01 BNP LPZ Doses:

Time (h)

=

96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.4953E-03 8.9457E-02 Thyroid

2. 0781E-02 3.2000E-01 TEDE 7.1310E-03 1.0566E-01 BNP TSC Doses:

Time (h)

=

96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.4967E-05 2.2662E-02 BNP TSC - Unprotected Dose Doses:

Time (h)

=

96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.9398E-03 4.4776E-01 Thyroid

4. 1494E-03 1.8339E+00 Thyroid 9.4443E-03 2.2397E+00 TEDE 1.9193E-04 1.2153E-01 TEDE 2.2287E-03
5. 6830E-01 BNP EAB Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 5.1558E-02 2.8440E-01 Thyroid 2.7781E-01 1.1312E+00 TEDE 6.0018E-02 3.3543E-01 BNP LPZ Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.3604E-03 9.3817E-02 Thyroid 2.3496E-02 3.4349E-01 TEDE 5.0759E-03 1.1074E-01 BNP TSC Doses:

Calculation No. BNP-RAD-007 Revision 1 Time (h)

= 720.0000 Whole Body Delta dose (rem) 1.2360E-05 Accumulated dose (rem) 2.2674E-02 BNP TSC Unprotected Dose Doses:

Time (h)

= 720.0000 Whole Body Delta dose (rem) 5.6955E-04 Accumulated dose (rem) 4.4833E-01 Attachment No. 81 Thyroid 1.3444E-03 1.8352E+00 Thyroid 4.6702E-03 2.2444E+00 Page 81-17 TEDE 5.3300E-05 1.2159E-01 TEDE

7. 1177E-04
5. 6901E-01 838 1-131 Summary BNP Drywell 1-131 (Curies) 4.4384E+03 3.9938E+05 2.5243E+06 3.3565E+06 7.2189E+06 1.1022E+07 1.4399E+07 1.7463E+07 1.8425E+07 2.0269E+07 1.6649E+07
1. 2851E+07
9. 9858E+06
7. 8236E+06
6. 1920E+06
4. 9607E+06
4. 0315E+06
3. 3301E+06 2.8006E+06 2.4009E+06 2.1655E+06 2.0032E+06 1.8671E+06 1.7529E+06 1.6570E+06 1.5766E+06 1.5089E+06 1.4521E+06 1.4043E+06 1.3640E+06 1.3301E+06 1.3035E+06 1.2821E+06 1.2636E+06 1.2475E+06 1.2334E+06 1.2211E+06 1.2104E+06 1.0953E+06 Environment 1-131 (Curies) 0.OOOOE+00 0.OOOOE+00 8.5955E-01 1.7083E+00 4.6996E+00 9.9179E+00 1.7176E+01 2.6265E+01 2.9673E+01 3.7029E+01 4.7760E+01 5.6119E+01 6.2588E+01 6.7633E+01 7.1605E+01 7.4765E+01 7.7315E+01 7.9402E+01 8.1142E+01 8.2618E+01 8.3910E+01 8.5096E+01 8.6197E+01 8.7227E+01 8.8198E+01 8.9119E+01 8.9997E+01 9.0840E+01 9.1653E+01 9.2442E+01 9.3209E+01 9.3959E+01 9.4695E+01
9. 5420E+01
9. 6136E+01
9. 6842E+01 9.7541E+01 9.8234E+01 1.2748E+02 BNP TSC 1-131 (Curies) 0.OOOOE+00 0.OOOOE+00 1.4432E-05 2.4204E-05 5.4146E-05 9.5223E-05 1.3640E-04 1.7466E-04 1.8670E-04 7.5671E-03 8.3473E-03 2.3781E-03 6.9119E-04 2.1150E-04 7.2869E-05 3.1143E-05 1.7363E-05
1. 1948E-05 9.2655E-06
7. 6357E-06
6. 5779E-06
5. 9325E-06
5. 4658E-06
5. 0952E-06 4.7902E-06 4.5358E-06 4.3226E-06 4.1437E-06 3.9932E-06 3.8667E-06 2.6338E-06 2.2531E-06 2.1200E-06 2.0603E-06 2.0242E-06 1.9972E-06 1.9750E-06 1.9560E-06 1.7608E-06 Time (hr) 0.001 0.050 0.350 0.500 0.800 1.100 1.400 1.700 1.800 2.000 2.300 2.600 2.900 3.200 3.500 3.800 4.100 4.400 4.700 5.000 5.300 5.600 5.900 6.200 6.500 6.800 7.100 7.400 7.700 8.000 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000

Calculation No. BNP-RAD-007 Revision 1 96.000 8.3642E+05 720.000 8.0864E+04 Attachment No. 81 2.3233E+02 5.3846E+02 Page 81-18 3.2882E-07 5.7683E-09 Cumulative Dose Summary Time (hr) 0.001 0.050 0.350 0.500 0.800 1.100 1.400 1.700 1.800 2.000 2.300 2.600 2.900 3.200 3.500 3.800 4.100 4.400 4.700 5.000 5.300 5.600 5.900 6.200 6.500 6.800 7.100 7.400 7.700 8.000 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 Time (hr) 0.001 0.050 BNP LPZ BNP EAB Thyroid (rem)

O.O000E+00 0.0(

0.OOOOE+00 0.0(

1.6731E-03 2.0' 3.3207E-03 4.1' 9.2079E-03 1.51 1.9563E-02 3.9' 3.3981E-02 7.41 5.2021E-02 1.1i 5.8779E-02 1.3' 2.9355E-01 7.0' 6.3520E-01 1.5' 6.5164E-01 1.6:

6.6431E-01 1.6' 6.7415E-01 1.6!

6.8185E-01 1.7:

6.8795E-01 1.7 6.9284E-01 1.7!

6.9682E-01 1.8:

7.0012E-01 1.8 7.0290E-01 1.8 7.0532E-01 1.8!

7.0753E-01 1.9:

7.0957E-01 1.9:

7.1147E-01 1.9:

7.1325E-01 1.9 7.1493E-01 1.9:

7.1653E-01 2.0.

7.1805E-01 2.0:

7.1952E-01 2.0 7.2094E-01 2.0:

7.2164E-01 2.0 7.2233E-01 2.0.

7.2301E-01 2.0 7.2367E-01 2.1 7.2432E-01 2.1 7.2496E-01 2.1 7.2559E-01 2.1 7.2621E-01 2.1 7.5149E-01 2.4 8.5343E-01 2.7 1.1312E+00 3.3 TEDE (rem) 000E+00 0OOE+00 777E-04 486E-04 608E-03 473E-03 098E-03 802E-02 450E-02 670E-02 650E-01 128E-01 558E-01 949E-01 306E-01 635E-01 939E-01 221E-01 484E-01 731E-01 962E-01 180E-01 386E-01 580E-01 765E-01 940E-01 106E-01 264E-01 414E-01 558E-01 692E-01 821E-01 944E-01 062E-01 175E-01 283E-01 387E-01 487E-01 043E-01 541E-01 543E-01 Thyroid (rem) 0.OOOOE+00 0.OOOOE+00 1.6132E-03 3.2018E-03

8. 8781E-03 1.8862E-02 3.2764E-02
5. 0158E-02
5. 6674E-02
1. 3212E-01
2. 4192E-01 2.5061E-01 2.5732E-01
2. 6252E-01 2.6659E-01
2. 6982E-01 2.7240E-01
2. 7451E-01 2.7625E-01
2. 7773E-01 2.7900E-01
2. 8017E-01
2. 8125E-01 2.8226E-01 2.8320E-01
2. 8409E-01
2. 8493E-01 2.8574E-01 2.8652E-01
2. 8727E-01 2.8754E-01 2.8781E-01 2.8807E-01 2.8833E-01
2. 8859E-01 2.8884E-01 2.8909E-01 2.8933E-01 2.9922E-01 3.2000E-01 3.4349E-01 TEDE (rem) 0 OOOOE+00 0 OOOOE+00 2.0033E-04
4. 0001E-04
1. 5049E-03 3.8059E-03
7. 1444E-03
1. 1379E-02 1.2969E-02
3. 1357E-02
5. 8941E-02
6. 1466E-02 6.3742E-02 6.5809E-02 6.7699E-02 6.9438E-02
7. 1046E-02 7.2539E-02 7.3931E-02 7.5234E-02 7.6456E-02 7.7609E-02 7.8698E-02 7.9728E-02 8.0704E-02 8.1629E-02 8.2508E-02 8.3344E-02 8.4140E-02 8.4899E-02 8.5425E-02 8.5928E-02
8. 6410E-02 8.6870E-02 8.7312E-02 8.7736E-02 8.8143E-02 8.8534E-02 9.8532E-02 1.0566E-01
1. 1074E-01 BNP TSC -

Unprotected Thyroid (rem) 0.OOOOE+00 0.OOOOE+00 TEDE (rem) 0.OOOOE+00 O.OOOOE+00 BNP TSC Thyroid TEDE (rem)

(rem)

O.O000E+00 0.O000E+00 0.0000E+00 0.OOOOE+00 6.1890E-04 2.8376E-05 1.5625E-03 7.1623E-05 5.2724E-03 2.5968E-04 1.2658E-02 6.8615E-04 2.4215E-02 1.3909E-03 3.9739E-02 2.3618E-03 4.5738E-02 2.7407E-03 3.2439E-01 2.0615E-02 1.1396E+00 7.4575E-02 1.6170E+00 1.0673E-01 1.7534E+00 1.1584E-01 1.7936E+00 1.1851E-01 1.8063E+00 1.1938E-01 1.8110E+00 1.1971E-01 1.8133E+00 1.1989E-01 1.8147E+00 1.2001E-01 1.8157E+00 1.2011E-01 1.8165E+00 1.2019E-01 1.8171E+00 1.2026E-01 1.8177E+00 1.2032E-01 1.8183E+00 1.2038E-01 1.8188E+00 1.2043E-01 1.8192E+00 1.2049E-01 1.8196E+00 1.2053E-01 1.8200E+00 1.2058E-01 1.8204E+00 1.2062E-01 1.8208E+00 1.2066E-01 1.8212E+00 1.2070E-01 1.8214E+00 1.2073E-01 1.8217E+00 1.2075E-01 1.8219E+00 1.2077E-01 1.8220E+00 1.2079E-01 1.8222E+00 1.2081E-01 1.8224E+00 1.2083E-01 1.8226E+00 1.2084E-01 1.8227E+00 1.2086E-01 1.8297E+00 1.2134E-01 1.8339E+00 1.2153E-01 1.8352E+00 1.2159E-01

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 81 Page 81-19 0.350 0.500 0.800

1. 100 1.400 1.700 1.800 2.000 2.300 2.600 2.900 3.200 3.500 3.800 4.100 4.400 4.700 5.000 5.300 5.600 5.900 6.200 6.500 6.800 7.100 7.400 7.700 8.000 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 1.7238E-03 3.4213E-03 9.4869E-03
2. 0155E-02
3. 5010E-02 5.3598E-02 6.0560E-02 9.2742E-01
2. 1889E+00
2. 1945E+00 2.1989E+00 2.2023E+00 2.2049E+00 2.2070E+00 2.2087E+00 2.2101E+00 2.2112E+00 2.2122E+00 2.2130E+00 2.2138E+00 2.2145E+00 2.2151E+00 2.2158E+00 2.2163E+00 2.2169E+00 2.2174E+00 2.2179E+00 2.2184E+00 2.2187E+00 2.2189E+00 2.2192E+00 2.2195E+00 2.2197E+00 2.2200E+00 2.2202E+00 2.2204E+00 2.2302E+00 2.2397E+00 2.2444E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB dose location.

Please disregard the two-hour worst doses for the other dose locations BNP EAB Time Whole Body (hr)

(rem) 1.4 1.2956E-01 BNP LPZ Time Whole Body (hr)

(rem) 0.8 4.8213E-02 Thyroid (rem) 6.4530E-01 Thyroid (rem) 2.4620E-01 TEDE (rem) 1.6446E-01 TEDE (rem)

6. 1478E-02 2.1407E-04 4.2743E-04
1. 6081E-03 4.0669E-03 7.6343E-03 1.2159E-02 1.3858E-02 2.2513E-01 5.4205E-01 5.4369E-01 5.4517E-01
5. 4652E-01
5. 4775E-01 5.4888E-01
5. 4993E-01
5. 5090E-01
5. 5181E-01 5.5265E-01
5. 5345E-01
5. 5420E-01
5. 5491E-01 5.5558E-01 5.5622E-01 5.5682E-01 5.5739E-01 5.5793E-01 5.5845E-01 5.5895E-01 5.5922E-01 5.5948E-01
5. 5973E-01 5.5997E-01 5.6020E-01 5.6042E-01 5.6063E-01
5. 6083E-01
5. 6607E-01 5.6830E-01
5. 6901E-01

Calculation No. BNP-RAD-007 Revision I Attachment No. 81 Page 81-20 Whole Body (rem) 2.1361E-02

- Unprotected Whole Body (rem) 4.2461E-01 Thyroid (rem) 1.7778E+00 Dose Thyroid (rem)

2. 1880E+00 TEDE (rem)
1. 1770E-01 TEDE (rem) 5.4307E-01 A

BNP TSC Time (hr) 1.4 BNP TSC Time (hr) 0.8

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

91-1 1

A Attachment No. 91 BNP Post-LOCA Enviroment Activity Based on Case 2

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91

                                  1. iti#####t#####i#######################it#t####it
        1. i#i#
    1. it RADTRAD Version 3.02 run on 4/04/2002 at 8:26:16 File information
                                                                              1. itit
                                1. ###i##############

Plant file name C:\\RADTRAD V3.02\\Accept\\PPPST5NoSpray_p_EnvrAct.psf Inventory file name

= c:\\radtrad v3.02\\defaults\\bnploca.nif Scenario file name

= C:\\RADTRAD V3.02\\Accept\\PPPST5_NoSprayPEnvrAct.psf Release file name

= c:\\radtrad v3.02\\defaults\\bnploca.rft Dose conversion file name = c:\\radtrad v3.02\\defaults\\fgrll&12.inp Pla t

itwe itit it itt itit it i

Nucid InventryFie 3

1. 6400E+05 0

0 0

1 0

Compartment 2:

Environment 2

0. 00005+00 0

0 0

0 0

Compartment 3:

Page 91-2

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-3 BNP Control Room 1

2.9870E+05 0

0 1

0 0

Pathways:

4 Pathway 1:

BNP Drywell 1

2 2

Pathway 2:

Environment 2

3 2

Pathway 3:

Environment 2

3 2

Pathway 4:

BNP Control 3

to Environment to BNP Control Room - Normal/Emergency Outside Air Intake to BNP Control Room - Normal/Emergency Outside Air Inleakage A

Room to Environment -

CR Exhaust 2

2 End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1

1.OOOOE+00 c:\\radtrad v3-02\\defaults\\fgrll&12.inp c:\\radtrad v3.02\\defaults\\bnploca.rft o.0000E+00 1

9.5000E-01 4.8500E-02 1.5000E-03 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

1.OOOOE+00

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 0

0 0

3 3

1. OOOOE+01 0

Compartment 2:

1 1

0 0

0 0

0 0

0 Compartment 3:

0 1

0 0

0 0

1 4.OOOOE+02 3

0.OOOOE+00 3.OOOOE-01 7.2000E+02 0

0 Pathways:

4 Pathway 1:

0 0

0 0

0 1

4 0.OOOOE+00 5.00003E-02 2.4000E+01 7.2000E+02 0

0 0

0 0

0 Pathway 2:

0 0

0 0

A 0.OOOOE+00

9. 5000E+01 0.OOOOE+00 0.OOOOE+00
5. 1920E-01 4.1540E-01 0.OOOOE+00 0.OOOOE+00
9. OOOOE+01 0.OOOOE+00 0.00003E+00
9. 9000E+01 9.9000E+01 0.OOOOE+00 0.OOOOE+00 9.000 OE+01 0.OOOOE+00 0.OOOOE+00
9. 9000E+01
9. 9000E+01 0.OOOOE+00 0.OOOOE+00 9.9000E+01
9. 9000E+01 0.OOOOE+00 Page 91-4

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 0

1 2

o.OOOOE+00

7. 2000E+02 0

0 0

0 0

0 0

0 0

0 1

2 o.OOOOE+OO 7.2000E+/-02 0

0 0

0 0

0 Pathway 4:

0 0

0 0

0 1

2 o.OOOOE+OO 7.-2000E+02 0

0 0

0 0

0 Dose Locations:

4 Location 1:

BNP EAB 2

1 4

0. OOOOE+OO
1. 8000E+00 2.3000E+00 7.2000E+02 1

4

1. OOOOE-20
0. OOOOE+OO
1. OOOOE-20
0. OOOOE+O0 o.OOOOE+OO o

.OOOOE+OO

0. OOOOE+0O
0. OOOOE+0O
0. OOOOE+OO
0. OOOOE+O0 o.OOOOE+0O o.OOOOEO00 o.OOOOE+0O o.OOOOE+O0 o.OOOOE÷00 o.OOOOE+00 AA
1. OOOOE-20
0. OOOOE+0O
0. OOOOE+00 o.OOOOE÷00 o.OOOOE+00 o -OOOOE+00 o.OOOOE+O0 o.OOOOE+OO 3.6300E 06
5. 8500E-05 3-6300E-06
0. OOOOE+OO O.OOOOE+00 3-50OOE-04 Page 91-5

Calculation No. BNP-RAD-007 Revision 1 8.OOOOE+00 2.4000E+01 7.2000E+02 0

Location 2:

BNP LPZ 2

1 7

0.OOOOE+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01 9.6000E+01 7.2000E+02 1

4 0.OOOOE+00 8.OOOOE+00 2.4000E+01 7.2000E+02 0

Location 3:

BNP CR 3

0 1

2 0.OOOOE+00 7.2000E+02 1

Attachment No. 91 1.8000E-04 2.3000E-04 0.0000E+00 3.5000E-06 1.8800E-05 1.9200E-06 1.4200E-06 7.4000E-07 3.0700E-07 0.OOOOE+00 3.50OOE-04 1.8000E-04 2.3000E-04 0.OOOOE+00 A

3.5000E-04 0.OOOOE+00 4

0.OOOOE+00 1.OOOOE+00 2.4000E+01 6.OOOOE-01 9.6000E+01 4.OOOOE-01 7.2000E+02 0.OOOOE+00 Location 4:

BNP CR -

Unprotected Dose 2

1 7

0.OOOOE+00 1.8000E+00 2.3000E+00 8.OOOOE+00 2.4000E+01

9. 6000E+01 7.2000E+02 1

2 0.OOOOE+00 7.2000E+02 0

4.6500E-06 3.1900E-04 1.7300E-06 1.0600E-06 3.6200E-07 7.7600E-08 0.OOOOE+00 3.5000E-04 0.OOOOE+00 Effective Volume Location:

1 7

Page 91-6

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-7 0.0000E+00 4.6500E-06 1.8000E+00 3.1900E-04 2.3000E+00 1.7300E-06 8.0000E+00 1.0600E-06 2.4000E+01 3.6200E-07 9.6000E+01 7.7600E-08 7.2000E+02 0.0000E+00 Simulation Parameters:

8 0.0000E+00 5.OOOOE-01 1.0000E+00 1.0000E+00 2.0000E+00 2.0000E+00 4.0000E+00 4.0000E+00 8.0000E+00 1.6000E+01 2.4000E+01 2.4000E+01 1.2000E+02 1.2000E+02 7.2000E+02 0.OOOOE+00 Output Filename:

C:\\RADTRAD V3.o24 1

1 1

1 0

End of Scenario File A

Page 91-8 Calculation No. BNP-RAD-007 Revision 1 A.

Attachment No. 91

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 RADTRAD Version 3.02 run on 4/04/2002 at 8:26:16 Plant Description Number of Nuclides =

60 Inventory Power =

1.0000E+00 MWth Plant Power Level =

2.9810E+03 MWth Number of compartments

=

3 Compartment information Compartment number 1

(Source term fraction =

1.OOOOE+00 Name: BNP Drywell Compartment volume =

1.6400E+05 (Cubic feet)

Removal devices within compartment:

Deposition Pathways into and out of compartment 1

A Pathway to compartment number 2: BNP Drywell Compartment number 2

Name: Environment Pathways into and out of compartment 2

Pathway to compartment number 3: Environment Pathway to compartment number 3: Environment Pathway from compartment number 1: BNP Drywell Pathway from compartment number 3: BNP Control to Environment to BNP Control Room -

Normal to BNP Control Room -

Normal to Environment Room to Environment -

CR Exh Compartment number 3

Name: BNP Control Room Compartment volume =

2.9870E+05 (Cubic feet)

Removal devices within compartment:

Filter(s)

Pathways into and out of compartment 3

Pathway to compartment number 2: BNP Control Room to Environment -

CR Exh Pathway from compartment number 2: Environment to BNP Control Room -

Normal Pathway from compartment number 2: Environment to BNP Control Room -

Normal Total number of pathways =

4 Page 91-9

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-10 RADTRAD Version 3.02 run on 4/04/2002 at 8:26:16 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled RELEASENAME

= BWR, NUREG/CR-6604, Table 3.1 Release Fractions and Timings NOBLES IODINE CESIUM TELLURIUM STRONTIUM BARIUM RUTHENIUM CERIUM LANTHANUM GAP 0.5000 hrs 5.0000E-02 5.OOOOE-02

5. 0000E-02 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 0 OOOOE+00 EARLY IN-VESSEL 1.5000 hrs 9.5000E-01 2.5000E-01 2.OOOOE-01 5.OOOOE-02 2.OOOOE-02 2.OOOOE-02 2.5000E-03 5.OOOOE-04 2.OOOOE-04 Iodine fractions' Aerosol Elemental Organic COMPARTMENT DATA
9. 5000E-01 4.8500E-02 1.5000E-03 Compartment number 1: BNP Drywell Natural Deposition (Powers' model):

Aerosol data Reactor type:

3 Percentile

=

10 (%)

Compartment number 2: Environment Compartment number 3: BNP Control Room Compartment Filter Data Time (hr) 0.OOOOE+00

3. 0OOOE-01 7.2000E+02 Flow Rate (cfm) 4.OOOOE+02 4.OOOOE+02 4.OOOOE+02 Filter Aerosol 0.OOOOE+00
9. 5000E+01 0.OOOOE+00 Efficiencies Elemental 0.OOOOE+00 9.OOOOE+01 0.OOOOE+00

(%)

Organic 0.OOOOE+00

9. OOOOE+01 0.OOOOE+00 PATHWAY DATA Pathway number 1: BNP Drywell to Environment Pathway Filter:

Removal Data Time (hr)

Flow Rate (cfm)

Filter Efficiencies (%)

Aerosol Elemental Organic

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-11 o.OOOOE+00 5.OOOOE-02 2.4000E+01 7.2000E+02 o.OOOOE+00 5.1920E-01

4. 1540E-01 o.OOOOE+00 0.OOOOE+00 9.9000E+01 9.9000E+01 o.OOOOE+00 o.OOOOE+00 9.9000E+01 9.9000E+01 O.OOOOE+00 0.OOOOE+00
9. 9000E+01
9. 9000E+01 0.OOOOE+00 Pathway number 2: Environment to BNP Control Room -

Normal Pathway Filter:

Removal Data Time (hr) 0.0000E+00 7.2000E+02 Flow Rate (cfm) 1.OOOOE-20 0.OOOOE+00 Aeros 0.0000E 0.0000E Filter Efficiencies 0ol Elemental E+00 0.OOOOE+00

'+00 0.OOOOE+00

(%)

Organic 0.OOOOE+00 0.OOOOE+00 Pathway number 3: Environment to BNP Control Room -

Normal Pathway Filter:

Removal Data Time (hr) 0.0000E+00 7.2000E+02 Flow Rate (cfm) 1.OOOOE-20 0.OOOOE+00 Filter Efficiencies (%)

Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.OOOOE+00 0.0000E+00 0.0000E+00 0.OOOOE+00 Pathway number 4: BNP Control Room to Environment -

CR Exh Pathway Filter:

Removal Data Time (hr) o.OOOOE+00 7.2000E+02 Flow Rate (c fiM) 1.0000E-20 0.0000E+00 Filter Efficiencies (%)

Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location BNP EAB Location X/Q Data Time (hr) o.0000E+00 1.8000E+00 2.3000E+00 7.2000E+02 Location Breathing Time (hr) o.0000E+00 8.0000E+00 2.4000E+01 7.2000E+02 Location BNP LPZ Location X/Q Data Time (hr) o.0000E+00 1.8000E+00 2.3000E+00 8.0000E+00 2.4000E+01 is in compartment 2

X/Q (s

  • m^-3) 3.6300E-06 5.8500E-05 3.6300E-06 0.OOOOE+00 Rate Data Breathing Rate (mW3
  • sec^-l) 3.5000E-04 1.8000E-04 2.3000E-04 0.0000E+00 is in compartment 2

X/Q (s

  • m'-3) 3.5000E-06 1.8800E-05 1.9200E-06 1.4200E-06 7.4000E-07

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-12

9. 6000E+01 7.2000E+02 Location Breathing Time (hr) 0.0000E+00 8.OOOOE+00 2.4000E+01 7.2000E+02 Location BNP CR Location X/Q Data Time (hr) o.OOOOE+00 1.8000E+00 2.3000E+00 8.0000E+00 2.4000E+01 9.6000E+01 7.2000E+02 Location Breathing Time (hr) o.0000E+00 7.2000E+02 A

