L-PI-13-042, Independent Spent Fuel Storage Installation - 2012 Annual Radiological Environmental Monitoring Program (REMP) Report
ML13133A031 | |
Person / Time | |
---|---|
Site: | Prairie Island ![]() |
Issue date: | 05/03/2013 |
From: | Jeffery Lynch Northern States Power Co, Xcel Energy |
To: | Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation |
References | |
ISFSI TS 5.2, L-PI-13-042, TS 5.6.2 | |
Download: ML13133A031 (2) | |
Similar Documents at Prairie Island | |
---|---|
Category:Environmental Monitoring Report
MONTHYEARML23128A1092023-05-0808 May 2023
[Table view]Independent Spent Fuel Storage Installation - 2022 Annual Radiological Environmental Monitoring Program Report ML23128A0922023-05-0808 May 2023 2022 Annual Radioactive Effluent Report ML23053A1572023-02-16016 February 2023 Independent Spent Fuel Storage Installation - Independent Spent Fuel Storage Installation (ISFSI) Annual Effluent Report, January Through December 2022 ML22130A1472022-05-10010 May 2022 2021 Annual Radiological Environmental Monitoring Program Report ML22130A3882022-05-10010 May 2022 2021 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual ML22049B5442022-02-18018 February 2022 Independent Spent Fuel Storage Installation (ISFSI) Annual Effluent Report, January Through December 2021 ML21134A0052021-05-14014 May 2021 2020 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual ML21039A6392021-02-0808 February 2021 Independent Spent Fuel Storage Installation (ISFSI) Annual Effluent Report, January Through December 2020 ML20136A0162020-05-15015 May 2020 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual ML20049C5192020-02-18018 February 2020 Screenshots/Referenced Used in Environmental Assessment Prepared for the Proposed License Amendment for the Prairie Island Independent Spent Fuel Storage Installation (Dkt No. 72-10) ML18134A0122018-05-14014 May 2018 2017 Annual Radiological Environmental Monitoring Program Report ML17130A9692017-05-0808 May 2017 Submittal of 2016 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual ML17130A9542017-05-0808 May 2017 Independent Spent Fuel Storage Installation - 2016 Annual Radiological Environmental Monitoring Program Report L-PI-17-008, Independent Spent Fuel Storage Installation (ISFSI) Annual Effluent Report, January Through December 20162017-02-22022 February 2017 Independent Spent Fuel Storage Installation (ISFSI) Annual Effluent Report, January Through December 2016 L-PI-16-037, Transmittal of 2015 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual2016-05-0505 May 2016 Transmittal of 2015 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual L-PI-16-038, ISFSI - Transmittal of 2015 Annual Radiological Environmental Monitoring Program Report2016-05-0505 May 2016 ISFSI - Transmittal of 2015 Annual Radiological Environmental Monitoring Program Report L-PI-16-014, ISFSI - Annual Effluent Report, January Through December 20152016-02-26026 February 2016 ISFSI - Annual Effluent Report, January Through December 2015 L-PI-15-039, ISFSI - 2014 Annual Radioloqical Environmental Monitoring Program (REMP) Report2015-05-11011 May 2015 ISFSI - 2014 Annual Radioloqical Environmental Monitoring Program (REMP) Report L-PI-15-038, 2014 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM)2015-05-0505 May 2015 2014 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM) ML14175B1932014-05-0909 May 2014 Enclosure 2 - Annual Radioactive Effluent Report Supplemental Information, January 1, 2013 - December 31, 2013 L-PI-14-043, Independent Spent Fuel Storage Installation, 2013 Annual Radiological Environmental Monitoring Program (REMP) Report2013-12-31031 December 2013 Independent Spent Fuel Storage Installation, 2013 Annual Radiological Environmental Monitoring Program (REMP) Report L-PI-13-037, Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM)2013-05-0303 May 2013 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM) L-PI-13-042, Independent Spent Fuel Storage Installation - 2012 Annual Radiological Environmental Monitoring Program (REMP) Report2013-05-0303 May 2013 Independent Spent Fuel Storage Installation - 2012 Annual Radiological Environmental Monitoring Program (REMP) Report ML13133A2472012-12-31031 December 2012 Xcel Energy Corp Prairie Island Nuclear Generating Plant Annual Report to NRC, Radiological Environmental Monitoring Program January 1 to December 31, 2012 ML12135A2882012-05-11011 May 2012 Independent