MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2022-068, NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 22022-04-25025 April 2022 NextEra Energy Duane Arnold Quality Assurance Topical Report (FPL-3) Revision 2 L-2022-012, Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3)2022-03-16016 March 2022 Florida Power & Light Company Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2021-161, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2021-08-24024 August 2021 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2020-154, CFR 140.21 Licensee Guarantees of Payment of Deferred Preminms2020-11-12012 November 2020 CFR 140.21 Licensee Guarantees of Payment of Deferred Preminms L-2020-041, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2020-04-14014 April 2020 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2020-040, Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2020-03-11011 March 2020 Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2020-004, Mock Adversary Force2020-01-13013 January 2020 Mock Adversary Force L-2019-216, Proposed Turkey Point Units 6 and 7; Seabrook Station; Duane Arnold Energy Center; and Point Beach Units 1 and 2 - Re-issuance of Official Service List2019-12-19019 December 2019 Proposed Turkey Point Units 6 and 7; Seabrook Station; Duane Arnold Energy Center; and Point Beach Units 1 and 2 - Re-issuance of Official Service List L-2019-155, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events2019-11-21021 November 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events L-2019-202, CFR 50.46 - Emergency Core Cooling System LOCA 30-Day Report2019-11-19019 November 2019 CFR 50.46 - Emergency Core Cooling System LOCA 30-Day Report L-2019-182, Duane Arnold, and Point Beach Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2019-10-22022 October 2019 Duane Arnold, and Point Beach Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2019-161, License Amendment Request (TSCR-186): Removal of License Condition 2.C.(3), Fire Protection Program2019-09-25025 September 2019 License Amendment Request (TSCR-186): Removal of License Condition 2.C.(3), Fire Protection Program L-2019-157, Supplement to License Amendment Request (TSCR-183): Application to Revise Technical Specifications for the Permanently Defueled Condition2019-09-12012 September 2019 Supplement to License Amendment Request (TSCR-183): Application to Revise Technical Specifications for the Permanently Defueled Condition L-2019-133, Duane Arnold Energy Center and Point Beach, Units 1 & 2 -10 CFR Part 95 Facility Security Clearances2019-08-19019 August 2019 Duane Arnold Energy Center and Point Beach, Units 1 & 2 -10 CFR Part 95 Facility Security Clearances L-2019-141, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation. L-2019-142, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions. L-2019-146, Official Service List Update2019-07-22022 July 2019 Official Service List Update L-2019-134, Units 1 and 2 - Quality Assurance Topical Report, Revision 22, Annual Submittal2019-07-12012 July 2019 Units 1 and 2 - Quality Assurance Topical Report, Revision 22, Annual Submittal L-2019-105, License Amendment Request (TSCR-183): Application to Revise Operating License and Technical Specifications for Permanently Defueled Condition2019-06-20020 June 2019 License Amendment Request (TSCR-183): Application to Revise Operating License and Technical Specifications for Permanently Defueled Condition L-2019-093, Duane Arnold Energy Center and Point Beach, Units 1 & 2 - Official Service List Update2019-04-25025 April 2019 Duane Arnold Energy Center and Point Beach, Units 1 & 2 - Official Service List Update L-2019-050, License Amendment Request (TSCR-181): Application to Align Technical Specification Staffing and Administrative Requirements for Permanently Defueled Condition2019-04-19019 April 2019 License Amendment Request (TSCR-181): Application to Align Technical Specification Staffing and Administrative Requirements for Permanently Defueled Condition L-2019-070, License Amendment Request (TSCR-182): Proposed Changes to the Emergency Plan for Permanently Defueled Condition2019-04-0909 April 2019 License Amendment Request (TSCR-182): Proposed Changes to the Emergency Plan for Permanently Defueled Condition L-2019-045, NextEra Energy Duane Arnold, Ilc - Independent Spent Fuel Storage Installation (ISFSI) - Decommissioning Funding Status Reports, Financial Assurance Update2019-03-25025 March 2019 NextEra Energy Duane Arnold, Ilc - Independent Spent Fuel Storage Installation (ISFSI) - Decommissioning Funding Status Reports, Financial Assurance Update L-2019-057, Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2019-03-19019 March 2019 Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2019-052, Florida Power and Light Co. - Nuclear Property Insurance - 10 CFR 50.54(w)(3)2019-03-18018 March 2019 Florida Power and Light Co. - Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2019-047, Request