3.0700E-07 o.OOOOE+00 Rate Data Breathing Rate (mW3

  • sec^-1) 3.5000E-04 1.8000E-04 2.3000E-04 0.0000E+00 is in compartment 3

X/Q (s

  • m^-3) 4.6500E-06 3.1900E-04 1.7300E-06 1.0600E-06 3.6200E-07 7.7600E-08 0.OOOOE+00 Rate Data Breathing Rate (m^3
  • sec^-l) 3.5000E-04 o.0000E+00 Location Occupancy Time (hr) 0.0000E+00 2.4000E+01 9.6000E+01 7.2000E+02 Location BNP CR Location X/Q Data Time (hr) o.0000E+00 1.8000E+00 2.3000E+00 8.0000E+00 2.4000E+01 9.6000E+01 7.2000E+02 Factor Data Occupancy Factor 1.OOOOE+00 6.0000E-01 4.0000E-01 0.0000E+00 Unprotected Dose X/Q (s
  • m^-3) 4.6500E-06 3.1900E-04 1.7300E-06 1.0600E-06 3.6200E-07 7.7600E-08 0.0000E+00 is in compartment Location Breathing Time (hr) 0.OOOOE+00 7.2000E+02 USER SPECIFIED TIME Time 0.OOOOE+00 1.0000E+00 2.OOOOE+00 4.OOOOE+00 8.0000E+00 2.4000E+01 Rate Data Breathing Rate (mW3
  • sec^-l) 3.5000E-04 0.OOOOE+00 STEP DATA -

SUPPLEMENTAL TIME STEPS Time step 5.0000E-01 1.OOOOE+00 2.0000E+00 4.0000E+00 1.6000E+01 2.4000E+01 2

Calculation No. BNP-RAD-007 Revision I 1.2000E+02 1.2000E+02 7.2000E+02 O.OOOOE+00 Attachment No. 91 Page 91-13

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-14 RADTRAD Version 3.02 run on 4/04/2002 at 8:26:16

  1. ii#

it it it it i# it

        1. t#
  1. t it it###it it
    1. i##
        1. ti it it i#i#
  1. t Dose, Detailed model and Detailed Inventory Output BNP EAB Doses:

Time (h) 0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.OOOOE+00 0.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP LPZ Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid O.OOOOE+00 O.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP CR Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid 0.OOOOE+00 0.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 BNP CR - Unprotected Dose Doses:

Time (h)

=

0.0500 Delta dose (rem)

Accumulated dose (rem)

Whole Body 0.OOOOE+00 0.OOOOE+00 Thyroid O.OOOOE+00 O.OOOOE+00 TEDE 0.OOOOE+00 0.OOOOE+00 Environment Integral Nuclide Release:

Time (h)

=

0.0500 Ci Environment Transport Group Inventory:

Time (h)

=

0.0500 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Present Release 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Release Rate/s 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Total Release 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 kg Atoms Bq

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-15 Aerosols (kg) 0.0000E+00 0.OOOOE+/-O0 0.OOOOE+O0 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

0.0500 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter o.OOOOE+00 o.0000E+00 o.OOOOE+00 o.0000E+00 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

0.0500 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

0.0500 Noble gases (atois)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.0000E+00 0.OOOOE+00 O.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

0.0500 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

=

0.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.0158E-04 1.0158E-04 Thyroid 1.2317E-03 1.2317E-03 TEDE 1.5271E-04 1.5271E-04 BNP LPZ Doses:

Time (h)

=

0.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 9.7939E-05 9.7939E-05 Thyroid 1.1876E-03 1.1876E-03 TEDE 1.4724E-04 1.4724E-04 BNP CR Doses:

Time (h)

=

0.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.1189E-30 3.1189E-30 Thyroid 6.4283E-28 6.4283E-28 TEDE 2.9810E-29

2. 9810E-29 BNP CR -

Unprotected Dose Doses:

Calculation No. BNP-RAD-007 Revision I Time (h)

=

0.3000 Whole Body Delta dose (rem) 1.3012E-04 Accumulated dose (rem) 1.3012E-04 Attachment No. 91 Thyroid 1.5778E-03 1.5778E-03 Page 91-16 TEDE 1.9562E-04 1.9562E-04 Environment Integral Nuclide Release:

Ci

9. 0421E-01 1.7179E+01 2.9961E+01
4. 5531E+01
1. 5735E-03
6. 3262E-01
8. 6925E-01 1.2890E+00 1.1805E+00
1. 1840E+00 1.3247E+02 6.3529E+01 1.4327E-01 4.7811E-02 9.1195E-02 kg 2.3047E-06 2.0875E-09 1.0577E-09 3.6311E-09 1.9339E-11 5.1028E-09 8.4212E-11 1.1379E-09 4.4252E-11 3.3715E-10 7.0771E-07 2.4877E-08 1.1073E-07
6. 5234E-10 1.0484E-06 Atoms 1.6328E+19 1.4790E+16 7.3217E+15 2.4849E+16 1.3542E+14
2. 3458E+16 3.8419E+14 5.1522E+15 1.9887E+14
1. 5040E+15 3.2045E+18 1.1097E+17
4. 9766E+17
2. 8886E+15
4. 6086E+18 Bq 3.3456E+10
6. 3563E+11 1.108-6E+12 1.6846E+12 5.8221E+07 2.3407E+10 3.2162E+10 4.7692E+10 4.3678E+10 4.3809E+10
4. 9014E+12 2.3506E+12 5.3011E+09 1.7690E+09 3.3742E+09 Environment Transport Group Inventory:

Time (h)

=

0.3000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 1.9695E+19 1.5674E+15 4.8478E+13 1.1662E-06 Release Rate/s 1.8236E+16 1.4513E+12

4. 4887E+10 1.0798E-09 Total Release 1.9695E+19 1.5674E+15 4.8478E+13 1.1662E-06 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

0.3000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 1.5518E+17 4.7993E+15 1.1546E-04 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h) 0.3000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

0.3000 Noble gases (atoms)

Elemental I (atoms)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.3000 Time (h)

Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-17 Organic I (atoms)

Aerosols (kg) 0.OOOOE+00 o.OOOOE+00 BNP Control Room to Environment - CR Exh Transport Group Inventory:

Time (h)

=

0.3000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter o-OOOOE+00 o.OOOOE+00 o.OOOOE+00 o.OOOOE+00 BNP EAB Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.7565E-04 2.7722E-04 Thyroid 2.0904E-03 3.3221E-03 TEDE 2.6234E-04 4.1505E-04 BNP LPZ Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.6936E-04 2.6730E-04 Thyroid

2. 0155E-03 3.2031E-03 TEDE 2.5295E-04
4. 0018E-04 BNP CR Doses:

Time (h)

=

0.5000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.1080E-29 1.4199E-29 Thyroid 2.2605E-27 2.9034E-27 TEDE 1.0488E-28 1.3469E-28 BNP CR - Unprotected Dose Doses:

Time (h)

=

0.5000 Whole Body Delta dose (rem) 2.2500E-04 Accumulated dose (rem) 3.5512E-04 Thyroid 2.6778E-03 4.2556E-03 TEDE 3.3606E-04 5.3167E-04 Environment Integral Nuclide Release:

Ci 2.5576E+00 4.7572E+01 7.8727E+01 1.2456E+02 4.2409E-03 1.7090E+00 2.3019E+00 3.4680E+00 2.8761E+00

3. 1552E+00 3.7466E+02 1.8052E+02 3.8622E-01 1.2885E-01 2.4584E-01 kg 6.5189E-06 5.7806E-09 2.7793E-09 9.9336E-09 5.2120E-11 1.3785E-08 2.2301E-10 3.0615E-09 1.0781E-10 8.9843E-10 2.0016E-06 7.0690E-08 2.9851E-07 1.7580E-09 2.8263E-06 Atoms 4.6186E+19 4.0955E+16
1. 9239E+16 6.7979E+16
3. 6497E+14 6.3370E+16 1.0174E+15 1.3862E+16 4.8453E+14
4. 0077E+15
9. 0630E+18
3. 1534E+17
1. 3415E+18 7.7845E+15
1. 2424E+19 Bq 9.4631E+10 1.7602E+12 2.9129E+12 4.6087E+12 1.5691E+08
6. 3232E+10 8.5172E+10 1.2832E+11 1.0642E+11 1.1674E+11 1.3862E+13
6. 6794E+12 1.4290E+10 4.7673E+09 9.0959E+09 Environment Transport Group Inventory:

A 0.5000 Time (h)

Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-18 Time (h)

=

0.5000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 5.5706E+19 4.4284E+15 1.3696E+14 3.1438E-06 Release Rate/s 3.0948E+16 2.4602E+12

7. 6089E+10 1.7465E-09 Total Release 5.5706E+19 4.4284E+15 1.3696E+14 3.1438E-06 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

0.5000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 4.3841E+17 1.3559E+16 3.1124E-04 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

0.5000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 E

Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

0.5000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment - CR Exh Transport Group Inventory:

Time (h)

=

0.5000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.00003E+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

=

1.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.0068E-03 2.2840E-03 Thyroid 1.2316E-02 1.5638E-02 TEDE 2.6090E-03 3.0240E-03 BNP LPZ Doses:

Time (h)

=

1.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.9349E-03 2.2022E-03 Thyroid 1.1875E-02 1.5078E-02 TEDE

2. 5155E-03
2. 9157E-03 BNP CR Doses:

Calculation No. BNP-RAD-007 Revision 1 Time (h)

=

1.0000 Whole Body Delta dose (rem) 1.5535E-28 Accumulated dose (rem) 1.6955E-28 BNP CR - Unprotected Dose Doses:

Time (h)

=

1.0000 Whole Body Delta dose (rem) 2.5707E-03 Accumulated dose (rem) 2.9258E-03 Attachment No. 91 Thyroid

2. 1364E-26 2.4268E-26 Thyroid 1.5777E-02 2.0033E-02 Page 91-19 TEDE
1. 1204E-27 1.2551E-27 TEDE 3.3421E-03 3.8738E-03 Environment Integral Nuclide Release:

Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 1.0000 Ci 1.7816E-04

2. 1331E-04 2.4086E+01
4. 1935E+02
5. 8910E+02
1. 0572E+03
1. 8155E-02 2.4419E-01 2.7136E-02
2. 8684E-01
2. 6366E-01
3. 6588E-04 3.1580E-03 1.6664E-02 3.5992E-03 4.5637E-03 4.5700E-03 4.5767E-03 5.8784E-02 5.2012E-02 4.7876E-02 2.8248E-02 1.7833E-02 3.0420E-02 6.6235E-02 1.7370E-01 6.6028E-02
8. 8361E-03 1.8449E-01 2.9382E-02 8.8403E-02 8.8361E-01 7.9428E+00 1.0356E+01 1.5944E+01
1. 0173E+01 1.4136E+01 3.5264E+03
1. 7143E+03 1.6543E+00
5. 5147E-01 1.0530E+00 2.9518E-01 4.4298E-01 kg 5.6029E-12 1.8870E-10 6.1392E-05 5.0957E-08 2.0797E-08 8.4312E-08 2.2313E-10 8.4053E-09 1.9893E-07 7.9128E-11 2.0977E-11 6.7250E-13 1.2877E-10 1.7318E-12 1.0788E-12 2.1243E-10 2.3906E-12 1.1704E-10 1.2257E-10
9. 8914E-12 1.4834E-09
4. 2023E-12 5.3303E-09 3.6040E-11 2.4802E-10 3.0889E-11 2.5019E-11 9.3677E-10 8.8094E-12 9.7534E-10 1.1086E-10 2.9105E-09 6.4068E-08 1.0033E-09 1.4075E-08 3.8135E-10
4. 0251E-09 1.8840E-05 6.7131E-07 1.2786E-06 7.5244E-09 1.2106E-05 1.8046E-11 6.0510E-09 Atoms 5.8174E+13 1.8940E+15 4.3495E+20
3. 6103E+17 1.4396E+17 5.7698E+17
1. 5625E+15 5.6874E+16 1.3311E+18
5. 2365E+14 1.3731E+14 4.4999E+12 8.5219E+14 1.1336E+13
6. 9856E+12
1. 3466E+15 1.4842E+13 7.4193E+14 7.4556E+14 6.0169E+13
8. 6732E+15 2.4102E+13 3.0283E+16 2.0670E+14 1.1761E+15 1.4420E+14 1.1864E+14 4.4420E+15 4.1125E+13
4. 5532E+15
5. 0964E+14
1. 3278E+16
2. 9452E+17
4. 5773E+15 6.3729E+16 1.7139E+15 1.7956E+16 8.5304E+19
2. 9946E+18 5.7462E+18
3. 3318E+16 5.3215E+19 7.8184E+13 2.6028E+16 Bq
6. 5919E+06 7.8923E+06 8' 9118E+11
1. 5516E+13
2. 1797E+13 3.9117E+13 6.7175E+08
9. 0351E+09 1.0040E+09
1. 0613E+10 9.7555E+09 1.3538E+07
1. 1685E+08
6. 1656E+08 1.3317E+08 1.6886E+08 1.6909E+08 1.6934E+08 2.1750E+09 1.9244E+09 1.7714E+09 1.0452E+09 6.5981E+08 1.1255E+09 2.4507E+09 6.4269E+09 2.4430E+09 3.2694E+08
6. 8261E+09 1.0872E+09 3.2709E+09 3.2694E+10 2.9388E+ll 3.8319E+11 5.8992E+11 3.7641E+1I 5.2302E+11 1.3048E+14 6.3431E+13 6.1209E+10 2.0404E+10 3.8961E+10 1.0922E+10 1.6390E+10

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-20 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 6.5938E-03 3.5855E-03 2.7279E-03 1.0535E-02

9. 5661E-03
8. 6714E-03 3.7893E-03 1.6746E-03 1.2338E-01 2.5644E-05 2.7979E-06 3.7300E-06 1.0747E-03 5.3815E-07 1.2494E-04 6.5554E-06
1. 1863E-11
6. 3400E-13
1. 9056E-13
3. 6974E-10
1. 4405E-11 2.7188E-09
5. 6272E-11
2. 0700E-11 5.3184E-10 1.4979E-09
4. 5013E-08 1.6369E-08 1.0433E-08 1.5680E-10 3.7696E-11 8.1029E-11
5. 1029E+13 2.7078E+12 8.0816E+II 1.5792E+15
6. 0663E+13 1.1370E+16 2.3698E+14 8.4802E+13 1.3401E+15 3.7902E+15
1. 1342E+17 4.1074E+16
2. 6069E+16
3. 9180E+14 9.3806E+13
1. 9999E+14 Environment Transport Group Inventory:

Time (h)

=

Noble gases Elemental I 1.0000 (atoms)

(atoms)

Organic I (atoms)

Aerosols (kg)

A Present Release 5.2454E+20 2.0751E+16 6.4180E+14 1.3776E-05 Release Rate/s 1.4571E+17 5.7643E+12 1.7828E+11 3.8266E-09 Total Release 5.2454E+20 2.0751E+16

6. 4180E+14 1.3776E-05 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

1.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 2.0544E+18 6.3538E+16 1.3638E-03 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

1.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

1.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Pathway Time (h)

=

1.0000 Filter 2.4397E+08 1.3266E+08 1.0093E+08 3.8981E+08

3. 5394E+08 3.2084E+08
1. 4020E+08
6. 1961E+07
4. 5651E+09 9 4882E+05
1. 0352E+05 1.3801E+05 3.9764E+07 1.9912E+04 4.6226E+06 2.'4255E+05

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-21 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg) o.OOOOE+00 o.0000E+00 o.0000E+00 0.0000E+00 BNP EAB Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 8.1347E-03 1.0419E-02 Thyroid 4.3115E-02 5.8754E-02 TEDE 1.0424E-02 1.3448E-02 BNP LPZ Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 7.8434E-03 1.0046E-02 Thyroid 4.1571E-02 5.6650E-02 TEDE

1. 0051E-02 1.2966E-02 BNP CR Doses:

Time (h)

=

1.8000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3360E-27 1.5055E-27 Thyroid 1.3860E-25 1.6287E-25 TEDE 8.3259E-27 9.5810E-27 BNP CR - Unprotected Dose Doses:

Time (h)

=

Delta dose Accumulated A

1.8000 Whole Body rem) 1.0421E-02 dose (rem) 1.3346E-02 Thyroid 5.5230E-02 7.5263E-02 TEDE 1.3353E-02 1.7227E-02 Environment Integral Nuclide Release:

Ci

1. 1538E-03 1.3817E-03 1.2659E+02
2. 0226E+03
2. 3094E+03
4. 8568E+03 6.3608E-02
1. 5813E+00
1. 7577E-01
1. 7884E+00
1. 4969E+00
2. 8565E-03
2. 0547E-02 1.7225E-01
2. 2491E-02
2. 9554E-02
2. 8973E-02
2. 9645E-02
3. 7868E-01 3.3684E-01
3. 10OOE-01
1. 6872E-01
1. 1551E-01
1. 9681E-01 4.2735E-01 kg 3.6285E-11 1.2223E-09 3.2266E-04 2.4577E-07
8. 1532E-08 3.8733E-07
7. 8174E-10 5.4429E-08 1.2886E-06 4.9336E-10 1.1909E-10 5.2502E-12 8.3784E-10 1.7901E-i1 6.7414E-12 1.3757E-09
1. 5156E-11 7.5813E-10 7.8955E-10 6.4060E-11 9.6052E-09 2.5099E-11 3.4525E-08 2.3317E-10 1.6002E-09 Atoms 3.7674E+14 1.2268E+16 2.2860E+21 1.7413E+18
5. 6436E+17
2. 6506E+18 5.4741E+15
3. 6829E+17 8.6222E+18 3.2649E+15 7.7954E+14 3.5131E+13
5. 5446E+15
1. 1717E+14 4.3653E+13 8.7208E+15 9.4092E+13
4. 8058E+15
4. 8028E+15
3. 8967E+14
5. 6159E+16 1.4395E+14
1. 9615E+17 1.3373E+15 7.5881E+15 Bq 4.2690E+07
5. 1122E+07
4. 6839E+12
7. 4836E+13
8. 5449E+13
1. 7970E+14 2.3535E+09
5. 8507E+10
6. 5035E+09
6. 6172E+10
5. 5385E+10
1. 0569E+08 7.6025E+08
6. 3731E+09
8. 3218E+08
1. 0935E+09
1. 0720E+09
1. 0969E+09
1. 4011E+10
1. 2463E+10
1. 1470E+10
6. 2425E+09
4. 2738E+09 7.2819E+09 1.5812E+10 1.8000 Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-22 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 1.0352E+00 4.2697E-01 5.7239E-02 1.1369E+00 1.9035E-01

5. 6572E-01 5.6970E+00 2.9662E+01 3.6794E+01
5. 8573E+01 2.5568E+01
4. 9956E+01 1.8512E+04 8.9972E+03 5.8006E+00
1. 9314E+00 3.6923E+00 1.4831E+00 2.8660E+00 5.5279E-02
2. 1194E-02 1.4066E-02 6.8229E-02
6. 1285E-02
5. 6166E-02 2.4565E-02 1.0832E-02
7. 9408E-01 1.6611E-04
1. 8124E-05 2.4161E-05
6. 9613E-03 3.4863E-06 8.0919E-04 4.2463E-05
1. 8408E-10
1. 6178E-10 6.0682E-09 5.4289E-11 6.3184E-09 7.0946E-10 1.8765E-08 2.3926E-07 3.5646E-09
5. 1706E-08 9.5843E-10 1.4225E-08 9.8900E-05 3.5232E-06 4.4833E-06 2.6352E-08 4.2449E-05 9.0673E-11 3.9148E-08
9. 9454E-11 3.7476E-12
9. 8260E-13 2.3945E-09
9. 2285E-11
1. 7610E-08
3. 6480E-10
1. 3390E-10 3.4229E-09
9. 7028E-09
2. 9159E-07
1. 0603E-07
6. 7578E-08
1. 0158E-09 2.4415E-10 5.2486E-10 8.5936E+14 7.6716E+14 2.8775E+16
2. 5344E+14
2. 9497E+16 3.2614E+15 8.5611E+16 1.0999E+18 1.6262E+16 2.3412E+17 4.3073E+15
6. 3456E+16 4.4781E+20
1. 5716E+19 2.0148E+19
1. 1669E+17
1. 8659E+20
3. 9284E+14
1. 6840E+17
4. 2780E+14
1. 6006E+13
4. 1671E+12
1. 0227E+16
3. 8864E+14 7.3645E+16
1. 5363E+15 5.4855E+14
8. 6247E+15 2.4551E+16 7.3474E+17
2. 6606E+17
1. 6886E+17 2.5383E+15 6.0757E+14 1.2954E+15 Environment Transport Group Inventory:

Time (h)

=

Noble gases Elemental I 1.8000 (atoms)

(atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 2.7566E+21 7.7397E+16 2.3937E+15 4.9223E-05 Release Rate/s 4.2540E+17

1. 1944E+13
3. 6940E+Il 7.5961E-09 Total Release 2.7566E+21 7.7397E+16 2.3937E+15 4.9223E-05 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

1.8000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 7.6623E+18 2.3698E+17 4.8731E-03 Environment to BNP Control Room -

Normal Transport Group Inventory:

Pathway

3. 8301E+10
1. 5798E+10 2.1178E+09
4. 2067E+10 7.0428E+09 2.0932E+10 2. 1079E+II 1.0975E+12 1.3614E+12
2. 1672E+12 9.4600E+II
1. 8484E+12
6. 8495E+14 3.3290E+14
2. 1462E+II 7-1461E+10 1.3662E+lI 5.4876E+10 1.0604E+II 2.0453E+09 7.8419E+08 5.2044E+08 2.5245E+09 2.2675E+09 2.0782E+09 9.0892E+08 4.0080E+08 2.9381E+10 6.1460E+06 6.7061E+05 8.9396E+05 2.5757E+08 1.2899E+05 2.9940E+07
1. 5711E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-23 Time (h)

=

1.8000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

1.8000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

1.8000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

BNP EAB Doses:

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00

.A Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.4488E-02 5.4907E-02 Thyroid 2.3455E-01 2.9331E-01 TEDE 5.7183E-02

7. 0631E-02 BNP LPZ Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.4297E-02 2.4343E-02 Thyroid 7.5378E-02 1.3203E-01 TEDE 1.8377E-02 3.1343E-02 BNP CR Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 6.3158E-27 7.8214E-27 Thyroid

5. 6154E-25 7.2441E-25 TEDE 3.6563E-26 4.6144E-26 BNP CR - Unprotected Dose Doses:

Time (h)

=

2.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.4259E-01 2.5594E-01 Thyroid 1.2790E+00 1.3543E+00 TEDE 3.1182E-01 3.2905E-01 Environment Integral Nuclide Release:

Time (h)

=

2.0000 Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Ci 1.5126E-03

1. 8115E-03 1.6531E+02 2.5872E+03
2. 8148E+03
6. 1414E+03 kg 4.7570E-11 1.6026E-09 4.2134E-04 3.1438E-07 9.9373E-08 4.8977E-07 Atoms 4.9392E+14 1.6085E+16 2.9851E+21 2.2274E+18 6.8786E+17 3.3517E+18 Bq 5.5968E+07 6.7026E+07 6.1163E+12
9. 5727E+13 1.0415E+14 2.2723E+14

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-24 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244

7. 8703E-02
2. 0730E+00
2. 3045E-01
2. 3230E+00
1. 9007E+00
3. 8951E-03
2. 6966E-02 2.4175E-01 2.9230E-02 3.8746E-02 3.7786E-02 3.8867E-02 4.9581E-01 4.4158E-01
4. 0640E-01
2. 1687E-01
1. 5144E-01 2.5792E-01
5. 5975E-01 1.3299E+00
5. 5955E-01 7.5046E-02 1.4712E+00 2.4956E-01 7-3951E-01 7.4608E+00 3.7011E+01 4.5365E+01 7.2797E+01 2.9135E+01 6.1518E+01 2.4166E+04
1. 1737E+04 7.1786E+00 2.3895E+00 4.5695E+00 1.8297E+00 3.7565E+00 7.6342E-02 2.7175E-02 1.7458E-02 8.9450E-02
8. 0132E-02 7.3638E-02 3.2214E-02 1.4197E-02 1.0395E+00
2. 1778E-04 2.3763E-05
3. 1677E-05
9. 1270E-03 4.5711E-06 1.0609E-03 5.5673E-05 9.6726E-10 7.1356E-08 1.6894E-06 6.4082E-10 1.5122E-10
7. 1593E-12 1.0996E-09 2.5124E-11 8.7612E-12 1.8036E-09 1.9766E-11 9.9397E-10 1.0338E-09 8.3980E-11 1.2592E-08 3.2262E-11 4.5265E-08
3. 0558E-10 2.0960E-09 2.3649E-10
2. 1202E-10 7.9561E-09 7.0251E-11 8.2842E-09 9.2740E-10 2.4575E-08 2.9854E-07 4.3949E-09 6.4263E-08 1.0921E-09 1.7517E-08 1.2911E-04 4.5959E-06 5.5483E-06 3.2603E-08 5.2534E-05 1.1186E-10 5.1312E-08 1.3735E-10 4.8051E-12 1.2196E-12 3.1393E-09 1.2067E-10 2.3088E-08 4.7838E-10 1.7550E-10 4.4806E-09 1.2721E-08 3.8231E-07 1.3902E-07 8.8600E-08 1.3318E-09 3.2010E-10 6.8814E-10 6.7732E+15
4. 8283E+17
1. 1305E+19 4.2408E+15
9. 8985E+14 4.7905E+13 7.2768E+15
1. 6446E+14
5. 6732E+13 1.1433E+16 1.2271E+14 6.3009E+15 6.2884E+15
5. 1085E+14 7.3623E+16 1.8504E+14 2.5716E+17 1.7526E+15
9. 9390E+15
1. 1040E+15
1. 0054E+15 3.7726E+16 3.2795E+14
3. 8673E+16 4.2633E+15 1.1212E+17 1.3724E+18 2.0050E+16
2. 9098E+17
4. 9082E+15
7. 8142E+16 5.8458E+20 2.0502E+19 2.4935E+19 1.4437E+17 2.3092E+20 4.8464E+14 2.2072E+17
5. 9080E+14
2. 0523E+13
5. 1721E+12
1. 3408E+16
5. 0816E+14
9. 6554E+16
2. 0146E+15
7. 1895E+14
1. 1290E+16
3. 2189E+16
9. 6333E+17
3. 4882E+17
2. 2140E+17 3.3280E+15 7.9656E+14 1.6984E+15 Environment Transport Group Inventory:
2. 9120E+09
7. 6703E+10 8.5267E+09 8.5950E+10
7. 0327E+10 1.4412E+08 9.9775E+08 8.9449E+09
1. 0815E+09 1.4336E+09 1.3981E+09 1.4381E+09 1.8345E+10
1. 6339E+10
1. 5037E+10 8 '0241E+09 5.6032E+09 9.5432E+09 2.0711E+10
4. 9206E+10
2. 0703E+10 2.7767E+09 5.4435E+10 9.2339E+09 2.7362E+10 2.7605E+11 1.3694E+12
1. 6785E+12
2. 6935E+12
1. 0780E+12 2.2762E+12 8.9415E+14 4.3426E+14
2. 6561E+11 8.8413E+10
1. 6907E+11 6.7700E+I10 1.3899E+11 2.8246E+09 1.0055E+09 6.4595E+08 3.3096E+09 2.9649E+09 2.7246E+09
1. 1919E+09 5.2530E+08 3.8460E+10 8.0580E+06 8.7924E+05
1. 1721E+06 3.3770E+08 1.6913E+05 3.9253E+07 2.0599E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-25 Time (h)