Spent Fuel Storage Installation - Submittal of 2011 Annual Radiological Environmental Monitoring Program (REMP) Report L-PI-11-040, Independent Spent - 2010 Annual Radiological Environmental Monitoring Program (REMP) Report2011-05-12012 May 2011 Independent Spent - 2010 Annual Radiological Environmental Monitoring Program (REMP) Report L-PI-11-036, 2010 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM)2011-05-12012 May 2011 2010 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM) L-PI-11-009, Independent Spent Fuel Storage Installation Annual Effluent Report, January Through December 20102011-02-24024 February 2011 Independent Spent Fuel Storage Installation Annual Effluent Report, January Through December 2010 ML1013803022010-05-12012 May 2010 Independent Spent Fuel Storage Installation, Submittal of 2009 Annual Radiological Environmental Monitoring Program Report L-PI-10-028, Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM)2010-05-12012 May 2010 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual (ODCM) L-PI-10-011, Independent Spent Fuel Storage Installation - Submittal of Annual Effluent Report, January Through December 20092010-02-25025 February 2010 Independent Spent Fuel Storage Installation - Submittal of Annual Effluent Report, January Through December 2009 L-PI-09-103, Corrections to the 2007 Annual Radiological Environmental Monitoring Program (REMP) Report and the 2007 Annual Radioactive Effluent Report2009-10-0707 October 2009 Corrections to the 2007 Annual Radiological Environmental Monitoring Program (REMP) Report and the 2007 Annual Radioactive Effluent Report L-PI-09-058, Submittal of 2008 Annual Radiological Environmental Monitoring Program (REMP) Report, Technical Specification) 5.6.2, Appendix a2009-05-13013 May 2009 Submittal of 2008 Annual Radiological Environmental Monitoring Program (REMP) Report, Technical Specification) 5.6.2, Appendix a L-PI-09-055, 2008 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual2009-05-12012 May 2009 2008 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual ML0833802242008-12-0303 December 2008 PINGP - SEIS Reference - NOAA Regional Climate Centers 2008e ML0834001502008-12-0202 December 2008 PINGP License Renewal: EPA Office of Solid Waste. Refer. 2008f L-PI-08-027, Nuclear Management Company, Inc. 2007 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual2008-05-13013 May 2008 Nuclear Management Company, Inc. 2007 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual L-PI-08-033, 2007 Annual Radiological Environmental Monitoring Program (REMP) Report2008-05-13013 May 2008 2007 Annual Radiological Environmental Monitoring Program (REMP) Report L-PI-07-033, 2006 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual2007-05-14014 May 2007 2006 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual L-PI-07-035, 2006 Annual Radiological Environmental Monitoring Program (REMP) Report2007-05-0707 May 2007 2006 Annual Radiological Environmental Monitoring Program (REMP) Report L-PI-06-037, Annual Radiological Environment Environmental Monitoring Program (REMP) Report2006-05-0606 May 2006 Annual Radiological Environment Environmental Monitoring Program (REMP) Report ML0612800402006-05-0505 May 2006 2005 Annual Radiological Environmental Monitoring Program (REMP) Report ML0613700962005-12-31031 December 2005 Off-Site Radiation Dose Assessment for January 01, 2005 - December 31, 2005 L-PI-05-046, Annual Radioactive Effluent Report and Offsite Dose Calculation Manual2005-05-16016 May 2005 Annual Radioactive Effluent Report and Offsite Dose Calculation Manual L-PI-05-043, SNM-2506 - 2004 Annual Radiological Environmental Monitoring Report2005-05-12012 May 2005 SNM-2506 - 2004 Annual Radiological Environmental Monitoring Report L-PI-04-061, Annual Radiological Environmental Monitoring Report2004-05-14014 May 2004 Annual Radiological Environmental Monitoring Report ML0414205042003-12-31031 December 2003 2003 Annual Radioactive Effluent Report for Prairie Island Nuclear Generating Plant Units 1 and 2 L-PI-03-051, 2002 Annual Radiological Environmental Monitoring Report for Prairie Island Nuclear Generating Plant2003-05-15015 May 2003 2002 Annual Radiological Environmental Monitoring Report for Prairie Island Nuclear Generating Plant ML0037146542000-05-0404 May 2000 Annual Radiological Environmental Monitoring Report 2023-05-08 Category:Letter type:L MONTHYEARL-PI-23-034, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System,2024-01-0202 January 2024