for Exemption from 10 CFR 73.55(p)(1)(i) and (II) Related to the Suspension of Security Measures in an Emergency or During Severe Weather2019-02-28028 February 2019 Request for Exemption from 10 CFR 73.55(p)(1)(i) and (II) Related to the Suspension of Security Measures in an Emergency or During Severe Weather L-2019-009, Certification of Permanent Cessation of Power Operations2019-01-18018 January 2019 Certification of Permanent Cessation of Power Operations L-2018-214, Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2018-12-0303 December 2018 Units 1 and 2, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2018-068, Florida Power and Light Co. - Response to Request for Additional Information Re Decommissioning Funding Plan Updates for Independent Spent Fuel Storage Installations2018-04-0303 April 2018 Florida Power and Light Co. - Response to Request for Additional Information Re Decommissioning Funding Plan Updates for Independent Spent Fuel Storage Installations L-2018-060, Florida Power & Light: Nuclear Property Insurance - 10 CFR 50.54(w)(3)2018-03-26026 March 2018 Florida Power & Light: Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2018-063, CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications2018-03-26026 March 2018 CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications L-2018-067, Units 1 and 2 - Submittal of Joint Plant Access Shared Information Table2018-03-19019 March 2018 Units 1 and 2 - Submittal of Joint Plant Access Shared Information Table L-2018-030, Nuclear Energy Institute Commitments2018-03-0909 March 2018 Nuclear Energy Institute Commitments L-2018-064, NextEra Energy-Entergy Joint Composite Adversary Force2018-03-0808 March 2018 NextEra Energy-Entergy Joint Composite Adversary Force L-2017-212, Anchor Darling Double Disc Gate Valve Information and Status2017-12-21021 December 2017 Anchor Darling Double Disc Gate Valve Information and Status L-2017-200, 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2017-12-13013 December 2017 10 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2017-145, CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature2017-08-28028 August 2017 CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature L-2017-121, Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography2017-07-24024 July 2017 Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography L-2017-118, Submittal of 10 CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature2017-06-28028 June 2017 Submittal of 10 CFR 50.46 30-Day Special Report of Changes in Peak Cladding Temperature L-2017-122, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 21 Annual Submittal2017-06-28028 June 2017 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 21 Annual Submittal L-2017-095, Official Service List Changes2017-06-26026 June 2017 Official Service List Changes L-2017-104, Submittal of Report Pursuant to 10 CFR 71.95(a)(3) and (B) - Failure to Follow Conditions of TN-RAM Packaging Certificate of Compliance No. 92332017-06-15015 June 2017 Submittal of Report Pursuant to 10 CFR 71.95(a)(3) and (B) - Failure to Follow Conditions of TN-RAM Packaging Certificate of Compliance No. 9233 L-2017-014, Florida Power & Light Company - 10 CPR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications for 20162017-04-17017 April 2017 Florida Power & Light Company - 10 CPR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications for 2016 L-2017-040, Decommissioning Funding Status Reports/Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2017-03-30030 March 2017 Decommissioning Funding Status Reports/Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2017-051, Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2017-03-27027 March 2017 Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2016-216, Duane Arnold Energy Ctr., Point Beach Units 1 & 2, License Guarantees Payment of Deferred Premiums2016-12-0202 December 2016 Duane Arnold Energy Ctr., Point Beach Units 1 & 2, License Guarantees Payment of Deferred Premiums L-2016-188, Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools, Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f)2016-11-0303 November 2016 Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools, Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) L-2016-175, Units 1 and 2, Official Service List Changes and Distribution for Safeguards Information2016-08-30030 August 2016 Units 1 and 2, Official Service List Changes and Distribution for Safeguards Information 2024-01-25
[Table view] Category:Order Modifying License
