ML17221A763

From kanterella
Jump to navigation Jump to search
Responds to NRC 880405 Second Request for Addl Info Re ASME Code Relief Requests for safety-related pumps.W/21 Oversize Drawings
Date released: 01/25/2018 Download: ML17221A763


Flow Diagram Main Steam System SH.NO.1. Sheet 1 of 6
ML17222A238
Person / Time
Site: Saint Lucie 
Issue date: 08/09/1985
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17222A238 (1)
Flow Diagram Main Steam SYSTEM-SH.NO.2. Sheet 2 of 6
ML17222A237
Person / Time
Site: Saint Lucie 
Issue date: 09/30/1986
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17222A237 (1)
Flow Diagram Extraction Steam SYSTEM-SH.NO.1. Sheet 3 of 6
ML17221A782
Person / Time
Site: Saint Lucie 
Issue date: 09/30/1986
From:
EBASCO SERVICES, INC.
To:
References
Download: ML17221A782 (1)
Flow Diagram Extraction Steam SYSTEM-SH.NO.2. Sheet 4 of 6
ML17221A781
Person / Time
Site: Saint Lucie 
Issue date: 09/30/1986
From:
EBASCO SERVICES, INC.
To:
References
Download: ML17221A781 (1)
Flow Diagram Auxiliary Steam System. Sheet 5 of 6
ML17221A780
Person / Time
Site: Saint Lucie 
Issue date: 08/09/1985
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A780 (1)
Flow Diagram Air Evacuation System. Sheet 6 of 6
ML17221A779
Person / Time
Site: Saint Lucie 
Issue date: 08/28/1987
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A779 (1)
Flow Diagram & Condensate System. Sheet 1 of 2
ML17221A778
Person / Time
Site: Saint Lucie 
Issue date: 08/20/1987
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A778 (1)
Flow Diagram Feedwater & Condensate System. Sheet 2 of 2
ML17221A777
Person / Time
Site: Saint Lucie 
Issue date: 02/04/1988
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A777 (1)
Flow Diagram Miscellaneous System.
ML17221A776
Person / Time
Site: Saint Lucie 
Issue date: 02/02/1988
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A776 (1)
Flow Diagram Containment Spray & Refueling Water Systems.
ML17221A775
Person / Time
Site: Saint Lucie 
Issue date: 08/20/1987
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A775 (1)
Flow Diagram Miscellaneous Systems Sheet 1.
ML17221A774
Person / Time
Site: Saint Lucie 
Issue date: 03/24/1987
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A774 (1)
Flow Diagram Reactor Coolant System (Sheet 4). Sheet 110
ML17221A773
Person / Time
Site: Saint Lucie 
Issue date: 09/13/1985
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A773 (1)
Flow Diagram Chemical & Volume Control System (Sheet 2). Sheet 121
ML17221A772
Person / Time
Site: Saint Lucie 
Issue date: 04/12/1985
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A772 (1)
Flow Diagram Chemical & Volume Control System (Sheet 3). Sheet 122
ML17221A771
Person / Time
Site: Saint Lucie 
Issue date: 09/04/1986
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A771 (1)
Flow Diagram Safety Injection System (Sheet 1). Sheet 130
ML17221A770
Person / Time
Site: Saint Lucie 
Issue date: 12/22/1987
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A770 (1)
Flow Diagram Safety Injection System (Sheet 2). Sheet 131
ML17221A769
Person / Time
Site: Saint Lucie 
Issue date: 12/22/1987
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A769 (1)
Safety Injection Piping.
ML17221A768
Person / Time
Site: Saint Lucie 
Issue date: 06/10/1983
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A768 (1)
Safety Injection Piping.
ML17221A767
Person / Time
Site: Saint Lucie 
Issue date: 07/19/1984
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A767 (1)
Containment Spray.
ML17221A766
Person / Time
Site: Saint Lucie 
Issue date: 08/08/1983
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A766 (1)
Containment Spray.
ML17221A765
Person / Time
Site: Saint Lucie 
Issue date: 04/10/1983
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A765 (1)
START-UP System Auxiliary Feedwater No 17 Process System Feedwater No 9.
ML17221A764
Person / Time
Site: Saint Lucie 
Issue date: 04/08/1983
From:
EBASCO SERVICES, INC.
To:
FLORIDA POWER & LIGHT CO.
References
Download: ML17221A764 (1)
Responds to NRC 880405 Second Request for Addl Info Re ASME Code Relief Requests for safety-related pumps.W/21 Oversize Drawings
ML17221A762
Person / Time
Site: Saint Lucie 
Issue date: 05/12/1988
From: Conway W
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
Download: ML17221A762 (6)