[Table view]Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System, L-PI-23-035, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report2023-12-20020 December 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report L-PI-23-033, Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 32023-12-0505 December 2023 Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 3 L-PI-23-025, License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 32023-09-28028 September 2023 License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 3 L-PI-23-023, Baffle Former Bolts Alternate Aging Management Strategy2023-09-11011 September 2023 Baffle Former Bolts Alternate Aging Management Strategy L-PI-23-018, License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT2023-07-14014 July 2023 License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT L-PI-23-006, License Amendment Request to Revise Technical Specification 3.7.8 Required Actions2023-06-22022 June 2023 License Amendment Request to Revise Technical Specification 3.7.8 Required Actions L-PI-23-016, 2022 10 CFR 50.46 LOCA Annual Report2023-06-14014 June 2023 2022 10 CFR 50.46 LOCA Annual Report L-PI-23-010, Annual Report of Individual Monitoring2023-04-27027 April 2023 Annual Report of Individual Monitoring L-PI-23-007, Supplement to Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR)2023-03-28028 March 2023 Supplement to Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR) L-PI-23-005, CFR 50.55a Requests Nos. 1-RR-5-15 and 2-RR-5-15, Proposed Use of Subsequent ASME Code Edition and Addenda in Accordance with 10 CFR 50.55a(g)(4)(iv)2023-03-0303 March 2023 CFR 50.55a Requests Nos. 1-RR-5-15 and 2-RR-5-15, Proposed Use of Subsequent ASME Code Edition and Addenda in Accordance with 10 CFR 50.55a(g)(4)(iv) L-PI-23-001, Day Steam Generator Tube Inspection Report2023-01-30030 January 2023 Day Steam Generator Tube Inspection Report L-PI-22-047, Resubmittal of Prairie Island Nuclear Generating Plant (PINGP) 2018 Unit 1 180-Day Steam Generator Tube Inspection Report2022-12-21021 December 2022 Resubmittal of Prairie Island Nuclear Generating Plant (PINGP) 2018 Unit 1 180-Day Steam Generator Tube Inspection Report L-PI-22-020, Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR)2022-12-0202 December 2022 Application to Revise Technical Specification Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR) L-PI-22-040, Supplement to Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2022-10-0606 October 2022 Supplement to Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections L-PI-22-037, Updated Approach for Prairie Island Unit 1 and Unit 2 Baffle Former Bolts2022-09-20020 September 2022 Updated Approach for Prairie Island Unit 1 and Unit 2 Baffle Former Bolts L-PI-22-032, CFR 50.46 LOCA Annual Report2022-06-16016 June 2022 CFR 50.46 LOCA Annual Report L-PI-22-033, Response to Request for Additional Information Prairie Island Nuclear Generating Plant, Units 1 and 2, Amendment to Adopt 24-Month Operating Cycles2022-06-10010 June 2022 Response to Request for Additional Information Prairie Island Nuclear Generating Plant, Units 1 and 2, Amendment to Adopt 24-Month Operating Cycles L-PI-22-003, Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2022-06-0707 June 2022 Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections L-PI-22-024, Supplement to Application for License Amendment to Implement 24-Month Operating Cycle2022-03-0707 March 2022 Supplement to Application for License Amendment to Implement 24-Month Operating Cycle L-PI-21-047, Response to Request for Additional Information 24-Month Cycle Amendment Prairie Island Nuclear Generating Plant, Units 1 and 22021-12-0707 December 2021 Response to Request for Additional Information 24-Month Cycle Amendment Prairie Island Nuclear Generating Plant, Units 1 and 2 L-PI-21-045, Response to Request for Additional Information Cooling Water System License Amendment Request2021-11-0404 November 2021 Response to Request for Additional Information Cooling Water System License Amendment Request L-PI-21-029, Exigent License Amendment Request to Revise Technical Specification 3.7.8 to Allow a One-Time Extension of the Completion Time of Required Action B.12021-10-0707 October 2021 Exigent License Amendment Request to Revise Technical Specification 3.7.8 to Allow a One-Time Extension of