MONTHYEARL-2019-155, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events2019-11-21021 November 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Beyond-Design Basis External Events L-2019-142, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions. L-2019-141, NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation.2019-08-0808 August 2019 NextEra Energy Duane Arnold, Llc'S Request for Rescission of Commission Order EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation. NG-16-0120, FLEX Strategies Phase 2 Staffing Assessment2016-06-0303 June 2016 FLEX Strategies Phase 2 Staffing Assessment NG-15-0260, NextEra Energy Duane Arnold Energy Center, Llc'S Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events...2015-08-14014 August 2015 NextEra Energy Duane Arnold Energy Center, Llc'S Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events... ML12054A6942012-03-12012 March 2012 Issuance of Order to Modify Licenses with Regard to Reliable Hardened Containment Vents ML12054A6792012-03-12012 March 2012 Issuance of Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation ML12056A0452012-03-12012 March 2012 Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events ML12056A0442012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status ML12056A0432012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark II Containments ML12054A7352012-03-12012 March 2012 Issuance of Order to Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events NRC-2012-0068, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events2012-03-12012 March 2012 Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events NRC-2012-0067, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status2012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status NRC-2012-0069, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark Ii Containments2012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Hardened Containment Vents - to All Operating Boiling Water Reactor Licensees with Mark I and Mark Ii Containments ML0616000762006-06-20020 June 2006 FRN: General Notice, EA-06-137 Enclosure, Order Modifying Licenses (Effective Immediately) ML0300603602003-01-0707 January 2003 Issuance of Order for Compensatory Measures Related to Access Authorization ML0228700082002-10-16016 October 2002 Enclosures 1 & 2, Order for Interim Safeguards & Compensatory Measures for Dry Independent Spent Fuel Storage Installation & Regulatory Issuance Summary 2002-12D 2019-08-08
[Table view] |
Text
NEXTera.
ENERGY~
DUANE ARNOLD November 21, 2019 NG-19-0105 L-2019-155 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Duane Arnold Energy Center Docket No. 50-331 Renewed Facility Operating License No. DPR-49 NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events"
References:
- 1. Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events," dated March 12, 2012(ML12054A735)
- 2. NextEra Energy Duane Arnold, LLC, "Certification of Permanent Cessation of Power Operations," dated January 18, 2019 (ML19023A196)
On March 12, 2012, the Nuclear Regulatory Commission (NRG) issued Order EA 049 (Reference 1) to NextEra Energy Duane Arnold, LLC (NEDA). A discussion of NEDA's implementation of the Order is included in the Enclosure.
By letter dated January 18, 2019 (Reference 2), NEDA provided formal notification to the NRG pursuant to 10 CFR 50.82(a)(1 )(i) and 10 CFR 50.4(b )(8) of the intention to permanently cease power operations at the DAEC in the fourth quarter of 2020.
The purpose of this letter is to request relief from certain provisions of Order EA-12-049 upon docketing of the 10 CFR 50.82(a)(1) certifications of permanent cessations of operation and permanent removal of fuel from the reactor vessel, and to request rescission of the Order effective at the end of a 90-day period following permanent shutdown. The enclosure to this letter provides the good cause justification for this request.
NextEra Energy Duane Arnold, LLC, 3277 DAEC Road, Palo, IA 52324
Document Control Desk NG-19-0105 Page 2 of 2 This letter contains no new regulatory commitments. If you have any questions regarding this submittal, please contact Michael Davis, Licensing Manager at 319-851-7032.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on November 1:_L, 2019.
Dean Curtland Site Director, Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC Enclosure cc: Director, Office of Nuclear Reactor Regulation USNRC Regional Administrator Region Ill USN RC Project Manager, Duane Arnold Energy Center USN RC Resident Inspector, Duane Arnold Energy Center
Enclosure to NG-19-0105 NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events" 4 pages follow
Enclosure to NG-19-0105 - NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events" 1 Request for Order Rescission NextEra Energy Duane Arnold, LLC (NEDA) hereby submits a request for relief from certain provisions of U.S. Nuclear Regulatory Commission (NRC) Order EA-12-049, "Order Modifying Licensees with Regard to Requirements for Beyond-Design-Basis External Events," upon docketing of the Title 10 Code of Federal Regulations (CFR) 50.82(a)(1) certifications for permanent cessation of operation and permanent removal of fuel from the reactor vessel. NEDA also hereby requests rescission of Order EA-12-049 effective at the end of a 90-day period following docketing of the certifications described above.
