MONTHYEARML16047A2722016-02-10010 February 2016 License Amendment Request: Revise Technical Specification 5.5.11 to Provide a Permanent Extension of the Integrated Leakage Rate (Type a) Test Frequency from Ten to Fifteen Years Project stage: Other ML16082A3712016-03-22022 March 2016 NRR E-mail Capture - Monticello Nuclear Generating Plant - NRC Staff'S Acceptance Review Results for February 10, 2016 License Amendment Request Related to Integrated Leak Rate Type a Testing Project stage: Acceptance Review ML16256A0042016-09-0909 September 2016 NRR E-mail Capture - Request for Additional Information Monticello License Amendment Request for ILRT Extension Project stage: RAI L-MT-16-044, Response to Request for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval2016-10-10010 October 2016 Response to Request for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval Project stage: Response to RAI ML16323A2422016-11-18018 November 2016 NRR E-mail Capture - Monticello ILRT Extension Amendment Request for Additional Information Project stage: RAI L-MT-16-062, Part 1 Response to Probabilistic Risk Assessment Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval2016-12-16016 December 2016 Part 1 Response to Probabilistic Risk Assessment Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval Project stage: Request L-MT-17-002, Part 2 Response to Probabilistic Risk Assessment (PRA) Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50Appendix J Containment Type a Test Interval2017-01-31031 January 2017 Part 2 Response to Probabilistic Risk Assessment (PRA) Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50Appendix J Containment Type a Test Interval Project stage: Request L-MT-17-007, Part 3 Response to Probabilistic Risk Assessment (PRA) Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval2017-02-0707 February 2017 Part 3 Response to Probabilistic Risk Assessment (PRA) Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval Project stage: Request ML17033A0452017-02-0909 February 2017 Summary of the Audit to Support the Review of the Monticello Nuclear Generating Plant License Amendment Request to Extended the Integrated Leak Rate Test Frequency Project stage: Approval L-MT-17-011, Supplement to License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval2017-02-16016 February 2017 Supplement to License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval Project stage: Supplement ML17086A0602017-03-27027 March 2017 NRR E-mail Capture - Request for Additional Information Monticello Nuclear Generating Plant Integrated Leak Rate Test Interval Extension Request Project stage: RAI L-MT-17-022, Response to Second Round PRA Related RAIs for the License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval2017-03-29029 March 2017 Response to Second Round PRA Related RAIs for the License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type a Test Interval Project stage: Request ML17090A2442017-04-0606 April 2017 Summary of February 28, 2017, Meeting with Northern States Power Company, Doing Business as Xcel Energy, on the Integrated Leak Rate Test License Amendment Request for Monticello Nuclear Generating Plant CAC No. MF7359) Project stage: Meeting ML17103A2352017-04-25025 April 2017 Issuance of Amendment Technical Specification 5.5.11 Primary Containment Leakage Rate Testing Program Project stage: Approval 2017-01-31
[Table View] |
|
---|
Category:Letter type:L
MONTHYEARL-MT-24-022, – Preparation and Scheduling of Operator Licensing Examinations2024-07-0909 July 2024 – Preparation and Scheduling of Operator Licensing Examinations L-MT-24-019, Submittal of ASME Section XI, Section IWB-3720 Analytical Evaluation in Accordance with 10 CFR 50.55a(b)(2)(xliii)2024-06-10010 June 2024 Submittal of ASME Section XI, Section IWB-3720 Analytical Evaluation in Accordance with 10 CFR 50.55a(b)(2)(xliii) L-MT-24-017, Response to Request for Additional Information Regarding License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.6 (EPID-L-2023-LLA-01602024-06-0404 June 2024 Response to Request for Additional Information Regarding License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.6 (EPID-L-2023-LLA-0160 L-MT-24-015, Response to Request for Additional Information - Alternative Request VR-09 for OMN-172024-05-16016 May 2024 Response to Request for Additional Information - Alternative Request VR-09 for OMN-17 L-MT-24-013, 2023 Annual Radiological Environmental Operating Report2024-05-14014 May 2024 2023 Annual Radiological Environmental Operating Report L-MT-24-016, 2023 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP)2024-05-0808 May 2024 2023 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP) L-MT-24-002, Submittal of Revision 41 to the Updated Safety Analysis Report2024-04-17017 April 2024 Submittal of Revision 41 to the Updated Safety Analysis Report L-MT-24-004, Submittal of 10 CFR 72.48 Report for Monticello Nuclear Generating Plant (MNGP)2024-04-17017 April 2024 Submittal of 10 CFR 72.48 Report for Monticello Nuclear Generating Plant (MNGP) L-MT-24-006, Subsequent License Renewal Application Annual Update 1 and Supplement 92024-02-29029 February 2024 Subsequent