=

2.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 3.5995E+21 9.7385E+16 3.0119E+15 6.1064E-05 Release Rate/s 4.9994E+17 1.3526E+13

4. 1832E+11 8.4811E-09 Total Release 3.5995E+21 9.7385E+16 3.0119E+15
6. 1064E-05 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

2.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 9.6411E+18 2.9818E+17 6.0454E-03 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

2.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 E

Environment to BNP Control Room Normal Transport Group Inventory:

Time (h)

=

2.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

2.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

BNP EAB Doses:

Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Whole Body 6.7239E-02 1.2215E-01 Thyroid 3.4117E-01 6.3448E-01 TEDE 8.5729E-02 1.5636E-01 BNP LPZ Doses:

Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.1608E-02 4.5951E-02 Thyroid 1.0964E-01 2.4167E-01 TEDE 2.7550E-02 5.8894E-02 BNP CR Doses:

Calculation No. BNP-RAD-007 Revision 1 Time (h) =

2.3000 Whole Body Delta dose (rem) 3.0676E-26 Accumulated dose (rem) 3.8497E-26 BNP CR - Unprotected Dose Doses:

Attachment No. 91 Thyroid 2.7367E-24 3.4611E-24 Page 91-26 TEDE 1.7884E-25 2.2498E-25 Time (h)

=

2.3000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.6665E-01 6.2259E-01 Thyroid 1.8604E+00 3.2147E+00 TEDE

4. 6748E-01 7.9653E-01 Environment Integral Nuclide Release:

Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 2.3000 Ci 2.0391E-03 2.4422E-03 2.2730E+02 3.4574E+03 3.5220E+03 8.0777E+03

1. 0056E-01 2.7945E+00 3.1068E-01 3.0935E+00 2.4576E+00 5.5814E-03 3.6414E-02 3.5983E-01 3.8954E-02 5.2232E-02 5.0589E-02 5.2399E-02 6.6723E-01
5. 9522E-01 5.4782E-01 2.8489E-01
2. 0416E-01 3.4750E-01
7. 5366E-01 1.7458E+00 7.5393E-01 1.0118E-01 1.9487E+00 3.3646E-01
9. 9307E-01
1. 0043E+01 4.7728E+01 5.7343E+01
9. 3390E+01 3.3432E+01 7.7967E+01 3.3212E+04 1.6085E+04
9. 1745E+00 3.0528E+00 5.8400E+00 2.2799E+00 5.0624E+00 kg 6.4127E-11
2. 1605E-09 5.7935E-04
4. 2012E-07 1.2434E-07
6. 4420E-07
1. 2359E-09
9. 6189E-08 2.2776E-06 8.5338E-10
1. 9552E-10
1. 0259E-11 1.4848E-09 3.7396E-11 1.1676E-11 2.4313E-09
2. 6463E-11 1.3400E-09 1.3912E-09
1. 1320E-10 1.6974E-08 4.2381E-11
6. 1024E-08 4.1171E-10 2.8222E-09
3. 1045E-10 2.8568E-10 1.0726E-08 9.3051E-11
1. 1169E-08 1.2454E-09 3.3081E-08 3.8498E-07 5.5553E-09 8.2441E-08 1.2532E-09 2.2201E-08 1.7743E-04 6.2987E-06 7.0909E-06
4. 1653E-08 6.7140E-05 1.3939E-10
6. 9150E-08 Atoms
6. 6583E+14 2. 1685E+16 4.1046E+21 2.9765E+18 8.6069E+17 4.4084E+18 8.6541E+15
6. 5086E+17
1. 5240E+19
5. 6475E+15 1.2798E+15
6. 8644E+13
9. 8262E+15 2.4478E+14 7.5605E+13 1.5412E+16 1.6429E+14
8. 4945E+15
8. 4625E+15
6. 8858E+14
9. 9242E+16 2.4307E+14 3.4669E+17 2.3613E+15
1. 3382E+16 1.4493E+15
1. 3546E+15
5. 0862E+16 4.3439E+14 5.2139E+16 5.7251E+15 1.5092E+17 1.7698E+18
2. 5345E+16 3.7329E+17
5. 6322E+15
9. 9035E+16
8. 0341E+20
2. 8098E+19
3. 1868E+19
1. 8444E+17
2. 9513E+20 6.0389E+14
2. 9745E+17 Bq 7.5447E+07 9.0361E+07 8'4101E+12 1.2792E+14 1.3032E+14 2.9888E+14 3.7207E+09
1. 0340E+11 1.1495E+10
1. 1446E+11
9. 0931E+10
2. 0651E+08 1.3473E+09 1.3314E+10 1.4413E+09 1.9326E+09
1. 8718E+09 1.9388E+09 2.4688E+10 2.2023E+10 2.0269E+10
1. 0541E+10 7.5539E+09 1.2858E+10 2.7886E+10 6.4593E+10
2. 7895E+10 3.7435E+09 7.2102E+10 1.2449E+10 3.6744E+10 3.7159E+11 1.7659E+12 2.1217E+12 3.4554E+12 1.2370E+12
2. 8848E+12
1. 2289E+15 5.9515E+14 3.3946E+11 1.1295E+11
2. 1608E+11 8.4357E+10 1.8731E+11

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-27 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 1.1142E-01 3.5581E-02 2.1921E-02 1.2058E-01 1.0765E-01 9.9274E-02 4.3442E-02 1.9132E-02 1.3984E+00

2. 9361E-04 3.2037E-05 4.2706E-05 1.2305E-02
6. 1628E-06 1.4302E-03 7.5055E-05
2. 0046E-10
6. 2916E-12
1. 5313E-12 4.2319E-09
1. 6210E-10
3. 1125E-08 6.4513E-10
2. 3649E-10
6. 0279E-09 1.7150E-08
5. 1543E-07
1. 8742E-07
1. 1945E-07 1.7956E-09
4. 3153E-10
9. 2772E-10
8. 6228E+14
2. 6871E+13
6. 4943E+12 1.8075E+16 6.8264E+14 1.3017E+17 2.7168E+15 9.6882E+14 1.5189E+16 4.3395E+16 1.2987E+18 4.7027E+17
2. 9847E+17 4.4868E+15 1.0739E+15 2.2897E+15 Environment Transport Group Inventory:

Time (h)

=

Noble gases Elemental I 2.3000 (atoms)

(atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 4.9494E+21 1.2911E+17 3.9930E+15 7.8226E-05 Release Rate/s 5.9775E+17

1. 5592E+13 4.8224E+11 9.4476E-09 Total Release
4. 9494E+21 1.2911E+17
3. 9930E+15 7.8226E-05 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

2.3000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 1.2781E+19 3.9530E+17 7.7444E-03 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

2.3000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

2.3000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.0000E+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment - CR Exh Transport Group Inventory:

Pathway Time (h)

=

2.3000 Filter 4.1226E+09 1 3165E+09

8. 1109E+08 4.4616E+09
3. 9829E+09 3 6731E+09
1. 6074E+09
7. 0787E+08
5. 1742E+10
1. 0863E+07
1. 1854E+06
1. 5801E+06
4. 5527E+08 2.2802E+05 5.2918E+07 2.-7770E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-28 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kq) o.0000E+00 o.0000E+00 0.0000E+00 o.0000E+00 BNP EAB Doses:

Time (h)

=

4.0000 Delta dose (rem)

Accumulated dose (rem)

BNP LPZ Doses:

Time (h)

=

4.0 Delta dose (rem)

Accumulated dose BNP CR Doses:

Whole Body 1.8934E-02 1.4108E-01 000 Whole Body 1.0015E-02 (rem) 5.5966E-02 Time (h)

=

4.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.0297E-25 2.4147E-25 Thyroid 5.6085E-02 6.9056E-01 Thyroid 2.9665E-02 2.7133E-01 Thyroid 1.9960E-23 2.3422E-23 TEDE

2. 1892E-02 1.7825E-01 TEDE 1.1579E-02 7.0473E-02 TEDE 1.2882E-24
1. 5132E-24 BNP CR -

Unprotected Dose Doses:

Time (h)

=

4.0000 Whole Body Delta dose (rem) 9.0237E-03 Accumulated dose (rem) 6.3161E-01 Thyroid 2.6729E-02 3.2414E+00 TEDE 1.0434E-02 8.0696E-01 Environment Integral Nuclide Release:

Ci 3.3492E-03

4. 0119E-03 5.7854E+02 7.6924E+03 5.9267E+03 1.6732E+04 1.5489E-01 4.5895E+00
5. 1039E-01 4.9050E+00 3.5977E+00
1. 1442E-02 6.0223E-02
7. 8424E-01 6.1891E-02 8.5786E-02
8. 1446E-02 8.6080E-02 1.0904E+00 9.7705E-01 8.9961E-01
4. 3493E-01 3.3538E-01 5.6945E-01 1.2335E+00 kg 1.0533E-10 3.5492E-09 1.4746E-03 9.3473E-07 2.0923E-07 1.3344E-06 1.9036E-09 1.5797E-07 3.7416E-06 1.3531E-09 2.8622E-10 2.1030E-11 2.4557E-09
8. 1502E-11
1. 8551E-11 3.9932E-09 4.2605E-11 2.2014E-09
2. 2735E-09 1.8581E-10 2.7874E-08 6.4702E-11 1.0025E-07 6.7466E-10
4. 6189E-09 Atoms 1.0936E+15 3.5623E+16
1. 0447E+22
6. 6224E+18 1.4483E+18
9. 1317E+18 1.3330E+16 1.0689E+18 2.5036E+19 8.9545E+15 1.8736E+15 1.4072E+14 1.6251E+16 5.3350E+14 1.2012E+14 2.5313E+16 2.6451E+14 1.3955E+16 1.3830E+16 1.1303E+15 1.6297E+17 3.7109E+14 5.6952E+17 3.8694E+15 2.1902E+16 Bq 1.2392E+08 1.4844E+08
2. 1406E+13
2. 8462E+14 2.1929E+14 6.1909E+14 5.7311E+09
1. 6981E+11
1. 8884E+10
1. 8149E+11 1.3311E+11 4.2334E+08 2.2282E+09
2. 9017E+10 2.2900E+09
3. 1741E+09 3.0135E+09
3. 1850E+09
4. 0345E+10
3. 6151E+10 3.3286E+10 1.6092E+10
1. 2409E+10
2. 1070E+10 4.5639E+10 4.0000 Time (h)

Co-58 Co-60 Rr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-29 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 2.6602E+00 1.2364E+00 1.6622E-01 3.0342E+00

5. 5273E-01
1. 6128E+00
1. 6426E+01
7. 6471E+01 8.4164E+01 1.4730E+02
3. 9878E+01
1. 1862E+02 8.4222E+04 3.9279E+04 1.4142E+01 4.7007E+00 9.0023E+00 3.0522E+00 8.3070E+00 2.4131E-01 5.3843E-02 2.9868E-02 1.9803E-01 1.7501E-01
1. 6308E-01
7. 1458E-02
3. 1388E-02 2.2833E+00 4.8233E-04 5.2634E-05
7. 0157E-05
2. 0214E-02
1. 0126E-05 2.3493E-03 1.2330E-04 4.7305E-10 4.6849E-10 1.7622E-08 1.4488E-10 1.8348E-08 2.0226E-09 5.4105E-08 6.1683E-07
8. 1537E-09 1.3003E-07 1.4949E-09 3.3778E-08
4. 4995E-04
1. 5381E-05 1.0930E-05 6.4137E-08
1. 0350E-04
1. 8660E-10
1. 1347E-07
4. 3414E-10
9. 5208E-12
2. 0865E-12
6. 9501E-09 2.6353E-10 5.1130E-08
1. 0612E-09 3.8799E-10 9.8424E-09 2.8174E-08 8.4680E-07 3.0788E-07 1.9622E-07 2.9503E-09
7. 0885E-10 1.5240E-09 2.2084E+15 2.2215E+15 8.3559E+16
6. 7635E+14
8. 5654E+16 9.2980E+15 2.4684E+17
2. 8356E+18 3.7199E+16
5. 8877E+17 6.7182E+15 1.5068E+17
2. 0373E+21 6.8612E+19
4. 9123E+19
2. 8400E+17 4.5494E+20
8. 0845E+14 4.8809E+17 1.8675E+15 4.0663E+13
8. 8486E+12 2.9684E+16 1.1098E+15 2.1383E+17 4.4689E+15 1.5895E+15 2.4800E+16
7. 1289E+16
2. 1337E+18 7.7255E+17
4. 9033E+17 7.3721E+15 1.7640E+15 3.7615E+15 Environment Transport Group Inventory:

Time (h)

=

4.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 1.2597E+22 3.0882E+17 9.5512E+15 1.2094E-04 Release Rate/s 8.7478E+17 2.1446E+13 6.6328E+II 8.3989E-09 Total Release 1.2597E+22 3.0882E+17 9.5512E+15 1.2094E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

4.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 3.0573E+19 9.4557E+17 1.1973E-02 Environment to BNP Control Room - Normal Transport Group Inventory:

Pathway

9. 8426E+10 4.5746E+10 6.1500E+09 1.1226E+11
2. 0451E+10 5.9675E+10 6.0776E+II 2.8294E+12 3.1141E+12
5. 4502E+12
1. 4755E+12
4. 3891E+12 3 1162E+15
1. 4533E+15 5.2326E+11 17393E+II 3.3309E+11
1. 1293E+11
3. 0736E+11
8. 9285E+09
1. 9922E+09
1. 1051E+09
7. 3272E+09 6.4753E+09
6. 0339E+09
2. 6439E+09
1. 1614E+09
8. 4484E+10
1. 7846E+07
1. 9475E+06
2. 5958E+06 7.4790E+08 3.7465E+05 8.6925E+07 4.5621E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-30 Time (h)

=

4.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Filter 0.00003E+00 o.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

4.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.00003E+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

4.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

BNP EAB Doses:

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 A

Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.5913E-02 1.6699E-01 Thyroid 2.9609E-02 7.2017E-01 TEDE 2.7177E-02 2.0543E-01 BNP LPZ Doses:

Time (h)

=

8.0000 Delta dose (rem)

Accumulated dose (rem)

BNP CR Doses:

Time (h)

=

8.0 Delta dose (rem)

Accumulated dose Whole Body 1.3706E-02 6.9672E-02 000 Whole Body 2.8603E-25 (rem) 5.2750E-25 Thyroid 1.5661E-02 2.8700E-01 Thyroid 3.6829E-23 6.0250E-23 TEDE 1.4375E-02 8.4848E-02 TEDE 2.3115E-24 3.8246E-24 BNP CR - Unprotected Dose Doses:

Time (h)

=

8.0000 Whole Body Delta dose (rem) 1.2350E-02 Accumulated dose (rem) 6.4396E-01 Thyroid 1.4111E-02 3.2555E+00 TEDE 1.2952E-02 8.1991E-01 Environment Integral Nuclide Release:

Time (h)

=

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 8.0000 Ci 3.7203E-03 4.4571E-03 1.4046E+03 1.4185E+04 7.3238E+03 2.7217E+04 kg 1.1700E-10 3.9430E-09 3.5800E-03 1.7236E-06 2.5856E-07 2.1705E-06 Atoms 1.2148E+15 3.9575E+16 2.5364E+22 1.2212E+19 1.7897E+18 1.4854E+19 Bq 1.3765E+08 1.6491E+08 5.1969E+13 5.2483E+14 2.7098E+14 1.0070E+15

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-31 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 1.7025E-01 5.0978E+00

5. 6702E-01 5.3423E+00 3.7845E+00 1.4418E-02
6. 7184E-02 9.4480E-01 6.7480E-02 9.5292E-02 8.9435E-02 9.5631E-02 1.2076E+00 1.0845E+00 9.9921E-01
4. 6521E-01 3.7258E-01
6. 3120E-01 1.3673E+00 2.8430E+00 1.3720E+00
1. 8466E-01 3.2693E+00
6. 1404E-01 A

1.7798E+00 1.8200E+01 9.2387E+01 9.2466E+01 1.7489E+02

4. 0462E+01 1.3590E+02 2.0239E+05 8.3894E+04 1.5551E+01
5. 1657E+00 9.8991E+00
3. 1295E+00
9. 2224E+00
3. 1134E-01
5. 7375E-02 3.0750E-02 2.1996E-01
1. 9324E-01
1. 8117E-01 7.9453E-02
3. 4843E-02
2. 5275E+00 5.3585E-04 5.8477E-05 7.7941E-05 2.2456E-02
1. 1251E-05 2.6099E-03 1.3698E-04 2.0923E-09
1. 7547E-07
4. 1568E-06
1. 4737E-09 3.0109E-10
2. 6500E-11
2. 7395E-09 9.8189E-11
2. 0226E-11
4. 4357E-09
4. 6784E-11 2.4456E-09
2. 5179E-09
2. 0626E-10 3 0960E-08
6. 9207E-11
1. 1137E-07
7. 4782E-10
5. 1199E-09
5. 0557E-10
5. 1988E-10
1. 9577E-08
1. 5611E-10
2. 0383E-08 2.2319E-09 5.9950E-08 7.4521E-07
8. 9580E-09
1. 5438E-07
1. 5167E-09
3. 8698E-08 1.0813E-03 3.2852E-05
1. 2019E-05 7.0482E-08 1.1381E-04 1.9133E-10 1.2597E-07 5.6013E-10
1. 0145E-11
2. 1481E-12 7.7197E-09 2.9098E-10 5.6801E-08 1.1799E-09 4.3070E-10 1.0895E-08 3.1300E-08 9.4080E-07 3.4205E-07
2. 1800E-07 3.2780E-09
7. 8746E-10 1.6931E-09 1.4652E+16
1. 1873E+18 2.7814E+19 9.7528E+15 1.9709E+15 1.7732E+14 1.8130E+16 6.4272E+14 1.3097E+14 2.8118E+16 2.9045E+14 1.5503E+16 1.5316E+16 1.2546E+15 1.8102E+17 3.9693E+14
6. 3270E+17 4.2890E+15 2. 4278E+16 2.3602E+15 2.4652E+15
9. 2833E+16 7.2877E+14
9. 5153E+16 1.0260E+16 2.7351E+17 3.4258E+18
4. 0868E+16
6. 9904E+17 6.8164E+15 1.7263E+17 4.8959E+21 1.4655E+20
5. 4016E+19 3.1210E+17 5.0026E+20 8.2891E+14
5. 4188E+17 2.4094E+15 4.3330E+13
9. 1099E+12 3.2971E+16 1.2254E+15 2.3754E+17
4. 9689E+15 1.7644E+15 2.7452E+16
7. 9200E+16 2.3706E+18
8. 5827E+17 5.4473E+17
8. 1910E+15
1. 9596E+15 4.1788E+15 Environment Transport Group Inventory:
6. 2992E+09
1. 8862E+11
2. 0980E+10
1. 9766E+11 1.4003E+11
5. 3345E+08 2.4858E+09 3.4958E+10 2.4968E+09
3. 5258E+09 3. 3091E+09 3.5383E+09 4.4682E+10
4. 0128E+10
3. 6971E+10
1. 7213E+10 1.3786E+10 2.3354E+10
5. 0590E+10
1. 0519E+11 5.0765E+10
6. 8326E+09
1. 2096E+11 2.2719E+10
6. 5851E+10 6.7342E+11 3.4183E+12 3.4212E+12
6. 4708E+12
1. 4971E+12
5. 0284E+12
7. 4886E+15 3. 1041E+15
5. 7538E+11
1. 9113E+11 3.6627E+11
1. 1579E+11 3.4123E+11
1. 1519E+10
2. 1229E+09
1. 1378E+09
8. 1386E+09
7. 1497E+09
6. 7032E+09
2. 9398E+09
1. 2892E+09
9. 3518E+10
1. 9827E+07
2. 1636E+06
2. 8838E+06
8. 3089E+08
4. 1627E+05
9. 6565E+07 5.0683E+06

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-32 Time (h)

=

8.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 3.0581E+22 7.3145E+17 2.2622E+16 1.3306E-04 Release Rate/s

1. 0619E+18 2.5398E+13 7.8549E+11 4.6201E-09 Total Release
3. 0581E+22 7.3145E+17 2.2622E+16 1.3306E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

8.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 7.2414E+19 2.2396E+18 I 3173E-02 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

8.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.0000E+00 A

Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

8.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.000OE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

8.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

= 16.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.2654E-02 1.8965E-01 Thyroid 1.6196E-02 7.3637E-01 TEDE 2.3175E-02 2.2860E-01 BNP LPZ Doses:

Time (h)

=

16.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 8.8620E-03 7.8534E-02 Thyroid 6.3358E-03 2. 9333E-01 TEDE 9.0657E-03

9. 3913E-02 BNP CR Doses:

Calculation No. BNP-RAD-007 Revision 1 Time (h)

=

16.0000 Whole Body Delta dose (rem) 2.5995E-25 Accumulated dose (rem) 7.8746E-25 BNP CR - Unprotected Dose Doses:

Time (h)

=

16.0000 Whole Body Delta dose (rem) 6.6153E-03 Accumulated dose (rem) 6.5058E-01 Attachment No. 91 Thyroid 4.4556E-23

1. 0481E-22 Thyroid
9. 1963E-03 3.2647E+00 Page 91-33 TEDE 2.7638E-24 6.5884E-24 TEDE
6. 9109E-03 8.2682E-01 Environment Integral Nuclide Release:

Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 16.0000 Ci 3.7602E-03 4.5050E-03 3.0547E+03 1.9465E+04 7.4970E+03 3.2539E+04 1.7189E-01

5. 1524E+00 5.7311E-01 5.3755E+00 3.7907E+00 1.5034E-02 6.7971E-02
9. 5799E-01 6.7913E-02
9. 6312E-02
9. 0140E-02 9.6659E-02 1.2196E+00 1.0958E+00 1.0099E+00
4. 6678E-01 3.7658E-01
6. 3744E-01 1.3812E+00 2.8523E+00 1.3863E+00 1.8665E-01 3.2839E+00 6.2062E-01 1.7958E+00 1.8383E+01
1. 1053E+02 9.4563E+01 2. 0091E+02
4. 0474E+01
1. 4642E+02
4. 3070E+05
1. 4082E+05
1. 5702E+01
5. 2152E+00
9. 9956E+00
3. 1304E+00 9-3199E+00 kg
1. 1825E-10 3.9853E-09 7.7861E-03 2.3653E-06 2.6467E-07 2.5950E-06 2.1125E-09
1. 7735E-07
4. 2015E-06
1. 4829E-09
3. 0158E-10 2. 7633E-11 2. 7716E-09
9. 9559E-11
2. 0356E-11
4. 4832E-09
4. 7153E-I1 2.4719E-09 2.5429E-09
2. 0840E-10
3. 1291E-08
6. 9441E-11
1. 1256E-07 7.5521E-10
5. 1719E-09
5. 0722E-10 5.2530E-10 1.9788E-08 1.5681E-10
2. 0601E-08 2.2521E-09 6.0553E-08 8.9156E-07 9.1612E-09 1.7736E-07 1.5172E-09 4.1694E-08 2.3009E-03
5. 5144E-05 1.2136E-05
7. 1158E-08
1. 1492E-04 1.9138E-10 1.2731E-07 Atoms
1. 2278E+15
4. 0001E+16 5.5163E+22 1.6758E+19 1.8321E+18 1.7758E+19 1.4793E+16 1.2000E+18
2. 8113E+19 9.8134E+15
1. 9741E+15
1. 8490E+14
1. 8342E+16
6. 5169E+14 1.3181E+14 2.8420E+16
2. 9274E+14 1.5670E+16 1.5468E+16 1.2677E+15
1. 8295E+17
3. 9827E+14
6. 3949E+17
4. 3314E+15 2. 4524E+16 2.3679E+15 2.4909E+15 9.3831E+16 7.3202E+14
9. 6173E+16 1.0353E+16 2.7625E+17
4. 0985E+18
4. 1795E+16 8.0306E+17 6.8185E+15 1.8599E+17
1. 0419E+22 2-4599E+20 5.4542E+19 3.1509E+17
5. 0514E+20 8.2915E+14 5.4761E+17 Bq 1.3913E+08 1.6668E+08 1.1303E+14
7. 2020E+14 2.7739E+14 1.2040E+15 6.3598E+09
1. 9064E+11 2.1205E+10 1.9889E+11 1.4025E+11 5.5625E+08
2. 5149E+09
3. 5446E+10 2.5128E+09 3.5636E+09 3.3352E+09 3.5764E+09
4. 5126E+10
4. 0545E+10 3.7366E+10 1.7271E+10 1.3934E+10 2.3585E+10
5. 1103E+10 1.0553E+11 5.1294E+10 6.9061E+09
1. 2150E+11 2.2963E+10
6. 6445E+10
6. 8018E+11
4. 0896E+12
3. 4988E+12 7.4337E+12 1.4975E+12
5. 4177E+12 1.5936E+16
5. 2104E+15
5. 8099E+11
1. 9296E+11
3. 6984E+1l
1. 1582E+11 3.4483E+11