the Completion Time of Required Action B.1 L-PI-21-006, License Amendment Request to Revise Technical Specification 3.3.1, Reactor Trip System (RTS) Instrumentation, to Incorporate Installed Bypass Test Capability for the Power Range RTS Functions2021-10-0202 October 2021 License Amendment Request to Revise Technical Specification 3.3.1, Reactor Trip System (RTS) Instrumentation, to Incorporate Installed Bypass Test Capability for the Power Range RTS Functions L-PI-21-032, Response to Request for Additional Information Amendment Request to Adopt TSTF-471 and 571-T for Prairie Island2021-09-30030 September 2021 Response to Request for Additional Information Amendment Request to Adopt TSTF-471 and 571-T for Prairie Island L-PI-21-016, Application for License Amendment to Implement 24-Month Operating Cycle2021-08-0606 August 2021 Application for License Amendment to Implement 24-Month Operating Cycle L-PI-21-027, 2020 10 CFR 50.46 LOCA Annual Report2021-06-28028 June 2021 2020 10 CFR 50.46 LOCA Annual Report L-PI-21-023, Independent Spent Fuel Storage Installation - 2020 Annual Radiological Environmental Monitoring Program Report2021-05-14014 May 2021 Independent Spent Fuel Storage Installation - 2020 Annual Radiological Environmental Monitoring Program Report L-PI-21-007, Application to Revise Technical Specifications to Adopt TSTF-471, Eliminate Use of the Term Core Alterations in Actions and Notes2021-04-19019 April 2021 Application to Revise Technical Specifications to Adopt TSTF-471, Eliminate Use of the Term Core Alterations in Actions and Notes L-PI-20-050, Request for a One-Time Exemption from 10 CFR 50, Appendix E, Biennial Emergency Preparedness Exercise Requirements, Due to COVID-19 Pandemic2020-10-0707 October 2020 Request for a One-Time Exemption from 10 CFR 50, Appendix E, Biennial Emergency Preparedness Exercise Requirements, Due to COVID-19 Pandemic L-PI-20-051, Supplement to Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements2020-09-28028 September 2020 Supplement to Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements L-PI-20-026, Response to Request for Additional Information: License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiativ2020-09-0101 September 2020 Response to Request for Additional Information: License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4 L-PI-20-035, = Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule2020-07-28028 July 2020 = Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule L-PI-20-023, Independent Spent Fuel Storage Installation, Response to Request for Additional Information: License Amendment Request to Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI)2020-06-10010 June 2020 Independent Spent Fuel Storage Installation, Response to Request for Additional Information: License Amendment Request to Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI) L-PI-20-014, Supplement to License Amendment Request: Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI2020-04-29029 April 2020 Supplement to License Amendment Request: Expand the Storage Capacity of the Independent Spent Fuel Storage Installation (ISFSI L-PI-20-004, License Amendment Request to Revise Technical Specifications (TS) to Remove Note I from Limiting Condition for Operating (LCO) 3.4.12 and LCO 3.4.132020-03-30030 March 2020 License Amendment Request to Revise Technical Specifications (TS) to Remove Note I from Limiting Condition for Operating (LCO) 3.4.12 and LCO 3.4.13 L-PI-20-001, License Amendment Request to Address Issues Identified in Westinghouse Nuclear Safety Advisory Letter NSAL-09-5, Revision 1, and NSAL-15-12020-01-29029 January 2020 License Amendment Request to Address Issues Identified in Westinghouse Nuclear Safety Advisory Letter NSAL-09-5, Revision 1, and NSAL-15-1 L-PI-19-041, Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements2019-12-23023 December 2019 Application to Revise Technical Specifications to Adopt TSTF-547, Clarification of Rod Position Requirements L-PI-19-031, License Amendment Request: Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2019-12-16016 December 2019 License Amendment Request: Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b L-PI-19-040, License Amendment Request: Revise Technical Specification 5.5.14 to Permanently Extend Containment Leakage Rate Test Frequency2019-10-0707 October 2019 License Amendment Request: Revise Technical Specification 5.5.14 to