License Renewal Application Annual Update 1 and Supplement 9 L-MT-24-007, Response to NRC Request for Additional Information on Proposed Inservice Inspection Alternative RR-002 for the Sixth Ten-Year ISI Interval2024-02-15015 February 2024 Response to NRC Request for Additional Information on Proposed Inservice Inspection Alternative RR-002 for the Sixth Ten-Year ISI Interval L-MT-24-001, 10 CFR 50.55a Request RR-017 - Inservice Inspection (ISI) Impracticality in Accordance with 10 CFR 50.55a(g)(5)(iii) During the Fifth Ten-Year Interval2024-01-30030 January 2024 10 CFR 50.55a Request RR-017 - Inservice Inspection (ISI) Impracticality in Accordance with 10 CFR 50.55a(g)(5)(iii) During the Fifth Ten-Year Interval L-MT-23-054, Subsequent License Renewal Application Supplement 82024-01-11011 January 2024 Subsequent License Renewal Application Supplement 8 L-MT-23-047, License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data2023-12-29029 December 2023 License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data L-MT-23-056, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 22023-12-18018 December 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 2 L-MT-23-042, 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462023-12-11011 December 2023 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-23-052, Subsequent License Renewal Application Supplement 72023-11-30030 November 2023 Subsequent License Renewal Application Supplement 7 L-MT-23-051, Update to the Technical Specification Bases2023-11-28028 November 2023 Update to the Technical Specification Bases L-MT-23-049, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 12023-11-21021 November 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 L-MT-23-043, 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-092023-11-13013 November 2023 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-09 L-MT-23-038, License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.62023-11-10010 November 2023 License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.6 L-MT-23-046, Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 12023-11-0909 November 2023 Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 1 L-MT-23-041, Subsequent License Renewal Application Response to Request for Confirmation of Information Set 22023-10-0303 October 2023 Subsequent License Renewal Application Response to Request for Confirmation of Information Set 2 L-MT-23-037, Subsequent License Renewal Application Response to Request for Additional Information Set 32023-09-22022 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 3 L-MT-23-036, Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 62023-09-0505 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 6 L-MT-23-035, Subsequent License Renewal Application Supplement 52023-08-28028 August 2023 Subsequent License Renewal Application Supplement 5 L-MT-23-034, Subsequent License Renewal Application Response to Request for Additional Information Set 12023-08-15015 August 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 1 L-MT-23-032, 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-112023-07-31031 July 2023 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-11 L-MT-23-028, 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report2023-07-31031 July 2023 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report L-MT-23-031, Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 12023-07-18018 July 2023 Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 1 L-MT-23-030, Subsequent License Renewal Application Supplement 32023-07-0404 July 2023 Subsequent License Renewal Application Supplement 3 L-MT-23-025, Subsequent License Renewal Application Supplement 22023-06-26026 June 2023 Subsequent License Renewal Application Supplement 2 L-MT-23-020, Submittal of 2022 Annual Radioactive Effluent Release Report2023-05-10010 May 2023 Submittal of 2022 Annual Radioactive Effluent Release Report L-MT-23-019, Submittal of 2022 Annual Radiological Environmental Operating Report2023-05-10010 May 2023 Submittal of 2022 Annual Radiological Environmental Operating Report L-MT-23-021, Core Operating Limits Report (COLR) for the Monticello Nuclear Generating Plant for Cycle 322023-05-0202 May 2023 Core Operating Limits Report (COLR) for the Monticello Nuclear Generating Plant for Cycle 32 L-MT-23-017, 2022 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP)2023-04-18018 April 2023 2022 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP) L-MT-23-010, Subsequent License Renewal Application Supplement 12023-04-0303 April 2023 Subsequent License Renewal Application Supplement 1 L-MT-23-013, Core Operating Limits Report (COLR) for Cycle 31, Revision 32023-03-28028 March 2023 Core Operating Limits Report (COLR) for Cycle 31, Revision 3 L-MT-23-012, Core Operating Limits Report (COLR) for Monticello Nuclear Generating Plant Cycle 31, Revision 22023-03-17017 March 2023 Core Operating Limits Report (COLR) for Monticello Nuclear Generating Plant Cycle 31, Revision 2 L-MT-23-008, 10CFR50.55a Request to Use Later Edition of ASME Section XI for ISI Code of Record (RR-003)2023-02-0707 February 2023 