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-34 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 3.2611E-01 5.7541E-02 3.0763E-02 2.2231E-01 1.9501E-01 1.8311E-01 8.0324E-02

3. 5210E-02 2.5523E+00 5.4161E-04
5. 9106E-05 7.8779E-05 2.2698E-02 1.1372E-05 2.6379E-03 1.3845E-04 5.8672E-10 1.0175E-lI 2.1490E-12
7. 8022E-09 2.9365E-10
5. 7411E-08
1. 1928E-09
4. 3524E-10
1. 1002E-08
3. 1637E-08
9. 5092E-07 3.4572E-07 2.2034E-07
3. 3133E-09
7. 9591E-10 1.7113E-09
2. 5238E+15
4. 3456E+13
9. 1137E+12 3.3323E+16 1.2366E+15 2.4010E+17 5.0234E+15 1.7830E+15 2.7721E+16 8.0051E+16 2.3961E+18 8.6750E+17
5. 5059E+17 8.2793E+15 1.9806E+15
4. 2237E+15 Environment Transport Group Inventory:

Time (h)

=

Noble gases Elemental I 16.0000 (atoms)

(atoms)

Organic I (atoms)

Aerosols (kg) 1 Present Release 6.6509E+22 1.5758E+18 4.8735E+16 1.3436E-04 Release Rate/s 1.1547E+18 2.7357E+13 8.4609E+l1 2.3327E-09 Total Release 6.6509E+22

1. 5758E+18
4. 8735E+16 1.3436E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

= 16.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 1.5600E+20 4.8247E+18 1.3302E-02 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

= 16.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

16.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment - CR Exh Transport Group Inventory:

Pathway Time (h)

=

16.0000 Filter 1.2066E+10 2.1290E+09

1. 1382E+09 8.2255E+09 7.2153E+09 6.7751E+09 2.9720E+09 1.3028E+09 9-4434E+10 2.0040E+07 2.1869E+06 2.9148E+06 8.3982E+08 4.2076E+05 9.7601E+07
5. 1227E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-35 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 o.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.1232E-02 2.0088E-01 Thyroid 1.4358E-02 7.5073E-01 TEDE

1. 1675E-02 2.4028E-01 BNP LPZ Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.3936E-03 8.2928E-02 Thyroid

5. 6165E-03
2. 9895E-01 TEDE 4.5671E-03 9.8480E-02 BNP CR Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3452E-25 9.2198E-25 Thyroid 2.2702E-23 1.2751E-22 TEDE 1.4440E-24 8.0324E-24 BNP CR - Unprotected Dose Doses:

Time (h)

=

24.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.2798E-03 6.5386E-01 Thyroid

8. 1522E-03 3.2729E+00 TEDE 3. 5315E-03 8.3035E-01 Environment Integral Nuclide Release:

Ci 3. 7615E-03 4.5066E-03 4.7023E+03

2. 0915E+04 7.4988E+03 3.3227E+04 1.7194E-01 5.1542E+00 5.7331E-01
5. 3761E+00 3.7907E+00 1.5070E-02 6.7998E-02 9.5812E-01 6.7921E-02 9.6346E-02
9. 0157E-02 9 6693E-02 1.2200E+00
1. 0962E+00
1. 0102E+00 4.6679E-01 3.7672E-01
6. 3762E-01
1. 3816E+00 kg
1. 1829E-10 3.9868E-09
1. 1986E-02
2. 5415E-06 2 6473E-07
2. 6499E-06 2.1131E-09
1. 7741E-07 4.2030E-06
1. 4831E-09
3. 0158E-10 2.7699E-11 2.7727E-09
9. 9573E-11
2. 0358E-11 4.4848E-09
4. 7161E-11 2.4728E-09 2.5437E-09 2.0847E-10 3.1302E-08
6. 9443E-11
1. 1260E-07
7. 5542E-10 5.1735E-09 Atoms 1.2282E+15 4.0015E+16 8.4916E+22
1. 8006E+19
1. 8325E+18 1.8134E+19 1.4797E+16 1.2004E+18 2.8123E+19 9.8145E+15
1. 9741E+15
1. 8534E+14 1.8349E+16 6.5178E+14 1.3183E+14 2.8429E+16 2.9280E+14
1. 5675E+16 1.5473E+16 1.2681E+15 1.8301E+17 3.9828E+14 6.3972E+17 4.3326E+15 2.4532E+16 Bq 1.3917E+08 1.6674E+08 1.7399E+14 7.7386E+14 2.7745E+14 1.2294E+15 6.3618E+09
1. 9070E+11
2. 1213E+10
1. 9891E+11
1. 4026E+11
5. 5759E+08
2. 5159E+09
3. 5451E+10 2 5131E+09
3. 5648E+09 3.3358E+09 3 5776E+09
4. 5139E+10
4. 0558E+10 3 -7379E+10 1 7271E+10
1. 3938E+10
2. 3592E+10
5. 1119E+10 24.0000 Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-36 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 2.8524E+00 1.3868E+00 1.8672E-01 3.2842E+00 6.2083E-01 1.7963E+00

1. 8389E+01 1.2742E+02 9.4740E+01
2. 1980E+02
4. 0474E+01
1. 5060E+02
6. 4858E+05 1.7124E+05
1. 5707E+01
5. 2168E+00
9. 9988E+00 3.1304E+00
9. 3230E+00 3.2697E-01
5. 7543E-02
3. 0763E-02 2.2239E-01
1. 9506E-01 1.8318E-01 8.0353E-02 3.5222E-02 2.5530E+00 5.4180E-04
5. 9127E-05 7.8806E-05 2.2706E-02
1. 1376E-05 2.6388E-03 1.3850E-04
5. 0723E-10
5. 2547E-10 1.9795E-08 1.5682E-10 2.0608E-08 2.2526E-09 6. 0571E-08 1.0278E-06 9.1783E-09 1.9403E-07 1.5172E-09 4.2885E-08 3.4650E-03 6.7053E-05 1.2140E-05
7. 1180E-08
1. 1495E-04 1.9138E-10 1.2735E-07 5.8826E-10
1. 0175E-11 2. 1490E-12
7. 8049E-09
2. 9372E-10 5.7431E-08
1. 1933E-09
4. 3538E-10
1. 1005E-08 3.1648E-08 9.5126E-07 3.4584E-07 2.2042E-07 3.3145E-09 7.9619E-10
1. 7119E-09 2.3679E+15
2. 4917E+15 9.3864E+16 7.3208E+14 9.6207E+16 1.0355E+16 2.7634E+17 4.7248E+18 4.1874E+16 8.7855E+17
6. 8185E+15 1.9130E+17 1.5689E+22
2. 9912E+20
5. 4560E+19 3.1519E+17 5.0530E+20 8.2915E+14 5.4779E+17 2.5304E+15
4. 3457E+13
9. 1137E+12
3. 3335E+16 1.2369E+15 2.4018E+17
5. 0252E+15 1.7836E+15 2.7729E+16 8.0079E+16 2.3969E+18 8.6780E+17 5.5078E+17 8.2822E+15
1. 9813E+15 4.2252E+15 Environment Transport Group Inventory:

Time (h)

=

Noble gases Elemental I 24.0000 (atoms)

(atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 1.0238E+23 2.4188E+18 7.4807E+16 1.3440E-04 Release Rate/s

1. 1850E+18
2. 7995E+13
8. 6583E+11 1.5556E-09 Total Release 1.0238E+23 2.4188E+18 7.4807E+16 1.3440E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

24.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 2.3946E+20 7.4059E+18 1.3306E-02 Environment to BNP Control Room - Normal Transport Group Inventory:

Pathway 1.0554E+1I

5. 1310E+10 6.9085E+09 1.2151E+lI 2.2971E+10
6. 6462E+10 6.8039E+11 4.7146E+12 3.5054E+12 8.1325E+12 1.4975E+12 5.5724E+12 2.3998E+16 6.3357E+15 5.8117E+11 1.9302E+1I
3. 6996E+II
1. 1582E+11 3.4495E+lI 1.2098E+10 2.1291E+09
1. 1382E+09 8.2284E+09 7.2171E+09 6.7775E+09
2. 9731E+09 1.3032E+09 9.4461E+10 2.0047E+07 2.1877E+06
2. 9158E+06 8.4011E+08 4.2090E+05 9.7635E+07
5. 1245E+06

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-37 Time (h)

=

24.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Filter o.OOOOE+00 0.OOOOE+00 o.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

24.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

24.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

BNP EAB Doses:

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 A

Time (h)

=

48.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.4544E-02 2.1542E-01 Thyroid 3.8803E-02 7.8953E-01 TEDE 1.5735E-02 2.5601E-01 BNP LPZ Doses:

Time (h)

=

48.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.9649E-03 8.5892E-02 Thyroid 7.9102E-03 3.0686E-01 TEDE 3.2076E-03

1. 0169E-01 BNP CR Doses:

Time (h)

=

48.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3629E-25 1.0583E-24 Thyroid 1.2528E-23 1.4004E-22 TEDE 8.8503E-25 8.9174E-24 BNP CR - Unprotected Dose Doses:

Time (h)

=

48.0000 Whole Body Delta dose (rem) 1.4504E-03 Accumulated dose (rem) 6.5531E-01 Thyroid 5.8885E-03 3.2788E+00 TEDE

1. 6311E-03 8.3198E-01 Environment Integral Nuclide Release:

Time (h)

=

48.0000 Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Ci 3. 7616E-03 4.5067E-03 8.6463E+03 2. 1377E+04 7.4988E+03 3.3318E+04 kg

1. 1830E-10
3. 9869E-09
2. 2038E-02
2. 5976E-06
2. 6474E-07 2.6571E-06 Atoms 1.2283E+15 4.0016E+16 1.5614E+23 1.8403E+19 1.8325E+18
1. 8183E+19 Bq 1.3918E+08 1.6675E+08 3.1991E+14
7. 9094E+14
2. 7745E+14 1.2328E+15

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-38 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 1.7195E-01 5.1543E+00 5. 7333E-01

5. 3761E+00 3.7907E+00 1.5074E-02 6.8000E-02
9. 5813E-01
6. 7921E-02 9.6348E-02
9. 0158E-02
9. 6695E-02
1. 2200E+00
1. 0962E+00
1. 0103E+00
4. 6679E-01 3.7673E-01
6. 3763E-01
1. 3816E+00
2. 8524E+00
1. 3868E+00
1. 8672E-01
3. 2842E+00
6. 2085E-01 1.7963E+00 1.8389E+01 1.6556E+02 9.4755E+01 2.4692E+02
4. 0474E+01 1.5294E+02 1.1268E+06 1.9573E+05 1.5708E+01 5.2169E+00 9.9990E+00 3.1304E+00 9.3232E+00 3.2707E-01 5.7543E-02 3.0763E-02 2.2239E-01
1. 9506E-01 1.8318E-01 8.0355E-02 3.5223E-02 2.5530E+00 5.4182E-04 5.9128E-05 7.8808E-05 2.2706E-02 1.1376E-05 2.6389E-03 1.3850E-04
2. 1132E-09
1. 7741E-07
4. 2031E-06 1.4831E-09
3. 0158E-10
2. 7707E-11 2.7728E-09 9. 9573E-11 2.0358E-11 4.4849E-09 4.7162E-11 2.4728E-09 2.5437E-09
2. 0847E-10 3.1303E-08 6.9443E-11 1.1260E-07
7. 5544E-10
5. 1736E-09 5.0723E-10
5. 2548E-10 1.9795E-08 1.5682E-10 2.0609E-08 2.2527E-09 6.0572E-08 1.3354E-06
9. 1797E-09 2.1798E-07
1. 5172E-09 4.3548E-08 6.0200E-03 7.6647E-05
1. 2140E-05 7.1181E-08 1.1496E-04 1.9138E-10 1.2735E-07 5.8843E-10
1. 0175E-11 2.1490E-12
7. 8051E-09
2. 9373E-10
5. 7433E-08
1. 1933E-09
4. 3539E-10
1. 1005E-08
3. 1649E-08
9. 5128E-07 3.4585E-07
2. 2042E-07
3. 3145E-09 7.9621E-10 1.7120E-09 1.4798E+16 1.2005E+18
2. 8124E+19 9.8145E+15 1.9741E+15 1.8540E+14 1.8350E+16 6.5179E+14 1.3183E+14 2.8430E+16 2.9280E+14
1. 5675E+16
1. 5473E+16
1. 2681E+15
1. 8302E+17
3. 9828E+14 6.3973E+17
4. 3327E+15 2.4533E+16 2.3679E+15 2.4917E+15
9. 3866E+16 7.3209E+14 9.6209E+16 1.0356E+16 2.7634E+17
6. 1390E+18
4. 1880E+16 9. 8698E+17 6.8185E+15 1.9426E+17 2.7258E+22 3.4191E+20 5.4561E+19
3. 1519E+17 5.0531E+20 8.2915E+14 5.4781E+17 2.5312E+15 4.3457E+13 9.1137E+12 3.3336E+16
1. 2370E+15 2.4019E+17 5.0253E+15 1.7837E+15 2.7729E+16 8.0081E+16 2.3970E+18 8.6782E+17 5.5079E+17 8.2824E+15
1. 9814E+15 4.2253E+15 Environment Transport Group Inventory:

6.3620E+09 1.9071E+11 2.1213E+10 1.9892E+11 1.4026E+11 5.5776E+08

2. 5160E+09
3. 5451E+10
2. 5131E+09 3.5649E+09 3.3358E+09 3.5777E+09
4. 5140E+10
4. 0559E+10 3.7380E+10 1.7271E+10 1.3939E+10 2.3592E+10
5. 1120E+10
1. 0554E+11
5. 1312E+10 6.9087E+09 1.2151E+11 2.2971E+10
6. 6463E+10 6.8040E+11
6. 1256E+12 3.5059E+12 9.1362E+12 1.4975E+12
5. 6586E+12
4. 1693E+16
7. 2422E+15
5. 8118E+11
1. 9303E+11
3. 6996E+11
1. 1582E+11 3.4496E+11
1. 2101E+10 2.1291E+09 1.1382E+09 8.2286E+09 7.2172E+09 6.7777E+09 2.9731E+09 1.3032E+09
9. 4463E+10 2.0047E+07
2. 1877E+06
2. 9159E+06
8. 4013E+08 4.2092E+05 9.7638E+07
5. 1246E+06

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-39 Time (h)

=

48.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 1.8826E+23 4.4370E+18 1.3723E+17 1.3441E-04 Release Rate/s

1. 0895E+18 2.5677E+13 7.9413E+11 7.7782E-10 Total Release 1.8826E+23 4.4370E+18 1.3723E+17 1.3441E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

48.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 4.3926E+20 1.3585E+19 1.3306E-02 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

48.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

48.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

48.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

=

72.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 9.5060E-03 2.2493E-01 Thyroid 3.3448E-02 8.2298E-01 TEDE 1.0528E-02 2.6654E-01 BNP LPZ Doses:

Time (h)

=

72.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.9379E-03 8.7830E-02 Thyroid

6. 8185E-03 3.1368E-01 TEDE
2. 1463E-03
1. 0383E-01 BNP CR Doses:

Calculation No. BNP-RAD-007 Revision I Time (h)

=

72.0000 Whole Body Delta dose (rem) 9.3304E-26 Accumulated dose (rem) 1.1516E-24 BNP CR - Unprotected Dose Doses:

Time (h)

=

72.0000 Whole Body Delta dose (rem) 9.4799E-04 Accumulated dose (rem) 6.5626E-01 Attachment No. 91 Thyroid 1.8808E-24 1.4192E-22 Thyroid 5.0758E-03 3.2838E+00 Page 91-40 TEDE 2.0884E-25

9. 1263E-24 TEDE 1.1031E-03 8.3309E-01 Environment Integral Nuclide Release:

Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 72.0000 Ci 3.7616E-03 4.5067E-03 1.2575E+04 2.1388E+04 7.4988E+03 3.3318E+04 1.7195E-01 5.1544E+00

5. 7333E-01
5. 3761E+00 3.7907E+00 1.5079E-02
6. 8001E-02
9. 5813E-01 6.7921E-02 9.6350E-02
9. 0158E-02 9.6697E-02 1.2200E+00 1.0962E+00
1. 0103E+00 4.6679E-01 3.7673E-01 6.3763E-01 1.3816E+00 2.8524E+00 1.3868E+00
1. 8672E-01 3.2842E+00 6.2086E-01
1. 7963E+00
1. 8389E+01
2. 0042E+02
9. 4755E+01 2.5907E+02
4. 0474E+01
1. 5312E+02
1. 5446E+06
1. 9969E+05
1. 5708E+01 5.2170E+00 9.9992E+00
3. 1304E+00 9.3234E+00 kg 1.1830E-10 3.9869E-09 3.2052E-02 2.5989E-06 2.6474E-07 2.6571E-06
2. 1132E-09 1.7742E-07 4.2031E-06 1.4831E-09
3. 0158E-10 2.7715E-11 2.7729E-09
9. 9573E-11 2.0358E-11 4.4850E-09 4.7162E-11 2.4729E-09 2.5437E-09
2. 0847E-10 3.1303E-08
6. 9443E-11 1.1261E-07
7. 5544E-10 5.1737E-09
5. 0723E-10 5.2549E-10 1.9796E-08
1. 5682E-10 2.0609E-08 2.2527E-09 6.0573E-08 1.6166E-06
9. 1798E-09
2. 2870E-07
1. 5172E-09
4. 3602E-08
8. 2518E-03
7. 8197E-05 1.2141E-05
7. 1182E-08
1. 1496E-04 1.9138E-10 1.2735E-07 Atoms 1.2283E+15
4. 0016E+16 2.2709E+23 1.8413E+19 1.8325E+18
1. 8184E+19 1.4798E+16 1.2005E+18 2.8124E+19
9. 8145E+15 1.9741E+15 1.8545E+14 1.8350E+16
6. 5179E+14
1. 3183E+14 2.8431E+16 2.9280E+14 1.5676E+16 1.5473E+16 1.2681E+15 1.8302E+17 3.9828E+14 6.3974E+17 4.3327E+15 2.4533E+16 2.3679E+15 2.4918E+15 9.3868E+16 7.3209E+14
9. 6210E+16 1.0356E+16 2.7635E+17 7.4315E+18 4.1880E+16 1.0355E+18 6.8185E+15 1.9450E+17 3.7364E+22 3.4883E+20 5.4562E+19
3. 1520E+17 5.0532E+20 8.2915E+14 5.4781E+17 Bq
1. 3918E+08 1.6675E+08
4. 6528E+14
7. 9135E+14 2.7745E+14 1.2328E+15 6.3620E+09 1.9071E+ll 2.1213E+I0
1. 9892E+l1 1.4026E+11
5. 5791E+08 2.5161E+09 3.5451E+10
2. 5131E+09 3.5649E+09 3.3358E+09 3.5778E+09 4.5140E+10 4.0559E+10 3.7380E+10 1.7271E+10 1.3939E+10
2. 3592E+10 5.1121E+10 1.0554E+11 5.1312E+10 6.9088E+09 1.2151E+11 2.2972E+10 6.6463E+10
6. 8041E+11
7. 4154E+12
3. 5059E+12
9. 5856E+12
1. 4975E+12 5 6656E+12 5.7150E+16
7. 3887E+15 5.8119E+11
1. 9303E+11
3. 6997E+lI
1. 1582E+11 3.4496E+1I

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-41 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 3.2715E-01 5.7543E-02 3.0763E-02 2.2240E-01

1. 9506E-01 1.8318E-01 8.0356E-02 3.5223E-02 2.5531E+00
5. 4182E-04
5. 9129E-05 7.8809E-05 2.2707E-02
1. 1376E-05 2.6389E-03 1.3851E-04 5.8858E-10 1.0175E-11
2. 1490E-12 7.8052E-09 2.9373E-10 5.7434E-08
1. 1933E-09 4.3540E-10
1. 1005E-08
3. 1649E-08 9.5129E-07 3.4586E-07 2.2043E-07 3.3146E-09 7.9622E-10 1.7120E-09
2. 5318E+15
4. 3457E+13
9. 1137E+12 3.3336E+16 1.2370E+15 2.4019E+17 5.0254E+15 1.7837E+15 2.7730E+16 8. 0082E+16 2.3970E+18
8. 6784E+17 5.5080E+17 8.2826E+15
1. 9814E+15 4.2254E+15 Environment Transport Group Inventory:

Time (h)

=

Noble gases Elemental I 72.0000 (atoms)

(atoms)

Organic I (atoms)

Aerosols (kg)

A Present Release 2.7383E+23 6.4479E+18 1.9942E+17 1.3441E-04 Release Rate/s

1. 0565E+18 2.4876E+13 7.6936E+11 5.1855E-10 Total Release 2.7383E+23 6.4479E+18 1.9942E+17
1. 3441E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

72.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 6.3834E+20 1.9742E+19 1.3306E-02 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

72.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

=

72.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Pathway Time (h)

=

72.0000 Filter

1. 2105E+10
2. 1291E+09
1. 1382E+09 8.2287E+09 7.2172E+09 6.7778E+09 2.9732E+09 1.3033E+09 9.4463E+10 2.0047E+07 2.187BE+06 2. 9160E+06
8. 4015E+08 4.2092E+05
9. 7639E+07
5. 1247E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-42 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg) o.OOOOE+00 o.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

= 96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 7.8119E-03 2.3274E-01 Thyroid 2.9689E-02

8. 5267E-01 TEDE 8.7175E-03 2.7526E-01 BNP LPZ Doses:

Time (h)

=

96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.5925E-03 8.9423E-02 Thyroid 6.0524E-03 3.1973E-01 TEDE 1-7771E-03 1.0561E-01 BNP CR Doses:

Time (h)

=

96.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 7.9877E-26 1.2315E-24 Thyroid 3.9563E-25 1.4231E-22 TEDE

1. 0120E-25 9.2275E-24 BNP CR - Unprotected Dose Doses:

Time (h)

=

96.0000 Whole Body Delta dose (rem) 7.7903E-04 Accumulated dose (rem) 6.5704E-01 Thyroid 4.5055E-03 3.2884E+00 TEDE 9.1647E-04

8. 3400E-01 Environment Integral Nuclide Release:

=

96.0000 Ci

3. 7617E-03
4. 5068E-03
1. 6489E+04
2. 1388E+04
7. 4988E+03
3. 3318E+04 1.7195E-01
5. 1544E+00
5. 7334E-01
5. 3761E+00
3. 7907E+00
1. 5084E-02
6. 8003E-02
9. 5813E-01
6. 7921E-02
9. 6351E-02
9. 0158E-02
9. 6698E-02
1. 2200E+00
1. 0962E+00
1. 0103E+00
4. 6679E-01 3.7674E-01 6 3763E-01 1.3817E+00 kg 1.1830E-10 3.9870E-09 4.2028E-02 2.5990E-06 2.6474E-07 2.6571E-06 2.1132E-09 1.7742E-07 4.2032E-06 1.4831E-09
3. 0158E-10 2.7724E-11 2.7729E-09
9. 9573E-11 2.0358E-11 4.4850E-09 4.7162E-11 2.4729E-09 2.5437E-09
2. 0847E-10 3.1304E-08
6. 9443E-11
1. 1261E-07 7.5544E-10
5. 1737E-09 Atoms 1.2283E+15
4. 0017E+16 2.9777E+23 1.8413E+19 1.8325E+18 1.8184E+19 1.4798E+16 1.2005E+18 2.8125E+19
9. 8145E+15
1. 9741E+15 1.8551E+14 1.8350E+16
6. 5179E+14 1.3183E+14 2.8431E+16 2.9280E+14 1.5676E+16 1.5473E+16 1.2681E+15 1.8302E+17
3. 9828E+14 6.3975E+17 4.3327E+15 2.4533E+16 Bq 1.3918E+08 1.6675E+08
6. 1010E+14
7. 9136E+14 2.7745E+14 1.2328E+15 6.3621E+09 1.9071E+11
2. 1214E+10
1. 9892E+11
1. 4026E+11
5. 5810E+08 2.5161E+09 3.5451E+10 2.5131E+09
3. 5650E+09
3. 3358E+09 3 5778E+09
4. 5140E+10
4. 0559E+10 3.7381E+10 1.7271E+10
1. 3939E+10 2.3592E+10 5.1121E+10 Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-43 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 2.8524E+00 1.3868E+00 1.8673E-01 3.2842E+00 6.2087E-01 1.7963E+00