Permanently Extend Containment Leakage Rate Test Frequency L-PI-19-038, Submittal of Revised Pressure and Temperature Limits Report2019-09-19019 September 2019 Submittal of Revised Pressure and Temperature Limits Report L-PI-19-037, Response to Request for Additional Information: 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals2019-09-16016 September 2019 Response to Request for Additional Information: 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals L-PI-19-025, Request to Approve Site-Specific Probabilistic Risk Assessment (PRA) Model for Flowserve N-Seal Abeyance Seal and Dynamic Testing for the Prairie Island Nuclear Generating Plant (PINGP)2019-08-27027 August 2019 Request to Approve Site-Specific Probabilistic Risk Assessment (PRA) Model for Flowserve N-Seal Abeyance Seal and Dynamic Testing for the Prairie Island Nuclear Generating Plant (PINGP) L-PI-19-029, Supplement to Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components For...2019-08-0505 August 2019 Supplement to Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components For... L-PI-19-002, 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals for Prairie Island, Unit 1 and Unit 22019-06-13013 June 2019 10 CFR 50.55a Requests Nos. 1-RR-5-10 and 2-RR-5-10, Proposed Alternative to Reactor Vessel Inservice Inspection (ISI) Intervals for Prairie Island, Unit 1 and Unit 2 L-PI-19-014, Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2019-04-29029 April 2019 Response to Request for Additional Information: Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-PI-19-003, Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule for Prairie Island Nuclear Generating Plant (PINGP)2019-02-0404 February 2019 Request for Revision to Reactor Vessel Material Surveillance Capsule Removal Schedule for Prairie Island Nuclear Generating Plant (PINGP) L-PI-19-006, Emergency License Amendment Request Regarding One-Time Extension for Technical Specification Completion Time Requirements2019-01-29029 January 2019 Emergency License Amendment Request Regarding One-Time Extension for Technical Specification Completion Time Requirements L-PI-19-005, Online Reference Portal for NRC Review of License Amendment Request to Implement 10 CFR 50.692019-01-15015 January 2019 Online Reference Portal for NRC Review of License Amendment Request to Implement 10 CFR 50.69 L-PI-18-063, Response to Request for Additional Information: Revise License Condition Associated with Implementation of NFPA 8052018-12-0606 December 2018 Response to Request for Additional Information: Revise License Condition Associated with Implementation of NFPA 805 2024-01-02 |
Text
XcelEnergy L-PI-13-042 MAY 0 3 2013 TS 5.6.2 ISFSI TS 5.2 U S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Prairie Island Nuclear Generating Plant Prairie Island Independent Spent Units 1 and 2 Fuel Storage Installation Dockets 50-282 and 50-306 Docket 72-10 Renewed License Nos. DPR-42 and DPR-60 Materials License No. SNM-2506 2012 Annual Radiological Environmental Monitoring Program (REMP) Report Pursuant to Prairie Island Nuclear Generating Plant (PINGP) Technical Specification (TS) 5.6.2, Appendix A, to Renewed Operating Licenses DPR-42 and DPR-60, and Prairie Island Independent Spent Fuel Storage Installation Technical Specification (ISFSI TS) 5.2, Appendix A, to Materials License SNM-2506, Northern States Power Company, a Minnesota corporation, doing business as Xcel Energy (hereafter "NSPM"),
submits one copy of the Annual Radiological Environmental Monitoring Program report for the period January 1, 2012 through December 31, 2012 as Enclosure 1.
Summary of Commitments This letter contains no new commitments and no revisions to existing commitments.
James; .Lyn ch Site Vice President, Prairie Island Nuclear Generating Plant Northern States Power Company - Minnesota Enclosure cc: Regional Administrator, USNRC, Region III Project Manager, Prairie Island Nuclear Generating Plant, USNRC, NRR NRC Resident Inspector, Prairie Island Nuclear Generating Plant Billy Dickson, USNRC, Region III Director of NMSS, USNRC Department of Health, State of Minnesota PI Dakota Community Environmental Coordinator 1717 Wakonade Drive East
- Welch, Minnesota 55089-9642 Telephone: 651.388.1121 >" J.- .
ENCLOSURE I C, Annual Report to the United States Nuclear Regulatory Commission Radiological Environmental Monitoring Program January 1 to December 31, 2012 73 pages follow