10CFR50.55a Request to Use Later Edition of ASME Section XI for ISI Code of Record (RR-003) L-MT-23-004, CFR 50.55a Request RR-001, Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI for the Monticello Third Interval Containment Inservice Inspection Program2023-01-23023 January 2023 CFR 50.55a Request RR-001, Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI for the Monticello Third Interval Containment Inservice Inspection Program L-MT-23-005, Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088)2023-01-0606 January 2023 Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088) L-MT-22-049, Industry Groundwater Protection Initiative Special Report2022-12-15015 December 2022 Industry Groundwater Protection Initiative Special Report L-MT-22-052, L-MT-22-052 Monticello Nuclear Generating Plant 10 CFR 50.55a Request No. Pr 08, Request for HPCI Pump Quarterly Alternative2022-12-15015 December 2022 L-MT-22-052 Monticello Nuclear Generating Plant 10 CFR 50.55a Request No. Pr 08, Request for HPCI Pump Quarterly Alternative L-MT-22-046, 2022 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462022-12-13013 December 2022 2022 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-22-048, Update to the Monticello Technical Specification Bases2022-11-28028 November 2022 Update to the Monticello Technical Specification Bases L-MT-22-047, Withdrawal of Request for Relief from ASME OM Code for the Sixth Inservice Testing Interval2022-11-10010 November 2022 Withdrawal of Request for Relief from ASME OM Code for the Sixth Inservice Testing Interval L-MT-22-045, Letter Submitting Post-Exam Package2022-11-0404 November 2022 Letter Submitting Post-Exam Package L-MT-22-030, Sixth Interval Inservice Testing (1ST) Plan2022-09-0606 September 2022 Sixth Interval Inservice Testing (1ST) Plan L-MT-22-037, Supplement to 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval, Alternative VR-10, Excess Flow Check Valve Testing Frequency2022-08-29029 August 2022 Supplement to 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval, Alternative VR-10, Excess Flow Check Valve Testing Frequency L-MT-22-007, Response to Request for Additional Information for the Monticello Nuclear Generating Plant Alternative Request VR-08 (EPID: L-MT-22-007)2022-07-22022 July 2022 Response to Request for Additional Information for the Monticello Nuclear Generating Plant Alternative Request VR-08 (EPID: L-MT-22-007) 2024-07-09
[Table view] |
Text
2807 West County Road 75 Monticello, MN 55362 (l Xcel Energy*
RES P 0 N SIBLE BY NATURE 800.895.4999 xcelenergy.com February 16, 2017 L-MT-17-011 10 CFR 50.90 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Monticello Nuclear Generating Plant Docket No. 50-263 Renewed Facility Operating License No. DPR-22 Supplement to License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type A Test Interval (CAC No. MF7359)
References:
- 1) NSPM (P. Gardner) to NRC, "License Amendment Request: Revise Technical Specification 5.5.11 to Provide a Permanent Extension of the Integrated Leakage Rate (Type A) Test Frequency from Ten to Fifteen Years," (L-MT-16-001), dated February 10, 2016 (ADAMS Accession No. ML16047A272 and ML16047A273)
- 2) NRC (R. Kuntz) to NSPM (R. Loeffler), "Request for Additional Information RE: Monticello license amendment request for ILRT extension (CAC MF7359)," dated September 9, 2016 (ADAMS Accession No. ML16256A004)
- 3) NSPM (P. Gardner) to NRC, "Response to Request for Additional Information:
License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type A Test Interval (CAC No. MF7359)," (L-MT-16-044), dated October 10, 2016 (ADAMS Accession No. ML16284A015)
- 4) NRC (R. Kuntz) to NSPM (R. Loeffler), "Monticello ILRT extension amendment Request for additional information (CAC No. MF7359)," dated November 18, 2016 (ADAMS Accession No. ML16323A242)
- 5) NSPM (P. Gardner) to NRC, "Part 1 Response to Probabilistic Risk Assessment (PRA) Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type A Test Interval (CAC No. MF7359)"
(L-MT-16-062), dated December 16, 2016 (ADAMS Accession No. ML16355A183)
L-MT-17-011 Page 2 of 3
- 6) NSPM (P. Gardner) to NRC, "Part 2 Response to Probabilistic Risk Assessment (PRA) Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type A Test Interval (CAC No. MF7359)"
(L-MT-17-002), dated January 31,2017
- 7) NSPM (P. Gardner) to NRC, "Part 3 Response to Probabilistic Risk Assessment (PRA) Related Requests for Additional Information: License Amendment Request for a Permanent Extension of the 10 CFR 50 Appendix J Containment Type A Test Interval (CAC No. MF7359)"
(L-MT-17-007), dated February 7, 2017 On February 10, 2016, the Northern States Power Company, a Minnesota Corporation (NSPM), doing business as Xcel Energy, submitted a license amendment request (LAR) proposing a change the Technical Specifications (TS) for the Monticello Nuclear Generating Plant (MNGP). The proposed change is to permanently revise the frequency specified in Specification 5.5.11 "Primary Containment Leakage Rate Testing Program," to increase the containment integrated leakage rate test (ILRT) program Type A test interval from 10 years to 15 years (Reference 1).