1. 8390E+01 2.3228E+02 9.4755E+01
2. 6451E+02
4. 0474E+01 1.5314E+02 1.9094E+06 2.0033E+05
1. 5708E+01 5.2171E+00 9.9993E+00 3.1304E+00 9.3235E+00 3.2725E-01 5.7543E-02 3.0763E-02
2. 2240E-01
1. 9506E-01 1.8319E-01 8.0358E-02 3.5224E-02
2. 5531E+00 5.4183E-04 5.9130E-05 7.8811E-05 2.2707E-02 1.1376E-05 2.6389E-03 1.3851E-04
5. 0723E-10
5. 2549E-10
1. 9796E-08
1. 5682E-10
2. 0609E-08
2. 2527E-09
6. 0573E-08
1. 8736E-06
9. 1798E-09 2.3350E-07
1. 5172E-09 4.3606E-08 1.0201E-02 7.8447E-05 1.2141E-05
7. 1183E-08 1.1496E-04
1. 9138E-10 1.2735E-07 5.8875E-10 1.0175E-11
2. 1490E-12 7.8053E-09 2.9373E-10 5.7434E-08
1. 1933E-09
4. 3541E-10
1. 1005E-08
3. 1650E-08
9. 5131E-07 3.4586E-07 2.2043E-07 3.3146E-09 7.9623E-10 1.7120E-09 2.3679E+15 2.4918E+15 9.3869E+16 7.3209E+14
9. 6212E+16
1. 0356E+16 2.7635E+17
8. 6130E+18 4.1880E+16
1. 0573E+18
6. 8185E+15
1. 9452E+17
4. 6188E+22 3.4994E+20 5.4562E+19
3. 1520E+17
5. 0532E+20
8. 2915E+14
5. 4782E+17
2. 5325E+15 4.3457E+13
9. 1137E+12 3.3337E+16 1.2370E+15 2.4019E+17
5. 0255E+15 1.7837E+15 2.7730E+16
8. 0083E+16
2. 3970E+18
8. 6785E+17
5. 5081E+17 8.2827E+15 1.9814E+15 4.2255E+15 Environment Transport Group Inventory:

Time (h)

=

96.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 3.5909E+23 8.4514E+18 2.6138E+17 1.3441E-04 Release Rate/s 1.0390E+18 2.4454E+13 7.5632E+11 3.8892E-10 Total Release 3.5909E+23 8.4514E+18 2.6138E+17 1.3441E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

=

96.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 8.3669E+20 2.5877E+19 1.3307E-02 Environment to BNP Control Room -

Normal Transport Group Inventory:

Pathway

1. 0554E+11
5. 1313E+10
6. 9089E+09 1.2151E+11 2.2972E+10
6. 6463E+10
6. 8041E+II
8. 5943E+12 3.5059E+12
9. 7869E+12 1.4975E+12 5.6661E+12 7.0648E+16 7.4122E+15
5. 8120E+11 1.9303E+11
3. 6997E+11 1.1582E+11 3.4497E+11 1.2108E+10
2. 1291E+09
1. 1382E+09 8.2288E+09 7.2172E+09 6.7779E+09 2.9732E+09 1.3033E+09 9.4464E+10 2.0048E+07 2.1878E+06
2. 9160E+06 8.4016E+08 4.2093E+05 9.7641E+07
5. 1248E+06

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-44 Time (h)

= 96.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.000OE+00 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

=

96.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

=

96.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

BNP EAB Doses:

A Time (h)

= 120.0000 Delta dose (rem)

Accumulated dose (rem)

Pathway Filter 0.000OE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Whole Body 6.7427E-03 2.3948E-01 Thyroid 2.6744E-02 8.7941E-01 TEDE 7.5577E-03 2.8282E-01 BNP LPZ Doses:

Time (h)

= 120.0000 Delta dose (rem)

Accumulated dose (rem)

BNP CR Doses:

Time (h)

= 120.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 5.7025E-04 8.9993E-02 Whole Body 4.7122E-26 1.2786E-24 Thyroid 2.2618E-03 3.2199E-01 Thyroid 7.7400E-26 1.4239E-22 TEDE 6.3918E-04 1.0625E-01 TEDE 5.0464E-26 9.2779E-24 BNP CR - Unprotected Dose Doses:

Time (h)

= 120.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.4414E-04 6.5718E-01 Thyroid 8.7000E-04 3.2892E+00 TEDE 1.7066E-04 8.3418E-01 Environment Integral Nuclide Release:

Time (h)

= 120.0000 Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Ci

3. 7617E-03 4.5069E-03 2.0388E+04 2.1388E+04 7.4988E+03 3.3318E+04 kg
1. 1830E-10 3.9870E-09
5. 1966E-02 2.5990E-06 2.6474E-07 2.6571E-06 Atoms 1.2283E+15 4.0017E+16 3.6817E+23
1. 8413E+19 1.8325E+18
1. 8184E+19 Bq 1.3918E+08 1.6675E+08 7.5436E+14 7.9136E+14 2.7745E+14 1.2328E+15

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-45 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 1.7195E-01

5. 1545E+00 5.7335E-01
5. 3761E+00 3.7907E+00 1.5090E-02 6.8004E-02 9.5813E-01 6.7921E-02 9.6353E-02
9. 0158E-02 9.6699E-02 1.2200E+00 1.0962E+00 1.0103E+00 4.6679E-01 3.7674E-01 6.3764E-01 1.3817E+00 2.8524E+00 1.3868E+00
1. 8673E-01 3.2842E+00 6.2088E-01 1.7963E+00 1.8390E+01 2.6140E+02 9.4755E+01
2. 6695E+02
4. 0474E+01
1. 5314E+02 2.2279E+06 2.0043E+05
1. 5708E+01 5.2171E+00
9. 9994E+00
3. 1304E+00 9.3236E+00
3. 2735E-01 5.7543E-02 3.0763E-02 2.2240E-01
1. 9506E-01 1.8319E-01 8.0359E-02 3.5224E-02 2.5531E+00 5.4184E-04 5.9131E-05 7.8812E-05 2.2707E-02
1. 1377E-05 2.6390E-03 1.3851E-04 2-1133E-09 1.7742E-07 4.2032E-06
1. 4831E-09
3. 0158E-10
2. 7735E-11 2.7730E-09
9. 9573E-11 2.0358E-11
4. 4851E-09
4. 7162E-11 2.4729E-09
2. 5437E-09 2.0847E-10 3.1304E-08 6.9443E-11 1.1261E-07 7.5544E-10 5.1738E-09 5.0723E-10 5.2550E-10 1.9796E-08 1.5682E-10 2. 0610E-08 2.2527E-09 6.0574E-08 2. 1085E-06 9.1798E-09 2.3565E-07 1.5172E-09 4.3606E-08 1.1902E-02 7.8486E-05 1.2141E-05
7. 1184E-08 1.1496E-04 1.9138E-10 1.2736E-07 5.8893E-10 1.0175E-11 2.1490E-12 7.8054E-09 2.9373E-10 5.7435E-08
1. 1934E-09 4.3541E-10 1.1005E-08 3.1650E-08 9.5132E-07 3.4587E-07 2.2043E-07 3.3147E-09 7.9624E-10 1.7121E-09 1.4798E+16 1.2005E+18 2.8125E+19
9. 8145E+15 1.9741E+15 1.8558E+14 1.8351E+16 6.5179E+14 1.3183E+14
2. 8431E+16
2. 9280E+14 1.5676E+16
1. 5474E+16 1.2681E+15 1.8303E+17
3. 9828E+14 6.3976E+17
4. 3327E+15
2. 4533E+16
2. 3679E+15 2.4918E+15 9.3870E+16
7. 3209E+14
9. 6213E+16
1. 0356E+16
2. 7635E+17
9. 6930E+18
4. 1880E+16
1. 0670E+18 6.8185E+15
1. 9452E+17 5.3893E+22 3.5012E+20
5. 4563E+19 3.1520E+17 5.0533E+20 8.2915E+14 5.4783E+17 2.5333E+15 4.3457E+13 9.1137E+12 3.3337E+16 1.2370E+15 2.4020E+17
5. 0255E+15 1.7837E+15 2.7730E+16
8. 0085E+16 2.3971E+18
8. 6786E+17
5. 5082E+17
8. 2828E+15 1.9814E+15 4.2255E+15 Environment Transport Group Inventory:

6.3622E+09

1. 9072E+11
2. 1214E+10
1. 9892E+11 1.4026E+11
5. 5831E+08
2. 5161E+09 3.5451E+10
2. 5131E+09 3.5650E+09 3.3358E+09 3.5779E+09
4. 5141E+10 4.0560E+10 3.7381E+10 1.7271E+10 1.3939E+10 2.3593E+10
5. 1122E+10 1.0554E+11 5.1313E+10 6.9090E+09 1.2152E+11 2.2972E+10 6.6463E+10 6.8042E+11
9. 6719E+12 3.5059E+12
9. 8770E+12 1.4975E+12 5.6662E+12 8.2433E+16 7.4160E+15
5. 8121E+11
1. 9303E+11 3.6998E+11 1.1582E+11 3.4497E+11 1.2112E+10 2.1291E+09 1.1382E+09 8.2289E+09 7.2172E+09 6.7780E+09 2 9733E+09
1. 3033E+09 9.4464E+10
2. 0048E+07
2. 1878E+06 2.9160E+06 8.4017E+08
4. 2093E+05
9. 7642E+07
5. 1249E+06

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-46 Time (h)

= 120.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 4.4404E+23 1.0448E+19 3.2312E+17 1.3441E-04 Release Rate/s 1.0279E+18 2.4184E+13 7.4797E+11 3.1114E-10 Total Release 4.4404E+23 1.0448E+19 3.2312E+17 1.3441E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

= 120.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 1.0343E+21 3.1989E+19 1.3307E-02 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

= 120.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

= 120.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

= 120.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter.

0.OOOOE+00 0.000OE+00 0.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

= 240.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.2805E-02 2.6229E-01 Thyroid 1.0179E-01 9.8120E-01 TEDE 2.5905E-02

3. 0872E-01 BNP LPZ Doses:

Time (h)

= 240.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.9287E-03 9.1922E-02 Thyroid 8.6090E-03

3. 3060E-01 TEDE
2. 1908E-03 1.0844E-01 BNP CR Doses:

Calculation No. BNP-RAD-007 Revision 1 Time (h)

= 240.0000 Whole Body Delta dose (rem) 1.6408E-25 Accumulated dose (rem) 1.4427E-24 BNP CR - Unprotected Dose Doses:

Time (h)

= 240.0000 Whole Body Delta dose (rem) 4.8751E-04 Accumulated dose (rem) 6-5767E-01 Attachment No. 91 Thyroid 8.4394E-26 1.4247E-22 Thyroid 3.3114E-03 3.2925E+00 Page 91-47 TEDE 1.6684E-25 9.4448E-24 TEDE 5.8835E-04 8.3476E-01 Environment Integral Nuclide Release:

Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 240.0000 Ci 3.7620E-03 4.5072E-03 3.9661E+04 2.1388E+04 7.4988E+03 3.3318E+04 1.7196E-01

5. 1549E+00 5.7339E-01 5.3761E+00 3.7907E+00 1.5125E-02 6.8009E-02
9. 5813E-01
6. 7921E-02 9.6359E-02
9. 0158E-02
9. 6706E-02
1. 2200E+00
1. 0962E+00
1. 0104E+00
4. 6679E-01
3. 7677E-01
6. 3764E-01
1. 3817E+00
2. 8524E+00 1.3869E+00
1. 8674E-01 3-2842E+00 6.2091E-01 1.7963E+00 1.8390E+01 3.7352E+02 9.4755E+01 2.6889E+02
4. 0474E+01 1.5314E+02 3.3074E+06 2.0045E+05
1. 5709E+01 5.2173E+00 1.OOOOE+01 3.1304E+00 9.3240E+00 kg 1.1831E-10 3.9873E-09 1.0109E-01 2-5990E-06 2.6474E-07 2-6571E-06
2. 1134E-09 1.7743E-07 4.2036E-06 1.4831E-09
3. 0158E-10 2.7800E-II 2.7732E-09
9. 9573E-11 2.0358E-11 4.4854E-09 4.7162E-11 2.4731E-09 2.5438E-09 2.0848E-10 3.1306E-08
6. 9443E-11 1.1262E-07 7.5545E-10
5. 1739E-09 5.0723E-10 5.2551E-10 1.9798E-08 1.5682E-10 2.0611E-08 2.2527E-09 6.0575E-08 3.0128E-06
9. 1798E-09 2.3736E-07
1. 5172E-09 4.3606E-08 1.7669E-02 7-8494E-05 1.2142E-05 7.1187E-08
1. 1497E-04 1.9138E-10 1.2736E-07 Atoms 1.2284E+15 4.0020E+16
7. 1621E+23
1. 8413E+19
1. 8325E+18
1. 8184E+19 1.4799E+16 1.2006E+18 2.8127E+19 9.8145E+15
1. 9741E+15
1. 8602E+14
1. 8352E+16
6. 5179E+14 1.3183E+14 2.8433E+16
2. 9280E+14
1. 5677E+16
1. 5474E+16 1.2682E+15
1. 8304E+17 3.9828E+14 6.3981E+17 4.3328E+15 2.4534E+16 2.3679E+15 2.4919E+15
9. 3877E+16 7.3210E+14 9.6219E+16
1. 0356E+16 2.7635E+17 1.3850E+19 4.1880E+16
1. 0748E+18 6.8185E+15 1.9452E+17 8.0006E+22
3. 5015E+20 5.4567E+19 3.1522E+17 5.0536E+20 8.2915E+14 5.4785E+17 Bq 1.3919E+08 1.6677E+08 1.4675E+15
7. 9136E+14
2. 7745E+14 1.2328E+15 6.3625E+09 1.9073E+ll 2.1216E+10 1.9892E+11 1.4026E+11 5.5963E+08
2. 5163E+09
3. 5451E+10
2. 5131E+09 3.5653E+09 3.3358E+09 3.5781E+09 4.5141E+10
4. 0560E+10 3.7384E+10 1.7271E+10 1.3940E+10 2.3593E+10 5.1123E+10 1.0554E+11
5. 1315E+10 6.9095E+09
1. 2152E+11
2. 2974E+10
6. 6463E+10
6. 8043E+11
1. 3820E+13
3. 5060E+12
9. 9488E+12
1. 4975E+12
5. 6662E+12
1. 2237E+17 7.4167E+15 5.8125E+11 1.9304E+11 3.7000E+11
1. 1582E+11 3.4499E+11

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-48 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 3.2783E-01 5.7543E-02 3.0763E-02 2.2242E-01 1.9506E-01 1.8320E-01 8.0364E-02 3.5226E-02 2.5531E+00

5. 4188E-04
5. 9135E-05 7.8818E-05 2.2709E-02 1.1377E-05 2.6392E-03 1.3852E-04 5.8981E-10 1.0175E-11 2.1490E-12 7.8059E-09
2. 9373E-10 5.7439E-08
1. 1934E-09
4. 3543E-10
1. 1005E-08
3. 1652E-08
9. 5139E-07 3.4589E-07 2.2045E-07 3.3150E-09 7.9630E-10 1.7122E-09
2. 5371E+15
4. 3457E+13 9.1137E+12 3.3339E+16 1.2370E+15 2.4021E+17
5. 0259E+15 1.7838E+15 2.7730E+16
8. 0090E+16
2. 3972E+18
8. 6792E+17 5.5086E+17 8.2835E+15
1. 9816E+15 4.2258E+15 Environment Transport Group Inventory:

Time (h)

= 240.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

A Present Release 8.6416E+23 2.0320E+19 6.2847E+17 1.3442E-04 Release Rate/s

1. 0002E+18 2.3519E+13
7. 2739E+11 1.5558E-10 Total Release
8. 6416E+23 2.0320E+19 6.2847E+17 1.3442E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

= 240.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 2.0117E+21 6.2218E+19 1.3308E-02 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

= 240.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

= 240.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Pathway Time (h)

= 240.0000 Filter 1.2130E+10

2. 1291E+09
1. 1382E+09 8.2294E+09 7.2172E+09 6.7785E+09 2.9735E+09 1.3034E+09 9.4465E+10 2.0050E+07 2.188DE+06 2.9162E+06 8.4023E+08 4.2097E+05 9.7649E+07 5.1252E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-49 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg) 0.OOOOE+00 0.00003E+00 0.OOOOE+00 o.OOOOE+00 BNP EAB Doses:

Time (h)

= 360.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.1581E-02 2.7387E-01 Thyroid 6.4765E-02 1.0460E+00 TEDE 1.3553E-02 3.2228E-01 BNP LPZ Doses:

Time (h)

= 360.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 9.7946E-04 9.2901E-02 Thyroid 5.4774E-03 3.3608E-01 TEDE

1. 1462E-03
1. 0959E-01 BNP CR Doses:

Time (h)

= 360.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 8.7746E-26 1.5304E-24 Thyroid

4. 6919E-26 1.4252E-22 TEDE 8.9174E-26 9.5340E-24 BNP CR - Unprotected Dose Doses:

Time (h)

= 360.0000 Whole Body Delta dose (rem) 2.4758E-04 Accumulated dose (rem) 6.5792E-01 Thyroid 2.1069E-03 3.2946E+00 TEDE

3. 1173E-04 8.3508E-01 Environment Integral Nuclide Release:

= 360.0000 Ci

3. 7622E-03
4. 5075E-03
5. 8569E+04
2. 1388E+04
7. 4988E+03
3. 3318E+04
1. 7197E-01
5. 1552E+00
5. 7343E-01
5. 3761E+00 3.7907E+00
1. 5164E-02
6. 8014E-02
9. 5813E-01
6. 7921E-02 9.6365E-02
9. 0158E-02 9.6713E-02 1.2200E+00 1.0962E+00
1. 0104E+00
4. 6679E-01 3.7680E-01 6.3764E-01 1.3817E+00 kg
1. 1832E-10 3.9876E-09 1.4928E-01 2.5990E-06 2.6474E-07 2.6571E-06
2. 1135E-09 1.7744E-07 4.2038E-06 1.4831E-09 3.0158E-10 2.7872E-11 2.7734E-09
9. 9573E-11 2. 0358E-11 4.4857E-09 4.7162E-11 2.4733E-09 2.5438E-09
2. 0848E-10 3.1308E-08
6. 9443E-11 1.1262E-07 7.5545E-10 5.1739E-09 Atoms 1.2285E+15
4. 0023E+16 1.0577E+24 1.8413E+19 1.8325E+18
1. 8184E+19 1.4799E+16 1.2007E+18 2.8129E+19 9.8145E+15
1. 9741E+15
1. 8650E+14 1.8354E+16 6.5179E+14 1.3183E+14 2.8435E+16 2.9280E+14
1. 5678E+16 1.5474E+16 1.2682E+15 1.8305E+17 3.9828E+14 6.3985E+17
4. 3328E+15 2.4534E+16 Bq 1.3920E+08 1.6678E+08 2.1671E+15 7.9136E+14 2.7745E+14 1.2328E+15 6.3628E+09 1.9074E+II 2.1217E+10 1.9892E+II 1.4026E+II
5. 6106E+08
2. 5165E+09 3.5451E+10
2. 5131E+09 3.5655E+09 3.3358E+09 3.5784E+09 4.5141E+10
4. 0560E+10 3.7386E+10 1.7271E+10 1.3941E+10
2. 3593E+10 5.1123E+10 Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-50 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 T-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 2.8524E+00 1.3869E+00 1.8676E-01 3.2843E+00 6.2095E-01 1.7963E+00 1.8390E+01 4.4505E+02 9.4756E+01 2.6892E+02

4. 0474E+01
1. 5314E+02 3.8548E+06 2.0045E+05 1.5710E+01 5.2175E+00 1.0001E+01 3.1304E+00 9.3244E+00 3.2822E-01 5.7543E-02 3.0763E-02 2.2243E-01 1.9506E-01 1.8321E-01 8.0368E-02 3-5227E-02 2.5531E+00
5. 4192E-04 5.9139E-05 7.8823E-05 2.2711E-02 1.1378E-05 2.6393E-03 1.3853E-04 5.0723E-10 5.2552E-10 1.9799E-08 1.5682E-10
2. 0612E-08 2.2527E-09 6.0575E-08 3.5899E-06
9. 1798E-09 2.3739E-07 1.5172E-09 4.3606E-08 2.0594E-02 7.8494E-05
1. 2143E-05
7. 1189E-08 1.1497E-04 1.9138E-10 1.2737E-07 5.9050E-10 1.0175E-11 2.1490E-12 7.8063E-09 2.9373E-10 5.7443E-08 1.1935E-09 4.3544E-10 1.1005E-08 3.1655E-08
9. 5146E-07 3-4592E-07 2.2046E-07 3.3152E-09
7. 9635E-10 1.7123E-09 2.3679E+15 2.4919E+15 9.3884E+16 7.3211E+14
9. 6224E+16
1. 0356E+16 2.7636E+17 1.6503E+19 4.1880E+16
1. 0749E+18
6. 8185E+15
1. 9452E+17 9.3248E+22 3.5015E+20 5.4570E+19 3.1523E+17 5.0540E+20 8.2915E+14 5.4787E+17 2.5400E+15 4.3457E+13
9. 1137E+12 3.3341E+16 1.2370E+15 2.4023E+17
5. 0261E+15 1.7839E+15
2. 7730E+16
8. 0096E+16
2. 3974E+18
8. 6798E+17
5. 5090E+17
8. 2841E+15
1. 9817E+15 4.2261E+15 Environment Transport Group Inventory:

Time (h)

= 360.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 1.2767E+24 3.0015E+19 9.2829E+17 1.3443E-04 Release Rate/s

9. 8510E+17 2.3160E+13
7. 1628E+11
1. 0373E-10 Total Release 1.2767E+24
3. 0015E+19 9.2829E+17 1.3443E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

= 360.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.0000E+00 2.9715E+21 9.1901E+19 1.3309E-02 Environment to BNP Control Room -

Normal Transport Group Inventory:

Pathway

1. 0554E+11
5. 1315E+10 6.9099E+09 1.2152E+11 2.2975E+10
6. 6463E+I10 6.8043E+11
1. 6467E+13
3. 5060E+12
9. 9501E+12 1.4975E+12 5.6662E+12 1.4263E+17 7.4167E+15 5.8128E+11 1.9305E+11 3. 7003E+11 1.1582E+11 3.4500E+11 1.2144E+10 2.1291E+09 1.1382E+09 8.2299E+09 7.2172E+09 6.7789E+09 2.9736E+09 1.3034E+09 9.4465E+10 2.0051E+07
2. 1882E+06
2. 9165E+06 8.4029E+08 4.2100E+05 9.7656E+07
5. 1256E+06

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-51 Time (h)

= 360.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

= 360.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.000OE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

= 360.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

BNP EAB Doses:

Time (h)

= 480.0000 Delta dose (rem)

Accumulated dose (rem)

Pathway Filter 0.0000E+00 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Whole Body 5.8897E-03 2.7976E-01 Thyroid

4. 1322E-02 1.0873E+00 TEDE 7.1479E-03 3.2942E-01 BNP LPZ Doses:

Time (h)

= 480.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.9811E-04 9.3399E-02 Thyroid 3.4947E-03 3.3957E-01 TEDE 6.0452E-04 1.1019E-01 BNP CR Doses:

Time (h)

= 480.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 4.6906E-26 1.5773E-24 Thyroid 2.9935E-26 1.4255E-22 TEDE 4.7818E-26 9.5818E-24 BNP CR - Unprotected Dose Doses:

Time (h)

= 480.0000 Whole Body Delta dose (rem) 1.2591E-04 Accumulated dose (rem) 6.5804E-01 Thyroid 1.3442E-03 3.2960E+00 TEDE 1.6684E-04 8.3524E-01 Environment Integral Nuclide Release:

Time (h)

= 480.0000 Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Ci 3.7624E-03 4.5078E-03 7.7119E+04

2. 1388E+04 7.4988E+03 3.3318E+04 kg
1. 1832E-10 3.9879E-09
1. 9656E-01 2.5990E-06 2.6474E-07
2. 6571E-06 Atoms 1.2286E+15
4. 0026E+16 1.3926E+24
1. 8413E+19 1.8325E+18
1. 8184E+19 Bq 1.3921E+08 1.6679E+08 2.8534E+15 7.9136E+14 2.7745E+14 1.2328E+15

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-52 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 1.7197E-01

5. 1554E+00 5.7347E-01
5. 3761E+00 3.7907E+00 1.5203E-02
6. 8019E-02 9.5813E-01 6.7921E-02 9.6370E-02
9. 0158E-02
9. 6719E-02 1.2200E+00 1.0962E+00
1. 0105E+00
4. 6679E-01
3. 7682E-01 6.3764E-01 1.3817E+00 2.8524E+00 1.3869E+00 1.8677E-01 3.2843E+00 6.2098E-01 1.7963E+00
1. 8390E+01 4.9070E+02 9.4756E+01 2.6892E+02
4. 0474E+01
1. 5314E+02 4.1324E+06 2.0045E+05
1. 5711E+01 5.2177E+00
1. 0001E+01
3. 1304E+00 9.3246E+00 3.2850E-01 5.7543E-02 3.0763E-02 2.2244E-01 1.9506E-01 1.8323E-01
8. 0371E-02 3.5228E-02
2. 5531E+00 5.4195E-04 5.9144E-05 7.8828E-05 2.2712E-02 1.1379E-05 2.6395E-03 1.3854E-04 2.1135E-09 1.7745E-07 4.2041E-06 1.4831E-09
3. 0158E-10 2.7943E-11 2.7736E-09 9.9573E-11
2. 0358E-11 4.4859E-09
4. 7162E-11 2.4734E-09 2.5438E-09 2.0848E-10
3. 1309E-08 6.9443E-11
1. 1263E-07
7. 5545E-10
5. 1739E-09
5. 0723E-10 5.2553E-10 1.9800E-08 1.5683E-10 2. 0613E-08 2.2527E-09 6.0575E-08 3.9580E-06 9.1798E-09 2.3739E-07
1. 5172E-09 4.3606E-08 2.2077E-02 7.8494E-05
1. 2143E-05
7. 1191E-08
1. 1498E-04 1.9138E-10 1.2737E-07
5. 9101E-10 1.0175E-11 2.1490E-12 7.8067E-09 2.9373E-10 5.7447E-08 1.1935E-09
4. 3545E-10 1.1005E-08
3. 1657E-08 9.5153E-07 3.4594E-07 2.2048E-07 3.3155E-09
7. 9640E-10 1.7124E-09 1.4800E+16 1.2007E+18
2. 8131E+19
9. 8145E+15 1.9741E+15 1.8697E+14 1.8355E+16
6. 5179E+14 1.3183E+14 2.8437E+16 2.9280E+14 1.5679E+16 1.5474E+16 1.2682E+15 1.8306E+17 3.9828E+14 6.3989E+17
4. 3328E+15
2. 4534E+16
2. 3679E+15 2.4920E+15
9. 3890E+16
7. 3211E+14
9. 6229E+16
1. 0356E+16
2. 7636E+17
1. 8195E+19
4. 1880E+16
1. 0749E+18
6. 8185E+15
1. 9452E+17 9.9964E+22
3. 5015E+20
5. 4573E+19
3. 1524E+17
5. 0543E+20
8. 2915E+14 5.4789E+17
2. 5423E+15 4.3457E+13
9. 1137E+12 3.3343E+16 1.2370E+15 2.4025E+17
5. 0263E+15 1.7839E+15
2. 7730E+16 8.0102E+16 2.3976E+18
8. 6804E+17
5. 5094E+17 8.2847E+15 1.9818E+15 4.2264E+15 Environment Transport Group Inventory:

6.3630E+09

1. 9075E+11
2. 1219E+10
1. 9892E+11 1.4026E+11 5.6250E+08
2. 5167E+09
3. 5451E+10
2. 5131E+09 3.5657E+09 3.3358E+09 3.5786E+09
4. 5141E+10
4. 0560E+10 3.7388E+10 1.7271E+10 1.3942E+10
2. 3593E+10
5. 1123E+10 1.0554E+11
5. 1316E+10 6.9104E+09
1. 2152E+11 2.2976E+10 6.6463E+10 6.8043E+11
1. 8156E+13 3.5060E+12 9.9501E+12 1.4975E+12
5. 6662E+12 1.5290E+17 7.4167E+15
5. 8132E+11 1.9305E+11 3.7005E+11 1.1582E+11 3.4501E+11 1.2155E+10
2. 1291E+09 1.1382E+09 8.2303E+09 7.2172E+09 6.7794E+09 2.9737E+09 1.3034E+09 9.4465E+10 2.0052E+07
2. 1883E+06
2. 9167E+06 8.4035E+08 4.2103E+05 9.7662E+07
5. 1260E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-53 Time (h)

= 480.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 1.6818E+24 3.9534E+19 1.2227E+18 1.3444E-04 Release Rate/s 9.7324E+17 2.2878E+13 7.0758E+11 7.7800E-II Total Release

1. 6818E+24
3. 9534E+19 1.2227E+18 1.3444E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

= 480.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 3.9139E+21 1.2105E+20 1.3309E-02 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

= 480.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

= 480.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

= 480.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP EAB Doses:

Time (h)

= 600.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.0023E-03 2.8276E-01 Thyroid 2.6366E-02

1. 1137E+00 TEDE 3.8052E-03 3.3323E-01 BNP LPZ Doses:

Time (h)

= 600.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 2.5391E-04 9.3653E-02 Thyroid 2.2299E-03 3.4180E-01 TEDE 3.2182E-04 1.1051E-01 BNP CR Doses:

Calculation No. BNP-RAD-007 Revision 1 Time (h)

= 600.0000 Whole Body Delta dose (rem) 2.5093E-26 Accumulated dose (rem) 1.6024E-24 BNP CR - Unprotected Dose Doses:

Time (h)

= 600.0000 Whole Body Delta dose (rem) 6.4182E-05 Accumulated dose (rem) 6.5811E-01 Attachment No. 91 Thyroid 1.9101E-26 1.4257E-22 Thyroid 8.5772E-04 3.2968E+00 Page 91-54 TEDE 2.5674E-26 9.6074E-24 TEDE 9.0300E-05 8.3533E-01 Environment Integral Nuclide Release:

Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 600.0000 Ci 3.7626E-03 4.5081E-03 9.5317E+04 2.1388E+04 7.4988E+03 3.3318E+04

1. 7198E-01
5. 1557E+00 5.7351E-01 5.3761E+00 3.7907E+00 1.5241E-02 6.8023E-02
9. 5813E-01 6.7921E-02 9.6375E-02 9.0158E-02 9.6726E-02 1.2200E+00 1.0962E+00 1.0105E+00
4. 6679E-01 3.7684E-01
6. 3764E-01 1.3817E+00 2.8524E+00 1.3869E+00
1. 8678E-01 3.2843E+00 6.2100E-01 1.7963E+00 1.8390E+01
5. 1982E+02 9.4756E+01 2.6892E+02 4.0474E+01
1. 5314E+02 4.2732E+06 2.0045E+05 1.5712E+01 5.2177E+00 1.0002E+01 3.1304E+00 9.3248E+00 kg 1.1833E-10
3. 9881E-09
2. 4295E-01
2. 5990E-06
2. 6474E-07
2. 6571E-06
2. 1136E-09 1.7746E-07 4.2044E-06 1.4831E-09
3. 0158E-10 2.8013E-11 2.7738E-09 9.9573E-11 2.0358E-11 4.4862E-09 4.7162E-11 2.4736E-09 2.5438E-09 2.0848E-10 3.1311E-08 6.9443E-11 1.1264E-07
7. 5545E-10
5. 1739E-09 5.0723E-10 5.2553E-10 1.9801E-08 1.5683E-10 2.0614E-08 2.2527E-09 6.0575E-08
4. 1930E-06 9.1798E-09 2.3739E-07 1.5172E-09 4.3606E-08 2.2829E-02 7.8494E-05 1.2144E-05 7.1192E-08 1.1499E-04 1.9138E-10 1.2737E-07 Atoms 1.2286E+15
4. 0028E+16
1. 7213E+24
1. 8413E+19
1. 8325E+18
1. 8184E+19 1.4800E+16 1.2008E+18
2. 8133E+19
9. 8145E+15
1. 9741E+15
1. 8744E+14
1. 8356E+16
6. 5179E+14 1.3183E+14
2. 8438E+16
2. 9280E+14
1. 5680E+16
1. 5474E+16 1.2682E+15
1. 8307E+17 3.9828E+14 6.3993E+17 4-3328E+15
2. 4534E+16 2.3679E+15 2.4920E+15
9. 3895E+16 7.3212E+14 9.6233E+16 1.0356E+16 2.7636E+17
1. 9275E+19
4. 1880E+16 1.0749E+18 6.8185E+15 1.9452E+17 1.0337E+23 3.5015E+20 5.4577E+19
3. 1524E+17 5.0546E+20 8.2915E+14 5.4790E+17 Bq 1.3922E+08 1.6680E+08 3'.5267E+15 7.9136E+14 2.7745E+14 1.2328E+15 6.3631E+09 1.9076E+11
2. 1220E+10
1. 9892E+11 1.4026E+11
5. 6391E+08
2. 5169E+09
3. 5451E+10 2.5131E+09 3.5659E+09 3.3358E+09 3.5788E+09 4.5141E+10 4.0560E+10 3.7389E+10 1.7271E+10 1.3943E+10 2.3593E+10 5.1123E+10
1. 0554E+11 5.1317E+10
6. 9108E+09 1.2152E+11 2.2977E+10
6. 6463E+10
6. 8043E+11 1.9233E+13
3. 5060E+12 9.9501E+12 1.4975E+12 5.6662E+12 1.5811E+17 7.4167E+15 5.8135E+ll 1.9306E+I1 3.7007E+11 1.1582E+11 3.4502E+11

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-55 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 3.2872E-01 5.7543E-02

3. 0763E-02
2. 2245E-01
1. 9506E-01
1. 8324E-01
8. 0373E-02
3. 5228E-02
2. 5531E+00
5. 4199E-04
5. 9147E-05
7. 8834E-05
2. 2714E-02
1. 1380E-05
2. 6397E-03
1. 3855E-04
5. 9140E-10
1. 0175E-I1 2.1490E-12 7.8070E-09 2.9373E-10 5.7451E-08 1.1936E-09 4.3546E-10
1. 1005E-08 3.1659E-08
9. 5159E-07 3.4596E-07 2.2049E-07 3.3157E-09
7. 9645E-10 1.7125E-09 2.5439E+15
4. 3457E+13
9. 1137E+12 3.3344E+16 1.2370E+15 2.4026E+17
5. 0264E+15 1.7840E+15 2.7730E+16
8. 0107E+16 2.3977E+18
8. 6810E+17
5. 5097E+17
8. 2854E+15
1. 9820E+15 4.2267E+15 Environment Transport Group Inventory:

Time (h)

= 600.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

A Present Release 2.0795E+24 4.8881E+19 1.5118E+18 1.3445E-04 Release Rate/s

9. 6274E+17 2.2630E+13 6.9990E+11 6.2244E-11 Total Release 2.0795E+24 4.8881E+19
1. 5118E+18 1.3445E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

= 600.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 4.8392E+21 1.4967E+20 1.3310E-02 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

= 600.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Environment to BNP Control Room - Normal Transport Group Inventory:

Time (h)

= 600.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Pathway Time (h)

= 600.0000 Filter

1. 2162E+10
2. 1291E+09
1. 1382E+09
8. 2306E+09
7. 2172E+09
6. 7798E+09 2 9738E+09
1. 3034E+09
9. 4465E+10
2. 0054E+07
2. 1885E+06
2. 9168E+06
8. 4040E+08
4. 2107E+05 9.7668E+07 5.1263E+06

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-56 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg) o.OOOOE+00 o.OOOOE+00 o.OOOOE+00 o.OOOOE+00 BNP EAB Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.5373E-03 2.8430E-01 Thyroid 1.6824E-02

1. 1305E+00 TEDE 2.0496E-03 3.3528E-01 BNP LPZ Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3001E-04 9.3783E-02 Thyroid 1.4228E-03 3.4322E-01 TEDE 1.7334E-04 1.1069E-01 BNP CR Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 1.3463E-26 1.6159E-24 Thyroid 1.2188E-26 1.4258E-22 TEDE 1.3834E-26

9. 6213E-24 BNP CR - Unprotected Dose Doses:

Time (h)

= 720.0000 Delta dose (rem)

Accumulated dose (rem)

Whole Body 3.2863E-05 6.5814E-01 Thyroid 5.4729E-04 3.2974E+00 TEDE 4.9529E-05 8.3538E-01 Environment Integral Nuclide Release:

= 720.0000 Ci 3.7628E-03 4.5084E-03

1. 1317E+05
2. 1388E+04 7.4988E+03 3.3318E+04 1.7198E-01
5. 1559E+00 5.7355E-01 5.3761E+00 3.7907E+00 1.5278E-02
6. 8027E-02
9. 5813E-01
6. 7921E-02
9. 6380E-02
9. 0158E-02 9.6731E-02
1. 2200E+00
1. 0962E+00
1. 0106E+00 4.6679E-01 3.7687E-01 6.3764E-01 1.3817E+00 kg
1. 1834E-10 3.9884E-09
2. 8845E-01 2.5990E-06
2. 6474E-07 2.6571E-06
2. 1136E-09 1.7747E-07 4.2047E-06 1.4831E-09
3. 0158E-10 2.8081E-11 2.7739E-09
9. 9573E-11 2.0358E-11 4.4864E-09 4.7162E-11 2.4737E-09 2.5438E-09 2.0848E-10 3.1312E-08
6. 9443E-I1 1.1265E-07 7.5545E-10 5.1739E-09 Atoms 1.2287E+15
4. 0031E+16 2.0437E+24
1. 8413E+19
1. 8325E+18
1. 8184E+19 1.4801E+16 1.2008E+18 2.8135E+19 9.8145E+15
1. 9741E+15 1.8790E+14 1.8357E+16 6.5179E+14 1.3183E+14 2.8439E+16 2.9280E+14 1.5681E+16
1. 5474E+16 1.2682E+15
1. 8307E+17
3. 9828E+14 6.3997E+17 4.3328E+15 2.4534E+16 Bq 1.3922E+08
1. 6681E+08
4. 1873E+15
7. 9136E+14 2.7745E+14 1.2328E+15 6.3633E+09
1. 9077E+11 2.1221E+10 1.9892E+11 1.4026E+11 5.6528E+08
2. 5170E+09 3.5451E+10 2.5131E+09
3. 5661E+09 3.3358E+09 3.5791E+09
4. 5141E+10 4.0560E+10 3.7391E+10 1.7271E+10 1.3944E+10 2.3593E+10 5.1123E+10 Time (h)

Co-58 Co-60 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 Sr-89 Sr-90 Sr-91 Sr-92 Y-90 Y-91 Y-92 Y-93 Zr-95 Zr-97 Nb-95 Mo-99 Tc-99m Ru-103 Ru-105 Ru-106 Rh-105 Sb-127

Calculation No. BNP-RAD-007 Revision I Attachment No. 91 Page 91-57 Sb-129 Te-127 Te-127m Te-129 Te-129m Te-131m Te-132 1-131 1-132 1-133 1-134 1-135 Xe-133 Xe-135 Cs-134 Cs-136 Cs-137 Ba-139 Ba-140 La-140 La-141 La-142 Ce-141 Ce-143 Ce-144 Pr-143 Nd-147 Np-239 Pu-238 Pu-239 Pu-240 Pu-241 Am-241 Cm-242 Cm-244 2.8524E+00 1.3869E+00 1.8679E-01 3.2843E+00 6.2103E-01 1.7963E+00 1.8390E+01

5. 3841E+02 9.4756E+01 2.6892E+02
4. 0474E+01
1. 5314E+02 4.3446E+06 2.0045E+05 1.5713E+01 5.2178E+00
1. 0003E+01
3. 1304E+00 9.3249E+00 3.2887E-01 5.7543E-02 3.0763E-02 2.2246E-01 1.9506E-01 1.8325E-01 8.0374E-02 3.5229E-02 2. 5531E+00 5.4203E-04
5. 9151E-05 7.8839E-05 2.2715E-02 1.1381E-05 2.6398E-03 1.3856E-04
5. 0723E-10 5.2554E-10 1.9803E-08
1. 5683E-10 2.0615E-08 2.2527E-09 6.0575E-08 4.3429E-06
9. 1798E-09 2.3739E-07 1.5172E-09 4.3606E-08 2.3211E-02 7.8494E-05 1.2145E-05 7.1193E-08 1.1500E-04 1.9138E-10 1.2737E-07
5. 9168E-10 1.0175E-11
2. 1490E-12 7.8073E-09 2.9373E-10 5.7454E-08 1.1936E-09 4.3547E-10
1. 1005E-08
3. 1661E-08
9. 5165E-07 3.4599E-07 2.2051E-07 3.3160E-09 7.9650E-10 1.7126E-09 2.3679E+15 2.4920E+15 9.3901E+16 7.3212E+14 9.6237E+16 1.0356E+16 2.7636E+17 1.9964E+19 4.1880E+16
1. 0749E+18
6. 8185E+15
1. 9452E+17 1.0510E+23
3. 5015E+20 5.4580E+19 3.1525E+17 5.0549E+20 8.2915E+14 5.4791E+17 2.5451E+15
4. 3457E+13
9. 1137E+12
3. 3345E+16 1.2370E+15
2. 4028E+17
5. 0265E+15 1.7840E+15 2.7730E+16
8. 0112E+16
2. 3979E+18
8. 6816E+17
5. 5101E+17 8.2861E+15
1. 9821E+15 4.2270E+15 Environment Transport Group Inventory:

Time (h)

= 720.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Present Release 2.4701E+24 5.8059E+19 1.7956E+18 1.3445E-04 Release Rate/s

9. 5296E+17 2.2399E+13
6. 9277E+II 5.1873E-11 Total Release 2.4701E+24
5. 8059E+19 1.7956E+18 1.3445E-04 BNP Drywell to Environment Transport Group Inventory:

Time (h)

= 720.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 5.7479E+21 1.7777E+20 1.3311E-02 Environment to BNP Control Room - Normal Transport Group Inventory:

Pathway

1. 0554E+11
5. 1317E+10
6. 9112E+09 1.2152E+II 2.2978E+10
6. 6463E+10 6.8043E+11 1.9921E+13 3.5060E+12 9.9501E+12 1.4975E+12 5.6662E+12 1.6075E+17 7.4167E+15 5.8139E+11 1.9306E+lI 3.7009E+lI 1.1582E+11 3.4502E+Il 1.2168E+10 2.1291E+09
1. 1382E+09 8.2309E+09
7. 2172E+09 6.7802E+09 2.9739E+09 1.3035E+09 9.4465E+10 2.0055E+07 2.1886E+06
2. 9170E+06 8.4046E+08 4.2110E+05 9.7673E+07
5. 1266E+06

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-58 Time (h)

= 720.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Filter 0.0000E+00 0.OOOOE+00 0.OOOOE+00 o.OOOOE+00 Environment to BNP Control Room -

Normal Transport Group Inventory:

Time (h)

= 720.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg)

Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.0000E+00 BNP Control Room to Environment -

CR Exh Transport Group Inventory:

Time (h)

= 720.0000 Noble gases (atoms)

Elemental I (atoms)

Organic I (atoms)

Aerosols (kg) 838 Pathway Filter 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 OA 1-131 Summary BNP Drywell 1-131 (Curies) 4.4384E+03 3-9938E+05 2.1374E+06 3.4679E+06 7.2092E+06 1.1012E+07 1.4390E+07 1.7454E+07 1.8416E+07 2.0261E+07 1.6643E+07 1.2846E+07 9.9821E+06 7.8208E+06 6.1899E+06 4.9591E+06 4.0303E+06 3.3292E+06 2.8000E+06 2.4003E+06 2.1651E+06 2.0029E+06 1.8668E+06 1.7526E+06 1.6568E+06 Environment 1-131 (Curies) 0.OOOOE+00 0.OOOOE+00 6.3262E-01 1.7090E+00 4.7067E+00 9.9193E+00 1.7171E+01 2.6256E+01 2.9662E+01

3. 7011E+01
4. 7728E+01
5. 6078E+01
6. 2543E+01
6. 7585E+01 7.1555E+01 7.4714E+01 7.7263E+01 7.9350E+01 8.1089E+01 8.2565E+01 8.3856E+01 8.5042E+01 8.6143E+01 8.7174E+01 8.8144E+01 BNP Control Room 1-131 (Curies) 0.OOOOE+00 0.OOOOE+00 2.7761E-29 7.4227E-29 2.0269E-28 4.2421E-28 7.2894E-28 1.1059E-27 1.2461E-27 2.3185E-26 5.4516E-26 5.3364E-26 5.2208E-26 5.1058E-26 4.9917E-26 4.8790E-26 4.7679E-26 4.6588E-26 4.5516E-26 4.4466E-26 4.3438E-26 4.2432E-26 4.1448E-26 4.0487E-26 3.9547E-26 Time (hr) 0.001 0.050 0.300 0.500 0.800 1.100 1.400 1.700 1.800 2.000 2.300 2.600 2.900 3.200 3.500 3.800 4.100 4.400 4.700 5.000 5.300 5.600 5.900 6.200 6.500

Calculation No. BNP-RAD-007 Revision I 6.800 7.100 7.400 7.700 8.000 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 Attachment No. 91

1. 5764E+06
1. 5088E+06 1.4520E+06
1. 4042E+06
1. 3640E+06
1. 3301E+06 1.3035E+06 1.2821E+06 1.2635E+06 1.2474E+06 1.2334E+06 1.2211E+06
1. 2104E+06 1.0953E+06 8.3641E+05 8.0864E+04 Page 91-59
8. 9064E+01
8. 9943E+01
9. 0786E+01 9.1599E+01
9. 2387E+01 9.3154E+01
9. 3904E+01 9.4641E+01 9.5366E+01
9. 6081E+01
9. 6788E+01
9. 7487E+01
9. 8179E+01 1.2742E+02 2.3228E+02 5.3841E+02 Cumulative Dose Summary BNP EAB Thyroid TEDE (rem)

(rem)

0. 0000E-00 O.OOOOE+00 0.OOOOE+00 0-0000E+00 1.2317E-03 1.5271E-04 3.3221E-03 4.1505E-04 9.2209E-03 1.5612E-03 1.9564E-02 3.9468E-03 3.3970E-02 7.4084E-03 5.2000E-02 1.1800E-02 5.8754E-02 1.3448E-02 2.9331E-01 7.0631E-02 6.3448E-01 1.5636E-01 6.5090E-01 1.6113E-01 6.6357E-01 1.6543E-01 6.7340E-01 1.6934E-01 6.8109E-01 1.7291E-01 6.8719E-01 1.7620E-01 6.9208E-01 1.7924E-01 6.9606E-01 1.8206E-01 6.9936E-01 1.8469E-01 7.0214E-01 1.8716E-01 7.0456E-01 1.8947E-01 7.0676E-01 1.9165E-01 7.0880E-01 1.9371E-01 7.1070E-01 1.9565E-01 7.1249E-01 1.9750E-01 7.1417E-01 1.9925E-01 7.1576E-01 2.0091E-01 7.1729E-01 2.0249E-01 7.1876E-01 2.0399E-01 7.2017E-01 2.0543E-01 7.2088E-01 2.0678E-01 7.2157E-01 2.0806E-01 7.2224E-01 2.0929E-01 BNP Thyroid (rem) 0.OOOOE+00 0.OOOOE+00
1. 1876E-03 3.2031E-03 8.8907E-03 1.8863E-02 3.2754E-02
5. 0138E-02 5.6650E-02 1.3203E-01 2.4167E-01
2. 5036E-01 2.5705E-01 2.6225E-01 2.6633E-01 2.6955E-01 2.7214E-01 2.7424E-01 2.7599E-01 2.7746E-01
2. 7873E-01 2.7990E-01 2.8098E-01 2.8199E-01 2.8293E-01 2.8382E-01 2.8466E-01 2.8547E-01 2.8625E-01 2.8700E-01 2.8727E-01 2.8754E-01 2.8780E-01 LPZ TEDE (rem) 0.OOOOE+00 0.OOOOE+00 1.4724E-04
4. 0018E-04 1.5053E-03 3.8054E-03
7. 1431E-03
1. 1377E-02 1.2966E-02
3. 1343E-02 5.8894E-02 6.1417E-02 6.3692E-02 6.5759E-02 6.7649E-02
6. 9388E-02
7. 0995E-02
7. 2489E-02 7.3881E-02
7. 5183E-02
7. 6405E-02 7.7558E-02 7.8647E-02 7.9677E-02 8.0653E-02
8. 1578E-02 8.2457E-02 8.3293E-02 8.4089E-02 8.4848E-02 8.5374E-02 8.5877E-02 8.6358E-02 BNP CR Thyroid TEDE (rem)

(rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 6.4283E-28 2.9810E-29 2.9034E-27 1.3469E-28 1.1916E-26 5.8237E-28 3.3067E-26 1.7536E-27 7.2558E-26 4.0750E-27 1.3573E-25 7.9108E-27 1.6287E-25 9.5810E-27 7.2441E-25 4.6144E-26 3.4611E-24 2.2498E-25 7.1948E-24 4.6866E-25 1.0837E-23 7.0503E-25 1.4387E-23 9.3434E-25 1.7848E-23 1.1568E-24 2.1221E-23 1.3728E-24 2.4507E-23 1.5823E-24 2.7709E-23 1.7858E-24 3.0828E-23 1.9834E-24 3.3866E-23 2.1754E-24 3.6826E-23 2.3619E-24 3.9709E-23 2.5431E-24 4.2518E-23 2.7193E-24 4.5254E-23 2.8906E-24 4.7919E-23 3.0571E-24 5.0515E-23 3.2191E-24 5.3045E-23 3.3768E-24 5.5510E-23 3.5301E-24 5.7911E-23 3.6794E-24 6.0250E-23 3.8246E-24 6.2530E-23 3.9660E-24 6.4750E-23 4.1037E-24 6.6914E-23 4.2377E-24 3.8628E-26 3.7731E-26 3.6854E-26 3.5998E-26 3.5161E-26 3.4339E-26 3.3536E-26 3.2752E-26

3. 1986E-26
3. 1239E-26 3.0509E-26
2. 9796E-26
2. 9100E-26
1. 0039E-26 9.2662E-29 1.2474E-30 Time (hr) 0.001 0.050 0.300 0.500 0.800 1.100 1.400 1.700 1.800 2.000 2.300 2.600 2.900 3.200 3.500 3.800 4.100 4.400 4.700 5.000 5.300 5.600 5.900 6.200 6.500 6.800 7.100 7.400 7.700 8.000 8.300 8.600 8.900

Calculation No. BNP-RAD-007 Revision 1 7.2290E-01 7.2355E-01

7. 2419E-01 7.2482E-01 7.2545E-01 7. 5073E-01
8. 5267E-01
1. 1305E+00 2.1047E-01
2. 1160E-01
2. 1268E-01
2. 1372E-01
2. 1472E-01
2. 4028E-01
2. 7526E-01 3.3528E-01 Attachment No. 91 2.8806E-01 2.8832E-01 2.8857E-01 2.8881E-01 2.8906E-01
2. 9895E-01
3. 1973E-01 3.4322E-01
8. 6819E-02 8.7261E-02 8.7685E-02 8.8092E-02 8.8483E-02 9.8480E-02 1.0561E-01
1. 1069E-01 6.9022E-23 7.1076E-23 7.3077E-23 7.5027E-23 7.6927E-23 1.2751E-22 1.4231E-22 1.4258E-22 Page 91-60 4.3682E-24 4.4953E-24 4.6191E-24 4.7398E-24 4.8573E-24 8.0324E-24 9.2275E-24 9.6213E-24 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 Time (hr) 0.001 0.050 0.300 0.500 0.800 1.100 1.400 1.700 1.800 2.000 2.300 2.600 2.900 3.200 3.500 3.800 4.100 4.400 4.700 5.000 5.300 5.600 5.900 6.200 6.500 6.800 7.100 7.400 7.700 8.000 8.300 8.600 8.900 9.200 9.500 9.800 10.100 10.400 24.000 96.000 720.000 Worst Two-Hour Doses Note: All of the dose locations are shown below but the BNP CR - Unprotected Thyroid TEDE (rem)

(rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 1.5778E-03 1.9562E-04 4.2556E-03 5.3167E-04 1.1812E-02 1.9999E-03 2.5061E-02 5.0558E-03 4.3516E-02 9.4901E-03 6.6612E-02 1.5115E-02 7.5263E-02 1.7227E-02 1.3543E+00 3.2905E-01 3.2147E+00 7.9653E-01 3.2225E+00 7.9880E-01 3.2286E+k0 8.0085E-01 3.2332E+00 8.0271E-01 3.2369E+00 8.0441E-01 3.2398E+00 8.0598E-01 3.2421E+00 8.0743E-01 3.2440E+00 8.0878E-01 3.2456E+00 8.1003E-01 3.2469E+00 8.1120E-01 3.2481E+00 8.1230E-01 3.2491E+00 8.1334E-01 3.2501E+00 8.1432E-01 3.2510E+00 8.1525E-01 3.2519E+00 8.1613E-01 3.2527E+00 8.1697E-01 3.2534E+00 8.1776E-01 3.2542E+00 8.1851E-01 3.2549E+00 8.1923E-01 3.2555E+00 8.1991E-01 3.2559E+00 8.2031E-01 3.2563E+00 8.2069E-01 3.2567E+00 8.2106E-01 3.2571E+00 8.2141E-01 3.2575E+00 8.2174E-01 3.2578E+00 8.2207E-01 3.2582E+00 8.2238E-01 3.2585E+00 8.2267E-01 3.2729E+00 8.3035E-01 3.2884E+00 8.3400E-01 3.2974E+00 8.3538E-01

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 91 Page 91-61 worst two-hour dose is only meaningful for the EAB dose location.

