ACCELEEATED DIA21BUTJON DEMONS'ZION SYSTEM REGULATORY INFORMATION DISTRIBUTXON SYSTEM (RIDS)

ACCESSION NBR:8805190020 DOC.DATE: 88/05/12 NOTARXZED: NO FACXL:50-389 St. Lucie Plant, Unit 2, Florida Power

& Light Co.

AUTH.NAME AUTHOR AFFILIATION

'ONWAY,W.F.

Florida Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Responds to NRC 880405 second request 'kr addi info re ASME Code relief requests for safety-related'umps.

DISTRIBUTION CODE:

A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal:

General Distribution NOTES DOCKET,C 05000389

'1R

'ECIPIENT" ID CODE/NAME PD2-2 LA TOURIGNY,E INTERNAL: ACRS NRR/DEST/ADS 7E NRR/DEST/ESB 8D NRR/DEST/RSB 8E NRR/PMAS/ILRB12 OGC 15-B-18 RES/DE/EIB EXTERNAL: LPDR NSIC COPIES LTTR ENCL 1

0 1

1 RECIPIENT ID CODE/NAME PD2-2 PD ARM/DAF/LFMB NRR/DEST/CEB 8H NRR/DEST/MTB 9H NRR/DOEA/TSB 11 NUDQG~%

RACT FIL 01 NRC PDR COPIES

'TTR ENCL' 5

1

~ 0 1

1 1

1 1

1 1

1 1

1 1

1 A

+ra.&iAb T< 4g F> (es,

'A,I D

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 28 ENCL 25

P.

BOX 14000, JUNO BEACH, FL 3340B-0420

+Ml/y

/fIA MAY, 1 2 1988 L-88-223 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Re:

St. Lucie Unit 2 Docket No. 50-389 2nd Request for Additional Information ASME Code Relief Re uests for Various Safet -Related Pum s The purpose of this letter is to provide the additional information requested in your April 5, 1988 letter, "Request for Additional Information ASME Code Relief Requests for Various Safety-Related Pumps" (TAC No.

64819).

Attached is the additional information.

Should there be further questions, please contact us.

Very truly yours, W.

Conw Senior Vi e President Nuclear WFC/MSD/gp Attachment cc:

Dr. J.

Nelson Grace, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant MSD2nd. RAI SS05190020 SS0512 PDR ADOCK 050003S9 P

DCD an FPL Group company

pi

INFORMATION PROVIDED i,

D~rawin s

All drawings are the latest revision per the "St.

Lucie-Unit i

Mechanical Drawing Index" dated 4/1/88 or the "St.

Lucie-Unit 2 Drawing list" dated 3/31/88.

A.

The following P&IDs are attached as requested:

~grawin No.

2998-G-079 2998-G-079 2998-G-079 2998-G-079 2998-G-079 2998-G-079 2998-G-080 2998-G-080 2998-G-086-2998-G-088 8770-G-086 2998-G-078 110 (originally E-13172-310-110)

'5 16 16 16 13 15 Main Steam Main Steam Extraction Steam Extraction Steam Auxiliary Steam Air Evacuation 18 Feedwater 15 16 18 Feedwater Diesel Fuel Oil (Unit 2)

Containment Spray 17 Diesel Fuel Oil (Unit 1)

Reactor Coolant 2998-G-078 121 (originally E-13172-310-121) 2 Chemical and Volume Control 2998-G-078 122 (original 1 y E-13172-310-122) 2998-G-078 130 (originally E-13172-310-130) 2998-G-078 131 (original 1 y E-13172-310-131) 1 Chemical and Volume Control 2

Safety Injection Safety Injection

B.

The following piping isometrics requested are attached for the identified lines-Pi e Isometric No.

Sht.

No.

Rev.

No.

Line No.

~Sstem 2998-G-125 SI-N-13 14 I-3"- SI-156

HPSI, LPSI Common Hiniflow Line (B Pumps) 2998-G-125 2998-G-125 2998-G-125 2998-G-125 2998-C-124 S I -N-12 21 SI-N-12 21 CS-K-3 21 CS-K-9 12 BF-3 I-3"-SI-200 6"-CS-500 6"-CS-500 6"-CS-500 I-2"-BF-47
HPSI, LPSI Common Hiniflow Line (A Pumps)

LPSI, Containment Spray Recirc.

Line LPSI, Containment Spray Recirc.

Line LPSI, Containment Spray Recirc.

AFW Pump Common Hiniflow Line

2.

Vendor Recommended Minimum Allowable Flow Rates Pump Vendor Minimum Allowables Flow Rate*

Source HPSI Bingham-Willamette 4

30 GPM Instruction Manual ¹ 2998-6738 LPSI Ingersoll-Rand 100 GPH Instruction Manual ¹ 2998-5946 Containment Spray Ingersoll-Rand 150 GPH Instruction Manual ¹ 2998-4509 Auxiliary Feedwater (A&B - motor driven)

Ingersoll-Rand 50 GPH Instruction Manual ¹ 2998-6963 Auxiliary Feedwater (C-steam driven)

Ingersoll-Rand 70 GPH Instruction Manual ¹ 2998-6964 The value given for the minimum allowable flow rate of each

pump, according to the vendors, is that flow required to prevent the pump from overheating.

To prevent overheating and possible pump

seizure, regardless of system.
demand, a recirculation line around the pump (or bypass line) is provided in the piping system.

This serves to insure that a flow rate (generally called "minimum flow", "bypass flow," or "minimum continuous flow"), is maintained thru the

pump, in the event that the discharge valving is completely closed or there is no demand by the system (pump remaining at shut-off, i.e.,

zero flow).

This minimum flow was calculated by. each vendor to prevent harmful

. temperature rise in the pump due to the energy (horsepower) being delivered to the water by the pump.

The heat, generated by the pump, can be rejected by the cooling action of the vessel receiving "minimum flow" via the bypass l,ine; thus the temperature differential between suction and discharge connections can be held constant within acceptable limits, consistent with other system parameters.