It was discovered on February 10, 2017, that one Fact and Observation (F&O) from the March 2015 Fire PRA Peer Review had not been included in Appendix A.3 of the PRA calculation submitted as Enclosure 2 of the 15-Year ILRT LAR (Reference 1). It was identified that F&O 1-5 <1> (a "Suggestion" F&O) had inadvertently been included instead of F&O 4-35 (a "Finding" F&O). F&O 4-35 concerns the apportionment of the ignition frequency of the main control board (MCB) to individual fire scenarios based on the number of cables. A copy of F&O 4-35 is attached behind this letter. Note that F&O 4-35 is closed and there is no impact on the ILRT extension license amendment or associated RAI responses (References 2-7).
This omission error has been entered into the MNGP Corrective Action Program. A review of all Internal Event, Fire and Focused Scope Fire Peer Review findings was conducted to assure that with this submission they have now all been provided to the NRC.
- 1. F&O 1-5 involves a labeling mismatch that was corrected prior to submittal of the LAR (PRA calculation, page 118).
L-MT-17-011 Page 3 of 3 Summary of Commitments This letter makes no new commitments and no revisions to existing commitments.
I declare under penalty of perjury, that the foregoing is true and correct.
Executed on February!.-'.__, 2017.
Peter A. Gardner Site Vice President, Monticello Nuclear Generating Plant Northern States Power Company- Minnesota Appendix: Fact and Observation 4-35 cc: Administrator, Region Ill, US NRC Project Manager, Monticello Nuclear Generating Plant, US NRC Resident Inspector, Monticello Nuclear Generating Plant, US NRC State of Minnesota
APPENDIX MONTICELLO NUCLEAR GENERATING PLANT SUPPLEMENT TO LICENSE AMENDMENT REQUEST FOR A PERMANENT EXTENSION OF THE 10 CFR 50 APPENDIX J CONTAINMENT TYPE A TEST INTERVAL FACT AND OBSERVATION 4-35 (1 page follows)
L-MT-17-011 Appendix 1 Page 1 of 1 Facts and Observations (F&Os)
Change Number: MT-15-0080 F&O Number: 4-35 Associated SR(s): FSS-82 Detailed Problem
Description:
The Main Control Room Analysis Notebook 016015-RPT-07 apportions the ignition frequency of the main control board (MCB) to individual scenarios based on the number of cables. PRA FAQ 14-0008 provides details for apportioning of the MCB ignition frequency if Appendix Lis recalculated.
Proposed Solution: Remove the ignition frequency apportioning method and assign the entire MCB frequency to each scenario. Alternatively, provide technical justification for the apportioning of the MCB ignition frequency by cables or other method.
Basis for Significance: Appendix L is not utilized in the Main Control Room (MCR) analysis and ignition frequency should not be apportioned. Additionally, the number of cables may not be an appropriate method as cables could be routed through a MCB panel and not a termination point, therefore, the number of cables could be inaccurate.
Actual Solution: The methodology used in the Main Control Room Analysis Notebook 016015-RPT-07 is appropriate because the frequency is apportioned based on the density of cables and thus the concentration of sources (e.g., connections, switches) that are more likely to cause a fire. In addition, the methodology that has been implemented does not double count credit for the non-suppression probability for scenarios where control room abandonment is credited. The documentation provided in the Main Control Room Analysis Notebook gives a comparison to the approach recommended in NUREG/CR-6850, Appendix L. This comparison shows that the method used in the Monticello Fire PRA calculates a higher likelihood for the different fire scenario sequences modeled. The approach has the advantage of fully accounting for the MCB frequency and not double count non suppression probability credit when the control room abandonment is credited.
Impact on ILRT Extension: The F&O is closed, and there is no impact on the ILRT Extension Analysis.