Please disregard the two-hour worst doses for the other dose locations Whole Body (rem) 1.2945E-01 Whole Body (rem) 4.8179E-02 Whole Body (rem) 2.3194E-25 Unprotected Whole Body (rem) 6.2413E-01 Thyroid (rem) 6.4456E-01 Thyroid (rem) 2.4593E-01 Thyroid (rem) 2.3181E-23 Dose Thyroid (rem) 3.2147E+00 TEDE (rem) 1.6431E-01 TEDE (rem) 6.1428E-02 TEDE (rem) 1.4930E-24 TEDE (rem) 7.9817E-01 BNP EAB Time (hr) 1.4 BNP LPZ Time (hr) 0.8 BNP CR Time (hr) 2.3 BNP CR Time (hr) 0.8

CAROLINA POWER & LIGHT COMPANY Calculation No.

BRUNSWICK NUCLEAR PLANT BNP-RAD-007 CALCULATION SHEET Page No.

Rev.

98-1 1

Attachment No. 98 EXCEL Spreadsheet - Post LOCA Activity in the Environment (UFSAR Table)

Calculation No. BNP-RAD-007 Revision 1 Attachment No, 98 Page 98-2 "A

B C

D I

E F

G I

H I

J 1

BNP EPU/AST - LOCA Activity (Curies) in Envirojunent at 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 Isotope PLKG-RB PLKG-ST MSIV-SCB HPCI-SCB 1

RCIC-SCB MSIV-LKG ESF-RB ESF-ST Total 3

Co-58 1.51E-03 3.16E-08 2.61E-12 I

2.87E-12 1,51E-03 4

Co-60 1.81E-03 3.79E-08 3.13E-12 3.43E-12 8.75E-14 1.81E-03 5

Kr-85 2.58E-02 1.65E+02 7.09E-02 2.25E-02 1.57E-02 4.14E-02 1.65E+02 6

Kr-85m 5.06E-01 2.59E+03 1.09E+00 3.42E-01 I

2.40E-01 6.28E-01 2.59E+03 7

Kr-87 9.51E-01 2.81E+03 1.12E+00 3.42E-01 2.43E-01 6.26E-01 2.82E+03 8

Kr-88 1,36E+00 6.14E+03 2.55E+00 7.97E-01 I

5,60R-01 1.46E+00 6.15E+03 9

Rb-86 4.73E-03 7,87E-02 2.10E-06 2.05E-10 2.03E-10 5.99E-12 8.34E-02 10 Sr-89 2.07E+00 4.33E-05 3.58E-09 3.93E-09 LOO.E-10 2.07E+00 11 Sr-90 2.30E-01 4.82E-06 3,98E-10 4.37E-10 1.11E-11 2.30E-01 12 Sr-91 2.32E+00 4.81E-05 3.95E-09 4.35E-09 1.10E-10 2.32E+00 13 Sr-92 1.90E+00 3.83E-05 3.12E-09 3.45E-09 1.90E+00 14 Y-90 3.90E-03 9.53E-08 8.36E-12 8.91E-12 3,90E-03 15 Y-91 2.70E-02 5.66E-07 4.69E-11 5.14E-11 1.31E-12 2,70E-02 16 Y-92 2.42E-01 7.01E-06 6.47E-10 6.73E-10 2.42E-01 17 Y-93 2.92E-02 6.05E-07 5.48E-11 2,92E-02 18 Zr-95 3.87E-02 8.1OE-07 6.69E-11 7.34E-11 1.87E-12 3,87E-02 19 Zr-97 3.781E-02 7,85E-07 6.47E-11 7.11E-11 3.78E-02 20 Nb-95 3.89E-02 8.13E-07 6.71E-11 7.37E-11 1.88E-12 3.89E-02 21 Mo-99 4,96E-01 1.04E-05 8.54E-10 9.38E-10 2.39E-11 4.96E-01 22 Tc-99m 4.42E-01 9.23E-06 7,63E-10 8.37E-10 4.42E-01 23 Ru-103 4.06E-01 8.50E-06 7.02E-10 7.70E-10 1.96E-11 4.06E-01 24 Ru-105 2.17E-01 4.44E-06 3.63E-10 4.OOE-10 2.17E-01 25 Ru-106 1,51E-01 3.17E-06 2.62E-10 2.87E-10 7.31E-12 1,51E-01 26 Rh-105 2.58E-01 5.39E-06 4.45E-10 4.89E-10 2.58E-01 27 Sb-127 5.60E-01 1,17E-05 9.65E-10 1.06E-09 2.70E-11 5.60E-01 28 Sb-129 1,33E+00 2.72E-05 2.22E-09 2.45E-09 1,33E+00 29 Te-127 5.60E-01

1. E-05 9.66E-10 1.06E-09 5.60E-01 30 Te-127m 7.50E-02 1.57E-06 1.30E-10 1.42E-10 3.62E-12 7.50E-02 31 Te-129 1.47E+00 3.03E-05 2.49E-09 2.74E-09 1,47E+00 32 Te-129m 2.50E-01 5.22E-06 4.31E-10 4.73E-10 1.21E-11 2,50E-01 33 Te-131m 7.40E-01 1.54E-05 1.27E-09 1.40B-09 3.55E-11

.7.40E-01 "34 Te-132 7.46E+00 1.56E-04 129E-08 f41.41E-08 3,.60E-10 ------

.46E+00 35 1-131 1.90E+00 3.70E+01 4.90E-03 1.14E-03 7.70E-04 2.OOE-03 1.85E+00 4.05E+01 8.13E+01 36 1-132 2.71E+00 4.54E+01 5.38E-03 1.19E-03 8.26E-04 2.08E-03 2.64E+00 3.87E+01 8.94E+01 37 1-133 3.89E+00 7.28E+01 9.60E-03 2.22E-03 1.51E-03 3.91E-03 3.80E+00 7.97E+01 1,60E+02 38 1-134 4.11E+00 2.91E+01 3.34E-03 7.27E-04 5.09E-04 1.27E-03 4.02E+00 3,17E+01 6,90E+01 39 1-135 3.62E+00 6.15E+01 8.02E-03 1.85E-03 1.26E-03 3.25E-03 3.54E+00 I_ 6.73E+01 136E+02

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-3 A

B C

D E

F G

H I

d 40 Xe-133 3.79E+00 2.42E+04 1.03E+01 3.28E+00 2.29E+00 6.04E+00 9.99E-04 2.66E+02 2.45E+04 41 Xe-135 1.82E+00 1.17E+04 4.88E+00 1.53E+00 1.08E+00 2.82E+00 1.13E-02 2.71E+03 1.45E+04 42 Cs-134 4.30E-01 7.18E+00 1.91E-04 1,87E-08 1.85E-08 5.47E-10 7.61E+00 43 Cs-136 1.44,.

C.....

s........6.-------.-.--------....4-4..9.61...-.-.--...----...-................................................................6.23 909 44 Cs-137 2.74E-01 4.57E+00 1,22E-04 1.19E-08

1. 18E-08 3.48E-10 4.84E+00 45 Ba-139 1,83E+00 3.55E-05 2.84E-09 3.17E-09 1.83E+00 46 Ba-140 3.76E+00 7.85E-05 6.48E-09 7.12E-09 1.81E-10 3.76E+00 47 La-140 7.63E-02 1.95E-06 1.74E-10 1.84--10 7.63E-02 48 La-141 2.72E-02 5.54E-07 2.72E-02 49 La-142 1.75E-02 3.42E-07 1,75E-02 50 Ce-141 8,95E-02 1.87E-06 1.54E-10 1.70E-10 4.32E-12 8,95E-02 51 Ce-143 8.01E-02 1.67E-06 1.38E-10 1.51E-10 8.01E-02 52 Ce-144 7.36E-02 1.54E-06 1.27E-10 1.40E-10 3.56E-12 7.36E-02 53 Pr-143 3.22E-02 6.74E-07 5.57E-11 1

6.11E-11 3,22E-02 54 Nd-147 1.42E-02 2.97E-07 2.45E-i1 I

2.69E-11 1.42E-02 55 Np-239 1.04E+00 2.17E-05 1.79E-09 I

1.97E-09 5.01E-11 1.04E+00 56 Pu-238 2.18E-04 4.55E-09 3.76E-13 I

4.13E-13 1.05E-14 2.18E-04 57 Pu-239 2.38E-05 4.97B-10

4. 1OE-14 1

4.50E-14 1.15E-15 2.38E-05 58 Pu-240 3.17E-05 6.62E-10 5.47E-14 I

6.OOE-14 1.53E-15 3.17E-05 59 Pu-241 9.13E-03 1.91E-07 1.58E-11 1

1.73E-11 4.41E-13 9.13E-03 60 Am-241 4.57E-06 9.56E-11 7.90E-15 8.67E-15 2.21E-16 4.57E-06 61 Cm-242 1.06E-03 2.22E-08 1.83E-12 2.01E-12 1.06E-03 62 Cm-244 5.57E-05 1.16E-09 9.61E-14 1,06E-13 5.57E-05 63 1

164,i 1651

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-4 A

B C

D E

F I

H I

H 66 BNP EPU/AST - LOCA Activity (Curies) in Environment at 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 67 Isotope PLKG-RB PLKG-ST MSIV-SCB

-PCI-SCB RCIC-SCB MSIV-LKG ESF-RB ESF-ST Total 68 Co-58 3.7213-03 8,64E-07 1.96E1-10 1.05E-0 9.32E-12

.3

.72E-03 6 8~..

.o 5

3...

7 E 0 8.4 0 1..96E 1

1..

9-. -

1....................

.......................................................: -E i03 69 Co-60 4.46E-03 1.041-06 2.35E-10 1

1.25E-10 1.12E-11 4.46E-03 70 Kr-85 2.58E-02 1.40E+03 3.90E+00 2.95E+00 1.11E+00 8.41E+00 1.42E+03 71 Kr-85m 5.06E-01 1.42E+04 3.26E+01 2,36E+01 9.19E+00 6.55E+01 1.43E+04 72 Kr-87 9.51E-01 7.32E+03 9.90E+00 6.19E+00 2.68E+00 1.56E+01 7.36E+03 73 Kr-88 1.36E+00 2.72E+04 5.55E+01 3.91E+01 1.5519+01 1.06E+02 2.74E+04 74 Rb-86 4.73E-03 1.70E-01 4.05E-05 9.25E-09 4.91E-09 4.43E-10 1.75E-01 75 Sr-89 5.10E+00 1.18E-03 2.69E-07 1.43E-07 1.28E-08 5.1OE+00 76 Sr-90 5.67E-01 1.32E-04 2.99E-08 1.60E-08 1.42E-09 5.67E-01 77 Sr-91 5.34E+00 1.03E-03 2.27E-07 1.24E-07 1.06E-08 5.34E+00 78 Sr-92 3.78E+00 4.75E-04 9.69E-08 5.61E-08 4.25E-09 3.78E+00 79 Y-90 1.44E-02 7.OOE-06 1.70E-09 1

8.61E-10 8.52E-11 1,44E-02 80 Y-91 6.72E-02 1.62E-05 3.70E-09 1.96E-09 1.76E-10 6,72E-02 81 Y-92 9.45E-01 3.599E-04 8.45E-08 4.40E-08 4.06E-09 9,45E-01 82 Y-93 6.75E-02 1.31E-05 2.91E-09 1.58E-09 1.35E-10 6.75E-02 83 Zr-95 9.53E-02 2.21E-05 5.03E-09 2.68E-09 2.39E-10 9.53E-02 84 Zr-97 8.94E-02 1.87E-05 4.18E-09 2.25E-09 1.96E-10 8.95E-02 85 Nb-95 9.56E-02 2.22E-05 5.05E-09 2.69E-09 2.40E-10 9.57E-02 86 Mo-99 1.21E+00 2.73E-04 6.18E-08 3.30E-08 2.93E-09 1.21E+00 87 Tc-99m 1.08E+00 2.50E-04 5.67E-08 3.03E-08 2.69E-09 1.081E+00 88 Ru-103 9.99E-01 2.32E-04 5.27E-08 2.8 1E-08 2.50E-09 9.99E-01 89 Ru-105 4.65E-01 7.31E-05 1.56E-08 8.73E-09 7.07E-10 4.65E-01 90 Ru-106 3.73E-01 8.66E-05 1.97E-08 S1.05E-08 9.34E-10 3.73E-01 91 Rh-105 6.31E-01 1.44E-04 3.25E-08 1.74E-08 1.54E-09 6.31E-01 92 Sb-127 1.37E+OO 3.12E-04 7.06E-08 3.77E-08 3.35E-09 1.37E+00 93 Sb-129 2.84E+00 4.42E-04 9.42E-08 5.28E-08 4.26E-09 2.84E+00 94 Te-127 1.37E+00 3.16E-04 7.16E-08 3.82E-08 3.40E-09 1.37E+00 95 Te-127m 1.85E-01 4.29E-05 9.76E-09 5.20E-09 4.63E-10 1.85E-01 96 Te-129 3.27E+00 5.60B-04 1.21E-07 6.71E-08 5.55E-09 3.27E+00 97 Te-129m 6.14E-01 1.43E-04 3.24E-08 1.73E-08 1.54E-09 6.14E-01 98 Te-131m 1.785+00 3.89E-04 8.77E-08 4.71E-08 4.14E-09 1.78E+00 99 Te-132 1.82E+i01 4.135-03 9.36E-07

],5.00E-07 4.435-08 1.82E+01 100 1-131 1,90E+00 9.24E+01 1.88E-01

'105E-01 4.07E-02 2.831-01 1.85E+00 3.01E+02 3.97E+02 101 1-132 2.71E+00 9.25E+01 8.97E-02 4.55E-02 1.84E-02 1.181-01 2.64E+00 1.34E+02 2.33E+02 102 1-133 3.89E+00 1.75E+02 3.27E-01 1.811-01 7.04E-02 4.8513-01 3.80E+00 5.40E+02 7.24E+02 103 1-134 4.11E+00 4.05E+01 1.33E-02 5.16E-03 1

2.49E-03 1.15E-02 4.02E+00 5.65E+01 1.05E+02 104 1-135 3.62E+00 1.36E+02 2.07E-01 1.12E-01 4.41F-02 2.96E-01 3.545+00 3.72E+02 5.155+02

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-5 A

B C

D E

F G

H I

J 105 Xe-133 3.79E+00 2.02E+05 5.58E+02 4.21E+02 1.59E+02 1.20E+03 9.99E-04 1.03E+04 2.15E+05 106 Xe-135 1.82E+00 8.39E+04 2.11E+02 1.57E+02 5.99E+01 4.43E+02 1.13E-02 7.90E+04 1.64E+05 107 Cs-134 4.30E-01 1.56E+01 3.71E-03 8.49E-07 4.50E-07 4.07E-08 1.60E+01 108 Cs-136 1.44E-01 5.17E+00 1.23E-03 2.80E-07 1.49E-07 1.34E-08 5.31E+00 109 Cs-137 2.74E-01 9.90E+00 2.36E-03 5.40E-07 1

2.87E-07 2.59E-08 1.02E+01 110 Ba-139 3.13E+00 2.46E-04 4.43E-08 2.8 1E-08 1.79E-09 3.13E+00 111 Ba-140 9.22E+00 2.13E-03 4.84E-07 2.58E-07 2.30E-08 9.22E+00 112 La-140 3.11E-01 1.65E-04 4.03E-08 2.03E-08 2.02E-09 3.12E-01 113 La-141 5.74E-02 8.60E-06 1.82E-09 I

1.02E-09 5.74E-02 114 La-142 3.08E-02 2.65E-06 4.90E-10 3.08E-02 115 Ce-141 2.20E-01 5.1OE-05 1.16E-08 6.18E-09 5.50E-10 2.20E-01 116 Ce-143 1.93E-01 4.25E-05 9.58E-09 5.14E-09 4.52E-10 1,93E-01 117 Ce-144 1.81E-01 4.21E-05 9.57E-09 5.1OE-09 4.54E-10 1.81E-01 118 Pr-143 7.95E-02 1,86E-05 4.23E-09 2.25E-09 2.01E-10 7.95E-02 119 Nd-147 3.48E-02 8.04E-06 1.83E-09 9.74E-10 8.66E-11 3.49E-02 120 Np-239 2.53E+00 5.69E-04 1.29E-07 i

6.88E-08 6.09E-09 2.53E+00 121 Pu-238 5.36E-04 1.25E-07 2.83E-11 i1.51E-11 1.34E-12 5.36E-04 122 Pu-239 5.85E-05 1.36E-08 3.09E-12 1.65E-12 1.47E-13 5.85E-05 123 Pu-240 7.79E-05 1.81E-08 4.12E-12 2.19E-12 1.96E-13 7.80E-05 124 Pu-241 2.25E-02 5.22E-06 1.19E-09 6.32E-10 5.63E-11 2.25E-02 125 Am-241 1.13E-05 2.62E-09 5.95E-13 I

3.17E-13 2.83E-14 1.13E-05 126 Cm-242 2.61E-03 6.06E-07 1.38E-10 I

7.34E-11 6.54E-12 2.61E-03 127 Cm-244 1.37E-04 3.18E-08 7.24E-12 3.86E-12 3.44E-13 1.37E-04 128 129 130i __

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-6 A

B C

D I

E F

G H

I J

131 BNP EPU/AST - LOCA Activity (Curies) in Environment at 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />....

132 Isotope PLKG-RB PLKG-ST MSIV-SCB HPCI-SCB RCIC-SCB MSIV-LKG ESF-RB ESF-ST

[

Total 133 Co-58 3.76E-03 3.31E-06 8.70E-10 4.11E-10 5.58E-11 3.76E-03 134 Co-60 4.51E-03 3,98E-06 1.05E-09 4.95E-10 6.71E-11 4.51E-03 135 Kr-85 2.58E-02 4.70E+03 4.32E+01 3.97E+01 1.28E+01 1.53E+02 4.95E+03 136 Kr-85m 5,06E-01 2.09E+04 9.62E+01 8.19E+01 2.80E+01 2.85E+02 2.14E+04 137 Kr-87 9.51E-01 7.50E+03 1.11E+01 7.26E+00 3.04E+00 1.94E+01 7.54E+03 138 Kr-88 1.36E+00 3.32E+04 1.06E+02 8.52E+01 3.0519+01 2.76E+02 3.37E+04 139 Rb-86 4.73E-03 1.72E-01 1.51E-04 3.96E-08 j

1.87E-08 2.54E-09 1.77E-01 140 Sr-89 5.15E+00 4.53E-03 1.19E-06 j

5.62E-07 7.62E-08 5.16E+00 141 Sr-90 5.73E-01 5.07E-04 1.33E-07 j

6.29E-08 8.54E-09 5.74E-01 142 Sr-91 5.38E+00 2.39E-03 6.03E-07 2.95E-07 3.61E-08 5.38E+00 143 Sr-92 3.79E+00 6.12E-04 1.34E-07 I

7.32E-08 6.71E-09 3.79E+00 144 Y-90 1.51E-02 6.70E-05 1.82E-08 I

8.38E-09 1.24E-09 1.51E-02 145 Y-91 6.80E-02 6.65B-05 1.76E-08 8.26E-09 1,13E-09 6.81E-02 146 Y-92 9.58E-01 7.82E-04 2,01E-07 9.69E-08 1.19E-08 9.59E-01 147 Y-93 6.79E-02 3.13E-05 7.92E-09 3.86E-09 4.76E-10 6.80E-02 148 Zr-95 9.63E-02 8.48E-05 2..23E-08 lO 1.0E-08 1.43E-09 9.64E-02 149 Zr-97 9.02E-02 5.29E-05 1.36E-08 1

6.53E-09 8.40E-10 9.02E-02 150 Nb-95 9.67E-02 8.55E-05 2.25E-08 1.06E-08 1.44E-09 9.68E-02 151 Mo-99 1,22E+00 9.65E-04 2.52E-07 1.20E-07 1.60E-08 1.22E+00 152 Tc-99m 1.10E+00 9.20E-04 2.41E-07 i

1.14E-07 1.54E-08 1.10OE+00 153 Ru-103 1.01E+00 8.86E-04 2.33E-07 1.10E-07 1.49E-08 1.01E+00 154 Ru-105 4.67E-01 1.19E-04 2.82E-08 1.45E-08 1.55E-09 4.67E-01 155 Ru-106 3.77E-01 3.33E-04 8.75E-08 4.13E-08 5.61E-09 3.77E-01 156 Rh-105 6.38E-01 4.91E-04 1.28E-07 6.08E-08 8.11E-09 6.38E-01 157 Sb-127 1.38E+00 1.13E-03 2.95E-07 1.40E-07 1.88E-08 1.38E+00 158 Sb-129 2.85E+00 7.10E-04 1,68E-07 I