2 Background
On March 12, 2012, the NRC issued Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events," (Reference
- 1) to all licensees that operate boiling-water reactors with Mark I or Mark 11 containment designs. The Order was effective immediately and is applicable to the Duane Arnold Energy Center (DAEC). The Order required NEDA to install hardened containment venting systems that can be maintained functional during severe accident conditions (i.e., following significant core damage) and included two separate implementation phases. Phase 1 included modifications to wetwell venting systems, while Phase 2 included modifications to drywell venting systems or implementation of a reliable containment strategy that met regulatory approval.
By letter dated December 7, 2016 (Reference 2), NEDA notified the NRC, as required by Item IV.C.3 of Order EA-12-049, that full compliance with the requirements of the Order, for Phases 1 and 2, had been achieved for the DAEC. In Reference 3, the NRC provided the results of their review of the strategies and equipment provided to maintain or restore core cooling, SFP cooling, and containment following a Beyond-Design-Basis External Event (BDBEE) at DAEC and concluded that the design adequately addressed the requirements of Order EA-12-049.
By letter dated January 18, 2019 (Reference 4 ), NEDA provided formal notification to the NRC pursuant to 10 CFR 50.82(a)(1)(i) and 10 CFR 50.4(b)(8) of the intention to permanently cease power operations at the DAEC in the fourth quarter of 2020.
Consequently, NEDA requests relief from the requirements of NRC Order EA 049 for strategies and equipment provided to maintain or restore core cooling and containment following a BDBEE upon docketing of the Title 10 Code of Federal Regulations (CFR) 50.82(a)(1) certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel, and to rescind Order EA 049, in its entirety, effective at the end of the 90-day period following permanent shutdown.
1
Enclosure to NG-19-0105 - NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events" Order EA-13-109,Section IV, states that the Director, Office of Nuclear Reactor Regulation may, in writing, relax or rescind any of the above conditions upon demonstration by the Licensee of good cause.
3 Basis for Rescission Request Section Ill of Order EA-12-049 states that the Commission determined that all power reactor licensees and construction permit holders must develop, implement and maintain guidance and strategies to restore or maintain core cooling, containment, and SFP cooling capabilities in the event of a BDBEE. This statement forms the basis for the order and reflects the need to effectively deploy limited resources to mitigate very low frequency events with the potential to challenge both the reactor and SFP.
Core Cooling and Containment Requirements As noted in Reference 4, the DAEC will permanently cease operations in the fourth quarter of 2020; all fuel in the DAEC reactor will be relocated to the SFP shortly thereafter. The lack of fuel in the reactor vessel and the resulting absence of challenges to the primary containment render the need to maintain and restore core cooling and primary containment capabilities unnecessary. Upon permanent shutdown and defueling, primary containment will have no design function regarding protection of the fuel in the SFP or mitigation of SFP accident scenarios. This forms the basis for NEDA's request for relief from the requirements of Order EA-12-049 related to core cooling and containment strategies docketing of the 10 CFR 50.82(a)(1) certifications.
Spent Fuel Pool Requirements The SFP cooling requirements of Order EA-12-049 will continue to apply to DAEC until such time the fuel has sufficiently decayed, as discussed below.
NEDA has determined that for a loss of SFP cooling with no makeup capabilities, the total time to boil the SFP and to reduce SFP water inventory to a point 10 feet above the top of the highest point of the fuel assembly is calculated to be 67.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> (2.8 days) total. The 2.8-day period is based on the expected decay heat load following a 90-day period following reactor shutdown.
This result is based on a full core offload into the SFP and only credits the SFP water inventory. The decay heat load required to heat up and boil off the SFP water inventory is conservatively demonstrated via formal calculation and retained by DAEC. As such, reliance on SFP inventory for passive cooling provides an equivalent level of protection as would be provided by the initial phase of the guidance and strategies for maintaining or restoring SFP cooling per the Order.
Further, the low decay heat and long time to boil off the inventory to a point at which makeup would be necessary for radiation shielding purposes, obviate the need for transition phase guidance and strategies using onsite portable equipment per the Order. Lastly, the low decay heat and long time to boil off the inventory also provides 2
Enclosure to NG-19-0105 - NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events" sufficient time for DAEC to sustain the SFP cooling function indefinitely, obviating the need for the final phase of guidance and strategies per Order EA-12-049.
Once NEDA has docketed the 10 CFR 50.82(a)(1) certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel, the safety of the fuel in the SFP becomes the primary safety function for facility personnel. In the event of a challenge to the safety of fuel stored in the SFP, facility personnel would not be required to prioritize actions and the focus of the staff would be the SFP condition. Thus, the basis for the Order will no longer apply to the permanently shut down and defueled DAEC facility.
NEDA has performed an evaluation demonstrating that, 90 days after permanent shutdown, adequate time and water resources will be available to restore spent fuel pool cooling to maintain spent fuel pool water level 10 feet above the top of the spent fuel and the low decay heat and long time to boil off inventory provides sufficient time for DAEC to sustain the SFP cooling function indefinitely. Specifically, DAEC's standard portable fire pumps deliver adequate head and flow to provide the minimum required makeup to the SFP. The evaluation indicates this equipment can be installed in approximately 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to deliver SFP makeup. The required equipment and installation procedures are required to be maintained per DAEC Operating License section 2.C.(9), "Mitigation Strategy License Condition," item (b)(7).
Based on the above, the requirements of Order EA-12-049 should be rescinded 90 days after docketing of the 10 CFR 50.82(a)(1) certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel.
The proposed request is similar to those approved by the NRG for the permanently shut down and defueled Kewaunee Power Stations (ML14059A411 ), Vermont Yankee Nuclear Power Station (ML14321A685), Fort Calhoun Station Unit 1 (ML17124A114), and Pilgrim Nuclear Power Station (ML19094A632).
4 Conclusion Upon docketing of the 10 CFR 50.82(a)(1) certifications of permanent cessation of operations and permanent removal of fuel from the reactor vessel, the 10 CFR Part 50 license will no longer authorize operation of the reactor or emplacement or retention of fuel in the reactor vessel. Consequently, all fuel in the reactor will be relocated to the SFP. The lack of fuel in the reactor vessel and the resulting absence of challenges to the primary containment render the need to maintain or restore core cooling and primary containment capabilities unnecessary. SFP cooling guidance and strategies will be maintained until decay heat load from spent fuel has sufficiently decreased as previously described. Thus, the basis for the Order will no longer apply to the configuration of DAEC. NEDA has demonstrated good cause to support the request for relief from the Order requirements for guidance and strategies to maintain or restore core cooling and primary containment capabilities upon docketing of the 10 CFR 50.82(a)(1) certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel, and to support 3
Enclosure to NG-19-0105 - NextEra Energy Duane Arnold, LLC's Request for Rescission of Commission Order EA-12-049, "Order Modifying Licenses with Regard to Requirements for Beyond-Design-Basis External Events" NEDA's request that the Order be rescinded, in its entirety, effective at the end of the 90-day period following permanent shutdown.
Based on the above, the Director, Office of Nuclear Reactor Regulation (NRR) is requested to grant relief from the requirements of Order EA-12-049, for strategies and equipment provided to maintain and restore core cooling and containment following a BDBEE, upon docketing of the 10 CFR 50.82(a)(1) certifications for permanent cessation of operations and permanent removal of fuel from the reactor vessel, and to rescind Order EA-12-049, in its entirety, effective at the end of the 90-day period following permanent shutdown.
5 References
- 1. NRC Order Number EA-12-049, "Order Modifying Licenses with Regard to Requirements for Mitigating Strategies for Beyond-Design-Basis External Events," dated March 12, 2012(ML12054A735)
- 2. NextEra Energy Duane Arnold, LLC, "Notification of Full Compliance with Order EA-12-049 Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events and Submittal of Final Integrated Plan," dated December 7, 2016(ML16347A010)
- 3. NRC letter, "Duane Arnold Energy Center - Safety Evaluation Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-049 and EA-12-051," dated May 26, 2017(ML17129A037)
- 4. NextEra Energy Duane Arnold, LLC, "Certification of Permanent Cessation of Power Operations," dated January 18, 2019 (ML19023A196).
4