8.62E-08 9.16E-09 2.85E+00 159 Te-127 1.39E+00 1.17E-03 3.08E-07 1.46E-07 1.97E-08 1.39E+00 160 Te-127m 1.87E-01 1.65E-04 4.34E-08 2.05E-08 2.78E-09 1.87E-01 161 Te-129 3.28E+00 1.19E-03 2.95E-07 1.46E-07 1.74E-08 3.29E+00 162 Te-129m 6.21E-01 5.46E-04 1.44E-07 6.78E-08 9.19E-09 6.21E-01 163 Te-131m 1.80E+00 1.25E-03 3.25E-07 1.55E-07 2.04E-08 1.80E+00

~~~~~~~~~~~

~ ~ ~ ~ ~ ~ ~ ~ ~

164 Te-132 1.84E+01 1.48E-02 3.87E-06 1.84E-06 2.46E-07 1.84E+01 165 1-131 1.90E+00 1.27E+02 1.84E+00 1.33E+00 4.39E-01 4.79E+00 1.85E+00 9,54E+02 1.09E+03 166 1-132 2.71E+00 9.47E+01 1.59E-01 8.78E-02 3.22E-02 2.93E-01 2.64E+00 1,52E+02 2.53E+02 167 1-133 3.89E+00 2.20E+02 2.34E+00 1.67E+00 5.56E-01 5.93E+00 3.80E+00 1.38E+03 1.61E+03 168 1-134 4.11E+00 4.05E+01 1.36E-02 5.36E-03 2+56E-03 1.22E-02 4.02E+00 5.67E+01 1.05E+02 169 1-135 3.62E+00 1.51E+02 7.95E-01 5.40E-01 1

1.85E-01 1.83E+00 3.54E+00 6.43E+02 8.04E+02

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-7

_ A B

C D

E F

G H

I J

170 Xe-133 3.79E+00 6.49E+05 5.84E+03 5.35E+03 1.72E+03 2.06E+04 9.99E-04 8.94E+04 7.71E+05 171 Xe-135 1.82E+00 1.71E+05 1.13E+03 1.01E+03 3.31E+02 3.73E+03 1.13E-02 3.56E+05 5.33E+05 172 Cs-134 4,30E-01 1.57E+01 1,40E-02 3.68E-06 1.74E-06 2.36E-07 1.62E+01 173, Cs-136 1.44E-01 5.22E+i00 4.54E-03

1. 19E-06 5.63E-07 7.63E-08 5.37E+00 174 Cs-137 2.74E-01 1.O0E+01 8.91E-03 2.34E-06 1.11E-06 1.50E-07 1.03E+01 175 Ba-139 3.13E+00 2.60E-04 4.80E-08 2.98E-08 2.03E-09 3.13E+00 176 Ba-140 9.32E+00 8.04E-03 2.11E-06 9.98E-07 1.35E-07 9.33E+00 177 La-140 3.27E-01 1.58E-03 4.31E-07 1.98p-07 2.92E-08 3.29E-01 178 La-141 5.75E-02 1.32E-05 3.07E-09 1

1.59E-09 1.65E-10 5.76E-02 179 La-142 3.08E-02 2.85E-06 5.46E-10 3.08E-02 180 Ce-141 2.22E-01 1.95E-04 5.12E-08 2.42E-08 3.28E-09 2.23E-01 181 Ce-143 1.95E-01 1.39E-04 3.61E-08 1.72E-08 2.27E-09 1.95E-01 182 Ce-144 1.83E-01 1.62E-04 4.25E-08 2.01E-08 2.73E-09 1.83E-01 183 Pr-143 8.04E-02 7.28E-05 1.92E-08 1

9.04E-09 1.23E-09 8.04E-02 184 Nd-147 3.52E-02 3.03E-05 7.95E-09 3.76E-09 5.08E-10 3.53E-02 185 Np-239 2.55E+00 1.98E-03 5.18E-07 I

2.46E-07 3.29E-08 2.55E+00 186 Pu-238 5.42E-04 4.79E-07 1.26E-10 5.95E-11 8.07E-12 5.42E-04 187 Pu-239 5.91E-05 5.24E-08 1.38E-11 6.50E-12 8.82E-13 5.92E-05 188 Pu-240

-7.88E-05 6.97E-08 1.83E-11 I

8.65E-12 1.17E-12 7.89E-05 189 Pu-241 2.27E-02 2,01E-05 5.28E-09 2.49E-09 3.38E-10 2.27E-02 190 Am-241 1.14E-05 1.01E-08 2.66E-12 1.25E-12 1.70E-13 1.14E-05 191 Cm-242 2,64E-03 2,33E-06 6.12E-10 2.89E-10 3.92E-11 2.64E-03 192 Cm-244 1.39E-04 1.22E-07 3.22E-11 1.52E-11 2.06E-12 1.39E-04 193 194 1 195 1,,,

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-8 A

B C

D E

F G

H 196 BNP EPU/AST - LOCA Activity (Curies) in Environment at 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> 197 Isotope PLKG-RB PLKG-ST MSIV-SCB

-PCI-SCB i

RCIC-SCB MSIV-LKG ESF-RB ESF-ST Total 198 Co-58 3.76E-03 3.35E-06 8.80E-10 4.16E-10 2.35E-10 3.77E-03 199 Co-60 4.51E-03 4.03E-06 1.06E-09 i

5... E-10 2.87E-10 4,51E-03 200 Kr-85 2.58E-02 1.65E+04 5.85E+02 5.72E+02 1.75E+02 2.84E+03 2.07E+04 201 Kr-85m 5,06E-01 2.14E+04 1.08B+02 9.38E+01 3,16E+01 3.38E+02 2.20E+04 202 Kr-87 9.51E-01 7.50E+03 1.11E+01 7.26E+00 3.04E+00 1.94E+01 7.54E+03 203 Kr-88 1.36E+00 3.33E+04 1.09E+02 8.73E+01 3.12]J+01 2.85E+02 3,38E+04 204 Rb-86 4.73E-03 1.72E-01 1.52E-04 4.OOE-08 1.89E-08 1.02E-08 1.77E&01 205 Sr-89 5.15E+00 4.58E-03 1.20E-06 5.68E-07 3.20E-07 5.16E+00 206 Sr-90 5.73E-01 5.13E-04 1.35E-07 6.36E-08 3.65E-08 5.74E-01 207 Sr-91 5.38E+00 2.40E-03 6.04E-07 2.95E-07 4.66E-08 5,38E+00 208 Sr-92 3.79E+00 6.12E-04 1.34E-07 7.32E-08 6.75E-09 3.79E+00 209 Y-90 1.51E-02 6.97E-05 1.90E-08 8.71E-09 1.42E-08 1.52E-02 210 Y-91 6.80E-02 6.73E-05 1.78E-08 8.36E-09 5.06E-09 6.81E-02 211 Y-92 9.58E-01 7.82E-04 2.01E-07 9.69E-08 1.24E-08 9.59E-01 212 Y-93 6.79E-02 3.14E-05 7.92E-09 3.86E-09 6.31E-10 6.80E-02 213 Zr-95 9.64E-02 8.57E-05 2.25E-08 1.06E-08 6.01E-09 9.64E-02 214 Zr-97 9.02E-02 5.30E-05 1.36E-08 6,55E-09 1.43E-09 9.02E-02 215 Nb-95 9.67E-02 8.64E-05 2.27E-08 1.07E-08 6.15E-09 9.68E-02 216 Mo-99 1,22E+00 9.72E-04 2.54E-07 1,21E-07 4.95E-08 1.22E+00 217 Te-99m 1.10E+00 9.27E-04 2.43E-07 1.15E-07 4.96E-08 1.10E+00 218 Ru-103 1.01E+00 8.96E-04 2.36E-07 1.11E-07 6.22E-08 1.01E+00 219 Ru-105 4.67E-01 1.19E-04 2.82E-08 1.45E-08 1.62E-09

_4.67E-01 220 Ru-106 3.77E-01 3.37E-04 8.85E-08 4.18E-08 2.39E-08 3.77E-01 221 Rh-105 6.38E-01 4.93E-04 1.29E-07 6.12E-08 2.03E-08 6.38E-01 222 Sb-127 1.38E+00 1.14E-03 2.98E-07 1.41E-07 6.33E-08

_1.38E+00 223 Sb-129 2.85E+00 7.1OE-04 1.68E-07 8.62E-08 9.54E-09 2.85E+00 224 Te-127 1.39E+00 1.18E-03 3.11E-07 j

1.47E-07 7.08E-08 1.39E+00 225 Te-127m 1.87E-01 1.67E-04 4,40E-08 j

2.07E-08 1.19E-08 1.87E-01 226 Te-129 3.28E+00 1.20E-03 2.97E-07 i

1.47E-07 4.30E-08 3.29E+00 227 Te-129m 6.21E-01 5.52E-04 1.45E-07 6.85E-08 3.82E-08 6,21E-01 228 Te-131m 1.80E+00 1.26E-03 3.26E-07 I

1.55E-07 4.67E-08 1.80E+00 229 Te-132 1.84E+01 1.49E-02 3.90E-06 1.85E-06 7.97E-07 1.84E+01 230 1-131 1.90E+00 2.32E+02 1.59E+01 1.51E+01 4.65E+00 7.43E+01 1.85E*+00 3.28E+03 3.62E+03 231 1-132 2.71E+00 9.48E+01 1.79E-01 8.87E-02 I

3.25E-02 2.98E-01 2.64E+00 1.52E+02 2.53E+02 232 1-133 3.89E+00 2,65E+02 7.31E+00 6.51E+00 2.04E+00 2.96E+01 3.80E+00 2.39E+03 2.71E+03 233 1-134 4.11EE+00 4.05E+01 1.36E-02 5.36E-03 2.56E-03 1.22E-02 4.02E+00 5.67E+01 1.05E+02 234 1-135 3.62E+00 1.53E+02 1.01E+00 7.46E-01 I

2.48E-01 2.77E+00 3.54E+00 7.02E+02 8.66E+02

Calculation No. BNP-RAD-007 Revision I Attachment No. 98 Page 98-9 A

B C

D E

F G

H I

d 235 Xe-133 3.79E+00 1.91E+06 6.17E+04 6.02E+04 1.85E+04 2.96E+05 9.99E-04 6.88E+05 3.03E+06 236 Xe-135 1.82E+00 2.OOE+05 2.OOE+03 1.85E+03 5.91E+02 7.68E+03 1.13E-02 5,78E+05 7.91E+05 237 Cs-134 4.30E-01 1.57E+01 1.41E-02 3.72E-06 1.76E-06 OOE-06 6.2..1" 238 Cs-136 1.44E-01 5.22E+00 4.58E-03 1.206-06

[

5.69E-07 3.01E-07 5.37E+00 239 Cs-137 2.74E-01 1,OOE-01 9.01E-03 2.37E-06 1

1.12E-06 6.38E-07 1.03E+01 240 Ba-139 3.13E+0O 2.60E-04 4,80E-08 2.98E-08 2.03E-09 3.13E+00 241 Ba-140 9.32E+00 8.13E-03 2.14E-06 1,01E-06 5.35E-07 9.33E+00 242 La-140 3.27E-01 1.64E-03 4.46E-07 2.05P-07 2.89E-07 3.29E-01 243 La-141 5.75E-02 1,32E-05 3.07E-09 1.60E-09 1.70E-10 5.76E-02 244 La-142 3.08E-02 2,85E-06 5.46E-10 3.08E-02 245 Ce-141 2.22E-01 1,97E-04 5.18E-08 2.45E-08 1.36E-08 2.23E-01 246 Ce-143 1.95E-01 1,39E-04 3.62E-08 1,73E-08 5,43E-09 1.95E-01 247 Ce-144 1.83E-01 1.64E-04 4.30E-08 2.03E-08 1.16E-08 1.83E-01 248 Pr-143 8.04E-02 7.36E-05 1.94E-08 1

9.14E-09 5.30E-09 8.04E-02 249 Nd-147 3.52E-02 3.06E-05 8.03E-09 1

3.79E-09 1.99E-09 3.53E-02 250 Np-239 2.55E+00 2.OOE-03 5.22E-07 2.47E-07 9.68E-08 2.56E+00 251 Pu-238 5.42E-04 4.84E-07 1.27E-10 6.01E-11 3,45E-11 5.42E-04 252 Pu-239 5.91E-05 5.29E-08 1.39E-11 6.57E-12 3.78E-12 5.92E-05 253 Pu-240 7.88E-05 7.05E-08 1.85E-11 1

8.75E-12 5.02B-12 7.89E-05 254 Pu-241 2.27E-02 2.03E-05 5,34E-09 1

2.52E-09 1.45E-09 2.27E-02 255 Am-241 1.14E-05 1.02E-08 2.69E-12 1.27E-12 7.37E-13 1.14E-05 256 Cm-242 2.64E-03 2,35E-06 6,19E-10 2.92E-10 1.67E-10 2,64E-03 257 Cm-244 1.39E-04 1.24E-07 3.26E-11 1.54E-11 8.82E-12 1.39E-04 258 259 2601I

Calculation No. BNP-RAD-007 Revision I Attachment No. 98 Page 98-10 A

B C

D E

F G

H I

J 261 BNP EPU/AST - LOCA Activity (Curies) in Environment at 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> 262 Isotope PLKG-RB PLKG-ST MSIV-SCB HPCI-SCB RCIC-SCB MSIV-LKG ESF-RB ESF-ST Total 263 Co-58 3,76E-03 3.48E-06 9.18E-10 4.32B-10 8.98E-10 3.77E-03 0-0.

264 Co-60 4.51E-03 4.21E-06 1.11E-09 5.23E-10 1.19E-09 4.51E-03 265 Kr-85 2.58E-02 1.13E+05 1.98E+04 1.98E+04 6.01E+03 1.04E+05 2.63E+05 266 Kr-85m 5.06E-01 2.14E+04 1.08E+02 9.38E+01 3.16E+01 3.38E+02 2.20E+04 267 Kr-87 9.51E-01 7.50E+03 1.11E+01 7.26E+00 3.04E+00 1.94E+01 7.54E+03 268 Kr-88 1.36E+00 3.33E+04 1.09E+02 8.73E+01 3.121i+01 2.85E+02 3.38E+04 269 Rb-86 4.73E-03 1.72E-01 1.57E-04 4.12E-08 1.94E-08 3.16E-08 1.77E-01 270 Sr-89 5.16E+00 4,75E-03 1.25E-06 5.90E-07 1.18E-06 5.16E+00 271 Sr-90 5.74E-01 5.36E-04 1.41E-07 6.66E-08 1.52E-07 5.74E-01 272 Sr-91 5.38E+00 2.40E-03 6.04E-07 2.95E-07 4.67E-08 5.38E+00 273 Sr-92 3.79E+00 6.12E-04 1.34E-07.

7.32E-08 6.75E-09 3.79E+00 274 Y-90 1.53E-02 9.13E-05 2.49E-08 1.14E-08 1.21E-07 1.54E-02 275 Y-91 6.80E-02 7.02E-05 1.86E-08 8,72E-09 1.94E-08 6.81E-02 276 Y-92 9.58E-01 7.82E-04 2.01E-07 9,69E-08 1.24E-08 9.59E-01 277 Y-93 6.79E-02 3.14E-05 7.92E-09 3.86E-09 6.32E-10 6.80E-02 278 Zr-95 9.64E-02 8.91E-05 2.35E-08 I

1.11E-08 2.28E-08 9.65E-02 279 Zr-97 9.02E-02 5.30E-05 1.36E-08 1

6.55E-09 1.46E-09 9.02E-02 280 Nb-95 9.67E-02 9.03E-05 2.38E-08 1

1.12E-08 2.52E-08 9.68E-02 281 Mo-99 1.22E+00 9.76E-04 2.55E-07 1.21E-07 7.14E-08 1.22E+00 282 Tc-99m 1.10E+00 9.32E-04 2.44E-07 1.16E-07 7.21E-08 1.10E+00 283 Ru-103 1.01E+00 9.28E-04 2.45E-07 1

1.15E-07 2.23E-07 1.01E+00 284 Ru-105 4.67E-01 1.19E-04 2.82E-08 1.45E-08 1.62E-09 4.67E-01 285 Ru-106 3.77E-01 3.52E-04 9.27E-08 4.37E-08 9.78E-08 3.77E-01 286 Rh-105 6.38E-01 4.94E-04 1.29E-07 6.12E-08 2.35E-08 6.38E-01 287 Sb-127 1.38E+00 1.15E-03 3.OOE-07 1.42E-07 1.06E-07 1.38E+00 288 Sb-129 2.85E+00 7.10E-04 1.68E-07 8.62E-08 9.54E-09 2.85E+00 289 Te-127 1.39E+O0 1.20E-03 3.15E-07 j

1.49E-07 1.48E-07 1.39E+00 290 Te-127m 1.87E-01 1.74E-04 4.60E-08 2.17E-08 4.78E-08 1.87E-01 291 Te-129 3.28E+00 1.21E-03 3.02E-07 1.49E-07 1.26E-07 3.29E+00 292 Te-129m 6.21E-01 5.71E-04 1.50E-07 7.09E-08 1.34E-07 6.22E-01 293 Te-131m 1.80E+00 1.26E-03 3.27E-07 1.56E-07 5.17E-08 1.80E+00 294 Te-132 1.84E+O1 1.50E-02 3.93E-06 1.86E-06 1.24E-06 1.84E+O1 295 1-131 1.90E+00 5.38E+02 1.63E+02 1.62E+02 4.90E+01 8.55E+02 1.85E+00 7.96E+03 9.73E+03 296 1-132 2,71E+00 9.48E+01 1,96E-01 8.87E-02 I

3.25E-02 2.98E-01 2.64E+00 1.52E+02 2.53E+02 297 1-133 3.89E+00 2.69E+02 8.46E+00 7.64E+00 2.38E+00 3.56E+01 3.80E+00 2.47E+03 2.81E+03 298 1-134 4.11E+00 4.05E+01 1.36E-02 5.36E-03 2.56E-03 1.22E-02 4.02E+00 5.67E+01 1.05E+02 299 1-135 3.62E+00 1.53B+02 1.01E+00 7.46E-01 1

2.48E-01 2.78E+00 3.54E+00 7.02E+02 8.66E+02

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-11 A

B C

D E

F G

H I

J 300 Xe-133 3,79E+00 4.34E+06 4.14E+05 4.11E+05 1.25E+05 2.17E+06 9.99E-04 1.80E+06 9.27E+06 301 Xe-135 1.82E+00 2.OOE+05 2.OOE+03 1.86E+03 5.93E+02 7.73E+03 1.13E-02 5.79E+05 7.92E+05 302 Cs-134 4.30E-01 1.57E+01 1.48E-02 3.90E-06 1,84E-06 4.12E-06 1.62E+01 8-2----------------.5 7 E +1-...............

E.........................

1--8-----------..

.......----1 2------.6--...............................................................................-

2 E +..

1 303 Cs-136 1,44E-01 5.22E+00 4.69E-03 1.24E-06 1

5.83E-07 8.41E-07 5.37E+00 304 Cs-137 2,74E-01 1.OOE+01 9.41E-03 2.48E-06 1, 17E-06 2.65E-06 1.03E+01 305 Ba-139 3.13E+00 2.60E-04 4,80E-08 2,98E-08 2.03E-09 3.13E+00 306 Ba-140 9.32E+00 8.32E-03 2.19E-06 1,03E-06 1.49E-06 9.33E+00 307 La-140 3,29E-01 1.85E-03 5.04E-07 2.31E-07 1.33E-06 3.31E-01 308 La-141 5,75E-02 1.32E-05 3.0'7E-09 1,60E-09 1.70E-10 5.76E-02 309 La-142 3.08E-02 2,85E-06 5.46E-10 3.OSE-02 310 Ce-141 2.22E-01 2.04E-04 5.37E-08 2.53E-08 4,74E-08 2.23E-01 311 Ce-143 1.95E-01 1.39E-04 3,63E-08 1.73E-08 6.15E-09 1.95E-01 312 Ce-144 1.83E-01 1.71E-04 4.50E-08 2.12E-08 4.73E-08 1.83E-01 313 Pr-143 8.04E-02 7.58E-05 2.OOE-08 1

9,42E-09 1.61E-08 8.04E-02 314 Nd-147 3.52E-02 3.12E-05 8.21E-09 1

3.88E-09 5.24E-09 3.53E-02 315 Np-239 2.55E+00 2.OOE-03 5.24E-07 2.48E-07 1.31E-07 2.56E+00 316 Pu-238 5.42E-04 5.07E-07 1.34E-10 6.29E-11 1.44E-10 5.43E-04 317 Pu-239 5-92E-05 5.54E-08 1.46E-11 6,88E-12 1.58E-11 5.92B-05 3 17'~~~~~~~~~~~~~~~~

-u23 2E 0 4...-1 5_8-E-.1.-.

.................................................... 2.

318 Pu-240 7.88E-05 7.37E-08 1.94E-11 i

9.15E-12 2.09E-11 7.89E-05 319 Pu-241 2.27E-02 2.12E-05 5.60E-09 2.64E-09 6.01E-09 2.27E-02 320 Am-241 t1.14E-05 1.07E-08 2.83E-12 1.33E-12 3.30E-12 1.14E-05 321 Cm-242 2.64E-03 2.46E-06 6.47E-10 3.05E-10 6.68E-10 2.64E-03 322 Cm-244 1.39E-04 1.29E-07 3.41E-11 1.61E-11 3.67E-11 1.39E-04 323 3241 13251!

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-12 A

B C

D E

F G

H I

d 326 BNP UFSAR Table 15.6.4-3 327 Integrated Activity Released to Environment (Curies) - Design Basis LOCA 328 Isotope T = 0 Hrs T2xs T= 8 Hrs T = 24 Hr i

T 96"Hr T = 720 Hr 3 2- -6 c ; s g....

329 Co-58 0.00E4-001 1.51E-03 3.72E-03 3.76E-03 3.77E-03 3,77E-03 330 Co-60 0.00E+00 1.81E-03 4.46E-03 4.51E-03 4.51E-03 4.51E-03 331 Kr-85 O.00E+00 1.65E+02 1.42E+03 4.95E+03 2.07E+04 2.63E+05 332 Kr-85m 0.00E+00 2.59E+03 1.43E+04 2.14E+04 2.20E+04 2.20E+04 333 Kr-87 O.OOE+00 2.82E+03 7.36E+03 7.54E+03 7.54VL+03 7.54E+03 334 Kr-88 0,00E+00 6.15E+03 2.74E+04 3.37E+04 3.38E+04 3.38E+04 335 Rb-86 0.OOE+00 8.34E-02 1.75E-01 1.77E-01 1.77E-01 1.77E-01 336 Sr-89 0.00E+00 2.07E+00 5.10E+00 5.16E+00 5.16E+00 5.16E+00 337 Sr-90 0.OOE+00 2.30E-01 5.67E-01 5.74E-01 i

5.74E-01 5.74E-01 338 Sr-91 0.OOE+00 2.32E+00 5,34E+00 5.38E+00 5.38E+00 5.38E+00 339 Sr-92 0.OOE+00 1.90E+00 3.78E+00 3.79E+00 3.79E+00 3.79E+00 340 Y-90 0.OOE+00 3.90E-03 1,44E-02 1.51E-02 1.52E-02 1.54E-02 341 Y-91 0.00E+00 2.70E-02 6.72E-02 6.81E-02 6.81E-02 6.81E-02 342 Y-92 0.00E+00 2.42E-01 9.45E-01 9.59E-01 9.59E-01 9.59E-01 343 Y-93 O.00E+00 2.92E-02 6.75E-02 6.80E-02 6.80E-02 6.80E-02 344 Zr-95 O.00E+00 3.87E-02 9.53E-02 9.64E-02 1"9.64E-02 9.65E-02 345 Zr-97 O.OOE+00 3.78E-02 8.95E-02 9.02E-02 9.02E-02 9.02E-02 346 Nb-95 0.00E+00 3.89E-02 9.57E-02 9.68E-02 9.68E-02 9.68E-02 347 Mo-99 0.00E+00 4.96E-01 1.21E+00 1.22E+00 1.22E+00 1.22E+00 348 Tc-99m O.OOE+00 4.42E-01 1.OSE+00 1.10E+00 1.1OE+00 1.1OE+00 349 Ru-103

).00E+00 4.06E-01 9.99E-01 1.01E+00 1.01E+00 1.01E+00 350 Ru-105 O.OOE+00 2.17E-01 4.65E-01 4.67E-01 4.67E-01 4.67E-01 351 Ru-106 O.OOE+00 1.51E-01 3.73E-01 3.77E-01 3.77E-01 3.77E-01 352 Rh-105 O.OOE+00 2.58E-01 6.31E-01 6.38E-01 6.38E-01 6.38E-01 353 Sb-127 O.OOE+00 5.60E-01 1.37E+00 1.38E+00 i

1.38E+00 1.38E+00 354 Sb-129 0.OOE+00 1.33E+00 2.84E+00 2.85E+00

__2.85E+00 2.85E+00 355 Te-127 O.OOE+00 5.60E-01 1.37E+00 1.39E+00 1.39E+00 1.39E+00 356 Te-127m 0.00E+00 7.50E-02 1.85E-01 1.87E-01 1.87E-01 1.87E-01 357 Te-129 0.00E+00 1.47E+00 3.27E+00 3.29E+00 3.29E+00 3.29E+00 358 Te-129m O.OOE+00 2.50E-01 6.14E-01 6.21E-01 0 6.21E-01 6.22E-01 359 e-11m

.008+00 7.40E-01 1.78EO

.OOO 1OE+00 1.80E+00 360 Te-132 O.OOE+00 7.46E+00 1.82E+01 1.84E+01 1

1.84E+01 1.84E+01 36111-131 0.OOE+00 8.13E+01 3.97E+02 1.09E+03 3.62E+03 9.73E+03 362 1-132 O.OOE+00 8.94E+01 2.33E+02 2.53E+02 2.53E+02 2.53E+02 363 1-133 0.00E+00 1.60E+02 7.24E+02 1.61E+03 2.71E+03 2.81E+03 364 1-134 0.00E+00 6.90E+01 1.05E+02 1.05E+02 1.05E+02 1.05E+02

Calculation No. BNP-RAD-007 Revision 1 Attachment No. 98 Page 98-13 A

B C

D E

F G

H I

365 1-135 0.OOE+00 1.36E+02 5.15E+02 8.04E+02 8.66E+02 8.66E+02 366 Xe-133 0.OOE+00 2.45E+04 2.15E+05 7.71E+05 3.03E+06 9.27E+06 367 Xe-135 0.OOE+00 1.45E+04 1.64E+05 5.33E+05 7.91E+05 7,92E+05

-" -- 3....

0.

0--

0-i+ 6.................

0 2E 0 E+ 0--

368, Cs-134 0.OOE+00 7.61 E+00 1.60E+01 1.62E+01 1.62E+01 1,62E+01 369 Cs-136 0.00E+00 2.53E+00 5.31E+00 5,37E+00 1

5.37E+00 5.37E+00 370 Cs-137 0.00E+00 4.84E+00 1.02E+01 1.03E+01 1

1.03E+01 1.03E+01 371 Ba-139 0.00E+00 1.83E+00 3.13E+00 3.13E+00 3.13E+00 3.13E+00 372 Ba-140 0.00E+00 3.76E+00 9.22B+00 9.33E+00

,i 9.33F,+00 9.33E+00 373 La-140 0.00E+00 7.63E-02 3112E-01 3.29E-01 3.29E-01 3.31E-01 374 La-141 0.00E+00 2.72B-02 5.74E-02 5,76E-02 5.76E-02 5.76E-02 375 La-142 0.00E+00 1.75E-02 3.08E-02 3.08E-02 3.08E-02 3.08E-02 376 Ce-141 0.00E+00 8.95E-02 2.20E-01 2.23E-01 2.23E-01 2.23E-01 377 Ce-143 0,00E+00 8.01E-02 1.93E-01 1.95E 1.95E-01 1.95E-01 378 Ce-144 0.00E+00 7.36E-02 1.81E-01 1,83E-01 I

1.83E-01 1.83E-01 379 Pr-143 0.00E+00 3.22E-02 7.95E-02 8.04E-02 8,04E-02 8.04E-02 380 Nd-147 0.00E+00 1.42E-02 3,49E-02 3.53E-02 3.53E-02 3.53E-02 381 Np-239 0.'0E+00 1.04E+00 2.53E+00 2.55E+00 2.56E+00 2.56E+00 382 Pu-238 0.00E+00 2.18E-04 5.36E-04 5.42E-04 5.42E-04 5.43E-04 383 Pu-239 0,00E+00 2.38E-05 5.85E-05 5.92E-05 5.92E-05 5.92E-05 384 Pu-240 0.OOE+00 3.17B-05 7.80E-05 7.89E-05 7.89E-05 7.89E-05 385 Pu-241 0.00E+00 9.13E-03 2.25E-02 2.27E-02 2.27E-02 2.27E-02 386 Am-241 0.00E+00 4.57E-06 1.13E-05 1.14E-05 1.14E-05 1.14E-05 387 Cm-242 0.00E+00 1,06E-03 2.61E-03 2.64E-03 i

2.64E-03 2.64B-03 3888 Cm-244 0.00E+00 5.57E-05 1.37E-04 1.39E-04 1

1.39E-04 1.39E-04